{"title":"Copper EPR \/ PVC Concentric Neutral MV-90 Primary UD Cable 5 kV - 46 kV","description":"","products":[{"product_id":"copper-epr-pvc-concentric-neutral-mv-90-primary-ud-cable-5-kv-46-kv","title":"Copper EPR \/ PVC Concentric Neutral MV-90 Primary UD Cable 5 kV - 46 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_1__removed.pdf?v=1746173120\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eCopper EPR \/ PVC Concentric Neutral MV-90 Primary UD Cable 5 kV - 46 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eCopper EPR MV-90 cable, PVC concentric neutral MV-90, Medium voltage underground distribution cable, EPR insulated primary UD cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e Specifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation \u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation: \u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral: \u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e A suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55207329137009,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_c17007bd-0311-4fd0-b6f8-3a10b32dcbc3.png?v=1763024673"},{"product_id":"2-awg-7-str-copper-primary-ud-cable-14-awg-1-3-neutral-epr-pvc-mv-90-100-175-mil-15-kv","title":"2 AWG 7 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_1__removed.pdf?v=1746173120\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2 AWG 7 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e2 AWG Copper EPR MV-90 cable, 2 AWG PVC concentric neutral MV-90, Medium voltage underground distribution cable, 2 AWG EPR insulated primary UD cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 7\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.68\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 6\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 14 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e  1.05\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e646\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55207341425009,"sku":"NNC027EPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_b32e67fa-8bd1-4023-892f-36fe115cc28b.png?v=1763024676"},{"product_id":"1-awg-19-str-copper-primary-ud-cable-14-awg-1-3-neutral-epr-pvc-mv-90-100-175-mil-15-kv","title":"1 AWG 19 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_1__removed.pdf?v=1746173120\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1 AWG 19 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1 AWG Copper EPR MV-90 cable, 1 AWG PVC concentric neutral MV-90, Medium voltage underground distribution cable, 1 AWG EPR insulated primary UD cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.71\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 7\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 14 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.09\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 733\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55207341687153,"sku":"NNC119EPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_951123ef-3301-4154-9ba6-09fd8a057cba.png?v=1763024677"},{"product_id":"1-0-awg-19-str-copper-primary-ud-cable-14-awg-1-3-neutral-epr-pvc-mv-90-100-175-mil-15-kv","title":"1\/0 AWG 19 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_1__removed.pdf?v=1746173120\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1\/0 AWG 19 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1\/0 AWG Copper EPR MV-90 cable, 1\/0 AWG PVC concentric neutral MV-90, Medium voltage underground distribution cable, 1\/0 AWG EPR insulated primary UD cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.75\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e  9\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 14 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.13\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e  850\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55207342735729,"sku":"NNC1\/0EPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_26fb2c19-508a-42df-96e1-b0395b81c00a.png?v=1763024677"},{"product_id":"2-0-awg-19-str-copper-primary-ud-cable-14-awg-1-3-neutral-epr-pvc-mv-90-100-175-mil-15-kv","title":"2\/0 AWG 19 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_1__removed.pdf?v=1746173120\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e2\/0 AWG 19 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e2\/0 AWG Copper EPR MV-90 cable, 2\/0 AWG PVC concentric neutral MV-90, Medium voltage underground distribution cable, 2\/0 AWG EPR insulated primary UD cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.80\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 11\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 14 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.17\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 987\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55207344275825,"sku":"NNC2\/0EPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_b78c4ac5-4369-4288-9274-ded2593bcb4e.png?v=1763024679"},{"product_id":"3-0-awg-19-str-copper-primary-ud-cable-14-awg-1-3-neutral-epr-pvc-mv-90-100-175-mil-15-kv","title":"3\/0 AWG 19 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_1__removed.pdf?v=1746173120\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e3\/0 AWG 19 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e3\/0 AWG Copper EPR MV-90 cable, 3\/0 AWG PVC concentric neutral MV-90, Medium voltage underground distribution cable, 3\/0 AWG EPR insulated primary UD cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 3\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.85\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 14\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 14 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.22\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 1163\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55207345848689,"sku":"NNC3\/0EPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_ba3870dd-689e-482c-b879-0d4dc8ec40d1.png?v=1763024680"},{"product_id":"4-0-awg-19-str-copper-primary-ud-cable-14-awg-1-3-neutral-epr-pvc-mv-90-100-175-mil-15-kv","title":"4\/0 AWG 19 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_1__removed.pdf?v=1746173120\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e4\/0 AWG 19 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e4\/0 AWG Copper EPR MV-90 cable, 4\/0 AWG PVC concentric neutral MV-90, Medium voltage underground distribution cable, 4\/0 AWG EPR insulated primary UD cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 4\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.90\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e  18\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 14 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.28\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 1385\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55207346897265,"sku":"NNC4\/0EPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_8e0f08fa-97ca-4946-90be-7804b83ad0d3.png?v=1763024680"},{"product_id":"250-mcm-37-str-copper-primary-ud-cable-12-awg-1-3-neutral-epr-pvc-mv-90-100-175-mil-15-kv","title":"250 MCM 37 Str Copper Primary UD Cable 12 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_1__removed.pdf?v=1746173120\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e250 MCM 37 Str Copper Primary UD Cable 12 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e250 MCM  Copper EPR MV-90 cable, 250 MCM  PVC concentric neutral MV-90, Medium voltage underground distribution cable, 250 MCM EPR insulated primary UD cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 250 MCM \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 37\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.96\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 13\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e  12 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.37\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 1576\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55207348011377,"sku":"NNC1250EPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_4576faaf-df9a-4879-bca9-2004d093e1b0.png?v=1763024682"},{"product_id":"350-mcm-37-str-copper-primary-ud-cable-12-awg-1-3-neutral-epr-pvc-mv-90-100-175-mil-15-kv","title":"350 MCM 37 Str Copper Primary UD Cable 12 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_1__removed.pdf?v=1746173120\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e350 MCM 37 Str Copper Primary UD Cable 12 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e350 MCM Copper EPR MV-90 cable, 350 MCM  PVC concentric neutral MV-90, Medium voltage underground distribution cable, 350 MCM EPR insulated primary UD cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 350 MCM \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 37\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e  1.06\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 18\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e  12 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.49\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e  2075\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55207353975153,"sku":"NNC1350EPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_86793860-d432-4629-81c4-8a09eb8b43f6.png?v=1763024684"},{"product_id":"500-mcm-37-str-copper-primary-ud-cable-10-awg-1-3-neutral-epr-pvc-mv-90-100-175-mil-15-kv","title":"500 MCM 37 Str Copper Primary UD Cable 10 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_1__removed.pdf?v=1746173120\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e500 MCM 37 Str Copper Primary UD Cable 10 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e500 MCM Copper EPR MV-90 cable, 500 MCM  PVC concentric neutral MV-90, Medium voltage underground distribution cable, 500 MCM EPR insulated primary UD cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 500 MCM \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 37\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e   1.19\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 17\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 10 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.66\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 2814\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55207364690289,"sku":"NNC1500EPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_0a6364a7-99b6-4bc0-acf6-7eab85a46aed.png?v=1763024689"},{"product_id":"750-mcm-61-str-copper-primary-ud-cable-9-awg-1-3-neutral-epr-pvc-mv-90-100-175-mil-15-kv","title":"750 MCM 61 Str Copper Primary UD Cable 9 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_1__removed.pdf?v=1746173120\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e750 MCM 61 Str Copper Primary UD Cable 9 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e750 MCM Copper EPR MV-90 cable, 750 MCM  PVC concentric neutral MV-90, Medium voltage underground distribution cable, 750 MCM EPR insulated primary UD cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 750 MCM \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e  61\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.38\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e  20\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e  9 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e  110\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e  1.94\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e  4095\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55207411351921,"sku":"NNC1750EPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_e65ceeca-d936-4dad-a0fc-93081175344d.png?v=1763024693"},{"product_id":"1000-mcm-61-str-copper-primary-ud-cable-9-awg-1-3-neutral-epr-pvc-mv-90-100-175-mil-15-kv","title":"1000 MCM 61 Str Copper Primary UD Cable 9 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_1__removed.pdf?v=1746173120\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1000 MCM 61 Str Copper Primary UD Cable 9 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1000 MCM Copper EPR MV-90 cable, 1000 MCM PVC concentric neutral MV-90, Medium voltage underground distribution cable, 1000 MCM EPR insulated primary UD cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1000 MCM \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e  61\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e  1.53\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e   26\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e  9 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e  110\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e  2.12\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e  5268\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55207416922481,"sku":"NNC10001EPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_42115aa5-a75a-4d61-83aa-3cc365715f10.png?v=1763024693"},{"product_id":"2-awg-7-str-copper-primary-ud-cable-14-awg-full-neutral-epr-pvc-mv-90-100-175-mil-15-kv","title":"2 AWG 7 Str Copper Primary UD Cable 14 AWG Full Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_1__removed.pdf?v=1746173120\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2 AWG 7 Str Copper Primary UD Cable 14 AWG Full Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e2 AWG Copper EPR MV-90 cable, 2 AWG PVC concentric neutral MV-90, Medium voltage underground distribution cable, 2 AWG EPR insulated primary UD cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 7\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e  0.68\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 16\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003c\/strong\u003e\u003cspan\u003e  14 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.05\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 779\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55207423705457,"sku":"NNC271EPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_2b020c8c-b1d6-46ee-8719-53162c058f1d.png?v=1763024695"},{"product_id":"1-awg-19-str-copper-primary-ud-cable-12-awg-full-neutral-epr-pvc-mv-90-100-175-mil-15-kv","title":"1 AWG 19 Str Copper Primary UD Cable 12 AWG Full Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_1__removed.pdf?v=1746173120\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1 AWG 19 Str Copper Primary UD Cable 12 AWG Full Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1 AWG Copper EPR MV-90 cable, 1 AWG PVC concentric neutral MV-90, Medium voltage underground distribution cable, 1 AWG EPR insulated primary UD cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.71\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e  13\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 12 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.12\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 921\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55207425966449,"sku":"NNC1109EPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_a030e5ed-b002-47a5-b534-784fe06c61f7.png?v=1763024696"},{"product_id":"1-0-awg-19-str-copper-primary-ud-cable-12-awg-full-neutral-epr-pvc-mv-90-100-175-mil-15-kv","title":"1\/0 AWG 19 Str Copper Primary UD Cable 12 AWG Full Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_1__removed.pdf?v=1746173120\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1\/0 AWG 19 Str Copper Primary UD Cable 12 AWG Full Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1\/0 AWG Copper EPR MV-90 cable, 1\/0 AWG PVC concentric neutral MV-90, Medium voltage underground distribution cable, 1\/0 AWG EPR insulated primary UD cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.75\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e  16\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 12 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.16\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 1075\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55207429144945,"sku":"NNC1\/019EPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_0cd6de3d-788a-42e7-b3d9-c8afee497411.png?v=1763024696"},{"product_id":"2-0-awg-19-str-copper-primary-ud-cable-10-awg-full-neutral-epr-pvc-mv-90-100-175-mil-15-kv","title":"2\/0 AWG 19 Str Copper Primary UD Cable 10 AWG Full Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_1__removed.pdf?v=1746173120\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2\/0 AWG 19 Str Copper Primary UD Cable 10 AWG Full Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e2\/0 AWG Copper EPR MV-90 cable, 2\/0 AWG PVC concentric neutral MV-90, Medium voltage underground distribution cable, 2\/0 AWG EPR insulated primary UD cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e  0.80\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e  13\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003c\/strong\u003e\u003cspan\u003e  10 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e  1.25\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 1292\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55207432814961,"sku":"NNC2\/010EPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_a0016fce-c116-49c7-a814-cd84ebcf3e4b.png?v=1763024698"},{"product_id":"3-0-awg-19-str-copper-primary-ud-cable-10-awg-full-neutral-epr-pvc-mv-90-100-175-mil-15-kv","title":"3\/0 AWG 19 Str Copper Primary UD Cable 10 AWG Full Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_1__removed.pdf?v=1746173120\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e3\/0 AWG 19 Str Copper Primary UD Cable 10 AWG Full Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e3\/0 AWG Copper EPR MV-90 cable, 3\/0 AWG PVC concentric neutral MV-90, Medium voltage underground distribution cable, 3\/0 AWG EPR insulated primary UD cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 3\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.85\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e  16\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003c\/strong\u003e\u003cspan\u003e  10 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e  1.30\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 1530\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55207442940273,"sku":"NNC3\/010EPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_add5b168-d3f6-4e4c-afa9-5974799d4d19.png?v=1763024698"},{"product_id":"4-0-awg-19-str-copper-primary-ud-cable-9-awg-full-neutral-epr-pvc-mv-90-100-175-mil-15-kv","title":"4\/0 AWG 19 Str Copper Primary UD Cable 9 AWG Full Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_1__removed.pdf?v=1746173120\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e4\/0 AWG 19 Str Copper Primary UD Cable 9 AWG Full Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e4\/0 AWG Copper EPR MV-90 cable, 4\/0 AWG PVC concentric neutral MV-90, Medium voltage underground distribution cable, 4\/0 AWG EPR insulated primary UD cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 4\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e  0.90\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e  16\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003c\/strong\u003e\u003cspan\u003e  9 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e  1.38\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e  1842\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55207461519729,"sku":"NNC4\/09EPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_774b1366-f197-4d1e-96a2-da747bcba48d.png?v=1763024699"},{"product_id":"250-mcm-37-str-copper-primary-ud-cable-10-awg-full-neutral-epr-pvc-mv-90-100-175-mil-15-kv","title":"250 MCM 37 Str Copper Primary UD Cable 10 AWG Full Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_1__removed.pdf?v=1746173120\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e250 MCM 37 Str Copper Primary UD Cable 10 AWG Full Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e250 MCM Copper EPR MV-90 cable, 250 MCM PVC concentric neutral MV-90, Medium voltage underground distribution cable, 250 MCM EPR insulated primary UD cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 250 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 37\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e   0.96\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 25\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 10 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 1.41\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft: \u003c\/strong\u003e\u003cspan\u003e2151\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55207479411057,"sku":"NNC2501EPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_2fc2e102-064a-4d4b-8145-35652dddb131.png?v=1763024701"},{"product_id":"350-mcm-37-str-copper-primary-ud-cable-8-awg-full-neutral-epr-pvc-mv-90-100-175-mil-15-kv","title":"350 MCM 37 Str Copper Primary UD Cable 8 AWG Full Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_1__removed.pdf?v=1746173120\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e350 MCM 37 Str Copper Primary UD Cable 8 AWG Full Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e350 MCM Copper EPR MV-90 cable, 350 MCM PVC concentric neutral MV-90, Medium voltage underground distribution cable, 350 MCM EPR insulated primary UD cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 350 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 37\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.06\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 22\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003c\/strong\u003e\u003cspan\u003e  8 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 1.59\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft: \u003c\/strong\u003e2890\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55207481770353,"sku":"NNC3501EPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_4ca7336b-47c7-44fa-a21e-f3afdac2c6ba.png?v=1763024701"},{"product_id":"500-mcm-37-str-copper-primary-ud-cable-8-awg-full-neutral-epr-pvc-mv-90-100-175-mil-15-kv","title":"500 MCM 37 Str Copper Primary UD Cable 8 AWG Full Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_1__removed.pdf?v=1746173120\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e500 MCM 37 Str Copper Primary UD Cable 8 AWG Full Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e500 MCM Copper EPR MV-90 cable, 500 MCM PVC concentric neutral MV-90, Medium voltage underground distribution cable, 500 MCM EPR insulated primary UD cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 500 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 37\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e  1.19\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 31\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003c\/strong\u003e\u003cspan\u003e  8 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 110\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 1.78\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft: \u003c\/strong\u003e4020\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55207488553329,"sku":"NNC5001EPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_4daa3461-448b-48ba-abf5-3a9893ca6462.png?v=1763024703"},{"product_id":"2-awg-7-str-copper-primary-ud-cable-14-awg-1-3-neutral-epr-pvc-mv-90-133-220-mil-15-kv","title":"2 AWG 7 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_1__removed.pdf?v=1746173120\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2 AWG 7 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e2 AWG Copper EPR MV-90 cable, 2 AWG PVC concentric neutral MV-90, Medium voltage underground distribution cable, 2 AWG EPR insulated primary UD cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 7\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.77\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 6\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 14 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e  80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 1.14\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e  721\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55208381284721,"sku":"NNC27MEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_4daa3461-448b-48ba-abf5-3a9893ca6462.png?v=1763024703"},{"product_id":"1-awg-19-str-copper-primary-ud-cable-14-awg-1-3-neutral-epr-pvc-mv-90-133-220-mil-15-kv","title":"1 AWG 19 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_1__removed.pdf?v=1746173120\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1 AWG 19 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1 AWG Copper EPR MV-90 cable, 1 AWG PVC concentric neutral MV-90, Medium voltage underground distribution cable, 1 AWG EPR insulated primary UD cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.81\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 7\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 14 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e  80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e  1.18\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e 812\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55208384725361,"sku":"NNC119MEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_4daa3461-448b-48ba-abf5-3a9893ca6462.png?v=1763024703"},{"product_id":"1-0-awg-19-str-copper-primary-ud-cable-14-awg-1-3-neutral-epr-pvc-mv-90-133-220-mil-15-kv","title":"1\/0 AWG 19 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_1__removed.pdf?v=1746173120\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1\/0 AWG 19 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1\/0 AWG Copper EPR MV-90 cable, 1\/0 AWG PVC concentric neutral MV-90, Medium voltage underground distribution cable, 1\/0 AWG EPR insulated primary UD cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e  0.85\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e  9\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 14 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e  80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 1.22\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e 932\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55208395932017,"sku":"NNC1\/0MEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_4daa3461-448b-48ba-abf5-3a9893ca6462.png?v=1763024703"},{"product_id":"2-0-awg-19-str-copper-primary-ud-cable-14-awg-1-3-neutral-epr-pvc-mv-90-133-220-mil-15-kv","title":"2\/0 AWG 19 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_1__removed.pdf?v=1746173120\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2\/0 AWG 19 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e2\/0 AWG Copper EPR MV-90 cable, 2\/0 AWG PVC concentric neutral MV-90, Medium voltage underground distribution cable, 2\/0 AWG EPR insulated primary UD cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.89 \u003cbr\u003e\u003cstrong\u003e• Number of Wires: \u003c\/strong\u003e11\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 14 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e  80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 1.26\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e  1072\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55208399110513,"sku":"NNC2\/0MEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_4daa3461-448b-48ba-abf5-3a9893ca6462.png?v=1763024703"},{"product_id":"3-0-awg-19-str-copper-primary-ud-cable-14-awg-1-3-neutral-epr-pvc-mv-90-133-220-mil-15-kv","title":"3\/0 AWG 19 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_1__removed.pdf?v=1746173120\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e3\/0 AWG 19 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e3\/0 AWG Copper EPR MV-90 cable, 3\/0 AWG PVC concentric neutral MV-90, Medium voltage underground distribution cable, 3\/0 AWG EPR insulated primary UD cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 3\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.94\u003cbr\u003e\u003cstrong\u003e• Number of Wires: \u003c\/strong\u003e14\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 14 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e  80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 1.31\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e 1252\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55208405434737,"sku":"NNC3\/0MEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_4daa3461-448b-48ba-abf5-3a9893ca6462.png?v=1763024703"},{"product_id":"4-0-awg-19-str-copper-primary-ud-cable-14-awg-1-3-neutral-epr-pvc-mv-90-133-220-mil-15-kv","title":"4\/0 AWG 19 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_1__removed.pdf?v=1746173120\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e4\/0 AWG 19 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e4\/0 AWG Copper EPR MV-90 cable, 4\/0 AWG PVC concentric neutral MV-90, Medium voltage underground distribution cable, 4\/0 AWG EPR insulated primary UD cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 4\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.00\u003cbr\u003e\u003cstrong\u003e• Number of Wires: \u003c\/strong\u003e18\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 14 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e  80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 1.37\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e 1478\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55208407269745,"sku":"NNC4\/0MEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_4daa3461-448b-48ba-abf5-3a9893ca6462.png?v=1763024703"},{"product_id":"250-mcm-37-str-copper-primary-ud-cable-12-awg-1-3-neutral-epr-pvc-mv-90-133-220-mil-15-kv","title":"250 MCM 37 Str Copper Primary UD Cable 12 AWG 1\/3 Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_1__removed.pdf?v=1746173120\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e250 MCM 37 Str Copper Primary UD Cable 12 AWG 1\/3 Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e250 MCM  Copper EPR MV-90 cable, 250 MCM  PVC concentric neutral MV-90, Medium voltage underground distribution cable, 250 MCM  EPR insulated primary UD cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 250 MCM \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 37\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e  1.05\u003cbr\u003e\u003cstrong\u003e• Number of Wires: \u003c\/strong\u003e13\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e  12 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e  80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 1.48\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e 1698\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55208412709233,"sku":"NNC250MEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_4daa3461-448b-48ba-abf5-3a9893ca6462.png?v=1763024703"},{"product_id":"350-mcm-37-str-copper-primary-ud-cable-12-awg-1-3-neutral-epr-pvc-mv-90-133-220-mil-15-kv","title":"350 MCM 37 Str Copper Primary UD Cable 12 AWG 1\/3 Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_1__removed.pdf?v=1746173120\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e350 MCM 37 Str Copper Primary UD Cable 12 AWG 1\/3 Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e350 MCM  Copper EPR MV-90 cable, 350 MCM  PVC concentric neutral MV-90, Medium voltage underground distribution cable, 350 MCM  EPR insulated primary UD cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 350 MCM \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 37\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e   1.16\u003cbr\u003e\u003cstrong\u003e• Number of Wires: \u003c\/strong\u003e18\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e  12 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e  80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 1.58\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e  2182\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55208413888881,"sku":"NNC350MEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_4daa3461-448b-48ba-abf5-3a9893ca6462.png?v=1763024703"},{"product_id":"500-mcm-37-str-copper-primary-ud-cable-10-awg-1-3-neutral-epr-pvc-mv-90-133-220-mil-15-kv","title":"500 MCM 37 Str Copper Primary UD Cable 10 AWG 1\/3 Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_1__removed.pdf?v=1746173120\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e500 MCM 37 Str Copper Primary UD Cable 10 AWG 1\/3 Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e500 MCM Copper EPR MV-90 cable, 500 MCM  PVC concentric neutral MV-90, Medium voltage underground distribution cable, 500 MCM  EPR insulated primary UD cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 500 MCM \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 37\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.28\u003cbr\u003e\u003cstrong\u003e• Number of Wires: \u003c\/strong\u003e17\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 10 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 110\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e  1.82\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e  3039\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55208416641393,"sku":"NNC500MEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_4daa3461-448b-48ba-abf5-3a9893ca6462.png?v=1763024703"},{"product_id":"750-mcm-61-str-copper-primary-ud-cable-9-awg-1-3-neutral-epr-pvc-mv-90-133-220-mil-15-kv","title":"750 MCM 61 Str Copper Primary UD Cable 9 AWG 1\/3 Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_1__removed.pdf?v=1746173120\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e750 MCM 61 Str Copper Primary UD Cable 9 AWG 1\/3 Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e750 MCM Copper EPR MV-90 cable, 750 MCM  PVC concentric neutral MV-90, Medium voltage underground distribution cable, 750 MCM  EPR insulated primary UD cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 750 MCM \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 61\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.47\u003cbr\u003e\u003cstrong\u003e• Number of Wires: \u003c\/strong\u003e20\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 9 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 110\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e  2.03\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e  4232\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55208421196145,"sku":"NNC750MEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_4daa3461-448b-48ba-abf5-3a9893ca6462.png?v=1763024703"},{"product_id":"1000-mcm-61-str-copper-primary-ud-cable-9-awg-1-3-neutral-epr-pvc-mv-90-133-220-mil-15-kv","title":"1000 MCM 61 Str Copper Primary UD Cable 9 AWG 1\/3 Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_1__removed.pdf?v=1746173120\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1000 MCM 61 Str Copper Primary UD Cable 9 AWG 1\/3 Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1000 MCM Copper EPR MV-90 cable, 1000 MCM  PVC concentric neutral MV-90, Medium voltage underground distribution cable, 1000 MCM  EPR insulated primary UD cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1000 MCM \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 61\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.62\u003cbr\u003e\u003cstrong\u003e• Number of Wires: \u003c\/strong\u003e26\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 9 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 110\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e   2.21\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e  5418\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55210684645745,"sku":"NNC1000MEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_4daa3461-448b-48ba-abf5-3a9893ca6462.png?v=1763024703"},{"product_id":"2-awg-7-str-copper-primary-ud-cable-14-awg-full-neutral-epr-pvc-mv-90-133-220-mil-15-kv","title":"2 AWG 7 Str Copper Primary UD Cable 14 AWG Full Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_1__removed.pdf?v=1746173120\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2 AWG 7 Str Copper Primary UD Cable 14 AWG Full Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e2 AWG Copper EPR MV-90 cable, 2 AWG PVC concentric neutral MV-90, Medium voltage underground distribution cable, 2 AWG EPR insulated primary UD cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e  7\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.77\u003cbr\u003e\u003cstrong\u003e• Number of Wires: \u003c\/strong\u003e16\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 14 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 1.14\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e 855\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55210687365489,"sku":"NNC207MEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_4daa3461-448b-48ba-abf5-3a9893ca6462.png?v=1763024703"},{"product_id":"1-awg-19-str-copper-primary-ud-cable-12-awg-full-neutral-epr-pvc-mv-90-133-220-mil-15-kv","title":"1 AWG 19 Str Copper Primary UD Cable 12 AWG Full Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_1__removed.pdf?v=1746173120\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1 AWG 19 Str Copper Primary UD Cable 12 AWG Full Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1 AWG Copper EPR MV-90 cable, 1 AWG PVC concentric neutral MV-90, Medium voltage underground distribution cable, 1 AWG EPR insulated primary UD cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.81\u003cbr\u003e\u003cstrong\u003e• Number of Wires: \u003c\/strong\u003e13\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 12 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 1.21\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e  1000\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55210690380145,"sku":"NNC1192MEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_4daa3461-448b-48ba-abf5-3a9893ca6462.png?v=1763024703"},{"product_id":"1-0-awg-19-str-copper-primary-ud-cable-12-awg-full-neutral-epr-pvc-mv-90-133-220-mil-15-kv","title":"1\/0 AWG 19 Str Copper Primary UD Cable 12 AWG Full Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_1__removed.pdf?v=1746173120\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1\/0 AWG 19 Str Copper Primary UD Cable 12 AWG Full Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1\/0 AWG Copper EPR MV-90 cable, 1\/0 AWG PVC concentric neutral MV-90, Medium voltage underground distribution cable, 1\/0 AWG EPR insulated primary UD cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.85\u003cbr\u003e\u003cstrong\u003e• Number of Wires: \u003c\/strong\u003e16\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 12 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e  1.25\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e 1157\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55210692903281,"sku":"NNC1\/019MEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_4daa3461-448b-48ba-abf5-3a9893ca6462.png?v=1763024703"},{"product_id":"2-0-awg-19-str-copper-primary-ud-cable-10-awg-full-neutral-epr-pvc-mv-90-133-220-mil-15-kv","title":"2\/0 AWG 19 Str Copper Primary UD Cable 10 AWG Full Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_1__removed.pdf?v=1746173120\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2\/0 AWG 19 Str Copper Primary UD Cable 10 AWG Full Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e2\/0 AWG Copper EPR MV-90 cable, 2\/0 AWG PVC concentric neutral MV-90, Medium voltage underground distribution cable, 2\/0 AWG EPR insulated primary UD cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.89\u003cbr\u003e\u003cstrong\u003e• Number of Wires: \u003c\/strong\u003e13\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 10 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 1.34\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e 1377\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55210696016241,"sku":"NNC2\/019MEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_4daa3461-448b-48ba-abf5-3a9893ca6462.png?v=1763024703"},{"product_id":"3-0-awg-19-str-copper-primary-ud-cable-10-awg-full-neutral-epr-pvc-mv-90-133-220-mil-15-kv","title":"3\/0 AWG 19 Str Copper Primary UD Cable 10 AWG Full Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_1__removed.pdf?v=1746173120\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e3\/0 AWG 19 Str Copper Primary UD Cable 10 AWG Full Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e3\/0 AWG Copper EPR MV-90 cable, 3\/0 AWG PVC concentric neutral MV-90, Medium voltage underground distribution cable, 3\/0 AWG EPR insulated primary UD cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 3\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.94\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 16\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 10 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e  1.39\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e  1618\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55210700636529,"sku":"NNC3\/019MEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_4daa3461-448b-48ba-abf5-3a9893ca6462.png?v=1763024703"},{"product_id":"4-0-awg-19-str-copper-primary-ud-cable-9-awg-full-neutral-epr-pvc-mv-90-133-220-mil-15-kv","title":"4\/0 AWG 19 Str Copper Primary UD Cable 9 AWG Full Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_1__removed.pdf?v=1746173120\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e4\/0 AWG 19 Str Copper Primary UD Cable 9 AWG Full Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e4\/0 AWG Copper EPR MV-90 cable, 4\/0 AWG PVC concentric neutral MV-90, Medium voltage underground distribution cable, 4\/0 AWG EPR insulated primary UD cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 4\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.00\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 16\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 9 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e  1.47\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e 1935\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55210704339313,"sku":"NNC4\/019MEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_4daa3461-448b-48ba-abf5-3a9893ca6462.png?v=1763024703"},{"product_id":"250-mcm-37-str-copper-primary-ud-cable-10-awg-full-neutral-epr-pvc-mv-90-133-220-mil-15-kv","title":"250 MCM 37 Str Copper Primary UD Cable 10 AWG Full Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_1__removed.pdf?v=1746173120\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e250 MCM 37 Str Copper Primary UD Cable 10 AWG Full Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e250 MCM Copper EPR MV-90 cable, 250 MCM PVC concentric neutral MV-90, Medium voltage underground distribution cable, 250 MCM EPR insulated primary UD cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 250 MCM \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 37\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.05\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 25\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 10 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e  1.52\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e 2273\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55210711941489,"sku":"NNC0250MEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_4daa3461-448b-48ba-abf5-3a9893ca6462.png?v=1763024703"},{"product_id":"350-mcm-37-str-copper-primary-ud-cable-8-awg-full-neutral-epr-pvc-mv-90-133-220-mil-15-kv","title":"350 MCM 37 Str Copper Primary UD Cable 8 AWG Full Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_1__removed.pdf?v=1746173120\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e350 MCM 37 Str Copper Primary UD Cable 8 AWG Full Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e350 MCM Copper EPR MV-90 cable, 350 MCM PVC concentric neutral MV-90, Medium voltage underground distribution cable, 350 MCM EPR insulated primary UD cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 350 MCM \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 37\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e  1.16\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 22\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 8 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e  1.68\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e  2997\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55210714988913,"sku":"NNC0350MEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_4daa3461-448b-48ba-abf5-3a9893ca6462.png?v=1763024703"},{"product_id":"500-mcm-37-str-copper-primary-ud-cable-8-awg-full-neutral-epr-pvc-mv-90-133-220-mil-15-kv","title":"500 MCM 37 Str Copper Primary UD Cable 8 AWG Full Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_1__removed.pdf?v=1746173120\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e500 MCM 37 Str Copper Primary UD Cable 8 AWG Full Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e500 MCM Copper EPR MV-90 cable, 500 MCM PVC concentric neutral MV-90, Medium voltage underground distribution cable, 500 MCM EPR insulated primary UD cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 500 MCM \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 37\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e  1.28\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e  31\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 8 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e  110\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 1.87\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e  4143\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55210722263409,"sku":"NNC0500MEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_4daa3461-448b-48ba-abf5-3a9893ca6462.png?v=1763024703"},{"product_id":"1-awg-19-str-copper-primary-ud-cable-14-awg-1-3-neutral-epr-pvc-mv-90-100-260-mil-25-kv","title":"1 AWG 19 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 260 mil 25 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_1__removed.pdf?v=1746173120\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1 AWG 19 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 260 mil 25 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1 AWG Copper EPR MV-90 cable, 1 AWG PVC concentric neutral MV-90, Medium voltage underground distribution cable, 1 AWG EPR insulated primary UD cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e  0.89\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e  7\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 14 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e  80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 1.26\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e  887\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55210743103857,"sku":"NNC1193MEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_4daa3461-448b-48ba-abf5-3a9893ca6462.png?v=1763024703"},{"product_id":"1-0-awg-19-str-copper-primary-ud-cable-14-awg-1-3-neutral-epr-pvc-mv-90-100-260-mil-25-kv","title":"1\/0 AWG 19 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 260 mil 25 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_1__removed.pdf?v=1746173120\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1\/0 AWG 19 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 260 mil 25 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1\/0 AWG Copper EPR MV-90 cable, 1\/0 AWG PVC concentric neutral MV-90, Medium voltage underground distribution cable, 1\/0 AWG EPR insulated primary UD cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e  0.93\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e  9\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 14 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e  80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e  1.30\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e 1010\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55210745495921,"sku":"NNC01\/0MEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_4daa3461-448b-48ba-abf5-3a9893ca6462.png?v=1763024703"},{"product_id":"2-0-awg-19-str-copper-primary-ud-cable-14-awg-1-3-neutral-epr-pvc-mv-90-100-260-mil-25-kv","title":"2\/0 AWG 19 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 260 mil 25 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_1__removed.pdf?v=1746173120\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2\/0 AWG 19 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 260 mil 25 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e2\/0 AWG Copper EPR MV-90 cable, 2\/0 AWG PVC concentric neutral MV-90, Medium voltage underground distribution cable, 2\/0 AWG EPR insulated primary UD cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e   0.97\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e  11\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 14 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e  80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e  1.34\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e 1154\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55210746904945,"sku":"NNC02\/0MEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_4daa3461-448b-48ba-abf5-3a9893ca6462.png?v=1763024703"},{"product_id":"3-0-awg-19-str-copper-primary-ud-cable-14-awg-1-3-neutral-epr-pvc-mv-90-100-260-mil-25-kv","title":"3\/0 AWG 19 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 260 mil 25 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_1__removed.pdf?v=1746173120\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e3\/0 AWG 19 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 260 mil 25 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e3\/0 AWG Copper EPR MV-90 cable, 3\/0 AWG PVC concentric neutral MV-90, Medium voltage underground distribution cable, 3\/0 AWG EPR insulated primary UD cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 3\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.02\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e  14\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 14 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e  80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e  1.42\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e 1361\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55210748084593,"sku":"NNC03\/0MEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_4daa3461-448b-48ba-abf5-3a9893ca6462.png?v=1763024703"},{"product_id":"4-0-awg-19-str-copper-primary-ud-cable-14-awg-1-3-neutral-epr-pvc-mv-90-100-260-mil-25-kv","title":"4\/0 AWG 19 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 260 mil 25 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_1__removed.pdf?v=1746173120\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e4\/0 AWG 19 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 260 mil 25 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e4\/0 AWG Copper EPR MV-90 cable, 4\/0 AWG PVC concentric neutral MV-90, Medium voltage underground distribution cable, 4\/0 AWG EPR insulated primary UD cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 4\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.08\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 18\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 14 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e  80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e  1.47\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e 1591\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55210752115057,"sku":"NNC04\/0MEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_4daa3461-448b-48ba-abf5-3a9893ca6462.png?v=1763024703"},{"product_id":"250-mcm-37-str-copper-primary-ud-cable-12-awg-1-3-neutral-epr-pvc-mv-90-100-260-mil-25-kv","title":"250 MCM 37 Str Copper Primary UD Cable 12 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 260 mil 25 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_1__removed.pdf?v=1746173120\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e250 MCM 37 Str Copper Primary UD Cable 12 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 260 mil 25 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e250 MCM Copper EPR MV-90 cable, 250 MCM PVC concentric neutral MV-90, Medium voltage underground distribution cable, 250 MCM EPR insulated primary UD cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 250 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 37\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e  1.13\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 13\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 12 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e  80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e  1.56\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e 1792\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55210755490161,"sku":"NNC2501MEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_4daa3461-448b-48ba-abf5-3a9893ca6462.png?v=1763024703"},{"product_id":"350-mcm-37-str-copper-primary-ud-cable-12-awg-1-3-neutral-epr-pvc-mv-90-100-260-mil-25-kv","title":"350 MCM 37 Str Copper Primary UD Cable 12 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 260 mil 25 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_1__removed.pdf?v=1746173120\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e350 MCM 37 Str Copper Primary UD Cable 12 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 260 mil 25 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e350 MCM Copper EPR MV-90 cable, 350 MCM PVC concentric neutral MV-90, Medium voltage underground distribution cable, 350 MCM EPR insulated primary UD cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 350 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 37\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.24\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e  18\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 12 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e  80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e  1.66\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e 2282\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55210759094641,"sku":"NNC3501MEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_4daa3461-448b-48ba-abf5-3a9893ca6462.png?v=1763024703"},{"product_id":"500-mcm-37-str-copper-primary-ud-cable-10-awg-1-3-neutral-epr-pvc-mv-90-100-260-mil-25-kv","title":"500 MCM 37 Str Copper Primary UD Cable 10 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 260 mil 25 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_1__removed.pdf?v=1746173120\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e500 MCM 37 Str Copper Primary UD Cable 10 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 260 mil 25 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e500 MCM Copper EPR MV-90 cable, 500 MCM PVC concentric neutral MV-90, Medium voltage underground distribution cable, 500 MCM EPR insulated primary UD cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 500 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 37\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.37\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 17\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 10 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e  110\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e  1.90\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e  3154\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55210762797425,"sku":"NNC5001MEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_4daa3461-448b-48ba-abf5-3a9893ca6462.png?v=1763024703"},{"product_id":"750-mcm-61-str-copper-primary-ud-cable-9-awg-1-3-neutral-epr-pvc-mv-90-100-260-mil-25-kv","title":"750 MCM 61 Str Copper Primary UD Cable 9 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 260 mil 25 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_1__removed.pdf?v=1746173120\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e750 MCM 61 Str Copper Primary UD Cable 9 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 260 mil 25 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e750 MCM Copper EPR MV-90 cable, 750 MCM PVC concentric neutral MV-90, Medium voltage underground distribution cable, 750 MCM EPR insulated primary UD cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 750 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 61\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e  1.56\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 20\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 9 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e  110\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e  2.14\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e  4408\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55210767778161,"sku":"NNC7501MEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_4daa3461-448b-48ba-abf5-3a9893ca6462.png?v=1763024703"}],"url":"https:\/\/nassaunationalcable.com\/en-ca\/collections\/copper-epr-pvc-concentric-neutral-mv-90-primary-ud-cable-5-kv-46-kv.oembed?page=6","provider":"NassauNationalCable","version":"1.0","type":"link"}