{"title":"HELUKABEL TRONIC (LiYY) PVC DATA CABLE","description":"","products":[{"product_id":"26-awg-2c-helukabel-18001-tronic-liyy-pvc-data-cable","title":"26 AWG 2C Helukabel 18001 TRONIC (LiYY) PVC data cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M18001_EN_GB_1.pdf?v=1764135724\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 2C Helukabel 18001 TRONIC (LiYY) PVC data cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. For use where design or constructional measures in the outer diameter require the smallest possible control and signal cables; machine, tool and plant construction, as well as in electronic engineering. Also used in computer systems, scales and in measurement and control technology.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 2C Helukabel Tronic LiYY cable, LiYY PVC data cable, Helukabel LiYY specs, Tronic LiYY cable price, Helukabel signal cable LiYY, 26 AWG 2C LiYY flexible control cable, Helukabel PVC data cable, LiYY multi-core cable, Helukabel LiYY datasheet, 26 AWG 2C LiYY low voltage cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003c\/strong\u003e\u003cbr\u003e0.14 mm²: 350 V\u003cbr\u003e0.25 - 1.5 mm²: 500 V\u003cbr\u003e(not for high power current installation purposes)\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 1200 V\u003cbr\u003e0.34 - 1.5 mm²: 2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 2400 V\u003cbr\u003e0.34 - 1.5 mm²: 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cbr\u003eat 800 Hz \u003cbr\u003e0.14 - 0.25 mm²: approx. 100 pF\/m\u003cbr\u003e0.34 - 1.5 mm²: approx. 150 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance \u003c\/strong\u003e\u003cbr\u003e78 Ohm,\u003cbr\u003e(approx. value)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003cbr\u003e\u003c\/strong\u003eapprox. 0.65 mH\/km\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 1.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification in alignment with DIN 47100, colour coded without colour repetition from the 45th core\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 26 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e\u003cspan\u003e 2 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 3.2 \u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e2.7\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e13.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62719716360561,"sku":"NNC18001","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_d10e6efb-1056-4955-93b1-0bbc91855463.png?v=1764137629"},{"product_id":"26-awg-3c-helukabel-18002-tronic-liyy-pvc-data-cable","title":"26 AWG 3C Helukabel 18002 TRONIC (LiYY) PVC data cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M18001_EN_GB_1.pdf?v=1764135724\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 3C Helukabel 18002 TRONIC (LiYY) PVC data cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. For use where design or constructional measures in the outer diameter require the smallest possible control and signal cables; machine, tool and plant construction, as well as in electronic engineering. Also used in computer systems, scales and in measurement and control technology.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 3C Helukabel Tronic LiYY cable, LiYY PVC data cable, Helukabel LiYY specs, Tronic LiYY cable price, Helukabel signal cable LiYY, 26 AWG 3C LiYY flexible control cable, Helukabel PVC data cable, LiYY multi-core cable, Helukabel LiYY datasheet, 26 AWG 3C LiYY low voltage cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003c\/strong\u003e\u003cbr\u003e0.14 mm²: 350 V\u003cbr\u003e0.25 - 1.5 mm²: 500 V\u003cbr\u003e(not for high power current installation purposes)\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 1200 V\u003cbr\u003e0.34 - 1.5 mm²: 2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 2400 V\u003cbr\u003e0.34 - 1.5 mm²: 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cbr\u003eat 800 Hz \u003cbr\u003e0.14 - 0.25 mm²: approx. 100 pF\/m\u003cbr\u003e0.34 - 1.5 mm²: approx. 150 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance \u003c\/strong\u003e\u003cbr\u003e78 Ohm,\u003cbr\u003e(approx. value)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003cbr\u003e\u003c\/strong\u003eapprox. 0.65 mH\/km\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 1.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification in alignment with DIN 47100, colour coded without colour repetition from the 45th core\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 26 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e\u003cspan\u003e 3 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 3.4\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e4.0 \u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e16.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62720095420785,"sku":"NNC18002","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_d10e6efb-1056-4955-93b1-0bbc91855463.png?v=1764137629"},{"product_id":"26-awg-4c-helukabel-18003-tronic-liyy-pvc-data-cable","title":"26 AWG 4C Helukabel 18003 TRONIC (LiYY) PVC data cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M18001_EN_GB_1.pdf?v=1764135724\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 4C Helukabel 18003 TRONIC (LiYY) PVC data cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. For use where design or constructional measures in the outer diameter require the smallest possible control and signal cables; machine, tool and plant construction, as well as in electronic engineering. Also used in computer systems, scales and in measurement and control technology.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 4C Helukabel Tronic LiYY cable, LiYY PVC data cable, Helukabel LiYY specs, Tronic LiYY cable price, Helukabel signal cable LiYY, 26 AWG 4C LiYY flexible control cable, Helukabel PVC data cable, LiYY multi-core cable, Helukabel LiYY datasheet, 26 AWG 4C LiYY low voltage cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003c\/strong\u003e\u003cbr\u003e0.14 mm²: 350 V\u003cbr\u003e0.25 - 1.5 mm²: 500 V\u003cbr\u003e(not for high power current installation purposes)\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 1200 V\u003cbr\u003e0.34 - 1.5 mm²: 2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 2400 V\u003cbr\u003e0.34 - 1.5 mm²: 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cbr\u003eat 800 Hz \u003cbr\u003e0.14 - 0.25 mm²: approx. 100 pF\/m\u003cbr\u003e0.34 - 1.5 mm²: approx. 150 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance \u003c\/strong\u003e\u003cbr\u003e78 Ohm,\u003cbr\u003e(approx. value)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003cbr\u003e\u003c\/strong\u003eapprox. 0.65 mH\/km\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 1.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification in alignment with DIN 47100, colour coded without colour repetition from the 45th core\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 26 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e\u003cspan\u003e 4 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 3.6\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e5.4\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e19.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62720156107121,"sku":"NNC18003","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_d10e6efb-1056-4955-93b1-0bbc91855463.png?v=1764137629"},{"product_id":"26-awg-5c-helukabel-18004-tronic-liyy-pvc-data-cable","title":"26 AWG 5C Helukabel 18004 TRONIC (LiYY) PVC data cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M18001_EN_GB_1.pdf?v=1764135724\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 5C Helukabel 18004 TRONIC (LiYY) PVC data cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. For use where design or constructional measures in the outer diameter require the smallest possible control and signal cables; machine, tool and plant construction, as well as in electronic engineering. Also used in computer systems, scales and in measurement and control technology.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 5C Helukabel Tronic LiYY cable, LiYY PVC data cable, Helukabel LiYY specs, Tronic LiYY cable price, Helukabel signal cable LiYY, 26 AWG 5C LiYY flexible control cable, Helukabel PVC data cable, LiYY multi-core cable, Helukabel LiYY datasheet, 26 AWG 5C LiYY low voltage cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003c\/strong\u003e\u003cbr\u003e0.14 mm²: 350 V\u003cbr\u003e0.25 - 1.5 mm²: 500 V\u003cbr\u003e(not for high power current installation purposes)\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 1200 V\u003cbr\u003e0.34 - 1.5 mm²: 2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 2400 V\u003cbr\u003e0.34 - 1.5 mm²: 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cbr\u003eat 800 Hz \u003cbr\u003e0.14 - 0.25 mm²: approx. 100 pF\/m\u003cbr\u003e0.34 - 1.5 mm²: approx. 150 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance \u003c\/strong\u003e\u003cbr\u003e78 Ohm,\u003cbr\u003e(approx. value)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003cbr\u003e\u003c\/strong\u003eapprox. 0.65 mH\/km\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 1.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification in alignment with DIN 47100, colour coded without colour repetition from the 45th core\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 26 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e\u003cspan\u003e 5 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 3.9\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e6.7\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e22.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62720248349041,"sku":"NNC18004","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_d10e6efb-1056-4955-93b1-0bbc91855463.png?v=1764137629"},{"product_id":"26-awg-6c-helukabel-18005-tronic-liyy-pvc-data-cable","title":"26 AWG 6C Helukabel 18005 TRONIC (LiYY) PVC data cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M18001_EN_GB_1.pdf?v=1764135724\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 6C Helukabel 18005 TRONIC (LiYY) PVC data cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. For use where design or constructional measures in the outer diameter require the smallest possible control and signal cables; machine, tool and plant construction, as well as in electronic engineering. Also used in computer systems, scales and in measurement and control technology.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 6C Helukabel Tronic LiYY cable, LiYY PVC data cable, Helukabel LiYY specs, Tronic LiYY cable price, Helukabel signal cable LiYY, 26 AWG 6C LiYY flexible control cable, Helukabel PVC data cable, LiYY multi-core cable, Helukabel LiYY datasheet, 26 AWG 6C LiYY low voltage cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003c\/strong\u003e\u003cbr\u003e0.14 mm²: 350 V\u003cbr\u003e0.25 - 1.5 mm²: 500 V\u003cbr\u003e(not for high power current installation purposes)\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 1200 V\u003cbr\u003e0.34 - 1.5 mm²: 2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 2400 V\u003cbr\u003e0.34 - 1.5 mm²: 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cbr\u003eat 800 Hz \u003cbr\u003e0.14 - 0.25 mm²: approx. 100 pF\/m\u003cbr\u003e0.34 - 1.5 mm²: approx. 150 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance \u003c\/strong\u003e\u003cbr\u003e78 Ohm,\u003cbr\u003e(approx. value)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003cbr\u003e\u003c\/strong\u003eapprox. 0.65 mH\/km\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 1.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification in alignment with DIN 47100, colour coded without colour repetition from the 45th core\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 26 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e\u003cspan\u003e 6 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 4.4\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e8.1 \u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e25.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62720672858481,"sku":"NNC18005","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_d10e6efb-1056-4955-93b1-0bbc91855463.png?v=1764137629"},{"product_id":"26-awg-7c-helukabel-18006-tronic-liyy-pvc-data-cable","title":"26 AWG 7C Helukabel 18006 TRONIC (LiYY) PVC data cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M18001_EN_GB_1.pdf?v=1764135724\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 7C Helukabel 18006 TRONIC (LiYY) PVC data cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. For use where design or constructional measures in the outer diameter require the smallest possible control and signal cables; machine, tool and plant construction, as well as in electronic engineering. Also used in computer systems, scales and in measurement and control technology.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 7C Helukabel Tronic LiYY cable, LiYY PVC data cable, Helukabel LiYY specs, Tronic LiYY cable price, Helukabel signal cable LiYY, 26 AWG 7C LiYY flexible control cable, Helukabel PVC data cable, LiYY multi-core cable, Helukabel LiYY datasheet, 26 AWG 7C LiYY low voltage cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003c\/strong\u003e\u003cbr\u003e0.14 mm²: 350 V\u003cbr\u003e0.25 - 1.5 mm²: 500 V\u003cbr\u003e(not for high power current installation purposes)\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 1200 V\u003cbr\u003e0.34 - 1.5 mm²: 2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 2400 V\u003cbr\u003e0.34 - 1.5 mm²: 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cbr\u003eat 800 Hz \u003cbr\u003e0.14 - 0.25 mm²: approx. 100 pF\/m\u003cbr\u003e0.34 - 1.5 mm²: approx. 150 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance \u003c\/strong\u003e\u003cbr\u003e78 Ohm,\u003cbr\u003e(approx. value)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003cbr\u003e\u003c\/strong\u003eapprox. 0.65 mH\/km\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 1.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification in alignment with DIN 47100, colour coded without colour repetition from the 45th core\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 26 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e\u003cspan\u003e 7 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 4.4\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e9.4\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e28.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62720738623857,"sku":"NNC18006","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_d10e6efb-1056-4955-93b1-0bbc91855463.png?v=1764137629"},{"product_id":"26-awg-8c-helukabel-18007-tronic-liyy-pvc-data-cable","title":"26 AWG 8C Helukabel 18007 TRONIC (LiYY) PVC data cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M18001_EN_GB_1.pdf?v=1764135724\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 8C Helukabel 18007 TRONIC (LiYY) PVC data cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. For use where design or constructional measures in the outer diameter require the smallest possible control and signal cables; machine, tool and plant construction, as well as in electronic engineering. Also used in computer systems, scales and in measurement and control technology.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 8C Helukabel Tronic LiYY cable, LiYY PVC data cable, Helukabel LiYY specs, Tronic LiYY cable price, Helukabel signal cable LiYY, 26 AWG 8C LiYY flexible control cable, Helukabel PVC data cable, LiYY multi-core cable, Helukabel LiYY datasheet, 26 AWG 8C LiYY low voltage cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003c\/strong\u003e\u003cbr\u003e0.14 mm²: 350 V\u003cbr\u003e0.25 - 1.5 mm²: 500 V\u003cbr\u003e(not for high power current installation purposes)\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 1200 V\u003cbr\u003e0.34 - 1.5 mm²: 2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 2400 V\u003cbr\u003e0.34 - 1.5 mm²: 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cbr\u003eat 800 Hz \u003cbr\u003e0.14 - 0.25 mm²: approx. 100 pF\/m\u003cbr\u003e0.34 - 1.5 mm²: approx. 150 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance \u003c\/strong\u003e\u003cbr\u003e78 Ohm,\u003cbr\u003e(approx. value)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003cbr\u003e\u003c\/strong\u003eapprox. 0.65 mH\/km\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 1.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification in alignment with DIN 47100, colour coded without colour repetition from the 45th core\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 26 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e\u003cspan\u003e 8 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 5.0\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e10.7\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e35.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62720763822449,"sku":"NNC18007","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_d10e6efb-1056-4955-93b1-0bbc91855463.png?v=1764137629"},{"product_id":"26-awg-10c-helukabel-18008-tronic-liyy-pvc-data-cable","title":"26 AWG 10C Helukabel 18008 TRONIC (LiYY) PVC data cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M18001_EN_GB_1.pdf?v=1764135724\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 10C Helukabel 18008 TRONIC (LiYY) PVC data cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. For use where design or constructional measures in the outer diameter require the smallest possible control and signal cables; machine, tool and plant construction, as well as in electronic engineering. Also used in computer systems, scales and in measurement and control technology.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 10C Helukabel Tronic LiYY cable, LiYY PVC data cable, Helukabel LiYY specs, Tronic LiYY cable price, Helukabel signal cable LiYY, 26 AWG 10C LiYY flexible control cable, Helukabel PVC data cable, LiYY multi-core cable, Helukabel LiYY datasheet, 26 AWG 10C LiYY low voltage cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003c\/strong\u003e\u003cbr\u003e0.14 mm²: 350 V\u003cbr\u003e0.25 - 1.5 mm²: 500 V\u003cbr\u003e(not for high power current installation purposes)\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 1200 V\u003cbr\u003e0.34 - 1.5 mm²: 2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 2400 V\u003cbr\u003e0.34 - 1.5 mm²: 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cbr\u003eat 800 Hz \u003cbr\u003e0.14 - 0.25 mm²: approx. 100 pF\/m\u003cbr\u003e0.34 - 1.5 mm²: approx. 150 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance \u003c\/strong\u003e\u003cbr\u003e78 Ohm,\u003cbr\u003e(approx. value)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003cbr\u003e\u003c\/strong\u003eapprox. 0.65 mH\/km\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 1.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification in alignment with DIN 47100, colour coded without colour repetition from the 45th core\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 26 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e\u003cspan\u003e 10 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 5.4\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e13.4\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e41.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62721022919025,"sku":"NNC18008","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_d10e6efb-1056-4955-93b1-0bbc91855463.png?v=1764137629"},{"product_id":"26-awg-12c-helukabel-18009-tronic-liyy-pvc-data-cable","title":"26 AWG 12C Helukabel 18009 TRONIC (LiYY) PVC data cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M18001_EN_GB_1.pdf?v=1764135724\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 12C Helukabel 18009 TRONIC (LiYY) PVC data cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. For use where design or constructional measures in the outer diameter require the smallest possible control and signal cables; machine, tool and plant construction, as well as in electronic engineering. Also used in computer systems, scales and in measurement and control technology.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 12C Helukabel Tronic LiYY cable, LiYY PVC data cable, Helukabel LiYY specs, Tronic LiYY cable price, Helukabel signal cable LiYY, 26 AWG 12C LiYY flexible control cable, Helukabel PVC data cable, LiYY multi-core cable, Helukabel LiYY datasheet, 26 AWG 12C LiYY low voltage cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003c\/strong\u003e\u003cbr\u003e0.14 mm²: 350 V\u003cbr\u003e0.25 - 1.5 mm²: 500 V\u003cbr\u003e(not for high power current installation purposes)\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 1200 V\u003cbr\u003e0.34 - 1.5 mm²: 2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 2400 V\u003cbr\u003e0.34 - 1.5 mm²: 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cbr\u003eat 800 Hz \u003cbr\u003e0.14 - 0.25 mm²: approx. 100 pF\/m\u003cbr\u003e0.34 - 1.5 mm²: approx. 150 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance \u003c\/strong\u003e\u003cbr\u003e78 Ohm,\u003cbr\u003e(approx. value)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003cbr\u003e\u003c\/strong\u003eapprox. 0.65 mH\/km\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 1.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification in alignment with DIN 47100, colour coded without colour repetition from the 45th core\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 26 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e\u003cspan\u003e 12 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 5.6\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e16.1\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e48.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62721196491121,"sku":"NNC18009","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_d10e6efb-1056-4955-93b1-0bbc91855463.png?v=1764137629"},{"product_id":"26-awg-14c-helukabel-18010-tronic-liyy-pvc-data-cable","title":"26 AWG 14C Helukabel 18010 TRONIC (LiYY) PVC data cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M18001_EN_GB_1.pdf?v=1764135724\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 14C Helukabel 18010 TRONIC (LiYY) PVC data cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. For use where design or constructional measures in the outer diameter require the smallest possible control and signal cables; machine, tool and plant construction, as well as in electronic engineering. Also used in computer systems, scales and in measurement and control technology.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 14C Helukabel Tronic LiYY cable, LiYY PVC data cable, Helukabel LiYY specs, Tronic LiYY cable price, Helukabel signal cable LiYY, 26 AWG 14C LiYY flexible control cable, Helukabel PVC data cable, LiYY multi-core cable, Helukabel LiYY datasheet, 26 AWG 14C LiYY low voltage cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003c\/strong\u003e\u003cbr\u003e0.14 mm²: 350 V\u003cbr\u003e0.25 - 1.5 mm²: 500 V\u003cbr\u003e(not for high power current installation purposes)\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 1200 V\u003cbr\u003e0.34 - 1.5 mm²: 2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 2400 V\u003cbr\u003e0.34 - 1.5 mm²: 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cbr\u003eat 800 Hz \u003cbr\u003e0.14 - 0.25 mm²: approx. 100 pF\/m\u003cbr\u003e0.34 - 1.5 mm²: approx. 150 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance \u003c\/strong\u003e\u003cbr\u003e78 Ohm,\u003cbr\u003e(approx. value)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003cbr\u003e\u003c\/strong\u003eapprox. 0.65 mH\/km\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 1.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification in alignment with DIN 47100, colour coded without colour repetition from the 45th core\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 26 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e\u003cspan\u003e 14 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 6.0\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e18.8\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e53.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62721468268913,"sku":"NNC18010","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_d10e6efb-1056-4955-93b1-0bbc91855463.png?v=1764137629"},{"product_id":"26-awg-16c-helukabel-18011-tronic-liyy-pvc-data-cable","title":"26 AWG 16C Helukabel 18011 TRONIC (LiYY) PVC data cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M18001_EN_GB_1.pdf?v=1764135724\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 16C Helukabel 18011 TRONIC (LiYY) PVC data cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. For use where design or constructional measures in the outer diameter require the smallest possible control and signal cables; machine, tool and plant construction, as well as in electronic engineering. Also used in computer systems, scales and in measurement and control technology.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 16C Helukabel Tronic LiYY cable, LiYY PVC data cable, Helukabel LiYY specs, Tronic LiYY cable price, Helukabel signal cable LiYY, 26 AWG 16C LiYY flexible control cable, Helukabel PVC data cable, LiYY multi-core cable, Helukabel LiYY datasheet, 26 AWG 16C LiYY low voltage cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003c\/strong\u003e\u003cbr\u003e0.14 mm²: 350 V\u003cbr\u003e0.25 - 1.5 mm²: 500 V\u003cbr\u003e(not for high power current installation purposes)\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 1200 V\u003cbr\u003e0.34 - 1.5 mm²: 2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 2400 V\u003cbr\u003e0.34 - 1.5 mm²: 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cbr\u003eat 800 Hz \u003cbr\u003e0.14 - 0.25 mm²: approx. 100 pF\/m\u003cbr\u003e0.34 - 1.5 mm²: approx. 150 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance \u003c\/strong\u003e\u003cbr\u003e78 Ohm,\u003cbr\u003e(approx. value)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003cbr\u003e\u003c\/strong\u003eapprox. 0.65 mH\/km\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 1.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification in alignment with DIN 47100, colour coded without colour repetition from the 45th core\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 26 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e\u003cspan\u003e 16 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 6.3\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e21.5\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e59.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62721774780785,"sku":"NNC18011","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_d10e6efb-1056-4955-93b1-0bbc91855463.png?v=1764137629"},{"product_id":"26-awg-18c-helukabel-18012-tronic-liyy-pvc-data-cable","title":"26 AWG 18C Helukabel 18012 TRONIC (LiYY) PVC data cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M18001_EN_GB_1.pdf?v=1764135724\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 18C Helukabel 18012 TRONIC (LiYY) PVC data cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. For use where design or constructional measures in the outer diameter require the smallest possible control and signal cables; machine, tool and plant construction, as well as in electronic engineering. Also used in computer systems, scales and in measurement and control technology.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 18C Helukabel Tronic LiYY cable, LiYY PVC data cable, Helukabel LiYY specs, Tronic LiYY cable price, Helukabel signal cable LiYY, 26 AWG 18C LiYY flexible control cable, Helukabel PVC data cable, LiYY multi-core cable, Helukabel LiYY datasheet, 26 AWG 18C LiYY low voltage cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003c\/strong\u003e\u003cbr\u003e0.14 mm²: 350 V\u003cbr\u003e0.25 - 1.5 mm²: 500 V\u003cbr\u003e(not for high power current installation purposes)\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 1200 V\u003cbr\u003e0.34 - 1.5 mm²: 2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 2400 V\u003cbr\u003e0.34 - 1.5 mm²: 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cbr\u003eat 800 Hz \u003cbr\u003e0.14 - 0.25 mm²: approx. 100 pF\/m\u003cbr\u003e0.34 - 1.5 mm²: approx. 150 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance \u003c\/strong\u003e\u003cbr\u003e78 Ohm,\u003cbr\u003e(approx. value)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003cbr\u003e\u003c\/strong\u003eapprox. 0.65 mH\/km\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 1.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification in alignment with DIN 47100, colour coded without colour repetition from the 45th core\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 26 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e\u003cspan\u003e 18 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 6.6\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e24.2\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e65.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62721812693361,"sku":"NNC18012","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_d10e6efb-1056-4955-93b1-0bbc91855463.png?v=1764137629"},{"product_id":"26-awg-20c-helukabel-18013-tronic-liyy-pvc-data-cable","title":"26 AWG 20C Helukabel 18013 TRONIC (LiYY) PVC data cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M18001_EN_GB_1.pdf?v=1764135724\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 20C Helukabel 18013 TRONIC (LiYY) PVC data cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. For use where design or constructional measures in the outer diameter require the smallest possible control and signal cables; machine, tool and plant construction, as well as in electronic engineering. Also used in computer systems, scales and in measurement and control technology.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 20C Helukabel Tronic LiYY cable, LiYY PVC data cable, Helukabel LiYY specs, Tronic LiYY cable price, Helukabel signal cable LiYY, 26 AWG 20C LiYY flexible control cable, Helukabel PVC data cable, LiYY multi-core cable, Helukabel LiYY datasheet, 26 AWG 20C LiYY low voltage cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003c\/strong\u003e\u003cbr\u003e0.14 mm²: 350 V\u003cbr\u003e0.25 - 1.5 mm²: 500 V\u003cbr\u003e(not for high power current installation purposes)\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 1200 V\u003cbr\u003e0.34 - 1.5 mm²: 2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 2400 V\u003cbr\u003e0.34 - 1.5 mm²: 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cbr\u003eat 800 Hz \u003cbr\u003e0.14 - 0.25 mm²: approx. 100 pF\/m\u003cbr\u003e0.34 - 1.5 mm²: approx. 150 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance \u003c\/strong\u003e\u003cbr\u003e78 Ohm,\u003cbr\u003e(approx. value)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003cbr\u003e\u003c\/strong\u003eapprox. 0.65 mH\/km\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 1.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification in alignment with DIN 47100, colour coded without colour repetition from the 45th core\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 26 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e\u003cspan\u003e 20 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 6.9\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e26.9\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e70.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62721815740785,"sku":"NNC18013","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_d10e6efb-1056-4955-93b1-0bbc91855463.png?v=1764137629"},{"product_id":"26-awg-21c-helukabel-18014-tronic-liyy-pvc-data-cable","title":"26 AWG 21C Helukabel 18014 TRONIC (LiYY) PVC data cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M18001_EN_GB_1.pdf?v=1764135724\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 21C Helukabel 18014 TRONIC (LiYY) PVC data cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. For use where design or constructional measures in the outer diameter require the smallest possible control and signal cables; machine, tool and plant construction, as well as in electronic engineering. Also used in computer systems, scales and in measurement and control technology.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 21C Helukabel Tronic LiYY cable, LiYY PVC data cable, Helukabel LiYY specs, Tronic LiYY cable price, Helukabel signal cable LiYY, 26 AWG 21C LiYY flexible control cable, Helukabel PVC data cable, LiYY multi-core cable, Helukabel LiYY datasheet, 26 AWG 21C LiYY low voltage cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003c\/strong\u003e\u003cbr\u003e0.14 mm²: 350 V\u003cbr\u003e0.25 - 1.5 mm²: 500 V\u003cbr\u003e(not for high power current installation purposes)\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 1200 V\u003cbr\u003e0.34 - 1.5 mm²: 2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 2400 V\u003cbr\u003e0.34 - 1.5 mm²: 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cbr\u003eat 800 Hz \u003cbr\u003e0.14 - 0.25 mm²: approx. 100 pF\/m\u003cbr\u003e0.34 - 1.5 mm²: approx. 150 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance \u003c\/strong\u003e\u003cbr\u003e78 Ohm,\u003cbr\u003e(approx. value)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003cbr\u003e\u003c\/strong\u003eapprox. 0.65 mH\/km\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 1.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification in alignment with DIN 47100, colour coded without colour repetition from the 45th core\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 26 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e\u003cspan\u003e 21 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 6.9\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e28.2\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e77.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62721824653681,"sku":"NNC18014","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_d10e6efb-1056-4955-93b1-0bbc91855463.png?v=1764137629"},{"product_id":"26-awg-24c-helukabel-18015-tronic-liyy-pvc-data-cable","title":"26 AWG 24C Helukabel 18015 TRONIC (LiYY) PVC data cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M18001_EN_GB_1.pdf?v=1764135724\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 24C Helukabel 18015 TRONIC (LiYY) PVC data cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. For use where design or constructional measures in the outer diameter require the smallest possible control and signal cables; machine, tool and plant construction, as well as in electronic engineering. Also used in computer systems, scales and in measurement and control technology.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 24C Helukabel Tronic LiYY cable, LiYY PVC data cable, Helukabel LiYY specs, Tronic LiYY cable price, Helukabel signal cable LiYY, 26 AWG 24C LiYY flexible control cable, Helukabel PVC data cable, LiYY multi-core cable, Helukabel LiYY datasheet, 26 AWG 24C LiYY low voltage cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003c\/strong\u003e\u003cbr\u003e0.14 mm²: 350 V\u003cbr\u003e0.25 - 1.5 mm²: 500 V\u003cbr\u003e(not for high power current installation purposes)\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 1200 V\u003cbr\u003e0.34 - 1.5 mm²: 2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 2400 V\u003cbr\u003e0.34 - 1.5 mm²: 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cbr\u003eat 800 Hz \u003cbr\u003e0.14 - 0.25 mm²: approx. 100 pF\/m\u003cbr\u003e0.34 - 1.5 mm²: approx. 150 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance \u003c\/strong\u003e\u003cbr\u003e78 Ohm,\u003cbr\u003e(approx. value)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003cbr\u003e\u003c\/strong\u003eapprox. 0.65 mH\/km\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 1.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification in alignment with DIN 47100, colour coded without colour repetition from the 45th core\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 26 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e\u003cspan\u003e 24 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 7.8\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e32.3\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e87.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62721888551281,"sku":"NNC18015","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_d10e6efb-1056-4955-93b1-0bbc91855463.png?v=1764137629"},{"product_id":"26-awg-25c-helukabel-18117-tronic-liyy-pvc-data-cable","title":"26 AWG 25C Helukabel 18117 TRONIC (LiYY) PVC data cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M18001_EN_GB_1.pdf?v=1764135724\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 25C Helukabel 18117 TRONIC (LiYY) PVC data cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. For use where design or constructional measures in the outer diameter require the smallest possible control and signal cables; machine, tool and plant construction, as well as in electronic engineering. Also used in computer systems, scales and in measurement and control technology.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 25C Helukabel Tronic LiYY cable, LiYY PVC data cable, Helukabel LiYY specs, Tronic LiYY cable price, Helukabel signal cable LiYY, 26 AWG 25C LiYY flexible control cable, Helukabel PVC data cable, LiYY multi-core cable, Helukabel LiYY datasheet, 26 AWG 25C LiYY low voltage cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003c\/strong\u003e\u003cbr\u003e0.14 mm²: 350 V\u003cbr\u003e0.25 - 1.5 mm²: 500 V\u003cbr\u003e(not for high power current installation purposes)\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 1200 V\u003cbr\u003e0.34 - 1.5 mm²: 2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 2400 V\u003cbr\u003e0.34 - 1.5 mm²: 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cbr\u003eat 800 Hz \u003cbr\u003e0.14 - 0.25 mm²: approx. 100 pF\/m\u003cbr\u003e0.34 - 1.5 mm²: approx. 150 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance \u003c\/strong\u003e\u003cbr\u003e78 Ohm,\u003cbr\u003e(approx. value)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003cbr\u003e\u003c\/strong\u003eapprox. 0.65 mH\/km\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 1.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification in alignment with DIN 47100, colour coded without colour repetition from the 45th core\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 26 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e\u003cspan\u003e 25 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 7.8\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e33.6 \u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e91.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62722058256753,"sku":"NNC18117","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_d10e6efb-1056-4955-93b1-0bbc91855463.png?v=1764137629"},{"product_id":"26-awg-27c-helukabel-18016-tronic-liyy-pvc-data-cable","title":"26 AWG 27C Helukabel 18016 TRONIC (LiYY) PVC data cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M18001_EN_GB_1.pdf?v=1764135724\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 27C Helukabel 18016 TRONIC (LiYY) PVC data cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. For use where design or constructional measures in the outer diameter require the smallest possible control and signal cables; machine, tool and plant construction, as well as in electronic engineering. Also used in computer systems, scales and in measurement and control technology.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 27C Helukabel Tronic LiYY cable, LiYY PVC data cable, Helukabel LiYY specs, Tronic LiYY cable price, Helukabel signal cable LiYY, 26 AWG 27C LiYY flexible control cable, Helukabel PVC data cable, LiYY multi-core cable, Helukabel LiYY datasheet, 26 AWG 27C LiYY low voltage cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003c\/strong\u003e\u003cbr\u003e0.14 mm²: 350 V\u003cbr\u003e0.25 - 1.5 mm²: 500 V\u003cbr\u003e(not for high power current installation purposes)\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 1200 V\u003cbr\u003e0.34 - 1.5 mm²: 2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 2400 V\u003cbr\u003e0.34 - 1.5 mm²: 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cbr\u003eat 800 Hz \u003cbr\u003e0.14 - 0.25 mm²: approx. 100 pF\/m\u003cbr\u003e0.34 - 1.5 mm²: approx. 150 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance \u003c\/strong\u003e\u003cbr\u003e78 Ohm,\u003cbr\u003e(approx. value)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003cbr\u003e\u003c\/strong\u003eapprox. 0.65 mH\/km\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 1.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification in alignment with DIN 47100, colour coded without colour repetition from the 45th core\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 26 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e\u003cspan\u003e 27 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 7.8\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e36.3\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e97.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62722116747633,"sku":"NNC18016","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_d10e6efb-1056-4955-93b1-0bbc91855463.png?v=1764137629"},{"product_id":"26-awg-30c-helukabel-18017-tronic-liyy-pvc-data-cable","title":"26 AWG 30C Helukabel 18017 TRONIC (LiYY) PVC data cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M18001_EN_GB_1.pdf?v=1764135724\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 30C Helukabel 18017 TRONIC (LiYY) PVC data cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. For use where design or constructional measures in the outer diameter require the smallest possible control and signal cables; machine, tool and plant construction, as well as in electronic engineering. Also used in computer systems, scales and in measurement and control technology.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 30C Helukabel Tronic LiYY cable, LiYY PVC data cable, Helukabel LiYY specs, Tronic LiYY cable price, Helukabel signal cable LiYY, 26 AWG 30C LiYY flexible control cable, Helukabel PVC data cable, LiYY multi-core cable, Helukabel LiYY datasheet, 26 AWG 30C LiYY low voltage cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003c\/strong\u003e\u003cbr\u003e0.14 mm²: 350 V\u003cbr\u003e0.25 - 1.5 mm²: 500 V\u003cbr\u003e(not for high power current installation purposes)\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 1200 V\u003cbr\u003e0.34 - 1.5 mm²: 2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 2400 V\u003cbr\u003e0.34 - 1.5 mm²: 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cbr\u003eat 800 Hz \u003cbr\u003e0.14 - 0.25 mm²: approx. 100 pF\/m\u003cbr\u003e0.34 - 1.5 mm²: approx. 150 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance \u003c\/strong\u003e\u003cbr\u003e78 Ohm,\u003cbr\u003e(approx. value)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003cbr\u003e\u003c\/strong\u003eapprox. 0.65 mH\/km\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 1.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification in alignment with DIN 47100, colour coded without colour repetition from the 45th core\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 26 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e\u003cspan\u003e 30 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 8.2\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e40.3\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e108.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62722117992817,"sku":"NNC18017","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_d10e6efb-1056-4955-93b1-0bbc91855463.png?v=1764137629"},{"product_id":"26-awg-32c-helukabel-18018-tronic-liyy-pvc-data-cable","title":"26 AWG 32C Helukabel 18018 TRONIC (LiYY) PVC data cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M18001_EN_GB_1.pdf?v=1764135724\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 32C Helukabel 18018 TRONIC (LiYY) PVC data cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. For use where design or constructional measures in the outer diameter require the smallest possible control and signal cables; machine, tool and plant construction, as well as in electronic engineering. Also used in computer systems, scales and in measurement and control technology.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 32C Helukabel Tronic LiYY cable, LiYY PVC data cable, Helukabel LiYY specs, Tronic LiYY cable price, Helukabel signal cable LiYY, 26 AWG 32C LiYY flexible control cable, Helukabel PVC data cable, LiYY multi-core cable, Helukabel LiYY datasheet, 26 AWG 32C LiYY low voltage cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003c\/strong\u003e\u003cbr\u003e0.14 mm²: 350 V\u003cbr\u003e0.25 - 1.5 mm²: 500 V\u003cbr\u003e(not for high power current installation purposes)\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 1200 V\u003cbr\u003e0.34 - 1.5 mm²: 2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 2400 V\u003cbr\u003e0.34 - 1.5 mm²: 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cbr\u003eat 800 Hz \u003cbr\u003e0.14 - 0.25 mm²: approx. 100 pF\/m\u003cbr\u003e0.34 - 1.5 mm²: approx. 150 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance \u003c\/strong\u003e\u003cbr\u003e78 Ohm,\u003cbr\u003e(approx. value)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003cbr\u003e\u003c\/strong\u003eapprox. 0.65 mH\/km\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 1.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification in alignment with DIN 47100, colour coded without colour repetition from the 45th core\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 26 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e\u003cspan\u003e 32 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 8.5\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e43.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e114.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62722156790129,"sku":"NNC18018","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_d10e6efb-1056-4955-93b1-0bbc91855463.png?v=1764137629"},{"product_id":"26-awg-36c-helukabel-18019-tronic-liyy-pvc-data-cable","title":"26 AWG 36C Helukabel 18019 TRONIC (LiYY) PVC data cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M18001_EN_GB_1.pdf?v=1764135724\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 36C Helukabel 18019 TRONIC (LiYY) PVC data cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. For use where design or constructional measures in the outer diameter require the smallest possible control and signal cables; machine, tool and plant construction, as well as in electronic engineering. Also used in computer systems, scales and in measurement and control technology.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 36C Helukabel Tronic LiYY cable, LiYY PVC data cable, Helukabel LiYY specs, Tronic LiYY cable price, Helukabel signal cable LiYY, 26 AWG 36C LiYY flexible control cable, Helukabel PVC data cable, LiYY multi-core cable, Helukabel LiYY datasheet, 26 AWG 36C LiYY low voltage cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003c\/strong\u003e\u003cbr\u003e0.14 mm²: 350 V\u003cbr\u003e0.25 - 1.5 mm²: 500 V\u003cbr\u003e(not for high power current installation purposes)\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 1200 V\u003cbr\u003e0.34 - 1.5 mm²: 2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 2400 V\u003cbr\u003e0.34 - 1.5 mm²: 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cbr\u003eat 800 Hz \u003cbr\u003e0.14 - 0.25 mm²: approx. 100 pF\/m\u003cbr\u003e0.34 - 1.5 mm²: approx. 150 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance \u003c\/strong\u003e\u003cbr\u003e78 Ohm,\u003cbr\u003e(approx. value)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003cbr\u003e\u003c\/strong\u003eapprox. 0.65 mH\/km\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 1.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification in alignment with DIN 47100, colour coded without colour repetition from the 45th core\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 26 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e\u003cspan\u003e 36 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 8.8\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e48.4\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e126.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62722178023793,"sku":"NNC18019","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_d10e6efb-1056-4955-93b1-0bbc91855463.png?v=1764137629"},{"product_id":"26-awg-40c-helukabel-18020-tronic-liyy-pvc-data-cable","title":"26 AWG 40C Helukabel 18020 TRONIC (LiYY) PVC data cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M18001_EN_GB_1.pdf?v=1764135724\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 40C Helukabel 18020 TRONIC (LiYY) PVC data cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. For use where design or constructional measures in the outer diameter require the smallest possible control and signal cables; machine, tool and plant construction, as well as in electronic engineering. Also used in computer systems, scales and in measurement and control technology.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 40C Helukabel Tronic LiYY cable, LiYY PVC data cable, Helukabel LiYY specs, Tronic LiYY cable price, Helukabel signal cable LiYY, 26 AWG 40C LiYY flexible control cable, Helukabel PVC data cable, LiYY multi-core cable, Helukabel LiYY datasheet, 26 AWG 40C LiYY low voltage cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003c\/strong\u003e\u003cbr\u003e0.14 mm²: 350 V\u003cbr\u003e0.25 - 1.5 mm²: 500 V\u003cbr\u003e(not for high power current installation purposes)\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 1200 V\u003cbr\u003e0.34 - 1.5 mm²: 2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 2400 V\u003cbr\u003e0.34 - 1.5 mm²: 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cbr\u003eat 800 Hz \u003cbr\u003e0.14 - 0.25 mm²: approx. 100 pF\/m\u003cbr\u003e0.34 - 1.5 mm²: approx. 150 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance \u003c\/strong\u003e\u003cbr\u003e78 Ohm,\u003cbr\u003e(approx. value)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003cbr\u003e\u003c\/strong\u003eapprox. 0.65 mH\/km\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 1.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification in alignment with DIN 47100, colour coded without colour repetition from the 45th core\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 26 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e\u003cspan\u003e 40 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 9.7\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e54.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e139.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62722178515313,"sku":"NNC18020","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_d10e6efb-1056-4955-93b1-0bbc91855463.png?v=1764137629"},{"product_id":"26-awg-42c-helukabel-18021-tronic-liyy-pvc-data-cable","title":"26 AWG 42C Helukabel 18021 TRONIC (LiYY) PVC data cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M18001_EN_GB_1.pdf?v=1764135724\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 42C Helukabel 18021 TRONIC (LiYY) PVC data cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. For use where design or constructional measures in the outer diameter require the smallest possible control and signal cables; machine, tool and plant construction, as well as in electronic engineering. Also used in computer systems, scales and in measurement and control technology.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 42C Helukabel Tronic LiYY cable, LiYY PVC data cable, Helukabel LiYY specs, Tronic LiYY cable price, Helukabel signal cable LiYY, 26 AWG 42C LiYY flexible control cable, Helukabel PVC data cable, LiYY multi-core cable, Helukabel LiYY datasheet, 26 AWG 42C LiYY low voltage cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003c\/strong\u003e\u003cbr\u003e0.14 mm²: 350 V\u003cbr\u003e0.25 - 1.5 mm²: 500 V\u003cbr\u003e(not for high power current installation purposes)\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 1200 V\u003cbr\u003e0.34 - 1.5 mm²: 2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 2400 V\u003cbr\u003e0.34 - 1.5 mm²: 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cbr\u003eat 800 Hz \u003cbr\u003e0.14 - 0.25 mm²: approx. 100 pF\/m\u003cbr\u003e0.34 - 1.5 mm²: approx. 150 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance \u003c\/strong\u003e\u003cbr\u003e78 Ohm,\u003cbr\u003e(approx. value)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003cbr\u003e\u003c\/strong\u003eapprox. 0.65 mH\/km\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 1.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification in alignment with DIN 47100, colour coded without colour repetition from the 45th core\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 26 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e\u003cspan\u003e 42 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 9.7\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e56.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e146.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62722254176625,"sku":"NNC18021","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_d10e6efb-1056-4955-93b1-0bbc91855463.png?v=1764137629"},{"product_id":"26-awg-44c-helukabel-18022-tronic-liyy-pvc-data-cable","title":"26 AWG 44C Helukabel 18022 TRONIC (LiYY) PVC data cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M18001_EN_GB_1.pdf?v=1764135724\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 44C Helukabel 18022 TRONIC (LiYY) PVC data cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. For use where design or constructional measures in the outer diameter require the smallest possible control and signal cables; machine, tool and plant construction, as well as in electronic engineering. Also used in computer systems, scales and in measurement and control technology.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 44C Helukabel Tronic LiYY cable, LiYY PVC data cable, Helukabel LiYY specs, Tronic LiYY cable price, Helukabel signal cable LiYY, 26 AWG 44C LiYY flexible control cable, Helukabel PVC data cable, LiYY multi-core cable, Helukabel LiYY datasheet, 26 AWG 44C LiYY low voltage cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003c\/strong\u003e\u003cbr\u003e0.14 mm²: 350 V\u003cbr\u003e0.25 - 1.5 mm²: 500 V\u003cbr\u003e(not for high power current installation purposes)\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 1200 V\u003cbr\u003e0.34 - 1.5 mm²: 2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 2400 V\u003cbr\u003e0.34 - 1.5 mm²: 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cbr\u003eat 800 Hz \u003cbr\u003e0.14 - 0.25 mm²: approx. 100 pF\/m\u003cbr\u003e0.34 - 1.5 mm²: approx. 150 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance \u003c\/strong\u003e\u003cbr\u003e78 Ohm,\u003cbr\u003e(approx. value)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003cbr\u003e\u003c\/strong\u003eapprox. 0.65 mH\/km\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 1.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification in alignment with DIN 47100, colour coded without colour repetition from the 45th core\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 26 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e\u003cspan\u003e 44 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 10.0\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e59.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e153.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62722359034225,"sku":"NNC18022","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_d10e6efb-1056-4955-93b1-0bbc91855463.png?v=1764137629"},{"product_id":"26-awg-48c-helukabel-18023-tronic-liyy-pvc-data-cable","title":"26  AWG 48C Helukabel 18023 TRONIC (LiYY) PVC data cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M18001_EN_GB_1.pdf?v=1764135724\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 48C Helukabel 18023 TRONIC (LiYY) PVC data cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. For use where design or constructional measures in the outer diameter require the smallest possible control and signal cables; machine, tool and plant construction, as well as in electronic engineering. Also used in computer systems, scales and in measurement and control technology.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 48C Helukabel Tronic LiYY cable, LiYY PVC data cable, Helukabel LiYY specs, Tronic LiYY cable price, Helukabel signal cable LiYY, 26 AWG 48C LiYY flexible control cable, Helukabel PVC data cable, LiYY multi-core cable, Helukabel LiYY datasheet, 26 AWG 48C LiYY low voltage cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003c\/strong\u003e\u003cbr\u003e0.14 mm²: 350 V\u003cbr\u003e0.25 - 1.5 mm²: 500 V\u003cbr\u003e(not for high power current installation purposes)\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 1200 V\u003cbr\u003e0.34 - 1.5 mm²: 2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 2400 V\u003cbr\u003e0.34 - 1.5 mm²: 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cbr\u003eat 800 Hz \u003cbr\u003e0.14 - 0.25 mm²: approx. 100 pF\/m\u003cbr\u003e0.34 - 1.5 mm²: approx. 150 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance \u003c\/strong\u003e\u003cbr\u003e78 Ohm,\u003cbr\u003e(approx. value)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003cbr\u003e\u003c\/strong\u003eapprox. 0.65 mH\/km\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 1.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification in alignment with DIN 47100, colour coded without colour repetition from the 45th core\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 26 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e\u003cspan\u003e 48 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 10.2\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e65.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e164.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62722473984369,"sku":"NNC18023","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_d10e6efb-1056-4955-93b1-0bbc91855463.png?v=1764137629"},{"product_id":"26-awg-52c-helukabel-18024-tronic-liyy-pvc-data-cable","title":"26 AWG 52C Helukabel 18024 TRONIC (LiYY) PVC data cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M18001_EN_GB_1.pdf?v=1764135724\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 52C Helukabel 18024 TRONIC (LiYY) PVC data cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. For use where design or constructional measures in the outer diameter require the smallest possible control and signal cables; machine, tool and plant construction, as well as in electronic engineering. Also used in computer systems, scales and in measurement and control technology.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 52C Helukabel Tronic LiYY cable, LiYY PVC data cable, Helukabel LiYY specs, Tronic LiYY cable price, Helukabel signal cable LiYY, 26 AWG 52C LiYY flexible control cable, Helukabel PVC data cable, LiYY multi-core cable, Helukabel LiYY datasheet, 26 AWG 52C LiYY low voltage cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003c\/strong\u003e\u003cbr\u003e0.14 mm²: 350 V\u003cbr\u003e0.25 - 1.5 mm²: 500 V\u003cbr\u003e(not for high power current installation purposes)\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 1200 V\u003cbr\u003e0.34 - 1.5 mm²: 2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 2400 V\u003cbr\u003e0.34 - 1.5 mm²: 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cbr\u003eat 800 Hz \u003cbr\u003e0.14 - 0.25 mm²: approx. 100 pF\/m\u003cbr\u003e0.34 - 1.5 mm²: approx. 150 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance \u003c\/strong\u003e\u003cbr\u003e78 Ohm,\u003cbr\u003e(approx. value)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003cbr\u003e\u003c\/strong\u003eapprox. 0.65 mH\/km\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 1.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification in alignment with DIN 47100, colour coded without colour repetition from the 45th core\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 26 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e\u003cspan\u003e 52 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 10.4\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e70.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e173.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62722514780529,"sku":"NNC18024","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_d10e6efb-1056-4955-93b1-0bbc91855463.png?v=1764137629"},{"product_id":"26-awg-56c-helukabel-18025-tronic-liyy-pvc-data-cable","title":"26 AWG 56C Helukabel 18025 TRONIC (LiYY) PVC data cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M18001_EN_GB_1.pdf?v=1764135724\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 56C Helukabel 18025 TRONIC (LiYY) PVC data cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. For use where design or constructional measures in the outer diameter require the smallest possible control and signal cables; machine, tool and plant construction, as well as in electronic engineering. Also used in computer systems, scales and in measurement and control technology.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 56C Helukabel Tronic LiYY cable, LiYY PVC data cable, Helukabel LiYY specs, Tronic LiYY cable price, Helukabel signal cable LiYY, 26 AWG 56C LiYY flexible control cable, Helukabel PVC data cable, LiYY multi-core cable, Helukabel LiYY datasheet, 26 AWG 56C LiYY low voltage cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003c\/strong\u003e\u003cbr\u003e0.14 mm²: 350 V\u003cbr\u003e0.25 - 1.5 mm²: 500 V\u003cbr\u003e(not for high power current installation purposes)\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 1200 V\u003cbr\u003e0.34 - 1.5 mm²: 2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 2400 V\u003cbr\u003e0.34 - 1.5 mm²: 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cbr\u003eat 800 Hz \u003cbr\u003e0.14 - 0.25 mm²: approx. 100 pF\/m\u003cbr\u003e0.34 - 1.5 mm²: approx. 150 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance \u003c\/strong\u003e\u003cbr\u003e78 Ohm,\u003cbr\u003e(approx. value)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003cbr\u003e\u003c\/strong\u003eapprox. 0.65 mH\/km\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 1.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification in alignment with DIN 47100, colour coded without colour repetition from the 45th core\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 26 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e\u003cspan\u003e 56 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 10.9\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e75.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e187.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62722702115185,"sku":"NNC18025","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_d10e6efb-1056-4955-93b1-0bbc91855463.png?v=1764137629"},{"product_id":"26-awg-61c-helukabel-18026-tronic-liyy-pvc-data-cable","title":"26 AWG 61C Helukabel 18026 TRONIC (LiYY) PVC data cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M18001_EN_GB_1.pdf?v=1764135724\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 61C Helukabel 18026 TRONIC (LiYY) PVC data cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. For use where design or constructional measures in the outer diameter require the smallest possible control and signal cables; machine, tool and plant construction, as well as in electronic engineering. Also used in computer systems, scales and in measurement and control technology.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 61C Helukabel Tronic LiYY cable, LiYY PVC data cable, Helukabel LiYY specs, Tronic LiYY cable price, Helukabel signal cable LiYY, 26 AWG 61C LiYY flexible control cable, Helukabel PVC data cable, LiYY multi-core cable, Helukabel LiYY datasheet, 26 AWG 61C LiYY low voltage cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003c\/strong\u003e\u003cbr\u003e0.14 mm²: 350 V\u003cbr\u003e0.25 - 1.5 mm²: 500 V\u003cbr\u003e(not for high power current installation purposes)\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 1200 V\u003cbr\u003e0.34 - 1.5 mm²: 2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 2400 V\u003cbr\u003e0.34 - 1.5 mm²: 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cbr\u003eat 800 Hz \u003cbr\u003e0.14 - 0.25 mm²: approx. 100 pF\/m\u003cbr\u003e0.34 - 1.5 mm²: approx. 150 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance \u003c\/strong\u003e\u003cbr\u003e78 Ohm,\u003cbr\u003e(approx. value)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003cbr\u003e\u003c\/strong\u003eapprox. 0.65 mH\/km\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 1.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification in alignment with DIN 47100, colour coded without colour repetition from the 45th core\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 26 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e\u003cspan\u003e 61 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 11.2\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e82.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e204.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62722743894385,"sku":"NNC18026","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_d10e6efb-1056-4955-93b1-0bbc91855463.png?v=1764137629"},{"product_id":"24-awg-2c-helukabel-18029-tronic-liyy-pvc-data-cable","title":"24 AWG 2C Helukabel 18029 TRONIC (LiYY) PVC data cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M18001_EN_GB_1.pdf?v=1764135724\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e24 AWG 2C Helukabel 18029 TRONIC (LiYY) PVC data cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. For use where design or constructional measures in the outer diameter require the smallest possible control and signal cables; machine, tool and plant construction, as well as in electronic engineering. Also used in computer systems, scales and in measurement and control technology.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e24 AWG 2C Helukabel Tronic LiYY cable, LiYY PVC data cable, Helukabel LiYY specs, Tronic LiYY cable price, Helukabel signal cable LiYY, 24 AWG 2C LiYY flexible control cable, Helukabel PVC data cable, LiYY multi-core cable, Helukabel LiYY datasheet, 24 AWG 2C  LiYY low voltage cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003c\/strong\u003e\u003cbr\u003e0.14 mm²: 350 V\u003cbr\u003e0.25 - 1.5 mm²: 500 V\u003cbr\u003e(not for high power current installation purposes)\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 1200 V\u003cbr\u003e0.34 - 1.5 mm²: 2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 2400 V\u003cbr\u003e0.34 - 1.5 mm²: 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cbr\u003eat 800 Hz \u003cbr\u003e0.14 - 0.25 mm²: approx. 100 pF\/m\u003cbr\u003e0.34 - 1.5 mm²: approx. 150 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance \u003c\/strong\u003e\u003cbr\u003e78 Ohm,\u003cbr\u003e(approx. value)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003cbr\u003e\u003c\/strong\u003eapprox. 0.65 mH\/km\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 1.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification in alignment with DIN 47100, colour coded without colour repetition from the 45th core\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 24 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e\u003cspan\u003e 2 x 0.25\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 3.8\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e4.8\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e18.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62722818048369,"sku":"NNC18029","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_d10e6efb-1056-4955-93b1-0bbc91855463.png?v=1764137629"},{"product_id":"24-awg-3c-helukabel-18030-tronic-liyy-pvc-data-cable","title":"24 AWG 3C Helukabel 18030 TRONIC (LiYY) PVC data cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M18001_EN_GB_1.pdf?v=1764135724\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e24 AWG 3C Helukabel 18030 TRONIC (LiYY) PVC data cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. For use where design or constructional measures in the outer diameter require the smallest possible control and signal cables; machine, tool and plant construction, as well as in electronic engineering. Also used in computer systems, scales and in measurement and control technology.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e24 AWG 3C Helukabel Tronic LiYY cable, LiYY PVC data cable, Helukabel LiYY specs, Tronic LiYY cable price, Helukabel signal cable LiYY, 24 AWG 3C LiYY flexible control cable, Helukabel PVC data cable, LiYY multi-core cable, Helukabel LiYY datasheet, 24 AWG 3C  LiYY low voltage cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003c\/strong\u003e\u003cbr\u003e0.14 mm²: 350 V\u003cbr\u003e0.25 - 1.5 mm²: 500 V\u003cbr\u003e(not for high power current installation purposes)\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 1200 V\u003cbr\u003e0.34 - 1.5 mm²: 2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 2400 V\u003cbr\u003e0.34 - 1.5 mm²: 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cbr\u003eat 800 Hz \u003cbr\u003e0.14 - 0.25 mm²: approx. 100 pF\/m\u003cbr\u003e0.34 - 1.5 mm²: approx. 150 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance \u003c\/strong\u003e\u003cbr\u003e78 Ohm,\u003cbr\u003e(approx. value)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003cbr\u003e\u003c\/strong\u003eapprox. 0.65 mH\/km\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 1.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification in alignment with DIN 47100, colour coded without colour repetition from the 45th core\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 24 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e\u003cspan\u003e 3 x 0.25\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 4.0\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e7.2\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e22.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62722847146353,"sku":"NNC18030","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_d10e6efb-1056-4955-93b1-0bbc91855463.png?v=1764137629"},{"product_id":"24-awg-4c-helukabel-18031-tronic-liyy-pvc-data-cable","title":"24 AWG 4C Helukabel 18031 TRONIC (LiYY) PVC data cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M18001_EN_GB_1.pdf?v=1764135724\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e24 AWG 4C Helukabel 18031 TRONIC (LiYY) PVC data cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. For use where design or constructional measures in the outer diameter require the smallest possible control and signal cables; machine, tool and plant construction, as well as in electronic engineering. Also used in computer systems, scales and in measurement and control technology.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e24 AWG 4C Helukabel Tronic LiYY cable, LiYY PVC data cable, Helukabel LiYY specs, Tronic LiYY cable price, Helukabel signal cable LiYY, 24 AWG 4C LiYY flexible control cable, Helukabel PVC data cable, LiYY multi-core cable, Helukabel LiYY datasheet, 24 AWG 4C  LiYY low voltage cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003c\/strong\u003e\u003cbr\u003e0.14 mm²: 350 V\u003cbr\u003e0.25 - 1.5 mm²: 500 V\u003cbr\u003e(not for high power current installation purposes)\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 1200 V\u003cbr\u003e0.34 - 1.5 mm²: 2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 2400 V\u003cbr\u003e0.34 - 1.5 mm²: 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cbr\u003eat 800 Hz \u003cbr\u003e0.14 - 0.25 mm²: approx. 100 pF\/m\u003cbr\u003e0.34 - 1.5 mm²: approx. 150 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance \u003c\/strong\u003e\u003cbr\u003e78 Ohm,\u003cbr\u003e(approx. value)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003cbr\u003e\u003c\/strong\u003eapprox. 0.65 mH\/km\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 1.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification in alignment with DIN 47100, colour coded without colour repetition from the 45th core\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 24 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e\u003cspan\u003e 4 x 0.25\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 4.5\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e9.6\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e26.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62728446312817,"sku":"NNC18031","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_d10e6efb-1056-4955-93b1-0bbc91855463.png?v=1764137629"},{"product_id":"24-awg-5c-helukabel-18032-tronic-liyy-pvc-data-cable","title":"24 AWG 5C Helukabel 18032 TRONIC (LiYY) PVC data cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M18001_EN_GB_1.pdf?v=1764135724\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e24 AWG 5C Helukabel 18032 TRONIC (LiYY) PVC data cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. For use where design or constructional measures in the outer diameter require the smallest possible control and signal cables; machine, tool and plant construction, as well as in electronic engineering. Also used in computer systems, scales and in measurement and control technology.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e24 AWG 5C Helukabel Tronic LiYY cable, LiYY PVC data cable, Helukabel LiYY specs, Tronic LiYY cable price, Helukabel signal cable LiYY, 24 AWG 5C LiYY flexible control cable, Helukabel PVC data cable, LiYY multi-core cable, Helukabel LiYY datasheet, 24 AWG 5C  LiYY low voltage cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003c\/strong\u003e\u003cbr\u003e0.14 mm²: 350 V\u003cbr\u003e0.25 - 1.5 mm²: 500 V\u003cbr\u003e(not for high power current installation purposes)\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 1200 V\u003cbr\u003e0.34 - 1.5 mm²: 2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 2400 V\u003cbr\u003e0.34 - 1.5 mm²: 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cbr\u003eat 800 Hz \u003cbr\u003e0.14 - 0.25 mm²: approx. 100 pF\/m\u003cbr\u003e0.34 - 1.5 mm²: approx. 150 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance \u003c\/strong\u003e\u003cbr\u003e78 Ohm,\u003cbr\u003e(approx. value)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003cbr\u003e\u003c\/strong\u003eapprox. 0.65 mH\/km\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 1.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification in alignment with DIN 47100, colour coded without colour repetition from the 45th core\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 24 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e\u003cspan\u003e 5 x 0.25\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 4.9\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e12.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e30.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62728448672113,"sku":"NNC18032","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_d10e6efb-1056-4955-93b1-0bbc91855463.png?v=1764137629"},{"product_id":"24-awg-6c-helukabel-18033-tronic-liyy-pvc-data-cable","title":"24 AWG 6C Helukabel 18033 TRONIC (LiYY) PVC data cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M18001_EN_GB_1.pdf?v=1764135724\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e24 AWG 6C Helukabel 18033 TRONIC (LiYY) PVC data cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. For use where design or constructional measures in the outer diameter require the smallest possible control and signal cables; machine, tool and plant construction, as well as in electronic engineering. Also used in computer systems, scales and in measurement and control technology.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e24 AWG 6C Helukabel Tronic LiYY cable, LiYY PVC data cable, Helukabel LiYY specs, Tronic LiYY cable price, Helukabel signal cable LiYY, 24 AWG 6C LiYY flexible control cable, Helukabel PVC data cable, LiYY multi-core cable, Helukabel LiYY datasheet, 24 AWG 6C  LiYY low voltage cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003c\/strong\u003e\u003cbr\u003e0.14 mm²: 350 V\u003cbr\u003e0.25 - 1.5 mm²: 500 V\u003cbr\u003e(not for high power current installation purposes)\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 1200 V\u003cbr\u003e0.34 - 1.5 mm²: 2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 2400 V\u003cbr\u003e0.34 - 1.5 mm²: 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cbr\u003eat 800 Hz \u003cbr\u003e0.14 - 0.25 mm²: approx. 100 pF\/m\u003cbr\u003e0.34 - 1.5 mm²: approx. 150 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance \u003c\/strong\u003e\u003cbr\u003e78 Ohm,\u003cbr\u003e(approx. value)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003cbr\u003e\u003c\/strong\u003eapprox. 0.65 mH\/km\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 1.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification in alignment with DIN 47100, colour coded without colour repetition from the 45th core\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 24 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e\u003cspan\u003e 6 x 0.25\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 5.3\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e14.4 \u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e36.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62728452342129,"sku":"NNC18033","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_d10e6efb-1056-4955-93b1-0bbc91855463.png?v=1764137629"},{"product_id":"24-awg-7c-helukabel-18034-tronic-liyy-pvc-data-cable","title":"24 AWG 7C Helukabel 18034 TRONIC (LiYY) PVC data cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M18001_EN_GB_1.pdf?v=1764135724\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e24 AWG 7C Helukabel 18034 TRONIC (LiYY) PVC data cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. For use where design or constructional measures in the outer diameter require the smallest possible control and signal cables; machine, tool and plant construction, as well as in electronic engineering. Also used in computer systems, scales and in measurement and control technology.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e24 AWG 7C Helukabel Tronic LiYY cable, LiYY PVC data cable, Helukabel LiYY specs, Tronic LiYY cable price, Helukabel signal cable LiYY, 24 AWG 7C LiYY flexible control cable, Helukabel PVC data cable, LiYY multi-core cable, Helukabel LiYY datasheet, 24 AWG 7C  LiYY low voltage cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003c\/strong\u003e\u003cbr\u003e0.14 mm²: 350 V\u003cbr\u003e0.25 - 1.5 mm²: 500 V\u003cbr\u003e(not for high power current installation purposes)\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 1200 V\u003cbr\u003e0.34 - 1.5 mm²: 2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 2400 V\u003cbr\u003e0.34 - 1.5 mm²: 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cbr\u003eat 800 Hz \u003cbr\u003e0.14 - 0.25 mm²: approx. 100 pF\/m\u003cbr\u003e0.34 - 1.5 mm²: approx. 150 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance \u003c\/strong\u003e\u003cbr\u003e78 Ohm,\u003cbr\u003e(approx. value)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003cbr\u003e\u003c\/strong\u003eapprox. 0.65 mH\/km\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 1.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification in alignment with DIN 47100, colour coded without colour repetition from the 45th core\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 24 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e\u003cspan\u003e 7 x 0.25\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 5.3\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e16.8\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e42.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62728456470897,"sku":"NNC18034","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_d10e6efb-1056-4955-93b1-0bbc91855463.png?v=1764137629"},{"product_id":"24-awg-8c-helukabel-18035-tronic-liyy-pvc-data-cable","title":"24 AWG 8C Helukabel 18035 TRONIC (LiYY) PVC data cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M18001_EN_GB_1.pdf?v=1764135724\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e24 AWG 8C Helukabel 18035 TRONIC (LiYY) PVC data cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. For use where design or constructional measures in the outer diameter require the smallest possible control and signal cables; machine, tool and plant construction, as well as in electronic engineering. Also used in computer systems, scales and in measurement and control technology.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e24 AWG 8C Helukabel Tronic LiYY cable, LiYY PVC data cable, Helukabel LiYY specs, Tronic LiYY cable price, Helukabel signal cable LiYY, 24 AWG 8C LiYY flexible control cable, Helukabel PVC data cable, LiYY multi-core cable, Helukabel LiYY datasheet, 24 AWG 8C  LiYY low voltage cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003c\/strong\u003e\u003cbr\u003e0.14 mm²: 350 V\u003cbr\u003e0.25 - 1.5 mm²: 500 V\u003cbr\u003e(not for high power current installation purposes)\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 1200 V\u003cbr\u003e0.34 - 1.5 mm²: 2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 2400 V\u003cbr\u003e0.34 - 1.5 mm²: 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cbr\u003eat 800 Hz \u003cbr\u003e0.14 - 0.25 mm²: approx. 100 pF\/m\u003cbr\u003e0.34 - 1.5 mm²: approx. 150 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance \u003c\/strong\u003e\u003cbr\u003e78 Ohm,\u003cbr\u003e(approx. value)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003cbr\u003e\u003c\/strong\u003eapprox. 0.65 mH\/km\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 1.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification in alignment with DIN 47100, colour coded without colour repetition from the 45th core\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 24 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e\u003cspan\u003e 8 x 0.25\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 6.3\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e19.2\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e49.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62728457027953,"sku":"NNC18035","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_d10e6efb-1056-4955-93b1-0bbc91855463.png?v=1764137629"},{"product_id":"24-awg-10c-helukabel-18036-tronic-liyy-pvc-data-cable","title":"24 AWG 10C Helukabel 18036 TRONIC (LiYY) PVC data cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M18001_EN_GB_1.pdf?v=1764135724\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e24 AWG 10C Helukabel 18036 TRONIC (LiYY) PVC data cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. For use where design or constructional measures in the outer diameter require the smallest possible control and signal cables; machine, tool and plant construction, as well as in electronic engineering. Also used in computer systems, scales and in measurement and control technology.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e24 AWG 10C Helukabel Tronic LiYY cable, LiYY PVC data cable, Helukabel LiYY specs, Tronic LiYY cable price, Helukabel signal cable LiYY, 24 AWG 10C LiYY flexible control cable, Helukabel PVC data cable, LiYY multi-core cable, Helukabel LiYY datasheet, 24 AWG 10C  LiYY low voltage cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003c\/strong\u003e\u003cbr\u003e0.14 mm²: 350 V\u003cbr\u003e0.25 - 1.5 mm²: 500 V\u003cbr\u003e(not for high power current installation purposes)\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 1200 V\u003cbr\u003e0.34 - 1.5 mm²: 2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 2400 V\u003cbr\u003e0.34 - 1.5 mm²: 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cbr\u003eat 800 Hz \u003cbr\u003e0.14 - 0.25 mm²: approx. 100 pF\/m\u003cbr\u003e0.34 - 1.5 mm²: approx. 150 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance \u003c\/strong\u003e\u003cbr\u003e78 Ohm,\u003cbr\u003e(approx. value)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003cbr\u003e\u003c\/strong\u003eapprox. 0.65 mH\/km\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 1.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification in alignment with DIN 47100, colour coded without colour repetition from the 45th core\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 24 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e\u003cspan\u003e 10 x 0.25\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 6.8\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e24.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e57.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62728462041457,"sku":"NNC18036","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_d10e6efb-1056-4955-93b1-0bbc91855463.png?v=1764137629"},{"product_id":"24-awg-12c-helukabel-18037-tronic-liyy-pvc-data-cable","title":"24 AWG 12C Helukabel 18037 TRONIC (LiYY) PVC data cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M18001_EN_GB_1.pdf?v=1764135724\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e24 AWG 12C Helukabel 18037 TRONIC (LiYY) PVC data cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. For use where design or constructional measures in the outer diameter require the smallest possible control and signal cables; machine, tool and plant construction, as well as in electronic engineering. Also used in computer systems, scales and in measurement and control technology.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e24 AWG 12C Helukabel Tronic LiYY cable, LiYY PVC data cable, Helukabel LiYY specs, Tronic LiYY cable price, Helukabel signal cable LiYY, 24 AWG 12C LiYY flexible control cable, Helukabel PVC data cable, LiYY multi-core cable, Helukabel LiYY datasheet, 24 AWG 12C  LiYY low voltage cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003c\/strong\u003e\u003cbr\u003e0.14 mm²: 350 V\u003cbr\u003e0.25 - 1.5 mm²: 500 V\u003cbr\u003e(not for high power current installation purposes)\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 1200 V\u003cbr\u003e0.34 - 1.5 mm²: 2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 2400 V\u003cbr\u003e0.34 - 1.5 mm²: 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cbr\u003eat 800 Hz \u003cbr\u003e0.14 - 0.25 mm²: approx. 100 pF\/m\u003cbr\u003e0.34 - 1.5 mm²: approx. 150 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance \u003c\/strong\u003e\u003cbr\u003e78 Ohm,\u003cbr\u003e(approx. value)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003cbr\u003e\u003c\/strong\u003eapprox. 0.65 mH\/km\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 1.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification in alignment with DIN 47100, colour coded without colour repetition from the 45th core\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 24 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e\u003cspan\u003e 12 x 0.25\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 7.0\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e28.8\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e66.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62728479506801,"sku":"NNC18037","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_d10e6efb-1056-4955-93b1-0bbc91855463.png?v=1764137629"},{"product_id":"24-awg-14c-helukabel-18038-tronic-liyy-pvc-data-cable","title":"24 AWG 14C Helukabel 18038 TRONIC (LiYY) PVC data cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M18001_EN_GB_1.pdf?v=1764135724\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e24 AWG 14C Helukabel 18038 TRONIC (LiYY) PVC data cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. For use where design or constructional measures in the outer diameter require the smallest possible control and signal cables; machine, tool and plant construction, as well as in electronic engineering. Also used in computer systems, scales and in measurement and control technology.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e24 AWG 14C Helukabel Tronic LiYY cable, LiYY PVC data cable, Helukabel LiYY specs, Tronic LiYY cable price, Helukabel signal cable LiYY, 24 AWG 14C LiYY flexible control cable, Helukabel PVC data cable, LiYY multi-core cable, Helukabel LiYY datasheet, 24 AWG 14C  LiYY low voltage cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003c\/strong\u003e\u003cbr\u003e0.14 mm²: 350 V\u003cbr\u003e0.25 - 1.5 mm²: 500 V\u003cbr\u003e(not for high power current installation purposes)\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 1200 V\u003cbr\u003e0.34 - 1.5 mm²: 2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 2400 V\u003cbr\u003e0.34 - 1.5 mm²: 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cbr\u003eat 800 Hz \u003cbr\u003e0.14 - 0.25 mm²: approx. 100 pF\/m\u003cbr\u003e0.34 - 1.5 mm²: approx. 150 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance \u003c\/strong\u003e\u003cbr\u003e78 Ohm,\u003cbr\u003e(approx. value)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003cbr\u003e\u003c\/strong\u003eapprox. 0.65 mH\/km\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 1.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification in alignment with DIN 47100, colour coded without colour repetition from the 45th core\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 24 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e\u003cspan\u003e 14 x 0.25\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 7.3\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e33.6 \u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e75.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62728554054001,"sku":"NNC18038","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_d10e6efb-1056-4955-93b1-0bbc91855463.png?v=1764137629"},{"product_id":"24-awg-16c-helukabel-18039-tronic-liyy-pvc-data-cable","title":"24 AWG 16C Helukabel 18039 TRONIC (LiYY) PVC data cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M18001_EN_GB_1.pdf?v=1764135724\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e24 AWG 16C Helukabel 18039 TRONIC (LiYY) PVC data cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. For use where design or constructional measures in the outer diameter require the smallest possible control and signal cables; machine, tool and plant construction, as well as in electronic engineering. Also used in computer systems, scales and in measurement and control technology.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e24 AWG 16C Helukabel Tronic LiYY cable, LiYY PVC data cable, Helukabel LiYY specs, Tronic LiYY cable price, Helukabel signal cable LiYY, 24 AWG 16C LiYY flexible control cable, Helukabel PVC data cable, LiYY multi-core cable, Helukabel LiYY datasheet, 24 AWG 16C  LiYY low voltage cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003c\/strong\u003e\u003cbr\u003e0.14 mm²: 350 V\u003cbr\u003e0.25 - 1.5 mm²: 500 V\u003cbr\u003e(not for high power current installation purposes)\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 1200 V\u003cbr\u003e0.34 - 1.5 mm²: 2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 2400 V\u003cbr\u003e0.34 - 1.5 mm²: 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cbr\u003eat 800 Hz \u003cbr\u003e0.14 - 0.25 mm²: approx. 100 pF\/m\u003cbr\u003e0.34 - 1.5 mm²: approx. 150 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance \u003c\/strong\u003e\u003cbr\u003e78 Ohm,\u003cbr\u003e(approx. value)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003cbr\u003e\u003c\/strong\u003eapprox. 0.65 mH\/km\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 1.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification in alignment with DIN 47100, colour coded without colour repetition from the 45th core\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 24 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e\u003cspan\u003e 16 x 0.25\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 7.9\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e38.4\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e84.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62728567587185,"sku":"NNC18039","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_d10e6efb-1056-4955-93b1-0bbc91855463.png?v=1764137629"},{"product_id":"24-awg-18c-helukabel-18040-tronic-liyy-pvc-data-cable","title":"24 AWG 18C Helukabel 18040 TRONIC (LiYY) PVC data cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M18001_EN_GB_1.pdf?v=1764135724\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e24 AWG 18C Helukabel 18040 TRONIC (LiYY) PVC data cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. For use where design or constructional measures in the outer diameter require the smallest possible control and signal cables; machine, tool and plant construction, as well as in electronic engineering. Also used in computer systems, scales and in measurement and control technology.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e24 AWG 18C Helukabel Tronic LiYY cable, LiYY PVC data cable, Helukabel LiYY specs, Tronic LiYY cable price, Helukabel signal cable LiYY, 24 AWG 18C LiYY flexible control cable, Helukabel PVC data cable, LiYY multi-core cable, Helukabel LiYY datasheet, 24 AWG 18C  LiYY low voltage cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003c\/strong\u003e\u003cbr\u003e0.14 mm²: 350 V\u003cbr\u003e0.25 - 1.5 mm²: 500 V\u003cbr\u003e(not for high power current installation purposes)\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 1200 V\u003cbr\u003e0.34 - 1.5 mm²: 2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 2400 V\u003cbr\u003e0.34 - 1.5 mm²: 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cbr\u003eat 800 Hz \u003cbr\u003e0.14 - 0.25 mm²: approx. 100 pF\/m\u003cbr\u003e0.34 - 1.5 mm²: approx. 150 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance \u003c\/strong\u003e\u003cbr\u003e78 Ohm,\u003cbr\u003e(approx. value)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003cbr\u003e\u003c\/strong\u003eapprox. 0.65 mH\/km\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 1.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification in alignment with DIN 47100, colour coded without colour repetition from the 45th core\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 24 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e\u003cspan\u003e 18 x 0.25\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 8.3\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e43.2\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e94.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62728621752689,"sku":"NNC18040","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_d10e6efb-1056-4955-93b1-0bbc91855463.png?v=1764137629"},{"product_id":"24-awg-19c-helukabel-18114-tronic-liyy-pvc-data-cable","title":"24 AWG 19C Helukabel 18114 TRONIC (LiYY) PVC data cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M18001_EN_GB_1.pdf?v=1764135724\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e24 AWG 19C Helukabel 18114 TRONIC (LiYY) PVC data cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. For use where design or constructional measures in the outer diameter require the smallest possible control and signal cables; machine, tool and plant construction, as well as in electronic engineering. Also used in computer systems, scales and in measurement and control technology.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e24 AWG 19C Helukabel Tronic LiYY cable, LiYY PVC data cable, Helukabel LiYY specs, Tronic LiYY cable price, Helukabel signal cable LiYY, 24 AWG 19C LiYY flexible control cable, Helukabel PVC data cable, LiYY multi-core cable, Helukabel LiYY datasheet, 24 AWG 19C  LiYY low voltage cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003c\/strong\u003e\u003cbr\u003e0.14 mm²: 350 V\u003cbr\u003e0.25 - 1.5 mm²: 500 V\u003cbr\u003e(not for high power current installation purposes)\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 1200 V\u003cbr\u003e0.34 - 1.5 mm²: 2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 2400 V\u003cbr\u003e0.34 - 1.5 mm²: 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cbr\u003eat 800 Hz \u003cbr\u003e0.14 - 0.25 mm²: approx. 100 pF\/m\u003cbr\u003e0.34 - 1.5 mm²: approx. 150 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance \u003c\/strong\u003e\u003cbr\u003e78 Ohm,\u003cbr\u003e(approx. value)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003cbr\u003e\u003c\/strong\u003eapprox. 0.65 mH\/km\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 1.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification in alignment with DIN 47100, colour coded without colour repetition from the 45th core\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 24 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e\u003cspan\u003e 19 x 0.25\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 8.3\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e46.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e98.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62728629551473,"sku":"NNC18114","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_d10e6efb-1056-4955-93b1-0bbc91855463.png?v=1764137629"},{"product_id":"24-awg-20c-helukabel-18041-tronic-liyy-pvc-data-cable","title":"24 AWG 20C Helukabel 18041 TRONIC (LiYY) PVC data cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M18001_EN_GB_1.pdf?v=1764135724\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e24 AWG 20C Helukabel 18041 TRONIC (LiYY) PVC data cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. For use where design or constructional measures in the outer diameter require the smallest possible control and signal cables; machine, tool and plant construction, as well as in electronic engineering. Also used in computer systems, scales and in measurement and control technology.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e24 AWG 20C Helukabel Tronic LiYY cable, LiYY PVC data cable, Helukabel LiYY specs, Tronic LiYY cable price, Helukabel signal cable LiYY, 24 AWG 20C LiYY flexible control cable, Helukabel PVC data cable, LiYY multi-core cable, Helukabel LiYY datasheet, 24 AWG 20C  LiYY low voltage cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003c\/strong\u003e\u003cbr\u003e0.14 mm²: 350 V\u003cbr\u003e0.25 - 1.5 mm²: 500 V\u003cbr\u003e(not for high power current installation purposes)\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 1200 V\u003cbr\u003e0.34 - 1.5 mm²: 2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 2400 V\u003cbr\u003e0.34 - 1.5 mm²: 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cbr\u003eat 800 Hz \u003cbr\u003e0.14 - 0.25 mm²: approx. 100 pF\/m\u003cbr\u003e0.34 - 1.5 mm²: approx. 150 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance \u003c\/strong\u003e\u003cbr\u003e78 Ohm,\u003cbr\u003e(approx. value)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003cbr\u003e\u003c\/strong\u003eapprox. 0.65 mH\/km\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 1.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification in alignment with DIN 47100, colour coded without colour repetition from the 45th core\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 24 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e\u003cspan\u003e 20 x 0.25\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 8.7\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e48.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e103.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62728633614705,"sku":"NNC18041","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_d10e6efb-1056-4955-93b1-0bbc91855463.png?v=1764137629"},{"product_id":"24-awg-21c-helukabel-18042-tronic-liyy-pvc-data-cable","title":"24 AWG 21C Helukabel 18042 TRONIC (LiYY) PVC data cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M18001_EN_GB_1.pdf?v=1764135724\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e24 AWG 21C Helukabel 18042 TRONIC (LiYY) PVC data cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. For use where design or constructional measures in the outer diameter require the smallest possible control and signal cables; machine, tool and plant construction, as well as in electronic engineering. Also used in computer systems, scales and in measurement and control technology.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e24 AWG 21C Helukabel Tronic LiYY cable, LiYY PVC data cable, Helukabel LiYY specs, Tronic LiYY cable price, Helukabel signal cable LiYY, 24 AWG 21C LiYY flexible control cable, Helukabel PVC data cable, LiYY multi-core cable, Helukabel LiYY datasheet, 24 AWG 21C  LiYY low voltage cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003c\/strong\u003e\u003cbr\u003e0.14 mm²: 350 V\u003cbr\u003e0.25 - 1.5 mm²: 500 V\u003cbr\u003e(not for high power current installation purposes)\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 1200 V\u003cbr\u003e0.34 - 1.5 mm²: 2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 2400 V\u003cbr\u003e0.34 - 1.5 mm²: 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cbr\u003eat 800 Hz \u003cbr\u003e0.14 - 0.25 mm²: approx. 100 pF\/m\u003cbr\u003e0.34 - 1.5 mm²: approx. 150 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance \u003c\/strong\u003e\u003cbr\u003e78 Ohm,\u003cbr\u003e(approx. value)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003cbr\u003e\u003c\/strong\u003eapprox. 0.65 mH\/km\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 1.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification in alignment with DIN 47100, colour coded without colour repetition from the 45th core\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 24 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e\u003cspan\u003e 21 x 0.25\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 8.7\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e50.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e107.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62728639021425,"sku":"NNC18042","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_d10e6efb-1056-4955-93b1-0bbc91855463.png?v=1764137629"},{"product_id":"24-awg-24c-helukabel-18043-tronic-liyy-pvc-data-cable","title":"24 AWG 24C Helukabel 18043 TRONIC (LiYY) PVC data cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M18001_EN_GB_1.pdf?v=1764135724\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e24 AWG 24C Helukabel 18043 TRONIC (LiYY) PVC data cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. For use where design or constructional measures in the outer diameter require the smallest possible control and signal cables; machine, tool and plant construction, as well as in electronic engineering. Also used in computer systems, scales and in measurement and control technology.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e24 AWG 24C Helukabel Tronic LiYY cable, LiYY PVC data cable, Helukabel LiYY specs, Tronic LiYY cable price, Helukabel signal cable LiYY, 24 AWG 24C LiYY flexible control cable, Helukabel PVC data cable, LiYY multi-core cable, Helukabel LiYY datasheet, 24 AWG 24C  LiYY low voltage cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003c\/strong\u003e\u003cbr\u003e0.14 mm²: 350 V\u003cbr\u003e0.25 - 1.5 mm²: 500 V\u003cbr\u003e(not for high power current installation purposes)\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 1200 V\u003cbr\u003e0.34 - 1.5 mm²: 2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 2400 V\u003cbr\u003e0.34 - 1.5 mm²: 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cbr\u003eat 800 Hz \u003cbr\u003e0.14 - 0.25 mm²: approx. 100 pF\/m\u003cbr\u003e0.34 - 1.5 mm²: approx. 150 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance \u003c\/strong\u003e\u003cbr\u003e78 Ohm,\u003cbr\u003e(approx. value)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003cbr\u003e\u003c\/strong\u003eapprox. 0.65 mH\/km\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 1.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification in alignment with DIN 47100, colour coded without colour repetition from the 45th core\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 24 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e\u003cspan\u003e 24 x 0.25\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 9.8\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e60.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e120.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62728683684209,"sku":"NNC18043","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_d10e6efb-1056-4955-93b1-0bbc91855463.png?v=1764137629"},{"product_id":"24-awg-25c-helukabel-18118-tronic-liyy-pvc-data-cable","title":"24 AWG 25C Helukabel 18118 TRONIC (LiYY) PVC data cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M18001_EN_GB_1.pdf?v=1764135724\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e24 AWG 25C Helukabel 18118 TRONIC (LiYY) PVC data cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. For use where design or constructional measures in the outer diameter require the smallest possible control and signal cables; machine, tool and plant construction, as well as in electronic engineering. Also used in computer systems, scales and in measurement and control technology.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e24 AWG 25C Helukabel Tronic LiYY cable, LiYY PVC data cable, Helukabel LiYY specs, Tronic LiYY cable price, Helukabel signal cable LiYY, 24 AWG 25C LiYY flexible control cable, Helukabel PVC data cable, LiYY multi-core cable, Helukabel LiYY datasheet, 24 AWG 25C  LiYY low voltage cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003c\/strong\u003e\u003cbr\u003e0.14 mm²: 350 V\u003cbr\u003e0.25 - 1.5 mm²: 500 V\u003cbr\u003e(not for high power current installation purposes)\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 1200 V\u003cbr\u003e0.34 - 1.5 mm²: 2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 2400 V\u003cbr\u003e0.34 - 1.5 mm²: 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cbr\u003eat 800 Hz \u003cbr\u003e0.14 - 0.25 mm²: approx. 100 pF\/m\u003cbr\u003e0.34 - 1.5 mm²: approx. 150 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance \u003c\/strong\u003e\u003cbr\u003e78 Ohm,\u003cbr\u003e(approx. value)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003cbr\u003e\u003c\/strong\u003eapprox. 0.65 mH\/km\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 1.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification in alignment with DIN 47100, colour coded without colour repetition from the 45th core\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 24 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e\u003cspan\u003e 25 x 0.25\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 9.8\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e61.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e132.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62728688501105,"sku":"NNC18118","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_d10e6efb-1056-4955-93b1-0bbc91855463.png?v=1764137629"},{"product_id":"24-awg-27c-helukabel-18044-tronic-liyy-pvc-data-cable","title":"24 AWG 27C Helukabel 18044 TRONIC (LiYY) PVC data cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M18001_EN_GB_1.pdf?v=1764135724\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e24 AWG 27C Helukabel 18044 TRONIC (LiYY) PVC data cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. For use where design or constructional measures in the outer diameter require the smallest possible control and signal cables; machine, tool and plant construction, as well as in electronic engineering. Also used in computer systems, scales and in measurement and control technology.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e24 AWG 27C Helukabel Tronic LiYY cable, LiYY PVC data cable, Helukabel LiYY specs, Tronic LiYY cable price, Helukabel signal cable LiYY, 24 AWG 27C LiYY flexible control cable, Helukabel PVC data cable, LiYY multi-core cable, Helukabel LiYY datasheet, 24 AWG 27C  LiYY low voltage cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003c\/strong\u003e\u003cbr\u003e0.14 mm²: 350 V\u003cbr\u003e0.25 - 1.5 mm²: 500 V\u003cbr\u003e(not for high power current installation purposes)\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 1200 V\u003cbr\u003e0.34 - 1.5 mm²: 2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 2400 V\u003cbr\u003e0.34 - 1.5 mm²: 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cbr\u003eat 800 Hz \u003cbr\u003e0.14 - 0.25 mm²: approx. 100 pF\/m\u003cbr\u003e0.34 - 1.5 mm²: approx. 150 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance \u003c\/strong\u003e\u003cbr\u003e78 Ohm,\u003cbr\u003e(approx. value)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003cbr\u003e\u003c\/strong\u003eapprox. 0.65 mH\/km\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 1.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification in alignment with DIN 47100, colour coded without colour repetition from the 45th core\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 24 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e\u003cspan\u003e 27 x 0.25\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 9.8\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e65.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e140.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62728692302193,"sku":"NNC18044","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_d10e6efb-1056-4955-93b1-0bbc91855463.png?v=1764137629"},{"product_id":"24-awg-30c-helukabel-18045-tronic-liyy-pvc-data-cable","title":"24 AWG 30C Helukabel 18045 TRONIC (LiYY) PVC data cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M18001_EN_GB_1.pdf?v=1764135724\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e24 AWG 30C Helukabel 18045 TRONIC (LiYY) PVC data cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. For use where design or constructional measures in the outer diameter require the smallest possible control and signal cables; machine, tool and plant construction, as well as in electronic engineering. Also used in computer systems, scales and in measurement and control technology.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e24 AWG 30C Helukabel Tronic LiYY cable, LiYY PVC data cable, Helukabel LiYY specs, Tronic LiYY cable price, Helukabel signal cable LiYY, 24 AWG 30C LiYY flexible control cable, Helukabel PVC data cable, LiYY multi-core cable, Helukabel LiYY datasheet, 24 AWG 30C  LiYY low voltage cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003c\/strong\u003e\u003cbr\u003e0.14 mm²: 350 V\u003cbr\u003e0.25 - 1.5 mm²: 500 V\u003cbr\u003e(not for high power current installation purposes)\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 1200 V\u003cbr\u003e0.34 - 1.5 mm²: 2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 2400 V\u003cbr\u003e0.34 - 1.5 mm²: 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cbr\u003eat 800 Hz \u003cbr\u003e0.14 - 0.25 mm²: approx. 100 pF\/m\u003cbr\u003e0.34 - 1.5 mm²: approx. 150 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance \u003c\/strong\u003e\u003cbr\u003e78 Ohm,\u003cbr\u003e(approx. value)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003cbr\u003e\u003c\/strong\u003eapprox. 0.65 mH\/km\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 1.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification in alignment with DIN 47100, colour coded without colour repetition from the 45th core\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 24 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e\u003cspan\u003e 30 x 0.25\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 10.3\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e72.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e156.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62728700854641,"sku":"NNC18045","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_d10e6efb-1056-4955-93b1-0bbc91855463.png?v=1764137629"},{"product_id":"24-awg-32c-helukabel-18046-tronic-liyy-pvc-data-cable","title":"24 AWG 32C Helukabel 18046 TRONIC (LiYY) PVC data cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M18001_EN_GB_1.pdf?v=1764135724\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e24 AWG 32C Helukabel 18046 TRONIC (LiYY) PVC data cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. For use where design or constructional measures in the outer diameter require the smallest possible control and signal cables; machine, tool and plant construction, as well as in electronic engineering. Also used in computer systems, scales and in measurement and control technology.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e24 AWG 32C Helukabel Tronic LiYY cable, LiYY PVC data cable, Helukabel LiYY specs, Tronic LiYY cable price, Helukabel signal cable LiYY, 24 AWG 32C LiYY flexible control cable, Helukabel PVC data cable, LiYY multi-core cable, Helukabel LiYY datasheet, 24 AWG 32C  LiYY low voltage cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003c\/strong\u003e\u003cbr\u003e0.14 mm²: 350 V\u003cbr\u003e0.25 - 1.5 mm²: 500 V\u003cbr\u003e(not for high power current installation purposes)\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 1200 V\u003cbr\u003e0.34 - 1.5 mm²: 2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 2400 V\u003cbr\u003e0.34 - 1.5 mm²: 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cbr\u003eat 800 Hz \u003cbr\u003e0.14 - 0.25 mm²: approx. 100 pF\/m\u003cbr\u003e0.34 - 1.5 mm²: approx. 150 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance \u003c\/strong\u003e\u003cbr\u003e78 Ohm,\u003cbr\u003e(approx. value)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003cbr\u003e\u003c\/strong\u003eapprox. 0.65 mH\/km\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 1.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification in alignment with DIN 47100, colour coded without colour repetition from the 45th core\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 24 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e\u003cspan\u003e 32 x 0.25\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 10.9\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e77.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e164.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62728751710577,"sku":"NNC18046","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_d10e6efb-1056-4955-93b1-0bbc91855463.png?v=1764137629"},{"product_id":"24-awg-36c-helukabel-18047-tronic-liyy-pvc-data-cable","title":"24 AWG 36C Helukabel 18047 TRONIC (LiYY) PVC data cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M18001_EN_GB_1.pdf?v=1764135724\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e24 AWG 36C Helukabel 18047 TRONIC (LiYY) PVC data cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. For use where design or constructional measures in the outer diameter require the smallest possible control and signal cables; machine, tool and plant construction, as well as in electronic engineering. Also used in computer systems, scales and in measurement and control technology.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e24 AWG 36C Helukabel Tronic LiYY cable, LiYY PVC data cable, Helukabel LiYY specs, Tronic LiYY cable price, Helukabel signal cable LiYY, 24 AWG 36C LiYY flexible control cable, Helukabel PVC data cable, LiYY multi-core cable, Helukabel LiYY datasheet, 24 AWG 36C  LiYY low voltage cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003c\/strong\u003e\u003cbr\u003e0.14 mm²: 350 V\u003cbr\u003e0.25 - 1.5 mm²: 500 V\u003cbr\u003e(not for high power current installation purposes)\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 1200 V\u003cbr\u003e0.34 - 1.5 mm²: 2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 2400 V\u003cbr\u003e0.34 - 1.5 mm²: 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cbr\u003eat 800 Hz \u003cbr\u003e0.14 - 0.25 mm²: approx. 100 pF\/m\u003cbr\u003e0.34 - 1.5 mm²: approx. 150 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance \u003c\/strong\u003e\u003cbr\u003e78 Ohm,\u003cbr\u003e(approx. value)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003cbr\u003e\u003c\/strong\u003eapprox. 0.65 mH\/km\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 1.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification in alignment with DIN 47100, colour coded without colour repetition from the 45th core\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 24 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e\u003cspan\u003e 36 x 0.25\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 11.3\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e86.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e182.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62728753840497,"sku":"NNC18047","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_d10e6efb-1056-4955-93b1-0bbc91855463.png?v=1764137629"},{"product_id":"24-awg-37c-helukabel-18115-tronic-liyy-pvc-data-cable","title":"24 AWG 37C Helukabel 18115 TRONIC (LiYY) PVC data cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M18001_EN_GB_1.pdf?v=1764135724\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e24 AWG 37C Helukabel 18115 TRONIC (LiYY) PVC data cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. For use where design or constructional measures in the outer diameter require the smallest possible control and signal cables; machine, tool and plant construction, as well as in electronic engineering. Also used in computer systems, scales and in measurement and control technology.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e24 AWG 37C Helukabel Tronic LiYY cable, LiYY PVC data cable, Helukabel LiYY specs, Tronic LiYY cable price, Helukabel signal cable LiYY, 24 AWG 37C LiYY flexible control cable, Helukabel PVC data cable, LiYY multi-core cable, Helukabel LiYY datasheet, 24 AWG 37C  LiYY low voltage cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003c\/strong\u003e\u003cbr\u003e0.14 mm²: 350 V\u003cbr\u003e0.25 - 1.5 mm²: 500 V\u003cbr\u003e(not for high power current installation purposes)\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 1200 V\u003cbr\u003e0.34 - 1.5 mm²: 2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 2400 V\u003cbr\u003e0.34 - 1.5 mm²: 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cbr\u003eat 800 Hz \u003cbr\u003e0.14 - 0.25 mm²: approx. 100 pF\/m\u003cbr\u003e0.34 - 1.5 mm²: approx. 150 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance \u003c\/strong\u003e\u003cbr\u003e78 Ohm,\u003cbr\u003e(approx. value)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003cbr\u003e\u003c\/strong\u003eapprox. 0.65 mH\/km\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 1.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification in alignment with DIN 47100, colour coded without colour repetition from the 45th core\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 24 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e\u003cspan\u003e 37 x 0.25\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 11.3\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e89.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e190.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62728755642737,"sku":"NNC18115","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_d10e6efb-1056-4955-93b1-0bbc91855463.png?v=1764137629"},{"product_id":"24-awg-40c-helukabel-18048-tronic-liyy-pvc-data-cable","title":"24 AWG 40C Helukabel 18048 TRONIC (LiYY) PVC data cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M18001_EN_GB_1.pdf?v=1764135724\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e24 AWG 40C Helukabel 18048 TRONIC (LiYY) PVC data cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. For use where design or constructional measures in the outer diameter require the smallest possible control and signal cables; machine, tool and plant construction, as well as in electronic engineering. Also used in computer systems, scales and in measurement and control technology.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e24 AWG 40C Helukabel Tronic LiYY cable, LiYY PVC data cable, Helukabel LiYY specs, Tronic LiYY cable price, Helukabel signal cable LiYY, 24 AWG 40C LiYY flexible control cable, Helukabel PVC data cable, LiYY multi-core cable, Helukabel LiYY datasheet, 24 AWG 40C  LiYY low voltage cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003c\/strong\u003e\u003cbr\u003e0.14 mm²: 350 V\u003cbr\u003e0.25 - 1.5 mm²: 500 V\u003cbr\u003e(not for high power current installation purposes)\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 1200 V\u003cbr\u003e0.34 - 1.5 mm²: 2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 - 0.25 mm²: 2400 V\u003cbr\u003e0.34 - 1.5 mm²: 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cbr\u003eat 800 Hz \u003cbr\u003e0.14 - 0.25 mm²: approx. 100 pF\/m\u003cbr\u003e0.34 - 1.5 mm²: approx. 150 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance \u003c\/strong\u003e\u003cbr\u003e78 Ohm,\u003cbr\u003e(approx. value)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003cbr\u003e\u003c\/strong\u003eapprox. 0.65 mH\/km\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 1.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification in alignment with DIN 47100, colour coded without colour repetition from the 45th core\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 24 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e\u003cspan\u003e 40 x 0.25\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 12.4\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e96.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e200.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62728759083377,"sku":"NNC18048","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_d10e6efb-1056-4955-93b1-0bbc91855463.png?v=1764137629"}],"url":"https:\/\/nassaunationalcable.com\/en-ca\/collections\/helukabel-tronic-liyy-pvc-data-cable.oembed?page=7","provider":"NassauNationalCable","version":"1.0","type":"link"}