{"title":"Medium Voltage Power Cables","description":"\u003c!-- split --\u003e\n\u003cp\u003e\u003cspan style=\"font-size: x-large;\"\u003e\u003cstrong\u003eMedium Product Voltage FAQs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003eWhat insulation is Medium Voltage Power Cable?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMedium Voltage Power cables insulation are cross-linked polyethylene (XLP) that do qualify with ICEA standards, and also Ethylene propylene rubber (EPR) which also complies with ICEA standards. Ethylene propylene rubber (EPR) is the most commonly used type of insulation for Medium Voltage. XLP insulation was formerly the more popular version about 10 years ago but that was used but EPR is the mainstay of today’s medium voltage cable world. \u003cspan class=\"click-readmore\"\u003eRead More\u003c\/span\u003e\u003c\/p\u003e\u003cdiv id=\"book-cat\"\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eWhat are most common types of insulation for Medium Voltage Power Cables?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eMedium Voltage cable is most often shielded. In most cases its unshielded when 2,400V – 5,000V of EPR Insulation PVC or Cross-linked polyethylene (XLP). EPR insulation CPE, though in most circumstances it can have an insulation of a Low Smoke Zero Halogen LSZH. The Cross-linked polyethylene (XLP) wire which of course would also be ICEA S-97-682 standards, and has a semi-conducting insulation shield.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003eWhat’s an examples of Medium Voltage Power Cable value advantage?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHigher voltage powers intensive voltage applications are Medium Voltage’s most commonly used type of wire. With Medium Voltage one gets a wire of 2,400V with the insulation level 133 percent.  Or possible a 5,000V UL Type MV-90 Dry, 90°C. Medium Voltage also has a 15,000V UL wire which ranges from -90, 90°C. The 25,000 \/ 35,000 volts wire UL Type MV ranges within temperatures of -105, 105°C.  The standard today is 105C.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003eWhat’s an example of Medium Voltage Power Cable Type Marking?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIdeally what is printed right on the cables and wires is the type of wire, size of wire, and also insulation, and jacket. For example : \u003cem\u003e5KV\/8KV UL Type MV-105, 105°C Single Conductor, Shielded, EPR Insulation, PVC Jacket 5KV 133%, 8KV 100% Insulation Level Copper Conductor.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003eWhat is a type of jacket do Medium Voltage Power Cables have?  \u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eChlorosulfonated polyethylene (CSPE\/Hypalon) per ICEA standards. Also Medium voltage holds Sunlight-resistant CPE per ICEA S-97-682 and UL Standard 1072 jackets. Also a few jackets that hold Cross-linked polyethylene (XLP) in qualification with ICEA standards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003eHow can I customize my Medium Voltage Power Cable?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUpon request, one can ask for the exact specifications one needs or is required to have for a certain use.   Ask the seller for a customized cable or wire. It does depend on the type of wire but it is almost always possible for one to request a certain type or gauge wire, than we can offer the exact cable one needs but it really depends on the gauge and amount and what the factory is running at that time. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003eWhat are other common types Medium Voltage Power Cable and cable and what kinds of applications are they used for?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMedium Voltage Power wire is suitable for all uses of chemical plants, refineries, steel mills, industrial plants, commercial buildings, utility substations and generating stations. It can also be used for generators and with motor and batteries as its main applications. Its portability makes it very easy to use on mobile equipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003eWhat are some specifications and standards I should consider when choosing Medium Voltage Power Cable?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Medium Voltage Power cable meets standards and regulations of the, ICEA S-96-659, UL Standard 1072, NEMA WC 71, AEIC CS8, Federal Specification J-C-30B.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003eWhat gauges sizes and strandings are available for Medium Voltage Power Cable?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Medium Voltage Power cable comes in sizes mainly through 8 AWG – 1000 MCM. Though many Medium Voltage wires can also only go through 2 AWG – 500 MCM. Medium Voltage cables strandings vary based on the gauge examples of strandings are 7, 19, 37, and 61; the bigger the size the more strandings a wire holds.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e   I.E Gauges + Strandings:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e8\/7 = Gauge size 8, Stranding 7\u003c\/li\u003e\n\u003cli\u003e1\/0-19 = Gauge size 1\/0,  Stranding 19\u003c\/li\u003e\n\u003cli\u003e350\/37 = Gauge size 350, Stranding 37\u003c\/li\u003e\n\u003cli\u003e1000\/61 = Gauge size 1000, Stranding 61\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003eWhat voltage rankings are available for Medium Voltage Wires?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor Medium Voltage cables you have available voltages of 2,400 Volts, 5,000 Volts, 8,000 Volts, 15,000 Volts, 25,000 Volts, and also offered in 35,000 Volts.  These certain voltage ratings are suitable for all uses in power circuits, after installed in open air, conduit, duct, or direct buried to the ground, and appropriate for all climate situations, in wet and dry locations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003eHow many conductors does Medium Voltage Cables come in? \u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable standard for Medium Voltage wires are single conductor of 2,400V, 5,000V, 8,000V, 15,000V, also 24,000, and 35,000V wires. Though you have the option of three conductor of Medium Voltage wires for cables of the 2,400V, 5,000V, and 8,000V with an over all PVC Jacket encompassing all of the wires. \u003c\/p\u003e\n\u003cspan class=\"click-readless\"\u003eRead Less\u003c\/span\u003e\n\u003c\/div\u003e","products":[{"product_id":"mv105-or-mv90-non-shielded-xlp-133-insulation-copper-cable-2-4kv","title":"MV105 OR MV90 Non-Shielded XLP 133% Insulation Copper Cable 2.4KV","description":"\u003cp\u003e[short] \u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003eMV105 OR MV90 Non-Shielded XLP 133% Insulation Copper Cable 2.4KV\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eApplications:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe mv105 or mv90 copper cable is an electrical wire used for power circuits up to 5,000 Volts when fixed in open air, conduit, or duct; in applications such as chemical plants, refineries, steel mills, industrial plants, commercial buildings, utility substations, and generating stations. The National Electric Code accepts this electrical cable for uses within 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eAlso Known As:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eMedium voltage power cables, mv power cable, mv105 cable, mv90, mv105.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eStandards:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eICEA S-96-659\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eUL Standard 1072\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eNEMA WC 71\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eConstruction\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eConductors:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe conductor is soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed), or ASTM B-496 (compact), with a semi-conducting conductor shield.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eInsulation:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eIt has cross-linked polyethylene (XLP) insulation. The conductors are normally cabled together with XLP insulated aluminum ground or bare copper ground and covered with reinforced binder tape. XLP insulation is tough and resistant to impact, abrasion, chemicals, acids, oils, industrial solvents, and changes in weather.\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eMV105 OR MV90 Non Shielded XLP 133% Insulation Copper Power Cable 5Kv\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eBeyond any reasonable doubt, the cable is proven to be sturdy and reliable. It has greater convenience and high performance, due to its ease of installation. A cable which is qualified for use in very strenuous and demanding conditions and still guarantees you an everlasting service in your system. This is a cable worth considering.\u003c\/p\u003e\n\u003cp\u003eLet us talk about the spectacular features of this cable.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cb\u003eConductor\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBoth MV105 and MV90 cables are made from copper conductors. The \u003ca href=\"https:\/\/www.nassaunationalcable.com\/wire-and-cable\/copper\/bare.html\"\u003ecopper conductor\u003c\/a\u003e used is soft and annealed. Besides it is bare, that is why the cable is called unshielded. Class B of the conductor used is stranded and compressed according to the provisions of ASTM B-8 or compacted as per the ASTM B-496. This conductor has also a semi-conductor shield which helps to reinforce its efficiency and strength.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cb\u003eInsulation\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eTo make the right choice of a cable during your purchase then you should as well check keenly the insulation features of that particular cable. A cable without good and sturdy insulation is destined to ruin your electrical connection. This brand of Nassau National Cable products has a cross-linked polyethylene insulation system. This insulation is designed according to the ICEA regulations.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eApplications\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eKnowing where and how to use this cable is extremely vital. Now as I mentioned earlier, load size resonates directly to the type and size of cable to use. This cable is used in power circuits where the voltage rates up to 5 Kilo volts. It is appropriate for installation in open air, conduit and duct installations.\u003c\/p\u003e\n\u003cp\u003eThis power cable has been applied in various systems in chemical plants, various industrial plants, steel mills, refineries, commercial buildings, utility substations and in generator stations. This cable has been tested and proved to work efficiently.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e Operation\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe National Electric Code, which is a very renowned and accepted standardization body, has approved this cable to be used within 90 degrees Celsius. It can however be used in 130 degrees Celsius emergency overloaded conditions. During a short circuit conditions, the cable can tolerate a temperature of 250 degrees Celsius.\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cstrong\u003eQuestion and Answer:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eFrequently Asked Questions - MV105 OR MV90 NON SHIELDED EPR HYPALON HEAVY WALL 133% COPPER CABLE 2.4kV-5kV and MV105 OR MV90 NON SHIELDED XLP 133% INSULATION COPPER CABLE 5KV\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003eWhat are the specific applications of MV105 or MV90 Non Shielded EPR Hypalon Heavy Wall 133% Copper 2.4kV-5kV Cables and MV105 or MV90 Non Shielded XLP 133% Insulation Copper cables 5kV?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMV105 or MV90 Non Shielded EPR Hypalon Heavy Wall 133% Copper cable 2.4kV-5kV Cables are suitable for corrosive environments in power circuits up to 2000V which are installed in open air, conduit \u0026amp; duct; cable tray when CT rated, in wet and dry conditions. These power cables are appropriate for chemical plants, refineries, steel mills, industrial plants, commercial buildings, utility substations and general stations.\u003c\/p\u003e\n\u003cp\u003eMV105 or MV90 Non Shielded XLP 133% Insulation Copper cables 5kV also are used in similar situations, just that it can be used in power circuits up to 5000V.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003eWhat type of conductor is used for MV105 or MV90 Non Shielded EPR Hypalon Heavy Wall 133% Copper 2.4kV-5kV Cables and MV105 or MV90 Non Shielded XLP 133% Insulation Copper cables 5kV?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe power cables have a semi-conducting conductor shield of soft bare annealed copper which qualify the ASTM B-3. It also has Class B stranding as per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003eWhat is the insulation used for MV105 or MV90 Non Shielded EPR Hypalon Heavy Wall 133% Copper 2.4kV-5kV Cables and MV105 or MV90 Non Shielded XLP 133% Insulation Copper cables 5kV?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor insulation, MV105 or MV90 Non Shielded EPR Hypalon Heavy Wall 133% Copper cable 2.4kV-5kV Cablesuse Ethylene propylene rubber (EPR) per ICEA standards. \u003c\/p\u003e\n\u003cp\u003eMV105 or MV90 Non Shielded XLP 133% Insulation Copper cables 5kV uses Cross-linked polyethylene (XLP) per ICEA regulations.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003eWhat are the regulations and uses of MV105 or MV90 Non Shielded EPR Hypalon Heavy Wall 133% Copper 2.4kV-5kV Cables and MV105 or MV90 Non Shielded XLP 133% Insulation Copper cables 5kVunder specific temperature conditions?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe National Electric Code has allowed the use of both thepowercables at 90°C for continuous operation, 130°C for emergency overload conditions and 250°C for short circuit conditions.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003eWhat is the difference between MV105 or MV90 Non Shielded EPR Hypalon Heavy Wall 133% Copper 2.4kV-5kV Cables and MV105 or MV90 Non Shielded XLP 133% Insulation Copper cables 5kV?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe main difference between bothcables lies in the fact that MV105 or MV90 Non Shielded EPR Hypalon Heavy Wall 133% Copper cable 2.4kV-5kV Cables have Jacket made of Chloro-sulfonated polyethylene (CSPE\/Hypalon®) as per ICEA standards. It also complies with flame tests - UL and IEEE 383 70,000 BTU\/hr flame test – for CT-listed sizes 1\/0 AWG and larger.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003eWhat are the national and international standards to which MV105 or MV90 Non Shielded EPR Hypalon Heavy Wall 133% Copper 2.4kV-5kV Cables and MV105 or MV90 Non Shielded XLP 133% Insulation Copper cables 5kVconform?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBoth Power Cables conform to all major national and international technical standards of the industry such as:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eICEA S-96-659\u003c\/li\u003e\n\u003cli\u003eUL Standard 1072\u003c\/li\u003e\n\u003cli\u003eNEMA WC71\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27521970307172,"sku":"NNC5103X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/Product25.png?v=1762459742"},{"product_id":"single-conductor-non-shielded-epr-133-hypalon-cspe-jacket-mv-105-cable-5kv","title":"Single Conductor Non-Shielded EPR 133% Hypalon CSPE Jacket MV-105 Cable 5KV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/o-2_2.pdf?v=1729673616\" width=\"\" height=\"\" type=\"application\/pdf\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSingle Conductor Non-Shielded EPR 133% Hypalon Jacket MV-105 Cable 5KV\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e• \u003c\/span\u003eA. Where NEC jurisdiction applies; as 5,000 volt nonshielded power cable. Type MV-105, for use at conductor temperatures not exceeding 105°C in wet or dry locations. Cables meet requirments of Article 310-6 of the National Electrical Code.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e• \u003c\/span\u003eB. For other applications, as nonshielded power cables for use at 5000 volts 100% insulation level (grounded neutral) and 133% insulation level (ungrounded neutral) under the following conditions: (a) Single conductors mounted on insulation in free air in indoor or outdoor locations.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e• \u003c\/span\u003eCircuit voltages are 2400 volts, 4160 volts and 4800 volts. (b) Random lay singles in metal conduit and nonmetallic conduit in dry locations at circuit voltage of 2400 volts, 4160 volts and 4800 volts, and in damp or wet locations at circuit voltages of 2400 volts and 4160 volts.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e• \u003c\/span\u003e(c) Triplexed singles in metal conduit and nonmetallic conduit in damp or wet locations at circuit voltage of 4800 volts.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e• \u003c\/span\u003e(d) Single conductors or triplexed singles in cable tray, spaced block supports or in messenger supported rings in dry, damp or wet locations at circuit voltages of 2400 volts and 4160 volts. \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e• \u003c\/span\u003e(e) Triplexed singles in cable tray, spaced block supports or in messenger supported rings in damp or wet locations at circuit voltage of 4800 volts.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e• \u003c\/span\u003e(f) Single conductors or triplexed singles, aerially, field-spun to grounded messenger in dry, damp or wet locations at circuit voltages of 2400 volts, 4160 volts, and 4800 volts.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHypalon Jacket Cable, MV Cable, Medium Voltage Cable, CSPE Cable, MV-105 Cable, MV 5K Cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e• \u003c\/span\u003eListed by Underwriters Laboratories as 5,000 volt nonshielded cable, Type MV-105 per UL Standard 1072\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eConforms to ICEA Pub. No. 539-693 and NEMA Pub. No. WC4 for Ethylene-propylene rubber-insulated Wire and Cable\u003cbr\u003e• Sizes 1\/0 and larger pass UL and IEEE Standard 383 ribbon burner flame test and are UL listed for CT use\u003cbr\u003e• Construction: Annealed tinned copper conductor, extruded conductor shield, EPR insulation, discharge and moisture resistant Hypalon jacket, surface printed\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27521971519588,"sku":"NNC5118X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/Product26.png?v=1759804899"},{"product_id":"mv-105-or-mv-90-xlp-insulation-pvc-jacket-133-5kv","title":"MV105 or MV90 XLP Insulation PVC Jacket Shielded 100% or 133% 5KV","description":"\u003cp\u003e[short]\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003eMV105 or MV90 XLP Insulation PVC Jacket Shielded 100% or 133% 5KV\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eApplications:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe mv105 copper cable is an electrical wire used for power circuits up to 5,000 Volts when fixed in open air, conduit, or duct; in applications such as chemical plants, refineries, steel mills, industrial plants, commercial buildings, utility substations, and generating stations. The National Electric Code accepts this electrical cable for uses within 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eAlso Known As:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eMedium voltage power cables, mv power cable, mv105 cable, mv105, pvc jacket.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eStandards:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eICEA S-93-639\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eNEMA WC74\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eAEIC CS8\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eFederal Specification J-C-30B\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eConstruction\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eConductors:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe MV power cable conductor is made of soft bare copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed), or ASTM B-496 (compact), with a semi-conducting conductor shield.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eInsulation:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe MV power cable has cross-linked polyethylene (XLP) insulation. The conductors are normally cabled together with XLP insulated aluminum ground or bare copper ground and covered with reinforced binder tape. XLP insulation is tough and resistant to impact, abrasion, chemicals, acids, oils, industrial solvents, and changes in weather.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eJacket:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eReinforced insulation is provided by a PVC jacket, which is \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003esunlight-resistant, per ICEA S-97-682 and UL Standard 1072.\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr style=\"font-size: 1.4em;\"\u003e\u003cspan style=\"font-size: 1.4em;\"\u003e [\/short] \u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 1.4em;\"\u003e\u003cstrong\u003eMV105 OR MV90 XLP SHIELDED 5kV\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 1.4em;\"\u003eAs hinted earlier in the article, this cable can be used in power circuits in relatively corrosive environments of applications up to 5000 volts. It can also be installed in conduits, ducts, cable trays and open air if CT rated in both wet and dry locations. Its main uses as hinted earlier are in chemical plants, industrial plants, refineries and commercial buildings. In addition this cable also works very well in a wide range of temperatures whereby its normal continuous operating temperature is at 90 degrees Celsius, however if can still functions to temperatures up to 130 degrees Celsius for emergency overload conditions and 250 degrees Celsius in case of a short circuit.\u003c\/p\u003e\n\u003cp style=\"font-size: 1.4em;\"\u003eWhen it comes to the cable’s construction, the conductor is made from copper. \u003ca href=\"https:\/\/www.nassauelectrical.com\/products\/copper-building-wire\"\u003eCopper building wire\u003c\/a\u003e is the most preferred metal for this purpose since it has amazing electrical properties hence it can be able to transmit large amounts of electricity and at a faster rate compared to other metals. On top of the conductor is a semi-conducting shield that protects the conductor from external forces that may cause damage to the cable.\u003c\/p\u003e\n\u003cp style=\"font-size: 1.4em;\"\u003eWhenever there is a conductor an insulator should be put in place to ensure safety to the user. The insulator used in this case as its name implies is a cross-linked polyethylene (XLP) material which is relatively robust. The insulator also has a semi-conducting shield that protects the insulator. In addition to its design is an overall jacket that protects the inner components of the cable from sunlight, abrasion and other external forces. For this purpose the jacket needs to be robust hence a PVC material is used.\u003c\/p\u003e\n\u003cp style=\"text-align: left;\" data-mce-style=\"text-align: left;\"\u003e\u003cstrong\u003eQuestion and Answer:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\" data-mce-style=\"text-align: center;\"\u003e\u003cstrong\u003eFrequently Asked Questions - MV105 OR MV90 XLP INSULATION PVC JACKET SHIELDED 100% OR 133% 5kV Power Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 1.4em;\"\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\" data-mce-style=\"text-decoration: underline;\"\u003eWhat are the specific applications of MV105 or MV90 XLP Insulation PVC Jacket Shielded Power Cables?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 1.4em;\"\u003eMV105 or MV90 XLP Insulation PVC Jacket Shielded 100% or 133% Power Cables are suitable for corrosive environments and in power circuits which are usually seen in open air, conduit \u0026amp; duct; and cable tray when CT rated in wet and dry conditions. These power cables are appropriate for chemical plants, refineries, steel mills, industrial plants, commercial buildings, utility substations and general stations.\u003c\/p\u003e\n\u003cp style=\"font-size: 1.4em;\"\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\" data-mce-style=\"text-decoration: underline;\"\u003eWhat is the insulation used for MV105 or MV90 XLP Insulation PVC Jacket Shielded 100% or 133% Power Cables?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 1.4em;\"\u003eThese power cables use a semi-conducting insulation shield of cross-linked polyethylene (XLP) that qualifies the ICEA S-97-682 standards.\u003c\/p\u003e\n\u003cp style=\"font-size: 1.4em;\"\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\" data-mce-style=\"text-decoration: underline;\"\u003eWhat are the regulations and uses of MV105 or MV90 XLP Insulation PVC Jacket Shielded 100% or 133% Power Cables under specific temperature conditions?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 1.4em;\"\u003eNational Electric Code has allowed the use of MV105 or MV90 XLP Insulation PVC Jacket Shielded 100% or 133% Power Cables at 90°C for continuous operation, 130°C for emergency overload conditions and 250°C for short circuit conditions.\u003c\/p\u003e\n\u003cp style=\"font-size: 1.4em;\"\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\" data-mce-style=\"text-decoration: underline;\"\u003eWhat type of Jacket does the MV105 or MV90 XLP Insulation PVC Jacket Shielded 100% or 133% Power Cables have?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 1.4em;\"\u003eMV105 or MV90 XLP Insulation PVC Jacket Shielded 100% or 133% Power Cables are having sunlight resistant PVC as per the standards ofICEA S-97-682 and UL Standard 1072.\u003c\/p\u003e\n\u003cp style=\"font-size: 1.4em;\"\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\" data-mce-style=\"text-decoration: underline;\"\u003eIs it possible to customize the MV105 or MV90 XLP Insulation PVC Jacket Shielded 100% or 133% Power Cables?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 1.4em;\"\u003eYes. You can request for the specific requirements with the seller. Even though it depends on the gauge and the type of wire used, it is almost possible for us to provide the exact cable as per your requirements. It also depends on what the factory is running at that time of your request.\u003c\/p\u003e\n\u003cp style=\"font-size: 1.4em;\"\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\" data-mce-style=\"text-decoration: underline;\"\u003eWhat sizes of power cables are available in MV105 or MV90 XLP Insulation PVC Jacket Shielded 100% or 133% range?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 1.4em;\"\u003eMV105 or MV90 XLP Insulation PVC Jacket Shielded 100% or 133% Power Cables are available through 8 AWG – 1000 MCM.The followingis their Gauge sizes and stranding:\u003c\/p\u003e\n\u003cp style=\"font-size: 1.4em;\"\u003e\u003cspan style=\"text-decoration: underline;\" data-mce-style=\"text-decoration: underline;\"\u003eI.E Gauges + Stranding\u003c\/span\u003e:\u003c\/p\u003e\n\u003cp style=\"font-size: 1.4em;\"\u003e8\/7 = Gauge size 8, Stranding 7\u003c\/p\u003e\n\u003cp style=\"font-size: 1.4em;\"\u003e1\/0-19 = Gauge size 1\/0, Stranding 19\u003c\/p\u003e\n\u003cp style=\"font-size: 1.4em;\"\u003e350\/37 = Gauge size 350, Stranding 37\u003c\/p\u003e\n\u003cp style=\"font-size: 1.4em;\"\u003e1000\/61 = Gauge size 1000, Stranding 61\u003c\/p\u003e\n\u003cp style=\"font-size: 1.4em;\"\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\" data-mce-style=\"text-decoration: underline;\"\u003eWhat are the national and international standards to which MV105 or MV90 XLP Insulation PVC Jacket Shielded 100% or 133% Power Cables conform?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 1.4em;\"\u003eMV105 or MV90 XLP Insulation PVC Jacket Shielded 100% or 133% Power Cablesconforms to all major national and international technical standards of the industry such as:\u003c\/p\u003e\n\u003cul style=\"font-size: 1.4em;\"\u003e\n\u003cli\u003e\u003cstrong\u003eICEA S-97-682\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eUL Standard 1072\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eICEA S-93-639\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eNEMA WC74\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAEIC CS8\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eFederal Specification J-C-30B\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27521973387364,"sku":"NNC5132X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/Product29.png?v=1759804902"},{"product_id":"mv105-epr-insulation-pvc-jacket-shielded-100-133-copper-5kv-8kv","title":"MV105 EPR PVC JACKET SHIELDED 100% OR 133% COPPER POWER CABLE 5kV \/ 8kV","description":"\u003cp\u003e[short]\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003eMV105 EPR PVC JACKET SHIELDED 100% OR 133% COPPER POWER CABLE 5kV \/ 8kV\u003c\/h2\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003eApplications:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003eThe mv105 copper cable is an electrical wire used for power circuits up to 5,000 Volts when fixed in open air, conduit, or duct; in applications such as chemical plants, refineries, steel mills, industrial plants, commercial buildings, utility substations, and generating stations. The National Electric Code accepts this electrical cable for uses within 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003eAlso Known As:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003eMedium voltage power cables, mv power cable, mv105 cable, mv105, pvc jacket.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003eStandards:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003eICEA S-93-639\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003eNEMA WC74\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003eAEIC CS8\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003eFederal Specification J-C-30B \u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003eConstruction\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003eConductors:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003eThe MV power cable conductor is made of soft bare copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed), or ASTM B-496 (compact), with a semi-conducting conductor shield.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003eInsulation:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003eThe MV power cable has cross-linked polyethylene (XLP) insulation. The conductors are normally cabled together with XLP insulated aluminum ground or bare copper ground and covered with reinforced binder tape. XLP insulation is tough and resistant to impact, abrasion, chemicals, acids, oils, industrial solvents, and changes in weather.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003eShield:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003eShielding wires meet ICEA standards.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003eJacket:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003eReinforced insulation is provided by a PVC jacket, which is \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003esunlight-resistant, per ICEA S-97-682 and UL Standard 1072.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e [\/short]\u003c\/p\u003e\n\u003cp style=\"font-size: 1.4em;\"\u003e\u003cstrong\u003eMV105 COPPER POWER CABLE 5kV \/ 8kV\u003c\/strong\u003e\u003c\/p\u003e\nThese are among the variety of \u003ca href=\"https:\/\/www.nassaunationalcable.com\/wire-and-cable\/medium-voltage\/5k-8k.html\"\u003epower cables\u003c\/a\u003e readily found at Nassau national cable. This power cable is meant for applications rated at 5000 volts and 8000 volts in relatively corrosive environments. It’s designed for heavy weight applications compared to the previous cable. The MV105 cable can work properly in a wide range of temperatures, whereby its operating temperature is at 90 degrees Celsius. In case of emergency overload conditions it can withstand temperatures up to 130 degrees Celsius and 250 degrees Celsius if a short circuit occurs. \u003cbr\u003eIt has copper conductors as the electrolyte. The copper conductor is also stranded to enhance flexibility and can be able to carry large amounts of electric current. The copper conductor also has a semi-conducting shield that protects the conductor from damage. It has a robust material as the insulator which is made from of cross-linked polyethylene (XLP). For 5000 voltage rating the insulation coverage is at 100% but for 8000 volts the insulation coverage is 133% considering the higher voltage. The insulator also has a semi-conducting shield covering it. An overall shielding wire is added to prevent mechanical and electromagnetic forces from affecting the cable. An overall PVC jacket is installed to protect the inner components of the cable. With this type of cable design, it makes it durable and less prone to damages.","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27521974632548,"sku":"NNC5147X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/Product30.png?v=1762459772"},{"product_id":"mv-105-epr-insulation-cpe-jacket-shielded-unshielded-100-133-copper","title":"MV105 EPR Insulation CPE Jacket 100% or 133% Copper Power Cable 5KV \/ 8KV","description":"\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch2\u003eMV105 EPR Insulation CPE Jacket 100% or 133% Copper Power Cable 5KV \/ 8KV\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eApplications:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe mv105 copper cable is an electrical wire used for power circuits up to 5,000 Volts when fixed in open air, conduit, or duct; in applications such as chemical plants, refineries, steel mills, industrial plants, commercial buildings, utility substations, and generating stations. The National Electric Code accepts this electrical cable for uses within 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eAlso Known As:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eMedium voltage power cables, epr power cable, mv power cable, mv105 cable, mv105. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eStandards:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eICEA S-93-639\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eNEMA WC74\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eAEIC CS8\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eFederal Specification J-C-30B\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eConstruction\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eConductors:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe MV power cable conductor is made of copper: \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003ewith soft bare annealed copper per ASTM B-3, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eClass B stranding per ASTM B-8 (compressed), or ASTM B-496 (compact), with a semi-conducting conductor shield.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eInsulation:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eA strong and enduring ethylene-propylene rubber (EPR) is used as the insulation system. The good thing about this insulation is how friendly it is to human hands since it is a rubber, a material that tends to be soft but guarantees profound and reliable safety wires. This insulation is also environmentally friendly, it doesn’t have some toxics which can cause harm to human, animals, and plants health.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eJacket:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe jacket of this ERP power cable is made of Thermoset Chlorinated Polyethylene (TS CPE).\u003c\/span\u003e\u003cbr\u003e [\/short]\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMV105 POWER CABLE 5kV \/ 8kV\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe MV105 copper power cable is also recommended for applications rated at 5000 volts and 8000 volts hence it can be used in heavy duty applications in relatively corrosive areas. The normally operating temperature of this cable is 90 degrees Celsius but in case of emergency overload conditions it can withstand temperatures of up to 130 degrees Celsius and 250 degrees in case a short circuit occurs. This is essentially because it is designed for corrosive environments which may cause constant change in temperature.\u003c\/p\u003e\n\u003cp\u003eA conductor which acts as the cable’s electrolyte is made of copper which is stranded to increase efficiency and reliability of the cable. Laced on top of the conductor is a semi-conducting shield. The insulation is made of cross-linked polyethylene (XLP) and on top of it is another semi-conducting insulation shield. When it comes to the overall cable shield there are both shielded and unshielded options for you to choose from. The overall cable jacket is made from polyvinyl chloride (PVC) which is advantageous due to its effective resistance to sunlight and abrasion.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion and Answer:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFrequently Asked Questions - MV105 EPR INSULATION CPE JACKET SHIELDED OR UNSHIELDED 100% OR 133% INSULATION COPPER POWER CABLE 5kV \/ 8kV\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWhat are the specific applications of MV105 EPR Insulation CPE Jacket Shielded or Unshielded 100% or 133% Power Cables?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMV105 EPR Insulation CPE Jacket Shielded or Unshielded 100% or 133% Power Cables are suitable for corrosive environments in power circuits up to 5000V which are installed in open air, conduit \u0026amp; duct; cable tray when CT rated, in wet and dry conditions. These power cables are appropriate for chemical plants, refineries, steel mills, industrial plants, commercial buildings, utility substations and general stations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWhat type of conductor is used for MV105 EPR Insulation CPE Jacket Shielded or Unshielded 100% or 133% Power Cables?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe power cables have a semi-conducting conductor shield of soft bare annealed copper which qualify the ASTM B-3. It also has Class B stranding as per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the insulation used for MV105 EPR Insulation CPE Jacket Shielded or Unshielded 100% or 133% Power Cables?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThese power cables use a semi-conducting insulation shield of cross-linked polyethylene (XLP) that qualifies the ICEA S-97-682 standards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWhat are the regulations and uses of MV105 EPR Insulation CPE Jacket Shielded or Unshielded 100% or 133%Power Cables under specific temperature conditions?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe National Electric Code has allowed the use of MV105 EPR Insulation CPE Jacket Shielded or Unshielded 100% or 133% PowerCables at 90°C for continuous operation, 130°C for emergency overload conditions and 250°C for short circuit conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWhat type of Jacket does the MV105 EPR Insulation CPE Jacket Shielded or Unshielded 100% or 133% Power Cables have?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor Jacket, MV105 EPR Insulation CPE Jacket Shielded or Unshielded 100% or 133% Power Cables are having sunlight resistant PVC as per the standards of ICEA S-97-682 and UL Standard 1072.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWhat sizes of power cables are available in MV105 EPR Insulation CPE Jacket Shielded or Unshielded 100% or 133% cablerange?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMV105 EPR Insulation CPE Jacket Shielded or Unshielded 100% or 133% Power Cables are available through 8 AWG – 1000 MCM. The followingis their Gauge sizes and stranding:\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eI.E Gauges + Stranding\u003c\/span\u003e:\u003c\/p\u003e\n\u003cp\u003e8\/7 = Gauge size 8, Stranding 7\u003c\/p\u003e\n\u003cp\u003e1\/0-19 = Gauge size 1\/0, Stranding 19\u003c\/p\u003e\n\u003cp\u003e350\/37 = Gauge size 350, Stranding 37\u003c\/p\u003e\n\u003cp\u003e1000\/61 = Gauge size 1000, Stranding 61\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWhat are the national and international standards to which MV105 EPR Insulation CPE Jacket Shielded or Unshielded 100% or 133% Power Cables conform?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMV105 EPR Insulation CPE Jacket Shielded or Unshielded 100% or 133%Power Cables conforms to all major national and international technical standards of the industry such as:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eICEA S-97-682\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eUL Standard 1072\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eICEA S-93-639\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eNEMA WC74\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAEIC CS8\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eFederal Specification J-C-30B\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27521976959076,"sku":"NNC5161X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/Product31.png?v=1762459780"},{"product_id":"type-ul-mv-90-epr-insulation-cpe-jacket-shielded-100-copper","title":"Type UL MV90 CPE Jacket Shielded 100% Copper Power Cable 15KV","description":"\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch2\u003eType UL MV90 CPE Jacket Shielded 100% Copper Power Cable 15KV\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eApplications:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe mv90 copper cable is an electrical wire used for power circuits up to 15,000 Volts when fixed in open air, conduit, or duct; in applications such as chemical plants, refineries, steel mills, industrial plants, commercial buildings, utility substations, and generating stations. The National Electric Code accepts this electrical cable for uses within 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eAlso Known As:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eMedium voltage power cables, mv power cable, mv90 cable, mv90, mv 90 air compressor, epr power cable. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eStandards:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eICEA S-93-639\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eNEMA WC74\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eAEIC CS8\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eConstruction\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eConductors:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe MV power cable conductor is made of copper with a semi-conducting conductor shield: soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed), or ASTM B-496 (compact).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eInsulation:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eA strong and enduring ethylene-propylene rubber (EPR) is used as the insulation system. The good thing about this insulation is how friendly it is to human hands since it is a rubber, a material that tends to be soft but guarantees profound and reliable safety wires. This insulation is also environmentally friendly, it doesn’t have some toxins which can cause harm to human, animals, and plants health.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eJacket:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eReinforced insulation is provided by a PVC jacket, which is \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003esunlight-resistant, per ICEA S-97-682 and UL Standard 1072.\u003c\/span\u003e \u003cbr\u003e [\/short]\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eType UL MV 90  Copper Power Cable 15kV\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eLooking for a strong and versatile cable for your circuit whose voltage consumption is up to 15KV? You desire a cable to use in an application where the environment is highly corrosive? Then you should consider \u003ca href=\"https:\/\/www.nassaunationalcable.com\/wire-and-cable\/medium-voltage\/15k\/type-ul-mv-90-epr-insulation-cpe-jacket-shielded-100-copper.html\"\u003eType UL MV 90 EPR cable\u003c\/a\u003e. The cable is technically designed with outstanding features that fits it for the applications. Even its packaging is of standards prescribed therefore the products is always in a suitable condition.\u003c\/p\u003e\n\u003cp\u003eAmount of work that this cable needs to do is huge, working in harsh conditions which require that the cable should have extra toughness and mechanically strong insulation. Besides the intensity of the area of application, you also need to consider the voltage size of the load. 15000 Voltage rated circuit would require a cable which is thorough in both mechanical and electrical functionalities. Here are the fundamental features which will make you chose this cable above other cables of the same stature.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cb\u003eConductors\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eType MV-90 15KV \u003ca href=\"https:\/\/www.nassaunationalcable.com\/wire-and-cable\/medium-voltage.html\"\u003eMedium voltage power cable\u003c\/a\u003e is made of copper conductor. The type of conductor for every cable matters. If you ignore the issue of conductor type, then you will be falling in the trap for fake cables. Copper conductors have  high conductivity and more readily available. Copper has some weaknesses like, it easily gets corroded and consumed by reactive agents. But these disadvantages have been curbed by the meticulous design which has greatly improved the copper conductor hence it no longer gets corroded easily. It is due to this sturdy design process that makes it fit for applications in the corrosive environments.\u003c\/p\u003e\n\u003cp\u003eType MV-90 cable has a conductor shield which is semi conducting. The copper conductor used for this cable is bare, soft and annealed. Two types of conductor are involved: compacted and stranded conductor which are designed according to ASTM B-3 and ASTM B-8 consecutively. Your choice for the type of the conductor cable will be influenced by the type of application where you will desire to use it for, of which your will be guided upon placing your orders.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cb\u003eInsulation\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis cable has a very enduring and resilient insulation system. It is this elaborate insulation which provides enough security to the cable conductors without which the conductors are vulnerable to high mechanical damages and infiltration of corroding chemicals. Type MV-90 cable is a power cable that distributes heavy voltage power and a sturdy insulation plays a key role in its operations. That is why this product has ethylene propylene rubber (EPR) according to the standards of ICEA S-97-682. This material is extra tough and mechanically resilient.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cb\u003eShield\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe shield reinforces the security and the functionalities of this conductor. The shielding wire is very crucial because it greatly enhances its safety. The cable’s shield wire is designed according to ICEA standards.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cb\u003eJacket\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAn overall wrapped insulation structure in the name of “jacket” is also a key feature in the makeup of this cable. This jacket provides an entire security to the cable. Type MV-90 power cable has sunlight resistance PVC jacket, which is designed according to the ICEA S-97-682 and UL standard 1072.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cb\u003eApplications\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis type of medium voltage power cable is robust, versatile and reliable since it is appropriate for various functions. The cable has high proficiency and adaptability, making it suitable to be used in a wide scope of applications. Corrosive environment can be a prominent enemy to the life of a cable but type MV-90 cable is well suitable for the environment.\u003c\/p\u003e\n\u003cp\u003eThis power cable is also appropriate for open air, conduct, duct and cable tray installation in both wet and dry places. The cable has been tested and proven to be fit for systems and control units of refineries, steel mills, chemical and industrial plants. It is also useful for commercial buildings, utility substations and generation stations.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eOperation\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eType MV-90 15KV Medium Voltage Power Cable operates at 90 degrees Celsius continuous as permitted by National Electric Code. During emergency, the cable can operate up to 130 degrees Celsius for overload conditions. Moreover, it can operate at 250\u003csup\u003e0\u003c\/sup\u003eC during short circuit condition. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestions and Answer:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFrequently Asked Questions - TYPE UL MV105 EPR INSULATION CPE JACKET SHIELDED 100% INSULATION COPPER POWER CABLE 15kVand TYPE UL MV105 SHIELDED EPR INSULATION PVC JACKET 133% INSULATION COPPER POWER CABLE 15kV\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWhat are the specific applications of Type UL MV105 EPR Insulation CPE Jacket Shielded 100% Insulation Copper Power Cable 15kV and Type UL MV105 Shielded EPR Insulation PVC Jacket 133%Insulation Copper Power Cable 15kV?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThese power cablesare suitable for corrosive environments in power circuits up to 15,000V which are installed in open air, conduit \u0026amp; duct; cable tray when CT rated, in wet and dry conditions. These power cables are appropriate for chemical plants, refineries, steel mills, industrial plants, commercial buildings, utility substations and general stations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the type of conductor used for Type UL MV105 EPR Insulation CPE Jacket Shielded 100% Insulation Copper Power Cable 15kV and Type UL MV105 Shielded EPR Insulation PVC Jacket 133%Insulation Copper Power Cable 15kV?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe power cables have a semi-conducting conductor shield, with a compacted soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the insulation used for Type UL MV105 EPR Insulation CPE Jacket Shielded 100% Insulation Copper Power Cable 15kV and Type UL MV105 Shielded EPR Insulation PVC Jacket 133%Insulation Copper Power Cable 15kV?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBoth the power cables Type UL MV105 EPR Insulation CPE Jacket Shielded 100% Insulation Copper Power Cable 15kV and Type UL MV105 Shielded EPR Insulation PVC Jacket 133% Insulation Copper Power Cable 15kV have Ethylene propylene rubber (EPR) per ICEA S-97-682 with a semi-conducting insulation shield.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWhat are the regulations and uses of Type UL MV105 EPR Insulation CPE Jacket Shielded 100% Insulation Copper Power Cable 15kV and Type UL MV105 Shielded EPR Insulation PVC Jacket 133%Insulation Copper Power Cable 15kVunder specific temperature conditions?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe National Electric Code has allowed the use of Type UL MV105 EPR Insulation CPE Jacket Shielded 100% Insulation Copper Power Cable 15kV at 90°C for continuous operation, 130°C for emergency overload conditions and 250°C for short circuit conditions.\u003c\/p\u003e\n\u003cp\u003eFor Type UL MV105 Shielded EPR Insulation PVC Jacket 133% Insulation Copper Power Cable 15kV, its 105°C for continuous operation, 140°C for emergency overload conditions, and 250°C for short circuit conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWhat are the national and international standards to which Type UL MV105 EPR Insulation CPE Jacket Shielded 100% Insulation Copper Power Cable 15kV and Type UL MV 105 Shielded EPR Insulation PVC Jacket 133%Insulation Copper Power Cable 15kVconform?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBoth the Power Cables conforms to all major national and international technical standards of the industry such as:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eICEA S-93-639\u003c\/li\u003e\n\u003cli\u003eICEA S-97-682\u003c\/li\u003e\n\u003cli\u003eNEMA WC74\u003c\/li\u003e\n\u003cli\u003eAEIC CS8\u003c\/li\u003e\n\u003cli\u003eFederal Specification J-C-30B\u003c\/li\u003e\n\u003cli\u003eUL Standard 1072\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27521983905892,"sku":"NNC5171X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/Product33.png?v=1762459787"},{"product_id":"ype-ul-mv90-single-conductor-shielded-xlp-insulation-pvc-jacket-133-copper","title":"Type UL MV90 Single Conductor PVC Jacket 133% Copper Power Cable 15kV","description":"\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch2\u003eType UL MV90 Single Conductor PVC Jacket 133% Copper Power Cable 15kV\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eApplications:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe mv90 copper cable is an electrical wire used for power circuits up to 15,000 Volts when fixed in open air, conduit, or duct; in applications such as chemical plants, refineries, steel mills, industrial plants, commercial buildings, utility substations, and generating stations. The National Electric Code accepts this electrical cable for uses within 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eAlso Known As:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eMedium voltage power cables, mv power cable, mv90 cable, mv90, mv 90 air compressor, pvc jacket. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eStandards:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eICEA S-93-639\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eNEMA WC74\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eAEIC CS8\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eConstruction\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eConductors:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe MV power cable conductor is made of copper with a semi-conducting conductor shield: soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed), or ASTM B-496 (compact).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eInsulation:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eA strong and enduring ethylene-propylene rubber (EPR) is used as the insulation system. The good thing about this insulation is how friendly it is to human hands since it is a rubber, a material that tends to be soft but guarantees profound and reliable safety wires. This insulation is also environmentally friendly, it doesn’t have some toxins which can cause harm to human, animals, and plants health.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eJacket:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eReinforced insulation is provided by a PVC jacket, which is \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003esunlight-resistant, per ICEA S-97-682 and UL Standard 1072.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e [\/short]\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.nassaunationalcable.com\/wire-and-cable\/medium-voltage\/15k\/ype-ul-mv90-single-conductor-shielded-xlp-insulation-pvc-jacket-133-copper.html\"\u003e\u003cb\u003eType UL MV90 Single Conductor Copper Power Cable 15KV\u003c\/b\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eThis is another power cable which is suitable for distribution of 15000 voltage power to various utility units. The cable has a sturdy and reliable insulation system thus good for any harsh and extreme demanding applications. Here are some of its features\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e \u003cb\u003eConductor\u003c\/b\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eA single conductor cable, which means it is not to be used for three or more phase power distribution. The conductor used is a soft bare and annealed copper with a semi conducting shield. The conductors are designed as either stranded or compressed according to the ASTM B-496.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cb\u003eInsulation\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eXLP insulation provides a versatile protection to the cable conductors. The insulation for \u003ca href=\"https:\/\/www.nassaunationalcable.com\/wire-and-cable\/medium-voltage\/15k\/ype-ul-mv90-single-conductor-shielded-xlp-insulation-pvc-jacket-133-copper.html\"\u003eType UL MV90 Single Conductor Cable\u003c\/a\u003e is made of ethylene propylene rubber (EPR). Insulation material is strong and human friendly; its design is top notch as per ICEA S-97-682\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cb\u003eJacket\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe sunlight PVC jacket offers a reliable protection for this cable. It is only at \u003ca href=\"https:\/\/www.nassaunationalcable.com\/contacts\/\"\u003eNassau National Cable\u003c\/a\u003e where you can get cables which are thoroughly manufactured with top most protective features according to UL Standard 1072.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cb\u003eShield\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eA shielding wire which this cable is made with improves its efficiency.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cb\u003eApplication\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe cable is mainly for use in the industrial plants such as chemical plants, steel mills and refineries. Due to its extra tough and mechanical strength, the cable fits for wiring in the commercial buildings. As we mentioned earlier, the cable is fit for 15Kv utility systems that is why it is applied in the generation stations and utility substations.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cb\u003eOperation\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNational Electric Code approves the continuous operation of this cable at 90\u003csup\u003e0\u003c\/sup\u003eC. In cases of emergency like overload conditions, the cable can operate at 130\u003csup\u003e0\u003c\/sup\u003eC and 250\u003csup\u003e0\u003c\/sup\u003eC during short circuits. This shows how flexible and tolerant the product is for uncertainties that can befall your system operations.\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27521985052772,"sku":"NNC5184X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/Product34.png?v=1762459795"},{"product_id":"mv105-epr-insulation-pvc-jacket-shielded-100-copper-power-cable-15kv","title":"MV105 EPR Insulation PVC Jacket Shielded 100% Copper Power Cable 15KV","description":"\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch2\u003eMV105 EPR Insulation PVC Jacket Shielded 100% Copper Power Cable 15KV\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eApplications:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe mv105 copper cable is an electrical wire used for power circuits up to 15,000 Volts when fixed in open air, conduit, or duct; in applications such as chemical plants, refineries, steel mills, industrial plants, commercial buildings, utility substations, and generating stations. The National Electric Code accepts this electrical cable for uses within 105°C for continuous operation, 140°C for emergency overload conditions, and 250°C for short circuit conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eAlso Known As:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eMedium voltage power cables, mv power cable, erp power cable, mv105 cable, mv105, pvc jacket.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eStandards:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eICEA S-93-639\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eNEMA WC74\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eAEIC CS8\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eFederal Specification J-C-30B\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eConstruction\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eConductors:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe MV power cable conductor is made of copper and has a conductor shield \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003ewith soft bare annealed copper per ASTM B-3,\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e Class B stranding per ASTM B-8 (compressed), or ASTM B-496 (compact).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eInsulation:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eA strong and enduring ethylene-propylene rubber (EPR) is used as the insulation system. The good thing about this insulation is how friendly it is to human hands since it is a rubber, a material that tends to be soft but guarantees profound and reliable safety wires. This insulation is also environmentally friendly, it doesn’t contain any toxins which can cause harm to human, animals, and plants health.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eShield:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eUncoated copper tape with a minimum 12.5% overlap per ICEA S-97-682.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eJacket:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eReinforced insulation is provided by a PVC jacket, which is \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003esunlight-resistant, per ICEA S-97-682 and UL Standard 1072.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e [\/short]\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eMV105 Copper Power Cable 15KV\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA single conductor power cable whose voltage power rating is 15KV hence appropriate for all power circuits operation on 15KV Power voltage. Have a look at its features\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cb\u003eConductor\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eLike other \u003ca href=\"https:\/\/www.nassaunationalcable.com\/wire-and-cable\/medium-voltage\/15k\/type-ul-mv105-shielded-epr-insulation-cpe-jacket-133.html\"\u003e15KV Medium Voltage Power Cable\u003c\/a\u003e, this cable is also made from copper conductors. The conductor has a semiconductor shield which reinforces its efficiency. Copper is soft and annealed, a characteristic which make it easier to mend and work with.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cb\u003eInsulation\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eEthylene propylene rubber provides the sturdy protection as an insulator to the cable conductors. It is with this insulation that the semi conducting shield helps in reinforcing the cable security against any damage. An enduring PVC sunlight resistant jacket helps to protect the whole cable. This jacket provides an entire wrap of conductor and is always in contact with the external world that is why is extra tough and mechanically strong.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eApplications\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.nassaunationalcable.com\/wire-and-cable\/medium-voltage\/15k\/type-ul-mv-90-epr-insulation-cpe-jacket-shielded-100-copper.html\"\u003eMV105 EPR Insulation Cable\u003c\/a\u003e serves you well in corrosive environments, it prevents tightly any infiltration of corrosive agents into the cable. It is rated 15KV therefore it will work well for your 15KV power circuits which are either installed in open air, duct and conduit, in cable trays. Various industrial and chemical plants use this cable, so you can use it without doubt in refineries, steel mills, commercial building, sub stations and generation stations.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eOperation\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThis type of cable works efficiently in both wet and dry locations with a temperature of up to 105\u003csup\u003e0\u003c\/sup\u003eC continuously as permitted by NEC. National Electric Code also approves that it can operate on 140\u003csup\u003e0\u003c\/sup\u003eC during emergency overloads and 250 degrees Celsius during any short circuit happenings.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.nassaunationalcable.com\/wire-and-cable\/medium-voltage\/15k.html\"\u003e15KV Medium Voltage Power Cable\u003c\/a\u003e is one line of products among many. And as you have seen, these cables have a wider scope of application which proves the quality with which they have been designed. A cable that can withstand all the extreme environment conditions. Its operational efficiency is then beyond doubt. Corrosive agents can bedevil your electric circuits especially in the coast and wet regions that is why the 15KV Medium Voltage Power cables have invincible insulation whose jacket it extra tough to offer reinforcement. \u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27521988067428,"sku":"NNC5186X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/Product35.png?v=1762459796"},{"product_id":"type-ul-mv105-shielded-epr-insulation-pvc-jacket-133-copper","title":"TYPE UL MV105 SHIELDED EPR INSUL PVC JACKET 133% COPPER POWER CABLE 15kV","description":"[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/TYPE_MV-105_133__JACKETED_EPR_POWER_CABLE_15KV.pdf?v=1624864990\" width=\"\" height=\"\" type=\"application\/pdf\"\u003e [\/pdf]\n\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch2\u003eTYPE UL MV105 SHIELDED EPR INSUL PVC JACKET 133% COPPER POWER CABLE 15kV\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eApplications:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe mv105 copper cable is an electrical wire used for power circuits up to 15,000 Volts when fixed in open air, conduit, or duct; in applications such as chemical plants, refineries, steel mills, industrial plants, commercial buildings, utility substations, and generating stations. The National Electric Code accepts this electrical cable for uses within 105°C for continuous operation, 140°C for emergency overload conditions, and 250°C for short circuit conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eAlso Known As:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eMedium voltage power cables, mv power cable, mv105 cable, mv105, pvc jacket, erp power cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eStandards:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eICEA S-93-639\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eNEMA WC74\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eAEIC CS8\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eFederal Specification J-C-30B\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eConstruction\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eConductors:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe MV power cable conductor is made of copper and has a conductor shield \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003ewith soft bare annealed copper per ASTM B-3,\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e Class B stranding per ASTM B-8 (compressed), or ASTM B-496 (compact).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eInsulation:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eA strong and enduring ethylene-propylene rubber (EPR) is used as the insulation system. The good thing about this insulation is how friendly it is to human hands since it is a rubber, a material that tends to be soft but guarantees profound and reliable safety wires. This insulation is also environmentally friendly, it doesn’t contain any toxins which can cause harm to human, animals, and plants health.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eShield:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eUncoated copper tape with a minimum 12.5% overlap per ICEA S-97-682.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eJacket:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eReinforced insulation is provided by a PVC jacket, which is \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003esunlight-resistant, per ICEA S-97-682 and UL Standard 1072.\u003c\/span\u003e\u003cbr\u003e [\/short]\u003c\/p\u003e\n\u003caddress\u003ePower Cable\u003c\/address\u003e\n\u003caddress\u003e\u003cspan\u003e15KV UL Type MV-105, 150°C\u003c\/span\u003e\u003c\/address\u003e\n\u003caddress\u003e\u003cspan\u003eSingle Conductor, Shielded\u003c\/span\u003e\u003c\/address\u003e\n\u003caddress\u003e\u003cspan\u003eEPR Insulation, PVC Jacket\u003c\/span\u003e\u003c\/address\u003e\n\u003caddress\u003e\n\u003cspan\u003e133% Insulation Level, \u003c\/span\u003e\u003cspan\u003eCopper Conductor\u003c\/span\u003e\n\u003c\/address\u003e\n\u003caddress\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/address\u003e\n\u003cp\u003e\u003cspan\u003eAppropriate for all situations of corrosive environments in power circuits up to 15,000V in all installations of open air, conduit, and duct, cable tray when CT rated, in wet and dry locations. Main uses are for chemical plants, refineries, steel mills, industrial plants, commercial buildings, utility substations and generating stations. National Electric Code permitted for use at 105°C for continuous operation, 140°C for emergency overload conditions, and 250°C for short circuit conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eHas a semi-conducting conductor shield, with soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEthylene propylene rubber (EPR) per ICEA S-97-682 with a semi-conducting insulation shield.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eUncoated copper tape with a minimum 12.5% overlap per ICEA S-97-682.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSunlight-resistant PVC per ICEA S-97-682 and UL Standard 1072.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003caddress\u003eICEA S-93-639\u003c\/address\u003e\u003c\/li\u003e\n\u003cli\u003e\u003caddress\u003eNEMA WC74\u003c\/address\u003e\u003c\/li\u003e\n\u003cli\u003e\u003caddress\u003eAEIC CS8\u003c\/address\u003e\u003c\/li\u003e\n\u003cli\u003e\u003caddress\u003eFederal Specification J-C-30B \u003c\/address\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27521989181540,"sku":"NNC5197X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Product28_8f21f142-6262-4f13-8e54-b92336c9b332.png?v=1762459805"},{"product_id":"type-ul-mv105-shielded-epr-insulation-cpe-jacket-100-copper-power-cable-15kv","title":"Type UL MV105 Shielded EPR Insulation CPE Jacket 100% Copper Power Cable 15KV","description":"\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch2\u003eType UL MV105 Shielded EPR Insulation CPE Jacket 100% Copper Power Cable 15KV\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eApplications:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe mv105 copper cable is an electrical wire used for power circuits up to 15,000 Volts when fixed in open air, conduit, or duct; in applications such as chemical plants, refineries, steel mills, industrial plants, commercial buildings, utility substations, and generating stations. The National Electric Code accepts this electrical cable for uses within 105°C for continuous operation, 140°C for emergency overload conditions, and 250°C for short circuit conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eAlso Known As:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eMedium voltage power cables, mv power cable, mv105 cable, mv105, erp power cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eStandards:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eNational Electric Code (NEC)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eUL 1072\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eUL listed as Type MV-105 for use in accordance with NEC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eUL 1685\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eOSHA Acceptable\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eConstruction\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eConductors:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe MV power cable conductor is made of copper and has a conductor shield \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003ewith soft bare annealed copper per ASTM B-3,\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e Class B stranding per ASTM B-8 (compressed), or ASTM B-496 (compact).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eInsulation:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eA strong and enduring ethylene-propylene rubber (EPR) is used as the insulation system. The good thing about this insulation is how friendly it is to human hands since it is a rubber, a material that tends to be soft but guarantees profound and reliable safety wires. This insulation is also environmentally friendly, it doesn’t contain any toxins which can cause harm to human, animals, and plants health.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eShield:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eShielded wires of six rigid copper longitudinally embedded in an exterior semi-conducting CPE jacket per ICEA S-97-682.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eJacket:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe jacket of this ERP power cable is made of Thermoset Chlorinated Polyethylene (TS CPE).\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n[\/short]\n\u003cp\u003e\u003cstrong\u003eFrequently Asked Questions - TYPE UL MV105 EPR INSULATION CPE JACKET SHIELDED 100% INSULATION COPPER POWER CABLE 15kVand TYPE UL MV105 SHIELDED EPR INSULATION PVC JACKET 133% INSULATION COPPER POWER CABLE 15kV\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWhat are the specific applications of Type UL MV105 EPR Insulation CPE Jacket Shielded 100% Insulation Copper Power Cable 15kV and Type UL MV105 Shielded EPR Insulation PVC Jacket 133%Insulation Copper Power Cable 15kV?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThese power cablesare suitable for corrosive environments in power circuits up to 15,000V which are installed in open air, conduit \u0026amp; duct; cable tray when CT rated, in wet and dry conditions. These power cables are appropriate for chemical plants, refineries, steel mills, industrial plants, commercial buildings, utility substations and general stations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the type of conductor used for Type UL MV105 EPR Insulation CPE Jacket Shielded 100% Insulation Copper Power Cable 15kV and Type UL MV105 Shielded EPR Insulation PVC Jacket 133%Insulation Copper Power Cable 15kV?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe power cables have a semi-conducting conductor shield, with a compacted soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the insulation used for Type UL MV105 EPR Insulation CPE Jacket Shielded 100% Insulation Copper Power Cable 15kV and Type UL MV105 Shielded EPR Insulation PVC Jacket 133%Insulation Copper Power Cable 15kV?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBoth the power cablesType UL MV105 EPR Insulation CPE Jacket Shielded 100% Insulation Copper Power Cable 15kV and Type UL MV105 Shielded EPR Insulation PVC Jacket 133% Insulation Copper Power Cable 15kV have Ethylene propylene rubber (EPR) per ICEA S-97-682 with a semi-conducting insulation shield.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWhat are the regulations and uses of Type UL MV105 EPR Insulation CPE Jacket Shielded 100% Insulation Copper Power Cable 15kV and Type UL MV105 Shielded EPR Insulation PVC Jacket 133%Insulation Copper Power Cable 15kVunder specific temperature conditions?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe National Electric Code has allowed the use of Type UL MV105 EPR Insulation CPE Jacket Shielded 100% Insulation Copper Power Cable 15kV at 90°C for continuous operation, 130°C for emergency overload conditions and 250°C for short circuit conditions.\u003c\/p\u003e\n\u003cp\u003eFor Type UL MV105 Shielded EPR Insulation PVC Jacket 133% Insulation Copper Power Cable 15kV, its 105°C for continuous operation, 140°C for emergency overload conditions, and 250°C for short circuit conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWhat are the national and international standards to which Type UL MV105 EPR Insulation CPE Jacket Shielded 100% Insulation Copper Power Cable 15kV and Type UL MV 105 Shielded EPR Insulation PVC Jacket 133%Insulation Copper Power Cable 15kVconform?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBoth the Power Cables conforms to all major national and international technical standards of the industry such as:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eICEA S-93-639\u003c\/li\u003e\n\u003cli\u003eICEA S-97-682\u003c\/li\u003e\n\u003cli\u003eNEMA WC74\u003c\/li\u003e\n\u003cli\u003eAEIC CS8\u003c\/li\u003e\n\u003cli\u003eFederal Specification J-C-30B\u003c\/li\u003e\n\u003cli\u003eUL Standard 1072\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27521993277540,"sku":"NNC5209X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/Product37.png?v=1762459812"},{"product_id":"type-ul-mv105-shielded-epr-insulation-cpe-jacket-133","title":"TYPE UL MV105 SHIELDED EPR INSUL CPE JACKET 133% COPPER POWER CABLE 15kV","description":"\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch2\u003eTYPE UL MV105 SHIELDED EPR INSUL CPE JACKET 133% COPPER POWER CABLE 15kV\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eApplications:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe mv105 copper cable is an electrical wire used for power circuits up to 15,000 Volts when fixed in open air, conduit, or duct; in applications such as chemical plants, refineries, steel mills, industrial plants, commercial buildings, utility substations, and generating stations. The National Electric Code accepts this electrical cable for uses within 105°C for continuous operation, 140°C for emergency overload conditions, and 250°C for short circuit conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eAlso Known As:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eMedium voltage power cables, mv power cable, mv105 cable, mv105, erp power cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eStandards:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eNational Electric Code (NEC)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eUL 1072\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eUL listed as Type MV-105 for use in accordance with NEC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eUL 1685\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eOSHA Acceptable\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eConstruction\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eConductors:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe MV power cable conductor is made of copper and has a conductor shield \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003ewith soft bare annealed copper per ASTM B-3,\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e Class B stranding per ASTM B-8 (compressed), or ASTM B-496 (compact).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eInsulation:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eA strong and enduring ethylene-propylene rubber (EPR) is used as the insulation system. The good thing about this insulation is how friendly it is to human hands since it is a rubber, a material that tends to be soft but guarantees profound and reliable safety wires. This insulation is also environmentally friendly, it doesn’t contain any toxins which can cause harm to human, animals, and plants health.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eShield:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eShielded wires of six rigid copper longitudinally embedded in an exterior semi-conducting CPE jacket per ICEA S-97-682.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eJacket:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe jacket of this ERP power cable is made of Thermoset Chlorinated Polyethylene (TS CPE).\u003c\/span\u003e\u003c\/p\u003e\n\u003caddress\u003e\u003cstrong\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/address\u003e[\/short]\n\u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eFrequently Asked Questions - TYPE UL MV105 EPR INSULATION CPE JACKET SHIELDED 100% INSULATION COPPER POWER CABLE 15kVand TYPE UL MV105 SHIELDED EPR INSULATION PVC JACKET 133% INSULATION COPPER POWER CABLE 15kV\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003eWhat are the specific applications of Type UL MV105 EPR Insulation CPE Jacket Shielded 100% Insulation Copper Power Cable 15kV and Type UL MV105 Shielded EPR Insulation PVC Jacket 133%Insulation Copper Power Cable 15kV?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThese power cablesare suitable for corrosive environments in power circuits up to 15,000V which are installed in open air, conduit \u0026amp; duct; cable tray when CT rated, in wet and dry conditions. These power cables are appropriate for chemical plants, refineries, steel mills, industrial plants, commercial buildings, utility substations and general stations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003eWhat is the type of conductor used for Type UL MV105 EPR Insulation CPE Jacket Shielded 100% Insulation Copper Power Cable 15kV and Type UL MV105 Shielded EPR Insulation PVC Jacket 133%Insulation Copper Power Cable 15kV?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe power cables have a semi-conducting conductor shield, with a compacted soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003eWhat is the insulation used for Type UL MV105 EPR Insulation CPE Jacket Shielded 100% Insulation Copper Power Cable 15kV and Type UL MV105 Shielded EPR Insulation PVC Jacket  133%Insulation Copper Power Cable 15kV?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBoth the power cablesType UL MV105 EPR Insulation CPE Jacket Shielded 100% Insulation Copper Power Cable 15kV and Type UL MV105 Shielded EPR Insulation PVC Jacket 133% Insulation Copper Power Cable 15kV have Ethylene propylene rubber (EPR) per ICEA S-97-682 with a semi-conducting insulation shield.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003eWhat are the regulations and uses of Type UL MV105 EPR Insulation CPE Jacket Shielded 100% Insulation Copper Power Cable 15kV and Type UL MV105 Shielded EPR Insulation PVC Jacket 133%Insulation Copper Power Cable 15kVunder specific temperature conditions?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe National Electric Code has allowed the use of Type UL MV105 EPR Insulation CPE Jacket Shielded 100% Insulation Copper Power Cable 15kV at 90°C for continuous operation, 130°C for emergency overload conditions and 250°C for short circuit conditions.\u003c\/p\u003e\n\u003cp\u003eFor Type UL MV105 Shielded EPR Insulation PVC Jacket 133% Insulation Copper Power Cable 15kV, its 105°C for continuous operation, 140°C for emergency overload conditions, and 250°C for short circuit conditions.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003eWhat are the national and international standards to which Type UL MV105 EPR Insulation CPE Jacket Shielded 100% Insulation Copper Power Cable 15kV and Type UL MV 105 Shielded EPR Insulation PVC Jacket  133%Insulation Copper Power Cable 15kVconform?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBoth the Power Cables conforms to all major national and international technical standards of the industry such as:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eICEA S-93-639\u003c\/li\u003e\n\u003cli\u003eICEA S-97-682\u003c\/li\u003e\n\u003cli\u003eNEMA WC74\u003c\/li\u003e\n\u003cli\u003eAEIC CS8\u003c\/li\u003e\n\u003cli\u003eFederal Specification J-C-30B\u003c\/li\u003e\n\u003cli\u003eUL Standard 1072\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27521993932900,"sku":"NNC5218X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/Product38.png?v=1762459818"},{"product_id":"type-ul-mv105-single-conductor-shielded-epr-insulation-pvc-jacket-copper","title":"Type UL MV105 Single Conductor PVC Jacket Copper Power Cable 24kV \/ 35kV","description":"\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch2\u003eType UL MV105 Single Conductor PVC Jacket Copper Power Cable 24kV \/ 35kV\u003c\/h2\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003eApplications:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003eThe mv105 copper cable is an electrical wire used for power circuits up to 24,000\/35,000 Volts when fixed in open air, conduit, or duct; in applications such as chemical plants, refineries, steel mills, industrial plants, commercial buildings, utility substations, and generating stations. The National Electric Code accepts this electrical cable for uses within 105°C for continuous operation, 140°C for emergency overload conditions, and 250°C for short circuit conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003eAlso Known As:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003eMedium voltage power cables, mv power cable, mv105 cable, mv105, pvc jacket. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003eStandards:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003eICEA S-93-639\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003eNEMA WC74\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003eAEIC CS8\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003eFederal Specification J-C-30B\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003eConstruction\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003eConductors:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003eThe MV power cable conductor is made of copper with a semi-conducting conductor shield: soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed), or ASTM B-496 (compact).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003eInsulation:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003eA strong and enduring ethylene-propylene rubber (EPR) is used as the insulation system. The good thing about this insulation is how friendly it is to human hands since it is a rubber, a material that tends to be soft but guarantees profound and reliable safety wires. This insulation is also environmentally friendly, it doesn’t have some toxins which can cause harm to human, animals, and plants health.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003eJacket:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003eReinforced insulation is provided by a PVC jacket, which is \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\" style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003esunlight-resistant, per ICEA S-97-682 and UL Standard 1072.\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr\u003e [\/short]\n\u003cp\u003e\u003cstrong\u003eFrequently Asked Questions - TYPE UL MV105 SINGLE CONDUCTOR SHIELDED EPR INSULATION PVC JACKET COPPER POWER CABLE 24kV \/ 35kV Power Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003eWhat are the specific applications of Type UL MV105 Single Conductor Shielded EPR Insulation PVC Jacket Copper24kV\/35kV Power Cables?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eType UL MV105 Single Conductor Shielded EPR Insulation PVC Jacket Copper 24kV\/35kV Power Cables are suitable for corrosive environments in power circuits up to 24,000V \/ 35,000V which are installed in open air, conduit \u0026amp; duct; cable tray when CT rated, in wet and dry conditions. These power cables are appropriate for chemical plants, refineries, steel mills, industrial plants, commercial buildings, utility substations and general stations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003eHow is the Type UL MV105 Single Conductor Shielded EPR Insulation PVC Jacket Copper24kV\/35kV Power Cable constructed? What materials are used for conductors and insulators?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eType UL MV105 Single Conductor Shielded EPR Insulation PVC Jacket Copper 24kV\/35kV Power Cables is constructed using a semi-conducting conductor shield of soft bare annealed copper which qualify the ASTM B-3. It also has Class B stranding as per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\n\u003cp\u003eFor insulation, these power cables use a semi-conducting insulation shield of Ethylene propylene rubber (EPR) that qualifies the ICEA S-97-682 standard.\u003c\/p\u003e\n\u003cp\u003eThey have an uncoated copper tape with a minimum 12.5% overlap per ICEA S-97-682 for shielding. It also has a sunlight resistant PVC Jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003eWhat are the regulations and uses of  Type UL MV105 Single Conductor Shielded EPR Insulation PVC Jacket Copper24kV\/35kV Power Cables under specific temperature conditions?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe National Electric Code has allowed the use of Type UL MV105 Single Conductor Shielded EPR Insulation PVC Jacket Copper 24kV\/35kV Power Cables at 105°C for continuous operation, 140°C for emergency overload conditions and 250°C for short circuit conditions.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003eWhat sizes of power cables are available in Type UL MV105 Single Conductor Shielded EPR Insulation PVC Jacket Copper24kV\/35kV Power Cables range?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eType UL MV105 Single Conductor Shielded EPR Insulation PVC Jacket Copper 24kV\/35kV Power Cables are available through 8 AWG – 1000 MCM. Specifics can be found at \u003ca href=\"http:\/\/www.crownindustrial.com\/med-epr-sheild-24-35-kv.html\"\u003ehttp:\/\/www.crownindustrial.com\/med-epr-sheild-24-35-kv.html\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003eWhat type of Jacket does the Type UL MV105 Single Conductor Shielded EPR Insulation PVC Jacket Copper24kV\/35kV Power Cables have?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor Jacket, Type UL MV105 Single Conductor Shielded EPR Insulation PVC Jacket Copper 24kV\/35kV Power Cables are having sunlight resistant PVC as per the standards of ICEA S-97-682 and UL Standard 1072.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003eWhat are the national and international standards to which Type UL MV105 Single Conductor Shielded EPR Insulation PVC Jacket Copper24kV\/35kV Power Cables conform?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eType UL MV105 Single Conductor Shielded EPR Insulation PVC Jacket Copper 24kV\/35kV Power Cables conforms to all major national and international technical standards of the industry such as:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eICEA S-93-639\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eNEMA WC74\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAEIC CS8\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eFederal Specification J-C-30B\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27521997242468,"sku":"NNC5227X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/Product40.png?v=1762459824"},{"product_id":"mv105-three-conductor-non-shielded-epr-insulation-pvc-jacket-copper","title":"MV105 Three Conductor Non-shielded PVC Jacket Copper Power Cable 2.4KV","description":"\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch2\u003eMV105 Three Conductor Non-shielded PVC Jacket Copper Power Cable 2.4KV\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eApplications:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe mv105 copper cable is an electrical wire used for power circuits up to 2,400 Volts when fixed in open air, conduit, or duct; in applications such as chemical plants, refineries, steel mills, industrial plants, commercial buildings, utility substations, and generating stations. The National Electric Code accepts this electrical cable for uses within 105°C for continuous operation, 140°C for emergency overload conditions, and 250°C for short circuit conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eAlso Known As:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eMedium voltage power cables, mv power cable, mv105 cable, mv105, pvc jacket.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eStandards:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eICEA S-93-639\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eNEMA WC74\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eAEIC CS8\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cspan style=\"font-weight: 400;\"\u003eFederal Specification J-C-30B\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eConstruction\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eConductors:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe MV power cable conductor is made of copper, it is Class B stranding per ASTM B-8 (compressed), or ASTM B-496 (compact), with a semi-conducting conductor shield.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eInsulation:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eA strong and enduring ethylene-propylene rubber (EPR) is used as the insulation system. The good thing about this insulation is how friendly it is to human hands since it is a rubber, a material that tends to be soft but guarantees profound and reliable safety wires. This insulation is also environmentally friendly, it doesn’t have some toxics which can cause harm to human, animals, and plants health.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eJacket:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eReinforced insulation is provided by a PVC jacket, which is \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003esunlight-resistant, per ICEA S-97-682 and UL Standard 1072.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cspan style=\"font-size: 1.4em;\"\u003e[\/short]\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eMV105 Three Conductor Non-Shielded EPR Insulation PVC Jacket Copper Power Cable 2.4Kv\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA power cable whose versatility is unquestionable and service is beyond doubt. It is worth your choice because at Nassau National Cable, you only get the top quality of such power cables. Its profound specifications comprise of its PVC Jacket, EPR insulation, its 133% insulation level and most of all copper conductor. This is a three conductor cable.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cb\u003eConductor\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe power cable is made from soft and annealed bare \u003ca href=\"https:\/\/www.nassaunationalcable.com\/wire-and-cable\/copper\/bare.html\"\u003ecopper conductor\u003c\/a\u003e. The high electrical conductivity feature of copper makes the cable highly regarded as one of the best power cables. To increase variety and enhance specialization, the cable conductor is designed into two configurations: Stranded and Compact. Stranded conductor is more flexible hence fits applications which involve a lot of movements while the compact type has more strength hence appropriate for systems where cable strength is fundamental. Upon placing your order and describing the nature of your applications, you will be advised appropriate about the suitable type to use.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cb\u003eInsulation\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWhat makes the cable sturdier, stable, stronger and reliable is the prominent insulation made from ethylene propylene rubber. The insulator is reinforced by a semi-conductor insulation shield as per the ICEA S-97-682 standards. This rubber is admired for its convenience, strength and friendliness to users.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cb\u003eJacket\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eA sunlight resistant jacket made from PVC according to ICEA S-97-682 and UL Standard 1072, helps in reinforcing the security features for the cable.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eApplications\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA power circuit whose power utility is up to 2.4 kilo Volts can appropriately be wired using this cable. Though Non-shielded, the power cable is designed with versatility and tough insulation hence serves in all environments which are prone to corrosive agents. Installations like open air, conduit and duct methods requires stronger and quality cables like Non Shielded EPR PVC insulation power cable.\u003c\/p\u003e\n\u003cp\u003eMain uses for this power cable includes: Use in the refineries and chemical plants where a lot of corrosive and toxic substances are released. The cable is also used for: Steel mills, Commercial buildings, industrial plants, power substations and generation centers.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eOperation\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eNational Electric Code authenticates the use of this cable. It proceeds to define how the cable can operate efficiently within a temperature range of up to 105 degrees continuously while under emergence overloads, it can sustain up to a range of 140 degrees Celsius. Shorts circuits are unforeseen occurrences; this cable can save your system provided a temperature of 250\u003csup\u003e0\u003c\/sup\u003eC is not exceeded.\u003c\/p\u003e\n\u003cp\u003eCable standardization:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNEMA approves the cable through NEMA WC74\u003c\/li\u003e\n\u003cli\u003eAEIC CS8\u003c\/li\u003e\n\u003cli\u003eFederal Specification J-C-30B\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eConclusion\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe three power cables talked about in this post have unique and significant features that mark each one of them. It is however true that all of them have quality and proficiency since they are products of high technical skills and thorough mechanical, electrical and lab tests. The cables having been made from renown cable manufacturers such as General Cable. This should leave you with no doubt about their proficiencies and performance. Power cables should have high electrical conductivity being that the cables are made from copper, their conductivity is top notch.\u003c\/p\u003e\n\u003cp style=\"text-align: left;\" data-mce-style=\"text-align: left;\"\u003e\u003cstrong\u003eQuestion and Answer:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\" data-mce-style=\"text-align: center;\"\u003e\u003cstrong\u003eFrequently Asked Questions - MV105 THREE CONDUCTOR SHIELDED EPR INSULATION PVC JACKET 5KV 133% 8KV 100% INSULATION and MV105 THREE CONDUCTOR NON-SHIELDED EPR INSULATION PVC JACKET COPPER POWER CABLE 2.4kV\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\" data-mce-style=\"text-decoration: underline;\"\u003eWhat are the specific applications of MV105 Three Conductor Non-Shielded EPR Insulation PVC Jacket Copper2.4kV Power Cables and MV105 Three Conductor Shielded EPR Insulation PVC Jacket 5kV 133%8kV 100% Power Cables?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMV105 Three Conductor Non-Shielded EPR Insulation PVC Jacket Copper 2.4kV Power Cables are suitable for corrosive environments in power circuits up to 2400V which are installed in open air, conduit \u0026amp; duct; cable tray when CT rated, in wet and dry conditions. These power cables are appropriate for chemical plants, refineries, steel mills, industrial plants, commercial buildings, utility substations and general stations.\u003c\/p\u003e\n\u003cp\u003eMV105 Three Conductor Shielded EPR Insulation PVC Jacket 5kV 133%  8kV 100% Power Cables also are used in similar situations, just that it can be used in power circuits up to 5,000V \u0026amp; 8,000V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\" data-mce-style=\"text-decoration: underline;\"\u003eWhat is the difference between MV105 Three Conductor Non-Shielded EPR Insulation PVC Jacket Copper2.4kV Power Cables and MV105 Three Conductor Shielded EPR Insulation PVC Jacket 5kV 133%8kV 100% Power Cables?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe main difference between bothcables lies in the fact that MV105 Three Conductor Shielded EPR Insulation PVC Jacket 5kV 133%  8kV 100% Power Cables have a ground conductor with soft bare annealed compressed copper per ASTM B-3, and with stranding of Class B per ASTM B-8 sized in accordance to UL Standard 1072.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\" data-mce-style=\"text-decoration: underline;\"\u003eWhat is the insulation used for MV105 Three Conductor Non-Shielded EPR Insulation PVC Jacket Copper2.4kV Power Cables and MV105 Three Conductor Shielded EPR Insulation PVC Jacket 5kV 133%8kV 100% Power Cables?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBoth the power cables have Ethylene propylene rubber (EPR) per ICEA S-97-682 with a semi-conducting insulation shield.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\" data-mce-style=\"text-decoration: underline;\"\u003eWhat are the regulations and uses of  MV105 Three Conductor Non-Shielded EPR Insulation PVC Jacket Copper2.4kV Power Cables and MV105 Three Conductor Shielded EPR Insulation PVC Jacket 5kV 133%8kV 100% Power Cables under specific temperature conditions?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe National Electric Code has allowed the use of both thepowercables at 105°C for continuous operation, 140°C for emergency overload conditions and 250°C for short circuit conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\" data-mce-style=\"text-decoration: underline;\"\u003eWhat are the national and international standards to which MV105 Three Conductor Non-Shielded EPR Insulation PVC Jacket Copper2,4kV Power Cables and MV105 Three Conductor Shielded EPR Insulation PVC Jacket 5kV 133%8kV 100% Power Cables conform?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBoth MV105 Three Conductor Non-Shielded EPR Insulation PVC Jacket Copper 2,4kV Power Cables and MV105 Three Conductor Shielded EPR Insulation PVC Jacket 5kV 133% 8kV 100% Power Cables conforms to all major national and international technical standards of the industry such as:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eICEA S-93-639\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eNEMA WC74\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAEIC CS8\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eFederal Specification J-C-30B\u003c\/strong\u003e\u003c\/li\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27521998028900,"sku":"NNC5236X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/Product27.png?v=1762459830"},{"product_id":"mv-105-power-cable-w-ground-5kv-8kv-epr-pvc-insulation-copper-tape-shield-133-100-insulation-level","title":"MV-105 Power Cable w\/ Ground, 5kV\/8kV, EPR\/PVC Insulation, Copper Tape Shield, 133%\/100% Insulation Level","description":"\u003cp\u003e[short]\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003eMV-105 Power Cable w\/ Ground, 5kV\/8kV, EPR\/PVC Insulation, Copper Tape Shield, 133%\/100% Insulation Level\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eApplications:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe mv105 copper cable is an electrical wire used for power circuits up to 5,000 Volts when fixed in open air, conduit, or duct; in applications such as chemical plants, refineries, steel mills, industrial plants, commercial buildings, utility substations, and generating stations. The National Electric Code accepts this electrical cable for uses within 105°C for continuous operation, 140°C for emergency overload conditions, and 250°C for short circuit conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eAlso Known As:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eMedium voltage power cables, mv power cable, mv105 cable, mv105, pvc jacket.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eStandards:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eICEA S-93-639\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eNEMA WC74\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eAEIC CS8\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eFederal Specification J-C-30B \u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eConstruction\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eConductors:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe MV power cable conductor is made of copper and has a conductor shield \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003ewith soft bare annealed copper per ASTM B-3,\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e Class B stranding per ASTM B-8 (compressed), or ASTM B-496 (compact).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eInsulation:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eA strong and enduring ethylene-propylene rubber (EPR) is used as the insulation system. The good thing about this insulation is how friendly it is to human hands since it is a rubber, a material that tends to be soft but guarantees profound and reliable safety wires. This insulation is also environmentally friendly, it doesn’t contain any toxins which can cause harm to human, animals, and plants health.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eJacket:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eReinforced insulation is provided by a PVC jacket, which is \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003esunlight-resistant, per ICEA S-97-682 and UL Standard 1072.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e [\/short]\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eMV105 THREE CONDUCTOR 5KV POWER CABLE\u003c\/p\u003e\n\u003cp\u003eThis cable is meant for heavy duty applications in corrosive environments given that it has three conductors. It has a voltage rating of 5000 volts and 8000 volts. The operating temperature of this cable is slightly higher compared to the previous cables. It normally operates at 105 degrees Celsius but in case of an emergency overload it can withstand temperatures up to 140 degrees Celsius and if a short circuit occurs it can withstand a temperature of 250 degrees Celsius. It’s mainly used in chemical plants, industrial plants, refineries and commercial buildings.\u003c\/p\u003e\n\u003cp\u003eThis cable has three \u003ca href=\"https:\/\/www.nassauelectrical.com\/products\/copper-building-wire\"\u003ecopper conductors\u003c\/a\u003e and a semi-conducting shield on the conductors. Among the three conductors is a ground conductor which also withholds current under normal operation of the cable. The conductors on this cable are also stranded which enhances flexibility of the conductors. The insulation is constructed from Ethylene propylene rubber (EPR) which also has a semi-conducting shield added to it. The insulation for the 5000 volt wire has 100 % coverage while for the 8000 volt option the coverage is 133%.\u003c\/p\u003e\n\u003cp\u003eAn overall shield is added to prevent mechanical and electromagnetic interferences from affecting the inner parts of the cable. The overall shield is made from uncoated copper tape. The cable has an outer jacket which conceals the inner components of the cable and is made from PVC material.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eIndustrial ratings and approvals\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e It’s always advisable to buy products that have been tested and proven safe for use. Products are usually tested to ensure that they are in good condition and safe to use by the public and it also proves that the product is genuine. Many suppliers out their sell products that have not been tested by international agencies but since we at Nassau national cable care about you and your safety we ensure our products are tested. Our products are tested by the following agencies;\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNational Electric Code (NEC)\u003c\/li\u003e\n\u003cli\u003eFederal Specification J-C-30B\u003c\/li\u003e\n\u003cli\u003eICEA S-93-639\u003c\/li\u003e\n\u003cli\u003eNEMA WC74\u003c\/li\u003e\n\u003cli\u003eAEIC CS8\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWith the above standards you can trust that our products are genuine\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eWhy go for the medium voltage power cable?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThis cable has numerous benefits that come with it to the consumer. First and foremost this cable can be used in a wide range of applications to supply power including corrosive environments. It also has outstanding features that make it effective in performing its functions which includes durability and flexibility. This cable can also be recycled hence it can be utilized elsewhere in case it wears out which can take a lifetime.\u003c\/p\u003e\n\u003cp\u003eThis cable can be found in many electrical outlets worldwide but before you settle on a supplier it’s advisable to ensure the products are genuine. For more information on this cable and other wire products get in touch with us via our live chat on our website and we will gladly respond to your queries. I hope you found this review helpful.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion and Answer:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFrequently Asked Questions - MV105 THREE CONDUCTOR SHIELDED EPR INSULATION PVC JACKET 5KV 133% 8KV 100% INSULATION and MV105 THREE CONDUCTOR NON-SHIELDED EPR INSULATION PVC JACKET COPPER POWER CABLE 2.4kV\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWhat are the specific applications of MV105 Three Conductor Non-Shielded EPR Insulation PVC Jacket Copper2.4kV Power Cables and MV105 Three Conductor Shielded EPR Insulation PVC Jacket 5kV 133%8kV 100% Power Cables?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMV105 Three Conductor Non-Shielded EPR Insulation PVC Jacket Copper 2.4kV Power Cables are suitable for corrosive environments in power circuits up to 2400V which are installed in open air, conduit \u0026amp; duct; cable tray when CT rated, in wet and dry conditions. These power cables are appropriate for chemical plants, refineries, steel mills, industrial plants, commercial buildings, utility substations and general stations.\u003c\/p\u003e\n\u003cp\u003eMV105 Three Conductor Shielded EPR Insulation PVC Jacket 5kV 133% 8kV 100% Power Cables also are used in similar situations, just that it can be used in power circuits up to 5,000V \u0026amp; 8,000V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the difference between MV105 Three Conductor Non-Shielded EPR Insulation PVC Jacket Copper2.4kV Power Cables and MV105 Three Conductor Shielded EPR Insulation PVC Jacket 5kV 133%8kV 100% Power Cables?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe main difference between bothcables lies in the fact that MV105 Three Conductor Shielded EPR Insulation PVC Jacket 5kV 133% 8kV 100% Power Cables have a ground conductor with soft bare annealed compressed copper per ASTM B-3, and with stranding of Class B per ASTM B-8 sized in accordance to UL Standard 1072.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the insulation used for MV105 Three Conductor Non-Shielded EPR Insulation PVC Jacket Copper2.4kV Power Cables and MV105 Three Conductor Shielded EPR Insulation PVC Jacket 5kV 133%8kV 100% Power Cables?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBoth the power cables have Ethylene propylene rubber (EPR) per ICEA S-97-682 with a semi-conducting insulation shield.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWhat are the regulations and uses of MV105 Three Conductor Non-Shielded EPR Insulation PVC Jacket Copper2.4kV Power Cables and MV105 Three Conductor Shielded EPR Insulation PVC Jacket 5kV 133%8kV 100% Power Cables under specific temperature conditions?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe National Electric Code has allowed the use of both thepowercables at 105°C for continuous operation, 140°C for emergency overload conditions and 250°C for short circuit conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWhat are the national and international standards to which MV105 Three Conductor Non-Shielded EPR Insulation PVC Jacket Copper2,4kV Power Cables and MV105 Three Conductor Shielded EPR Insulation PVC Jacket 5kV 133%8kV 100% Power Cables conform?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBoth MV105 Three Conductor Non-Shielded EPR Insulation PVC Jacket Copper 2,4kV Power Cables and MV105 Three Conductor Shielded EPR Insulation PVC Jacket 5kV 133% 8kV 100% Power Cables conforms to all major national and international technical standards of the industry such as:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eICEA S-93-639\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eNEMA WC74\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAEIC CS8\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eFederal Specification J-C-30B\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27521998946404,"sku":"NNC5249X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/Product32.png?v=1762459840"},{"product_id":"mv-90-2-4kv-single-conductor-epr-cpe-unshielded-power-cable","title":"MV-90 2.4KV Single Conductor EPR\/CPE Unshielded Power Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HW201_2.pdf?v=1729778615\" width=\"\" height=\"\" type=\"application\/pdf\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMV-90 2.4KV Single Conductor EPR\/CPE Unshielded Power Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor use in caustic environments in power circuits up to 2.4kV when installed in open air, conduit, duct, cable tray when CT rated, in wet and dry locations. Used for applications in chemical plants, refineries, steel mills, industrial plants, commercial buildings, utility substations and generating stations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Know As:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMedium voltage power cables, Power cable, MV90 Cables, EPR Power cable, CPE Jacketed Cables, Medium Voltage Cables, 90C MV Cables.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Compressed, soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8, with a semi-conducting conductor shield\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eEthylene propylene rubber (EPR) per ICEA standards\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e XL-CPE per ICEA standards\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e UL and IEEE (70,000 BTU\/hr) Flame Test for CT-listed sizes 1\/0 AWG and larger\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStrandads:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e• ICEA S-96-659\u003cbr\u003e• UL Standard 1072\u003cbr\u003e• NEMA WC71\u003cbr\u003e• CT rating must be requested, CT ratings are available on sizes 1\/0 AWG and larger.\u003cbr\u003e• PVC jacket available upon request\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27783068156004,"sku":"NNC33094X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/Product28.png?v=1762478026"},{"product_id":"mv105-15kv-three-conductor-epr-pvc-power-cable","title":"MV105 15kV Three Conductor EPR\/PVC Power Cable","description":"[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Three_Conductor_15KV_Shielded_MV-105.pdf?v=1624868534\"\u003e [\/pdf] [short]\n\u003ch2\u003eMV105 15kV Three Conductor EPR\/PVC Power Cable\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eApplications:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe mv105 copper cable is an electrical wire used for power circuits up to 15,000 Volts when fixed in open air, conduit, or duct; in applications such as chemical plants, refineries, steel mills, industrial plants, commercial buildings, utility substations, and generating stations. The National Electric Code accepts this electrical cable for uses within 105°C for continuous operation, 140°C for emergency overload conditions, and 250°C for short circuit conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eAlso Known As:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eMedium voltage power cables, mv power cable, mv105 cable, mv105, erp power cable, pvc jacket.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eStandards:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cb\u003eIndustry\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: National Electrical Code (NEC). UL 1072. ICEA S-93-639\/NEMA WC74. ICEA S-97-682. AEIC CS8. UL listed as type MV-105 for use in accordance with the NEC. Sizes 1\/0 AWG and larger are listed and marked \"Sunlight-Resistant FOR CT USE\" in accordance with NEC.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cb\u003eFlame Test\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: UL 1685 (70,000 BTU\/hr)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cb\u003eOptional Flame Test\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: IEEE 1202 (70,000 BTU\/hr)\/CSA FT4. ICEA T-29-520 (210,000 BTU\/hr.)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cb\u003eOther\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: EPA 40 CFR, Part 261, for leachable lead content per TCLP. OSHA acceptable.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eConstruction\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eConductors:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe MV power cable conductor is made of copper and has a conductor shield \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003ewith soft bare annealed copper per ASTM B-3,\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e Class B stranding per ASTM B-8 (compressed), or ASTM B-496 (compact).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eInsulation:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eA strong and enduring ethylene-propylene rubber (EPR) is used as the insulation system. The good thing about this insulation is how friendly it is to human hands since it is a rubber, a material that tends to be soft but guarantees profound and reliable safety wires. This insulation is also environmentally friendly, it doesn’t contain any toxins which can cause harm to human, animals, and plants health.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eInsulation Shield:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThermoset semi-conducting polymeric layer free stripping from insulation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eMetallic Shield:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e5 mil annealed copper tape with an overlap of 25%.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eJacket:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eReinforced insulation is provided by a PVC jacket, which is \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003esunlight-resistant, per ICEA S-97-682 and UL Standard 1072.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eClass B Compact concentric strand soft drawn annealed copper per ASTM\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNatural high dielectric strength EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eExtruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eExtruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMetalic Shield:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHelically applied non-magnetic copper tape(s) over the insulation shield with a minimum overlap of 15%. A Mylar ribbon is longitudinally applied under the copper tape shield for phase identification -1C w\/Red, 1C w\/Blue, and 1C w\/Black.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding Conductors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBare Stranded copper conductor, one in each interstice, per UL, ICEA, and ASTM.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAssembly:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePhase identified shielded conductors cabled with fillers and grounding conductors (as specified), forming a firm and cylindrical cable core. A binder tape is applied to maintain core symmetry and mechanical stability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHigh strength and high crush resistant Airbag Layer extruded over the core assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA layer of Drylam which consists of aluminum tape and a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSunlight resistant polyvinyl chloride (PVC) jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eICEA S-93-639\/NEMA WC74 Type MV 105 UL 1072 For CT USE, Direct Buried, Sunlight Resistant, IEEE 383 Flame Test IEEE 1202 Flame Test ICEA T-29-520 at 210,000 BTU\/hr MSHA Type MP\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27783069139044,"sku":"NNC33105X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/Picsart_22-07-20_14-55-28-348.jpg?v=1762478032"},{"product_id":"prysmian-airguard-mv105-15kv-3c-epr-pvc-133-copper-medium-voltage-power-cable","title":"Prysmian Airguard MV105 15kV 3C EPR\/PVC 133% Copper Medium Voltage Power Cable","description":"\u003cstyle type=\"text\/css\"\u003e\u003c!--\ntd {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}\n--\u003e\u003c\/style\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003ePrysmian Airguard MV105 15kV 3C EPR\/PVC 133% Copper Medium Voltage Power Cable\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003ePrysmian Airguard Cable has three conductor cables with stranded copper conductors, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, cabled with fillers and grounding conductors, overall binder tape, foamed polymeric layer for superior mechanical protection, longitudinally applied tape, extruded oil and hydrocarbon resistant polymeric layer, and overall sunlight resistant PVC jacket. Prysmian’s patented AIRGUARD cable is a direct replacement for continuously corrugated and welded armored cables with 5X the impact performance and 2X-3X the sidewall bearing pressure limit. Its enables longer pulls than with Continuously Corrugated and Welded type cables.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAlso known as:\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003ePrysmian Airguard Cable, \u003cspan\u003ePrysmian MV 105 Cable, Prysmian 15KV Cable, Prysmian Medium Voltage Power Cable, Prysmian Power Cable, Airguard Cable, EPR Cable, Medium Voltage Cable, Prysmian Welded Cable, Prysmian Corrugated Cable, Prysmian 133% Cable, Medium Voltage Power Cable.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConductors:\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003eSoft-drawn annealed copper per ASTM. Class B Compact concentric strand alloy 1350\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMetallic Shield:\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003eA mylar ribbon is longitudinally applied under the copper tape shield Helically applied non-magnetic copper tape(s) over the insulation shield with a nominal overlap of 25%. \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConductor Shield:\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eThe Extruded thermosetting semiconducting shield is free stripping from the conductor and bonded to the insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eNatural high dielectric strength EPROTENAX EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation Shield:\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eThe required balance between electrical integrity and ease of stripping. Extruded thermosetting semiconducting shield with controlled adhesion to the insulation provided.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGrounding Conductors:\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003eBare-stranded copper conductor per UL, ICEA, and ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAssembly:\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eA binder tape is applied to maintain core symmetry and mechanical stability. Phase-identified conductors cabled with fillers and grounding conductors, forming a firm and cylindrical cable core.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMechanical Protection:\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eHigh strength and high crush-resistant AIR BAG layer extruded over the core assembly.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eChemical Protection:\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eA layer of DRYLAM which consists of a 6mil longitudinally applied tape and a chemical-resistant extruded polymer layer is applied.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJacket:\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eSunlight and moisture-resistant polyvinyl chloride (PVC) jacket.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eStandards: \u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u003cbr\u003eUL 1072 ⁃ Type MV-105, For CT USE Direct Buried\/Sunlight Resistant\u003cbr\u003eIEEE ⁃ Flame Retardant\u003cbr\u003eUL 1277 TC-ER⁃ Exposed Run Rating\u003cbr\u003eCSA⁃ CSA FT4 Flame Test CSA Cold Impact\/Bend Test (-40C\u003cbr\u003eMSHA⁃ Type MP and Type MP-GC\u003cbr\u003eIEEE 1580⁃ Marine Shipboard Cable Rating\u003cbr\u003eABS⁃ American Bureau of Shipping Type Approval\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":42724039655578,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/66_f37b6736-8111-4205-ae9b-402311572ba8.png?v=1762512038"},{"product_id":"prysmian-airguard-mv105-5kv-3c-epr-pvc-133-medium-voltage-power-cable","title":"Prysmian Airguard MV105 5kV 3C EPR\/PVC 133% Medium Voltage Power Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Prysmian_Airguard.pdf?v=1666969345\" width=\"\" height=\"\" type=\"application\/pdf\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle data-mce-fragment=\"1\" type=\"text\/css\"\u003e\u003c!--\ntd {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}\n--\u003e\u003c\/style\u003e\n\u003ch2\u003ePrysmian Airguard MV105 5kV 3C EPR\/PVC 133% Medium Voltage Power Cable\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003ePrysmian Airguard Cable has three conductor cables with stranded copper conductors, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, cabled with fillers and grounding conductors, overall binder tape, foamed polymeric layer for superior mechanical protection, longitudinally applied aluminum tape, extruded oil and hydrocarbon resistant polymeric layer, and overall sunlight resistant PVC jacket. Prysmian’s patented AIRGUARD™ cable is a direct replacement for continuously corrugated and welded aluminum armored cables with 5X the impact performance and 2X-3X the sidewall bearing pressure limit. It enables longer pulls than with Continuously Corrugated and Welded type cables.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAlso known as:\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003ePrysmian Airguard Cable, \u003cspan data-mce-fragment=\"1\"\u003ePrysmian MV 105 Cable, Prysmian 5KV Cable, Prysmian Medium Voltage Power Cable, Prysmian Power Cable, Airguard Cable, EPR Cable, Medium Voltage Cable, Prysmian Welded Cable, Prysmian Corrugated Cable, Prysmian 133% Cable, Medium Voltage Power Cable.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConductors:\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003eSoft-drawn annealed copper per ASTM. Class B Compact concentric strand aluminum alloy 1350\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMetallic Shield:\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003eA mylar ribbon is longitudinally applied under the copper tape shield Helically applied non-magnetic copper tape(s) over the insulation shield with a nominal overlap of 25%. \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConductor Shield:\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eThe Extruded thermosetting semiconducting shield is free stripping from the conductor and bonded to the insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation:\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eNatural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation Shield:\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eThe required balance between electrical integrity and ease of stripping. Extruded thermosetting semiconducting shield with controlled adhesion to the insulation provided.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGrounding Conductors:\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003eBare-stranded copper conductor per UL, ICEA, and ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAssembly:\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eA binder tape is applied to maintain core symmetry and mechanical stability. Phase-identified conductors cabled with fillers and grounding conductors, forming a firm and cylindrical cable core.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMechanical Protection:\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eHigh strength and high crush-resistant AIR BAG layer extruded over the core assembly.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eChemical Protection:\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eA layer of DRYLAM™ which consists of a 6mil longitudinally applied aluminum tape and a chemical-resistant extruded polymer layer is applied.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJacket:\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eSunlight and moisture-resistant polyvinyl chloride (PVC) jacket.\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards: \u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cbr\u003e\u003cbr\u003eUL 1072 ⁃ Type MV-105, For CT USE Direct Buried\/Sunlight Resistant\u003cbr data-mce-fragment=\"1\"\u003eIEEE ⁃ Flame Retardant\u003cbr data-mce-fragment=\"1\"\u003eUL 1277 TC-ER⁃ Exposed Run Rating\u003cbr data-mce-fragment=\"1\"\u003eCSA⁃ CSA FT4 Flame Test CSA Cold Impact\/Bend Test (-40C\u003cbr data-mce-fragment=\"1\"\u003eMSHA⁃ Type MP and Type MP-GC\u003cbr data-mce-fragment=\"1\"\u003eIEEE 1580⁃ Marine Shipboard Cable Rating\u003cbr data-mce-fragment=\"1\"\u003eABS⁃ American Bureau of Shipping Type Approval\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":42724453417114,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/66_b0421b5f-e122-46d5-ac16-64c5b56752da.png?v=1759819205"},{"product_id":"medium-voltage-accessories","title":"Medium Voltage Accessories","description":"\u003cstyle type=\"text\/css\" data-mce-fragment=\"1\"\u003e\u003c!--\ntd {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}\n--\u003e\u003c\/style\u003e\n\u003cp\u003e\u003cstrong\u003eMedium Voltage Accessories\u003cbr\u003e\u003cbr\u003eApplication:\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e3M Cold Shrink Silicone Rubber Termination Kit QT-III 7620-T and 7690-T Series contain one-piece, non-skirted, silicone rubber terminations, qualified as IEEE Standard 48-1990 Class 1 for indoor and weather-protected applications. \u003cspan data-mce-fragment=\"1\"\u003eThe kits are designed for terminating solid dielectric shielded power cable rated 5–35 kV, with tape shield, wire shield, and UniShield® constructions. The termination assemblies consist of a tubular insulator, high dielectric constant (Hi-K) stress control tube*, conformable Hi-K stress controlling compound, and built-in silicone top seal. The insulator is made of a new dark gray silicone rubber with advanced tracking resistance and hydrophobic properties. 7620-T and 7621-T are designed and assembled with stress-controlling compounds only. The complete assembly is pre-stretched and loaded onto a removable core. The disposable core can be recycled.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAlso known as:\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eCold Shrink Silicone Rubber, Medium Voltage Accessories, silicone rubber terminations, non-skirted terminations, silicone sealing compounds, common solid dielectric insulations\u003cbr\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003eDetails:\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e• These terminations can be filed-tested by using normal cable testing procedures.\u003cbr\u003e• Provides a void-free seal to tape shield, wire shield, and UniShield® power cables.\u003cbr data-mce-fragment=\"1\"\u003e• Switchgear, transformer, motor lead, bus, and similar connections.\u003cbr\u003e• One-piece versatile design, allowing quick installation and accommodating a wide range of cable sizes\u003cbr\u003e• Non-tracking, molded, silicone rubber insulation offers durability\u003cbr\u003e• Hi-K stress control: specially formulated high dielectric constant material minimizes surfaces stress by more uniformly distributing the electrical field over the entire surface of the insulator\u003cbr\u003e• Silicone rubber insulators, EPDM stress control tubes, stress controlling compounds, and silicone sealing compounds are compatible with all common solid dielectric insulations, such as polyethylene (PE), cross-linked polyethylene (XLPE), and ethylene propylene rubber (EPR)\u003cbr\u003e\u003cbr\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":42726577275034,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/PR21449V2_1024x1024_2x_ba748bc1-ab6f-4193-811c-37404c1f75f2.webp?v=1762512116"},{"product_id":"prysmian-airguard-mv105-8-kv-3c-epr-pvc-100-medium-voltage-power-cable","title":"Prysmian Airguard MV105 8 KV 3C EPR\/PVC 100% Medium Voltage Power Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Prysmian_Airguard.pdf?v=1666969345\" width=\"\" height=\"\" type=\"application\/pdf\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003ePrysmian Airguard MV105 8 KV 3C EPR\/PVC 100% Medium Voltage Power Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e• Prysmian’s patented AIRGUARD cable is a direct replacement for continuously corrugated and welded aluminum armored cables (*in Class 1 Div 2 locations) with 5X the impact performance and up to 3X the sidewall bearing pressure limit (at 3000 lbs per rad-ft) This enables longer pulls than with CCW type cables. Please call in regards to the product literature and performance testing and videos.\u003cbr\u003e• Three conductor cable with stranded copper or aluminum conductors, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, cabled with fillers and grounding conductors, overall binder tape, foamed polymeric AIR BAG™layer for superior mechanical protection, longitudinally applied aluminum tape, extruded oil and hydrocarbon resistant polymeric DRYLAM layer, and overall sunlight resistant PVC jacket. Suitable for Class I Division 2 locations.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-outline-level: 4;\" class=\"MsoNormal\" data-mce-style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-outline-level: 4;\"\u003ePrysmian Airguard MV105, MV105 8KV cable, 3C EPR\/PVC power cable, Medium voltage cable 8KV, Prysmian MV105 specs, Airguard medium voltage cable, EPR\/PVC insulated cable, 100% MV105 8KV cable, MV105 8KV 3-conductor, Prysmian medium voltage power cable,\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eClass B Compact concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003eHelically applied non-magnetic copper tape(s) over the insulation shield with a nominal overlap of 25%. A mylar ribbon is longitudinally applied under the copper tape shield for phase identification - 1C w\/ Red, 1C w\/ Blue, and 1C w\/ Black.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eExtruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eNatural high dielectric strength EPROTENAX EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eExtruded thermosetting semiconducting shield with controlled adhesion to\u003cbr\u003ethe insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eGrounding Conductors:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eBare stranded copper conductor per UL, ICEA, and ASTM.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eAssembly:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePhase identified conductors cabled with fillers and grounding conductors, forming a firm and cylindrical cable core. A binder tape is applied to maintain core symmetry and mechanical stability.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eHigh strength and high crush resistant AIR BAG layer extruded over the core assembly.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eA layer of DRYLAM which consists of a 6mil longitudinally applied aluminum tape and a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eSunlight and moisture resistant polyvinyl chloride (PVC) jacket.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eStandards: \u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eUL 1072 ⁃ Type MV-105, For CT USE Direct Buried\/Sunlight Resistant\u003cbr data-mce-fragment=\"1\"\u003eIEEE ⁃ Flame Retardant\u003cbr data-mce-fragment=\"1\"\u003eUL 1277 TC-ER⁃ Exposed Run Rating\u003cbr data-mce-fragment=\"1\"\u003eCSA⁃ CSA FT4 Flame Test CSA Cold Impact\/Bend Test (-40C\u003cbr data-mce-fragment=\"1\"\u003eMSHA⁃ Type MP and Type MP-GC\u003cbr data-mce-fragment=\"1\"\u003eIEEE 1580⁃ Marine Shipboard Cable Rating\u003cbr data-mce-fragment=\"1\"\u003eABS⁃ American Bureau of Shipping Type Approval\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":51644676735345,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/2_a963884e-7a7f-4730-b80c-ddf7c70fae13.png?v=1763007461"},{"product_id":"prysmian-airguard-mv105-25kv-3c-epr-pvc-133-medium-voltage-power-cable","title":"Prysmian Airguard MV105 25KV 3C EPR\/PVC 133% Medium Voltage Power Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Prysmian_Airguard.pdf?v=1666969345\" width=\"\" height=\"\" type=\"application\/pdf\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003ePrysmian Airguard MV105 25KV 3C EPR\/PVC 133% Medium Voltage Power Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e• Prysmian’s patented AIRGUARD cable is a direct replacement for continuously corrugated and welded aluminum armored cables (*in Class 1 Div 2 locations) with 5X the impact performance and up to 3X the sidewall bearing pressure limit (at 3000 lbs per rad-ft) This enables longer pulls than with CCW type cables. Please call in regards to the product literature and performance testing and videos.\u003cbr\u003e• Three conductor cable with stranded copper or aluminum conductors, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, cabled with fillers and grounding conductors, overall binder tape, foamed polymeric AIR BAG layer for superior mechanical protection, longitudinally applied aluminum tape, extruded oil and hydrocarbon resistant polymeric DRYLAM layer, and overall sunlight resistant PVC jacket. Suitable for Class I Division 2 locations.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePrysmian Airguard MV105 25KV, MV105 25KV cable, 3C EPR\/PVC 25KV power cable, 25KV medium voltage cable, Prysmian 25KV cable specs, Airguard 25KV medium voltage, 133% insulation MV105 cable, EPR\/PVC 25KV cable, MV105 25KV 3-conductor, Prysmian 25KV power cable\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eClass B Compact concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eHelically applied non-magnetic copper tape(s) over the insulation shield with a nominal overlap of 25%. A mylar ribbon is longitudinally applied under the copper tape shield for phase identification - 1C w\/ Red, 1C w\/ Blue, and 1C w\/ Black.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eExtruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eNatural high dielectric strength EPROTENAX EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eExtruded thermosetting semiconducting shield with controlled adhesion to\u003cbr\u003ethe insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eGrounding Conductors:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eBare stranded copper conductor per UL, ICEA, and ASTM.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eAssembly:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePhase identified conductors cabled with fillers and grounding conductors, forming a firm and cylindrical cable core. A binder tape is applied to maintain core symmetry and mechanical stability.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eHigh strength and high crush resistant AIR BAG layer extruded over the core assembly.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eA layer of DRYLAM which consists of a 6mil longitudinally applied aluminum tape and a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eSunlight and moisture resistant polyvinyl chloride (PVC) jacket.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eStandards: \u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e• UL 1072 ⁃ Type MV-105, For CT USE Direct Buried\/Sunlight Resistant\u003cbr data-mce-fragment=\"1\"\u003e• IEEE ⁃ Flame Retardant\u003cbr data-mce-fragment=\"1\"\u003e• UL 1277 TC-ER⁃ Exposed Run Rating\u003cbr data-mce-fragment=\"1\"\u003e• CSA⁃ CSA FT4 Flame Test CSA Cold Impact\/Bend Test (-40C\u003cbr data-mce-fragment=\"1\"\u003e• MSHA⁃ Type MP and Type MP-GC\u003cbr data-mce-fragment=\"1\"\u003e• IEEE 1580⁃ Marine Shipboard Cable Rating\u003cbr data-mce-fragment=\"1\"\u003e• ABS⁃ American Bureau of Shipping Type Approval\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":51644903391601,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/2_daa391be-d31e-4ead-bee6-262bd23f6f93.png?v=1759829444"},{"product_id":"prysmian-airguard-mv105-35kv-3c-epr-pvc-133-medium-voltage-power-cable","title":"Prysmian Airguard MV105 35KV 3C EPR\/PVC 133% Medium Voltage Power Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Prysmian_Airguard.pdf?v=1666969345\" width=\"\" height=\"\" type=\"application\/pdf\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003ePrysmian Airguard MV105 35KV 3C EPR\/PVC 133% Medium Voltage Power Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e• Prysmian’s patented AIRGUARD cable is a direct replacement for continuously corrugated and welded aluminum armored cables (*in Class 1 Div 2 locations) with 5X the impact performance and up to 3X the sidewall bearing pressure limit (at 3000 lbs per rad-ft) This enables longer pulls than with CCW type cables. Please call in regards to the product literature and performance testing and videos.\u003cbr\u003e• Three conductor cable with stranded copper or aluminum conductors, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, cabled with fillers and grounding conductors, overall binder tape, foamed polymeric AIR BAG layer for superior mechanical protection, longitudinally applied aluminum tape, extruded oil and hydrocarbon resistant polymeric DRYLAM layer, and overall sunlight resistant PVC jacket. Suitable for Class I Division 2 locations.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePrysmian MV105 35kV Cable, Airguard 35kV Power Cable, 3C EPR PVC 35kV Cable, Prysmian 35kV 133% insulation, 35kV MV105 Copper Cable,Medium Voltage Airguard Prysmian, 35kV 3 Conductor EPR Cable, Prysmian Medium Voltage 35kV, 35kV MV Cable for utilities, MV105 3C 35kV specification, 133% Insulated 35kV Cable, Prysmian 35kV power distribution cable\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eClass B Compact concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eHelically applied non-magnetic copper tape(s) over the insulation shield with a nominal overlap of 25%. A mylar ribbon is longitudinally applied under the copper tape shield for phase identification - 1C w\/ Red, 1C w\/ Blue, and 1C w\/ Black.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003eExtruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eNatural high dielectric strength EPROTENAX EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eExtruded thermosetting semiconducting shield with controlled adhesion to\u003cbr\u003ethe insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eGrounding Conductors:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eBare stranded copper conductor per UL, ICEA, and ASTM.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eAssembly:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePhase identified conductors cabled with fillers and grounding conductors, forming a firm and cylindrical cable core. A binder tape is applied to maintain core symmetry and mechanical stability.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eHigh strength and high crush resistant AIR BAG layer extruded over the core assembly.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eA layer of DRYLAM which consists of a 6mil longitudinally applied aluminum tape and a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eSunlight and moisture resistant polyvinyl chloride (PVC) jacket.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eStandards: \u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e• UL 1072 ⁃ Type MV-105, For CT USE Direct Buried\/Sunlight Resistant\u003cbr data-mce-fragment=\"1\"\u003e• IEEE ⁃ Flame Retardant\u003cbr data-mce-fragment=\"1\"\u003e• UL 1277 TC-ER⁃ Exposed Run Rating\u003cbr data-mce-fragment=\"1\"\u003e• CSA⁃ CSA FT4 Flame Test CSA Cold Impact\/Bend Test (-40C\u003cbr data-mce-fragment=\"1\"\u003e• MSHA⁃ Type MP and Type MP-GC\u003cbr data-mce-fragment=\"1\"\u003e• IEEE 1580⁃ Marine Shipboard Cable Rating\u003cbr data-mce-fragment=\"1\"\u003e• ABS⁃ American Bureau of Shipping Type Approval\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":51644958245233,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/2_8551b734-d358-44a8-9380-2d1f97df0be6.png?v=1759829449"},{"product_id":"prysmian-airguard-mv105-15kv-3c-epr-pvc-133-aluminum-medium-voltage-power-cable","title":"Prysmian Airguard MV105 15KV 3C EPR\/PVC 133% Aluminum Medium Voltage Power Cable","description":"\u003cp\u003e[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Prysmian_Airguard.pdf?v=1666969345\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003ePrysmian Airguard MV105 15KV 3C EPR\/PVC 133% Aluminum Medium Voltage Power Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e• Prysmian’s patented AIRGUARD cable is a direct replacement for continuously corrugated and welded aluminum armored cables (*in Class 1 Div 2 locations) with 5X the impact performance and up to 3X the sidewall bearing pressure limit (at 3000 lbs per rad-ft) This enables longer pulls \u003cspan\u003eThis enables longer pulls than with CCW type cables. \u003c\/span\u003e\u003cbr\u003e• Three conductor cable with stranded or aluminum conductors, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX EPR insulation, thermosetting semiconducting insulation shield, helically applied bare tape shield, cabled with fillers and grounding conductors, overall binder tape, foamed polymeric AIR BAG layer for superior mechanical protection, longitudinally applied aluminum tape, extruded oil and hydrocarbon resistant polymeric DRYLAM layer, and overall sunlight resistant PVC jacket. Suitable for Class I Division 2 locations.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePrysmian MV105 15kV Cable, Airguard 15kV Aluminum Cable, 3C EPR PVC 15kV Cable, Prysmian 15kV 133% insulation, 15kV Aluminum MV105 Cable, Medium Voltage Airguard 15kV, 15kV 3 Conductor EPR Cable, Prysmian 15kV Medium Voltage, MV105 15kV Aluminum Cable, 133% Insulated 15kV Cable\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eClass B Compact concentric strand aluminum alloy 1350 or soft drawn annealed per ASTM.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eHelically applied non-magnetic tape(s) over the insulation shield with a nominal overlap of 25%. A mylar ribbon is longitudinally applied under the tape shield for phase identification - 1C w\/ Red, 1C w\/ Blue, and 1C w\/ Black.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003eExtruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eNatural high dielectric strength EPROTENAX EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eExtruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eGrounding Conductors:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eBare stranded conductor per UL, ICEA, and ASTM.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eAssembly:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePhase identified conductors cabled with fillers and grounding conductors, forming a firm and cylindrical cable core. A binder tape is applied to maintain core symmetry and mechanical stability.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eHigh strength and high crush resistant AIR BAG layer extruded over the core assembly.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eA layer of DRYLAM which consists of a 6mil longitudinally applied aluminum tape and a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eSunlight and moisture resistant polyvinyl chloride (PVC) jacket.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eStandards: \u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e• UL 1072 ⁃ Type MV-105, For CT USE Direct Buried\/Sunlight Resistant\u003cbr\u003e• IEEE ⁃ Flame Retardant\u003cbr\u003e• UL 1277 TC-ER⁃ Exposed Run Rating\u003cbr\u003e• CSA⁃ CSA FT4 Flame Test CSA Cold Impact\/Bend Test (-40C\u003cbr\u003e• MSHA⁃ Type MP and Type MP-GC\u003cbr\u003e• IEEE 1580⁃ Marine Shipboard Cable Rating\u003cbr\u003e• ABS⁃ American Bureau of Shipping Type Approval\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":51644980232561,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/2_a98bc0ca-d2b1-4a30-89b0-4734ce6f166d.png?v=1763007553"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/collections\/MV_Power.png?v=1635519025","url":"https:\/\/nassaunationalcable.com\/collections\/medium-voltage-power-cables.oembed?page=2","provider":"NassauNationalCable","version":"1.0","type":"link"}