ECS FAG22-06CB0 22 AWG 6C Solid Bare Copper Unshielded PVC 300V 105°C CMG FT4 Fire Alarm Cable
![ECS FAG22-06CB0 22 AWG 6C Solid Bare Copper Unshielded PVC 300V 105°C CMG FT4 Fire Alarm Cable](http://nassaunationalcable.com/cdn/shop/products/1_9f71924b-f2d5-4d5e-8b5b-a353d4fe1a8d_{width}x.png?v=1670138191)
Where are we? 4 Continents 8 Countries
![map](http://nassaunationalcable.com/cdn/shop/t/125/assets/MapDesign1.png?v=141730508087340066881694327314)
![garrie](http://nassaunationalcable.com/cdn/shop/t/125/assets/garrie11.png?v=147058525823915106791694327288)
Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Chat
Live Chat: Bottom Right Corner!
Email Us
info@nassaunationalcable.com
Quick Support
Product Information
Specification
ECS FAG22-06CB0 22 AWG 6C Solid Bare Copper Unshielded PVC 300V 105°C CMG FT4 Fire Alarm Cable
Allowable Ampacity for ECS FAG22-06CB0 22 AWG 6C Solid Bare Copper Unshielded PVC 300V 105°C CMG FT4 Fire Alarm Cable: 100 Amps
• FAS 105: Fire Alarm & Signal Cable for interconnection of electrical devices within a security and fire protective signaling system. The cables are intended for installation according to Section 32 of the Canadian Electrical Code Part 1 2002 Edition.
• LVT: Class 2 circuit wiring for installation according to Section 16 of the CEC Part 1 2002 Edition.
• FT1: For installation in buildings of combustible construction (excluding plenum areas) per the CEC PT-1 1998 Edition Rule 2-126 and the National Building Code 1995 Edition Article 3.1.4.3.
• FT4: For installation in buildings of non-combustible construction and plenum areas in any building per the CEC Part 1 Rule 2-126 and the National Building Code 1995 Edition Articles 3.1.5.17 and 3.6.4.3.
Also Known as:
Component Cable, ECS Cable, Alarm Cable, ECS Fire Cable, Electrical Cable, FT4 Alarm Cable, Signal Cable
Description:
Solid bare copper conductors, PVC insulation, Red PVC jacket FT-4 -20° C to 105° C, 300 Volts, CSA Approved.
Specification:
AWG Size: 22
Number of Conductor: 6
Stranding: Solid
Conductor: Bare Copper
Insulation: PVC
Jacket: PVC
Shielding Type: Unshielded
Wall Thickness Insulation: 0.015 inches
Wall Thickness Jacket: 0.030 inches
Nominal O.D. (inches): 0.225
Voltage: 300 V
Weight: 113 (lbs/km)
Part Number: FAG22-06CB0