2-2-2-4 Dyke Quadruplex Aluminum Conductor Underground Direct Burial 600V URD
Allowable Ampacity for 2-2-2-4 Dyke Quadruplex Aluminum Conductor 600V URD direct burial: 155 Amps
Allowable Ampacity for 2-2-2-4 Dyke Quadruplex Aluminum Conductor 600V URD in duct: 115 Amps
Applications:
The 2-2-2-4 Dyke Quadruplex Aluminum URD Cable is designed for low-load secondary distribution in underground electrical systems. It is 600V-rated and suitable for direct burial or installation in ducts. With aluminum conductors and XLPE insulation, this cable is moisture-resistant, heat-resistant, and durable for outdoor use.
With a maximum operating temperature of 90°C, it performs reliably in both wet and dry environments.
Also Known As:
2-2-2-4 dyke aluminum URD cable, 2-2-2-4 dyke URD direct burial cable, 2-2-2-4 dyke quadruplex cable, 2-2-2-4 dyke quadruplex wire, 2-2-2-4 dyke four-conductor wire, 2-2-2-4 dyke four-conductor cable, 2-2-2-4 dyke direct burial electrical cable, 2-2-2-4 dyke direct burial power cable, 2-2-2-4 dyke aluminum direct burial cable, 2 2 2 4 aluminum wire, 2-2-2-4 aluminum wire, 2 2 2 4 aluminum wire direct burial
Specific Use Cases of 2-2-2-4 URD
This cable supports low-load three-phase secondary distribution, delivering 2 AWG conductors with a 4 AWG neutral for residential, utility, and light commercial use.
- It powers service meters in residential subdivisions and rural distribution networks.
- It supplies underground power to light commercial buildings and municipal facilities.
- It provides electricity to single-family homes and small multi-unit residences.
- It is used in underground vaults and secondary power panels.
- It connects small-scale renewable energy systems to the grid.
- It supports temporary power setups for construction sites and backup systems.
Standards:
-
ASTM B-230
-
ASTM B-231
-
ASTM B-609
-
ASTM B-901
-
ICEA S-105-692
-
Federal Specification J-C – 30B
-
RUS ACCEPTED
Construction
Conductors:
Aluminum conductor used for this cable is either a concentric strand or compressed 1350-H19 series aluminum conductor. The conductors are cabled together, with surface printing for identification. The neutral conductor has a yellow stripe.
Insulation:
Versatile insulation system made of cross-linked black polyethylene material helps to secure the cable conductors. This insulation is water-tight, repulsive to corrosive substances, resistant to oil, heat, and flame. Cross-linking polyethylene helps to achieve an excellent strength that makes the material suitable for covering this cable used in harsh conditions like direct burial installation.
Specifications:
-
Size AWG: 2
-
Stranding: 7
-
Insulation Thickness (mils): 60
-
Neutral Size AWG: 4
-
Single Phase Conductor Inches: 0.403
-
O.D. Inches: 0.973
-
Weight lbs./1000ft: 367 lbs
-
Ampacity: Direct burial: 155 Amps
-
Ampacity: In duct: 115 Amps
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Download PDF Spec Sheet
Reviews
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460