12 AWG 4C Helukabel 11122 JB-750 PVC Control and Connection Cable

Where are we? 4 Continents 9 Countries


Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Quick Support
12 AWG 4C Helukabel 11122 JB-750 PVC Control and Connection Cable
Applications:
Used for flexible applications involving medium mechanical stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use as a connection and control cable in machine tools, assembly lines, conveyor belts, production lines, plant construction, heating and air conditioning technology, power plants, smelters and steel mills.
Also Known As:
12 AWG 4C Helukabel JB-750 cable, JB-750 PVC control cable, Helukabel control cable, 12 AWG 4C Helukabel connection cable JB-750, Helukabel PVC, JB-750 Helukabel PVC, Helukabel flexible cable, JB-750 Helukabel flexible cable, Helukabel JB-750 wiring. PVC insulated cable, 12 AWG 4C JB-750 PVC insulated cable.
Technical Data:
PVC control and connection cable in alignment with DIN VDE 0285-525-2-11 / DIN EN 50525-2-11
Temperature range
flexible -15°C to +80°C
fixed -40°C to +80°C
Nominal voltage
AC U0/U 450/750 V
fixed and protected installation
AC U0/U 600/1000 V
Test voltage core/core
4000 V
Breakdown voltage
8000 V
Minimum bending radius
flexible7.5x Outer-Ø
fixed 4x Outer-Ø
Cable Structure:
• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 / IEC 60228 Class 5
• Core insulation: PVC acc. to DIN VDE 0207-363-3 / DIN EN 50363-3 (compound type TI2)
• Core identification acc. to JB/OB colour code, colour coded
• Protective conductor: starting with 3 cores,
G = with protective conductor GN-YE, in the outer layer,
X = without protective conductor (OB)
• Cores stranded in layers with optimal lay lengths
• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 / DIN EN 50363-4-1 (compound type TM2)
• Sheath colour: grey (RAL 7001)
• Length marking: in meters
Properties:
• largely resistant to: oil, for details, see "Technical Information"
• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers
Tests:
• flame-retardant acc. to DIN VDE 0482-332-1-2 / DIN EN 60332- 1-2 / IEC 60332-1-2
• certifications and approvals: EAC
Notes:
• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only
• cleanroom qualification tested on analog types; please note "cleanroom qualification" in your order
Specification:
• Size : 12 AWG
• No. cores x cross-sec. mm²: 4 G 4
• Outer Ø mm, approx: 12.6
• Cu factor per km: 154.0
• Weight kg/km, approx: 295.0
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460