{"title":"Copper XLPE RW90 Machine Flex Power Wire","description":"\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003eCopper XLPE RW90 Machine Flex Power Wire\u003c\/span\u003e\u003c\/h2\u003e","products":[{"product_id":"copper-xlpe-rw90-machine-flex-power-wire","title":"Copper XLPE RW90 Machine Flex Power Wire","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC44069_1.pdf?v=1782458405\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003eCopper XLPE RW90 Machine Flex Power Wire\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eType XHHW-2 \u0026amp; RW90 conductors are primarily used in conduit, cable tray or other recognized raceways for service, feeders, and branch circuit wiring as specified in the National Electric Code (NEC) and the Canadian Electrical Code (CE Code). XHHW-2 \u0026amp; RW90 conductors may be used at conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. Voltage rating for XHHW-2 conductors is 600 volts and 1000 volts. Voltage rating for RW90 conductors is 600 volts. Flexible bare copper stranding allows for ease of installation in locations with limited space, as well as including for use in electrical equipment for industrial facilities with harsh chemical environments, telecommunications applications and data centers.Type XHHW-2 600 Volts or 1000 Volts and Type RW90 600V. Rated 90°C Dry\/Wet,-40°C. Flexible Bare Copper Conductors. Cross-Linked Polyethylene (XLPE) Insulation. Rated High-Heat, Flame, Moisture, Gasoline, Oil and Sunlight Resistant.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eCopper RW90 Machine Flex Cable \u003cspan class=\"PDq2pG_selectionAnchor\" aria-hidden=\"true\"\u003e\u003c\/span\u003eXLPE RW90 Flexible Copper Power WireRW90 XLPE Machine Power Cable Flexible Copper RW90 Power Cable XLPE Insulated RW90 Copper Wire Machine Flex XLPE Power Cable RW90 Industrial Flexible Power Wire Flexible XLPE Copper Building Wire Class K Flexible Copper RW90 Cable XHHW-2 \/ RW90 Machine Flex Power Wire \u003cem data-end=\"448\" data-start=\"428\"\u003e(where dual-rated)\u003c\/em\u003e  \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e600V RW90 XLPE Copper Power Wire Industrial XLPE Flexible Copper Cable Flexible Stranded Copper RW90 Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B172 Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test (1\/0 and Larger)\u003cbr\u003e• CSA C22.2 No. 38 Thermoset-insulated wires and cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• CE\/RoHS-2 – The CE Marking has been applied solely to express the conformance to the material restrictions identified in\u003cbr\u003ethe RoHS-2 (2011\/65\/EU) Directive\u003cbr\u003e• Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j)\u003cbr\u003eand the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661\u003cbr\u003e• Sunlight Resistance \u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e1. \u003cstrong\u003eConductors:\u003c\/strong\u003e  8 AWG - 4\/0 AWG: Class K, flexible stranded, soft-drawn bare copper. 250 kcmil - 750 kcmil; Class I, flexible concentric ropelay stranded, soft-drawn bare copper\u003cbr\u003e2. \u003cstrong\u003eInsulation: \u003c\/strong\u003e Black, sunlight, gas, \u0026amp; oil resistant Cross-Linked Polyethylene (XLPE) \u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":64113139188081,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_1_0d8c21a5-aa83-4825-9c5f-0b35e31b90fa.png?v=1782458455"},{"product_id":"8-awg-168-strand-bare-copper-xlpe-rw90-machine-flex-power-wire","title":"8 AWG 168 Strand Bare Copper XLPE RW90 Machine Flex Power Wire","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC44069_1.pdf?v=1782458405\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e8 AWG 168 Strand Bare Copper XLPE RW90 Machine Flex Power Wire\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eType XHHW-2 \u0026amp; RW90 conductors are primarily used in conduit, cable tray or other recognized raceways for service, feeders, and branch circuit wiring as specified in the National Electric Code (NEC) and the Canadian Electrical Code (CE Code). XHHW-2 \u0026amp; RW90 conductors may be used at conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. Voltage rating for XHHW-2 conductors is 600 volts and 1000 volts. Voltage rating for RW90 conductors is 600 volts. Flexible bare copper stranding allows for ease of installation in locations with limited space, as well as including for use in electrical equipment for industrial facilities with harsh chemical environments, telecommunications applications and data centers.Type XHHW-2 600 Volts or 1000 Volts and Type RW90 600V. Rated 90°C Dry\/Wet,-40°C. Flexible Bare Copper Conductors. Cross-Linked Polyethylene (XLPE) Insulation. Rated High-Heat, Flame, Moisture, Gasoline, Oil and Sunlight Resistant.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e8 AWG Copper RW90 Machine Flex Cable \u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003eXLPE RW90 Flexible Copper Power WireRW90 XLPE Machine Power Cable Flexible 8 AWG Copper RW90 Power Cable XLPE Insulated RW90 Copper Wire Machine Flex XLPE Power Cable RW90 Industrial Flexible Power Wire Flexible XLPE 8 AWG Copper Building Wire Class K Flexible Copper RW90 Cable XHHW-2 \/ RW90 Machine Flex Power Wire \u003cem data-start=\"428\" data-end=\"448\"\u003e(where dual-rated)\u003c\/em\u003e  \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e600V RW90 XLPE Copper Power Wire Industrial XLPE Flexible Copper Cable Flexible Stranded Copper RW90 Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B172 Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test (1\/0 and Larger)\u003cbr\u003e• CSA C22.2 No. 38 Thermoset-insulated wires and cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• CE\/RoHS-2 – The CE Marking has been applied solely to express the conformance to the material restrictions identified in\u003cbr\u003ethe RoHS-2 (2011\/65\/EU) Directive\u003cbr\u003e• Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j)\u003cbr\u003eand the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661\u003cbr\u003e• Sunlight Resistance \u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e1. \u003cstrong\u003eConductors:\u003c\/strong\u003e  8 AWG - 4\/0 AWG: Class K, flexible stranded, soft-drawn bare copper. 250 kcmil - 750 kcmil; Class I, flexible concentric ropelay stranded, soft-drawn bare copper\u003cbr\u003e2. \u003cstrong\u003eInsulation: \u003c\/strong\u003e Black, sunlight, gas, \u0026amp; oil resistant Cross-Linked Polyethylene (XLPE) \u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e  8 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Cond. Number: \u003c\/strong\u003e1\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003e• Number of Strands: \u003c\/strong\u003e 168\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor  inch :\u003c\/strong\u003e 0.153\u003cbr\u003e\u003cstrong\u003e•  Insul Thickness (mil):\u003c\/strong\u003e  45\u003cbr\u003e\u003cstrong\u003e• Approx. OD (inch) :\u003c\/strong\u003e 0.243\u003cbr\u003e\u003cstrong\u003e• Approx. Weight lb\/1000ft :  \u003c\/strong\u003e66\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C: \u003c\/strong\u003e0.715\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C :\u003c\/strong\u003e  0.861\u003cbr\u003e\u003cstrong\u003e• Inductive Reactance@ Ω\/1000ft : \u003c\/strong\u003e 0.052\u003cbr\u003e\u003cstrong\u003e• Max Pull Tension lb: \u003c\/strong\u003e132\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMin Bending Radius lb: \u003c\/strong\u003e0.9\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C Amp  : \u003c\/strong\u003e50\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C Amp :  \u003c\/strong\u003e55\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":64113164616049,"sku":"NNC985623","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_1_0d8c21a5-aa83-4825-9c5f-0b35e31b90fa.png?v=1782458455"},{"product_id":"6-awg-266-strand-bare-copper-xlpe-rw90-machine-flex-power-wire","title":"6 AWG 266 Strand Bare Copper XLPE RW90 Machine Flex Power Wire","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC44069_1.pdf?v=1782458405\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e6 AWG 266 Strand Bare Copper XLPE RW90 Machine Flex Power Wire\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eType XHHW-2 \u0026amp; RW90 conductors are primarily used in conduit, cable tray or other recognized raceways for service, feeders, and branch circuit wiring as specified in the National Electric Code (NEC) and the Canadian Electrical Code (CE Code). XHHW-2 \u0026amp; RW90 conductors may be used at conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. Voltage rating for XHHW-2 conductors is 600 volts and 1000 volts. Voltage rating for RW90 conductors is 600 volts. Flexible bare copper stranding allows for ease of installation in locations with limited space, as well as including for use in electrical equipment for industrial facilities with harsh chemical environments, telecommunications applications and data centers.Type XHHW-2 600 Volts or 1000 Volts and Type RW90 600V. Rated 90°C Dry\/Wet,-40°C. Flexible Bare Copper Conductors. Cross-Linked Polyethylene (XLPE) Insulation. Rated High-Heat, Flame, Moisture, Gasoline, Oil and Sunlight Resistant.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e6 AWG Copper RW90 Machine Flex Cable \u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003eXLPE RW90 Flexible Copper Power WireRW90 XLPE Machine Power Cable Flexible 6 AWG Copper RW90 Power Cable XLPE Insulated RW90 Copper Wire Machine Flex XLPE Power Cable RW90 Industrial Flexible Power Wire Flexible XLPE 6 AWG Copper Building Wire Class K Flexible Copper RW90 Cable XHHW-2 \/ RW90 Machine Flex Power Wire \u003cem data-start=\"428\" data-end=\"448\"\u003e(where dual-rated)\u003c\/em\u003e  \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e600V RW90 XLPE Copper Power Wire Industrial XLPE Flexible Copper Cable Flexible Stranded Copper RW90 Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B172 Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test (1\/0 and Larger)\u003cbr\u003e• CSA C22.2 No. 38 Thermoset-insulated wires and cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• CE\/RoHS-2 – The CE Marking has been applied solely to express the conformance to the material restrictions identified in\u003cbr\u003ethe RoHS-2 (2011\/65\/EU) Directive\u003cbr\u003e• Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j)\u003cbr\u003eand the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661\u003cbr\u003e• Sunlight Resistance \u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e1. \u003cstrong\u003eConductors:\u003c\/strong\u003e  8 AWG - 4\/0 AWG: Class K, flexible stranded, soft-drawn bare copper. 250 kcmil - 750 kcmil; Class I, flexible concentric ropelay stranded, soft-drawn bare copper\u003cbr\u003e2. \u003cstrong\u003eInsulation: \u003c\/strong\u003e Black, sunlight, gas, \u0026amp; oil resistant Cross-Linked Polyethylene (XLPE) \u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e  6 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Cond. Number: \u003c\/strong\u003e1\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003e• Number of Strands: \u003c\/strong\u003e  266\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor  inch :\u003c\/strong\u003e 0.198\u003cbr\u003e\u003cstrong\u003e•  Insul Thickness (mil):\u003c\/strong\u003e  45\u003cbr\u003e\u003cstrong\u003e• Approx. OD (inch) :\u003c\/strong\u003e 0.288\u003cbr\u003e\u003cstrong\u003e• Approx. Weight lb\/1000ft : \u003c\/strong\u003e 106\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C: \u003c\/strong\u003e0.450\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C :\u003c\/strong\u003e   0.541\u003cbr\u003e\u003cstrong\u003e• Inductive Reactance@ Ω\/1000ft : \u003c\/strong\u003e 0.051\u003cbr\u003e\u003cstrong\u003e• Max Pull Tension lb: \u003c\/strong\u003e209\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMin Bending Radius lb: \u003c\/strong\u003e1.1\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C Amp  : \u003c\/strong\u003e65\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C Amp :  \u003c\/strong\u003e75\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":64113187619185,"sku":"NNC659974","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_1_0d8c21a5-aa83-4825-9c5f-0b35e31b90fa.png?v=1782458455"},{"product_id":"4-awg-420-strand-bare-copper-xlpe-rw90-machine-flex-power-wire","title":"4 AWG 420 Strand Bare Copper XLPE RW90 Machine Flex Power Wire","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC44069_1.pdf?v=1782458405\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e4 AWG 420 Strand Bare Copper XLPE RW90 Machine Flex Power Wire\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eType XHHW-2 \u0026amp; RW90 conductors are primarily used in conduit, cable tray or other recognized raceways for service, feeders, and branch circuit wiring as specified in the National Electric Code (NEC) and the Canadian Electrical Code (CE Code). XHHW-2 \u0026amp; RW90 conductors may be used at conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. Voltage rating for XHHW-2 conductors is 600 volts and 1000 volts. Voltage rating for RW90 conductors is 600 volts. Flexible bare copper stranding allows for ease of installation in locations with limited space, as well as including for use in electrical equipment for industrial facilities with harsh chemical environments, telecommunications applications and data centers.Type XHHW-2 600 Volts or 1000 Volts and Type RW90 600V. Rated 90°C Dry\/Wet,-40°C. Flexible Bare Copper Conductors. Cross-Linked Polyethylene (XLPE) Insulation. Rated High-Heat, Flame, Moisture, Gasoline, Oil and Sunlight Resistant.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e4 AWG Copper RW90 Machine Flex Cable \u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003eXLPE RW90 Flexible Copper Power WireRW90 XLPE Machine Power Cable Flexible 4 AWG Copper RW90 Power Cable XLPE Insulated RW90 Copper Wire Machine Flex XLPE Power Cable RW90 Industrial Flexible Power Wire Flexible XLPE 4 AWG Copper Building Wire Class K Flexible Copper RW90 Cable XHHW-2 \/ RW90 Machine Flex Power Wire \u003cem data-start=\"428\" data-end=\"448\"\u003e(where dual-rated)\u003c\/em\u003e  \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e600V RW90 XLPE Copper Power Wire Industrial XLPE Flexible Copper Cable Flexible Stranded Copper RW90 Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B172 Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test (1\/0 and Larger)\u003cbr\u003e• CSA C22.2 No. 38 Thermoset-insulated wires and cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• CE\/RoHS-2 – The CE Marking has been applied solely to express the conformance to the material restrictions identified in\u003cbr\u003ethe RoHS-2 (2011\/65\/EU) Directive\u003cbr\u003e• Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j)\u003cbr\u003eand the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661\u003cbr\u003e• Sunlight Resistance \u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e1. \u003cstrong\u003eConductors:\u003c\/strong\u003e  8 AWG - 4\/0 AWG: Class K, flexible stranded, soft-drawn bare copper. 250 kcmil - 750 kcmil; Class I, flexible concentric ropelay stranded, soft-drawn bare copper\u003cbr\u003e2. \u003cstrong\u003eInsulation: \u003c\/strong\u003e Black, sunlight, gas, \u0026amp; oil resistant Cross-Linked Polyethylene (XLPE) \u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e  4 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Cond. Number: \u003c\/strong\u003e1\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003e• Number of Strands:  \u003c\/strong\u003e420\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor  inch :\u003c\/strong\u003e 0.235\u003cbr\u003e\u003cstrong\u003e•  Insul Thickness (mil):\u003c\/strong\u003e  45\u003cbr\u003e\u003cstrong\u003e• Approx. OD (inch) :\u003c\/strong\u003e 0.325\u003cbr\u003e\u003cstrong\u003e• Approx. Weight lb\/1000ft :  \u003c\/strong\u003e150\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C: \u003c\/strong\u003e0.282\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C :\u003c\/strong\u003e  0.340\u003cbr\u003e\u003cstrong\u003e• Inductive Reactance@ Ω\/1000ft : \u003c\/strong\u003e 0.048\u003cbr\u003e\u003cstrong\u003e• Max Pull Tension lb: \u003c\/strong\u003e333\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMin Bending Radius lb: \u003c\/strong\u003e1.3\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C Amp : \u003c\/strong\u003e85\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C Amp :  \u003c\/strong\u003e95\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":64113194008945,"sku":"NNC856932","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_1_0d8c21a5-aa83-4825-9c5f-0b35e31b90fa.png?v=1782458455"},{"product_id":"2-awg-665-strand-bare-copper-xlpe-rw90-machine-flex-power-wire","title":"2 AWG  665 Strand Bare Copper XLPE RW90 Machine Flex Power Wire","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC44069_1.pdf?v=1782458405\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e2 AWG 665 Strand Bare Copper XLPE RW90 Machine Flex Power Wire\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eType XHHW-2 \u0026amp; RW90 conductors are primarily used in conduit, cable tray or other recognized raceways for service, feeders, and branch circuit wiring as specified in the National Electric Code (NEC) and the Canadian Electrical Code (CE Code). XHHW-2 \u0026amp; RW90 conductors may be used at conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. Voltage rating for XHHW-2 conductors is 600 volts and 1000 volts. Voltage rating for RW90 conductors is 600 volts. Flexible bare copper stranding allows for ease of installation in locations with limited space, as well as including for use in electrical equipment for industrial facilities with harsh chemical environments, telecommunications applications and data centers.Type XHHW-2 600 Volts or 1000 Volts and Type RW90 600V. Rated 90°C Dry\/Wet,-40°C. Flexible Bare Copper Conductors. Cross-Linked Polyethylene (XLPE) Insulation. Rated High-Heat, Flame, Moisture, Gasoline, Oil and Sunlight Resistant.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e2 AWG Copper RW90 Machine Flex Cable \u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003eXLPE RW90 Flexible Copper Power WireRW90 XLPE Machine Power Cable Flexible 2 AWG Copper RW90 Power Cable XLPE Insulated RW90 Copper Wire Machine Flex XLPE Power Cable RW90 Industrial Flexible Power Wire Flexible XLPE 2 AWG Copper Building Wire Class K Flexible Copper RW90 Cable XHHW-2 \/ RW90 Machine Flex Power Wire \u003cem data-start=\"428\" data-end=\"448\"\u003e(where dual-rated)\u003c\/em\u003e  \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e600V RW90 XLPE Copper Power Wire Industrial XLPE Flexible Copper Cable Flexible Stranded Copper RW90 Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B172 Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test (1\/0 and Larger)\u003cbr\u003e• CSA C22.2 No. 38 Thermoset-insulated wires and cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• CE\/RoHS-2 – The CE Marking has been applied solely to express the conformance to the material restrictions identified in\u003cbr\u003ethe RoHS-2 (2011\/65\/EU) Directive\u003cbr\u003e• Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j)\u003cbr\u003eand the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661\u003cbr\u003e• Sunlight Resistance \u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e1. \u003cstrong\u003eConductors:\u003c\/strong\u003e  8 AWG - 4\/0 AWG: Class K, flexible stranded, soft-drawn bare copper. 250 kcmil - 750 kcmil; Class I, flexible concentric ropelay stranded, soft-drawn bare copper\u003cbr\u003e2. \u003cstrong\u003eInsulation: \u003c\/strong\u003e Black, sunlight, gas, \u0026amp; oil resistant Cross-Linked Polyethylene (XLPE) \u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e  2 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Cond. Number: \u003c\/strong\u003e1\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003e• Number of Strands:  \u003c\/strong\u003e665\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor  inch :\u003c\/strong\u003e 0.302\u003cbr\u003e\u003cstrong\u003e•  Insul Thickness (mil):\u003c\/strong\u003e  45\u003cbr\u003e\u003cstrong\u003e• Approx. OD (inch) :\u003c\/strong\u003e 0.392\u003cbr\u003e\u003cstrong\u003e• Approx. Weight lb\/1000ft :  \u003c\/strong\u003e240\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C:  \u003c\/strong\u003e0.179\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C :\u003c\/strong\u003e  0.216\u003cbr\u003e\u003cstrong\u003e• Inductive Reactance@ Ω\/1000ft : \u003c\/strong\u003e 0.045\u003cbr\u003e\u003cstrong\u003e• Max Pull Tension lb:  \u003c\/strong\u003e530\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMin Bending Radius lb: \u003c\/strong\u003e1.5\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C Amp : \u003c\/strong\u003e115\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C Amp :  \u003c\/strong\u003e130\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":64113196695921,"sku":"NNC785965","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_1_0d8c21a5-aa83-4825-9c5f-0b35e31b90fa.png?v=1782458455"},{"product_id":"1-awg-836-strand-bare-copper-xlpe-rw90-machine-flex-power-wire","title":"1 AWG  836 Strand Bare Copper XLPE RW90 Machine Flex Power Wire","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC44069_1.pdf?v=1782458405\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e1 AWG 836 Strand Bare Copper XLPE RW90 Machine Flex Power Wire\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eType XHHW-2 \u0026amp; RW90 conductors are primarily used in conduit, cable tray or other recognized raceways for service, feeders, and branch circuit wiring as specified in the National Electric Code (NEC) and the Canadian Electrical Code (CE Code). XHHW-2 \u0026amp; RW90 conductors may be used at conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. Voltage rating for XHHW-2 conductors is 600 volts and 1000 volts. Voltage rating for RW90 conductors is 600 volts. Flexible bare copper stranding allows for ease of installation in locations with limited space, as well as including for use in electrical equipment for industrial facilities with harsh chemical environments, telecommunications applications and data centers.Type XHHW-2 600 Volts or 1000 Volts and Type RW90 600V. Rated 90°C Dry\/Wet,-40°C. Flexible Bare Copper Conductors. Cross-Linked Polyethylene (XLPE) Insulation. Rated High-Heat, Flame, Moisture, Gasoline, Oil and Sunlight Resistant.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e1 AWG Copper RW90 Machine Flex Cable \u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003eXLPE RW90 Flexible Copper Power WireRW90 XLPE Machine Power Cable Flexible 1 AWG Copper RW90 Power Cable XLPE Insulated RW90 Copper Wire Machine Flex XLPE Power Cable RW90 Industrial Flexible Power Wire Flexible XLPE 1 AWG Copper Building Wire Class K Flexible Copper RW90 Cable XHHW-2 \/ RW90 Machine Flex Power Wire \u003cem data-start=\"428\" data-end=\"448\"\u003e(where dual-rated)\u003c\/em\u003e  \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e600V RW90 XLPE Copper Power Wire Industrial XLPE Flexible Copper Cable Flexible Stranded Copper RW90 Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B172 Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test (1\/0 and Larger)\u003cbr\u003e• CSA C22.2 No. 38 Thermoset-insulated wires and cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• CE\/RoHS-2 – The CE Marking has been applied solely to express the conformance to the material restrictions identified in\u003cbr\u003ethe RoHS-2 (2011\/65\/EU) Directive\u003cbr\u003e• Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j)\u003cbr\u003eand the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661\u003cbr\u003e• Sunlight Resistance \u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e1. \u003cstrong\u003eConductors:\u003c\/strong\u003e  8 AWG - 4\/0 AWG: Class K, flexible stranded, soft-drawn bare copper. 250 kcmil - 750 kcmil; Class I, flexible concentric ropelay stranded, soft-drawn bare copper\u003cbr\u003e2. \u003cstrong\u003eInsulation: \u003c\/strong\u003e Black, sunlight, gas, \u0026amp; oil resistant Cross-Linked Polyethylene (XLPE) \u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e  1 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Cond. Number: \u003c\/strong\u003e1\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003e• Number of Strands:  \u003c\/strong\u003e836\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor  inch :\u003c\/strong\u003e 0.397\u003cbr\u003e\u003cstrong\u003e•  Insul Thickness (mil):\u003c\/strong\u003e  55\u003cbr\u003e\u003cstrong\u003e• Approx. OD (inch) :\u003c\/strong\u003e 0.507\u003cbr\u003e\u003cstrong\u003e• Approx. Weight lb\/1000ft : \u003c\/strong\u003e306\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C:  \u003c\/strong\u003e 0.143\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C :\u003c\/strong\u003e 0.172\u003cbr\u003e\u003cstrong\u003e• Inductive Reactance@ Ω\/1000ft : \u003c\/strong\u003e 0.046\u003cbr\u003e\u003cstrong\u003e• Max Pull Tension lb: \u003c\/strong\u003e669\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMin Bending Radius lb: \u003c\/strong\u003e2.0\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C Amp :  \u003c\/strong\u003e130\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C Amp :  \u003c\/strong\u003e145\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":64113199808881,"sku":"NNC896542","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_1_0d8c21a5-aa83-4825-9c5f-0b35e31b90fa.png?v=1782458455"},{"product_id":"1-0-awg-1064-strand-bare-copper-xlpe-rw90-machine-flex-power-wire","title":"1\/0 AWG 1064 Strand Bare Copper XLPE RW90 Machine Flex Power Wire","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC44069_1.pdf?v=1782458405\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e1\/0 AWG 1064 Strand Bare Copper XLPE RW90 Machine Flex Power Wire\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eType XHHW-2 \u0026amp; RW90 conductors are primarily used in conduit, cable tray or other recognized raceways for service, feeders, and branch circuit wiring as specified in the National Electric Code (NEC) and the Canadian Electrical Code (CE Code). XHHW-2 \u0026amp; RW90 conductors may be used at conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. Voltage rating for XHHW-2 conductors is 600 volts and 1000 volts. Voltage rating for RW90 conductors is 600 volts. Flexible bare copper stranding allows for ease of installation in locations with limited space, as well as including for use in electrical equipment for industrial facilities with harsh chemical environments, telecommunications applications and data centers.Type XHHW-2 600 Volts or 1000 Volts and Type RW90 600V. Rated 90°C Dry\/Wet,-40°C. Flexible Bare Copper Conductors. Cross-Linked Polyethylene (XLPE) Insulation. Rated High-Heat, Flame, Moisture, Gasoline, Oil and Sunlight Resistant.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e1\/0 AWG Copper RW90 Machine Flex Cable \u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003eXLPE RW90 Flexible Copper Power WireRW90 XLPE Machine Power Cable Flexible 1\/0 AWG Copper RW90 Power Cable XLPE Insulated RW90 Copper Wire Machine Flex XLPE Power Cable RW90 Industrial Flexible Power Wire Flexible XLPE 1\/0 AWG Copper Building Wire Class K Flexible Copper RW90 Cable XHHW-2 \/ RW90 Machine Flex Power Wire \u003cem data-start=\"428\" data-end=\"448\"\u003e(where dual-rated)\u003c\/em\u003e  \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e600V RW90 XLPE Copper Power Wire Industrial XLPE Flexible Copper Cable Flexible Stranded Copper RW90 Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B172 Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test (1\/0 and Larger)\u003cbr\u003e• CSA C22.2 No. 38 Thermoset-insulated wires and cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• CE\/RoHS-2 – The CE Marking has been applied solely to express the conformance to the material restrictions identified in\u003cbr\u003ethe RoHS-2 (2011\/65\/EU) Directive\u003cbr\u003e• Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j)\u003cbr\u003eand the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661\u003cbr\u003e• Sunlight Resistance \u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e1. \u003cstrong\u003eConductors:\u003c\/strong\u003e  8 AWG - 4\/0 AWG: Class K, flexible stranded, soft-drawn bare copper. 250 kcmil - 750 kcmil; Class I, flexible concentric ropelay stranded, soft-drawn bare copper\u003cbr\u003e2. \u003cstrong\u003eInsulation: \u003c\/strong\u003e Black, sunlight, gas, \u0026amp; oil resistant Cross-Linked Polyethylene (XLPE) \u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e  1\/0 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Cond. Number: \u003c\/strong\u003e1\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003e• Number of Strands:  \u003c\/strong\u003e1064\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor  inch :\u003c\/strong\u003e 0.400\u003cbr\u003e\u003cstrong\u003e•  Insul Thickness (mil):\u003c\/strong\u003e  55\u003cbr\u003e\u003cstrong\u003e• Approx. OD (inch) :\u003c\/strong\u003e  0.510\u003cbr\u003e\u003cstrong\u003e• Approx. Weight lb\/1000ft : \u003c\/strong\u003e 374\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C:  \u003c\/strong\u003e0.113\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C :\u003c\/strong\u003e 0.136\u003cbr\u003e\u003cstrong\u003e• Inductive Reactance@ Ω\/1000ft : \u003c\/strong\u003e 0.044\u003cbr\u003e\u003cstrong\u003e• Max Pull Tension lb: \u003c\/strong\u003e 844\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMin Bending Radius lb: \u003c\/strong\u003e2.0\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C Amp :  \u003c\/strong\u003e 150\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C Amp :  \u003c\/strong\u003e170\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":64113203413361,"sku":"NNC669985","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_1_0d8c21a5-aa83-4825-9c5f-0b35e31b90fa.png?v=1782458455"},{"product_id":"2-0-awg-1330-strand-bare-copper-xlpe-rw90-machine-flex-power-wire","title":"2\/0 AWG 1330 Strand Bare Copper XLPE RW90 Machine Flex Power Wire","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC44069_1.pdf?v=1782458405\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e2\/0 AWG 1330 Strand Bare Copper XLPE RW90 Machine Flex Power Wire\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eType XHHW-2 \u0026amp; RW90 conductors are primarily used in conduit, cable tray or other recognized raceways for service, feeders, and branch circuit wiring as specified in the National Electric Code (NEC) and the Canadian Electrical Code (CE Code). XHHW-2 \u0026amp; RW90 conductors may be used at conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. Voltage rating for XHHW-2 conductors is 600 volts and 1000 volts. Voltage rating for RW90 conductors is 600 volts. Flexible bare copper stranding allows for ease of installation in locations with limited space, as well as including for use in electrical equipment for industrial facilities with harsh chemical environments, telecommunications applications and data centers.Type XHHW-2 600 Volts or 1000 Volts and Type RW90 600V. Rated 90°C Dry\/Wet,-40°C. Flexible Bare Copper Conductors. Cross-Linked Polyethylene (XLPE) Insulation. Rated High-Heat, Flame, Moisture, Gasoline, Oil and Sunlight Resistant.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e2\/0 AWG Copper RW90 Machine Flex Cable \u003cspan class=\"PDq2pG_selectionAnchor\" aria-hidden=\"true\"\u003e\u003c\/span\u003eXLPE RW90 Flexible Copper Power WireRW90 XLPE Machine Power Cable Flexible 2\/0 AWG Copper RW90 Power Cable XLPE Insulated RW90 Copper Wire Machine Flex XLPE Power Cable RW90 Industrial Flexible Power Wire Flexible XLPE 2\/0 AWG Copper Building Wire Class K Flexible Copper RW90 Cable XHHW-2 \/ RW90 Machine Flex Power Wire \u003cem data-end=\"448\" data-start=\"428\"\u003e(where dual-rated)\u003c\/em\u003e  \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e600V RW90 XLPE Copper Power Wire Industrial XLPE Flexible Copper Cable Flexible Stranded Copper RW90 Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B172 Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test (1\/0 and Larger)\u003cbr\u003e• CSA C22.2 No. 38 Thermoset-insulated wires and cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• CE\/RoHS-2 – The CE Marking has been applied solely to express the conformance to the material restrictions identified in\u003cbr\u003ethe RoHS-2 (2011\/65\/EU) Directive\u003cbr\u003e• Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j)\u003cbr\u003eand the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661\u003cbr\u003e• Sunlight Resistance \u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e1. \u003cstrong\u003eConductors:\u003c\/strong\u003e  8 AWG - 4\/0 AWG: Class K, flexible stranded, soft-drawn bare copper. 250 kcmil - 750 kcmil; Class I, flexible concentric ropelay stranded, soft-drawn bare copper\u003cbr\u003e2. \u003cstrong\u003eInsulation: \u003c\/strong\u003e Black, sunlight, gas, \u0026amp; oil resistant Cross-Linked Polyethylene (XLPE) \u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e  2\/0 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Cond. Number: \u003c\/strong\u003e1\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003e• Number of Strands: \u003c\/strong\u003e 1330\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor  inch :\u003c\/strong\u003e 0.420\u003cbr\u003e\u003cstrong\u003e•  Insul Thickness (mil):\u003c\/strong\u003e  60\u003cbr\u003e\u003cstrong\u003e• Approx. OD (inch) :\u003c\/strong\u003e   0.542\u003cbr\u003e\u003cstrong\u003e• Approx. Weight lb\/1000ft : \u003c\/strong\u003e 542\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C:  \u003c\/strong\u003e0.090\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C :\u003c\/strong\u003e 0.108\u003cbr\u003e\u003cstrong\u003e• Inductive Reactance@ Ω\/1000ft : \u003c\/strong\u003e0.043\u003cbr\u003e\u003cstrong\u003e• Max Pull Tension lb: \u003c\/strong\u003e 1064\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMin Bending Radius lb: \u003c\/strong\u003e2.2\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C Amp :  \u003c\/strong\u003e 175\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C Amp : \u003c\/strong\u003e195\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 325.114px; height: 35.5966px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e459838!\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":64113207345521,"sku":"NNC459838!","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_1_0d8c21a5-aa83-4825-9c5f-0b35e31b90fa.png?v=1782458455"},{"product_id":"4-0-awg-2109-strand-bare-copper-xlpe-rw90-machine-flex-power-wire","title":"4\/0 AWG 2109 Strand Bare Copper XLPE RW90 Machine Flex Power Wire","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC44069_1.pdf?v=1782458405\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e4\/0 AWG 2109 Strand Bare Copper XLPE RW90 Machine Flex Power Wire\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eType XHHW-2 \u0026amp; RW90 conductors are primarily used in conduit, cable tray or other recognized raceways for service, feeders, and branch circuit wiring as specified in the National Electric Code (NEC) and the Canadian Electrical Code (CE Code). XHHW-2 \u0026amp; RW90 conductors may be used at conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. Voltage rating for XHHW-2 conductors is 600 volts and 1000 volts. Voltage rating for RW90 conductors is 600 volts. Flexible bare copper stranding allows for ease of installation in locations with limited space, as well as including for use in electrical equipment for industrial facilities with harsh chemical environments, telecommunications applications and data centers.Type XHHW-2 600 Volts or 1000 Volts and Type RW90 600V. Rated 90°C Dry\/Wet,-40°C. Flexible Bare Copper Conductors. Cross-Linked Polyethylene (XLPE) Insulation. Rated High-Heat, Flame, Moisture, Gasoline, Oil and Sunlight Resistant.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e4\/0 AWG Copper RW90 Machine Flex Cable \u003cspan class=\"PDq2pG_selectionAnchor\" aria-hidden=\"true\"\u003e\u003c\/span\u003eXLPE RW90 Flexible Copper Power WireRW90 XLPE Machine Power Cable Flexible 4\/0 AWG Copper RW90 Power Cable XLPE Insulated RW90 Copper Wire Machine Flex XLPE Power Cable RW90 Industrial Flexible Power Wire Flexible XLPE 4\/0 AWG Copper Building Wire Class K Flexible Copper RW90 Cable XHHW-2 \/ RW90 Machine Flex Power Wire \u003cem data-end=\"448\" data-start=\"428\"\u003e(where dual-rated)\u003c\/em\u003e  \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e600V RW90 XLPE Copper Power Wire Industrial XLPE Flexible Copper Cable Flexible Stranded Copper RW90 Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B172 Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test (1\/0 and Larger)\u003cbr\u003e• CSA C22.2 No. 38 Thermoset-insulated wires and cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• CE\/RoHS-2 – The CE Marking has been applied solely to express the conformance to the material restrictions identified in\u003cbr\u003ethe RoHS-2 (2011\/65\/EU) Directive\u003cbr\u003e• Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j)\u003cbr\u003eand the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661\u003cbr\u003e• Sunlight Resistance \u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e1. \u003cstrong\u003eConductors:\u003c\/strong\u003e  8 AWG - 4\/0 AWG: Class K, flexible stranded, soft-drawn bare copper. 250 kcmil - 750 kcmil; Class I, flexible concentric ropelay stranded, soft-drawn bare copper\u003cbr\u003e2. \u003cstrong\u003eInsulation: \u003c\/strong\u003e Black, sunlight, gas, \u0026amp; oil resistant Cross-Linked Polyethylene (XLPE) \u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e  4\/0 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Cond. Number: \u003c\/strong\u003e1\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003e• Number of Strands: \u003c\/strong\u003e 2109\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor  inch :\u003c\/strong\u003e  0.520\u003cbr\u003e\u003cstrong\u003e•  Insul Thickness (mil):\u003c\/strong\u003e  55\u003cbr\u003e\u003cstrong\u003e• Approx. OD (inch) :\u003c\/strong\u003e   0.642\u003cbr\u003e\u003cstrong\u003e• Approx. Weight lb\/1000ft : \u003c\/strong\u003e 730\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C:  \u003c\/strong\u003e0.057\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C :\u003c\/strong\u003e 0.069\u003cbr\u003e\u003cstrong\u003e• Inductive Reactance@ Ω\/1000ft : \u003c\/strong\u003e0.041\u003cbr\u003e\u003cstrong\u003e• Max Pull Tension lb: \u003c\/strong\u003e  1692\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMin Bending Radius lb: \u003c\/strong\u003e2.6\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C Amp :  \u003c\/strong\u003e 230\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C Amp : \u003c\/strong\u003e260\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 325.114px; height: 35.5966px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e457084\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":64113209573745,"sku":"NNC457084","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_1_0d8c21a5-aa83-4825-9c5f-0b35e31b90fa.png?v=1782458455"},{"product_id":"3-0-awg-1666-strand-bare-copper-xlpe-rw90-machine-flex-power-wire","title":"3\/0 AWG 1666 Strand Bare Copper XLPE RW90 Machine Flex Power Wire","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC44069_1.pdf?v=1782458405\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e3\/0 AWG 1666 Strand Bare Copper XLPE RW90 Machine Flex Power Wire\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eType XHHW-2 \u0026amp; RW90 conductors are primarily used in conduit, cable tray or other recognized raceways for service, feeders, and branch circuit wiring as specified in the National Electric Code (NEC) and the Canadian Electrical Code (CE Code). XHHW-2 \u0026amp; RW90 conductors may be used at conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. Voltage rating for XHHW-2 conductors is 600 volts and 1000 volts. Voltage rating for RW90 conductors is 600 volts. Flexible bare copper stranding allows for ease of installation in locations with limited space, as well as including for use in electrical equipment for industrial facilities with harsh chemical environments, telecommunications applications and data centers.Type XHHW-2 600 Volts or 1000 Volts and Type RW90 600V. Rated 90°C Dry\/Wet,-40°C. Flexible Bare Copper Conductors. Cross-Linked Polyethylene (XLPE) Insulation. Rated High-Heat, Flame, Moisture, Gasoline, Oil and Sunlight Resistant.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e3\/0 AWG Copper RW90 Machine Flex Cable \u003cspan class=\"PDq2pG_selectionAnchor\" aria-hidden=\"true\"\u003e\u003c\/span\u003eXLPE RW90 Flexible Copper Power WireRW90 XLPE Machine Power Cable Flexible 3\/0 AWG Copper RW90 Power Cable XLPE Insulated RW90 Copper Wire Machine Flex XLPE Power Cable RW90 Industrial Flexible Power Wire Flexible XLPE 3\/0 AWG Copper Building Wire Class K Flexible Copper RW90 Cable XHHW-2 \/ RW90 Machine Flex Power Wire \u003cem data-end=\"448\" data-start=\"428\"\u003e(where dual-rated)\u003c\/em\u003e  \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e600V RW90 XLPE Copper Power Wire Industrial XLPE Flexible Copper Cable Flexible Stranded Copper RW90 Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B172 Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test (1\/0 and Larger)\u003cbr\u003e• CSA C22.2 No. 38 Thermoset-insulated wires and cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• CE\/RoHS-2 – The CE Marking has been applied solely to express the conformance to the material restrictions identified in\u003cbr\u003ethe RoHS-2 (2011\/65\/EU) Directive\u003cbr\u003e• Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j)\u003cbr\u003eand the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661\u003cbr\u003e• Sunlight Resistance \u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e1. \u003cstrong\u003eConductors:\u003c\/strong\u003e  8 AWG - 4\/0 AWG: Class K, flexible stranded, soft-drawn bare copper. 250 kcmil - 750 kcmil; Class I, flexible concentric ropelay stranded, soft-drawn bare copper\u003cbr\u003e2. \u003cstrong\u003eInsulation: \u003c\/strong\u003e Black, sunlight, gas, \u0026amp; oil resistant Cross-Linked Polyethylene (XLPE) \u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e  3\/0 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Cond. Number: \u003c\/strong\u003e1\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003e• Number of Strands: \u003c\/strong\u003e 1666\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor  inch :\u003c\/strong\u003e   0.533\u003cbr\u003e\u003cstrong\u003e•  Insul Thickness (mil):\u003c\/strong\u003e  55\u003cbr\u003e\u003cstrong\u003e• Approx. OD (inch) :\u003c\/strong\u003e  0.603\u003cbr\u003e\u003cstrong\u003e• Approx. Weight lb\/1000ft : \u003c\/strong\u003e 578\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C:  \u003c\/strong\u003e0.072\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C :\u003c\/strong\u003e 0.087\u003cbr\u003e\u003cstrong\u003e• Inductive Reactance@ Ω\/1000ft :\u003c\/strong\u003e 0.042\u003cbr\u003e\u003cstrong\u003e• Max Pull Tension lb: \u003c\/strong\u003e 1342\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMin Bending Radius lb: \u003c\/strong\u003e2.5\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C Amp :  \u003c\/strong\u003e200\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C Amp : \u003c\/strong\u003e225\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 325.114px; height: 35.5966px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e457126\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":64113238507889,"sku":"NNC457126","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_1_0d8c21a5-aa83-4825-9c5f-0b35e31b90fa.png?v=1782458455"},{"product_id":"250-awg-627-strand-bare-copper-xlpe-rw90-machine-flex-power-wire","title":"250 AWG 627 Strand Bare Copper XLPE RW90 Machine Flex Power Wire","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC44069_1.pdf?v=1782458405\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e250 AWG 627 Strand Bare Copper XLPE RW90 Machine Flex Power Wire\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eType XHHW-2 \u0026amp; RW90 conductors are primarily used in conduit, cable tray or other recognized raceways for service, feeders, and branch circuit wiring as specified in the National Electric Code (NEC) and the Canadian Electrical Code (CE Code). XHHW-2 \u0026amp; RW90 conductors may be used at conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. Voltage rating for XHHW-2 conductors is 600 volts and 1000 volts. Voltage rating for RW90 conductors is 600 volts. Flexible bare copper stranding allows for ease of installation in locations with limited space, as well as including for use in electrical equipment for industrial facilities with harsh chemical environments, telecommunications applications and data centers.Type XHHW-2 600 Volts or 1000 Volts and Type RW90 600V. Rated 90°C Dry\/Wet,-40°C. Flexible Bare Copper Conductors. Cross-Linked Polyethylene (XLPE) Insulation. Rated High-Heat, Flame, Moisture, Gasoline, Oil and Sunlight Resistant.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e250 AWG Copper RW90 Machine Flex Cable \u003cspan class=\"PDq2pG_selectionAnchor\" aria-hidden=\"true\"\u003e\u003c\/span\u003eXLPE RW90 Flexible Copper Power WireRW90 XLPE Machine Power Cable Flexible 250 AWG Copper RW90 Power Cable XLPE Insulated RW90 Copper Wire Machine Flex XLPE Power Cable RW90 Industrial Flexible Power Wire Flexible XLPE 250 AWG Copper Building Wire Class K Flexible Copper RW90 Cable XHHW-2 \/ RW90 Machine Flex Power Wire \u003cem data-end=\"448\" data-start=\"428\"\u003e(where dual-rated)\u003c\/em\u003e  \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e600V RW90 XLPE Copper Power Wire Industrial XLPE Flexible Copper Cable Flexible Stranded Copper RW90 Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B172 Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test (1\/0 and Larger)\u003cbr\u003e• CSA C22.2 No. 38 Thermoset-insulated wires and cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• CE\/RoHS-2 – The CE Marking has been applied solely to express the conformance to the material restrictions identified in\u003cbr\u003ethe RoHS-2 (2011\/65\/EU) Directive\u003cbr\u003e• Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j)\u003cbr\u003eand the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661\u003cbr\u003e• Sunlight Resistance \u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e1. \u003cstrong\u003eConductors:\u003c\/strong\u003e  8 AWG - 4\/0 AWG: Class K, flexible stranded, soft-drawn bare copper. 250 kcmil - 750 kcmil; Class I, flexible concentric ropelay stranded, soft-drawn bare copper\u003cbr\u003e2. \u003cstrong\u003eInsulation: \u003c\/strong\u003e Black, sunlight, gas, \u0026amp; oil resistant Cross-Linked Polyethylene (XLPE) \u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e  250 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Cond. Number: \u003c\/strong\u003e1\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003e• Number of Strands: \u003c\/strong\u003e627\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor  inch :\u003c\/strong\u003e   0.605\u003cbr\u003e\u003cstrong\u003e•  Insul Thickness (mil):\u003c\/strong\u003e 65\u003cbr\u003e\u003cstrong\u003e• Approx. OD (inch) :\u003c\/strong\u003e  0.746\u003cbr\u003e\u003cstrong\u003e• Approx. Weight lb\/1000ft : \u003c\/strong\u003e850\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C:  \u003c\/strong\u003e 0.047\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C :\u003c\/strong\u003e 0.057\u003cbr\u003e\u003cstrong\u003e• Inductive Reactance@ Ω\/1000ft :\u003c\/strong\u003e 0.041\u003cbr\u003e\u003cstrong\u003e• Max Pull Tension lb: \u003c\/strong\u003e 2000\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMin Bending Radius lb: \u003c\/strong\u003e2.9\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C Amp : \u003c\/strong\u003e 255\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C Amp : \u003c\/strong\u003e290\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 325.114px; height: 35.5966px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e457085\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":64113248633201,"sku":"NNC457085","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_1_0d8c21a5-aa83-4825-9c5f-0b35e31b90fa.png?v=1782458455"},{"product_id":"300-awg-741-strand-bare-copper-xlpe-rw90-machine-flex-power-wire","title":"300 AWG 741 Strand Bare Copper XLPE RW90 Machine Flex Power Wire","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC44069_1.pdf?v=1782458405\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e300 AWG 741 Strand Bare Copper XLPE RW90 Machine Flex Power Wire\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eType XHHW-2 \u0026amp; RW90 conductors are primarily used in conduit, cable tray or other recognized raceways for service, feeders, and branch circuit wiring as specified in the National Electric Code (NEC) and the Canadian Electrical Code (CE Code). XHHW-2 \u0026amp; RW90 conductors may be used at conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. Voltage rating for XHHW-2 conductors is 600 volts and 1000 volts. Voltage rating for RW90 conductors is 600 volts. Flexible bare copper stranding allows for ease of installation in locations with limited space, as well as including for use in electrical equipment for industrial facilities with harsh chemical environments, telecommunications applications and data centers.Type XHHW-2 600 Volts or 1000 Volts and Type RW90 600V. Rated 90°C Dry\/Wet,-40°C. Flexible Bare Copper Conductors. Cross-Linked Polyethylene (XLPE) Insulation. Rated High-Heat, Flame, Moisture, Gasoline, Oil and Sunlight Resistant.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e300 AWG Copper RW90 Machine Flex Cable \u003cspan class=\"PDq2pG_selectionAnchor\" aria-hidden=\"true\"\u003e\u003c\/span\u003eXLPE RW90 Flexible Copper Power WireRW90 XLPE Machine Power Cable Flexible 300 AWG Copper RW90 Power Cable XLPE Insulated RW90 Copper Wire Machine Flex XLPE Power Cable RW90 Industrial Flexible Power Wire Flexible XLPE 300 AWG Copper Building Wire Class K Flexible Copper RW90 Cable XHHW-2 \/ RW90 Machine Flex Power Wire \u003cem data-end=\"448\" data-start=\"428\"\u003e(where dual-rated)\u003c\/em\u003e  \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e600V RW90 XLPE Copper Power Wire Industrial XLPE Flexible Copper Cable Flexible Stranded Copper RW90 Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B172 Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test (1\/0 and Larger)\u003cbr\u003e• CSA C22.2 No. 38 Thermoset-insulated wires and cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• CE\/RoHS-2 – The CE Marking has been applied solely to express the conformance to the material restrictions identified in\u003cbr\u003ethe RoHS-2 (2011\/65\/EU) Directive\u003cbr\u003e• Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j)\u003cbr\u003eand the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661\u003cbr\u003e• Sunlight Resistance \u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e1. \u003cstrong\u003eConductors:\u003c\/strong\u003e  8 AWG - 4\/0 AWG: Class K, flexible stranded, soft-drawn bare copper. 250 kcmil - 750 kcmil; Class I, flexible concentric ropelay stranded, soft-drawn bare copper\u003cbr\u003e2. \u003cstrong\u003eInsulation: \u003c\/strong\u003e Black, sunlight, gas, \u0026amp; oil resistant Cross-Linked Polyethylene (XLPE) \u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e  300 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Cond. Number: \u003c\/strong\u003e1\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003e• Number of Strands: \u003c\/strong\u003e741\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor  inch :\u003c\/strong\u003e   0.638\u003cbr\u003e\u003cstrong\u003e•  Insul Thickness (mil):\u003c\/strong\u003e 65\u003cbr\u003e\u003cstrong\u003e• Approx. OD (inch) :\u003c\/strong\u003e 0.778\u003cbr\u003e\u003cstrong\u003e• Approx. Weight lb\/1000ft :  \u003c\/strong\u003e1020\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C:\u003c\/strong\u003e 0.039\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C :\u003c\/strong\u003e 0.051\u003cbr\u003e\u003cstrong\u003e• Inductive Reactance@ Ω\/1000ft :\u003c\/strong\u003e 0.041\u003cbr\u003e\u003cstrong\u003e• Max Pull Tension lb: \u003c\/strong\u003e2400\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMin Bending Radius lb: \u003c\/strong\u003e3.1\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C Amp : \u003c\/strong\u003e 285\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C Amp : \u003c\/strong\u003e320\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 325.114px; height: 35.5966px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e457086\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":64113351590257,"sku":"NNC457086","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_1_0d8c21a5-aa83-4825-9c5f-0b35e31b90fa.png?v=1782458455"},{"product_id":"350-awg-893-strand-bare-copper-xlpe-rw90-machine-flex-power-wire","title":"350 AWG 893 Strand Bare Copper XLPE RW90 Machine Flex Power Wire","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC44069_1.pdf?v=1782458405\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e350 AWG 893 Strand Bare Copper XLPE RW90 Machine Flex Power Wire\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eType XHHW-2 \u0026amp; RW90 conductors are primarily used in conduit, cable tray or other recognized raceways for service, feeders, and branch circuit wiring as specified in the National Electric Code (NEC) and the Canadian Electrical Code (CE Code). XHHW-2 \u0026amp; RW90 conductors may be used at conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. Voltage rating for XHHW-2 conductors is 600 volts and 1000 volts. Voltage rating for RW90 conductors is 600 volts. Flexible bare copper stranding allows for ease of installation in locations with limited space, as well as including for use in electrical equipment for industrial facilities with harsh chemical environments, telecommunications applications and data centers.Type XHHW-2 600 Volts or 1000 Volts and Type RW90 600V. Rated 90°C Dry\/Wet,-40°C. Flexible Bare Copper Conductors. Cross-Linked Polyethylene (XLPE) Insulation. Rated High-Heat, Flame, Moisture, Gasoline, Oil and Sunlight Resistant.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e350 AWG Copper RW90 Machine Flex Cable \u003cspan class=\"PDq2pG_selectionAnchor\" aria-hidden=\"true\"\u003e\u003c\/span\u003eXLPE RW90 Flexible Copper Power WireRW90 XLPE Machine Power Cable Flexible 350 AWG Copper RW90 Power Cable XLPE Insulated RW90 Copper Wire Machine Flex XLPE Power Cable RW90 Industrial Flexible Power Wire Flexible XLPE 350 AWG Copper Building Wire Class K Flexible Copper RW90 Cable XHHW-2 \/ RW90 Machine Flex Power Wire \u003cem data-end=\"448\" data-start=\"428\"\u003e(where dual-rated)\u003c\/em\u003e  \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e600V RW90 XLPE Copper Power Wire Industrial XLPE Flexible Copper Cable Flexible Stranded Copper RW90 Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B172 Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test (1\/0 and Larger)\u003cbr\u003e• CSA C22.2 No. 38 Thermoset-insulated wires and cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• CE\/RoHS-2 – The CE Marking has been applied solely to express the conformance to the material restrictions identified in\u003cbr\u003ethe RoHS-2 (2011\/65\/EU) Directive\u003cbr\u003e• Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j)\u003cbr\u003eand the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661\u003cbr\u003e• Sunlight Resistance \u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e1. \u003cstrong\u003eConductors:\u003c\/strong\u003e  8 AWG - 4\/0 AWG: Class K, flexible stranded, soft-drawn bare copper. 250 kcmil - 750 kcmil; Class I, flexible concentric ropelay stranded, soft-drawn bare copper\u003cbr\u003e2. \u003cstrong\u003eInsulation: \u003c\/strong\u003e Black, sunlight, gas, \u0026amp; oil resistant Cross-Linked Polyethylene (XLPE) \u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e  350 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Cond. Number: \u003c\/strong\u003e1\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003e• Number of Strands: \u003c\/strong\u003e893\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor  inch :\u003c\/strong\u003e  0.670\u003cbr\u003e\u003cstrong\u003e•  Insul Thickness (mil):\u003c\/strong\u003e 65\u003cbr\u003e\u003cstrong\u003e• Approx. OD (inch) :\u003c\/strong\u003e 0.810\u003cbr\u003e\u003cstrong\u003e• Approx. Weight lb\/1000ft : \u003c\/strong\u003e 1179\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C:\u003c\/strong\u003e  0.033\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C :\u003c\/strong\u003e 0.042\u003cbr\u003e\u003cstrong\u003e• Inductive Reactance@ Ω\/1000ft :\u003c\/strong\u003e 0.040\u003cbr\u003e\u003cstrong\u003e• Max Pull Tension lb:  \u003c\/strong\u003e2800\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMin Bending Radius lb: \u003c\/strong\u003e3.2\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C Amp : \u003c\/strong\u003e  310\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C Amp : \u003c\/strong\u003e350\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 325.114px; height: 35.5966px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e457087\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":64113396220273,"sku":"NNC457087","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_1_0d8c21a5-aa83-4825-9c5f-0b35e31b90fa.png?v=1782458455"},{"product_id":"500-awg-1221-strand-bare-copper-xlpe-rw90-machine-flex-power-wire","title":"500 AWG 1221 Strand Bare Copper XLPE RW90 Machine Flex Power Wire","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC44069_1.pdf?v=1782458405\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e500 AWG 1221 Strand Bare Copper XLPE RW90 Machine Flex Power Wire\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eType XHHW-2 \u0026amp; RW90 conductors are primarily used in conduit, cable tray or other recognized raceways for service, feeders, and branch circuit wiring as specified in the National Electric Code (NEC) and the Canadian Electrical Code (CE Code). XHHW-2 \u0026amp; RW90 conductors may be used at conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. Voltage rating for XHHW-2 conductors is 600 volts and 1000 volts. Voltage rating for RW90 conductors is 600 volts. Flexible bare copper stranding allows for ease of installation in locations with limited space, as well as including for use in electrical equipment for industrial facilities with harsh chemical environments, telecommunications applications and data centers.Type XHHW-2 600 Volts or 1000 Volts and Type RW90 600V. Rated 90°C Dry\/Wet,-40°C. Flexible Bare Copper Conductors. Cross-Linked Polyethylene (XLPE) Insulation. Rated High-Heat, Flame, Moisture, Gasoline, Oil and Sunlight Resistant.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e500 AWG Copper RW90 Machine Flex Cable \u003cspan class=\"PDq2pG_selectionAnchor\" aria-hidden=\"true\"\u003e\u003c\/span\u003eXLPE RW90 Flexible Copper Power WireRW90 XLPE Machine Power Cable Flexible 500 AWG Copper RW90 Power Cable XLPE Insulated RW90 Copper Wire Machine Flex XLPE Power Cable RW90 Industrial Flexible Power Wire Flexible XLPE 500 AWG Copper Building Wire Class K Flexible Copper RW90 Cable XHHW-2 \/ RW90 Machine Flex Power Wire \u003cem data-end=\"448\" data-start=\"428\"\u003e(where dual-rated)\u003c\/em\u003e  \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e600V RW90 XLPE Copper Power Wire Industrial XLPE Flexible Copper Cable Flexible Stranded Copper RW90 Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B172 Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test (1\/0 and Larger)\u003cbr\u003e• CSA C22.2 No. 38 Thermoset-insulated wires and cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• CE\/RoHS-2 – The CE Marking has been applied solely to express the conformance to the material restrictions identified in\u003cbr\u003ethe RoHS-2 (2011\/65\/EU) Directive\u003cbr\u003e• Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j)\u003cbr\u003eand the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661\u003cbr\u003e• Sunlight Resistance \u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e1. \u003cstrong\u003eConductors:\u003c\/strong\u003e  8 AWG - 4\/0 AWG: Class K, flexible stranded, soft-drawn bare copper. 250 kcmil - 750 kcmil; Class I, flexible concentric ropelay stranded, soft-drawn bare copper\u003cbr\u003e2. \u003cstrong\u003eInsulation: \u003c\/strong\u003e Black, sunlight, gas, \u0026amp; oil resistant Cross-Linked Polyethylene (XLPE) \u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e  500 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Cond. Number: \u003c\/strong\u003e1\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003e• Number of Strands: \u003c\/strong\u003e1221\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor  inch :\u003c\/strong\u003e 0.858\u003cbr\u003e\u003cstrong\u003e•  Insul Thickness (mil):\u003c\/strong\u003e 70\u003cbr\u003e\u003cstrong\u003e• Approx. OD (inch) :\u003c\/strong\u003e 0.998\u003cbr\u003e\u003cstrong\u003e• Approx. Weight lb\/1000ft : \u003c\/strong\u003e  1632\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C:\u003c\/strong\u003e   0.023\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C :\u003c\/strong\u003e 0.031\u003cbr\u003e\u003cstrong\u003e• Inductive Reactance@ Ω\/1000ft :\u003c\/strong\u003e 0.039\u003cbr\u003e\u003cstrong\u003e• Max Pull Tension lb:  \u003c\/strong\u003e4000\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMin Bending Radius lb: \u003c\/strong\u003e4.0\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C Amp : \u003c\/strong\u003e 380\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C Amp : \u003c\/strong\u003e430\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 325.114px; height: 35.5966px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e459839\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":64113873944945,"sku":"NNC459839","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_1_0d8c21a5-aa83-4825-9c5f-0b35e31b90fa.png?v=1782458455"},{"product_id":"600-awg-1480-strand-bare-copper-xlpe-rw90-machine-flex-power-wire","title":"600 AWG 1480 Strand Bare Copper XLPE RW90 Machine Flex Power Wire","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC44069_1.pdf?v=1782458405\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e600 AWG 1480 Strand Bare Copper XLPE RW90 Machine Flex Power Wire\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eType XHHW-2 \u0026amp; RW90 conductors are primarily used in conduit, cable tray or other recognized raceways for service, feeders, and branch circuit wiring as specified in the National Electric Code (NEC) and the Canadian Electrical Code (CE Code). XHHW-2 \u0026amp; RW90 conductors may be used at conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. Voltage rating for XHHW-2 conductors is 600 volts and 1000 volts. Voltage rating for RW90 conductors is 600 volts. Flexible bare copper stranding allows for ease of installation in locations with limited space, as well as including for use in electrical equipment for industrial facilities with harsh chemical environments, telecommunications applications and data centers.Type XHHW-2 600 Volts or 1000 Volts and Type RW90 600V. Rated 90°C Dry\/Wet,-40°C. Flexible Bare Copper Conductors. Cross-Linked Polyethylene (XLPE) Insulation. Rated High-Heat, Flame, Moisture, Gasoline, Oil and Sunlight Resistant.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e600 AWG Copper RW90 Machine Flex Cable \u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003eXLPE RW90 Flexible Copper Power WireRW90 XLPE Machine Power Cable Flexible 600 AWG Copper RW90 Power Cable XLPE Insulated RW90 Copper Wire Machine Flex XLPE Power Cable RW90 Industrial Flexible Power Wire Flexible XLPE 600 AWG Copper Building Wire Class K Flexible Copper RW90 Cable XHHW-2 \/ RW90 Machine Flex Power Wire \u003cem data-start=\"428\" data-end=\"448\"\u003e(where dual-rated)\u003c\/em\u003e  \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e600V RW90 XLPE Copper Power Wire Industrial XLPE Flexible Copper Cable Flexible Stranded Copper RW90 Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B172 Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test (1\/0 and Larger)\u003cbr\u003e• CSA C22.2 No. 38 Thermoset-insulated wires and cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• CE\/RoHS-2 – The CE Marking has been applied solely to express the conformance to the material restrictions identified in\u003cbr\u003ethe RoHS-2 (2011\/65\/EU) Directive\u003cbr\u003e• Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j)\u003cbr\u003eand the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661\u003cbr\u003e• Sunlight Resistance \u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e1. \u003cstrong\u003eConductors:\u003c\/strong\u003e  8 AWG - 4\/0 AWG: Class K, flexible stranded, soft-drawn bare copper. 250 kcmil - 750 kcmil; Class I, flexible concentric ropelay stranded, soft-drawn bare copper\u003cbr\u003e2. \u003cstrong\u003eInsulation: \u003c\/strong\u003e Black, sunlight, gas, \u0026amp; oil resistant Cross-Linked Polyethylene (XLPE) \u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e  600 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Cond. Number: \u003c\/strong\u003e1\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003e• Number of Strands: \u003c\/strong\u003e1480\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor  inch :\u003c\/strong\u003e  0.963\u003cbr\u003e\u003cstrong\u003e•  Insul Thickness (mil):\u003c\/strong\u003e 85\u003cbr\u003e\u003cstrong\u003e• Approx. OD (inch) :\u003c\/strong\u003e 1.135\u003cbr\u003e\u003cstrong\u003e• Approx. Weight lb\/1000ft :  \u003c\/strong\u003e 2024\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C:\u003c\/strong\u003e    0.019\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C :\u003c\/strong\u003e  0.027\u003cbr\u003e\u003cstrong\u003e• Inductive Reactance@ Ω\/1000ft :\u003c\/strong\u003e 0.039\u003cbr\u003e\u003cstrong\u003e• Max Pull Tension lb:  \u003c\/strong\u003e 4800\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMin Bending Radius lb: \u003c\/strong\u003e5.7\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C Amp :  \u003c\/strong\u003e420\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C Amp : \u003c\/strong\u003e475\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 325.114px; height: 35.5966px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e459840\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":64113905107313,"sku":"NNC459840","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_1_0d8c21a5-aa83-4825-9c5f-0b35e31b90fa.png?v=1782458455"},{"product_id":"750-awg-1850-strand-bare-copper-xlpe-rw90-machine-flex-power-wire","title":"750 AWG 1850 Strand Bare Copper XLPE RW90 Machine Flex Power Wire","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC44069_1.pdf?v=1782458405\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e750 AWG 1850 Strand Bare Copper XLPE RW90 Machine Flex Power Wire\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eType XHHW-2 \u0026amp; RW90 conductors are primarily used in conduit, cable tray or other recognized raceways for service, feeders, and branch circuit wiring as specified in the National Electric Code (NEC) and the Canadian Electrical Code (CE Code). XHHW-2 \u0026amp; RW90 conductors may be used at conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. Voltage rating for XHHW-2 conductors is 600 volts and 1000 volts. Voltage rating for RW90 conductors is 600 volts. Flexible bare copper stranding allows for ease of installation in locations with limited space, as well as including for use in electrical equipment for industrial facilities with harsh chemical environments, telecommunications applications and data centers.Type XHHW-2 600 Volts or 1000 Volts and Type RW90 600V. Rated 90°C Dry\/Wet,-40°C. Flexible Bare Copper Conductors. Cross-Linked Polyethylene (XLPE) Insulation. Rated High-Heat, Flame, Moisture, Gasoline, Oil and Sunlight Resistant.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e750 AWG Copper RW90 Machine Flex Cable \u003cspan class=\"PDq2pG_selectionAnchor\" aria-hidden=\"true\"\u003e\u003c\/span\u003eXLPE RW90 Flexible Copper Power WireRW90 XLPE Machine Power Cable Flexible 750 AWG Copper RW90 Power Cable XLPE Insulated RW90 Copper Wire Machine Flex XLPE Power Cable RW90 Industrial Flexible Power Wire Flexible XLPE 750 AWG Copper Building Wire Class K Flexible Copper RW90 Cable XHHW-2 \/ RW90 Machine Flex Power Wire \u003cem data-end=\"448\" data-start=\"428\"\u003e(where dual-rated)\u003c\/em\u003e  \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e600V RW90 XLPE Copper Power Wire Industrial XLPE Flexible Copper Cable Flexible Stranded Copper RW90 Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B172 Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test (1\/0 and Larger)\u003cbr\u003e• CSA C22.2 No. 38 Thermoset-insulated wires and cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• CE\/RoHS-2 – The CE Marking has been applied solely to express the conformance to the material restrictions identified in\u003cbr\u003ethe RoHS-2 (2011\/65\/EU) Directive\u003cbr\u003e• Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j)\u003cbr\u003eand the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661\u003cbr\u003e• Sunlight Resistance \u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e1. \u003cstrong\u003eConductors:\u003c\/strong\u003e  8 AWG - 4\/0 AWG: Class K, flexible stranded, soft-drawn bare copper. 250 kcmil - 750 kcmil; Class I, flexible concentric ropelay stranded, soft-drawn bare copper\u003cbr\u003e2. \u003cstrong\u003eInsulation: \u003c\/strong\u003e Black, sunlight, gas, \u0026amp; oil resistant Cross-Linked Polyethylene (XLPE) \u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e  750 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Cond. Number: \u003c\/strong\u003e1\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003e• Number of Strands: \u003c\/strong\u003e1850\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor  inch :\u003c\/strong\u003e 1.094\u003cbr\u003e\u003cstrong\u003e•  Insul Thickness (mil):\u003c\/strong\u003e 80\u003cbr\u003e\u003cstrong\u003e• Approx. OD (inch) :\u003c\/strong\u003e  1.266\u003cbr\u003e\u003cstrong\u003e• Approx. Weight lb\/1000ft : \u003c\/strong\u003e2553\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C:\u003c\/strong\u003e 0.016\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C :\u003c\/strong\u003e 0.024\u003cbr\u003e\u003cstrong\u003e• Inductive Reactance@ Ω\/1000ft :\u003c\/strong\u003e 0.038\u003cbr\u003e\u003cstrong\u003e• Max Pull Tension lb: \u003c\/strong\u003e6000\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMin Bending Radius lb: \u003c\/strong\u003e6.3\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C Amp :\u003c\/strong\u003e 475\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C Amp : \u003c\/strong\u003e535\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"width: 324px; height: 35.5966px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 227.281px;\"\u003e\u003cstrong\u003eSouthwire\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 96.719px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e138906\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":64113914151281,"sku":"NNC138906","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_1_0d8c21a5-aa83-4825-9c5f-0b35e31b90fa.png?v=1782458455"},{"product_id":"1000-awg-2527-strand-bare-copper-xlpe-rw90-machine-flex-power-wire","title":"1000 AWG 2527 Strand Bare Copper XLPE RW90 Machine Flex Power Wire","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC44069_1.pdf?v=1782458405\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e1000 AWG 2527 Strand Bare Copper XLPE RW90 Machine Flex Power Wire\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eType XHHW-2 \u0026amp; RW90 conductors are primarily used in conduit, cable tray or other recognized raceways for service, feeders, and branch circuit wiring as specified in the National Electric Code (NEC) and the Canadian Electrical Code (CE Code). XHHW-2 \u0026amp; RW90 conductors may be used at conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. Voltage rating for XHHW-2 conductors is 600 volts and 1000 volts. Voltage rating for RW90 conductors is 600 volts. Flexible bare copper stranding allows for ease of installation in locations with limited space, as well as including for use in electrical equipment for industrial facilities with harsh chemical environments, telecommunications applications and data centers.Type XHHW-2 600 Volts or 1000 Volts and Type RW90 600V. Rated 90°C Dry\/Wet,-40°C. Flexible Bare Copper Conductors. Cross-Linked Polyethylene (XLPE) Insulation. Rated High-Heat, Flame, Moisture, Gasoline, Oil and Sunlight Resistant.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e1000 AWG Copper RW90 Machine Flex Cable \u003cspan class=\"PDq2pG_selectionAnchor\" aria-hidden=\"true\"\u003e\u003c\/span\u003eXLPE RW90 Flexible Copper Power WireRW90 XLPE Machine Power Cable Flexible 1000 AWG Copper RW90 Power Cable XLPE Insulated RW90 Copper Wire Machine Flex XLPE Power Cable RW90 Industrial Flexible Power Wire Flexible XLPE 1000 AWG Copper Building Wire Class K Flexible Copper RW90 Cable XHHW-2 \/ RW90 Machine Flex Power Wire \u003cem data-end=\"448\" data-start=\"428\"\u003e(where dual-rated)\u003c\/em\u003e  \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e600V RW90 XLPE Copper Power Wire Industrial XLPE Flexible Copper Cable Flexible Stranded Copper RW90 Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B172 Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test (1\/0 and Larger)\u003cbr\u003e• CSA C22.2 No. 38 Thermoset-insulated wires and cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• CE\/RoHS-2 – The CE Marking has been applied solely to express the conformance to the material restrictions identified in\u003cbr\u003ethe RoHS-2 (2011\/65\/EU) Directive\u003cbr\u003e• Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j)\u003cbr\u003eand the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661\u003cbr\u003e• Sunlight Resistance \u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e1. \u003cstrong\u003eConductors:\u003c\/strong\u003e  8 AWG - 4\/0 AWG: Class K, flexible stranded, soft-drawn bare copper. 250 kcmil - 750 kcmil; Class I, flexible concentric ropelay stranded, soft-drawn bare copper\u003cbr\u003e2. \u003cstrong\u003eInsulation: \u003c\/strong\u003e Black, sunlight, gas, \u0026amp; oil resistant Cross-Linked Polyethylene (XLPE) \u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e  1000 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Cond. Number: \u003c\/strong\u003e1\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003e• Number of Strands: \u003c\/strong\u003e2527\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor  inch :\u003c\/strong\u003e 1.190\u003cbr\u003e\u003cstrong\u003e•  Insul Thickness (mil):\u003c\/strong\u003e 80\u003cbr\u003e\u003cstrong\u003e• Approx. OD (inch) :\u003c\/strong\u003e   1.350\u003cbr\u003e\u003cstrong\u003e• Approx. Weight lb\/1000ft : \u003c\/strong\u003e3211\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C:\u003c\/strong\u003e  0.012\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C :\u003c\/strong\u003e  0.020\u003cbr\u003e\u003cstrong\u003e• Inductive Reactance@ Ω\/1000ft :\u003c\/strong\u003e 0.037\u003cbr\u003e\u003cstrong\u003e• Max Pull Tension lb: \u003c\/strong\u003e8000\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMin Bending Radius lb: \u003c\/strong\u003e6.7\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C Amp :\u003c\/strong\u003e 545\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C Amp : \u003c\/strong\u003e615\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":64113923555697,"sku":"NNC589628","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_1_0d8c21a5-aa83-4825-9c5f-0b35e31b90fa.png?v=1782458455"}],"url":"https:\/\/nassaunationalcable.com\/en-ca\/collections\/copper-xlpe-rw90-machine-flex-power-wire.oembed?page=2","provider":"NassauNationalCable","version":"1.0","type":"link"}