{"title":"Aluminum 3C MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV","description":"","products":[{"product_id":"8-awg-3c-aluminum-mv-90-non-shielded-epr-insulated-pvc-jacketed-2-4-kv","title":"8 AWG 3C Aluminum MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/ilovepdf_merged_2.pdf?v=1735636134\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e8 AWG 3C Aluminum MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Per NEC, use is limited to 2400 volts maximum\u003cbr\u003e• For use in power system in industrial establishments and utility applications, for dry locations, in accordance with NEC.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e8 AWG Aluminum MV-90 Cable, 8 AWG 3C 2.4kV Non-Shielded Cable, 8 AWG EPR Insulated PVC Cable, 8 AWG Medium Voltage 3C Aluminum, 8 AWG 2.4 kV EPR Cable, 8 AWG Non-Shielded PVC Jacketed Cable, 8 AWG 3 Conductor MV-90 Cable, 8 AWG  Aluminum EPR Cable 2.4 kV, 8 AWG MV-90 3C PVC Cable, 8 AWG 2.4 kV Aluminum Non-Shielded Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• UL 1072\u003cbr\u003e• Medium Voltage Power Cables.\u003cbr\u003e• ICEA S-96-659\/NEMA WC71\u003cbr\u003e• Standard for Nonshielded Cables Rated 2001-5000 Volts for Use in the Distribution of Electrical Energy.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• UL Listed as MV-90.\u003cbr\u003e• Rated For CT use 1\/0 AWG and up.\u003cbr\u003e• Jacket is listed Sunlight Resistant and Oil Resistant I.\u003cbr\u003e• Jacket is flame retardant.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e hard drawn Aluminum-1350 compacted Class B per ASTM B400.(6 AWG Aluminum) up to 1000 kcmil.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermoplastic polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 8 AWG \u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 7\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.13\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Insulation Thickness (mil):\u003c\/strong\u003e 90\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 80\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 0.96\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 475\u003cbr\u003e• \u003cstrong\u003eAmpacity 90 °C:\u003c\/strong\u003e 65\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52057759973745,"sku":"NNC08MVEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/60_0b2e69fe-1bd7-437a-a908-96cd120a9ac8.png?v=1763020042"},{"product_id":"6-awg-3c-aluminum-mv-90-non-shielded-epr-insulated-pvc-jacketed-2-4-kv","title":"6 AWG 3C Aluminum MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/ilovepdf_merged_2.pdf?v=1735636134\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e6 AWG 3C Aluminum MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Per NEC, use is limited to 2400 volts maximum\u003cbr\u003e• For use in power system in industrial establishments and utility applications, for dry locations, in accordance with NEC.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e6 AWG Aluminum MV-90 Cable, 6 AWG 3C 2.4kV Non-Shielded Cable, 6 AWG EPR Insulated PVC Cable, 6 AWG Medium Voltage 3C Aluminum, 6 AWG 2.4 kV EPR Cable, 6 AWG Non-Shielded PVC Jacketed Cable, 6 AWG 3 Conductor MV-90 Cable, 6 AWG  Aluminum EPR Cable 2.4 kV, 6 AWG MV-90 3C PVC Cable, 6 AWG 2.4 kV Aluminum Non-Shielded Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• UL 1072\u003cbr\u003e• Medium Voltage Power Cables.\u003cbr\u003e• ICEA S-96-659\/NEMA WC71\u003cbr\u003e• Standard for Nonshielded Cables Rated 2001-5000 Volts for Use in the Distribution of Electrical Energy.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• UL Listed as MV-90.\u003cbr\u003e• Rated For CT use 1\/0 AWG and up.\u003cbr\u003e• Jacket is listed Sunlight Resistant and Oil Resistant I.\u003cbr\u003e• Jacket is flame retardant.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e hard drawn Aluminum-1350 compacted Class B per ASTM B400.(6 AWG Aluminum) up to 1000 kcmil.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermoplastic polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 6 AWG \u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 7\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.17\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Insulation Thickness (mil):\u003c\/strong\u003e 90\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG :\u003c\/strong\u003e 6\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 80\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 1.03\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 515\u003cbr\u003e• \u003cstrong\u003eAmpacity 90 °C:\u003c\/strong\u003e 80\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52057760563569,"sku":"NNC06MVEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/60_0b2e69fe-1bd7-437a-a908-96cd120a9ac8.png?v=1763020042"},{"product_id":"4-awg-3c-aluminum-mv-90-non-shielded-epr-insulated-pvc-jacketed-2-4-kv","title":"4 AWG 3C Aluminum MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/ilovepdf_merged_2.pdf?v=1735636134\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e4 AWG 3C Aluminum MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Per NEC, use is limited to 2400 volts maximum\u003cbr\u003e• For use in power system in industrial establishments and utility applications, for dry locations, in accordance with NEC.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e4 AWG Aluminum MV-90 Cable, 4 AWG 3C 2.4kV Non-Shielded Cable, 4 AWG EPR Insulated PVC Cable, 4 AWG Medium Voltage 3C Aluminum, 4 AWG 2.4 kV EPR Cable, 4 AWG Non-Shielded PVC Jacketed Cable, 4 AWG 3 Conductor MV-90 Cable, 4 AWG  Aluminum EPR Cable 2.4 kV, 4 AWG MV-90 3C PVC Cable, 4 AWG 2.4 kV Aluminum Non-Shielded Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• UL 1072\u003cbr\u003e• Medium Voltage Power Cables.\u003cbr\u003e• ICEA S-96-659\/NEMA WC71\u003cbr\u003e• Standard for Nonshielded Cables Rated 2001-5000 Volts for Use in the Distribution of Electrical Energy.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• UL Listed as MV-90.\u003cbr\u003e• Rated For CT use 1\/0 AWG and up.\u003cbr\u003e• Jacket is listed Sunlight Resistant and Oil Resistant I.\u003cbr\u003e• Jacket is flame retardant.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e hard drawn Aluminum-1350 compacted Class B per ASTM B400.(6 AWG Aluminum) up to 1000 kcmil.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermoplastic polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 4 AWG \u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 7\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.21\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Insulation Thickness (mil):\u003c\/strong\u003e 90\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG :\u003c\/strong\u003e 4\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 80\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 1.13\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 614\u003cbr\u003e• \u003cstrong\u003eAmpacity 90 °C:\u003c\/strong\u003e 105\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52057764856177,"sku":"NNC04MVEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/60_0b2e69fe-1bd7-437a-a908-96cd120a9ac8.png?v=1763020042"},{"product_id":"2-awg-3c-aluminum-mv-90-non-shielded-epr-insulated-pvc-jacketed-2-4-kv","title":"2 AWG 3C Aluminum MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/ilovepdf_merged_2.pdf?v=1735636134\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2 AWG 3C Aluminum MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Per NEC, use is limited to 2400 volts maximum\u003cbr\u003e• For use in power system in industrial establishments and utility applications, for dry locations, in accordance with NEC.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e2 AWG Aluminum MV-90 Cable, 2 AWG 3C 2.4kV Non-Shielded Cable, 2 AWG EPR Insulated PVC Cable, 2 AWG Medium Voltage 3C Aluminum, 2 AWG 2.4 kV EPR Cable, 2 AWG Non-Shielded PVC Jacketed Cable, 2 AWG 3 Conductor MV-90 Cable, 2 AWG  Aluminum EPR Cable 2.4 kV, 2 AWG MV-90 3C PVC Cable, 2 AWG 2.4 kV Aluminum Non-Shielded Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• UL 1072\u003cbr\u003e• Medium Voltage Power Cables.\u003cbr\u003e• ICEA S-96-659\/NEMA WC71\u003cbr\u003e• Standard for Nonshielded Cables Rated 2001-5000 Volts for Use in the Distribution of Electrical Energy.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• UL Listed as MV-90.\u003cbr\u003e• Rated For CT use 1\/0 AWG and up.\u003cbr\u003e• Jacket is listed Sunlight Resistant and Oil Resistant I.\u003cbr\u003e• Jacket is flame retardant.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e hard drawn Aluminum-1350 compacted Class B per ASTM B400.(6 AWG Aluminum) up to 1000 kcmil.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermoplastic polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2 AWG \u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 7\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.27\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Insulation Thickness (mil):\u003c\/strong\u003e 90\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG :\u003c\/strong\u003e 4\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 80\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 1.25\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 755\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e• \u003cstrong\u003eAmpacity 90 °C:\u003c\/strong\u003e 140\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52057769804145,"sku":"NNC02MVEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/60_0b2e69fe-1bd7-437a-a908-96cd120a9ac8.png?v=1763020042"},{"product_id":"1-awg-3c-aluminum-mv-90-non-shielded-epr-insulated-pvc-jacketed-2-4-kv","title":"1 AWG 3C Aluminum MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/ilovepdf_merged_2.pdf?v=1735636134\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1 AWG 3C Aluminum MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Per NEC, use is limited to 2400 volts maximum\u003cbr\u003e• For use in power system in industrial establishments and utility applications, for dry locations, in accordance with NEC.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1 AWG Aluminum MV-90 Cable, 1 AWG 3C 2.4kV Non-Shielded Cable, 1 AWG EPR Insulated PVC Cable, 1 AWG Medium Voltage 3C Aluminum, 1 AWG 2.4 kV EPR Cable, 1 AWG Non-Shielded PVC Jacketed Cable, 1 AWG 3 Conductor MV-90 Cable, 1 AWG  Aluminum EPR Cable 2.4 kV, 1 AWG MV-90 3C PVC Cable, 1 AWG 2.4 kV Aluminum Non-Shielded Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• UL 1072\u003cbr\u003e• Medium Voltage Power Cables.\u003cbr\u003e• ICEA S-96-659\/NEMA WC71\u003cbr\u003e• Standard for Nonshielded Cables Rated 2001-5000 Volts for Use in the Distribution of Electrical Energy.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• UL Listed as MV-90.\u003cbr\u003e• Rated For CT use 1\/0 AWG and up.\u003cbr\u003e• Jacket is listed Sunlight Resistant and Oil Resistant I.\u003cbr\u003e• Jacket is flame retardant.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e hard drawn Aluminum-1350 compacted Class B per ASTM B400.(6 AWG Aluminum) up to 1000 kcmil.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermoplastic polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1 AWG \u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.30\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Insulation Thickness (mil):\u003c\/strong\u003e 90\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG :\u003c\/strong\u003e 4\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 80\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 1.31\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 883\u003cbr\u003e• \u003cstrong\u003eAmpacity 90 °C:\u003c\/strong\u003e 155\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52057771409777,"sku":"NNC01MVEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/60_0b2e69fe-1bd7-437a-a908-96cd120a9ac8.png?v=1763020042"},{"product_id":"1-0-awg-3c-aluminum-mv-90-non-shielded-epr-insulated-pvc-jacketed-2-4-kv","title":"1\/0 AWG 3C Aluminum MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/ilovepdf_merged_2.pdf?v=1735636134\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1\/0 AWG 3C Aluminum MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Per NEC, use is limited to 2400 volts maximum\u003cbr\u003e• For use in power system in industrial establishments and utility applications, for dry locations, in accordance with NEC.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1\/0 AWG Aluminum MV-90 Cable, 1\/0 AWG 3C 2.4kV Non-Shielded Cable, 1\/0 AWG EPR Insulated PVC Cable, 1\/0 AWG Medium Voltage 3C Aluminum, 1\/0  AWG 2.4 kV EPR Cable, 1\/0 AWG Non-Shielded PVC Jacketed Cable, 1\/0  AWG 3 Conductor MV-90 Cable, 1\/0 AWG Aluminum EPR Cable 2.4 kV, 1\/0 AWG MV-90 3C PVC Cable, 1\/0 AWG 2.4 kV Aluminum Non-Shielded Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• UL 1072\u003cbr\u003e• Medium Voltage Power Cables.\u003cbr\u003e• ICEA S-96-659\/NEMA WC71\u003cbr\u003e• Standard for Nonshielded Cables Rated 2001-5000 Volts for Use in the Distribution of Electrical Energy.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• UL Listed as MV-90.\u003cbr\u003e• Rated For CT use 1\/0 AWG and up.\u003cbr\u003e• Jacket is listed Sunlight Resistant and Oil Resistant I.\u003cbr\u003e• Jacket is flame retardant.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e hard drawn Aluminum-1350 compacted Class B per ASTM B400.(6 AWG Aluminum) up to 1000 kcmil.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermoplastic polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1\/0 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.34\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Insulation Thickness (mil):\u003c\/strong\u003e 90\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG :\u003c\/strong\u003e 4\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 80\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 1.39\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 993\u003cbr\u003e• \u003cstrong\u003eAmpacity 90 °C:\u003c\/strong\u003e 180\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52057772556657,"sku":"NNC10MVEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/60_0b2e69fe-1bd7-437a-a908-96cd120a9ac8.png?v=1763020042"},{"product_id":"2-0-awg-3c-aluminum-mv-90-non-shielded-epr-insulated-pvc-jacketed-2-4-kv","title":"2\/0 AWG 3C Aluminum MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/ilovepdf_merged_2.pdf?v=1735636134\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2\/0 AWG 3C Aluminum MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Per NEC, use is limited to 2400 volts maximum\u003cbr\u003e• For use in power system in industrial establishments and utility applications, for dry locations, in accordance with NEC.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e2\/0 AWG Aluminum MV-90 Cable, 2\/0 AWG 3C 2.4kV Non-Shielded Cable, 2\/0 AWG EPR Insulated PVC Cable, 2\/0 AWG Medium Voltage 3C Aluminum, 2\/0 AWG 2.4 kV EPR Cable, 2\/0 AWG Non-Shielded PVC Jacketed Cable, 2\/0 AWG 3 Conductor MV-90 Cable, 2\/0 AWG Aluminum EPR Cable 2.4 kV, 2\/0 AWG MV-90 3C PVC Cable, 2\/0 AWG 2.4 kV Aluminum Non-Shielded Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• UL 1072\u003cbr\u003e• Medium Voltage Power Cables.\u003cbr\u003e• ICEA S-96-659\/NEMA WC71\u003cbr\u003e• Standard for Nonshielded Cables Rated 2001-5000 Volts for Use in the Distribution of Electrical Energy.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• UL Listed as MV-90.\u003cbr\u003e• Rated For CT use 1\/0 AWG and up.\u003cbr\u003e• Jacket is listed Sunlight Resistant and Oil Resistant I.\u003cbr\u003e• Jacket is flame retardant.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e hard drawn Aluminum-1350 compacted Class B per ASTM B400.(6 AWG Aluminum) up to 1000 kcmil.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermoplastic polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2\/0 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.38\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Insulation Thickness (mil):\u003c\/strong\u003e 90\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG :\u003c\/strong\u003e 2\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 80\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 1.48\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 1128\u003cbr\u003e• \u003cstrong\u003eAmpacity 90 °C:\u003c\/strong\u003e 205\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52057772949873,"sku":"NNC20MVEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/60_0b2e69fe-1bd7-437a-a908-96cd120a9ac8.png?v=1763020042"},{"product_id":"3-0-awg-3c-aluminum-mv-90-non-shielded-epr-insulated-pvc-jacketed-2-4-kv","title":"3\/0 AWG 3C Aluminum MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/ilovepdf_merged_2.pdf?v=1735636134\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e3\/0 AWG 3C Aluminum MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Per NEC, use is limited to 2400 volts maximum\u003cbr\u003e• For use in power system in industrial establishments and utility applications, for dry locations, in accordance with NEC.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e3\/0 AWG Aluminum MV-90 Cable, 3\/0 AWG 3C 2.4kV Non-Shielded Cable, 3\/0 AWG EPR Insulated PVC Cable, 3\/0 AWG Medium Voltage 3C Aluminum, 3\/0 AWG 2.4 kV EPR Cable, 3\/0 AWG Non-Shielded PVC Jacketed Cable, 3\/0 AWG 3 Conductor MV-90 Cable, 3\/0 AWG Aluminum EPR Cable 2.4 kV, 3\/0 AWG MV-90 3C PVC Cable, 3\/0 AWG 2.4 kV Aluminum Non-Shielded Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• UL 1072\u003cbr\u003e• Medium Voltage Power Cables.\u003cbr\u003e• ICEA S-96-659\/NEMA WC71\u003cbr\u003e• Standard for Nonshielded Cables Rated 2001-5000 Volts for Use in the Distribution of Electrical Energy.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• UL Listed as MV-90.\u003cbr\u003e• Rated For CT use 1\/0 AWG and up.\u003cbr\u003e• Jacket is listed Sunlight Resistant and Oil Resistant I.\u003cbr\u003e• Jacket is flame retardant.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e hard drawn Aluminum-1350 compacted Class B per ASTM B400.(6 AWG Aluminum) up to 1000 kcmil.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermoplastic polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 3\/0 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.42\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Insulation Thickness (mil):\u003c\/strong\u003e 90\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG :\u003c\/strong\u003e 2\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 80\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 1.58\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 1321\u003cbr\u003e• \u003cstrong\u003eAmpacity 90 °C:\u003c\/strong\u003e 230\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52057812074865,"sku":"NNC30MVEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/60_0b2e69fe-1bd7-437a-a908-96cd120a9ac8.png?v=1763020042"},{"product_id":"4-0-awg-3c-aluminum-mv-90-non-shielded-epr-insulated-pvc-jacketed-2-4-kv","title":"4\/0 AWG 3C Aluminum MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/ilovepdf_merged_2.pdf?v=1735636134\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e4\/0 AWG 3C Aluminum MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Per NEC, use is limited to 2400 volts maximum\u003cbr\u003e• For use in power system in industrial establishments and utility applications, for dry locations, in accordance with NEC.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e4\/0 AWG Aluminum MV-90 Cable, 4\/0 AWG 3C 2.4kV Non-Shielded Cable, 4\/0 AWG EPR Insulated PVC Cable, 4\/0 AWG Medium Voltage 3C Aluminum, 4\/0 AWG 2.4 kV EPR Cable, 4\/0 AWG Non-Shielded PVC Jacketed Cable, 4\/0 AWG 3 Conductor MV-90 Cable, 4\/0 AWG Aluminum EPR Cable 2.4 kV, 4\/0 AWG MV-90 3C PVC Cable, 4\/0 AWG 2.4 kV Aluminum Non-Shielded Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• UL 1072\u003cbr\u003e• Medium Voltage Power Cables.\u003cbr\u003e• ICEA S-96-659\/NEMA WC71\u003cbr\u003e• Standard for Nonshielded Cables Rated 2001-5000 Volts for Use in the Distribution of Electrical Energy.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• UL Listed as MV-90.\u003cbr\u003e• Rated For CT use 1\/0 AWG and up.\u003cbr\u003e• Jacket is listed Sunlight Resistant and Oil Resistant I.\u003cbr\u003e• Jacket is flame retardant.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e hard drawn Aluminum-1350 compacted Class B per ASTM B400.(6 AWG Aluminum) up to 1000 kcmil.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermoplastic polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 4\/0 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.48\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Insulation Thickness (mil):\u003c\/strong\u003e 90\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG :\u003c\/strong\u003e 2\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 1.76\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 1628\u003cbr\u003e• \u003cstrong\u003eAmpacity 90 °C:\u003c\/strong\u003e 260\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52058073989489,"sku":"NNC40MVEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/60_0b2e69fe-1bd7-437a-a908-96cd120a9ac8.png?v=1763020042"},{"product_id":"250-mcm-3c-aluminum-mv-90-non-shielded-epr-insulated-pvc-jacketed-2-4-kv","title":"250 MCM 3C Aluminum MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/ilovepdf_merged_2.pdf?v=1735636134\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e250 MCM 3C Aluminum MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Per NEC, use is limited to 2400 volts maximum\u003cbr\u003e• For use in power system in industrial establishments and utility applications, for dry locations, in accordance with NEC.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e250 MCM Aluminum MV-90 Cable, 250 MCM 3C 2.4kV Non-Shielded Cable, 250 MCM  EPR Insulated PVC Cable, 250 MCM Medium Voltage 3C Aluminum, 250 MCM 2.4 kV EPR Cable, 250 MCM  Non-Shielded PVC Jacketed Cable, 250 MCM  3 Conductor MV-90 Cable, 250 MCM Aluminum EPR Cable 2.4 kV, 250 MCM MV-90 3C PVC Cable, 250 MCM  2.4 kV Aluminum Non-Shielded Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• UL 1072\u003cbr\u003e• Medium Voltage Power Cables.\u003cbr\u003e• ICEA S-96-659\/NEMA WC71\u003cbr\u003e• Standard for Nonshielded Cables Rated 2001-5000 Volts for Use in the Distribution of Electrical Energy.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• UL Listed as MV-90.\u003cbr\u003e• Rated For CT use 1\/0 AWG and up.\u003cbr\u003e• Jacket is listed Sunlight Resistant and Oil Resistant I.\u003cbr\u003e• Jacket is flame retardant.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e hard drawn Aluminum-1350 compacted Class B per ASTM B400.(6 AWG Aluminum) up to 1000 kcmil.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermoplastic polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 250 MCM \u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 37\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.52\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Insulation Thickness (mil):\u003c\/strong\u003e 90\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG :\u003c\/strong\u003e 2\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 1.88\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 1860\u003cbr\u003e• \u003cstrong\u003eAmpacity 90 °C:\u003c\/strong\u003e 285\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52058074481009,"sku":"NNC250MVEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/60_0b2e69fe-1bd7-437a-a908-96cd120a9ac8.png?v=1763020042"},{"product_id":"300-mcm-3c-aluminum-mv-90-non-shielded-epr-insulated-pvc-jacketed-2-4-kv","title":"300 MCM 3C Aluminum MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/ilovepdf_merged_2.pdf?v=1735636134\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e300 MCM 3C Aluminum MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Per NEC, use is limited to 2400 volts maximum\u003cbr\u003e• For use in power system in industrial establishments and utility applications, for dry locations, in accordance with NEC.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e300 MCM Aluminum MV-90 Cable, 300 MCM 3C 2.4kV Non-Shielded Cable, 300 MCM  EPR Insulated PVC Cable, 300 MCM Medium Voltage 3C Aluminum, 300 MCM 2.4 kV EPR Cable, 300 MCM  Non-Shielded PVC Jacketed Cable, 300 MCM  3 Conductor MV-90 Cable, 300 MCM Aluminum EPR Cable 2.4 kV, 300 MCM MV-90 3C PVC Cable, 300 MCM  2.4 kV Aluminum Non-Shielded Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• UL 1072\u003cbr\u003e• Medium Voltage Power Cables.\u003cbr\u003e• ICEA S-96-659\/NEMA WC71\u003cbr\u003e• Standard for Nonshielded Cables Rated 2001-5000 Volts for Use in the Distribution of Electrical Energy.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• UL Listed as MV-90.\u003cbr\u003e• Rated For CT use 1\/0 AWG and up.\u003cbr\u003e• Jacket is listed Sunlight Resistant and Oil Resistant I.\u003cbr\u003e• Jacket is flame retardant.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e hard drawn Aluminum-1350 compacted Class B per ASTM B400.(6 AWG Aluminum) up to 1000 kcmil.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermoplastic polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 300 MCM \u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 37\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.57\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Insulation Thickness (mil):\u003c\/strong\u003e 90\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG :\u003c\/strong\u003e 1\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 1.99\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 2082\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52058075136369,"sku":"NNC300MVEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/60_0b2e69fe-1bd7-437a-a908-96cd120a9ac8.png?v=1763020042"},{"product_id":"350-mcm-3c-aluminum-mv-90-non-shielded-epr-insulated-pvc-jacketed-2-4-kv","title":"350 MCM 3C Aluminum MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/ilovepdf_merged_2.pdf?v=1735636134\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e350 MCM 3C Aluminum MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Per NEC, use is limited to 2400 volts maximum\u003cbr\u003e• For use in power system in industrial establishments and utility applications, for dry locations, in accordance with NEC.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e350 MCM Aluminum MV-90 Cable, 350 MCM 3C 2.4kV Non-Shielded Cable, 350 MCM  EPR Insulated PVC Cable, 350 MCM Medium Voltage 3C Aluminum, 350 MCM 2.4 kV EPR Cable, 350 MCM  Non-Shielded PVC Jacketed Cable, 350 MCM  3 Conductor MV-90 Cable, 350 MCM Aluminum EPR Cable 2.4 kV, 350 MCM MV-90 3C PVC Cable, 350 MCM  2.4 kV Aluminum Non-Shielded Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• UL 1072\u003cbr\u003e• Medium Voltage Power Cables.\u003cbr\u003e• ICEA S-96-659\/NEMA WC71\u003cbr\u003e• Standard for Nonshielded Cables Rated 2001-5000 Volts for Use in the Distribution of Electrical Energy.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• UL Listed as MV-90.\u003cbr\u003e• Rated For CT use 1\/0 AWG and up.\u003cbr\u003e• Jacket is listed Sunlight Resistant and Oil Resistant I.\u003cbr\u003e• Jacket is flame retardant.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e hard drawn Aluminum-1350 compacted Class B per ASTM B400.(6 AWG Aluminum) up to 1000 kcmil.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermoplastic polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 350 MCM \u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 37\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.62\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Insulation Thickness (mil):\u003c\/strong\u003e 90\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG :\u003c\/strong\u003e 1\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 2.08\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 2304\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e• \u003cstrong\u003eAmpacity 90 °C:\u003c\/strong\u003e 345\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52058076447089,"sku":"NNC350MVEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/60_0b2e69fe-1bd7-437a-a908-96cd120a9ac8.png?v=1763020042"},{"product_id":"400-mcm-3c-aluminum-mv-90-non-shielded-epr-insulated-pvc-jacketed-2-4-kv","title":"400 MCM 3C Aluminum MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/ilovepdf_merged_2.pdf?v=1735636134\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e400 MCM 3C Aluminum MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Per NEC, use is limited to 2400 volts maximum\u003cbr\u003e• For use in power system in industrial establishments and utility applications, for dry locations, in accordance with NEC.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e400 MCM Aluminum MV-90 Cable, 400 MCM 3C 2.4kV Non-Shielded Cable, 400 MCM  EPR Insulated PVC Cable, 400 MCM Medium Voltage 3C Aluminum, 400 MCM 2.4 kV EPR Cable, 400 MCM  Non-Shielded PVC Jacketed Cable, 400 MCM  3 Conductor MV-90 Cable, 400 MCM Aluminum EPR Cable 2.4 kV, 400 MCM MV-90 3C PVC Cable, 400 MCM  2.4 kV Aluminum Non-Shielded Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• UL 1072\u003cbr\u003e• Medium Voltage Power Cables.\u003cbr\u003e• ICEA S-96-659\/NEMA WC71\u003cbr\u003e• Standard for Nonshielded Cables Rated 2001-5000 Volts for Use in the Distribution of Electrical Energy.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• UL Listed as MV-90.\u003cbr\u003e• Rated For CT use 1\/0 AWG and up.\u003cbr\u003e• Jacket is listed Sunlight Resistant and Oil Resistant I.\u003cbr\u003e• Jacket is flame retardant.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e hard drawn Aluminum-1350 compacted Class B per ASTM B400.(6 AWG Aluminum) up to 1000 kcmil.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermoplastic polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 400 MCM \u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 37\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.66\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Insulation Thickness (mil):\u003c\/strong\u003e 90\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG :\u003c\/strong\u003e 1\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 2.18\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 2565\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52058152075633,"sku":"NNC400MVEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/60_0b2e69fe-1bd7-437a-a908-96cd120a9ac8.png?v=1763020042"},{"product_id":"500-mcm-3c-aluminum-mv-90-non-shielded-epr-insulated-pvc-jacketed-2-4-kv","title":"500 MCM 3C Aluminum MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/ilovepdf_merged_2.pdf?v=1735636134\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e500 MCM 3C Aluminum MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Per NEC, use is limited to 2400 volts maximum\u003cbr\u003e• For use in power system in industrial establishments and utility applications, for dry locations, in accordance with NEC.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e500 MCM Aluminum MV-90 Cable, 500 MCM 3C 2.4kV Non-Shielded Cable, 500 MCM  EPR Insulated PVC Cable, 500 MCM Medium Voltage 3C Aluminum, 500 MCM 2.4 kV EPR Cable, 500 MCM  Non-Shielded PVC Jacketed Cable, 500 MCM  3 Conductor MV-90 Cable, 500 MCM Aluminum EPR Cable 2.4 kV, 500 MCM MV-90 3C PVC Cable, 500 MCM  2.4 kV Aluminum Non-Shielded Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• UL 1072\u003cbr\u003e• Medium Voltage Power Cables.\u003cbr\u003e• ICEA S-96-659\/NEMA WC71\u003cbr\u003e• Standard for Nonshielded Cables Rated 2001-5000 Volts for Use in the Distribution of Electrical Energy.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• UL Listed as MV-90.\u003cbr\u003e• Rated For CT use 1\/0 AWG and up.\u003cbr\u003e• Jacket is listed Sunlight Resistant and Oil Resistant I.\u003cbr\u003e• Jacket is flame retardant.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e hard drawn Aluminum-1350 compacted Class B per ASTM B400.(6 AWG Aluminum) up to 1000 kcmil.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermoplastic polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 500 MCM \u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 37\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.74\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Insulation Thickness (mil):\u003c\/strong\u003e 90\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG :\u003c\/strong\u003e 1\/0\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 2.34\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 2986\u003cbr\u003e• \u003cstrong\u003eAmpacity 90 °C:\u003c\/strong\u003e 420\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52058152468849,"sku":"NNC500MVEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/60_0b2e69fe-1bd7-437a-a908-96cd120a9ac8.png?v=1763020042"},{"product_id":"600-mcm-3c-aluminum-mv-90-non-shielded-epr-insulated-pvc-jacketed-2-4-kv","title":"600 MCM 3C Aluminum MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/ilovepdf_merged_2.pdf?v=1735636134\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e600 MCM 3C Aluminum MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Per NEC, use is limited to 2400 volts maximum\u003cbr\u003e• For use in power system in industrial establishments and utility applications, for dry locations, in accordance with NEC.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e600 MCM Aluminum MV-90 Cable, 600 MCM 3C 2.4kV Non-Shielded Cable, 600 MCM  EPR Insulated PVC Cable, 600 MCM Medium Voltage 3C Aluminum, 600 MCM 2.4 kV EPR Cable, 600 MCM  Non-Shielded PVC Jacketed Cable, 600 MCM  3 Conductor MV-90 Cable, 600 MCM Aluminum EPR Cable 2.4 kV, 600 MCM MV-90 3C PVC Cable, 600 MCM  2.4 kV Aluminum Non-Shielded Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• UL 1072\u003cbr\u003e• Medium Voltage Power Cables.\u003cbr\u003e• ICEA S-96-659\/NEMA WC71\u003cbr\u003e• Standard for Nonshielded Cables Rated 2001-5000 Volts for Use in the Distribution of Electrical Energy.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• UL Listed as MV-90.\u003cbr\u003e• Rated For CT use 1\/0 AWG and up.\u003cbr\u003e• Jacket is listed Sunlight Resistant and Oil Resistant I.\u003cbr\u003e• Jacket is flame retardant.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e hard drawn Aluminum-1350 compacted Class B per ASTM B400.(6 AWG Aluminum) up to 1000 kcmil.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermoplastic polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 600 MCM \u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 61\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.81\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Insulation Thickness (mil):\u003c\/strong\u003e 90\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG :\u003c\/strong\u003e 1\/0\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 2.53\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 3427\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52058152665457,"sku":"NNC600MVEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/60_0b2e69fe-1bd7-437a-a908-96cd120a9ac8.png?v=1763020042"},{"product_id":"750-mcm-3c-aluminum-mv-90-non-shielded-epr-insulated-pvc-jacketed-2-4-kv","title":"750 MCM 3C Aluminum MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/ilovepdf_merged_2.pdf?v=1735636134\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e750 MCM 3C Aluminum MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Per NEC, use is limited to 2400 volts maximum\u003cbr\u003e• For use in power system in industrial establishments and utility applications, for dry locations, in accordance with NEC.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e750 MCM Aluminum MV-90 Cable, 750 MCM 3C 2.4kV Non-Shielded Cable, 750 MCM  EPR Insulated PVC Cable, 750 MCM Medium Voltage 3C Aluminum, 750 MCM 2.4 kV EPR Cable, 750 MCM  Non-Shielded PVC Jacketed Cable, 750 MCM  3 Conductor MV-90 Cable, 750 MCM Aluminum EPR Cable 2.4 kV, 750 MCM MV-90 3C PVC Cable, 750 MCM  2.4 kV Aluminum Non-Shielded Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• UL 1072\u003cbr\u003e• Medium Voltage Power Cables.\u003cbr\u003e• ICEA S-96-659\/NEMA WC71\u003cbr\u003e• Standard for Nonshielded Cables Rated 2001-5000 Volts for Use in the Distribution of Electrical Energy.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• UL Listed as MV-90.\u003cbr\u003e• Rated For CT use 1\/0 AWG and up.\u003cbr\u003e• Jacket is listed Sunlight Resistant and Oil Resistant I.\u003cbr\u003e• Jacket is flame retardant.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e hard drawn Aluminum-1350 compacted Class B per ASTM B400.(6 AWG Aluminum) up to 1000 kcmil.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermoplastic polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 750 MCM \u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 61\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.91 \u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Insulation Thickness (mil):\u003c\/strong\u003e 90\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG :\u003c\/strong\u003e 2\/0\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 140\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 2.80\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 4190\u003cbr\u003e• \u003cstrong\u003eAmpacity 90 °C:\u003c\/strong\u003e 520\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52058152993137,"sku":"NNC750MVEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/60_0b2e69fe-1bd7-437a-a908-96cd120a9ac8.png?v=1763020042"},{"product_id":"1000-mcm-3c-aluminum-mv-90-non-shielded-epr-insulated-pvc-jacketed-2-4-kv","title":"1000 MCM 3C Aluminum MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/ilovepdf_merged_2.pdf?v=1735636134\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1000 MCM 3C Aluminum MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Per NEC, use is limited to 2400 volts maximum\u003cbr\u003e• For use in power system in industrial establishments and utility applications, for dry locations, in accordance with NEC.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1000 MCM Aluminum MV-90 Cable, 1000 MCM 3C 2.4kV Non-Shielded Cable, 1000 MCM  EPR Insulated PVC Cable, 1000 MCM Medium Voltage 3C Aluminum, 1000 MCM 2.4 kV EPR Cable, 1000 MCM  Non-Shielded PVC Jacketed Cable, 1000 MCM  3 Conductor MV-90 Cable, 1000 MCM Aluminum EPR Cable 2.4 kV, 1000 MCM MV-90 3C PVC Cable, 1000 MCM  2.4 kV Aluminum Non-Shielded Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• UL 1072\u003cbr\u003e• Medium Voltage Power Cables.\u003cbr\u003e• ICEA S-96-659\/NEMA WC71\u003cbr\u003e• Standard for Nonshielded Cables Rated 2001-5000 Volts for Use in the Distribution of Electrical Energy.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• UL Listed as MV-90.\u003cbr\u003e• Rated For CT use 1\/0 AWG and up.\u003cbr\u003e• Jacket is listed Sunlight Resistant and Oil Resistant I.\u003cbr\u003e• Jacket is flame retardant.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e hard drawn Aluminum-1350 compacted Class B per ASTM B400.(6 AWG Aluminum) up to 1000 kcmil.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermoplastic polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1000 MCM \u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 61\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 1.06\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Insulation Thickness (mil):\u003c\/strong\u003e 90\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG :\u003c\/strong\u003e 2\/0\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 140\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 3.13\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 5271\u003cbr\u003e• \u003cstrong\u003eAmpacity 90 °C:\u003c\/strong\u003e 600\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52058153353585,"sku":"NNC1000MVEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/60_0b2e69fe-1bd7-437a-a908-96cd120a9ac8.png?v=1763020042"}],"url":"https:\/\/nassaunationalcable.com\/en-ca\/collections\/aluminum-3c-mv-90-non-shielded-epr-insulated-pvc-jacketed-2-4-kv.oembed?page=2","provider":"NassauNationalCable","version":"1.0","type":"link"}