{"title":"Multi Conductor Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V","description":"","products":[{"product_id":"14-awg-2c-copper-fr-xlpe-lct-shielded-lszh-jacket-control-cable-600v","title":"14 AWG 2C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85045_1_1.pdf?v=1754555155\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 2C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Flame Retardant Cross Linked Polyethylene (FR-XLPE) Insulation Shielded SOLONON Low Smoke Zero Halogen (LSZH) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e14 AWG 2C Multi-Conductor CU Control Cable, 600V FR-XLPE LSZH Cable, Fire-Resistant Control Cable, XLPE Jacket Control Cable, 14 AWG 2C LSZH Control Cable, CU 600V Control Cable, Fire Retardant XLPE Cable, 14 AWG 2C Low Smoke Zero Halogen Cable, Multi-Conductor Control Wire, 14 AWG 2C 600V LSZH Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFiller:\u003c\/strong\u003e\u003cbr\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBinder:\u003c\/strong\u003e\u003cbr\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eLCT Shielding:\u003c\/strong\u003e\u003cbr\u003e5 mils tape shield\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cbr\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003eSOLONON Low Smoke Zero Halogen (LSZH) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 14 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 2\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.070\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 45\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e 0.349\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e  26\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 68\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e  1.4\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e15\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e15\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 15\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55699466125681,"sku":"NNC11113","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/7_6bb33ec7-434e-4aa7-be39-bd428c65c616.png?v=1754555546"},{"product_id":"14-awg-3c-copper-fr-xlpe-lct-shielded-lszh-jacket-control-cable-600v","title":"14 AWG 3C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85045_1_1.pdf?v=1754555155\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 3C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Flame Retardant Cross Linked Polyethylene (FR-XLPE) Insulation Shielded SOLONON Low Smoke Zero Halogen (LSZH) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e14 AWG 3C Multi-Conductor CU Control Cable, 600V FR-XLPE LSZH Cable, Fire-Resistant Control Cable, XLPE Jacket Control Cable, 14 AWG 3C LSZH Control Cable, CU 600V Control Cable, Fire Retardant XLPE Cable, 14 AWG 3C Low Smoke Zero Halogen Cable, Multi-Conductor Control Wire, 14 AWG 3C 600V LSZH Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFiller:\u003c\/strong\u003e\u003cbr\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBinder:\u003c\/strong\u003e\u003cbr\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eLCT Shielding:\u003c\/strong\u003e\u003cbr\u003e5 mils tape shield\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cbr\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003eSOLONON Low Smoke Zero Halogen (LSZH) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 14 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 3\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.070\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 45\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e  0.370\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e  38\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 87\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e  1.5\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e15\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e15\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 15\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55699468157297,"sku":"NNC11114","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/7_6bb33ec7-434e-4aa7-be39-bd428c65c616.png?v=1754555546"},{"product_id":"14-awg-4c-copper-fr-xlpe-lct-shielded-lszh-jacket-control-cable-600v","title":"14 AWG 4C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85045_1_1.pdf?v=1754555155\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 4C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Flame Retardant Cross Linked Polyethylene (FR-XLPE) Insulation Shielded SOLONON Low Smoke Zero Halogen (LSZH) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e14 AWG 4C Multi-Conductor CU Control Cable, 600V FR-XLPE LSZH Cable, Fire-Resistant Control Cable, XLPE Jacket Control Cable, 14 AWG 4C LSZH Control Cable, CU 600V Control Cable, Fire Retardant XLPE Cable, 14 AWG 4C Low Smoke Zero Halogen Cable, Multi-Conductor Control Wire, 14 AWG 4C 600V LSZH Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFiller:\u003c\/strong\u003e\u003cbr\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBinder:\u003c\/strong\u003e\u003cbr\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eLCT Shielding:\u003c\/strong\u003e\u003cbr\u003e5 mils tape shield\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cbr\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003eSOLONON Low Smoke Zero Halogen (LSZH) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 14 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 4\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.070\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 45\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e   0.403\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e  51\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 109\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e  1.6\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e14\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e15\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 15\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55699478905201,"sku":"NNC11115","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/7_6bb33ec7-434e-4aa7-be39-bd428c65c616.png?v=1754555546"},{"product_id":"14-awg-5c-copper-fr-xlpe-lct-shielded-lszh-jacket-control-cable-600v","title":"14 AWG 5C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85045_1_1.pdf?v=1754555155\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 5C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Flame Retardant Cross Linked Polyethylene (FR-XLPE) Insulation Shielded SOLONON Low Smoke Zero Halogen (LSZH) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e14 AWG 5C Multi-Conductor CU Control Cable, 600V FR-XLPE LSZH Cable, Fire-Resistant Control Cable, XLPE Jacket Control Cable, 14 AWG 5C LSZH Control Cable, CU 600V Control Cable, Fire Retardant XLPE Cable, 14 AWG 5C Low Smoke Zero Halogen Cable, Multi-Conductor Control Wire, 14 AWG 5C 600V LSZH Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFiller:\u003c\/strong\u003e\u003cbr\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBinder:\u003c\/strong\u003e\u003cbr\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eLCT Shielding:\u003c\/strong\u003e\u003cbr\u003e5 mils tape shield\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cbr\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003eSOLONON Low Smoke Zero Halogen (LSZH) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 14 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 5\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.070\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 45\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e 0.440\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e  64\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  132\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 1.8\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e14\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e15\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 15\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55699483689329,"sku":"NNC11116","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/7_6bb33ec7-434e-4aa7-be39-bd428c65c616.png?v=1754555546"},{"product_id":"14-awg-6c-copper-fr-xlpe-lct-shielded-lszh-jacket-control-cable-600v","title":"14 AWG 6C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85045_1_1.pdf?v=1754555155\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 6C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Flame Retardant Cross Linked Polyethylene (FR-XLPE) Insulation Shielded SOLONON Low Smoke Zero Halogen (LSZH) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e14 AWG 6C Multi-Conductor CU Control Cable, 600V FR-XLPE LSZH Cable, Fire-Resistant Control Cable, XLPE Jacket Control Cable, 14 AWG 6C LSZH Control Cable, CU 600V Control Cable, Fire Retardant XLPE Cable, 14 AWG 6C Low Smoke Zero Halogen Cable, Multi-Conductor Control Wire, 14 AWG 6C 600V LSZH Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFiller:\u003c\/strong\u003e\u003cbr\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBinder:\u003c\/strong\u003e\u003cbr\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eLCT Shielding:\u003c\/strong\u003e\u003cbr\u003e5 mils tape shield\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cbr\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003eSOLONON Low Smoke Zero Halogen (LSZH) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 14 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 6\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.070\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 45\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e 0.479\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e  77\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  155\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 1.9\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e14\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e15\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 15\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55699488637297,"sku":"NNC11117","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/7_6bb33ec7-434e-4aa7-be39-bd428c65c616.png?v=1754555546"},{"product_id":"14-awg-7c-copper-fr-xlpe-lct-shielded-lszh-jacket-control-cable-600v","title":"14 AWG 7C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85045_1_1.pdf?v=1754555155\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 7C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Flame Retardant Cross Linked Polyethylene (FR-XLPE) Insulation Shielded SOLONON Low Smoke Zero Halogen (LSZH) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e14 AWG 7C Multi-Conductor CU Control Cable, 600V FR-XLPE LSZH Cable, Fire-Resistant Control Cable, XLPE Jacket Control Cable, 14 AWG 7C LSZH Control Cable, CU 600V Control Cable, Fire Retardant XLPE Cable, 14 AWG 7C Low Smoke Zero Halogen Cable, Multi-Conductor Control Wire, 14 AWG 7C 600V LSZH Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFiller:\u003c\/strong\u003e\u003cbr\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBinder:\u003c\/strong\u003e\u003cbr\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eLCT Shielding:\u003c\/strong\u003e\u003cbr\u003e5 mils tape shield\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cbr\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003eSOLONON Low Smoke Zero Halogen (LSZH) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 14 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 7\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.070\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 45\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e 0.479\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e  90\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  171\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 1.9\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e12\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e15\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 15\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55699493323121,"sku":"NNC11118","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/7_6bb33ec7-434e-4aa7-be39-bd428c65c616.png?v=1754555546"},{"product_id":"14-awg-8c-copper-fr-xlpe-lct-shielded-lszh-jacket-control-cable-600v","title":"14 AWG 8C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85045_1_1.pdf?v=1754555155\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 8C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Flame Retardant Cross Linked Polyethylene (FR-XLPE) Insulation Shielded SOLONON Low Smoke Zero Halogen (LSZH) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e14 AWG 8C Multi-Conductor CU Control Cable, 600V FR-XLPE LSZH Cable, Fire-Resistant Control Cable, XLPE Jacket Control Cable, 14 AWG 8C LSZH Control Cable, CU 600V Control Cable, Fire Retardant XLPE Cable, 14 AWG 8C Low Smoke Zero Halogen Cable, Multi-Conductor Control Wire, 14 AWG 8C 600V LSZH Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFiller:\u003c\/strong\u003e\u003cbr\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBinder:\u003c\/strong\u003e\u003cbr\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eLCT Shielding:\u003c\/strong\u003e\u003cbr\u003e5 mils tape shield\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cbr\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003eSOLONON Low Smoke Zero Halogen (LSZH) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 14 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 8\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.070\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 45\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e  0.519\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e  102\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e   195\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 2.1\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e12\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e15\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 15\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55699498402161,"sku":"NNC11119","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/7_6bb33ec7-434e-4aa7-be39-bd428c65c616.png?v=1754555546"},{"product_id":"14-awg-9c-copper-fr-xlpe-lct-shielded-lszh-jacket-control-cable-600v","title":"14 AWG 9C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85045_1_1.pdf?v=1754555155\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 9C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Flame Retardant Cross Linked Polyethylene (FR-XLPE) Insulation Shielded SOLONON Low Smoke Zero Halogen (LSZH) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e14 AWG 9C Multi-Conductor CU Control Cable, 600V FR-XLPE LSZH Cable, Fire-Resistant Control Cable, XLPE Jacket Control Cable, 14 AWG 9C LSZH Control Cable, CU 600V Control Cable, Fire Retardant XLPE Cable, 14 AWG 9C Low Smoke Zero Halogen Cable, Multi-Conductor Control Wire, 14 AWG 9C 600V LSZH Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFiller:\u003c\/strong\u003e\u003cbr\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBinder:\u003c\/strong\u003e\u003cbr\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eLCT Shielding:\u003c\/strong\u003e\u003cbr\u003e5 mils tape shield\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cbr\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003eSOLONON Low Smoke Zero Halogen (LSZH) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 14 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 9\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.070\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 60\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e  0.588\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e 115\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 236\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 2.4\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e12\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e15\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 15\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55699507478897,"sku":"NNC11120","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/7_6bb33ec7-434e-4aa7-be39-bd428c65c616.png?v=1754555546"},{"product_id":"14-awg-10c-copper-fr-xlpe-lct-shielded-lszh-jacket-control-cable-600v","title":"14 AWG 10C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85045_1_1.pdf?v=1754555155\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 10C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Flame Retardant Cross Linked Polyethylene (FR-XLPE) Insulation Shielded SOLONON Low Smoke Zero Halogen (LSZH) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e14 AWG 10C Multi-Conductor CU Control Cable, 600V FR-XLPE LSZH Cable, Fire-Resistant Control Cable, XLPE Jacket Control Cable, 14 AWG 10C LSZH Control Cable, CU 600V Control Cable, Fire Retardant XLPE Cable, 14 AWG 10C Low Smoke Zero Halogen Cable, Multi-Conductor Control Wire, 14 AWG 10C 600V LSZH Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFiller:\u003c\/strong\u003e\u003cbr\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBinder:\u003c\/strong\u003e\u003cbr\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eLCT Shielding:\u003c\/strong\u003e\u003cbr\u003e5 mils tape shield\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cbr\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003eSOLONON Low Smoke Zero Halogen (LSZH) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 14 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 10\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.070\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 60\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e  0.638\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e  128\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 266\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 2.6\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e9\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 11\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 12\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55699515867505,"sku":"NNC11121","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/7_6bb33ec7-434e-4aa7-be39-bd428c65c616.png?v=1754555546"},{"product_id":"14-awg-12c-copper-fr-xlpe-lct-shielded-lszh-jacket-control-cable-600v","title":"14 AWG 12C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85045_1_1.pdf?v=1754555155\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 12C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Flame Retardant Cross Linked Polyethylene (FR-XLPE) Insulation Shielded SOLONON Low Smoke Zero Halogen (LSZH) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e14 AWG 12C Multi-Conductor CU Control Cable, 600V FR-XLPE LSZH Cable, Fire-Resistant Control Cable, XLPE Jacket Control Cable, 14 AWG 12C LSZH Control Cable, CU 600V Control Cable, Fire Retardant XLPE Cable, 14 AWG 12C Low Smoke Zero Halogen Cable, Multi-Conductor Control Wire, 14 AWG 12C 600V LSZH Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFiller:\u003c\/strong\u003e\u003cbr\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBinder:\u003c\/strong\u003e\u003cbr\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eLCT Shielding:\u003c\/strong\u003e\u003cbr\u003e5 mils tape shield\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cbr\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003eSOLONON Low Smoke Zero Halogen (LSZH) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 14 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 12\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.070\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 60\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e  0.659\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e  154\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 303\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 2.6\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e9\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 11\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 12\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55699527369073,"sku":"NNC11122","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/7_6bb33ec7-434e-4aa7-be39-bd428c65c616.png?v=1754555546"},{"product_id":"14-awg-15c-copper-fr-xlpe-lct-shielded-lszh-jacket-control-cable-600v","title":"14 AWG 15C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85045_1_1.pdf?v=1754555155\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 15C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Flame Retardant Cross Linked Polyethylene (FR-XLPE) Insulation Shielded SOLONON Low Smoke Zero Halogen (LSZH) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e14 AWG 15C Multi-Conductor CU Control Cable, 600V FR-XLPE LSZH Cable, Fire-Resistant Control Cable, XLPE Jacket Control Cable, 14 AWG 15C LSZH Control Cable, CU 600V Control Cable, Fire Retardant XLPE Cable, 14 AWG 15C Low Smoke Zero Halogen Cable, Multi-Conductor Control Wire, 14 AWG 15C 600V LSZH Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFiller:\u003c\/strong\u003e\u003cbr\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBinder:\u003c\/strong\u003e\u003cbr\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eLCT Shielding:\u003c\/strong\u003e\u003cbr\u003e5 mils tape shield\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cbr\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003eSOLONON Low Smoke Zero Halogen (LSZH) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 14 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 15\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.070\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 60\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e   0.730\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e  192\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  371\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 2.9\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e9\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 11\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 12\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55699541754225,"sku":"NNC11123","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/7_6bb33ec7-434e-4aa7-be39-bd428c65c616.png?v=1754555546"},{"product_id":"14-awg-19c-copper-fr-xlpe-lct-shielded-lszh-jacket-control-cable-600v","title":"14 AWG 19C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85045_1_1.pdf?v=1754555155\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 19C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Flame Retardant Cross Linked Polyethylene (FR-XLPE) Insulation Shielded SOLONON Low Smoke Zero Halogen (LSZH) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e14 AWG 19C Multi-Conductor CU Control Cable, 600V FR-XLPE LSZH Cable, Fire-Resistant Control Cable, XLPE Jacket Control Cable, 14 AWG 19C LSZH Control Cable, CU 600V Control Cable, Fire Retardant XLPE Cable, 14 AWG 19C Low Smoke Zero Halogen Cable, Multi-Conductor Control Wire, 14 AWG 19C 600V LSZH Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFiller:\u003c\/strong\u003e\u003cbr\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBinder:\u003c\/strong\u003e\u003cbr\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eLCT Shielding:\u003c\/strong\u003e\u003cbr\u003e5 mils tape shield\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cbr\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003eSOLONON Low Smoke Zero Halogen (LSZH) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 14 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.070\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 60\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e 0.768\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e  243\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  446\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 3.1\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e9\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 11\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 12\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55699552502129,"sku":"NNC11124","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/7_6bb33ec7-434e-4aa7-be39-bd428c65c616.png?v=1754555546"},{"product_id":"14-awg-20c-copper-fr-xlpe-lct-shielded-lszh-jacket-control-cable-600v","title":"14 AWG 20C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85045_1_1.pdf?v=1754555155\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 20C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Flame Retardant Cross Linked Polyethylene (FR-XLPE) Insulation Shielded SOLONON Low Smoke Zero Halogen (LSZH) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e14 AWG 20C Multi-Conductor CU Control Cable, 600V FR-XLPE LSZH Cable, Fire-Resistant Control Cable, XLPE Jacket Control Cable, 14 AWG 20C LSZH Control Cable, CU 600V Control Cable, Fire Retardant XLPE Cable, 14 AWG 20C Low Smoke Zero Halogen Cable, Multi-Conductor Control Wire, 14 AWG 20C 600V LSZH Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFiller:\u003c\/strong\u003e\u003cbr\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBinder:\u003c\/strong\u003e\u003cbr\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eLCT Shielding:\u003c\/strong\u003e\u003cbr\u003e5 mils tape shield\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cbr\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003eSOLONON Low Smoke Zero Halogen (LSZH) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 14 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 20\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.070\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 60\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e 0.808\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e   256\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  475\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 3.2\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e9\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 11\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 12\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55699557482865,"sku":"NNC11125","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/7_6bb33ec7-434e-4aa7-be39-bd428c65c616.png?v=1754555546"},{"product_id":"14-awg-25c-copper-fr-xlpe-lct-shielded-lszh-jacket-control-cable-600v","title":"14 AWG 25C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85045_1_1.pdf?v=1754555155\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 25C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Flame Retardant Cross Linked Polyethylene (FR-XLPE) Insulation Shielded SOLONON Low Smoke Zero Halogen (LSZH) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e14 AWG 25C Multi-Conductor CU Control Cable, 600V FR-XLPE LSZH Cable, Fire-Resistant Control Cable, XLPE Jacket Control Cable, 14 AWG 25C LSZH Control Cable, CU 600V Control Cable, Fire Retardant XLPE Cable, 14 AWG 25C Low Smoke Zero Halogen Cable, Multi-Conductor Control Wire, 14 AWG 25C 600V LSZH Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFiller:\u003c\/strong\u003e\u003cbr\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBinder:\u003c\/strong\u003e\u003cbr\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eLCT Shielding:\u003c\/strong\u003e\u003cbr\u003e5 mils tape shield\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cbr\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003eSOLONON Low Smoke Zero Halogen (LSZH) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 14 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 25\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.070\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e  0.937\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e  320\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 619\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 3.7\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e 8\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  9\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 11\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55699563184497,"sku":"NNC11126","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/7_6bb33ec7-434e-4aa7-be39-bd428c65c616.png?v=1754555546"},{"product_id":"14-awg-30c-copper-fr-xlpe-lct-shielded-lszh-jacket-control-cable-600v","title":"14 AWG 30C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85045_1_1.pdf?v=1754555155\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 30C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Flame Retardant Cross Linked Polyethylene (FR-XLPE) Insulation Shielded SOLONON Low Smoke Zero Halogen (LSZH) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e14 AWG 30C Multi-Conductor CU Control Cable, 600V FR-XLPE LSZH Cable, Fire-Resistant Control Cable, XLPE Jacket Control Cable, 14 AWG 30C LSZH Control Cable, CU 600V Control Cable, Fire Retardant XLPE Cable, 14 AWG 30C Low Smoke Zero Halogen Cable, Multi-Conductor Control Wire, 14 AWG 30C 600V LSZH Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFiller:\u003c\/strong\u003e\u003cbr\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBinder:\u003c\/strong\u003e\u003cbr\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eLCT Shielding:\u003c\/strong\u003e\u003cbr\u003e5 mils tape shield\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cbr\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003eSOLONON Low Smoke Zero Halogen (LSZH) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 14 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.070\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e  0.991\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e  384\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 719\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 4.0\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e 8\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  9\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 11\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55699568230769,"sku":"NNC11127","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/7_6bb33ec7-434e-4aa7-be39-bd428c65c616.png?v=1754555546"},{"product_id":"14-awg-37c-copper-fr-xlpe-lct-shielded-lszh-jacket-control-cable-600v","title":"14 AWG 37C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85045_1_1.pdf?v=1754555155\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 37C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Flame Retardant Cross Linked Polyethylene (FR-XLPE) Insulation Shielded SOLONON Low Smoke Zero Halogen (LSZH) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e14 AWG 37C Multi-Conductor CU Control Cable, 600V FR-XLPE LSZH Cable, Fire-Resistant Control Cable, XLPE Jacket Control Cable, 14 AWG 37C LSZH Control Cable, CU 600V Control Cable, Fire Retardant XLPE Cable, 14 AWG 37C Low Smoke Zero Halogen Cable, Multi-Conductor Control Wire, 14 AWG 37C 600V LSZH Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFiller:\u003c\/strong\u003e\u003cbr\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBinder:\u003c\/strong\u003e\u003cbr\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eLCT Shielding:\u003c\/strong\u003e\u003cbr\u003e5 mils tape shield\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cbr\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003eSOLONON Low Smoke Zero Halogen (LSZH) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 14 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 37\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.070\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e  1.067\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e  474\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 862\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 5.3\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e7\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  8\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 10\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55699573408113,"sku":"NNC11128","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/7_6bb33ec7-434e-4aa7-be39-bd428c65c616.png?v=1754555546"},{"product_id":"12-awg-2c-copper-fr-xlpe-lct-shielded-lszh-jacket-control-cable-600v","title":"12 AWG 2C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85045_1_1.pdf?v=1754555155\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 2C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Flame Retardant Cross Linked Polyethylene (FR-XLPE) Insulation Shielded SOLONON Low Smoke Zero Halogen (LSZH) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e12 AWG 2C Multi-Conductor CU Control Cable, 600V FR-XLPE LSZH Cable, Fire-Resistant Control Cable, XLPE Jacket Control Cable, 12 AWG 2C LSZH Control Cable, CU 600V Control Cable, Fire Retardant XLPE Cable, 12 AWG 2C Low Smoke Zero Halogen Cable, Multi-Conductor Control Wire, 12 AWG 2C 600V LSZH Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFiller:\u003c\/strong\u003e\u003cbr\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBinder:\u003c\/strong\u003e\u003cbr\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eLCT Shielding:\u003c\/strong\u003e\u003cbr\u003e5 mils tape shield\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cbr\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003eSOLONON Low Smoke Zero Halogen (LSZH) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 12 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 2\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.087\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 45\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e  0.384\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e   41\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  90\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e  1.5\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e 20\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  20\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 20\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55699583664497,"sku":"NNC11129","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/7_6bb33ec7-434e-4aa7-be39-bd428c65c616.png?v=1754555546"},{"product_id":"12-awg-3c-copper-fr-xlpe-lct-shielded-lszh-jacket-control-cable-600v","title":"12 AWG 3C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85045_1_1.pdf?v=1754555155\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 3C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Flame Retardant Cross Linked Polyethylene (FR-XLPE) Insulation Shielded SOLONON Low Smoke Zero Halogen (LSZH) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e12 AWG 3C Multi-Conductor CU Control Cable, 600V FR-XLPE LSZH Cable, Fire-Resistant Control Cable, XLPE Jacket Control Cable, 12 AWG 3C LSZH Control Cable, CU 600V Control Cable, Fire Retardant XLPE Cable, 12 AWG 3C Low Smoke Zero Halogen Cable, Multi-Conductor Control Wire, 12 AWG 3C 600V LSZH Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFiller:\u003c\/strong\u003e\u003cbr\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBinder:\u003c\/strong\u003e\u003cbr\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eLCT Shielding:\u003c\/strong\u003e\u003cbr\u003e5 mils tape shield\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cbr\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003eSOLONON Low Smoke Zero Halogen (LSZH) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 12 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 3\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.087\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 45\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e  0.408\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e  61\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 118\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 1.6\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e 20\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  20\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 20\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55702568141169,"sku":"NNC11130","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/7_6bb33ec7-434e-4aa7-be39-bd428c65c616.png?v=1754555546"},{"product_id":"12-awg-4c-copper-fr-xlpe-lct-shielded-lszh-jacket-control-cable-600v","title":"12 AWG 4C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85045_1_1.pdf?v=1754555155\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 4C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Flame Retardant Cross Linked Polyethylene (FR-XLPE) Insulation Shielded SOLONON Low Smoke Zero Halogen (LSZH) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e12 AWG 4C Multi-Conductor CU Control Cable, 600V FR-XLPE LSZH Cable, Fire-Resistant Control Cable, XLPE Jacket Control Cable, 12 AWG 4C LSZH Control Cable, CU 600V Control Cable, Fire Retardant XLPE Cable, 12 AWG 4C Low Smoke Zero Halogen Cable, Multi-Conductor Control Wire, 12 AWG 4C 600V LSZH Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFiller:\u003c\/strong\u003e\u003cbr\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBinder:\u003c\/strong\u003e\u003cbr\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eLCT Shielding:\u003c\/strong\u003e\u003cbr\u003e5 mils tape shield\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cbr\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003eSOLONON Low Smoke Zero Halogen (LSZH) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 12 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 4\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.087\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 45\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e  0.445\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e  81\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 148\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 1.8\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e 16\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  20\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 20\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55702573678961,"sku":"NNC11131","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/7_6bb33ec7-434e-4aa7-be39-bd428c65c616.png?v=1754555546"},{"product_id":"12-awg-5c-copper-fr-xlpe-lct-shielded-lszh-jacket-control-cable-600v","title":"12 AWG 5C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85045_1_1.pdf?v=1754555155\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 5C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Flame Retardant Cross Linked Polyethylene (FR-XLPE) Insulation Shielded SOLONON Low Smoke Zero Halogen (LSZH) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e12 AWG 5C Multi-Conductor CU Control Cable, 600V FR-XLPE LSZH Cable, Fire-Resistant Control Cable, XLPE Jacket Control Cable, 12 AWG 5C LSZH Control Cable, CU 600V Control Cable, Fire Retardant XLPE Cable, 12 AWG 5C Low Smoke Zero Halogen Cable, Multi-Conductor Control Wire, 12 AWG 5C 600V LSZH Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFiller:\u003c\/strong\u003e\u003cbr\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBinder:\u003c\/strong\u003e\u003cbr\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eLCT Shielding:\u003c\/strong\u003e\u003cbr\u003e5 mils tape shield\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cbr\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003eSOLONON Low Smoke Zero Halogen (LSZH) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 12 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 5\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.087\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 45\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e  0.487\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e  102\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 181\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 1.9\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e 16\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  20\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 20\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55702574072177,"sku":"NNC11132","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/7_6bb33ec7-434e-4aa7-be39-bd428c65c616.png?v=1754555546"},{"product_id":"12-awg-6c-copper-fr-xlpe-lct-shielded-lszh-jacket-control-cable-600v","title":"12 AWG 6C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85045_1_1.pdf?v=1754555155\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 6C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Flame Retardant Cross Linked Polyethylene (FR-XLPE) Insulation Shielded SOLONON Low Smoke Zero Halogen (LSZH) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e12 AWG 6C Multi-Conductor CU Control Cable, 600V FR-XLPE LSZH Cable, Fire-Resistant Control Cable, XLPE Jacket Control Cable, 12 AWG 6C LSZH Control Cable, CU 600V Control Cable, Fire Retardant XLPE Cable, 12 AWG 6C Low Smoke Zero Halogen Cable, Multi-Conductor Control Wire, 12 AWG 6C 600V LSZH Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFiller:\u003c\/strong\u003e\u003cbr\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBinder:\u003c\/strong\u003e\u003cbr\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eLCT Shielding:\u003c\/strong\u003e\u003cbr\u003e5 mils tape shield\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cbr\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003eSOLONON Low Smoke Zero Halogen (LSZH) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 12 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 6\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.087\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 45\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e  0.532\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e   122\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 214\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 2.1\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e 16\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  20\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 20\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55702574268785,"sku":"NNC11133","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/7_6bb33ec7-434e-4aa7-be39-bd428c65c616.png?v=1754555546"},{"product_id":"12-awg-7c-copper-fr-xlpe-lct-shielded-lszh-jacket-control-cable-600v","title":"12 AWG 7C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85045_1_1.pdf?v=1754555155\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 7C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Flame Retardant Cross Linked Polyethylene (FR-XLPE) Insulation Shielded SOLONON Low Smoke Zero Halogen (LSZH) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e12 AWG 7C Multi-Conductor CU Control Cable, 600V FR-XLPE LSZH Cable, Fire-Resistant Control Cable, XLPE Jacket Control Cable, 12 AWG 7C LSZH Control Cable, CU 600V Control Cable, Fire Retardant XLPE Cable, 12 AWG 7C Low Smoke Zero Halogen Cable, Multi-Conductor Control Wire, 12 AWG 7C 600V LSZH Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFiller:\u003c\/strong\u003e\u003cbr\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBinder:\u003c\/strong\u003e\u003cbr\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eLCT Shielding:\u003c\/strong\u003e\u003cbr\u003e5 mils tape shield\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cbr\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003eSOLONON Low Smoke Zero Halogen (LSZH) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 12 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 7\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.087\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 45\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e  0.532\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e 143\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  237\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 2.1\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e 14\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 17\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 20\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55702578856305,"sku":"NNC11134","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/7_6bb33ec7-434e-4aa7-be39-bd428c65c616.png?v=1754555546"},{"product_id":"12-awg-8c-copper-fr-xlpe-lct-shielded-lszh-jacket-control-cable-600v","title":"12 AWG 8C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85045_1_1.pdf?v=1754555155\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 8C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Flame Retardant Cross Linked Polyethylene (FR-XLPE) Insulation Shielded SOLONON Low Smoke Zero Halogen (LSZH) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e12 AWG 8C Multi-Conductor CU Control Cable, 600V FR-XLPE LSZH Cable, Fire-Resistant Control Cable, XLPE Jacket Control Cable, 12 AWG 8C LSZH Control Cable, CU 600V Control Cable, Fire Retardant XLPE Cable, 12 AWG 8C Low Smoke Zero Halogen Cable, Multi-Conductor Control Wire, 12 AWG 8C 600V LSZH Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFiller:\u003c\/strong\u003e\u003cbr\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBinder:\u003c\/strong\u003e\u003cbr\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eLCT Shielding:\u003c\/strong\u003e\u003cbr\u003e5 mils tape shield\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cbr\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003eSOLONON Low Smoke Zero Halogen (LSZH) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 12 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 8\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.087\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 60\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e  0.607\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e 163\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  288\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 2.4\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e 14\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 17\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 20\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55702582821233,"sku":"NNC11135","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/7_6bb33ec7-434e-4aa7-be39-bd428c65c616.png?v=1754555546"},{"product_id":"12-awg-9c-copper-fr-xlpe-lct-shielded-lszh-jacket-control-cable-600v","title":"12 AWG 9C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85045_1_1.pdf?v=1754555155\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 9C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Flame Retardant Cross Linked Polyethylene (FR-XLPE) Insulation Shielded SOLONON Low Smoke Zero Halogen (LSZH) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e12 AWG 9C Multi-Conductor CU Control Cable, 600V FR-XLPE LSZH Cable, Fire-Resistant Control Cable, XLPE Jacket Control Cable, 12 AWG 9C LSZH Control Cable, CU 600V Control Cable, Fire Retardant XLPE Cable, 12 AWG 9C Low Smoke Zero Halogen Cable, Multi-Conductor Control Wire, 12 AWG 9C 600V LSZH Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFiller:\u003c\/strong\u003e\u003cbr\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBinder:\u003c\/strong\u003e\u003cbr\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eLCT Shielding:\u003c\/strong\u003e\u003cbr\u003e5 mils tape shield\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cbr\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003eSOLONON Low Smoke Zero Halogen (LSZH) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 12 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 9\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.087\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 60\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e  0.651\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e 183\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 324\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 2.6\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e 14\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 17\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 20\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55702585082225,"sku":"NNC11136","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/7_6bb33ec7-434e-4aa7-be39-bd428c65c616.png?v=1754555546"},{"product_id":"12-awg-10c-copper-fr-xlpe-lct-shielded-lszh-jacket-control-cable-600v","title":"12 AWG 10C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85045_1_1.pdf?v=1754555155\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 10C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Flame Retardant Cross Linked Polyethylene (FR-XLPE) Insulation Shielded SOLONON Low Smoke Zero Halogen (LSZH) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e12 AWG 10C Multi-Conductor CU Control Cable, 600V FR-XLPE LSZH Cable, Fire-Resistant Control Cable, XLPE Jacket Control Cable, 12 AWG 10C LSZH Control Cable, CU 600V Control Cable, Fire Retardant XLPE Cable, 12 AWG 10C Low Smoke Zero Halogen Cable, Multi-Conductor Control Wire, 12 AWG 10C 600V LSZH Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFiller:\u003c\/strong\u003e\u003cbr\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBinder:\u003c\/strong\u003e\u003cbr\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eLCT Shielding:\u003c\/strong\u003e\u003cbr\u003e5 mils tape shield\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cbr\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003eSOLONON Low Smoke Zero Halogen (LSZH) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 12 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 10\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.087\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 60\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e  0.709\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e 204\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  365\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 2.8\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e 10\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 12\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 15\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55702586524017,"sku":"NNC11137","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/7_6bb33ec7-434e-4aa7-be39-bd428c65c616.png?v=1754555546"},{"product_id":"12-awg-12c-copper-fr-xlpe-lct-shielded-lszh-jacket-control-cable-600v","title":"12 AWG 12C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85045_1_1.pdf?v=1754555155\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 12C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Flame Retardant Cross Linked Polyethylene (FR-XLPE) Insulation Shielded SOLONON Low Smoke Zero Halogen (LSZH) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e12 AWG 12C Multi-Conductor CU Control Cable, 600V FR-XLPE LSZH Cable, Fire-Resistant Control Cable, XLPE Jacket Control Cable, 12 AWG 12C LSZH Control Cable, CU 600V Control Cable, Fire Retardant XLPE Cable, 12 AWG 12C Low Smoke Zero Halogen Cable, Multi-Conductor Control Wire, 12 AWG 12C 600V LSZH Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFiller:\u003c\/strong\u003e\u003cbr\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBinder:\u003c\/strong\u003e\u003cbr\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eLCT Shielding:\u003c\/strong\u003e\u003cbr\u003e5 mils tape shield\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cbr\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003eSOLONON Low Smoke Zero Halogen (LSZH) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 12 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 12\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.087\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 60\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e  0.732\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e 244\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  419\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 2.9\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e 10\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 12\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 15\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55702593012081,"sku":"NNC662507","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/7_6bb33ec7-434e-4aa7-be39-bd428c65c616.png?v=1754555546"},{"product_id":"12-awg-15c-copper-fr-xlpe-lct-shielded-lszh-jacket-control-cable-600v","title":"12 AWG 15C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85045_1_1.pdf?v=1754555155\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 15C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Flame Retardant Cross Linked Polyethylene (FR-XLPE) Insulation Shielded SOLONON Low Smoke Zero Halogen (LSZH) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e12 AWG 15C Multi-Conductor CU Control Cable, 600V FR-XLPE LSZH Cable, Fire-Resistant Control Cable, XLPE Jacket Control Cable, 12 AWG 15C LSZH Control Cable, CU 600V Control Cable, Fire Retardant XLPE Cable, 12 AWG 15C Low Smoke Zero Halogen Cable, Multi-Conductor Control Wire, 12 AWG 15C 600V LSZH Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFiller:\u003c\/strong\u003e\u003cbr\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBinder:\u003c\/strong\u003e\u003cbr\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eLCT Shielding:\u003c\/strong\u003e\u003cbr\u003e5 mils tape shield\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cbr\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003eSOLONON Low Smoke Zero Halogen (LSZH) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 12 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 15\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.087\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 60\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e   0.813\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e  305\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  516\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 3.3\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e 10\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 12\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 15\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55702599991665,"sku":"NNC11139","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/7_6bb33ec7-434e-4aa7-be39-bd428c65c616.png?v=1754555546"},{"product_id":"12-awg-19c-copper-fr-xlpe-lct-shielded-lszh-jacket-control-cable-600v","title":"12 AWG 19C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85045_1_1.pdf?v=1754555155\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 19C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Flame Retardant Cross Linked Polyethylene (FR-XLPE) Insulation Shielded SOLONON Low Smoke Zero Halogen (LSZH) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e12 AWG 19C Multi-Conductor CU Control Cable, 600V FR-XLPE LSZH Cable, Fire-Resistant Control Cable, XLPE Jacket Control Cable, 12 AWG 19C LSZH Control Cable, CU 600V Control Cable, Fire Retardant XLPE Cable, 12 AWG 19C Low Smoke Zero Halogen Cable, Multi-Conductor Control Wire, 12 AWG 19C 600V LSZH Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFiller:\u003c\/strong\u003e\u003cbr\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBinder:\u003c\/strong\u003e\u003cbr\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eLCT Shielding:\u003c\/strong\u003e\u003cbr\u003e5 mils tape shield\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cbr\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003eSOLONON Low Smoke Zero Halogen (LSZH) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 12 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.087\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e  0.896\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e  387\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 657\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 3.6\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e 10\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 12\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 15\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55702609428849,"sku":"NNC11140","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/7_6bb33ec7-434e-4aa7-be39-bd428c65c616.png?v=1754555546"},{"product_id":"12-awg-20c-copper-fr-xlpe-lct-shielded-lszh-jacket-control-cable-600v","title":"12 AWG 20C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85045_1_1.pdf?v=1754555155\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 20C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Flame Retardant Cross Linked Polyethylene (FR-XLPE) Insulation Shielded SOLONON Low Smoke Zero Halogen (LSZH) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e12 AWG 20C Multi-Conductor CU Control Cable, 600V FR-XLPE LSZH Cable, Fire-Resistant Control Cable, XLPE Jacket Control Cable, 12 AWG 20C LSZH Control Cable, CU 600V Control Cable, Fire Retardant XLPE Cable, 12 AWG 20C Low Smoke Zero Halogen Cable, Multi-Conductor Control Wire, 12 AWG 20C 600V LSZH Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFiller:\u003c\/strong\u003e\u003cbr\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBinder:\u003c\/strong\u003e\u003cbr\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eLCT Shielding:\u003c\/strong\u003e\u003cbr\u003e5 mils tape shield\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cbr\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003eSOLONON Low Smoke Zero Halogen (LSZH) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 12 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 20\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.087\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e  0.942\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e  407\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 699\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 3.8\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e 10\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 12\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 15\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55702610805105,"sku":"NNC11141","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/7_6bb33ec7-434e-4aa7-be39-bd428c65c616.png?v=1754555546"},{"product_id":"12-awg-25c-copper-fr-xlpe-lct-shielded-lszh-jacket-control-cable-600v","title":"12 AWG 25C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85045_1_1.pdf?v=1754555155\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 25C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Flame Retardant Cross Linked Polyethylene (FR-XLPE) Insulation Shielded SOLONON Low Smoke Zero Halogen (LSZH) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e12 AWG 25C Multi-Conductor CU Control Cable, 600V FR-XLPE LSZH Cable, Fire-Resistant Control Cable, XLPE Jacket Control Cable, 12 AWG 25C LSZH Control Cable, CU 600V Control Cable, Fire Retardant XLPE Cable, 12 AWG 25C Low Smoke Zero Halogen Cable, Multi-Conductor Control Wire, 12 AWG 25C 600V LSZH Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFiller:\u003c\/strong\u003e\u003cbr\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBinder:\u003c\/strong\u003e\u003cbr\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eLCT Shielding:\u003c\/strong\u003e\u003cbr\u003e5 mils tape shield\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cbr\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003eSOLONON Low Smoke Zero Halogen (LSZH) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 12 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 25\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.087\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e 1.043\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e  509\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 860\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 5.2\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e 9\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  11\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  13\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55702625780081,"sku":"NNC11142","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/7_6bb33ec7-434e-4aa7-be39-bd428c65c616.png?v=1754555546"},{"product_id":"12-awg-30c-copper-fr-xlpe-lct-shielded-lszh-jacket-control-cable-600v","title":"12 AWG 30C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85045_1_1.pdf?v=1754555155\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 30C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Flame Retardant Cross Linked Polyethylene (FR-XLPE) Insulation Shielded SOLONON Low Smoke Zero Halogen (LSZH) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e12 AWG 30C Multi-Conductor CU Control Cable, 600V FR-XLPE LSZH Cable, Fire-Resistant Control Cable, XLPE Jacket Control Cable, 12 AWG 30C LSZH Control Cable, CU 600V Control Cable, Fire Retardant XLPE Cable, 12 AWG 30C Low Smoke Zero Halogen Cable, Multi-Conductor Control Wire, 12 AWG 30C 600V LSZH Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFiller:\u003c\/strong\u003e\u003cbr\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBinder:\u003c\/strong\u003e\u003cbr\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eLCT Shielding:\u003c\/strong\u003e\u003cbr\u003e5 mils tape shield\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cbr\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003eSOLONON Low Smoke Zero Halogen (LSZH) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 12 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.087\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e 1.104\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e  611\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 1005\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 5.5\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e 9\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  11\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  13\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55702670770545,"sku":"NNC11143","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/7_6bb33ec7-434e-4aa7-be39-bd428c65c616.png?v=1754555546"},{"product_id":"12-awg-37c-copper-fr-xlpe-lct-shielded-lszh-jacket-control-cable-600v","title":"12 AWG 37C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85045_1_1.pdf?v=1754555155\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 37C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Flame Retardant Cross Linked Polyethylene (FR-XLPE) Insulation Shielded SOLONON Low Smoke Zero Halogen (LSZH) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e12 AWG 37C Multi-Conductor CU Control Cable, 600V FR-XLPE LSZH Cable, Fire-Resistant Control Cable, XLPE Jacket Control Cable, 12 AWG 37C LSZH Control Cable, CU 600V Control Cable, Fire Retardant XLPE Cable, 12 AWG 37C Low Smoke Zero Halogen Cable, Multi-Conductor Control Wire, 12 AWG 37C 600V LSZH Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFiller:\u003c\/strong\u003e\u003cbr\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBinder:\u003c\/strong\u003e\u003cbr\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eLCT Shielding:\u003c\/strong\u003e\u003cbr\u003e5 mils tape shield\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cbr\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003eSOLONON Low Smoke Zero Halogen (LSZH) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 12 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 37\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.087\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e  1.191\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e  753\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 1211\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 6.0\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e 8\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  10\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  12\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55702692266353,"sku":"NNC11144","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/7_6bb33ec7-434e-4aa7-be39-bd428c65c616.png?v=1754555546"},{"product_id":"10-awg-2c-copper-fr-xlpe-lct-shielded-lszh-jacket-control-cable-600v","title":"10 AWG 2C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85045_1_1.pdf?v=1754555155\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e10 AWG 2C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Flame Retardant Cross Linked Polyethylene (FR-XLPE) Insulation Shielded SOLONON Low Smoke Zero Halogen (LSZH) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e10 AWG 2C Multi-Conductor CU Control Cable, 600V FR-XLPE LSZH Cable, Fire-Resistant Control Cable, XLPE Jacket Control Cable, 10 AWG 2C LSZH Control Cable, CU 600V Control Cable, Fire Retardant XLPE Cable, 10 AWG 2C Low Smoke Zero Halogen Cable, Multi-Conductor Control Wire, 10 AWG 2C 600V LSZH Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFiller:\u003c\/strong\u003e\u003cbr\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBinder:\u003c\/strong\u003e\u003cbr\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eLCT Shielding:\u003c\/strong\u003e\u003cbr\u003e5 mils tape shield\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cbr\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003eSOLONON Low Smoke Zero Halogen (LSZH) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 10 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 2\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.111\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 45\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e  0.431\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e  65\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 124\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 1.7\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e 30\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"5000 FT","offer_id":55740227453297,"sku":"NNC625554","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/7_6bb33ec7-434e-4aa7-be39-bd428c65c616.png?v=1754555546"},{"product_id":"10-awg-3c-copper-fr-xlpe-lct-shielded-lszh-jacket-control-cable-600v","title":"10 AWG 3C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85045_1_1.pdf?v=1754555155\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e10 AWG 3C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Flame Retardant Cross Linked Polyethylene (FR-XLPE) Insulation Shielded SOLONON Low Smoke Zero Halogen (LSZH) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e10 AWG 3C Multi-Conductor CU Control Cable, 600V FR-XLPE LSZH Cable, Fire-Resistant Control Cable, XLPE Jacket Control Cable, 10 AWG 3C LSZH Control Cable, CU 600V Control Cable, Fire Retardant XLPE Cable, 10 AWG 3C Low Smoke Zero Halogen Cable, Multi-Conductor Control Wire, 10 AWG 3C 600V LSZH Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFiller:\u003c\/strong\u003e\u003cbr\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBinder:\u003c\/strong\u003e\u003cbr\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eLCT Shielding:\u003c\/strong\u003e\u003cbr\u003e5 mils tape shield\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cbr\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003eSOLONON Low Smoke Zero Halogen (LSZH) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 10 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 3\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.111\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 45\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e  0.459\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e  97\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  165\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 1.8\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e 30\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"2000 FT","offer_id":55740241740145,"sku":"NNC662506","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/7_6bb33ec7-434e-4aa7-be39-bd428c65c616.png?v=1754555546"},{"product_id":"10-awg-4c-copper-fr-xlpe-lct-shielded-lszh-jacket-control-cable-600v","title":"10 AWG 4C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85045_1_1.pdf?v=1754555155\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e10 AWG 4C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Flame Retardant Cross Linked Polyethylene (FR-XLPE) Insulation Shielded SOLONON Low Smoke Zero Halogen (LSZH) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e10 AWG 4C Multi-Conductor CU Control Cable, 600V FR-XLPE LSZH Cable, Fire-Resistant Control Cable, XLPE Jacket Control Cable, 10 AWG 4C LSZH Control Cable, CU 600V Control Cable, Fire Retardant XLPE Cable, 10 AWG 4C Low Smoke Zero Halogen Cable, Multi-Conductor Control Wire, 10 AWG 4C 600V LSZH Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFiller:\u003c\/strong\u003e\u003cbr\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBinder:\u003c\/strong\u003e\u003cbr\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eLCT Shielding:\u003c\/strong\u003e\u003cbr\u003e5 mils tape shield\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cbr\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003eSOLONON Low Smoke Zero Halogen (LSZH) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 10 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 4\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.111\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 45\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e  0.502\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e 130\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 210\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 2.0\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e 24\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  28\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"2000 FT","offer_id":55740244197745,"sku":"NNC625561","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/7_6bb33ec7-434e-4aa7-be39-bd428c65c616.png?v=1754555546"},{"product_id":"10-awg-5c-copper-fr-xlpe-lct-shielded-lszh-jacket-control-cable-600v","title":"10 AWG 5C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85045_1_1.pdf?v=1754555155\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e10 AWG 5C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Flame Retardant Cross Linked Polyethylene (FR-XLPE) Insulation Shielded SOLONON Low Smoke Zero Halogen (LSZH) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e10 AWG 5C Multi-Conductor CU Control Cable, 600V FR-XLPE LSZH Cable, Fire-Resistant Control Cable, XLPE Jacket Control Cable, 10 AWG 5C LSZH Control Cable, CU 600V Control Cable, Fire Retardant XLPE Cable, 10 AWG 5C Low Smoke Zero Halogen Cable, Multi-Conductor Control Wire, 10 AWG 5C 600V LSZH Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFiller:\u003c\/strong\u003e\u003cbr\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBinder:\u003c\/strong\u003e\u003cbr\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eLCT Shielding:\u003c\/strong\u003e\u003cbr\u003e5 mils tape shield\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cbr\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003eSOLONON Low Smoke Zero Halogen (LSZH) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 10 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 5\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.111\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 60\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e  0.581\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e  162\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 273\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 2.3\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e 24\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  28\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55702810329457,"sku":"NNC11148","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/7_6bb33ec7-434e-4aa7-be39-bd428c65c616.png?v=1754555546"},{"product_id":"10-awg-6c-copper-fr-xlpe-lct-shielded-lszh-jacket-control-cable-600v","title":"10 AWG 6C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85045_1_1.pdf?v=1754555155\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e10 AWG 6C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Flame Retardant Cross Linked Polyethylene (FR-XLPE) Insulation Shielded SOLONON Low Smoke Zero Halogen (LSZH) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e10 AWG 6C Multi-Conductor CU Control Cable, 600V FR-XLPE LSZH Cable, Fire-Resistant Control Cable, XLPE Jacket Control Cable, 10 AWG 6C LSZH Control Cable, CU 600V Control Cable, Fire Retardant XLPE Cable, 10 AWG 6C Low Smoke Zero Halogen Cable, Multi-Conductor Control Wire, 10 AWG 6C 600V LSZH Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFiller:\u003c\/strong\u003e\u003cbr\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBinder:\u003c\/strong\u003e\u003cbr\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eLCT Shielding:\u003c\/strong\u003e\u003cbr\u003e5 mils tape shield\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cbr\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003eSOLONON Low Smoke Zero Halogen (LSZH) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 10 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 6\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.111\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 60\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e  0.632\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e  194\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 323\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 2.5\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e 24\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  28\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55702891069809,"sku":"NNC11149","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/7_6bb33ec7-434e-4aa7-be39-bd428c65c616.png?v=1754555546"},{"product_id":"10-awg-7c-copper-fr-xlpe-lct-shielded-lszh-jacket-control-cable-600v","title":"10 AWG 7C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85045_1_1.pdf?v=1754555155\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e10 AWG 7C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Flame Retardant Cross Linked Polyethylene (FR-XLPE) Insulation Shielded SOLONON Low Smoke Zero Halogen (LSZH) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e10 AWG 7C Multi-Conductor CU Control Cable, 600V FR-XLPE LSZH Cable, Fire-Resistant Control Cable, XLPE Jacket Control Cable, 10 AWG 7C LSZH Control Cable, CU 600V Control Cable, Fire Retardant XLPE Cable, 10 AWG 7C Low Smoke Zero Halogen Cable, Multi-Conductor Control Wire, 10 AWG 7C 600V LSZH Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFiller:\u003c\/strong\u003e\u003cbr\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBinder:\u003c\/strong\u003e\u003cbr\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eLCT Shielding:\u003c\/strong\u003e\u003cbr\u003e5 mils tape shield\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cbr\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003eSOLONON Low Smoke Zero Halogen (LSZH) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 10 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 7\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.111\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 60\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e  0.632\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e  227\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  358\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 2.5\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e 21\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  24\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  28\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"5000 FT","offer_id":55740246196593,"sku":"NNC662504","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/7_6bb33ec7-434e-4aa7-be39-bd428c65c616.png?v=1754555546"},{"product_id":"10-awg-8c-copper-fr-xlpe-lct-shielded-lszh-jacket-control-cable-600v","title":"10 AWG 8C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85045_1_1.pdf?v=1754555155\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e10 AWG 8C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Flame Retardant Cross Linked Polyethylene (FR-XLPE) Insulation Shielded SOLONON Low Smoke Zero Halogen (LSZH) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e10 AWG 8C Multi-Conductor CU Control Cable, 600V FR-XLPE LSZH Cable, Fire-Resistant Control Cable, XLPE Jacket Control Cable, 10 AWG 8C LSZH Control Cable, CU 600V Control Cable, Fire Retardant XLPE Cable, 10 AWG 8C Low Smoke Zero Halogen Cable, Multi-Conductor Control Wire, 10 AWG 8C 600V LSZH Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFiller:\u003c\/strong\u003e\u003cbr\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBinder:\u003c\/strong\u003e\u003cbr\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eLCT Shielding:\u003c\/strong\u003e\u003cbr\u003e5 mils tape shield\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cbr\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003eSOLONON Low Smoke Zero Halogen (LSZH) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 10 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 8\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.111\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 60\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e  0.685\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e  259\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  410\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 2.7\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e 21\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  24\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  28\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55702945268081,"sku":"NNC11151","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/7_6bb33ec7-434e-4aa7-be39-bd428c65c616.png?v=1754555546"},{"product_id":"10-awg-9c-copper-fr-xlpe-lct-shielded-lszh-jacket-control-cable-600v","title":"10 AWG 9C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85045_1_1.pdf?v=1754555155\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e10 AWG 9C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Flame Retardant Cross Linked Polyethylene (FR-XLPE) Insulation Shielded SOLONON Low Smoke Zero Halogen (LSZH) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e10 AWG 9C Multi-Conductor CU Control Cable, 600V FR-XLPE LSZH Cable, Fire-Resistant Control Cable, XLPE Jacket Control Cable, 10 AWG 9C LSZH Control Cable, CU 600V Control Cable, Fire Retardant XLPE Cable, 10 AWG 9C Low Smoke Zero Halogen Cable, Multi-Conductor Control Wire, 10 AWG 9C 600V LSZH Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFiller:\u003c\/strong\u003e\u003cbr\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBinder:\u003c\/strong\u003e\u003cbr\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eLCT Shielding:\u003c\/strong\u003e\u003cbr\u003e5 mils tape shield\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cbr\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003eSOLONON Low Smoke Zero Halogen (LSZH) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 10 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 9\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.111\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 60\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e   0.736\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e  291\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  461\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 2.9\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e 21\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  24\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  28\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55702985605489,"sku":"NNC11152","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/7_6bb33ec7-434e-4aa7-be39-bd428c65c616.png?v=1754555546"},{"product_id":"10-awg-10c-copper-fr-xlpe-lct-shielded-lszh-jacket-control-cable-600v","title":"10 AWG 10C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85045_1_1.pdf?v=1754555155\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e10 AWG 10C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Flame Retardant Cross Linked Polyethylene (FR-XLPE) Insulation Shielded SOLONON Low Smoke Zero Halogen (LSZH) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e10 AWG 10C Multi-Conductor CU Control Cable, 600V FR-XLPE LSZH Cable, Fire-Resistant Control Cable, XLPE Jacket Control Cable, 10 AWG 10C LSZH Control Cable, CU 600V Control Cable, Fire Retardant XLPE Cable, 10 AWG 10C Low Smoke Zero Halogen Cable, Multi-Conductor Control Wire, 10 AWG 10C 600V LSZH Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFiller:\u003c\/strong\u003e\u003cbr\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBinder:\u003c\/strong\u003e\u003cbr\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eLCT Shielding:\u003c\/strong\u003e\u003cbr\u003e5 mils tape shield\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cbr\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003eSOLONON Low Smoke Zero Halogen (LSZH) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 10 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 10\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.111\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 60\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e 0.803\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e  324\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 519\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 3.2\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e  15\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  17\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  20\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55703034757489,"sku":"NNC11153","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/7_6bb33ec7-434e-4aa7-be39-bd428c65c616.png?v=1754555546"},{"product_id":"10-awg-12c-copper-fr-xlpe-lct-shielded-lszh-jacket-control-cable-600v","title":"10 AWG 12C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85045_1_1.pdf?v=1754555155\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e10 AWG 12C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Flame Retardant Cross Linked Polyethylene (FR-XLPE) Insulation Shielded SOLONON Low Smoke Zero Halogen (LSZH) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e10 AWG 12C Multi-Conductor CU Control Cable, 600V FR-XLPE LSZH Cable, Fire-Resistant Control Cable, XLPE Jacket Control Cable, 10 AWG 12C LSZH Control Cable, CU 600V Control Cable, Fire Retardant XLPE Cable, 10 AWG 12C Low Smoke Zero Halogen Cable, Multi-Conductor Control Wire, 10 AWG 12C 600V LSZH Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFiller:\u003c\/strong\u003e\u003cbr\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBinder:\u003c\/strong\u003e\u003cbr\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eLCT Shielding:\u003c\/strong\u003e\u003cbr\u003e5 mils tape shield\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cbr\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003eSOLONON Low Smoke Zero Halogen (LSZH) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 10 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 12\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.111\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 60\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e  0.830\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e  389\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  600\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 3.3\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e  15\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  17\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  20\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"2000 FT","offer_id":55740257960305,"sku":"NNC625559","price":0.0,"currency_code":"USD","in_stock":true},{"title":"2500 FT","offer_id":55740257993073,"sku":"NNC625560","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/7_6bb33ec7-434e-4aa7-be39-bd428c65c616.png?v=1754555546"},{"product_id":"10-awg-15c-copper-fr-xlpe-lct-shielded-lszh-jacket-control-cable-600v","title":"10 AWG 15C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85045_1_1.pdf?v=1754555155\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e10 AWG 15C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Flame Retardant Cross Linked Polyethylene (FR-XLPE) Insulation Shielded SOLONON Low Smoke Zero Halogen (LSZH) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e10 AWG 15C Multi-Conductor CU Control Cable, 600V FR-XLPE LSZH Cable, Fire-Resistant Control Cable, XLPE Jacket Control Cable, 10 AWG 15C LSZH Control Cable, CU 600V Control Cable, Fire Retardant XLPE Cable, 10 AWG 15C Low Smoke Zero Halogen Cable, Multi-Conductor Control Wire, 10 AWG 15C 600V LSZH Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFiller:\u003c\/strong\u003e\u003cbr\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBinder:\u003c\/strong\u003e\u003cbr\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eLCT Shielding:\u003c\/strong\u003e\u003cbr\u003e5 mils tape shield\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cbr\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003eSOLONON Low Smoke Zero Halogen (LSZH) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 10 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 15\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.111\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e  0.964\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e  486\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  777\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 3.9\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e  15\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  17\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  20\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55703162126705,"sku":"NNC11155","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/7_6bb33ec7-434e-4aa7-be39-bd428c65c616.png?v=1754555546"},{"product_id":"10-awg-19c-copper-fr-xlpe-lct-shielded-lszh-jacket-control-cable-600v","title":"10 AWG 19C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85045_1_1.pdf?v=1754555155\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e10 AWG 19C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Flame Retardant Cross Linked Polyethylene (FR-XLPE) Insulation Shielded SOLONON Low Smoke Zero Halogen (LSZH) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e10 AWG 19C Multi-Conductor CU Control Cable, 600V FR-XLPE LSZH Cable, Fire-Resistant Control Cable, XLPE Jacket Control Cable, 10 AWG 19C LSZH Control Cable, CU 600V Control Cable, Fire Retardant XLPE Cable, 10 AWG 19C Low Smoke Zero Halogen Cable, Multi-Conductor Control Wire, 10 AWG 19C 600V LSZH Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFiller:\u003c\/strong\u003e\u003cbr\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBinder:\u003c\/strong\u003e\u003cbr\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eLCT Shielding:\u003c\/strong\u003e\u003cbr\u003e5 mils tape shield\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cbr\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003eSOLONON Low Smoke Zero Halogen (LSZH) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 10 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.111\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e 1.014\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e  615\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  941\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 5.1\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e  15\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  17\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  20\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55703175397745,"sku":"NNC11156","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/7_6bb33ec7-434e-4aa7-be39-bd428c65c616.png?v=1754555546"},{"product_id":"10-awg-20c-copper-fr-xlpe-lct-shielded-lszh-jacket-control-cable-600v","title":"10 AWG 20C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85045_1_1.pdf?v=1754555155\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e10 AWG 20C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Flame Retardant Cross Linked Polyethylene (FR-XLPE) Insulation Shielded SOLONON Low Smoke Zero Halogen (LSZH) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e10 AWG 20C Multi-Conductor CU Control Cable, 600V FR-XLPE LSZH Cable, Fire-Resistant Control Cable, XLPE Jacket Control Cable, 10 AWG 20C LSZH Control Cable, CU 600V Control Cable, Fire Retardant XLPE Cable, 10 AWG 20C Low Smoke Zero Halogen Cable, Multi-Conductor Control Wire, 10 AWG 20C 600V LSZH Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFiller:\u003c\/strong\u003e\u003cbr\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBinder:\u003c\/strong\u003e\u003cbr\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eLCT Shielding:\u003c\/strong\u003e\u003cbr\u003e5 mils tape shield\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cbr\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003eSOLONON Low Smoke Zero Halogen (LSZH) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 10 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 20\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.111\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e  1.067\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e  648\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e  1001\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 5.3\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e  15\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  17\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  20\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55703290151281,"sku":"NNC11157","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/7_6bb33ec7-434e-4aa7-be39-bd428c65c616.png?v=1754555546"},{"product_id":"10-awg-25c-copper-fr-xlpe-lct-shielded-lszh-jacket-control-cable-600v","title":"10 AWG 25C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85045_1_1.pdf?v=1754555155\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e10 AWG 25C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Flame Retardant Cross Linked Polyethylene (FR-XLPE) Insulation Shielded SOLONON Low Smoke Zero Halogen (LSZH) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e10 AWG 25C Multi-Conductor CU Control Cable, 600V FR-XLPE LSZH Cable, Fire-Resistant Control Cable, XLPE Jacket Control Cable, 10 AWG 25C LSZH Control Cable, CU 600V Control Cable, Fire Retardant XLPE Cable, 10 AWG 25C Low Smoke Zero Halogen Cable, Multi-Conductor Control Wire, 10 AWG 25C 600V LSZH Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFiller:\u003c\/strong\u003e\u003cbr\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBinder:\u003c\/strong\u003e\u003cbr\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eLCT Shielding:\u003c\/strong\u003e\u003cbr\u003e5 mils tape shield\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cbr\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003eSOLONON Low Smoke Zero Halogen (LSZH) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 10 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 25\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.111\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e  1.184\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e  810\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 1236\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 5.9\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e  13\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 15\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 18\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55703328031089,"sku":"NNC11158","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/7_6bb33ec7-434e-4aa7-be39-bd428c65c616.png?v=1754555546"},{"product_id":"10-awg-30c-copper-fr-xlpe-lct-shielded-lszh-jacket-control-cable-600v","title":"10 AWG 30C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85045_1_1.pdf?v=1754555155\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e10 AWG 30C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Flame Retardant Cross Linked Polyethylene (FR-XLPE) Insulation Shielded SOLONON Low Smoke Zero Halogen (LSZH) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e10 AWG 30C Multi-Conductor CU Control Cable, 600V FR-XLPE LSZH Cable, Fire-Resistant Control Cable, XLPE Jacket Control Cable, 10 AWG 30C LSZH Control Cable, CU 600V Control Cable, Fire Retardant XLPE Cable, 10 AWG 30C Low Smoke Zero Halogen Cable, Multi-Conductor Control Wire, 10 AWG 30C 600V LSZH Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFiller:\u003c\/strong\u003e\u003cbr\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBinder:\u003c\/strong\u003e\u003cbr\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eLCT Shielding:\u003c\/strong\u003e\u003cbr\u003e5 mils tape shield\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cbr\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003eSOLONON Low Smoke Zero Halogen (LSZH) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 10 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.111\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e 1.254\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e  971\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 1450\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 6.3\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e  13\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 15\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 18\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55703331864945,"sku":"NNC11159","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/7_6bb33ec7-434e-4aa7-be39-bd428c65c616.png?v=1754555546"},{"product_id":"10-awg-37c-copper-fr-xlpe-lct-shielded-lszh-jacket-control-cable-600v","title":"10 AWG 37C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPEC85045_1_1.pdf?v=1754555155\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e10 AWG 37C Copper FR-XLPE LCT Shielded LSZH Jacket Control Cable 600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.\u003cbr\u003e\u003cbr\u003eControl Cable 600 Volt Copper Conductors, Flame Retardant Cross Linked Polyethylene (FR-XLPE) Insulation Shielded SOLONON Low Smoke Zero Halogen (LSZH) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e10 AWG 37C Multi-Conductor CU Control Cable, 600V FR-XLPE LSZH Cable, Fire-Resistant Control Cable, XLPE Jacket Control Cable, 10 AWG 37C LSZH Control Cable, CU 600V Control Cable, Fire Retardant XLPE Cable, 10 AWG 37C Low Smoke Zero Halogen Cable, Multi-Conductor Control Wire, 10 AWG 37C 600V LSZH Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Standard Specification for Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• UL 44 Thermoset-Insulated Wires and Cables\u003cbr\u003e• UL 1277 Electrical Power and Control Tray Cables\u003cbr\u003e• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003cbr\u003e• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2\u003cbr\u003e• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables\u003cbr\u003e• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003cbr\u003e• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu\/hr) and ICEA T-29-520 - (210,000 Btu\/hr)\u003cbr\u003e• VW-1 (Vertical-Wire) Flame Test\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eConductor:\u003cbr\u003e\u003c\/b\u003e7 strands class B compressed bare copper per ASTM B3 and ASTM B8\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFiller:\u003c\/strong\u003e\u003cbr\u003ePolypropylene filler on cables with 5 or less conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBinder:\u003c\/strong\u003e\u003cbr\u003ePolyester flat thread binder tape applied for cables with more than 5 conductors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eLCT Shielding:\u003c\/strong\u003e\u003cbr\u003e5 mils tape shield\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRip Chord:\u003c\/strong\u003e\u003cbr\u003eRip chord for ease of jacket removal\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003eSOLONON Low Smoke Zero Halogen (LSZH) Jacket\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 10 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Conductors:\u003c\/strong\u003e\u003cspan\u003e 37\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(inch):\u003c\/strong\u003e\u003cspan\u003e  0.111\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 30\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (Mil):\u003c\/strong\u003e\u003cspan\u003e 80\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approx. OD (In):\u003c\/strong\u003e\u003cspan\u003e  1.355\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Copper Weight (Lbs\/1000'Ft):\u003c\/strong\u003e  1198\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e\u003cspan\u003e 1755\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e\u003cspan\u003e 6.8\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 60°C (Amp):\u003c\/strong\u003e  12\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity At 75°C (Amp):\u003c\/strong\u003e\u003cspan\u003e  14\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity 90°C (Amp):\u003c\/strong\u003e\u003cspan\u003e 16\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55703341695345,"sku":"NNC11160","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/7_6bb33ec7-434e-4aa7-be39-bd428c65c616.png?v=1754555546"}],"url":"https:\/\/nassaunationalcable.com\/collections\/multi-conductor-copper-fr-xlpe-lct-shielded-lszh-jacket-control-cable-600v.oembed?page=2","provider":"NassauNationalCable","version":"1.0","type":"link"}