{"title":"Three Conductor Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV - 35 kV","description":"","products":[{"product_id":"6-awg-3c-aluminum-mv-90-tape-shielded-xlpe-insulated-pvc-jacket-5-kv","title":"6 AWG 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-04-mv90-3c-xlpe-pvc_2_1.pdf?v=1756206451\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e6 AWG 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried where permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e6 AWG 3C MV-90 Cable, 3 Conductor Aluminum, Tape Shielded Cable, 6 AWG 3C XLPE Insulation, PVC Jacket, 5kV-35kV Cable, High Voltage Cable, 6 AWG 3C Aluminum MV-90, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use, 1\/0 AWG and larger.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Oil Resistance I jacket.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawnAluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset crosslinked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape, 5 mil thick, 25% minimum overlap\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or covered conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e  Black sunlight resistance and flame retardant polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 6 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 7 \u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.17\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG:\u003c\/strong\u003e 6\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 80\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 1.23\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Aluminum lb\/kft:\u003c\/strong\u003e 734\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52058536673649,"sku":"NNC06MV-90","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1234_18ad09b0-e4b9-44fc-baca-7d052eb6f363.jpg?v=1756205549"},{"product_id":"4-awg-3c-aluminum-mv-90-tape-shielded-xlpe-insulated-pvc-jacket-5-kv","title":"4 AWG 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-04-mv90-3c-xlpe-pvc_2_1.pdf?v=1756206451\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e4 AWG 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried where permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e4 AWG 3C MV-90 Cable, 3 Conductor Aluminum, Tape Shielded Cable, 4 AWG 3C XLPE Insulation, PVC Jacket, 5kV-35kV Cable, High Voltage Cable, 4 AWG 3C Aluminum MV-90, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use, 1\/0 AWG and larger.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Oil Resistance I jacket.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawnAluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset crosslinked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape, 5 mil thick, 25% minimum overlap\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or covered conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e  Black sunlight resistance and flame retardant polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 4 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 7 \u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.21\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG:\u003c\/strong\u003e 4\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 80\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 1.32\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Aluminum lb\/kft:\u003c\/strong\u003e 849\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52058537656689,"sku":"NNC04MV-90","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1234_18ad09b0-e4b9-44fc-baca-7d052eb6f363.jpg?v=1756205549"},{"product_id":"2-awg-3c-aluminum-mv-90-tape-shielded-xlpe-insulated-pvc-jacket-5-kv","title":"2 AWG 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-04-mv90-3c-xlpe-pvc_2_1.pdf?v=1756206451\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2 AWG 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried where permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e2 AWG 3C MV-90 Cable, 3 Conductor Aluminum, Tape Shielded Cable, 2 AWG 3C XLPE Insulation, PVC Jacket, 5kV-35kV Cable, High Voltage Cable, 2 AWG 3C Aluminum MV-90, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use, 1\/0 AWG and larger.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Oil Resistance I jacket.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawnAluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset crosslinked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape, 5 mil thick, 25% minimum overlap\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or covered conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e  Black sunlight resistance and flame retardant polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 7 \u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.27\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG:\u003c\/strong\u003e 4\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 80\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 1.44\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Aluminum lb\/kft:\u003c\/strong\u003e 1010\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52058552664433,"sku":"NNC02MV-90","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1234_18ad09b0-e4b9-44fc-baca-7d052eb6f363.jpg?v=1756205549"},{"product_id":"1-awg-3c-aluminum-mv-90-tape-shielded-xlpe-insulated-pvc-jacket-5-kv","title":"1 AWG 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-04-mv90-3c-xlpe-pvc_2_1.pdf?v=1756206451\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1 AWG 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried where permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e1 AWG 3C MV-90 Cable, 3 Conductor Aluminum, Tape Shielded Cable, 1 AWG 3C XLPE Insulation, PVC Jacket, 5kV-35kV Cable, High Voltage Cable, 1 AWG 3C Aluminum MV-90, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use, 1\/0 AWG and larger.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Oil Resistance I jacket.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawnAluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset crosslinked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape, 5 mil thick, 25% minimum overlap\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or covered conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e  Black sunlight resistance and flame retardant polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.30\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG:\u003c\/strong\u003e 4\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 80\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 1.51\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Aluminum lb\/kft:\u003c\/strong\u003e 1149\u003c\/span\u003e\u003c\/p\u003e","brand":"Aluminum MV-90 Cable","offers":[{"title":"Default Title","offer_id":52058560070001,"sku":"NNC01MV-90","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1234_18ad09b0-e4b9-44fc-baca-7d052eb6f363.jpg?v=1756205549"},{"product_id":"1-0-awg-3c-aluminum-mv-90-tape-shielded-xlpe-insulated-pvc-jacket-5-kv","title":"1\/0 AWG 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-04-mv90-3c-xlpe-pvc_2_1.pdf?v=1756206451\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1\/0 AWG 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried where permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e1\/0 AWG 3C MV-90 Cable, 3 Conductor Aluminum, Tape Shielded Cable, 1\/0 AWG 3C XLPE Insulation, PVC Jacket, 5kV-35kV Cable, High Voltage Cable, 1\/0 AWG 3C Aluminum MV-90, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use, 1\/0 AWG and larger.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Oil Resistance I jacket.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawnAluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset crosslinked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape, 5 mil thick, 25% minimum overlap\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or covered conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e  Black sunlight resistance and flame retardant polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1\/0 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.34\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG:\u003c\/strong\u003e 4\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 80\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 1.59\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 1273\u003c\/span\u003e\u003c\/p\u003e","brand":"Aluminum MV-90 Cable","offers":[{"title":"Default Title","offer_id":52063872975217,"sku":"NNC00MV-90","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1234_18ad09b0-e4b9-44fc-baca-7d052eb6f363.jpg?v=1756205549"},{"product_id":"2-0-awg-3c-aluminum-mv-90-tape-shielded-xlpe-insulated-pvc-jacket-5-kv","title":"2\/0 AWG 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-04-mv90-3c-xlpe-pvc_2_1.pdf?v=1756206451\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2\/0 AWG 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried where permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e2\/0 AWG 3C MV-90 Cable, 3 Conductor Aluminum, Tape Shielded Cable, 2\/0 AWG 3C XLPE Insulation, PVC Jacket, 5kV-35kV Cable, High Voltage Cable, 2\/0 AWG 3C Aluminum MV-90, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use, 1\/0 AWG and larger.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Oil Resistance I jacket.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawnAluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset crosslinked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape, 5 mil thick, 25% minimum overlap\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or covered conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e  Black sunlight resistance and flame retardant polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2\/0 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.38\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG:\u003c\/strong\u003e 2 \u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110 \u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 1.74 \u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 1559\u003c\/span\u003e\u003c\/p\u003e","brand":"Aluminum MV-90 Cable","offers":[{"title":"Default Title","offer_id":52063875039601,"sku":"NNC11MV-90","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1234_18ad09b0-e4b9-44fc-baca-7d052eb6f363.jpg?v=1756205549"},{"product_id":"3-0-awg-3c-aluminum-mv-90-tape-shielded-xlpe-insulated-pvc-jacket-5-kv","title":"3\/0 AWG 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-04-mv90-3c-xlpe-pvc_2_1.pdf?v=1756206451\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e3\/0 AWG 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried where permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e3\/0 AWG 3C MV-90 Cable, 3 Conductor Aluminum, Tape Shielded Cable, 3\/0 AWG 3C XLPE Insulation, PVC Jacket, 5kV-35kV Cable, High Voltage Cable, 3\/0 AWG 3C Aluminum MV-90, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use, 1\/0 AWG and larger.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Oil Resistance I jacket.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawnAluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset crosslinked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape, 5 mil thick, 25% minimum overlap\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or covered conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e  Black sunlight resistance and flame retardant polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 3\/0 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.42 \u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG:\u003c\/strong\u003e 2 \u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110 \u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 1.84 \u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 1746\u003c\/span\u003e\u003c\/p\u003e","brand":"Aluminum MV-90 Cable","offers":[{"title":"Default Title","offer_id":52063885590897,"sku":"NNC12MV-90","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1234_18ad09b0-e4b9-44fc-baca-7d052eb6f363.jpg?v=1756205549"},{"product_id":"4-0-awg-3c-aluminum-mv-90-tape-shielded-xlpe-insulated-pvc-jacket-5-kv","title":"4\/0 AWG 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-04-mv90-3c-xlpe-pvc_2_1.pdf?v=1756206451\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e4\/0 AWG 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried where permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e4\/0 AWG 3C MV-90 Cable, 3 Conductor Aluminum, Tape Shielded Cable, 4\/0 AWG 3C XLPE Insulation, PVC Jacket, 5kV-35kV Cable, High Voltage Cable, 4\/0 AWG 3C Aluminum MV-90, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use, 1\/0 AWG and larger.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Oil Resistance I jacket.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawnAluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset crosslinked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape, 5 mil thick, 25% minimum overlap\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or covered conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e  Black sunlight resistance and flame retardant polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 4\/0 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.48 \u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG:\u003c\/strong\u003e 2 \u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110 \u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 1.95\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 1974\u003c\/span\u003e\u003c\/p\u003e","brand":"Aluminum MV-90 Cable","offers":[{"title":"Default Title","offer_id":52063888867697,"sku":"NNC13MV-90","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1234_18ad09b0-e4b9-44fc-baca-7d052eb6f363.jpg?v=1756205549"},{"product_id":"250-mcm-3c-aluminum-mv-90-tape-shielded-xlpe-insulated-pvc-jacket-5-kv","title":"250 MCM 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-04-mv90-3c-xlpe-pvc_2_1.pdf?v=1756206451\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e250 MCM 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried where permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e250 MCM 3C MV-90 Cable, 3 Conductor Aluminum, Tape Shielded Cable, 250 MCM 3C XLPE Insulation, PVC Jacket, 5kV-35kV Cable, High Voltage Cable, 250 MCM 3C Aluminum MV-90, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use, 1\/0 AWG and larger.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Oil Resistance I jacket.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawnAluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset crosslinked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape, 5 mil thick, 25% minimum overlap\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or covered conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e  Black sunlight resistance and flame retardant polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 250 MCM\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 37 \u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.52  \u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG:\u003c\/strong\u003e 2 \u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110 \u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 2.07 \u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 2191\u003c\/span\u003e\u003c\/p\u003e","brand":"Aluminum MV-90 Cable","offers":[{"title":"Default Title","offer_id":52063890768241,"sku":"NNC14MV-90","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1234_18ad09b0-e4b9-44fc-baca-7d052eb6f363.jpg?v=1756205549"},{"product_id":"300-mcm-3c-aluminum-mv-90-tape-shielded-xlpe-insulated-pvc-jacket-5-kv","title":"300 MCM 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-04-mv90-3c-xlpe-pvc_2_1.pdf?v=1756206451\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e300 MCM 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried where permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e300 MCM 3C MV-90 Cable, 3 Conductor Aluminum, Tape Shielded Cable, 300 MCM 3C XLPE Insulation, PVC Jacket, 5kV-35kV Cable, High Voltage Cable, 300 MCM 3C Aluminum MV-90, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use, 1\/0 AWG and larger.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Oil Resistance I jacket.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawnAluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset crosslinked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape, 5 mil thick, 25% minimum overlap\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or covered conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e  Black sunlight resistance and flame retardant polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 300 MCM\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 37 \u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.57 \u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG:\u003c\/strong\u003e 1 \u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110 \u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 2.18 \u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 2468\u003c\/span\u003e\u003c\/p\u003e","brand":"Aluminum MV-90 Cable","offers":[{"title":"Default Title","offer_id":52063904465265,"sku":"NNC15MV-90","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1234_18ad09b0-e4b9-44fc-baca-7d052eb6f363.jpg?v=1756205549"},{"product_id":"350-mcm-3c-aluminum-mv-90-tape-shielded-xlpe-insulated-pvc-jacket-5-kv","title":"350 MCM 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-04-mv90-3c-xlpe-pvc_2_1.pdf?v=1756206451\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e350 MCM 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried where permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e350 MCM 3C MV-90 Cable, 3 Conductor Aluminum, Tape Shielded Cable, 350 MCM 3C XLPE Insulation, PVC Jacket, 5kV-35kV Cable, High Voltage Cable, 350 MCM 3C Aluminum MV-90, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use, 1\/0 AWG and larger.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Oil Resistance I jacket.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawnAluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset crosslinked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape, 5 mil thick, 25% minimum overlap\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or covered conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e  Black sunlight resistance and flame retardant polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 350 MCM\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 37 \u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.62 \u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG:\u003c\/strong\u003e 1 \u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110 \u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 2.28\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 2707\u003c\/span\u003e\u003c\/p\u003e","brand":"Aluminum MV-90 Cable","offers":[{"title":"Default Title","offer_id":52063907283313,"sku":"NNC16MV-90","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1234_18ad09b0-e4b9-44fc-baca-7d052eb6f363.jpg?v=1756205549"},{"product_id":"400-mcm-3c-aluminum-mv-90-tape-shielded-xlpe-insulated-pvc-jacket-5-kv","title":"400 MCM 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-04-mv90-3c-xlpe-pvc_2_1.pdf?v=1756206451\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e400 MCM 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried where permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e400 MCM 3C MV-90 Cable, 3 Conductor Aluminum, Tape Shielded Cable, 400 MCM 3C XLPE Insulation, PVC Jacket, 5kV-35kV Cable, High Voltage Cable, 400 MCM 3C Aluminum MV-90, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use, 1\/0 AWG and larger.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Oil Resistance I jacket.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawnAluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset crosslinked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape, 5 mil thick, 25% minimum overlap\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or covered conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e  Black sunlight resistance and flame retardant polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 400 MCM\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 37 \u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.66\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG:\u003c\/strong\u003e 1 \u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110 \u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 2.37\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 2939\u003c\/span\u003e\u003c\/p\u003e","brand":"Aluminum MV-90 Cable","offers":[{"title":"Default Title","offer_id":52063908594033,"sku":"NNC17MV-90","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1234_18ad09b0-e4b9-44fc-baca-7d052eb6f363.jpg?v=1756205549"},{"product_id":"500-mcm-3c-aluminum-mv-90-tape-shielded-xlpe-insulated-pvc-jacket-5-kv","title":"500 MCM 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-04-mv90-3c-xlpe-pvc_2_1.pdf?v=1756206451\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e500 MCM 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried where permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e500 MCM 3C MV-90 Cable, 3 Conductor Aluminum, Tape Shielded Cable, 500 MCM 3C XLPE Insulation, PVC Jacket, 5kV-35kV Cable, High Voltage Cable, 500 MCM 3C Aluminum MV-90, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use, 1\/0 AWG and larger.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Oil Resistance I jacket.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawnAluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset crosslinked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape, 5 mil thick, 25% minimum overlap\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or covered conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e  Black sunlight resistance and flame retardant polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 500 MCM\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 37 \u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.74\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG:\u003c\/strong\u003e 1\/0 \u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110 \u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 2.59\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 3524\u003c\/span\u003e\u003c\/p\u003e","brand":"Aluminum MV-90 Cable","offers":[{"title":"Default Title","offer_id":52063909871985,"sku":"NNC18MV-90","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1234_18ad09b0-e4b9-44fc-baca-7d052eb6f363.jpg?v=1756205549"},{"product_id":"600-mcm-3c-aluminum-mv-90-tape-shielded-xlpe-insulated-pvc-jacket-5-kv","title":"600 MCM 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-04-mv90-3c-xlpe-pvc_2_1.pdf?v=1756206451\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e600 MCM 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried where permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e600 MCM 3C MV-90 Cable, 3 Conductor Aluminum, Tape Shielded Cable, 600 MCM 3C XLPE Insulation, PVC Jacket, 5kV-35kV Cable, High Voltage Cable, 600 MCM 3C Aluminum MV-90, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use, 1\/0 AWG and larger.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Oil Resistance I jacket.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawnAluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset crosslinked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape, 5 mil thick, 25% minimum overlap\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or covered conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e  Black sunlight resistance and flame retardant polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 600 MCM\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 61\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.81 \u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG:\u003c\/strong\u003e 1\/0 \u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 140 \u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 2.84 \u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 4124\u003c\/span\u003e\u003c\/p\u003e","brand":"Aluminum MV-90 Cable","offers":[{"title":"Default Title","offer_id":52063910789489,"sku":"NNC19MV-90","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1234_18ad09b0-e4b9-44fc-baca-7d052eb6f363.jpg?v=1756205549"},{"product_id":"750-mcm-3c-aluminum-mv-90-tape-shielded-xlpe-insulated-pvc-jacket-5-kv","title":"750 MCM 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-04-mv90-3c-xlpe-pvc_2_1.pdf?v=1756206451\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e750 MCM 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried where permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e750 MCM 3C MV-90 Cable, 3 Conductor Aluminum, Tape Shielded Cable, 750 MCM 3C XLPE Insulation, PVC Jacket, 5kV-35kV Cable, High Voltage Cable, 750 MCM 3C Aluminum MV-90, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use, 1\/0 AWG and larger.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Oil Resistance I jacket.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawnAluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset crosslinked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape, 5 mil thick, 25% minimum overlap\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or covered conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e  Black sunlight resistance and flame retardant polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 750 MCM\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 61\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.91 \u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG:\u003c\/strong\u003e 2\/0 \u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 140 \u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 3.05 \u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 4831\u003c\/span\u003e\u003c\/p\u003e","brand":"Aluminum MV-90 Cable","offers":[{"title":"Default Title","offer_id":52063911281009,"sku":"NNC21MV-90","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1234_18ad09b0-e4b9-44fc-baca-7d052eb6f363.jpg?v=1756205549"},{"product_id":"1000-mcm-3c-aluminum-mv-90-tape-shielded-xlpe-insulated-pvc-jacket-5-kv","title":"1000 MCM 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-04-mv90-3c-xlpe-pvc_2_1.pdf?v=1756206451\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1000 MCM 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried where permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e1000 MCM 3C MV-90 Cable, 3 Conductor Aluminum, Tape Shielded Cable, 1000 MCM 3C XLPE Insulation, PVC Jacket, 5kV-35kV Cable, High Voltage Cable, 1000 MCM 3C Aluminum MV-90, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use, 1\/0 AWG and larger.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Oil Resistance I jacket.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawnAluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset crosslinked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape, 5 mil thick, 25% minimum overlap\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or covered conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e  Black sunlight resistance and flame retardant polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1000 MCM\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 61\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 1.06\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG:\u003c\/strong\u003e 3\/0 \u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 140 \u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 3.37 \u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 5902\u003c\/span\u003e\u003c\/p\u003e","brand":"Aluminum MV-90 Cable","offers":[{"title":"Default Title","offer_id":52063911543153,"sku":"NNC22MV-90","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1234_18ad09b0-e4b9-44fc-baca-7d052eb6f363.jpg?v=1756205549"},{"product_id":"6-awg-3c-aluminum-mv-90-tape-shielded-xlpe-100-insulation-115-mil-8-kv","title":"6 AWG 3C Aluminum MV-90 Tape Shielded XLPE 100% Insulation 115 mil 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-04-mv90-3c-xlpe-pvc_2_1.pdf?v=1756206451\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e6 AWG 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried where permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e6 AWG 3C MV-90 Cable, 3 Conductor Aluminum, Tape Shielded Cable, 6 AWG 3C XLPE Insulation, PVC Jacket, 5kV-35kV Cable, High Voltage Cable, 6 AWG 3C Aluminum MV-90, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use, 1\/0 AWG and larger.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Oil Resistance I jacket.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawnAluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset crosslinked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape, 5 mil thick, 25% minimum overlap\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or covered conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e  Black sunlight resistance and flame retardant polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 6 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 7\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.17\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG:\u003c\/strong\u003e 6\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 80\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 1.34 \u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 832 \u003c\/span\u003e\u003c\/p\u003e","brand":"Aluminum MV-90 Cable","offers":[{"title":"Default Title","offer_id":52063912722801,"sku":"NNC23MV-90","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1234_18ad09b0-e4b9-44fc-baca-7d052eb6f363.jpg?v=1756205549"},{"product_id":"4-awg-3c-aluminum-mv-90-tape-shielded-xlpe-100-insulation-115-mil-8-kv","title":"4 AWG 3C Aluminum MV-90 Tape Shielded XLPE 100% Insulation 115 mil 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-04-mv90-3c-xlpe-pvc_2_1.pdf?v=1756206451\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e4 AWG 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried where permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e4 AWG 3C MV-90 Cable, 3 Conductor Aluminum, Tape Shielded Cable, 4 AWG 3C XLPE Insulation, PVC Jacket, 5kV-35kV Cable, High Voltage Cable, 4 AWG 3C Aluminum MV-90, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use, 1\/0 AWG and larger.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Oil Resistance I jacket.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawnAluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset crosslinked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape, 5 mil thick, 25% minimum overlap\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or covered conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e  Black sunlight resistance and flame retardant polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 4 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 7\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.21\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG:\u003c\/strong\u003e 4 \u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 80\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 1.43 \u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 953\u003c\/span\u003e\u003c\/p\u003e","brand":"Aluminum MV-90 Cable","offers":[{"title":"Default Title","offer_id":52063917539697,"sku":"NNC24MV-90","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1234_18ad09b0-e4b9-44fc-baca-7d052eb6f363.jpg?v=1756205549"},{"product_id":"2-awg-3c-aluminum-mv-90-tape-shielded-xlpe-100-insulation-115-mil-8-kv","title":"2 AWG 3C Aluminum MV-90 Tape Shielded XLPE 100% Insulation 115 mil 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-04-mv90-3c-xlpe-pvc_2_1.pdf?v=1756206451\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2 AWG 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried where permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e2 AWG 3C MV-90 Cable, 3 Conductor Aluminum, Tape Shielded Cable, 2 AWG 3C XLPE Insulation, PVC Jacket, 5kV-35kV Cable, High Voltage Cable, 2 AWG 3C Aluminum MV-90, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use, 1\/0 AWG and larger.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Oil Resistance I jacket.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawnAluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset crosslinked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape, 5 mil thick, 25% minimum overlap\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or covered conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e  Black sunlight resistance and flame retardant polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 7\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.27 \u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG:\u003c\/strong\u003e 4 \u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 80\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 1.55 \u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 1122 \u003c\/span\u003e\u003c\/p\u003e","brand":"Aluminum MV-90 Cable","offers":[{"title":"Default Title","offer_id":52063922192753,"sku":"NNC25MV-90","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1234_18ad09b0-e4b9-44fc-baca-7d052eb6f363.jpg?v=1756205549"},{"product_id":"1-awg-3c-aluminum-mv-90-tape-shielded-xlpe-100-insulation-115-mil-8-kv","title":"1 AWG 3C Aluminum MV-90 Tape Shielded XLPE 100% Insulation 115 mil 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-04-mv90-3c-xlpe-pvc_2_1.pdf?v=1756206451\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1 AWG 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried where permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e1 AWG 3C MV-90 Cable, 3 Conductor Aluminum, Tape Shielded Cable, 1 AWG 3C XLPE Insulation, PVC Jacket, 5kV-35kV Cable, High Voltage Cable, 1 AWG 3C Aluminum MV-90, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use, 1\/0 AWG and larger.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Oil Resistance I jacket.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawnAluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset crosslinked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape, 5 mil thick, 25% minimum overlap\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or covered conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e  Black sunlight resistance and flame retardant polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19 \u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.30  \u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG:\u003c\/strong\u003e 4 \u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 80\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 1.62 \u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 1264 \u003c\/span\u003e\u003c\/p\u003e","brand":"Aluminum MV-90 Cable","offers":[{"title":"Default Title","offer_id":52063923732849,"sku":"NNC26MV-90","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1234_18ad09b0-e4b9-44fc-baca-7d052eb6f363.jpg?v=1756205549"},{"product_id":"1-0-awg-3c-aluminum-mv-90-tape-shielded-xlpe-100-insulation-115-mil-8-kv","title":"1\/0 AWG 3C Aluminum MV-90 Tape Shielded XLPE 100% Insulation 115 mil 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-04-mv90-3c-xlpe-pvc_2_1.pdf?v=1756206451\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1\/0 AWG 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried where permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e1\/0 AWG 3C MV-90 Cable, 3 Conductor Aluminum, Tape Shielded Cable, 1\/0 AWG 3C XLPE Insulation, PVC Jacket, 5kV-35kV Cable, High Voltage Cable, 1\/0 AWG 3C Aluminum MV-90, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use, 1\/0 AWG and larger.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Oil Resistance I jacket.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawnAluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset crosslinked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape, 5 mil thick, 25% minimum overlap\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or covered conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e  Black sunlight resistance and flame retardant polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1\/0 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19 \u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.34   \u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG:\u003c\/strong\u003e 4 \u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 1.76\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 1502\u003c\/span\u003e\u003c\/p\u003e","brand":"Aluminum MV-90 Cable","offers":[{"title":"Default Title","offer_id":52063923929457,"sku":"NNC27MV-90","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1234_18ad09b0-e4b9-44fc-baca-7d052eb6f363.jpg?v=1756205549"},{"product_id":"2-0-awg-3c-aluminum-mv-90-tape-shielded-xlpe-100-insulation-115-mil-8-kv","title":"2\/0 AWG 3C Aluminum MV-90 Tape Shielded XLPE 100% Insulation 115 mil 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-04-mv90-3c-xlpe-pvc_2_1.pdf?v=1756206451\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2\/0 AWG 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried where permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e2\/0 AWG 3C MV-90 Cable, 3 Conductor Aluminum, Tape Shielded Cable, 2\/0 AWG 3C XLPE Insulation, PVC Jacket, 5kV-35kV Cable, High Voltage Cable, 2\/0 AWG 3C Aluminum MV-90, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use, 1\/0 AWG and larger.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Oil Resistance I jacket.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawnAluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset crosslinked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape, 5 mil thick, 25% minimum overlap\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or covered conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e  Black sunlight resistance and flame retardant polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2\/0 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19 \u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.38 \u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG:\u003c\/strong\u003e 2 \u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 1.85 \u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 1691 \u003c\/span\u003e\u003c\/p\u003e","brand":"Aluminum MV-90 Cable","offers":[{"title":"Default Title","offer_id":52063924519281,"sku":"NNC28MV-90","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1234_18ad09b0-e4b9-44fc-baca-7d052eb6f363.jpg?v=1756205549"},{"product_id":"3-0-awg-3c-aluminum-mv-90-tape-shielded-xlpe-100-insulation-115-mil-8-kv","title":"3\/0 AWG 3C Aluminum MV-90 Tape Shielded XLPE 100% Insulation 115 mil 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-04-mv90-3c-xlpe-pvc_2_1.pdf?v=1756206451\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e3\/0 AWG 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried where permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e3\/0 AWG 3C MV-90 Cable, 3 Conductor Aluminum, Tape Shielded Cable, 3\/0 AWG 3C XLPE Insulation, PVC Jacket, 5kV-35kV Cable, High Voltage Cable, 3\/0 AWG 3C Aluminum MV-90, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use, 1\/0 AWG and larger.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Oil Resistance I jacket.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawnAluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset crosslinked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape, 5 mil thick, 25% minimum overlap\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or covered conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e  Black sunlight resistance and flame retardant polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 3\/0 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19 \u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.42 \u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG:\u003c\/strong\u003e 2 \u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 1.95 \u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 1885 \u003c\/span\u003e\u003c\/p\u003e","brand":"Aluminum MV-90 Cable","offers":[{"title":"Default Title","offer_id":52063925731697,"sku":"NNC29MV-90","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1234_18ad09b0-e4b9-44fc-baca-7d052eb6f363.jpg?v=1756205549"},{"product_id":"4-0-awg-3c-aluminum-mv-90-tape-shielded-xlpe-100-insulation-115-mil-8-kv","title":"4\/0 AWG 3C Aluminum MV-90 Tape Shielded XLPE 100% Insulation 115 mil 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-04-mv90-3c-xlpe-pvc_2_1.pdf?v=1756206451\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e4\/0 AWG 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried where permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e4\/0 AWG 3C MV-90 Cable, 3 Conductor Aluminum, Tape Shielded Cable, 4\/0 AWG 3C XLPE Insulation, PVC Jacket, 5kV-35kV Cable, High Voltage Cable, 4\/0 AWG 3C Aluminum MV-90, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use, 1\/0 AWG and larger.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Oil Resistance I jacket.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawnAluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset crosslinked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape, 5 mil thick, 25% minimum overlap\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or covered conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e  Black sunlight resistance and flame retardant polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 4\/0 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19 \u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.48 \u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG:\u003c\/strong\u003e 2 \u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 2.06\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 2119\u003c\/span\u003e\u003c\/p\u003e","brand":"Aluminum MV-90 Cable","offers":[{"title":"Default Title","offer_id":52063926485361,"sku":"NNC30MV-90","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1234_18ad09b0-e4b9-44fc-baca-7d052eb6f363.jpg?v=1756205549"},{"product_id":"250-mcm-3c-aluminum-mv-90-tape-shielded-xlpe-100-insulation-115-mil-8-kv","title":"250 MCM 3C Aluminum MV-90 Tape Shielded XLPE 100% Insulation 115 mil 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-04-mv90-3c-xlpe-pvc_2_1.pdf?v=1756206451\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e250 MCM 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried where permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e250 MCM 3C MV-90 Cable, 3 Conductor Aluminum, Tape Shielded Cable, 250 MCM 3C XLPE Insulation, PVC Jacket, 5kV-35kV Cable, High Voltage Cable, 250 MCM 3C Aluminum MV-90, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use, 1\/0 AWG and larger.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Oil Resistance I jacket.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawnAluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset crosslinked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape, 5 mil thick, 25% minimum overlap\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or covered conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e  Black sunlight resistance and flame retardant polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 250 MCM\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 37 \u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.52 \u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG:\u003c\/strong\u003e 2 \u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 2.19 \u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 2343 \u003c\/span\u003e\u003c\/p\u003e","brand":"Aluminum MV-90 Cable","offers":[{"title":"Default Title","offer_id":52063931728241,"sku":"NNC31MV-90","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1234_18ad09b0-e4b9-44fc-baca-7d052eb6f363.jpg?v=1756205549"},{"product_id":"300-mcm-3c-aluminum-mv-90-tape-shielded-xlpe-100-insulation-115-mil-8-kv","title":"300 MCM 3C Aluminum MV-90 Tape Shielded XLPE 100% Insulation 115 mil 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-04-mv90-3c-xlpe-pvc_2_1.pdf?v=1756206451\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e300 MCM 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried where permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e300 MCM 3C MV-90 Cable, 3 Conductor Aluminum, Tape Shielded Cable, 300 MCM 3C XLPE Insulation, PVC Jacket, 5kV-35kV Cable, High Voltage Cable, 300 MCM 3C Aluminum MV-90, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use, 1\/0 AWG and larger.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Oil Resistance I jacket.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawnAluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset crosslinked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape, 5 mil thick, 25% minimum overlap\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or covered conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e  Black sunlight resistance and flame retardant polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 300 MCM\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 37 \u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.57 \u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG:\u003c\/strong\u003e 1 \u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 2.29 \u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 2627  \u003c\/span\u003e\u003c\/p\u003e","brand":"Aluminum MV-90 Cable","offers":[{"title":"Default Title","offer_id":52063932285297,"sku":"NNC32MV-90","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1234_18ad09b0-e4b9-44fc-baca-7d052eb6f363.jpg?v=1756205549"},{"product_id":"350-mcm-3c-aluminum-mv-90-tape-shielded-xlpe-100-insulation-115-mil-8-kv","title":"350 MCM 3C Aluminum MV-90 Tape Shielded XLPE 100% Insulation 115 mil 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-04-mv90-3c-xlpe-pvc_2_1.pdf?v=1756206451\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e350 MCM 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried where permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e350 MCM 3C MV-90 Cable, 3 Conductor Aluminum, Tape Shielded Cable, 350 MCM 3C XLPE Insulation, PVC Jacket, 5kV-35kV Cable, High Voltage Cable, 350 MCM 3C Aluminum MV-90, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use, 1\/0 AWG and larger.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Oil Resistance I jacket.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawnAluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset crosslinked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape, 5 mil thick, 25% minimum overlap\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or covered conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e  Black sunlight resistance and flame retardant polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 350 MCM\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 37 \u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.62 \u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG:\u003c\/strong\u003e 1 \u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 2.39 \u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 2872\u003c\/span\u003e\u003c\/p\u003e","brand":"Aluminum MV-90 Cable","offers":[{"title":"Default Title","offer_id":52063932580209,"sku":"NNC33MV-90","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1234_18ad09b0-e4b9-44fc-baca-7d052eb6f363.jpg?v=1756205549"},{"product_id":"400-mcm-3c-aluminum-mv-90-tape-shielded-xlpe-100-insulation-115-mil-8-kv","title":"400 MCM 3C Aluminum MV-90 Tape Shielded XLPE 100% Insulation 115 mil 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-04-mv90-3c-xlpe-pvc_2_1.pdf?v=1756206451\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e400 MCM 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried where permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e400 MCM 3C MV-90 Cable, 3 Conductor Aluminum, Tape Shielded Cable, 400 MCM 3C XLPE Insulation, PVC Jacket, 5kV-35kV Cable, High Voltage Cable, 400 MCM 3C Aluminum MV-90, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use, 1\/0 AWG and larger.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Oil Resistance I jacket.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawnAluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset crosslinked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape, 5 mil thick, 25% minimum overlap\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or covered conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e  Black sunlight resistance and flame retardant polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 400 MCM\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 37 \u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.66 \u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG:\u003c\/strong\u003e 1 \u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 2.48\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 3110 \u003c\/span\u003e\u003c\/p\u003e","brand":"Aluminum MV-90 Cable","offers":[{"title":"Default Title","offer_id":52063932973425,"sku":"NNC34MV-90","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1234_18ad09b0-e4b9-44fc-baca-7d052eb6f363.jpg?v=1756205549"},{"product_id":"500-mcm-3c-aluminum-mv-90-tape-shielded-xlpe-100-insulation-115-mil-8-kv","title":"500 MCM 3C Aluminum MV-90 Tape Shielded XLPE 100% Insulation 115 mil 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-04-mv90-3c-xlpe-pvc_2_1.pdf?v=1756206451\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e500 MCM 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried where permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e500 MCM 3C MV-90 Cable, 3 Conductor Aluminum, Tape Shielded Cable, 500 MCM 3C XLPE Insulation, PVC Jacket, 5kV-35kV Cable, High Voltage Cable, 500 MCM 3C Aluminum MV-90, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use, 1\/0 AWG and larger.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Oil Resistance I jacket.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawnAluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset crosslinked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape, 5 mil thick, 25% minimum overlap\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or covered conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e  Black sunlight resistance and flame retardant polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 500 MCM\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 37 \u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.74\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG:\u003c\/strong\u003e 1\/0 \u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 140 \u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 2.76 \u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 3880\u003c\/span\u003e\u003c\/p\u003e","brand":"Aluminum MV-90 Cable","offers":[{"title":"Default Title","offer_id":52063939461489,"sku":"NNC35MV-90","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1234_18ad09b0-e4b9-44fc-baca-7d052eb6f363.jpg?v=1756205549"},{"product_id":"600-mcm-3c-aluminum-mv-90-tape-shielded-xlpe-100-insulation-115-mil-8-kv","title":"600 MCM 3C Aluminum MV-90 Tape Shielded XLPE 100% Insulation 115 mil 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-04-mv90-3c-xlpe-pvc_2_1.pdf?v=1756206451\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e600 MCM 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried where permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e600 MCM 3C MV-90 Cable, 3 Conductor Aluminum, Tape Shielded Cable, 600 MCM 3C XLPE Insulation, PVC Jacket, 5kV-35kV Cable, High Voltage Cable, 600 MCM 3C Aluminum MV-90, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use, 1\/0 AWG and larger.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Oil Resistance I jacket.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawnAluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset crosslinked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape, 5 mil thick, 25% minimum overlap\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or covered conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e  Black sunlight resistance and flame retardant polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 600 MCM\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 61\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.81\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG:\u003c\/strong\u003e 1\/0 \u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 140 \u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 2.95 \u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 4326 \u003c\/span\u003e\u003c\/p\u003e","brand":"Aluminum MV-90 Cable","offers":[{"title":"Default Title","offer_id":52063940280689,"sku":"NNC36MV-90","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1234_18ad09b0-e4b9-44fc-baca-7d052eb6f363.jpg?v=1756205549"},{"product_id":"750-mcm-3c-aluminum-mv-90-tape-shielded-xlpe-100-insulation-115-mil-8-kv","title":"750 MCM 3C Aluminum MV-90 Tape Shielded XLPE 100% Insulation 115 mil 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-04-mv90-3c-xlpe-pvc_2_1.pdf?v=1756206451\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e750 MCM 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried where permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e750 MCM 3C MV-90 Cable, 3 Conductor Aluminum, Tape Shielded Cable, 750 MCM 3C XLPE Insulation, PVC Jacket, 5kV-35kV Cable, High Voltage Cable, 750 MCM 3C Aluminum MV-90, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use, 1\/0 AWG and larger.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Oil Resistance I jacket.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawnAluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset crosslinked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape, 5 mil thick, 25% minimum overlap\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or covered conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e  Black sunlight resistance and flame retardant polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 750 MCM\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 61\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.91 \u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG:\u003c\/strong\u003e 2\/0 \u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 140 \u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 3.16\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 5045  \u003c\/span\u003e\u003c\/p\u003e","brand":"Aluminum MV-90 Cable","offers":[{"title":"Default Title","offer_id":52063940804977,"sku":"NNC37MV-90","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1234_18ad09b0-e4b9-44fc-baca-7d052eb6f363.jpg?v=1756205549"},{"product_id":"1000-mcm-3c-aluminum-mv-90-tape-shielded-xlpe-100-insulation-115-mil-8-kv","title":"1000 MCM 3C Aluminum MV-90 Tape Shielded XLPE 100% Insulation 115 mil 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-04-mv90-3c-xlpe-pvc_2_1.pdf?v=1756206451\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1000 MCM 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried where permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e1000 MCM 3C MV-90 Cable, 3 Conductor Aluminum, Tape Shielded Cable, 1000 MCM 3C XLPE Insulation, PVC Jacket, 5kV-35kV Cable, High Voltage Cable, 1000 MCM 3C Aluminum MV-90, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use, 1\/0 AWG and larger.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Oil Resistance I jacket.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawnAluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset crosslinked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape, 5 mil thick, 25% minimum overlap\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or covered conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e  Black sunlight resistance and flame retardant polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1000 MCM\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 61\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 1.06 \u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG:\u003c\/strong\u003e 3\/0\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 140 \u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 3.49 \u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 6136\u003c\/span\u003e\u003c\/p\u003e","brand":"Aluminum MV-90 Cable","offers":[{"title":"Default Title","offer_id":52063941132657,"sku":"NNC38MV-90","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1234_18ad09b0-e4b9-44fc-baca-7d052eb6f363.jpg?v=1756205549"},{"product_id":"6-awg-3c-aluminum-mv-90-tape-shielded-xlpe-133-insulation-140-mil-8-kv","title":"6 AWG 3C Aluminum MV-90 Tape Shielded XLPE 133% Insulation 140 mil 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-04-mv90-3c-xlpe-pvc_2_1.pdf?v=1756206451\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e6 AWG 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried where permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e6 AWG 3C MV-90 Cable, 3 Conductor Aluminum, Tape Shielded Cable, 6 AWG 3C XLPE Insulation, PVC Jacket, 5kV-35kV Cable, High Voltage Cable, 6 AWG 3C Aluminum MV-90, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use, 1\/0 AWG and larger.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Oil Resistance I jacket.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawnAluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset crosslinked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape, 5 mil thick, 25% minimum overlap\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or covered conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e  Black sunlight resistance and flame retardant polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 6 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 7\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.17\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG:\u003c\/strong\u003e 6\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 80 \u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 1.45 \u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 938\u003c\/span\u003e\u003c\/p\u003e","brand":"Aluminum MV-90 Cable","offers":[{"title":"Default Title","offer_id":52063942934897,"sku":"NNC39MV-90","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1444_c1a58366-b5d9-482d-8c9c-de2fa1ffd5c5.jpg?v=1756381870"},{"product_id":"4-awg-3c-aluminum-mv-90-tape-shielded-xlpe-133-insulation-140-mil-8-kv","title":"4 AWG 3C Aluminum MV-90 Tape Shielded XLPE 133% Insulation 140 mil 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-04-mv90-3c-xlpe-pvc_2_1.pdf?v=1756206451\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e4 AWG 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried where permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e4 AWG 3C MV-90 Cable, 3 Conductor Aluminum, Tape Shielded Cable, 4 AWG 3C XLPE Insulation, PVC Jacket, 5kV-35kV Cable, High Voltage Cable, 4 AWG 3C Aluminum MV-90, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use, 1\/0 AWG and larger.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Oil Resistance I jacket.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawnAluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset crosslinked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape, 5 mil thick, 25% minimum overlap\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or covered conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e  Black sunlight resistance and flame retardant polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 4 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 7\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.21 \u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG:\u003c\/strong\u003e 4\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 80 \u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 1.55 \u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 1064\u003c\/span\u003e\u003c\/p\u003e","brand":"Aluminum MV-90 Cable","offers":[{"title":"Default Title","offer_id":52063947161969,"sku":"NNC40MV-90","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1444_c1a58366-b5d9-482d-8c9c-de2fa1ffd5c5.jpg?v=1756381870"},{"product_id":"2-awg-3c-aluminum-mv-90-tape-shielded-xlpe-133-insulation-140-mil-8-kv","title":"2 AWG 3C Aluminum MV-90 Tape Shielded XLPE 133% Insulation 140 mil 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-04-mv90-3c-xlpe-pvc_2_1.pdf?v=1756206451\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2 AWG 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried where permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e2 AWG 3C MV-90 Cable, 3 Conductor Aluminum, Tape Shielded Cable, 2 AWG 3C XLPE Insulation, PVC Jacket, 5kV-35kV Cable, High Voltage Cable, 2 AWG 3C Aluminum MV-90, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use, 1\/0 AWG and larger.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Oil Resistance I jacket.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawnAluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset crosslinked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape, 5 mil thick, 25% minimum overlap\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or covered conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e  Black sunlight resistance and flame retardant polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 7\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.27\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG:\u003c\/strong\u003e 4\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 80 \u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 1.67 \u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 1240\u003c\/span\u003e\u003c\/p\u003e","brand":"Aluminum MV-90 Cable","offers":[{"title":"Default Title","offer_id":52063947293041,"sku":"NNC41MV-90","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1444_c1a58366-b5d9-482d-8c9c-de2fa1ffd5c5.jpg?v=1756381870"},{"product_id":"1-awg-3c-aluminum-mv-90-tape-shielded-xlpe-133-insulation-140-mil-8-kv","title":"1 AWG 3C Aluminum MV-90 Tape Shielded XLPE 133% Insulation 140 mil 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-04-mv90-3c-xlpe-pvc_2_1.pdf?v=1756206451\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1 AWG 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried where permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e1 AWG 3C MV-90 Cable, 3 Conductor Aluminum, Tape Shielded Cable, 1 AWG 3C XLPE Insulation, PVC Jacket, 5kV-35kV Cable, High Voltage Cable, 1 AWG 3C Aluminum MV-90, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use, 1\/0 AWG and larger.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Oil Resistance I jacket.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawnAluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset crosslinked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape, 5 mil thick, 25% minimum overlap\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or covered conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e  Black sunlight resistance and flame retardant polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19 \u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.30 \u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG:\u003c\/strong\u003e 4\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110 \u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 1.80\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 1498\u003c\/span\u003e\u003c\/p\u003e","brand":"Aluminum MV-90 Cable","offers":[{"title":"Default Title","offer_id":52063947587953,"sku":"NNC42MV-90","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1444_c1a58366-b5d9-482d-8c9c-de2fa1ffd5c5.jpg?v=1756381870"},{"product_id":"1-0-awg-3c-aluminum-mv-90-tape-shielded-xlpe-133-insulation-140-mil-8-kv","title":"1\/0 AWG 3C Aluminum MV-90 Tape Shielded XLPE 133% Insulation 140 mil 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-04-mv90-3c-xlpe-pvc_2_1.pdf?v=1756206451\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1\/0 AWG 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried where permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e1\/0 AWG 3C MV-90 Cable, 3 Conductor Aluminum, Tape Shielded Cable, 1\/0 AWG 3C XLPE Insulation, PVC Jacket, 5kV-35kV Cable, High Voltage Cable, 1\/0 AWG 3C Aluminum MV-90, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use, 1\/0 AWG and larger.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Oil Resistance I jacket.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawnAluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset crosslinked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape, 5 mil thick, 25% minimum overlap\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or covered conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e  Black sunlight resistance and flame retardant polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1\/0 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19 \u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.34  \u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG:\u003c\/strong\u003e 4\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110 \u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 1.88 \u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 1636\u003c\/span\u003e\u003c\/p\u003e","brand":"Aluminum MV-90 Cable","offers":[{"title":"Default Title","offer_id":52063948407153,"sku":"NNC43MV-90","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1444_c1a58366-b5d9-482d-8c9c-de2fa1ffd5c5.jpg?v=1756381870"},{"product_id":"2-0-awg-3c-aluminum-mv-90-tape-shielded-xlpe-133-insulation-140-mil-8-kv","title":"2\/0 AWG 3C Aluminum MV-90 Tape Shielded XLPE 133% Insulation 140 mil 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-04-mv90-3c-xlpe-pvc_2_1.pdf?v=1756206451\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2\/0 AWG 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried where permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e2\/0 AWG 3C MV-90 Cable, 3 Conductor Aluminum, Tape Shielded Cable, 2\/0 AWG 3C XLPE Insulation, PVC Jacket, 5kV-35kV Cable, High Voltage Cable, 2\/0 AWG 3C Aluminum MV-90, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use, 1\/0 AWG and larger.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Oil Resistance I jacket.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawnAluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset crosslinked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape, 5 mil thick, 25% minimum overlap\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or covered conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e  Black sunlight resistance and flame retardant polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2\/0 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19 \u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.38 \u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG:\u003c\/strong\u003e 2\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110 \u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 1.96\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 1830\u003c\/span\u003e\u003c\/p\u003e","brand":"Aluminum MV-90 Cable","offers":[{"title":"Default Title","offer_id":52063951290737,"sku":"NNC44MV-90","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1444_c1a58366-b5d9-482d-8c9c-de2fa1ffd5c5.jpg?v=1756381870"},{"product_id":"3-0-awg-3c-aluminum-mv-90-tape-shielded-xlpe-133-insulation-140-mil-8-kv","title":"3\/0 AWG 3C Aluminum MV-90 Tape Shielded XLPE 133% Insulation 140 mil 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-04-mv90-3c-xlpe-pvc_2_1.pdf?v=1756206451\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e3\/0 AWG 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried where permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e3\/0 AWG 3C MV-90 Cable, 3 Conductor Aluminum, Tape Shielded Cable, 3\/0 AWG 3C XLPE Insulation, PVC Jacket, 5kV-35kV Cable, High Voltage Cable, 3\/0 AWG 3C Aluminum MV-90, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use, 1\/0 AWG and larger.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Oil Resistance I jacket.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawnAluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset crosslinked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape, 5 mil thick, 25% minimum overlap\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or covered conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e  Black sunlight resistance and flame retardant polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 3\/0 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19 \u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e  0.42 \u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG:\u003c\/strong\u003e 2\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110 \u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 2.06\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 2030\u003c\/span\u003e\u003c\/p\u003e","brand":"Aluminum MV-90 Cable","offers":[{"title":"Default Title","offer_id":52063961055601,"sku":"NNC45MV-90","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1444_c1a58366-b5d9-482d-8c9c-de2fa1ffd5c5.jpg?v=1756381870"},{"product_id":"4-0-awg-3c-aluminum-mv-90-tape-shielded-xlpe-133-insulation-140-mil-8-kv","title":"4\/0 AWG 3C Aluminum MV-90 Tape Shielded XLPE 133% Insulation 140 mil 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-04-mv90-3c-xlpe-pvc_2_1.pdf?v=1756206451\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e4\/0 AWG 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried where permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e4\/0 AWG 3C MV-90 Cable, 3 Conductor Aluminum, Tape Shielded Cable, 4\/0 AWG 3C XLPE Insulation, PVC Jacket, 5kV-35kV Cable, High Voltage Cable, 4\/0 AWG 3C Aluminum MV-90, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use, 1\/0 AWG and larger.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Oil Resistance I jacket.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawnAluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset crosslinked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape, 5 mil thick, 25% minimum overlap\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or covered conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e  Black sunlight resistance and flame retardant polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 4\/0 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19 \u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e  0.48 \u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG:\u003c\/strong\u003e 2\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110 \u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 2.18 \u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 2271\u003c\/span\u003e\u003c\/p\u003e","brand":"Aluminum MV-90 Cable","offers":[{"title":"Default Title","offer_id":52063966953841,"sku":"NNC46MV-90","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1444_c1a58366-b5d9-482d-8c9c-de2fa1ffd5c5.jpg?v=1756381870"},{"product_id":"250-mcm-3c-aluminum-mv-90-tape-shielded-xlpe-133-insulation-140-mil-8-kv","title":"250 MCM 3C Aluminum MV-90 Tape Shielded XLPE 133% Insulation 140 mil 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-04-mv90-3c-xlpe-pvc_2_1.pdf?v=1756206451\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e250 MCM 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried where permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e250 MCM 3C MV-90 Cable, 3 Conductor Aluminum, Tape Shielded Cable, 250 MCM 3C XLPE Insulation, PVC Jacket, 5kV-35kV Cable, High Voltage Cable, 250 MCM 3C Aluminum MV-90, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use, 1\/0 AWG and larger.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Oil Resistance I jacket.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawnAluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset crosslinked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape, 5 mil thick, 25% minimum overlap\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or covered conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e  Black sunlight resistance and flame retardant polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 250 MCM\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 37 \u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e  0.52\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG:\u003c\/strong\u003e 2\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110 \u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 2.30 \u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 2502\u003c\/span\u003e\u003c\/p\u003e","brand":"Aluminum MV-90 Cable","offers":[{"title":"Default Title","offer_id":52063981732209,"sku":"NNC47MV-90","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1444_c1a58366-b5d9-482d-8c9c-de2fa1ffd5c5.jpg?v=1756381870"},{"product_id":"300-mcm-3c-aluminum-mv-90-tape-shielded-xlpe-133-insulation-140-mil-8-kv","title":"300 MCM 3C Aluminum MV-90 Tape Shielded XLPE 133% Insulation 140 mil 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-04-mv90-3c-xlpe-pvc_2_1.pdf?v=1756206451\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e300 MCM 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried where permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e300 MCM 3C MV-90 Cable, 3 Conductor Aluminum, Tape Shielded Cable, 300 MCM 3C XLPE Insulation, PVC Jacket, 5kV-35kV Cable, High Voltage Cable, 300 MCM 3C Aluminum MV-90, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use, 1\/0 AWG and larger.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Oil Resistance I jacket.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawnAluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset crosslinked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape, 5 mil thick, 25% minimum overlap\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or covered conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e  Black sunlight resistance and flame retardant polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 300 MCM\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 37 \u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e  0.57 \u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG:\u003c\/strong\u003e 1 \u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110 \u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 2.40 \u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 2793\u003c\/span\u003e\u003c\/p\u003e","brand":"Aluminum MV-90 Cable","offers":[{"title":"Default Title","offer_id":52063993561457,"sku":"NNC48MV-90","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1444_c1a58366-b5d9-482d-8c9c-de2fa1ffd5c5.jpg?v=1756381870"},{"product_id":"350-mcm-3c-aluminum-mv-90-tape-shielded-xlpe-133-insulation-140-mil-8-kv","title":"350 MCM 3C Aluminum MV-90 Tape Shielded XLPE 133% Insulation 140 mil 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-04-mv90-3c-xlpe-pvc_2_1.pdf?v=1756206451\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e350 MCM 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried where permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e350 MCM 3C MV-90 Cable, 3 Conductor Aluminum, Tape Shielded Cable, 350 MCM 3C XLPE Insulation, PVC Jacket, 5kV-35kV Cable, High Voltage Cable, 350 MCM 3C Aluminum MV-90, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use, 1\/0 AWG and larger.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Oil Resistance I jacket.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawnAluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset crosslinked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape, 5 mil thick, 25% minimum overlap\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or covered conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e  Black sunlight resistance and flame retardant polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 350 MCM\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 37 \u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e  0.62 \u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG:\u003c\/strong\u003e 1 \u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110 \u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 2.50\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 3043\u003c\/span\u003e\u003c\/p\u003e","brand":"Aluminum MV-90 Cable","offers":[{"title":"Default Title","offer_id":52064014762353,"sku":"NNC49MV-90","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1444_c1a58366-b5d9-482d-8c9c-de2fa1ffd5c5.jpg?v=1756381870"},{"product_id":"400-mcm-3c-aluminum-mv-90-tape-shielded-xlpe-133-insulation-140-mil-8-kv","title":"400 MCM 3C Aluminum MV-90 Tape Shielded XLPE 133% Insulation 140 mil 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-04-mv90-3c-xlpe-pvc_2_1.pdf?v=1756206451\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e400 MCM 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried where permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e400 MCM 3C MV-90 Cable, 3 Conductor Aluminum, Tape Shielded Cable, 400 MCM 3C XLPE Insulation, PVC Jacket, 5kV-35kV Cable, High Voltage Cable, 400 MCM 3C Aluminum MV-90, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use, 1\/0 AWG and larger.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Oil Resistance I jacket.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawnAluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset crosslinked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape, 5 mil thick, 25% minimum overlap\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or covered conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e  Black sunlight resistance and flame retardant polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 400 MCM\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 37 \u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e  0.66 \u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG:\u003c\/strong\u003e 1 \u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110 \u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 2.65 \u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 3378\u003c\/span\u003e\u003c\/p\u003e","brand":"Aluminum MV-90 Cable","offers":[{"title":"Default Title","offer_id":52064020529521,"sku":"NNC50MV-90","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1444_c1a58366-b5d9-482d-8c9c-de2fa1ffd5c5.jpg?v=1756381870"},{"product_id":"500-mcm-3c-aluminum-mv-90-tape-shielded-xlpe-133-insulation-140-mil-8-kv","title":"500 MCM 3C Aluminum MV-90 Tape Shielded XLPE 133% Insulation 140 mil 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-04-mv90-3c-xlpe-pvc_2_1.pdf?v=1756206451\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e500 MCM 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried where permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e500 MCM 3C MV-90 Cable, 3 Conductor Aluminum, Tape Shielded Cable, 500 MCM 3C XLPE Insulation, PVC Jacket, 5kV-35kV Cable, High Voltage Cable, 500 MCM 3C Aluminum MV-90, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use, 1\/0 AWG and larger.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Oil Resistance I jacket.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawnAluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset crosslinked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape, 5 mil thick, 25% minimum overlap\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or covered conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e  Black sunlight resistance and flame retardant polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 500 MCM\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 37 \u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e  0.74 \u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG:\u003c\/strong\u003e 1\/0\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 140 \u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 2.88 \u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 4077\u003c\/span\u003e\u003c\/p\u003e","brand":"Aluminum MV-90 Cable","offers":[{"title":"Default Title","offer_id":52064038158705,"sku":"NNC51MV-90","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1444_c1a58366-b5d9-482d-8c9c-de2fa1ffd5c5.jpg?v=1756381870"},{"product_id":"600-mcm-3c-aluminum-mv-90-tape-shielded-xlpe-133-insulation-140-mil-8-kv","title":"600 MCM 3C Aluminum MV-90 Tape Shielded XLPE 133% Insulation 140 mil 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-04-mv90-3c-xlpe-pvc_2_1.pdf?v=1756206451\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e600 MCM 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried where permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e600 MCM 3C MV-90 Cable, 3 Conductor Aluminum, Tape Shielded Cable, 600 MCM 3C XLPE Insulation, PVC Jacket, 5kV-35kV Cable, High Voltage Cable, 600 MCM 3C Aluminum MV-90, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use, 1\/0 AWG and larger.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Oil Resistance I jacket.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawnAluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset crosslinked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape, 5 mil thick, 25% minimum overlap\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or covered conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e  Black sunlight resistance and flame retardant polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 600 MCM\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 61 \u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e  0.81 \u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG:\u003c\/strong\u003e 1\/0\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 140 \u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 3.07 \u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 4535\u003c\/span\u003e\u003c\/p\u003e","brand":"Aluminum MV-90 Cable","offers":[{"title":"Default Title","offer_id":52064066896241,"sku":"NNC52MV-90","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1444_c1a58366-b5d9-482d-8c9c-de2fa1ffd5c5.jpg?v=1756381870"},{"product_id":"750-mcm-3c-aluminum-mv-90-tape-shielded-xlpe-133-insulation-140-mil-8-kv","title":"750 MCM 3C Aluminum MV-90 Tape Shielded XLPE 133% Insulation 140 mil 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-04-mv90-3c-xlpe-pvc_2_1.pdf?v=1756206451\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e750 MCM 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried where permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e750 MCM 3C MV-90 Cable, 3 Conductor Aluminum, Tape Shielded Cable, 750 MCM 3C XLPE Insulation, PVC Jacket, 5kV-35kV Cable, High Voltage Cable, 750 MCM 3C Aluminum MV-90, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use, 1\/0 AWG and larger.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Oil Resistance I jacket.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawnAluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset crosslinked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape, 5 mil thick, 25% minimum overlap\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or covered conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e  Black sunlight resistance and flame retardant polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 750 MCM\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 61 \u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e  0.91 \u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG:\u003c\/strong\u003e 2\/0 \u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 140 \u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 3.27  \u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 5266\u003c\/span\u003e\u003c\/p\u003e","brand":"Aluminum MV-90 Cable","offers":[{"title":"Default Title","offer_id":52064076169585,"sku":"NNC53MV-90","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1444_c1a58366-b5d9-482d-8c9c-de2fa1ffd5c5.jpg?v=1756381870"},{"product_id":"1000-mcm-3c-aluminum-mv-90-tape-shielded-xlpe-133-insulation-140-mil-8-kv","title":"1000 MCM 3C Aluminum MV-90 Tape Shielded XLPE 133% Insulation 140 mil 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-04-mv90-3c-xlpe-pvc_2_1.pdf?v=1756206451\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1000 MCM 3C Aluminum MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried where permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e1000 MCM 3C MV-90 Cable, 3 Conductor Aluminum, Tape Shielded Cable, 1000 MCM 3C XLPE Insulation, PVC Jacket, 5kV-35kV Cable, High Voltage Cable, 1000 MCM 3C Aluminum MV-90, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use, 1\/0 AWG and larger.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Oil Resistance I jacket.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawnAluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset crosslinked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape, 5 mil thick, 25% minimum overlap\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or covered conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e  Black sunlight resistance and flame retardant polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1000 MCM\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 61 \u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 1.06 \u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG:\u003c\/strong\u003e 3\/0 \u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 140 \u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 3.60\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 6376\u003c\/span\u003e\u003c\/p\u003e","brand":"Aluminum MV-90 Cable","offers":[{"title":"Default Title","offer_id":52064082887025,"sku":"NNC54MV-90","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1444_c1a58366-b5d9-482d-8c9c-de2fa1ffd5c5.jpg?v=1756381870"},{"product_id":"2-awg-3c-aluminum-mv-90-tape-shielded-xlpe-100-insulation-175-mil-15-kv","title":"2 AWG 3C Aluminum MV-90 Tape Shielded XLPE 100% Insulation 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-04-mv90-3c-xlpe-pvc_2_1.pdf?v=1756206451\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2 AWG 3C Aluminum MV-90 Tape Shielded XLPE 100% Insulation 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried where permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e2 AWG 3C MV-90 Cable, 3 Conductor Aluminum, Tape Shielded Cable, 2 AWG 3C XLPE Insulation, PVC Jacket, 5kV-35kV Cable, High Voltage Cable, 2 AWG 3C Aluminum MV-90, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use, 1\/0 AWG and larger.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Oil Resistance I jacket.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawnAluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset crosslinked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape, 5 mil thick, 25% minimum overlap\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or covered conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e  Black sunlight resistance and flame retardant polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 7\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.27 \u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG:\u003c\/strong\u003e 4 \u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 1.89\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Aluminum lb\/kft:\u003c\/strong\u003e 1533\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52075917279601,"sku":"NNC2175MV-90","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/22222222.jpg?v=1756441801"},{"product_id":"1-awg-3c-aluminum-mv-90-tape-shielded-xlpe-100-insulation-175-mil-15-kv","title":"1 AWG 3C Aluminum MV-90 Tape Shielded XLPE 100% Insulation 175 mil 15 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-04-mv90-3c-xlpe-pvc_2_1.pdf?v=1756206451\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1 AWG 3C Aluminum MV-90 Tape Shielded XLPE 100% Insulation 175 mil 15 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried where permitted by NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e1 AWG 3C MV-90 Cable, 3 Conductor Aluminum, Tape Shielded Cable, 1 AWG 3C XLPE Insulation, PVC Jacket, 5kV-35kV Cable, High Voltage Cable, 1 AWG 3C Aluminum MV-90, Electrical Power Cable, Multi-Conductor Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-93-639\/NEMA WC74\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 5 kV – 46 kV Shielded Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-97-682\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Utility Shielded Power Cables Rated 5 kV– 46 kV.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e AEIC CS8\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV – 46 kV.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated as Sunlight Resistance for CT use, 1\/0 AWG and larger.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Oil Resistance I jacket.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawnAluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset crosslinked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Semi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Soft annealed uncoated copper tape, 5 mil thick, 25% minimum overlap\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper or covered conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e  Black sunlight resistance and flame retardant polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19 \u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.30\u003cbr\u003e\u003cstrong\u003e• Ground Conductor Aluminum AWG:\u003c\/strong\u003e 4 \u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e 1.95\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Aluminum lb\/kft:\u003c\/strong\u003e 1689\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52075917410673,"sku":"NNC1175MV-90","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/22222222.jpg?v=1756441801"}],"url":"https:\/\/nassaunationalcable.com\/collections\/three-conductor-aluminum-mv-90-tape-shielded-xlpe-insulated-pvc-jacket-5-kv-35-kv.oembed?page=2","provider":"NassauNationalCable","version":"1.0","type":"link"}