{"title":"Type MC-HL W\/G Copper Conductor Corrugated Aluminum Armored PVC Tray Cable 600V","description":"","products":[{"product_id":"14-awg-4c-w-g-type-mc-hl-copper-conductor-corrugated-aluminum-armored-pvc-tray-cable-600v","title":"14 AWG 4C W\/G Type MC-HL Copper Conductor Corrugated Aluminum Armored PVC Tray Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/CatalogG5.pdf?v=1729671546\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 4C W\/G Type MC-HL Copper Conductor Corrugated Aluminum Armored PVC Tray Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eAllowable ampacity\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 4C W\/G Type MC-HL Copper Conductor Corrugated Aluminum Armored PVC Tray Cable 600V\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e: 20 amps 90°C Ambient\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3 - 4 copper conductors\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eXLP insulation\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eCopper ground wire\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e• Aerial Installations \u003cbr\u003e• Open Trays\u003cbr\u003e• Direct Burial\u003cbr\u003e• Troughs or continuous rigid cable supports\u003cbr\u003e• Concrete-encased Installations\u003cbr\u003e• Type MC-HL power cable provides an impervious sheath recommended as an economical alternative to traditional conduit systems. It is approved for Classes I, II and III, Division 1 or 2, hazardous locations covered under NEC Articles 501, 502 and 503. The cable is designed with three symmetrically placed grounds to reduce problems associated with pulse-width modulated ac drives. These cables are capable of operating continuously in wet or dry locations at a maximum conductor temperature of 90°C for normal operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eScope:\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003eThis specification covers three or four conductor XLP (cross-linked polyethylene) insulated, continuous corrugated aluminum armored, thermoplastic jacketed, 600 volt cable with grounding conductor for use in aerial installations, metal racks, open trays, troughs or continuous rigid cable supports. The cable will be listed Type MC-HL for Classes I, II and III, Division 1 and 2, hazardous locations and have three symmetrically placed grounds to reduce problems associated with pulse-width modulated ac drives. This cable is capable of operation continuously at a conductor temperature of 90°C in wet or dry locations.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e14 AWG 4C Type MC-HL W\/G Cable, Armored Cable, Tray Cable, 14 AWG 4C MC-HL W\/G Armored Cable, 600V Tray Cable, 14 AWG 4C Aluminum Armored PVC Tray Cable.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe conductor will be Class B compressed concentric stranded bare copper in accordance with ASTM B3 and B8 and ICEA Part 2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe following standards will form part of this specification - ASTM B-8, ICEA S-66-524\/NEMA WC7, UL 44, UL 1569, UL 2225, IEEE 1202, and ICEA T-29-520.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe insulation will be XLP meeting the requirements of the referenced standards. The insulation thickness will be listed in ICEA Table 3.1, and the minimum spot thickness will not be less than 90% of the listed amounts. Individual conductors will be color coded per ICEA S-58-679, using Method 3, Table 2 for sizes AWG 4 and larger, and using Method 1, Table 2 for sizes AWG 6 and smaller.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAssembly:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003eThe insulated conductors will be cabled round with three symmetrically placed ground wires, fillers and covered with a binder tape\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eContinuous corrugated aluminum sheath shall be applied over the assembly. The continuous sheath will be impervious to moisture, liquids, \u0026amp; gasses\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable will be covered with a black PVC jacket conforming to the requirements specified for polyvinyl chloride in ICEA. The average thickness will be in accordance with ICEA, and the minimum spot thickness will not be less than 80% of the average thickness. The jacket will be sunlight and oil resistant and will meet the requirements of the IEEE 1202 (70,000 Btu\/hr) and ICEA T-29-520 (210,000 Btu\/hr) vertical cable tray flame tests. The jacket will be suitable for use at a minimum ambient temperature of -40°C.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIdentification:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eManufacturer's identification will be printed on the jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 14 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Number of  Conductors:\u003c\/strong\u003e\u003cspan\u003e 4\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 0.071\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (In):\u003c\/strong\u003e 0.030\u003cbr\u003e\u003cstrong\u003e• Approx. Core Diameter (In):\u003c\/strong\u003e 0.336\u003cbr\u003e\u003cstrong\u003e• Grounds No. x AWG:\u003c\/strong\u003e 3 x 18 \u003cbr\u003e\u003cstrong\u003e• Armored Diameter (In):\u003c\/strong\u003e 0.56\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (In):\u003c\/strong\u003e 0.060\u003cbr\u003e\u003cstrong\u003e• Approx. Overall Diameter (In):\u003c\/strong\u003e 0.68 \u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:\u003c\/strong\u003e 20\u003cbr\u003e\u003cstrong\u003e• Approx Net Weight lbs.\/Mft. :\u003c\/strong\u003e 225\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":51648544702833,"sku":"NNC070150","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_255ace92-418b-452c-989d-5b15d784cb59.png?v=1763008193"},{"product_id":"12-awg-4c-w-g-type-mc-hl-copper-conductor-corrugated-aluminum-armored-pvc-tray-cable-600v","title":"12 AWG 4C W\/G Type MC-HL Copper Conductor Corrugated Aluminum Armored PVC Tray Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/CatalogG5.pdf?v=1729671546\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 4C W\/G Type MC-HL Copper Conductor Corrugated Aluminum Armored PVC Tray Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eAllowable ampacity\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 4C W\/G Type MC-HL Copper Conductor Corrugated Aluminum Armored PVC Tray Cable 600V\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e: 24 amps 90°C Ambient\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3 - 4 copper conductors\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eXLP insulation\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eCopper ground wire\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e• Aerial Installations \u003cbr\u003e• Open Trays\u003cbr\u003e• Direct Burial\u003cbr\u003e• Troughs or continuous rigid cable supports\u003cbr\u003e• Concrete-encased Installations\u003cbr\u003e• Type MC-HL power cable provides an impervious sheath recommended as an economical alternative to traditional conduit systems. It is approved for Classes I, II and III, Division 1 or 2, hazardous locations covered under NEC Articles 501, 502 and 503. The cable is designed with three symmetrically placed grounds to reduce problems associated with pulse-width modulated ac drives. These cables are capable of operating continuously in wet or dry locations at a maximum conductor temperature of 90°C for normal operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eScope:\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003eThis specification covers three or four conductor XLP (cross-linked polyethylene) insulated, continuous corrugated aluminum armored, thermoplastic jacketed, 600 volt cable with grounding conductor for use in aerial installations, metal racks, open trays, troughs or continuous rigid cable supports. The cable will be listed Type MC-HL for Classes I, II and III, Division 1 and 2, hazardous locations and have three symmetrically placed grounds to reduce problems associated with pulse-width modulated ac drives. This cable is capable of operation continuously at a conductor temperature of 90°C in wet or dry locations.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e12 AWG 4C Type MC-HL W\/G Cable, Armored Cable, Tray Cable, 12 AWG 4C MC-HL W\/G Armored Cable, 600V Tray Cable, 12 AWG 4C Aluminum Armored PVC Tray Cable.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe conductor will be Class B compressed concentric stranded bare copper in accordance with ASTM B3 and B8 and ICEA Part 2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe following standards will form part of this specification - ASTM B-8, ICEA S-66-524\/NEMA WC7, UL 44, UL 1569, UL 2225, IEEE 1202, and ICEA T-29-520.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe insulation will be XLP meeting the requirements of the referenced standards. The insulation thickness will be listed in ICEA Table 3.1, and the minimum spot thickness will not be less than 90% of the listed amounts. Individual conductors will be color coded per ICEA S-58-679, using Method 3, Table 2 for sizes AWG 4 and larger, and using Method 1, Table 2 for sizes AWG 6 and smaller.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAssembly:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003eThe insulated conductors will be cabled round with three symmetrically placed ground wires, fillers and covered with a binder tape\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eContinuous corrugated aluminum sheath shall be applied over the assembly. The continuous sheath will be impervious to moisture, liquids, \u0026amp; gasses\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable will be covered with a black PVC jacket conforming to the requirements specified for polyvinyl chloride in ICEA. The average thickness will be in accordance with ICEA, and the minimum spot thickness will not be less than 80% of the average thickness. The jacket will be sunlight and oil resistant and will meet the requirements of the IEEE 1202 (70,000 Btu\/hr) and ICEA T-29-520 (210,000 Btu\/hr) vertical cable tray flame tests. The jacket will be suitable for use at a minimum ambient temperature of -40°C.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIdentification:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eManufacturer's identification will be printed on the jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 12 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Number of  Conductors:\u003c\/strong\u003e\u003cspan\u003e 4\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 0.089\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (In):\u003c\/strong\u003e 0.030\u003cbr\u003e\u003cstrong\u003e• Approx. Core Diameter (In):\u003c\/strong\u003e 0.380\u003cbr\u003e\u003cstrong\u003e• Grounds No. x AWG:\u003c\/strong\u003e 3 x 16\u003cbr\u003e\u003cstrong\u003e• Armored Diameter (In):\u003c\/strong\u003e 0.60\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (In):\u003c\/strong\u003e 0.060\u003cbr\u003e\u003cstrong\u003e• Approx. Overall Diameter (In):\u003c\/strong\u003e 0.72 \u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:\u003c\/strong\u003e 24\u003cbr\u003e\u003cstrong\u003e• Approx Net Weight lbs.\/Mft.:\u003c\/strong\u003e 279\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":51648546275697,"sku":"NNC070151","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_60d20044-0214-4e51-9c96-b2e994db5476.png?v=1763008196"},{"product_id":"10-awg-4c-w-g-type-mc-hl-copper-conductor-corrugated-aluminum-armored-pvc-tray-cable-600v","title":"10 AWG 4C W\/G Type MC-HL Copper Conductor Corrugated Aluminum Armored PVC Tray Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/CatalogG5.pdf?v=1729671546\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e10 AWG 4C W\/G Type MC-HL Copper Conductor Corrugated Aluminum Armored PVC Tray Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eAllowable ampacity\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e10 AWG 4C W\/G Type MC-HL Copper Conductor Corrugated Aluminum Armored PVC Tray Cable 600V\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e: 32 amps 90°C Ambient\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3 - 4 copper conductors\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eXLP insulation\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eCopper ground wire\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e• Aerial Installations \u003cbr\u003e• Open Trays\u003cbr\u003e• Direct Burial\u003cbr\u003e• Troughs or continuous rigid cable supports\u003cbr\u003e• Concrete-encased Installations\u003cbr\u003e• Type MC-HL power cable provides an impervious sheath recommended as an economical alternative to traditional conduit systems. It is approved for Classes I, II and III, Division 1 or 2, hazardous locations covered under NEC Articles 501, 502 and 503. The cable is designed with three symmetrically placed grounds to reduce problems associated with pulse-width modulated ac drives. These cables are capable of operating continuously in wet or dry locations at a maximum conductor temperature of 90°C for normal operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eScope:\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003eThis specification covers three or four conductor XLP (cross-linked polyethylene) insulated, continuous corrugated aluminum armored, thermoplastic jacketed, 600 volt cable with grounding conductor for use in aerial installations, metal racks, open trays, troughs or continuous rigid cable supports. The cable will be listed Type MC-HL for Classes I, II and III, Division 1 and 2, hazardous locations and have three symmetrically placed grounds to reduce problems associated with pulse-width modulated ac drives. This cable is capable of operation continuously at a conductor temperature of 90°C in wet or dry locations.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e10 AWG 4C Type MC-HL W\/G Cable, Armored Cable, Tray Cable, 10 AWG 4C MC-HL W\/G Armored Cable, 600V Tray Cable, 10 AWG 4C Aluminum Armored PVC Tray Cable.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe conductor will be Class B compressed concentric stranded bare copper in accordance with ASTM B3 and B8 and ICEA Part 2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe following standards will form part of this specification - ASTM B-8, ICEA S-66-524\/NEMA WC7, UL 44, UL 1569, UL 2225, IEEE 1202, and ICEA T-29-520.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe insulation will be XLP meeting the requirements of the referenced standards. The insulation thickness will be listed in ICEA Table 3.1, and the minimum spot thickness will not be less than 90% of the listed amounts. Individual conductors will be color coded per ICEA S-58-679, using Method 3, Table 2 for sizes AWG 4 and larger, and using Method 1, Table 2 for sizes AWG 6 and smaller.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAssembly:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003eThe insulated conductors will be cabled round with three symmetrically placed ground wires, fillers and covered with a binder tape\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eContinuous corrugated aluminum sheath shall be applied over the assembly. The continuous sheath will be impervious to moisture, liquids, \u0026amp; gasses\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable will be covered with a black PVC jacket conforming to the requirements specified for polyvinyl chloride in ICEA. The average thickness will be in accordance with ICEA, and the minimum spot thickness will not be less than 80% of the average thickness. The jacket will be sunlight and oil resistant and will meet the requirements of the IEEE 1202 (70,000 Btu\/hr) and ICEA T-29-520 (210,000 Btu\/hr) vertical cable tray flame tests. The jacket will be suitable for use at a minimum ambient temperature of -40°C.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIdentification:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eManufacturer's identification will be printed on the jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 10 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Number of  Conductors:\u003c\/strong\u003e\u003cspan\u003e 4\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 0.112\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (In):\u003c\/strong\u003e 0.030\u003cbr\u003e\u003cstrong\u003e• Approx. Core Diameter (In):\u003c\/strong\u003e 0.436\u003cbr\u003e\u003cstrong\u003e• Grounds No. x AWG:\u003c\/strong\u003e 3 x 14\u003cbr\u003e\u003cstrong\u003e• Armored Diameter (In):\u003c\/strong\u003e 0.64 \u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (In):\u003c\/strong\u003e 0.060\u003cbr\u003e\u003cstrong\u003e• Approx. Overall Diameter (In):\u003c\/strong\u003e 0.76 \u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:\u003c\/strong\u003e 32\u003cbr\u003e\u003cstrong\u003e• Approx Net Weight lbs.\/Mft.:\u003c\/strong\u003e 358\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":51648547225969,"sku":"NNC070152","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_a4b86d83-8164-48c6-8f4c-0e6a3a0dc0e7.png?v=1763008198"},{"product_id":"8-awg-4c-w-g-type-mc-hl-copper-conductor-corrugated-aluminum-armored-pvc-tray-cable-600v","title":"8 AWG 4C W\/G Type MC-HL Copper Conductor Corrugated Aluminum Armored PVC Tray Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/CatalogG5.pdf?v=1729671546\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e8 AWG 4C W\/G Type MC-HL Copper Conductor Corrugated Aluminum Armored PVC Tray Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eAllowable ampacity\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e8 AWG 4C W\/G Type MC-HL Copper Conductor Corrugated Aluminum Armored PVC Tray Cable 600V\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e: 44 amps 90°C Ambient\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3 - 4 copper conductors\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eXLP insulation\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eCopper ground wire\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e• Aerial Installations \u003cbr\u003e• Open Trays\u003cbr\u003e• Direct Burial\u003cbr\u003e• Troughs or continuous rigid cable supports\u003cbr\u003e• Concrete-encased Installations\u003cbr\u003e• Type MC-HL power cable provides an impervious sheath recommended as an economical alternative to traditional conduit systems. It is approved for Classes I, II and III, Division 1 or 2, hazardous locations covered under NEC Articles 501, 502 and 503. The cable is designed with three symmetrically placed grounds to reduce problems associated with pulse-width modulated ac drives. These cables are capable of operating continuously in wet or dry locations at a maximum conductor temperature of 90°C for normal operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eScope:\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003eThis specification covers three or four conductor XLP (cross-linked polyethylene) insulated, continuous corrugated aluminum armored, thermoplastic jacketed, 600 volt cable with grounding conductor for use in aerial installations, metal racks, open trays, troughs or continuous rigid cable supports. The cable will be listed Type MC-HL for Classes I, II and III, Division 1 and 2, hazardous locations and have three symmetrically placed grounds to reduce problems associated with pulse-width modulated ac drives. This cable is capable of operation continuously at a conductor temperature of 90°C in wet or dry locations.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e8 AWG 4C Type MC-HL W\/G Cable, Armored Cable, Tray Cable, 8 AWG 4C MC-HL W\/G Armored Cable, 600V Tray Cable, 8 AWG 4C Aluminum Armored PVC Tray Cable.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe conductor will be Class B compressed concentric stranded bare copper in accordance with ASTM B3 and B8 and ICEA Part 2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe following standards will form part of this specification - ASTM B-8, ICEA S-66-524\/NEMA WC7, UL 44, UL 1569, UL 2225, IEEE 1202, and ICEA T-29-520.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe insulation will be XLP meeting the requirements of the referenced standards. The insulation thickness will be listed in ICEA Table 3.1, and the minimum spot thickness will not be less than 90% of the listed amounts. Individual conductors will be color coded per ICEA S-58-679, using Method 3, Table 2 for sizes AWG 4 and larger, and using Method 1, Table 2 for sizes AWG 6 and smaller.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAssembly:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003eThe insulated conductors will be cabled round with three symmetrically placed ground wires, fillers and covered with a binder tape\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eContinuous corrugated aluminum sheath shall be applied over the assembly. The continuous sheath will be impervious to moisture, liquids, \u0026amp; gasses\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable will be covered with a black PVC jacket conforming to the requirements specified for polyvinyl chloride in ICEA. The average thickness will be in accordance with ICEA, and the minimum spot thickness will not be less than 80% of the average thickness. The jacket will be sunlight and oil resistant and will meet the requirements of the IEEE 1202 (70,000 Btu\/hr) and ICEA T-29-520 (210,000 Btu\/hr) vertical cable tray flame tests. The jacket will be suitable for use at a minimum ambient temperature of -40°C.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIdentification:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eManufacturer's identification will be printed on the jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 8 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Number of  Conductors:\u003c\/strong\u003e\u003cspan\u003e 4\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 0.141\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (In):\u003c\/strong\u003e 0.045\u003cbr\u003e\u003cstrong\u003e• Approx. Core Diameter (In):\u003c\/strong\u003e 0.587\u003cbr\u003e\u003cstrong\u003e• Grounds No. x AWG:\u003c\/strong\u003e 1 x 10\u003cbr\u003e\u003cstrong\u003e• Armored Diameter (In):\u003c\/strong\u003e 0.83\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (In):\u003c\/strong\u003e 0.060\u003cbr\u003e\u003cstrong\u003e• Approx. Overall Diameter (In):\u003c\/strong\u003e 0.95\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:\u003c\/strong\u003e 44\u003cbr\u003e\u003cstrong\u003e• Approx Net Weight lbs.\/Mft.:\u003c\/strong\u003e 507\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":51648547455345,"sku":"NNC070153","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_782c6ad1-7a2d-4677-bd67-33d46616abe7.png?v=1763008199"},{"product_id":"6-awg-4c-w-g-type-mc-hl-copper-conductor-corrugated-aluminum-armored-pvc-tray-cable-600v","title":"6 AWG 4C W\/G Type MC-HL Copper Conductor Corrugated Aluminum Armored PVC Tray Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/CatalogG5.pdf?v=1729671546\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e6 AWG 4C W\/G Type MC-HL Copper Conductor Corrugated Aluminum Armored PVC Tray Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eAllowable ampacity\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e6 AWG 4C W\/G Type MC-HL Copper Conductor Corrugated Aluminum Armored PVC Tray Cable 600V\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e: 44 amps 90°C Ambient\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3 - 4 copper conductors\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eXLP insulation\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eCopper ground wire\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e• Aerial Installations \u003cbr\u003e• Open Trays\u003cbr\u003e• Direct Burial\u003cbr\u003e• Troughs or continuous rigid cable supports\u003cbr\u003e• Concrete-encased Installations\u003cbr\u003e• Type MC-HL power cable provides an impervious sheath recommended as an economical alternative to traditional conduit systems. It is approved for Classes I, II and III, Division 1 or 2, hazardous locations covered under NEC Articles 501, 502 and 503. The cable is designed with three symmetrically placed grounds to reduce problems associated with pulse-width modulated ac drives. These cables are capable of operating continuously in wet or dry locations at a maximum conductor temperature of 90°C for normal operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eScope:\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003eThis specification covers three or four conductor XLP (cross-linked polyethylene) insulated, continuous corrugated aluminum armored, thermoplastic jacketed, 600 volt cable with grounding conductor for use in aerial installations, metal racks, open trays, troughs or continuous rigid cable supports. The cable will be listed Type MC-HL for Classes I, II and III, Division 1 and 2, hazardous locations and have three symmetrically placed grounds to reduce problems associated with pulse-width modulated ac drives. This cable is capable of operation continuously at a conductor temperature of 90°C in wet or dry locations.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e6 AWG 4C Type MC-HL W\/G Cable, Armored Cable, Tray Cable, 6 AWG 4C MC-HL W\/G Armored Cable, 600V Tray Cable, 6 AWG 4C Aluminum Armored PVC Tray Cable.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe conductor will be Class B compressed concentric stranded bare copper in accordance with ASTM B3 and B8 and ICEA Part 2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe following standards will form part of this specification - ASTM B-8, ICEA S-66-524\/NEMA WC7, UL 44, UL 1569, UL 2225, IEEE 1202, and ICEA T-29-520.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe insulation will be XLP meeting the requirements of the referenced standards. The insulation thickness will be listed in ICEA Table 3.1, and the minimum spot thickness will not be less than 90% of the listed amounts. Individual conductors will be color coded per ICEA S-58-679, using Method 3, Table 2 for sizes AWG 4 and larger, and using Method 1, Table 2 for sizes AWG 6 and smaller.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAssembly:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003eThe insulated conductors will be cabled round with three symmetrically placed ground wires, fillers and covered with a binder tape\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eContinuous corrugated aluminum sheath shall be applied over the assembly. The continuous sheath will be impervious to moisture, liquids, \u0026amp; gasses\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable will be covered with a black PVC jacket conforming to the requirements specified for polyvinyl chloride in ICEA. The average thickness will be in accordance with ICEA, and the minimum spot thickness will not be less than 80% of the average thickness. The jacket will be sunlight and oil resistant and will meet the requirements of the IEEE 1202 (70,000 Btu\/hr) and ICEA T-29-520 (210,000 Btu\/hr) vertical cable tray flame tests. The jacket will be suitable for use at a minimum ambient temperature of -40°C.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIdentification:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eManufacturer's identification will be printed on the jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 6 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Number of  Conductors:\u003c\/strong\u003e\u003cspan\u003e 4\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 0.178 \u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (In):\u003c\/strong\u003e 0.045\u003cbr\u003e\u003cstrong\u003e• Approx. Core Diameter (In):\u003c\/strong\u003e 0.676\u003cbr\u003e\u003cstrong\u003e• Grounds No. x AWG:\u003c\/strong\u003e 1 x 8\u003cbr\u003e\u003cstrong\u003e• Armored Diameter (In):\u003c\/strong\u003e 0.91\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (In):\u003c\/strong\u003e 0.060\u003cbr\u003e\u003cstrong\u003e• Approx. Overall Diameter (In):\u003c\/strong\u003e 1.03\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:\u003c\/strong\u003e 60\u003cbr\u003e\u003cstrong\u003e• Approx Net Weight lbs.\/Mft.:\u003c\/strong\u003e 683\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":51648549159281,"sku":"NNC070154","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_c64f1591-ed77-47d6-9b70-165a96275eea.png?v=1759829520"},{"product_id":"4-awg-4c-w-g-type-mc-hl-copper-conductor-corrugated-aluminum-armored-pvc-tray-cable-600v-1","title":"4 AWG 4C W\/G Type MC-HL Copper Conductor Corrugated Aluminum Armored PVC Tray Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/CatalogG5.pdf?v=1729671546\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e4 AWG 4C W\/G Type MC-HL Copper Conductor Corrugated Aluminum Armored PVC Tray Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eAllowable ampacity\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e4 AWG 4C W\/G Type MC-HL Copper Conductor Corrugated Aluminum Armored PVC Tray Cable 600V\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e: 76 amps 90°C Ambient\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3 - 4 copper conductors\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eXLP insulation\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eCopper ground wire\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e• Aerial Installations \u003cbr\u003e• Open Trays\u003cbr\u003e• Direct Burial\u003cbr\u003e• Troughs or continuous rigid cable supports\u003cbr\u003e• Concrete-encased Installations\u003cbr\u003e• Type MC-HL power cable provides an impervious sheath recommended as an economical alternative to traditional conduit systems. It is approved for Classes I, II and III, Division 1 or 2, hazardous locations covered under NEC Articles 501, 502 and 503. The cable is designed with three symmetrically placed grounds to reduce problems associated with pulse-width modulated ac drives. These cables are capable of operating continuously in wet or dry locations at a maximum conductor temperature of 90°C for normal operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eScope:\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003eThis specification covers three or four conductor XLP (cross-linked polyethylene) insulated, continuous corrugated aluminum armored, thermoplastic jacketed, 600 volt cable with grounding conductor for use in aerial installations, metal racks, open trays, troughs or continuous rigid cable supports. The cable will be listed Type MC-HL for Classes I, II and III, Division 1 and 2, hazardous locations and have three symmetrically placed grounds to reduce problems associated with pulse-width modulated ac drives. This cable is capable of operation continuously at a conductor temperature of 90°C in wet or dry locations.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e4 AWG 4C Type MC-HL W\/G Cable, Armored Cable, Tray Cable, 4 AWG 4C MC-HL W\/G Armored Cable, 600V Tray Cable, 4 AWG 4C Aluminum Armored PVC Tray Cable.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe conductor will be Class B compressed concentric stranded bare copper in accordance with ASTM B3 and B8 and ICEA Part 2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe following standards will form part of this specification - ASTM B-8, ICEA S-66-524\/NEMA WC7, UL 44, UL 1569, UL 2225, IEEE 1202, and ICEA T-29-520.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe insulation will be XLP meeting the requirements of the referenced standards. The insulation thickness will be listed in ICEA Table 3.1, and the minimum spot thickness will not be less than 90% of the listed amounts. Individual conductors will be color coded per ICEA S-58-679, using Method 3, Table 2 for sizes AWG 4 and larger, and using Method 1, Table 2 for sizes AWG 6 and smaller.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAssembly:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003eThe insulated conductors will be cabled round with three symmetrically placed ground wires, fillers and covered with a binder tape\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eContinuous corrugated aluminum sheath shall be applied over the assembly. The continuous sheath will be impervious to moisture, liquids, \u0026amp; gasses\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable will be covered with a black PVC jacket conforming to the requirements specified for polyvinyl chloride in ICEA. The average thickness will be in accordance with ICEA, and the minimum spot thickness will not be less than 80% of the average thickness. The jacket will be sunlight and oil resistant and will meet the requirements of the IEEE 1202 (70,000 Btu\/hr) and ICEA T-29-520 (210,000 Btu\/hr) vertical cable tray flame tests. The jacket will be suitable for use at a minimum ambient temperature of -40°C.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIdentification:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eManufacturer's identification will be printed on the jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 4 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Number of  Conductors:\u003c\/strong\u003e\u003cspan\u003e 4\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 0.225\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (In):\u003c\/strong\u003e 0.045\u003cbr\u003e\u003cstrong\u003e• Approx. Core Diameter (In):\u003c\/strong\u003e 0.799\u003cbr\u003e\u003cstrong\u003e• Grounds No. x AWG:\u003c\/strong\u003e 1 x 8\u003cbr\u003e\u003cstrong\u003e• Armored Diameter (In):\u003c\/strong\u003e 1.05 \u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (In):\u003c\/strong\u003e 0.060\u003cbr\u003e\u003cstrong\u003e• Approx. Overall Diameter (In):\u003c\/strong\u003e 1.17 \u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:\u003c\/strong\u003e 76\u003cbr\u003e\u003cstrong\u003e• Approx Net Weight lbs.\/Mft.:\u003c\/strong\u003e 919 \u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":51648550109553,"sku":"NNC070155","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_dd0cb7b9-9229-44c0-ba65-e26059e1b40a.png?v=1759829521"},{"product_id":"2-awg-4c-w-g-type-mc-hl-copper-conductor-corrugated-aluminum-armored-pvc-tray-cable-600v","title":"2 AWG 4C W\/G Type MC-HL Copper Conductor Corrugated Aluminum Armored PVC Tray Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/CatalogG5.pdf?v=1729671546\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2 AWG 4C W\/G Type MC-HL Copper Conductor Corrugated Aluminum Armored PVC Tray Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eAllowable ampacity\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e2 AWG 4C W\/G Type MC-HL Copper Conductor Corrugated Aluminum Armored PVC Tray Cable 600V\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e: 104 amps 90°C Ambient\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3 - 4 copper conductors\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eXLP insulation\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eCopper ground wire\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e• Aerial Installations \u003cbr\u003e• Open Trays\u003cbr\u003e• Direct Burial\u003cbr\u003e• Troughs or continuous rigid cable supports\u003cbr\u003e• Concrete-encased Installations\u003cbr\u003e• Type MC-HL power cable provides an impervious sheath recommended as an economical alternative to traditional conduit systems. It is approved for Classes I, II and III, Division 1 or 2, hazardous locations covered under NEC Articles 501, 502 and 503. The cable is designed with three symmetrically placed grounds to reduce problems associated with pulse-width modulated ac drives. These cables are capable of operating continuously in wet or dry locations at a maximum conductor temperature of 90°C for normal operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eScope:\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003eThis specification covers three or four conductor XLP (cross-linked polyethylene) insulated, continuous corrugated aluminum armored, thermoplastic jacketed, 600 volt cable with grounding conductor for use in aerial installations, metal racks, open trays, troughs or continuous rigid cable supports. The cable will be listed Type MC-HL for Classes I, II and III, Division 1 and 2, hazardous locations and have three symmetrically placed grounds to reduce problems associated with pulse-width modulated ac drives. This cable is capable of operation continuously at a conductor temperature of 90°C in wet or dry locations.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e2 AWG 4C Type MC-HL W\/G Cable, Armored Cable, Tray Cable, 2 AWG 4C MC-HL W\/G Armored Cable, 600V Tray Cable, 2 AWG 4C Aluminum Armored PVC Tray Cable.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe conductor will be Class B compressed concentric stranded bare copper in accordance with ASTM B3 and B8 and ICEA Part 2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe following standards will form part of this specification - ASTM B-8, ICEA S-66-524\/NEMA WC7, UL 44, UL 1569, UL 2225, IEEE 1202, and ICEA T-29-520.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe insulation will be XLP meeting the requirements of the referenced standards. The insulation thickness will be listed in ICEA Table 3.1, and the minimum spot thickness will not be less than 90% of the listed amounts. Individual conductors will be color coded per ICEA S-58-679, using Method 3, Table 2 for sizes AWG 4 and larger, and using Method 1, Table 2 for sizes AWG 6 and smaller.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAssembly:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003eThe insulated conductors will be cabled round with three symmetrically placed ground wires, fillers and covered with a binder tape\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eContinuous corrugated aluminum sheath shall be applied over the assembly. The continuous sheath will be impervious to moisture, liquids, \u0026amp; gasses\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable will be covered with a black PVC jacket conforming to the requirements specified for polyvinyl chloride in ICEA. The average thickness will be in accordance with ICEA, and the minimum spot thickness will not be less than 80% of the average thickness. The jacket will be sunlight and oil resistant and will meet the requirements of the IEEE 1202 (70,000 Btu\/hr) and ICEA T-29-520 (210,000 Btu\/hr) vertical cable tray flame tests. The jacket will be suitable for use at a minimum ambient temperature of -40°C.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIdentification:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eManufacturer's identification will be printed on the jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Number of  Conductors:\u003c\/strong\u003e\u003cspan\u003e 4\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 0.283\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (In):\u003c\/strong\u003e 0.045\u003cbr\u003e\u003cstrong\u003e• Approx. Core Diameter (In):\u003c\/strong\u003e 0.940 \u003cbr\u003e\u003cstrong\u003e• Grounds No. x AWG:\u003c\/strong\u003e 1 x 6 \u003cbr\u003e\u003cstrong\u003e• Armored Diameter (In):\u003c\/strong\u003e 1.30\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (In):\u003c\/strong\u003e 0.060\u003cbr\u003e\u003cstrong\u003e• Approx. Overall Diameter (In):\u003c\/strong\u003e 1.42 \u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:\u003c\/strong\u003e 104\u003cbr\u003e\u003cstrong\u003e• Approx Net Weight lbs.\/Mft.:\u003c\/strong\u003e 1356 \u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":51648574882161,"sku":"NNC070156","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_ab946da6-f0fe-4d2a-8528-8e2e968caa5b.png?v=1763008231"},{"product_id":"1-awg-4c-w-g-type-mc-hl-copper-conductor-corrugated-aluminum-armored-pvc-tray-cable-600v","title":"1 AWG 4C W\/G Type MC-HL Copper Conductor Corrugated Aluminum Armored PVC Tray Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/CatalogG5.pdf?v=1729671546\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1 AWG 4C W\/G Type MC-HL Copper Conductor Corrugated Aluminum Armored PVC Tray Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eAllowable ampacity\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e1 AWG 4C W\/G Type MC-HL Copper Conductor Corrugated Aluminum Armored PVC Tray Cable 600V\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e: 120 amps 90°C Ambient\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3 - 4 copper conductors\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eXLP insulation\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eCopper ground wire\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e• Aerial Installations \u003cbr\u003e• Open Trays\u003cbr\u003e• Direct Burial\u003cbr\u003e• Troughs or continuous rigid cable supports\u003cbr\u003e• Concrete-encased Installations\u003cbr\u003e• Type MC-HL power cable provides an impervious sheath recommended as an economical alternative to traditional conduit systems. It is approved for Classes I, II and III, Division 1 or 2, hazardous locations covered under NEC Articles 501, 502 and 503. The cable is designed with three symmetrically placed grounds to reduce problems associated with pulse-width modulated ac drives. These cables are capable of operating continuously in wet or dry locations at a maximum conductor temperature of 90°C for normal operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eScope:\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003eThis specification covers three or four conductor XLP (cross-linked polyethylene) insulated, continuous corrugated aluminum armored, thermoplastic jacketed, 600 volt cable with grounding conductor for use in aerial installations, metal racks, open trays, troughs or continuous rigid cable supports. The cable will be listed Type MC-HL for Classes I, II and III, Division 1 and 2, hazardous locations and have three symmetrically placed grounds to reduce problems associated with pulse-width modulated ac drives. This cable is capable of operation continuously at a conductor temperature of 90°C in wet or dry locations.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1 AWG 4C Type MC-HL W\/G Cable, Armored Cable, Tray Cable, 1 AWG 4C MC-HL W\/G Armored Cable, 600V Tray Cable, 1 AWG 4C Aluminum Armored PVC Tray Cable.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe conductor will be Class B compressed concentric stranded bare copper in accordance with ASTM B3 and B8 and ICEA Part 2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe following standards will form part of this specification - ASTM B-8, ICEA S-66-524\/NEMA WC7, UL 44, UL 1569, UL 2225, IEEE 1202, and ICEA T-29-520.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe insulation will be XLP meeting the requirements of the referenced standards. The insulation thickness will be listed in ICEA Table 3.1, and the minimum spot thickness will not be less than 90% of the listed amounts. Individual conductors will be color coded per ICEA S-58-679, using Method 3, Table 2 for sizes AWG 4 and larger, and using Method 1, Table 2 for sizes AWG 6 and smaller.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAssembly:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003eThe insulated conductors will be cabled round with three symmetrically placed ground wires, fillers and covered with a binder tape\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eContinuous corrugated aluminum sheath shall be applied over the assembly. The continuous sheath will be impervious to moisture, liquids, \u0026amp; gasses\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable will be covered with a black PVC jacket conforming to the requirements specified for polyvinyl chloride in ICEA. The average thickness will be in accordance with ICEA, and the minimum spot thickness will not be less than 80% of the average thickness. The jacket will be sunlight and oil resistant and will meet the requirements of the IEEE 1202 (70,000 Btu\/hr) and ICEA T-29-520 (210,000 Btu\/hr) vertical cable tray flame tests. The jacket will be suitable for use at a minimum ambient temperature of -40°C.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIdentification:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eManufacturer's identification will be printed on the jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Number of  Conductors:\u003c\/strong\u003e\u003cspan\u003e 4\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 0.193\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (In):\u003c\/strong\u003e 0.055\u003cbr\u003e\u003cstrong\u003e• Approx. Core Diameter (In):\u003c\/strong\u003e 1.082 \u003cbr\u003e\u003cstrong\u003e• Grounds No. x AWG:\u003c\/strong\u003e 1 x 6 \u003cbr\u003e\u003cstrong\u003e• Armored Diameter (In):\u003c\/strong\u003e 1.43 \u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (In):\u003c\/strong\u003e 0.060\u003cbr\u003e\u003cstrong\u003e• Approx. Overall Diameter (In):\u003c\/strong\u003e 1.55\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:\u003c\/strong\u003e 120\u003cbr\u003e\u003cstrong\u003e• Approx Net Weight lbs.\/Mft.:\u003c\/strong\u003e 1642\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":51648575701361,"sku":"NNC070157","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_732068f9-0638-4b12-a290-acc004801b1d.png?v=1759829526"},{"product_id":"1-0-awg-4c-w-g-type-mc-hl-copper-conductor-corrugated-aluminum-armored-pvc-tray-cable-600v","title":"1\/0 AWG 4C W\/G Type MC-HL Copper Conductor Corrugated Aluminum Armored PVC Tray Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/CatalogG5.pdf?v=1729671546\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1\/0 AWG 4C W\/G Type MC-HL Copper Conductor Corrugated Aluminum Armored PVC Tray Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eAllowable ampacity\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e1\/0 AWG 4C W\/G Type MC-HL Copper Conductor Corrugated Aluminum Armored PVC Tray Cable 600V\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e: 136 amps 90°C Ambient\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3 - 4 copper conductors\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eXLP insulation\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eCopper ground wire\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e• Aerial Installations \u003cbr\u003e• Open Trays\u003cbr\u003e• Direct Burial\u003cbr\u003e• Troughs or continuous rigid cable supports\u003cbr\u003e• Concrete-encased Installations\u003cbr\u003e• Type MC-HL power cable provides an impervious sheath recommended as an economical alternative to traditional conduit systems. It is approved for Classes I, II and III, Division 1 or 2, hazardous locations covered under NEC Articles 501, 502 and 503. The cable is designed with three symmetrically placed grounds to reduce problems associated with pulse-width modulated ac drives. These cables are capable of operating continuously in wet or dry locations at a maximum conductor temperature of 90°C for normal operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eScope:\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003eThis specification covers three or four conductor XLP (cross-linked polyethylene) insulated, continuous corrugated aluminum armored, thermoplastic jacketed, 600 volt cable with grounding conductor for use in aerial installations, metal racks, open trays, troughs or continuous rigid cable supports. The cable will be listed Type MC-HL for Classes I, II and III, Division 1 and 2, hazardous locations and have three symmetrically placed grounds to reduce problems associated with pulse-width modulated ac drives. This cable is capable of operation continuously at a conductor temperature of 90°C in wet or dry locations.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1\/0 AWG 4C Type MC-HL W\/G Cable, Armored Cable, Tray Cable, 1\/0 AWG 4C MC-HL W\/G Armored Cable, 600V Tray Cable, 1\/0 AWG 4C Aluminum Armored PVC Tray Cable.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe conductor will be Class B compressed concentric stranded bare copper in accordance with ASTM B3 and B8 and ICEA Part 2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe following standards will form part of this specification - ASTM B-8, ICEA S-66-524\/NEMA WC7, UL 44, UL 1569, UL 2225, IEEE 1202, and ICEA T-29-520.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe insulation will be XLP meeting the requirements of the referenced standards. The insulation thickness will be listed in ICEA Table 3.1, and the minimum spot thickness will not be less than 90% of the listed amounts. Individual conductors will be color coded per ICEA S-58-679, using Method 3, Table 2 for sizes AWG 4 and larger, and using Method 1, Table 2 for sizes AWG 6 and smaller.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAssembly:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003eThe insulated conductors will be cabled round with three symmetrically placed ground wires, fillers and covered with a binder tape\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eContinuous corrugated aluminum sheath shall be applied over the assembly. The continuous sheath will be impervious to moisture, liquids, \u0026amp; gasses\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable will be covered with a black PVC jacket conforming to the requirements specified for polyvinyl chloride in ICEA. The average thickness will be in accordance with ICEA, and the minimum spot thickness will not be less than 80% of the average thickness. The jacket will be sunlight and oil resistant and will meet the requirements of the IEEE 1202 (70,000 Btu\/hr) and ICEA T-29-520 (210,000 Btu\/hr) vertical cable tray flame tests. The jacket will be suitable for use at a minimum ambient temperature of -40°C.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIdentification:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eManufacturer's identification will be printed on the jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1\/0 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Number of  Conductors:\u003c\/strong\u003e\u003cspan\u003e 4\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 0.362 \u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (In):\u003c\/strong\u003e 0.055\u003cbr\u003e\u003cstrong\u003e• Approx. Core Diameter (In):\u003c\/strong\u003e 1.178\u003cbr\u003e\u003cstrong\u003e• Grounds No. x AWG:\u003c\/strong\u003e 1 x 6 \u003cbr\u003e\u003cstrong\u003e• Armored Diameter (In):\u003c\/strong\u003e 1.47\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (In):\u003c\/strong\u003e 0.060\u003cbr\u003e\u003cstrong\u003e• Approx. Overall Diameter (In):\u003c\/strong\u003e 1.59\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:\u003c\/strong\u003e 136\u003cbr\u003e\u003cstrong\u003e• Approx Net Weight lbs.\/Mft.:\u003c\/strong\u003e 1950\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":51648575996273,"sku":"NNC070158","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_96ec9168-6411-489f-9fb8-0431fcdb675d.png?v=1763008232"},{"product_id":"2-0-awg-4c-w-g-type-mc-hl-copper-conductor-corrugated-aluminum-armored-pvc-tray-cable-600v","title":"2\/0 AWG 4C W\/G Type MC-HL Copper Conductor Corrugated Aluminum Armored PVC Tray Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/CatalogG5.pdf?v=1729671546\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2\/0 AWG 4C W\/G Type MC-HL Copper Conductor Corrugated Aluminum Armored PVC Tray Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eAllowable ampacity\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e2\/0 AWG 4C W\/G Type MC-HL Copper Conductor Corrugated Aluminum Armored PVC Tray Cable 600V\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e: 156 amps 90°C Ambient\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3 - 4 copper conductors\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eXLP insulation\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eCopper ground wire\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e• Aerial Installations \u003cbr\u003e• Open Trays\u003cbr\u003e• Direct Burial\u003cbr\u003e• Troughs or continuous rigid cable supports\u003cbr\u003e• Concrete-encased Installations\u003cbr\u003e• Type MC-HL power cable provides an impervious sheath recommended as an economical alternative to traditional conduit systems. It is approved for Classes I, II and III, Division 1 or 2, hazardous locations covered under NEC Articles 501, 502 and 503. The cable is designed with three symmetrically placed grounds to reduce problems associated with pulse-width modulated ac drives. These cables are capable of operating continuously in wet or dry locations at a maximum conductor temperature of 90°C for normal operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eScope:\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003eThis specification covers three or four conductor XLP (cross-linked polyethylene) insulated, continuous corrugated aluminum armored, thermoplastic jacketed, 600 volt cable with grounding conductor for use in aerial installations, metal racks, open trays, troughs or continuous rigid cable supports. The cable will be listed Type MC-HL for Classes I, II and III, Division 1 and 2, hazardous locations and have three symmetrically placed grounds to reduce problems associated with pulse-width modulated ac drives. This cable is capable of operation continuously at a conductor temperature of 90°C in wet or dry locations.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e2\/0 AWG 4C Type MC-HL W\/G Cable, Armored Cable, Tray Cable, 2\/0 AWG 4C MC-HL W\/G Armored Cable, 600V Tray Cable, 2\/0 AWG 4C Aluminum Armored PVC Tray Cable.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe conductor will be Class B compressed concentric stranded bare copper in accordance with ASTM B3 and B8 and ICEA Part 2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe following standards will form part of this specification - ASTM B-8, ICEA S-66-524\/NEMA WC7, UL 44, UL 1569, UL 2225, IEEE 1202, and ICEA T-29-520.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe insulation will be XLP meeting the requirements of the referenced standards. The insulation thickness will be listed in ICEA Table 3.1, and the minimum spot thickness will not be less than 90% of the listed amounts. Individual conductors will be color coded per ICEA S-58-679, using Method 3, Table 2 for sizes AWG 4 and larger, and using Method 1, Table 2 for sizes AWG 6 and smaller.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAssembly:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003eThe insulated conductors will be cabled round with three symmetrically placed ground wires, fillers and covered with a binder tape\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eContinuous corrugated aluminum sheath shall be applied over the assembly. The continuous sheath will be impervious to moisture, liquids, \u0026amp; gasses\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable will be covered with a black PVC jacket conforming to the requirements specified for polyvinyl chloride in ICEA. The average thickness will be in accordance with ICEA, and the minimum spot thickness will not be less than 80% of the average thickness. The jacket will be sunlight and oil resistant and will meet the requirements of the IEEE 1202 (70,000 Btu\/hr) and ICEA T-29-520 (210,000 Btu\/hr) vertical cable tray flame tests. The jacket will be suitable for use at a minimum ambient temperature of -40°C.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIdentification:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eManufacturer's identification will be printed on the jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2\/0 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Number of  Conductors:\u003c\/strong\u003e\u003cspan\u003e 4\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 0.406 \u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (In):\u003c\/strong\u003e 0.055\u003cbr\u003e\u003cstrong\u003e• Approx. Core Diameter (In):\u003c\/strong\u003e 1.285 \u003cbr\u003e\u003cstrong\u003e• Grounds No. x AWG:\u003c\/strong\u003e 1 x 4 \u003cbr\u003e\u003cstrong\u003e• Armored Diameter (In):\u003c\/strong\u003e 1.59 \u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (In):\u003c\/strong\u003e 0.070 \u003cbr\u003e\u003cstrong\u003e• Approx. Overall Diameter (In):\u003c\/strong\u003e 1.73 \u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:\u003c\/strong\u003e 156\u003cbr\u003e\u003cstrong\u003e• Approx Net Weight lbs.\/Mft.:\u003c\/strong\u003e 2420 \u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":51648576422257,"sku":"NNC070159","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_6331b8a9-6352-4598-8ef3-51b54ab2c74e.png?v=1763008234"},{"product_id":"4-0-awg-4c-w-g-type-mc-hl-copper-conductor-corrugated-aluminum-armored-pvc-tray-cable-600v","title":"4\/0 AWG 4C W\/G Type MC-HL Copper Conductor Corrugated Aluminum Armored PVC Tray Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/CatalogG5.pdf?v=1729671546\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e4\/0 AWG 4C W\/G Type MC-HL Copper Conductor Corrugated Aluminum Armored PVC Tray Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eAllowable ampacity\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e4\/0 AWG 4C W\/G Type MC-HL Copper Conductor Corrugated Aluminum Armored PVC Tray Cable 600V\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e: 208 amps 90°C Ambient\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3 - 4 copper conductors\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eXLP insulation\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eCopper ground wire\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e• Aerial Installations \u003cbr\u003e• Open Trays\u003cbr\u003e• Direct Burial\u003cbr\u003e• Troughs or continuous rigid cable supports\u003cbr\u003e• Concrete-encased Installations\u003cbr\u003e• Type MC-HL power cable provides an impervious sheath recommended as an economical alternative to traditional conduit systems. It is approved for Classes I, II and III, Division 1 or 2, hazardous locations covered under NEC Articles 501, 502 and 503. The cable is designed with three symmetrically placed grounds to reduce problems associated with pulse-width modulated ac drives. These cables are capable of operating continuously in wet or dry locations at a maximum conductor temperature of 90°C for normal operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eScope:\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003eThis specification covers three or four conductor XLP (cross-linked polyethylene) insulated, continuous corrugated aluminum armored, thermoplastic jacketed, 600 volt cable with grounding conductor for use in aerial installations, metal racks, open trays, troughs or continuous rigid cable supports. The cable will be listed Type MC-HL for Classes I, II and III, Division 1 and 2, hazardous locations and have three symmetrically placed grounds to reduce problems associated with pulse-width modulated ac drives. This cable is capable of operation continuously at a conductor temperature of 90°C in wet or dry locations.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e4\/0 AWG 4C Type MC-HL W\/G Cable, Armored Cable, Tray Cable, 4\/0 AWG 4C MC-HL W\/G Armored Cable, 600V Tray Cable, 4\/0 AWG 4C Aluminum Armored PVC Tray Cable.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe conductor will be Class B compressed concentric stranded bare copper in accordance with ASTM B3 and B8 and ICEA Part 2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe following standards will form part of this specification - ASTM B-8, ICEA S-66-524\/NEMA WC7, UL 44, UL 1569, UL 2225, IEEE 1202, and ICEA T-29-520.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe insulation will be XLP meeting the requirements of the referenced standards. The insulation thickness will be listed in ICEA Table 3.1, and the minimum spot thickness will not be less than 90% of the listed amounts. Individual conductors will be color coded per ICEA S-58-679, using Method 3, Table 2 for sizes AWG 4 and larger, and using Method 1, Table 2 for sizes AWG 6 and smaller.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAssembly:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003eThe insulated conductors will be cabled round with three symmetrically placed ground wires, fillers and covered with a binder tape\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eContinuous corrugated aluminum sheath shall be applied over the assembly. The continuous sheath will be impervious to moisture, liquids, \u0026amp; gasses\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable will be covered with a black PVC jacket conforming to the requirements specified for polyvinyl chloride in ICEA. The average thickness will be in accordance with ICEA, and the minimum spot thickness will not be less than 80% of the average thickness. The jacket will be sunlight and oil resistant and will meet the requirements of the IEEE 1202 (70,000 Btu\/hr) and ICEA T-29-520 (210,000 Btu\/hr) vertical cable tray flame tests. The jacket will be suitable for use at a minimum ambient temperature of -40°C.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIdentification:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eManufacturer's identification will be printed on the jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 4\/0 AWG\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Number of  Conductors:\u003c\/strong\u003e\u003cspan\u003e 4\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 0.512 \u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (In):\u003c\/strong\u003e 0.055\u003cbr\u003e\u003cstrong\u003e• Approx. Core Diameter (In):\u003c\/strong\u003e 1.540 \u003cbr\u003e\u003cstrong\u003e• Grounds No. x AWG:\u003c\/strong\u003e 1 x 4 \u003cbr\u003e\u003cstrong\u003e• Armored Diameter (In):\u003c\/strong\u003e 1.87 \u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (In):\u003c\/strong\u003e 0.070 \u003cbr\u003e\u003cstrong\u003e• Approx. Overall Diameter (In):\u003c\/strong\u003e 2.01\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:\u003c\/strong\u003e 208\u003cbr\u003e\u003cstrong\u003e• Approx Net Weight lbs.\/Mft.:\u003c\/strong\u003e 3548\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":51648577536369,"sku":"NNC070160","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_83d5f1f7-ac1b-4586-b970-b4433e324c75.png?v=1763008235"},{"product_id":"250-mcm-4c-w-g-type-mc-hl-copper-conductor-corrugated-aluminum-armored-pvc-tray-cable-600v","title":"250 MCM 4C W\/G Type MC-HL Copper Conductor Corrugated Aluminum Armored PVC Tray Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/CatalogG5.pdf?v=1729671546\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e250 MCM 4C W\/G Type MC-HL Copper Conductor Corrugated Aluminum Armored PVC Tray Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eAllowable ampacity\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e250 MCM 4C W\/G Type MC-HL Copper Conductor Corrugated Aluminum Armored PVC Tray Cable 600V\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e: 232 amps 90°C Ambient\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3 - 4 copper conductors\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eXLP insulation\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eCopper ground wire\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e• Aerial Installations \u003cbr\u003e• Open Trays\u003cbr\u003e• Direct Burial\u003cbr\u003e• Troughs or continuous rigid cable supports\u003cbr\u003e• Concrete-encased Installations\u003cbr\u003e• Type MC-HL power cable provides an impervious sheath recommended as an economical alternative to traditional conduit systems. It is approved for Classes I, II and III, Division 1 or 2, hazardous locations covered under NEC Articles 501, 502 and 503. The cable is designed with three symmetrically placed grounds to reduce problems associated with pulse-width modulated ac drives. These cables are capable of operating continuously in wet or dry locations at a maximum conductor temperature of 90°C for normal operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eScope:\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003eThis specification covers three or four conductor XLP (cross-linked polyethylene) insulated, continuous corrugated aluminum armored, thermoplastic jacketed, 600 volt cable with grounding conductor for use in aerial installations, metal racks, open trays, troughs or continuous rigid cable supports. The cable will be listed Type MC-HL for Classes I, II and III, Division 1 and 2, hazardous locations and have three symmetrically placed grounds to reduce problems associated with pulse-width modulated ac drives. This cable is capable of operation continuously at a conductor temperature of 90°C in wet or dry locations.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e250 MCMv 4C Type MC-HL W\/G Cable, Armored Cable, Tray Cable, 250 MCM 4C MC-HL W\/G Armored Cable, 600V Tray Cable, 250 MCM 4C Aluminum Armored PVC Tray Cable.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe conductor will be Class B compressed concentric stranded bare copper in accordance with ASTM B3 and B8 and ICEA Part 2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe following standards will form part of this specification - ASTM B-8, ICEA S-66-524\/NEMA WC7, UL 44, UL 1569, UL 2225, IEEE 1202, and ICEA T-29-520.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe insulation will be XLP meeting the requirements of the referenced standards. The insulation thickness will be listed in ICEA Table 3.1, and the minimum spot thickness will not be less than 90% of the listed amounts. Individual conductors will be color coded per ICEA S-58-679, using Method 3, Table 2 for sizes AWG 4 and larger, and using Method 1, Table 2 for sizes AWG 6 and smaller.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAssembly:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003eThe insulated conductors will be cabled round with three symmetrically placed ground wires, fillers and covered with a binder tape\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eContinuous corrugated aluminum sheath shall be applied over the assembly. The continuous sheath will be impervious to moisture, liquids, \u0026amp; gasses\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable will be covered with a black PVC jacket conforming to the requirements specified for polyvinyl chloride in ICEA. The average thickness will be in accordance with ICEA, and the minimum spot thickness will not be less than 80% of the average thickness. The jacket will be sunlight and oil resistant and will meet the requirements of the IEEE 1202 (70,000 Btu\/hr) and ICEA T-29-520 (210,000 Btu\/hr) vertical cable tray flame tests. The jacket will be suitable for use at a minimum ambient temperature of -40°C.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIdentification:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eManufacturer's identification will be printed on the jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 250 MCM\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Number of  Conductors:\u003c\/strong\u003e\u003cspan\u003e 4\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 0.558\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (In):\u003c\/strong\u003e 0.065 \u003cbr\u003e\u003cstrong\u003e• Approx. Core Diameter (In):\u003c\/strong\u003e 1.700\u003cbr\u003e\u003cstrong\u003e• Grounds No. x AWG:\u003c\/strong\u003e 1 x 4 \u003cbr\u003e\u003cstrong\u003e• Armored Diameter (In):\u003c\/strong\u003e 2.04 \u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (In):\u003c\/strong\u003e 0.070 \u003cbr\u003e\u003cstrong\u003e• Approx. Overall Diameter (In):\u003c\/strong\u003e 2.18\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:\u003c\/strong\u003e 232\u003cbr\u003e\u003cstrong\u003e• Approx Net Weight lbs.\/Mft.:\u003c\/strong\u003e 4116\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":51648577634673,"sku":"NNC070161","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_44880049-b870-459a-bfee-e500a44d3f12.png?v=1763008235"},{"product_id":"350-mcm-4c-w-g-type-mc-hl-copper-conductor-corrugated-aluminum-armored-pvc-tray-cable-600v","title":"350 MCM 4C W\/G Type MC-HL Copper Conductor Corrugated Aluminum Armored PVC Tray Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/CatalogG5.pdf?v=1729671546\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e350 MCM 4C W\/G Type MC-HL Copper Conductor Corrugated Aluminum Armored PVC Tray Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eAllowable ampacity\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e350 MCM 4C W\/G Type MC-HL Copper Conductor Corrugated Aluminum Armored PVC Tray Cable 600V\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e: 232 amps 90°C Ambient\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3 - 4 copper conductors\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eXLP insulation\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eCopper ground wire\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e• Aerial Installations \u003cbr\u003e• Open Trays\u003cbr\u003e• Direct Burial\u003cbr\u003e• Troughs or continuous rigid cable supports\u003cbr\u003e• Concrete-encased Installations\u003cbr\u003e• Type MC-HL power cable provides an impervious sheath recommended as an economical alternative to traditional conduit systems. It is approved for Classes I, II and III, Division 1 or 2, hazardous locations covered under NEC Articles 501, 502 and 503. The cable is designed with three symmetrically placed grounds to reduce problems associated with pulse-width modulated ac drives. These cables are capable of operating continuously in wet or dry locations at a maximum conductor temperature of 90°C for normal operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eScope:\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003eThis specification covers three or four conductor XLP (cross-linked polyethylene) insulated, continuous corrugated aluminum armored, thermoplastic jacketed, 600 volt cable with grounding conductor for use in aerial installations, metal racks, open trays, troughs or continuous rigid cable supports. The cable will be listed Type MC-HL for Classes I, II and III, Division 1 and 2, hazardous locations and have three symmetrically placed grounds to reduce problems associated with pulse-width modulated ac drives. This cable is capable of operation continuously at a conductor temperature of 90°C in wet or dry locations.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e350 MCM 4C Type MC-HL W\/G Cable, Armored Cable, Tray Cable, 350 MCM 4C MC-HL W\/G Armored Cable, 600V Tray Cable, 350 MCM 4C Aluminum Armored PVC Tray Cable.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe conductor will be Class B compressed concentric stranded bare copper in accordance with ASTM B3 and B8 and ICEA Part 2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe following standards will form part of this specification - ASTM B-8, ICEA S-66-524\/NEMA WC7, UL 44, UL 1569, UL 2225, IEEE 1202, and ICEA T-29-520.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe insulation will be XLP meeting the requirements of the referenced standards. The insulation thickness will be listed in ICEA Table 3.1, and the minimum spot thickness will not be less than 90% of the listed amounts. Individual conductors will be color coded per ICEA S-58-679, using Method 3, Table 2 for sizes AWG 4 and larger, and using Method 1, Table 2 for sizes AWG 6 and smaller.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAssembly:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003eThe insulated conductors will be cabled round with three symmetrically placed ground wires, fillers and covered with a binder tape\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eContinuous corrugated aluminum sheath shall be applied over the assembly. The continuous sheath will be impervious to moisture, liquids, \u0026amp; gasses\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable will be covered with a black PVC jacket conforming to the requirements specified for polyvinyl chloride in ICEA. The average thickness will be in accordance with ICEA, and the minimum spot thickness will not be less than 80% of the average thickness. The jacket will be sunlight and oil resistant and will meet the requirements of the IEEE 1202 (70,000 Btu\/hr) and ICEA T-29-520 (210,000 Btu\/hr) vertical cable tray flame tests. The jacket will be suitable for use at a minimum ambient temperature of -40°C.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIdentification:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eManufacturer's identification will be printed on the jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 350 MCM\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Number of  Conductors:\u003c\/strong\u003e\u003cspan\u003e 4\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 0.660 \u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (In):\u003c\/strong\u003e 0.065 \u003cbr\u003e\u003cstrong\u003e• Approx. Core Diameter (In):\u003c\/strong\u003e 1.947\u003cbr\u003e\u003cstrong\u003e• Grounds No. x AWG:\u003c\/strong\u003e 1 x 3\u003cbr\u003e\u003cstrong\u003e• Armored Diameter (In):\u003c\/strong\u003e 2.29 \u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (In):\u003c\/strong\u003e 0.085\u003cbr\u003e\u003cstrong\u003e• Approx. Overall Diameter (In):\u003c\/strong\u003e 2.46\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:\u003c\/strong\u003e 280\u003cbr\u003e\u003cstrong\u003e• Approx Net Weight lbs.\/Mft.:\u003c\/strong\u003e 5633\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":51648578093425,"sku":"NNC070162","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_ede2a4a6-ce2e-43a6-8da6-5875e399e396.png?v=1759829527"},{"product_id":"500-mcm-4c-w-g-type-mc-hl-copper-conductor-corrugated-aluminum-armored-pvc-tray-cable-600v","title":"500 MCM 4C W\/G Type MC-HL Copper Conductor Corrugated Aluminum Armored PVC Tray Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/CatalogG5.pdf?v=1729671546\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e500 MCM 4C W\/G Type MC-HL Copper Conductor Corrugated Aluminum Armored PVC Tray Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eAllowable ampacity\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e500 MCM 4C W\/G Type MC-HL Copper Conductor Corrugated Aluminum Armored PVC Tray Cable 600V\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e: 232 amps 90°C Ambient\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3 - 4 copper conductors\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eXLP insulation\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eCopper ground wire\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e• Aerial Installations \u003cbr\u003e• Open Trays\u003cbr\u003e• Direct Burial\u003cbr\u003e• Troughs or continuous rigid cable supports\u003cbr\u003e• Concrete-encased Installations\u003cbr\u003e• Type MC-HL power cable provides an impervious sheath recommended as an economical alternative to traditional conduit systems. It is approved for Classes I, II and III, Division 1 or 2, hazardous locations covered under NEC Articles 501, 502 and 503. The cable is designed with three symmetrically placed grounds to reduce problems associated with pulse-width modulated ac drives. These cables are capable of operating continuously in wet or dry locations at a maximum conductor temperature of 90°C for normal operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eScope:\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003eThis specification covers three or four conductor XLP (cross-linked polyethylene) insulated, continuous corrugated aluminum armored, thermoplastic jacketed, 600 volt cable with grounding conductor for use in aerial installations, metal racks, open trays, troughs or continuous rigid cable supports. The cable will be listed Type MC-HL for Classes I, II and III, Division 1 and 2, hazardous locations and have three symmetrically placed grounds to reduce problems associated with pulse-width modulated ac drives. This cable is capable of operation continuously at a conductor temperature of 90°C in wet or dry locations.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e500 MCM 4C Type MC-HL W\/G Cable, Armored Cable, Tray Cable, 500 MCM 4C MC-HL W\/G Armored Cable, 600V Tray Cable, 500 MCM 4C Aluminum Armored PVC Tray Cable.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe conductor will be Class B compressed concentric stranded bare copper in accordance with ASTM B3 and B8 and ICEA Part 2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe following standards will form part of this specification - ASTM B-8, ICEA S-66-524\/NEMA WC7, UL 44, UL 1569, UL 2225, IEEE 1202, and ICEA T-29-520.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe insulation will be XLP meeting the requirements of the referenced standards. The insulation thickness will be listed in ICEA Table 3.1, and the minimum spot thickness will not be less than 90% of the listed amounts. Individual conductors will be color coded per ICEA S-58-679, using Method 3, Table 2 for sizes AWG 4 and larger, and using Method 1, Table 2 for sizes AWG 6 and smaller.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAssembly:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003eThe insulated conductors will be cabled round with three symmetrically placed ground wires, fillers and covered with a binder tape\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eContinuous corrugated aluminum sheath shall be applied over the assembly. The continuous sheath will be impervious to moisture, liquids, \u0026amp; gasses\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable will be covered with a black PVC jacket conforming to the requirements specified for polyvinyl chloride in ICEA. The average thickness will be in accordance with ICEA, and the minimum spot thickness will not be less than 80% of the average thickness. The jacket will be sunlight and oil resistant and will meet the requirements of the IEEE 1202 (70,000 Btu\/hr) and ICEA T-29-520 (210,000 Btu\/hr) vertical cable tray flame tests. The jacket will be suitable for use at a minimum ambient temperature of -40°C.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIdentification:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eManufacturer's identification will be printed on the jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 500 MCM\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Number of  Conductors:\u003c\/strong\u003e\u003cspan\u003e 4\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 0.789\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (In):\u003c\/strong\u003e 0.065 \u003cbr\u003e\u003cstrong\u003e• Approx. Core Diameter (In):\u003c\/strong\u003e 2.258 \u003cbr\u003e\u003cstrong\u003e• Grounds No. x AWG:\u003c\/strong\u003e 1 x 2 \u003cbr\u003e\u003cstrong\u003e• Armored Diameter (In):\u003c\/strong\u003e 2.67\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (In):\u003c\/strong\u003e 0.085\u003cbr\u003e\u003cstrong\u003e• Approx. Overall Diameter (In):\u003c\/strong\u003e 2.84\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:\u003c\/strong\u003e 344\u003cbr\u003e\u003cstrong\u003e• Approx Net Weight lbs.\/Mft.:\u003c\/strong\u003e 7891 \u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":51648583663985,"sku":"NNC070163","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_f1f4a016-981c-43f2-8b0e-1190cb6b5e50.png?v=1763008238"},{"product_id":"750-mcm-4c-w-g-type-mc-hl-copper-conductor-corrugated-aluminum-armored-pvc-tray-cable-600v","title":"750 MCM 4C W\/G Type MC-HL Copper Conductor Corrugated Aluminum Armored PVC Tray Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/CatalogG5.pdf?v=1729671546\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e750 MCM 4C W\/G Type MC-HL Copper Conductor Corrugated Aluminum Armored PVC Tray Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eAllowable ampacity\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-sheets-root=\"1\"\u003e750 MCM 4C W\/G Type MC-HL Copper Conductor Corrugated Aluminum Armored PVC Tray Cable 600V\u003c\/span\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e: 232 amps 90°C Ambient\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3 - 4 copper conductors\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eXLP insulation\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eCopper ground wire\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e• Aerial Installations \u003cbr\u003e• Open Trays\u003cbr\u003e• Direct Burial\u003cbr\u003e• Troughs or continuous rigid cable supports\u003cbr\u003e• Concrete-encased Installations\u003cbr\u003e• Type MC-HL power cable provides an impervious sheath recommended as an economical alternative to traditional conduit systems. It is approved for Classes I, II and III, Division 1 or 2, hazardous locations covered under NEC Articles 501, 502 and 503. The cable is designed with three symmetrically placed grounds to reduce problems associated with pulse-width modulated ac drives. These cables are capable of operating continuously in wet or dry locations at a maximum conductor temperature of 90°C for normal operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eScope:\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003eThis specification covers three or four conductor XLP (cross-linked polyethylene) insulated, continuous corrugated aluminum armored, thermoplastic jacketed, 600 volt cable with grounding conductor for use in aerial installations, metal racks, open trays, troughs or continuous rigid cable supports. The cable will be listed Type MC-HL for Classes I, II and III, Division 1 and 2, hazardous locations and have three symmetrically placed grounds to reduce problems associated with pulse-width modulated ac drives. This cable is capable of operation continuously at a conductor temperature of 90°C in wet or dry locations.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e750 MCM 4C Type MC-HL W\/G Cable, Armored Cable, Tray Cable, 750 MCM 4C MC-HL W\/G Armored Cable, 600V Tray Cable, 750 MCM 4C Aluminum Armored PVC Tray Cable.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe conductor will be Class B compressed concentric stranded bare copper in accordance with ASTM B3 and B8 and ICEA Part 2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe following standards will form part of this specification - ASTM B-8, ICEA S-66-524\/NEMA WC7, UL 44, UL 1569, UL 2225, IEEE 1202, and ICEA T-29-520.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe insulation will be XLP meeting the requirements of the referenced standards. The insulation thickness will be listed in ICEA Table 3.1, and the minimum spot thickness will not be less than 90% of the listed amounts. Individual conductors will be color coded per ICEA S-58-679, using Method 3, Table 2 for sizes AWG 4 and larger, and using Method 1, Table 2 for sizes AWG 6 and smaller.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAssembly:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003eThe insulated conductors will be cabled round with three symmetrically placed ground wires, fillers and covered with a binder tape\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eContinuous corrugated aluminum sheath shall be applied over the assembly. The continuous sheath will be impervious to moisture, liquids, \u0026amp; gasses\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable will be covered with a black PVC jacket conforming to the requirements specified for polyvinyl chloride in ICEA. The average thickness will be in accordance with ICEA, and the minimum spot thickness will not be less than 80% of the average thickness. The jacket will be sunlight and oil resistant and will meet the requirements of the IEEE 1202 (70,000 Btu\/hr) and ICEA T-29-520 (210,000 Btu\/hr) vertical cable tray flame tests. The jacket will be suitable for use at a minimum ambient temperature of -40°C.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIdentification:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eManufacturer's identification will be printed on the jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 750 MCM\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Number of  Conductors:\u003c\/strong\u003e\u003cspan\u003e 4\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 0.968\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (In):\u003c\/strong\u003e 0.080 \u003cbr\u003e\u003cstrong\u003e• Approx. Core Diameter (In):\u003c\/strong\u003e 2.762 \u003cbr\u003e\u003cstrong\u003e• Grounds No. x AWG:\u003c\/strong\u003e 1 x 1 \u003cbr\u003e\u003cstrong\u003e• Armored Diameter (In):\u003c\/strong\u003e 3.22\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (In):\u003c\/strong\u003e 0.095\u003cbr\u003e\u003cstrong\u003e• Approx. Overall Diameter (In):\u003c\/strong\u003e 3.41\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C:\u003c\/strong\u003e 428\u003cbr\u003e\u003cstrong\u003e• Approx Net Weight lbs.\/Mft.:\u003c\/strong\u003e 11530 \u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":51648584188273,"sku":"NNC070164","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3_42b78395-3bc4-4713-b918-f30b854594e6.png?v=1763008238"},{"product_id":"3-0-awg-4c-w-g-type-mc-hl-copper-conductor-corrugated-aluminum-armored-pvc-tray-cable-600v","title":"3\/0 AWG 4C W\/G Type MC-HL Copper Conductor Corrugated Aluminum Armored PVC Tray Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC45352_2.pdf?v=1750228781\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e3\/0 AWG 4C W\/G Type MC-HL Copper Conductor Corrugated Aluminum Armored PVC Tray Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSouthwire’s 600 Volt Type MC-HL ARMOR-X power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, 250°C for short circuit conditions, and -50°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e3\/0 AWG 4C W\/G MC-HL cable, Type MC-HL 600V power cable, 3\/0 AWG Copper conductor MC-HL tray cable, Aluminum armored MC-HL cable, 3\/0 AWG PVC jacketed MC-HL cable, VFD rated MC-HL cable, 3\/0 AWG UL 2225 MC-HL cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• \u003c\/strong\u003eASTM B3 Soft or Annealed Copper Wire\u003cstrong\u003e\u003cbr\u003e• \u003c\/strong\u003eASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cstrong\u003e\u003cbr\u003e• \u003c\/strong\u003eUL 44 Thermoset-Insulated Wires and Cables\u003cstrong\u003e\u003cbr\u003e• \u003c\/strong\u003eUL 1569 Metal-Clad Cables\u003cstrong\u003e\u003cbr\u003e• \u003c\/strong\u003eUL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cstrong\u003e\u003cbr\u003e• \u003c\/strong\u003eICEA S-58-679 Control Cable Conductor Identification Method 3 (1-BLACK, 2-RED, 3-BLUE)\u003cstrong\u003e\u003cbr\u003e• \u003c\/strong\u003eICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cstrong\u003e\u003cbr\u003e• \u003c\/strong\u003eIEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and B8\u003cstrong\u003e\u003cbr\u003e• Insulation: \u003c\/strong\u003eCross Linked Polyethylene (XLPE) Type XHHW-2\u003cstrong\u003e\u003cbr\u003e•  Grounding Conductor: \u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and B8\u003cstrong\u003e\u003cbr\u003e•  Filler: \u003c\/strong\u003ePolypropylene filler\u003cstrong\u003e\u003cbr\u003e•  Binder: \u003c\/strong\u003ePolypropylene tape\u003cstrong\u003e\u003cbr\u003e•  Armor: \u003c\/strong\u003eARMOR-X Continuous Corrugated Welded Armor\u003cstrong\u003e\u003cbr\u003e•  Overall Jacket:\u003c\/strong\u003e Polyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 3\/0 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Conductor:\u003c\/strong\u003e 4\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e 0.456\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e 55\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Ground No. x AWG:\u003c\/strong\u003e 1 x 4\u003cbr\u003e\u003cstrong\u003e• Diameter Over Armor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e  1.760\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 60\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e 1.886\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e  2954\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e 13.2\u003cbr\u003e\u003cstrong\u003e• Max Pull Tension lb:\u003c\/strong\u003e  4295\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e  160\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 90°C (Amp):\u003c\/strong\u003e  180\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 53.4305%;\" height=\"35\" width=\"446\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100%;\"\u003e            \u003cstrong\u003e Compatiable with manufacturer\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable style=\"width: 54.1429%;\" height=\"32\" width=\"189\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50.245%;\"\u003e\u003cstrong\u003e      Southwire \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.2401%;\"\u003e        \u003cspan data-sheets-root=\"1\"\u003e582265\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55290615791985,"sku":"NNC582265","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/8-Photoroom.png?v=1763025870"}],"url":"https:\/\/nassaunationalcable.com\/collections\/type-mc-hl-w-g-copper-conductor-corrugated-aluminum-armored-pvc-tray-cable-600v.oembed","provider":"NassauNationalCable","version":"1.0","type":"link"}