{"title":"HELUKABEL JZ-500 HMH-C \/ OZ-500 HMH-C HIGHLY FLAME RETARDANT CONTROL AND CONNECTION CABLE","description":"","products":[{"product_id":"20-awg-2c-helukabel-11656-oz-500-hmh-c-highly-flame-retardant-control-and-connection-cable","title":"20 AWG 2C Helukabel 11656 OZ-500 HMH-C Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11656_EN_GB_1.pdf?v=1763615242\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 2C Helukabel 11656 OZ-500 HMH-C Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster. The high degree of screening assures an interference-free transmission of signals and pulses. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and allround large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e20 AWG 2C HMH-C control and connection cable. Flame retardant HMH cable for control systems, Flexible control cables HMH-C, HELUKABEL flame retardant control wiring, Flame retardant connection wire, Flame resistant 20 AWG 2C HMH-C cable, OZ-500 HMH-C wire for control, OZ-500 HMH-C connection cable, 20 AWG 2C Highly flame retardant control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363- 7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil\u003cbr\u003e• halogen-free\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332- 3-24 \/ IEC 60332-3-24\u003cbr\u003e• smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034- 1+2 \/ IEC 61034-1+2\u003cbr\u003e• certifications and approvals:\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• cleanroom qualification tested on analog types; please note \"cleanroom qualification\" in your order\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 20 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e\u003cspan\u003e 2 x 0.5\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 5.6\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e35.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e46.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62680761303409,"sku":"NNC11656","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/4-Photoroom_1_-Photoroom.png?v=1763616134"},{"product_id":"20-awg-3c-helukabel-11657-jz-500-hmh-c-highly-flame-retardant-control-and-connection-cable","title":"20 AWG 3C Helukabel 11657 JZ-500 HMH-C Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11656_EN_GB_1.pdf?v=1763615242\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 3C Helukabel 11657 JZ-500 HMH-C Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster. The high degree of screening assures an interference-free transmission of signals and pulses. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and allround large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e20 AWG 3C HMH-C control and connection cable. Flame retardant HMH cable for control systems, Flexible control cables HMH-C, HELUKABEL flame retardant control wiring, Flame retardant connection wire, Flame resistant 20 AWG 3C HMH-C cable, JZ-500 HMH-C wire for control, JZ-500 HMH-C connection cable, 20 AWG 3C Highly flame retardant control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363- 7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil\u003cbr\u003e• halogen-free\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332- 3-24 \/ IEC 60332-3-24\u003cbr\u003e• smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034- 1+2 \/ IEC 61034-1+2\u003cbr\u003e• certifications and approvals:\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• cleanroom qualification tested on analog types; please note \"cleanroom qualification\" in your order\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 20 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e\u003cspan\u003e 3 G 0.5\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 5.9\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e42.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e56.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62680767103345,"sku":"NNC11657","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/4-Photoroom_1_e3323088-b2fc-43a4-bee3-097704ad2580.png?v=1763616817"},{"product_id":"20-awg-3c-helukabel-11342-oz-500-hmh-c-highly-flame-retardant-control-and-connection-cable","title":"20 AWG 3C Helukabel 11342 OZ-500 HMH-C Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11656_EN_GB_1.pdf?v=1763615242\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 3C Helukabel 11342 OZ-500 HMH-C Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster. The high degree of screening assures an interference-free transmission of signals and pulses. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and allround large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e20 AWG 3C HMH-C control and connection cable. Flame retardant HMH cable for control systems, Flexible control cables HMH-C, HELUKABEL flame retardant control wiring, Flame retardant connection wire, Flame resistant 20 AWG 3C HMH-C cable, OZ-500 HMH-C wire for control, OZ-500 HMH-C connection cable, 20 AWG 3C Highly flame retardant control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363- 7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil\u003cbr\u003e• halogen-free\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332- 3-24 \/ IEC 60332-3-24\u003cbr\u003e• smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034- 1+2 \/ IEC 61034-1+2\u003cbr\u003e• certifications and approvals:\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• cleanroom qualification tested on analog types; please note \"cleanroom qualification\" in your order\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 20 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e\u003cspan\u003e 3 x 0.5\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 5.9\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e42.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e56.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62680776868209,"sku":"NNC11342","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/4-Photoroom_1_-Photoroom_3d36f4b8-7809-4afc-939c-8245fd68186b.png?v=1763617037"},{"product_id":"20-awg-4c-helukabel-11658-jz-500-hmh-c-highly-flame-retardant-control-and-connection-cable","title":"20 AWG 4C Helukabel 11658 JZ-500 HMH-C Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11656_EN_GB_1.pdf?v=1763615242\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 4C Helukabel 11658 JZ-500 HMH-C Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster. The high degree of screening assures an interference-free transmission of signals and pulses. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and allround large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e20 AWG 4C HMH-C control and connection cable. Flame retardant HMH cable for control systems, Flexible control cables HMH-C, HELUKABEL flame retardant control wiring, Flame retardant connection wire, Flame resistant 20 AWG 4C HMH-C cable, JZ-500 HMH-C wire for control, JZ-500 HMH-C connection cable, 20 AWG 4C Highly flame retardant control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363- 7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil\u003cbr\u003e• halogen-free\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332- 3-24 \/ IEC 60332-3-24\u003cbr\u003e• smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034- 1+2 \/ IEC 61034-1+2\u003cbr\u003e• certifications and approvals:\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• cleanroom qualification tested on analog types; please note \"cleanroom qualification\" in your order\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 20 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e\u003cspan\u003e 4 G 0.5\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 6.3\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e47.0 \u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e62.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62680782340465,"sku":"NNC11658","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/4-Photoroom_1_e0cb6f83-b89c-46e8-9147-eba61aa5710d.png?v=1763617243"},{"product_id":"20-awg-4c-helukabel-11343-oz-500-hmh-c-highly-flame-retardant-control-and-connection-cable","title":"20 AWG 4C Helukabel 11343 OZ-500 HMH-C Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11656_EN_GB_1.pdf?v=1763615242\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 4C Helukabel 11343 OZ-500 HMH-C Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster. The high degree of screening assures an interference-free transmission of signals and pulses. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and allround large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e20 AWG 4C HMH-C control and connection cable. Flame retardant HMH cable for control systems, Flexible control cables HMH-C, HELUKABEL flame retardant control wiring, Flame retardant connection wire, Flame resistant 20 AWG 4C HMH-C cable, OZ-500 HMH-C wire for control, OZ-500 HMH-C connection cable, 20 AWG 4C Highly flame retardant control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363- 7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil\u003cbr\u003e• halogen-free\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332- 3-24 \/ IEC 60332-3-24\u003cbr\u003e• smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034- 1+2 \/ IEC 61034-1+2\u003cbr\u003e• certifications and approvals:\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• cleanroom qualification tested on analog types; please note \"cleanroom qualification\" in your order\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 20 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e\u003cspan\u003e 4 x 0.5\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 6.3\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e47.0 \u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e62.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62680782635377,"sku":"NNC11343","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/4-Photoroom_1_-Photoroom_8f809c36-0a4f-4021-8511-74d8b7ae2fce.png?v=1763617624"},{"product_id":"20-awg-5c-helukabel-11659-jz-500-hmh-c-highly-flame-retardant-control-and-connection-cable","title":"20 AWG 5C Helukabel 11659 JZ-500 HMH-C Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11656_EN_GB_1.pdf?v=1763615242\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 5C Helukabel 11659 JZ-500 HMH-C Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster. The high degree of screening assures an interference-free transmission of signals and pulses. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and allround large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e20 AWG 5C HMH-C control and connection cable. Flame retardant HMH cable for control systems, Flexible control cables HMH-C, HELUKABEL flame retardant control wiring, Flame retardant connection wire, Flame resistant 20 AWG 5C HMH-C cable, JZ-500 HMH-C wire for control, JZ-500 HMH-C connection cable, 20 AWG 5C Highly flame retardant control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363- 7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil\u003cbr\u003e• halogen-free\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332- 3-24 \/ IEC 60332-3-24\u003cbr\u003e• smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034- 1+2 \/ IEC 61034-1+2\u003cbr\u003e• certifications and approvals:\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• cleanroom qualification tested on analog types; please note \"cleanroom qualification\" in your order\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 20 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e\u003cspan\u003e 5 G 0.5\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 6.8\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e56.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e75.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62680784404849,"sku":"NNC11659","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/4-Photoroom_1_8e015417-3531-4b0f-845e-2c88fa1c53e0.png?v=1763617854"},{"product_id":"20-awg-7c-helukabel-11660-jz-500-hmh-c-highly-flame-retardant-control-and-connection-cable","title":"20 AWG 7C Helukabel 11660 JZ-500 HMH-C Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11656_EN_GB_1.pdf?v=1763615242\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 7C Helukabel 11660 JZ-500 HMH-C Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster. The high degree of screening assures an interference-free transmission of signals and pulses. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and allround large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e20 AWG 7C HMH-C control and connection cable. Flame retardant HMH cable for control systems, Flexible control cables HMH-C, HELUKABEL flame retardant control wiring, Flame retardant connection wire, Flame resistant 20 AWG 7C HMH-C cable, JZ-500 HMH-C wire for control, JZ-500 HMH-C connection cable, 20 AWG 7C Highly flame retardant control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363- 7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil\u003cbr\u003e• halogen-free\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332- 3-24 \/ IEC 60332-3-24\u003cbr\u003e• smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034- 1+2 \/ IEC 61034-1+2\u003cbr\u003e• certifications and approvals:\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• cleanroom qualification tested on analog types; please note \"cleanroom qualification\" in your order\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 20 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e\u003cspan\u003e 7 G 0.5\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 7.3\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e69.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e98.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62680786370929,"sku":"NNC11660","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/4-Photoroom_1_8e015417-3531-4b0f-845e-2c88fa1c53e0.png?v=1763617854"},{"product_id":"20-awg-8c-helukabel-11017510-oz-500-hmh-c-highly-flame-retardant-control-and-connection-cable","title":"20 AWG 8C Helukabel 11017510 OZ-500 HMH-C Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11656_EN_GB_1.pdf?v=1763615242\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 8C Helukabel 11017510 OZ-500 HMH-C Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster. The high degree of screening assures an interference-free transmission of signals and pulses. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and allround large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e20 AWG 8C HMH-C control and connection cable. Flame retardant HMH cable for control systems, Flexible control cables HMH-C, HELUKABEL flame retardant control wiring, Flame retardant connection wire, Flame resistant 20 AWG 8C HMH-C cable, OZ-500 HMH-C wire for control, OZ-500 HMH-C connection cable, 20 AWG 8C Highly flame retardant control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363- 7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil\u003cbr\u003e• halogen-free\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332- 3-24 \/ IEC 60332-3-24\u003cbr\u003e• smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034- 1+2 \/ IEC 61034-1+2\u003cbr\u003e• certifications and approvals:\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• cleanroom qualification tested on analog types; please note \"cleanroom qualification\" in your order\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 20 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e\u003cspan\u003e 8 x 0.5\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 8.0\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e80.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e115.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62680788959601,"sku":"NNC11017510","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/4-Photoroom_1_-Photoroom_cdf39061-733d-46ad-80d5-2fdc2bb228f6.png?v=1763618339"},{"product_id":"20-awg-12c-helukabel-11663-jz-500-hmh-c-highly-flame-retardant-control-and-connection-cable","title":"20 AWG 12C Helukabel 11663 JZ-500 HMH-C Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11656_EN_GB_1.pdf?v=1763615242\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 12C Helukabel 11663 JZ-500 HMH-C Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster. The high degree of screening assures an interference-free transmission of signals and pulses. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and allround large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e20 AWG 12C HMH-C control and connection cable. Flame retardant HMH cable for control systems, Flexible control cables HMH-C, HELUKABEL flame retardant control wiring, Flame retardant connection wire, Flame resistant 20 AWG 12C HMH-C cable, JZ-500 HMH-C wire for control, JZ-500 HMH-C connection cable, 20 AWG 12C Highly flame retardant control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363- 7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil\u003cbr\u003e• halogen-free\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332- 3-24 \/ IEC 60332-3-24\u003cbr\u003e• smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034- 1+2 \/ IEC 61034-1+2\u003cbr\u003e• certifications and approvals:\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• cleanroom qualification tested on analog types; please note \"cleanroom qualification\" in your order\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 20 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² : \u003c\/strong\u003e12 G 0.5\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 9.7\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e108.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e158.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62680792400241,"sku":"NNC11663","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/4-Photoroom_1_ae6cf212-7c99-4240-8670-4d5c42ffd4c8.png?v=1763618657"},{"product_id":"20-awg-18c-helukabel-11665-jz-500-hmh-c-highly-flame-retardant-control-and-connection-cable","title":"20 AWG 18C Helukabel 11665 JZ-500 HMH-C Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11656_EN_GB_1.pdf?v=1763615242\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 18C Helukabel 11665 JZ-500 HMH-C Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster. The high degree of screening assures an interference-free transmission of signals and pulses. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and allround large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e20 AWG 18C HMH-C control and connection cable. Flame retardant HMH cable for control systems, Flexible control cables HMH-C, HELUKABEL flame retardant control wiring, Flame retardant connection wire, Flame resistant 20 AWG 18C HMH-C cable, JZ-500 HMH-C wire for control, JZ-500 HMH-C connection cable, 20 AWG 18C Highly flame retardant control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363- 7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil\u003cbr\u003e• halogen-free\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332- 3-24 \/ IEC 60332-3-24\u003cbr\u003e• smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034- 1+2 \/ IEC 61034-1+2\u003cbr\u003e• certifications and approvals:\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• cleanroom qualification tested on analog types; please note \"cleanroom qualification\" in your order\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 20 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² : \u003c\/strong\u003e18 G 0.5\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 11.3\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e145.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e216.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62680797348209,"sku":"NNC11665","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/4-Photoroom_1_ae6cf212-7c99-4240-8670-4d5c42ffd4c8.png?v=1763618657"},{"product_id":"20-awg-25c-helukabel-11667-jz-500-hmh-c-highly-flame-retardant-control-and-connection-cable","title":"20 AWG 25C Helukabel 11667 JZ-500 HMH-C Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11656_EN_GB_1.pdf?v=1763615242\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 25C Helukabel 11667 JZ-500 HMH-C Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster. The high degree of screening assures an interference-free transmission of signals and pulses. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and allround large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e20 AWG 25C HMH-C control and connection cable. Flame retardant HMH cable for control systems, Flexible control cables HMH-C, HELUKABEL flame retardant control wiring, Flame retardant connection wire, Flame resistant 20 AWG 25C HMH-C cable, JZ-500 HMH-C wire for control, JZ-500 HMH-C connection cable, 20 AWG 25C Highly flame retardant control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363- 7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil\u003cbr\u003e• halogen-free\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332- 3-24 \/ IEC 60332-3-24\u003cbr\u003e• smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034- 1+2 \/ IEC 61034-1+2\u003cbr\u003e• certifications and approvals:\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• cleanroom qualification tested on analog types; please note \"cleanroom qualification\" in your order\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 20 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² : \u003c\/strong\u003e25 G 0.5\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 13.4\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e240.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e315.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62680808489329,"sku":"NNC11667","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/4-Photoroom_1_ae6cf212-7c99-4240-8670-4d5c42ffd4c8.png?v=1763618657"},{"product_id":"19-awg-2c-helukabel-11678-oz-500-hmh-c-highly-flame-retardant-control-and-connection-cable","title":"19 AWG 2C Helukabel 11678 OZ-500 HMH-C Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11656_EN_GB_1.pdf?v=1763615242\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e19 AWG 2C Helukabel 11678 OZ-500 HMH-C Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster. The high degree of screening assures an interference-free transmission of signals and pulses. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and allround large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e19 AWG 2C HMH-C control and connection cable. Flame retardant HMH cable for control systems, Flexible control cables HMH-C, HELUKABEL flame retardant control wiring, Flame retardant connection wire, Flame resistant 19 AWG 2C HMH-C cable, OZ-500 HMH-C wire for control, OZ-500 HMH-C connection cable, 19 AWG 2C Highly flame retardant control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363- 7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil\u003cbr\u003e• halogen-free\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332- 3-24 \/ IEC 60332-3-24\u003cbr\u003e• smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034- 1+2 \/ IEC 61034-1+2\u003cbr\u003e• certifications and approvals:\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• cleanroom qualification tested on analog types; please note \"cleanroom qualification\" in your order\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 19 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² : \u003c\/strong\u003e2 x 0.75\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 6.1\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e40.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e60.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62680876679537,"sku":"NNC11678","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/4-Photoroom_1_-Photoroom_a1078b9a-6a25-43c7-a683-402c9b99b643.png?v=1763620623"},{"product_id":"19-awg-3c-helukabel-11679-jz-500-hmh-c-highly-flame-retardant-control-and-connection-cable","title":"19 AWG 3C Helukabel 11679 JZ-500 HMH-C Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11656_EN_GB_1.pdf?v=1763615242\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e19 AWG 3C Helukabel 11679 JZ-500 HMH-C Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster. The high degree of screening assures an interference-free transmission of signals and pulses. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and allround large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e19 AWG 3C HMH-C control and connection cable. Flame retardant HMH cable for control systems, Flexible control cables HMH-C, HELUKABEL flame retardant control wiring, Flame retardant connection wire, Flame resistant 19 AWG 3C HMH-C cable, JZ-500 HMH-C wire for control, JZ-500 HMH-C connection cable, 19 AWG 3C Highly flame retardant control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363- 7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil\u003cbr\u003e• halogen-free\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332- 3-24 \/ IEC 60332-3-24\u003cbr\u003e• smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034- 1+2 \/ IEC 61034-1+2\u003cbr\u003e• certifications and approvals:\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• cleanroom qualification tested on analog types; please note \"cleanroom qualification\" in your order\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 19 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² : \u003c\/strong\u003e3 G 0.75\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 6.4\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e52.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e68.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62680888050033,"sku":"NNC11679","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/4-Photoroom_1_543d0363-c6ff-4ed5-8b82-357470085f60.png?v=1763621113"},{"product_id":"19-awg-3c-helukabel-11344-oz-500-hmh-c-highly-flame-retardant-control-and-connection-cable","title":"19 AWG 3C Helukabel 11344 OZ-500 HMH-C Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11656_EN_GB_1.pdf?v=1763615242\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e19 AWG 3C Helukabel 11344 OZ-500 HMH-C Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster. The high degree of screening assures an interference-free transmission of signals and pulses. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and allround large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e19 AWG 3C HMH-C control and connection cable. Flame retardant HMH cable for control systems, Flexible control cables HMH-C, HELUKABEL flame retardant control wiring, Flame retardant connection wire, Flame resistant 19 AWG 3C HMH-C cable, 0Z-500 HMH-C wire for control, 0Z-500 HMH-C connection cable, 19 AWG 3C Highly flame retardant control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363- 7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil\u003cbr\u003e• halogen-free\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332- 3-24 \/ IEC 60332-3-24\u003cbr\u003e• smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034- 1+2 \/ IEC 61034-1+2\u003cbr\u003e• certifications and approvals:\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• cleanroom qualification tested on analog types; please note \"cleanroom qualification\" in your order\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 19 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² : \u003c\/strong\u003e3 x 0.75\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 6.4\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e52.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e68.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62680894767473,"sku":"NNC11344","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/4-Photoroom_1_-Photoroom_3743dee0-45a2-4004-a58f-83fdacc89acd.png?v=1763622090"},{"product_id":"19-awg-4c-helukabel-11680-jz-500-hmh-c-highly-flame-retardant-control-and-connection-cable","title":"19 AWG 4C Helukabel 11680 JZ-500 HMH-C Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11656_EN_GB_1.pdf?v=1763615242\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e19 AWG 4C Helukabel 11680 JZ-500 HMH-C Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster. The high degree of screening assures an interference-free transmission of signals and pulses. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and allround large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e19 AWG 4C HMH-C control and connection cable. Flame retardant HMH cable for control systems, Flexible control cables HMH-C, HELUKABEL flame retardant control wiring, Flame retardant connection wire, Flame resistant 19 AWG 4C HMH-C cable, JZ-500 HMH-C wire for control, JZ-500 HMH-C connection cable, 19 AWG 4C Highly flame retardant control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363- 7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil\u003cbr\u003e• halogen-free\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332- 3-24 \/ IEC 60332-3-24\u003cbr\u003e• smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034- 1+2 \/ IEC 61034-1+2\u003cbr\u003e• certifications and approvals:\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• cleanroom qualification tested on analog types; please note \"cleanroom qualification\" in your order\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 19 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² : \u003c\/strong\u003e4 G 0.75\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 6.9\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e60.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e78.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62680895357297,"sku":"NNC11680","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/4-Photoroom_1_236ac8b6-a0e1-4651-b11e-b67702b03447.png?v=1763622369"},{"product_id":"19-awg-4c-helukabel-11345-oz-500-hmh-c-highly-flame-retardant-control-and-connection-cable","title":"19 AWG 4C Helukabel 11345 OZ-500 HMH-C Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11656_EN_GB_1.pdf?v=1763615242\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e19 AWG 4C Helukabel 11345 OZ-500 HMH-C Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster. The high degree of screening assures an interference-free transmission of signals and pulses. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and allround large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e19 AWG 4C HMH-C control and connection cable. Flame retardant HMH cable for control systems, Flexible control cables HMH-C, HELUKABEL flame retardant control wiring, Flame retardant connection wire, Flame resistant 19 AWG 4C HMH-C cable, 0Z-500 HMH-C wire for control, 0Z-500 HMH-C connection cable, 19 AWG 4C Highly flame retardant control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363- 7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil\u003cbr\u003e• halogen-free\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332- 3-24 \/ IEC 60332-3-24\u003cbr\u003e• smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034- 1+2 \/ IEC 61034-1+2\u003cbr\u003e• certifications and approvals:\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• cleanroom qualification tested on analog types; please note \"cleanroom qualification\" in your order\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 19 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² : \u003c\/strong\u003e4 x 0.75 \u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 6.9\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e60.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e78.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62680903549297,"sku":"NNC11345","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/4-Photoroom_1_-Photoroom_dfffc53a-42a5-4e14-856d-5596916a0e64.png?v=1763622649"},{"product_id":"19-awg-5c-helukabel-11681-jz-500-hmh-c-highly-flame-retardant-control-and-connection-cable","title":"19 AWG 5C Helukabel 11681 JZ-500 HMH-C Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11656_EN_GB_1.pdf?v=1763615242\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e19 AWG 5C Helukabel 11681 JZ-500 HMH-C Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster. The high degree of screening assures an interference-free transmission of signals and pulses. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and allround large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e19 AWG 5C HMH-C control and connection cable. Flame retardant HMH cable for control systems, Flexible control cables HMH-C, HELUKABEL flame retardant control wiring, Flame retardant connection wire, Flame resistant 19 AWG 5C HMH-C cable, JZ-500 HMH-C wire for control, JZ-500 HMH-C connection cable, 19 AWG 5C Highly flame retardant control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363- 7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil\u003cbr\u003e• halogen-free\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332- 3-24 \/ IEC 60332-3-24\u003cbr\u003e• smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034- 1+2 \/ IEC 61034-1+2\u003cbr\u003e• certifications and approvals:\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• cleanroom qualification tested on analog types; please note \"cleanroom qualification\" in your order\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 19 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² : \u003c\/strong\u003e5 G 0.75\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 7.5\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e71.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e95.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62680905318769,"sku":"NNC11681","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/4-Photoroom_1_47feedc7-1069-4276-99fc-78bd4303e16a.png?v=1763622960"},{"product_id":"19-awg-5c-helukabel-11346-oz-500-hmh-c-highly-flame-retardant-control-and-connection-cable","title":"19 AWG 5C Helukabel 11346 OZ-500 HMH-C Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11656_EN_GB_1.pdf?v=1763615242\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e19 AWG 5C Helukabel 11346 OZ-500 HMH-C Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster. The high degree of screening assures an interference-free transmission of signals and pulses. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and allround large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e19 AWG 5C HMH-C control and connection cable. Flame retardant HMH cable for control systems, Flexible control cables HMH-C, HELUKABEL flame retardant control wiring, Flame retardant connection wire, Flame resistant 19 AWG 5C HMH-C cable, OZ-500 HMH-C wire for control, OZ-500 HMH-C connection cable, 19 AWG 5C Highly flame retardant control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363- 7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil\u003cbr\u003e• halogen-free\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332- 3-24 \/ IEC 60332-3-24\u003cbr\u003e• smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034- 1+2 \/ IEC 61034-1+2\u003cbr\u003e• certifications and approvals:\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• cleanroom qualification tested on analog types; please note \"cleanroom qualification\" in your order\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 19 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² : \u003c\/strong\u003e5 x 0.75\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 7.5\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e71.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e95.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62680912593265,"sku":"NNC11346","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/4-Photoroom_1_-Photoroom_571c859d-981c-4838-9f3a-c643c9a78140.png?v=1763623180"},{"product_id":"19-awg-7c-helukabel-11682-jz-500-hmh-c-highly-flame-retardant-control-and-connection-cable","title":"19 AWG 7C Helukabel 11682 JZ-500 HMH-C Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11656_EN_GB_1.pdf?v=1763615242\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e19 AWG 7C Helukabel 11682 JZ-500 HMH-C Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster. The high degree of screening assures an interference-free transmission of signals and pulses. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and allround large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e19 AWG 7C HMH-C control and connection cable. Flame retardant HMH cable for control systems, Flexible control cables HMH-C, HELUKABEL flame retardant control wiring, Flame retardant connection wire, Flame resistant 19 AWG 7C HMH-C cable, JZ-500 HMH-C wire for control, JZ-500 HMH-C connection cable, 19 AWG 7C Highly flame retardant control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363- 7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil\u003cbr\u003e• halogen-free\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332- 3-24 \/ IEC 60332-3-24\u003cbr\u003e• smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034- 1+2 \/ IEC 61034-1+2\u003cbr\u003e• certifications and approvals:\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• cleanroom qualification tested on analog types; please note \"cleanroom qualification\" in your order\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 19 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² : \u003c\/strong\u003e7 G 0.75 \u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 8.3\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e91.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e130.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62680913150321,"sku":"NNC11682","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/4-Photoroom_1_ed61330f-9d58-43e6-81ea-7bab1cdea9d1.png?v=1763623456"},{"product_id":"19-awg-7c-helukabel-11347-oz-500-hmh-c-highly-flame-retardant-control-and-connection-cable","title":"19 AWG 7C Helukabel 11347 OZ-500 HMH-C Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11656_EN_GB_1.pdf?v=1763615242\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e19 AWG 7C Helukabel 11347 OZ-500 HMH-C Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster. The high degree of screening assures an interference-free transmission of signals and pulses. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and allround large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e19 AWG 7C HMH-C control and connection cable. Flame retardant HMH cable for control systems, Flexible control cables HMH-C, HELUKABEL flame retardant control wiring, Flame retardant connection wire, Flame resistant 19 AWG 7C HMH-C cable, OZ-500 HMH-C wire for control, OZ-500 HMH-C connection cable, 19 AWG 7C Highly flame retardant control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363- 7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil\u003cbr\u003e• halogen-free\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332- 3-24 \/ IEC 60332-3-24\u003cbr\u003e• smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034- 1+2 \/ IEC 61034-1+2\u003cbr\u003e• certifications and approvals:\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• cleanroom qualification tested on analog types; please note \"cleanroom qualification\" in your order\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 19 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² : \u003c\/strong\u003e7 x 0.75\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 8.3\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e91.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e130.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62680914690417,"sku":"NNC11347","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/4-Photoroom_1_-Photoroom_7ee19a6c-b248-411b-b536-d520d15e1a61.png?v=1763623757"},{"product_id":"19-awg-12c-helukabel-11685-jz-500-hmh-c-highly-flame-retardant-control-and-connection-cable","title":"19 AWG 12C Helukabel 11685 JZ-500 HMH-C Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11656_EN_GB_1.pdf?v=1763615242\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e19 AWG 12C Helukabel 11685 JZ-500 HMH-C Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster. The high degree of screening assures an interference-free transmission of signals and pulses. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and allround large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e19 AWG 12C HMH-C control and connection cable. Flame retardant HMH cable for control systems, Flexible control cables HMH-C, HELUKABEL flame retardant control wiring, Flame retardant connection wire, Flame resistant 19 AWG 12C HMH-C cable, JZ-500 HMH-C wire for control, JZ-500 HMH-C connection cable, 19 AWG 12C Highly flame retardant control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363- 7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil\u003cbr\u003e• halogen-free\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332- 3-24 \/ IEC 60332-3-24\u003cbr\u003e• smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034- 1+2 \/ IEC 61034-1+2\u003cbr\u003e• certifications and approvals:\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• cleanroom qualification tested on analog types; please note \"cleanroom qualification\" in your order\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 19 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² : \u003c\/strong\u003e12 G 0.75\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 10.9\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e142.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e203.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62680915870065,"sku":"NNC11685","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/4-Photoroom_1_64c6ff88-0396-45dd-919d-9268dcd4c75f.png?v=1763623985"},{"product_id":"19-awg-18c-helukabel-11687-jz-500-hmh-c-highly-flame-retardant-control-and-connection-cable","title":"19 AWG 18C Helukabel 11687 JZ-500 HMH-C Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11656_EN_GB_1.pdf?v=1763615242\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e19 AWG 18C Helukabel 11687 JZ-500 HMH-C Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster. The high degree of screening assures an interference-free transmission of signals and pulses. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and allround large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e19 AWG 18C HMH-C control and connection cable. Flame retardant HMH cable for control systems, Flexible control cables HMH-C, HELUKABEL flame retardant control wiring, Flame retardant connection wire, Flame resistant 19 AWG 18C HMH-C cable, JZ-500 HMH-C wire for control, JZ-500 HMH-C connection cable, 19 AWG 18C Highly flame retardant control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363- 7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil\u003cbr\u003e• halogen-free\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332- 3-24 \/ IEC 60332-3-24\u003cbr\u003e• smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034- 1+2 \/ IEC 61034-1+2\u003cbr\u003e• certifications and approvals:\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• cleanroom qualification tested on analog types; please note \"cleanroom qualification\" in your order\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 19 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² : \u003c\/strong\u003e18 G 0.75 \u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 12.8\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e212.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e290.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62680919376241,"sku":"NNC11687","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/4-Photoroom_1_64c6ff88-0396-45dd-919d-9268dcd4c75f.png?v=1763623985"},{"product_id":"19-awg-25c-helukabel-11689-jz-500-hmh-c-highly-flame-retardant-control-and-connection-cable","title":"19 AWG 25C Helukabel 11689 JZ-500 HMH-C Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11656_EN_GB_1.pdf?v=1763615242\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e19 AWG 25C Helukabel 11689 JZ-500 HMH-C Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster. The high degree of screening assures an interference-free transmission of signals and pulses. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and allround large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e19 AWG 25C HMH-C control and connection cable. Flame retardant HMH cable for control systems, Flexible control cables HMH-C, HELUKABEL flame retardant control wiring, Flame retardant connection wire, Flame resistant 19 AWG 25C HMH-C cable, JZ-500 HMH-C wire for control, JZ-500 HMH-C connection cable, 19 AWG 25C Highly flame retardant control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363- 7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil\u003cbr\u003e• halogen-free\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332- 3-24 \/ IEC 60332-3-24\u003cbr\u003e• smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034- 1+2 \/ IEC 61034-1+2\u003cbr\u003e• certifications and approvals:\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• cleanroom qualification tested on analog types; please note \"cleanroom qualification\" in your order\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 19 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² : \u003c\/strong\u003e25 G 0.75\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 15.1 \u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e281.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e413.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62680925503857,"sku":"NNC11689","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/4-Photoroom_1_64c6ff88-0396-45dd-919d-9268dcd4c75f.png?v=1763623985"},{"product_id":"18-awg-2c-helukabel-11700-oz-500-hmh-c-highly-flame-retardant-control-and-connection-cable","title":"18 AWG 2C Helukabel 11700 OZ-500 HMH-C Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11656_EN_GB_1.pdf?v=1763615242\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e18 AWG 2C Helukabel 11700 OZ-500 HMH-C Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster. The high degree of screening assures an interference-free transmission of signals and pulses. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and allround large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e18 AWG 2C HMH-C control and connection cable. Flame retardant HMH cable for control systems, Flexible control cables HMH-C, HELUKABEL flame retardant control wiring, Flame retardant connection wire, Flame resistant 18 AWG 2C HMH-C cable, OZ-500 HMH-C wire for control, OZ-500 HMH-C connection cable, 18 AWG 2C Highly flame retardant control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363- 7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil\u003cbr\u003e• halogen-free\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332- 3-24 \/ IEC 60332-3-24\u003cbr\u003e• smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034- 1+2 \/ IEC 61034-1+2\u003cbr\u003e• certifications and approvals:\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• cleanroom qualification tested on analog types; please note \"cleanroom qualification\" in your order\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 18 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² : \u003c\/strong\u003e2 x 1\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 6.4\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e50.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e66.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62680937496945,"sku":"NNC11700","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/4-Photoroom_1_-Photoroom_933d1761-6592-4908-b20d-84add01d03a3.png?v=1763625093"},{"product_id":"18-awg-3c-helukabel-11701-jz-500-hmh-c-highly-flame-retardant-control-and-connection-cable","title":"18 AWG 3C Helukabel 11701 JZ-500 HMH-C Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11656_EN_GB_1.pdf?v=1763615242\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e18 AWG 3C Helukabel 11701 JZ-500 HMH-C Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster. The high degree of screening assures an interference-free transmission of signals and pulses. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and allround large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e18 AWG 3C HMH-C control and connection cable. Flame retardant HMH cable for control systems, Flexible control cables HMH-C, HELUKABEL flame retardant control wiring, Flame retardant connection wire, Flame resistant 18 AWG 3C HMH-C cable, JZ-500 HMH-C wire for control, JZ-500 HMH-C connection cable, 18 AWG 3C Highly flame retardant control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363- 7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil\u003cbr\u003e• halogen-free\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332- 3-24 \/ IEC 60332-3-24\u003cbr\u003e• smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034- 1+2 \/ IEC 61034-1+2\u003cbr\u003e• certifications and approvals:\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• cleanroom qualification tested on analog types; please note \"cleanroom qualification\" in your order\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 18 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² : \u003c\/strong\u003e3 G 1 \u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 6.8\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e60.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e80.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62680952799601,"sku":"NNC11701","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/4-Photoroom_1_d3463fd5-6478-4b2a-96d4-8270ce49549d.png?v=1763625414"},{"product_id":"18-awg-3c-helukabel-11348-oz-500-hmh-c-highly-flame-retardant-control-and-connection-cable","title":"18 AWG 3C Helukabel 11348 OZ-500 HMH-C Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11656_EN_GB_1.pdf?v=1763615242\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e18 AWG 3C Helukabel 11348 OZ-500 HMH-C Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster. The high degree of screening assures an interference-free transmission of signals and pulses. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and allround large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e18 AWG 3C HMH-C control and connection cable. Flame retardant HMH cable for control systems, Flexible control cables HMH-C, HELUKABEL flame retardant control wiring, Flame retardant connection wire, Flame resistant 18 AWG 3C HMH-C cable, OZ-500 HMH-C wire for control, OZ-500 HMH-C connection cable, 18 AWG 3C Highly flame retardant control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363- 7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil\u003cbr\u003e• halogen-free\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332- 3-24 \/ IEC 60332-3-24\u003cbr\u003e• smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034- 1+2 \/ IEC 61034-1+2\u003cbr\u003e• certifications and approvals:\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• cleanroom qualification tested on analog types; please note \"cleanroom qualification\" in your order\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 18 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² : \u003c\/strong\u003e3 x 1\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 6.8\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e60.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e80.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62680965251441,"sku":"NNC11348","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/4-Photoroom_1_-Photoroom_f882facf-3466-4fa4-befa-5fae91feef9e.png?v=1763625644"},{"product_id":"18-awg-4c-helukabel-11702-jz-500-hmh-c-highly-flame-retardant-control-and-connection-cable","title":"18 AWG 4C Helukabel 11702 JZ-500 HMH-C Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11656_EN_GB_1.pdf?v=1763615242\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e18 AWG 4C Helukabel 11702 JZ-500 HMH-C Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster. The high degree of screening assures an interference-free transmission of signals and pulses. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and allround large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e18 AWG 4C HMH-C control and connection cable. Flame retardant HMH cable for control systems, Flexible control cables HMH-C, HELUKABEL flame retardant control wiring, Flame retardant connection wire, Flame resistant 18 AWG 4C HMH-C cable, JZ-500 HMH-C wire for control, JZ-500 HMH-C connection cable, 18 AWG 4C Highly flame retardant control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363- 7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil\u003cbr\u003e• halogen-free\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332- 3-24 \/ IEC 60332-3-24\u003cbr\u003e• smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034- 1+2 \/ IEC 61034-1+2\u003cbr\u003e• certifications and approvals:\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• cleanroom qualification tested on analog types; please note \"cleanroom qualification\" in your order\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 18 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² : \u003c\/strong\u003e4 G 1\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 7.3\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e71.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e100.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62680979472753,"sku":"NNC11702","price":1.58,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/4-Photoroom_1_07b1a3a5-7f04-45ce-8734-f1bab3d081e4.png?v=1763625931"},{"product_id":"18-awg-4c-helukabel-11349-oz-500-hmh-c-highly-flame-retardant-control-and-connection-cable","title":"18 AWG 4C Helukabel 11349 OZ-500 HMH-C Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11656_EN_GB_1.pdf?v=1763615242\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e18 AWG 4C Helukabel 11349 OZ-500 HMH-C Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster. The high degree of screening assures an interference-free transmission of signals and pulses. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and allround large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e18 AWG 4C HMH-C control and connection cable. Flame retardant HMH cable for control systems, Flexible control cables HMH-C, HELUKABEL flame retardant control wiring, Flame retardant connection wire, Flame resistant 18 AWG 4C HMH-C cable, OZ-500 HMH-C wire for control, OZ-500 HMH-C connection cable, 18 AWG 4C Highly flame retardant control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363- 7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil\u003cbr\u003e• halogen-free\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332- 3-24 \/ IEC 60332-3-24\u003cbr\u003e• smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034- 1+2 \/ IEC 61034-1+2\u003cbr\u003e• certifications and approvals:\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• cleanroom qualification tested on analog types; please note \"cleanroom qualification\" in your order\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 18 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² : \u003c\/strong\u003e4 x 1\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 7.3\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e71.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e100.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62680991629681,"sku":"NNC11349","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/4-Photoroom_1_-Photoroom_2c690a5e-3329-473e-8420-551df6460d5d.png?v=1763626164"},{"product_id":"18-awg-5c-helukabel-11703-jz-500-hmh-c-highly-flame-retardant-control-and-connection-cable","title":"18 AWG 5C Helukabel 11703 JZ-500 HMH-C Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11656_EN_GB_1.pdf?v=1763615242\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e18 AWG 5C Helukabel 11703 JZ-500 HMH-C Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster. The high degree of screening assures an interference-free transmission of signals and pulses. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and allround large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e18 AWG 5C HMH-C control and connection cable. Flame retardant HMH cable for control systems, Flexible control cables HMH-C, HELUKABEL flame retardant control wiring, Flame retardant connection wire, Flame resistant 18 AWG 5C HMH-C cable, JZ-500 HMH-C wire for control, JZ-500 HMH-C connection cable, 18 AWG 5C Highly flame retardant control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363- 7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil\u003cbr\u003e• halogen-free\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332- 3-24 \/ IEC 60332-3-24\u003cbr\u003e• smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034- 1+2 \/ IEC 61034-1+2\u003cbr\u003e• certifications and approvals:\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• cleanroom qualification tested on analog types; please note \"cleanroom qualification\" in your order\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 18 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² : \u003c\/strong\u003e5 G 1\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 8.1\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e88.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e130.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62680999592305,"sku":"NNC11703","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/4-Photoroom_1_9d9bfbb5-7c55-4b9d-b9fc-abd4e1dd6ad6.png?v=1763626419"},{"product_id":"18-awg-7c-helukabel-11704-jz-500-hmh-c-highly-flame-retardant-control-and-connection-cable","title":"18 AWG 7C Helukabel 11704 JZ-500 HMH-C Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11656_EN_GB_1.pdf?v=1763615242\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e18 AWG 7C Helukabel 11704 JZ-500 HMH-C Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster. The high degree of screening assures an interference-free transmission of signals and pulses. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and allround large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e18 AWG 7C HMH-C control and connection cable. Flame retardant HMH cable for control systems, Flexible control cables HMH-C, HELUKABEL flame retardant control wiring, Flame retardant connection wire, Flame resistant 18 AWG 7C HMH-C cable, JZ-500 HMH-C wire for control, JZ-500 HMH-C connection cable, 18 AWG 7C Highly flame retardant control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363- 7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil\u003cbr\u003e• halogen-free\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332- 3-24 \/ IEC 60332-3-24\u003cbr\u003e• smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034- 1+2 \/ IEC 61034-1+2\u003cbr\u003e• certifications and approvals:\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• cleanroom qualification tested on analog types; please note \"cleanroom qualification\" in your order\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 18 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² : \u003c\/strong\u003e7 G 1 \u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 8.7\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e111.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e160.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62681004343665,"sku":"NNC11704","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/4-Photoroom_1_9d9bfbb5-7c55-4b9d-b9fc-abd4e1dd6ad6.png?v=1763626419"},{"product_id":"18-awg-12c-helukabel-11707-jz-500-hmh-c-highly-flame-retardant-control-and-connection-cable","title":"18 AWG 12C Helukabel 11707 JZ-500 HMH-C Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11656_EN_GB_1.pdf?v=1763615242\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e18 AWG 12C Helukabel 11707 JZ-500 HMH-C Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster. The high degree of screening assures an interference-free transmission of signals and pulses. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and allround large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e18 AWG 12C HMH-C control and connection cable. Flame retardant HMH cable for control systems, Flexible control cables HMH-C, HELUKABEL flame retardant control wiring, Flame retardant connection wire, Flame resistant 18 AWG 12C HMH-C cable, JZ-500 HMH-C wire for control, JZ-500 HMH-C connection cable, 18 AWG 12C Highly flame retardant control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363- 7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil\u003cbr\u003e• halogen-free\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332- 3-24 \/ IEC 60332-3-24\u003cbr\u003e• smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034- 1+2 \/ IEC 61034-1+2\u003cbr\u003e• certifications and approvals:\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• cleanroom qualification tested on analog types; please note \"cleanroom qualification\" in your order\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 18 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² : \u003c\/strong\u003e12 G 1\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 11.6\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e184.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e260.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62681013911921,"sku":"NNC11707","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/4-Photoroom_1_9d9bfbb5-7c55-4b9d-b9fc-abd4e1dd6ad6.png?v=1763626419"},{"product_id":"18-awg-18c-helukabel-11709-jz-500-hmh-c-highly-flame-retardant-control-and-connection-cable","title":"18 AWG 18C Helukabel 11709 JZ-500 HMH-C Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11656_EN_GB_1.pdf?v=1763615242\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e18 AWG 18C Helukabel 11709 JZ-500 HMH-C Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster. The high degree of screening assures an interference-free transmission of signals and pulses. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and allround large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e18 AWG 18C HMH-C control and connection cable. Flame retardant HMH cable for control systems, Flexible control cables HMH-C, HELUKABEL flame retardant control wiring, Flame retardant connection wire, Flame resistant 18 AWG 18C HMH-C cable, JZ-500 HMH-C wire for control, JZ-500 HMH-C connection cable, 18 AWG 18C Highly flame retardant control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363- 7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil\u003cbr\u003e• halogen-free\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332- 3-24 \/ IEC 60332-3-24\u003cbr\u003e• smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034- 1+2 \/ IEC 61034-1+2\u003cbr\u003e• certifications and approvals:\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• cleanroom qualification tested on analog types; please note \"cleanroom qualification\" in your order\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 18 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² : \u003c\/strong\u003e18 G 1\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 13.7\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e260.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e382.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62681016664433,"sku":"NNC11709","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/4-Photoroom_1_9d9bfbb5-7c55-4b9d-b9fc-abd4e1dd6ad6.png?v=1763626419"},{"product_id":"18-awg-25c-helukabel-11711-jz-500-hmh-c-highly-flame-retardant-control-and-connection-cable","title":"18 AWG 25C Helukabel 11711 JZ-500 HMH-C Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11656_EN_GB_1.pdf?v=1763615242\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e18 AWG 25C Helukabel 11711 JZ-500 HMH-C Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster. The high degree of screening assures an interference-free transmission of signals and pulses. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and allround large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e18 AWG 25C HMH-C control and connection cable. Flame retardant HMH cable for control systems, Flexible control cables HMH-C, HELUKABEL flame retardant control wiring, Flame retardant connection wire, Flame resistant 18 AWG 25C HMH-C cable, JZ-500 HMH-C wire for control, JZ-500 HMH-C connection cable, 18 AWG 25C Highly flame retardant control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363- 7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil\u003cbr\u003e• halogen-free\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332- 3-24 \/ IEC 60332-3-24\u003cbr\u003e• smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034- 1+2 \/ IEC 61034-1+2\u003cbr\u003e• certifications and approvals:\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• cleanroom qualification tested on analog types; please note \"cleanroom qualification\" in your order\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 18 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² : \u003c\/strong\u003e25 G 1\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 16.2\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e349.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e540.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62681024561521,"sku":"NNC11711","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/4-Photoroom_1_9d9bfbb5-7c55-4b9d-b9fc-abd4e1dd6ad6.png?v=1763626419"},{"product_id":"16-awg-2c-helukabel-11722-oz-500-hmh-c-highly-flame-retardant-control-and-connection-cable","title":"16 AWG 2C Helukabel 11722 OZ-500 HMH-C Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11656_EN_GB_1.pdf?v=1763615242\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e16 AWG 2C Helukabel 11722 OZ-500 HMH-C Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster. The high degree of screening assures an interference-free transmission of signals and pulses. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and allround large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e16 AWG 2C HMH-C control and connection cable. Flame retardant HMH cable for control systems, Flexible control cables HMH-C, HELUKABEL flame retardant control wiring, Flame retardant connection wire, Flame resistant 16 AWG 2C HMH-C cable, OZ-500 HMH-C wire for control, OZ-500 HMH-C connection cable, 16 AWG 2C Highly flame retardant control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363- 7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil\u003cbr\u003e• halogen-free\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332- 3-24 \/ IEC 60332-3-24\u003cbr\u003e• smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034- 1+2 \/ IEC 61034-1+2\u003cbr\u003e• certifications and approvals:\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• cleanroom qualification tested on analog types; please note \"cleanroom qualification\" in your order\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 16 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² : \u003c\/strong\u003e2 x 1.5\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 7.0\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e63.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e88.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62681025249649,"sku":"NNC11722","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/4-Photoroom_1_-Photoroom_df4ef81b-d646-4969-9650-c3a4504ddaed.png?v=1763627659"},{"product_id":"16-awg-3c-helukabel-11723-jz-500-hmh-c-highly-flame-retardant-control-and-connection-cable","title":"16 AWG 3C Helukabel 11723 JZ-500 HMH-C Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11656_EN_GB_1.pdf?v=1763615242\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e16 AWG 3C Helukabel 11723 JZ-500 HMH-C Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster. The high degree of screening assures an interference-free transmission of signals and pulses. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and allround large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e16 AWG 3C HMH-C control and connection cable. Flame retardant HMH cable for control systems, Flexible control cables HMH-C, HELUKABEL flame retardant control wiring, Flame retardant connection wire, Flame resistant 16 AWG 3C HMH-C cable, JZ-500 HMH-C wire for control, JZ-500 HMH-C connection cable, 16 AWG 3C Highly flame retardant control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363- 7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil\u003cbr\u003e• halogen-free\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332- 3-24 \/ IEC 60332-3-24\u003cbr\u003e• smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034- 1+2 \/ IEC 61034-1+2\u003cbr\u003e• certifications and approvals:\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• cleanroom qualification tested on analog types; please note \"cleanroom qualification\" in your order\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 16 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² : \u003c\/strong\u003e3 G 1.5\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 7.4\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e80.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e100.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62681027281265,"sku":"NNC11723","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/4-Photoroom_1_a0003ec1-d0e6-4d79-abe9-19a59c88583c.png?v=1763627857"},{"product_id":"16-awg-3c-helukabel-11350-oz-500-hmh-c-highly-flame-retardant-control-and-connection-cable","title":"16 AWG 3C Helukabel 11350 OZ-500 HMH-C Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11656_EN_GB_1.pdf?v=1763615242\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e16 AWG 3C Helukabel 11350 OZ-500 HMH-C Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster. The high degree of screening assures an interference-free transmission of signals and pulses. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and allround large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e16 AWG 3C HMH-C control and connection cable. Flame retardant HMH cable for control systems, Flexible control cables HMH-C, HELUKABEL flame retardant control wiring, Flame retardant connection wire, Flame resistant 16 AWG 3C HMH-C cable, OZ-500 HMH-C wire for control, OZ-500 HMH-C connection cable, 16 AWG 3C Highly flame retardant control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363- 7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil\u003cbr\u003e• halogen-free\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332- 3-24 \/ IEC 60332-3-24\u003cbr\u003e• smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034- 1+2 \/ IEC 61034-1+2\u003cbr\u003e• certifications and approvals:\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• cleanroom qualification tested on analog types; please note \"cleanroom qualification\" in your order\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 16 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e 3 x 1.5 \u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 7.4\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e80.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e100.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62681027838321,"sku":"NNC11350","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/4-Photoroom_1_-Photoroom_3610c248-259f-40c0-a0a1-2ded145580b2.png?v=1763628047"},{"product_id":"16-awg-4c-helukabel-11724-jz-500-hmh-c-highly-flame-retardant-control-and-connection-cable","title":"16 AWG 4C Helukabel 11724 JZ-500 HMH-C Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11656_EN_GB_1.pdf?v=1763615242\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e16 AWG 4C Helukabel 11724 JZ-500 HMH-C Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster. The high degree of screening assures an interference-free transmission of signals and pulses. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and allround large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e16 AWG 4C HMH-C control and connection cable. Flame retardant HMH cable for control systems, Flexible control cables HMH-C, HELUKABEL flame retardant control wiring, Flame retardant connection wire, Flame resistant 16 AWG 4C HMH-C cable, JZ-500 HMH-C wire for control, JZ-500 HMH-C connection cable, 16 AWG 4C Highly flame retardant control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363- 7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil\u003cbr\u003e• halogen-free\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332- 3-24 \/ IEC 60332-3-24\u003cbr\u003e• smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034- 1+2 \/ IEC 61034-1+2\u003cbr\u003e• certifications and approvals:\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• cleanroom qualification tested on analog types; please note \"cleanroom qualification\" in your order\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 16 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e 4 G 1.5\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 8.2\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e97.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e125.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62681028690289,"sku":"NNC11724","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/4-Photoroom_1_616182ba-731b-4238-b1bf-06f0fcca18da.png?v=1763628262"},{"product_id":"16-awg-5c-helukabel-11725-jz-500-hmh-c-highly-flame-retardant-control-and-connection-cable","title":"16 AWG 5C Helukabel 11725 JZ-500 HMH-C Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11656_EN_GB_1.pdf?v=1763615242\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e16 AWG 5C Helukabel 11725 JZ-500 HMH-C Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster. The high degree of screening assures an interference-free transmission of signals and pulses. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and allround large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e16 AWG 5C HMH-C control and connection cable. Flame retardant HMH cable for control systems, Flexible control cables HMH-C, HELUKABEL flame retardant control wiring, Flame retardant connection wire, Flame resistant 16 AWG 5C HMH-C cable, JZ-500 HMH-C wire for control, JZ-500 HMH-C connection cable, 16 AWG 5C Highly flame retardant control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363- 7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil\u003cbr\u003e• halogen-free\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332- 3-24 \/ IEC 60332-3-24\u003cbr\u003e• smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034- 1+2 \/ IEC 61034-1+2\u003cbr\u003e• certifications and approvals:\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• cleanroom qualification tested on analog types; please note \"cleanroom qualification\" in your order\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 16 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e 5 G 1.5\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 8.9\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e119.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e158.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62681031737713,"sku":"NNC11725","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/4-Photoroom_1_616182ba-731b-4238-b1bf-06f0fcca18da.png?v=1763628262"},{"product_id":"16-awg-7c-helukabel-11726-jz-500-hmh-c-highly-flame-retardant-control-and-connection-cable","title":"16 AWG 7C Helukabel 11726 JZ-500 HMH-C Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11656_EN_GB_1.pdf?v=1763615242\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e16 AWG 7C Helukabel 11726 JZ-500 HMH-C Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster. The high degree of screening assures an interference-free transmission of signals and pulses. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and allround large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e16 AWG 7C HMH-C control and connection cable. Flame retardant HMH cable for control systems, Flexible control cables HMH-C, HELUKABEL flame retardant control wiring, Flame retardant connection wire, Flame resistant 16 AWG 7C HMH-C cable, JZ-500 HMH-C wire for control, JZ-500 HMH-C connection cable, 16 AWG 7C Highly flame retardant control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363- 7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil\u003cbr\u003e• halogen-free\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332- 3-24 \/ IEC 60332-3-24\u003cbr\u003e• smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034- 1+2 \/ IEC 61034-1+2\u003cbr\u003e• certifications and approvals:\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• cleanroom qualification tested on analog types; please note \"cleanroom qualification\" in your order\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 16 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e 7 G 1.5\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 9.8\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e147.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e210.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62681032687985,"sku":"NNC11726","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/4-Photoroom_1_616182ba-731b-4238-b1bf-06f0fcca18da.png?v=1763628262"},{"product_id":"16-awg-12c-helukabel-11729-jz-500-hmh-c-highly-flame-retardant-control-and-connection-cable","title":"16 AWG 12C Helukabel 11729 JZ-500 HMH-C Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11656_EN_GB_1.pdf?v=1763615242\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e16 AWG 12C Helukabel 11729 JZ-500 HMH-C Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster. The high degree of screening assures an interference-free transmission of signals and pulses. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and allround large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e16 AWG 12C HMH-C control and connection cable. Flame retardant HMH cable for control systems, Flexible control cables HMH-C, HELUKABEL flame retardant control wiring, Flame retardant connection wire, Flame resistant 16 AWG 12C HMH-C cable, JZ-500 HMH-C wire for control, JZ-500 HMH-C connection cable, 16 AWG 12C Highly flame retardant control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363- 7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil\u003cbr\u003e• halogen-free\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332- 3-24 \/ IEC 60332-3-24\u003cbr\u003e• smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034- 1+2 \/ IEC 61034-1+2\u003cbr\u003e• certifications and approvals:\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• cleanroom qualification tested on analog types; please note \"cleanroom qualification\" in your order\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 16 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e 12 G 1.5\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 13.2\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e267.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e340.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62681035145585,"sku":"NNC11729","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/4-Photoroom_1_616182ba-731b-4238-b1bf-06f0fcca18da.png?v=1763628262"},{"product_id":"16-awg-18c-helukabel-11731-jz-500-hmh-c-highly-flame-retardant-control-and-connection-cable","title":"16 AWG 18C Helukabel 11731 JZ-500 HMH-C Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11656_EN_GB_1.pdf?v=1763615242\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e16 AWG 18C Helukabel 11731 JZ-500 HMH-C Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster. The high degree of screening assures an interference-free transmission of signals and pulses. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and allround large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e16 AWG 18C HMH-C control and connection cable. Flame retardant HMH cable for control systems, Flexible control cables HMH-C, HELUKABEL flame retardant control wiring, Flame retardant connection wire, Flame resistant 16 AWG 18C HMH-C cable, JZ-500 HMH-C wire for control, JZ-500 HMH-C connection cable, 16 AWG 18C Highly flame retardant control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363- 7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil\u003cbr\u003e• halogen-free\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332- 3-24 \/ IEC 60332-3-24\u003cbr\u003e• smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034- 1+2 \/ IEC 61034-1+2\u003cbr\u003e• certifications and approvals:\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• cleanroom qualification tested on analog types; please note \"cleanroom qualification\" in your order\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 16 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e 18 G 1.5 \u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 15.6\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e374.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e480.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62681035243889,"sku":"NNC11731","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/4-Photoroom_1_616182ba-731b-4238-b1bf-06f0fcca18da.png?v=1763628262"},{"product_id":"16-awg-25c-helukabel-11733-jz-500-hmh-c-highly-flame-retardant-control-and-connection-cable","title":"16 AWG 25C Helukabel 11733 JZ-500 HMH-C Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11656_EN_GB_1.pdf?v=1763615242\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e16 AWG 25C Helukabel 11733 JZ-500 HMH-C Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster. The high degree of screening assures an interference-free transmission of signals and pulses. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and allround large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e16 AWG 25C HMH-C control and connection cable. Flame retardant HMH cable for control systems, Flexible control cables HMH-C, HELUKABEL flame retardant control wiring, Flame retardant connection wire, Flame resistant 16 AWG 25C HMH-C cable, JZ-500 HMH-C wire for control, JZ-500 HMH-C connection cable, 16 AWG 25C Highly flame retardant control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363- 7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil\u003cbr\u003e• halogen-free\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332- 3-24 \/ IEC 60332-3-24\u003cbr\u003e• smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034- 1+2 \/ IEC 61034-1+2\u003cbr\u003e• certifications and approvals:\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• cleanroom qualification tested on analog types; please note \"cleanroom qualification\" in your order\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 16 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e 25 G 1.5\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 18.2\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e526.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e702.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62681035276657,"sku":"NNC11733","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/4-Photoroom_1_616182ba-731b-4238-b1bf-06f0fcca18da.png?v=1763628262"},{"product_id":"14-awg-2c-helukabel-11744-oz-500-hmh-c-highly-flame-retardant-control-and-connection-cable","title":"14 AWG 2C Helukabel 11744 OZ-500 HMH-C Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11656_EN_GB_1.pdf?v=1763615242\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 2C Helukabel 11744 OZ-500 HMH-C Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster. The high degree of screening assures an interference-free transmission of signals and pulses. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and allround large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e14 AWG 2C HMH-C control and connection cable. Flame retardant HMH cable for control systems, Flexible control cables HMH-C, HELUKABEL flame retardant control wiring, Flame retardant connection wire, Flame resistant 14 AWG 2C HMH-C cable, OZ-500 HMH-C wire for control, OZ-500 HMH-C connection cable, 14 AWG 2C Highly flame retardant control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363- 7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil\u003cbr\u003e• halogen-free\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332- 3-24 \/ IEC 60332-3-24\u003cbr\u003e• smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034- 1+2 \/ IEC 61034-1+2\u003cbr\u003e• certifications and approvals:\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• cleanroom qualification tested on analog types; please note \"cleanroom qualification\" in your order\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 14 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e 2 x 2.5\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 8.4\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e96.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e132.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62681037209969,"sku":"NNC11744","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/2_a0761e17-2b21-4e8e-a1c8-0baf37356f48.png?v=1763703852"},{"product_id":"14-awg-3c-helukabel-11745-jz-500-hmh-c-highly-flame-retardant-control-and-connection-cable","title":"14 AWG 3C Helukabel 11745 JZ-500 HMH-C Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11656_EN_GB_1.pdf?v=1763615242\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 3C Helukabel 11745 JZ-500 HMH-C Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster. The high degree of screening assures an interference-free transmission of signals and pulses. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and allround large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e14 AWG 3C HMH-C control and connection cable. Flame retardant HMH cable for control systems, Flexible control cables HMH-C, HELUKABEL flame retardant control wiring, Flame retardant connection wire, Flame resistant 14 AWG 3C HMH-C cable, JZ-500 HMH-C wire for control, JZ-500 HMH-C connection cable, 14 AWG 3C Highly flame retardant control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363- 7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil\u003cbr\u003e• halogen-free\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332- 3-24 \/ IEC 60332-3-24\u003cbr\u003e• smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034- 1+2 \/ IEC 61034-1+2\u003cbr\u003e• certifications and approvals:\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• cleanroom qualification tested on analog types; please note \"cleanroom qualification\" in your order\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 14 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e 3 G 2.5\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 8.9\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e144.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e168.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62681037635953,"sku":"NNC11745","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/4-Photoroom_1_db96c68c-f47a-4873-ba59-de28994d2c26.png?v=1763629849"},{"product_id":"14-awg-4c-helukabel-11746-jz-500-hmh-c-highly-flame-retardant-control-and-connection-cable","title":"14 AWG 4C Helukabel 11746 JZ-500 HMH-C Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11656_EN_GB_1.pdf?v=1763615242\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 4C Helukabel 11746 JZ-500 HMH-C Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster. The high degree of screening assures an interference-free transmission of signals and pulses. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and allround large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e14 AWG 4C HMH-C control and connection cable. Flame retardant HMH cable for control systems, Flexible control cables HMH-C, HELUKABEL flame retardant control wiring, Flame retardant connection wire, Flame resistant 14 AWG 4C HMH-C cable, JZ-500 HMH-C wire for control, JZ-500 HMH-C connection cable, 14 AWG 4C Highly flame retardant control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363- 7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil\u003cbr\u003e• halogen-free\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332- 3-24 \/ IEC 60332-3-24\u003cbr\u003e• smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034- 1+2 \/ IEC 61034-1+2\u003cbr\u003e• certifications and approvals:\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• cleanroom qualification tested on analog types; please note \"cleanroom qualification\" in your order\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 14 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e 4 G 2.5\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 9.9\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e148.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e195.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62681039438193,"sku":"NNC11746","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/4-Photoroom_1_db96c68c-f47a-4873-ba59-de28994d2c26.png?v=1763629849"},{"product_id":"14-awg-5c-helukabel-11747-jz-500-hmh-c-highly-flame-retardant-control-and-connection-cable","title":"14 AWG 5C Helukabel 11747 JZ-500 HMH-C Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11656_EN_GB_1.pdf?v=1763615242\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 5C Helukabel 11747 JZ-500 HMH-C Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster. The high degree of screening assures an interference-free transmission of signals and pulses. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and allround large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e14 AWG 5C HMH-C control and connection cable. Flame retardant HMH cable for control systems, Flexible control cables HMH-C, HELUKABEL flame retardant control wiring, Flame retardant connection wire, Flame resistant 14 AWG 5C HMH-C cable, JZ-500 HMH-C wire for control, JZ-500 HMH-C connection cable, 14 AWG 5C Highly flame retardant control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363- 7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil\u003cbr\u003e• halogen-free\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332- 3-24 \/ IEC 60332-3-24\u003cbr\u003e• smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034- 1+2 \/ IEC 61034-1+2\u003cbr\u003e• certifications and approvals:\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• cleanroom qualification tested on analog types; please note \"cleanroom qualification\" in your order\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 14 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e 5 G 2.5\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 10.9\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e181.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e222.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62681040028017,"sku":"NNC11747","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/4-Photoroom_1_db96c68c-f47a-4873-ba59-de28994d2c26.png?v=1763629849"},{"product_id":"14-awg-7c-helukabel-11748-jz-500-hmh-c-highly-flame-retardant-control-and-connection-cable","title":"14 AWG 7C Helukabel 11748 JZ-500 HMH-C Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11656_EN_GB_1.pdf?v=1763615242\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 7C Helukabel 11748 JZ-500 HMH-C Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster. The high degree of screening assures an interference-free transmission of signals and pulses. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and allround large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e14 AWG 7C HMH-C control and connection cable. Flame retardant HMH cable for control systems, Flexible control cables HMH-C, HELUKABEL flame retardant control wiring, Flame retardant connection wire, Flame resistant 14 AWG 7C HMH-C cable, JZ-500 HMH-C wire for control, JZ-500 HMH-C connection cable, 14 AWG 7C Highly flame retardant control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363- 7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil\u003cbr\u003e• halogen-free\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332- 3-24 \/ IEC 60332-3-24\u003cbr\u003e• smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034- 1+2 \/ IEC 61034-1+2\u003cbr\u003e• certifications and approvals:\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• cleanroom qualification tested on analog types; please note \"cleanroom qualification\" in your order\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 14 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e 7 G 2.5\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 11.8\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e255.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e345.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62681112609137,"sku":"NNC11748","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/4-Photoroom_1_db96c68c-f47a-4873-ba59-de28994d2c26.png?v=1763629849"},{"product_id":"14-awg-12c-helukabel-11751-jz-500-hmh-c-highly-flame-retardant-control-and-connection-cable","title":"14 AWG 12C Helukabel 11751 JZ-500 HMH-C Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11656_EN_GB_1.pdf?v=1763615242\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 12C Helukabel 11751 JZ-500 HMH-C Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster. The high degree of screening assures an interference-free transmission of signals and pulses. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and allround large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e14 AWG 12C HMH-C control and connection cable. Flame retardant HMH cable for control systems, Flexible control cables HMH-C, HELUKABEL flame retardant control wiring, Flame retardant connection wire, Flame resistant 14 AWG 12C HMH-C cable, JZ-500 HMH-C wire for control, JZ-500 HMH-C connection cable, 14 AWG 12C Highly flame retardant control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363- 7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil\u003cbr\u003e• halogen-free\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332- 3-24 \/ IEC 60332-3-24\u003cbr\u003e• smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034- 1+2 \/ IEC 61034-1+2\u003cbr\u003e• certifications and approvals:\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• cleanroom qualification tested on analog types; please note \"cleanroom qualification\" in your order\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 14 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e 12 G 2.5\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 16.1\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e441.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e572.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62681115853169,"sku":"NNC11751","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/4-Photoroom_1_db96c68c-f47a-4873-ba59-de28994d2c26.png?v=1763629849"},{"product_id":"12-awg-2c-helukabel-11766-oz-500-hmh-c-highly-flame-retardant-control-and-connection-cable","title":"12 AWG 2C Helukabel 11766 OZ-500 HMH-C Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11656_EN_GB_1.pdf?v=1763615242\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 2C Helukabel 11766 OZ-500 HMH-C Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster. The high degree of screening assures an interference-free transmission of signals and pulses. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and allround large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e12 AWG 2C  HMH-C control and connection cable. Flame retardant HMH cable for control systems, Flexible control cables HMH-C, HELUKABEL flame retardant control wiring, Flame retardant connection wire, Flame resistant 12 AWG 2C  HMH-C cable, OZ-500 HMH-C wire for control, OZ-500 HMH-C connection cable, 12 AWG 2C Highly flame retardant control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363- 7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil\u003cbr\u003e• halogen-free\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332- 3-24 \/ IEC 60332-3-24\u003cbr\u003e• smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034- 1+2 \/ IEC 61034-1+2\u003cbr\u003e• certifications and approvals:\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• cleanroom qualification tested on analog types; please note \"cleanroom qualification\" in your order\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 12 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e 2 x 4\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 9.8\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e120.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e184.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62681116115313,"sku":"NNC11766","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/2_e86efd53-52b0-46b5-a457-990ba002c00c.png?v=1763705792"},{"product_id":"12-awg-3c-helukabel-11768-jz-500-hmh-c-highly-flame-retardant-control-and-connection-cable","title":"12 AWG 3C Helukabel 11768 JZ-500 HMH-C Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11656_EN_GB_1.pdf?v=1763615242\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 3C Helukabel 11768 JZ-500 HMH-C Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster. The high degree of screening assures an interference-free transmission of signals and pulses. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and allround large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e12 AWG 3C HMH-C control and connection cable. Flame retardant HMH cable for control systems, Flexible control cables HMH-C, HELUKABEL flame retardant control wiring, Flame retardant connection wire, Flame resistant 12 AWG 3C HMH-C cable, JZ-500 HMH-C wire for control, JZ-500 HMH-C connection cable, 12 AWG 3C Highly flame retardant control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e2000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363- 7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil\u003cbr\u003e• halogen-free\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332- 3-24 \/ IEC 60332-3-24\u003cbr\u003e• smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034- 1+2 \/ IEC 61034-1+2\u003cbr\u003e• certifications and approvals:\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• cleanroom qualification tested on analog types; please note \"cleanroom qualification\" in your order\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size :\u003c\/strong\u003e\u003cspan\u003e 12 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm² :\u003c\/strong\u003e 3 G 4\u003cstrong\u003e\u003cbr\u003e• Outer Ø app. mm:\u003c\/strong\u003e\u003cspan\u003e 10.4\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e174.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e238.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62681117983089,"sku":"NNC11768","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/4-Photoroom_1_db96c68c-f47a-4873-ba59-de28994d2c26.png?v=1763629849"}],"url":"https:\/\/nassaunationalcable.com\/en-ca\/collections\/helukabel-jz-500-hmh-c-oz-500-hmh-c-highly-flame-retardant-control-and-connection-cable.oembed?page=5","provider":"NassauNationalCable","version":"1.0","type":"link"}