{"title":"Aluminum EPR \/ PVC Concentric Neutral MV-90 Primary UD Cable 5 kV - 46 kV","description":"","products":[{"product_id":"2-awg-7-str-aluminum-primary-ud-cable-14-awg-1-3-neutral-epr-pvc-mv-90-100-175-mil-15-kv","title":"2 AWG 7 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_2__removed_1.pdf?v=1746525695\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2 AWG 7 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e2 AWG Aluminum MV-90 UD cable 15kV, EPR PVC concentric neutral cable 25kV, Primary UD cable 5kV to 46kV, 2 AWG Aluminum underground power cable MV-90, 15kV EPR PVC concentric UD cable, 2 AWG Medium voltage UD cable aluminum.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 7\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.67\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 6\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 14 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e  1.05\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e  503\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55212848087409,"sku":"NNC2EPR\/PVC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_d30ec62c-eef3-432f-802f-b2956a486780.png?v=1763024795"},{"product_id":"1-awg-19-str-aluminum-primary-ud-cable-14-awg-1-3-neutral-epr-pvc-mv-90-100-175-mil-15-kv","title":"1 AWG 19 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_2__removed_1.pdf?v=1746525695\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1 AWG 19 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1 AWG Aluminum MV-90 UD cable 15kV, EPR PVC concentric neutral cable 25kV, Primary UD cable 5kV to 46kV, 1 AWG Aluminum underground power cable MV-90, 15kV EPR PVC concentric UD cable, 1 AWG Medium voltage UD cable aluminum.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e  0.71\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 6\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 14 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.08\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 540\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55215606333809,"sku":"NNC1EPR\/PVC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_d30ec62c-eef3-432f-802f-b2956a486780.png?v=1763024795"},{"product_id":"1-0-awg-19-str-aluminum-primary-ud-cable-14-awg-1-3-neutral-epr-pvc-mv-90-100-175-mil-15-kv","title":"1\/0 AWG 19 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_2__removed_1.pdf?v=1746525695\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1\/0 AWG 19 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1\/0 AWG Aluminum MV-90 UD cable 15kV, EPR PVC concentric neutral cable 25kV, Primary UD cable 5kV to 46kV, 1\/0 AWG Aluminum underground power cable MV-90, 15kV EPR PVC concentric UD cable, 1\/0 AWG Medium voltage UD cable aluminum.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e   0.75\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 6\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 14 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e  1.12\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 582\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55215659090289,"sku":"NNC1\/0EPR\/PVC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_d30ec62c-eef3-432f-802f-b2956a486780.png?v=1763024795"},{"product_id":"2-0-awg-19-str-aluminum-primary-ud-cable-14-awg-1-3-neutral-epr-pvc-mv-90-100-175-mil-15-kv","title":"2\/0 AWG 19 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_2__removed_1.pdf?v=1746525695\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2\/0 AWG 19 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e2\/0 AWG Aluminum MV-90 UD cable 15kV, EPR PVC concentric neutral cable 25kV, Primary UD cable 5kV to 46kV, 2\/0 AWG Aluminum underground power cable MV-90, 15kV EPR PVC concentric UD cable, 2\/0 AWG Medium voltage UD cable aluminum.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e  0.80\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 7\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 14 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.17\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 647\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55215685042545,"sku":"NNC2\/0EPR\/PVC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_d30ec62c-eef3-432f-802f-b2956a486780.png?v=1763024795"},{"product_id":"3-0-awg-19-str-aluminum-primary-ud-cable-14-awg-1-3-neutral-epr-pvc-mv-90-100-175-mil-15-kv","title":"3\/0 AWG 19 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_2__removed_1.pdf?v=1746525695\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e3\/0 AWG 19 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e3\/0 AWG Aluminum MV-90 UD cable 15kV, EPR PVC concentric neutral cable 25kV, Primary UD cable 5kV to 46kV, 3\/0 AWG Aluminum underground power cable MV-90, 15kV EPR PVC concentric UD cable, 3\/0 AWG Medium voltage UD cable aluminum.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 3\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e  0.85\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 9\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 14 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e  1.22\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e  735\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55215711912305,"sku":"NNC3\/0EPR\/PVC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_d30ec62c-eef3-432f-802f-b2956a486780.png?v=1763024795"},{"product_id":"4-0-awg-19-str-aluminum-primary-ud-cable-14-awg-1-3-neutral-epr-pvc-mv-90-100-175-mil-15-kv","title":"4\/0 AWG 19 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_2__removed_1.pdf?v=1746525695\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e4\/0 AWG 19 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e4\/0 AWG Aluminum MV-90 UD cable 15kV, EPR PVC concentric neutral cable 25kV, Primary UD cable 5kV to 46kV, 4\/0 AWG Aluminum underground power cable MV-90, 15kV EPR PVC concentric UD cable, 4\/0 AWG Medium voltage UD cable aluminum.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 4\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e  0.90\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 11\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 14 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.27\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e  836\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55215744090481,"sku":"NNC4\/0EPR\/PVC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_d30ec62c-eef3-432f-802f-b2956a486780.png?v=1763024795"},{"product_id":"250-mcm-37-str-aluminum-primary-ud-cable-14-awg-1-3-neutral-epr-pvc-mv-90-100-175-mil-15-kv","title":"250 MCM 37 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_2__removed_1.pdf?v=1746525695\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e250 MCM 37 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e250 MCM Aluminum MV-90 UD cable 15kV, EPR PVC concentric neutral cable 25kV, Primary UD cable 5kV to 46kV, 250 MCM Aluminum underground power cable MV-90, 15kV EPR PVC concentric UD cable, 250 MCM Medium voltage UD cable aluminum.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 250 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 37\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e  0.96\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 13\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 14 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.33\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e  930\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55215771812209,"sku":"NNC250EPR\/PVC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_d30ec62c-eef3-432f-802f-b2956a486780.png?v=1763024795"},{"product_id":"350-mcm-37-str-aluminum-primary-ud-cable-14-awg-1-3-neutral-epr-pvc-mv-90-100-175-mil-15-kv","title":"350 MCM 37 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_2__removed_1.pdf?v=1746525695\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e350 MCM 37 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e350 MCM Aluminum MV-90 UD cable 15kV, EPR PVC concentric neutral cable 25kV, Primary UD cable 5kV to 46kV, 350 MCM Aluminum underground power cable MV-90, 15kV EPR PVC concentric UD cable, 350 MCM Medium voltage UD cable aluminum.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 350 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 37\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.06\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 18\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 14 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e  1.46\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 1174\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55215790391665,"sku":"NNC350EPR\/PVC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_d30ec62c-eef3-432f-802f-b2956a486780.png?v=1763024795"},{"product_id":"500-mcm-37-str-aluminum-primary-ud-cable-12-awg-1-3-neutral-epr-pvc-mv-90-100-175-mil-15-kv","title":"500 MCM 37 Str Aluminum Primary UD Cable 12 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_2__removed_1.pdf?v=1746525695\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e500 MCM 37 Str Aluminum Primary UD Cable 12 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e500 MCM Aluminum MV-90 UD cable 15kV, EPR PVC concentric neutral cable 25kV, Primary UD cable 5kV to 46kV, 500 MCM Aluminum underground power cable MV-90, 15kV EPR PVC concentric UD cable, 500 MCM Medium voltage UD cable aluminum.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 500 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 37\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.19\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 16\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 12 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.62\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e  1495\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55215809593713,"sku":"NNC500EPR\/PVC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_d30ec62c-eef3-432f-802f-b2956a486780.png?v=1763024795"},{"product_id":"750-mcm-61-str-aluminum-primary-ud-cable-10-awg-1-3-neutral-epr-pvc-mv-90-100-175-mil-15-kv","title":"750 MCM 61 Str Aluminum Primary UD Cable 10 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_2__removed_1.pdf?v=1746525695\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e750 MCM 61 Str Aluminum Primary UD Cable 10 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e750 MCM Aluminum MV-90 UD cable 15kV, EPR PVC concentric neutral cable 25kV, Primary UD cable 5kV to 46kV, 750 MCM Aluminum underground power cable MV-90, 15kV EPR PVC concentric UD cable, 750 MCM Medium voltage UD cable aluminum.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 750 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e  61\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.40\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 15\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 10 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 110\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.93\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e  2153\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55215818310001,"sku":"NNC750EPR\/PVC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_d30ec62c-eef3-432f-802f-b2956a486780.png?v=1763024795"},{"product_id":"1000-mcm-61-str-aluminum-primary-ud-cable-9-awg-1-3-neutral-epr-pvc-mv-90-100-175-mil-15-kv","title":"1000 MCM 61 Str Aluminum Primary UD Cable 9 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_2__removed_1.pdf?v=1746525695\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1000 MCM 61 Str Aluminum Primary UD Cable 9 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1000 MCM Aluminum MV-90 UD cable 15kV, EPR PVC concentric neutral cable 25kV, Primary UD cable 5kV to 46kV, 1000 MCM Aluminum underground power cable MV-90, 15kV EPR PVC concentric UD cable, 1000 MCM Medium voltage UD cable aluminum.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1000 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e  61\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.54\u003cbr\u003e\u003cstrong\u003e• Number of Wires: \u003c\/strong\u003e16\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 9 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 110\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e  2.13\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e  2715\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55215835808113,"sku":"NNC1000EPR\/PVC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_d30ec62c-eef3-432f-802f-b2956a486780.png?v=1763024795"},{"product_id":"2-awg-7-str-aluminum-primary-ud-cable-14-awg-full-neutral-epr-pvc-mv-90-100-175-mil-15-kv","title":"2 AWG 7 Str Aluminum Primary UD Cable 14 AWG Full Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_2__removed_1.pdf?v=1746525695\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2 AWG 7 Str Aluminum Primary UD Cable 14 AWG Full Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e2 AWG Aluminum MV-90 UD cable 15kV, EPR PVC concentric neutral cable 25kV, Primary UD cable 5kV to 46kV, 2 AWG Aluminum underground power cable MV-90, 15kV EPR PVC concentric UD cable, 2 AWG Medium voltage UD cable aluminum.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e  7\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.67\u003cbr\u003e\u003cstrong\u003e• Number of Wires: \u003c\/strong\u003e10\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 14 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e  80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e  1.05\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e  556\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55215853109617,"sku":"NNC02EPR\/PVC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_d30ec62c-eef3-432f-802f-b2956a486780.png?v=1763024795"},{"product_id":"1-awg-19-str-aluminum-primary-ud-cable-14-awg-full-neutral-epr-pvc-mv-90-100-175-mil-15-kv","title":"1 AWG 19 Str Aluminum Primary UD Cable 14 AWG Full Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_2__removed_1.pdf?v=1746525695\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1 AWG 19 Str Aluminum Primary UD Cable 14 AWG Full Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1 AWG Aluminum MV-90 UD cable 15kV, EPR PVC concentric neutral cable 25kV, Primary UD cable 5kV to 46kV, 1 AWG Aluminum underground power cable MV-90, 15kV EPR PVC concentric UD cable, 1 AWG Medium voltage UD cable aluminum.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.71\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 13\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 14 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e  80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.08\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 633\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55215866741105,"sku":"NNC19EPR\/PVC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_d30ec62c-eef3-432f-802f-b2956a486780.png?v=1763024795"},{"product_id":"1-0-awg-19-str-aluminum-primary-ud-cable-14-awg-full-neutral-epr-pvc-mv-90-100-175-mil-15-kv","title":"1\/0 AWG 19 Str Aluminum Primary UD Cable 14 AWG Full Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_2__removed_1.pdf?v=1746525695\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1\/0 AWG 19 Str Aluminum Primary UD Cable 14 AWG Full Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1\/0 AWG Aluminum MV-90 UD cable 15kV, EPR PVC concentric neutral cable 25kV, Primary UD cable 5kV to 46kV, 1\/0 AWG Aluminum underground power cable MV-90, 15kV EPR PVC concentric UD cable, 1\/0 AWG Medium voltage UD cable aluminum.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.75\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e  16\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 14 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e  80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.12\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e  716\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55215884304753,"sku":"NNC01\/0EPR\/PVC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_d30ec62c-eef3-432f-802f-b2956a486780.png?v=1763024795"},{"product_id":"2-0-awg-19-str-aluminum-primary-ud-cable-12-awg-full-neutral-epr-pvc-mv-90-100-175-mil-15-kv","title":"2\/0 AWG 19 Str Aluminum Primary UD Cable 12 AWG Full Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_2__removed_1.pdf?v=1746525695\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2\/0 AWG 19 Str Aluminum Primary UD Cable 12 AWG Full Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e2\/0 AWG Aluminum MV-90 UD cable 15kV, EPR PVC concentric neutral cable 25kV, Primary UD cable 5kV to 46kV, 2\/0 AWG Aluminum underground power cable MV-90, 15kV EPR PVC concentric UD cable, 2\/0 AWG Medium voltage UD cable aluminum.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.80\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 13\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 12 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e  80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e  1.20\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 835\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55215894987121,"sku":"NNC02\/0EPR\/PVC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_d30ec62c-eef3-432f-802f-b2956a486780.png?v=1763024795"},{"product_id":"3-0-awg-19-str-aluminum-primary-ud-cable-12-awg-full-neutral-epr-pvc-mv-90-100-175-mil-15-kv","title":"3\/0 AWG 19 Str Aluminum Primary UD Cable 12 AWG Full Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_2__removed_1.pdf?v=1746525695\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e3\/0 AWG 19 Str Aluminum Primary UD Cable 12 AWG Full Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e3\/0 AWG Aluminum MV-90 UD cable 15kV, EPR PVC concentric neutral cable 25kV, Primary UD cable 5kV to 46kV, 3\/0 AWG Aluminum underground power cable MV-90, 15kV EPR PVC concentric UD cable, 3\/0 AWG Medium voltage UD cable aluminum.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 3\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.85\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e  16\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 12 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e  80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.25\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e  960\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55215922905457,"sku":"NNC03\/0EPR\/PVC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_d30ec62c-eef3-432f-802f-b2956a486780.png?v=1763024795"},{"product_id":"4-0-awg-19-str-aluminum-primary-ud-cable-10-awg-full-neutral-epr-pvc-mv-90-100-175-mil-15-kv","title":"4\/0 AWG 19 Str Aluminum Primary UD Cable 10 AWG Full Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_2__removed_1.pdf?v=1746525695\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e4\/0 AWG 19 Str Aluminum Primary UD Cable 10 AWG Full Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e4\/0 AWG Aluminum MV-90 UD cable 15kV, EPR PVC concentric neutral cable 25kV, Primary UD cable 5kV to 46kV, 4\/0 AWG Aluminum underground power cable MV-90, 15kV EPR PVC concentric UD cable, 4\/0 AWG Medium voltage UD cable aluminum.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 4\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.90\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 13\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 10 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e  80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.35\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 1141\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55215923855729,"sku":"NNC04\/0EPR\/PVC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_d30ec62c-eef3-432f-802f-b2956a486780.png?v=1763024795"},{"product_id":"250-mcm-37-str-aluminum-primary-ud-cable-10-awg-full-neutral-epr-pvc-mv-90-100-175-mil-15-kv","title":"250 MCM 37 Str Aluminum Primary UD Cable 10 AWG Full Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_2__removed_1.pdf?v=1746525695\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e250 MCM 37 Str Aluminum Primary UD Cable 10 AWG Full Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e250 MCM Aluminum MV-90 UD cable 15kV, EPR PVC concentric neutral cable 25kV, Primary UD cable 5kV to 46kV, 250 MCM Aluminum underground power cable MV-90, 15kV EPR PVC concentric UD cable, 250 MCM Medium voltage UD cable aluminum.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 250 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 37\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e  0.96\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 16\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 10 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e  80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e  1.41\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 1309\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55215928770929,"sku":"NNC0250EPR\/PVC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_d30ec62c-eef3-432f-802f-b2956a486780.png?v=1763024795"},{"product_id":"350-mcm-37-str-aluminum-primary-ud-cable-9-awg-full-neutral-epr-pvc-mv-90-100-175-mil-15-kv","title":"350 MCM 37 Str Aluminum Primary UD Cable 9 AWG Full Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_2__removed_1.pdf?v=1746525695\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e350 MCM 37 Str Aluminum Primary UD Cable 9 AWG Full Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e350 MCM Aluminum MV-90 UD cable 15kV, EPR PVC concentric neutral cable 25kV, Primary UD cable 5kV to 46kV, 350 MCM Aluminum underground power cable MV-90, 15kV EPR PVC concentric UD cable, 350 MCM Medium voltage UD cable aluminum.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 350 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 37\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.06\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 16\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 9 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e  80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.56\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 1631\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55215929819505,"sku":"NNC0350EPR\/PVC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_d30ec62c-eef3-432f-802f-b2956a486780.png?v=1763024795"},{"product_id":"500-mcm-37-str-aluminum-primary-ud-cable-10-awg-full-neutral-epr-pvc-mv-90-100-175-mil-15-kv","title":"500 MCM 37 Str Aluminum Primary UD Cable 10 AWG Full Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_2__removed_1.pdf?v=1746525695\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e500 MCM 37 Str Aluminum Primary UD Cable 10 AWG Full Neutral EPR \/ PVC MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e500 MCM Aluminum MV-90 UD cable 15kV, EPR PVC concentric neutral cable 25kV, Primary UD cable 5kV to 46kV, 500 MCM Aluminum underground power cable MV-90, 15kV EPR PVC concentric UD cable, 500 MCM Medium voltage UD cable aluminum.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 500 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 37\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.19\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 29\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 10 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e  80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.66\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 2142\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55215930933617,"sku":"NNC0500EPR\/PVC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_d30ec62c-eef3-432f-802f-b2956a486780.png?v=1763024795"},{"product_id":"2-awg-7-str-aluminum-primary-ud-cable-14-awg-1-3-neutral-epr-pvc-mv-90-133-220-mil-15-kv","title":"2 AWG 7 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_2__removed_1.pdf?v=1746525695\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2 AWG 7 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e2 AWG Aluminum MV-90 UD cable 15kV, EPR PVC concentric neutral cable 25kV, Primary UD cable 5kV to 46kV, 2 AWG Aluminum underground power cable MV-90, 15kV EPR PVC concentric UD cable, 2 AWG Medium voltage UD cable aluminum.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 7\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.76\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e  6\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 14 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e  80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e  1.14\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 577\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55215957705073,"sku":"NNC21EPR\/PVC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_d30ec62c-eef3-432f-802f-b2956a486780.png?v=1763024795"},{"product_id":"1-awg-19-str-aluminum-primary-ud-cable-14-awg-1-3-neutral-epr-pvc-mv-90-133-220-mil-15-kv","title":"1 AWG 19 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_2__removed_1.pdf?v=1746525695\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1 AWG 19 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1 AWG Aluminum MV-90 UD cable 15kV, EPR PVC concentric neutral cable 25kV, Primary UD cable 5kV to 46kV, 1 AWG Aluminum underground power cable MV-90, 15kV EPR PVC concentric UD cable, 1 AWG Medium voltage UD cable aluminum.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e  0.80\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e  6\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 14 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e  80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.18\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e  617\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55215961047409,"sku":"NNC11EPR\/PVC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_d30ec62c-eef3-432f-802f-b2956a486780.png?v=1763024795"},{"product_id":"1-0-awg-19-str-aluminum-primary-ud-cable-14-awg-1-3-neutral-epr-pvc-mv-90-133-220-mil-15-kv","title":"1\/0 AWG 19 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_2__removed_1.pdf?v=1746525695\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1\/0 AWG 19 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1\/0 AWG Aluminum MV-90 UD cable 15kV, EPR PVC concentric neutral cable 25kV, Primary UD cable 5kV to 46kV, 1\/0 AWG Aluminum underground power cable MV-90, 15kV EPR PVC concentric UD cable, 1\/0 AWG Medium voltage UD cable aluminum.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e   0.84\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e  6\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 14 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e  80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e  1.22\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e  663\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55215964651889,"sku":"NNC1\/01EPR\/PVC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_d30ec62c-eef3-432f-802f-b2956a486780.png?v=1763024795"},{"product_id":"2-0-awg-19-str-aluminum-primary-ud-cable-14-awg-1-3-neutral-epr-pvc-mv-90-133-220-mil-15-kv","title":"2\/0 AWG 19 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_2__removed_1.pdf?v=1746525695\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2\/0 AWG 19 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e2\/0 AWG Aluminum MV-90 UD cable 15kV, EPR PVC concentric neutral cable 25kV, Primary UD cable 5kV to 46kV, 2\/0 AWG Aluminum underground power cable MV-90, 15kV EPR PVC concentric UD cable, 2\/0 AWG Medium voltage UD cable aluminum.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.89\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e  7\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 14 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e  80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e  1.26\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 731\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55215966421361,"sku":"NNC2\/01EPR\/PVC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_d30ec62c-eef3-432f-802f-b2956a486780.png?v=1763024795"},{"product_id":"3-0-awg-19-str-aluminum-primary-ud-cable-14-awg-1-3-neutral-epr-pvc-mv-90-133-220-mil-15-kv","title":"3\/0 AWG 19 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_2__removed_1.pdf?v=1746525695\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e3\/0 AWG 19 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e3\/0 AWG Aluminum MV-90 UD cable 15kV, EPR PVC concentric neutral cable 25kV, Primary UD cable 5kV to 46kV, 3\/0 AWG Aluminum underground power cable MV-90, 15kV EPR PVC concentric UD cable, 3\/0 AWG Medium voltage UD cable aluminum.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 3\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e  0.94\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e  9\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 14 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e  80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.31\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 823\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55215968944497,"sku":"NNC3\/01EPR\/PVC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_d30ec62c-eef3-432f-802f-b2956a486780.png?v=1763024795"},{"product_id":"4-0-awg-19-str-aluminum-primary-ud-cable-14-awg-1-3-neutral-epr-pvc-mv-90-133-220-mil-15-kv","title":"4\/0 AWG 19 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_2__removed_1.pdf?v=1746525695\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e4\/0 AWG 19 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e4\/0 AWG Aluminum MV-90 UD cable 15kV, EPR PVC concentric neutral cable 25kV, Primary UD cable 5kV to 46kV, 4\/0 AWG Aluminum underground power cable MV-90, 15kV EPR PVC concentric UD cable, 4\/0 AWG Medium voltage UD cable aluminum.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 4\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e  0.99\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 11\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 14 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e  80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e  1.37\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e  928\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55215971598705,"sku":"NNC4\/01EPR\/PVC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_d30ec62c-eef3-432f-802f-b2956a486780.png?v=1763024795"},{"product_id":"250-mcm-37-str-aluminum-primary-ud-cable-14-awg-1-3-neutral-epr-pvc-mv-90-133-220-mil-15-kv","title":"250 MCM 37 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_2__removed_1.pdf?v=1746525695\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e250 MCM 37 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e250 MCM Aluminum MV-90 UD cable 15kV, EPR PVC concentric neutral cable 25kV, Primary UD cable 5kV to 46kV, 250 MCM Aluminum underground power cable MV-90, 15kV EPR PVC concentric UD cable, 250 MCM Medium voltage UD cable aluminum.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 250 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 37\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e  1.05\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 13\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 14 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e  80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.44\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 1050\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55215979135345,"sku":"NNC2501EPR\/PVC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_d30ec62c-eef3-432f-802f-b2956a486780.png?v=1763024795"},{"product_id":"350-mcm-37-str-aluminum-primary-ud-cable-14-awg-1-3-neutral-epr-pvc-mv-90-133-220-mil-15-kv","title":"350 MCM 37 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_2__removed_1.pdf?v=1746525695\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e350 MCM 37 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e350 MCM Aluminum MV-90 UD cable 15kV, EPR PVC concentric neutral cable 25kV, Primary UD cable 5kV to 46kV, 350 MCM Aluminum underground power cable MV-90, 15kV EPR PVC concentric UD cable, 350 MCM Medium voltage UD cable aluminum.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 350 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 37\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e   1.15\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 18\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 14 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e  80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.55\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 1279\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55215980249457,"sku":"NNC3501EPR\/PVC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_d30ec62c-eef3-432f-802f-b2956a486780.png?v=1763024795"},{"product_id":"500-mcm-37-str-aluminum-primary-ud-cable-12-awg-1-3-neutral-epr-pvc-mv-90-133-220-mil-15-kv","title":"500 MCM 37 Str Aluminum Primary UD Cable 12 AWG 1\/3 Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_2__removed_1.pdf?v=1746525695\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e500 MCM 37 Str Aluminum Primary UD Cable 12 AWG 1\/3 Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e500 MCM Aluminum MV-90 UD cable 15kV, EPR PVC concentric neutral cable 25kV, Primary UD cable 5kV to 46kV, 500 MCM Aluminum underground power cable MV-90, 15kV EPR PVC concentric UD cable, 500 MCM Medium voltage UD cable aluminum.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 500 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 37\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e  1.28\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e  16\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 12 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 110\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e  1.77\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 1718\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55215981789553,"sku":"NNC5001EPR\/PVC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_d30ec62c-eef3-432f-802f-b2956a486780.png?v=1763024795"},{"product_id":"750-mcm-61-str-aluminum-primary-ud-cable-10-awg-1-3-neutral-epr-pvc-mv-90-133-220-mil-15-kv","title":"750 MCM 61 Str Aluminum Primary UD Cable 10 AWG 1\/3 Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_2__removed_1.pdf?v=1746525695\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e750 MCM 61 Str Aluminum Primary UD Cable 10 AWG 1\/3 Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e750 MCM Aluminum MV-90 UD cable 15kV, EPR PVC concentric neutral cable 25kV, Primary UD cable 5kV to 46kV, 750 MCM Aluminum underground power cable MV-90, 15kV EPR PVC concentric UD cable, 750 MCM Medium voltage UD cable aluminum.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 750 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e  61\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.49\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e  15\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 10 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 110\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 2.02\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e  2289\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55215984247153,"sku":"NNC7501EPR\/PVC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_d30ec62c-eef3-432f-802f-b2956a486780.png?v=1763024795"},{"product_id":"1000-mcm-61-str-aluminum-primary-ud-cable-9-awg-1-3-neutral-epr-pvc-mv-90-133-220-mil-15-kv","title":"1000 MCM 61 Str Aluminum Primary UD Cable 9 AWG 1\/3 Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_2__removed_1.pdf?v=1746525695\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1000 MCM 61 Str Aluminum Primary UD Cable 9 AWG 1\/3 Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1000 MCM Aluminum MV-90 UD cable 15kV, EPR PVC concentric neutral cable 25kV, Primary UD cable 5kV to 46kV, 1000 MCM Aluminum underground power cable MV-90, 15kV EPR PVC concentric UD cable, 1000 MCM Medium voltage UD cable aluminum.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1000 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e  61\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e  1.64\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e  16\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 9 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 110\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 2.23\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e  2864\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55215985492337,"sku":"NNC10001EPR\/PVC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_d30ec62c-eef3-432f-802f-b2956a486780.png?v=1763024795"},{"product_id":"2-awg-7-str-aluminum-primary-ud-cable-14-awg-full-neutral-epr-pvc-mv-90-133-220-mil-15-kv","title":"2 AWG 7 Str Aluminum Primary UD Cable 14 AWG Full Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_2__removed_1.pdf?v=1746525695\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2 AWG 7 Str Aluminum Primary UD Cable 14 AWG Full Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e2 AWG Aluminum MV-90 UD cable 15kV, EPR PVC concentric neutral cable 25kV, Primary UD cable 5kV to 46kV, 2 AWG Aluminum underground power cable MV-90, 15kV EPR PVC concentric UD cable, 2 AWG Medium voltage UD cable aluminum.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e  7\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e  0.76\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 10\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 14 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.14\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e  631\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55215988801905,"sku":"NNC27EPR\/PVC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_d30ec62c-eef3-432f-802f-b2956a486780.png?v=1763024795"},{"product_id":"1-awg-19-str-aluminum-primary-ud-cable-14-awg-full-neutral-epr-pvc-mv-90-133-220-mil-15-kv","title":"1 AWG 19 Str Aluminum Primary UD Cable 14 AWG Full Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_2__removed_1.pdf?v=1746525695\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1 AWG 19 Str Aluminum Primary UD Cable 14 AWG Full Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1 AWG Aluminum MV-90 UD cable 15kV, EPR PVC concentric neutral cable 25kV, Primary UD cable 5kV to 46kV, 1 AWG Aluminum underground power cable MV-90, 15kV EPR PVC concentric UD cable, 1 AWG Medium voltage UD cable aluminum.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e  19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.80\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e  13\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 14 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.18\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e  711\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55216002531697,"sku":"NNC109EPR\/PVC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_d30ec62c-eef3-432f-802f-b2956a486780.png?v=1763024795"},{"product_id":"1-0-awg-19-str-aluminum-primary-ud-cable-14-awg-full-neutral-epr-pvc-mv-90-133-220-mil-15-kv","title":"1\/0 AWG 19 Str Aluminum Primary UD Cable 14 AWG Full Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_2__removed_1.pdf?v=1746525695\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1\/0 AWG 19 Str Aluminum Primary UD Cable 14 AWG Full Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1\/0 AWG Aluminum MV-90 UD cable 15kV, EPR PVC concentric neutral cable 25kV, Primary UD cable 5kV to 46kV, 1\/0 AWG Aluminum underground power cable MV-90, 15kV EPR PVC concentric UD cable, 1\/0 AWG Medium voltage UD cable aluminum.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e  19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e  0.84\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 16\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 14 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.22\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e  797\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55216008921457,"sku":"NNC1\/02EPR\/PVC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_d30ec62c-eef3-432f-802f-b2956a486780.png?v=1763024795"},{"product_id":"2-0-awg-19-str-aluminum-primary-ud-cable-12-awg-full-neutral-epr-pvc-mv-90-133-220-mil-15-kv","title":"2\/0 AWG 19 Str Aluminum Primary UD Cable 12 AWG Full Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_2__removed_1.pdf?v=1746525695\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2\/0 AWG 19 Str Aluminum Primary UD Cable 12 AWG Full Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e2\/0 AWG Aluminum MV-90 UD cable 15kV, EPR PVC concentric neutral cable 25kV, Primary UD cable 5kV to 46kV, 2\/0 AWG Aluminum underground power cable MV-90, 15kV EPR PVC concentric UD cable, 2\/0 AWG Medium voltage UD cable aluminum.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e  19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e   0.89\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e  13\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 12 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.29\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e  919\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55216010068337,"sku":"NNC2\/02EPR\/PVC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_d30ec62c-eef3-432f-802f-b2956a486780.png?v=1763024795"},{"product_id":"3-0-awg-19-str-aluminum-primary-ud-cable-12-awg-full-neutral-epr-pvc-mv-90-133-220-mil-15-kv","title":"3\/0 AWG 19 Str Aluminum Primary UD Cable 12 AWG Full Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_2__removed_1.pdf?v=1746525695\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e3\/0 AWG 19 Str Aluminum Primary UD Cable 12 AWG Full Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e3\/0 AWG Aluminum MV-90 UD cable 15kV, EPR PVC concentric neutral cable 25kV, Primary UD cable 5kV to 46kV, 3\/0 AWG Aluminum underground power cable MV-90, 15kV EPR PVC concentric UD cable, 3\/0 AWG Medium voltage UD cable aluminum.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 3\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e  19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e  0.94\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 16\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 12 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.34\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 1048\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55216012427633,"sku":"NNC3\/02EPR\/PVC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_d30ec62c-eef3-432f-802f-b2956a486780.png?v=1763024795"},{"product_id":"4-0-awg-19-str-aluminum-primary-ud-cable-10-awg-full-neutral-epr-pvc-mv-90-133-220-mil-15-kv","title":"4\/0 AWG 19 Str Aluminum Primary UD Cable 10 AWG Full Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_2__removed_1.pdf?v=1746525695\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e4\/0 AWG 19 Str Aluminum Primary UD Cable 10 AWG Full Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e4\/0 AWG Aluminum MV-90 UD cable 15kV, EPR PVC concentric neutral cable 25kV, Primary UD cable 5kV to 46kV, 4\/0 AWG Aluminum underground power cable MV-90, 15kV EPR PVC concentric UD cable, 4\/0 AWG Medium voltage UD cable aluminum.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 4\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e  19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e  0.99\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 13\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003c\/strong\u003e\u003cspan\u003e  10 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.44\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 1233\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55216013017457,"sku":"NNC4\/02EPR\/PVC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_d30ec62c-eef3-432f-802f-b2956a486780.png?v=1763024795"},{"product_id":"250-mcm-37-str-aluminum-primary-ud-cable-10-awg-full-neutral-epr-pvc-mv-90-133-220-mil-15-kv","title":"250 MCM 37 Str Aluminum Primary UD Cable 10 AWG Full Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_2__removed_1.pdf?v=1746525695\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e250 MCM 37 Str Aluminum Primary UD Cable 10 AWG Full Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e250 MCM Aluminum MV-90 UD cable 15kV, EPR PVC concentric neutral cable 25kV, Primary UD cable 5kV to 46kV, 250 MCM Aluminum underground power cable MV-90, 15kV EPR PVC concentric UD cable, 250 MCM Medium voltage UD cable aluminum.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 250 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e  37\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e  1.05\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 16\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003c\/strong\u003e\u003cspan\u003e  10 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e  1.52\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e  1430\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55216013246833,"sku":"NNC2502EPR\/PVC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_d30ec62c-eef3-432f-802f-b2956a486780.png?v=1763024795"},{"product_id":"350-mcm-37-str-aluminum-primary-ud-cable-9-awg-full-neutral-epr-pvc-mv-90-133-220-mil-15-kv","title":"350 MCM 37 Str Aluminum Primary UD Cable 9 AWG Full Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_2__removed_1.pdf?v=1746525695\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e350 MCM 37 Str Aluminum Primary UD Cable 9 AWG Full Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e350 MCM Aluminum MV-90 UD cable 15kV, EPR PVC concentric neutral cable 25kV, Primary UD cable 5kV to 46kV, 350 MCM Aluminum underground power cable MV-90, 15kV EPR PVC concentric UD cable, 350 MCM Medium voltage UD cable aluminum.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 350 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e  37\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e  1.15\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 16\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 9 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.65\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 1737\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55216017572209,"sku":"NNC3502EPR\/PVC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_d30ec62c-eef3-432f-802f-b2956a486780.png?v=1763024795"},{"product_id":"500-mcm-37-str-aluminum-primary-ud-cable-10-awg-full-neutral-epr-pvc-mv-90-133-220-mil-15-kv","title":"500 MCM 37 Str Aluminum Primary UD Cable 10 AWG Full Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_2__removed_1.pdf?v=1746525695\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e500 MCM 37 Str Aluminum Primary UD Cable 10 AWG Full Neutral EPR \/ PVC MV-90 133% 220 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e500 MCM Aluminum MV-90 UD cable 15kV, EPR PVC concentric neutral cable 25kV, Primary UD cable 5kV to 46kV, 500 MCM Aluminum underground power cable MV-90, 15kV EPR PVC concentric UD cable, 500 MCM Medium voltage UD cable aluminum.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 500 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e  37\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e  1.28\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 29\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 10 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 110\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e  1.81\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 2367\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55216021930353,"sku":"NNC5002EPR\/PVC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_d30ec62c-eef3-432f-802f-b2956a486780.png?v=1763024795"},{"product_id":"1-awg-19-str-aluminum-primary-ud-cable-14-awg-1-3-neutral-epr-pvc-mv-90-100-260-mil-25-kv","title":"1 AWG 19 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 260 mil 25 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_2__removed_1.pdf?v=1746525695\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1 AWG 19 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 260 mil 25 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1 AWG Aluminum MV-90 UD cable 15kV, EPR PVC concentric neutral cable 25kV, Primary UD cable 5kV to 46kV, 1 AWG Aluminum underground power cable MV-90, 15kV EPR PVC concentric UD cable, 1 AWG Medium voltage UD cable aluminum.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e  0.88\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 6\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 14 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e  80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.26\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 692\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55216028451185,"sku":"NNC193EPR\/PVC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_d30ec62c-eef3-432f-802f-b2956a486780.png?v=1763024795"},{"product_id":"1-0-awg-19-str-aluminum-primary-ud-cable-14-awg-1-3-neutral-epr-pvc-mv-90-100-260-mil-25-kv","title":"1\/0 AWG 19 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 260 mil 25 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_2__removed_1.pdf?v=1746525695\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1\/0 AWG 19 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 260 mil 25 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1\/0 AWG Aluminum MV-90 UD cable 15kV, EPR PVC concentric neutral cable 25kV, Primary UD cable 5kV to 46kV, 1\/0 AWG Aluminum underground power cable MV-90, 15kV EPR PVC concentric UD cable, 1\/0 AWG Medium voltage UD cable aluminum.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e  0.92\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 6\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 14 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e  80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e  1.30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 741\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55217833869681,"sku":"NNC1\/03EPR\/PVC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_d30ec62c-eef3-432f-802f-b2956a486780.png?v=1763024795"},{"product_id":"2-0-awg-19-str-aluminum-primary-ud-cable-14-awg-1-3-neutral-epr-pvc-mv-90-100-260-mil-25-kv","title":"2\/0 AWG 19 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 260 mil 25 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_2__removed_1.pdf?v=1746525695\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2\/0 AWG 19 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 260 mil 25 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e2\/0 AWG Aluminum MV-90 UD cable 15kV, EPR PVC concentric neutral cable 25kV, Primary UD cable 5kV to 46kV, 2\/0 AWG Aluminum underground power cable MV-90, 15kV EPR PVC concentric UD cable, 2\/0 AWG Medium voltage UD cable aluminum.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.97\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e  7\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 14 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e  80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.34\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 812\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55217852219761,"sku":"NNC2\/03EPR\/PVC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_d30ec62c-eef3-432f-802f-b2956a486780.png?v=1763024795"},{"product_id":"3-0-awg-19-str-aluminum-primary-ud-cable-14-awg-1-3-neutral-epr-pvc-mv-90-100-260-mil-25-kv","title":"3\/0 AWG 19 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 260 mil 25 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_2__removed_1.pdf?v=1746525695\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e3\/0 AWG 19 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 260 mil 25 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e3\/0 AWG Aluminum MV-90 UD cable 15kV, EPR PVC concentric neutral cable 25kV, Primary UD cable 5kV to 46kV, 3\/0 AWG Aluminum underground power cable MV-90, 15kV EPR PVC concentric UD cable, 3\/0 AWG Medium voltage UD cable aluminum.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 3\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.02\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e  9\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 14 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e  80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.41\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 930\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55217857724785,"sku":"NNC3\/03EPR\/PVC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_d30ec62c-eef3-432f-802f-b2956a486780.png?v=1763024795"},{"product_id":"4-0-awg-19-str-aluminum-primary-ud-cable-14-awg-1-3-neutral-epr-pvc-mv-90-100-260-mil-25-kv","title":"4\/0 AWG 19 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 260 mil 25 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_2__removed_1.pdf?v=1746525695\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e4\/0 AWG 19 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 260 mil 25 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e4\/0 AWG Aluminum MV-90 UD cable 15kV, EPR PVC concentric neutral cable 25kV, Primary UD cable 5kV to 46kV, 4\/0 AWG Aluminum underground power cable MV-90, 15kV EPR PVC concentric UD cable, 4\/0 AWG Medium voltage UD cable aluminum.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 4\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e  1.07\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 11\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 14 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e  80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.47\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 1040\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55217864245617,"sku":"NNC4\/03EPR\/PVC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_d30ec62c-eef3-432f-802f-b2956a486780.png?v=1763024795"},{"product_id":"250-mcm-37-str-aluminum-primary-ud-cable-14-awg-1-3-neutral-epr-pvc-mv-90-100-260-mil-25-kv","title":"250 MCM 37 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 260 mil 25 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_2__removed_1.pdf?v=1746525695\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e250 MCM 37 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 260 mil 25 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e250 MCM Aluminum MV-90 UD cable 15kV, EPR PVC concentric neutral cable 25kV, Primary UD cable 5kV to 46kV, 250 MCM Aluminum underground power cable MV-90, 15kV EPR PVC concentric UD cable, 250 MCM Medium voltage UD cable aluminum.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 250 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 37\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e  1.13\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e  13\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 14 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e  80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e  1.53\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e  1143\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55217867194737,"sku":"NNC2503EPR\/PVC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_d30ec62c-eef3-432f-802f-b2956a486780.png?v=1763024795"},{"product_id":"350-mcm-37-str-aluminum-primary-ud-cable-14-awg-1-3-neutral-epr-pvc-mv-90-100-260-mil-25-kv","title":"350 MCM 37 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 260 mil 25 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_2__removed_1.pdf?v=1746525695\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e350 MCM 37 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 260 mil 25 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e350 MCM Aluminum MV-90 UD cable 15kV, EPR PVC concentric neutral cable 25kV, Primary UD cable 5kV to 46kV, 350 MCM Aluminum underground power cable MV-90, 15kV EPR PVC concentric UD cable, 350 MCM Medium voltage UD cable aluminum.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 350 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 37\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e  1.23\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 18\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 14 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e  80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.63\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 1379\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55217897177457,"sku":"NNC3503EPR\/PVC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_d30ec62c-eef3-432f-802f-b2956a486780.png?v=1763024795"},{"product_id":"500-mcm-37-str-aluminum-primary-ud-cable-12-awg-1-3-neutral-epr-pvc-mv-90-100-260-mil-25-kv","title":"500 MCM 37 Str Aluminum Primary UD Cable 12 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 260 mil 25 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_2__removed_1.pdf?v=1746525695\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e500 MCM 37 Str Aluminum Primary UD Cable 12 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 260 mil 25 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e500 MCM Aluminum MV-90 UD cable 15kV, EPR PVC concentric neutral cable 25kV, Primary UD cable 5kV to 46kV, 500 MCM Aluminum underground power cable MV-90, 15kV EPR PVC concentric UD cable, 500 MCM Medium voltage UD cable aluminum.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 500 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 37\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e  1.36\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 16\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 12 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 110\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.85\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 1831\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55217921130865,"sku":"NNC5003EPR\/PVC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_d30ec62c-eef3-432f-802f-b2956a486780.png?v=1763024795"},{"product_id":"750-mcm-61-str-aluminum-primary-ud-cable-10-awg-1-3-neutral-epr-pvc-mv-90-100-260-mil-25-kv","title":"750 MCM 61 Str Aluminum Primary UD Cable 10 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 260 mil 25 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_2__removed_1.pdf?v=1746525695\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e750 MCM 61 Str Aluminum Primary UD Cable 10 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 260 mil 25 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e750 MCM Aluminum MV-90 UD cable 15kV, EPR PVC concentric neutral cable 25kV, Primary UD cable 5kV to 46kV, 750 MCM Aluminum underground power cable MV-90, 15kV EPR PVC concentric UD cable, 750 MCM Medium voltage UD cable aluminum.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 750 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e  61\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.57\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 15\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 10 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 110\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e  2.13\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 2464\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55217935253873,"sku":"NNC7503EPR\/PVC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_d30ec62c-eef3-432f-802f-b2956a486780.png?v=1763024795"},{"product_id":"1000-mcm-61-str-aluminum-primary-ud-cable-9-awg-1-3-neutral-epr-pvc-mv-90-100-260-mil-25-kv","title":"1000 MCM 61 Str Aluminum Primary UD Cable 9 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 260 mil 25 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-05-epr-pvc_2__removed_1.pdf?v=1746525695\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1000 MCM 61 Str Aluminum Primary UD Cable 9 AWG 1\/3 Neutral EPR \/ PVC MV-90 100% 260 mil 25 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1000 MCM Aluminum MV-90 UD cable 15kV, EPR PVC concentric neutral cable 25kV, Primary UD cable 5kV to 46kV, 1000 MCM Aluminum underground power cable MV-90, 15kV EPR PVC concentric UD cable, 1000 MCM Medium voltage UD cable aluminum.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649: \u003c\/strong\u003eStandard for Concentric Neutral Rated Cables 5 kV – 46 kV\u003cbr\u003e\u003cstrong\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 kV – 46 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e• 5 kV – 46 kV, 100 and 133% IL\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003etemperatures:\u003c\/strong\u003e\u003cbr\u003eWet and dry locations\u003cbr\u003e• Normal: 105 °C\u003cbr\u003e• Emergency: 140 °C\u003cbr\u003e• Short Circuit: 250 °C\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request, larger sizes.\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Binder Tape:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA suitable polyester tape, as required.\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eExtruded Overlying (Sleeve) Black polyvinyl chloride (PVC) sunlight resistant.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1000 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e  61\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e  1.72\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 16\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003c\/strong\u003e\u003cspan\u003e 9 \u003c\/span\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 110\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e  2.31\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 3003\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55217937842545,"sku":"NNC10002EPR\/PVC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_d30ec62c-eef3-432f-802f-b2956a486780.png?v=1763024795"}],"url":"https:\/\/nassaunationalcable.com\/en-ca\/collections\/aluminum-epr-pvc-concentric-neutral-mv-90-primary-ud-cable-5-kv-46-kv.oembed?page=7","provider":"NassauNationalCable","version":"1.0","type":"link"}