3/0 AWG 3C HVTECK Copper 140 mil TRXLPE TS AIA 8kV 133% IL Orange PVC Jacket CSA
Where are we? 4 Continents 9 Countries

Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Quick Support
3/0 AWG 3C HVTECK Copper 140 mil TRXLPE TS AIA 8kV 133% IL Orange PVC Jacket CSA
Application:
The 8kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications. Rated FT4, -40°C, Hazardous Locations (HL). These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lbs /FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids and are flame retardant.3 Conductor, 140 Mils Tree Retardant Cross Linked Polyethylene, 133% Insulation Level, Tape Shield, Polyvinyl Chloride (PVC) Inner Jacket, Aluminum Interlocked Armour (AIA), Polyvinyl Chloride (PVC) Jacket.
Also Known as:
3/0 AWG 3C 8kV HVTECK Cable, 3/0 AWG 3C 8kV 3/C Armored Power Cable, 3/0 AWG 3C 8kV Medium Voltage Teck Cable, 3/0-3C 8kV Copper Shielded Armored Cable, 3/0-3C 8kV 3-Core TR-XLPE AIA Cable.
Constructions:
Conductor: Class B compressed stranded bare copper per ASTM B3 and ASTM B8
Conductor Shield: Semi-conducting cross-linked copolymer
Insulation: 140 Mils Tree Retardant Cross Linked Polyethylene 133% insulation level
Insulation Shield: Strippable semi-conducting cross-linked copolymer
Copper Tape Shield: Helically wrapped 5 mil copper tape with 25% overlap
Filler: Interstices filled with non-hydroscoping/non-wicking fillers
Grounding Conductor: Class B compressed stranded bare copper ground per ASTM B3 and ASTM B8
Binder: Polypropylene tape
Inner Jacket: PVC inner jacket
Armour: Aluminum Interlocked Armour (AIA)
Overall Jacket: Orange Polyvinyl Chloride (PVC) Jacket.
Standards:
ASTM B3 Soft or Annealed Copper Wire
ASTM B8 Concentric-Lay-Stranded Copper Conductors
CSA C22.2 No. 174 Cables in Hazardous Locations
CSA C22.2 No. 2556 & No. 0.3 Wire and Cable Test Methods
CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV
CSA C68.3 Shielded & Concentric Neutral Power Cable - 5 to 46 kV
CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating
CSA HL - for Hazardous Locations rating
CSA SUN RES - for Sunlight Resistant rating
ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
ICEA T-29-520 Flame Test (210,000 BTU/Hr)
IEEE 383 Flame Test (70,000 btu)
IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test (1/0 and Larger)
IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test
FT1 Flame Test (1,706 BTU/Hr nominal - Vertical Wire Flame Test)
AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements).
Specifications:
Conductor Size: 3/0 AWG
Strand: 19
Diameter Over Conductor: 0.456 inch
Diameter Over Insulation: 0.774 inch
Insulation Thickness: 140 mil
Diameter Over Insulation Shield: 0.834 inch
Ground Size: 4 AWG
Inner Jacket Thickness: 110 mil
Dia.Over Armour: 2.421 inch
Overall Jacket Thickness: 75 mil
Approx.OD: 2.571inch
Copper Weight(lb/1000ft): 1747
Approx.Weight(lb/1000ft): 3825
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460
Garrie AI: Your Cable Guide