{"title":"OKONITE FMR-N X-OLENE FMR 600 VOLT INSTRUMENTATION CABLE PAIRS OR TRIADS - OVERALL SHIELD TYPE P-OS 90 DEG. C RATING","description":"","products":[{"product_id":"267-16-2301-okonite-fmr-n-x-olene-fmr-600-volt-instrumentation-cable-1-pair-overall-shield-type-p-os-18-awg","title":"267-16-2301 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable,  1 Pair - Overall Shield Type P-OS - 18 AWG","description":"\u003ch2\u003e\u003cb\u003e267-16-2301 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable, 1 Pair - Overall Shield Type P-OS - 18 AWG\u003c\/b\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene FMR 600 Volt cable is a special cable used in nuclear plants. It is a flame-retardant and physically tough instrumentation cable with an improved version of EPR insulation. The cable is resistant to heat, oil, moisture, and chemicals. Some of the typical uses of this cable include but are not limited to power plants, substations, and critical circuits. The operating temperature of the cable is 90°C. It is approved for installations in conduits and cable trays when supported by the messenger wire. Moreover, the cable is approved for direct burial. \u003c\/span\u003e \u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene is equally suitable for indoor and outdoor installations. Despite the fact that it is rugged, the cable is lightweight.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eokonite, okonite cable, okonite wire, okonite instrument cable, instrumentation cable, instrument tray cable, direct burial cable, nuclear plant cable, control cable, okonite control cable, P-OS cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE Standard - 383 LOCA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eICEA S-73-532\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass 1E\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE 383 and 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass B tinned copper conductor. The pairs are color-coded in black and white, and the triads are color-coded in black, white, and red. The conductors are assembled with a left-hand lay, and fillers resistant to flames are placed in between.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N improved EPR insulation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe X-Olene FMR thermoset jacket.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe shielding is full-coverage copper-polyester-Nomex tape and a 7- coated tinned copper drain wire that reflects the size of the conductor.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cb\u003e\n\u003cli\u003eCatalog Number: ​​267-16-2301\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eAWG: 18\/7 strands\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNumber of Pairs: 1\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eJacket Thickness: 45 mil\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNominal Diameter: 0.31 inches\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eCross-sectional Area: 0.08 sq inches \u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNet Weight (lbs\/1000): 49\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eShip Weight (lbs\/1000): 60\u003c\/li\u003e\n\u003c\/b\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27562495082596,"sku":"NNC9283X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/okonite-fmr-n-x-olene-fmr_32.jpg?v=1762462561"},{"product_id":"267-16-2302-okonite-fmr-n-x-olene-fmr-600-volt-instrumentation-cable-2-pairs-overall-shield-type-p-os-18-awg","title":"267-16-2302 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable,  2 Pairs - Overall Shield Type P-OS - 18 AWG","description":"\u003ch2\u003e\u003cb\u003e267-16-2302 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable, 2 Pairs - Overall Shield Type P-OS - 18 AWG\u003c\/b\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene FMR 600 Volt cable is a special cable used in nuclear plants. It is a flame-retardant and physically tough instrumentation cable with an improved version of EPR insulation. The cable is resistant to heat, oil, moisture, and chemicals. Some of the typical uses of this cable include but are not limited to power plants, substations, and critical circuits. The operating temperature of the cable is 90°C. It is approved for installations in conduits and cable trays when supported by the messenger wire. Moreover, the cable is approved for direct burial. \u003c\/span\u003e \u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene is equally suitable for indoor and outdoor installations. Despite the fact that it is rugged, the cable is lightweight.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e267-16-2302 okonite, okonite cable, okonite wire, okonite instrument cable, instrumentation cable, instrument tray cable, direct burial cable, nuclear plant cable, control cable, okonite control cable, P-OS cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE Standard - 383 LOCA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eICEA S-73-532\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass 1E\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE 383 and 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass B tinned copper conductor. The pairs are color-coded in black and white, and the triads are color-coded in black, white, and red. The conductors are assembled with a left-hand lay, and fillers resistant to flames are placed in between.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N improved EPR insulation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe X-Olene FMR thermoset jacket.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe shielding is full-coverage copper-polyester-Nomex tape and a 7- coated tinned copper drain wire that reflects the size of the conductor.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cb\u003e\n\u003cli\u003eCatalog Number: ​​267-16-2302\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eAWG: 18\/7 strands\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNumber of Pairs: 2\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eJacket Thickness: 45 mil\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNominal Diameter: 0.42 inches\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eCross-sectional Area: 0.14 sq inches \u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNet Weight (lbs\/1000): 98\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eShip Weight (lbs\/1000): 121\u003c\/li\u003e\n\u003c\/b\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27562495279204,"sku":"NNC9284X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/okonite-fmr-n-x-olene-fmr_32_408e6a95-a263-4b03-b751-4ff0a0864fc5.jpg?v=1759805685"},{"product_id":"267-16-2304-okonite-fmr-n-x-olene-fmr-600-volt-instrumentation-cable-4-pairs-overall-shield-type-p-os-18-awg","title":"267-16-2304 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable,  4 Pairs - Overall Shield Type P-OS - 18 AWG","description":"\u003ch2\u003e\u003cb\u003e267-16-2304 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable, 4 Pairs - Overall Shield Type P-OS - 18 AWG\u003c\/b\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene FMR 600 Volt cable is a special cable used in nuclear plants. It is a flame-retardant and physically tough instrumentation cable with an improved version of EPR insulation. The cable is resistant to heat, oil, moisture, and chemicals. Some of the typical uses of this cable include but are not limited to power plants, substations, and critical circuits. The operating temperature of the cable is 90°C. It is approved for installations in conduits and cable trays when supported by the messenger wire. Moreover, the cable is approved for direct burial. \u003c\/span\u003e \u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene is equally suitable for indoor and outdoor installations. Despite the fact that it is rugged, the cable is lightweight.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e267-16-2304 okonite, okonite cable, okonite wire, okonite instrument cable, instrumentation cable, instrument tray cable, direct burial cable, nuclear plant cable, control cable, okonite control cable, P-OS cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE Standard - 383 LOCA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eICEA S-73-532\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass 1E\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE 383 and 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass B tinned copper conductor. The pairs are color-coded in black and white, and the triads are color-coded in black, white, and red. The conductors are assembled with a left-hand lay, and fillers resistant to flames are placed in between.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N improved EPR insulation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe X-Olene FMR thermoset jacket.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe shielding is full-coverage copper-polyester-Nomex tape and a 7- coated tinned copper drain wire that reflects the size of the conductor.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cb\u003e\n\u003cli\u003eCatalog Number: ​​267-16-2304\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eAWG: 18\/7 strands\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNumber of Pairs: 4\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eJacket Thickness: 60 mil\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNominal Diameter: 0.60 inches\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eCross-sectional Area: 0.28 sq inches \u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNet Weight (lbs\/1000): 152\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eShip Weight (lbs\/1000): 176\u003c\/li\u003e\n\u003c\/b\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27562495475812,"sku":"NNC9285X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/okonite-fmr-n-x-olene-fmr_32_d49c3a73-6fe7-47fe-ac36-5be8cacbe02e.jpg?v=1762462563"},{"product_id":"267-16-2308-okonite-fmr-n-x-olene-fmr-600-volt-instrumentation-cable-8-pairs-overall-shield-type-p-os-18-awg","title":"267-16-2308 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable,  8 Pairs - Overall Shield Type P-OS - 18 AWG","description":"\u003ch2\u003e\u003cb\u003e267-16-2308 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable, 8 Pairs - Overall Shield Type P-OS - 18 AWG\u003c\/b\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene FMR 600 Volt cable is a special cable used in nuclear plants. It is a flame-retardant and physically tough instrumentation cable with an improved version of EPR insulation. The cable is resistant to heat, oil, moisture, and chemicals. Some of the typical uses of this cable include but are not limited to power plants, substations, and critical circuits. The operating temperature of the cable is 90°C. It is approved for installations in conduits and cable trays when supported by the messenger wire. Moreover, the cable is approved for direct burial. \u003c\/span\u003e \u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene is equally suitable for indoor and outdoor installations. Despite the fact that it is rugged, the cable is lightweight.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e267-16-2308 okonite, okonite cable, okonite wire, okonite instrument cable, instrumentation cable, instrument tray cable, direct burial cable, nuclear plant cable, control cable, okonite control cable, P-OS cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE Standard - 383 LOCA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eICEA S-73-532\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass 1E\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE 383 and 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass B tinned copper conductor. The pairs are color-coded in black and white, and the triads are color-coded in black, white, and red. The conductors are assembled with a left-hand lay, and fillers resistant to flames are placed in between.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N improved EPR insulation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe X-Olene FMR thermoset jacket.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe shielding is full-coverage copper-polyester-Nomex tape and a 7- coated tinned copper drain wire that reflects the size of the conductor.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cb\u003e\n\u003cli\u003eCatalog Number: ​​267-16-2308\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eAWG: 18\/7 strands\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNumber of Pairs: 8\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eJacket Thickness: 60 mil\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNominal Diameter: 0.86 inches\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eCross-sectional Area: 0.58 sq inches \u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNet Weight (lbs\/1000): 352\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eShip Weight (lbs\/1000): 416\u003c\/li\u003e\n\u003c\/b\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductors:\u003c\/strong\u003e Tinned copper per ASTM B-33, Class B stranded per ASTM B-8.\u003cbr\u003e \u003cstrong\u003eInsulation: \u003c\/strong\u003eOkonite FMR-N meets or exceeds the electrical and physical requirements of ICEA S-73-532\u003cbr\u003e \u003cstrong\u003eConductor Identification: \u003c\/strong\u003ePigmented black and white in pairs, black, white and red in triads; white conductor numerically printed for group identification. \u003cbr\u003e \u003cstrong\u003eAssembly: \u003c\/strong\u003ePairs or triads assembled with left-hand lay. Flame-retardant, non-wicking fillers included where required to provide a round cable.\u003cbr\u003e \u003cstrong\u003eCable Shield:\u003c\/strong\u003e Copper\/Polyester\/Nomex tape overlapped to provide 100% coverage, and a 7-strand tinned copper drain wire, same size as conductor.\u003cbr\u003e \u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e The X-Olene FMR compound meets or exceeds the requirements of thermoset jackets given in ICEA S-73-532.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eQualified as Class 1E cable\u003c\/li\u003e\n\u003cli\u003eFlame retardant - passes the IEEE 383 and 1202 flame test requirements.\u003c\/li\u003e\n\u003cli\u003eQuality Assurance traceability\u003c\/li\u003e\n\u003cli\u003e90°C rated control cable, factory assembled for indoor or outdoor installation in cable trays, in raceways, direct burial in the earth, or supported by messenger wire.\u003c\/li\u003e\n\u003cli\u003eMechanically rugged.\u003c\/li\u003e\n\u003cli\u003eColor coded conductors.\u003c\/li\u003e\n\u003cli\u003eResistant to water, oil and many chemicals.\u003c\/li\u003e\n\u003cli\u003eThermally stable at elevated temperatures.\u003c\/li\u003e\n\u003cli\u003eHigh insulation resistance, even at elevated temperatures.\u003c\/li\u003e\n\u003cli\u003eSmall diameter, lightweight.\u003c\/li\u003e\n\u003c\/ul\u003e\n[\/short]","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27562496098404,"sku":"NNC9286X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/okonite-fmr-n-x-olene-fmr_32_371f97b5-77f4-4c1a-9849-e486442073ac.jpg?v=1762462563"},{"product_id":"267-16-2312-okonite-fmr-n-x-olene-fmr-600-volt-instrumentation-cable-12-pairs-overall-shield-type-p-os-18-awg","title":"267-16-2312 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable,  12 Pairs - Overall Shield Type P-OS - 18 AWG","description":"\u003ch2\u003e\u003cb\u003e267-16-2312 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable, 12 Pairs - Overall Shield Type P-OS - 18 AWG\u003c\/b\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene FMR 600 Volt cable is a special cable used in nuclear plants. It is a flame-retardant and physically tough instrumentation cable with an improved version of EPR insulation. The cable is resistant to heat, oil, moisture, and chemicals. Some of the typical uses of this cable include but are not limited to power plants, substations, and critical circuits. The operating temperature of the cable is 90°C. It is approved for installations in conduits and cable trays when supported by the messenger wire. Moreover, the cable is approved for direct burial. \u003c\/span\u003e \u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene is equally suitable for indoor and outdoor installations. Despite the fact that it is rugged, the cable is lightweight.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e267-16-2312 okonite, okonite cable, okonite wire, okonite instrument cable, instrumentation cable, instrument tray cable, direct burial cable, nuclear plant cable, control cable, okonite control cable, P-OS cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE Standard - 383 LOCA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eICEA S-73-532\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass 1E\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE 383 and 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass B tinned copper conductor. The pairs are color-coded in black and white, and the triads are color-coded in black, white, and red. The conductors are assembled with a left-hand lay, and fillers resistant to flames are placed in between.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N improved EPR insulation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe X-Olene FMR thermoset jacket.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe shielding is full-coverage copper-polyester-Nomex tape and a 7- coated tinned copper drain wire that reflects the size of the conductor.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cb\u003e\n\u003cli\u003eCatalog Number: ​​267-16-2312\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eAWG: 18\/7 strands\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNumber of Pairs: 12\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eJacket Thickness: 80 mil\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNominal Diameter: 1.08 inches\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eCross-sectional Area: 0.92 sq inches \u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNet Weight (lbs\/1000): 527\u003c\/li\u003e\n\u003c\/b\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27562496262244,"sku":"NNC9287X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/okonite-fmr-n-x-olene-fmr_32_3519fe47-c204-4654-bb66-3598e8c542c2.jpg?v=1762462564"},{"product_id":"267-16-2316-okonite-fmr-n-x-olene-fmr-600-volt-instrumentation-cable-16-pairs-overall-shield-type-p-os-18-awg","title":"267-16-2316 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable,  16 Pairs - Overall Shield Type P-OS - 18 AWG","description":"\u003ch2\u003e\u003cb\u003e267-16-2316 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable, 16 Pairs - Overall Shield Type P-OS - 18 AWG\u003c\/b\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene FMR 600 Volt cable is a special cable used in nuclear plants. It is a flame-retardant and physically tough instrumentation cable with an improved version of EPR insulation. The cable is resistant to heat, oil, moisture, and chemicals. Some of the typical uses of this cable include but are not limited to power plants, substations, and critical circuits. The operating temperature of the cable is 90°C. It is approved for installations in conduits and cable trays when supported by the messenger wire. Moreover, the cable is approved for direct burial. \u003c\/span\u003e \u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene is equally suitable for indoor and outdoor installations. Despite the fact that it is rugged, the cable is lightweight.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e267-16-2316 okonite, okonite cable, okonite wire, okonite instrument cable, instrumentation cable, instrument tray cable, direct burial cable, nuclear plant cable, control cable, okonite control cable, P-OS cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE Standard - 383 LOCA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eICEA S-73-532\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass 1E\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE 383 and 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass B tinned copper conductor. The pairs are color-coded in black and white, and the triads are color-coded in black, white, and red. The conductors are assembled with a left-hand lay, and fillers resistant to flames are placed in between.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N improved EPR insulation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe X-Olene FMR thermoset jacket.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe shielding is full-coverage copper-polyester-Nomex tape and a 7- coated tinned copper drain wire that reflects the size of the conductor.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cb\u003e\n\u003cli\u003eCatalog Number: ​​267-16-2316\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eAWG: 18\/7 strands\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNumber of Pairs: 16\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eJacket Thickness: 80 mil\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNominal Diameter: 1.20 inches\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eCross-sectional Area: 1.13 sq inches \u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNet Weight (lbs\/1000): 624\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eShip Weight (lbs\/1000): 734\u003c\/li\u003e\n\u003c\/b\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27562496589924,"sku":"NNC9288X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/okonite-fmr-n-x-olene-fmr_32_c882185d-cc5d-4707-b00a-7e5a57c65e65.jpg?v=1759805685"},{"product_id":"267-16-2320-okonite-fmr-n-x-olene-fmr-600-volt-instrumentation-cable-20-pairs-overall-shield-type-p-os-18-awg","title":"267-16-2320 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable,  20 Pairs - Overall Shield Type P-OS - 18 AWG","description":"\u003ch2\u003e\u003cb\u003e267-16-2320 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable, 20 Pairs - Overall Shield Type P-OS - 18 AWG\u003c\/b\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene FMR 600 Volt cable is a special cable used in nuclear plants. It is a flame-retardant and physically tough instrumentation cable with an improved version of EPR insulation. The cable is resistant to heat, oil, moisture, and chemicals. Some of the typical uses of this cable include but are not limited to power plants, substations, and critical circuits. The operating temperature of the cable is 90°C. It is approved for installations in conduits and cable trays when supported by the messenger wire. Moreover, the cable is approved for direct burial. \u003c\/span\u003e \u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene is equally suitable for indoor and outdoor installations. Despite the fact that it is rugged, the cable is lightweight.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e267-16-2320 okonite, okonite cable, okonite wire, okonite instrument cable, instrumentation cable, instrument tray cable, direct burial cable, nuclear plant cable, control cable, okonite control cable, P-OS cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE Standard - 383 LOCA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eICEA S-73-532\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass 1E\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE 383 and 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass B tinned copper conductor. The pairs are color-coded in black and white, and the triads are color-coded in black, white, and red. The conductors are assembled with a left-hand lay, and fillers resistant to flames are placed in between.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N improved EPR insulation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe X-Olene FMR thermoset jacket.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe shielding is full-coverage copper-polyester-Nomex tape and a 7- coated tinned copper drain wire that reflects the size of the conductor.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cb\u003e\n\u003cli\u003eCatalog Number: ​​267-16-2320\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eAWG: 18\/7 strands\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNumber of Pairs: 20\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eJacket Thickness: 80 mil\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNominal Diameter: 1.33 inches\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eCross-sectional Area: 1.39 sq inches \u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNet Weight (lbs\/1000): 826\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eShip Weight (lbs\/1000): 932\u003c\/li\u003e\n\u003c\/b\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27562496688228,"sku":"NNC9289X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/okonite-fmr-n-x-olene-fmr_32_7d528938-4357-48d2-a664-84cc1d5f82e4.jpg?v=1762462566"},{"product_id":"267-16-2324-okonite-fmr-n-x-olene-fmr-600-volt-instrumentation-cable-24-pairs-overall-shield-type-p-os-18-awg","title":"267-16-2324 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable,  24 Pairs - Overall Shield Type P-OS - 18 AWG","description":"\u003ch2\u003e\u003cb\u003e267-16-2324 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable, 24 Pairs - Overall Shield Type P-OS - 18 AWG\u003c\/b\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene FMR 600 Volt cable is a special cable used in nuclear plants. It is a flame-retardant and physically tough instrumentation cable with an improved version of EPR insulation. The cable is resistant to heat, oil, moisture, and chemicals. Some of the typical uses of this cable include but are not limited to power plants, substations, and critical circuits. The operating temperature of the cable is 90°C. It is approved for installations in conduits and cable trays when supported by the messenger wire. Moreover, the cable is approved for direct burial. \u003c\/span\u003e \u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene is equally suitable for indoor and outdoor installations. Despite the fact that it is rugged, the cable is lightweight.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e267-16-2324 okonite, okonite cable, okonite wire, okonite instrument cable, instrumentation cable, instrument tray cable, direct burial cable, nuclear plant cable, control cable, okonite control cable, P-OS cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE Standard - 383 LOCA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eICEA S-73-532\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass 1E\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE 383 and 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass B tinned copper conductor. The pairs are color-coded in black and white, and the triads are color-coded in black, white, and red. The conductors are assembled with a left-hand lay, and fillers resistant to flames are placed in between.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N improved EPR insulation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe X-Olene FMR thermoset jacket.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe shielding is full-coverage copper-polyester-Nomex tape and a 7- coated tinned copper drain wire that reflects the size of the conductor.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cb\u003e\n\u003cli\u003eCatalog Number: ​​267-16-2324\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eAWG: 18\/7 strands\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNumber of Pairs: 24\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eJacket Thickness: 80 mil\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNominal Diameter: 1.46 inches\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eCross-sectional Area: 1.67 sq inches \u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNet Weight (lbs\/1000): 1014\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eShip Weight (lbs\/1000): 1120\u003c\/li\u003e\n\u003c\/b\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27562496786532,"sku":"NNC9290X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/okonite-fmr-n-x-olene-fmr_32_48b5c72a-f0ca-413d-a9d6-8736c455368c.jpg?v=1759805686"},{"product_id":"267-17-2301-okonite-fmr-n-x-olene-fmr-600-volt-instrumentation-cable-1-triad-overall-shield-type-p-os-18-awg","title":"267-17-2301 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable,  1 Triad - Overall Shield Type P-OS - 18 AWG","description":"[short]\n\u003cp\u003e\u003cstrong\u003eInsulation\u003cbr\u003e \u003c\/strong\u003e\u003cbr\u003e Okonite FMR-N is Okonite€™s trade name for its heat, moisture, flame and chemically resistant, mechanically rugged nuclear plant qualified ethylene-propylene insulation compound. Its physical properties and flame retardency permit its use without a jacket on the single conductors.\u003cbr\u003e The properties of Okonite FMR-N insulation substantially enhance the well known features of ethylene propylene rubber insulations.\u003cbr\u003e Nuclear qualified Okonite FMR-N cables meet IEEE Standard - 383 LOCA and flame test criteria.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e The overall jacket is a cross-linked polyethylene compound. This combination construction assures circuit security because of its high mechanical strength and excellent resistance to moisture, ozone, oil and many chemicals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOkonite FMR-N Instrumentation Cables are recommended for use in power generating plants and in substations; designed especially for critical circuits where continuity of service is of prime importance. This premium quality instrumentation cable is recommended for wet or dry, ac or dc service at conductor temperatures to 90°C. They may be installed in conduits, ducts, cable troughs, trays, messenger supported, or directly buried in the earth.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductors:\u003c\/strong\u003e Tinned copper per ASTM B-33, Class B stranded per ASTM B-8.\u003cbr\u003e \u003cstrong\u003eInsulation: \u003c\/strong\u003eOkonite FMR-N meets or exceeds the electrical and physical requirements of ICEA S-73-532\u003cbr\u003e \u003cstrong\u003eConductor Identification: \u003c\/strong\u003ePigmented black and white in pairs, black, white and red in triads; white conductor numerically printed for group identification. \u003cbr\u003e \u003cstrong\u003eAssembly: \u003c\/strong\u003ePairs or triads assembled with left-hand lay. Flame-retardant, non-wicking fillers included where required to provide a round cable.\u003cbr\u003e \u003cstrong\u003eCable Shield:\u003c\/strong\u003e Copper\/Polyester\/Nomex tape overlapped to provide 100% coverage, and a 7-strand tinned copper drain wire, same size as conductor.\u003cbr\u003e \u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e The X-Olene FMR compound meets or exceeds the requirements of thermoset jackets given in ICEA S-73-532.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eQualified as Class 1E cable\u003c\/li\u003e\n\u003cli\u003eFlame retardant - passes the IEEE 383 and 1202 flame test requirements.\u003c\/li\u003e\n\u003cli\u003eQuality Assurance traceability\u003c\/li\u003e\n\u003cli\u003e90°C rated control cable, factory assembled for indoor or outdoor installation in cable trays, in raceways, direct burial in the earth, or supported by messenger wire.\u003c\/li\u003e\n\u003cli\u003eMechanically rugged.\u003c\/li\u003e\n\u003cli\u003eColor coded conductors.\u003c\/li\u003e\n\u003cli\u003eResistant to water, oil and many chemicals.\u003c\/li\u003e\n\u003cli\u003eThermally stable at elevated temperatures.\u003c\/li\u003e\n\u003cli\u003eHigh insulation resistance, even at elevated temperatures.\u003c\/li\u003e\n\u003cli\u003eSmall diameter, lightweight.\u003c\/li\u003e\n\u003c\/ul\u003e\n[\/short]","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27562497015908,"sku":"NNC9291X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/okonite-fmr-n-x-olene-fmr_32_742ac86e-e47b-48d5-9b8d-abb40a5145c4.jpg?v=1762462567"},{"product_id":"267-17-2302-okonite-fmr-n-x-olene-fmr-600-volt-instrumentation-cable-2-triads-overall-shield-type-p-os-18-awg","title":"267-17-2302 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable,  2 Triads - Overall Shield Type P-OS - 18 AWG","description":"\u003ch2\u003e\u003cb\u003e267-17-2302 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable, 2 Triads - Overall Shield Type P-OS - 18 AWG\u003c\/b\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene FMR 600 Volt cable is a special cable used in nuclear plants. It is a flame-retardant and physically tough instrumentation cable with an improved version of EPR insulation. The cable is resistant to heat, oil, moisture, and chemicals. Some of the typical uses of this cable include but are not limited to power plants, substations, and critical circuits. The operating temperature of the cable is 90°C. It is approved for installations in conduits and cable trays when supported by the messenger wire. Moreover, the cable is approved for direct burial. \u003c\/span\u003e \u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene is equally suitable for indoor and outdoor installations. Despite the fact that it is rugged, the cable is lightweight.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e267-17-2302 okonite, okonite cable, okonite wire, okonite instrument cable, instrumentation cable, instrument tray cable, direct burial cable, nuclear plant cable, control cable, okonite control cable, P-OS cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE Standard - 383 LOCA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eICEA S-73-532\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass 1E\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE 383 and 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass B tinned copper conductor. The pairs are color-coded in black and white, and the triads are color-coded in black, white, and red. The conductors are assembled with a left-hand lay, and fillers resistant to flames are placed in between.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N improved EPR insulation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe X-Olene FMR thermoset jacket.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe shielding is full-coverage copper-polyester-Nomex tape and a 7- coated tinned copper drain wire that reflects the size of the conductor.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cb\u003e\n\u003cli\u003eCatalog Number: ​​267-17-2302\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eAWG: 18\/7 strands\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNumber of Triads: 2\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eJacket Thickness: 45 mil\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNominal Diameter: 0.45 inches\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eCross-sectional Area: 0.16 sq inches \u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNet Weight (lbs\/1000): 127\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eShip Weight (lbs\/1000): 150\u003c\/li\u003e\n\u003c\/b\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27562497278052,"sku":"NNC9292X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/okonite-fmr-n-x-olene-fmr_32_f5398a70-9fef-4f2f-9c03-cd4945571b49.jpg?v=1759805686"},{"product_id":"267-17-2304-okonite-fmr-n-x-olene-fmr-600-volt-instrumentation-cable-4-triads-overall-shield-type-p-os-18-awg","title":"267-17-2304 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable,  4 Triads - Overall Shield Type P-OS - 18 AWG","description":"\u003ch2\u003e\u003cb\u003e267-17-2304 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable, 4 Triads - Overall Shield Type P-OS - 18 AWG\u003c\/b\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene FMR 600 Volt cable is a special cable used in nuclear plants. It is a flame-retardant and physically tough instrumentation cable with an improved version of EPR insulation. The cable is resistant to heat, oil, moisture, and chemicals. Some of the typical uses of this cable include but are not limited to power plants, substations, and critical circuits. The operating temperature of the cable is 90°C. It is approved for installations in conduits and cable trays when supported by the messenger wire. Moreover, the cable is approved for direct burial. \u003c\/span\u003e \u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene is equally suitable for indoor and outdoor installations. Despite the fact that it is rugged, the cable is lightweight.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e267-17-2304 okonite, okonite cable, okonite wire, okonite instrument cable, instrumentation cable, instrument tray cable, direct burial cable, nuclear plant cable, control cable, okonite control cable, P-OS cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE Standard - 383 LOCA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eICEA S-73-532\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass 1E\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE 383 and 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass B tinned copper conductor. The pairs are color-coded in black and white, and the triads are color-coded in black, white, and red. The conductors are assembled with a left-hand lay, and fillers resistant to flames are placed in between.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N improved EPR insulation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe X-Olene FMR thermoset jacket.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe shielding is full-coverage copper-polyester-Nomex tape and a 7- coated tinned copper drain wire that reflects the size of the conductor.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cb\u003e\n\u003cli\u003eCatalog Number: ​​267-17-2304\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eAWG: 18\/7 strands\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNumber of Triads: 4\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eJacket Thickness: 60 mil\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNominal Diameter: 0.66 inches\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eCross-sectional Area: 0.34 sq inches \u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNet Weight (lbs\/1000): 223\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eShip Weight (lbs\/1000): 262\u003c\/li\u003e\n\u003c\/b\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27562497474660,"sku":"NNC9293X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/okonite-fmr-n-x-olene-fmr_32_951731d3-0e12-4aaa-b25b-cefdd5cc8960.jpg?v=1759805687"},{"product_id":"267-17-2308-okonite-fmr-n-x-olene-fmr-600-volt-instrumentation-cable-8-triads-overall-shield-type-p-os-18-awg","title":"267-17-2308 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable,  8 Triads - Overall Shield Type P-OS - 18 AWG","description":"\u003ch2\u003e\u003cb\u003e267-17-2308 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable, 8 Triads - Overall Shield Type P-OS - 18 AWG\u003c\/b\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene FMR 600 Volt cable is a special cable used in nuclear plants. It is a flame-retardant and physically tough instrumentation cable with an improved version of EPR insulation. The cable is resistant to heat, oil, moisture, and chemicals. Some of the typical uses of this cable include but are not limited to power plants, substations, and critical circuits. The operating temperature of the cable is 90°C. It is approved for installations in conduits and cable trays when supported by the messenger wire. Moreover, the cable is approved for direct burial. \u003c\/span\u003e \u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene is equally suitable for indoor and outdoor installations. Despite the fact that it is rugged, the cable is lightweight.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e267-17-2308 okonite, okonite cable, okonite wire, okonite instrument cable, instrumentation cable, instrument tray cable, direct burial cable, nuclear plant cable, control cable, okonite control cable, P-OS cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE Standard - 383 LOCA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eICEA S-73-532\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass 1E\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE 383 and 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass B tinned copper conductor. The pairs are color-coded in black and white, and the triads are color-coded in black, white, and red. The conductors are assembled with a left-hand lay, and fillers resistant to flames are placed in between.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N improved EPR insulation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe X-Olene FMR thermoset jacket.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe shielding is full-coverage copper-polyester-Nomex tape and a 7- coated tinned copper drain wire that reflects the size of the conductor.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cb\u003e\n\u003cli\u003eCatalog Number: ​​267-17-2308\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eAWG: 18\/7 strands\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNumber of Triads: 8\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eJacket Thickness: 60 mil\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNominal Diameter: 0.86 inches\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eCross-sectional Area: 0.58 sq inches \u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNet Weight (lbs\/1000): 352\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eShip Weight (lbs\/1000): 416\u003c\/li\u003e\n\u003c\/b\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27562498424932,"sku":"NNC9294X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/okonite-fmr-n-x-olene-fmr_32_64073b8e-256a-4c6a-ba50-d7a25fe719e0.jpg?v=1759805688"},{"product_id":"267-17-2312-okonite-fmr-n-x-olene-fmr-600-volt-instrumentation-cable-12-triads-overall-shield-type-p-os-18-awg","title":"267-17-2312 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable,  12 Triads - Overall Shield Type P-OS - 18 AWG","description":"\u003ch2\u003e\u003cb\u003e267-17-2312 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable, 12 Triads - Overall Shield Type P-OS - 18 AWG\u003c\/b\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene FMR 600 Volt cable is a special cable used in nuclear plants. It is a flame-retardant and physically tough instrumentation cable with an improved version of EPR insulation. The cable is resistant to heat, oil, moisture, and chemicals. Some of the typical uses of this cable include but are not limited to power plants, substations, and critical circuits. The operating temperature of the cable is 90°C. It is approved for installations in conduits and cable trays when supported by the messenger wire. Moreover, the cable is approved for direct burial. \u003c\/span\u003e \u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene is equally suitable for indoor and outdoor installations. Despite the fact that it is rugged, the cable is lightweight.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e267-17-2312 okonite, okonite cable, okonite wire, okonite instrument cable, instrumentation cable, instrument tray cable, direct burial cable, nuclear plant cable, control cable, okonite control cable, P-OS cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE Standard - 383 LOCA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eICEA S-73-532\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass 1E\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE 383 and 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass B tinned copper conductor. The pairs are color-coded in black and white, and the triads are color-coded in black, white, and red. The conductors are assembled with a left-hand lay, and fillers resistant to flames are placed in between.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N improved EPR insulation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe X-Olene FMR thermoset jacket.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe shielding is full-coverage copper-polyester-Nomex tape and a 7- coated tinned copper drain wire that reflects the size of the conductor.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cb\u003e\n\u003cli\u003eCatalog Number: ​​267-17-2312\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eAWG: 18\/7 strands\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNumber of Triads: 12\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eJacket Thickness: 80 mil\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNominal Diameter: 1.08 inches\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eCross-sectional Area: 0.92 sq inches \u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNet Weight (lbs\/1000): 527\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eShip Weight (lbs\/1000): 607\u003c\/li\u003e\n\u003c\/b\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27562498556004,"sku":"NNC9295X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/okonite-fmr-n-x-olene-fmr_32_20dae37a-cc60-4eca-9a1c-3ff8131dc12a.jpg?v=1762462570"},{"product_id":"267-17-2316-okonite-fmr-n-x-olene-fmr-600-volt-instrumentation-cable-16-triads-overall-shield-type-p-os-18-awg","title":"267-17-2316 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable,  16 Triads - Overall Shield Type P-OS - 18 AWG","description":"\u003ch2\u003e\u003cb\u003e267-17-2316 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable, 16 Triads - Overall Shield Type P-OS - 18 AWG\u003c\/b\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene FMR 600 Volt cable is a special cable used in nuclear plants. It is a flame-retardant and physically tough instrumentation cable with an improved version of EPR insulation. The cable is resistant to heat, oil, moisture, and chemicals. Some of the typical uses of this cable include but are not limited to power plants, substations, and critical circuits. The operating temperature of the cable is 90°C. It is approved for installations in conduits and cable trays when supported by the messenger wire. Moreover, the cable is approved for direct burial. \u003c\/span\u003e \u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene is equally suitable for indoor and outdoor installations. Despite the fact that it is rugged, the cable is lightweight.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e267-17-2316 okonite, okonite cable, okonite wire, okonite instrument cable, instrumentation cable, instrument tray cable, direct burial cable, nuclear plant cable, control cable, okonite control cable, P-OS cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE Standard - 383 LOCA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eICEA S-73-532\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass 1E\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE 383 and 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass B tinned copper conductor. The pairs are color-coded in black and white, and the triads are color-coded in black, white, and red. The conductors are assembled with a left-hand lay, and fillers resistant to flames are placed in between.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N improved EPR insulation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe X-Olene FMR thermoset jacket.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe shielding is full-coverage copper-polyester-Nomex tape and a 7- coated tinned copper drain wire that reflects the size of the conductor.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cb\u003e\n\u003cli\u003eCatalog Number: ​​267-17-2316\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eAWG: 18\/7 strands\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNumber of Triads: 16\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eJacket Thickness: 80 mil\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNominal Diameter: 1.20 inches\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eCross-sectional Area: 1.13 sq inches \u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNet Weight (lbs\/1000): 654\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eShip Weight (lbs\/1000): 734\u003c\/li\u003e\n\u003c\/b\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27562498752612,"sku":"NNC9296X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/okonite-fmr-n-x-olene-fmr_32_e7877d38-d159-41ca-8059-1bda13ef2657.jpg?v=1762462570"},{"product_id":"267-17-2320-okonite-fmr-n-x-olene-fmr-600-volt-instrumentation-cable-20-triads-overall-shield-type-p-os-18-awg","title":"267-17-2320 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable,  20 Triads - Overall Shield Type P-OS - 18 AWG","description":"\u003ch2\u003e\u003cb\u003e267-17-2320 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable, 20 Triads - Overall Shield Type P-OS - 18 AWG\u003c\/b\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene FMR 600 Volt cable is a special cable used in nuclear plants. It is a flame-retardant and physically tough instrumentation cable with an improved version of EPR insulation. The cable is resistant to heat, oil, moisture, and chemicals. Some of the typical uses of this cable include but are not limited to power plants, substations, and critical circuits. The operating temperature of the cable is 90°C. It is approved for installations in conduits and cable trays when supported by the messenger wire. Moreover, the cable is approved for direct burial. \u003c\/span\u003e \u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene is equally suitable for indoor and outdoor installations. Despite the fact that it is rugged, the cable is lightweight.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e267-17-2320 okonite, okonite cable, okonite wire, okonite instrument cable, instrumentation cable, instrument tray cable, direct burial cable, nuclear plant cable, control cable, okonite control cable, P-OS cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE Standard - 383 LOCA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eICEA S-73-532\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass 1E\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE 383 and 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass B tinned copper conductor. The pairs are color-coded in black and white, and the triads are color-coded in black, white, and red. The conductors are assembled with a left-hand lay, and fillers resistant to flames are placed in between.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N improved EPR insulation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe X-Olene FMR thermoset jacket.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe shielding is full-coverage copper-polyester-Nomex tape and a 7- coated tinned copper drain wire that reflects the size of the conductor.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cb\u003e\n\u003cli\u003eCatalog Number: ​​267-17-2320\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eAWG: 18\/7 strands\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNumber of Triads: 20\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eJacket Thickness: 80 mil\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNominal Diameter: 1.33 inches\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eCross-sectional Area: 1.39 sq inches \u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNet Weight (lbs\/1000): 826\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eShip Weight (lbs\/1000): 932\u003c\/li\u003e\n\u003c\/b\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27562498949220,"sku":"NNC9297X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/okonite-fmr-n-x-olene-fmr_32_985d1b00-2f41-465a-936a-c49545b6ec2a.jpg?v=1762462571"},{"product_id":"267-17-2324-okonite-fmr-n-x-olene-fmr-600-volt-instrumentation-cable-24-triads-overall-shield-type-p-os-18-awg","title":"267-17-2324 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable,  24 Triads - Overall Shield Type P-OS - 18 AWG","description":"\u003ch2\u003e\u003cb\u003e267-17-2324 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable, 24 Triads - Overall Shield Type P-OS - 18 AWG\u003c\/b\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene FMR 600 Volt cable is a special cable used in nuclear plants. It is a flame-retardant and physically tough instrumentation cable with an improved version of EPR insulation. The cable is resistant to heat, oil, moisture, and chemicals. Some of the typical uses of this cable include but are not limited to power plants, substations, and critical circuits. The operating temperature of the cable is 90°C. It is approved for installations in conduits and cable trays when supported by the messenger wire. Moreover, the cable is approved for direct burial. \u003c\/span\u003e \u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene is equally suitable for indoor and outdoor installations. Despite the fact that it is rugged, the cable is lightweight.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e267-17-2324 okonite, okonite cable, okonite wire, okonite instrument cable, instrumentation cable, instrument tray cable, direct burial cable, nuclear plant cable, control cable, okonite control cable, P-OS cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE Standard - 383 LOCA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eICEA S-73-532\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass 1E\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE 383 and 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass B tinned copper conductor. The pairs are color-coded in black and white, and the triads are color-coded in black, white, and red. The conductors are assembled with a left-hand lay, and fillers resistant to flames are placed in between.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N improved EPR insulation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe X-Olene FMR thermoset jacket.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe shielding is full-coverage copper-polyester-Nomex tape and a 7- coated tinned copper drain wire that reflects the size of the conductor.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cb\u003e\n\u003cli\u003eCatalog Number: ​​267-17-2324\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eAWG: 18\/7 strands\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNumber of Triads: 24\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eJacket Thickness: 80 mil\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNominal Diameter: 1.46 inches\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eCross-sectional Area: 1.67 sq inches \u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNet Weight (lbs\/1000): 1014\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eShip Weight (lbs\/1000): 1120\u003c\/li\u003e\n\u003c\/b\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27562499211364,"sku":"NNC9298X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/okonite-fmr-n-x-olene-fmr_32_1236fdee-213f-4d6e-9b67-7a1bd877eed2.jpg?v=1762462571"},{"product_id":"267-16-2401-okonite-fmr-n-x-olene-fmr-600-volt-instrumentation-cable-1-pair-overall-shield-type-p-os-16-awg","title":"267-16-2401 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable,  1 Pair - Overall Shield Type P-OS - 16 AWG","description":"\u003ch2\u003e\u003cb\u003e267-16-2401 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable, 1 Pair - Overall Shield Type P-OS - 16 AWG\u003c\/b\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene FMR 600 Volt cable is a special cable used in nuclear plants. It is a flame-retardant and physically tough instrumentation cable with an improved version of EPR insulation. The cable is resistant to heat, oil, moisture, and chemicals. Some of the typical uses of this cable include but are not limited to power plants, substations, and critical circuits. The operating temperature of the cable is 90°C. It is approved for installations in conduits and cable trays when supported by the messenger wire. Moreover, the cable is approved for direct burial. \u003c\/span\u003e \u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene is equally suitable for indoor and outdoor installations. Despite the fact that it is rugged, the cable is lightweight.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e267-17-2401 okonite, okonite cable, okonite wire, okonite instrument cable, instrumentation cable, instrument tray cable, direct burial cable, nuclear plant cable, control cable, okonite control cable, P-OS cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE Standard - 383 LOCA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eICEA S-73-532\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass 1E\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE 383 and 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass B tinned copper conductor. The pairs are color-coded in black and white, and the triads are color-coded in black, white, and red. The conductors are assembled with a left-hand lay, and fillers resistant to flames are placed in between.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N improved EPR insulation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe X-Olene FMR thermoset jacket.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe shielding is full-coverage copper-polyester-Nomex tape and a 7- coated tinned copper drain wire that reflects the size of the conductor.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cb\u003e\n\u003cli\u003eCatalog Number: ​​267-17-2401\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eAWG: 16\/7 strands\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNumber of Pairs: 1\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eJacket Thickness: 45 mil\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNominal Diameter: 0.33 inches\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eCross-sectional Area: 0.09 sq inches \u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNet Weight (lbs\/1000): 62\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eShip Weight (lbs\/1000): 73\u003c\/li\u003e\n\u003c\/b\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27562499407972,"sku":"NNC9299X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/okonite-fmr-n-x-olene-fmr_32_1c02998f-2acd-4f26-80ac-304188cfa6f5.jpg?v=1762462573"},{"product_id":"267-16-2402-okonite-fmr-n-x-olene-fmr-600-volt-instrumentation-cable-2-pairs-overall-shield-type-p-os-16-awg","title":"267-16-2402 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable,  2 Pairs - Overall Shield Type P-OS - 16 AWG","description":"\u003ch2\u003e\u003cb\u003e267-16-2402 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable, 2 Pairs - Overall Shield Type P-OS - 16 AWG\u003c\/b\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene FMR 600 Volt cable is a special cable used in nuclear plants. It is a flame-retardant and physically tough instrumentation cable with an improved version of EPR insulation. The cable is resistant to heat, oil, moisture, and chemicals. Some of the typical uses of this cable include but are not limited to power plants, substations, and critical circuits. The operating temperature of the cable is 90°C. It is approved for installations in conduits and cable trays when supported by the messenger wire. Moreover, the cable is approved for direct burial. \u003c\/span\u003e \u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene is equally suitable for indoor and outdoor installations. Despite the fact that it is rugged, the cable is lightweight.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e267-17-2402 okonite, okonite cable, okonite wire, okonite instrument cable, instrumentation cable, instrument tray cable, direct burial cable, nuclear plant cable, control cable, okonite control cable, P-OS cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE Standard - 383 LOCA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eICEA S-73-532\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass 1E\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE 383 and 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass B tinned copper conductor. The pairs are color-coded in black and white, and the triads are color-coded in black, white, and red. The conductors are assembled with a left-hand lay, and fillers resistant to flames are placed in between.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N improved EPR insulation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe X-Olene FMR thermoset jacket.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe shielding is full-coverage copper-polyester-Nomex tape and a 7- coated tinned copper drain wire that reflects the size of the conductor.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cb\u003e\n\u003cli\u003eCatalog Number: ​​267-17-2402\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eAWG: 16\/7 strands\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNumber of Pairs: 2\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eJacket Thickness: 45 mil\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNominal Diameter: 0.44 inches\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eCross-sectional Area: 0.15 sq inches \u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNet Weight (lbs\/1000): 125\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eShip Weight (lbs\/1000): 148\u003c\/li\u003e\n\u003c\/b\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27562499473508,"sku":"NNC9300X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/okonite-fmr-n-x-olene-fmr_32_b0cf489a-c14c-4e98-8f20-2a7218897138.jpg?v=1759805689"},{"product_id":"267-16-2404-okonite-fmr-n-x-olene-fmr-600-volt-instrumentation-cable-4-pairs-overall-shield-type-p-os-16-awg","title":"267-16-2404 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable,  4 Pairs - Overall Shield Type P-OS - 16 AWG","description":"\u003ch2\u003e\u003cb\u003e267-16-2404 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable, 4 Pairs - Overall Shield Type P-OS - 16 AWG\u003c\/b\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene FMR 600 Volt cable is a special cable used in nuclear plants. It is a flame-retardant and physically tough instrumentation cable with an improved version of EPR insulation. The cable is resistant to heat, oil, moisture, and chemicals. Some of the typical uses of this cable include but are not limited to power plants, substations, and critical circuits. The operating temperature of the cable is 90°C. It is approved for installations in conduits and cable trays when supported by the messenger wire. Moreover, the cable is approved for direct burial. \u003c\/span\u003e \u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene is equally suitable for indoor and outdoor installations. Despite the fact that it is rugged, the cable is lightweight.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e267-17-2404 okonite, okonite cable, okonite wire, okonite instrument cable, instrumentation cable, instrument tray cable, direct burial cable, nuclear plant cable, control cable, okonite control cable, P-OS cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE Standard - 383 LOCA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eICEA S-73-532\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass 1E\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE 383 and 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass B tinned copper conductor. The pairs are color-coded in black and white, and the triads are color-coded in black, white, and red. The conductors are assembled with a left-hand lay, and fillers resistant to flames are placed in between.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N improved EPR insulation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe X-Olene FMR thermoset jacket.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe shielding is full-coverage copper-polyester-Nomex tape and a 7- coated tinned copper drain wire that reflects the size of the conductor.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cb\u003e\n\u003cli\u003eCatalog Number: ​​267-17-2404\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eAWG: 16\/7 strands\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNumber of Pairs: 4\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eJacket Thickness: 60 mil\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNominal Diameter: 0.58 inches\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eCross-sectional Area: 0.26 sq inches \u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNet Weight (lbs\/1000): 208\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eShip Weight (lbs\/1000): 232\u003c\/li\u003e\n\u003c\/b\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27562499735652,"sku":"NNC9301X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/okonite-fmr-n-x-olene-fmr_32_623db5c4-3a0b-4b32-bc11-5382cf35790b.jpg?v=1762462574"},{"product_id":"267-16-2408-okonite-fmr-n-x-olene-fmr-600-volt-instrumentation-cable-8-pairs-overall-shield-type-p-os-16-awg","title":"267-16-2408 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable,  8 Pairs - Overall Shield Type P-OS - 16 AWG","description":"\u003ch2\u003e\u003cb\u003e267-16-2408 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable, 8 Pairs - Overall Shield Type P-OS - 16 AWG\u003c\/b\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene FMR 600 Volt cable is a special cable used in nuclear plants. It is a flame-retardant and physically tough instrumentation cable with an improved version of EPR insulation. The cable is resistant to heat, oil, moisture, and chemicals. Some of the typical uses of this cable include but are not limited to power plants, substations, and critical circuits. The operating temperature of the cable is 90°C. It is approved for installations in conduits and cable trays when supported by the messenger wire. Moreover, the cable is approved for direct burial. \u003c\/span\u003e \u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene is equally suitable for indoor and outdoor installations. Despite the fact that it is rugged, the cable is lightweight.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e267-17-2408 okonite, okonite cable, okonite wire, okonite instrument cable, instrumentation cable, instrument tray cable, direct burial cable, nuclear plant cable, control cable, okonite control cable, P-OS cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE Standard - 383 LOCA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eICEA S-73-532\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass 1E\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE 383 and 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass B tinned copper conductor. The pairs are color-coded in black and white, and the triads are color-coded in black, white, and red. The conductors are assembled with a left-hand lay, and fillers resistant to flames are placed in between.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N improved EPR insulation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe X-Olene FMR thermoset jacket.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe shielding is full-coverage copper-polyester-Nomex tape and a 7- coated tinned copper drain wire that reflects the size of the conductor.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cb\u003e\n\u003cli\u003eCatalog Number: ​​267-17-2408\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eAWG: 16\/7 strands\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNumber of Pairs: 4\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eJacket Thickness: 60 mil\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNominal Diameter: 0.77 inches\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eCross-sectional Area: 0.47 sq inches \u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNet Weight (lbs\/1000): 335\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eShip Weight (lbs\/1000): 374\u003c\/li\u003e\n\u003c\/b\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27562500063332,"sku":"NNC9302X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/okonite-fmr-n-x-olene-fmr_32_bafa826b-800e-4757-b738-7de8948c135f.jpg?v=1759805689"},{"product_id":"267-16-2412-okonite-fmr-n-x-olene-fmr-600-volt-instrumentation-cable-12-pairs-overall-shield-type-p-os-16-awg","title":"267-16-2412 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable,  12 Pairs - Overall Shield Type P-OS - 16 AWG","description":"\u003ch2\u003e\u003cb\u003e267-16-2412 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable, 12 Pairs - Overall Shield Type P-OS - 16 AWG\u003c\/b\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene FMR 600 Volt cable is a special cable used in nuclear plants. It is a flame-retardant and physically tough instrumentation cable with an improved version of EPR insulation. The cable is resistant to heat, oil, moisture, and chemicals. Some of the typical uses of this cable include but are not limited to power plants, substations, and critical circuits. The operating temperature of the cable is 90°C. It is approved for installations in conduits and cable trays when supported by the messenger wire. Moreover, the cable is approved for direct burial. \u003c\/span\u003e \u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene is equally suitable for indoor and outdoor installations. Despite the fact that it is rugged, the cable is lightweight.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e267-17-2412 okonite, okonite cable, okonite wire, okonite instrument cable, instrumentation cable, instrument tray cable, direct burial cable, nuclear plant cable, control cable, okonite control cable, P-OS cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE Standard - 383 LOCA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eICEA S-73-532\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass 1E\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE 383 and 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass B tinned copper conductor. The pairs are color-coded in black and white, and the triads are color-coded in black, white, and red. The conductors are assembled with a left-hand lay, and fillers resistant to flames are placed in between.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N improved EPR insulation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe X-Olene FMR thermoset jacket.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe shielding is full-coverage copper-polyester-Nomex tape and a 7- coated tinned copper drain wire that reflects the size of the conductor.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cb\u003e\n\u003cli\u003eCatalog Number: ​​267-17-2412\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eAWG: 16\/7 strands\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNumber of Pairs: 12\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eJacket Thickness: 80 mil\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNominal Diameter: 0.97 inches\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eCross-sectional Area: 0.74 sq inches \u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNet Weight (lbs\/1000): 492\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eShip Weight (lbs\/1000): 556\u003c\/li\u003e\n\u003c\/b\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27562500292708,"sku":"NNC9303X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/okonite-fmr-n-x-olene-fmr_32_a438da45-4b9e-4628-97db-6652e9c682cb.jpg?v=1762462575"},{"product_id":"267-16-2416-okonite-fmr-n-x-olene-fmr-600-volt-instrumentation-cable-16-pairs-overall-shield-type-p-os-16-awg","title":"267-16-2416 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable,  16 Pairs - Overall Shield Type P-OS - 16 AWG","description":"\u003ch2\u003e\u003cb\u003e267-16-2416 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable, 16 Pairs - Overall Shield Type P-OS - 16 AWG\u003c\/b\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene FMR 600 Volt cable is a special cable used in nuclear plants. It is a flame-retardant and physically tough instrumentation cable with an improved version of EPR insulation. The cable is resistant to heat, oil, moisture, and chemicals. Some of the typical uses of this cable include but are not limited to power plants, substations, and critical circuits. The operating temperature of the cable is 90°C. It is approved for installations in conduits and cable trays when supported by the messenger wire. Moreover, the cable is approved for direct burial. \u003c\/span\u003e \u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene is equally suitable for indoor and outdoor installations. Despite the fact that it is rugged, the cable is lightweight.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e267-17-2416 okonite, okonite cable, okonite wire, okonite instrument cable, instrumentation cable, instrument tray cable, direct burial cable, nuclear plant cable, control cable, okonite control cable, P-OS cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE Standard - 383 LOCA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eICEA S-73-532\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass 1E\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE 383 and 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass B tinned copper conductor. The pairs are color-coded in black and white, and the triads are color-coded in black, white, and red. The conductors are assembled with a left-hand lay, and fillers resistant to flames are placed in between.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N improved EPR insulation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe X-Olene FMR thermoset jacket.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe shielding is full-coverage copper-polyester-Nomex tape and a 7- coated tinned copper drain wire that reflects the size of the conductor.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cb\u003e\n\u003cli\u003eCatalog Number: ​​267-17-2416\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eAWG: 16\/7 strands\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNumber of Pairs: 16\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eJacket Thickness: 80 mil\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNominal Diameter: 1.05 inches\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eCross-sectional Area: 0.87 sq inches \u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNet Weight (lbs\/1000): 608\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eShip Weight (lbs\/1000): 668\u003c\/li\u003e\n\u003c\/b\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27562500391012,"sku":"NNC9304X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/okonite-fmr-n-x-olene-fmr_32_1562a09c-eeeb-4095-808c-7c64a5845fe5.jpg?v=1762462575"},{"product_id":"267-16-2420-okonite-fmr-n-x-olene-fmr-600-volt-instrumentation-cable-20-pairs-overall-shield-type-p-os-16-awg","title":"267-16-2420 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable,  20 Pairs - Overall Shield Type P-OS - 16 AWG","description":"\u003ch2\u003e\u003cb\u003e267-16-2420 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable, 20 Pairs - Overall Shield Type P-OS - 16 AWG\u003c\/b\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene FMR 600 Volt cable is a special cable used in nuclear plants. It is a flame-retardant and physically tough instrumentation cable with an improved version of EPR insulation. The cable is resistant to heat, oil, moisture, and chemicals. Some of the typical uses of this cable include but are not limited to power plants, substations, and critical circuits. The operating temperature of the cable is 90°C. It is approved for installations in conduits and cable trays when supported by the messenger wire. Moreover, the cable is approved for direct burial. \u003c\/span\u003e \u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene is equally suitable for indoor and outdoor installations. Despite the fact that it is rugged, the cable is lightweight.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e267-17-2420 okonite, okonite cable, okonite wire, okonite instrument cable, instrumentation cable, instrument tray cable, direct burial cable, nuclear plant cable, control cable, okonite control cable, P-OS cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE Standard - 383 LOCA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eICEA S-73-532\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass 1E\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE 383 and 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass B tinned copper conductor. The pairs are color-coded in black and white, and the triads are color-coded in black, white, and red. The conductors are assembled with a left-hand lay, and fillers resistant to flames are placed in between.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N improved EPR insulation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe X-Olene FMR thermoset jacket.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe shielding is full-coverage copper-polyester-Nomex tape and a 7- coated tinned copper drain wire that reflects the size of the conductor.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cb\u003e\n\u003cli\u003eCatalog Number: ​​267-17-2420\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eAWG: 16\/7 strands\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNumber of Triads: 20\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eJacket Thickness: 80 mil\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNominal Diameter: 1.47 inches\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eCross-sectional Area: 1.70 sq inches \u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNet Weight (lbs\/1000): 1098\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eShip Weight (lbs\/1000): 1204\u003c\/li\u003e\n\u003c\/b\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27562500587620,"sku":"NNC9305X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/okonite-fmr-n-x-olene-fmr_32_ef1c81f9-8175-49f9-904b-dce3a3b0b477.jpg?v=1759805690"},{"product_id":"267-16-2424-okonite-fmr-n-x-olene-fmr-600-volt-instrumentation-cable-24-pairs-overall-shield-type-p-os-16-awg","title":"267-16-2424 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable,  24 Pairs - Overall Shield Type P-OS - 16 AWG","description":"\u003ch2\u003e\u003cb\u003e267-16-2424 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable, 24 Pairs - Overall Shield Type P-OS - 16 AWG\u003c\/b\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene FMR 600 Volt cable is a special cable used in nuclear plants. It is a flame-retardant and physically tough instrumentation cable with an improved version of EPR insulation. The cable is resistant to heat, oil, moisture, and chemicals. Some of the typical uses of this cable include but are not limited to power plants, substations, and critical circuits. The operating temperature of the cable is 90°C. It is approved for installations in conduits and cable trays when supported by the messenger wire. Moreover, the cable is approved for direct burial. \u003c\/span\u003e \u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene is equally suitable for indoor and outdoor installations. Despite the fact that it is rugged, the cable is lightweight.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e267-17-2424 okonite, okonite cable, okonite wire, okonite instrument cable, instrumentation cable, instrument tray cable, direct burial cable, nuclear plant cable, control cable, okonite control cable, P-OS cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE Standard - 383 LOCA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eICEA S-73-532\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass 1E\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE 383 and 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass B tinned copper conductor. The pairs are color-coded in black and white, and the triads are color-coded in black, white, and red. The conductors are assembled with a left-hand lay, and fillers resistant to flames are placed in between.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N improved EPR insulation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe X-Olene FMR thermoset jacket.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe shielding is full-coverage copper-polyester-Nomex tape and a 7- coated tinned copper drain wire that reflects the size of the conductor.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cb\u003e\n\u003cli\u003eCatalog Number: ​​267-17-2424\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eAWG: 16\/7 strands\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNumber of Triads: 24\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eJacket Thickness: 80 mil\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNominal Diameter: 1.62 inches\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eCross-sectional Area: 2.06 sq inches \u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNet Weight (lbs\/1000): 1355\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eShip Weight (lbs\/1000): 1497\u003c\/li\u003e\n\u003c\/b\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27562500915300,"sku":"NNC9306X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/okonite-fmr-n-x-olene-fmr_32_f52674d4-d92d-46e5-95ad-7855f3717b63.jpg?v=1762462700"},{"product_id":"267-17-2401-okonite-fmr-n-x-olene-fmr-600-volt-instrumentation-cable-1-triad-overall-shield-type-p-os-16-awg","title":"267-17-2401 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable,  1 Triad - Overall Shield Type P-OS - 16 AWG","description":"\u003ch2\u003e\u003cb\u003e267-17-2401 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable, 1 Triad - Overall Shield Type P-OS - 16 AWG\u003c\/b\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene FMR 600 Volt cable is a special cable used in nuclear plants. It is a flame-retardant and physically tough instrumentation cable with an improved version of EPR insulation. The cable is resistant to heat, oil, moisture, and chemicals. Some of the typical uses of this cable include but are not limited to power plants, substations, and critical circuits. The operating temperature of the cable is 90°C. It is approved for installations in conduits and cable trays when supported by the messenger wire. Moreover, the cable is approved for direct burial. \u003c\/span\u003e \u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene is equally suitable for indoor and outdoor installations. Despite the fact that it is rugged, the cable is lightweight.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e267-17-2401 okonite, okonite cable, okonite wire, okonite instrument cable, instrumentation cable, instrument tray cable, direct burial cable, nuclear plant cable, control cable, okonite control cable, P-OS cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE Standard - 383 LOCA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eICEA S-73-532\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass 1E\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE 383 and 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass B tinned copper conductor. The pairs are color-coded in black and white, and the triads are color-coded in black, white, and red. The conductors are assembled with a left-hand lay, and fillers resistant to flames are placed in between.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N improved EPR insulation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe X-Olene FMR thermoset jacket.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe shielding is full-coverage copper-polyester-Nomex tape and a 7- coated tinned copper drain wire that reflects the size of the conductor.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cb\u003e\n\u003cli\u003eCatalog Number: ​​267-17-2401\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eAWG: 16\/7 strands\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNumber of Pairs: 1\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eJacket Thickness: 45 mil\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNominal Diameter: 0.35 inches\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eCross-sectional Area: 0.10 sq inches \u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNet Weight (lbs\/1000): 77\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eShip Weight (lbs\/1000): 98\u003c\/li\u003e\n\u003c\/b\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27562501144676,"sku":"NNC9307X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/okonite-fmr-n-x-olene-fmr_32_4c1880b0-710d-4072-aac7-d6b8a22b116f.jpg?v=1759805690"},{"product_id":"267-17-2402-okonite-fmr-n-x-olene-fmr-600-volt-instrumentation-cable-2-triads-overall-shield-type-p-os-16-awg","title":"267-17-2402 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable,  2 Triads - Overall Shield Type P-OS - 16 AWG","description":"\u003ch2\u003e\u003cb\u003e267-17-2402 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable, 2 Triads - Overall Shield Type P-OS - 16 AWG\u003c\/b\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene FMR 600 Volt cable is a special cable used in nuclear plants. It is a flame-retardant and physically tough instrumentation cable with an improved version of EPR insulation. The cable is resistant to heat, oil, moisture, and chemicals. Some of the typical uses of this cable include but are not limited to power plants, substations, and critical circuits. The operating temperature of the cable is 90°C. It is approved for installations in conduits and cable trays when supported by the messenger wire. Moreover, the cable is approved for direct burial. \u003c\/span\u003e \u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene is equally suitable for indoor and outdoor installations. Despite the fact that it is rugged, the cable is lightweight.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e267-17-2402 okonite, okonite cable, okonite wire, okonite instrument cable, instrumentation cable, instrument tray cable, direct burial cable, nuclear plant cable, control cable, okonite control cable, P-OS cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE Standard - 383 LOCA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eICEA S-73-532\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass 1E\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE 383 and 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass B tinned copper conductor. The pairs are color-coded in black and white, and the triads are color-coded in black, white, and red. The conductors are assembled with a left-hand lay, and fillers resistant to flames are placed in between.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N improved EPR insulation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe X-Olene FMR thermoset jacket.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe shielding is full-coverage copper-polyester-Nomex tape and a 7- coated tinned copper drain wire that reflects the size of the conductor.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cb\u003e\n\u003cli\u003eCatalog Number: ​​267-17-2402\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eAWG: 16\/7 strands\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNumber of Pairs: 2\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eJacket Thickness: 60 mil\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNominal Diameter: 0.63 inches\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eCross-sectional Area: 0.31 sq inches \u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNet Weight (lbs\/1000): 194\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eShip Weight (lbs\/1000): 218\u003c\/li\u003e\n\u003c\/b\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27562502127716,"sku":"NNC9308X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/okonite-fmr-n-x-olene-fmr_32_9579004b-3d6d-47c9-a9ca-ce56e2bb4afb.jpg?v=1759805692"},{"product_id":"267-17-2404-okonite-fmr-n-x-olene-fmr-600-volt-instrumentation-cable-4-triads-overall-shield-type-p-os-16-awg","title":"267-17-2404 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable,  4 Triads - Overall Shield Type P-OS - 16 AWG","description":"\u003ch2\u003e\u003cb\u003e267-17-2404 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable, 4 Triads - Overall Shield Type P-OS - 16 AWG\u003c\/b\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene FMR 600 Volt cable is a special cable used in nuclear plants. It is a flame-retardant and physically tough instrumentation cable with an improved version of EPR insulation. The cable is resistant to heat, oil, moisture, and chemicals. Some of the typical uses of this cable include but are not limited to power plants, substations, and critical circuits. The operating temperature of the cable is 90°C. It is approved for installations in conduits and cable trays when supported by the messenger wire. Moreover, the cable is approved for direct burial. \u003c\/span\u003e \u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene is equally suitable for indoor and outdoor installations. Despite the fact that it is rugged, the cable is lightweight.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e267-17-2404 okonite, okonite cable, okonite wire, okonite instrument cable, instrumentation cable, instrument tray cable, direct burial cable, nuclear plant cable, control cable, okonite control cable, P-OS cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE Standard - 383 LOCA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eICEA S-73-532\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass 1E\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE 383 and 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass B tinned copper conductor. The pairs are color-coded in black and white, and the triads are color-coded in black, white, and red. The conductors are assembled with a left-hand lay, and fillers resistant to flames are placed in between.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N improved EPR insulation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe X-Olene FMR thermoset jacket.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe shielding is full-coverage copper-polyester-Nomex tape and a 7- coated tinned copper drain wire that reflects the size of the conductor.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cb\u003e\n\u003cli\u003eCatalog Number: ​​267-17-2404\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eAWG: 16\/7 strands\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNumber of Triads: 4\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eJacket Thickness: 60 mil\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNominal Diameter: 0.73 inches\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eCross-sectional Area: 0.42 sq inches \u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNet Weight (lbs\/1000): 281\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eShip Weight (lbs\/1000): 319\u003c\/li\u003e\n\u003c\/b\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27562502258788,"sku":"NNC9309X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/okonite-fmr-n-x-olene-fmr_32_30db973c-6dc0-41f2-a404-629f36f2297f.jpg?v=1762462703"},{"product_id":"267-17-2408-okonite-fmr-n-x-olene-fmr-600-volt-instrumentation-cable-8-triads-overall-shield-type-p-os-16-awg","title":"267-17-2408 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable,  8 Triads - Overall Shield Type P-OS - 16 AWG","description":"\u003ch2\u003e\u003cb\u003e267-17-2408 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable, 8 Triads - Overall Shield Type P-OS - 16 AWG\u003c\/b\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene FMR 600 Volt cable is a special cable used in nuclear plants. It is a flame-retardant and physically tough instrumentation cable with an improved version of EPR insulation. The cable is resistant to heat, oil, moisture, and chemicals. Some of the typical uses of this cable include but are not limited to power plants, substations, and critical circuits. The operating temperature of the cable is 90°C. It is approved for installations in conduits and cable trays when supported by the messenger wire. Moreover, the cable is approved for direct burial. \u003c\/span\u003e \u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene is equally suitable for indoor and outdoor installations. Despite the fact that it is rugged, the cable is lightweight.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e267-17-2408 okonite, okonite cable, okonite wire, okonite instrument cable, instrumentation cable, instrument tray cable, direct burial cable, nuclear plant cable, control cable, okonite control cable, P-OS cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE Standard - 383 LOCA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eICEA S-73-532\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass 1E\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE 383 and 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass B tinned copper conductor. The pairs are color-coded in black and white, and the triads are color-coded in black, white, and red. The conductors are assembled with a left-hand lay, and fillers resistant to flames are placed in between.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N improved EPR insulation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe X-Olene FMR thermoset jacket.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe shielding is full-coverage copper-polyester-Nomex tape and a 7- coated tinned copper drain wire that reflects the size of the conductor.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cb\u003e\n\u003cli\u003eCatalog Number: ​​267-17-2408\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eAWG: 16\/7 strands\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNumber of Triads: 8\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eJacket Thickness: 80 mil\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNominal Diameter: 0.98 inches\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eCross-sectional Area: 0.75 sq inches \u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNet Weight (lbs\/1000): 503\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eShip Weight (lbs\/1000): 567\u003c\/li\u003e\n\u003c\/b\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27562502881380,"sku":"NNC9310X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/okonite-fmr-n-x-olene-fmr_32_aaf83c82-1c65-4731-a291-6fd111190c21.jpg?v=1762462703"},{"product_id":"267-17-2412-okonite-fmr-n-x-olene-fmr-600-volt-instrumentation-cable-12-triads-overall-shield-type-p-os-16-awg","title":"267-17-2412 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable,  12 Triads - Overall Shield Type P-OS - 16 AWG","description":"\u003ch2\u003e\u003cb\u003e267-17-2412 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable, 12 Triads - Overall Shield Type P-OS - 16 AWG\u003c\/b\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene FMR 600 Volt cable is a special cable used in nuclear plants. It is a flame-retardant and physically tough instrumentation cable with an improved version of EPR insulation. The cable is resistant to heat, oil, moisture, and chemicals. Some of the typical uses of this cable include but are not limited to power plants, substations, and critical circuits. The operating temperature of the cable is 90°C. It is approved for installations in conduits and cable trays when supported by the messenger wire. Moreover, the cable is approved for direct burial. \u003c\/span\u003e \u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene is equally suitable for indoor and outdoor installations. Despite the fact that it is rugged, the cable is lightweight.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e267-17-2412 okonite, okonite cable, okonite wire, okonite instrument cable, instrumentation cable, instrument tray cable, direct burial cable, nuclear plant cable, control cable, okonite control cable, P-OS cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE Standard - 383 LOCA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eICEA S-73-532\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass 1E\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE 383 and 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass B tinned copper conductor. The pairs are color-coded in black and white, and the triads are color-coded in black, white, and red. The conductors are assembled with a left-hand lay, and fillers resistant to flames are placed in between.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N improved EPR insulation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe X-Olene FMR thermoset jacket.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe shielding is full-coverage copper-polyester-Nomex tape and a 7- coated tinned copper drain wire that reflects the size of the conductor.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cb\u003e\n\u003cli\u003eCatalog Number: ​​267-17-2412\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eAWG: 16\/7 strands\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNumber of Triads: 12\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eJacket Thickness: 80 mil\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNominal Diameter: 1.19 inches\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eCross-sectional Area: 1.11 sq inches \u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNet Weight (lbs\/1000): 698\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eShip Weight (lbs\/1000): 778\u003c\/li\u003e\n\u003c\/b\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27562503143524,"sku":"NNC9311X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/okonite-fmr-n-x-olene-fmr_32_dff0fcdd-f00c-4cf7-8c2d-9272fb1a518b.jpg?v=1762462704"},{"product_id":"267-17-2416-okonite-fmr-n-x-olene-fmr-600-volt-instrumentation-cable-16-triads-overall-shield-type-p-os-16-awg","title":"267-17-2416 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable,  16 Triads - Overall Shield Type P-OS - 16 AWG","description":"\u003ch2\u003e\u003cb\u003e267-17-2416 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable, 16 Triads - Overall Shield Type P-OS - 16 AWG\u003c\/b\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene FMR 600 Volt cable is a special cable used in nuclear plants. It is a flame-retardant and physically tough instrumentation cable with an improved version of EPR insulation. The cable is resistant to heat, oil, moisture, and chemicals. Some of the typical uses of this cable include but are not limited to power plants, substations, and critical circuits. The operating temperature of the cable is 90°C. It is approved for installations in conduits and cable trays when supported by the messenger wire. Moreover, the cable is approved for direct burial. \u003c\/span\u003e \u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene is equally suitable for indoor and outdoor installations. Despite the fact that it is rugged, the cable is lightweight.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e267-17-2416 okonite, okonite cable, okonite wire, okonite instrument cable, instrumentation cable, instrument tray cable, direct burial cable, nuclear plant cable, control cable, okonite control cable, P-OS cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE Standard - 383 LOCA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eICEA S-73-532\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass 1E\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE 383 and 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass B tinned copper conductor. The pairs are color-coded in black and white, and the triads are color-coded in black, white, and red. The conductors are assembled with a left-hand lay, and fillers resistant to flames are placed in between.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N improved EPR insulation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe X-Olene FMR thermoset jacket.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe shielding is full-coverage copper-polyester-Nomex tape and a 7- coated tinned copper drain wire that reflects the size of the conductor.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cb\u003e\n\u003cli\u003eCatalog Number: ​​267-17-2416\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eAWG: 16\/7 strands\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNumber of Triads: 16\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eJacket Thickness: 80 mil\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNominal Diameter: 1.32 inches\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eCross-sectional Area: 1.37 sq inches \u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNet Weight (lbs\/1000): 870\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eShip Weight (lbs\/1000): 976\u003c\/li\u003e\n\u003c\/b\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27562503241828,"sku":"NNC9312X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/okonite-fmr-n-x-olene-fmr_32_4bb933a0-8896-4cf4-95fc-568b145f6789.jpg?v=1762462704"},{"product_id":"267-17-2420-okonite-fmr-n-x-olene-fmr-600-volt-instrumentation-cable-20-triads-overall-shield-type-p-os-16-awg","title":"267-17-2420 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable,  20 Triads - Overall Shield Type P-OS - 16 AWG","description":"\u003ch2\u003e\u003cb\u003e267-17-2420 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable, 20 Triads - Overall Shield Type P-OS - 16 AWG\u003c\/b\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene FMR 600 Volt cable is a special cable used in nuclear plants. It is a flame-retardant and physically tough instrumentation cable with an improved version of EPR insulation. The cable is resistant to heat, oil, moisture, and chemicals. Some of the typical uses of this cable include but are not limited to power plants, substations, and critical circuits. The operating temperature of the cable is 90°C. It is approved for installations in conduits and cable trays when supported by the messenger wire. Moreover, the cable is approved for direct burial. \u003c\/span\u003e \u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene is equally suitable for indoor and outdoor installations. Despite the fact that it is rugged, the cable is lightweight.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e267-17-2420 okonite, okonite cable, okonite wire, okonite instrument cable, instrumentation cable, instrument tray cable, direct burial cable, nuclear plant cable, control cable, okonite control cable, P-OS cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE Standard - 383 LOCA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eICEA S-73-532\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass 1E\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE 383 and 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass B tinned copper conductor. The pairs are color-coded in black and white, and the triads are color-coded in black, white, and red. The conductors are assembled with a left-hand lay, and fillers resistant to flames are placed in between.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N improved EPR insulation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe X-Olene FMR thermoset jacket.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe shielding is full-coverage copper-polyester-Nomex tape and a 7- coated tinned copper drain wire that reflects the size of the conductor.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cb\u003e\n\u003cli\u003eCatalog Number: ​​267-17-2420\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eAWG: 16\/7 strands\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNumber of Triads: 20\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eJacket Thickness: 80 mil\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNominal Diameter: 1.47 inches\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eCross-sectional Area: 1.70 sq inches \u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNet Weight (lbs\/1000): 1098\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eShip Weight (lbs\/1000): 1204\u003c\/li\u003e\n\u003c\/b\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27562503405668,"sku":"NNC9313X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/okonite-fmr-n-x-olene-fmr_32_63ac10b8-226c-4455-821b-60322d582de9.jpg?v=1762462706"},{"product_id":"267-17-2424-okonite-fmr-n-x-olene-fmr-600-volt-instrumentation-cable-24-triads-overall-shield-type-p-os-16-awg","title":"267-17-2424 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable,  24 Triads - Overall Shield Type P-OS - 16 AWG","description":"\u003ch2\u003e\u003cb\u003e267-17-2424 Okonite FMR-N X-Olene FMR 600 Volt Instrumentation Cable, 24 Triads - Overall Shield Type P-OS - 16 AWG\u003c\/b\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene FMR 600 Volt cable is a special cable used in nuclear plants. It is a flame-retardant and physically tough instrumentation cable with an improved version of EPR insulation. The cable is resistant to heat, oil, moisture, and chemicals. Some of the typical uses of this cable include but are not limited to power plants, substations, and critical circuits. The operating temperature of the cable is 90°C. It is approved for installations in conduits and cable trays when supported by the messenger wire. Moreover, the cable is approved for direct burial. \u003c\/span\u003e \u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N X-Olene is equally suitable for indoor and outdoor installations. Despite the fact that it is rugged, the cable is lightweight.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e267-17-2424 okonite, okonite cable, okonite wire, okonite instrument cable, instrumentation cable, instrument tray cable, direct burial cable, nuclear plant cable, control cable, okonite control cable, P-OS cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE Standard - 383 LOCA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eICEA S-73-532\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass 1E\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE 383 and 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass B tinned copper conductor. The pairs are color-coded in black and white, and the triads are color-coded in black, white, and red. The conductors are assembled with a left-hand lay, and fillers resistant to flames are placed in between.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOkonite FMR-N improved EPR insulation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe X-Olene FMR thermoset jacket.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eShielding:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe shielding is full-coverage copper-polyester-Nomex tape and a 7- coated tinned copper drain wire that reflects the size of the conductor.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cb\u003e\n\u003cli\u003eCatalog Number: ​​267-17-2424\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eAWG: 16\/7 strands\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNumber of Triads: 24\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eJacket Thickness: 80 mil\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNominal Diameter: 1.62 inches\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eCross-sectional Area: 2.06 sq inches \u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eNet Weight (lbs\/1000): 1355\u003c\/li\u003e\n\u003c\/b\u003e\u003cb\u003e\n\u003cli\u003eShip Weight (lbs\/1000): 1497\u003c\/li\u003e\n\u003c\/b\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27562503602276,"sku":"NNC9314X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/okonite-fmr-n-x-olene-fmr_32_df8157fc-b74b-4ddd-b112-7b8cf2b8dd65.jpg?v=1759805692"}],"url":"https:\/\/nassaunationalcable.com\/collections\/okonite-fmr-n-x-olene-fmr-600-volt-instrumentation-cable-pairs-or-triads-overall-shield-type-p-os-90-deg-c-rating.oembed?page=2","provider":"NassauNationalCable","version":"1.0","type":"link"}