{"title":"PLENUM RS-485 Shielded Cable 300V","description":"\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003ePLENUM RS-485 Shielded Cable 300V\u003c\/span\u003e\u003c\/h2\u003e","products":[{"product_id":"24-awg-1-pair-bare-copper-plenum-rs-485-shielded-cable-ul-listed-300v","title":"24 AWG 1 Pair Bare Copper Plenum RS-485 Shielded Cable UL LISTED 300V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/GENESIS-SPEC_RS-485-Shielded-Cable_Plenum_2_1.pdf?v=1776238055\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e24 AWG 1 Pair Bare Copper Plenum RS-485 Shielded Cable UL LISTED 300V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eGenesis Building Automation Cable delivers reliable high-speed data transmission and optimized performance for today’s smart building networks. Designed for the EIA 485 standard.\u003c\/p\u003e\n\u003cp\u003e• In fabricated ducts as described in NEC 300.22(B)\u003cbr\u003e• In other spaces used for environmental air as described in NEC 300.22(C)\u003cbr\u003e• In risers\u003cbr\u003e• Within buildings in other than air-handling spaces and risers\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e24 AWG Plenum Rated Data Communication Cable RS-485 Shielded Twisted Pair RS-485 Plenum Cable RS-485 Building Plenum Cable 300V Low Smoke Plenum RS-485 24 AWG Shielded Cable RS-485 Control \u0026amp; Signal Plenum Cable CMP Shielded Instrumentation Cable RS-485 RS-485 Network Communication 24 AWG Plenum Cable Fire Rated Plenum RS-485 Shielded Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eGenesis Building Automation Cable meets or exceeds the following specifications:\u003c\/p\u003e\n\u003cp\u003e• NFPA 262 – Plenum Rated\u003cbr\u003e• CSA C22.2 No. 2556 – FT6 Rated\u003cbr\u003e• UL 444 – Communication Cables, Type CMP\u003cbr\u003e• UL 1424 – Cables for Power-Limited Fire-Alarm Circuits, Type FPLP\u003cbr\u003e• UL 13 – Power-Limited Circuit Cables, Type CL3P\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e• Conductor: Bare Copper or Tinned Copper conductors for excellent signal transmission and low voltage drop\u003cbr\u003e• Insulation: FEP\u003cbr\u003e• Rip Cord: Durable rip cord for efficient jacket stripping and removal\u003cbr\u003e• Shield: Foil shield over all conductors\u003cbr\u003e• Jacket: Plenum PVC, Countdown Length Markings for easy tracking of usage remaining cable\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• SIZE: \u003c\/strong\u003e24\u003cspan\u003e AWG \u003cbr\u003e\u003cstrong\u003e• NUMBER OF PAIRS:\u003c\/strong\u003e 1\u003cbr\u003e\u003cstrong\u003e• SOLID \/ STRANDED:\u003c\/strong\u003e 7 strand\u003cbr\u003e\u003cstrong\u003e• NOMINAL O.D.(in):\u003c\/strong\u003e 0.179\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• DC RESISTANCE(Ohms\/1000ft. at 20ºC): \u003c\/strong\u003e26.7\u003cbr\u003e\u003cstrong\u003e• CAPACITANCE (pF\/ft. \u003c\/strong\u003e12.5\u003cbr\u003e\u003cstrong\u003e• WEIGHT (lbs.\/1000ft.):\u003c\/strong\u003e 17.1\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"width: 325.114px; height: 35.5966px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire(GENESIS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e3319\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63410650153329,"sku":"NNC3319","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_4_0290df64-7106-4489-9f1e-a42ba653310c.png?v=1775720493"},{"product_id":"22-awg-1-pair-bare-copper-plenum-rs-485-shielded-cable-ul-listed-300v","title":"22 AWG 1 Pair Bare Copper Plenum RS-485 Shielded Cable UL LISTED 300V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/GENESIS-SPEC_RS-485-Shielded-Cable_Plenum_2_1.pdf?v=1776238055\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e22 AWG 1 Pair Bare Copper Plenum RS-485 Shielded Cable UL LISTED 300V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eGenesis Building Automation Cable delivers reliable high-speed data transmission and optimized performance for today’s smart building networks. Designed for the EIA 485 standard.\u003c\/p\u003e\n\u003cp\u003e• In fabricated ducts as described in NEC 300.22(B)\u003cbr\u003e• In other spaces used for environmental air as described in NEC 300.22(C)\u003cbr\u003e• In risers\u003cbr\u003e• Within buildings in other than air-handling spaces and risers\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e22 AWG Plenum Rated Data Communication Cable RS-485 Shielded Twisted Pair RS-485 Plenum Cable RS-485 Building Plenum Cable 300V Low Smoke Plenum RS-485 22 AWG Shielded Cable RS-485 Control \u0026amp; Signal Plenum Cable CMP Shielded Instrumentation Cable RS-485 RS-485 Network Communication 22 AWG Plenum Cable Fire Rated Plenum RS-485 Shielded Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eGenesis Building Automation Cable meets or exceeds the following specifications:\u003c\/p\u003e\n\u003cp\u003e• NFPA 262 – Plenum Rated\u003cbr\u003e• CSA C22.2 No. 2556 – FT6 Rated\u003cbr\u003e• UL 444 – Communication Cables, Type CMP\u003cbr\u003e• UL 1424 – Cables for Power-Limited Fire-Alarm Circuits, Type FPLP\u003cbr\u003e• UL 13 – Power-Limited Circuit Cables, Type CL3P\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e• Conductor: Bare Copper or Tinned Copper conductors for excellent signal transmission and low voltage drop\u003cbr\u003e• Insulation: FEP\u003cbr\u003e• Rip Cord: Durable rip cord for efficient jacket stripping and removal\u003cbr\u003e• Shield: Foil shield over all conductors\u003cbr\u003e• Jacket: Plenum PVC, Countdown Length Markings for easy tracking of usage remaining cable\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• SIZE: \u003c\/strong\u003e22\u003cspan\u003e AWG \u003cbr\u003e\u003cstrong\u003e• NUMBER OF PAIRS:\u003c\/strong\u003e 1\u003cbr\u003e\u003cstrong\u003e• SOLID \/ STRANDED:\u003c\/strong\u003e 7 strand\u003cbr\u003e\u003cstrong\u003e• NOMINAL O.D.(in):\u003c\/strong\u003e 0.191\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• DC RESISTANCE(Ohms\/1000ft. at 20ºC): \u003c\/strong\u003e16.9\u003cbr\u003e\u003cstrong\u003e• CAPACITANCE (pF\/ft. \u003c\/strong\u003e12.5\u003cbr\u003e\u003cstrong\u003e• WEIGHT (lbs.\/1000ft.):\u003c\/strong\u003e 20.1\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 325.114px; height: 35.5966px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire(GENESIS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e3320\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63410679841137,"sku":"NNC3320","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_4_0290df64-7106-4489-9f1e-a42ba653310c.png?v=1775720493"},{"product_id":"18-awg-1-pair-bare-copper-plenum-rs-485-shielded-cable-ul-listed-300v","title":"18 AWG 1 Pair Bare Copper Plenum RS-485 Shielded Cable UL LISTED 300V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/GENESIS-SPEC_RS-485-Shielded-Cable_Plenum_2_1.pdf?v=1776238055\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e18 AWG 1 Pair Bare Copper Plenum RS-485 Shielded Cable UL LISTED 300V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eGenesis Building Automation Cable delivers reliable high-speed data transmission and optimized performance for today’s smart building networks. Designed for the EIA 485 standard.\u003c\/p\u003e\n\u003cp\u003e• In fabricated ducts as described in NEC 300.22(B)\u003cbr\u003e• In other spaces used for environmental air as described in NEC 300.22(C)\u003cbr\u003e• In risers\u003cbr\u003e• Within buildings in other than air-handling spaces and risers\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e18 AWG Plenum Rated Data Communication Cable RS-485 Shielded Twisted Pair RS-485 Plenum Cable RS-485 Building Plenum Cable 300V Low Smoke Plenum RS-485 18 AWG Shielded Cable RS-485 Control \u0026amp; Signal Plenum Cable CMP Shielded Instrumentation Cable RS-485 RS-485 Network Communication 18 AWG Plenum Cable Fire Rated Plenum RS-485 Shielded Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eGenesis Building Automation Cable meets or exceeds the following specifications:\u003c\/p\u003e\n\u003cp\u003e• NFPA 262 – Plenum Rated\u003cbr\u003e• CSA C22.2 No. 2556 – FT6 Rated\u003cbr\u003e• UL 444 – Communication Cables, Type CMP\u003cbr\u003e• UL 1424 – Cables for Power-Limited Fire-Alarm Circuits, Type FPLP\u003cbr\u003e• UL 13 – Power-Limited Circuit Cables, Type CL3P\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e• Conductor: Bare Copper or Tinned Copper conductors for excellent signal transmission and low voltage drop\u003cbr\u003e• Insulation: FEP\u003cbr\u003e• Rip Cord: Durable rip cord for efficient jacket stripping and removal\u003cbr\u003e• Shield: Foil shield over all conductors\u003cbr\u003e• Jacket: Plenum PVC, Countdown Length Markings for easy tracking of usage remaining cable\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• SIZE: \u003c\/strong\u003e22\u003cspan\u003e AWG \u003cbr\u003e\u003cstrong\u003e• NUMBER OF PAIRS:\u003c\/strong\u003e 1\u003cbr\u003e\u003cstrong\u003e• SOLID \/ STRANDED:\u003c\/strong\u003e 19 strand\u003cbr\u003e\u003cstrong\u003e• NOMINAL O.D.(in):\u003c\/strong\u003e 0.249\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• DC RESISTANCE(Ohms\/1000ft. at 20ºC): \u003c\/strong\u003e6.66\u003cbr\u003e\u003cstrong\u003e• CAPACITANCE (pF\/ft. \u003c\/strong\u003e34.2\u003cbr\u003e\u003cstrong\u003e• WEIGHT (lbs.\/1000ft.):\u003c\/strong\u003e 20.1\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 64.2614px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 41.2642px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 325.114px; height: 41.2642px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.9972px;\"\u003e\n\u003ctd style=\"width: 160.597px; height: 22.9972px;\"\u003e\u003cstrong\u003eSouthwire(GENESIS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px; height: 22.9972px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e3322\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63410683347313,"sku":"NNC3322","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_4_0290df64-7106-4489-9f1e-a42ba653310c.png?v=1775720493"},{"product_id":"24-awg-1-5-pair-bare-copper-plenum-rs-485-shielded-cable-ul-listed-300v","title":"24 AWG 1.5 Pair Bare Copper Plenum RS-485 Shielded Cable UL LISTED 300V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/GENESIS-SPEC_RS-485-Shielded-Cable_Plenum_2_1.pdf?v=1776238055\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e24 AWG 1.5 Pair Bare Copper Plenum RS-485 Shielded Cable UL LISTED 300V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eGenesis Building Automation Cable delivers reliable high-speed data transmission and optimized performance for today’s smart building networks. Designed for the EIA 485 standard.\u003c\/p\u003e\n\u003cp\u003e• In fabricated ducts as described in NEC 300.22(B)\u003cbr\u003e• In other spaces used for environmental air as described in NEC 300.22(C)\u003cbr\u003e• In risers\u003cbr\u003e• Within buildings in other than air-handling spaces and risers\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e24 AWG Plenum Rated Data Communication Cable RS-485 Shielded Twisted Pair RS-485 Plenum Cable RS-485 Building Plenum Cable 300V Low Smoke Plenum RS-485 24 AWG Shielded Cable RS-485 Control \u0026amp; Signal Plenum Cable CMP Shielded Instrumentation Cable RS-485 RS-485 Network Communication 24 AWG Plenum Cable Fire Rated Plenum RS-485 Shielded Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eGenesis Building Automation Cable meets or exceeds the following specifications:\u003c\/p\u003e\n\u003cp\u003e• NFPA 262 – Plenum Rated\u003cbr\u003e• CSA C22.2 No. 2556 – FT6 Rated\u003cbr\u003e• UL 444 – Communication Cables, Type CMP\u003cbr\u003e• UL 1424 – Cables for Power-Limited Fire-Alarm Circuits, Type FPLP\u003cbr\u003e• UL 13 – Power-Limited Circuit Cables, Type CL3P\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e• Conductor: Bare Copper or Tinned Copper conductors for excellent signal transmission and low voltage drop\u003cbr\u003e• Insulation: FEP\u003cbr\u003e• Rip Cord: Durable rip cord for efficient jacket stripping and removal\u003cbr\u003e• Shield: Foil shield over all conductors\u003cbr\u003e• Jacket: Plenum PVC, Countdown Length Markings for easy tracking of usage and remaining cable\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• SIZE: \u003c\/strong\u003e24\u003cspan\u003e AWG \u003cbr\u003e\u003cstrong\u003e• NUMBER OF PAIRS:\u003c\/strong\u003e 1.5\u003cbr\u003e\u003cstrong\u003e• SOLID \/ STRANDED:\u003c\/strong\u003e 7 strand\u003cbr\u003e\u003cstrong\u003e• NOMINAL O.D.(in):\u003c\/strong\u003e 0.191\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• DC RESISTANCE(Ohms\/1000ft. at 20ºC):\u003c\/strong\u003e 26.7\u003cbr\u003e\u003cstrong\u003e• CAPACITANCE (pF\/ft. \u003c\/strong\u003e12.5\u003cbr\u003e\u003cstrong\u003e• WEIGHT (lbs.\/1000ft.):\u003c\/strong\u003e 22.4\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 325.114px; height: 35.5966px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire(GENESIS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e3323\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63410692161905,"sku":"NNC3323","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_4_0290df64-7106-4489-9f1e-a42ba653310c.png?v=1775720493"},{"product_id":"22-awg-1-5-pair-bare-copper-plenum-rs-485-shielded-cable-ul-listed-300v","title":"22 AWG 1.5 Pair Bare Copper Plenum RS-485 Shielded Cable UL LISTED 300V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/GENESIS-SPEC_RS-485-Shielded-Cable_Plenum_2_1.pdf?v=1776238055\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e22 AWG 1.5 Pair Bare Copper Plenum RS-485 Shielded Cable UL LISTED 300V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eGenesis Building Automation Cable delivers reliable high-speed data transmission and optimized performance for today’s smart building networks. Designed for the EIA 485 standard.\u003c\/p\u003e\n\u003cp\u003e• In fabricated ducts as described in NEC 300.22(B)\u003cbr\u003e• In other spaces used for environmental air as described in NEC 300.22(C)\u003cbr\u003e• In risers\u003cbr\u003e• Within buildings in other than air-handling spaces and risers\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e22 AWG Plenum Rated Data Communication Cable RS-485 Shielded Twisted Pair RS-485 Plenum Cable RS-485 Building Plenum Cable 300V Low Smoke Plenum RS-485 22 AWG Shielded Cable RS-485 Control \u0026amp; Signal Plenum Cable CMP Shielded Instrumentation Cable RS-485 RS-485 Network Communication 22 AWG Plenum Cable Fire Rated Plenum RS-485 Shielded Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eGenesis Building Automation Cable meets or exceeds the following specifications:\u003c\/p\u003e\n\u003cp\u003e• NFPA 262 – Plenum Rated\u003cbr\u003e• CSA C22.2 No. 2556 – FT6 Rated\u003cbr\u003e• UL 444 – Communication Cables, Type CMP\u003cbr\u003e• UL 1424 – Cables for Power-Limited Fire-Alarm Circuits, Type FPLP\u003cbr\u003e• UL 13 – Power-Limited Circuit Cables, Type CL3P\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e• Conductor: Bare Copper or Tinned Copper conductors for excellent signal transmission and low voltage drop\u003cbr\u003e• Insulation: FEP\u003cbr\u003e• Rip Cord: Durable rip cord for efficient jacket stripping and removal\u003cbr\u003e• Shield: Foil shield over all conductors\u003cbr\u003e• Jacket: Plenum PVC, Countdown Length Markings for easy tracking of usage and remaining cable\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• SIZE: \u003c\/strong\u003e22\u003cspan\u003e AWG \u003cbr\u003e\u003cstrong\u003e• NUMBER OF PAIRS:\u003c\/strong\u003e 1.5\u003cbr\u003e\u003cstrong\u003e• SOLID \/ STRANDED:\u003c\/strong\u003e 7 strand\u003cbr\u003e\u003cstrong\u003e• NOMINAL O.D.(in):\u003c\/strong\u003e 0.204\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• DC RESISTANCE(Ohms\/1000ft. at 20ºC):\u003c\/strong\u003e 16.9\u003cbr\u003e\u003cstrong\u003e• CAPACITANCE (pF\/ft. \u003c\/strong\u003e12.5\u003cbr\u003e\u003cstrong\u003e• WEIGHT (lbs.\/1000ft.):\u003c\/strong\u003e 26.7\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 325.114px; height: 35.5966px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire(GENESIS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e3324\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63410707595633,"sku":"NNC3328","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_4_0290df64-7106-4489-9f1e-a42ba653310c.png?v=1775720493"},{"product_id":"22-awg-2-pair-bare-copper-plenum-rs-485-shielded-cable-ul-listed-300v","title":"22 AWG 2 Pair Bare Copper Plenum RS-485 Shielded Cable UL LISTED 300V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/GENESIS-SPEC_RS-485-Shielded-Cable_Plenum_2_1.pdf?v=1776238055\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e22 AWG 2 Pair Bare Copper Plenum RS-485 Shielded Cable UL LISTED 300V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eGenesis Building Automation Cable delivers reliable high-speed data transmission and optimized performance for today’s smart building networks. Designed for the EIA 485 standard.\u003c\/p\u003e\n\u003cp\u003e• In fabricated ducts as described in NEC 300.22(B)\u003cbr\u003e• In other spaces used for environmental air as described in NEC 300.22(C)\u003cbr\u003e• In risers\u003cbr\u003e• Within buildings in other than air-handling spaces and risers\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e22 AWG Plenum Rated Data Communication Cable RS-485 Shielded Twisted Pair RS-485 Plenum Cable RS-485 Building Plenum Cable 300V Low Smoke Plenum RS-485 22 AWG Shielded Cable RS-485 Control \u0026amp; Signal Plenum Cable CMP Shielded Instrumentation Cable RS-485 RS-485 Network Communication 22 AWG Plenum Cable Fire Rated Plenum RS-485 Shielded Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eGenesis Building Automation Cable meets or exceeds the following specifications:\u003c\/p\u003e\n\u003cp\u003e• NFPA 262 – Plenum Rated\u003cbr\u003e• CSA C22.2 No. 2556 – FT6 Rated\u003cbr\u003e• UL 444 – Communication Cables, Type CMP\u003cbr\u003e• UL 1424 – Cables for Power-Limited Fire-Alarm Circuits, Type FPLP\u003cbr\u003e• UL 13 – Power-Limited Circuit Cables, Type CL3P\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e• Conductor: Bare Copper or Tinned Copper conductors for excellent signal transmission and low voltage drop\u003cbr\u003e• Insulation: FEP\u003cbr\u003e• Rip Cord: Durable rip cord for efficient jacket stripping and removal\u003cbr\u003e• Shield: Foil shield over all conductors\u003cbr\u003e• Jacket: Plenum PVC, Countdown Length Markings for easy tracking of usage remaining cable\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• SIZE: \u003c\/strong\u003e22\u003cspan\u003e AWG \u003cbr\u003e\u003cstrong\u003e• NUMBER OF PAIRS:\u003c\/strong\u003e 2\u003cbr\u003e\u003cstrong\u003e• SOLID \/ STRANDED:\u003c\/strong\u003e 7 strand\u003cbr\u003e\u003cstrong\u003e• NOMINAL O.D.(in):\u003c\/strong\u003e 0.201\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• DC RESISTANCE(Ohms\/1000ft. at 20ºC):\u003c\/strong\u003e 16.9\u003cbr\u003e\u003cstrong\u003e• CAPACITANCE (pF\/ft. \u003c\/strong\u003e12.5\u003cbr\u003e\u003cstrong\u003e• WEIGHT (lbs.\/1000ft.):\u003c\/strong\u003e 32.6\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 325.114px; height: 35.5966px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire(GENESIS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e3328\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63410722242929,"sku":"NNC3328","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_4_0290df64-7106-4489-9f1e-a42ba653310c.png?v=1775720493"},{"product_id":"22-awg-1-pair-tinned-copper-plenum-rs-485-shielded-cable-etl-listed-300v","title":"22 AWG 1 Pair Tinned Copper Plenum RS-485 Shielded Cable ETL LISTED 300V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/GENESIS-SPEC_RS-485-Shielded-Cable_Plenum_2_1.pdf?v=1776238055\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e22 AWG 1 Pair Tinned Copper Plenum RS-485 Shielded Cable ETL LISTED 300V\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eGenesis Building Automation Cable delivers reliable high-speed data transmission and optimized performance for today’s smart building networks. Designed for the EIA 485 standard.\u003c\/p\u003e\n\u003cp\u003e• In fabricated ducts as described in NEC 300.22(B)\u003cbr\u003e• In other spaces used for environmental air as described in NEC 300.22(C)\u003cbr\u003e• In risers\u003cbr\u003e• Within buildings in other than air-handling spaces and risers\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e22 AWG Plenum Rated Data Communication Cable RS-485 Shielded Twisted Pair RS-485 Plenum Cable RS-485 Building Plenum Cable 300V Low Smoke Plenum RS-485 22 AWG Shielded Cable RS-485 Control \u0026amp; Signal Plenum Cable CMP Shielded Instrumentation Cable RS-485 RS-485 Network Communication 22 AWG Plenum Cable Fire Rated Plenum RS-485 Shielded Cable\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eGenesis Building Automation Cable meets or exceeds the following specifications:\u003c\/p\u003e\n\u003cp\u003e• NFPA 262 – Plenum Rated\u003cbr\u003e• CSA C22.2 No. 2556 – FT6 Rated\u003cbr\u003e• UL 444 – Communication Cables, Type CMP\u003cbr\u003e• UL 1424 – Cables for Power-Limited Fire-Alarm Circuits, Type FPLP\u003cbr\u003e• UL 13 – Power-Limited Circuit Cables, Type CL3P\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e• Conductor: Bare Copper or Tinned Copper conductors for excellent signal transmission and low voltage drop\u003cbr\u003e• Insulation: FEP\u003cbr\u003e• Rip Cord: Durable rip cord for efficient jacket stripping and removal\u003cbr\u003e• Shield: Foil shield over all conductors\u003cbr\u003e• Jacket: Plenum PVC, Countdown Length Markings for easy tracking of usage remaining cable\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• SIZE: \u003c\/strong\u003e22\u003cspan\u003e AWG \u003cbr\u003e\u003cstrong\u003e• NUMBER OF PAIRS:\u003c\/strong\u003e 1\u003cbr\u003e\u003cstrong\u003e• SOLID \/ STRANDED:\u003c\/strong\u003e 7 strand\u003cbr\u003e\u003cstrong\u003e• NOMINAL O.D.(in):\u003c\/strong\u003e 0.185\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• DC RESISTANCE(Ohms\/1000ft. at 20ºC):\u003c\/strong\u003e 16.9\u003cbr\u003e\u003cstrong\u003e• CAPACITANCE (pF\/ft. \u003c\/strong\u003e14.5\u003cbr\u003e\u003cstrong\u003e• WEIGHT (lbs.\/1000ft.):\u003c\/strong\u003e 18.8\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"width: 325.114px; height: 35.5966px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire(GENESIS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e3251\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63410724471153,"sku":"NNC3251","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_4_0290df64-7106-4489-9f1e-a42ba653310c.png?v=1775720493"}],"url":"https:\/\/nassaunationalcable.com\/collections\/plenum-rs-485-shielded-cable-300v.oembed","provider":"NassauNationalCable","version":"1.0","type":"link"}