{"title":"1000 Volts Wire and Cables","description":"","products":[{"product_id":"rwua-90-aluminum","title":"RWUA 90 CANADIAN ALUMINUM BUILDING WIRE 1kV","description":"\u003ch2\u003eRWUA 90 Canadian Aluminum Building Wire 1kv\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eRWUA 90 Canadian Aluminum building \u003cspan data-mce-fragment=\"1\"\u003eelectrical \u003c\/span\u003ewire is designed for use as a service entrance \u003cspan data-mce-fragment=\"1\"\u003eelectrical \u003c\/span\u003ecable above or below ground. Because of its sunlight and weather-resistant insulation, it can be used as exposed wiring. The wire is suitable for direct burial if the appropriate protection is installed. This building wire's temperature range is between -40 C and 90 C. The voltage rate is 1000 volts.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eRWUA 90 Canadian Aluminum Construction Wire 1kV, RWUA 90 Wire, RWUA 90 Cable, RWUA 90, \u003cmeta charset=\"utf-8\"\u003e \u003cspan data-mce-fragment=\"1\"\u003eRWUA 90 Service Entrance Cable\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eCSA Spec C22.2 No. 38-05\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eConductors:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe cable has a single compact ACM aluminum low-temperature conductor.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eAn extra cross-linked polyethylene (XLPE) insulation is resistant to moisture.\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cstrong\u003eFeatures:\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSingle compact ACM aluminum conductor with extra thickness of low temperature moisture resisting cross-linked polyethylene (XLPE) insulation\u003cbr\u003eCSA Spec C22.2 No. 38-05 \u003cbr\u003eRated 1000 volts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaximum conductor temperature 90°C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMinimum recommended installation temperature minus 40°C (with suitable handling procedures).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eService entrance above or below ground\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExposed wiring where exposed to weather with sunlight resistant insulation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27488072237156,"sku":"NNC3893X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/27.png?v=1759804697"},{"product_id":"4-rwua-90-aluminum","title":"4 RWUA 90 CANADIAN ALUMINUM BUILDING WIRE 1kV","description":"\u003ch2\u003e4 RWUA 90 Canadian Aluminum Building Wire 1kv\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003efor \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e4 RWUA 90 Canadian Aluminum Building Wire 1kv\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e: \u003cstrong\u003e105 Amps\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eRWUA 90 Canadian Aluminum building \u003cspan data-mce-fragment=\"1\"\u003eelectrical \u003c\/span\u003ewire is designed for use as a service entrance cable above or below ground. Because of its sunlight and weather-resistant insulation, it can be used as exposed wiring. The \u003cspan data-mce-fragment=\"1\"\u003eelectrical \u003c\/span\u003ewire is suitable for direct burial if the appropriate protection is installed. This building wire's temperature range is between -40 C and 90 C. The voltage rate is 1000 volts.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e4 RWUA 90 Canadian Aluminum Construction Wire 1kV, 4 RWUA 90 Wire, 4 RWUA 90 Cable, 4 RWUA 90, 4 RWUA 90 Service Entrance Cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eCSA Spec C22.2 No. 38-05\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eConductors:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe cable has a single compact ACM aluminum low-temperature conductor.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eAn extra cross-linked polyethylene (XLPE) insulation is resistant to moisture.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize AWG: \u003c\/strong\u003e4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight: \u003c\/strong\u003e72 lbs per 1000 ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverall Diameter: \u003c\/strong\u003e0.38 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation: \u003c\/strong\u003eXLPE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003cbr\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSingle compact ACM aluminum conductor with extra thickness of low temperature moisture resisting cross-linked polyethylene (XLPE) insulation\u003cbr\u003eCSA Spec C22.2 No. 38-05 \u003cbr\u003eRated 1000 volts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaximum conductor temperature 90°C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMinimum recommended installation temperature minus 40°C (with suitable handling procedures).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eService entrance above or below ground\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExposed wiring where exposed to weather with sunlight resistant insulation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27488072400996,"sku":"NNC3894X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/27_8efc64d2-c369-416c-ab97-e17e901167cb.png?v=1762459086"},{"product_id":"2-rwua-90-aluminum","title":"2 RWUA 90 CANADIAN ALUMINUM BUILDING WIRE 1kV","description":"\u003ch2\u003e2 RWUA 90 Canadian Aluminum Building Wire 1kv\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003efor \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e2 RWUA 90 Canadian Aluminum Building Wire 1kv\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e: \u003cstrong\u003e140 Amps\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eRWUA 90 Canadian Aluminum building \u003cspan data-mce-fragment=\"1\"\u003eelectrical \u003c\/span\u003ewire is designed for use as a service entrance cable above or below ground. Because of its sunlight and weather-resistant insulation, it can be used as exposed wiring. The \u003cspan data-mce-fragment=\"1\"\u003eelectrical \u003c\/span\u003ewire is suitable for direct burial if the appropriate protection is installed. This building wire's temperature range is between -40 C and 90 C. The voltage rate is 1000 volts.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eRWUA 90 Canadian Aluminum Construction Wire 1kV, RWUA 90 Wire, RWUA 90 Cable, RWUA 90, RWUA 90 Service Entrance Cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eCSA Spec C22.2 No. 38-05\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eConductors:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe cable has a single compact ACM aluminum low-temperature conductor.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eAn extra cross-linked polyethylene (XLPE) insulation is resistant to moisture.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize AWG: \u003c\/strong\u003e2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight: \u003c\/strong\u003e103 lbs per 1000 ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverall Diameter: \u003c\/strong\u003e0.43 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation: \u003c\/strong\u003eRW90 XLPE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cstrong\u003eFeatures:\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSingle compact ACM aluminum conductor with extra thickness of low temperature moisture resisting cross-linked polyethylene (XLPE) insulation\u003cbr\u003eCSA Spec C22.2 No. 38-05 \u003cbr\u003eRated 1000 volts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaximum conductor temperature 90°C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMinimum recommended installation temperature minus 40°C (with suitable handling procedures).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eService entrance above or below ground\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExposed wiring where exposed to weather with sunlight resistant insulation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27488072564836,"sku":"NNC3895X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/27_42de11fa-9318-40e8-8994-017d42495c75.png?v=1759804697"},{"product_id":"1-1-rwua-90-aluminum","title":"1\/1 RWUA 90 CANADIAN ALUMINUM BUILDING WIRE 1kV","description":"\u003ch2\u003e1\/1 RWUA 90 Canadian Aluminum Building Wire 1kv\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003efor \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e1\/1 RWUA 90 Canadian Aluminum Building Wire 1kv\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e: \u003cstrong\u003e190 Amps\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eRWUA 90 Canadian Aluminum building wire is designed for use as a service entrance cable above or below ground. Because of its sunlight and weather-resistant insulation, it can be used as exposed wiring. The wire is suitable for direct burial if the appropriate protection is installed. This building wire's temperature range is between -40 C and 90 C. The voltage rate is 1000 volts.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eRWUA 90 Canadian Aluminum Construction Wire 1kV, RWUA 90 Wire, RWUA 90 Cable, RWUA 90, RWUA 90 Service Entrance Cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eCSA Spec C22.2 No. 38-05\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eConductors:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe cable has a single compact ACM aluminum low-temperature conductor.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eAn extra cross-linked polyethylene (XLPE) insulation is resistant to moisture.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize AWG: \u003c\/strong\u003e1\/1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight: \u003c\/strong\u003e157 lbs per 1000 ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverall Diameter: \u003c\/strong\u003e0.53 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation: \u003c\/strong\u003eRW90 XLPE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cstrong\u003eFeatures:\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSingle compact ACM aluminum conductor with extra thickness of low temperature moisture resisting cross-linked polyethylene (XLPE) insulation\u003cbr\u003eCSA Spec C22.2 No. 38-05 \u003cbr\u003eRated 1000 volts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaximum conductor temperature 90°C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMinimum recommended installation temperature minus 40°C (with suitable handling procedures).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eService entrance above or below ground\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExposed wiring where exposed to weather with sunlight resistant insulation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cgdiv\u003e\u003c\/gdiv\u003e\u003ciframe class=\"ginger-extension-definitionpopup\" style=\"display: none;\"\u003e\u003c\/iframe\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e","brand":"Nassau National cable","offers":[{"title":"Default Title","offer_id":27488072695908,"sku":"NNC3896X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/27_4a86ccaa-cae4-4330-a9a6-5b805b36033b.png?v=1762459086"},{"product_id":"4-0-rwua-90-aluminum","title":"4\/0 RWUA 90 CANADIAN ALUMINUM BUILDING WIRE 1kV","description":"\u003ch2\u003e4\/0 RWUA 90 Canadian Aluminum Building Wire 1kv\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003efor \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e4\/0 RWUA 90 Canadian Aluminum Building Wire 1kv\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e: \u003cstrong\u003e300 Amps\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eRWUA 90 Canadian Aluminum building wire is designed for use as a service entrance cable above or below ground. Because of its sunlight and weather-resistant insulation, it can be used as exposed wiring. The wire is suitable for direct burial if the appropriate protection is installed. This building wire's temperature range is between -40 C and 90 C. The voltage rate is 1000 volts.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eRWUA 90 Canadian Aluminum Construction Wire 1kV, RWUA 90 Wire, RWUA 90 Cable, RWUA 90, RWUA 90 Service Entrance Cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eCSA Spec C22.2 No. 38-05\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eConductors:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe cable has a single compact ACM aluminum low-temperature conductor.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eAn extra cross-linked polyethylene (XLPE) insulation is resistant to moisture.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize AWG:\u003c\/strong\u003e 4\/0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight: \u003c\/strong\u003e275 lbs per 1000 ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverall Diameter: \u003c\/strong\u003e0.67 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation: \u003c\/strong\u003eRW90 XLPE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eFeatures:\u003cbr\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSingle compact ACM aluminum conductor with extra thickness of low temperature moisture resisting cross-linked polyethylene (XLPE) insulation\u003cbr\u003eCSA Spec C22.2 No. 38-05 \u003cbr\u003eRated 1000 volts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaximum conductor temperature 90°C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMinimum recommended installation temperature minus 40°C (with suitable handling procedures).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eService entrance above or below ground\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExposed wiring where exposed to weather with sunlight resistant insulation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27488072826980,"sku":"NNC3897X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/27_1793c724-3116-4345-a79c-1dbcae38cb43.png?v=1762459087"},{"product_id":"250-rwua-90-aluminum","title":"250 RWUA 90 CANADIAN ALUMINUM BUILDING WIRE 1kV","description":"\u003ch2\u003e250 RWUA 90 Canadian Aluminum Building Wire 1kv\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003efor \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e250RWUA 90 Canadian Aluminum Building Wire 1kv\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e: \u003cstrong\u003e330 Amps\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eRWUA 90 Canadian Aluminum building \u003cspan data-mce-fragment=\"1\"\u003eelectrical \u003c\/span\u003ewire is designed for use as a service entrance cable above or below ground. Because of its sunlight and weather-resistant insulation, it can be used as exposed wiring. The \u003cspan data-mce-fragment=\"1\"\u003eelectrical \u003c\/span\u003ewire is suitable for direct burial if the appropriate protection is installed. This building wire's temperature range is between -40 C and 90 C. The voltage rate is 1000 volts.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eRWUA 90 Canadian Aluminum Construction Wire 1kV, RWUA 90 Wire, RWUA 90 Cable, RWUA 90, RWUA 90 Service Entrance Cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eCSA Spec C22.2 No. 38-05\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eConductors:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe cable has a single compact ACM aluminum low-temperature conductor.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eAn extra cross-linked polyethylene (XLPE) insulation is resistant to moisture.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize AWG: \u003c\/strong\u003e250\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight: \u003c\/strong\u003e331 lbs per 1000 ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverall Diameter: \u003c\/strong\u003e0.79 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation:\u003c\/strong\u003e RW90 XLPE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSingle compact ACM aluminum conductor with extra thickness of low temperature moisture resisting cross-linked polyethylene (XLPE) insulation\u003cbr\u003eCSA Spec C22.2 No. 38-05 \u003cbr\u003eRated 1000 volts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaximum conductor temperature 90°C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMinimum recommended installation temperature minus 40°C (with suitable handling procedures).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eService entrance above or below ground\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExposed wiring where exposed to weather with sunlight resistant insulation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27488073023588,"sku":"NNC3898X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/27_91be0e90-0c24-4764-aac4-a0b0c62444aa.png?v=1762459087"},{"product_id":"350-rwua-90-aluminum","title":"350 RWUA 90 CANADIAN ALUMINUM BUILDING WIRE 1kV","description":"\u003ch2\u003e350 RWUA 90 Canadian Aluminum Building Wire 1kv\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003efor \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e350 RWUA 90 Canadian Aluminum Building Wire 1kv\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e: \u003cstrong\u003e415 Amps\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eRWUA 90 Canadian Aluminum building \u003cspan data-mce-fragment=\"1\"\u003eelectrical \u003c\/span\u003ewire is designed for use as a service entrance cable above or below ground. Because of its sunlight and weather-resistant insulation, it can be used as exposed wiring. The \u003cspan data-mce-fragment=\"1\"\u003eelectrical \u003c\/span\u003ewire is suitable for direct burial if the appropriate protection is installed. This building wire's temperature range is between -40 C and 90 C. The voltage rate is 1000 volts.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eRWUA 90 Canadian Aluminum Construction Wire 1kV, RWUA 90 Wire, RWUA 90 Cable, RWUA 90, RWUA 90 Service Entrance Cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eCSA Spec C22.2 No. 38-05\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eConductors:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe cable has a single compact ACM aluminum low-temperature conductor.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eAn extra cross-linked polyethylene (XLPE) insulation is resistant to moisture.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize AWG: \u003c\/strong\u003e350\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight: \u003c\/strong\u003e443 lbs per 1000 ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverall Diameter: \u003c\/strong\u003e0.84 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation: \u003c\/strong\u003eRW90 XLPE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSingle compact ACM aluminum conductor with extra thickness of low temperature moisture resisting cross-linked polyethylene (XLPE) insulation\u003cbr\u003eCSA Spec C22.2 No. 38-05 \u003cbr\u003eRated 1000 volts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaximum conductor temperature 90°C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMinimum recommended installation temperature minus 40°C (with suitable handling procedures).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eService entrance above or below ground\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExposed wiring where exposed to weather with sunlight resistant insulation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cgdiv\u003e\u003c\/gdiv\u003e\u003ciframe style=\"display: none;\" class=\"ginger-extension-definitionpopup\"\u003e\u003c\/iframe\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27488073121892,"sku":"NNC3899X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/27_e304d610-fc1a-4022-9557-618f74152429.png?v=1762459088"},{"product_id":"500-rwua-90-aluminum","title":"500 RWUA 90 CANADIAN ALUMINUM BUILDING WIRE 1kV","description":"[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/ACWU_CABLE.pdf?v=1627366077\" width=\"\" height=\"\" type=\"application\/pdf\"\u003e [\/pdf]\n\u003ch2\u003e500 RWUA 90 Canadian Aluminum Building Wire 1kv\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003efor \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003e500 RWUA 90 Canadian Aluminum Building Wire 1kv\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003e: \u003cstrong\u003e515 Amps\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003eRWUA 90 Canadian Aluminum building \u003cspan data-mce-fragment=\"1\"\u003eelectrical \u003c\/span\u003ewire is designed for use as a service entrance cable above or below ground. Because of its sunlight and weather-resistant insulation, it can be used as exposed wiring. The \u003cspan data-mce-fragment=\"1\"\u003eelectrical \u003c\/span\u003ewire is suitable for direct burial if the appropriate protection is installed. This building wire's temperature range is between -40 C and 90 C. The voltage rate is 1000 volts.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eRWUA 90 Canadian Aluminum Construction Wire 1kV, RWUA 90 Wire, RWUA 90 Cable, RWUA 90, RWUA 90 Service Entrance Cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003eCSA Spec C22.2 No. 38-05\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eConductors:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003eThe cable has a single compact ACM aluminum low-temperature conductor.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003eAn extra cross-linked polyethylene (XLPE) insulation is resistant to moisture.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize AWG:\u003c\/strong\u003e 500\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight: \u003c\/strong\u003e609 lbs per 1000 ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverall Diameter: \u003c\/strong\u003e0.96 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation: \u003c\/strong\u003eRW90 XLPE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSingle compact ACM aluminum conductor with extra thickness of low temperature moisture resisting cross-linked polyethylene (XLPE) insulation\u003cbr\u003eCSA Spec C22.2 No. 38-05 \u003cbr\u003eRated 1000 volts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaximum conductor temperature 90°C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMinimum recommended installation temperature minus 40°C (with suitable handling procedures).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eService entrance above or below ground\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExposed wiring where exposed to weather with sunlight resistant insulation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27488073285732,"sku":"NNC3900X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/27_42cfee3f-02d8-435d-bcc6-0ba744a0bf2a.png?v=1759804698"},{"product_id":"8-4-teck-90-bare-copper-aluminum-interlocked-armored-cable-with-ground-1kv","title":"8\/4 Teck 90 Bare Copper Aluminum Interlocked Armored Cable With Ground 1KV","description":"\u003cp\u003e[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Teck_90_AL_1kv.pdf?v=1742394179\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e8\/4 Teck 90 Bare Copper Aluminum Interlocked Armored Cable With Ground 1KV\u003c\/span\u003e \u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eFor exposed or concealed wiring in wet or dry locations. For use in ventilated, non ventilated and ladder type cable troughs and ventilated flexible cableway in wet, dry, or hazardous locations. Sunlight Resistant. Typical applications are for control. lighting and power circuits in: pulp and paper mills, steel mills, food processing plants, commercial centers, mines, generating stations, refineries, industrial plants and chemical plants. Rated for 1000 lbs.\/FT maximum sidewall pressure. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e8\/4 \u003cspan\u003eAWG \u003c\/span\u003eTeck 90 cable ,1KV armored cable, 8\/4 \u003cspan\u003eAWG \u003c\/span\u003eBare copper interlocked cable, Aluminum armored cable, Teck 90 1KV rating, 8\/4 \u003cspan\u003eAWG \u003c\/span\u003eInterlocked armored cable, Bare copper aluminum cable, 8\/4 \u003cspan\u003eAWG \u003c\/span\u003eArmored electrical cable.\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eClass B stranded copper, compressed or compact, in accordance with ASTM B3 and B8.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCross-Linked Polyethylene (XLPE), Colour Code: 2\/C black, white; 3\/C red, black, blue; 4\/C red, black, blue, white For cables larger than No. 2 AWG or more than 4\/C, the insulation is black and numbered\u003cbr\u003e\u003cstrong\u003e• Grounding Conductors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUninsulated Class B stranded grounding conductor\u003cbr\u003e\u003cstrong\u003e• Inner Jacket:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBlack Polyvinyl Chloride (PVC)\u003cbr\u003e\u003cstrong\u003e• Armor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAluminum Interlocked Armour (AIA)\u003cbr\u003e\u003cstrong\u003e• Overall Jacket:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBlack PVC (optional colours available)\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA C22.2 No. 174 Cables in Hazardous Locations\u003cbr\u003e• CSA C22.2 No. 131 Type TECK 90 Cable\u003cbr\u003e• CSA C22.2 No. 2556 \u0026amp; No. 0.3 Wire and Cable Test Methods\u003cbr\u003e• CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating\u003cbr\u003e• CSA HL - for Hazardous Locations rating\u003cbr\u003e• CSA SUN RES - for Sunlight Resistant rating\u003cbr\u003e• CSA AG14 - Acid Gas Compliance\u003cbr\u003e• IEEE 383 Flame Test (70,000 btu)\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1000V Multi Conductor, 8AWG -1000 Kcmil Copper, FT4 - Flame Retardancy Rating, XLPE Insulation, Aluminum Interlocked Armour, Sunlight Resistant, -40°C - 90°C, Rated HL, AG14\u003cbr\u003e\u003cbr\u003e•  -40°C - CSA Cold Bend and Impact Temperature\u003cbr\u003e• -25°C - Min. Installation Temperature\u003cbr\u003e• 90°C - Max. Continuous Operating Temperature\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e8 AWG\u003cbr\u003e\u003cstrong\u003e• No of conductor: \u003c\/strong\u003e4\u003cbr\u003e\u003cstrong\u003e• No of Strands: \u003c\/strong\u003e7\u003cbr\u003e\u003cstrong\u003e• Insulation thickness ( mil ): \u003c\/strong\u003e45\u003cbr\u003e\u003cstrong\u003e• Ground No x AWG:\u003c\/strong\u003e 1x10\u003cbr\u003e\u003cstrong\u003e• Inner Jacket thickness ( mil ): \u003c\/strong\u003e65\u003cbr\u003e\u003cstrong\u003e• Dia. Over Armour ( Inch ):\u003c\/strong\u003e  0.905\u003cbr\u003e\u003cstrong\u003e• Overall Jacket thickness ( mil ): \u003c\/strong\u003e55\u003cbr\u003e\u003cstrong\u003e• Approx. OD ( Inch ):  \u003c\/strong\u003e1.015\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (lb\/1000ft): \u003c\/strong\u003e578\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity In Raceway 90°C†: \u003c\/strong\u003e44 Amp\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 385px; height: 202px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 375px; height: 35.5938px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cspan\u003eCompatible with Manufacturer\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"height: 19.5938px; width: 184.094px;\"\u003e\u003cstrong\u003eGeneral Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px; width: 184.906px;\"\u003e\n\u003cstrong\u003eBlack :\u003c\/strong\u003e 331250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"height: 19.5938px; width: 184.094px;\"\u003e\u003cstrong\u003eNexans :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px; width: 184.906px;\"\u003e\n\u003cstrong\u003eBlack :\u003c\/strong\u003e 383612\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"height: 19.5938px; width: 184.094px;\"\u003e\u003cstrong\u003eOmni Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px; width: 184.906px;\"\u003e\n\u003cstrong\u003eBlack :\u003c\/strong\u003e T30804\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"height: 19.5938px; width: 184.094px;\"\u003e\u003cstrong\u003eSouthwire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px; width: 184.906px;\"\u003e\n\u003cstrong\u003eBlack :\u003c\/strong\u003e 561964\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 184.094px;\"\u003e\u003cstrong\u003eService Wire Co :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 184.906px;\"\u003e\n\u003cstrong\u003eBlack : \u003c\/strong\u003eCAAC8\/4U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 184.094px;\"\u003e\u003cstrong\u003eHouston Wire \u0026amp; Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 184.906px;\"\u003e\n\u003cstrong\u003eBlack : \u003c\/strong\u003eHW331 00804\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27488105037924,"sku":"NNC3992X","price":6.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/teck90_3390b4b9-7c09-4e00-8fa8-72f5cde1bbcd.png?v=1762459141"},{"product_id":"6-2-teck-90-bare-copper-aluminum-interlocked-armored-cable-with-ground-1kv","title":"6\/2 Teck 90 Bare Copper Aluminum Interlocked Armored Cable With Ground 1KV","description":"\u003cp\u003e[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Teck_90_AL_1kv.pdf?v=1742394179\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e6\/2 Teck 90 Bare Copper Aluminum Interlocked Armored Cable With Ground 1KV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eFor exposed or concealed wiring in wet or dry locations. For use in ventilated, non ventilated and ladder type cable troughs and ventilated flexible cableway in wet, dry, or hazardous locations. Sunlight Resistant. Typical applications are for control. lighting and power circuits in: pulp and paper mills, steel mills, food processing plants, commercial centers, mines, generating stations, refineries, industrial plants and chemical plants. Rated for 1000 lbs.\/FT maximum sidewall pressure. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e6\/2\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eAWG \u003c\/span\u003eTeck 90 cable ,1KV armored cable, 6\/2\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eAWG \u003c\/span\u003eBare copper interlocked cable, Aluminum armored cable, Teck 90 1KV rating, 6\/2\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eAWG \u003c\/span\u003eInterlocked armored cable, Bare copper aluminum cable, 6\/2\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eAWG \u003c\/span\u003eArmored electrical cable.\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eClass B stranded copper, compressed or compact, in accordance with ASTM B3 and B8.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCross-Linked Polyethylene (XLPE), Colour Code: 2\/C black, white; 3\/C red, black, blue; 4\/C red, black, blue, white For cables larger than No. 2 AWG or more than 4\/C, the insulation is black and numbered\u003cbr\u003e\u003cstrong\u003e• Grounding Conductors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUninsulated Class B stranded grounding conductor\u003cbr\u003e\u003cstrong\u003e• Inner Jacket:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBlack Polyvinyl Chloride (PVC)\u003cbr\u003e\u003cstrong\u003e• Armor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAluminum Interlocked Armour (AIA)\u003cbr\u003e\u003cstrong\u003e• Overall Jacket:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBlack PVC (optional colours available)\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA C22.2 No. 174 Cables in Hazardous Locations\u003cbr\u003e• CSA C22.2 No. 131 Type TECK 90 Cable\u003cbr\u003e• CSA C22.2 No. 2556 \u0026amp; No. 0.3 Wire and Cable Test Methods\u003cbr\u003e• CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating\u003cbr\u003e• CSA HL - for Hazardous Locations rating\u003cbr\u003e• CSA SUN RES - for Sunlight Resistant rating\u003cbr\u003e• CSA AG14 - Acid Gas Compliance\u003cbr\u003e• IEEE 383 Flame Test (70,000 btu)\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1000V Multi Conductor, 8AWG -1000 Kcmil Copper, FT4 - Flame Retardancy Rating, XLPE Insulation, Aluminum Interlocked Armour, Sunlight Resistant, -40°C - 90°C, Rated HL, AG14\u003cbr\u003e\u003cbr\u003e•  -40°C - CSA Cold Bend and Impact Temperature\u003cbr\u003e• -25°C - Min. Installation Temperature\u003cbr\u003e• 90°C - Max. Continuous Operating Temperature\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e6 AWG\u003cbr\u003e\u003cstrong\u003e• No of conductor: \u003c\/strong\u003e2\u003cbr\u003e\u003cstrong\u003e• No of Strands: \u003c\/strong\u003e7\u003cbr\u003e\u003cstrong\u003e• Insulation thickness ( mil ): \u003c\/strong\u003e60\u003cbr\u003e\u003cstrong\u003e• Ground No x AWG:\u003c\/strong\u003e 1 x 8\u003cbr\u003e\u003cstrong\u003e• Inner Jacket thickness ( mil ):\u003c\/strong\u003e 65\u003cbr\u003e\u003cstrong\u003e• Dia. Over Armour ( Inch ):\u003c\/strong\u003e 0.941\u003cbr\u003e\u003cstrong\u003e• Overall Jacket thickness ( mil ): \u003c\/strong\u003e45\u003cbr\u003e\u003cstrong\u003e• Approx. OD ( Inch ): \u003c\/strong\u003e1.031\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (lb\/1000ft):\u003c\/strong\u003e 537\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity In Raceway 90°C†: \u003c\/strong\u003e75 Amp\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27488105070692,"sku":"NNC3993X","price":7.48,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/teck90_a5e4a0ea-2fcb-4b25-8af8-53ba0ababc6c.png?v=1762459142"},{"product_id":"6-4-teck-90-bare-copper-aluminum-interlocked-armored-cable-with-ground-1kv","title":"6\/4 Teck 90 Bare Copper Aluminum Interlocked Armored Cable With Ground 1KV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Teck_90_AL_1kv.pdf?v=1742394179\" width=\"\" height=\"\" type=\"application\/pdf\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e6\/4 Teck 90 Bare Copper Aluminum Interlocked Armored Cable With Ground 1KV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eFor exposed or concealed wiring in wet or dry locations. For use in ventilated, non ventilated and ladder type cable troughs and ventilated flexible cableway in wet, dry, or hazardous locations. Sunlight Resistant. Typical applications are for control. lighting and power circuits in: pulp and paper mills, steel mills, food processing plants, commercial centers, mines, generating stations, refineries, industrial plants and chemical plants. Rated for 1000 lbs.\/FT maximum sidewall pressure. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e6\/4 \u003cspan\u003eAWG \u003c\/span\u003eTeck 90 cable ,1KV armored cable, 6\/4 \u003cspan\u003eAWG \u003c\/span\u003eBare copper interlocked cable, Aluminum armored cable, Teck 90 1KV rating, 6\/4 \u003cspan\u003eAWG \u003c\/span\u003eInterlocked armored cable, Bare copper aluminum cable, 6\/4 \u003cspan\u003eAWG \u003c\/span\u003eArmored electrical cable.\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eClass B stranded copper, compressed or compact, in accordance with ASTM B3 and B8.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCross-Linked Polyethylene (XLPE), Colour Code: 2\/C black, white; 3\/C red, black, blue; 4\/C red, black, blue, white For cables larger than No. 2 AWG or more than 4\/C, the insulation is black and numbered\u003cbr\u003e\u003cstrong\u003e• Grounding Conductors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUninsulated Class B stranded grounding conductor\u003cbr\u003e\u003cstrong\u003e• Inner Jacket:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBlack Polyvinyl Chloride (PVC)\u003cbr\u003e\u003cstrong\u003e• Armor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAluminum Interlocked Armour (AIA)\u003cbr\u003e\u003cstrong\u003e• Overall Jacket:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBlack PVC (optional colours available)\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA C22.2 No. 174 Cables in Hazardous Locations\u003cbr\u003e• CSA C22.2 No. 131 Type TECK 90 Cable\u003cbr\u003e• CSA C22.2 No. 2556 \u0026amp; No. 0.3 Wire and Cable Test Methods\u003cbr\u003e• CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating\u003cbr\u003e• CSA HL - for Hazardous Locations rating\u003cbr\u003e• CSA SUN RES - for Sunlight Resistant rating\u003cbr\u003e• CSA AG14 - Acid Gas Compliance\u003cbr\u003e• IEEE 383 Flame Test (70,000 btu)\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1000V Multi Conductor, 8AWG -1000 Kcmil Copper, FT4 - Flame Retardancy Rating, XLPE Insulation, Aluminum Interlocked Armour, Sunlight Resistant, -40°C - 90°C, Rated HL, AG14\u003cbr\u003e\u003cbr\u003e•  -40°C - CSA Cold Bend and Impact Temperature\u003cbr\u003e• -25°C - Min. Installation Temperature\u003cbr\u003e• 90°C - Max. Continuous Operating Temperature\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e6 AWG\u003cbr\u003e\u003cstrong\u003e• No of conductor: \u003c\/strong\u003e4\u003cbr\u003e\u003cstrong\u003e• No of Strands: \u003c\/strong\u003e7\u003cbr\u003e\u003cstrong\u003e• Insulation thickness ( mil ): \u003c\/strong\u003e60\u003cbr\u003e\u003cstrong\u003e• Ground No x AWG:\u003c\/strong\u003e 1 x 8\u003cbr\u003e\u003cstrong\u003e• Inner Jacket thickness ( mil ):\u003c\/strong\u003e 85\u003cbr\u003e\u003cstrong\u003e• Dia. Over Armour ( Inch ):\u003c\/strong\u003e 1.216\u003cbr\u003e\u003cstrong\u003e• Overall Jacket thickness ( mil ): \u003c\/strong\u003e45\u003cbr\u003e\u003cstrong\u003e• Approx. OD ( Inch ): \u003c\/strong\u003e1.306\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (lb\/1000ft): \u003c\/strong\u003e889\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity In Raceway 90°C†: \u003c\/strong\u003e60 Amp\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable height=\"181\" style=\"width: 352px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"width: 342px; height: 21px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cspan\u003eCompatible with Manufacturer\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 155.766px;\"\u003e\u003cstrong\u003eGeneral Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 180.234px;\"\u003e\n\u003cstrong\u003eBlack :\u003c\/strong\u003e 11288.0306\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 155.766px;\"\u003e\u003cstrong\u003eNexans :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 180.234px;\"\u003e\n\u003cstrong\u003eBlack :\u003c\/strong\u003e 383620\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 155.766px;\"\u003e\u003cstrong\u003eOmni Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 180.234px;\"\u003e\n\u003cstrong\u003eBlack :\u003c\/strong\u003e T30604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 155.766px;\"\u003e\u003cstrong\u003eSouthwire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 180.234px;\"\u003e\n\u003cstrong\u003eBlack :\u003c\/strong\u003e 561966\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 155.766px;\"\u003e\u003cstrong\u003eService Wire Co :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 180.234px;\"\u003e\n\u003cstrong\u003eBlack : \u003c\/strong\u003eCAAC6\/4U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 155.766px;\"\u003e\u003cstrong\u003eHouston Wire \u0026amp; Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 180.234px;\"\u003e\n\u003cstrong\u003eBlack : \u003c\/strong\u003eHW331 00604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27488105168996,"sku":"NNC3995X","price":10.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/teck90_df3f280f-a6af-4435-a727-c60ffb6e9a4b.png?v=1762459142"},{"product_id":"4-4-teck-90-bare-copper-aluminum-interlocked-armored-cable-with-ground-1kv","title":"4\/4 Teck 90 Bare Copper Aluminum Interlocked Armored Cable With Ground 1KV","description":"\u003cp\u003e[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Teck_90_AL_1kv.pdf?v=1742394179\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e4\/4 Teck 90 Bare Copper Aluminum Interlocked Armored Cable With Ground 1KV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eFor exposed or concealed wiring in wet or dry locations. For use in ventilated, non ventilated and ladder type cable troughs and ventilated flexible cableway in wet, dry, or hazardous locations. Sunlight Resistant. Typical applications are for control. lighting and power circuits in: pulp and paper mills, steel mills, food processing plants, commercial centers, mines, generating stations, refineries, industrial plants and chemical plants. Rated for 1000 lbs.\/FT maximum sidewall pressure. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e4\/4 \u003c\/span\u003e\u003cspan\u003eAWG \u003c\/span\u003eTeck 90 cable ,1KV armored cable, 4\/4\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eAWG \u003c\/span\u003eBare copper interlocked cable, Aluminum armored cable, Teck 90 1KV rating, 4\/4\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eAWG \u003c\/span\u003eInterlocked armored cable, Bare copper aluminum cable, 4\/4\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eAWG \u003c\/span\u003eArmored electrical cable.\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eClass B stranded copper, compressed or compact, in accordance with ASTM B3 and B8.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCross-Linked Polyethylene (XLPE), Colour Code: 2\/C black, white; 3\/C red, black, blue; 4\/C red, black, blue, white For cables larger than No. 2 AWG or more than 4\/C, the insulation is black and numbered\u003cbr\u003e\u003cstrong\u003e• Grounding Conductors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUninsulated Class B stranded grounding conductor\u003cbr\u003e\u003cstrong\u003e• Inner Jacket:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBlack Polyvinyl Chloride (PVC)\u003cbr\u003e\u003cstrong\u003e• Armor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAluminum Interlocked Armour (AIA)\u003cbr\u003e\u003cstrong\u003e• Overall Jacket:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBlack PVC (optional colours available)\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA C22.2 No. 174 Cables in Hazardous Locations\u003cbr\u003e• CSA C22.2 No. 131 Type TECK 90 Cable\u003cbr\u003e• CSA C22.2 No. 2556 \u0026amp; No. 0.3 Wire and Cable Test Methods\u003cbr\u003e• CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating\u003cbr\u003e• CSA HL - for Hazardous Locations rating\u003cbr\u003e• CSA SUN RES - for Sunlight Resistant rating\u003cbr\u003e• CSA AG14 - Acid Gas Compliance\u003cbr\u003e• IEEE 383 Flame Test (70,000 btu)\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1000V Multi Conductor, 8AWG -1000 Kcmil Copper, FT4 - Flame Retardancy Rating, XLPE Insulation, Aluminum Interlocked Armour, Sunlight Resistant, -40°C - 90°C, Rated HL, AG14\u003cbr\u003e\u003cbr\u003e•  -40°C - CSA Cold Bend and Impact Temperature\u003cbr\u003e• -25°C - Min. Installation Temperature\u003cbr\u003e• 90°C - Max. Continuous Operating Temperature\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e4 AWG\u003cbr\u003e\u003cstrong\u003e• No of conductor: \u003c\/strong\u003e4\u003cbr\u003e\u003cstrong\u003e• No of Strands: \u003c\/strong\u003e7\u003cbr\u003e\u003cstrong\u003e• Insulation thickness ( mil ): \u003c\/strong\u003e60\u003cbr\u003e\u003cstrong\u003e• Ground No x AWG:\u003c\/strong\u003e 1 x 8\u003cbr\u003e\u003cstrong\u003e• Inner Jacket thickness ( mil ):\u003c\/strong\u003e 85\u003cbr\u003e\u003cstrong\u003e• Dia. Over Armour ( Inch ):\u003c\/strong\u003e 1.330\u003cbr\u003e\u003cstrong\u003e• Overall Jacket thickness ( mil ): \u003c\/strong\u003e45\u003cbr\u003e\u003cstrong\u003e• Approx. OD ( Inch ): \u003c\/strong\u003e1.420\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (lb\/1000ft):\u003c\/strong\u003e 1150\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity In Raceway 90°C†: \u003c\/strong\u003e76 Amp\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable height=\"212\" style=\"width: 413px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"width: 403px; height: 21px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cspan\u003eCompatible with Manufacturer\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 186.266px;\"\u003e\u003cstrong\u003eGeneral Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 210.734px;\"\u003e\n\u003cstrong\u003eBlack :\u003c\/strong\u003e 11288.0204\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 186.266px;\"\u003e\u003cstrong\u003eNexans :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 210.734px;\"\u003e\n\u003cstrong\u003eBlack :\u003c\/strong\u003e 529271\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 186.266px;\"\u003e\u003cstrong\u003eOmni Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 210.734px;\"\u003e\n\u003cstrong\u003eBlack :\u003c\/strong\u003e T30404\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 186.266px;\"\u003e\u003cstrong\u003eSouthwire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 210.734px;\"\u003e\n\u003cstrong\u003eBlack :\u003c\/strong\u003e 561968\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 186.266px;\"\u003e\u003cstrong\u003eService Wire Co :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 210.734px;\"\u003e\n\u003cstrong\u003eBlack : \u003c\/strong\u003eCAAC4\/4U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 186.266px;\"\u003e\u003cstrong\u003eHouston Wire \u0026amp; Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 210.734px;\"\u003e\n\u003cstrong\u003eBlack : \u003c\/strong\u003eHW331 00404\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27488110215268,"sku":"NNC3997X","price":15.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/teck90_3aebd477-2ac7-4999-876f-f6d0757879b4.png?v=1762459144"},{"product_id":"4-2-teck-90-bare-copper-aluminum-interlocked-armored-cable-with-ground-1kv","title":"4\/2 Teck 90 Bare Copper Aluminum Interlocked Armored Cable With Ground 1KV","description":"\u003cp\u003e[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Teck_90_AL_1kv.pdf?v=1742394179\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e4\/2 Teck 90 Bare Copper Aluminum Interlocked Armored Cable With Ground 1KV\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eFor exposed or concealed wiring in wet or dry locations. For use in ventilated, non ventilated and ladder type cable troughs and ventilated flexible cableway in wet, dry, or hazardous locations. Sunlight Resistant. Typical applications are for control. lighting and power circuits in: pulp and paper mills, steel mills, food processing plants, commercial centers, mines, generating stations, refineries, industrial plants and chemical plants. Rated for 1000 lbs.\/FT maximum sidewall pressure. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e4\/2 \u003c\/span\u003e\u003cspan\u003eAWG \u003c\/span\u003eTeck 90 cable ,1KV armored cable, 4\/2\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eAWG \u003c\/span\u003eBare copper interlocked cable, Aluminum armored cable, Teck 90 1KV rating, 4\/2\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eAWG \u003c\/span\u003eInterlocked armored cable, Bare copper aluminum cable, 4\/2\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eAWG \u003c\/span\u003eArmored electrical cable.\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eClass B stranded copper, compressed or compact, in accordance with ASTM B3 and B8.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCross-Linked Polyethylene (XLPE), Colour Code: 2\/C black, white; 3\/C red, black, blue; 4\/C red, black, blue, white For cables larger than No. 2 AWG or more than 4\/C, the insulation is black and numbered\u003cbr\u003e\u003cstrong\u003e• Grounding Conductors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUninsulated Class B stranded grounding conductor\u003cbr\u003e\u003cstrong\u003e• Inner Jacket:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBlack Polyvinyl Chloride (PVC)\u003cbr\u003e\u003cstrong\u003e• Armor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAluminum Interlocked Armour (AIA)\u003cbr\u003e\u003cstrong\u003e• Overall Jacket:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBlack PVC (optional colours available)\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA C22.2 No. 174 Cables in Hazardous Locations\u003cbr\u003e• CSA C22.2 No. 131 Type TECK 90 Cable\u003cbr\u003e• CSA C22.2 No. 2556 \u0026amp; No. 0.3 Wire and Cable Test Methods\u003cbr\u003e• CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating\u003cbr\u003e• CSA HL - for Hazardous Locations rating\u003cbr\u003e• CSA SUN RES - for Sunlight Resistant rating\u003cbr\u003e• CSA AG14 - Acid Gas Compliance\u003cbr\u003e• IEEE 383 Flame Test (70,000 btu)\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1000V Multi Conductor, 8AWG -1000 Kcmil Copper, FT4 - Flame Retardancy Rating, XLPE Insulation, Aluminum Interlocked Armour, Sunlight Resistant, -40°C - 90°C, Rated HL, AG14\u003cbr\u003e\u003cbr\u003e•  -40°C - CSA Cold Bend and Impact Temperature\u003cbr\u003e• -25°C - Min. Installation Temperature\u003cbr\u003e• 90°C - Max. Continuous Operating Temperature\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e4 AWG\u003cbr\u003e\u003cstrong\u003e• No of conductor: \u003c\/strong\u003e2\u003cbr\u003e\u003cstrong\u003e• No of Strands: \u003c\/strong\u003e7\u003cbr\u003e\u003cstrong\u003e• Insulation thickness ( mil ): \u003c\/strong\u003e60\u003cbr\u003e\u003cstrong\u003e• Ground No x AWG:\u003c\/strong\u003e 1 x 8\u003cbr\u003e\u003cstrong\u003e• Inner Jacket thickness ( mil ):\u003c\/strong\u003e 85\u003cbr\u003e\u003cstrong\u003e• Dia. Over Armour ( Inch ):\u003c\/strong\u003e 1.144\u003cbr\u003e\u003cstrong\u003e• Overall Jacket thickness ( mil ): \u003c\/strong\u003e55\u003cbr\u003e\u003cstrong\u003e• Approx. OD ( Inch ): \u003c\/strong\u003e1.254\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (lb\/1000ft): \u003c\/strong\u003e759\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity In Raceway 90°C†: \u003c\/strong\u003e95 Amp\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27488110313572,"sku":"NNC3998X","price":9.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/teck90_b7b895b5-c01a-42cb-bf59-df839b3ff943.png?v=1762459144"},{"product_id":"3-3-teck-90-bare-copper-aluminum-interlocked-armored-cable-with-ground-1kv","title":"3\/3 Teck 90 Bare Copper Aluminum Interlocked Armored Cable With Ground 1KV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Teck_90_AL_1kv.pdf?v=1742394179\" width=\"\" height=\"\" type=\"application\/pdf\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e3\/3 Teck 90 Bare Copper Aluminum Interlocked Armored Cable With Ground 1KV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eFor exposed or concealed wiring in wet or dry locations. For use in ventilated, non ventilated and ladder type cable troughs and ventilated flexible cableway in wet, dry, or hazardous locations. Sunlight Resistant. Typical applications are for control. lighting and power circuits in: pulp and paper mills, steel mills, food processing plants, commercial centers, mines, generating stations, refineries, industrial plants and chemical plants. Rated for 1000 lbs.\/FT maximum sidewall pressure. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e3\/3 AWG \u003c\/span\u003eTeck 90 cable ,1KV armored cable, 3\/3\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eAWG \u003c\/span\u003eBare copper interlocked cable, Aluminum armored cable, Teck 90 1KV rating, 3\/3\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eAWG \u003c\/span\u003eInterlocked armored cable, Bare copper aluminum cable, 3\/3\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eAWG \u003c\/span\u003eArmored electrical cable.\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eClass B stranded copper, compressed or compact, in accordance with ASTM B3 and B8.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCross-Linked Polyethylene (XLPE), Colour Code: 2\/C black, white; 3\/C red, black, blue; 4\/C red, black, blue, white For cables larger than No. 2 AWG or more than 4\/C, the insulation is black and numbered\u003cbr\u003e\u003cstrong\u003e• Grounding Conductors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUninsulated Class B stranded grounding conductor\u003cbr\u003e\u003cstrong\u003e• Inner Jacket:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBlack Polyvinyl Chloride (PVC)\u003cbr\u003e\u003cstrong\u003e• Armor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAluminum Interlocked Armour (AIA)\u003cbr\u003e\u003cstrong\u003e• Overall Jacket:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBlack PVC (optional colours available)\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA C22.2 No. 174 Cables in Hazardous Locations\u003cbr\u003e• CSA C22.2 No. 131 Type TECK 90 Cable\u003cbr\u003e• CSA C22.2 No. 2556 \u0026amp; No. 0.3 Wire and Cable Test Methods\u003cbr\u003e• CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating\u003cbr\u003e• CSA HL - for Hazardous Locations rating\u003cbr\u003e• CSA SUN RES - for Sunlight Resistant rating\u003cbr\u003e• CSA AG14 - Acid Gas Compliance\u003cbr\u003e• IEEE 383 Flame Test (70,000 btu)\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1000V Multi Conductor, 8AWG -1000 Kcmil Copper, FT4 - Flame Retardancy Rating, XLPE Insulation, Aluminum Interlocked Armour, Sunlight Resistant, -40°C - 90°C, Rated HL, AG14\u003cbr\u003e\u003cbr\u003e•  -40°C - CSA Cold Bend and Impact Temperature\u003cbr\u003e• -25°C - Min. Installation Temperature\u003cbr\u003e• 90°C - Max. Continuous Operating Temperature\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e3 AWG\u003cbr\u003e\u003cstrong\u003e• No of conductor: \u003c\/strong\u003e3\u003cbr\u003e\u003cstrong\u003e• Insulation thickness ( mil ): \u003c\/strong\u003e60\u003cbr\u003e\u003cstrong\u003e• Ground No x AWG:\u003c\/strong\u003e 1 x 6\u003cbr\u003e\u003cstrong\u003e• Inner Jacket thickness ( mil ):\u003c\/strong\u003e 80\u003cbr\u003e\u003cstrong\u003e• Dia. Over Armour ( Inch ):\u003c\/strong\u003e 1.236\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (lb\/1000ft):\u003c\/strong\u003e 1026\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 391px; height: 78px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"width: 381px; height: 21px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eHouston Wire \u0026amp; Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eHW331 00303\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27488110346340,"sku":"NNC3999X","price":14.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/teck90_13122046-2215-4ea0-b8de-973d46bd84df.png?v=1762459145"},{"product_id":"3-4-teck-90-bare-copper-aluminum-interlocked-armored-cable-with-ground-1kv","title":"3\/4 Teck 90 Bare Copper Aluminum Interlocked Armored Cable With Ground 1KV","description":"\u003cp\u003e[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Teck_90_AL_1kv.pdf?v=1742394179\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e3\/4 Teck 90 Bare Copper Aluminum Interlocked Armored Cable With Ground 1KV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eFor exposed or concealed wiring in wet or dry locations. For use in ventilated, non ventilated and ladder type cable troughs and ventilated flexible cableway in wet, dry, or hazardous locations. Sunlight Resistant. Typical applications are for control. lighting and power circuits in: pulp and paper mills, steel mills, food processing plants, commercial centers, mines, generating stations, refineries, industrial plants and chemical plants. Rated for 1000 lbs.\/FT maximum sidewall pressure. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e3\/4 AWG \u003c\/span\u003eTeck 90 cable ,1KV armored cable, 3\/4\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eAWG \u003c\/span\u003eBare copper interlocked cable, Aluminum armored cable, Teck 90 1KV rating, 3\/4\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eAWG \u003c\/span\u003eInterlocked armored cable, Bare copper aluminum cable, 3\/4\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eAWG \u003c\/span\u003eArmored electrical cable.\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eClass B stranded copper, compressed or compact, in accordance with ASTM B3 and B8.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCross-Linked Polyethylene (XLPE), Colour Code: 2\/C black, white; 3\/C red, black, blue; 4\/C red, black, blue, white For cables larger than No. 2 AWG or more than 4\/C, the insulation is black and numbered\u003cbr\u003e\u003cstrong\u003e• Grounding Conductors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUninsulated Class B stranded grounding conductor\u003cbr\u003e\u003cstrong\u003e• Inner Jacket:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBlack Polyvinyl Chloride (PVC)\u003cbr\u003e\u003cstrong\u003e• Armor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAluminum Interlocked Armour (AIA)\u003cbr\u003e\u003cstrong\u003e• Overall Jacket:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBlack PVC (optional colours available)\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA C22.2 No. 174 Cables in Hazardous Locations\u003cbr\u003e• CSA C22.2 No. 131 Type TECK 90 Cable\u003cbr\u003e• CSA C22.2 No. 2556 \u0026amp; No. 0.3 Wire and Cable Test Methods\u003cbr\u003e• CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating\u003cbr\u003e• CSA HL - for Hazardous Locations rating\u003cbr\u003e• CSA SUN RES - for Sunlight Resistant rating\u003cbr\u003e• CSA AG14 - Acid Gas Compliance\u003cbr\u003e• IEEE 383 Flame Test (70,000 btu)\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1000V Multi Conductor, 8AWG -1000 Kcmil Copper, FT4 - Flame Retardancy Rating, XLPE Insulation, Aluminum Interlocked Armour, Sunlight Resistant, -40°C - 90°C, Rated HL, AG14\u003cbr\u003e\u003cbr\u003e•  -40°C - CSA Cold Bend and Impact Temperature\u003cbr\u003e• -25°C - Min. Installation Temperature\u003cbr\u003e• 90°C - Max. Continuous Operating Temperature\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e3 AWG\u003cbr\u003e\u003cstrong\u003e• No of conductor: \u003c\/strong\u003e4\u003cbr\u003e\u003cstrong\u003e• No of Strands: \u003c\/strong\u003e7\u003cbr\u003e\u003cstrong\u003e• Insulation thickness ( mil ): \u003c\/strong\u003e60\u003cbr\u003e\u003cstrong\u003e• Ground No x AWG:\u003c\/strong\u003e 1 x 6\u003cbr\u003e\u003cstrong\u003e• Inner Jacket thickness ( mil ):\u003c\/strong\u003e 80\u003cbr\u003e\u003cstrong\u003e• Dia. Over Armour ( Inch ):\u003c\/strong\u003e 1.360\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (lb\/1000ft):\u003c\/strong\u003e 1359\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 391px; height: 78px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"width: 381px; height: 21px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eService Wire Co :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eCAAC3\/4U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 185.469px;\"\u003e\u003cstrong\u003eHouston Wire \u0026amp; Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px;\"\u003eHW331 00304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27488110411876,"sku":"NNC4000X","price":18.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/teck90_f859f06c-3307-425f-a40b-da5c1bb96c7d.png?v=1762459145"},{"product_id":"2-4-teck-90-bare-copper-aluminum-interlocked-armored-cable-with-ground-1kv","title":"2\/4 Teck 90 Bare Copper Aluminum Interlocked Armored Cable With Ground 1KV","description":"\u003cp\u003e[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Teck_90_AL_1kv.pdf?v=1742394179\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2\/4 Teck 90 Bare Copper Aluminum Interlocked Armored Cable With Ground 1KV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\n\u003cb\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003eApplications:\u003c\/b\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eFor exposed or concealed wiring in wet or dry locations. For use in ventilated, non ventilated and ladder type cable troughs and ventilated flexible cableway in wet, dry, or hazardous locations. Sunlight Resistant. Typical applications are for control. lighting and power circuits in: pulp and paper mills, steel mills, food processing plants, commercial centers, mines, generating stations, refineries, industrial plants and chemical plants. Rated for 1000 lbs.\/FT maximum sidewall pressure. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e2\/4 AWG \u003c\/span\u003eTeck 90 cable ,1KV armored cable, 2\/4\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eAWG \u003c\/span\u003eBare copper interlocked cable, Aluminum armored cable, Teck 90 1KV rating, 2\/4 \u003cspan\u003eAWG \u003c\/span\u003eInterlocked armored cable, Bare copper aluminum cable, 2\/4\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eAWG \u003c\/span\u003eArmored electrical cable.\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eClass B stranded copper, compressed or compact, in accordance with ASTM B3 and B8.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCross-Linked Polyethylene (XLPE), Colour Code: 2\/C black, white; 3\/C red, black, blue; 4\/C red, black, blue, white For cables larger than No. 2 AWG or more than 4\/C, the insulation is black and numbered\u003cbr\u003e\u003cstrong\u003e• Grounding Conductors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUninsulated Class B stranded grounding conductor\u003cbr\u003e\u003cstrong\u003e• Inner Jacket:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBlack Polyvinyl Chloride (PVC)\u003cbr\u003e\u003cstrong\u003e• Armor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAluminum Interlocked Armour (AIA)\u003cbr\u003e\u003cstrong\u003e• Overall Jacket:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBlack PVC (optional colours available)\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA C22.2 No. 174 Cables in Hazardous Locations\u003cbr\u003e• CSA C22.2 No. 131 Type TECK 90 Cable\u003cbr\u003e• CSA C22.2 No. 2556 \u0026amp; No. 0.3 Wire and Cable Test Methods\u003cbr\u003e• CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating\u003cbr\u003e• CSA HL - for Hazardous Locations rating\u003cbr\u003e• CSA SUN RES - for Sunlight Resistant rating\u003cbr\u003e• CSA AG14 - Acid Gas Compliance\u003cbr\u003e• IEEE 383 Flame Test (70,000 btu)\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1000V Multi Conductor, 8AWG -1000 Kcmil Copper, FT4 - Flame Retardancy Rating, XLPE Insulation, Aluminum Interlocked Armour, Sunlight Resistant, -40°C - 90°C, Rated HL, AG14\u003cbr\u003e\u003cbr\u003e•  -40°C - CSA Cold Bend and Impact Temperature\u003cbr\u003e• -25°C - Min. Installation Temperature\u003cbr\u003e• 90°C - Max. Continuous Operating Temperature\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e2 AWG\u003cbr\u003e\u003cstrong\u003e• No of conductor: \u003c\/strong\u003e4\u003cbr\u003e\u003cstrong\u003e• No of Strands: \u003c\/strong\u003e7\u003cbr\u003e\u003cstrong\u003e• Insulation thickness ( mil ): \u003c\/strong\u003e60\u003cbr\u003e\u003cstrong\u003e• Ground No x AWG:\u003c\/strong\u003e 1x6\u003cbr\u003e\u003cstrong\u003e• Inner Jacket thickness ( mil ):\u003c\/strong\u003e 85\u003cbr\u003e\u003cstrong\u003e• Dia. Over Armour ( Inch ):\u003c\/strong\u003e 1.465\u003cbr\u003e\u003cstrong\u003e• Overall Jacket thickness ( mil ): \u003c\/strong\u003e45\u003cbr\u003e\u003cstrong\u003e• Approx. OD ( Inch ): \u003c\/strong\u003e1.555\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (lb\/1000ft):\u003c\/strong\u003e 1561\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity In Raceway 90°C†: \u003c\/strong\u003e104 Amp\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable height=\"181\" style=\"width: 352px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"width: 342px; height: 21px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cspan\u003eCompatible with Manufacturer\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 155.766px;\"\u003e\u003cstrong\u003eNexans :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 180.234px;\"\u003e\n\u003cstrong\u003eBlack :\u003c\/strong\u003e 383646\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 155.766px;\"\u003e\u003cstrong\u003eOmni Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 180.234px;\"\u003e\n\u003cstrong\u003eBlack :\u003c\/strong\u003e T30204\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 155.766px;\"\u003e\u003cstrong\u003eService Wire Co :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 180.234px;\"\u003e\n\u003cstrong\u003eBlack : \u003c\/strong\u003eCAAC2\/4U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 155.766px;\"\u003e\u003cstrong\u003eHouston Wire \u0026amp; Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 180.234px;\"\u003e\n\u003cstrong\u003eBlack : \u003c\/strong\u003eHW331 00204\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27488110575716,"sku":"NNC4002X","price":22.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/teck90_3f546b50-e125-4fa4-a717-a85f0783cc9a.png?v=1762459146"},{"product_id":"1-4-teck-90-bare-copper-aluminum-interlocked-armored-cable-with-ground-1kv","title":"1\/4 Teck 90 Bare Copper Aluminum Interlocked Armored Cable With Ground 1KV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Teck_90_AL_1kv.pdf?v=1742394179\" width=\"\" height=\"\" type=\"application\/pdf\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1\/4 Teck 90 Bare Copper Aluminum Interlocked Armored Cable With Ground 1KV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eFor exposed or concealed wiring in wet or dry locations. For use in ventilated, non ventilated and ladder type cable troughs and ventilated flexible cableway in wet, dry, or hazardous locations. Sunlight Resistant. Typical applications are for control. lighting and power circuits in: pulp and paper mills, steel mills, food processing plants, commercial centers, mines, generating stations, refineries, industrial plants and chemical plants. Rated for 1000 lbs.\/FT maximum sidewall pressure. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e1\/4 AWG \u003c\/span\u003eTeck 90 cable ,1KV armored cable,\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e1\/4\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eAWG \u003c\/span\u003eBare copper interlocked cable, Aluminum armored cable, Teck 90 1KV rating,\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e1\/4\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eAWG \u003c\/span\u003eInterlocked armored cable, Bare copper aluminum cable,\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e1\/4\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eAWG \u003c\/span\u003eArmored electrical cable.\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eClass B stranded copper, compressed or compact, in accordance with ASTM B3 and B8.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCross-Linked Polyethylene (XLPE), Colour Code: 2\/C black, white; 3\/C red, black, blue; 4\/C red, black, blue, white For cables larger than No. 2 AWG or more than 4\/C, the insulation is black and numbered\u003cbr\u003e\u003cstrong\u003e• Grounding Conductors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUninsulated Class B stranded grounding conductor\u003cbr\u003e\u003cstrong\u003e• Inner Jacket:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBlack Polyvinyl Chloride (PVC)\u003cbr\u003e\u003cstrong\u003e• Armor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAluminum Interlocked Armour (AIA)\u003cbr\u003e\u003cstrong\u003e• Overall Jacket:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBlack PVC (optional colours available)\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA C22.2 No. 174 Cables in Hazardous Locations\u003cbr\u003e• CSA C22.2 No. 131 Type TECK 90 Cable\u003cbr\u003e• CSA C22.2 No. 2556 \u0026amp; No. 0.3 Wire and Cable Test Methods\u003cbr\u003e• CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating\u003cbr\u003e• CSA HL - for Hazardous Locations rating\u003cbr\u003e• CSA SUN RES - for Sunlight Resistant rating\u003cbr\u003e• CSA AG14 - Acid Gas Compliance\u003cbr\u003e• IEEE 383 Flame Test (70,000 btu)\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1000V Multi Conductor, 8AWG -1000 Kcmil Copper, FT4 - Flame Retardancy Rating, XLPE Insulation, Aluminum Interlocked Armour, Sunlight Resistant, -40°C - 90°C, Rated HL, AG14\u003cbr\u003e\u003cbr\u003e•  -40°C - CSA Cold Bend and Impact Temperature\u003cbr\u003e• -25°C - Min. Installation Temperature\u003cbr\u003e• 90°C - Max. Continuous Operating Temperature\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e1 AWG\u003cbr\u003e\u003cstrong\u003e• No of conductor: \u003c\/strong\u003e4\u003cbr\u003e\u003cstrong\u003e• No of Strands: \u003c\/strong\u003e19\u003cbr\u003e\u003cstrong\u003e• Insulation thickness ( mil ): \u003c\/strong\u003e80\u003cbr\u003e\u003cstrong\u003e• Ground No x AWG:\u003c\/strong\u003e 1x6\u003cbr\u003e\u003cstrong\u003e• Inner Jacket thickness ( mil ):\u003c\/strong\u003e 85\u003cbr\u003e\u003cstrong\u003e• Dia. Over Armour ( Inch ):\u003c\/strong\u003e  1.672\u003cbr\u003e\u003cstrong\u003e• Overall Jacket thickness ( mil ): \u003c\/strong\u003e55\u003cbr\u003e\u003cstrong\u003e• Approx. OD ( Inch ): \u003c\/strong\u003e1.782\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (lb\/1000ft):\u003c\/strong\u003e 1981 \u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity In Raceway 90°C†:  \u003c\/strong\u003e116 Amp\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 391px; height: 78px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 381px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eHouston Wire \u0026amp; Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003e\u003cspan\u003eHW331 00104\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27488110772324,"sku":"NNC4004X","price":25.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/teck90_cccc41ea-e9d6-4a3b-a87e-0c18d29d6368.png?v=1762459146"},{"product_id":"1-0-4-teck-90-bare-copper-aluminum-interlocked-armored-cable-with-ground-1kv","title":"1\/0-4 Teck 90 Bare Copper Aluminum Interlocked Armored Cable With Ground 1KV","description":"\u003cp\u003e[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Teck_90_AL_1kv.pdf?v=1742394179\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1\/0-4 Teck 90 Bare Copper Aluminum Interlocked Armored Cable With Ground 1KV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eFor exposed or concealed wiring in wet or dry locations. For use in ventilated, non ventilated and ladder type cable troughs and ventilated flexible cableway in wet, dry, or hazardous locations. Sunlight Resistant. Typical applications are for control. lighting and power circuits in: pulp and paper mills, steel mills, food processing plants, commercial centers, mines, generating stations, refineries, industrial plants and chemical plants. Rated for 1000 lbs.\/FT maximum sidewall pressure. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e1\/0-4 AWG \u003c\/span\u003eTeck 90 cable ,1KV armored cable,\u003cspan\u003e 1\/0-4 \u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eAWG \u003c\/span\u003eBare copper interlocked cable, Aluminum armored cable, Teck 90 1KV rating,\u003cspan\u003e 1\/0-4 \u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eAWG \u003c\/span\u003eInterlocked armored cable, Bare copper aluminum cable,\u003cspan\u003e 1\/0-4 \u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eAWG \u003c\/span\u003eArmored electrical cable.\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eClass B stranded copper, compressed or compact, in accordance with ASTM B3 and B8.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCross-Linked Polyethylene (XLPE), Colour Code: 2\/C black, white; 3\/C red, black, blue; 4\/C red, black, blue, white For cables larger than No. 2 AWG or more than 4\/C, the insulation is black and numbered\u003cbr\u003e\u003cstrong\u003e• Grounding Conductors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUninsulated Class B stranded grounding conductor\u003cbr\u003e\u003cstrong\u003e• Inner Jacket:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBlack Polyvinyl Chloride (PVC)\u003cbr\u003e\u003cstrong\u003e• Armor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAluminum Interlocked Armour (AIA)\u003cbr\u003e\u003cstrong\u003e• Overall Jacket:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBlack PVC (optional colours available)\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA C22.2 No. 174 Cables in Hazardous Locations\u003cbr\u003e• CSA C22.2 No. 131 Type TECK 90 Cable\u003cbr\u003e• CSA C22.2 No. 2556 \u0026amp; No. 0.3 Wire and Cable Test Methods\u003cbr\u003e• CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating\u003cbr\u003e• CSA HL - for Hazardous Locations rating\u003cbr\u003e• CSA SUN RES - for Sunlight Resistant rating\u003cbr\u003e• CSA AG14 - Acid Gas Compliance\u003cbr\u003e• IEEE 383 Flame Test (70,000 btu)\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1000V Multi Conductor, 8AWG -1000 Kcmil Copper, FT4 - Flame Retardancy Rating, XLPE Insulation, Aluminum Interlocked Armour, Sunlight Resistant, -40°C - 90°C, Rated HL, AG14\u003cbr\u003e\u003cbr\u003e•  -40°C - CSA Cold Bend and Impact Temperature\u003cbr\u003e• -25°C - Min. Installation Temperature\u003cbr\u003e• 90°C - Max. Continuous Operating Temperature\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e1\/0\u003cspan\u003e AWG\u003cbr\u003e\u003cstrong\u003e• No of conductor: \u003c\/strong\u003e4\u003cbr\u003e\u003cstrong\u003e• No of Strands: \u003c\/strong\u003e19\u003cbr\u003e\u003cstrong\u003e• Insulation thickness ( mil ): \u003c\/strong\u003e80\u003cbr\u003e\u003cstrong\u003e• Ground No x AWG:\u003c\/strong\u003e 1x6\u003cbr\u003e\u003cstrong\u003e• Inner Jacket thickness ( mil ):\u003c\/strong\u003e 85\u003cbr\u003e\u003cstrong\u003e• Dia. Over Armour ( Inch ):\u003c\/strong\u003e 1.766\u003cbr\u003e\u003cstrong\u003e• Overall Jacket thickness ( mil ): \u003c\/strong\u003e55\u003cbr\u003e\u003cstrong\u003e• Approx. OD ( Inch ): \u003c\/strong\u003e 1.876\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (lb\/1000ft):\u003c\/strong\u003e  2315\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity In Raceway 90°C†: \u003c\/strong\u003e136 Amp\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 391px; height: 78px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"width: 381px; height: 21px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eService Wire Co :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eCAAC1\/04U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 185.469px;\"\u003e\u003cstrong\u003eHouston Wire \u0026amp; Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px;\"\u003e\u003cspan\u003eHW331 10104\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National cable","offers":[{"title":"Default Title","offer_id":27488111100004,"sku":"NNC4005X","price":29.18,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/teck90_a6634c9e-209d-441b-99e8-65dc5e60d77a.png?v=1762459148"},{"product_id":"2-0-4-teck-90-bare-copper-aluminum-interlocked-armored-cable-with-ground-1kv","title":"2\/0-4 Teck 90 Bare Copper Aluminum Interlocked Armored Cable With Ground 1KV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Teck_90_AL_1kv.pdf?v=1742394179\" width=\"\" height=\"\" type=\"application\/pdf\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2\/0-4 Teck 90 Bare Copper Aluminum Interlocked Armored Cable With Ground 1KV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eFor exposed or concealed wiring in wet or dry locations. For use in ventilated, non ventilated and ladder type cable troughs and ventilated flexible cableway in wet, dry, or hazardous locations. Sunlight Resistant. Typical applications are for control. lighting and power circuits in: pulp and paper mills, steel mills, food processing plants, commercial centers, mines, generating stations, refineries, industrial plants and chemical plants. Rated for 1000 lbs.\/FT maximum sidewall pressure. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e2\/0-4 AWG \u003c\/span\u003eTeck 90 cable ,1KV armored cable,\u003cspan\u003e 2\/0-4 \u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eAWG \u003c\/span\u003eBare copper interlocked cable, Aluminum armored cable, Teck 90 1KV rating,\u003cspan\u003e 2\/0-4 \u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eAWG \u003c\/span\u003eInterlocked armored cable, Bare copper aluminum cable,\u003cspan\u003e 2\/0-4 \u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eAWG \u003c\/span\u003eArmored electrical cable.\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eClass B stranded copper, compressed or compact, in accordance with ASTM B3 and B8.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCross-Linked Polyethylene (XLPE), Colour Code: 2\/C black, white; 3\/C red, black, blue; 4\/C red, black, blue, white For cables larger than No. 2 AWG or more than 4\/C, the insulation is black and numbered\u003cbr\u003e\u003cstrong\u003e• Grounding Conductors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUninsulated Class B stranded grounding conductor\u003cbr\u003e\u003cstrong\u003e• Inner Jacket:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBlack Polyvinyl Chloride (PVC)\u003cbr\u003e\u003cstrong\u003e• Armor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAluminum Interlocked Armour (AIA)\u003cbr\u003e\u003cstrong\u003e• Overall Jacket:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBlack PVC (optional colours available)\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA C22.2 No. 174 Cables in Hazardous Locations\u003cbr\u003e• CSA C22.2 No. 131 Type TECK 90 Cable\u003cbr\u003e• CSA C22.2 No. 2556 \u0026amp; No. 0.3 Wire and Cable Test Methods\u003cbr\u003e• CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating\u003cbr\u003e• CSA HL - for Hazardous Locations rating\u003cbr\u003e• CSA SUN RES - for Sunlight Resistant rating\u003cbr\u003e• CSA AG14 - Acid Gas Compliance\u003cbr\u003e• IEEE 383 Flame Test (70,000 btu)\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1000V Multi Conductor, 8AWG -1000 Kcmil Copper, FT4 - Flame Retardancy Rating, XLPE Insulation, Aluminum Interlocked Armour, Sunlight Resistant, -40°C - 90°C, Rated HL, AG14\u003cbr\u003e\u003cbr\u003e•  -40°C - CSA Cold Bend and Impact Temperature\u003cbr\u003e• -25°C - Min. Installation Temperature\u003cbr\u003e• 90°C - Max. Continuous Operating Temperature\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e2\/0\u003cspan\u003e AWG\u003cbr\u003e\u003cstrong\u003e• No of conductor: \u003c\/strong\u003e4\u003cbr\u003e\u003cstrong\u003e• No of Strands: \u003c\/strong\u003e19\u003cbr\u003e\u003cstrong\u003e• Insulation thickness ( mil ): \u003c\/strong\u003e80\u003cbr\u003e\u003cstrong\u003e• Ground No x AWG:\u003c\/strong\u003e 1x6\u003cbr\u003e\u003cstrong\u003e• Inner Jacket thickness ( mil ):\u003c\/strong\u003e 85\u003cbr\u003e\u003cstrong\u003e• Dia. Over Armour ( Inch ):\u003c\/strong\u003e 1.885\u003cbr\u003e\u003cstrong\u003e• Overall Jacket thickness ( mil ): \u003c\/strong\u003e55\u003cbr\u003e\u003cstrong\u003e• Approx. OD ( Inch ): \u003c\/strong\u003e1.995\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (lb\/1000ft):\u003c\/strong\u003e 2787\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity In Raceway 90°C†: \u003c\/strong\u003e156 Amp\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 391px; height: 78px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 381px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eService Wire Co :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eCAAC2\/04U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 185.469px;\"\u003e\u003cstrong\u003eHouston Wire \u0026amp; Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px;\"\u003eHW331 20104\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27488111329380,"sku":"NNC4008X","price":33.58,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/teck90_1ee782db-12fc-4419-b86c-d335dc852072.png?v=1762459148"},{"product_id":"3-0-4-teck-90-bare-copper-aluminum-interlocked-armored-cable-with-ground-1kv","title":"3\/0-4 Teck 90 Bare Copper Aluminum Interlocked Armored Cable With Ground 1KV","description":"\u003cp\u003e[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Teck_90_AL_1kv.pdf?v=1742394179\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e3\/0-4 Teck 90 Bare Copper Aluminum Interlocked Armored Cable With Ground 1KV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eFor exposed or concealed wiring in wet or dry locations. For use in ventilated, non ventilated and ladder type cable troughs and ventilated flexible cableway in wet, dry, or hazardous locations. Sunlight Resistant. Typical applications are for control. lighting and power circuits in: pulp and paper mills, steel mills, food processing plants, commercial centers, mines, generating stations, refineries, industrial plants and chemical plants. Rated for 1000 lbs.\/FT maximum sidewall pressure. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e3\/0-4 AWG \u003c\/span\u003eTeck 90 cable ,1KV armored cable,\u003cspan\u003e 3\/0-4 \u003c\/span\u003e\u003cspan\u003eAWG \u003c\/span\u003eBare copper interlocked cable, Aluminum armored cable, Teck 90 1KV rating,\u003cspan\u003e 3\/0-4 \u003c\/span\u003e\u003cspan\u003eAWG \u003c\/span\u003eInterlocked armored cable, Bare copper aluminum cable,\u003cspan\u003e 3\/0-4 \u003c\/span\u003e\u003cspan\u003eAWG \u003c\/span\u003eArmored electrical cable.\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eClass B stranded copper, compressed or compact, in accordance with ASTM B3 and B8.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCross-Linked Polyethylene (XLPE), Colour Code: 2\/C black, white; 3\/C red, black, blue; 4\/C red, black, blue, white For cables larger than No. 2 AWG or more than 4\/C, the insulation is black and numbered\u003cbr\u003e\u003cstrong\u003e• Grounding Conductors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUninsulated Class B stranded grounding conductor\u003cbr\u003e\u003cstrong\u003e• Inner Jacket:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBlack Polyvinyl Chloride (PVC)\u003cbr\u003e\u003cstrong\u003e• Armor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAluminum Interlocked Armour (AIA)\u003cbr\u003e\u003cstrong\u003e• Overall Jacket:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBlack PVC (optional colours available)\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA C22.2 No. 174 Cables in Hazardous Locations\u003cbr\u003e• CSA C22.2 No. 131 Type TECK 90 Cable\u003cbr\u003e• CSA C22.2 No. 2556 \u0026amp; No. 0.3 Wire and Cable Test Methods\u003cbr\u003e• CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating\u003cbr\u003e• CSA HL - for Hazardous Locations rating\u003cbr\u003e• CSA SUN RES - for Sunlight Resistant rating\u003cbr\u003e• CSA AG14 - Acid Gas Compliance\u003cbr\u003e• IEEE 383 Flame Test (70,000 btu)\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1000V Multi Conductor, 8AWG -1000 Kcmil Copper, FT4 - Flame Retardancy Rating, XLPE Insulation, Aluminum Interlocked Armour, Sunlight Resistant, -40°C - 90°C, Rated HL, AG14\u003cbr\u003e\u003cbr\u003e•  -40°C - CSA Cold Bend and Impact Temperature\u003cbr\u003e• -25°C - Min. Installation Temperature\u003cbr\u003e• 90°C - Max. Continuous Operating Temperature\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3\/0\u003cspan\u003e AWG\u003cbr\u003e\u003cstrong\u003e• No of conductor: \u003c\/strong\u003e4\u003cbr\u003e\u003cstrong\u003e• No of Strands: \u003c\/strong\u003e19\u003cbr\u003e\u003cstrong\u003e• Insulation thickness ( mil ): \u003c\/strong\u003e80\u003cbr\u003e\u003cstrong\u003e• Ground No x AWG:\u003c\/strong\u003e 1x4\u003cbr\u003e\u003cstrong\u003e• Inner Jacket thickness ( mil ):\u003c\/strong\u003e 115\u003cbr\u003e\u003cstrong\u003e• Dia. Over Armour ( Inch ):\u003c\/strong\u003e 1.989\u003cbr\u003e\u003cstrong\u003e• Overall Jacket thickness ( mil ): \u003c\/strong\u003e55\u003cbr\u003e\u003cstrong\u003e• Approx. OD ( Inch ): \u003c\/strong\u003e 2.099\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (lb\/1000ft):\u003c\/strong\u003e 3342\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity In Raceway 90°C†: \u003c\/strong\u003e180 Amp\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 391px; height: 78px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 381px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eService Wire Co :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eCAAC3\/04U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 185.469px;\"\u003e\u003cstrong\u003eHouston Wire \u0026amp; Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px;\"\u003eHW331 30103\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 185.469px;\"\u003e\u003cstrong\u003eNexans :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px;\"\u003e568279\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27488111460452,"sku":"NNC4010X","price":51.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/teck90_ead6907f-1bd6-4cd5-af62-6601f9cab563.png?v=1762459150"},{"product_id":"4-0-4-teck-90-bare-copper-aluminum-interlocked-armored-cable-with-ground-1kv","title":"4\/0-4 Teck 90 Bare Copper Aluminum Interlocked Armored Cable With Ground 1KV","description":"\u003cp\u003e[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Teck_90_AL_1kv.pdf?v=1742394179\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e4\/0-4 Teck 90 Bare Copper Aluminum Interlocked Armored Cable With Ground 1KV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eFor exposed or concealed wiring in wet or dry locations. For use in ventilated, non ventilated and ladder type cable troughs and ventilated flexible cableway in wet, dry, or hazardous locations. Sunlight Resistant. Typical applications are for control. lighting and power circuits in: pulp and paper mills, steel mills, food processing plants, commercial centers, mines, generating stations, refineries, industrial plants and chemical plants. Rated for 1000 lbs.\/FT maximum sidewall pressure. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e4\/0-4 AWG \u003c\/span\u003eTeck 90 cable ,1KV armored cable,\u003cspan\u003e 4\/0-4 \u003c\/span\u003e\u003cspan\u003eAWG \u003c\/span\u003eBare copper interlocked cable, Aluminum armored cable, Teck 90 1KV rating,\u003cspan\u003e 4\/0-4 \u003c\/span\u003e\u003cspan\u003eAWG \u003c\/span\u003eInterlocked armored cable, Bare copper aluminum cable,\u003cspan\u003e 4\/0-4 \u003c\/span\u003e\u003cspan\u003eAWG \u003c\/span\u003eArmored electrical cable.\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eClass B stranded copper, compressed or compact, in accordance with ASTM B3 and B8.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCross-Linked Polyethylene (XLPE), Colour Code: 2\/C black, white; 3\/C red, black, blue; 4\/C red, black, blue, white For cables larger than No. 2 AWG or more than 4\/C, the insulation is black and numbered\u003cbr\u003e\u003cstrong\u003e• Grounding Conductors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUninsulated Class B stranded grounding conductor\u003cbr\u003e\u003cstrong\u003e• Inner Jacket:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBlack Polyvinyl Chloride (PVC)\u003cbr\u003e\u003cstrong\u003e• Armor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAluminum Interlocked Armour (AIA)\u003cbr\u003e\u003cstrong\u003e• Overall Jacket:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBlack PVC (optional colours available)\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA C22.2 No. 174 Cables in Hazardous Locations\u003cbr\u003e• CSA C22.2 No. 131 Type TECK 90 Cable\u003cbr\u003e• CSA C22.2 No. 2556 \u0026amp; No. 0.3 Wire and Cable Test Methods\u003cbr\u003e• CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating\u003cbr\u003e• CSA HL - for Hazardous Locations rating\u003cbr\u003e• CSA SUN RES - for Sunlight Resistant rating\u003cbr\u003e• CSA AG14 - Acid Gas Compliance\u003cbr\u003e• IEEE 383 Flame Test (70,000 btu)\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1000V Multi Conductor, 8AWG -1000 Kcmil Copper, FT4 - Flame Retardancy Rating, XLPE Insulation, Aluminum Interlocked Armour, Sunlight Resistant, -40°C - 90°C, Rated HL, AG14\u003cbr\u003e\u003cbr\u003e•  -40°C - CSA Cold Bend and Impact Temperature\u003cbr\u003e• -25°C - Min. Installation Temperature\u003cbr\u003e• 90°C - Max. Continuous Operating Temperature\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e4\/0\u003cspan\u003e AWG\u003cbr\u003e\u003cstrong\u003e• No of conductor: \u003c\/strong\u003e4\u003cbr\u003e\u003cstrong\u003e• No of Strands: \u003c\/strong\u003e19\u003cbr\u003e\u003cstrong\u003e• Insulation thickness ( mil ): \u003c\/strong\u003e80\u003cbr\u003e\u003cstrong\u003e• Ground No x AWG:\u003c\/strong\u003e 1x4\u003cbr\u003e\u003cstrong\u003e• Inner Jacket thickness ( mil ):\u003c\/strong\u003e 115\u003cbr\u003e\u003cstrong\u003e• Dia. Over Armour ( Inch ):\u003c\/strong\u003e 2.175\u003cbr\u003e\u003cstrong\u003e• Overall Jacket thickness ( mil ): \u003c\/strong\u003e65\u003cbr\u003e\u003cstrong\u003e• Approx. OD ( Inch ):\u003c\/strong\u003e  2.307\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (lb\/1000ft):\u003c\/strong\u003e  4149\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity In Raceway 90°C†: \u003c\/strong\u003e208 Amp\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 391px; height: 78px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"width: 381px; height: 21px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eNexans :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003e568709\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 185.469px;\"\u003e\u003cstrong\u003eService Wire Co :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px;\"\u003eCAAC4\/04U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 185.469px;\"\u003e\u003cstrong\u003eHouston Wire \u0026amp; Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px;\"\u003eHW331 40104\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27488111525988,"sku":"NNC4011X","price":56.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/teck90_d15c859c-ecbf-4e85-9741-7252ecce0f34.png?v=1762459150"},{"product_id":"250-4-teck-90-bare-copper-aluminum-interlocked-armored-cable-with-ground-1kv","title":"250-4 Teck 90 Bare Copper Aluminum Interlocked Armored Cable With Ground 1KV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Teck_90_AL_1kv.pdf?v=1742394179\" width=\"\" height=\"\" type=\"application\/pdf\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e250-4 Teck 90 Bare Copper Aluminum Interlocked Armored Cable With Ground 1KV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eFor exposed or concealed wiring in wet or dry locations. For use in ventilated, non ventilated and ladder type cable troughs and ventilated flexible cableway in wet, dry, or hazardous locations. Sunlight Resistant. Typical applications are for control. lighting and power circuits in: pulp and paper mills, steel mills, food processing plants, commercial centers, mines, generating stations, refineries, industrial plants and chemical plants. Rated for 1000 lbs.\/FT maximum sidewall pressure. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e250-4 MCM \u003c\/span\u003eTeck 90 cable ,1KV armored cable,\u003cspan\u003e 250-4 MCM\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eBare copper interlocked cable, Aluminum armored cable, Teck 90 1KV rating,\u003cspan\u003e 250-4 MCM\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eInterlocked armored cable, Bare copper aluminum cable,\u003cspan\u003e 250-4 MCM\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eArmored electrical cable.\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eClass B stranded copper, compressed or compact, in accordance with ASTM B3 and B8.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCross-Linked Polyethylene (XLPE), Colour Code: 2\/C black, white; 3\/C red, black, blue; 4\/C red, black, blue, white For cables larger than No. 2 AWG or more than 4\/C, the insulation is black and numbered\u003cbr\u003e\u003cstrong\u003e• Grounding Conductors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUninsulated Class B stranded grounding conductor\u003cbr\u003e\u003cstrong\u003e• Inner Jacket:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBlack Polyvinyl Chloride (PVC)\u003cbr\u003e\u003cstrong\u003e• Armor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAluminum Interlocked Armour (AIA)\u003cbr\u003e\u003cstrong\u003e• Overall Jacket:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBlack PVC (optional colours available)\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA C22.2 No. 174 Cables in Hazardous Locations\u003cbr\u003e• CSA C22.2 No. 131 Type TECK 90 Cable\u003cbr\u003e• CSA C22.2 No. 2556 \u0026amp; No. 0.3 Wire and Cable Test Methods\u003cbr\u003e• CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating\u003cbr\u003e• CSA HL - for Hazardous Locations rating\u003cbr\u003e• CSA SUN RES - for Sunlight Resistant rating\u003cbr\u003e• CSA AG14 - Acid Gas Compliance\u003cbr\u003e• IEEE 383 Flame Test (70,000 btu)\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1000V Multi Conductor, 8AWG -1000 Kcmil Copper, FT4 - Flame Retardancy Rating, XLPE Insulation, Aluminum Interlocked Armour, Sunlight Resistant, -40°C - 90°C, Rated HL, AG14\u003cbr\u003e\u003cbr\u003e•  -40°C - CSA Cold Bend and Impact Temperature\u003cbr\u003e• -25°C - Min. Installation Temperature\u003cbr\u003e• 90°C - Max. Continuous Operating Temperature\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e250 MCM\u003cspan\u003e\u003cbr\u003e\u003cstrong\u003e• No of conductor: \u003c\/strong\u003e4\u003cbr\u003e\u003cstrong\u003e• No of Strands:\u003c\/strong\u003e 37\u003cbr\u003e\u003cstrong\u003e• Insulation thickness ( mil ): \u003c\/strong\u003e90\u003cbr\u003e\u003cstrong\u003e• Ground No x AWG:\u003c\/strong\u003e 1x4\u003cbr\u003e\u003cstrong\u003e• Inner Jacket thickness ( mil ):\u003c\/strong\u003e 115\u003cbr\u003e\u003cstrong\u003e• Dia. Over Armour ( Inch ):\u003c\/strong\u003e  2.332\u003cbr\u003e\u003cstrong\u003e• Overall Jacket thickness ( mil ):\u003c\/strong\u003e 65\u003cbr\u003e\u003cstrong\u003e• Approx. OD ( Inch ): \u003c\/strong\u003e2.464\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (lb\/1000ft):\u003c\/strong\u003e 4773\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity In Raceway 90°C†:  \u003c\/strong\u003e232 Amp\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 391px; height: 78px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 381px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eService Wire Co :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eCAAC250\/4U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 185.469px;\"\u003e\u003cstrong\u003eHouston Wire \u0026amp; Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px;\"\u003eHW331 25004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27488111820900,"sku":"NNC4014X","price":62.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/teck90_0de1ae39-e50a-4b89-93f8-109abe51908d.png?v=1762459151"},{"product_id":"300-3-teck-90-bare-copper-aluminum-interlocked-armored-cable-with-ground-1kv","title":"300-3 Teck 90 Bare Copper Aluminum Interlocked Armored Cable With Ground 1KV","description":"\u003cp\u003e[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Teck_90_AL_1kv.pdf?v=1742394179\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e300-3 Teck 90 Bare Copper Aluminum Interlocked Armored Cable With Ground 1KV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eFor exposed or concealed wiring in wet or dry locations. For use in ventilated, non ventilated and ladder type cable troughs and ventilated flexible cableway in wet, dry, or hazardous locations. Sunlight Resistant. Typical applications are for control. lighting and power circuits in: pulp and paper mills, steel mills, food processing plants, commercial centers, mines, generating stations, refineries, industrial plants and chemical plants. Rated for 1000 lbs.\/FT maximum sidewall pressure. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e300-3 MCM \u003c\/span\u003eTeck 90 cable ,1KV armored cable,\u003cspan\u003e 300-3 MCM\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eBare copper interlocked cable, Aluminum armored cable, Teck 90 1KV rating,\u003cspan\u003e 300-3 MCM\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eInterlocked armored cable, Bare copper aluminum cable,\u003cspan\u003e 300-3 MCM\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eArmored electrical cable.\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eClass B stranded copper, compressed or compact, in accordance with ASTM B3 and B8.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCross-Linked Polyethylene (XLPE), Colour Code: 2\/C black, white; 3\/C red, black, blue; 4\/C red, black, blue, white For cables larger than No. 2 AWG or more than 4\/C, the insulation is black and numbered\u003cbr\u003e\u003cstrong\u003e• Grounding Conductors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUninsulated Class B stranded grounding conductor\u003cbr\u003e\u003cstrong\u003e• Inner Jacket:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBlack Polyvinyl Chloride (PVC)\u003cbr\u003e\u003cstrong\u003e• Armor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAluminum Interlocked Armour (AIA)\u003cbr\u003e\u003cstrong\u003e• Overall Jacket:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBlack PVC (optional colours available)\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA C22.2 No. 174 Cables in Hazardous Locations\u003cbr\u003e• CSA C22.2 No. 131 Type TECK 90 Cable\u003cbr\u003e• CSA C22.2 No. 2556 \u0026amp; No. 0.3 Wire and Cable Test Methods\u003cbr\u003e• CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating\u003cbr\u003e• CSA HL - for Hazardous Locations rating\u003cbr\u003e• CSA SUN RES - for Sunlight Resistant rating\u003cbr\u003e• CSA AG14 - Acid Gas Compliance\u003cbr\u003e• IEEE 383 Flame Test (70,000 btu)\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1000V Multi Conductor, 8AWG -1000 Kcmil Copper, FT4 - Flame Retardancy Rating, XLPE Insulation, Aluminum Interlocked Armour, Sunlight Resistant, -40°C - 90°C, Rated HL, AG14\u003cbr\u003e\u003cbr\u003e•  -40°C - CSA Cold Bend and Impact Temperature\u003cbr\u003e• -25°C - Min. Installation Temperature\u003cbr\u003e• 90°C - Max. Continuous Operating Temperature\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e300 MCM\u003cspan\u003e\u003cbr\u003e\u003cstrong\u003e• No of conductor: \u003c\/strong\u003e3\u003cbr\u003e\u003cstrong\u003e• No of Strands:\u003c\/strong\u003e 37\u003cbr\u003e\u003cstrong\u003e• Insulation thickness ( mil ): \u003c\/strong\u003e90\u003cbr\u003e\u003cstrong\u003e• Ground No x AWG:\u003c\/strong\u003e 1x4\u003cbr\u003e\u003cstrong\u003e• Inner Jacket thickness ( mil ):\u003c\/strong\u003e 115\u003cbr\u003e\u003cstrong\u003e• Dia. Over Armour ( Inch ):\u003c\/strong\u003e 2.295\u003cbr\u003e\u003cstrong\u003e• Overall Jacket thickness ( mil ):\u003c\/strong\u003e 65\u003cbr\u003e\u003cstrong\u003e• Approx. OD ( Inch ): \u003c\/strong\u003e2.427\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (lb\/1000ft):\u003c\/strong\u003e 4388\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity In Raceway 90°C†:  \u003c\/strong\u003e320 Amp\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 391px; height: 78px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 381px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eHouston Wire \u0026amp; Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eHW331 30003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27488112017508,"sku":"NNC4015X","price":54.76,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/teck90_bda06cae-5b20-4beb-8d3a-a92859d43924.png?v=1762459151"},{"product_id":"300-4-teck-90-bare-copper-aluminum-interlocked-armored-cable-with-ground-1kv","title":"300-4 Teck 90 Bare Copper Aluminum Interlocked Armored Cable With Ground 1KV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Teck_90_AL_1kv.pdf?v=1742394179\" width=\"\" height=\"\" type=\"application\/pdf\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e300-4 Teck 90 Bare Copper Aluminum Interlocked Armored Cable With Ground 1KV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eFor exposed or concealed wiring in wet or dry locations. For use in ventilated, non ventilated and ladder type cable troughs and ventilated flexible cableway in wet, dry, or hazardous locations. Sunlight Resistant. Typical applications are for control. lighting and power circuits in: pulp and paper mills, steel mills, food processing plants, commercial centers, mines, generating stations, refineries, industrial plants and chemical plants. Rated for 1000 lbs.\/FT maximum sidewall pressure. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e300-4 MCM \u003c\/span\u003eTeck 90 cable ,1KV armored cable,\u003cspan\u003e 300-4 MCM\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eBare copper interlocked cable, Aluminum armored cable, Teck 90 1KV rating,\u003cspan\u003e 300-4 MCM\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eInterlocked armored cable, Bare copper aluminum cable,\u003cspan\u003e 300-4 MCM\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eArmored electrical cable.\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eClass B stranded copper, compressed or compact, in accordance with ASTM B3 and B8.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCross-Linked Polyethylene (XLPE), Colour Code: 2\/C black, white; 3\/C red, black, blue; 4\/C red, black, blue, white For cables larger than No. 2 AWG or more than 4\/C, the insulation is black and numbered\u003cbr\u003e\u003cstrong\u003e• Grounding Conductors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUninsulated Class B stranded grounding conductor\u003cbr\u003e\u003cstrong\u003e• Inner Jacket:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBlack Polyvinyl Chloride (PVC)\u003cbr\u003e\u003cstrong\u003e• Armor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAluminum Interlocked Armour (AIA)\u003cbr\u003e\u003cstrong\u003e• Overall Jacket:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBlack PVC (optional colours available)\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA C22.2 No. 174 Cables in Hazardous Locations\u003cbr\u003e• CSA C22.2 No. 131 Type TECK 90 Cable\u003cbr\u003e• CSA C22.2 No. 2556 \u0026amp; No. 0.3 Wire and Cable Test Methods\u003cbr\u003e• CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating\u003cbr\u003e• CSA HL - for Hazardous Locations rating\u003cbr\u003e• CSA SUN RES - for Sunlight Resistant rating\u003cbr\u003e• CSA AG14 - Acid Gas Compliance\u003cbr\u003e• IEEE 383 Flame Test (70,000 btu)\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1000V Multi Conductor, 8AWG -1000 Kcmil Copper, FT4 - Flame Retardancy Rating, XLPE Insulation, Aluminum Interlocked Armour, Sunlight Resistant, -40°C - 90°C, Rated HL, AG14\u003cbr\u003e\u003cbr\u003e•  -40°C - CSA Cold Bend and Impact Temperature\u003cbr\u003e• -25°C - Min. Installation Temperature\u003cbr\u003e• 90°C - Max. Continuous Operating Temperature\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e300 MCM\u003cspan\u003e\u003cbr\u003e\u003cstrong\u003e• No of conductor: \u003c\/strong\u003e4\u003cbr\u003e\u003cstrong\u003e• No of Strands:\u003c\/strong\u003e 37\u003cbr\u003e\u003cstrong\u003e• Insulation thickness ( mil ): \u003c\/strong\u003e90\u003cbr\u003e\u003cstrong\u003e• Ground No x AWG:\u003c\/strong\u003e 1x4\u003cbr\u003e\u003cstrong\u003e• Inner Jacket thickness ( mil ):\u003c\/strong\u003e 115\u003cbr\u003e\u003cstrong\u003e• Dia. Over Armour ( Inch ):\u003c\/strong\u003e  2.498\u003cbr\u003e\u003cstrong\u003e• Overall Jacket thickness ( mil ):\u003c\/strong\u003e 65\u003cbr\u003e\u003cstrong\u003e• Approx. OD ( Inch ): \u003c\/strong\u003e 2.630\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (lb\/1000ft):\u003c\/strong\u003e 5527\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity In Raceway 90°C†:  \u003c\/strong\u003e256 Amp\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 391px; height: 78px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 381px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eHouston Wire \u0026amp; Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eHW331 30004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27488112083044,"sku":"NNC4016X","price":67.92,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/teck90_3a496ec2-0225-4797-81d9-1f1baf85fe3d.png?v=1762459152"},{"product_id":"350-4-teck-90-bare-copper-aluminum-interlocked-armored-cable-with-ground-1kv","title":"350-4 Teck 90 Bare Copper Aluminum Interlocked Armored Cable With Ground 1KV","description":"\u003cp\u003e[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Teck_90_AL_1kv.pdf?v=1742394179\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e350-4 Teck 90 Bare Copper Aluminum Interlocked Armored Cable With Ground 1KV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eFor exposed or concealed wiring in wet or dry locations. For use in ventilated, non ventilated and ladder type cable troughs and ventilated flexible cableway in wet, dry, or hazardous locations. Sunlight Resistant. Typical applications are for control. lighting and power circuits in: pulp and paper mills, steel mills, food processing plants, commercial centers, mines, generating stations, refineries, industrial plants and chemical plants. Rated for 1000 lbs.\/FT maximum sidewall pressure. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e350-4 MCM \u003c\/span\u003eTeck 90 cable ,1KV armored cable,\u003cspan\u003e 350-4 MCM\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eBare copper interlocked cable, Aluminum armored cable, Teck 90 1KV rating,\u003cspan\u003e 350-4 MCM\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eInterlocked armored cable, Bare copper aluminum cable,\u003cspan\u003e 350-4 MCM\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eArmored electrical cable.\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eClass B stranded copper, compressed or compact, in accordance with ASTM B3 and B8.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCross-Linked Polyethylene (XLPE), Colour Code: 2\/C black, white; 3\/C red, black, blue; 4\/C red, black, blue, white For cables larger than No. 2 AWG or more than 4\/C, the insulation is black and numbered\u003cbr\u003e\u003cstrong\u003e• Grounding Conductors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUninsulated Class B stranded grounding conductor\u003cbr\u003e\u003cstrong\u003e• Inner Jacket:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBlack Polyvinyl Chloride (PVC)\u003cbr\u003e\u003cstrong\u003e• Armor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAluminum Interlocked Armour (AIA)\u003cbr\u003e\u003cstrong\u003e• Overall Jacket:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBlack PVC (optional colours available)\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA C22.2 No. 174 Cables in Hazardous Locations\u003cbr\u003e• CSA C22.2 No. 131 Type TECK 90 Cable\u003cbr\u003e• CSA C22.2 No. 2556 \u0026amp; No. 0.3 Wire and Cable Test Methods\u003cbr\u003e• CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating\u003cbr\u003e• CSA HL - for Hazardous Locations rating\u003cbr\u003e• CSA SUN RES - for Sunlight Resistant rating\u003cbr\u003e• CSA AG14 - Acid Gas Compliance\u003cbr\u003e• IEEE 383 Flame Test (70,000 btu)\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1000V Multi Conductor, 8AWG -1000 Kcmil Copper, FT4 - Flame Retardancy Rating, XLPE Insulation, Aluminum Interlocked Armour, Sunlight Resistant, -40°C - 90°C, Rated HL, AG14\u003cbr\u003e\u003cbr\u003e•  -40°C - CSA Cold Bend and Impact Temperature\u003cbr\u003e• -25°C - Min. Installation Temperature\u003cbr\u003e• 90°C - Max. Continuous Operating Temperature\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e350 MCM\u003cspan\u003e\u003cbr\u003e\u003cstrong\u003e• No of conductor: \u003c\/strong\u003e4\u003cbr\u003e\u003cstrong\u003e• No of Strands:\u003c\/strong\u003e 37\u003cbr\u003e\u003cstrong\u003e• Insulation thickness ( mil ): \u003c\/strong\u003e90\u003cbr\u003e\u003cstrong\u003e• Ground No x AWG:\u003c\/strong\u003e 1x3\u003cbr\u003e\u003cstrong\u003e• Inner Jacket thickness ( mil ):\u003c\/strong\u003e 115\u003cbr\u003e\u003cstrong\u003e• Dia. Over Armour ( Inch ):\u003c\/strong\u003e 2.571\u003cbr\u003e\u003cstrong\u003e• Overall Jacket thickness ( mil ):\u003c\/strong\u003e 65\u003cbr\u003e\u003cstrong\u003e• Approx. OD ( Inch ): \u003c\/strong\u003e2.703\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (lb\/1000ft):\u003c\/strong\u003e 6242\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity In Raceway 90°C†:  \u003c\/strong\u003e280 Amp\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 391px; height: 62px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"width: 381px; height: 21px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.1406px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 22.1406px;\"\u003e\u003cstrong\u003eNexans :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 22.1406px;\"\u003e137893\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 185.469px;\"\u003e\u003cstrong\u003eService Wire Co :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px;\"\u003eCAAC350\/4U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 185.469px;\"\u003e\u003cstrong\u003eHouston Wire \u0026amp; Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px;\"\u003eHW331 35004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27488112148580,"sku":"NNC4017X","price":57.96,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/teck90_520a7c16-505c-42ad-bd3d-a25a87728d83.png?v=1762459152"},{"product_id":"500-4-teck-90-bare-copper-aluminum-interlocked-armored-cable-with-ground-1kv","title":"500-4 Teck 90 Bare Copper Aluminum Interlocked Armored Cable With Ground 1KV","description":"\u003cp\u003e[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Teck_90_AL_1kv.pdf?v=1742394179\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e500-4 Teck 90 Bare Copper Aluminum Interlocked Armored Cable With Ground 1KV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eFor exposed or concealed wiring in wet or dry locations. For use in ventilated, non ventilated and ladder type cable troughs and ventilated flexible cableway in wet, dry, or hazardous locations. Sunlight Resistant. Typical applications are for control. lighting and power circuits in: pulp and paper mills, steel mills, food processing plants, commercial centers, mines, generating stations, refineries, industrial plants and chemical plants. Rated for 1000 lbs.\/FT maximum sidewall pressure. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e500-4 MCM \u003c\/span\u003eTeck 90 cable ,1KV armored cable,\u003cspan\u003e 500-4 MCM\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eBare copper interlocked cable, Aluminum armored cable, Teck 90 1KV rating,\u003cspan\u003e 500-4 MCM\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eInterlocked armored cable, Bare copper aluminum cable,\u003cspan\u003e 500-4 MCM\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eArmored electrical cable.\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eClass B stranded copper, compressed or compact, in accordance with ASTM B3 and B8.\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCross-Linked Polyethylene (XLPE), Colour Code: 2\/C black, white; 3\/C red, black, blue; 4\/C red, black, blue, white For cables larger than No. 2 AWG or more than 4\/C, the insulation is black and numbered\u003cbr\u003e\u003cstrong\u003e• Grounding Conductors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUninsulated Class B stranded grounding conductor\u003cbr\u003e\u003cstrong\u003e• Inner Jacket:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBlack Polyvinyl Chloride (PVC)\u003cbr\u003e\u003cstrong\u003e• Armor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAluminum Interlocked Armour (AIA)\u003cbr\u003e\u003cstrong\u003e• Overall Jacket:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBlack PVC (optional colours available)\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA C22.2 No. 174 Cables in Hazardous Locations\u003cbr\u003e• CSA C22.2 No. 131 Type TECK 90 Cable\u003cbr\u003e• CSA C22.2 No. 2556 \u0026amp; No. 0.3 Wire and Cable Test Methods\u003cbr\u003e• CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating\u003cbr\u003e• CSA HL - for Hazardous Locations rating\u003cbr\u003e• CSA SUN RES - for Sunlight Resistant rating\u003cbr\u003e• CSA AG14 - Acid Gas Compliance\u003cbr\u003e• IEEE 383 Flame Test (70,000 btu)\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1000V Multi Conductor, 8AWG -1000 Kcmil Copper, FT4 - Flame Retardancy Rating, XLPE Insulation, Aluminum Interlocked Armour, Sunlight Resistant, -40°C - 90°C, Rated HL, AG14\u003cbr\u003e\u003cbr\u003e•  -40°C - CSA Cold Bend and Impact Temperature\u003cbr\u003e• -25°C - Min. Installation Temperature\u003cbr\u003e• 90°C - Max. Continuous Operating Temperature\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e500 MCM\u003cspan\u003e\u003cbr\u003e\u003cstrong\u003e• No of conductor: \u003c\/strong\u003e4\u003cbr\u003e\u003cstrong\u003e• No of Strands:\u003c\/strong\u003e 37\u003cbr\u003e\u003cstrong\u003e• Insulation thickness ( mil ): \u003c\/strong\u003e90\u003cbr\u003e\u003cstrong\u003e• Ground No x AWG:\u003c\/strong\u003e 1x3\u003cbr\u003e\u003cstrong\u003e• Inner Jacket thickness ( mil ):\u003c\/strong\u003e 115\u003cbr\u003e\u003cstrong\u003e• Dia. Over Armour ( Inch ):\u003c\/strong\u003e  2.872\u003cbr\u003e\u003cstrong\u003e• Overall Jacket thickness ( mil ):\u003c\/strong\u003e 65\u003cbr\u003e\u003cstrong\u003e• Approx. OD ( Inch ):\u003c\/strong\u003e 3.004\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (lb\/1000ft):\u003c\/strong\u003e 8351\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity In Raceway 90°C†:  \u003c\/strong\u003e344 Amp\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 391px; height: 81.5782px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"width: 381px; height: 21px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.125px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 22.125px;\"\u003e\u003cstrong\u003eNexans :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 22.125px;\"\u003e568345\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19.5938px;\"\u003e\u003cstrong\u003eService Wire Co :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19.5938px;\"\u003eCAAC500\/4U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 185.469px;\"\u003e\u003cstrong\u003eHouston Wire \u0026amp; Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px;\"\u003e\u003cspan\u003eHW331 50004\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27488115654756,"sku":"NNC4020X","price":65.88,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/teck90_59d183fe-84fd-44b2-bba4-febb729a6fe1.png?v=1762459154"},{"product_id":"16-awg-7c-unarmored-type-p-drilling-rig-marine-control-cable-600v-1kv","title":"16 AWG 7C Unarmored Type P Drilling Rig \u0026 Marine Control Cable 600V\/1kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/dmc-06-type-p-control.pdf?v=1740491827\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e16 AWG 7C Unarmored Type P Drilling Rig \u0026amp; Marine Control Cable 600V\/1kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• DRILMAR 125-XE cables are specifically designed for the installation and use in marine environments, for use on offshore drilling rigs, aboard marine vessels, and on fixed and floating offshore facilities where harsh marine environments exist. These cables are used in control, indicating, communication, electronic and similar circuits where multiple conductor cables are required.\u003cbr\u003e• Typical applications include: Driller’s console, fire and gas detection systems, bilge and ballast controls and general alarm systems\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e16 AWG 7C Type P Rig Cable, Type P Cable, 16 AWG 7C Type P Drilling Rig and Marine Cable, Rig Cable, 16 AWG 7C Type P Power Cable, Shipboard Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• IEEE 1580\u003cbr\u003e• Recommended Practice for Marine Cable for Use on Shipboard and Fixed and Floating Platforms.\u003cbr\u003e• IEEE 45\u003cbr\u003e• Recommended Practice for Electrical Installations on Shipboard Cable.\u003cbr\u003e• UL 1309\u003cbr\u003e• Marine Shipboard Cable.\u003cbr\u003e• CSA C22.2 No. 245\u003cbr\u003e• Marine Shipboard Cable.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eEngineered for easiest installation. Extra flexible stranding meets IEEE, UL, and CSA requirements.\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003eMaximum conductor operating temperature: 100 °C as Type P per IEEE, and 110°C as Type X110 per UL and CSA. Meets ampacity ratings per ABS, DNV, LRS, and TCMS. \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003eDRILMAR XLPO Insulation:\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Superior oil and chemical resistance.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Sunlight resistant.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Rated at 125 ºC.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Passes Cold Bend at -55 ºC.\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003eHeavy Duty CP Jacket:\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Arctic Type XE design.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Abrasion and sunlight resistant.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Rated at 90 ºC.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Completed cable offers superior flame resistance meeting:\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• 70,000 Btu Flame Tests IEEE 1202\/FT4, IEEE 383, UL 1685, ICEA T-30-820, and IEC 332 Category A.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• 210,000 Btu Flame Test ICEA T-29-520.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Arctic Type design meets Cold Bend and Impact Tests at -40 ºC, exceeding the Transport Canada Marine Safety requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003c\/strong\u003e\u003cspan\u003e Soft annealed flexible Tin Coated Copper per IEEE, UL, and CSA.\u003cbr\u003e\u003cstrong\u003e• Separator Tape:\u003c\/strong\u003e Polyester tape as required.\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Insulation:\u003c\/strong\u003e\u003cspan\u003e Flame retardant and sunlight resistant Crosslinked Polyolefin (XLPO) per IEEE. Also meets and exceeds the requirements of UL and CSA for Type X110. DRILMAR 125-XE is a 125 °C XLPO.\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Identification:\u003c\/strong\u003e\u003cspan\u003e Color coded insulation per IEEE, UL and CSA. \u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003cstrong\u003e• Assembly: \u003c\/strong\u003eConductors cabled round with\u003cstrong\u003e \u003c\/strong\u003emoisture and flame retardant fillers, as required and binder tape.\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003c\/strong\u003e\u003cspan\u003e Flame retardant and sunlight resistant Arctic Type Chlorinated Polyethylene (CPE) per IEEE, UL and CSA.\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Armor:\u003c\/strong\u003e\u003cspan\u003e Standard - Bronze.\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Overall Sheath (optional):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFlame retardant and sunlight resistant Arctic Type Chlorinated Polyethylene (CPE) per IEEE, UL, and CSA. \u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 16 AWG\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003cstrong\u003e• No. of Conductor:\u003c\/strong\u003e 7\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mils):\u003c\/strong\u003e 45\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mm):\u003c\/strong\u003e 1.22\u003cbr\u003e\u003cstrong\u003e• Nominal OD (in):\u003c\/strong\u003e 0.51\u003cbr\u003e\u003cstrong\u003e• Nominal OD (mm):\u003c\/strong\u003e 13.1\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Net Weight lb\/kft:\u003c\/strong\u003e 151\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv id=\"gtx-trans\" style=\"position: absolute; left: -20px; top: 865.833px;\"\u003e\n\u003cdiv class=\"gtx-trans-icon\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27521957920868,"sku":"NNCDC16PCPE-7","price":3.7,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/6_0ef81ebb-e960-4c7f-9bb2-24ee0e9554f2.png?v=1762459740"},{"product_id":"12-awg-20c-unarmored-type-p-drilling-rig-marine-control-cable-600v-1kv","title":"12 AWG 20C Unarmored Type P Drilling Rig \u0026 Marine Control Cable 600V\/1kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/dmc-06-type-p-control.pdf?v=1740491827\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 20C Unarmored Type P Drilling Rig \u0026amp; Marine Control Cable 600V\/1kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• DRILMAR 125-XE cables are specifically designed for the installation and use in marine environments, for use on offshore drilling rigs, aboard marine vessels, and on fixed and floating offshore facilities where harsh marine environments exist. These cables are used in control, indicating, communication, electronic and similar circuits where multiple conductor cables are required.\u003cbr\u003e• Typical applications include: Driller’s console, fire and gas detection systems, bilge and ballast controls and general alarm systems\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e12 AWG 20C Type P Rig Cable, Type P Cable, 12 AWG 20C Type P Drilling Rig and Marine Cable, Rig Cable, 12 AWG 20C Type P Power Cable, Shipboard Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• IEEE 1580\u003cbr\u003e• Recommended Practice for Marine Cable for Use on Shipboard and Fixed and Floating Platforms.\u003cbr\u003e• IEEE 45\u003cbr\u003e• Recommended Practice for Electrical Installations on Shipboard Cable.\u003cbr\u003e• UL 1309\u003cbr\u003e• Marine Shipboard Cable.\u003cbr\u003e• CSA C22.2 No. 245\u003cbr\u003e• Marine Shipboard Cable.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eEngineered for easiest installation. Extra flexible stranding meets IEEE, UL, and CSA requirements.\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003eMaximum conductor operating temperature: 100 °C as Type P per IEEE, and 110°C as Type X110 per UL and CSA. Meets ampacity ratings per ABS, DNV, LRS, and TCMS. \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003eDRILMAR XLPO Insulation:\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Superior oil and chemical resistance.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Sunlight resistant.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Rated at 125 ºC.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Passes Cold Bend at -55 ºC.\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003eHeavy Duty CP Jacket:\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Arctic Type XE design.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Abrasion and sunlight resistant.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Rated at 90 ºC.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Completed cable offers superior flame resistance meeting:\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• 70,000 Btu Flame Tests IEEE 1202\/FT4, IEEE 383, UL 1685, ICEA T-30-820, and IEC 332 Category A.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• 210,000 Btu Flame Test ICEA T-29-520.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Arctic Type design meets Cold Bend and Impact Tests at -40 ºC, exceeding the Transport Canada Marine Safety requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003c\/strong\u003e\u003cspan\u003e Soft annealed flexible Tin Coated Copper per IEEE, UL, and CSA.\u003cbr\u003e\u003cstrong\u003e• Separator Tape:\u003c\/strong\u003e Polyester tape as required.\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Insulation:\u003c\/strong\u003e\u003cspan\u003e Flame retardant and sunlight resistant Crosslinked Polyolefin (XLPO) per IEEE. Also meets and exceeds the requirements of UL and CSA for Type X110. DRILMAR 125-XE is a 125 °C XLPO.\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Identification:\u003c\/strong\u003e\u003cspan\u003e Color coded insulation per IEEE, UL and CSA. \u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003cstrong\u003e• Assembly: \u003c\/strong\u003eConductors cabled round with\u003cstrong\u003e \u003c\/strong\u003emoisture and flame retardant fillers, as required and binder tape.\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003c\/strong\u003e\u003cspan\u003e Flame retardant and sunlight resistant Arctic Type Chlorinated Polyethylene (CPE) per IEEE, UL and CSA.\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Armor:\u003c\/strong\u003e\u003cspan\u003e Standard - Bronze.\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Overall Sheath (optional):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFlame retardant and sunlight resistant Arctic Type Chlorinated Polyethylene (CPE) per IEEE, UL, and CSA. \u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 12 AWG\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003cstrong\u003e• No. of Conductor:\u003c\/strong\u003e 20\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mils):\u003c\/strong\u003e 80\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mm):\u003c\/strong\u003e 2.13\u003cbr\u003e\u003cstrong\u003e• Nominal OD (in):\u003c\/strong\u003e 1.07\u003cbr\u003e\u003cstrong\u003e• Nominal OD (mm):\u003c\/strong\u003e 27.1\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Net Weight lb\/kft:\u003c\/strong\u003e 780\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cdiv style=\"position: absolute; left: -19px; top: 865.833px;\" id=\"gtx-trans\"\u003e\n\u003cdiv class=\"gtx-trans-icon\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27521960509540,"sku":"NNCDC12PCPE-20","price":9.68,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/6_1ba01281-6176-47ed-a89b-1f8d6cb8b647.png?v=1762459740"},{"product_id":"202-14-2053-okonite-fmr-okolon-ts-cpe-1000v-16-awg-3-conductors","title":"202-14-2053 Okonite-FMR Okolon TS-CPE - 1000V - 16 AWG - 3 Conductors","description":"\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003cbr\u003e Okonite-FMR is Okonite’s trade name for its heat, moisture, flame and chemically resistant, mechanically rugged ethylene-propylene insulation compound. It is flame retardant and will pass both the 70,000 BTU\/hour and 210,000 BTU\/hour tray flame test. Its physical properties and flame retardency permit its use without a jacket on the single conductors thus providing a substantially smaller overall diameter control cable.\u003cbr\u003e The properties of Okonite-FMR insulation substantially enhance the well known features of ethylene propylene rubber insulations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket\u003c\/strong\u003e\u003cbr\u003e The overall Okolon TS-CPE jacket is a thermoset chlorinated polyethylene compound. This combination construction assures circuit security because of its high mechanical strength and excellent resistance to moisture, ozone, oil and most chemicals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003cbr\u003e Okonite-FMR Control Cables are recommended for use in either power generating plants and in substations; designed especially for critical circuits where continuity of service is of prime importance. This premium quality control cable is recommended for wet or dry, ac or dc service at conductor temperatures to 90°C. They may be installed in conduits, ducts, cable troughs, trays, messenger supported, or directly buried in the earth.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductors:\u003c\/strong\u003e Coated copper per ASTM B-33, Class B stranded per ASTM B-8.\u003cbr\u003e \u003cstrong\u003eInsulation: \u003c\/strong\u003eOkonite-FMR meets or exceeds the electrical and physical requirements of ICEA S-73-532.\u003cbr\u003e \u003cstrong\u003eColor Coding: \u003c\/strong\u003eBase colors and tracers per ICEA Method 1 Table E-1. Sequence shown on reverse of this sheet.\u003cbr\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled using flame and moisture resistant fillers.\u003cbr\u003e \u003cstrong\u003eOverall Jacket: \u003c\/strong\u003eThe Okolon TS-CPE compound meets or ex- ceeds the requirements of ICEA S-73-532\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFlame retardant - passes the IEEE 383 and 1202 flame test requirements. Also passes the ICEA T-29-520 (210,000 BTU\/hr) flame test.\u003c\/li\u003e\n\u003cli\u003eQuality Assurance traceability available on special order.\u003c\/li\u003e\n\u003cli\u003e90°C rated control cable, factory assembled for indoor or outdoor installation in cable trays, in raceways, direct burial in the earth, or supported by messenger wire.\u003c\/li\u003e\n\u003cli\u003eMechanically rugged.\u003c\/li\u003e\n\u003cli\u003eFlexible, easy to install and terminate.\u003c\/li\u003e\n\u003cli\u003eColor coded conductors.\u003c\/li\u003e\n\u003cli\u003eResistant to water, oil and most chemicals.\u003c\/li\u003e\n\u003cli\u003eThermally stable at elevated temperatures.\u003c\/li\u003e\n\u003cli\u003eHigh insulation resistance, even at elevated temperatures.\u003c\/li\u003e\n\u003cli\u003eSmall diameter, lightweight.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27552869187684,"sku":"NNC8191X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/okonite-fmrn-okolon_123_2f592d42-2977-42ee-9ce9-1b24b0c21792.jpg?v=1762461717"},{"product_id":"202-14-2054-okonite-fmr-okolon-ts-cpe-1000v-16-awg-4-conductors","title":"202-14-2054 Okonite-FMR Okolon TS-CPE - 1000V - 16 AWG - 4 Conductors","description":"\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003cbr\u003e Okonite-FMR is Okonite’s trade name for its heat, moisture, flame and chemically resistant, mechanically rugged ethylene-propylene insulation compound. It is flame retardant and will pass both the 70,000 BTU\/hour and 210,000 BTU\/hour tray flame test. Its physical properties and flame retardency permit its use without a jacket on the single conductors thus providing a substantially smaller overall diameter control cable.\u003cbr\u003e The properties of Okonite-FMR insulation substantially enhance the well known features of ethylene propylene rubber insulations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket\u003c\/strong\u003e\u003cbr\u003e The overall Okolon TS-CPE jacket is a thermoset chlorinated polyethylene compound. This combination construction assures circuit security because of its high mechanical strength and excellent resistance to moisture, ozone, oil and most chemicals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003cbr\u003e Okonite-FMR Control Cables are recommended for use in either power generating plants and in substations; designed especially for critical circuits where continuity of service is of prime importance. This premium quality control cable is recommended for wet or dry, ac or dc service at conductor temperatures to 90°C. They may be installed in conduits, ducts, cable troughs, trays, messenger supported, or directly buried in the earth.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductors:\u003c\/strong\u003e Coated copper per ASTM B-33, Class B stranded per ASTM B-8.\u003cbr\u003e \u003cstrong\u003eInsulation: \u003c\/strong\u003eOkonite-FMR meets or exceeds the electrical and physical requirements of ICEA S-73-532.\u003cbr\u003e \u003cstrong\u003eColor Coding: \u003c\/strong\u003eBase colors and tracers per ICEA Method 1 Table E-1. Sequence shown on reverse of this sheet.\u003cbr\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled using flame and moisture resistant fillers.\u003cbr\u003e \u003cstrong\u003eOverall Jacket: \u003c\/strong\u003eThe Okolon TS-CPE compound meets or ex- ceeds the requirements of ICEA S-73-532\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFlame retardant - passes the IEEE 383 and 1202 flame test requirements. Also passes the ICEA T-29-520 (210,000 BTU\/hr) flame test.\u003c\/li\u003e\n\u003cli\u003eQuality Assurance traceability available on special order.\u003c\/li\u003e\n\u003cli\u003e90°C rated control cable, factory assembled for indoor or outdoor installation in cable trays, in raceways, direct burial in the earth, or supported by messenger wire.\u003c\/li\u003e\n\u003cli\u003eMechanically rugged.\u003c\/li\u003e\n\u003cli\u003eFlexible, easy to install and terminate.\u003c\/li\u003e\n\u003cli\u003eColor coded conductors.\u003c\/li\u003e\n\u003cli\u003eResistant to water, oil and most chemicals.\u003c\/li\u003e\n\u003cli\u003eThermally stable at elevated temperatures.\u003c\/li\u003e\n\u003cli\u003eHigh insulation resistance, even at elevated temperatures.\u003c\/li\u003e\n\u003cli\u003eSmall diameter, lightweight.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27552869974116,"sku":"NNC8192X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/okonite-fmrn-okolon_123_7d427515-877b-4fba-b6d6-3d3febb0a1ef.jpg?v=1762461718"},{"product_id":"202-14-2055-okonite-fmr-okolon-ts-cpe-1000v-16-awg-5-conductors","title":"202-14-2055 Okonite-FMR Okolon TS-CPE - 1000V - 16 AWG - 5 Conductors","description":"\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003cbr\u003e Okonite-FMR is Okonite’s trade name for its heat, moisture, flame and chemically resistant, mechanically rugged ethylene-propylene insulation compound. It is flame retardant and will pass both the 70,000 BTU\/hour and 210,000 BTU\/hour tray flame test. Its physical properties and flame retardency permit its use without a jacket on the single conductors thus providing a substantially smaller overall diameter control cable.\u003cbr\u003e The properties of Okonite-FMR insulation substantially enhance the well known features of ethylene propylene rubber insulations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket\u003c\/strong\u003e\u003cbr\u003e The overall Okolon TS-CPE jacket is a thermoset chlorinated polyethylene compound. This combination construction assures circuit security because of its high mechanical strength and excellent resistance to moisture, ozone, oil and most chemicals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003cbr\u003e Okonite-FMR Control Cables are recommended for use in either power generating plants and in substations; designed especially for critical circuits where continuity of service is of prime importance. This premium quality control cable is recommended for wet or dry, ac or dc service at conductor temperatures to 90°C. They may be installed in conduits, ducts, cable troughs, trays, messenger supported, or directly buried in the earth.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductors:\u003c\/strong\u003e Coated copper per ASTM B-33, Class B stranded per ASTM B-8.\u003cbr\u003e \u003cstrong\u003eInsulation: \u003c\/strong\u003eOkonite-FMR meets or exceeds the electrical and physical requirements of ICEA S-73-532.\u003cbr\u003e \u003cstrong\u003eColor Coding: \u003c\/strong\u003eBase colors and tracers per ICEA Method 1 Table E-1. Sequence shown on reverse of this sheet.\u003cbr\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled using flame and moisture resistant fillers.\u003cbr\u003e \u003cstrong\u003eOverall Jacket: \u003c\/strong\u003eThe Okolon TS-CPE compound meets or ex- ceeds the requirements of ICEA S-73-532\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFlame retardant - passes the IEEE 383 and 1202 flame test requirements. Also passes the ICEA T-29-520 (210,000 BTU\/hr) flame test.\u003c\/li\u003e\n\u003cli\u003eQuality Assurance traceability available on special order.\u003c\/li\u003e\n\u003cli\u003e90°C rated control cable, factory assembled for indoor or outdoor installation in cable trays, in raceways, direct burial in the earth, or supported by messenger wire.\u003c\/li\u003e\n\u003cli\u003eMechanically rugged.\u003c\/li\u003e\n\u003cli\u003eFlexible, easy to install and terminate.\u003c\/li\u003e\n\u003cli\u003eColor coded conductors.\u003c\/li\u003e\n\u003cli\u003eResistant to water, oil and most chemicals.\u003c\/li\u003e\n\u003cli\u003eThermally stable at elevated temperatures.\u003c\/li\u003e\n\u003cli\u003eHigh insulation resistance, even at elevated temperatures.\u003c\/li\u003e\n\u003cli\u003eSmall diameter, lightweight.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27552870072420,"sku":"NNC8193X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/okonite-fmrn-okolon_123_5bf4ca6e-9dba-40e0-a574-46b28601b4fa.jpg?v=1759805466"},{"product_id":"202-14-2057-okonite-fmr-okolon-ts-cpe-1000v-16-awg-7-conductors","title":"202-14-2057 Okonite-FMR Okolon TS-CPE - 1000V - 16 AWG - 7 Conductors","description":"\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003cbr\u003e Okonite-FMR is Okonite’s trade name for its heat, moisture, flame and chemically resistant, mechanically rugged ethylene-propylene insulation compound. It is flame retardant and will pass both the 70,000 BTU\/hour and 210,000 BTU\/hour tray flame test. Its physical properties and flame retardency permit its use without a jacket on the single conductors thus providing a substantially smaller overall diameter control cable.\u003cbr\u003e The properties of Okonite-FMR insulation substantially enhance the well known features of ethylene propylene rubber insulations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket\u003c\/strong\u003e\u003cbr\u003e The overall Okolon TS-CPE jacket is a thermoset chlorinated polyethylene compound. This combination construction assures circuit security because of its high mechanical strength and excellent resistance to moisture, ozone, oil and most chemicals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003cbr\u003e Okonite-FMR Control Cables are recommended for use in either power generating plants and in substations; designed especially for critical circuits where continuity of service is of prime importance. This premium quality control cable is recommended for wet or dry, ac or dc service at conductor temperatures to 90°C. They may be installed in conduits, ducts, cable troughs, trays, messenger supported, or directly buried in the earth.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductors:\u003c\/strong\u003e Coated copper per ASTM B-33, Class B stranded per ASTM B-8.\u003cbr\u003e \u003cstrong\u003eInsulation: \u003c\/strong\u003eOkonite-FMR meets or exceeds the electrical and physical requirements of ICEA S-73-532.\u003cbr\u003e \u003cstrong\u003eColor Coding: \u003c\/strong\u003eBase colors and tracers per ICEA Method 1 Table E-1. Sequence shown on reverse of this sheet.\u003cbr\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled using flame and moisture resistant fillers.\u003cbr\u003e \u003cstrong\u003eOverall Jacket: \u003c\/strong\u003eThe Okolon TS-CPE compound meets or ex- ceeds the requirements of ICEA S-73-532\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFlame retardant - passes the IEEE 383 and 1202 flame test requirements. Also passes the ICEA T-29-520 (210,000 BTU\/hr) flame test.\u003c\/li\u003e\n\u003cli\u003eQuality Assurance traceability available on special order.\u003c\/li\u003e\n\u003cli\u003e90°C rated control cable, factory assembled for indoor or outdoor installation in cable trays, in raceways, direct burial in the earth, or supported by messenger wire.\u003c\/li\u003e\n\u003cli\u003eMechanically rugged.\u003c\/li\u003e\n\u003cli\u003eFlexible, easy to install and terminate.\u003c\/li\u003e\n\u003cli\u003eColor coded conductors.\u003c\/li\u003e\n\u003cli\u003eResistant to water, oil and most chemicals.\u003c\/li\u003e\n\u003cli\u003eThermally stable at elevated temperatures.\u003c\/li\u003e\n\u003cli\u003eHigh insulation resistance, even at elevated temperatures.\u003c\/li\u003e\n\u003cli\u003eSmall diameter, lightweight.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27552870137956,"sku":"NNC8194X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/okonite-fmrn-okolon_123_e3e39e4c-27d5-477d-8494-76f0a7c10b48.jpg?v=1762461720"},{"product_id":"202-14-2059-okonite-fmr-okolon-ts-cpe-1000v-16-awg-9-conductors","title":"202-14-2059 Okonite-FMR Okolon TS-CPE - 1000V - 16 AWG - 9 Conductors","description":"\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003cbr\u003e Okonite-FMR is Okonite’s trade name for its heat, moisture, flame and chemically resistant, mechanically rugged ethylene-propylene insulation compound. It is flame retardant and will pass both the 70,000 BTU\/hour and 210,000 BTU\/hour tray flame test. Its physical properties and flame retardency permit its use without a jacket on the single conductors thus providing a substantially smaller overall diameter control cable.\u003cbr\u003e The properties of Okonite-FMR insulation substantially enhance the well known features of ethylene propylene rubber insulations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket\u003c\/strong\u003e\u003cbr\u003e The overall Okolon TS-CPE jacket is a thermoset chlorinated polyethylene compound. This combination construction assures circuit security because of its high mechanical strength and excellent resistance to moisture, ozone, oil and most chemicals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003cbr\u003e Okonite-FMR Control Cables are recommended for use in either power generating plants and in substations; designed especially for critical circuits where continuity of service is of prime importance. This premium quality control cable is recommended for wet or dry, ac or dc service at conductor temperatures to 90°C. They may be installed in conduits, ducts, cable troughs, trays, messenger supported, or directly buried in the earth.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductors:\u003c\/strong\u003e Coated copper per ASTM B-33, Class B stranded per ASTM B-8.\u003cbr\u003e \u003cstrong\u003eInsulation: \u003c\/strong\u003eOkonite-FMR meets or exceeds the electrical and physical requirements of ICEA S-73-532.\u003cbr\u003e \u003cstrong\u003eColor Coding: \u003c\/strong\u003eBase colors and tracers per ICEA Method 1 Table E-1. Sequence shown on reverse of this sheet.\u003cbr\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled using flame and moisture resistant fillers.\u003cbr\u003e \u003cstrong\u003eOverall Jacket: \u003c\/strong\u003eThe Okolon TS-CPE compound meets or ex- ceeds the requirements of ICEA S-73-532\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFlame retardant - passes the IEEE 383 and 1202 flame test requirements. Also passes the ICEA T-29-520 (210,000 BTU\/hr) flame test.\u003c\/li\u003e\n\u003cli\u003eQuality Assurance traceability available on special order.\u003c\/li\u003e\n\u003cli\u003e90°C rated control cable, factory assembled for indoor or outdoor installation in cable trays, in raceways, direct burial in the earth, or supported by messenger wire.\u003c\/li\u003e\n\u003cli\u003eMechanically rugged.\u003c\/li\u003e\n\u003cli\u003eFlexible, easy to install and terminate.\u003c\/li\u003e\n\u003cli\u003eColor coded conductors.\u003c\/li\u003e\n\u003cli\u003eResistant to water, oil and most chemicals.\u003c\/li\u003e\n\u003cli\u003eThermally stable at elevated temperatures.\u003c\/li\u003e\n\u003cli\u003eHigh insulation resistance, even at elevated temperatures.\u003c\/li\u003e\n\u003cli\u003eSmall diameter, lightweight.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27552870203492,"sku":"NNC8195X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/okonite-fmrn-okolon_123_f56e746f-93e5-41cf-8bef-8d4754c953b1.jpg?v=1762461720"},{"product_id":"202-14-2062-okonite-fmr-okolon-ts-cpe-1000v-16-awg-12-conductors","title":"202-14-2062 Okonite-FMR Okolon TS-CPE - 1000V - 16 AWG - 12 Conductors","description":"\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003cbr\u003e Okonite-FMR is Okonite’s trade name for its heat, moisture, flame and chemically resistant, mechanically rugged ethylene-propylene insulation compound. It is flame retardant and will pass both the 70,000 BTU\/hour and 210,000 BTU\/hour tray flame test. Its physical properties and flame retardency permit its use without a jacket on the single conductors thus providing a substantially smaller overall diameter control cable.\u003cbr\u003e The properties of Okonite-FMR insulation substantially enhance the well known features of ethylene propylene rubber insulations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket\u003c\/strong\u003e\u003cbr\u003e The overall Okolon TS-CPE jacket is a thermoset chlorinated polyethylene compound. This combination construction assures circuit security because of its high mechanical strength and excellent resistance to moisture, ozone, oil and most chemicals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003cbr\u003e Okonite-FMR Control Cables are recommended for use in either power generating plants and in substations; designed especially for critical circuits where continuity of service is of prime importance. This premium quality control cable is recommended for wet or dry, ac or dc service at conductor temperatures to 90°C. They may be installed in conduits, ducts, cable troughs, trays, messenger supported, or directly buried in the earth.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductors:\u003c\/strong\u003e Coated copper per ASTM B-33, Class B stranded per ASTM B-8.\u003cbr\u003e \u003cstrong\u003eInsulation: \u003c\/strong\u003eOkonite-FMR meets or exceeds the electrical and physical requirements of ICEA S-73-532.\u003cbr\u003e \u003cstrong\u003eColor Coding: \u003c\/strong\u003eBase colors and tracers per ICEA Method 1 Table E-1. Sequence shown on reverse of this sheet.\u003cbr\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled using flame and moisture resistant fillers.\u003cbr\u003e \u003cstrong\u003eOverall Jacket: \u003c\/strong\u003eThe Okolon TS-CPE compound meets or ex- ceeds the requirements of ICEA S-73-532\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFlame retardant - passes the IEEE 383 and 1202 flame test requirements. Also passes the ICEA T-29-520 (210,000 BTU\/hr) flame test.\u003c\/li\u003e\n\u003cli\u003eQuality Assurance traceability available on special order.\u003c\/li\u003e\n\u003cli\u003e90°C rated control cable, factory assembled for indoor or outdoor installation in cable trays, in raceways, direct burial in the earth, or supported by messenger wire.\u003c\/li\u003e\n\u003cli\u003eMechanically rugged.\u003c\/li\u003e\n\u003cli\u003eFlexible, easy to install and terminate.\u003c\/li\u003e\n\u003cli\u003eColor coded conductors.\u003c\/li\u003e\n\u003cli\u003eResistant to water, oil and most chemicals.\u003c\/li\u003e\n\u003cli\u003eThermally stable at elevated temperatures.\u003c\/li\u003e\n\u003cli\u003eHigh insulation resistance, even at elevated temperatures.\u003c\/li\u003e\n\u003cli\u003eSmall diameter, lightweight.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27552870236260,"sku":"NNC8196X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/okonite-fmrn-okolon_123_2720ad71-66d3-4470-84c3-cdf8d39d148a.jpg?v=1762461721"},{"product_id":"202-14-2069-okonite-fmr-okolon-ts-cpe-1000v-16-awg-19-conductors","title":"202-14-2069 Okonite-FMR Okolon TS-CPE - 1000V - 16 AWG - 19 Conductors","description":"\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003cbr\u003e Okonite-FMR is Okonite’s trade name for its heat, moisture, flame and chemically resistant, mechanically rugged ethylene-propylene insulation compound. It is flame retardant and will pass both the 70,000 BTU\/hour and 210,000 BTU\/hour tray flame test. Its physical properties and flame retardency permit its use without a jacket on the single conductors thus providing a substantially smaller overall diameter control cable.\u003cbr\u003e The properties of Okonite-FMR insulation substantially enhance the well known features of ethylene propylene rubber insulations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket\u003c\/strong\u003e\u003cbr\u003e The overall Okolon TS-CPE jacket is a thermoset chlorinated polyethylene compound. This combination construction assures circuit security because of its high mechanical strength and excellent resistance to moisture, ozone, oil and most chemicals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003cbr\u003e Okonite-FMR Control Cables are recommended for use in either power generating plants and in substations; designed especially for critical circuits where continuity of service is of prime importance. This premium quality control cable is recommended for wet or dry, ac or dc service at conductor temperatures to 90°C. They may be installed in conduits, ducts, cable troughs, trays, messenger supported, or directly buried in the earth.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductors:\u003c\/strong\u003e Coated copper per ASTM B-33, Class B stranded per ASTM B-8.\u003cbr\u003e \u003cstrong\u003eInsulation: \u003c\/strong\u003eOkonite-FMR meets or exceeds the electrical and physical requirements of ICEA S-73-532.\u003cbr\u003e \u003cstrong\u003eColor Coding: \u003c\/strong\u003eBase colors and tracers per ICEA Method 1 Table E-1. Sequence shown on reverse of this sheet.\u003cbr\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled using flame and moisture resistant fillers.\u003cbr\u003e \u003cstrong\u003eOverall Jacket: \u003c\/strong\u003eThe Okolon TS-CPE compound meets or ex- ceeds the requirements of ICEA S-73-532\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFlame retardant - passes the IEEE 383 and 1202 flame test requirements. Also passes the ICEA T-29-520 (210,000 BTU\/hr) flame test.\u003c\/li\u003e\n\u003cli\u003eQuality Assurance traceability available on special order.\u003c\/li\u003e\n\u003cli\u003e90°C rated control cable, factory assembled for indoor or outdoor installation in cable trays, in raceways, direct burial in the earth, or supported by messenger wire.\u003c\/li\u003e\n\u003cli\u003eMechanically rugged.\u003c\/li\u003e\n\u003cli\u003eFlexible, easy to install and terminate.\u003c\/li\u003e\n\u003cli\u003eColor coded conductors.\u003c\/li\u003e\n\u003cli\u003eResistant to water, oil and most chemicals.\u003c\/li\u003e\n\u003cli\u003eThermally stable at elevated temperatures.\u003c\/li\u003e\n\u003cli\u003eHigh insulation resistance, even at elevated temperatures.\u003c\/li\u003e\n\u003cli\u003eSmall diameter, lightweight.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27552870301796,"sku":"NNC8197X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/okonite-fmrn-okolon_123_81ac009c-d7cb-4b67-8276-9443113ce870.jpg?v=1762461721"},{"product_id":"202-14-2087-okonite-fmr-okolon-ts-cpe-1000v-16-awg-37-conductors","title":"202-14-2087 Okonite-FMR Okolon TS-CPE - 1000V - 16 AWG - 37 Conductors","description":"\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003cbr\u003e Okonite-FMR is Okonite’s trade name for its heat, moisture, flame and chemically resistant, mechanically rugged ethylene-propylene insulation compound. It is flame retardant and will pass both the 70,000 BTU\/hour and 210,000 BTU\/hour tray flame test. Its physical properties and flame retardency permit its use without a jacket on the single conductors thus providing a substantially smaller overall diameter control cable.\u003cbr\u003e The properties of Okonite-FMR insulation substantially enhance the well known features of ethylene propylene rubber insulations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket\u003c\/strong\u003e\u003cbr\u003e The overall Okolon TS-CPE jacket is a thermoset chlorinated polyethylene compound. This combination construction assures circuit security because of its high mechanical strength and excellent resistance to moisture, ozone, oil and most chemicals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003cbr\u003e Okonite-FMR Control Cables are recommended for use in either power generating plants and in substations; designed especially for critical circuits where continuity of service is of prime importance. This premium quality control cable is recommended for wet or dry, ac or dc service at conductor temperatures to 90°C. They may be installed in conduits, ducts, cable troughs, trays, messenger supported, or directly buried in the earth.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductors:\u003c\/strong\u003e Coated copper per ASTM B-33, Class B stranded per ASTM B-8.\u003cbr\u003e \u003cstrong\u003eInsulation: \u003c\/strong\u003eOkonite-FMR meets or exceeds the electrical and physical requirements of ICEA S-73-532.\u003cbr\u003e \u003cstrong\u003eColor Coding: \u003c\/strong\u003eBase colors and tracers per ICEA Method 1 Table E-1. Sequence shown on reverse of this sheet.\u003cbr\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled using flame and moisture resistant fillers.\u003cbr\u003e \u003cstrong\u003eOverall Jacket: \u003c\/strong\u003eThe Okolon TS-CPE compound meets or ex- ceeds the requirements of ICEA S-73-532\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFlame retardant - passes the IEEE 383 and 1202 flame test requirements. Also passes the ICEA T-29-520 (210,000 BTU\/hr) flame test.\u003c\/li\u003e\n\u003cli\u003eQuality Assurance traceability available on special order.\u003c\/li\u003e\n\u003cli\u003e90°C rated control cable, factory assembled for indoor or outdoor installation in cable trays, in raceways, direct burial in the earth, or supported by messenger wire.\u003c\/li\u003e\n\u003cli\u003eMechanically rugged.\u003c\/li\u003e\n\u003cli\u003eFlexible, easy to install and terminate.\u003c\/li\u003e\n\u003cli\u003eColor coded conductors.\u003c\/li\u003e\n\u003cli\u003eResistant to water, oil and most chemicals.\u003c\/li\u003e\n\u003cli\u003eThermally stable at elevated temperatures.\u003c\/li\u003e\n\u003cli\u003eHigh insulation resistance, even at elevated temperatures.\u003c\/li\u003e\n\u003cli\u003eSmall diameter, lightweight.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27552870400100,"sku":"NNC8198X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/okonite-fmrn-okolon_123_577d5fb3-9e2a-46f2-8a2f-af4042a9ad71.jpg?v=1762461722"},{"product_id":"okonite-fmr-okolon-ts-cpe-1000v","title":"Okonite-FMR Okolon TS-CPE - 1000V","description":"[short]\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003cbr\u003e\nOkonite-FMR Control Cables are recommended for use in either power generating plants and in substations; designed especially for critical circuits where continuity of service is of prime importance. This premium quality control cable is recommended for wet or dry, ac or dc service at conductor temperatures to 90°C. They may be installed in conduits, ducts, cable troughs, trays, messenger supported, or directly buried in the earth.\u003c\/p\u003e\n[\/short]\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003cbr\u003e Okonite-FMR is Okonite’s trade name for its heat, moisture, flame and chemically resistant, mechanically rugged ethylene-propylene insulation compound. It is flame retardant and will pass both the 70,000 BTU\/hour and 210,000 BTU\/hour tray flame test. Its physical properties and flame retardency permit its use without a jacket on the single conductors thus providing a substantially smaller overall diameter control cable.\u003cbr\u003e The properties of Okonite-FMR insulation substantially enhance the well known features of ethylene propylene rubber insulations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket\u003c\/strong\u003e\u003cbr\u003e The overall Okolon TS-CPE jacket is a thermoset chlorinated polyethylene compound. This combination construction assures circuit security because of its high mechanical strength and excellent resistance to moisture, ozone, oil and most chemicals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductors:\u003c\/strong\u003e Coated copper per ASTM B-33, Class B stranded per ASTM B-8.\u003cbr\u003e \u003cstrong\u003eInsulation: \u003c\/strong\u003eOkonite-FMR meets or exceeds the electrical and physical requirements of ICEA S-73-532.\u003cbr\u003e \u003cstrong\u003eColor Coding: \u003c\/strong\u003eBase colors and tracers per ICEA Method 1 Table E-1. Sequence shown on reverse of this sheet.\u003cbr\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled using flame and moisture resistant fillers.\u003cbr\u003e \u003cstrong\u003eOverall Jacket: \u003c\/strong\u003eThe Okolon TS-CPE compound meets or ex- ceeds the requirements of ICEA S-73-532\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFlame retardant - passes the IEEE 383 and 1202 flame test requirements. Also passes the ICEA T-29-520 (210,000 BTU\/hr) flame test.\u003c\/li\u003e\n\u003cli\u003eQuality Assurance traceability available on special order.\u003c\/li\u003e\n\u003cli\u003e90°C rated control cable, factory assembled for indoor or outdoor installation in cable trays, in raceways, direct burial in the earth, or supported by messenger wire.\u003c\/li\u003e\n\u003cli\u003eMechanically rugged.\u003c\/li\u003e\n\u003cli\u003eFlexible, easy to install and terminate.\u003c\/li\u003e\n\u003cli\u003eColor coded conductors.\u003c\/li\u003e\n\u003cli\u003eResistant to water, oil and most chemicals.\u003c\/li\u003e\n\u003cli\u003eThermally stable at elevated temperatures.\u003c\/li\u003e\n\u003cli\u003eHigh insulation resistance, even at elevated temperatures.\u003c\/li\u003e\n\u003cli\u003eSmall diameter, lightweight.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27552870432868,"sku":"NNC8199X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/okonite-fmrn-okolon_123_c5d0ffc8-d5d1-4567-acb9-fd622ed78b32.jpg?v=1762461722"},{"product_id":"202-14-6053-okonite-fmr-lcs-okolon-ts-cpe-1000v-16-awg-3-conductors","title":"202-14-6053 Okonite-FMR-LCS Okolon TS-CPE - 1000V - 16 AWG - 3 Conductors","description":"\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003cbr\u003e Okonite-FMR is Okonite’s trade name for its heat, moisture, flame and chemically resistant, mechanically rugged ethylene-propylene insulation compound. It is flame retardant and will pass both the 70,000 BTU\/hour and 210,000 BTU\/hour tray flame test. Its physical properties and flame retardency permit its use without a jacket on the single conductors thus providing a substantially smaller overall diameter control cable.\u003cbr\u003e The properties of Okonite-FMR insulation substantially enhance the well known features of ethylene propylene rubber insulations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield\u003c\/strong\u003e\u003cbr\u003e The shield system consists of a 5 mil copper tape which is longitudinally applied over the extruded belt and fill. The Longitudinal Corrugated Shield (LCS) maintains uniformly low resistance and a low reactance path for optimum shielding against external high frequency interference.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket\u003c\/strong\u003e\u003cbr\u003e The Okolon TS-CPE jacket is a thermoset chlorinated polyethylene compound. This combination construction assures circuit security because of its high mechanical strength and excellent resistance to moisture, ozone, oil and most chemicals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003cbr\u003e Okonite-FMR Control Cables are recommended for use in either power generating plants and in substations; designed especially for critical circuits where continuity of service is of prime importance. This premium quality control cable is recommended for wet or dry, ac or dc service at conductor temperatures to 90°C. They may be installed in conduits, ducts, cable troughs, trays, messenger supported, or directly buried in the earth.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductors:\u003c\/strong\u003e Coated copper per ASTM B-33, Class B stranded per ASTM B-8.\u003cbr\u003e \u003cstrong\u003eInsulation: \u003c\/strong\u003eOkonite-FMR meets or exceeds the electrical and physical requirements of ICEA S-73-532.\u003cbr\u003e \u003cstrong\u003eColor Coding: \u003c\/strong\u003eBase colors and tracers per ICEA Method 1 Table E-1. Sequence shown on reverse of this sheet.\u003cbr\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled using flame and moisture resistant fillers.\u003cbr\u003e \u003cstrong\u003eShield: \u003c\/strong\u003eA 5 mil corrugated copper tape, longitudinally applied.\u003cbr\u003e \u003cstrong\u003eOverall Jacket: \u003c\/strong\u003eThe Okolon TS-CPE compound meets or ex- ceeds the requirements of ICEA S-73-532\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFlame retardant - passes the IEEE 383 and 1202 flame test requirements. Also passes the ICEA T-29-520 (210,000 BTU\/hr) flame test.\u003c\/li\u003e\n\u003cli\u003eQuality Assurance traceability available on special order.\u003c\/li\u003e\n\u003cli\u003e90°C rated control cable, factory assembled for indoor or outdoor installation in cable trays, in raceways, direct burial in the earth, or supported by messenger wire.\u003c\/li\u003e\n\u003cli\u003eMechanically rugged.\u003c\/li\u003e\n\u003cli\u003eFlexible, easy to install and terminate.\u003c\/li\u003e\n\u003cli\u003eColor coded conductors.\u003c\/li\u003e\n\u003cli\u003eResistant to water, oil and most chemicals.\u003c\/li\u003e\n\u003cli\u003eThermally stable at elevated temperatures.\u003c\/li\u003e\n\u003cli\u003eHigh insulation resistance, even at elevated temperatures.\u003c\/li\u003e\n\u003cli\u003eSmall diameter, lightweight.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27552879312996,"sku":"NNC8233X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/okonite-fmr-lcs_41_bf0f5615-d0e4-4e30-a51e-ac9e3a780a5b.jpg?v=1762461746"},{"product_id":"202-14-6054-okonite-fmr-lcs-okolon-ts-cpe-1000v-16-awg-4-conductors","title":"202-14-6054 Okonite-FMR-LCS Okolon TS-CPE - 1000V - 16 AWG - 4 Conductors","description":"\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003cbr\u003e Okonite-FMR is Okonite’s trade name for its heat, moisture, flame and chemically resistant, mechanically rugged ethylene-propylene insulation compound. It is flame retardant and will pass both the 70,000 BTU\/hour and 210,000 BTU\/hour tray flame test. Its physical properties and flame retardency permit its use without a jacket on the single conductors thus providing a substantially smaller overall diameter control cable.\u003cbr\u003e The properties of Okonite-FMR insulation substantially enhance the well known features of ethylene propylene rubber insulations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield\u003c\/strong\u003e\u003cbr\u003e The shield system consists of a 5 mil copper tape which is longitudinally applied over the extruded belt and fill. The Longitudinal Corrugated Shield (LCS) maintains uniformly low resistance and a low reactance path for optimum shielding against external high frequency interference.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket\u003c\/strong\u003e\u003cbr\u003e The Okolon TS-CPE jacket is a thermoset chlorinated polyethylene compound. This combination construction assures circuit security because of its high mechanical strength and excellent resistance to moisture, ozone, oil and most chemicals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003cbr\u003e Okonite-FMR Control Cables are recommended for use in either power generating plants and in substations; designed especially for critical circuits where continuity of service is of prime importance. This premium quality control cable is recommended for wet or dry, ac or dc service at conductor temperatures to 90°C. They may be installed in conduits, ducts, cable troughs, trays, messenger supported, or directly buried in the earth.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductors:\u003c\/strong\u003e Coated copper per ASTM B-33, Class B stranded per ASTM B-8.\u003cbr\u003e \u003cstrong\u003eInsulation: \u003c\/strong\u003eOkonite-FMR meets or exceeds the electrical and physical requirements of ICEA S-73-532.\u003cbr\u003e \u003cstrong\u003eColor Coding: \u003c\/strong\u003eBase colors and tracers per ICEA Method 1 Table E-1. Sequence shown on reverse of this sheet.\u003cbr\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled using flame and moisture resistant fillers.\u003cbr\u003e \u003cstrong\u003eShield: \u003c\/strong\u003eA 5 mil corrugated copper tape, longitudinally applied.\u003cbr\u003e \u003cstrong\u003eOverall Jacket: \u003c\/strong\u003eThe Okolon TS-CPE compound meets or ex- ceeds the requirements of ICEA S-73-532\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFlame retardant - passes the IEEE 383 and 1202 flame test requirements. Also passes the ICEA T-29-520 (210,000 BTU\/hr) flame test.\u003c\/li\u003e\n\u003cli\u003eQuality Assurance traceability available on special order.\u003c\/li\u003e\n\u003cli\u003e90°C rated control cable, factory assembled for indoor or outdoor installation in cable trays, in raceways, direct burial in the earth, or supported by messenger wire.\u003c\/li\u003e\n\u003cli\u003eMechanically rugged.\u003c\/li\u003e\n\u003cli\u003eFlexible, easy to install and terminate.\u003c\/li\u003e\n\u003cli\u003eColor coded conductors.\u003c\/li\u003e\n\u003cli\u003eResistant to water, oil and most chemicals.\u003c\/li\u003e\n\u003cli\u003eThermally stable at elevated temperatures.\u003c\/li\u003e\n\u003cli\u003eHigh insulation resistance, even at elevated temperatures.\u003c\/li\u003e\n\u003cli\u003eSmall diameter, lightweight.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27552879378532,"sku":"NNC8234X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/okonite-fmr-lcs_41_6096cab9-44d5-48fc-a822-e3620ead2dab.jpg?v=1762461747"},{"product_id":"202-14-6055-okonite-fmr-lcs-okolon-ts-cpe-1000v-16-awg-5-conductors","title":"202-14-6055 Okonite-FMR-LCS Okolon TS-CPE - 1000V - 16 AWG - 5 Conductors","description":"\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003cbr\u003e Okonite-FMR is Okonite’s trade name for its heat, moisture, flame and chemically resistant, mechanically rugged ethylene-propylene insulation compound. It is flame retardant and will pass both the 70,000 BTU\/hour and 210,000 BTU\/hour tray flame test. Its physical properties and flame retardency permit its use without a jacket on the single conductors thus providing a substantially smaller overall diameter control cable.\u003cbr\u003e The properties of Okonite-FMR insulation substantially enhance the well known features of ethylene propylene rubber insulations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield\u003c\/strong\u003e\u003cbr\u003e The shield system consists of a 5 mil copper tape which is longitudinally applied over the extruded belt and fill. The Longitudinal Corrugated Shield (LCS) maintains uniformly low resistance and a low reactance path for optimum shielding against external high frequency interference.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket\u003c\/strong\u003e\u003cbr\u003e The Okolon TS-CPE jacket is a thermoset chlorinated polyethylene compound. This combination construction assures circuit security because of its high mechanical strength and excellent resistance to moisture, ozone, oil and most chemicals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003cbr\u003e Okonite-FMR Control Cables are recommended for use in either power generating plants and in substations; designed especially for critical circuits where continuity of service is of prime importance. This premium quality control cable is recommended for wet or dry, ac or dc service at conductor temperatures to 90°C. They may be installed in conduits, ducts, cable troughs, trays, messenger supported, or directly buried in the earth.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductors:\u003c\/strong\u003e Coated copper per ASTM B-33, Class B stranded per ASTM B-8.\u003cbr\u003e \u003cstrong\u003eInsulation: \u003c\/strong\u003eOkonite-FMR meets or exceeds the electrical and physical requirements of ICEA S-73-532.\u003cbr\u003e \u003cstrong\u003eColor Coding: \u003c\/strong\u003eBase colors and tracers per ICEA Method 1 Table E-1. Sequence shown on reverse of this sheet.\u003cbr\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled using flame and moisture resistant fillers.\u003cbr\u003e \u003cstrong\u003eShield: \u003c\/strong\u003eA 5 mil corrugated copper tape, longitudinally applied.\u003cbr\u003e \u003cstrong\u003eOverall Jacket: \u003c\/strong\u003eThe Okolon TS-CPE compound meets or ex- ceeds the requirements of ICEA S-73-532\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFlame retardant - passes the IEEE 383 and 1202 flame test requirements. Also passes the ICEA T-29-520 (210,000 BTU\/hr) flame test.\u003c\/li\u003e\n\u003cli\u003eQuality Assurance traceability available on special order.\u003c\/li\u003e\n\u003cli\u003e90°C rated control cable, factory assembled for indoor or outdoor installation in cable trays, in raceways, direct burial in the earth, or supported by messenger wire.\u003c\/li\u003e\n\u003cli\u003eMechanically rugged.\u003c\/li\u003e\n\u003cli\u003eFlexible, easy to install and terminate.\u003c\/li\u003e\n\u003cli\u003eColor coded conductors.\u003c\/li\u003e\n\u003cli\u003eResistant to water, oil and most chemicals.\u003c\/li\u003e\n\u003cli\u003eThermally stable at elevated temperatures.\u003c\/li\u003e\n\u003cli\u003eHigh insulation resistance, even at elevated temperatures.\u003c\/li\u003e\n\u003cli\u003eSmall diameter, lightweight.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27552879444068,"sku":"NNC8235X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/okonite-fmr-lcs_41_0fa5895b-6346-4506-981c-f6c1b3a56826.jpg?v=1759805477"},{"product_id":"202-14-6057-okonite-fmr-lcs-okolon-ts-cpe-1000v-16-awg-7-conductors","title":"202-14-6057 Okonite-FMR-LCS Okolon TS-CPE - 1000V - 16 AWG - 7 Conductors","description":"\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003cbr\u003e Okonite-FMR is Okonite’s trade name for its heat, moisture, flame and chemically resistant, mechanically rugged ethylene-propylene insulation compound. It is flame retardant and will pass both the 70,000 BTU\/hour and 210,000 BTU\/hour tray flame test. Its physical properties and flame retardency permit its use without a jacket on the single conductors thus providing a substantially smaller overall diameter control cable.\u003cbr\u003e The properties of Okonite-FMR insulation substantially enhance the well known features of ethylene propylene rubber insulations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield\u003c\/strong\u003e\u003cbr\u003e The shield system consists of a 5 mil copper tape which is longitudinally applied over the extruded belt and fill. The Longitudinal Corrugated Shield (LCS) maintains uniformly low resistance and a low reactance path for optimum shielding against external high frequency interference.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket\u003c\/strong\u003e\u003cbr\u003e The Okolon TS-CPE jacket is a thermoset chlorinated polyethylene compound. This combination construction assures circuit security because of its high mechanical strength and excellent resistance to moisture, ozone, oil and most chemicals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003cbr\u003e Okonite-FMR Control Cables are recommended for use in either power generating plants and in substations; designed especially for critical circuits where continuity of service is of prime importance. This premium quality control cable is recommended for wet or dry, ac or dc service at conductor temperatures to 90°C. They may be installed in conduits, ducts, cable troughs, trays, messenger supported, or directly buried in the earth.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductors:\u003c\/strong\u003e Coated copper per ASTM B-33, Class B stranded per ASTM B-8.\u003cbr\u003e \u003cstrong\u003eInsulation: \u003c\/strong\u003eOkonite-FMR meets or exceeds the electrical and physical requirements of ICEA S-73-532.\u003cbr\u003e \u003cstrong\u003eColor Coding: \u003c\/strong\u003eBase colors and tracers per ICEA Method 1 Table E-1. Sequence shown on reverse of this sheet.\u003cbr\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled using flame and moisture resistant fillers.\u003cbr\u003e \u003cstrong\u003eShield: \u003c\/strong\u003eA 5 mil corrugated copper tape, longitudinally applied.\u003cbr\u003e \u003cstrong\u003eOverall Jacket: \u003c\/strong\u003eThe Okolon TS-CPE compound meets or ex- ceeds the requirements of ICEA S-73-532\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFlame retardant - passes the IEEE 383 and 1202 flame test requirements. Also passes the ICEA T-29-520 (210,000 BTU\/hr) flame test.\u003c\/li\u003e\n\u003cli\u003eQuality Assurance traceability available on special order.\u003c\/li\u003e\n\u003cli\u003e90°C rated control cable, factory assembled for indoor or outdoor installation in cable trays, in raceways, direct burial in the earth, or supported by messenger wire.\u003c\/li\u003e\n\u003cli\u003eMechanically rugged.\u003c\/li\u003e\n\u003cli\u003eFlexible, easy to install and terminate.\u003c\/li\u003e\n\u003cli\u003eColor coded conductors.\u003c\/li\u003e\n\u003cli\u003eResistant to water, oil and most chemicals.\u003c\/li\u003e\n\u003cli\u003eThermally stable at elevated temperatures.\u003c\/li\u003e\n\u003cli\u003eHigh insulation resistance, even at elevated temperatures.\u003c\/li\u003e\n\u003cli\u003eSmall diameter, lightweight.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27552879509604,"sku":"NNC8236X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/okonite-fmr-lcs_41_29cc667d-cab8-42da-9eda-26f646d38582.jpg?v=1762461747"},{"product_id":"202-14-6059-okonite-fmr-lcs-okolon-ts-cpe-1000v-16-awg-9-conductors","title":"202-14-6059 Okonite-FMR-LCS Okolon TS-CPE - 1000V - 16 AWG - 9 Conductors","description":"\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003cbr\u003e Okonite-FMR is Okonite’s trade name for its heat, moisture, flame and chemically resistant, mechanically rugged ethylene-propylene insulation compound. It is flame retardant and will pass both the 70,000 BTU\/hour and 210,000 BTU\/hour tray flame test. Its physical properties and flame retardency permit its use without a jacket on the single conductors thus providing a substantially smaller overall diameter control cable.\u003cbr\u003e The properties of Okonite-FMR insulation substantially enhance the well known features of ethylene propylene rubber insulations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield\u003c\/strong\u003e\u003cbr\u003e The shield system consists of a 5 mil copper tape which is longitudinally applied over the extruded belt and fill. The Longitudinal Corrugated Shield (LCS) maintains uniformly low resistance and a low reactance path for optimum shielding against external high frequency interference.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket\u003c\/strong\u003e\u003cbr\u003e The Okolon TS-CPE jacket is a thermoset chlorinated polyethylene compound. This combination construction assures circuit security because of its high mechanical strength and excellent resistance to moisture, ozone, oil and most chemicals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003cbr\u003e Okonite-FMR Control Cables are recommended for use in either power generating plants and in substations; designed especially for critical circuits where continuity of service is of prime importance. This premium quality control cable is recommended for wet or dry, ac or dc service at conductor temperatures to 90°C. They may be installed in conduits, ducts, cable troughs, trays, messenger supported, or directly buried in the earth.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductors:\u003c\/strong\u003e Coated copper per ASTM B-33, Class B stranded per ASTM B-8.\u003cbr\u003e \u003cstrong\u003eInsulation: \u003c\/strong\u003eOkonite-FMR meets or exceeds the electrical and physical requirements of ICEA S-73-532.\u003cbr\u003e \u003cstrong\u003eColor Coding: \u003c\/strong\u003eBase colors and tracers per ICEA Method 1 Table E-1. Sequence shown on reverse of this sheet.\u003cbr\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled using flame and moisture resistant fillers.\u003cbr\u003e \u003cstrong\u003eShield: \u003c\/strong\u003eA 5 mil corrugated copper tape, longitudinally applied.\u003cbr\u003e \u003cstrong\u003eOverall Jacket: \u003c\/strong\u003eThe Okolon TS-CPE compound meets or ex- ceeds the requirements of ICEA S-73-532\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFlame retardant - passes the IEEE 383 and 1202 flame test requirements. Also passes the ICEA T-29-520 (210,000 BTU\/hr) flame test.\u003c\/li\u003e\n\u003cli\u003eQuality Assurance traceability available on special order.\u003c\/li\u003e\n\u003cli\u003e90°C rated control cable, factory assembled for indoor or outdoor installation in cable trays, in raceways, direct burial in the earth, or supported by messenger wire.\u003c\/li\u003e\n\u003cli\u003eMechanically rugged.\u003c\/li\u003e\n\u003cli\u003eFlexible, easy to install and terminate.\u003c\/li\u003e\n\u003cli\u003eColor coded conductors.\u003c\/li\u003e\n\u003cli\u003eResistant to water, oil and most chemicals.\u003c\/li\u003e\n\u003cli\u003eThermally stable at elevated temperatures.\u003c\/li\u003e\n\u003cli\u003eHigh insulation resistance, even at elevated temperatures.\u003c\/li\u003e\n\u003cli\u003eSmall diameter, lightweight.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27552879575140,"sku":"NNC8237X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/okonite-fmr-lcs_41_cc6fc568-f381-4503-a3d0-1cba018f8848.jpg?v=1759805478"},{"product_id":"202-14-6062-okonite-fmr-lcs-okolon-ts-cpe-1000v-16-awg-12-conductors","title":"202-14-6062 Okonite-FMR-LCS Okolon TS-CPE - 1000V - 16 AWG - 12 Conductors","description":"\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003cbr\u003e Okonite-FMR is Okonite’s trade name for its heat, moisture, flame and chemically resistant, mechanically rugged ethylene-propylene insulation compound. It is flame retardant and will pass both the 70,000 BTU\/hour and 210,000 BTU\/hour tray flame test. Its physical properties and flame retardency permit its use without a jacket on the single conductors thus providing a substantially smaller overall diameter control cable.\u003cbr\u003e The properties of Okonite-FMR insulation substantially enhance the well known features of ethylene propylene rubber insulations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield\u003c\/strong\u003e\u003cbr\u003e The shield system consists of a 5 mil copper tape which is longitudinally applied over the extruded belt and fill. The Longitudinal Corrugated Shield (LCS) maintains uniformly low resistance and a low reactance path for optimum shielding against external high frequency interference.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket\u003c\/strong\u003e\u003cbr\u003e The Okolon TS-CPE jacket is a thermoset chlorinated polyethylene compound. This combination construction assures circuit security because of its high mechanical strength and excellent resistance to moisture, ozone, oil and most chemicals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003cbr\u003e Okonite-FMR Control Cables are recommended for use in either power generating plants and in substations; designed especially for critical circuits where continuity of service is of prime importance. This premium quality control cable is recommended for wet or dry, ac or dc service at conductor temperatures to 90°C. They may be installed in conduits, ducts, cable troughs, trays, messenger supported, or directly buried in the earth.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductors:\u003c\/strong\u003e Coated copper per ASTM B-33, Class B stranded per ASTM B-8.\u003cbr\u003e \u003cstrong\u003eInsulation: \u003c\/strong\u003eOkonite-FMR meets or exceeds the electrical and physical requirements of ICEA S-73-532.\u003cbr\u003e \u003cstrong\u003eColor Coding: \u003c\/strong\u003eBase colors and tracers per ICEA Method 1 Table E-1. Sequence shown on reverse of this sheet.\u003cbr\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled using flame and moisture resistant fillers.\u003cbr\u003e \u003cstrong\u003eShield: \u003c\/strong\u003eA 5 mil corrugated copper tape, longitudinally applied.\u003cbr\u003e \u003cstrong\u003eOverall Jacket: \u003c\/strong\u003eThe Okolon TS-CPE compound meets or ex- ceeds the requirements of ICEA S-73-532\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFlame retardant - passes the IEEE 383 and 1202 flame test requirements. Also passes the ICEA T-29-520 (210,000 BTU\/hr) flame test.\u003c\/li\u003e\n\u003cli\u003eQuality Assurance traceability available on special order.\u003c\/li\u003e\n\u003cli\u003e90°C rated control cable, factory assembled for indoor or outdoor installation in cable trays, in raceways, direct burial in the earth, or supported by messenger wire.\u003c\/li\u003e\n\u003cli\u003eMechanically rugged.\u003c\/li\u003e\n\u003cli\u003eFlexible, easy to install and terminate.\u003c\/li\u003e\n\u003cli\u003eColor coded conductors.\u003c\/li\u003e\n\u003cli\u003eResistant to water, oil and most chemicals.\u003c\/li\u003e\n\u003cli\u003eThermally stable at elevated temperatures.\u003c\/li\u003e\n\u003cli\u003eHigh insulation resistance, even at elevated temperatures.\u003c\/li\u003e\n\u003cli\u003eSmall diameter, lightweight.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27552879607908,"sku":"NNC8238X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/okonite-fmr-lcs_41_e6dda05c-d939-4e93-99ec-1d8ec4f8ff50.jpg?v=1759805478"},{"product_id":"202-14-6069-okonite-fmr-lcs-okolon-ts-cpe-1000v-16-awg-19-conductors","title":"202-14-6069 Okonite-FMR-LCS Okolon TS-CPE - 1000V - 16 AWG - 19 Conductors","description":"\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003cbr\u003e Okonite-FMR is Okonite’s trade name for its heat, moisture, flame and chemically resistant, mechanically rugged ethylene-propylene insulation compound. It is flame retardant and will pass both the 70,000 BTU\/hour and 210,000 BTU\/hour tray flame test. Its physical properties and flame retardency permit its use without a jacket on the single conductors thus providing a substantially smaller overall diameter control cable.\u003cbr\u003e The properties of Okonite-FMR insulation substantially enhance the well known features of ethylene propylene rubber insulations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield\u003c\/strong\u003e\u003cbr\u003e The shield system consists of a 5 mil copper tape which is longitudinally applied over the extruded belt and fill. The Longitudinal Corrugated Shield (LCS) maintains uniformly low resistance and a low reactance path for optimum shielding against external high frequency interference.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket\u003c\/strong\u003e\u003cbr\u003e The Okolon TS-CPE jacket is a thermoset chlorinated polyethylene compound. This combination construction assures circuit security because of its high mechanical strength and excellent resistance to moisture, ozone, oil and most chemicals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003cbr\u003e Okonite-FMR Control Cables are recommended for use in either power generating plants and in substations; designed especially for critical circuits where continuity of service is of prime importance. This premium quality control cable is recommended for wet or dry, ac or dc service at conductor temperatures to 90°C. They may be installed in conduits, ducts, cable troughs, trays, messenger supported, or directly buried in the earth.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductors:\u003c\/strong\u003e Coated copper per ASTM B-33, Class B stranded per ASTM B-8.\u003cbr\u003e \u003cstrong\u003eInsulation: \u003c\/strong\u003eOkonite-FMR meets or exceeds the electrical and physical requirements of ICEA S-73-532.\u003cbr\u003e \u003cstrong\u003eColor Coding: \u003c\/strong\u003eBase colors and tracers per ICEA Method 1 Table E-1. Sequence shown on reverse of this sheet.\u003cbr\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled using flame and moisture resistant fillers.\u003cbr\u003e \u003cstrong\u003eShield: \u003c\/strong\u003eA 5 mil corrugated copper tape, longitudinally applied.\u003cbr\u003e \u003cstrong\u003eOverall Jacket: \u003c\/strong\u003eThe Okolon TS-CPE compound meets or ex- ceeds the requirements of ICEA S-73-532\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFlame retardant - passes the IEEE 383 and 1202 flame test requirements. Also passes the ICEA T-29-520 (210,000 BTU\/hr) flame test.\u003c\/li\u003e\n\u003cli\u003eQuality Assurance traceability available on special order.\u003c\/li\u003e\n\u003cli\u003e90°C rated control cable, factory assembled for indoor or outdoor installation in cable trays, in raceways, direct burial in the earth, or supported by messenger wire.\u003c\/li\u003e\n\u003cli\u003eMechanically rugged.\u003c\/li\u003e\n\u003cli\u003eFlexible, easy to install and terminate.\u003c\/li\u003e\n\u003cli\u003eColor coded conductors.\u003c\/li\u003e\n\u003cli\u003eResistant to water, oil and most chemicals.\u003c\/li\u003e\n\u003cli\u003eThermally stable at elevated temperatures.\u003c\/li\u003e\n\u003cli\u003eHigh insulation resistance, even at elevated temperatures.\u003c\/li\u003e\n\u003cli\u003eSmall diameter, lightweight.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27552879837284,"sku":"NNC8239X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/okonite-fmr-lcs_41_e5974da0-d67d-4a7c-b99a-93a65ab22361.jpg?v=1762461750"},{"product_id":"202-14-6087-okonite-fmr-lcs-okolon-ts-cpe-1000v-16-awg-37-conductors","title":"202-14-6087 Okonite-FMR-LCS Okolon TS-CPE - 1000V - 16 AWG - 37 Conductors","description":"\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003cbr\u003e Okonite-FMR is Okonite’s trade name for its heat, moisture, flame and chemically resistant, mechanically rugged ethylene-propylene insulation compound. It is flame retardant and will pass both the 70,000 BTU\/hour and 210,000 BTU\/hour tray flame test. Its physical properties and flame retardency permit its use without a jacket on the single conductors thus providing a substantially smaller overall diameter control cable.\u003cbr\u003e The properties of Okonite-FMR insulation substantially enhance the well known features of ethylene propylene rubber insulations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield\u003c\/strong\u003e\u003cbr\u003e The shield system consists of a 5 mil copper tape which is longitudinally applied over the extruded belt and fill. The Longitudinal Corrugated Shield (LCS) maintains uniformly low resistance and a low reactance path for optimum shielding against external high frequency interference.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket\u003c\/strong\u003e\u003cbr\u003e The Okolon TS-CPE jacket is a thermoset chlorinated polyethylene compound. This combination construction assures circuit security because of its high mechanical strength and excellent resistance to moisture, ozone, oil and most chemicals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003cbr\u003e Okonite-FMR Control Cables are recommended for use in either power generating plants and in substations; designed especially for critical circuits where continuity of service is of prime importance. This premium quality control cable is recommended for wet or dry, ac or dc service at conductor temperatures to 90°C. They may be installed in conduits, ducts, cable troughs, trays, messenger supported, or directly buried in the earth.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductors:\u003c\/strong\u003e Coated copper per ASTM B-33, Class B stranded per ASTM B-8.\u003cbr\u003e \u003cstrong\u003eInsulation: \u003c\/strong\u003eOkonite-FMR meets or exceeds the electrical and physical requirements of ICEA S-73-532.\u003cbr\u003e \u003cstrong\u003eColor Coding: \u003c\/strong\u003eBase colors and tracers per ICEA Method 1 Table E-1. Sequence shown on reverse of this sheet.\u003cbr\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled using flame and moisture resistant fillers.\u003cbr\u003e \u003cstrong\u003eShield: \u003c\/strong\u003eA 5 mil corrugated copper tape, longitudinally applied.\u003cbr\u003e \u003cstrong\u003eOverall Jacket: \u003c\/strong\u003eThe Okolon TS-CPE compound meets or ex- ceeds the requirements of ICEA S-73-532\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFlame retardant - passes the IEEE 383 and 1202 flame test requirements. Also passes the ICEA T-29-520 (210,000 BTU\/hr) flame test.\u003c\/li\u003e\n\u003cli\u003eQuality Assurance traceability available on special order.\u003c\/li\u003e\n\u003cli\u003e90°C rated control cable, factory assembled for indoor or outdoor installation in cable trays, in raceways, direct burial in the earth, or supported by messenger wire.\u003c\/li\u003e\n\u003cli\u003eMechanically rugged.\u003c\/li\u003e\n\u003cli\u003eFlexible, easy to install and terminate.\u003c\/li\u003e\n\u003cli\u003eColor coded conductors.\u003c\/li\u003e\n\u003cli\u003eResistant to water, oil and most chemicals.\u003c\/li\u003e\n\u003cli\u003eThermally stable at elevated temperatures.\u003c\/li\u003e\n\u003cli\u003eHigh insulation resistance, even at elevated temperatures.\u003c\/li\u003e\n\u003cli\u003eSmall diameter, lightweight.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27552880754788,"sku":"NNC8240X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/okonite-fmr-lcs_41_e300af0a-84d1-4433-8e89-248def620210.jpg?v=1762461750"},{"product_id":"okonite-fmr-lcs-okolon-ts-cpe-1000v","title":"Okonite-FMR-LCS Okolon TS-CPE - 1000V","description":"[short]\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003cbr\u003e\nOkonite-FMR Control Cables are recommended for use in either power generating plants and in substations; designed especially for critical circuits where continuity of service is of prime importance. This premium quality control cable is recommended for wet or dry, ac or dc service at conductor temperatures to 90°C. They may be installed in conduits, ducts, cable troughs, trays, messenger supported, or directly buried in the earth.\u003c\/p\u003e\n[\/short]\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003cbr\u003e Okonite-FMR is Okonite’s trade name for its heat, moisture, flame and chemically resistant, mechanically rugged ethylene-propylene insulation compound. It is flame retardant and will pass both the 70,000 BTU\/hour and 210,000 BTU\/hour tray flame test. Its physical properties and flame retardency permit its use without a jacket on the single conductors thus providing a substantially smaller overall diameter control cable.\u003cbr\u003e The properties of Okonite-FMR insulation substantially enhance the well known features of ethylene propylene rubber insulations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield\u003c\/strong\u003e\u003cbr\u003e The shield system consists of a 5 mil copper tape which is longitudinally applied over the extruded belt and fill. The Longitudinal Corrugated Shield (LCS) maintains uniformly low resistance and a low reactance path for optimum shielding against external high frequency interference.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket\u003c\/strong\u003e\u003cbr\u003e The Okolon TS-CPE jacket is a thermoset chlorinated polyethylene compound. This combination construction assures circuit security because of its high mechanical strength and excellent resistance to moisture, ozone, oil and most chemicals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductors:\u003c\/strong\u003e Coated copper per ASTM B-33, Class B stranded per ASTM B-8.\u003cbr\u003e \u003cstrong\u003eInsulation: \u003c\/strong\u003eOkonite-FMR meets or exceeds the electrical and physical requirements of ICEA S-73-532.\u003cbr\u003e \u003cstrong\u003eColor Coding: \u003c\/strong\u003eBase colors and tracers per ICEA Method 1 Table E-1. Sequence shown on reverse of this sheet.\u003cbr\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled using flame and moisture resistant fillers.\u003cbr\u003e \u003cstrong\u003eShield: \u003c\/strong\u003eA 5 mil corrugated copper tape, longitudinally applied.\u003cbr\u003e \u003cstrong\u003eOverall Jacket: \u003c\/strong\u003eThe Okolon TS-CPE compound meets or ex- ceeds the requirements of ICEA S-73-532\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFlame retardant - passes the IEEE 383 and 1202 flame test requirements. Also passes the ICEA T-29-520 (210,000 BTU\/hr) flame test.\u003c\/li\u003e\n\u003cli\u003eQuality Assurance traceability available on special order.\u003c\/li\u003e\n\u003cli\u003e90°C rated control cable, factory assembled for indoor or outdoor installation in cable trays, in raceways, direct burial in the earth, or supported by messenger wire.\u003c\/li\u003e\n\u003cli\u003eMechanically rugged.\u003c\/li\u003e\n\u003cli\u003eFlexible, easy to install and terminate.\u003c\/li\u003e\n\u003cli\u003eColor coded conductors.\u003c\/li\u003e\n\u003cli\u003eResistant to water, oil and most chemicals.\u003c\/li\u003e\n\u003cli\u003eThermally stable at elevated temperatures.\u003c\/li\u003e\n\u003cli\u003eHigh insulation resistance, even at elevated temperatures.\u003c\/li\u003e\n\u003cli\u003eSmall diameter, lightweight.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27552881508452,"sku":"NNC8241X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/okonite-fmr-lcs_41_1ec97e67-fc19-407f-bd06-a5f16406b711.jpg?v=1762461751"},{"product_id":"203-84-3301-p-45-1000v-control-cable-12-awg-twin-conductors","title":"203-84-3301 P-45 1000V Control Cable - 12 AWG - Twin Conductors","description":"\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003cbr\u003e Okolene® is Okonite’s trade name for its natural polyethylene insulation with outstanding dielectric strength. The insulation thickness is 30 mils.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJackets and Finishes\u003c\/strong\u003e\u003cbr\u003e The 15 mil Okoseal® (PVC) jacket over the individual conductors provides additional mechanical strength. The color coding used in these cables is in accordance with ICEA Standard S-73-532, Table E-1. The six, standard, solid-base colors, in order are: black, white, red, green, orange and blue, followed by permanent tracer colors, black, white, red, and green, to code a total of 21 conductors. The Okoseal (PVC) outer jacket supplied with these cables has excellent resistance to oil and most chemicals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003cbr\u003e P-45 control cables are recommended as economical, high quality, general purpose low voltage control cables, for use in wet or dry locations, ac or dc service, in conduit, duct, troughs, or direct burial installations\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductors:\u003c\/strong\u003e Class “B” stranded bare copper, per ASTM B-8 (except #9 AWG which is Class “C” stranding).\u003cbr\u003e \u003cstrong\u003eInsulation: \u003c\/strong\u003e Okolene (polyethylene) meets or exceeds applicable requirements of ICEA S-73-532.\u003cbr\u003e \u003cstrong\u003eJacket: \u003c\/strong\u003eMeet or exceed applicable requirements of ICEA S-73-532.\u003cbr\u003e Assembled with fillers where necessary, non-hygroscopic tape and Okoseal jacket overall.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eColor coded for permanent identification.\u003c\/li\u003e\n\u003cli\u003eRated 75°C continuous operating temperature.\u003c\/li\u003e\n\u003cli\u003eSmall diameter, light weight.\u003c\/li\u003e\n\u003cli\u003eMechanically tough.\u003c\/li\u003e\n\u003cli\u003eExcellent moisture and heat resistance.\u003c\/li\u003e\n\u003cli\u003eFlexible, easy to handle.\u003c\/li\u003e\n\u003cli\u003eOutstanding resistance to most oils, acids and alkalies.\u003c\/li\u003e\n\u003cli\u003eHigh dielectric strength.\u003c\/li\u003e\n\u003cli\u003eExcellent electrical properties in wet or dry locations, ac or dc.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27552895238244,"sku":"NNC8273X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/p-30-600v-control-cable_42_4313838d-64a4-4d04-bf9c-eda213b82bae.jpg?v=1762461773"},{"product_id":"203-84-3303-p-45-1000v-control-cable-12-awg-3-conductors","title":"203-84-3303 P-45 1000V Control Cable - 12 AWG - 3 Conductors","description":"\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003cbr\u003e Okolene® is Okonite’s trade name for its natural polyethylene insulation with outstanding dielectric strength. The insulation thickness is 30 mils.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJackets and Finishes\u003c\/strong\u003e\u003cbr\u003e The 15 mil Okoseal® (PVC) jacket over the individual conductors provides additional mechanical strength. The color coding used in these cables is in accordance with ICEA Standard S-73-532, Table E-1. The six, standard, solid-base colors, in order are: black, white, red, green, orange and blue, followed by permanent tracer colors, black, white, red, and green, to code a total of 21 conductors. The Okoseal (PVC) outer jacket supplied with these cables has excellent resistance to oil and most chemicals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003cbr\u003e P-45 control cables are recommended as economical, high quality, general purpose low voltage control cables, for use in wet or dry locations, ac or dc service, in conduit, duct, troughs, or direct burial installations\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductors:\u003c\/strong\u003e Class “B” stranded bare copper, per ASTM B-8 (except #9 AWG which is Class “C” stranding).\u003cbr\u003e \u003cstrong\u003eInsulation: \u003c\/strong\u003e Okolene (polyethylene) meets or exceeds applicable requirements of ICEA S-73-532.\u003cbr\u003e \u003cstrong\u003eJacket: \u003c\/strong\u003eMeet or exceed applicable requirements of ICEA S-73-532.\u003cbr\u003e Assembled with fillers where necessary, non-hygroscopic tape and Okoseal jacket overall.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eColor coded for permanent identification.\u003c\/li\u003e\n\u003cli\u003eRated 75°C continuous operating temperature.\u003c\/li\u003e\n\u003cli\u003eSmall diameter, light weight.\u003c\/li\u003e\n\u003cli\u003eMechanically tough.\u003c\/li\u003e\n\u003cli\u003eExcellent moisture and heat resistance.\u003c\/li\u003e\n\u003cli\u003eFlexible, easy to handle.\u003c\/li\u003e\n\u003cli\u003eOutstanding resistance to most oils, acids and alkalies.\u003c\/li\u003e\n\u003cli\u003eHigh dielectric strength.\u003c\/li\u003e\n\u003cli\u003eExcellent electrical properties in wet or dry locations, ac or dc.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27552895533156,"sku":"NNC8274X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/p-30-600v-control-cable_42_0f6e1b86-e6e9-4139-9022-723d6bf82528.jpg?v=1762461773"},{"product_id":"203-84-3304-p-45-1000v-control-cable-12-awg-4-conductors","title":"203-84-3304 P-45 1000V Control Cable - 12 AWG - 4 Conductors","description":"\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003cbr\u003e Okolene® is Okonite’s trade name for its natural polyethylene insulation with outstanding dielectric strength. The insulation thickness is 30 mils.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJackets and Finishes\u003c\/strong\u003e\u003cbr\u003e The 15 mil Okoseal® (PVC) jacket over the individual conductors provides additional mechanical strength. The color coding used in these cables is in accordance with ICEA Standard S-73-532, Table E-1. The six, standard, solid-base colors, in order are: black, white, red, green, orange and blue, followed by permanent tracer colors, black, white, red, and green, to code a total of 21 conductors. The Okoseal (PVC) outer jacket supplied with these cables has excellent resistance to oil and most chemicals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003cbr\u003e P-45 control cables are recommended as economical, high quality, general purpose low voltage control cables, for use in wet or dry locations, ac or dc service, in conduit, duct, troughs, or direct burial installations\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductors:\u003c\/strong\u003e Class “B” stranded bare copper, per ASTM B-8 (except #9 AWG which is Class “C” stranding).\u003cbr\u003e \u003cstrong\u003eInsulation: \u003c\/strong\u003e Okolene (polyethylene) meets or exceeds applicable requirements of ICEA S-73-532.\u003cbr\u003e \u003cstrong\u003eJacket: \u003c\/strong\u003eMeet or exceed applicable requirements of ICEA S-73-532.\u003cbr\u003e Assembled with fillers where necessary, non-hygroscopic tape and Okoseal jacket overall.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eColor coded for permanent identification.\u003c\/li\u003e\n\u003cli\u003eRated 75°C continuous operating temperature.\u003c\/li\u003e\n\u003cli\u003eSmall diameter, light weight.\u003c\/li\u003e\n\u003cli\u003eMechanically tough.\u003c\/li\u003e\n\u003cli\u003eExcellent moisture and heat resistance.\u003c\/li\u003e\n\u003cli\u003eFlexible, easy to handle.\u003c\/li\u003e\n\u003cli\u003eOutstanding resistance to most oils, acids and alkalies.\u003c\/li\u003e\n\u003cli\u003eHigh dielectric strength.\u003c\/li\u003e\n\u003cli\u003eExcellent electrical properties in wet or dry locations, ac or dc.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27552897106020,"sku":"NNC8275X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/p-30-600v-control-cable_42_2ecbad4e-d131-45c6-af72-8760ec910b91.jpg?v=1762461774"},{"product_id":"203-84-3305-p-45-1000v-control-cable-12-awg-5conductors","title":"203-84-3305 P-45 1000V Control Cable - 12 AWG - 5Conductors","description":"\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003cbr\u003e Okolene® is Okonite’s trade name for its natural polyethylene insulation with outstanding dielectric strength. The insulation thickness is 30 mils.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJackets and Finishes\u003c\/strong\u003e\u003cbr\u003e The 15 mil Okoseal® (PVC) jacket over the individual conductors provides additional mechanical strength. The color coding used in these cables is in accordance with ICEA Standard S-73-532, Table E-1. The six, standard, solid-base colors, in order are: black, white, red, green, orange and blue, followed by permanent tracer colors, black, white, red, and green, to code a total of 21 conductors. The Okoseal (PVC) outer jacket supplied with these cables has excellent resistance to oil and most chemicals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003cbr\u003e P-45 control cables are recommended as economical, high quality, general purpose low voltage control cables, for use in wet or dry locations, ac or dc service, in conduit, duct, troughs, or direct burial installations\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductors:\u003c\/strong\u003e Class “B” stranded bare copper, per ASTM B-8 (except #9 AWG which is Class “C” stranding).\u003cbr\u003e \u003cstrong\u003eInsulation: \u003c\/strong\u003e Okolene (polyethylene) meets or exceeds applicable requirements of ICEA S-73-532.\u003cbr\u003e \u003cstrong\u003eJacket: \u003c\/strong\u003eMeet or exceed applicable requirements of ICEA S-73-532.\u003cbr\u003e Assembled with fillers where necessary, non-hygroscopic tape and Okoseal jacket overall.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eColor coded for permanent identification.\u003c\/li\u003e\n\u003cli\u003eRated 75°C continuous operating temperature.\u003c\/li\u003e\n\u003cli\u003eSmall diameter, light weight.\u003c\/li\u003e\n\u003cli\u003eMechanically tough.\u003c\/li\u003e\n\u003cli\u003eExcellent moisture and heat resistance.\u003c\/li\u003e\n\u003cli\u003eFlexible, easy to handle.\u003c\/li\u003e\n\u003cli\u003eOutstanding resistance to most oils, acids and alkalies.\u003c\/li\u003e\n\u003cli\u003eHigh dielectric strength.\u003c\/li\u003e\n\u003cli\u003eExcellent electrical properties in wet or dry locations, ac or dc.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27552898187364,"sku":"NNC8276X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/p-30-600v-control-cable_42_cc933ad3-a73b-4edd-a679-80995ae1f0f8.jpg?v=1759805484"}],"url":"https:\/\/nassaunationalcable.com\/en-ca\/collections\/1000-volts-wire-and-cables.oembed?page=35","provider":"NassauNationalCable","version":"1.0","type":"link"}