{"title":"Multi Conductor Copper PE\/PVC Insulation PVC Jacket Control Cable","description":"","products":[{"product_id":"18-awg-12c-copper-pe-pvc-insulation-pvc-jacket-control-cable-600v","title":"18 AWG 12C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85013_1.pdf?v=1754982162\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e18 AWG 12C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Polyethylene and Polyvinyl Chloride (PE\/PVC) Insulation Polyvinyl Chloride (PVC) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e18 AWG 12C Multi conductor control cable, Copper control cable, PVC insulated control wire, PE insulation control cable, PVC jacket copper cable, Multi core copper control wire, Industrial control cable PVC, 18 AWG 12C Electrical multi conductor cable, Copper PVC sheathed control cable, 18 AWG 12C Flexible control cable PVC jacket.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA CSA marking is available upon request\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 1\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation:\u003cbr\u003e\u003c\/b\u003ePolyethylene (PE) 20 Mils thick and Polyvinyl Chloride (PVC) 10 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller:\u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder:\u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eRip Chord:\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket:\u003cbr\u003e\u003c\/b\u003ePolyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 18 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 12 \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.070\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 45\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e   0.511\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e 154\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 90\u003cbr\u003e\u003cstrong\u003e• DC Resistance Ω \/1000ft:  \u003c\/strong\u003e6.54\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C Ω \/1000ft: \u003c\/strong\u003e8.34\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 2.1\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e 6\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  6\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 6\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 325.114px; height: 35.5966px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e606790\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55715535946097,"sku":"NNC606790","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_dde84252-932f-408b-9bc2-3fc528015d56.png?v=1754982613"},{"product_id":"14-awg-2c-copper-pe-pvc-insulation-pvc-jacket-control-cable-600v","title":"14 AWG 2C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85013_1.pdf?v=1754982162\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 2C\u003c\/span\u003e\u003cspan data-sheets-root=\"1\"\u003e Copper \u003c\/span\u003e\u003cspan data-sheets-root=\"1\"\u003ePE\/PVC Insulation PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Polyethylene and Polyvinyl Chloride (PE\/PVC) Insulation Polyvinyl Chloride (PVC) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e14 AWG 2C Multi conductor control cable, Copper control cable, PVC insulated control wire, PE insulation control cable, PVC jacket copper cable, Multi core copper control wire, Industrial control cable PVC, 14 AWG 2C Electrical multi conductor cable, Copper PVC sheathed control cable, 14 AWG 2C Flexible control cable PVC jacket.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA CSA marking is available upon request\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 1\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation:\u003cbr\u003e\u003c\/b\u003ePolyethylene (PE) 20 Mils thick and Polyvinyl Chloride (PVC) 10 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller:\u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder:\u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eRip Chord:\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket:\u003cbr\u003e\u003c\/b\u003ePolyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 14 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 2\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.070\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 45\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e  0.349\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e 26\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 68\u003cbr\u003e\u003cstrong\u003e• DC Resistance Ω \/1000ft: \u003c\/strong\u003e 2.630\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C Ω \/1000ft: \u003c\/strong\u003e3.288\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 1.4\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e 15\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  15\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 15\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55715636281713,"sku":"NNC1022","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_dde84252-932f-408b-9bc2-3fc528015d56.png?v=1754982613"},{"product_id":"14-awg-3c-copper-pe-pvc-insulation-pvc-jacket-control-cable-600v","title":"14 AWG 3C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85013_1.pdf?v=1754982162\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 3C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Polyethylene and Polyvinyl Chloride (PE\/PVC) Insulation Polyvinyl Chloride (PVC) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e14 AWG 3C Multi conductor control cable, Copper control cable, PVC insulated control wire, PE insulation control cable, PVC jacket copper cable, Multi core copper control wire, Industrial control cable PVC, 14 AWG 3C Electrical multi conductor cable, Copper PVC sheathed control cable, 14 AWG 3C Flexible control cable PVC jacket.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA CSA marking is available upon request\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 1\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation:\u003cbr\u003e\u003c\/b\u003ePolyethylene (PE) 20 Mils thick and Polyvinyl Chloride (PVC) 10 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller:\u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder:\u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eRip Chord:\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket:\u003cbr\u003e\u003c\/b\u003ePolyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 14 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 3\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.070\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 45\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e  0.370\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e 38\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 87\u003cbr\u003e\u003cstrong\u003e• DC Resistance Ω \/1000ft:  \u003c\/strong\u003e2.630 \u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C Ω \/1000ft: \u003c\/strong\u003e3.288\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 1.5\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e 15\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  15\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 15\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55715943809393,"sku":"NNC1023","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_dde84252-932f-408b-9bc2-3fc528015d56.png?v=1754982613"},{"product_id":"14-awg-4c-copper-pe-pvc-insulation-pvc-jacket-control-cable-600v","title":"14 AWG 4C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85013_1.pdf?v=1754982162\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 4C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Polyethylene and Polyvinyl Chloride (PE\/PVC) Insulation Polyvinyl Chloride (PVC) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e14 AWG 4C Multi conductor control cable, Copper control cable, PVC insulated control wire, PE insulation control cable, PVC jacket copper cable, Multi core copper control wire, Industrial control cable PVC, 14 AWG 4C Electrical multi conductor cable, Copper PVC sheathed control cable, 14 AWG 4C Flexible control cable PVC jacket.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA CSA marking is available upon request\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 1\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation:\u003cbr\u003e\u003c\/b\u003ePolyethylene (PE) 20 Mils thick and Polyvinyl Chloride (PVC) 10 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller:\u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder:\u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eRip Chord:\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket:\u003cbr\u003e\u003c\/b\u003ePolyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 14 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 4\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.070\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 45\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e 0.403\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e 51\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 109\u003cbr\u003e\u003cstrong\u003e• DC Resistance Ω \/1000ft:  \u003c\/strong\u003e2.630 \u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C Ω \/1000ft: \u003c\/strong\u003e3.288\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 1.6\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e 14\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  15\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 15\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"width: 325.114px; height: 35.5966px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e620646\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"1000 FT","offer_id":55735631380849,"sku":"NNC620646","price":0.0,"currency_code":"USD","in_stock":true},{"title":"2000 FT","offer_id":55735631413617,"sku":"NNC620647","price":0.0,"currency_code":"USD","in_stock":true},{"title":"5000 FT","offer_id":55735631446385,"sku":"NNC620648","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_dde84252-932f-408b-9bc2-3fc528015d56.png?v=1754982613"},{"product_id":"14-awg-5c-copper-pe-pvc-insulation-pvc-jacket-control-cable-600v","title":"14 AWG 5C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85013_1.pdf?v=1754982162\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 5C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Polyethylene and Polyvinyl Chloride (PE\/PVC) Insulation Polyvinyl Chloride (PVC) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e14 AWG 5C Multi conductor control cable, Copper control cable, PVC insulated control wire, PE insulation control cable, PVC jacket copper cable, Multi core copper control wire, Industrial control cable PVC, 14 AWG 5C Electrical multi conductor cable, Copper PVC sheathed control cable, 14 AWG 5C Flexible control cable PVC jacket.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA CSA marking is available upon request\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 1\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation:\u003cbr\u003e\u003c\/b\u003ePolyethylene (PE) 20 Mils thick and Polyvinyl Chloride (PVC) 10 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller:\u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder:\u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eRip Chord:\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket:\u003cbr\u003e\u003c\/b\u003ePolyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 14 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 5\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.070\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 45\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e 0.440\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e 64\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 132\u003cbr\u003e\u003cstrong\u003e• DC Resistance Ω \/1000ft:  \u003c\/strong\u003e2.630 \u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C Ω \/1000ft: \u003c\/strong\u003e3.288\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 1.8\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e 14\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  15\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 15\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55715965960561,"sku":"NNC1124","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_dde84252-932f-408b-9bc2-3fc528015d56.png?v=1754982613"},{"product_id":"14-awg-6c-copper-pe-pvc-insulation-pvc-jacket-control-cable-600v","title":"14 AWG 6C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85013_1.pdf?v=1754982162\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 5C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Polyethylene and Polyvinyl Chloride (PE\/PVC) Insulation Polyvinyl Chloride (PVC) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e14 AWG 5C Multi conductor control cable, Copper control cable, PVC insulated control wire, PE insulation control cable, PVC jacket copper cable, Multi core copper control wire, Industrial control cable PVC, 14 AWG 5C Electrical multi conductor cable, Copper PVC sheathed control cable, 14 AWG 5C Flexible control cable PVC jacket.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA CSA marking is available upon request\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 1\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation:\u003cbr\u003e\u003c\/b\u003ePolyethylene (PE) 20 Mils thick and Polyvinyl Chloride (PVC) 10 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller:\u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder:\u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eRip Chord:\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket:\u003cbr\u003e\u003c\/b\u003ePolyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 14 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 5\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.070\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 45\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e 0.440\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e 64\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 132\u003cbr\u003e\u003cstrong\u003e• DC Resistance Ω \/1000ft:  \u003c\/strong\u003e2.630 \u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C Ω \/1000ft: \u003c\/strong\u003e3.288\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 1.8\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e 14\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  15\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 15\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55715967828337,"sku":"NNC1024","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_dde84252-932f-408b-9bc2-3fc528015d56.png?v=1754982613"},{"product_id":"14-awg-6c-copper-pe-pvc-insulation-pvc-jacket-control-cable-600v-1","title":"14 AWG 6C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85013_1.pdf?v=1754982162\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 6C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Polyethylene and Polyvinyl Chloride (PE\/PVC) Insulation Polyvinyl Chloride (PVC) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e14 AWG 6C Multi conductor control cable, Copper control cable, PVC insulated control wire, PE insulation control cable, PVC jacket copper cable, Multi core copper control wire, Industrial control cable PVC, 14 AWG 6C Electrical multi conductor cable, Copper PVC sheathed control cable, 14 AWG 6C Flexible control cable PVC jacket.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA CSA marking is available upon request\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 1\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation:\u003cbr\u003e\u003c\/b\u003ePolyethylene (PE) 20 Mils thick and Polyvinyl Chloride (PVC) 10 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller:\u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder:\u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eRip Chord:\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket:\u003cbr\u003e\u003c\/b\u003ePolyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 14 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 6\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.070\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 45\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e 0.479\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e77\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  155\u003cbr\u003e\u003cstrong\u003e• DC Resistance Ω \/1000ft:  \u003c\/strong\u003e2.630 \u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C Ω \/1000ft: \u003c\/strong\u003e3.288\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 1.9\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e 14\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  15\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 15\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55715970679153,"sku":"NNC1125","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_dde84252-932f-408b-9bc2-3fc528015d56.png?v=1754982613"},{"product_id":"14-awg-7c-copper-pe-pvc-insulation-pvc-jacket-control-cable-600v","title":"14 AWG 7C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85013_1.pdf?v=1754982162\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 7C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Polyethylene and Polyvinyl Chloride (PE\/PVC) Insulation Polyvinyl Chloride (PVC) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e14 AWG 7C Multi conductor control cable, Copper control cable, PVC insulated control wire, PE insulation control cable, PVC jacket copper cable, Multi core copper control wire, Industrial control cable PVC, 14 AWG 7C Electrical multi conductor cable, Copper PVC sheathed control cable, 14 AWG 7C Flexible control cable PVC jacket.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA CSA marking is available upon request\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 1\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation:\u003cbr\u003e\u003c\/b\u003ePolyethylene (PE) 20 Mils thick and Polyvinyl Chloride (PVC) 10 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller:\u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder:\u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eRip Chord:\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket:\u003cbr\u003e\u003c\/b\u003ePolyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 14 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 7\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.070\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 45\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e 0.479\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 90\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 171\u003cbr\u003e\u003cstrong\u003e• DC Resistance Ω \/1000ft:  \u003c\/strong\u003e2.630 \u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C Ω \/1000ft: \u003c\/strong\u003e3.288\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 1.9\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e 12\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  15\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 15\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"width: 325.114px; height: 35.5966px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e606776\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"1000 FT","offer_id":55735633019249,"sku":"NNC606776","price":0.0,"currency_code":"USD","in_stock":true},{"title":"2500 FT","offer_id":55735633052017,"sku":"NNC606777","price":0.0,"currency_code":"USD","in_stock":true},{"title":"5000 FT","offer_id":55735633084785,"sku":"NNC606778","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_dde84252-932f-408b-9bc2-3fc528015d56.png?v=1754982613"},{"product_id":"14-awg-8c-copper-pe-pvc-insulation-pvc-jacket-control-cable-600v","title":"14 AWG 8C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85013_1.pdf?v=1754982162\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 8C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Polyethylene and Polyvinyl Chloride (PE\/PVC) Insulation Polyvinyl Chloride (PVC) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e14 AWG 8C Multi conductor control cable, Copper control cable, PVC insulated control wire, PE insulation control cable, PVC jacket copper cable, Multi core copper control wire, Industrial control cable PVC, 14 AWG 8C Electrical multi conductor cable, Copper PVC sheathed control cable, 14 AWG 8C Flexible control cable PVC jacket.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA CSA marking is available upon request\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 1\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation:\u003cbr\u003e\u003c\/b\u003ePolyethylene (PE) 20 Mils thick and Polyvinyl Chloride (PVC) 10 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller:\u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder:\u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eRip Chord:\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket:\u003cbr\u003e\u003c\/b\u003ePolyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 14 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 8\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.070\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 45\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e 0.519\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 102\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  195\u003cbr\u003e\u003cstrong\u003e• DC Resistance Ω \/1000ft:  \u003c\/strong\u003e2.630 \u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C Ω \/1000ft: \u003c\/strong\u003e3.288\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 2.1\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e 12\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  15\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 15\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55715974349169,"sku":"NNC1127","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_dde84252-932f-408b-9bc2-3fc528015d56.png?v=1754982613"},{"product_id":"14-awg-9c-copper-pe-pvc-insulation-pvc-jacket-control-cable-600v","title":"14 AWG 9C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85013_1.pdf?v=1754982162\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 9C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Polyethylene and Polyvinyl Chloride (PE\/PVC) Insulation Polyvinyl Chloride (PVC) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e14 AWG 9C Multi conductor control cable, Copper control cable, PVC insulated control wire, PE insulation control cable, PVC jacket copper cable, Multi core copper control wire, Industrial control cable PVC, 14 AWG 9C Electrical multi conductor cable, Copper PVC sheathed control cable, 14 AWG 9C Flexible control cable PVC jacket.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA CSA marking is available upon request\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 1\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation:\u003cbr\u003e\u003c\/b\u003ePolyethylene (PE) 20 Mils thick and Polyvinyl Chloride (PVC) 10 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller:\u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder:\u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eRip Chord:\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket:\u003cbr\u003e\u003c\/b\u003ePolyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 14 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 9\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.070\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 60\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e 0.588\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 115\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  236\u003cbr\u003e\u003cstrong\u003e• DC Resistance Ω \/1000ft:  \u003c\/strong\u003e2.630 \u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C Ω \/1000ft: \u003c\/strong\u003e3.288\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 2.4\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e 12\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  15\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 15\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55715978281329,"sku":"NNC1128","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_dde84252-932f-408b-9bc2-3fc528015d56.png?v=1754982613"},{"product_id":"14-awg-10c-copper-pe-pvc-insulation-pvc-jacket-control-cable-600v","title":"14 AWG 10C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85013_1.pdf?v=1754982162\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 10C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Polyethylene and Polyvinyl Chloride (PE\/PVC) Insulation Polyvinyl Chloride (PVC) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e14 AWG 10C Multi conductor control cable, Copper control cable, PVC insulated control wire, PE insulation control cable, PVC jacket copper cable, Multi core copper control wire, Industrial control cable PVC, 14 AWG 10C Electrical multi conductor cable, Copper PVC sheathed control cable, 14 AWG 10C Flexible control cable PVC jacket.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA CSA marking is available upon request\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 1\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation:\u003cbr\u003e\u003c\/b\u003ePolyethylene (PE) 20 Mils thick and Polyvinyl Chloride (PVC) 10 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller:\u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder:\u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eRip Chord:\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket:\u003cbr\u003e\u003c\/b\u003ePolyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 14 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 10\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.070\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 60\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e  0.638\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 128\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  266\u003cbr\u003e\u003cstrong\u003e• DC Resistance Ω \/1000ft:  \u003c\/strong\u003e2.630 \u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C Ω \/1000ft: \u003c\/strong\u003e3.288\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 2.6\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e 9\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 11\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 12\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55715988111729,"sku":"NNC1129","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_dde84252-932f-408b-9bc2-3fc528015d56.png?v=1754982613"},{"product_id":"14-awg-12c-copper-pe-pvc-insulation-pvc-jacket-control-cable-600v","title":"14 AWG 12C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85013_1.pdf?v=1754982162\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 12C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Polyethylene and Polyvinyl Chloride (PE\/PVC) Insulation Polyvinyl Chloride (PVC) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e14 AWG 12C Multi conductor control cable, Copper control cable, PVC insulated control wire, PE insulation control cable, PVC jacket copper cable, Multi core copper control wire, Industrial control cable PVC, 14 AWG 12C Electrical multi conductor cable, Copper PVC sheathed control cable, 14 AWG 12C Flexible control cable PVC jacket.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA CSA marking is available upon request\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 1\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation:\u003cbr\u003e\u003c\/b\u003ePolyethylene (PE) 20 Mils thick and Polyvinyl Chloride (PVC) 10 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller:\u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder:\u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eRip Chord:\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket:\u003cbr\u003e\u003c\/b\u003ePolyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 14 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 12\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.070\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 60\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e   0.659\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 154\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  303\u003cbr\u003e\u003cstrong\u003e• DC Resistance Ω \/1000ft:  \u003c\/strong\u003e2.630 \u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C Ω \/1000ft: \u003c\/strong\u003e3.288\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 2.6\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e 9\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 11\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 12\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"width: 325.114px; height: 35.5966px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e606777\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"1000 FT","offer_id":55735635247473,"sku":"NNC606777","price":0.0,"currency_code":"USD","in_stock":true},{"title":"2500 FT","offer_id":55735635280241,"sku":"NNC606778","price":0.0,"currency_code":"USD","in_stock":true},{"title":"5000 FT","offer_id":55735635313009,"sku":"NNC606779","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_dde84252-932f-408b-9bc2-3fc528015d56.png?v=1754982613"},{"product_id":"14-awg-15c-copper-pe-pvc-insulation-pvc-jacket-control-cable-600v","title":"14 AWG 15C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85013_1.pdf?v=1754982162\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 15C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Polyethylene and Polyvinyl Chloride (PE\/PVC) Insulation Polyvinyl Chloride (PVC) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e14 AWG 15C Multi conductor control cable, Copper control cable, PVC insulated control wire, PE insulation control cable, PVC jacket copper cable, Multi core copper control wire, Industrial control cable PVC, 14 AWG 15C Electrical multi conductor cable, Copper PVC sheathed control cable, 14 AWG 15C Flexible control cable PVC jacket.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA CSA marking is available upon request\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 1\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation:\u003cbr\u003e\u003c\/b\u003ePolyethylene (PE) 20 Mils thick and Polyvinyl Chloride (PVC) 10 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller:\u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder:\u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eRip Chord:\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket:\u003cbr\u003e\u003c\/b\u003ePolyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 14 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 15\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.070\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 60\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e  0.730\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 192\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  371\u003cbr\u003e\u003cstrong\u003e• DC Resistance Ω \/1000ft:  \u003c\/strong\u003e2.630 \u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C Ω \/1000ft: \u003c\/strong\u003e3.288\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 2.9\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e 9\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 11\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 12\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55715992306033,"sku":"NNC1130","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_dde84252-932f-408b-9bc2-3fc528015d56.png?v=1754982613"},{"product_id":"14-awg-19c-copper-pe-pvc-insulation-pvc-jacket-control-cable-600v","title":"14 AWG 19C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85013_1.pdf?v=1754982162\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 19C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Polyethylene and Polyvinyl Chloride (PE\/PVC) Insulation Polyvinyl Chloride (PVC) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e14 AWG 19C Multi conductor control cable, Copper control cable, PVC insulated control wire, PE insulation control cable, PVC jacket copper cable, Multi core copper control wire, Industrial control cable PVC, 14 AWG 19C Electrical multi conductor cable, Copper PVC sheathed control cable, 14 AWG 19C Flexible control cable PVC jacket.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA CSA marking is available upon request\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 1\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation:\u003cbr\u003e\u003c\/b\u003ePolyethylene (PE) 20 Mils thick and Polyvinyl Chloride (PVC) 10 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller:\u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder:\u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eRip Chord:\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket:\u003cbr\u003e\u003c\/b\u003ePolyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 14 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.070\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 60\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e  0.768\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 243\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 446\u003cbr\u003e\u003cstrong\u003e• DC Resistance Ω \/1000ft:  \u003c\/strong\u003e2.630 \u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C Ω \/1000ft: \u003c\/strong\u003e3.288\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 3.1\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e 9\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 11\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 12\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55715993026929,"sku":"NNC1131","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_dde84252-932f-408b-9bc2-3fc528015d56.png?v=1754982613"},{"product_id":"14-awg-20c-copper-pe-pvc-insulation-pvc-jacket-control-cable-600v","title":"14 AWG 20C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85013_1.pdf?v=1754982162\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 20C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Polyethylene and Polyvinyl Chloride (PE\/PVC) Insulation Polyvinyl Chloride (PVC) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e14 AWG 20C Multi conductor control cable, Copper control cable, PVC insulated control wire, PE insulation control cable, PVC jacket copper cable, Multi core copper control wire, Industrial control cable PVC, 14 AWG 20C Electrical multi conductor cable, Copper PVC sheathed control cable, 14 AWG 20C Flexible control cable PVC jacket.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA CSA marking is available upon request\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 1\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation:\u003cbr\u003e\u003c\/b\u003ePolyethylene (PE) 20 Mils thick and Polyvinyl Chloride (PVC) 10 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller:\u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder:\u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eRip Chord:\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket:\u003cbr\u003e\u003c\/b\u003ePolyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 14 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 20\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.070\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 60\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e  0.808\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  256\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 475\u003cbr\u003e\u003cstrong\u003e• DC Resistance Ω \/1000ft:  \u003c\/strong\u003e2.630 \u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C Ω \/1000ft: \u003c\/strong\u003e3.288\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 3.2\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e 9\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 11\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 12\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55715994829169,"sku":"NNC1132","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_dde84252-932f-408b-9bc2-3fc528015d56.png?v=1754982613"},{"product_id":"14-awg-25c-copper-pe-pvc-insulation-pvc-jacket-control-cable-600v","title":"14 AWG 25C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85013_1.pdf?v=1754982162\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 25C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Polyethylene and Polyvinyl Chloride (PE\/PVC) Insulation Polyvinyl Chloride (PVC) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e14 AWG 25C Multi conductor control cable, Copper control cable, PVC insulated control wire, PE insulation control cable, PVC jacket copper cable, Multi core copper control wire, Industrial control cable PVC, 14 AWG 25C Electrical multi conductor cable, Copper PVC sheathed control cable, 14 AWG 25C Flexible control cable PVC jacket.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA CSA marking is available upon request\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 1\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation:\u003cbr\u003e\u003c\/b\u003ePolyethylene (PE) 20 Mils thick and Polyvinyl Chloride (PVC) 10 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller:\u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder:\u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eRip Chord:\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket:\u003cbr\u003e\u003c\/b\u003ePolyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 14 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 25\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.070\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e   0.937\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 320\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  619\u003cbr\u003e\u003cstrong\u003e• DC Resistance Ω \/1000ft:  \u003c\/strong\u003e2.630 \u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C Ω \/1000ft: \u003c\/strong\u003e3.288\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 3.7\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 8\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 9\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 11\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55715996238193,"sku":"NNC1133","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_dde84252-932f-408b-9bc2-3fc528015d56.png?v=1754982613"},{"product_id":"14-awg-30c-copper-pe-pvc-insulation-pvc-jacket-control-cable-600v","title":"14 AWG 30C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85013_1.pdf?v=1754982162\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 30C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Polyethylene and Polyvinyl Chloride (PE\/PVC) Insulation Polyvinyl Chloride (PVC) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e14 AWG 30C Multi conductor control cable, Copper control cable, PVC insulated control wire, PE insulation control cable, PVC jacket copper cable, Multi core copper control wire, Industrial control cable PVC, 14 AWG 30C Electrical multi conductor cable, Copper PVC sheathed control cable, 14 AWG 30C Flexible control cable PVC jacket.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA CSA marking is available upon request\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 1\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation:\u003cbr\u003e\u003c\/b\u003ePolyethylene (PE) 20 Mils thick and Polyvinyl Chloride (PVC) 10 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller:\u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder:\u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eRip Chord:\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket:\u003cbr\u003e\u003c\/b\u003ePolyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 14 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.070\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e  0.991\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  384\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 719\u003cbr\u003e\u003cstrong\u003e• DC Resistance Ω \/1000ft:  \u003c\/strong\u003e2.630 \u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C Ω \/1000ft: \u003c\/strong\u003e3.288\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 4.0\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 8\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 9\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 11\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55715996533105,"sku":"NNC1134","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_dde84252-932f-408b-9bc2-3fc528015d56.png?v=1754982613"},{"product_id":"14-awg-37c-copper-pe-pvc-insulation-pvc-jacket-control-cable-600v","title":"14 AWG 37C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85013_1.pdf?v=1754982162\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 37C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Polyethylene and Polyvinyl Chloride (PE\/PVC) Insulation Polyvinyl Chloride (PVC) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e14 AWG 37C Multi conductor control cable, Copper control cable, PVC insulated control wire, PE insulation control cable, PVC jacket copper cable, Multi core copper control wire, Industrial control cable PVC, 14 AWG 37C Electrical multi conductor cable, Copper PVC sheathed control cable, 14 AWG 37C Flexible control cable PVC jacket.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA CSA marking is available upon request\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 1\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation:\u003cbr\u003e\u003c\/b\u003ePolyethylene (PE) 20 Mils thick and Polyvinyl Chloride (PVC) 10 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller:\u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder:\u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eRip Chord:\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket:\u003cbr\u003e\u003c\/b\u003ePolyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 14 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 37\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.070\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e 1.067\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  474\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  862\u003cbr\u003e\u003cstrong\u003e• DC Resistance Ω \/1000ft:  \u003c\/strong\u003e2.630 \u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C Ω \/1000ft: \u003c\/strong\u003e3.288\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 5.3\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  7\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 8\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 10\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55715997188465,"sku":"NNC1135","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_dde84252-932f-408b-9bc2-3fc528015d56.png?v=1754982613"},{"product_id":"12-awg-2c-copper-pe-pvc-insulation-pvc-jacket-control-cable-600v","title":"12 AWG 2C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85013_1.pdf?v=1754982162\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 2C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Polyethylene and Polyvinyl Chloride (PE\/PVC) Insulation Polyvinyl Chloride (PVC) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e12 AWG 2C Multi conductor control cable, Copper control cable, PVC insulated control wire, PE insulation control cable, PVC jacket copper cable, Multi core copper control wire, Industrial control cable PVC, 12 AWG 2C Electrical multi conductor cable, Copper PVC sheathed control cable, 12 AWG 2C Flexible control cable PVC jacket.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA CSA marking is available upon request\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 1\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation:\u003cbr\u003e\u003c\/b\u003ePolyethylene (PE) 20 Mils thick and Polyvinyl Chloride (PVC) 10 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller:\u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder:\u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eRip Chord:\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket:\u003cbr\u003e\u003c\/b\u003ePolyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 12 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 2\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.087\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 45\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e  0.384\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  41\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  90\u003cbr\u003e\u003cstrong\u003e• DC Resistance Ω \/1000ft: \u003c\/strong\u003e 1.660 \u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C Ω \/1000ft:\u003c\/strong\u003e 2.075\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 1.5\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  20\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  20\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  20\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"width: 325.114px; height: 35.5966px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e618721\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55715997417841,"sku":"NNC618721","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_dde84252-932f-408b-9bc2-3fc528015d56.png?v=1754982613"},{"product_id":"12-awg-3c-copper-pe-pvc-insulation-pvc-jacket-control-cable-600v","title":"12 AWG 3C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85013_1.pdf?v=1754982162\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 3C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Polyethylene and Polyvinyl Chloride (PE\/PVC) Insulation Polyvinyl Chloride (PVC) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e12 AWG 3C Multi conductor control cable, Copper control cable, PVC insulated control wire, PE insulation control cable, PVC jacket copper cable, Multi core copper control wire, Industrial control cable PVC, 12 AWG 3C Electrical multi conductor cable, Copper PVC sheathed control cable, 12 AWG 3C Flexible control cable PVC jacket.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA CSA marking is available upon request\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 1\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation:\u003cbr\u003e\u003c\/b\u003ePolyethylene (PE) 20 Mils thick and Polyvinyl Chloride (PVC) 10 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller:\u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder:\u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eRip Chord:\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket:\u003cbr\u003e\u003c\/b\u003ePolyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 12 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 3\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.087\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 45\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e  0.408\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  61\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  118\u003cbr\u003e\u003cstrong\u003e• DC Resistance Ω \/1000ft: \u003c\/strong\u003e 1.660 \u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C Ω \/1000ft:\u003c\/strong\u003e 2.075\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 1.6\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  20\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  20\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  20\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55715998204273,"sku":"NNC1136","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_dde84252-932f-408b-9bc2-3fc528015d56.png?v=1754982613"},{"product_id":"12-awg-4c-copper-pe-pvc-insulation-pvc-jacket-control-cable-600v","title":"12 AWG 4C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85013_1.pdf?v=1754982162\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 4C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Polyethylene and Polyvinyl Chloride (PE\/PVC) Insulation Polyvinyl Chloride (PVC) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e12 AWG 4C Multi conductor control cable, Copper control cable, PVC insulated control wire, PE insulation control cable, PVC jacket copper cable, Multi core copper control wire, Industrial control cable PVC, 12 AWG 4C Electrical multi conductor cable, Copper PVC sheathed control cable, 12 AWG 4C Flexible control cable PVC jacket.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA CSA marking is available upon request\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 1\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation:\u003cbr\u003e\u003c\/b\u003ePolyethylene (PE) 20 Mils thick and Polyvinyl Chloride (PVC) 10 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller:\u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder:\u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eRip Chord:\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket:\u003cbr\u003e\u003c\/b\u003ePolyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 12 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 4\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.087\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 45\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e  0.445\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e   81\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  148\u003cbr\u003e\u003cstrong\u003e• DC Resistance Ω \/1000ft: \u003c\/strong\u003e 1.660 \u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C Ω \/1000ft:\u003c\/strong\u003e 2.075\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 1.8\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  16\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  20\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  20\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"width: 325.114px; height: 35.5966px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e616856\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"1000 FT","offer_id":55740143960433,"sku":"NNC616856","price":0.0,"currency_code":"USD","in_stock":true},{"title":"2500 FT","offer_id":55740143993201,"sku":"NNC616857","price":0.0,"currency_code":"USD","in_stock":true},{"title":"5000 FT","offer_id":55740144025969,"sku":"NNC616858","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_dde84252-932f-408b-9bc2-3fc528015d56.png?v=1754982613"},{"product_id":"12-awg-5c-copper-pe-pvc-insulation-pvc-jacket-control-cable-600v","title":"12 AWG 5C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85013_1.pdf?v=1754982162\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 5C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Polyethylene and Polyvinyl Chloride (PE\/PVC) Insulation Polyvinyl Chloride (PVC) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e12 AWG 5C Multi conductor control cable, Copper control cable, PVC insulated control wire, PE insulation control cable, PVC jacket copper cable, Multi core copper control wire, Industrial control cable PVC, 12 AWG 5C Electrical multi conductor cable, Copper PVC sheathed control cable, 12 AWG 5C Flexible control cable PVC jacket.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA CSA marking is available upon request\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 1\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation:\u003cbr\u003e\u003c\/b\u003ePolyethylene (PE) 20 Mils thick and Polyvinyl Chloride (PVC) 10 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller:\u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder:\u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eRip Chord:\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket:\u003cbr\u003e\u003c\/b\u003ePolyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 12 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 5\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.087\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 60\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e 0.537\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 102\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 188\u003cbr\u003e\u003cstrong\u003e• DC Resistance Ω \/1000ft: \u003c\/strong\u003e 1.660 \u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C Ω \/1000ft:\u003c\/strong\u003e 2.075\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 2.0\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  16\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  20\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  20\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 325.114px; height: 35.5966px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e617416\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55720057569649,"sku":"NNC617416","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_dde84252-932f-408b-9bc2-3fc528015d56.png?v=1754982613"},{"product_id":"12-awg-6c-copper-pe-pvc-insulation-pvc-jacket-control-cable-600v","title":"12 AWG 6C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85013_1.pdf?v=1754982162\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 6C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Polyethylene and Polyvinyl Chloride (PE\/PVC) Insulation Polyvinyl Chloride (PVC) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e12 AWG 6C Multi conductor control cable, Copper control cable, PVC insulated control wire, PE insulation control cable, PVC jacket copper cable, Multi core copper control wire, Industrial control cable PVC, 12 AWG 6C Electrical multi conductor cable, Copper PVC sheathed control cable, 12 AWG 6C Flexible control cable PVC jacket.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA CSA marking is available upon request\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 1\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation:\u003cbr\u003e\u003c\/b\u003ePolyethylene (PE) 20 Mils thick and Polyvinyl Chloride (PVC) 10 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller:\u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder:\u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eRip Chord:\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket:\u003cbr\u003e\u003c\/b\u003ePolyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 12 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 6\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.087\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 45\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e 0.532\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 122\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 214\u003cbr\u003e\u003cstrong\u003e• DC Resistance Ω \/1000ft: \u003c\/strong\u003e 1.660 \u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C Ω \/1000ft:\u003c\/strong\u003e 2.075\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 2.1\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  16\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  20\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  20\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"width: 325.114px; height: 35.5966px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e619173\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"2000 FT","offer_id":55740151103857,"sku":"NNC619173","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_dde84252-932f-408b-9bc2-3fc528015d56.png?v=1754982613"},{"product_id":"12-awg-7c-copper-pe-pvc-insulation-pvc-jacket-control-cable-600v","title":"12 AWG 7C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85013_1.pdf?v=1754982162\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 7C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Polyethylene and Polyvinyl Chloride (PE\/PVC) Insulation Polyvinyl Chloride (PVC) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e12 AWG 7C Multi conductor control cable, Copper control cable, PVC insulated control wire, PE insulation control cable, PVC jacket copper cable, Multi core copper control wire, Industrial control cable PVC, 12 AWG 7C Electrical multi conductor cable, Copper PVC sheathed control cable, 12 AWG 7C Flexible control cable PVC jacket.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA CSA marking is available upon request\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 1\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation:\u003cbr\u003e\u003c\/b\u003ePolyethylene (PE) 20 Mils thick and Polyvinyl Chloride (PVC) 10 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller:\u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder:\u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eRip Chord:\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket:\u003cbr\u003e\u003c\/b\u003ePolyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 12 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 7\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.087\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 60\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e 0.582\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  143\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  247\u003cbr\u003e\u003cstrong\u003e• DC Resistance Ω \/1000ft: \u003c\/strong\u003e 1.660 \u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C Ω \/1000ft:\u003c\/strong\u003e 2.075\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 2.3\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  14\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e   17\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  20\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 325.114px; height: 35.5966px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e617421\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"1000 FT","offer_id":55740154249585,"sku":"NNC617421","price":0.0,"currency_code":"USD","in_stock":true},{"title":"5000 FT","offer_id":55740154282353,"sku":"NNC617422","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_dde84252-932f-408b-9bc2-3fc528015d56.png?v=1754982613"},{"product_id":"12-awg-7c-copper-pe-pvc-insulation-pvc-jacket-control-cable-1000v","title":"12 AWG 7C Copper PE\/PVC Insulation PVC Jacket Control Cable 1000V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85013_1.pdf?v=1754982162\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 7C Copper PE\/PVC Insulation PVC Jacket Control Cable 1000V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Polyethylene and Polyvinyl Chloride (PE\/PVC) Insulation Polyvinyl Chloride (PVC) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e12 AWG 7C Multi conductor control cable, Copper control cable, PVC insulated control wire, PE insulation control cable, PVC jacket copper cable, Multi core copper control wire, Industrial control cable PVC, 12 AWG 7C Electrical multi conductor cable, Copper PVC sheathed control cable, 12 AWG 7C Flexible control cable PVC jacket.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA CSA marking is available upon request\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 1\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation:\u003cbr\u003e\u003c\/b\u003ePolyethylene (PE) 20 Mils thick and Polyvinyl Chloride (PVC) 10 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller:\u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder:\u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eRip Chord:\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket:\u003cbr\u003e\u003c\/b\u003ePolyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 12 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 7\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.087\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 45\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 60\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e 0.668\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  143\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e   272\u003cbr\u003e\u003cstrong\u003e• DC Resistance Ω \/1000ft: \u003c\/strong\u003e 1.660 \u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C Ω \/1000ft:\u003c\/strong\u003e 2.075\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 2.7\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  14\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e   17\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  20\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 325.114px; height: 35.5966px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e577810\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55720059568497,"sku":"NNC577810","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_dde84252-932f-408b-9bc2-3fc528015d56.png?v=1754982613"},{"product_id":"12-awg-8c-copper-pe-pvc-insulation-pvc-jacket-control-cable-600v","title":"12 AWG 8C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85013_1.pdf?v=1754982162\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 8C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Polyethylene and Polyvinyl Chloride (PE\/PVC) Insulation Polyvinyl Chloride (PVC) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e12 AWG 8C Multi conductor control cable, Copper control cable, PVC insulated control wire, PE insulation control cable, PVC jacket copper cable, Multi core copper control wire, Industrial control cable PVC, 12 AWG 8C Electrical multi conductor cable, Copper PVC sheathed control cable, 12 AWG 8C Flexible control cable PVC jacket.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA CSA marking is available upon request\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 1\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation:\u003cbr\u003e\u003c\/b\u003ePolyethylene (PE) 20 Mils thick and Polyvinyl Chloride (PVC) 10 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller:\u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder:\u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eRip Chord:\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket:\u003cbr\u003e\u003c\/b\u003ePolyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 12 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 8\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.087\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 60\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e 0.607\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  163\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  288\u003cbr\u003e\u003cstrong\u003e• DC Resistance Ω \/1000ft: \u003c\/strong\u003e 1.660 \u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C Ω \/1000ft:\u003c\/strong\u003e 2.075\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 2.4\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  14\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e   17\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  20\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55720061403505,"sku":"NNC1137","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_dde84252-932f-408b-9bc2-3fc528015d56.png?v=1754982613"},{"product_id":"12-awg-9c-copper-pe-pvc-insulation-pvc-jacket-control-cable-600v","title":"12 AWG 9C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85013_1.pdf?v=1754982162\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 9C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Polyethylene and Polyvinyl Chloride (PE\/PVC) Insulation Polyvinyl Chloride (PVC) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e12 AWG 9C Multi conductor control cable, Copper control cable, PVC insulated control wire, PE insulation control cable, PVC jacket copper cable, Multi core copper control wire, Industrial control cable PVC, 12 AWG 9C Electrical multi conductor cable, Copper PVC sheathed control cable, 12 AWG 9C Flexible control cable PVC jacket.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA CSA marking is available upon request\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 1\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation:\u003cbr\u003e\u003c\/b\u003ePolyethylene (PE) 20 Mils thick and Polyvinyl Chloride (PVC) 10 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller:\u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder:\u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eRip Chord:\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket:\u003cbr\u003e\u003c\/b\u003ePolyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 12 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 9\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.087\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 60\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e  0.651\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e   183\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  324\u003cbr\u003e\u003cstrong\u003e• DC Resistance Ω \/1000ft: \u003c\/strong\u003e 1.660 \u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C Ω \/1000ft:\u003c\/strong\u003e 2.075\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 2.6\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  14\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e   17\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  20\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 325.114px; height: 35.5966px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e619382\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55720061665649,"sku":"NNC619382","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_dde84252-932f-408b-9bc2-3fc528015d56.png?v=1754982613"},{"product_id":"12-awg-10c-copper-pe-pvc-insulation-pvc-jacket-control-cable-600v","title":"12 AWG 10C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85013_1.pdf?v=1754982162\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 10C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Polyethylene and Polyvinyl Chloride (PE\/PVC) Insulation Polyvinyl Chloride (PVC) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e12 AWG 10C Multi conductor control cable, Copper control cable, PVC insulated control wire, PE insulation control cable, PVC jacket copper cable, Multi core copper control wire, Industrial control cable PVC, 12 AWG 10C Electrical multi conductor cable, Copper PVC sheathed control cable, 12 AWG 10C Flexible control cable PVC jacket.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA CSA marking is available upon request\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 1\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation:\u003cbr\u003e\u003c\/b\u003ePolyethylene (PE) 20 Mils thick and Polyvinyl Chloride (PVC) 10 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller:\u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder:\u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eRip Chord:\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket:\u003cbr\u003e\u003c\/b\u003ePolyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 12 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 10\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.087\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 60\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e  0.709\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  204\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 365\u003cbr\u003e\u003cstrong\u003e• DC Resistance Ω \/1000ft: \u003c\/strong\u003e 1.660 \u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C Ω \/1000ft:\u003c\/strong\u003e 2.075\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 2.8\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  10\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  12\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 15\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55720061895025,"sku":"NNC1138","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_dde84252-932f-408b-9bc2-3fc528015d56.png?v=1754982613"},{"product_id":"12-awg-12c-19-strand-copper-pe-pvc-insulation-pvc-jacket-control-cable-600v","title":"12 AWG 12C 19 Strand Copper PE\/PVC Insulation PVC Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85013_1.pdf?v=1754982162\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 12C 19 Strand Copper PE\/PVC Insulation PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Polyethylene and Polyvinyl Chloride (PE\/PVC) Insulation Polyvinyl Chloride (PVC) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e12 AWG 12C Multi conductor control cable, Copper control cable, PVC insulated control wire, PE insulation control cable, PVC jacket copper cable, Multi core copper control wire, Industrial control cable PVC, 12 AWG 12C Electrical multi conductor cable, Copper PVC sheathed control cable, 12 AWG 12C Flexible control cable PVC jacket.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA CSA marking is available upon request\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 1\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e19 strands class C compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation:\u003cbr\u003e\u003c\/b\u003ePolyethylene (PE) 20 Mils thick and Polyvinyl Chloride (PVC) 10 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller:\u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder:\u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eRip Chord:\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket:\u003cbr\u003e\u003c\/b\u003ePolyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 12 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 12\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.087\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 60\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e  0.752\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  244\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  396\u003cbr\u003e\u003cstrong\u003e• DC Resistance Ω \/1000ft: \u003c\/strong\u003e 1.660 \u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C Ω \/1000ft:\u003c\/strong\u003e 2.075\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 2.9\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  10\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  12\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 15\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 64.2898px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 41.2926px;\"\u003e\n\u003ctd style=\"width: 325.114px; height: 41.2926px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.9972px;\"\u003e\n\u003ctd style=\"width: 160.597px; height: 22.9972px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px; height: 22.9972px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e619993\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55720062419313,"sku":"NNC619993","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_dde84252-932f-408b-9bc2-3fc528015d56.png?v=1754982613"},{"product_id":"12-awg-12c-copper-pe-pvc-insulation-pvc-jacket-control-cable-600v","title":"12 AWG 12C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85013_1.pdf?v=1754982162\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 12C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Polyethylene and Polyvinyl Chloride (PE\/PVC) Insulation Polyvinyl Chloride (PVC) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e12 AWG 12C Multi conductor control cable, Copper control cable, PVC insulated control wire, PE insulation control cable, PVC jacket copper cable, Multi core copper control wire, Industrial control cable PVC, 12 AWG 12C Electrical multi conductor cable, Copper PVC sheathed control cable, 12 AWG 12C Flexible control cable PVC jacket.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA CSA marking is available upon request\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 1\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation:\u003cbr\u003e\u003c\/b\u003ePolyethylene (PE) 20 Mils thick and Polyvinyl Chloride (PVC) 10 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller:\u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder:\u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eRip Chord:\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket:\u003cbr\u003e\u003c\/b\u003ePolyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 12 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 12\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.087\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 60\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e  0.759\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  244\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  396\u003cbr\u003e\u003cstrong\u003e• DC Resistance Ω \/1000ft: \u003c\/strong\u003e 1.660 \u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C Ω \/1000ft:\u003c\/strong\u003e 2.075\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 2.9\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  10\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  12\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 15\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 64.2898px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 41.2926px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 325.114px; height: 41.2926px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.9972px;\"\u003e\n\u003ctd style=\"width: 160.597px; height: 22.9972px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px; height: 22.9972px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e617420\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"2500 FT","offer_id":55740155199857,"sku":"NNC617420","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_dde84252-932f-408b-9bc2-3fc528015d56.png?v=1754982613"},{"product_id":"12-awg-15c-copper-pe-pvc-insulation-pvc-jacket-control-cable-600v","title":"12 AWG 15C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85013_1.pdf?v=1754982162\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 15C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Polyethylene and Polyvinyl Chloride (PE\/PVC) Insulation Polyvinyl Chloride (PVC) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e12 AWG 15C Multi conductor control cable, Copper control cable, PVC insulated control wire, PE insulation control cable, PVC jacket copper cable, Multi core copper control wire, Industrial control cable PVC, 12 AWG 15C Electrical multi conductor cable, Copper PVC sheathed control cable, 12 AWG 15C Flexible control cable PVC jacket.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA CSA marking is available upon request\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 1\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation:\u003cbr\u003e\u003c\/b\u003ePolyethylene (PE) 20 Mils thick and Polyvinyl Chloride (PVC) 10 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller:\u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder:\u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eRip Chord:\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket:\u003cbr\u003e\u003c\/b\u003ePolyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 12 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 15\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.087\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 60\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e  0.813\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e   305\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e   516\u003cbr\u003e\u003cstrong\u003e• DC Resistance Ω \/1000ft: \u003c\/strong\u003e 1.660 \u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C Ω \/1000ft:\u003c\/strong\u003e 2.075\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 3.3\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  10\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  12\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 15\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55720174584177,"sku":"NNC1139","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_dde84252-932f-408b-9bc2-3fc528015d56.png?v=1754982613"},{"product_id":"12-awg-19c-copper-pe-pvc-insulation-pvc-jacket-control-cable-600v","title":"12 AWG 19C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85013_1.pdf?v=1754982162\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 19C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Polyethylene and Polyvinyl Chloride (PE\/PVC) Insulation Polyvinyl Chloride (PVC) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e12 AWG 19C Multi conductor control cable, Copper control cable, PVC insulated control wire, PE insulation control cable, PVC jacket copper cable, Multi core copper control wire, Industrial control cable PVC, 12 AWG 19C Electrical multi conductor cable, Copper PVC sheathed control cable, 12 AWG 19C Flexible control cable PVC jacket.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA CSA marking is available upon request\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 1\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation:\u003cbr\u003e\u003c\/b\u003ePolyethylene (PE) 20 Mils thick and Polyvinyl Chloride (PVC) 10 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller:\u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder:\u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eRip Chord:\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket:\u003cbr\u003e\u003c\/b\u003ePolyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 12 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.087\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e  0.896\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  387\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 657\u003cbr\u003e\u003cstrong\u003e• DC Resistance Ω \/1000ft: \u003c\/strong\u003e 1.660 \u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C Ω \/1000ft:\u003c\/strong\u003e 2.075\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 3.6\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  10\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  12\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 15\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55720175567217,"sku":"NNC1140","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_dde84252-932f-408b-9bc2-3fc528015d56.png?v=1754982613"},{"product_id":"12-awg-20c-copper-pe-pvc-insulation-pvc-jacket-control-cable-600v","title":"12 AWG 20C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85013_1.pdf?v=1754982162\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 20C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Polyethylene and Polyvinyl Chloride (PE\/PVC) Insulation Polyvinyl Chloride (PVC) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e12 AWG 20C Multi conductor control cable, Copper control cable, PVC insulated control wire, PE insulation control cable, PVC jacket copper cable, Multi core copper control wire, Industrial control cable PVC, 12 AWG 20C Electrical multi conductor cable, Copper PVC sheathed control cable, 12 AWG 20C Flexible control cable PVC jacket.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA CSA marking is available upon request\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 1\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation:\u003cbr\u003e\u003c\/b\u003ePolyethylene (PE) 20 Mils thick and Polyvinyl Chloride (PVC) 10 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller:\u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder:\u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eRip Chord:\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket:\u003cbr\u003e\u003c\/b\u003ePolyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 12 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 20\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.087\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e   0.942\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  407\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 699\u003cbr\u003e\u003cstrong\u003e• DC Resistance Ω \/1000ft: \u003c\/strong\u003e 1.660 \u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C Ω \/1000ft:\u003c\/strong\u003e 2.075\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 3.8\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  10\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  12\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 15\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55720176091505,"sku":"NNC1141","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_dde84252-932f-408b-9bc2-3fc528015d56.png?v=1754982613"},{"product_id":"12-awg-25c-copper-pe-pvc-insulation-pvc-jacket-control-cable-600v","title":"12 AWG 25C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85013_1.pdf?v=1754982162\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 25C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Polyethylene and Polyvinyl Chloride (PE\/PVC) Insulation Polyvinyl Chloride (PVC) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e12 AWG 25C Multi conductor control cable, Copper control cable, PVC insulated control wire, PE insulation control cable, PVC jacket copper cable, Multi core copper control wire, Industrial control cable PVC, 12 AWG 25C Electrical multi conductor cable, Copper PVC sheathed control cable, 12 AWG 25C Flexible control cable PVC jacket.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA CSA marking is available upon request\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 1\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation:\u003cbr\u003e\u003c\/b\u003ePolyethylene (PE) 20 Mils thick and Polyvinyl Chloride (PVC) 10 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller:\u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder:\u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eRip Chord:\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket:\u003cbr\u003e\u003c\/b\u003ePolyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 12 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 25\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.087\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e 1.043\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  509\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 860\u003cbr\u003e\u003cstrong\u003e• DC Resistance Ω \/1000ft: \u003c\/strong\u003e 1.660 \u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C Ω \/1000ft:\u003c\/strong\u003e 2.075\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 5.2\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e\u003cspan\u003e   9\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e   11\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  13\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55720177009009,"sku":"NNC1142","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_dde84252-932f-408b-9bc2-3fc528015d56.png?v=1754982613"},{"product_id":"12-awg-30c-copper-pe-pvc-insulation-pvc-jacket-control-cable-600v","title":"12 AWG 30C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85013_1.pdf?v=1754982162\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 30C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Polyethylene and Polyvinyl Chloride (PE\/PVC) Insulation Polyvinyl Chloride (PVC) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e12 AWG 30C Multi conductor control cable, Copper control cable, PVC insulated control wire, PE insulation control cable, PVC jacket copper cable, Multi core copper control wire, Industrial control cable PVC, 12 AWG 30C Electrical multi conductor cable, Copper PVC sheathed control cable, 12 AWG 30C Flexible control cable PVC jacket.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA CSA marking is available upon request\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 1\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation:\u003cbr\u003e\u003c\/b\u003ePolyethylene (PE) 20 Mils thick and Polyvinyl Chloride (PVC) 10 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller:\u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder:\u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eRip Chord:\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket:\u003cbr\u003e\u003c\/b\u003ePolyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 12 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.087\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e 1.104\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e   611\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  1005\u003cbr\u003e\u003cstrong\u003e• DC Resistance Ω \/1000ft: \u003c\/strong\u003e 1.660 \u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C Ω \/1000ft:\u003c\/strong\u003e 2.075\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 5.5\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 9\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 11\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  13\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55720180580721,"sku":"NNC1143","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_dde84252-932f-408b-9bc2-3fc528015d56.png?v=1754982613"},{"product_id":"12-awg-37c-copper-pe-pvc-insulation-pvc-jacket-control-cable-600v","title":"12 AWG 37C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85013_1.pdf?v=1754982162\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 37C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Polyethylene and Polyvinyl Chloride (PE\/PVC) Insulation Polyvinyl Chloride (PVC) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e12 AWG 37C Multi conductor control cable, Copper control cable, PVC insulated control wire, PE insulation control cable, PVC jacket copper cable, Multi core copper control wire, Industrial control cable PVC, 12 AWG 37C Electrical multi conductor cable, Copper PVC sheathed control cable, 12 AWG 37C Flexible control cable PVC jacket.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA CSA marking is available upon request\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 1\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation:\u003cbr\u003e\u003c\/b\u003ePolyethylene (PE) 20 Mils thick and Polyvinyl Chloride (PVC) 10 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller:\u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder:\u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eRip Chord:\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket:\u003cbr\u003e\u003c\/b\u003ePolyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 12 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 37\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.087\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e 1.191\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  753\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  1211\u003cbr\u003e\u003cstrong\u003e• DC Resistance Ω \/1000ft: \u003c\/strong\u003e 1.660 \u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C Ω \/1000ft:\u003c\/strong\u003e 2.075\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 6.0\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 8\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 10\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  12\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55720186642801,"sku":"NNC1144","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_dde84252-932f-408b-9bc2-3fc528015d56.png?v=1754982613"},{"product_id":"10-awg-2c-copper-pe-pvc-insulation-pvc-jacket-control-cable-600v","title":"10 AWG 2C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85013_1.pdf?v=1754982162\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e10 AWG 2C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Polyethylene and Polyvinyl Chloride (PE\/PVC) Insulation Polyvinyl Chloride (PVC) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e10 AWG 2C Multi conductor control cable, Copper control cable, PVC insulated control wire, PE insulation control cable, PVC jacket copper cable, Multi core copper control wire, Industrial control cable PVC, 10 AWG 2C Electrical multi conductor cable, Copper PVC sheathed control cable, 10 AWG 2C Flexible control cable PVC jacket.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA CSA marking is available upon request\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 1\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation:\u003cbr\u003e\u003c\/b\u003ePolyethylene (PE) 20 Mils thick and Polyvinyl Chloride (PVC) 10 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller:\u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder:\u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eRip Chord:\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket:\u003cbr\u003e\u003c\/b\u003ePolyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 10 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 2\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.111\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 45\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e 0.431\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e   65\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  124\u003cbr\u003e\u003cstrong\u003e• DC Resistance Ω \/1000ft: \u003c\/strong\u003e 1.040\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C Ω \/1000ft:\u003c\/strong\u003e  1.300\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 1.7\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 325.114px; height: 35.5966px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e618719\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"500 FT","offer_id":55740158509425,"sku":"NNC618719","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 FT","offer_id":55740158542193,"sku":"NNC618720","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1500 FT","offer_id":55740158574961,"sku":"NNC618721","price":0.0,"currency_code":"USD","in_stock":true},{"title":"2500 FT","offer_id":55740158607729,"sku":"NNC618722","price":0.0,"currency_code":"USD","in_stock":true},{"title":"3000 FT","offer_id":55740158640497,"sku":"NNC618723","price":0.0,"currency_code":"USD","in_stock":true},{"title":"5000 FT","offer_id":55740158673265,"sku":"NNC618724","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_dde84252-932f-408b-9bc2-3fc528015d56.png?v=1754982613"},{"product_id":"10-awg-3c-copper-pe-pvc-insulation-pvc-jacket-control-cable-600v","title":"10 AWG 3C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85013_1.pdf?v=1754982162\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e10 AWG 3C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Polyethylene and Polyvinyl Chloride (PE\/PVC) Insulation Polyvinyl Chloride (PVC) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e10 AWG 3C Multi conductor control cable, Copper control cable, PVC insulated control wire, PE insulation control cable, PVC jacket copper cable, Multi core copper control wire, Industrial control cable PVC, 10 AWG 3C Electrical multi conductor cable, Copper PVC sheathed control cable, 10 AWG 3C Flexible control cable PVC jacket.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA CSA marking is available upon request\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 1\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation:\u003cbr\u003e\u003c\/b\u003ePolyethylene (PE) 20 Mils thick and Polyvinyl Chloride (PVC) 10 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller:\u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder:\u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eRip Chord:\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket:\u003cbr\u003e\u003c\/b\u003ePolyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 10 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 3\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.111\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 45\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e 0.459\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  97\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  165\u003cbr\u003e\u003cstrong\u003e• DC Resistance Ω \/1000ft: \u003c\/strong\u003e 1.040\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C Ω \/1000ft:\u003c\/strong\u003e  1.300\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 1.8\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"width: 325.114px; height: 35.5966px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e619117\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"500 FT","offer_id":55740163588465,"sku":"NNC619117","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 FT","offer_id":55740163621233,"sku":"NNC619118","price":0.0,"currency_code":"USD","in_stock":true},{"title":"5000 FT","offer_id":55740163654001,"sku":"NNC619119","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_dde84252-932f-408b-9bc2-3fc528015d56.png?v=1754982613"},{"product_id":"10-awg-4c-copper-pe-pvc-insulation-pvc-jacket-control-cable-600v","title":"10 AWG 4C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85013_1.pdf?v=1754982162\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e10 AWG 4C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Polyethylene and Polyvinyl Chloride (PE\/PVC) Insulation Polyvinyl Chloride (PVC) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e10 AWG 4C Multi conductor control cable, Copper control cable, PVC insulated control wire, PE insulation control cable, PVC jacket copper cable, Multi core copper control wire, Industrial control cable PVC, 10 AWG 4C Electrical multi conductor cable, Copper PVC sheathed control cable, 10 AWG 4C Flexible control cable PVC jacket.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA CSA marking is available upon request\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 1\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation:\u003cbr\u003e\u003c\/b\u003ePolyethylene (PE) 20 Mils thick and Polyvinyl Chloride (PVC) 10 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller:\u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder:\u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eRip Chord:\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket:\u003cbr\u003e\u003c\/b\u003ePolyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 10 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 4\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.111\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 60\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e  0.540\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 130\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  223\u003cbr\u003e\u003cstrong\u003e• DC Resistance Ω \/1000ft: \u003c\/strong\u003e 1.040\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C Ω \/1000ft:\u003c\/strong\u003e  1.300\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 2.2\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  24\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  28\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 325.114px; height: 35.5966px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e618720\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55720192999793,"sku":"NNC618720","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_dde84252-932f-408b-9bc2-3fc528015d56.png?v=1754982613"},{"product_id":"10-awg-5c-copper-pe-pvc-insulation-pvc-jacket-control-cable-600v","title":"10 AWG 5C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85013_1.pdf?v=1754982162\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e10 AWG 5C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Polyethylene and Polyvinyl Chloride (PE\/PVC) Insulation Polyvinyl Chloride (PVC) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e10 AWG 5C Multi conductor control cable, Copper control cable, PVC insulated control wire, PE insulation control cable, PVC jacket copper cable, Multi core copper control wire, Industrial control cable PVC, 10 AWG 5C Electrical multi conductor cable, Copper PVC sheathed control cable, 10 AWG 5C Flexible control cable PVC jacket.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA CSA marking is available upon request\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 1\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation:\u003cbr\u003e\u003c\/b\u003ePolyethylene (PE) 20 Mils thick and Polyvinyl Chloride (PVC) 10 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller:\u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder:\u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eRip Chord:\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket:\u003cbr\u003e\u003c\/b\u003ePolyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 10 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 5\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.111\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 60\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e   0.581\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 162\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  273\u003cbr\u003e\u003cstrong\u003e• DC Resistance Ω \/1000ft: \u003c\/strong\u003e 1.040\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C Ω \/1000ft:\u003c\/strong\u003e  1.300\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 2.3\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  24\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  28\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55720196211057,"sku":"NNC1145","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_dde84252-932f-408b-9bc2-3fc528015d56.png?v=1754982613"},{"product_id":"10-awg-6c-copper-pe-pvc-insulation-pvc-jacket-control-cable-600v","title":"10 AWG 6C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85013_1.pdf?v=1754982162\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e10 AWG 6C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Polyethylene and Polyvinyl Chloride (PE\/PVC) Insulation Polyvinyl Chloride (PVC) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e10 AWG 6C Multi conductor control cable, Copper control cable, PVC insulated control wire, PE insulation control cable, PVC jacket copper cable, Multi core copper control wire, Industrial control cable PVC, 10 AWG 6C Electrical multi conductor cable, Copper PVC sheathed control cable, 10 AWG 6C Flexible control cable PVC jacket.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA CSA marking is available upon request\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 1\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation:\u003cbr\u003e\u003c\/b\u003ePolyethylene (PE) 20 Mils thick and Polyvinyl Chloride (PVC) 10 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller:\u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder:\u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eRip Chord:\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket:\u003cbr\u003e\u003c\/b\u003ePolyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 10 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 6\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.111\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 60\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e 0.632\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 194\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 323\u003cbr\u003e\u003cstrong\u003e• DC Resistance Ω \/1000ft: \u003c\/strong\u003e 1.040\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C Ω \/1000ft:\u003c\/strong\u003e  1.300\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 2.5\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  24\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  28\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55720197128561,"sku":"NNC1146","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_dde84252-932f-408b-9bc2-3fc528015d56.png?v=1754982613"},{"product_id":"10-awg-7c-copper-pe-pvc-insulation-pvc-jacket-control-cable-600v","title":"10 AWG 7C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85013_1.pdf?v=1754982162\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e10 AWG 7C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Polyethylene and Polyvinyl Chloride (PE\/PVC) Insulation Polyvinyl Chloride (PVC) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e10 AWG 7C Multi conductor control cable, Copper control cable, PVC insulated control wire, PE insulation control cable, PVC jacket copper cable, Multi core copper control wire, Industrial control cable PVC, 10 AWG 7C Electrical multi conductor cable, Copper PVC sheathed control cable, 10 AWG 7C Flexible control cable PVC jacket.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA CSA marking is available upon request\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 1\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation:\u003cbr\u003e\u003c\/b\u003ePolyethylene (PE) 20 Mils thick and Polyvinyl Chloride (PVC) 10 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller:\u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder:\u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eRip Chord:\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket:\u003cbr\u003e\u003c\/b\u003ePolyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 10 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 7\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.111\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 60\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e  0.632\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 227\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 358\u003cbr\u003e\u003cstrong\u003e• DC Resistance Ω \/1000ft: \u003c\/strong\u003e 1.040\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C Ω \/1000ft:\u003c\/strong\u003e  1.300\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 2.5\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  21\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  24\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 28\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 325.114px; height: 35.5966px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e618968\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55720203452785,"sku":"NNC618968","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_dde84252-932f-408b-9bc2-3fc528015d56.png?v=1754982613"},{"product_id":"10-awg-8c-copper-pe-pvc-insulation-pvc-jacket-control-cable-600v","title":"10 AWG 8C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85013_1.pdf?v=1754982162\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e10 AWG 8C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Polyethylene and Polyvinyl Chloride (PE\/PVC) Insulation Polyvinyl Chloride (PVC) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e10 AWG 8C Multi conductor control cable, Copper control cable, PVC insulated control wire, PE insulation control cable, PVC jacket copper cable, Multi core copper control wire, Industrial control cable PVC, 10 AWG 8C Electrical multi conductor cable, Copper PVC sheathed control cable, 10 AWG 8C Flexible control cable PVC jacket.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA CSA marking is available upon request\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 1\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation:\u003cbr\u003e\u003c\/b\u003ePolyethylene (PE) 20 Mils thick and Polyvinyl Chloride (PVC) 10 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller:\u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder:\u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eRip Chord:\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket:\u003cbr\u003e\u003c\/b\u003ePolyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 10 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 8\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.111\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 60\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e 0.685\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 259\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 410\u003cbr\u003e\u003cstrong\u003e• DC Resistance Ω \/1000ft: \u003c\/strong\u003e 1.040\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C Ω \/1000ft:\u003c\/strong\u003e  1.300\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 2.7\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  21\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  24\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 28\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"width: 325.114px; height: 35.5966px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e619179\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"2500 FT","offer_id":55740172796273,"sku":"NNC619179","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_dde84252-932f-408b-9bc2-3fc528015d56.png?v=1754982613"},{"product_id":"10-awg-9c-copper-pe-pvc-insulation-pvc-jacket-control-cable-600v","title":"10 AWG 9C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85013_1.pdf?v=1754982162\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e10 AWG 9C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Polyethylene and Polyvinyl Chloride (PE\/PVC) Insulation Polyvinyl Chloride (PVC) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e10 AWG 9C Multi conductor control cable, Copper control cable, PVC insulated control wire, PE insulation control cable, PVC jacket copper cable, Multi core copper control wire, Industrial control cable PVC, 10 AWG 9C Electrical multi conductor cable, Copper PVC sheathed control cable, 10 AWG 9C Flexible control cable PVC jacket.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA CSA marking is available upon request\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 1\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation:\u003cbr\u003e\u003c\/b\u003ePolyethylene (PE) 20 Mils thick and Polyvinyl Chloride (PVC) 10 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller:\u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder:\u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eRip Chord:\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket:\u003cbr\u003e\u003c\/b\u003ePolyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 10 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 9\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.111\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 60\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e 0.736\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 291\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 461\u003cbr\u003e\u003cstrong\u003e• DC Resistance Ω \/1000ft: \u003c\/strong\u003e 1.040\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C Ω \/1000ft:\u003c\/strong\u003e  1.300\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 2.9\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  21\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  24\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 28\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 325.114px; height: 35.5966px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e606782\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"1000 FT","offer_id":55740186231153,"sku":"NNC606782","price":0.0,"currency_code":"USD","in_stock":true},{"title":"2500 FT","offer_id":55740186263921,"sku":"NNC606783","price":0.0,"currency_code":"USD","in_stock":true},{"title":"5000 FT","offer_id":55740186296689,"sku":"NNC606784","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_dde84252-932f-408b-9bc2-3fc528015d56.png?v=1754982613"},{"product_id":"10-awg-10c-copper-pe-pvc-insulation-pvc-jacket-control-cable-600v","title":"10 AWG 10C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85013_1.pdf?v=1754982162\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e10 AWG 10C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Polyethylene and Polyvinyl Chloride (PE\/PVC) Insulation Polyvinyl Chloride (PVC) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e10 AWG 10C Multi conductor control cable, Copper control cable, PVC insulated control wire, PE insulation control cable, PVC jacket copper cable, Multi core copper control wire, Industrial control cable PVC, 10 AWG 10C Electrical multi conductor cable, Copper PVC sheathed control cable, 10 AWG 10C Flexible control cable PVC jacket.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA CSA marking is available upon request\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 1\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation:\u003cbr\u003e\u003c\/b\u003ePolyethylene (PE) 20 Mils thick and Polyvinyl Chloride (PVC) 10 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller:\u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder:\u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eRip Chord:\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket:\u003cbr\u003e\u003c\/b\u003ePolyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 10 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 10\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.111\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 60\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e 0.803\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  324\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  519\u003cbr\u003e\u003cstrong\u003e• DC Resistance Ω \/1000ft: \u003c\/strong\u003e 1.040\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C Ω \/1000ft:\u003c\/strong\u003e  1.300\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 3.2\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  15\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  17\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  20\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"width: 325.114px; height: 35.5966px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e619181\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55720325742961,"sku":"NNC619181","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_dde84252-932f-408b-9bc2-3fc528015d56.png?v=1754982613"},{"product_id":"10-awg-12c-copper-pe-pvc-insulation-pvc-jacket-control-cable-600v","title":"10 AWG 12C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85013_1.pdf?v=1754982162\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e10 AWG 12C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Polyethylene and Polyvinyl Chloride (PE\/PVC) Insulation Polyvinyl Chloride (PVC) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e10 AWG 12C Multi conductor control cable, Copper control cable, PVC insulated control wire, PE insulation control cable, PVC jacket copper cable, Multi core copper control wire, Industrial control cable PVC, 10 AWG 12C Electrical multi conductor cable, Copper PVC sheathed control cable, 10 AWG 12C Flexible control cable PVC jacket.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA CSA marking is available upon request\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 1\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation:\u003cbr\u003e\u003c\/b\u003ePolyethylene (PE) 20 Mils thick and Polyvinyl Chloride (PVC) 10 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller:\u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder:\u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eRip Chord:\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket:\u003cbr\u003e\u003c\/b\u003ePolyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 10 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 12\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.111\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 60\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e 0.830\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e   389\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  600\u003cbr\u003e\u003cstrong\u003e• DC Resistance Ω \/1000ft: \u003c\/strong\u003e 1.040\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C Ω \/1000ft:\u003c\/strong\u003e  1.300\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 3.3\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  15\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  17\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  20\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 325.114px; height: 35.5966px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e618911\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55720326726001,"sku":"NNC618911","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_dde84252-932f-408b-9bc2-3fc528015d56.png?v=1754982613"},{"product_id":"10-awg-15c-copper-pe-pvc-insulation-pvc-jacket-control-cable-600v","title":"10 AWG 15C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85013_1.pdf?v=1754982162\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e10 AWG 15C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Polyethylene and Polyvinyl Chloride (PE\/PVC) Insulation Polyvinyl Chloride (PVC) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e10 AWG 15C Multi conductor control cable, Copper control cable, PVC insulated control wire, PE insulation control cable, PVC jacket copper cable, Multi core copper control wire, Industrial control cable PVC, 10 AWG 15C Electrical multi conductor cable, Copper PVC sheathed control cable, 10 AWG 15C Flexible control cable PVC jacket.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA CSA marking is available upon request\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 1\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation:\u003cbr\u003e\u003c\/b\u003ePolyethylene (PE) 20 Mils thick and Polyvinyl Chloride (PVC) 10 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller:\u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder:\u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eRip Chord:\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket:\u003cbr\u003e\u003c\/b\u003ePolyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 10 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 15\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.111\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e  0.964\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 486\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft): \u003c\/strong\u003e\u003cspan\u003e777\u003cbr\u003e\u003cstrong\u003e• DC Resistance Ω \/1000ft: \u003c\/strong\u003e 1.040\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C Ω \/1000ft:\u003c\/strong\u003e  1.300\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 3.9\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  15\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  17\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  20\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55720328659313,"sku":"NNC1147","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_dde84252-932f-408b-9bc2-3fc528015d56.png?v=1754982613"},{"product_id":"10-awg-19c-copper-pe-pvc-insulation-pvc-jacket-control-cable-600v","title":"10 AWG 19C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85013_1.pdf?v=1754982162\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e10 AWG 19C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Polyethylene and Polyvinyl Chloride (PE\/PVC) Insulation Polyvinyl Chloride (PVC) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e10 AWG 19C Multi conductor control cable, Copper control cable, PVC insulated control wire, PE insulation control cable, PVC jacket copper cable, Multi core copper control wire, Industrial control cable PVC, 10 AWG 19C Electrical multi conductor cable, Copper PVC sheathed control cable, 10 AWG 19C Flexible control cable PVC jacket.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA CSA marking is available upon request\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 1\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation:\u003cbr\u003e\u003c\/b\u003ePolyethylene (PE) 20 Mils thick and Polyvinyl Chloride (PVC) 10 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller:\u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder:\u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eRip Chord:\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket:\u003cbr\u003e\u003c\/b\u003ePolyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 10 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.111\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e   1.014\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  615\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft): \u003c\/strong\u003e941\u003cspan\u003e\u003cbr\u003e\u003cstrong\u003e• DC Resistance Ω \/1000ft: \u003c\/strong\u003e 1.040\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C Ω \/1000ft:\u003c\/strong\u003e  1.300\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 5.1\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  15\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  17\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  20\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55720344224113,"sku":"NNC1148","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_dde84252-932f-408b-9bc2-3fc528015d56.png?v=1754982613"},{"product_id":"10-awg-20c-copper-pe-pvc-insulation-pvc-jacket-control-cable-600v","title":"10 AWG 20C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85013_1.pdf?v=1754982162\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e10 AWG 20C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Polyethylene and Polyvinyl Chloride (PE\/PVC) Insulation Polyvinyl Chloride (PVC) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e10 AWG 20C Multi conductor control cable, Copper control cable, PVC insulated control wire, PE insulation control cable, PVC jacket copper cable, Multi core copper control wire, Industrial control cable PVC, 10 AWG 20C Electrical multi conductor cable, Copper PVC sheathed control cable, 10 AWG 20C Flexible control cable PVC jacket.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA CSA marking is available upon request\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 1\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation:\u003cbr\u003e\u003c\/b\u003ePolyethylene (PE) 20 Mils thick and Polyvinyl Chloride (PVC) 10 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller:\u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder:\u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eRip Chord:\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket:\u003cbr\u003e\u003c\/b\u003ePolyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 10 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 20\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.111\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e  1.067\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  648\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft): \u003c\/strong\u003e1001\u003cspan\u003e\u003cbr\u003e\u003cstrong\u003e• DC Resistance Ω \/1000ft: \u003c\/strong\u003e 1.040\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C Ω \/1000ft:\u003c\/strong\u003e  1.300\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 5.3\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  15\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  17\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  20\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55720357069169,"sku":"NNC1149","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_dde84252-932f-408b-9bc2-3fc528015d56.png?v=1754982613"},{"product_id":"10-awg-25c-copper-pe-pvc-insulation-pvc-jacket-control-cable-600v","title":"10 AWG 25C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85013_1.pdf?v=1754982162\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e10 AWG 25C Copper PE\/PVC Insulation PVC Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Polyethylene and Polyvinyl Chloride (PE\/PVC) Insulation Polyvinyl Chloride (PVC) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e10 AWG 25C Multi conductor control cable, Copper control cable, PVC insulated control wire, PE insulation control cable, PVC jacket copper cable, Multi core copper control wire, Industrial control cable PVC, 10 AWG 25C Electrical multi conductor cable, Copper PVC sheathed control cable, 10 AWG 25C Flexible control cable PVC jacket.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA CSA marking is available upon request\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 1\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cb\u003e\u003cbr\u003eInsulation:\u003cbr\u003e\u003c\/b\u003ePolyethylene (PE) 20 Mils thick and Polyvinyl Chloride (PVC) 10 Mils thick for all cable sizes\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFiller:\u003cbr\u003e\u003c\/b\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eBinder:\u003cbr\u003e\u003c\/b\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cb\u003e\u003cbr\u003eRip Chord:\u003cbr\u003e\u003c\/b\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cb\u003e\u003cbr\u003eOverall Jacket:\u003cbr\u003e\u003c\/b\u003ePolyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 10 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 25\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.111\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e  1.184\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e   810\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):  \u003c\/strong\u003e1236\u003cspan\u003e\u003cbr\u003e\u003cstrong\u003e• DC Resistance Ω \/1000ft: \u003c\/strong\u003e 1.040\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°C Ω \/1000ft:\u003c\/strong\u003e  1.300\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 5.9\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 13\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 15\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 18\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55720365326705,"sku":"NNC1150","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/13_dde84252-932f-408b-9bc2-3fc528015d56.png?v=1754982613"}],"url":"https:\/\/nassaunationalcable.com\/collections\/multi-conductor-copper-pe-pvc-insulation-pvc-jacket-control-cable.oembed?page=4","provider":"NassauNationalCable","version":"1.0","type":"link"}