{"title":"VFD CABLE","description":"","products":[{"product_id":"series-v-flex-flexible-vfd","title":"Series V-Flex Flexible VFD","description":"\u003cp\u003e\u003cstrong\u003eSeries V-Flex Features:\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cul\u003e\r\n \u003cli\u003eRated for use at temperatures as low as -40°C  \u003c\/li\u003e\r\n \u003cli\u003eUL and CSA Tray Cable approved \u003c\/li\u003e\r\n \u003cli\u003eSunlight resistance and excellent resistance to solvents and oils\u003c\/li\u003e\r\n \u003cli\u003eTPE jacket\u003c\/li\u003e\r\n \u003cli\u003e5x Static Bend Radius \u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e\u003cstrong\u003eSeries V-Flex Benefits:\u003c\/strong\u003e \u003c\/p\u003e\r\n\u003cul\u003e\r\n \u003cli\u003eSuperior flexibility for easier routing and easier handling \u003c\/li\u003e\r\n \u003cli\u003eReduced chance of cable failure from voltage irregularites such as harmonics, corona discharges, and power distortion\u003c\/li\u003e\r\n \u003cli\u003eLow capacitance for improved signal transmission \u003c\/li\u003e\r\n \u003cli\u003eDouble shielded for maximum EMI protection \u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27578768031844,"sku":"NNC13088X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/series-v-flex-flexible-vfd_7_53bed846-7566-4378-9b4c-5a49ef857d81.jpg?v=1759806506"},{"product_id":"vfd-armored-sheathed-w-ground-2kv-shipboard-cable","title":"VFD Armored Sheathed W\/ Ground 2KV Shipboard Cable","description":"\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDesigned and constructed for the demanding environments of offshore drilling and petroleum facilities located throughout the world.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eFlame Retardant Cross-linked Polyolefin, meeting the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. COLOR C\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eBlack, arctic grade, flame retardant, oil, abrasion, chemical and sunlight resistant thermosetting compound meeting UL 1309\/CSA C22.2 No. 245 and IEEE 1580.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDark gray with printed phase I.D. (Black-White-Red)\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eShield:\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eTinned copper basket weave wire armor per IEEE 1580 and UL 1309\/CSA 245 plus aluminum\/polyester tape providing 100% coverage.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGrounding\u003c\/strong\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003e3 soft annealed, flexible stranded, with green Gexol® insulated tinned copper conductors\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27781718081636,"sku":"NNC32248X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/vfd_armored_2_7b32de86-593e-4978-9984-9aa95b3719d6.jpg?v=1762477481"},{"product_id":"vfd-thin-bare-copper-ul-csa-tc-er-ce-pvc-shielded-vfd-cable","title":"VFD-THIN Bare Copper UL\/CSA\/TC-ER\/CE PVC Shielded VFD Cable","description":"\u003cstyle type=\"text\/css\" data-mce-fragment=\"1\"\u003e\u003c!--\ntd {border: 1px solid #ccc;}br {mso-data-placement:same-cell;}\n--\u003e\u003c\/style\u003e\n\u003cp\u003e\u003cstrong\u003eVFD-THIN Bare Copper UL\/CSA\/TC-ER\/CE PVC Shielded VFD Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003eAlso Known as:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eMueller Cable, Motor Supply Cable, Bare Copper Cable, Flexible Cable, Ground Wire \u003cspan data-mce-fragment=\"1\"\u003eCable\u003c\/span\u003e, VFD-THIN Cable\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eDescription:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eVFD-THIN is a flexible, UL\/CSA\/CE approved, PVC\/Nylon insulated, PVC jacketed, shielded tray cable rated, motor supply cable designed for automated systems. The 100% coverage foil and tinned copper braid shield helps with problems due to voltage spikes, harmonics, electrical interference and power distortions commonly associated with variable frequency drives. VFD-THIN can be used to connect alternating current variable frequency drives to alternating current variable drive motors and is TC-ER (tray cable) approved for open wiring (exposed run). This motor supply cable is also suitable for installations in wet or dry environments and is UV resistant. Can also be used indoor or outdoor and is rated for direct burial.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e• Fine bare copper strands \u003cbr\u003e• Strands to American class-K as listed below \u003cbr\u003e• Special PVC\/nylon core insulation \u003cbr\u003e• Color code VDE-0293 - black \u0026amp; numbered \u003cbr\u003e• Ground wire in outer layer \u003cbr\u003e• Fleece wrapping over cores \u003cbr\u003e• 100% foil and 90% tinned copper braid shield \u003cbr\u003e• Special PVC outer jacket - black (RAL 9005) \u003cbr\u003e• UV resistant and direct burial approved \u003cbr\u003e• Submersible pump approved \u003cbr\u003e• Extremely oil \u0026amp; chemical resistant\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTechnical:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e• Working voltage: 600\/1000v (UL\/ CSA) \u003cbr\u003e• Working voltage: 1000v (WTTC) \u003cbr\u003e• Test power voltage: 3000 volts \u003cbr\u003e• Flexing bending radius: 7.5 x Ø \u003cbr\u003e• Temperature range: -25º C to +90º C \u003cbr\u003e• Flame retardant: IEC 60332.1-2, FT-4 \u003cbr\u003e• Insulation resistance: 20 MΩ x km\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApprovals: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e• UL type MTW, NFPA 79 2007 \u003cbr\u003e• UL AWM 90 Deg C. \u003cbr\u003e• Class-1, div-2 NEC Art 336,392,501 \u003cbr\u003e• UL TC-ER (tray cable exposed run) \u003cbr\u003e• CSA AWM II A\/B, FT4 - 90 Deg C. \u003cbr\u003e• c(UL) CIC\/TC, FT-4 \u003cbr\u003e• CE Low Voltage Directive 73\/23\/EEC and 93\/68\/EEC \u003cbr\u003e• ROHS compliant\u003c\/p\u003e","brand":"Mueller Cable","offers":[{"title":"Default Title","offer_id":42154892460186,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/iq_01f4e323-1b68-4af0-a5c5-ba7006ceca01.png?v=1759817931"},{"product_id":"type-mc-hl-w-g-copper-conductor-corrugated-aluminum-armored-pvc-ccw-cca-tray-cable-600v","title":"Type MC-HL W\/G Copper Conductor Corrugated Aluminum Armored PVC CCW CCA Tray Cable 600V","description":"\u003cp\u003e\u003cstrong\u003eType MC-HL W\/G Copper Conductor Corrugated Aluminum Armored PVC CCW CCA Tray Cable 600V\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e• Designed for use on power or control circuits\u003cbr\u003e\u003cspan data-mce-fragment=\"1\"\u003e• \u003c\/span\u003eCan be installed in cable tray, wire ways, racks, or buried directly\u003cbr\u003e\u003cspan data-mce-fragment=\"1\"\u003e• \u003c\/span\u003eThis cable has three symmetrically placed grounds to reduce problems associated with pulse-width modulated AC drives\u003cbr\u003e\u003cspan data-mce-fragment=\"1\"\u003e• \u003c\/span\u003eSuitable for VFD applications\u003cbr\u003e\u003cspan data-mce-fragment=\"1\"\u003e• \u003c\/span\u003eSuitable for exposure to hazardous locations, Type MC-HL for Classes I, II, and III Division 1 and 2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e Also Known As:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eType MC-HL Cable, Type MC-HL W\/G Cable, CCW Cable, Continuously Corrugated Welded Wire, CCW PVC Jacketed Cable, Type MC-HL Cable, Metal Clad Hazardous Locations Cables, \u003cspan data-mce-fragment=\"1\"\u003eCCW Tray Cable, CLX Cable, COREFLEX Cable, ARMOR-X Continuously Welded Corrugated, CCA Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003eBare annealed copper per ASTM B-3 10 AWG and smaller are compressed Class B stranding per ASTM B8 8 AWG and larger are compact stranding per ASTM B496\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003eCross-linked Polyethylene (XLPE) type XHHW per UL 44\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003eImpervious, continuously welded and corrugated aluminum alloy sheath\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003eBlack, Polyvinyl Chloride (PVC), sunlight and oil resistant, per UL 1569, 90\u0026amp;deg;C temperature rating\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e• UL 44, XHHW-2\u003cbr\u003e• UL 1309 Marine Shipboard\u003cbr\u003e• UL 1569 Type MC and UL 2225 Type MC-HL\u003cbr\u003e• UL 1581 Designated Type MC as per NEC Article 334 IEEE 1202 available upon request\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e1 Conductor- Black, printed number\u003cbr\u003e\u003cspan data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e2 Conductor- Black, printed number\u003cbr\u003e\u003cspan data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e3 Conductor- Black, printed number\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":42628517527706,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/ccw.png?v=1759818918"},{"product_id":"four-conductor-vfd-cable-600v-1000v","title":"Four Conductor VFD Cable 600V\/1000V","description":"\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eFour Conductor Variable Frequency Drive Cable 600V UL Type TC-ER \/ 1000V UL Type Motor Supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eFour Conductor Variable Frequency Drive Cables are primarily used with VFD’s. The four conductor construction is more effective than the three conductor version to reduce the effects of EMI interference in the event of a component failure. The cable is 600V rated and for use from -40°C to 90°C.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e Stranded soft drawn tinned copper conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDrain(s):\u003c\/strong\u003e Stranded soft drawn tinned copper ground(s).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Cross-linked polyethylene XLPE insulation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShielding:\u003c\/strong\u003e Aluminum polyester \u0026amp; 85% tinned copper braid.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Polyvinyl chloride (PVC) jacket that is sunlight, moisture, oil and abrasion resistant, and direct burial rated.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUL 1277, Type TC-ER, Type XHHW-2\u003cbr\u003eUL approved as 1000V flexible motor supply cable\u003cbr data-mce-fragment=\"1\"\u003eCSA FT-4 Vertical tray flame test\u003cbr data-mce-fragment=\"1\"\u003eCSA AWM I\/II A\/B singles\u003cbr data-mce-fragment=\"1\"\u003eC(UL) CIC-TC per CSA standard C22.2 No. 239 \u0026amp; 230\u003cbr data-mce-fragment=\"1\"\u003eMeets IEEE 1202\/UL 1685 70,000 BTU flame test\u003cbr data-mce-fragment=\"1\"\u003eMeets ICEA T-29-520 210,000 BTU flame test\u003cbr data-mce-fragment=\"1\"\u003eSuitable for use in Class I Division II hazardous locations\u003cbr data-mce-fragment=\"1\"\u003eRoHS II \u0026amp; REACH compliant\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":43753833988250,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/vfdcable4C.jpg?v=1762976466"},{"product_id":"three-conductor-vfd-cable-600v-1000v","title":"Three Conductor VFD Cable 600V\/1000V","description":"\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eThree Conductor Variable Frequency Drive Cable 600V UL Type TC-ER \/ 1000V UL Type Motor Supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThree Conductor Variable Frequency Drive Cables are primarily used with VFD’s. The three conductor construction is suitable for applications that are generally dry with one-phase fault conditions, where an insulated ground is not required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e• 16AWG-4AWG: Stranded soft drawn tinned copper\u003cbr data-mce-fragment=\"1\"\u003e• 2AWG and larger: Stranded soft drawn bare copper\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGround(S):\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e• 16AWG-4AWG: Stranded soft drawn tinned copper\u003cbr\u003e• 2AWG and larger: Stranded soft drawn bare copper\u003c\/p\u003e\n\u003cp\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e• Cross-linked polyethylene (XLP) insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShielding:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e16AWG-4AWG: Aluminum\/Mylar\/Aluminum tape 100%\u003cbr\u003ecoverage \u0026amp; tinned copper braid\u003cbr\u003e• 2AWG and larger: 0.005” helical bare copper tape shield with a\u003cbr\u003e50% overlap\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e• Black polyvinyl chloride (PVC) jacket that is sunlight,\u003cbr\u003emoisture, oil and abrasion resistant, and direct burial rated.\u003cbr\u003e• Rated for use from -40°C to 90°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e• UL 1277, Type TC-ER, Type XHHW-2\u003cbr\u003e• UL approved as 1000V flexible motor supply cable\u003cbr\u003e• UL listed as VFD or WTTC per UL 2277 for Flexible Motor Supply and Wind Turbine Tray Cables\u003cbr\u003e• CSA FT-4 Vertical tray flame test\u003cbr\u003e• CSA AWM I\/II A\/B singles\u003cbr\u003e• CSA Type AWM per CSA standard C22.2 No. 210-11\u003cbr\u003e• c(UL) CIC-TC per CSA standard C22.2 No. 239-09 \u0026amp; 230-09\u003cbr\u003e• Meets UL 1202\/1583 70,000 BTU flame test\u003cbr\u003e• Meets ICEA T-29-520 210,000 BTU flame test\u003cbr\u003e• Suitable for use in Class I Division II hazardous locations\u003cbr\u003e• 90°C DRY\/WET\u003cbr\u003e• RoHS II \u0026amp; REACH compliant\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":43753837625498,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/VFD.jpg?v=1759824282"},{"product_id":"three-conductor-vfd-2kv-cable","title":"Three Conductor VFD 2kV Cable","description":"\u003cp\u003e\u003cstrong\u003eThree Conductor Variable Frequency Drive Cable 2000V UL Type TC-ER\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\" data-mce-style=\"font-size: 0.875rem;\"\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThree Conductor Variable Frequency Drive 2000V Cables are primarily used with AC motors controlled by pulse-width modulated inverter in VFD applications rated up to 2000 Volts. Suitable for installation in cable trays, raceways, or direct burial. They also may be installed in wet or dry locations and are permitted for use in Class I - Div 2, Class II - Div 2, and Class III - Div 1 and 2 industrial hazardous locations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFully annealed bare copper Class B compressed strand per ASTM B-8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGround(S):\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e3 symmetrically placed annealed bare copper conductors in direct contact with shield. Class B stranding per ASTM B-8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHeat and moisture resistant, chemically cross-linked polyethylene (XLPE) insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShielding:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOverall 5 mil annealed bare copper tape shield, helically applied with 50% overlap and 100% coverage\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e•\u003c\/span\u003e Lead-free, flame-retardant polyvinyl chloride (PVC) jacket that is sunlight, weather, chemical and abrasion resistant\u003cbr\u003e• Meets cold bend test at -25°C and crush and impact requirements for Type MC Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e• UL Listed as TC-ER (Exposed Run) per UL Standard 1277 as defined by NEC for 3 or more conductors\u003cbr\u003e• UL Type RHH or RHW-2 conductors per UL 44\u003cbr\u003e• Flame Rated: IEEE (70,000 BTU), IEEE 1202\/CSA FT-4, ICEA T-29-520 (210,000 BTU, 1\/0 AWG and larger), Twohour Firewall\u003cbr\u003e• Rated 90°C wet or dry\u003cbr\u003e• Direct Burial\u003cbr\u003e• Approved for Class 1 and 2, Division 2 and Class 3, Divison\u003cbr\u003e1 and 2 industrial hazardous locations per NEC\u003cbr\u003e• REACH Compliant\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":43753842245786,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/VFD_f03fbf7b-75c0-4cdf-b96d-d14017ae8cf7.jpg?v=1762976467"},{"product_id":"three-conductor-cca-armored-mv-5kv-133-8kv-100-vfd-power-cable-yellow","title":"Three Conductor CCA  Armored MV 5kV 133% \/ 8kV 100% VFD Power Cable Yellow","description":"[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/MV-105_MC-HL_Medium_Voltage.pdf?v=1704123051\"\u003e [\/pdf]\n\u003cp\u003e\u003cstrong\u003eThree Conductor CCA Armored MV 5kV 133% \/ 8kV 100% VFD Power Cable Yellow\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Know As:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThree Conductor CCA Armored Cable, 5kV 133% VFD Power Cable, 8kV 100% VFD Armored Cable, Yellow MV Power Cable, High Voltage VFD CCA Cable, Industrial VFD Power Cable, Yellow CCA VFD Cable, 133% Insulation Level VFD Cable, 100% Insulation Power Cable, Three Phase Armored VFD Cable, Copper Clad Aluminum MV Cable, Heavy Duty VFD Power Cable.\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size: 0.875rem;\" data-mce-style=\"font-size: 0.875rem;\"\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size: 0.875rem;\" data-mce-style=\"font-size: 0.875rem;\"\u003eCCA armored Medium-Voltage power cables are an economical, rugged, and reliable alternative to cable in conduit wiring methods. It is recognized for use on fixed or floating offshore petroleum facilities as recommended by the American Petroleum Institute. CCA cables are for use on feeders and branch circuits in industrial power distribution systems per NEC Articles 328 and 330, as well as for use in Class I, II, and III, Divisions 1 and 2; and Class I, Zones 1 and 2 hazardous locations per NEC Articles 501,502, 503, and 505. They can be installed in both exposed and concealed work, wet or dry locations, directly buried or embedded in concrete, on metal racks, troughs, in raceways, in cable trays or secured to supports spaced not more than six feet apart. 3 conductor CCA armored cables with three (3) symmetrical grounding wires are the preferred wiring method for use with AC motors controlled by pulse-width modulated inverters in VFD applications\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size: 0.875rem;\" data-mce-style=\"font-size: 0.875rem;\"\u003e\u003cstrong\u003eConductors:\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size: 0.875rem;\" data-mce-style=\"font-size: 0.875rem;\"\u003e• Bare, annealed copper Class B compact stranded, in accordance with ASTM B3, B496\u003cbr\u003e• Extruded strand shield of thermoset semi-conductor stress control layer over the conductor per ICEA S-93-639 and UL 1072\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size: 0.875rem;\" data-mce-style=\"font-size: 0.875rem;\"\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size: 0.875rem;\" data-mce-style=\"font-size: 0.875rem;\"\u003e• 115 mils EPR insulation per ICEA S-93-639 and UL 1072 which has outstanding corona resistance and high dielectric strength, and provides electrical stability under stress\u003cbr\u003e• Extruded insulation shield of thermoset, semi-conducting polymeric layer, free stripping from insulation per ICEA S-93- 639 and UL 1072\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size: 0.875rem;\" data-mce-style=\"font-size: 0.875rem;\"\u003e\u003cstrong\u003eGround:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size: 0.875rem;\" data-mce-style=\"font-size: 0.875rem;\"\u003e• Three (3) split bare, annealed copper Class B stranded, sized in accordance with UL 1072 and NEC Article 250\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size: 0.875rem;\" data-mce-style=\"font-size: 0.875rem;\"\u003eShield:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size: 0.875rem;\" data-mce-style=\"font-size: 0.875rem;\"\u003e• 5 mil annealed bare copper tape with 25% overlap\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size: 0.875rem;\" data-mce-style=\"font-size: 0.875rem;\"\u003e\u003cstrong\u003eAssembly:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size: 0.875rem;\" data-mce-style=\"font-size: 0.875rem;\"\u003e• Insulated and grounding conductors are cabled together with non-hygroscopic fillers when required. Binder tape is applied over the cabled core\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size: 0.875rem;\" data-mce-style=\"font-size: 0.875rem;\"\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size: 0.875rem;\" data-mce-style=\"font-size: 0.875rem;\"\u003e• Continuous corrugated and welded, impervious aluminum alloy sheath providing complete protection against moisture, liquid, and gas per UL 1072 and UL 1569. Conductivity meets the grounding requirements of the NEC and UL 1072\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size: 0.875rem;\" data-mce-style=\"font-size: 0.875rem;\"\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size: 0.875rem;\" data-mce-style=\"font-size: 0.875rem;\"\u003e• Yellow flame-retardant, moisture and sunlight-resistant polyvinyl chloride (PVC). Low temperature performance meets ASTM D746\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size: 0.875rem;\" data-mce-style=\"font-size: 0.875rem;\"\u003e\u003cstrong\u003ePhase Id:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size: 0.875rem;\" data-mce-style=\"font-size: 0.875rem;\"\u003e• Color-coded polymeric identification tape laid under the shield black, red, blue\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size: 0.875rem;\" data-mce-style=\"font-size: 0.875rem;\"\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size: 0.875rem;\" data-mce-style=\"font-size: 0.875rem;\"\u003e• Meets UL 1072 for Medium Voltage Power Cables\u003cbr\u003e• Meets UL 1569 requirements for Type MC, Metal Clad Cables\u003cbr\u003e• Meets UL 2225 for Hazardous Locations (MC-HL)\u003cbr\u003e• Meets UL 1309 requirements for Marine Shipboard Cable\u003cbr\u003e• ICEA S-93-639\/WC-74, 5-46 kV Shielded Power Cable\u003cbr\u003e• CSA C68.3\u003cbr\u003e• AEIC CS8 Specification for Shielded Power Cable, 5-46 kV\u003cbr\u003e• UL Type MV-105\u003cbr\u003e• UL Type MC-HL, SUN RES, CT USE, DIR BUR, -40°C, FT4\u003cbr\u003e• Flame Tests: ICEA T-29-520 (210,000 BTU\/hr), IEEE 383 and IEEE 1202 (70,000 BTU\/hr), IEC 60332-3 category A, UL 1072 and CSA FT4\u003cbr\u003e• UL Listed Marine Shipbaord and American Bureau of Shipping (ABS) listed for CWCMC\u003cbr\u003e• 105°C continuous operating temperature, wet or dry. 140°C emergency rating. 250°C short circuit rating.\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":44251602583706,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_19be8aa3-1bfd-4fe0-8f5a-78445cdf3945.jpg?v=1762987136"},{"product_id":"prysmian-airguard-tc-er-hl-low-voltage-vfd-cable-600v","title":"Prysmian Airguard TC-ER- HL Low Voltage VFD Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Prysmian_Airguard.pdf?v=1666969345\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003ePrysmian Airguard TC-ER- HL Low Voltage VFD Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003e• Prysmian’s Low Voltage AIRGUARD Power Cables are primarily designed for applications in environments found in heavy industrial and offshore markets. Its rugged polymeric AIR BAG armor and chemical barrier protection package makes it the ideal cable choice for tough harsh environmental conditions.\u003cbr\u003e• AIRGUARD provides the solution to the deficiencies often encountered with MC-HL cables including armor breakage encountered during installation and in applications requiring recurring bending after installation (as is typical during scheduled maintenance and calibration of controls and instrumentation), as well as poor performance in areas of high vibration (e.g. motor connections). AIRGUARD also provides a safer alternative to MC-HL due to its \"No Knife\/No Saw preparation. Installation cost is reduced as bulky, expensive metallic armor grounding glands are not required.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePrysmian Airguard VFD cable, Airguard TC-ER-HL cable, Low voltage VFD cable 600V, Prysmian 600V VFD cable, TC-ER-HL cable specs, Airguard 600V cable datasheet, Prysmian VFD cable price, Airguard TC-ER-HL VFD 600V, Prysmian low voltage VFD, Prysmian TC-ER-HL features, \u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eStrippability:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eNo Knife!? No Saw? No Problem! The ability to strip a cable quickly without damaging the phase conductors is critical in reducing installation costs. The combination of Low Voltage AIRGUARD’S unique design and strategically placed rip cords allows it to be stripped up to three times faster than Metal Clad cables without the worry of nicked or damaged phase conductors. Low Voltage AIRGUARD cables do not require the use of a saw (as in the case of CCW cables) which results in increased personnel safety and reduces the potential for damage to the underlying core.\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\"\u003e\u003cstrong\u003eChemical Resistance:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eIndustrial plants require cable that will stand up to corrosive chemicals and hydrocarbons. Whether installing in a direct burial application, in tray, or in the air, Low Voltage AIRGUARD’s proprietary polymeric layer provides the best protection in the market for the broadest range of chemicals.\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\"\u003e\u003cstrong\u003eMechanical Resistance:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eAIRGUARD is known for its mechanical strength. When Prysmian’s R\u0026amp;D engineers were designing Prysmian’s new Low Voltage AIRGUARD it was imperative that the traditional toughness of the prior medium voltage designs be passed on to the Low Voltage AIRGUARD. In crush and impact testing, it is proven to be significantly stronger than metallic armored cables.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eFlame:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eNot propagating a fire is a critical design parameter of any cable for the industrial market. Low voltage AIRGUARD passes all the industry standard flame tests, including IEEE 1202, FT-4 and IEEE 383 210,000 BTU flame test.\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\"\u003e\u003cstrong\u003eVFD:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eLow Voltage AIRGUARD VFD cables are designed with three symmetrically placed ground wires and an aluminum or copper sheath to contain the generation of high frequency electromagnetic interference (EMI) imposed on the cable when installed in a circuit containing a Variable Frequency Drive. In the event of catastrophic cable damage, this shield, plus the 3 segmented ground wires, should contain any arcing and effectively conduct system fault current to ground.\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\"\u003e\u003cstrong\u003eProduct Range:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eLow Voltage AIRGUARD is available in 600V Power, Control \u0026amp; Instrumentation, from #16 AWG to 1000 kcmil. Standard stocked items include instrumentation cables, control cables to 37\/C, and power cables to 3\/C 750 kcmil.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eLSOH Option:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\"\u003eAIRGUARD is available in Low Smoke Zero Halogen (LS0H) construction. Add \"LSOH\" to the part number to specify as such.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eStandards: \u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e• ASTM B3 \u0026amp; ASTM B8 Class B Soft Drawn Concentric Lay Stranded Bare Copper Conductors\u003cbr\u003e• S095-658 (NEMA WC70) Cable Rating XHHW-2 Multiple Conductors UL 44 (XHHW-2) 600V Direct Buried Sunlight Resistant Oil Resistant\u003cbr\u003e• IEEE 1202\/FT-4 Flame Retardant IEEE 383\u003cbr\u003e• UL 1277 TC-ER Exposed Run Rating NEC Article 336.10(7)\u003cbr\u003e• UL 2225 TC-ER- HL\u003cbr\u003e• NEC Article 501.10(A)(2)(3) TC-ER- HL Class I Division 1\u003cbr\u003e• NEC Article 505.15(B)(1)(i) TC-ER-HL Class I Zone 1\u003cbr\u003e• CSA 22.2 No. 03 -40°C\/ -35°C Cold Bend\/Cold Impact\u003cbr\u003e• MSHA Mine Safety \u0026amp; Health Administration\u003cbr\u003e• IEEE 1580* Marine Shipboard Cable Rating\u003cbr\u003e• ABS American Bureau of Shipping Type Approval\u003c\/p\u003e\n\u003ch4 class=\"MsoNormal\"\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e• No Knife? No Saw? No Problem!” installation makes terminating \u0026amp; splicing safer for electricians, and it greatly reduces the chances of damage to the conductors.\u003cbr\u003e• Low Voltage AIRGUARD provides users the ease of installation of a tray cable\u003cbr\u003e• Superior crush and impact resistance as compared to MC-HL cables when tested in accordance with UL-2225\u003cbr\u003e• Smaller minimum bending radius as compared to metal clad cables, as low as 4X cable diameter.\u003cbr\u003e• Prysmian’s patented Polymeric AIR BAG armor eliminates the concern of kinking or breaking of corrugated aluminum armor during installation or subsequent bending in service that is often associated with Type MC-HL cables\u003cbr\u003e• Reduced installation costs due to increased flexibility, ease of pulling, faster and safer cable preparation\u003cbr\u003e• Use of less costly cable glands with significantly reduced installation time\u003cbr\u003e• AIR BAG layer provides superior protection from the ingress of harmful fluids, hydrocarbon and chemicals\u003cbr\u003e• Rated for installation in cable tray, for exposed runs (Type TC-ER), conduit, duct, direct burial, and aerial applications in Class I Division 2, Zone 2, and unclassified locations\u003cbr\u003e• Permitted for use in Class I Division 1 and Zone 1 hazardous locations (Type TC-ER-HL) in accordance with National Electrical Code (2014) Sections 501.10(A)\u003cbr\u003e(2)(3) \u0026amp; 505.15(B)(i)\u003cbr\u003e• Rated for -40°C\/ -35°C cold bend\/ cold impact per CSA 22.2 No. 03\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":51645253255537,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/4_18ab03f9-409a-42fe-8576-d092d95581a7.png?v=1759829454"},{"product_id":"three-conductor-type-mc-hl-copper-power-cable-corrugated-welded-armor-lszh-tp-jacket-600v","title":"Three Conductor Type MC-HL Copper Power Cable Corrugated Welded Armor LSZH-TP Jacket 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC45302_1_1_2_1_1.pdf?v=1755666313\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eThree Conductor Type MC-HL Copper Power Cable Corrugated Welded Armor LSZH-TP Jacket 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eType MC-HL ARMOR-X power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, 250°C for short circuit conditions, and -50°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503. Cables with 3 ground wires suitable for VFD application.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThree Type MC-HL copper power cable, Corrugated welded armor MC-HL cable, Low Smoke Zero Halogen MC-HL cable, 600V MC-HL power cable, VFD-rated MC-HL cable, UL Type MC-HL LSZH cable, LSZH-TP jacketed MC-HL cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1569 Metal-Clad Cables\u003cbr\u003e• UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test (1\/0 and Larger)\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 3 (1-BLACK, 2-RED, 3-BLUE)\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and B8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Cross Linked Polyethylene (XLPE) Type XHHW-2\u003cbr\u003e\u003cstrong\u003e• Grounding Conductor: \u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and B8\u003cbr\u003e\u003cstrong\u003e• Filler: \u003c\/strong\u003ePaper filler (cable size 8 \u0026amp; 6 uses Polypropylene filler)\u003cbr\u003e\u003cstrong\u003e• Binder: \u003c\/strong\u003ePolypropylene tape\u003cbr\u003e\u003cstrong\u003e• Armor:\u003c\/strong\u003e ARMOR-X Continuous Corrugated Welded Armor\u003cbr\u003e\u003cstrong\u003e• Overall Jacket: \u003c\/strong\u003eThermoplastic Solonon Low Smoke Zero Halogen (LSZH-TP) Jacket\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55294649794929,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/10-Photoroom.png?v=1763025930"},{"product_id":"type-mc-hl-w-g-corrugated-welded-armor-xlpe-pvc-jacket-vfd-cable-600v","title":"Type MC-HL W\/G Corrugated Welded Armor XLPE\/PVC Jacket VFD Cable 600V","description":"\u003cp\u003e[short] [pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC45226_2_1.pdf?v=1755592307\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eType MC-HL W\/G Corrugated Welded Armor XLPE\/PVC Jacket VFD Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eType MC-HL ARMOR-X control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, 250°C for short circuit conditions. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eMC-HL VFD cable 600V, corrugated welded armor cable, XLPE PVC jacketed VFD cable, MC-HL cable with welded armor, VFD control cable 600V, MC cable XLPE PVC welded armor, corrugated armor VFD cable, XLPE PVC VFD MC cable 600V, welded armor MC-HL VFD cable, 600V MC-HL VFD cable XLPE.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1569 Metal-Clad Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• UL 2225 Cables and Cable-Fittings For Use In Hazardous (Classified) Locations\u003cbr\u003e• CSA C22.2 No. 123 Metal Sheathed Cables\u003cbr\u003e• CSA C22.2 No. 174 Cables in Hazardous Locations\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003e7 strands class B compressed copper per ASTM B3 and B8\u003cstrong\u003e\u003cbr\u003e• Insulation: \u003c\/strong\u003eCross Linked Polyethylene (XLPE) Type XHHW-2\u003cstrong\u003e\u003cbr\u003e• Grounding Conductor: \u003c\/strong\u003e3 Class B compressed stranded bare copper ground per ASTM B3 and B8\u003cstrong\u003e\u003cbr\u003e• Filler: \u003c\/strong\u003ePolypropylene filler on cables with 5 or less conductors\u003cstrong\u003e\u003cbr\u003e• Binder: \u003c\/strong\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cstrong\u003e\u003cbr\u003e• Armor: \u003c\/strong\u003eARMOR-X Continuous Corrugated Welded Armor\u003cstrong\u003e\u003cbr\u003e• Overall Jacket: \u003c\/strong\u003ePolyvinyl Chloride (PVC)\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55742321295729,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/16_143428c9-db2b-46a6-9193-4c45769f91dc.png?v=1755592073"},{"product_id":"type-mc-hl-w-g-corrugated-welded-armor-xlpe-lszh-tp-jacket-vfd-cable-600v","title":"Type MC-HL W\/G Corrugated Welded Armor XLPE\/LSZH-TP Jacket VFD Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC45228_1_2.pdf?v=1755674229\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eType MC-HL W\/G Corrugated Welded Armor XLPE\/LSZH-TP Jacket VFD Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eType MC-HL ARMOR-X control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, 250°C for short circuit conditions, and -50°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503.\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eMC-HL Cable 600V, Corrugated Welded Armor Cable, VFD Cable XLPE\/LSZH, Welded Armor MC Cable, MC-HL VFD 600V Cable, XLPE LSZH Cable VFD, LSZH Jacket MC Cable, 600V VFD Cable, Corrugated Armor Cable MC-HL, VFD Cable with Welded Armor.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1309 Marine Shipboard Cable\u003cbr\u003e• UL 1569 Metal-Clad Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003cbr\u003e• NFPA 130 Standard for Fixed Guideway Transit and Passenger Rail Systems (500kcmil \u0026amp; Larger)\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003e7 strands class B compressed tinned copper per ASTM B33 and B8\u003cstrong\u003e\u003cbr\u003e• Insulation: \u003c\/strong\u003eCross Linked Polyethylene (XLPE) XHHW-2, 30 Mils thick for all cable sizes\u003cstrong\u003e\u003cbr\u003e• Grounding Conductor: \u003c\/strong\u003e3 Class B compressed stranded bare copper ground per ASTM B3 and B8\u003cstrong\u003e\u003cbr\u003e• Filler: \u003c\/strong\u003ePolypropylene filler on cables with 5 or less conductors\u003cstrong\u003e\u003cbr\u003e• Binder: \u003c\/strong\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cstrong\u003e\u003cbr\u003e• Armor: \u003c\/strong\u003eARMOR-X Continuous Corrugated Welded Armor\u003cstrong\u003e\u003cbr\u003e• Overall Jacket: \u003c\/strong\u003eThermoplastic SOLONON Low Smoke Zero Halogen (LSZH-TP) Jacket\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55744100204913,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/17_b5d3f826-ff25-46f1-b3d2-0d0b4abb0119.png?v=1755673813"},{"product_id":"type-mv-105-three-conductor-copper-15kv-nlepr-insulation-133-il-aia-red-lszh-tp-jacket-2","title":"Type MV-105 Three Conductor Copper 15kV NLEPR Insulation 133% IL AIA Red LSZH-TP Jacket","description":"\u003cp\u003e[short] [pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC46460-003_2.pdf?v=1755680365\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003eType MV-105 Three Conductor Copper 15kV NLEPR Insulation 133% IL AIA Red LSZH-TP Jacket\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplication:\u003c\/h3\u003e\n\u003cp\u003eSouthwire’s 15KV cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated at -25°C for cold bend. For uses in Class I and II, Division 2 hazardous locations per NEC Article 501 and 502.Rated for 1000 lbs.\/FT maximum sidewall pressure.\u003c\/p\u003e\n\u003ch3\u003eAlso known as:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"287\" data-start=\"260\"\u003eMetal Clad (MC) Cable Control Cable with Corrugated Steel Armor Welded Armor MC Cable MC-HL (Heat and Light Resistant) Cable XLPE Insulated Control Cable PVC Jacketed Control Cable 600V Rated Control Cable MC-HL Cable with Ground Corrugated Armor MC Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003cbr\u003e\u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and ASTM B8 (Tinned Copper per ASTM B33 optional)\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConductor Shield: \u003cbr\u003e\u003c\/strong\u003eSemi-conducting cross-linked copolymer\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e:\u003cbr\u003e 220 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation Shield: \u003cbr\u003e\u003c\/strong\u003eStrippable semi-conducting cross-linked copolymer\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCopper Tape Shield: \u003c\/strong\u003e\u003cbr\u003eHelically wrapped 5 mil copper tape with 25% overlap\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGrounding Conductor:\u003cbr\u003e\u003c\/strong\u003eClass B compressed stranded bare copper ground per ASTM B3 and ASTM B8 (Tinned Copper per ASTM B33 optional)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFiller\u003c\/strong\u003e:\u003cbr\u003eWax paper filler\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBinder\u003c\/strong\u003e:\u003cbr\u003ePolypropylene tape\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor\u003c\/strong\u003e:\u003cbr\u003eAluminum Interlocked Armor (AIA)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003eThermoplastic SOLONON Low Smoke Zero Halogen (LSZH-TP) \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire\u003cbr\u003e• UL 1072 Medium-Voltage Power Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55744184680817,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/500_1.png?v=1755678844"},{"product_id":"type-mv-105-three-conductor-copper-5-8kv-nlepr-insulation-133-100-il-aia-yellow-lszh-tp-jacket","title":"Type MV-105 Three Conductor Copper 5\/8kV NLEPR Insulation 133\/100% IL AIA Yellow LSZH-TP Jacket","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC46258_1__removed_1.pdf?v=1755848193\" width=\"\" height=\"\" type=\"application\/pdf\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eType MV-105 Three Conductor Copper 5\/8kV NLEPR Insulation 133\/100% IL AIA Yellow LSZH-TP Jacket\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan data-sheets-root=\"1\"\u003eThe 5KV cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated at\u003cbr\u003e-25°C for cold bend. For uses in Class I and II, Division 2 hazardous locations per NEC Article 501 and 502.Rated for 1000 lbs.\/FT maximum sidewall pressure.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eMV-105 copper cable, Three conductor 5\/8kV cable, NLEPR insulation MV cable, AIA copper cable, LSZH-TP jacket cable, 5\/8kV MV cable, Yellow LSZH cable, 133\/100% IL cable, Low smoke zero halogen cable, MV-105 5\/8kV VFD cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire\u003cbr\u003e• UL 1072 Medium-Voltage Power Cables\u003cbr\u003e• UL 1685 FT4-ST1 Vertical-Tray Fire Propagation and Smoke Release Test (1\/0 and Larger)\u003cbr\u003e• ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable\u003cbr\u003e• ICEA S-97-682 Standard for Shielded Utility Cable Rated for 5 - 46kV\u003cbr\u003e• AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)\u003cbr\u003e• Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and ASTM B8 (Tinned Copper per ASTM B33 optional)\u003cstrong\u003e\u003cbr\u003e• Conductor Shield: \u003c\/strong\u003eSemi-conducting cross-linked copolymer\u003cstrong\u003e\u003cbr\u003e• Insulation: \u003c\/strong\u003e115 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level,\u003cstrong\u003e\u003cbr\u003e• Insulation Shield: \u003c\/strong\u003eStrippable semi-conducting cross-linked copolymer\u003cstrong\u003e\u003cbr\u003e• Copper Tape Shield: \u003c\/strong\u003eHelically wrapped 5 mil copper tape with 25% overlap\u003cstrong\u003e\u003cbr\u003e• Grounding Conductor: \u003c\/strong\u003eClass B compressed stranded bare copper ground per ASTM B3 and ASTM B8 (Tinned Copper per ASTM B33 optional)\u003cstrong\u003e\u003cbr\u003e• Filler: \u003c\/strong\u003eWax paper filler\u003cstrong\u003e\u003cbr\u003e• Binder: \u003c\/strong\u003ePolypropylene tape\u003cstrong\u003e\u003cbr\u003e• Armor: \u003c\/strong\u003eAluminum Interlocked Armor (AIA)\u003cstrong\u003e\u003cbr\u003e• Overall Jacket: \u003c\/strong\u003eThermoplastic SOLONON Low Smoke Zero Halogen (LSZH-TP)\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55747952574833,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/4_cf77abd6-5f65-4a30-bc09-e83f5ee41ad5.png?v=1755847997"},{"product_id":"type-mv-105-three-conductor-copper-5-8kv-nlepr-insulation-133-100-il-armor-x-yellow-pvc-jacket","title":"Type MV-105 Three Conductor Copper 5\/8kV NLEPR Insulation 133\/100% IL ARMOR-X Yellow PVC Jacket","description":"\u003cp\u003e[short] [pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/222222_3.pdf?v=1755857387\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003eType MV-105 Three Conductor Copper 5\/8kV NLEPR Insulation 133\/100% IL ARMOR-X Yellow PVC Jacket\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplication\u003cstrong\u003e:\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003eThe 5KV ARMOR-X MC HL are armored cables for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, 250°C for short circuit conditions, and -50°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503. Suitable for VFD application. Rated for 1000 lbs.\/FT maximum sidewall pressure Type MV-105 Three Conductor Copper, 115 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level, Tape Shield, Continuous Corrugated Welded Aluminum Armor - ARMOR-X, Polyvinyl Chloride (PVC) Jacket. Suitable for VFD Applications. Type MC HL. Silicone Free\u003c\/p\u003e\n\u003ch3\u003eAlso known as:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"128\" data-start=\"87\"\u003eMV-105 Three-Conductor Copper Cable 5\/8 kV Three Conductor Cable with NLEPR Insulation Medium Voltage Three-Conductor Copper Cable with Armor-X Protection 133\/100% Insulation, Three-Conductor Copper Cable with Yellow PVC Jacket 5\/8 kV NLEPR Insulated Copper Cable with Armor-X, Yellow PVC Jacket Medium Voltage Copper Cable with IL Armor-X and Yellow PVC Jacket\u003c\/p\u003e\n\u003ch3\u003eConstruction:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003cbr\u003e\u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and B8 (Tinned Copper per ASTM B33 optional)\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConductor Shield:\u003cbr\u003e\u003c\/strong\u003eSemi-conducting cross-linked copolymer\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e:\u003cbr\u003e115 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation Shield: \u003cbr\u003e\u003c\/strong\u003eStrippable semi-conducting cross-linked copolymer\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCopper Tape Shield:\u003cbr\u003e\u003c\/strong\u003eHelically wrapped 5 mil copper tape with 25% overlap\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGrounding Conductor:\u003cbr\u003e\u003c\/strong\u003e3 Class B compressed stranded bare copper ground per ASTM B3 and B8 (Tinned Copper per ASTM B33 optional)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFiller\u003c\/strong\u003e:\u003cbr\u003eWax paper filler\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBinder\u003c\/strong\u003e:\u003cbr\u003e Polypropylene tape\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor\u003c\/strong\u003e:\u003cbr\u003eARMOR-X Continuous Corrugated Welded Aluminum Armor\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003ePolyvinyl Chloride (PVC) \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire\u003cbr\u003e• UL 1072 Medium-Voltage Power Cables\u003cbr\u003e• UL 1569 Metal-Clad Cables\u003cbr\u003e• UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55748021813617,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/500_5.png?v=1755856561"},{"product_id":"type-mv-105-three-conductor-copper-8kv-nlepr-insulation-133-il-armor-x-yellow-pvc-jacket","title":"Type MV-105 Three Conductor Copper 8kV NLEPR Insulation 133% IL ARMOR-X Yellow PVC Jacket","description":"\u003cp\u003e[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC46284_1_1_1.pdf?v=1756096369\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eType MV-105 Three Conductor Copper 8kV NLEPR Insulation 133% IL ARMOR-X Yellow PVC Jacket\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 8KV ARMOR-X are armored cables for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, 250°C for short circuit conditions, and -50°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503. Suitable for VFD application.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eMV-105 cable 8kV, 8kV copper conductor cable, NLEPR insulated medium voltage cable, 133% insulation level MV cable, ARMOR-X cable jacket, Yellow PVC jacketed MV cable, Three conductor MV-105 cable, Medium voltage power cable 8kV, MV-105 copper 133% IL cable, ARMOR-X MV cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B496 Compact Round Concentric-lay-standard copper\u003cbr\u003e• UL 1072 Medium-Voltage Power Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable\u003cbr\u003e• ICEA S-97-682 Standard for Shielded Utility Cable Rated for 5 - 46kV\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003cbr\u003e• AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)\u003cbr\u003e• Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661.\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003c\/strong\u003e Class B compressed stranded bare copper per ASTM B3 and B8 (Tinned copper per ASTM B33 optional)\u003cstrong\u003e\u003cbr\u003e• Conductor Shield: \u003c\/strong\u003eSemi-conducting cross-linked copolymer\u003cstrong\u003e\u003cbr\u003e• Insulation: \u003c\/strong\u003e140 mil No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level\u003cstrong\u003e\u003cbr\u003e• Insulation Shield: \u003c\/strong\u003eStrippable semi-conducting cross-linked copolymer\u003cstrong\u003e\u003cbr\u003e• Copper Tape Shield: \u003c\/strong\u003eHelically wrapped 5 mil copper tape with 25% overlap\u003cstrong\u003e\u003cbr\u003e• Grounding Conductor: \u003c\/strong\u003e3 Class B compressed stranded bare copper ground per ASTM B3 and B8 (Tinned copper per ASTM B33 optional)\u003cstrong\u003e\u003cbr\u003e• Filler: \u003c\/strong\u003eWax paper filler\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e• Binder: \u003c\/strong\u003ePolypropylene tape\u003cstrong\u003e\u003cbr\u003e• Armor: \u003c\/strong\u003eARMOR-X Continuous Corrugated Welded Armor\u003cstrong\u003e\u003cbr\u003e• Overall Jacket: \u003c\/strong\u003eYellow Polyvinyl Chloride (PVC) \u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55752198685041,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/10_95da2c0a-a97a-4fbd-b29b-dc56b800f0db.png?v=1756095953"},{"product_id":"tinned-copper-stranded-tc-er-vfd-flexible-cable-600-1000v","title":"Tinned Copper Stranded TC-ER VFD Flexible Cable 600\/1000V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/TCU_VFD_Cable.pdf?v=1759737613\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003eTinned Copper Stranded TC-ER VFD Flexible Cable 600\/1000V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003ePower supply cable for VFDs and motors, suitable for cable tray, conduit, raceways, (TC-ER) and machine tool wiring conforming to NFPA 79. Suitable for free air and direct burial. Its flexible design is ideal for use on operation processes in accordance with NEC Articles 336, 501 and 502 including, but not limited to: fans, pumps, conveyors, compressors, elevators and lifts, extruders, crushers and presses, assembly lines, food and beverage, wind energy and data centers. Cable is rated for -40C Cold Bend and Impact. Multiple approvals for multiple applications. Machine Flex Type TC-ER Variable Frequency Drive Cable, 600 Volts or 1000 Volts, Tinned Copper Conductors, Cross-Linked Insulation Type RHH\/RHW-2, Thermoplastic Elastomer Jacket, Rated 90°C Dry or Wet, -40°C Cold Impact, Identification Method 4. 1000 Volts Flexible Motor Supply. CSA CIC\/TC FT4 Flame. Sunlight Resistance, Direct Burial, TCU, Silicone Free\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eMachine Flex TCU Cable, VFD Power Cable, Flexible VFD Cable 600 V\/1000 V, TC-ER Rated Variable Frequency Drive Cable, RHH\/RHW-2 Flexible Motor Supply Cable, Shielded XLPE Insulated Tinned Copper VFD Cable, Tray-Rated (UL 1277) Industrial VFD Cable, CSA CIC\/TC FT4 Control and Power Cable, Flexible Motor Lead Cable (WTTC 1000 V), Direct Burial \u0026amp; Sunlight-Resistant VFD Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eClass K flexible stranded tinned annealed copper per ASTM B33, B172, and B174\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003cstrong\u003e• Insulation:\u003c\/strong\u003e\u003cb\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003eCross-linked insulation (Type RHH\/RHW-2 on 14 AWG and larger\u003cbr\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003e•\u003c\/strong\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003e \u003cstrong\u003eGround\u003c\/strong\u003e\u003c\/span\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003e\u003cstrong\u003e:\u003c\/strong\u003e One green ground with yellow stripe cross linked insulation (size equal to phase conductor)\u003cbr\u003e\u003c\/span\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003e•\u003c\/strong\u003e \u003cstrong\u003eDrain Wire:\u003c\/strong\u003e Tinned copper drain wire\u003cbr\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003e•\u003c\/strong\u003e \u003cstrong\u003eShielding:\u003c\/strong\u003e 100% coverage aluminum\/Mylar\/aluminum foil, overall 85% coverage tinned copper braid\u003cbr\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black Thermoplastic Elastomer (TPE) jacket\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B172 Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Copper Conductors\u003cbr\u003e• ASTM B174 Standard Specification for Bunch-Stranded Copper\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 758 Standard for Appliance Wiring Material Style 20886\u003cbr\u003e• UL 1277 Type TC-ER Standard Power and Control Cables (1000V 14AWG and Larger)\u003cbr\u003e• UL 2277 Flexible Motor Supply \u0026amp; Type WTTC\u003cbr\u003e• CSA C22.2 No. 210 Appliance wiring material products I\/II A\/B (Sizes 16 - 8AWG)\u003cbr\u003e• CSA C22.2 No.230 Tray Cables - Rated TC\u003cbr\u003e• CSA C22.2 No. 239 Control and instrumentation cables\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 4\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62411053203825,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-10-06T133414.351.png?v=1759737872"}],"url":"https:\/\/nassaunationalcable.com\/collections\/vfd-cable.oembed?page=2","provider":"NassauNationalCable","version":"1.0","type":"link"}