{"title":"HVTECK Aluminum 3\/C 140 mil TRXLPE TS AIA 8kV 133% IL Black PVC Jacket CSA","description":null,"products":[{"product_id":"2-awg-3c-hvteck-aluminum-140-mil-trxlpe-ts-aia-8kv-133-il-black-pvc-jacket-csa","title":"2 AWG 3C HVTECK Aluminum 140 mil TRXLPE TS AIA 8kV 133% IL Black PVC Jacket CSA","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC26272_1.pdf?v=1791454524\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e2 AWG 3C HVTECK Aluminum 140 mil TRXLPE TS AIA 8kV 133% IL Black PVC Jacket CSA\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan data-sheets-root=\"1\"\u003eApplication:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan data-sheets-root=\"1\"\u003eThe 8kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications. Rated FT4, -40°C, Hazardous Locations (HL). These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lbs \/FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids and are flame retardant.3 Conductor, 140 Mils Tree Retardant Cross Linked Polyethylene, 133% Insulation Level, Tape Shield, Polyvinyl Chloride (PVC) Inner Jacket, Aluminum Interlocked Armour (AIA), Polyvinyl Chloride (PVC) Jacket.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eAlso Known As:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"mso-spacerun: yes;\"\u003e 2 AWG 3C \u003c\/span\u003e8kV Aluminum HVTECK Cable, \u003cspan style=\"mso-spacerun: yes;\"\u003e2 AWG 3C \u003c\/span\u003e8kV 3\/C Aluminum Armored Power Cable, \u003cspan style=\"mso-spacerun: yes;\"\u003e2 AWG 3C \u003c\/span\u003e8kV Medium Voltage Teck Cable, 2-3C 8kV Aluminum Shielded Armored Cable, 2-3C 8kV 3-Core TR-XLPE AIA Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eConstructions:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cstrong\u003e Conductor:\u003c\/strong\u003e Class B compact stranded 8000 Series aluminum per ASTM B800 and ASTM B836\u003cbr\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi-conducting cross-linked copolymer; A conductor separator is used for cable size     larger than or equal to 500 Kcmil\u003cbr\u003e\u003cstrong\u003e Insulation:\u003c\/strong\u003e 140 Mils Tree Retardant Cross Linked Polyethylene 133% insulation level\u003cbr\u003e\u003cstrong\u003e Insulation Shield:\u003c\/strong\u003e Strippable semi-conducting cross-linked copolymer\u003cbr\u003e \u003cstrong\u003eCopper Tape Shield:\u003c\/strong\u003e Helically wrapped 5 mil copper tape with 25% overlap\u003cbr\u003e \u003cstrong\u003eFiller:\u003c\/strong\u003e Interstices filled with non-hydroscoping\/non-wicking fillers\u003cbr\u003e \u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e Class B compressed stranded bare copper ground per ASTM B3 and ASTM B8\u003cbr\u003e \u003cstrong\u003eBinder:\u003c\/strong\u003e Polypropylene tape\u003cbr\u003e \u003cstrong\u003eInner Jacket:\u003c\/strong\u003e PVC inner jacket\u003cbr\u003e\u003cstrong\u003e Armour:\u003c\/strong\u003e Aluminum Interlocked Armour (AIA)\u003cbr\u003e \u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e Black Polyvinyl Chloride (PVC) Jacket.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eStandards:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan data-sheets-root=\"1\"\u003e ASTM B801 Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy\u003cbr\u003e ASTM B836 Compact Rounded Stranded Aluminum Conductors\u003cbr\u003e CSA C22.2 No. 174 Cables in Hazardous Locations\u003cbr\u003e CSA C22.2 No. 2556 \u0026amp; No. 0.3 Wire and Cable Test Methods\u003cbr\u003e CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV\u003cbr\u003e CSA C68.3 Shielded \u0026amp; Concentric Neutral Power Cable - 5 to 46 kV\u003cbr\u003e CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating\u003cbr\u003e CSA HL - for Hazardous Locations rating\u003cbr\u003e CSA SUN RES - for Sunlight Resistant rating\u003cbr\u003e ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable\u003cbr\u003e ICEA T-29-520 Flame Test (210,000 BTU\/Hr)\u003cbr\u003e IEEE 383 Flame Test (70,000 btu)\u003cbr\u003e IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test (1\/0 and Larger)\u003cbr\u003e IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003cbr\u003e FT1 Flame Test (1,706 BTU\/Hr nominal - Vertical Wire Flame Test)\u003cbr\u003e AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test \u003c\/span\u003e\u003cspan data-sheets-root=\"1\"\u003eRequirements).\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan data-sheets-root=\"1\"\u003eSpecification:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eConductor Size: \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e2 AWG\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cbr\u003eStrand: \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e8\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cbr\u003eDiameter Over Conductor: \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e0.268 inch\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cbr\u003eDiameter Over Insulation: \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e0.586 inch\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cbr\u003eInsulation Thickness:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e 140 mil\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eDiameter Over Insulation Shield: \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e0.646 inch\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cbr\u003eGround Size: \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e8 AWG\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cbr\u003eInner Jacket Thickness: \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e80 mil\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cbr\u003eDia. Over Armour: \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e1.949 inch\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cbr\u003eOverall Jacket Thickness:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e 60 mil\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cbr\u003eApprox.OD: \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e2.069 inch\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cbr\u003eCopper Weight(lb\/1000ft): \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e223\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cbr\u003eApprox.Weight(lb\/1000ft): \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e1726\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"width: 325.114px; height: 35.5966px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e 673689\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":67663513780593,"sku":"NNC673689","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitleddesign_7_b630174a-66a1-4f3c-a183-b7509013e338.png?v=1791454828"},{"product_id":"1-awg-3c-hvteck-aluminum-140-mil-trxlpe-ts-aia-8kv-133-il-black-pvc-jacket-csa","title":"1 AWG 3C HVTECK Aluminum 140 mil TRXLPE TS AIA 8kV 133% IL Black PVC Jacket CSA","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC26272_1.pdf?v=1791454524\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e1 AWG 3C HVTECK Aluminum 140 mil TRXLPE TS AIA 8kV 133% IL Black PVC Jacket CSA\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan data-sheets-root=\"1\"\u003eApplication:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan data-sheets-root=\"1\"\u003eThe 8kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications. Rated FT4, -40°C, Hazardous Locations (HL). These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lbs \/FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids and are flame retardant.3 Conductor, 140 Mils Tree Retardant Cross Linked Polyethylene, 133% Insulation Level, Tape Shield, Polyvinyl Chloride (PVC) Inner Jacket, Aluminum Interlocked Armour (AIA), Polyvinyl Chloride (PVC) Jacket.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eAlso Known As:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"mso-spacerun: yes;\"\u003e 1 AWG 3C \u003c\/span\u003e8kV Aluminum HVTECK Cable, 1\u003cspan style=\"mso-spacerun: yes;\"\u003e AWG 3C \u003c\/span\u003e8kV 3\/C Aluminum Armored Power Cable, 1\u003cspan style=\"mso-spacerun: yes;\"\u003e AWG 3C \u003c\/span\u003e8kV Medium Voltage Teck Cable, 1-3C 8kV Aluminum Shielded Armored Cable, 1-3C 8kV 3-Core TR-XLPE AIA Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eConstructions:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cstrong\u003e Conductor:\u003c\/strong\u003e Class B compact stranded 8000 Series aluminum per ASTM B800 and ASTM B836\u003cbr\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi-conducting cross-linked copolymer; A conductor separator is used for cable size     larger than or equal to 500 Kcmil\u003cbr\u003e\u003cstrong\u003e Insulation:\u003c\/strong\u003e 140 Mils Tree Retardant Cross Linked Polyethylene 133% insulation level\u003cbr\u003e\u003cstrong\u003e Insulation Shield:\u003c\/strong\u003e Strippable semi-conducting cross-linked copolymer\u003cbr\u003e \u003cstrong\u003eCopper Tape Shield:\u003c\/strong\u003e Helically wrapped 5 mil copper tape with 25% overlap\u003cbr\u003e \u003cstrong\u003eFiller:\u003c\/strong\u003e Interstices filled with non-hydroscoping\/non-wicking fillers\u003cbr\u003e \u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e Class B compressed stranded bare copper ground per ASTM B3 and ASTM B8\u003cbr\u003e \u003cstrong\u003eBinder:\u003c\/strong\u003e Polypropylene tape\u003cbr\u003e \u003cstrong\u003eInner Jacket:\u003c\/strong\u003e PVC inner jacket\u003cbr\u003e\u003cstrong\u003e Armour:\u003c\/strong\u003e Aluminum Interlocked Armour (AIA)\u003cbr\u003e \u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e Black Polyvinyl Chloride (PVC) Jacket.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eStandards:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan data-sheets-root=\"1\"\u003e ASTM B801 Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy\u003cbr\u003e ASTM B836 Compact Rounded Stranded Aluminum Conductors\u003cbr\u003e CSA C22.2 No. 174 Cables in Hazardous Locations\u003cbr\u003e CSA C22.2 No. 2556 \u0026amp; No. 0.3 Wire and Cable Test Methods\u003cbr\u003e CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV\u003cbr\u003e CSA C68.3 Shielded \u0026amp; Concentric Neutral Power Cable - 5 to 46 kV\u003cbr\u003e CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating\u003cbr\u003e CSA HL - for Hazardous Locations rating\u003cbr\u003e CSA SUN RES - for Sunlight Resistant rating\u003cbr\u003e ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable\u003cbr\u003e ICEA T-29-520 Flame Test (210,000 BTU\/Hr)\u003cbr\u003e IEEE 383 Flame Test (70,000 btu)\u003cbr\u003e IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test (1\/0 and Larger)\u003cbr\u003e IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003cbr\u003e FT1 Flame Test (1,706 BTU\/Hr nominal - Vertical Wire Flame Test)\u003cbr\u003e AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test \u003c\/span\u003e\u003cspan data-sheets-root=\"1\"\u003eRequirements).\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan data-sheets-root=\"1\"\u003eSpecification:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eConductor Size: \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e1 AWG\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cbr\u003eStrand: \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e19\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cbr\u003eDiameter Over Conductor: \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e0.298 inch\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cbr\u003eDiameter Over Insulation: \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e0.617inch\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cbr\u003eInsulation Thickness:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e 140 mil\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eDiameter Over Insulation Shield: \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e0.677\u003c\/span\u003e\u003cspan data-sheets-root=\"1\"\u003e inch\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cbr\u003eGround Size: \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e6 AWG\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cbr\u003eInner Jacket Thickness: \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e110 mil\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cbr\u003eDia. Over Armour: \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e2.076\u003c\/span\u003e\u003cspan data-sheets-root=\"1\"\u003e inch\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cbr\u003eOverall Jacket Thickness:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e 60 mil\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cbr\u003eApprox.OD:  \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e2.196 inch\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cbr\u003eCopper Weight(lb\/1000ft): \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e260\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cbr\u003eApprox.Weight(lb\/1000ft):  \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e1985\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"width: 325.114px; height: 35.5966px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e 652778\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":67663568503153,"sku":"NNC652778","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitleddesign_7_b630174a-66a1-4f3c-a183-b7509013e338.png?v=1791454828"}],"url":"https:\/\/nassaunationalcable.com\/en-ca\/collections\/hvteck-aluminum-3-c-140-mil-trxlpe-ts-aia-8kv-133-il-black-pvc-jacket-csa.oembed","provider":"NassauNationalCable","version":"1.0","type":"link"}