{"title":"Aluminum EPR \/ LLDPE Concentric Neutral MV-90 Primary UD Cable 5 kV - 46 kV","description":"","products":[{"product_id":"2-awg-solid-aluminum-primary-ud-cable-14-awg-1-3-neutral-epr-lldpe-mv-90-100-175-mil-15-kv","title":"2 AWG Solid Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_2.pdf?v=1743233112\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2 AWG Solid Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e2 AWG Aluminum EPR cable, 2 AWG High voltage underground cable,5 kV to 46 kV aluminum cable,EPR insulated MV-90 cable,2 AWG EPR LLDPE cable, 2 AWG MV-90 primary UD 46 kV cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 1\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.65\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 6\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e14 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e50\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 0.95\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 441\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52216508711281,"sku":"NNC2LLDPE","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-29T171334.898.png?v=1763023724"},{"product_id":"2-awg-7-str-aluminum-primary-ud-cable-14-awg-1-3-neutral-epr-lldpe-mv-90-100-175-mil-15-kv","title":"2 AWG 7 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_2.pdf?v=1743233112\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2 AWG 7 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e2 AWG Aluminum EPR cable, 2 AWG High voltage underground cable,5 kV to 46 kV aluminum cable,EPR insulated MV-90 cable,2 AWG EPR LLDPE cable, 2 AWG MV-90 primary UD 46 kV cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cspan\u003e.\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 7\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.67\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 6\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e14 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e50\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 0.98\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 459\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52216528535921,"sku":"NNC02LLDPE","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-29T171334.898.png?v=1763023724"},{"product_id":"1-awg-19-str-aluminum-primary-ud-cable-14-awg-1-3-neutral-epr-lldpe-mv-90-100-175-mil-15-kv","title":"1 AWG 19 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_2.pdf?v=1743233112\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1 AWG 19 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1 AWG Aluminum EPR cable, 1 AWG High voltage underground cable,5 kV to 46 kV aluminum cable,EPR insulated MV-90 cable,1 AWG EPR LLDPE cable, 1 AWG MV-90 primary UD 46 kV cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19 \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.71\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 6\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e14 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e50\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.02\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 495\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52216573100401,"sku":"NNC1LLDPE","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-29T171334.898.png?v=1763023724"},{"product_id":"1-0-awg-solid-aluminum-primary-ud-cable-14-awg-1-3-neutral-epr-lldpe-mv-90-100-175-mil-15-kv","title":"1\/0 AWG Solid Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_2.pdf?v=1743233112\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1\/0 AWG Solid Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1\/0 AWG Aluminum EPR cable, 1\/0 AWG High voltage underground cable,5 kV to 46 kV aluminum cable,EPR insulated MV-90 cable,1\/0 AWG EPR LLDPE cable, 1\/0 AWG MV-90 primary UD 46 kV cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19 \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.72\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 6\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e14 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e50\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.02\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 512\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52216573591921,"sku":"NNC1\/0LLDPE","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-29T171334.898.png?v=1763023724"},{"product_id":"1-0-awg-19-str-aluminum-primary-ud-cable-14-awg-1-3-neutral-epr-lldpe-mv-90-100-175-mil-15-kv","title":"1\/0 AWG 19 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_2.pdf?v=1743233112\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1\/0 AWG 19 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1\/0 AWG Aluminum EPR cable, 1\/0 AWG High voltage underground cable,5 kV to 46 kV aluminum cable,EPR insulated MV-90 cable,1\/0 AWG EPR LLDPE cable, 1\/0 AWG MV-90 primary UD 46 kV cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003c\/strong\u003e Hard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19 \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.75\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 6\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e14 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e50\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.06\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 537\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52216582570353,"sku":"NNC01\/0LLDPE","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-29T171334.898.png?v=1763023724"},{"product_id":"2-0-awg-19-str-aluminum-primary-ud-cable-14-awg-1-3-neutral-epr-lldpe-mv-90-100-175-mil-15-kv","title":"2\/0 AWG 19 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_2.pdf?v=1743233112\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2\/0 AWG 19 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e2\/0 AWG Aluminum EPR cable, 2\/0 AWG High voltage underground cable,5 kV to 46 kV aluminum cable,EPR insulated MV-90 cable, 2\/0 AWG EPR LLDPE cable, 2\/0 AWG MV-90 primary UD 46 kV cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003c\/strong\u003e Hard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19 \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.80\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 7\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e14 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e50\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.10\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 600\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52216584438129,"sku":"NNC2\/0LLDPE","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-29T171334.898.png?v=1763023724"},{"product_id":"3-0-awg-19-str-aluminum-primary-ud-cable-14-awg-1-3-neutral-epr-lldpe-mv-90-100-175-mil-15-kv","title":"3\/0 AWG 19 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_2.pdf?v=1743233112\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e3\/0 AWG 19 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e3\/0 AWG Aluminum EPR cable, 3\/0 AWG High voltage underground cable,5 kV to 46 kV aluminum cable,EPR insulated MV-90 cable, 3\/0 AWG EPR LLDPE cable, 3\/0 AWG MV-90 primary UD 46 kV cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003c\/strong\u003e Hard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 3\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19 \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.85\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 9\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e14 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e50\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.15\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 684\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52216586994033,"sku":"NNC3\/0LLDPE","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-29T171334.898.png?v=1763023724"},{"product_id":"4-0-awg-19-str-aluminum-primary-ud-cable-14-awg-1-3-neutral-epr-lldpe-mv-90-100-175-mil-15-kv","title":"4\/0 AWG 19 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_2.pdf?v=1743233112\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e4\/0 AWG 19 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e4\/0 AWG Aluminum EPR cable, 4\/0 AWG High voltage underground cable,5 kV to 46 kV aluminum cable,EPR insulated MV-90 cable, 4\/0 AWG EPR LLDPE cable, 4\/0 AWG MV-90 primary UD 46 kV cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 4\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19 \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.90\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 11 \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e14 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e50\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.21\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 781\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52216588861809,"sku":"NNC4\/0LLDPE","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-29T171334.898.png?v=1763023724"},{"product_id":"250-mcm-37-str-aluminum-primary-ud-cable-14-awg-1-3-neutral-epr-lldpe-mv-90-100-175-mil-15-kv","title":"250 MCM 37 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_2.pdf?v=1743233112\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e250 MCM 37 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e250 MCM Aluminum EPR cable, 250 MCM High voltage underground cable,5 kV to 46 kV aluminum cable,EPR insulated MV-90 cable, 250 MCM EPR LLDPE cable, 250 MCM  MV-90 primary UD 46 kV cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 250 MCM \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 37\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.96\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 13\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e14 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e50\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.26\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 871\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52216594596209,"sku":"NNC250LLDPE","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-29T171334.898.png?v=1763023724"},{"product_id":"300-mcm-37-str-aluminum-primary-ud-cable-14-awg-1-3-neutral-epr-lldpe-mv-90-100-175-mil-15-kv","title":"300 MCM 37 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_2.pdf?v=1743233112\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e300 MCM 37 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e300 MCM Aluminum EPR cable, 300 MCM High voltage underground cable,5 kV to 46 kV aluminum cable,EPR insulated MV-90 cable, 300 MCM EPR LLDPE cable, 300 MCM  MV-90 primary UD 46 kV cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 300 MCM \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 37\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.01 \u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 15\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e14 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e50\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.34\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 994\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52216595218801,"sku":"NNC300LLDPE","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-29T171334.898.png?v=1763023724"},{"product_id":"350-mcm-37-str-aluminum-primary-ud-cable-14-awg-1-3-neutral-epr-lldpe-mv-90-100-175-mil-15-kv","title":"350 MCM 37 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_2.pdf?v=1743233112\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e350 MCM 37 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e350 MCM Aluminum EPR cable, 350 MCM High voltage underground cable,5 kV to 46 kV aluminum cable,EPR insulated MV-90 cable, 350 MCM EPR LLDPE cable, 350 MCM  MV-90 primary UD 46 kV cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 350 MCM \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 37\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.06\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 18\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e14 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e50\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.39\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 1106\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52216596463985,"sku":"NNC350LLDPE","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-29T171334.898.png?v=1763023724"},{"product_id":"500-mcm-37-str-aluminum-primary-ud-cable-14-awg-1-3-neutral-epr-lldpe-mv-90-100-175-mil-15-kv","title":"500 MCM 37 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_2.pdf?v=1743233112\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e500 MCM 37 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e500 MCM Aluminum EPR cable, 500 MCM High voltage underground cable,5 kV to 46 kV aluminum cable,EPR insulated MV-90 cable, 500 MCM EPR LLDPE cable, 500 MCM  MV-90 primary UD 46 kV cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 500 MCM \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 37\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.19\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 25\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e14 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e50\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.52\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 1403\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52222258282865,"sku":"NNC500LLDPE","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-29T171334.898.png?v=1763023724"},{"product_id":"500-mcm-37-str-aluminum-primary-ud-cable-12-awg-1-3-neutral-epr-lldpe-mv-90-100-175-mil-15-kv","title":"500 MCM 37 Str Aluminum Primary UD Cable 12 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_2.pdf?v=1743233112\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e500 MCM 37 Str Aluminum Primary UD Cable 12 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e500 MCM Aluminum EPR cable, 500 MCM High voltage underground cable,5 kV to 46 kV aluminum cable,EPR insulated MV-90 cable, 500 MCM EPR LLDPE cable, 500 MCM  MV-90 primary UD 46 kV cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 500 MCM \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 37\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.19\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 16\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e12 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e50\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.55\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 1441\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52222265622897,"sku":"NNC0500LLDPE","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-29T171334.898.png?v=1763023724"},{"product_id":"750-mcm-61-str-aluminum-primary-ud-cable-12-awg-1-3-neutral-epr-lldpe-mv-90-100-175-mil-15-kv","title":"750 MCM 61 Str Aluminum Primary UD Cable 12 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_2.pdf?v=1743233112\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e750 MCM 61 Str Aluminum Primary UD Cable 12 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e750 MCM Aluminum EPR cable, 750 MCM High voltage underground cable,5 kV to 46 kV aluminum cable,EPR insulated MV-90 cable, 750 MCM EPR LLDPE cable, 750 MCM  MV-90 primary UD 46 kV cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 750 MCM \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 61\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.40\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 24\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e12 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.82\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 2033 \u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52222270931313,"sku":"NNC750LLDPE","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-29T171334.898.png?v=1763023724"},{"product_id":"750-mcm-61-str-aluminum-primary-ud-cable-10-awg-1-3-neutral-epr-lldpe-mv-90-100-175-mil-15-kv","title":"750 MCM 61 Str Aluminum Primary UD Cable 10 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_2.pdf?v=1743233112\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e750 MCM 61 Str Aluminum Primary UD Cable 10 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e750 MCM Aluminum EPR cable, 750 MCM High voltage underground cable,5 kV to 46 kV aluminum cable,EPR insulated MV-90 cable, 750 MCM EPR LLDPE cable, 750 MCM  MV-90 primary UD 46 kV cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 750 MCM \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 61\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.40\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 15\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e10 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.86\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 2079\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52222272864625,"sku":"NNC0750LLDPE","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-29T171334.898.png?v=1763023724"},{"product_id":"1000-mcm-61-str-aluminum-primary-ud-cable-12-awg-1-3-neutral-epr-lldpe-mv-90-100-175-mil-15-kv","title":"1000 MCM 61 Str Aluminum Primary UD Cable 12 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_2.pdf?v=1743233112\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1000 MCM 61 Str Aluminum Primary UD Cable 12 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1000 MCM Aluminum EPR cable, 1000 MCM High voltage underground cable,5 kV to 46 kV aluminum cable,EPR insulated MV-90 cable, 1000 MCM EPR LLDPE cable, 1000 MCM  MV-90 primary UD 46 kV cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1000 MCM \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 61\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.54\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 31\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e12 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 2.00\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 2544\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52222280368497,"sku":"NNC1000LLDPE","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-29T171334.898.png?v=1763023724"},{"product_id":"1000-mcm-61-str-aluminum-primary-ud-cable-10-awg-1-3-neutral-epr-lldpe-mv-90-100-175-mil-15-kv","title":"1000 MCM 61 Str Aluminum Primary UD Cable 10 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_2.pdf?v=1743233112\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1000 MCM 61 Str Aluminum Primary UD Cable 10 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1000 MCM Aluminum EPR cable, 1000 MCM High voltage underground cable,5 kV to 46 kV aluminum cable,EPR insulated MV-90 cable, 1000 MCM EPR LLDPE cable, 1000 MCM  MV-90 primary UD 46 kV cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1000 MCM \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 61\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.54\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 20\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e10 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 2.04\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 2614\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52222282039665,"sku":"NNC01000LLDPE","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-29T171334.898.png?v=1763023724"},{"product_id":"1000-mcm-61-str-aluminum-primary-ud-cable-9-awg-1-3-neutral-epr-lldpe-mv-90-100-175-mil-15-kv","title":"1000 MCM 61 Str Aluminum Primary UD Cable 9 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_2.pdf?v=1743233112\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1000 MCM 61 Str Aluminum Primary UD Cable 9 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1000 MCM Aluminum EPR cable, 1000 MCM High voltage underground cable,5 kV to 46 kV aluminum cable,EPR insulated MV-90 cable, 1000 MCM EPR LLDPE cable, 1000 MCM  MV-90 primary UD 46 kV cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1000 MCM \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 61\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.54\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 16\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e9 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 2.07 \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 2651\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52222294983025,"sku":"NNCU1000LLDPE","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-29T171334.898.png?v=1763023724"},{"product_id":"2-awg-solid-aluminum-primary-ud-cable-14-awg-full-neutral-epr-lldpe-mv-90-100-175-mil-15-kv","title":"2 AWG Solid Aluminum Primary UD Cable 14 AWG Full Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_2.pdf?v=1743233112\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2 AWG Solid Aluminum Primary UD Cable 14 AWG Full Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e2 AWG Aluminum EPR cable, 2 AWG High voltage underground cable,5 kV to 46 kV aluminum cable,EPR insulated MV-90 cable, 2 AWG EPR LLDPE cable, 2 AWG  MV-90 primary UD 46 kV cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 1 \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.65\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 10\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e14 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 50\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 0.95\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 489\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52222297538929,"sku":"NNCU2LLDPE","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-29T171334.898.png?v=1763023724"},{"product_id":"2-awg-7-str-aluminum-primary-ud-cable-14-awg-full-neutral-epr-lldpe-mv-90-100-175-mil-15-kv","title":"2 AWG 7 Str Aluminum Primary UD Cable 14 AWG Full Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_2.pdf?v=1743233112\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2 AWG 7 Str Aluminum Primary UD Cable 14 AWG Full Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e2 AWG Aluminum EPR cable, 2 AWG High voltage underground cable,5 kV to 46 kV aluminum cable,EPR insulated MV-90 cable, 2 AWG EPR LLDPE cable, 2 AWG  MV-90 primary UD 46 kV cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 7 \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.67\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 10\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e14 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 50\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 0.98\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 507\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52222306058609,"sku":"NNCU02LLDPE","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-29T171334.898.png?v=1763023724"},{"product_id":"1-awg-19-str-aluminum-primary-ud-cable-14-awg-full-neutral-epr-lldpe-mv-90-100-175-mil-15-kv","title":"1 AWG 19 Str Aluminum Primary UD Cable 14 AWG Full Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_2.pdf?v=1743233112\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1 AWG 19 Str Aluminum Primary UD Cable 14 AWG Full Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1 AWG Aluminum EPR cable, 1 AWG High voltage underground cable,5 kV to 46 kV aluminum cable,EPR insulated MV-90 cable, 1 AWG EPR LLDPE cable, 1 AWG MV-90 primary UD 46 kV cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.71 \u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 13\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e14 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 50\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.02\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 580\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52222307041649,"sku":"NNCU1LLDPE","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-29T171334.898.png?v=1763023724"},{"product_id":"1-0-awg-solid-aluminum-primary-ud-cable-14-awg-full-neutral-epr-lldpe-mv-90-100-175-mil-15-kv","title":"1\/0 AWG Solid Aluminum Primary UD Cable 14 AWG Full Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_2.pdf?v=1743233112\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1\/0 AWG Solid Aluminum Primary UD Cable 14 AWG Full Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1\/0 AWG Aluminum EPR cable, 1\/0 AWG High voltage underground cable,5 kV to 46 kV aluminum cable,EPR insulated MV-90 cable, 1\/0 AWG EPR LLDPE cable, 1\/0 AWG MV-90 primary UD 46 kV cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 1 \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.72\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 16\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e14 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 50\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.02\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 632\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52222309400945,"sku":"NNCU1\/0LLDPE","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-29T171334.898.png?v=1763023724"},{"product_id":"1-0-awg-19-str-aluminum-primary-ud-cable-14-awg-full-neutral-epr-lldpe-mv-90-100-175-mil-15-kv","title":"1\/0 AWG 19 Str Aluminum Primary UD Cable 14 AWG Full Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_2.pdf?v=1743233112\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1\/0 AWG 19 Str Aluminum Primary UD Cable 14 AWG Full Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1\/0 AWG Aluminum EPR cable, 1\/0 AWG High voltage underground cable,5 kV to 46 kV aluminum cable,EPR insulated MV-90 cable, 1\/0 AWG EPR LLDPE cable, 1\/0 AWG MV-90 primary UD 46 kV cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.75\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 16\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e14 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 50\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.06\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 658\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52222317691249,"sku":"NNCU01\/0LLDPE","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-29T171334.898.png?v=1763023724"},{"product_id":"2-0-awg-19-str-aluminum-primary-ud-cable-14-awg-full-neutral-epr-lldpe-mv-90-100-175-mil-15-kv","title":"2\/0 AWG 19 Str Aluminum Primary UD Cable 14 AWG Full Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_2.pdf?v=1743233112\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2\/0 AWG 19 Str Aluminum Primary UD Cable 14 AWG Full Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e2\/0 AWG Aluminum EPR cable, 2\/0 AWG High voltage underground cable,5 kV to 46 kV aluminum cable,EPR insulated MV-90 cable, 2\/0 AWG EPR LLDPE cable, 2\/0 AWG MV-90 primary UD 46 kV cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.80\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 20\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e14 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 50\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.10\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 757\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52222319329649,"sku":"NNCU2\/0LLDPE","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-29T171334.898.png?v=1763023724"},{"product_id":"2-0-awg-19-str-aluminum-primary-ud-cable-12-awg-full-neutral-epr-lldpe-mv-90-100-175-mil-15-kv","title":"2\/0 AWG 19 Str Aluminum Primary UD Cable 12 AWG Full Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_2.pdf?v=1743233112\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2\/0 AWG 19 Str Aluminum Primary UD Cable 12 AWG Full Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e2\/0 AWG Aluminum EPR cable, 2\/0 AWG High voltage underground cable,5 kV to 46 kV aluminum cable,EPR insulated MV-90 cable, 2\/0 AWG EPR LLDPE cable, 2\/0 AWG MV-90 primary UD 46 kV cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.80\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 13\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e12 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 50\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.13\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 788\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52222321033585,"sku":"NNCU02\/0LLDPE","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-29T171334.898.png?v=1763023724"},{"product_id":"3-0-awg-19-str-aluminum-primary-ud-cable-14-awg-full-neutral-epr-lldpe-mv-90-100-175-mil-15-kv","title":"3\/0 AWG 19 Str Aluminum Primary UD Cable 14 AWG Full Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_2.pdf?v=1743233112\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e3\/0 AWG 19 Str Aluminum Primary UD Cable 14 AWG Full Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e3\/0 AWG Aluminum EPR cable, 3\/0 AWG High voltage underground cable,5 kV to 46 kV aluminum cable,EPR insulated MV-90 cable, 3\/0 AWG EPR LLDPE cable, 3\/0 AWG MV-90 primary UD 46 kV cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 3\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.85\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 25\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e14 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 50\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.15\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 877\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52222323360113,"sku":"NNCU3\/0LLDPE","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-29T171334.898.png?v=1763023724"},{"product_id":"3-0-awg-19-str-aluminum-primary-ud-cable-12-awg-full-neutral-epr-lldpe-mv-90-100-175-mil-15-kv","title":"3\/0 AWG 19 Str Aluminum Primary UD Cable 12 AWG Full Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_2.pdf?v=1743233112\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e3\/0 AWG 19 Str Aluminum Primary UD Cable 12 AWG Full Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e3\/0 AWG Aluminum EPR cable, 3\/0 AWG High voltage underground cable,5 kV to 46 kV aluminum cable,EPR insulated MV-90 cable, 3\/0 AWG EPR LLDPE cable, 3\/0 AWG MV-90 primary UD 46 kV cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 3\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.85\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 16\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e12 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 50\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.18\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 907\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52222326407537,"sku":"NNCU03\/0LLDPE","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-29T171334.898.png?v=1763023724"},{"product_id":"4-0-awg-19-str-aluminum-primary-ud-cable-14-awg-full-neutral-epr-lldpe-mv-90-100-175-mil-15-kv","title":"4\/0 AWG 19 Str Aluminum Primary UD Cable 14 AWG Full Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_2.pdf?v=1743233112\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e4\/0 AWG 19 Str Aluminum Primary UD Cable 14 AWG Full Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e4\/0 AWG Aluminum EPR cable, 4\/0 AWG High voltage underground cable,5 kV to 46 kV aluminum cable,EPR insulated MV-90 cable, 4\/0 AWG EPR LLDPE cable, 4\/0 AWG MV-90 primary UD 46 kV cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 4\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.90\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 32\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e14 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 50\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.21\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 1034\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52222328635761,"sku":"NNCU4\/0LLDPE","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-29T171334.898.png?v=1763023724"},{"product_id":"4-0-awg-19-str-aluminum-primary-ud-cable-12-awg-full-neutral-epr-lldpe-mv-90-100-175-mil-15-kv","title":"4\/0 AWG 19 Str Aluminum Primary UD Cable 12 AWG Full Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_2.pdf?v=1743233112\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e4\/0 AWG 19 Str Aluminum Primary UD Cable 12 AWG Full Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e4\/0 AWG Aluminum EPR cable, 4\/0 AWG High voltage underground cable,5 kV to 46 kV aluminum cable,EPR insulated MV-90 cable, 4\/0 AWG EPR LLDPE cable, 4\/0 AWG MV-90 primary UD 46 kV cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 4\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.90\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 20\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e12 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 50\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.24 \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 1058\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52222331027825,"sku":"NNCU04\/0LLDPE","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-29T171334.898.png?v=1763023724"},{"product_id":"4-0-awg-19-str-aluminum-primary-ud-cable-10-awg-full-neutral-epr-lldpe-mv-90-100-175-mil-15-kv","title":"4\/0 AWG 19 Str Aluminum Primary UD Cable 10 AWG Full Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_2.pdf?v=1743233112\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e4\/0 AWG 19 Str Aluminum Primary UD Cable 10 AWG Full Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e4\/0 AWG Aluminum EPR cable, 4\/0 AWG High voltage underground cable,5 kV to 46 kV aluminum cable,EPR insulated MV-90 cable, 4\/0 AWG EPR LLDPE cable, 4\/0 AWG MV-90 primary UD 46 kV cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 4\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.90\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 13\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e10 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 50\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.28\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 1104\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52222333321585,"sku":"NNCU14\/0LLDPE","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-29T171334.898.png?v=1763023724"},{"product_id":"250-mcm-37-str-aluminum-primary-ud-cable-12-awg-full-neutral-epr-lldpe-mv-90-100-175-mil-15-kv","title":"250 MCM 37 Str Aluminum Primary UD Cable 12 AWG Full Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_2.pdf?v=1743233112\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e250 MCM 37 Str Aluminum Primary UD Cable 12 AWG Full Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e250 MCM Aluminum EPR cable, 250 MCM High voltage underground cable,5 kV to 46 kV aluminum cable,EPR insulated MV-90 cable, 250 MCM EPR LLDPE cable, 250 MCM MV-90 primary UD 46 kV cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 250 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 37\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.96\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 25\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e12 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 50\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 1220\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52222346330481,"sku":"NNCU250LLDPE","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-29T171334.898.png?v=1763023724"},{"product_id":"250-mcm-37-str-aluminum-primary-ud-cable-10-awg-full-neutral-epr-lldpe-mv-90-100-175-mil-15-kv","title":"250 MCM 37 Str Aluminum Primary UD Cable 10 AWG Full Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_2.pdf?v=1743233112\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e250 MCM 37 Str Aluminum Primary UD Cable 10 AWG Full Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e250 MCM Aluminum EPR cable, 250 MCM High voltage underground cable,5 kV to 46 kV aluminum cable,EPR insulated MV-90 cable, 250 MCM EPR LLDPE cable, 250 MCM MV-90 primary UD 46 kV cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 250 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 37\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.96\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 16\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e10 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 50\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.34\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 1264\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52222351507825,"sku":"NNCU0250LLDPE","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-29T171334.898.png?v=1763023724"},{"product_id":"350-mcm-37-str-aluminum-primary-ud-cable-12-awg-full-neutral-epr-lldpe-mv-90-100-175-mil-15-kv","title":"350 MCM 37 Str Aluminum Primary UD Cable 12 AWG Full Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_2.pdf?v=1743233112\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e350 MCM 37 Str Aluminum Primary UD Cable 12 AWG Full Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e350 MCM Aluminum EPR cable, 350 MCM High voltage underground cable,5 kV to 46 kV aluminum cable,EPR insulated MV-90 cable, 350 MCM EPR LLDPE cable, 350 MCM MV-90 primary UD 46 kV cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 350 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 37\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.06\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 32\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e12 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 50\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.42\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 1532\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52222355505521,"sku":"NNCU350LLDPE","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-29T171334.898.png?v=1763023724"},{"product_id":"350-mcm-37-str-aluminum-primary-ud-cable-10-awg-full-neutral-epr-lldpe-mv-90-100-175-mil-15-kv","title":"350 MCM 37 Str Aluminum Primary UD Cable 10 AWG Full Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_2.pdf?v=1743233112\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e350 MCM 37 Str Aluminum Primary UD Cable 10 AWG Full Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e350 MCM Aluminum EPR cable, 350 MCM High voltage underground cable,5 kV to 46 kV aluminum cable,EPR insulated MV-90 cable, 350 MCM EPR LLDPE cable, 350 MCM MV-90 primary UD 46 kV cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 350 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 37\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.06\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 20\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e10 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 50\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.46\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 1567\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52222378082673,"sku":"NNCU0350LLDPE","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-29T171334.898.png?v=1763023724"},{"product_id":"350-mcm-37-str-aluminum-primary-ud-cable-9-awg-full-neutral-epr-lldpe-mv-90-100-175-mil-15-kv","title":"350 MCM 37 Str Aluminum Primary UD Cable 9 AWG Full Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_2.pdf?v=1743233112\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e350 MCM 37 Str Aluminum Primary UD Cable 9 AWG Full Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e350 MCM Aluminum EPR cable, 350 MCM High voltage underground cable,5 kV to 46 kV aluminum cable,EPR insulated MV-90 cable, 350 MCM EPR LLDPE cable, 350 MCM MV-90 primary UD 46 kV cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 350 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 37\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.06\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 16\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e9 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 50\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.49\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 1595\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52222388863345,"sku":"NNCU1350LLDPE","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-29T171334.898.png?v=1763023724"},{"product_id":"500-mcm-37-str-aluminum-primary-ud-cable-10-awg-full-neutral-epr-lldpe-mv-90-100-175-mil-15-kv","title":"500 MCM 37 Str Aluminum Primary UD Cable 10 AWG Full Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_2.pdf?v=1743233112\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e500 MCM 37 Str Aluminum Primary UD Cable 10 AWG Full Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e500 MCM Aluminum EPR cable, 500 MCM High voltage underground cable,5 kV to 46 kV aluminum cable,EPR insulated MV-90 cable, 500 MCM EPR LLDPE cable, 500 MCM MV-90 primary UD 46 kV cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 500 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 37\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.19\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 29\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e10 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 50\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.59\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 2060\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52222399021425,"sku":"NNCU500LLDPE","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-29T171334.898.png?v=1763023724"},{"product_id":"750-mcm-61-str-aluminum-primary-ud-cable-8-awg-full-neutral-epr-lldpe-mv-90-100-175-mil-15-kv","title":"750 MCM 61 Str Aluminum Primary UD Cable 8 AWG Full Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_2.pdf?v=1743233112\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e750 MCM 61 Str Aluminum Primary UD Cable 8 AWG Full Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e750 MCM Aluminum EPR cable, 750 MCM High voltage underground cable,5 kV to 46 kV aluminum cable,EPR insulated MV-90 cable, 750 MCM EPR LLDPE cable, 750 MCM MV-90 primary UD 46 kV cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 750 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 61\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.40 \u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 28\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e8 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.91\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 3043\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52222443127153,"sku":"NNCU750LLDPE","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-29T171334.898.png?v=1763023724"},{"product_id":"1000-mcm-61-str-aluminum-primary-ud-cable-8-awg-full-neutral-epr-lldpe-mv-90-100-175-mil-15-kv","title":"1000 MCM 61 Str Aluminum Primary UD Cable 8 AWG Full Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_2.pdf?v=1743233112\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1000 MCM 61 Str Aluminum Primary UD Cable 8 AWG Full Neutral EPR \/ LLDPE MV-90 100% 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1000 MCM Aluminum EPR cable, 1000 MCM High voltage underground cable,5 kV to 46 kV aluminum cable,EPR insulated MV-90 cable, 1000 MCM EPR LLDPE cable, 1000 MCM MV-90 primary UD 46 kV cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1000 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 61\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.54\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 37\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e8 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 2.09 \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 3868\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52222453842289,"sku":"NNCU11000LLDPE","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-29T171334.898.png?v=1763023724"},{"product_id":"1-0-awg-19-str-aluminum-primary-ud-cable-14-awg-1-3-neutral-epr-lldpe-mv-90-133-420-mil-35-kv","title":"1\/0 AWG 19 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 133% 420 mil 35 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_2.pdf?v=1743233112\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1\/0 AWG 19 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 133% 420 mil 35 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1\/0 AWG Aluminum EPR cable, 1\/0 AWG High voltage underground cable,5 kV to 46 kV aluminum cable,EPR insulated MV-90 cable, 1\/0 AWG EPR LLDPE cable, 1\/0 AWG MV-90 primary UD 46 kV cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.25\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 6\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e14 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 50\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.57\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 1076\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52225862402417,"sku":"NNCT1\/0LLDPE","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitleddesign-2025-04-29T171334.898.png?v=1763023858"},{"product_id":"2-0-awg-19-str-aluminum-primary-ud-cable-14-awg-1-3-neutral-epr-lldpe-mv-90-133-420-mil-35-kv","title":"2\/0 AWG 19 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 133% 420 mil 35 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_2.pdf?v=1743233112\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2\/0 AWG 19 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 133% 420 mil 35 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e2\/0 AWG Aluminum EPR cable, 2\/0 AWG High voltage underground cable,5 kV to 46 kV aluminum cable,EPR insulated MV-90 cable, 2\/0 AWG EPR LLDPE cable, 2\/0 AWG MV-90 primary UD 46 kV cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.29\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 7\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e14 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 50\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.62\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 1157\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52225873805681,"sku":"NNCT2\/0LLDPE","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitleddesign-2025-04-29T171334.898.png?v=1763023858"},{"product_id":"3-0-awg-19-str-aluminum-primary-ud-cable-14-awg-1-3-neutral-epr-lldpe-mv-90-133-420-mil-35-kv","title":"3\/0 AWG 19 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 133% 420 mil 35 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_2.pdf?v=1743233112\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e3\/0 AWG 19 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 133% 420 mil 35 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e3\/0 AWG Aluminum EPR cable, 3\/0 AWG High voltage underground cable,5 kV to 46 kV aluminum cable,EPR insulated MV-90 cable, 3\/0 AWG EPR LLDPE cable, 3\/0 AWG MV-90 primary UD 46 kV cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 3\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.34\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 9\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e14 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.73 \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 1331\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52225876427121,"sku":"NNCT3\/0LLDPE","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitleddesign-2025-04-29T171334.898.png?v=1763023858"},{"product_id":"4-0-awg-19-str-aluminum-primary-ud-cable-14-awg-1-3-neutral-epr-lldpe-mv-90-133-420-mil-35-kv","title":"4\/0 AWG 19 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 133% 420 mil 35 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_2.pdf?v=1743233112\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e4\/0 AWG 19 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 133% 420 mil 35 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e4\/0 AWG Aluminum EPR cable, 4\/0 AWG High voltage underground cable,5 kV to 46 kV aluminum cable,EPR insulated MV-90 cable, 4\/0 AWG EPR LLDPE cable, 4\/0 AWG MV-90 primary UD 46 kV cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 4\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.40 \u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 11 \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e14 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.79\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 1454\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52225879441777,"sku":"NNCT4\/0LLDPE","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitleddesign-2025-04-29T171334.898.png?v=1763023858"},{"product_id":"250-mcm-37-str-aluminum-primary-ud-cable-14-awg-1-3-neutral-epr-lldpe-mv-90-133-420-mil-35-kv","title":"250 MCM 37 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 133% 420 mil 35 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_2.pdf?v=1743233112\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e250 MCM 37 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 133% 420 mil 35 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e250 MCM Aluminum EPR cable, 250 MCM High voltage underground cable,5 kV to 46 kV aluminum cable,EPR insulated MV-90 cable, 250 MCM EPR LLDPE cable, 250 MCM MV-90 primary UD 46 kV cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 250 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 37 \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.45 \u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 13\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e14 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.84\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 1571\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52225883144561,"sku":"NNCT250LLDPE","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitleddesign-2025-04-29T171334.898.png?v=1763023858"},{"product_id":"350-mcm-37-str-aluminum-primary-ud-cable-14-awg-1-3-neutral-epr-lldpe-mv-90-133-420-mil-35-kv","title":"350 MCM 37 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 133% 420 mil 35 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_2.pdf?v=1743233112\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e350 MCM 37 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 133% 420 mil 35 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e350 MCM Aluminum EPR cable, 350 MCM High voltage underground cable,5 kV to 46 kV aluminum cable,EPR insulated MV-90 cable, 350 MCM EPR LLDPE cable, 350 MCM MV-90 primary UD 46 kV cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 350 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 37 \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.56  \u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 18\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e14 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.98\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 1876\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52225887338865,"sku":"NNCT350LLDPE","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitleddesign-2025-04-29T171334.898.png?v=1763023858"},{"product_id":"500-mcm-37-str-aluminum-primary-ud-cable-14-awg-1-3-neutral-epr-lldpe-mv-90-133-420-mil-35-kv","title":"500 MCM 37 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 133% 420 mil 35 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_2.pdf?v=1743233112\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e500 MCM 37 Str Aluminum Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 133% 420 mil 35 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e500 MCM Aluminum EPR cable, 500 MCM High voltage underground cable,5 kV to 46 kV aluminum cable,EPR insulated MV-90 cable, 500 MCM EPR LLDPE cable, 500 MCM MV-90 primary UD 46 kV cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 500 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 37 \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.68 \u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 25\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e14 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 2.11\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 2235 \u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52225891139953,"sku":"NNCT500LLDPE","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitleddesign-2025-04-29T171334.898.png?v=1763023858"},{"product_id":"500-mcm-37-str-aluminum-primary-ud-cable-12-awg-1-3-neutral-epr-lldpe-mv-90-133-420-mil-35-kv","title":"500 MCM 37 Str Aluminum Primary UD Cable 12 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 133% 420 mil 35 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_2.pdf?v=1743233112\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e500 MCM 37 Str Aluminum Primary UD Cable 12 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 133% 420 mil 35 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e500 MCM Aluminum EPR cable, 500 MCM High voltage underground cable,5 kV to 46 kV aluminum cable,EPR insulated MV-90 cable, 500 MCM EPR LLDPE cable, 500 MCM MV-90 primary UD 46 kV cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 500 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 37 \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.68 \u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 16\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e12 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 2.14\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 2285\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52225913323889,"sku":"NNCT0500LLDPE","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitleddesign-2025-04-29T171334.898.png?v=1763023858"},{"product_id":"750-mcm-61-str-aluminum-primary-ud-cable-12-awg-1-3-neutral-epr-lldpe-mv-90-133-420-mil-35-kv","title":"750 MCM 61 Str Aluminum Primary UD Cable 12 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 133% 420 mil 35 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_2.pdf?v=1743233112\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e750 MCM 61 Str Aluminum Primary UD Cable 12 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 133% 420 mil 35 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e750 MCM Aluminum EPR cable, 750 MCM High voltage underground cable,5 kV to 46 kV aluminum cable,EPR insulated MV-90 cable, 750 MCM EPR LLDPE cable, 750 MCM MV-90 primary UD 46 kV cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 750 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 61\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.89\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 24\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e12 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 2.34 \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 2902\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52225916141937,"sku":"NNCT750LLDPE","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitleddesign-2025-04-29T171334.898.png?v=1763023858"},{"product_id":"750-mcm-61-str-aluminum-primary-ud-cable-10-awg-1-3-neutral-epr-lldpe-mv-90-133-420-mil-35-kv","title":"750 MCM 61 Str Aluminum Primary UD Cable 10 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 133% 420 mil 35 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_2.pdf?v=1743233112\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e750 MCM 61 Str Aluminum Primary UD Cable 10 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 133% 420 mil 35 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e750 MCM Aluminum EPR cable, 750 MCM High voltage underground cable,5 kV to 46 kV aluminum cable,EPR insulated MV-90 cable, 750 MCM EPR LLDPE cable, 750 MCM MV-90 primary UD 46 kV cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 750 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 61\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.89\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 15\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e10 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 2.39\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 2963\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52225919123825,"sku":"NNCT0750LLDPE","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitleddesign-2025-04-29T171334.898.png?v=1763023858"},{"product_id":"1000-mcm-61-str-aluminum-primary-ud-cable-9-awg-1-3-neutral-epr-lldpe-mv-90-133-420-mil-35-kv","title":"1000 MCM 61 Str Aluminum Primary UD Cable 9 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 133% 420 mil 35 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_2.pdf?v=1743233112\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1000 MCM 61 Str Aluminum Primary UD Cable 9 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 133% 420 mil 35 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1000 MCM Aluminum EPR cable, 1000 MCM High voltage underground cable,5 kV to 46 kV aluminum cable,EPR insulated MV-90 cable, 1000 MCM EPR LLDPE cable, 1000 MCM MV-90 primary UD 46 kV cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1000 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 61\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 2.04\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 16\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e9 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 2.56\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 3560 \u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52225925218673,"sku":"NNCT1000LLDPE","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitleddesign-2025-04-29T171334.898.png?v=1763023858"},{"product_id":"1-0-awg-19-str-aluminum-primary-ud-cable-14-awg-full-neutral-epr-lldpe-mv-90-133-420-mil-35-kv","title":"1\/0 AWG 19 Str Aluminum Primary UD Cable 14 AWG Full Neutral EPR \/ LLDPE MV-90 133% 420 mil 35 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_2.pdf?v=1743233112\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1\/0 AWG 19 Str Aluminum Primary UD Cable 14 AWG Full Neutral EPR \/ LLDPE MV-90 133% 420 mil 35 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1\/0 AWG Aluminum EPR cable, 1\/0 AWG High voltage underground cable,5 kV to 46 kV aluminum cable,EPR insulated MV-90 cable, 1\/0 AWG EPR LLDPE cable, 1\/0 AWG MV-90 primary UD 46 kV cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eHard drawn aluminum Class B compressed or unilay compressed stranding per ASTM B231. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.25\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 16\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e14 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e\u003cspan\u003e 50\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.57\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 1196\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52225939505521,"sku":"NNCR1\/0TLLDPE","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitleddesign-2025-04-29T171334.898.png?v=1763023858"}],"url":"https:\/\/nassaunationalcable.com\/en-ca\/collections\/aluminum-epr-lldpe-concentric-neutral-mv-90-primary-ud-cable-5-kv-46-kv.oembed?page=5","provider":"NassauNationalCable","version":"1.0","type":"link"}