{"title":"Marine Cables and Tools","description":null,"products":[{"product_id":"1-2-2000v","title":"1\/2 TYPE W MAGNET CRANE CABLE MARINE CABLE 2000V","description":"\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch2\u003e1\/2 Type W Magnet Crane Cable Marine Cable 2000V\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity For 1\/2 Type W Magnet Crane Cable 2000V: \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e221 Amps\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eType W Magnet Crane Portable Power Cable is used in heavy-duty applications, magnet cranes, drills, scrap yards, foundries,and pumps where flexibility and durability is a must. The electrical cable is resistant to abrasion, tears, cutovers, cut-throughs, and other kinds of a severe mechanical impact. In dry conditions, Type W Magnet Crane Cable is suitable for temperatures between 105° C and -55° C. Type W Magnet Crane Wire has a 2000V rating.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e1\/2 Type W Magnet Crane Portable Power Cable, 1\/2 Type W Magnet Crane Wire, 1\/2 Type W Magnet Crane Marine Cable, 1\/2 Type TC Magnet Crane Cable, 1\/2 Type W Magnet Crane Direct Burial Wire, 1\/2 Type W Magnet Crane Flexible Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eASTM B-3, ASTM B-172, and UL-62 (Conductor)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e UL Listed Type W\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eNEMA WC-58 (Suitable for mining applications)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eICEA S-95-658\/ NEMA WC-70\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eMSHA P-184\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e FT-4 Flame Test\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003ci\u003e\u003cspan style=\"font-weight: 400;\"\u003eConductor:\u003c\/span\u003e\u003c\/i\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eExtra-flexible rope stranding (Class K), soft-drawn uncoated copper; per ASTM B-3, ASTM B-172, and UL-62. Conductors are cabled with non-wicking, nonhygroscopic fillers with an overall binder of rubberized fabric tape\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003ci\u003e\u003cspan style=\"font-weight: 400;\"\u003eInsulation:\u003c\/span\u003e\u003c\/i\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eColor-coded Thermoset (EPDM) insulation per UL-62 and ICEA S-68-516\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003ci\u003e\u003cspan style=\"font-weight: 400;\"\u003eJacket:\u003c\/span\u003e\u003c\/i\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eCPE rubber jacket\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eAWG Size: 1\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eNumber of Conductors: 2\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eStranding: 836\/30\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eNominal Diameter (inches): 1.460\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMin. Bending Diameter (inches): 12.0\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eNet Weight (Lbs\/1000 FT): 1585\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e[\/short]\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMARINE WIRE TYPE W MAGNET CRANE CABLE 105° C TO -55° C\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2000 VOLT\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAPPLICATIONS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe intention of the Magnet Crane wire is built to be able to resist the abusive situations mainly in magnet crane areas of action. These wires resist cuts over, puncture, tearing, abrasion and impact better than standard Type W, due to the rough design and material choice. Magnet Crane Cables are perfect for use in scrap yards, foundries, and other installations where there is a severe risk of metal cut through.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFEATURES AND BENEFITS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExtra-flexible rope stranding (Class K), soft-drawn uncoated copper; per ASTM B-3, ASTM B-172, and UL-62.\u003c\/li\u003e\n\u003cli\u003eGreat flexibility, long flexibility lifespan, reduced copper fatigue and conductor rupture.\u003c\/li\u003e\n\u003cli\u003ePaper separator \/ Easy stripping\u003c\/li\u003e\n\u003cli\u003eColor coded Themoset (EPDM) insulation per UL-62 and ICEA S-68-516\u003c\/li\u003e\n\u003cli\u003eExcellent physical and electrical properties, easy conductor identification, will not melt or deform during emergency overload or short circuit conditions\u003c\/li\u003e\n\u003cli\u003eConductors are cabled with non-wicking, nonhygroscopic fillers with an overall binder of rubberized fabric tape\u003c\/li\u003e\n\u003cli\u003eStrength increased mechanical and impact resistance, and exceptional performance in severe flexing applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eRATINGS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMagnet Crane Cables are rated for constant operation at 105° C to -55° C in all dry situations. Cables are also UL listed (E130231) Type W 2000 volts 90° C with in wet or dry, sunlight resistant, -40° C and are certified CSA (LL36970) Type W, 2000 volt, -55° C FT1. \u003c\/p\u003e\n\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e","brand":"Nassau National cable","offers":[{"title":"Default Title","offer_id":27521905524836,"sku":"NNC4728X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/3724.png?v=1790869332"},{"product_id":"1-0-2-2000v","title":"1\/0-2 Type W Magnet Crane Cable Marine Cable 2000V","description":"\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch2\u003e1-0\/2 Type W Magnet Crane Cable Marine Cable 2000V\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity For 1-0\/2 Type W Magnet Crane Cable 2000V: \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e256 Amps\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eType W Magnet Crane Portable Power Cable is used in heavy-duty applications, magnet cranes, drills, scrap yards, foundries,and pumps where flexibility and durability is a must. The electrical cable is resistant to abrasion, tears, cutovers, cut-throughs, and other kinds of a severe mechanical impact. In dry conditions, Type W Magnet Crane Cable is suitable for temperatures between 105° C and -55° C. Type W Magnet Crane Wire has a 2000V rating.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e1-0\/2 Type W Magnet Crane Portable Power Cable, 1-0\/2 Type W Magnet Crane Wire, 1-0\/2 Type W Magnet Crane Marine Cable, 1-0\/2 Type TC Magnet Crane Cable, \u003cmeta charset=\"utf-8\"\u003e \u003cspan data-mce-fragment=\"1\"\u003e1-0\/2 \u003c\/span\u003eType W Magnet Crane Direct Burial Wire, \u003cmeta charset=\"utf-8\"\u003e \u003cspan data-mce-fragment=\"1\"\u003e1-0\/2 \u003c\/span\u003eType W Magnet Crane Flexible Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eASTM B-3, ASTM B-172, and UL-62 (Conductor)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eUL Listed Type W\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eNEMA WC-58 (Suitable for mining applications)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eICEA S-95-658\/ NEMA WC-70\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eMSHA P-184\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eFT-4 Flame Test\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003ci\u003e\u003cspan style=\"font-weight: 400;\"\u003eConductor:\u003c\/span\u003e\u003c\/i\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eExtra-flexible rope stranding (Class K), soft-drawn uncoated copper; per ASTM B-3, ASTM B-172, and UL-62. Conductors are cabled with non-wicking, nonhygroscopic fillers with an overall binder of rubberized fabric tape\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003ci\u003e\u003cspan style=\"font-weight: 400;\"\u003eInsulation:\u003c\/span\u003e\u003c\/i\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eColor-coded Thermoset (EPDM) insulation per UL-62 and ICEA S-68-516\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003ci\u003e\u003cspan style=\"font-weight: 400;\"\u003eJacket:\u003c\/span\u003e\u003c\/i\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eCPE rubber jacket\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eAWG Size: 1\/0\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eNumber of Conductors: 2\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eStranding: 1045\/30\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eNominal Diameter (inches): 1.608\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMin. Bending Diameter (inches): 13.0\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eNet Weight (Lbs\/1000 FT): 1868\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e[\/short]\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMARINE WIRE TYPE W MAGNET CRANE CABLE 105° C TO -55° C\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2000 VOLT\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAPPLICATIONS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe intention of the Magnet Crane wire is built to be able to resist the abusive situations mainly in magnet crane areas of action. These wires resist cuts over, puncture, tearing, abrasion and impact better than standard Type W, due to the rough design and material choice. Magnet Crane Cables are perfect for use in scrap yards, foundries, and other installations where there is a severe risk of metal cut through.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFEATURES AND BENEFITS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExtra-flexible rope stranding (Class K), soft-drawn uncoated copper; per ASTM B-3, ASTM B-172, and UL-62.\u003c\/li\u003e\n\u003cli\u003eGreat flexibility, long flexibility lifespan, reduced copper fatigue and conductor rupture.\u003c\/li\u003e\n\u003cli\u003ePaper separator \/ Easy stripping\u003c\/li\u003e\n\u003cli\u003eColor coded Themoset (EPDM) insulation per UL-62 and ICEA S-68-516\u003c\/li\u003e\n\u003cli\u003eExcellent physical and electrical properties, easy conductor identification, will not melt or deform during emergency overload or short circuit conditions\u003c\/li\u003e\n\u003cli\u003eConductors are cabled with non-wicking, nonhygroscopic fillers with an overall binder of rubberized fabric tape\u003c\/li\u003e\n\u003cli\u003eStrength increased mechanical and impact resistance, and exceptional performance in severe flexing applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eRATINGS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMagnet Crane Cables are rated for constant operation at 105° C to -55° C in all dry situations. Cables are also UL listed (E130231) Type W 2000 volts 90° C with in wet or dry, sunlight resistant, -40° C and are certified CSA (LL36970) Type W, 2000 volt, -55° C FT1. \u003c\/p\u003e\n\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27521905557604,"sku":"NNC4729X","price":12.71,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/FittingType_18_35a86534-98da-4ce4-98a6-dbc1fb2e6094.jpg?v=1787653071"},{"product_id":"10-shea-single-armor-mar-2000v","title":"10 SHEATHED SINGLE CONDUCTOR ARMORED TYPE P DRILLING RIG MARINE POWER CABLE 2000V","description":"\u003cp\u003e\u003cstrong\u003eFEATURES:\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\n\u003cspan\u003eHigh strand count conductors make this product extremely flexible, \u003c\/span\u003e\u003cspan\u003eeasier to install and more resistant to vibration than Type MC, IEC \u003c\/span\u003e\u003cspan\u003espec or commercial cables.\u003c\/span\u003e\n\u003c\/li\u003e\r\n\u003cli\u003e\n\u003cspan\u003eLower dielectric constant and higher insulation resistance reduces \u003c\/span\u003e\u003cspan\u003eelectrical losses.\u003c\/span\u003e\n\u003c\/li\u003e\r\n\u003cli\u003e\n\u003cspan\u003eExcellent resistance to moisture produces stable electrical properties \u003c\/span\u003e\u003cspan\u003ethroughout the life of the cable.\u003c\/span\u003e\n\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan\u003eIn fire conditions, non chlorinated flame retardant system produces \u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan\u003eless toxic and less corrosive gasses.\u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\n\u003cspan\u003eDual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 \u003c\/span\u003e\u003cspan\u003eType X110.\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\r\n\u003cli\u003e\n\u003cspan\u003eHighest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, \u003c\/span\u003e\u003cspan\u003eTransport Canada 95°C\u003c\/span\u003e\n\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan\u003eSevere cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan\u003eFlame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDesigned and constructed for the demanding environments of offshore drilling and petroleum facilities located throughout the world.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eCONDUCTOR:\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. \u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eARMOR:\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eBasket weave wire armor per IEEE 1580 and UL 1309\/CSA C22.2 No. 245. Bronze standard. Also available on reqeust for Tinned copper.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eSHEATH:\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eA black, artic grade, flame retardant, oil abrasion, chemical and sunlight resistant thermosetting compound meeting UL 1309 \/ CSA c22.2 No. 245 and IEEE 1580  \u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eINSULATION\/JACKET:\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eFlame Retardant Cross-linked Polyolefin, meeting the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eRATINGS \u0026amp; APPROVALS:\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eNVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eTRANSPORT CANADA\u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eDET NORSKE VERITAS (DNV)\u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003eLLOYDE'S REGISTER OF SHIPPIN (LRS)\u003c\/li\u003e\r\n\u003cli\u003eAMERICAN BUREAU OF SHIPPING (ABS)\u003c\/li\u003e\r\n\u003cli\u003eUL LISTED AS MARINE SHIPBOARD CABLE\u003c\/li\u003e\r\n\u003cli\u003eUNITED STATES COAST GUARD  \u003c\/li\u003e\r\n\u003cli\u003eCSA LISTED AS MARINE SHIPBOARD CABLE \u003c\/li\u003e\r\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27521926299748,"sku":"NNC4825X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/two_c_type_p_3_10_7_323a1000-b865-48ef-91f8-ffde2658558d.png?v=1759804869"},{"product_id":"1-shea-single-armor-mar-2000v","title":"1 SHEATHED SINGLE CONDUCTOR ARMORED TYPE P DRILLING RIG MARINE POWER CABLE 2000V","description":"\u003cp\u003e\u003cstrong\u003eFEATURES:\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\n\u003cspan\u003eHigh strand count conductors make this product extremely flexible, \u003c\/span\u003e\u003cspan\u003eeasier to install and more resistant to vibration than Type MC, IEC \u003c\/span\u003e\u003cspan\u003espec or commercial cables.\u003c\/span\u003e\n\u003c\/li\u003e\r\n\u003cli\u003e\n\u003cspan\u003eLower dielectric constant and higher insulation resistance reduces \u003c\/span\u003e\u003cspan\u003eelectrical losses.\u003c\/span\u003e\n\u003c\/li\u003e\r\n\u003cli\u003e\n\u003cspan\u003eExcellent resistance to moisture produces stable electrical properties \u003c\/span\u003e\u003cspan\u003ethroughout the life of the cable.\u003c\/span\u003e\n\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan\u003eIn fire conditions, non chlorinated flame retardant system produces \u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan\u003eless toxic and less corrosive gasses.\u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\n\u003cspan\u003eDual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 \u003c\/span\u003e\u003cspan\u003eType X110.\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\r\n\u003cli\u003e\n\u003cspan\u003eHighest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, \u003c\/span\u003e\u003cspan\u003eTransport Canada 95°C\u003c\/span\u003e\n\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan\u003eSevere cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan\u003eFlame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDesigned and constructed for the demanding environments of offshore drilling and petroleum facilities located throughout the world.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eCONDUCTOR:\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. \u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eARMOR:\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eBasket weave wire armor per IEEE 1580 and UL 1309\/CSA C22.2 No. 245. Bronze standard. Also available on reqeust for Tinned copper.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eSHEATH:\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eA black, artic grade, flame retardant, oil abrasion, chemical and sunlight resistant thermosetting compound meeting UL 1309 \/ CSA c22.2 No. 245 and IEEE 1580  \u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eINSULATION\/JACKET:\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eFlame Retardant Cross-linked Polyolefin, meeting the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eRATINGS \u0026amp; APPROVALS:\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eNVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eTRANSPORT CANADA\u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eDET NORSKE VERITAS (DNV)\u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003eLLOYDE'S REGISTER OF SHIPPIN (LRS)\u003c\/li\u003e\r\n\u003cli\u003eAMERICAN BUREAU OF SHIPPING (ABS)\u003c\/li\u003e\r\n\u003cli\u003eUL LISTED AS MARINE SHIPBOARD CABLE\u003c\/li\u003e\r\n\u003cli\u003eUNITED STATES COAST GUARD  \u003c\/li\u003e\r\n\u003cli\u003eCSA LISTED AS MARINE SHIPBOARD CABLE \u003c\/li\u003e\r\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27521927217252,"sku":"NNC4830X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/two_c_type_p_3_10_7_1f4528cc-910e-4606-a7f2-3484893fced9.png?v=1762459608"},{"product_id":"1-0-shea-single-armor-mar-2000v","title":"1\/0 SHEATHED SINGLE CONDUCTOR ARMORED TYPE P DRILLING RIG MARINE POWER CABLE 2000V","description":"\u003cp\u003e\u003cstrong\u003eFEATURES:\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\n\u003cspan\u003eHigh strand count conductors make this product extremely flexible, \u003c\/span\u003e\u003cspan\u003eeasier to install and more resistant to vibration than Type MC, IEC \u003c\/span\u003e\u003cspan\u003espec or commercial cables.\u003c\/span\u003e\n\u003c\/li\u003e\r\n\u003cli\u003e\n\u003cspan\u003eLower dielectric constant and higher insulation resistance reduces \u003c\/span\u003e\u003cspan\u003eelectrical losses.\u003c\/span\u003e\n\u003c\/li\u003e\r\n\u003cli\u003e\n\u003cspan\u003eExcellent resistance to moisture produces stable electrical properties \u003c\/span\u003e\u003cspan\u003ethroughout the life of the cable.\u003c\/span\u003e\n\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan\u003eIn fire conditions, non chlorinated flame retardant system produces \u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan\u003eless toxic and less corrosive gasses.\u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\n\u003cspan\u003eDual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 \u003c\/span\u003e\u003cspan\u003eType X110.\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\r\n\u003cli\u003e\n\u003cspan\u003eHighest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, \u003c\/span\u003e\u003cspan\u003eTransport Canada 95°C\u003c\/span\u003e\n\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan\u003eSevere cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan\u003eFlame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eDesigned and constructed for the demanding environments of offshore drilling and petroleum facilities located throughout the world.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eCONDUCTOR:\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. \u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eARMOR:\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eBasket weave wire armor per IEEE 1580 and UL 1309\/CSA C22.2 No. 245. Bronze standard. Also available on reqeust for Tinned copper.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eSHEATH:\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eA black, artic grade, flame retardant, oil abrasion, chemical and sunlight resistant thermosetting compound meeting UL 1309 \/ CSA c22.2 No. 245 and IEEE 1580  \u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eINSULATION\/JACKET:\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eFlame Retardant Cross-linked Polyolefin, meeting the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eRATINGS \u0026amp; APPROVALS:\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eNVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eTRANSPORT CANADA\u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eDET NORSKE VERITAS (DNV)\u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003eLLOYDE'S REGISTER OF SHIPPIN (LRS)\u003c\/li\u003e\r\n\u003cli\u003eAMERICAN BUREAU OF SHIPPING (ABS)\u003c\/li\u003e\r\n\u003cli\u003eUL LISTED AS MARINE SHIPBOARD CABLE\u003c\/li\u003e\r\n\u003cli\u003eUNITED STATES COAST GUARD  \u003c\/li\u003e\r\n\u003cli\u003eCSA LISTED AS MARINE SHIPBOARD CABLE \u003c\/li\u003e\r\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27521927315556,"sku":"NNC4831X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/two_c_type_p_3_10_7_64c75027-6fd1-468d-9f93-7d0530af7776.png?v=1762459608"},{"product_id":"1111-shea-single-armor-mar-2000v","title":"1111 SHEATHED SINGLE CONDUCTOR ARMORED TYPE P DRILLING RIG MARINE POWER CABLE 2000V","description":"\u003ctable stat-table=\"\" style=\"width: 521px;\" font-size:=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 411.16px;\"\u003eAWG Size\u003c\/th\u003e\n\u003ctd style=\"width: 97.8403px;\"\u003e1111\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 411.16px;\"\u003eMM2\u003c\/th\u003e\n\u003ctd style=\"width: 97.8403px;\"\u003e562\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 411.16px;\"\u003eNominal Diameter (inches)\u003c\/th\u003e\n\u003ctd style=\"width: 97.8403px;\"\u003e1.954\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 411.16px;\"\u003eNet Weight (Lbs\/1000 FT)\u003c\/th\u003e\n\u003ctd style=\"width: 97.8403px;\"\u003e4484   \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 411.16px;\"\u003eAmpacity\u003c\/th\u003e\n\u003ctd style=\"width: 97.8403px;\"\u003e         \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 411.16px;\"\u003e105ºC\u003c\/th\u003e\n\u003ctd style=\"width: 97.8403px;\"\u003e1098\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 411.16px;\"\u003e100ºC\u003c\/th\u003e\n\u003ctd style=\"width: 97.8403px;\"\u003e1025\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 411.16px;\"\u003e 95ºC\u003c\/th\u003e\n\u003ctd style=\"width: 97.8403px;\"\u003e937\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eFEATURES:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003eHigh strand count conductors make this product extremely flexible, \u003c\/span\u003e\u003cspan\u003eeasier to install and more resistant to vibration than Type MC, IEC \u003c\/span\u003e\u003cspan\u003espec or commercial cables.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eLower dielectric constant and higher insulation resistance reduces \u003c\/span\u003e\u003cspan\u003eelectrical losses.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eExcellent resistance to moisture produces stable electrical properties \u003c\/span\u003e\u003cspan\u003ethroughout the life of the cable.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIn fire conditions, non chlorinated flame retardant system produces \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eless toxic and less corrosive gasses.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eDual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 \u003c\/span\u003e\u003cspan\u003eType X110.\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eHighest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, \u003c\/span\u003e\u003cspan\u003eTransport Canada 95°C\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSevere cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFlame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDesigned and constructed for the demanding environments of offshore drilling and petroleum facilities located throughout the world.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCONDUCTOR:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eARMOR:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBasket weave wire armor per IEEE 1580 and UL 1309\/CSA C22.2 No. 245. Bronze standard. Also available on reqeust for Tinned copper.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSHEATH:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA black, artic grade, flame retardant, oil abrasion, chemical and sunlight resistant thermosetting compound meeting UL 1309 \/ CSA c22.2 No. 245 and IEEE 1580  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eINSULATION\/JACKET:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFlame Retardant Cross-linked Polyolefin, meeting the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRATINGS \u0026amp; APPROVALS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eNVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eTRANSPORT CANADA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eDET NORSKE VERITAS (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eLLOYDE'S REGISTER OF SHIPPIN (LRS)\u003c\/li\u003e\n\u003cli\u003eAMERICAN BUREAU OF SHIPPING (ABS)\u003c\/li\u003e\n\u003cli\u003eUL LISTED AS MARINE SHIPBOARD CABLE\u003c\/li\u003e\n\u003cli\u003eUNITED STATES COAST GUARD  \u003c\/li\u003e\n\u003cli\u003eCSA LISTED AS MARINE SHIPBOARD CABLE \u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27521929642084,"sku":"NNC4845X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/two_c_type_p_3_10_08b23c60-b489-4c14-8966-9e0c4b5d163a.png?v=1762459617"},{"product_id":"10-two-co-mar-1k-600k","title":"10-2 CONDUCTOR ARMORED TYPE P DRILLING RIG MARINE POWER CABLE 600V \/ 1000kV","description":"\u003cp\u003e\u003cb\u003e[short]\u003c\/b\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cb\u003e10-2 Conductor Armored Type P Drilling Rig Marine Power Cable 600v \/ 1000kv\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity For 10-2 Conductor Armored Type P Drilling Rig Marine Power Cable 600V \/ 1000kV\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 53 Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e105ºC, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e49 Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e100ºC, 43 Amps at 90ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eType P Drilling Rig Marine Power Cable is an electrical cable designed for multipurpose use in offshore and onshore drilling and petroleum facilities. Typical applications include power, control, instrumentation, and communication. Type P cables demonstrate excellent capacity in demanding conditions, including extreme cold, heat, vibration, drilling, corrosion, and mechanical stress. The electrical cables are flame-retardant and resistant to moisture. They are armored with a \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003ebasket weave wire armor per IEEE 1580 and UL 1309\/CSA C22.2 No. 245\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e10-2 Type P Rig Cable, 10-2 Type P Cable, 10-2 Type P Drilling Rig and Marine Cable, 10-2 Rig Cable, 10-2 Type P Polyrad Oil Gas XLPO, 10-2 Type P Power Cable, 10-2 Type P Armored, 10-2 Type P Control Cable, 10-2 Shipboard Cable\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Dual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Highest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Severe cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Flame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• NVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Transport Canada\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• DET Norske Veritas (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Llloyde's Register Of Shipping (LRS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• American Bureau Of Shipping (ABS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• UL Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• United States Coast Guard\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• CSA Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003ci\u003e\u003cspan style=\"font-weight: 400;\"\u003eConductor:\u003c\/span\u003e\u003c\/i\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eHigh strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial cables.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003ci\u003e\u003cspan style=\"font-weight: 400;\"\u003eInsulation\/Jacket:\u003c\/span\u003e\u003c\/i\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eFlame Retardant Cross-linked Polyolefin meets the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e• AWG Size: 10\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• MM2: 5.2\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Nominal Diameter (inches): 0.510      \u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Net Weight (FT): 254\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cb\u003e[\/short]\u003c\/b\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e\n\u003cdiv id=\"gtx-trans\" style=\"position: absolute; left: 81px; top: 411.75px;\"\u003e\n\u003cdiv class=\"gtx-trans-icon\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cgdiv\u003e\u003c\/gdiv\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27521930002532,"sku":"NNC4850X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/58_f99aaa0d-47f3-4bea-8d1a-10789132ca74.png?v=1762459622"},{"product_id":"1-0-two-co-mar-1k-600k","title":"1\/0-2 CONDUCTOR ARMORED TYPE P DRILLING RIG MARINE POWER CABLE 600V \/ 1000kV","description":"\u003cp\u003e\u003cb\u003e[short]\u003c\/b\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cb\u003e1\/0-2 Conductor Armored Type P Drilling Rig Marine Power Cable 600v \/ 1000kv\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity For 1\/0-2 Conductor Armored Type P Drilling Rig Marine Power Cable 600V \/ 1000kV\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 213 Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e105ºC, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e199 Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e100ºC, 184 Amps at 90ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eType P Drilling Rig Marine Power Cable is an electrical cable designed for multipurpose use in offshore and onshore drilling and petroleum facilities. Typical applications include power, control, instrumentation, and communication. Type P cables demonstrate excellent capacity in demanding conditions, including extreme cold, heat, vibration, drilling, corrosion, and mechanical stress. The electrical cables are flame-retardant and resistant to moisture. They are armored with a \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003ebasket weave wire armor per IEEE 1580 and UL 1309\/CSA C22.2 No. 245\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e1\/0-2 Type P Rig Cable, 1\/0-2 Type P Cable, 1\/0-2 Type P Drilling Rig and Marine Cable, 1\/0-2 Rig Cable, 1\/0-2 Type P Polyrad Oil Gas XLPO, 1\/0-2 Type P Power Cable, 1\/0-2 Type P Armored, 1\/0-2 Type P Control Cable, 1\/0-2 Shipboard Cable\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Dual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Highest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Severe cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Flame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• NVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Transport Canada\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• DET Norske Veritas (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Llloyde's Register Of Shipping (LRS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• American Bureau Of Shipping (ABS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• UL Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• United States Coast Guard\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• CSA Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003ci\u003e\u003cspan style=\"font-weight: 400;\"\u003eConductor:\u003c\/span\u003e\u003c\/i\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eHigh strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial cables.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003ci\u003e\u003cspan style=\"font-weight: 400;\"\u003eInsulation\/Jacket:\u003c\/span\u003e\u003c\/i\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eFlame Retardant Cross-linked Polyolefin meets the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e• AWG Size: 1\/0\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• MM2: 54\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Nominal Diameter (inches): 1.293    \u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Net Weight (FT): 1397\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e[\/short]\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e\n\u003cdiv id=\"gtx-trans\" style=\"position: absolute; left: 149px; top: 431.083px;\"\u003e\n\u003cdiv class=\"gtx-trans-icon\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cgdiv\u003e\u003c\/gdiv\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27521930297444,"sku":"NNC4854X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/58_dac42724-8b68-4bc5-9509-4ee945269d69.png?v=1762459625"},{"product_id":"10-three-co-p-1k-600k","title":"10\/3 Type P Drilling Rig Marine Power Cable 600V \/ 1000KV","description":"\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch2\u003e10\/3 Type P Drilling Rig Marine Power Cable 600v \/ 1000kv\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity For 10\/3 Type P Drilling Rig Marine Power Cable 600V \/ 1000kV\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 44 Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e105ºC, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e41 Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e100ºC, 36 Amps at 90ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eType P Drilling Rig Marine Power Cable is an electrical cable designed for multipurpose use in offshore and onshore drilling and petroleum facilities. Typical applications include power, control, instrumentation, and communication. Type P cables demonstrate excellent capacity in demanding conditions, including extreme cold, heat, vibration, drilling, corrosion, and mechanical stress. The electrical cables are flame-retardant and resistant to moisture.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e10\/3 Type P Rig Cable, 10\/3 Type P Cable, 10\/3 Type P Drilling Rig and Marine Cable, 10\/3 Rig Cable, 10\/3 Type P Polyrad Oil Gas XLPO.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e• Dual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e• Highest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e• Severe cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e• Flame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e• NVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e• Transport Canada\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e• DET Norske Veritas (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e• Llloyde's Register Of Shipping (LRS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e• American Bureau Of Shipping (ABS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e• UL Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e• United States Coast Guard\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e• CSA Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eConductor:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eHigh strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial cables.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eInsulation\/Jacket:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eFlame Retardant Cross-linked Polyolefin meets the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e• AWG Size: 10 \u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• MM2: 5.2\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Nominal Diameter (inches): 0.488\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eNet Weight (Lbs\/1000 FT): 189 \u003c\/strong\u003e\u003cb\u003e \u003c\/b\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e [\/short]\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFEATURES:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003eHigh strand count conductors make this product extremely flexible, \u003c\/span\u003e\u003cspan\u003eeasier to install and more resistant to vibration than Type MC, IEC \u003c\/span\u003e\u003cspan\u003espec or commercial cables.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eLower dielectric constant and higher insulation resistance reduces \u003c\/span\u003e\u003cspan\u003eelectrical losses.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eExcellent resistance to moisture produces stable electrical properties \u003c\/span\u003e\u003cspan\u003ethroughout the life of the cable.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIn fire conditions, non chlorinated flame retardant system produces. \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLess toxic and less corrosive gasses.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eDual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 \u003c\/span\u003e\u003cspan\u003eType X110.\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eHighest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, \u003c\/span\u003e\u003cspan\u003eTransport Canada 95°C\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSevere cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFlame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor uses all over the world it is designed and constructed for the demanding environments of offshore drilling and petroleum facilities. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCONDUCTOR:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eINSULATION\/JACKET: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFlame Retardant Cross-linked Polyolefin, meeting the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRATINGS \u0026amp; APPROVALS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eNVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eTRANSPORT CANADA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eDET NORSKE VERITAS (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eLLOYDE'S REGISTER OF SHIPPIN (LRS)\u003c\/li\u003e\n\u003cli\u003eAMERICAN BUREAU OF SHIPPING (ABS)\u003c\/li\u003e\n\u003cli\u003eUL LISTED AS MARINE SHIPBOARD CABLE\u003c\/li\u003e\n\u003cli\u003eUNITED STATES COAST GUARD  \u003c\/li\u003e\n\u003cli\u003eCSA LISTED AS MARINE SHIPBOARD CABLE \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Nassau National cable","offers":[{"title":"Default Title","offer_id":27521936392292,"sku":"NNC4876X","price":4.58,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/59_f3f94fe6-be38-48ad-82fb-fc6ca829d963.png?v=1762459633"},{"product_id":"1-three-co-p-1k-600k","title":"1\/3 TYPE P DRILLING RIG MARINE POWER CABLE 600V \/ 1000kV","description":"\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch2\u003e1\/3 Type P Drilling Rig Marine Power Cable 600v \/ 1000kv\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity For 1\/3 Type P Drilling Rig Marine Power Cable 600V \/ 1000kV\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 153 Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e105ºC, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e143 Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e100ºC, 235 Amps at 90ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eType P Drilling Rig Marine Power Cable is an electrical cable designed for multipurpose use in offshore and onshore drilling and petroleum facilities. Typical applications include power, control, instrumentation, and communication. Type P cables demonstrate excellent capacity in demanding conditions, including extreme cold, heat, vibration, drilling, corrosion, and mechanical stress. The electrical cables are flame-retardant and resistant to moisture.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e1\/3 Type P Rig Cable, 1\/3 Type P Cable, 1\/3 Type P Drilling Rig and Marine Cable, 1\/3 Rig Cable, 1\/3 Type P Polyrad Oil Gas XLPO, 1\/3 Type P Power Cable, 1\/3 Shipboard Cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e• Dual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e• Highest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e• Severe cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e• Flame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e• NVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e• Transport Canada\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e• DET Norske Veritas (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e• Llloyde's Register Of Shipping (LRS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e• American Bureau Of Shipping (ABS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e• UL Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e• United States Coast Guard\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e• CSA Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\n\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eConductor:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eHigh strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial cables.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eInsulation\/Jacket:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eFlame Retardant Cross-linked Polyolefin meets the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e• AWG Size: 1   \u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• MM2: 43\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Nominal Diameter (inches): 1.256\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Net Weight (Lbs\/1000 FT): 1458\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFEATURES:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003eHigh strand count conductors make this product extremely flexible, \u003c\/span\u003e\u003cspan\u003eeasier to install and more resistant to vibration than Type MC, IEC \u003c\/span\u003e\u003cspan\u003espec or commercial cables.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eLower dielectric constant and higher insulation resistance reduces \u003c\/span\u003e\u003cspan\u003eelectrical losses.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eExcellent resistance to moisture produces stable electrical properties \u003c\/span\u003e\u003cspan\u003ethroughout the life of the cable.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIn fire conditions, non chlorinated flame retardant system produces. \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLess toxic and less corrosive gasses.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eDual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 \u003c\/span\u003e\u003cspan\u003eType X110.\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eHighest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, \u003c\/span\u003e\u003cspan\u003eTransport Canada 95°C\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSevere cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFlame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor uses all over the world it is designed and constructed for the demanding environments of offshore drilling and petroleum facilities. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCONDUCTOR:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eINSULATION\/JACKET: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFlame Retardant Cross-linked Polyolefin, meeting the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRATINGS \u0026amp; APPROVALS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eNVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eTRANSPORT CANADA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eDET NORSKE VERITAS (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eLLOYDE'S REGISTER OF SHIPPIN (LRS)\u003c\/li\u003e\n\u003cli\u003eAMERICAN BUREAU OF SHIPPING (ABS)\u003c\/li\u003e\n\u003cli\u003eUL LISTED AS MARINE SHIPBOARD CABLE\u003c\/li\u003e\n\u003cli\u003eUNITED STATES COAST GUARD  \u003c\/li\u003e\n\u003cli\u003eCSA LISTED AS MARINE SHIPBOARD CABLE \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cgdiv\u003e\u003c\/gdiv\u003e\u003ciframe class=\"ginger-extension-definitionpopup\" style=\"display: none;\"\u003e\u003c\/iframe\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e\n\u003cdiv id=\"gtx-trans\" style=\"position: absolute; left: -17px; top: 865.833px;\"\u003e\n\u003cdiv class=\"gtx-trans-icon\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cgdiv\u003e\u003c\/gdiv\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27521939046500,"sku":"NNC4880X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/59_2aa22314-ad66-49e0-9103-d23da26387ae.png?v=1762459636"},{"product_id":"1-0-three-co-p-1k-600k","title":"1\/0-3 TYPE P DRILLING RIG MARINE POWER CABLE 600V \/ 1000kV","description":"\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch2\u003e1\/0-3 Type P Drilling Rig Marine Power Cable 600v \/ 1000kv\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity For 1\/0-3 Type P Drilling Rig Marine Power Cable 600V \/ 1000kV\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 176 Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e105ºC, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e164 Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e100ºC, 152 Amps at 90ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eType P Drilling Rig Marine Power Cable is an electrical cable designed for multipurpose use in offshore and onshore drilling and petroleum facilities. Typical applications include power, control, instrumentation, and communication. Type P cables demonstrate excellent capacity in demanding conditions, including extreme cold, heat, vibration, drilling, corrosion, and mechanical stress. The electrical cables are flame-retardant and resistant to moisture.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e1\/0-3 Type P Rig Cable, 1\/0-3 Type P Cable, 1\/0-3 Type P Drilling Rig and Marine Cable, 1\/0-3 Rig Cable, 1\/0-3 Type P Polyrad Oil Gas XLPO, 1\/0-3 Type P Power Cable, 1\/0-3 Shipboard Cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Dual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Highest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Severe cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Flame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• NVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Transport Canada\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• DET Norske Veritas (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Llloyde's Register Of Shipping (LRS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• American Bureau Of Shipping (ABS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• UL Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• United States Coast Guard\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• CSA Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eConductor:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eHigh strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial cables.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eInsulation\/Jacket:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eFlame Retardant Cross-linked Polyolefin meets the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e• AWG Size: 1\/0   \u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• MM2: 54\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Nominal Diameter (inches): 1.376\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Net Weight (Lbs\/1000 FT): 1781 \u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFEATURES:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003eHigh strand count conductors make this product extremely flexible, \u003c\/span\u003e\u003cspan\u003eeasier to install and more resistant to vibration than Type MC, IEC \u003c\/span\u003e\u003cspan\u003espec or commercial cables.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eLower dielectric constant and higher insulation resistance reduces \u003c\/span\u003e\u003cspan\u003eelectrical losses.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eExcellent resistance to moisture produces stable electrical properties \u003c\/span\u003e\u003cspan\u003ethroughout the life of the cable.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIn fire conditions, non chlorinated flame retardant system produces. \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLess toxic and less corrosive gasses.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eDual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 \u003c\/span\u003e\u003cspan\u003eType X110.\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eHighest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, \u003c\/span\u003e\u003cspan\u003eTransport Canada 95°C\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSevere cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFlame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor uses all over the world it is designed and constructed for the demanding environments of offshore drilling and petroleum facilities. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCONDUCTOR:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eINSULATION\/JACKET: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFlame Retardant Cross-linked Polyolefin, meeting the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRATINGS \u0026amp; APPROVALS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eNVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eTRANSPORT CANADA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eDET NORSKE VERITAS (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eLLOYDE'S REGISTER OF SHIPPIN (LRS)\u003c\/li\u003e\n\u003cli\u003eAMERICAN BUREAU OF SHIPPING (ABS)\u003c\/li\u003e\n\u003cli\u003eUL LISTED AS MARINE SHIPBOARD CABLE\u003c\/li\u003e\n\u003cli\u003eUNITED STATES COAST GUARD  \u003c\/li\u003e\n\u003cli\u003eCSA LISTED AS MARINE SHIPBOARD CABLE \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e\n\u003cdiv id=\"gtx-trans\" style=\"position: absolute; left: -17px; top: 913.5px;\"\u003e\n\u003cdiv class=\"gtx-trans-icon\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cgdiv\u003e\u003c\/gdiv\u003e","brand":"Nassau National cable","offers":[{"title":"Default Title","offer_id":27521939177572,"sku":"NNC4882X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/59_d995a51d-fe2c-4e99-b460-4739021aaec3.png?v=1762459637"},{"product_id":"10-3-three-co-p-1k-600k","title":"10\/3 ARMORED TYPE P DRILLING RIG MARINE POWER CABLE 600V \/ 1000kV","description":"\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch2\u003e10\/3 Armored Type P Drilling Rig Marine Power Cable 600v \/ 1000kv\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity For 10-3 Armored Type P Drilling Rig Marine Power Cable 600V \/ 1000kV \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 44 Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e105ºC, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e41 Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e100ºC, 36 Amps at 90ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eType P Drilling Rig Marine Power Cable is an electrical cable designed for multipurpose use in offshore and onshore drilling and petroleum facilities. Typical applications include power, control, instrumentation, and communication. Type P cables demonstrate excellent capacity in demanding conditions, including extreme cold, heat, vibration, drilling, corrosion, and mechanical stress. The electrical cables are flame-retardant and resistant to moisture. They are armored with a \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003ebasket weave wire armor per IEEE 1580 and UL 1309\/CSA C22.2 No. 245\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e10\/3 Type P Rig Cable, 10\/3 Type P Cable, 10\/3 Type P Drilling Rig and Marine Cable, 10\/3 Rig Cable, 10\/3 Type P Polyrad Oil Gas XLPO, 10\/3 Type P Power Cable, 10\/3 Type P Armored, 10\/3 Shipboard Cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Dual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Highest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Severe cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Flame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• NVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Transport Canada\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• DET Norske Veritas (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Llloyde's Register Of Shipping (LRS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• American Bureau Of Shipping (ABS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• UL Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• United States Coast Guard\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• CSA Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eConductor:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eHigh strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial cables.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eInsulation\/Jacket:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eFlame Retardant Cross-linked Polyolefin meets the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e• AWG Size: 10  \u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• MM2: 5.2  \u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Nominal Diameter (inches): 0.538\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Net Weight (Lbs\/1000 FT): 281  \u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e[\/short]\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFEATURES:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003eHigh strand count conductors make this product extremely flexible, \u003c\/span\u003e\u003cspan\u003eeasier to install and more resistant to vibration than Type MC, IEC \u003c\/span\u003e\u003cspan\u003espec or commercial cables.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eLower dielectric constant and higher insulation resistance reduces \u003c\/span\u003e\u003cspan\u003eelectrical losses.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eExcellent resistance to moisture produces stable electrical properties \u003c\/span\u003e\u003cspan\u003ethroughout the life of the cable.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIn fire conditions, non chlorinated flame retardant system produces. \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLess toxic and less corrosive gasses.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eDual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 \u003c\/span\u003e\u003cspan\u003eType X110.\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eHighest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, \u003c\/span\u003e\u003cspan\u003eTransport Canada 95°C\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSevere cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFlame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor uses all over the world it is designed and constructed for the demanding environments of offshore drilling and petroleum facilities. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCONDUCTOR:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eARMOR: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBasket weave wire armor per IEEE 1580 and UL 1309\/CSA C22.2 No. 245. Bronze standard. Tinned copper available by request.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eINSULATION\/JACKET: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFlame Retardant Cross-linked Polyolefin, meeting the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRATINGS \u0026amp; APPROVALS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eNVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eTRANSPORT CANADA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eDET NORSKE VERITAS (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eLLOYDE'S REGISTER OF SHIPPIN (LRS)\u003c\/li\u003e\n\u003cli\u003eAMERICAN BUREAU OF SHIPPING (ABS)\u003c\/li\u003e\n\u003cli\u003eUL LISTED AS MARINE SHIPBOARD CABLE\u003c\/li\u003e\n\u003cli\u003eUNITED STATES COAST GUARD  \u003c\/li\u003e\n\u003cli\u003eCSA LISTED AS MARINE SHIPBOARD CABLE \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e\n\u003cdiv style=\"position: absolute; left: -13px; top: 885.167px;\" id=\"gtx-trans\"\u003e\n\u003cdiv class=\"gtx-trans-icon\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cgdiv\u003e\u003c\/gdiv\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27521940488292,"sku":"NNC4897X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/three_c_type_p_armored_db63f715-7879-427e-aeea-b3d1375b83fc.png?v=1762459652"},{"product_id":"1-0-3-three-co-p-1k-600k","title":"1\/0-3 ARMORED TYPE P DRILLING RIG MARINE POWER CABLE 600V \/ 1000kV","description":"\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch2\u003e1\/0-3 Armored Type P Drilling Rig Marine Power Cable 600v \/ 1000kv\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity For 1\/0-3 Armored Type P Drilling Rig Marine Power Cable 600V \/ 1000kV \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 176 Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e105ºC, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e164  Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e100ºC, 152 Amps at 90ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eType P Drilling Rig Marine Power Cable is an electrical cable designed for multipurpose use in offshore and onshore drilling and petroleum facilities. Typical applications include power, control, instrumentation, and communication. Type P cables demonstrate excellent capacity in demanding conditions, including extreme cold, heat, vibration, drilling, corrosion, and mechanical stress. The electrical\u003cbr data-mce-fragment=\"1\"\u003ecables are flame-retardant and resistant to moisture. They are armored with a \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003ebasket weave wire armor per IEEE 1580 and UL 1309\/CSA C22.2 No. 245\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003e1\/0-3 Type P Rig Cable, 1\/0-3 Type P Cable, 1\/0-3 Type P Drilling Rig and Marine Cable, 1\/0-3 Rig Cable, 1\/0-3 Type P Polyrad Oil Gas XLPO, 1\/0-3 Type P Power Cable, 1\/0-3 Type P Armored, 1\/0-3 Shipboard Cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Dual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Highest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Severe cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Flame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• NVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Transport Canada\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• DET Norske Veritas (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Llloyde's Register Of Shipping (LRS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• American Bureau Of Shipping (ABS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• UL Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• United States Coast Guard\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• CSA Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eConductor:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eHigh strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial cables.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eInsulation\/Jacket:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eFlame Retardant Cross-linked Polyolefin meets the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e• AWG Size: 1\/0   \u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• MM2: 54\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Nominal Diameter (inches): 1.376\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eNet Weight (Lbs\/1000 FT): \u003c\/strong\u003e\u003cb\u003e1781  \u003c\/b\u003e\u003cb\u003e \u003c\/b\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFEATURES:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003eHigh strand count conductors make this product extremely flexible, \u003c\/span\u003e\u003cspan\u003eeasier to install and more resistant to vibration than Type MC, IEC \u003c\/span\u003e\u003cspan\u003espec or commercial cables.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eLower dielectric constant and higher insulation resistance reduces \u003c\/span\u003e\u003cspan\u003eelectrical losses.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eExcellent resistance to moisture produces stable electrical properties \u003c\/span\u003e\u003cspan\u003ethroughout the life of the cable.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIn fire conditions, non chlorinated flame retardant system produces. \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLess toxic and less corrosive gasses.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eDual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 \u003c\/span\u003e\u003cspan\u003eType X110.\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eHighest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, \u003c\/span\u003e\u003cspan\u003eTransport Canada 95°C\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSevere cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFlame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor uses all over the world it is designed and constructed for the demanding environments of offshore drilling and petroleum facilities. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCONDUCTOR:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eARMOR: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBasket weave wire armor per IEEE 1580 and UL 1309\/CSA C22.2 No. 245. Bronze standard. Tinned copper available by request.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eINSULATION\/JACKET: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFlame Retardant Cross-linked Polyolefin, meeting the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRATINGS \u0026amp; APPROVALS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eNVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eTRANSPORT CANADA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eDET NORSKE VERITAS (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eLLOYDE'S REGISTER OF SHIPPIN (LRS)\u003c\/li\u003e\n\u003cli\u003eAMERICAN BUREAU OF SHIPPING (ABS)\u003c\/li\u003e\n\u003cli\u003eUL LISTED AS MARINE SHIPBOARD CABLE\u003c\/li\u003e\n\u003cli\u003eUNITED STATES COAST GUARD  \u003c\/li\u003e\n\u003cli\u003eCSA LISTED AS MARINE SHIPBOARD CABLE \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e\n\u003cdiv id=\"gtx-trans\" style=\"position: absolute; left: -6px; top: 779.833px;\"\u003e\n\u003cdiv class=\"gtx-trans-icon\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cgdiv\u003e\u003c\/gdiv\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27521941766244,"sku":"NNC4903X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/three_c_type_p_armored_d1d37cb8-af51-4485-824e-7f4ce2b1596e.png?v=1759804878"},{"product_id":"10-three-co-shea-armored-p-1k-600k","title":"10\/3 Armored \u0026 Sheathed Type P Drilling Rig Marine Power Cable 600V \/ 1000KV","description":"\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch2\u003e10\/3 Armored \u0026amp; Sheathed Type P Drilling Rig Marine Power Cable 600v \/1000kv\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity For 10\/3 Armored \u0026amp; Sheathed Type P Drilling Rig Marine Power Cable 600V \/ 1000kV \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 44 Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e105ºC, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e41 Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e100ºC, 36 Amps at 90ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e10\/3 Armored \u0026amp; Sheathed Type P Rig Cable, 10\/3 Armored \u0026amp; Sheathed Type P Cable, 10\/3 Armored \u0026amp; Sheathed Type P Drilling Rig and Marine Cable, 10\/3 Armored \u0026amp; Sheathed Rig Cable, 10\/3 Armored \u0026amp; Sheathed Type P Polyrad Oil Gas XLPO, \u003cmeta charset=\"utf-8\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e10\/3 \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eType P Power Cable, \u003cmeta charset=\"utf-8\"\u003e \u003cspan data-mce-fragment=\"1\"\u003e10\/3 \u003c\/span\u003eType P Armored Sheathed\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eType P Drilling Rig Marine Power Cable is an electrical cable designed for multipurpose use in offshore and onshore drilling and petroleum facilities. Typical applications include power, control, instrumentation, and communication. Type P cables demonstrate excellent capacity in demanding conditions, including extreme cold, heat, vibration, drilling, corrosion, and mechanical stress. The electrical\u003cbr data-mce-fragment=\"1\"\u003ecables are flame-retardant and resistant to moisture. It is armored with a \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003ebasket weave wire armor per IEEE 1580 and UL 1309\/CSA C22.2 No. 245, and sheathed with a black, arctic grade, flame retardant, oil abrasion, chemical and sunlight resistant thermosetting compound meeting UL 1309 \/ CSA c22.2 No. 245 and IEEE 1580. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Dual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Highest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Severe cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Flame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• NVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Transport Canada\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• DET Norske Veritas (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Llloyde's Register Of Shipping (LRS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• American Bureau Of Shipping (ABS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• UL Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• United States Coast Guard\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• CSA Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003ci\u003e\u003cspan style=\"font-weight: 400;\"\u003eConductor:\u003c\/span\u003e\u003c\/i\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eHigh strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial cables.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003ci\u003e\u003cspan style=\"font-weight: 400;\"\u003eInsulation\/Jacket:\u003c\/span\u003e\u003c\/i\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eFlame Retardant Cross-linked Polyolefin meets the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e• AWG Size: 10\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• MM2: 5.2\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Nominal Diameter (inches): 0.669\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Net Weight (Lbs\/1000 FT): 352\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e[\/short]\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFEATURES:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003eHigh strand count conductors make this product extremely flexible, \u003c\/span\u003e\u003cspan\u003eeasier to install and more resistant to vibration than Type MC, IEC \u003c\/span\u003e\u003cspan\u003espec or commercial cables.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eLower dielectric constant and higher insulation resistance reduces \u003c\/span\u003e\u003cspan\u003eelectrical losses.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eExcellent resistance to moisture produces stable electrical properties \u003c\/span\u003e\u003cspan\u003ethroughout the life of the cable.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIn fire conditions, non chlorinated flame retardant system produces. \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLess toxic and less corrosive gasses.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eDual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 \u003c\/span\u003e\u003cspan\u003eType X110.\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eHighest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, \u003c\/span\u003e\u003cspan\u003eTransport Canada 95°C\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSevere cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFlame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor uses all over the world it is designed and constructed for the demanding environments of offshore drilling and petroleum facilities. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCONDUCTOR:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eARMOR: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBasket weave wire armor per IEEE 1580 and UL 1309\/CSA C22.2 No. 245. Bronze standard. Tinned copper available by request.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSHEATH: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA black, arctic grade, flame retardant, oil abrasion, chemical and sunlight resistant thermosetting compound meeting UL 1309\/CSA C22.2 No. 245 and IEEE 1580.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eINSULATION\/JACKET: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFlame Retardant Cross-linked Polyolefin, meeting the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRATINGS \u0026amp; APPROVALS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eNVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eTRANSPORT CANADA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eDET NORSKE VERITAS (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eLLOYDE'S REGISTER OF SHIPPIN (LRS)\u003c\/li\u003e\n\u003cli\u003eAMERICAN BUREAU OF SHIPPING (ABS)\u003c\/li\u003e\n\u003cli\u003eUL LISTED AS MARINE SHIPBOARD CABLE\u003c\/li\u003e\n\u003cli\u003eUNITED STATES COAST GUARD  \u003c\/li\u003e\n\u003cli\u003eCSA LISTED AS MARINE SHIPBOARD CABLE \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27521943470180,"sku":"NNC4912X","price":13.62,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/59_4271a06c-ee30-4232-b67a-554ba32c5b3e.png?v=1762459662"},{"product_id":"1-three-co-shea-armored-p-1k-600k","title":"1\/3 Armored \u0026 Sheathed Type P Drilling Rig Marine Power Cable 600V \/ 1000Kv","description":"\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch2\u003e1\/3 Armored \u0026amp; Sheathed Type P Drilling Rig Marine Power Cable 600V \/ 1000kV\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity For 1\/3 Armored \u0026amp; Sheathed Type P Drilling Rig Marine Power Cable 600V \/ 1000kV \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 153 Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e105ºC, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e143 Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e100ºC, 131 Amps at 90ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eType P Drilling Rig Marine Power Cable is an electrical cable designed for multipurpose use in offshore and onshore drilling and petroleum facilities. Typical applications include power, control, instrumentation, and communication. Type P cables demonstrate excellent capacity in demanding conditions, including extreme cold, heat, vibration, drilling, corrosion, and mechanical stress. The electrical\u003cbr data-mce-fragment=\"1\"\u003ecables are flame-retardant and resistant to moisture. It is armored with a \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003ebasket weave wire armor per IEEE 1580 and UL 1309\/CSA C22.2 No. 245, and sheathed with a black, arctic grade, flame retardant, oil abrasion, chemical and sunlight resistant thermosetting compound meeting UL 1309 \/ CSA c22.2 No. 245 and IEEE 1580. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1\/3 Armored \u0026amp; Sheathed Type P Rig Cable, 1\/3 Armored \u0026amp; Sheathed Type P Cable, 1\/3 Armored \u0026amp; Sheathed Type P Drilling Rig and Marine Cable, 1\/3 Armored \u0026amp; Sheathed Rig Cable, 1\/3 Armored \u0026amp; Sheathed Type P Polyrad Oil Gas XLPO, \u003cmeta charset=\"utf-8\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e1\/3 \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003eType P Power Cable, \u003cmeta charset=\"utf-8\"\u003e \u003cspan data-mce-fragment=\"1\"\u003e1\/3 \u003c\/span\u003eType P Armored Sheathed\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Dual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Highest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Severe cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Flame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• NVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Transport Canada\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• DET Norske Veritas (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Llloyde's Register Of Shipping (LRS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• American Bureau Of Shipping (ABS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• UL Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• United States Coast Guard\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• CSA Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003ci\u003e\u003cspan style=\"font-weight: 400;\"\u003eConductor:\u003c\/span\u003e\u003c\/i\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eHigh strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial cables.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003ci\u003e\u003cspan style=\"font-weight: 400;\"\u003eInsulation\/Jacket:\u003c\/span\u003e\u003c\/i\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eFlame Retardant Cross-linked Polyolefin meets the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e• AWG Size: 1\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• MM2: 43\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Nominal Diameter (inches): 1.431\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Net Weight (Lbs\/1000 FT): 1675\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e[\/short]\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFEATURES:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003eHigh strand count conductors make this product extremely flexible, \u003c\/span\u003e\u003cspan\u003eeasier to install and more resistant to vibration than Type MC, IEC \u003c\/span\u003e\u003cspan\u003espec or commercial cables.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eLower dielectric constant and higher insulation resistance reduces \u003c\/span\u003e\u003cspan\u003eelectrical losses.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eExcellent resistance to moisture produces stable electrical properties \u003c\/span\u003e\u003cspan\u003ethroughout the life of the cable.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIn fire conditions, non chlorinated flame retardant system produces. \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLess toxic and less corrosive gasses.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eDual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 \u003c\/span\u003e\u003cspan\u003eType X110.\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eHighest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, \u003c\/span\u003e\u003cspan\u003eTransport Canada 95°C\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSevere cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFlame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor uses all over the world it is designed and constructed for the demanding environments of offshore drilling and petroleum facilities. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCONDUCTOR:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eARMOR: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBasket weave wire armor per IEEE 1580 and UL 1309\/CSA C22.2 No. 245. Bronze standard. Tinned copper available by request.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSHEATH: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA black, arctic grade, flame retardant, oil abrasion, chemical and sunlight resistant thermosetting compound meeting UL 1309\/CSA C22.2 No. 245 and IEEE 1580.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eINSULATION\/JACKET: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFlame Retardant Cross-linked Polyolefin, meeting the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRATINGS \u0026amp; APPROVALS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eNVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eTRANSPORT CANADA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eDET NORSKE VERITAS (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eLLOYDE'S REGISTER OF SHIPPIN (LRS)\u003c\/li\u003e\n\u003cli\u003eAMERICAN BUREAU OF SHIPPING (ABS)\u003c\/li\u003e\n\u003cli\u003eUL LISTED AS MARINE SHIPBOARD CABLE\u003c\/li\u003e\n\u003cli\u003eUNITED STATES COAST GUARD  \u003c\/li\u003e\n\u003cli\u003eCSA LISTED AS MARINE SHIPBOARD CABLE \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27521944060004,"sku":"NNC4919X","price":26.48,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/59_f78e784a-090c-4076-b35e-f5398760e7bc.png?v=1762459667"},{"product_id":"1-0-three-co-shea-armored-p-1k-600k","title":"1\/0-3 Armored \u0026 Sheathed Type P Drilling Rig Marine Power Cable 600V \/ 1000Kv","description":"\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch2\u003e1\/0-3 Armored \u0026amp; Sheathed Type P Drilling Rig Marine Power Cable 600v \/1000kv\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity For 1\/0-3 Armored \u0026amp; Sheathed Type P Drilling Rig Marine Power Cable 600V \/ 1000kV \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 176 Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e105ºC, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e164 Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e100ºC, 152 Amps at 90ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eType P Drilling Rig Marine Power Cable is an electrical cable designed for multipurpose use in offshore and onshore drilling and petroleum facilities. Typical applications include power, control, instrumentation, and communication. Type P cables demonstrate excellent capacity in demanding conditions, including extreme cold, heat, vibration, drilling, corrosion, and mechanical stress. The electrical cables are flame-retardant and resistant to moisture. It is armored with a \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003ebasket weave wire armor per IEEE 1580 and UL 1309\/CSA C22.2 No. 245, and sheathed with a black, arctic grade, flame retardant, oil abrasion, chemical and sunlight resistant thermosetting compound meeting UL 1309 \/ CSA c22.2 No. 245 and IEEE 1580. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1\/0-3 Armored \u0026amp; Sheathed Type P Rig Cable, 1\/0-3 Armored \u0026amp; Sheathed Type P Cable, 1\/0-3 Armored \u0026amp; Sheathed Type P Drilling Rig and Marine Cable, 1\/0-3 Armored \u0026amp; Sheathed Rig Cable, 1\/0-3 Armored \u0026amp; Sheathed Type P Polyrad Oil Gas XLPO, \u003cmeta charset=\"utf-8\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e1\/0-3 \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\" data-mce-style=\"font-weight: 400;\"\u003eType P Power Cable, \u003cmeta charset=\"utf-8\"\u003e \u003cspan data-mce-fragment=\"1\"\u003e1\/0-3 \u003c\/span\u003eType P Armored Sheathed\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Dual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Highest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Severe cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Flame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• NVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Transport Canada\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• DET Norske Veritas (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Llloyde's Register Of Shipping (LRS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• American Bureau Of Shipping (ABS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• UL Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• United States Coast Guard\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• CSA Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003ci\u003e\u003cspan style=\"font-weight: 400;\"\u003eConductor:\u003c\/span\u003e\u003c\/i\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eHigh strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial cables.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003ci\u003e\u003cspan style=\"font-weight: 400;\"\u003eInsulation\/Jacket:\u003c\/span\u003e\u003c\/i\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eFlame Retardant Cross-linked Polyolefin meets the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e• AWG Size :1\/0\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• MM2: 54\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Nominal Diameter (inches): 1.550\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Net Weight (Lbs\/1000 FT): 2015\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e[\/short]\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFEATURES:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003eHigh strand count conductors make this product extremely flexible, \u003c\/span\u003e\u003cspan\u003eeasier to install and more resistant to vibration than Type MC, IEC \u003c\/span\u003e\u003cspan\u003espec or commercial cables.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eLower dielectric constant and higher insulation resistance reduces \u003c\/span\u003e\u003cspan\u003eelectrical losses.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eExcellent resistance to moisture produces stable electrical properties \u003c\/span\u003e\u003cspan\u003ethroughout the life of the cable.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIn fire conditions, non chlorinated flame retardant system produces. \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLess toxic and less corrosive gasses.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eDual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 \u003c\/span\u003e\u003cspan\u003eType X110.\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eHighest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, \u003c\/span\u003e\u003cspan\u003eTransport Canada 95°C\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSevere cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFlame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor uses all over the world it is designed and constructed for the demanding environments of offshore drilling and petroleum facilities. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCONDUCTOR:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eARMOR: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBasket weave wire armor per IEEE 1580 and UL 1309\/CSA C22.2 No. 245. Bronze standard. Tinned copper available by request.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSHEATH: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA black, arctic grade, flame retardant, oil abrasion, chemical and sunlight resistant thermosetting compound meeting UL 1309\/CSA C22.2 No. 245 and IEEE 1580.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eINSULATION\/JACKET: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFlame Retardant Cross-linked Polyolefin, meeting the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRATINGS \u0026amp; APPROVALS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eNVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eTRANSPORT CANADA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eDET NORSKE VERITAS (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eLLOYDE'S REGISTER OF SHIPPIN (LRS)\u003c\/li\u003e\n\u003cli\u003eAMERICAN BUREAU OF SHIPPING (ABS)\u003c\/li\u003e\n\u003cli\u003eUL LISTED AS MARINE SHIPBOARD CABLE\u003c\/li\u003e\n\u003cli\u003eUNITED STATES COAST GUARD  \u003c\/li\u003e\n\u003cli\u003eCSA LISTED AS MARINE SHIPBOARD CABLE \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27521944158308,"sku":"NNC4920X","price":26.91,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/59_a9774e2b-4666-48dc-a02e-3cc8d225c43b.png?v=1762459667"},{"product_id":"10-four-con-p-1k-600k","title":"10\/4 Unarmored Type P Drilling Rig Marine Power Cable 600V \/ 1000KV","description":"\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch2\u003e10\/4 Unarmored Type P Drilling Rig Marine Power Cable 600v \/ 1000kv\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity For 10\/4 Unarmored Type P Drilling Rig Marine Power Cable 600V \/ 1000kV \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 44 Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e105ºC, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e41 Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e100ºC, 36 Amps at 90ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eType P Drilling Rig Marine Power Cable is an electrical cable designed for multipurpose use in offshore and onshore drilling and petroleum facilities. Typical applications include power, control, instrumentation, and communication. Type P cables demonstrate excellent capacity in demanding conditions, including extreme cold, heat, vibration, drilling, corrosion, and mechanical stress. The electrical cables are flame-retardant and resistant to moisture. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e10\/4 Unarmored Type P Rig Cable, 10\/4 Unarmored Type P Cable, 10\/4 Unarmored  Type P Drilling Rig and Marine Cable, 10\/4 Unarmored Type Rig Cable, 10\/4 Unarmored Type P Polyrad Oil Gas XLPO\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Dual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Highest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Severe cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Flame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• NVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Transport Canada\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• DET Norske Veritas (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Llloyde's Register Of Shipping (LRS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• American Bureau Of Shipping (ABS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• UL Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• United States Coast Guard\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• CSA Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eConductor:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eHigh strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial cables.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eInsulation\/Jacket:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eFlame Retardant Cross-linked Polyolefin meets the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e• AWG Size: 10\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• MM2: 5.2\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Nominal Diameter (inches): 0.553\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Net Weight (Lbs\/1000 FT): 243\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e[\/short]\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFEATURES:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003eHigh strand count conductors make this product extremely flexible, \u003c\/span\u003e\u003cspan\u003eeasier to install and more resistant to vibration than Type MC, IEC \u003c\/span\u003e\u003cspan\u003espec or commercial cables.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eLower dielectric constant and higher insulation resistance reduces \u003c\/span\u003e\u003cspan\u003eelectrical losses.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eExcellent resistance to moisture produces stable electrical properties \u003c\/span\u003e\u003cspan\u003ethroughout the life of the cable.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIn fire conditions, non chlorinated flame retardant system produces. \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLess toxic and less corrosive gasses.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eDual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 \u003c\/span\u003e\u003cspan\u003eType X110.\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eHighest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, \u003c\/span\u003e\u003cspan\u003eTransport Canada 95°C\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSevere cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFlame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor uses all over the world it is designed and constructed for the demanding environments of offshore drilling and petroleum facilities. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCONDUCTOR:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eINSULATION\/JACKET: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFlame Retardant Cross-linked Polyolefin, meeting the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRATINGS \u0026amp; APPROVALS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eNVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eTRANSPORT CANADA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eDET NORSKE VERITAS (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eLLOYDE'S REGISTER OF SHIPPIN (LRS)\u003c\/li\u003e\n\u003cli\u003eAMERICAN BUREAU OF SHIPPING (ABS)\u003c\/li\u003e\n\u003cli\u003eUL LISTED AS MARINE SHIPBOARD CABLE\u003c\/li\u003e\n\u003cli\u003eUNITED STATES COAST GUARD  \u003c\/li\u003e\n\u003cli\u003eCSA LISTED AS MARINE SHIPBOARD CABLE \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cgdiv\u003e\u003c\/gdiv\u003e\u003ciframe style=\"display: none;\" class=\"ginger-extension-definitionpopup\"\u003e\u003c\/iframe\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27521946812516,"sku":"NNC4938X","price":8.65,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/60_3b532715-8a1e-48cf-a239-6b53f743373e.png?v=1762459680"},{"product_id":"1-four-con-p-1k-600k","title":"1\/4 UNARMORED TYPE P DRILLING RIG MARINE POWER CABLE 600V \/ 1000Kv","description":"\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch2\u003e1\/4 Unarmored Type P Drilling Rig Marine Power Cable 600v \/ 1000kv\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity For 1\/4 Unarmored Type P Drilling Rig Marine Power Cable 600V \/ 1000kV \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 153 Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e105ºC, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e143 Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e100ºC, 131 Amps at 90ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eType P Drilling Rig Marine Power Cable is an electrical cable designed for multipurpose use in offshore and onshore drilling and petroleum facilities. Typical applications include power, control, instrumentation, and communication. Type P cables demonstrate excellent capacity in demanding conditions, including extreme cold, heat, vibration, drilling, corrosion, and mechanical stress. The electrical cables are flame-retardant and resistant to moisture. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e1\/4 Unarmored Type P Rig Cable, 1\/4 Unarmored Type P Cable, 1\/4 Unarmored  Type P Drilling Rig and Marine Cable, 1\/4 Unarmored Type Rig Cable, 1\/4 Unarmored Type P Polyrad Oil Gas XLPO\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Dual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Highest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Severe cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Flame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• NVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Transport Canada\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• DET Norske Veritas (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Llloyde's Register Of Shipping (LRS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• American Bureau Of Shipping (ABS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• UL Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• United States Coast Guard\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• CSA Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eConductor:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eHigh strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial cables.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eInsulation\/Jacket:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eFlame Retardant Cross-linked Polyolefin meets the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e• AWG Size: 1\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• MM2: 43\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Nominal Diameter (inches): 1.332\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Net Weight (Lbs\/1000 FT): 1602\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e [\/short]\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFEATURES:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003eHigh strand count conductors make this product extremely flexible, \u003c\/span\u003e\u003cspan\u003eeasier to install and more resistant to vibration than Type MC, IEC \u003c\/span\u003e\u003cspan\u003espec or commercial cables.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eLower dielectric constant and higher insulation resistance reduces \u003c\/span\u003e\u003cspan\u003eelectrical losses.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eExcellent resistance to moisture produces stable electrical properties \u003c\/span\u003e\u003cspan\u003ethroughout the life of the cable.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIn fire conditions, non chlorinated flame retardant system produces. \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLess toxic and less corrosive gasses.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eDual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 \u003c\/span\u003e\u003cspan\u003eType X110.\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eHighest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, \u003c\/span\u003e\u003cspan\u003eTransport Canada 95°C\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSevere cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFlame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor uses all over the world it is designed and constructed for the demanding environments of offshore drilling and petroleum facilities. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCONDUCTOR:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eINSULATION\/JACKET: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFlame Retardant Cross-linked Polyolefin, meeting the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRATINGS \u0026amp; APPROVALS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eNVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eTRANSPORT CANADA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eDET NORSKE VERITAS (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eLLOYDE'S REGISTER OF SHIPPIN (LRS)\u003c\/li\u003e\n\u003cli\u003eAMERICAN BUREAU OF SHIPPING (ABS)\u003c\/li\u003e\n\u003cli\u003eUL LISTED AS MARINE SHIPBOARD CABLE\u003c\/li\u003e\n\u003cli\u003eUNITED STATES COAST GUARD  \u003c\/li\u003e\n\u003cli\u003eCSA LISTED AS MARINE SHIPBOARD CABLE \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27521947041892,"sku":"NNC4943X","price":32.49,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/60_109475df-264b-4b94-a1a5-92e7e7aac6bd.png?v=1762459683"},{"product_id":"1-0-4-unarmored-type-p-drilling-rig-marine-power-cable-600v-1000kv","title":"1\/0-4 Unarmored Type P Drilling Rig Marine Power Cable 600V\/1000kV","description":"\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch2\u003e1\/0-4 Unarmored Type P Drilling Rig Marine Power Cable 600v \/ 1000kv\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity For 1\/0-4 Unarmored Type P Drilling Rig Marine Power Cable 600V \/ 1000kV \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 176 Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e105ºC, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e164 Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e100ºC, 152 Amps at 90ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eType P Drilling Rig Marine Power Cable is an electrical cable designed for multipurpose use in offshore and onshore drilling and petroleum facilities. Typical applications include power, control, instrumentation, and communication. Type P cables demonstrate excellent capacity in demanding conditions, including extreme cold, heat, vibration, drilling, corrosion, and mechanical stress. The electrical cables are flame-retardant and resistant to moisture. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e1\/0-4 Unarmored Type P Rig Cable, 1\/0-4 Unarmored Type P Cable, 1\/0-4 Unarmored Type P Drilling Rig and Marine Cable, 1\/0-4 Unarmored Type Rig Cable, 1\/0-4 Unarmored Type P Polyrad Oil Gas XLPO\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Dual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Highest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Severe cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Flame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• NVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Transport Canada\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• DET Norske Veritas (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Llloyde's Register Of Shipping (LRS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• American Bureau Of Shipping (ABS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• UL Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• United States Coast Guard\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• CSA Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eConductor:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eHigh strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial cables.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eInsulation\/Jacket:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eFlame Retardant Cross-linked Polyolefin meets the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e• AWG Size: 1\/0\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• MM2: 54\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Nominal Diameter (inches): 1.465\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Net Weight (Lbs\/1000 FT): 1907\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e[\/short]\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFEATURES:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003eHigh strand count conductors make this product extremely flexible, \u003c\/span\u003e\u003cspan\u003eeasier to install and more resistant to vibration than Type MC, IEC \u003c\/span\u003e\u003cspan\u003espec or commercial cables.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eLower dielectric constant and higher insulation resistance reduces \u003c\/span\u003e\u003cspan\u003eelectrical losses.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eExcellent resistance to moisture produces stable electrical properties \u003c\/span\u003e\u003cspan\u003ethroughout the life of the cable.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIn fire conditions, non chlorinated flame retardant system produces. \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLess toxic and less corrosive gasses.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eDual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 \u003c\/span\u003e\u003cspan\u003eType X110.\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eHighest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, \u003c\/span\u003e\u003cspan\u003eTransport Canada 95°C\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSevere cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFlame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor uses all over the world it is designed and constructed for the demanding environments of offshore drilling and petroleum facilities. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCONDUCTOR:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eINSULATION\/JACKET: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFlame Retardant Cross-linked Polyolefin, meeting the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRATINGS \u0026amp; APPROVALS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eNVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eTRANSPORT CANADA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eDET NORSKE VERITAS (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eLLOYDE'S REGISTER OF SHIPPIN (LRS)\u003c\/li\u003e\n\u003cli\u003eAMERICAN BUREAU OF SHIPPING (ABS)\u003c\/li\u003e\n\u003cli\u003eUL LISTED AS MARINE SHIPBOARD CABLE\u003c\/li\u003e\n\u003cli\u003eUNITED STATES COAST GUARD  \u003c\/li\u003e\n\u003cli\u003eCSA LISTED AS MARINE SHIPBOARD CABLE \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e","brand":"Nassau National cable","offers":[{"title":"Default Title","offer_id":27521947107428,"sku":"NNC4944X","price":45.56,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/60_02ab1884-6aa0-48ae-8df9-acf5791e91c8.png?v=1762459684"},{"product_id":"10-four-con-armorp-1k-600k","title":"10\/4 ARMORED TYPE P DRILLING RIG MARINE POWER CABLE 600V \/ 1000Kv","description":"\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch2\u003e10-4 Armored Type P Drilling Rig Marine Power Cable 600V \/ 1000kV\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity For 10-4 Armored Type P Drilling Rig Marine Power Cable 600V \/ 1000kV \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 44 Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e105ºC, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e41 Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e100ºC, 36 Amps at 90ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eType P Drilling Rig Marine Power Cable is an electrical cabledesigned for multipurpose use in offshore and onshore drilling and petroleum facilities. Typical applications include power, control, instrumentation, and communication. Type P cables demonstrate excellent capacity in demanding conditions, including extreme cold, heat, vibration, drilling, corrosion, and mechanical stress. The electrical cables are flame-retardant and resistant to moisture. They are armored with a \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003ebasket weave wire armor per IEEE 1580 and UL 1309\/CSA C22.2 No. 245\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e10\/4 Type P Rig Cable, 10\/4 Type P Cable, 10\/4 Type P Drilling Rig and Marine Cable, 10\/4 Rig Cable, 10\/4 Type P Polyrad Oil Gas XLPO, 10\/4 Type P Power Cable, 10\/4 Type P Armored, 10\/4 Shipboard Cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Dual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Highest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Severe cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Flame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• NVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Transport Canada\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e•  DET Norske Veritas (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Llloyde's Register Of Shipping (LRS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• American Bureau Of Shipping (ABS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• UL Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• United States Coast Guard\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• CSA Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eConductor:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eHigh strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial cables.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eInsulation\/Jacket:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eFlame Retardant Cross-linked Polyolefin meets the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e• AWG Size: 10  \u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• MM2: 5.2  \u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Nominal Diameter (inches): 0.603\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Net Weight (Lbs\/1000 FT): 313 \u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e[\/short]\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFEATURES:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003eHigh strand count conductors make this product extremely flexible, \u003c\/span\u003e\u003cspan\u003eeasier to install and more resistant to vibration than Type MC, IEC \u003c\/span\u003e\u003cspan\u003espec or commercial cables.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eLower dielectric constant and higher insulation resistance reduces \u003c\/span\u003e\u003cspan\u003eelectrical losses.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eExcellent resistance to moisture produces stable electrical properties \u003c\/span\u003e\u003cspan\u003ethroughout the life of the cable.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIn fire conditions, non chlorinated flame retardant system produces. \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLess toxic and less corrosive gasses.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eDual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 \u003c\/span\u003e\u003cspan\u003eType X110.\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eHighest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, \u003c\/span\u003e\u003cspan\u003eTransport Canada 95°C\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSevere cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFlame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor uses all over the world it is designed and constructed for the demanding environments of offshore drilling and petroleum facilities. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCONDUCTOR:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eARMOR:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBasket weave wire armor per IEEE 1580 and UL 1309\/CSA C22.2 No. 245. Bronze standard. Tinned copper available by request.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eINSULATION\/JACKET: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFlame Retardant Cross-linked Polyolefin, meeting the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRATINGS \u0026amp; APPROVALS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eNVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eTRANSPORT CANADA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eDET NORSKE VERITAS (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eLLOYDE'S REGISTER OF SHIPPIN (LRS)\u003c\/li\u003e\n\u003cli\u003eAMERICAN BUREAU OF SHIPPING (ABS)\u003c\/li\u003e\n\u003cli\u003eUL LISTED AS MARINE SHIPBOARD CABLE\u003c\/li\u003e\n\u003cli\u003eUNITED STATES COAST GUARD  \u003c\/li\u003e\n\u003cli\u003eCSA LISTED AS MARINE SHIPBOARD CABLE \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e\n\u003cdiv id=\"gtx-trans\" style=\"position: absolute; left: -15px; top: 932.833px;\"\u003e\n\u003cdiv class=\"gtx-trans-icon\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cgdiv\u003e\u003c\/gdiv\u003e","brand":"Nassau National cable","offers":[{"title":"Default Title","offer_id":27521948680292,"sku":"NNC4957X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/60_7cdea6d3-f3b8-4921-8d8e-8825a2c01dd8.png?v=1762459692"},{"product_id":"1-four-con-armorp-1k-600k","title":"1\/4 ARMORED TYPE P DRILLING RIG MARINE POWER CABLE 600V \/ 1000Kv","description":"\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch2\u003e1-4 Armored Type P Drilling Rig Marine Power Cable 600V \/ 1000kV\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity For 1-4 Armored Type P Drilling Rig Marine Power Cable 600V \/ 1000kV \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 153 Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e105ºC, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e143 Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e100ºC, 131 Amps at 90ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eType P Drilling Rig Marine Power Cable is an electrical cable designed for multipurpose use in offshore and onshore drilling and petroleum facilities. Typical applications include power, control, instrumentation, and communication. Type P cables demonstrate excellent capacity in demanding conditions, including extreme cold, heat, vibration, drilling, corrosion, and mechanical stress. The electrical cables are flame-retardant and resistant to moisture. They are armored with a \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003ebasket weave wire armor per IEEE 1580 and UL 1309\/CSA C22.2 No. 245\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e1\/4 Type P Rig Cable, 1\/4 Type P Cable, 1\/4 Type P Drilling Rig and Marine Cable, 1\/4 Rig Cable, 1\/4 Type P Polyrad Oil Gas XLPO, 1\/4 Type P Power Cable, 1\/4 Type P Armored, 1\/4 Shipboard Cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Dual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Highest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Severe cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Flame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• NVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Transport Canada\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• DET Norske Veritas (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Llloyde's Register Of Shipping (LRS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• American Bureau Of Shipping (ABS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• UL Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• United States Coast Guard\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• CSA Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eConductor:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eHigh strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial cables.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eInsulation\/Jacket:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eFlame Retardant Cross-linked Polyolefin meets the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e• AWG Size: 1  \u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• MM2: 43  \u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Nominal Diameter (inches): 1.382\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Net Weight (Lbs\/1000 FT): 1909\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e[\/short]\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFEATURES:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003eHigh strand count conductors make this product extremely flexible, \u003c\/span\u003e\u003cspan\u003eeasier to install and more resistant to vibration than Type MC, IEC \u003c\/span\u003e\u003cspan\u003espec or commercial cables.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eLower dielectric constant and higher insulation resistance reduces \u003c\/span\u003e\u003cspan\u003eelectrical losses.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eExcellent resistance to moisture produces stable electrical properties \u003c\/span\u003e\u003cspan\u003ethroughout the life of the cable.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIn fire conditions, non chlorinated flame retardant system produces. \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLess toxic and less corrosive gasses.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eDual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 \u003c\/span\u003e\u003cspan\u003eType X110.\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eHighest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, \u003c\/span\u003e\u003cspan\u003eTransport Canada 95°C\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSevere cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFlame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor uses all over the world it is designed and constructed for the demanding environments of offshore drilling and petroleum facilities. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCONDUCTOR:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eARMOR:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBasket weave wire armor per IEEE 1580 and UL 1309\/CSA C22.2 No. 245. Bronze standard. Tinned copper available by request.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eINSULATION\/JACKET: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFlame Retardant Cross-linked Polyolefin, meeting the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRATINGS \u0026amp; APPROVALS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eNVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eTRANSPORT CANADA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eDET NORSKE VERITAS (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eLLOYDE'S REGISTER OF SHIPPIN (LRS)\u003c\/li\u003e\n\u003cli\u003eAMERICAN BUREAU OF SHIPPING (ABS)\u003c\/li\u003e\n\u003cli\u003eUL LISTED AS MARINE SHIPBOARD CABLE\u003c\/li\u003e\n\u003cli\u003eUNITED STATES COAST GUARD  \u003c\/li\u003e\n\u003cli\u003eCSA LISTED AS MARINE SHIPBOARD CABLE \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e\n\u003cdiv id=\"gtx-trans\" style=\"position: absolute; left: -10px; top: 885.167px;\"\u003e\n\u003cdiv class=\"gtx-trans-icon\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cgdiv\u003e\u003c\/gdiv\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27521949106276,"sku":"NNC4962X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/60_d25fcc56-c90e-4ea7-95d8-0b8ce69320db.png?v=1762459696"},{"product_id":"1-0-four-con-armorp-1k-600k","title":"1\/0-4 ARMORED TYPE P DRILLING RIG MARINE POWER CABLE 600V \/ 1000Kv","description":"\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch2\u003e1\/0-4 Armored Type P Drilling Rig Marine Power Cable 600V \/ 1000kV\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity For 1\/0-4 Armored Type P Drilling Rig Marine Power Cable 600V \/ 1000kV \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003e: 176 Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003e105ºC, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003e164 Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003e100ºC, 152 Amps at 90ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003eType P Drilling Rig Marine Power Cable is an electrical cable designed for multipurpose use in offshore and onshore drilling and petroleum facilities. Typical applications include power, control, instrumentation, and communication. Type P cables demonstrate excellent capacity in demanding conditions, including extreme cold, heat, vibration, drilling, corrosion, and mechanical stress. The electrical cables are flame-retardant and resistant to moisture. They are armored with a \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003ebasket weave wire armor per IEEE 1580 and UL 1309\/CSA C22.2 No. 245\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003e1\/0-4 Type P Rig Cable, 1\/0-4 Type P Cable, 1\/0-4 Type P Drilling Rig and Marine Cable, 1\/0-4 Rig Cable, 1\/0-4 Type P Polyrad Oil Gas XLPO, 1\/0-4 Type P Power Cable, 1\/0-4 Type P Armored, 1\/0-4 Shipboard Cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003e• Dual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003e• Highest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003e• Severe cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003e• Flame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003e• NVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003e• Transport Canada\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003e• DET Norske Veritas (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003e• Llloyde's Register Of Shipping (LRS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003e• American Bureau Of Shipping (ABS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003e• UL Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003e• United States Coast Guard\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003e• CSA Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eConductor:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003eHigh strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial cables.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eInsulation\/Jacket:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\" data-mce-style=\"font-weight: 400;\"\u003eFlame Retardant Cross-linked Polyolefin meets the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e• AWG Size: 1\/0   \u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• MM2: 54\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Nominal Diameter (inches): 1.515\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Net Weight (Lbs\/1000 FT): 2180\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFEATURES:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003eHigh strand count conductors make this product extremely flexible, \u003c\/span\u003e\u003cspan\u003eeasier to install and more resistant to vibration than Type MC, IEC \u003c\/span\u003e\u003cspan\u003espec or commercial cables.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eLower dielectric constant and higher insulation resistance reduces \u003c\/span\u003e\u003cspan\u003eelectrical losses.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eExcellent resistance to moisture produces stable electrical properties \u003c\/span\u003e\u003cspan\u003ethroughout the life of the cable.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIn fire conditions, non chlorinated flame retardant system produces. \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLess toxic and less corrosive gasses.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eDual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 \u003c\/span\u003e\u003cspan\u003eType X110.\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eHighest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, \u003c\/span\u003e\u003cspan\u003eTransport Canada 95°C\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSevere cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFlame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor uses all over the world it is designed and constructed for the demanding environments of offshore drilling and petroleum facilities. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCONDUCTOR:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eARMOR:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBasket weave wire armor per IEEE 1580 and UL 1309\/CSA C22.2 No. 245. Bronze standard. Tinned copper available by request.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eINSULATION\/JACKET: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFlame Retardant Cross-linked Polyolefin, meeting the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRATINGS \u0026amp; APPROVALS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\" data-mce-style=\"font-size: 12px;\"\u003eNVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\" data-mce-style=\"font-size: 12px;\"\u003eTRANSPORT CANADA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\" data-mce-style=\"font-size: 12px;\"\u003eDET NORSKE VERITAS (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eLLOYDE'S REGISTER OF SHIPPIN (LRS)\u003c\/li\u003e\n\u003cli\u003eAMERICAN BUREAU OF SHIPPING (ABS)\u003c\/li\u003e\n\u003cli\u003eUL LISTED AS MARINE SHIPBOARD CABLE\u003c\/li\u003e\n\u003cli\u003eUNITED STATES COAST GUARD  \u003c\/li\u003e\n\u003cli\u003eCSA LISTED AS MARINE SHIPBOARD CABLE \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e\n\u003cdiv style=\"position: absolute; left: -12px; top: 885.167px;\" id=\"gtx-trans\" data-mce-style=\"position: absolute; left: -12px; top: 885.167px;\"\u003e\n\u003cdiv class=\"gtx-trans-icon\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cgdiv\u003e\u003c\/gdiv\u003e","brand":"Nassau National cable","offers":[{"title":"Default Title","offer_id":27521949171812,"sku":"NNC4963X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/60_77d65d45-c455-46c2-b1d2-c2ea514ca64e.png?v=1762459696"},{"product_id":"10-four-con-armorp-shea-1k-600k","title":"10\/4 Armored \u0026 Sheathed Type P Drilling Rig Marine Power Cable 600V \/ 1000KV","description":"\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch2\u003e10\/4 Armored \u0026amp; Sheathed Type P Drilling Rig Marine Power Cable 600v \/1000kv\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity For 10\/4 Armored \u0026amp; Sheathed Type P Drilling Rig Marine Power Cable 600V \/ 1000kV \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 44 Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e105ºC, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e41 Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e100ºC, 36 Amps at 90ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eType P Drilling Rig Marine Power Cable is an electrical cable designed for multipurpose use in offshore and onshore drilling and petroleum facilities. Typical applications include power, control, instrumentation, and communication. Type P cables demonstrate excellent capacity in demanding conditions, including extreme cold, heat, vibration, drilling, corrosion, and mechanical stress. The electrical cables are flame-retardant and resistant to moisture. It is armored with a \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003ebasket weave wire armor per IEEE 1580 and UL 1309\/CSA C22.2 No. 245, and sheathed with a black, arctic grade, flame retardant, oil abrasion, chemical and sunlight resistant thermosetting compound meeting UL 1309 \/ CSA c22.2 No. 245 and IEEE 1580. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e10\/4 Armored And Sheathed Type P Rig Cable, 10\/4 Armored And Sheathed Type Type P Cable, 10\/4 Armored And Sheathed Type Type P Drilling Rig and Marine Cable, 10\/4 Armored And Sheathed Type Rig Cable, 10\/4 Armored And Sheathed Type P Polyrad Oil Gas XLPO\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Dual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Highest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Severe cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Flame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• NVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Transport Canada\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• DET Norske Veritas (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Llloyde's Register Of Shipping (LRS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• American Bureau Of Shipping (ABS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• UL Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• United States Coast Guard\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• CSA Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eConductor:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eHigh strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial cables.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eInsulation\/Jacket:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eFlame Retardant Cross-linked Polyolefin meets the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e• AWG Size: 10\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• MM2: 5.2\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Nominal Diameter (inches): 0.734\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Net Weight (Lbs\/1000 FT): 323 \u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e[\/short]\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFEATURES:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003eHigh strand count conductors make this product extremely flexible, \u003c\/span\u003e\u003cspan\u003eeasier to install and more resistant to vibration than Type MC, IEC \u003c\/span\u003e\u003cspan\u003espec or commercial cables.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eLower dielectric constant and higher insulation resistance reduces \u003c\/span\u003e\u003cspan\u003eelectrical losses.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eExcellent resistance to moisture produces stable electrical properties \u003c\/span\u003e\u003cspan\u003ethroughout the life of the cable.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIn fire conditions, non chlorinated flame retardant system produces. \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLess toxic and less corrosive gasses.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eDual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 \u003c\/span\u003e\u003cspan\u003eType X110.\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eHighest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, \u003c\/span\u003e\u003cspan\u003eTransport Canada 95°C\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSevere cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFlame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor uses all over the world it is designed and constructed for the demanding environments of offshore drilling and petroleum facilities. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCONDUCTOR:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eARMOR:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBasket weave wire armor per IEEE 1580 and UL 1309\/CSA C22.2 No. 245. Bronze standard. Tinned copper available by request.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSHEATH:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA black, arctic grade, flame retardant, oil abrasion, chemical and sunlight resistant thermosetting compound meeting UL 1309\/CSA C22.2 No. 245 and IEEE 1580.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eINSULATION\/JACKET: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFlame Retardant Cross-linked Polyolefin, meeting the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRATINGS \u0026amp; APPROVALS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eNVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eTRANSPORT CANADA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eDET NORSKE VERITAS (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eLLOYDE'S REGISTER OF SHIPPIN (LRS)\u003c\/li\u003e\n\u003cli\u003eAMERICAN BUREAU OF SHIPPING (ABS)\u003c\/li\u003e\n\u003cli\u003eUL LISTED AS MARINE SHIPBOARD CABLE\u003c\/li\u003e\n\u003cli\u003eUNITED STATES COAST GUARD  \u003c\/li\u003e\n\u003cli\u003eCSA LISTED AS MARINE SHIPBOARD CABLE \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e","brand":"Nassau National cable","offers":[{"title":"Default Title","offer_id":27521951400036,"sku":"NNC4977X","price":18.93,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/60_6602edcc-f988-4b0a-a4ef-0de9af6abfa1.png?v=1762459707"},{"product_id":"1-four-con-armorp-shea-1k-600k","title":"1\/4 ARMORED \u0026 SHEATHED TYPE P DRILLING RIG MARINE POWER CABLE 600V \/ 1000Kv","description":"\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch2\u003e1\/4 Armored \u0026amp; Sheathed Type P Drilling Rig Marine Power Cable 600V \/ 1000kV\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity For 1\/4 Armored \u0026amp; Sheathed Type P Drilling Rig Marine Power Cable 600V \/ 1000kV \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 153 Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e105ºC, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e143 Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e100ºC, 131 Amps at 90ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eType P Drilling Rig Marine Power Cable is an electrical cable designed for multipurpose use in offshore and onshore drilling and petroleum facilities. Typical applications include power, control, instrumentation, and communication. Type P cables demonstrate excellent capacity in demanding conditions, including extreme cold, heat, vibration, drilling, corrosion, and mechanical stress. The electrical cables are flame-retardant and resistant to moisture. It is armored with a \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003ebasket weave wire armor per IEEE 1580 and UL 1309\/CSA C22.2 No. 245, and sheathed with a black, arctic grade, flame retardant, oil abrasion, chemical and sunlight resistant thermosetting compound meeting UL 1309 \/ CSA c22.2 No. 245 and IEEE 1580. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e1\/4 Type P Rig Cable, 1\/4 Type P Cable, 1\/4 Type P Drilling Rig and Marine Cable, 1\/4 Rig Cable, 1\/4 Type P Polyrad Oil Gas XLPO, 1\/4 Type P Power Cable, 1\/4 Type P Armored Sheathed, 1\/4 Shipboard Cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Dual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Highest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Severe cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Flame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• NVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Transport Canada\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• DET Norske Veritas (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Llloyde's Register Of Shipping (LRS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• American Bureau Of Shipping (ABS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• UL Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• United States Coast Guard\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• CSA Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eConductor:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eHigh strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial cables.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eInsulation\/Jacket:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eFlame Retardant Cross-linked Polyolefin meets the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e• AWG Size: 1\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• MM2: 43\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Nominal Diameter (inches): 1.555\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Net Weight (Lbs\/1000 FT): 2144\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e[\/short]\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFEATURES:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003eHigh strand count conductors make this product extremely flexible, \u003c\/span\u003e\u003cspan\u003eeasier to install and more resistant to vibration than Type MC, IEC \u003c\/span\u003e\u003cspan\u003espec or commercial cables.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eLower dielectric constant and higher insulation resistance reduces \u003c\/span\u003e\u003cspan\u003eelectrical losses.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eExcellent resistance to moisture produces stable electrical properties \u003c\/span\u003e\u003cspan\u003ethroughout the life of the cable.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIn fire conditions, non chlorinated flame retardant system produces. \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLess toxic and less corrosive gasses.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eDual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 \u003c\/span\u003e\u003cspan\u003eType X110.\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eHighest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, \u003c\/span\u003e\u003cspan\u003eTransport Canada 95°C\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSevere cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFlame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor uses all over the world it is designed and constructed for the demanding environments of offshore drilling and petroleum facilities. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCONDUCTOR:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eARMOR:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBasket weave wire armor per IEEE 1580 and UL 1309\/CSA C22.2 No. 245. Bronze standard. Tinned copper available by request.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSHEATH:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA black, arctic grade, flame retardant, oil abrasion, chemical and sunlight resistant thermosetting compound meeting UL 1309\/CSA C22.2 No. 245 and IEEE 1580.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eINSULATION\/JACKET: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFlame Retardant Cross-linked Polyolefin, meeting the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRATINGS \u0026amp; APPROVALS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eNVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eTRANSPORT CANADA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eDET NORSKE VERITAS (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eLLOYDE'S REGISTER OF SHIPPIN (LRS)\u003c\/li\u003e\n\u003cli\u003eAMERICAN BUREAU OF SHIPPING (ABS)\u003c\/li\u003e\n\u003cli\u003eUL LISTED AS MARINE SHIPBOARD CABLE\u003c\/li\u003e\n\u003cli\u003eUNITED STATES COAST GUARD  \u003c\/li\u003e\n\u003cli\u003eCSA LISTED AS MARINE SHIPBOARD CABLE \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e\n\u003cdiv id=\"gtx-trans\" style=\"position: absolute; left: -6px; top: 943.167px;\"\u003e\n\u003cdiv class=\"gtx-trans-icon\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cgdiv\u003e\u003c\/gdiv\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27521951891556,"sku":"NNC4982X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/60_1fdb9da7-9265-46e0-99be-1968f312fed8.png?v=1762459709"},{"product_id":"1-0-four-con-armorp-shea-1k-600k","title":"1\/0-4 Armored \u0026 Sheathed Type P Drilling Rig Marine Power Cable 600V \/ 1000KV","description":"\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch2\u003e1\/0-4 Armored \u0026amp; Sheathed Type P Drilling Rig Marine Power Cable 600v \/1000kv\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity For 1\/0-4 Armored \u0026amp; Sheathed Type P Drilling Rig Marine Power Cable 600V \/ 1000kV \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 176 Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e105ºC, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e164 Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e100ºC, 152 Amps at 90ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eType P Drilling Rig Marine Power Cable is an electrical cable designed for multipurpose use in offshore and onshore drilling and petroleum facilities. Typical applications include power, control, instrumentation, and communication. Type P cables demonstrate excellent capacity in demanding conditions, including extreme cold, heat, vibration, drilling, corrosion, and mechanical stress. The electrical cables are flame-retardant and resistant to moisture. It is armored with a \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003ebasket weave wire armor per IEEE 1580 and UL 1309\/CSA C22.2 No. 245, and sheathed with a black, arctic grade, flame retardant, oil abrasion, chemical and sunlight resistant thermosetting compound meeting UL 1309 \/ CSA c22.2 No. 245 and IEEE 1580. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e1\/0-4 Armored And Sheathed Type P Rig Cable, 1\/0-4 Armored And Sheathed Type Type P Cable, 1\/0-4 Armored And Sheathed Type Type P Drilling Rig and Marine Cable, 1\/0-4 Armored And Sheathed Type Rig Cable, 1\/0-4 Armored And Sheathed Type P Polyrad Oil Gas XLPO\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Dual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Highest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Severe cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Flame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• NVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Transport Canada\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• DET Norske Veritas (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Llloyde's Register Of Shipping (LRS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• American Bureau Of Shipping (ABS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• UL Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• United States Coast Guard\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• CSA Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eConductor:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eHigh strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial cables.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eInsulation\/Jacket:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eFlame Retardant Cross-linked Polyolefin meets the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e• AWG Size: 1\/0\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• MM2: 54\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Nominal Diameter (inches): 1.750\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Net Weight (Lbs\/1000 FT): 2434\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e[\/short]\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFEATURES:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003eHigh strand count conductors make this product extremely flexible, \u003c\/span\u003e\u003cspan\u003eeasier to install and more resistant to vibration than Type MC, IEC \u003c\/span\u003e\u003cspan\u003espec or commercial cables.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eLower dielectric constant and higher insulation resistance reduces \u003c\/span\u003e\u003cspan\u003eelectrical losses.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eExcellent resistance to moisture produces stable electrical properties \u003c\/span\u003e\u003cspan\u003ethroughout the life of the cable.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIn fire conditions, non chlorinated flame retardant system produces. \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLess toxic and less corrosive gasses.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eDual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 \u003c\/span\u003e\u003cspan\u003eType X110.\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eHighest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, \u003c\/span\u003e\u003cspan\u003eTransport Canada 95°C\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSevere cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFlame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor uses all over the world it is designed and constructed for the demanding environments of offshore drilling and petroleum facilities. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCONDUCTOR:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eARMOR:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBasket weave wire armor per IEEE 1580 and UL 1309\/CSA C22.2 No. 245. Bronze standard. Tinned copper available by request.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSHEATH:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA black, arctic grade, flame retardant, oil abrasion, chemical and sunlight resistant thermosetting compound meeting UL 1309\/CSA C22.2 No. 245 and IEEE 1580.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eINSULATION\/JACKET: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFlame Retardant Cross-linked Polyolefin, meeting the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRATINGS \u0026amp; APPROVALS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eNVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eTRANSPORT CANADA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eDET NORSKE VERITAS (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eLLOYDE'S REGISTER OF SHIPPIN (LRS)\u003c\/li\u003e\n\u003cli\u003eAMERICAN BUREAU OF SHIPPING (ABS)\u003c\/li\u003e\n\u003cli\u003eUL LISTED AS MARINE SHIPBOARD CABLE\u003c\/li\u003e\n\u003cli\u003eUNITED STATES COAST GUARD  \u003c\/li\u003e\n\u003cli\u003eCSA LISTED AS MARINE SHIPBOARD CABLE \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e","brand":"Nassau National cable","offers":[{"title":"Default Title","offer_id":27521951957092,"sku":"NNC4983X","price":52.09,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/60_0f087c60-581f-4b18-8e4e-18aa705931b4.png?v=1762459711"},{"product_id":"10-five-co-armorp-shea-1k-600k","title":"10\/5 Unarmored Control Type P Drilling Rig Marine Power Cable 600V \/ 1000Kv","description":"\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch2\u003e10\/5 Unarmored Control Type P Drilling Rig Marine Power Cable 600v \/ 1000kv\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity For 10\/5 Unarmored Type P Drilling Rig Marine Power Cable 600V \/ 1000kV \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 35 Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e105ºC, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e33 Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e100ºC, 29 Amps at 90ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eType P Drilling Rig Marine Power Cable is an electrical cable designed for multipurpose use in offshore and onshore drilling and petroleum facilities. Typical applications include power, control, instrumentation, and communication. Type P cables demonstrate excellent capacity in demanding conditions, including extreme cold, heat, vibration, drilling, corrosion, and mechanical stress. The electrical cables are flame-retardant and resistant to moisture. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e10\/5 Type P Rig Cable, 10\/5 Type P Cable, 10\/5 Type P Drilling Rig and Marine Cable, 10\/5 Rig Cable, 10\/5 Type P Polyrad Oil Gas XLPO, 10\/5 Type P Power Cable, 10\/5 Type P Unarmored, 10\/5 Type P Control Cable, 10\/5 Shipboard Cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Dual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Highest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Severe cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Flame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• NVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Transport Canada\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• DET Norske Veritas (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Llloyde's Register Of Shipping (LRS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• American Bureau Of Shipping (ABS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• UL Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• United States Coast Guard\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• CSA Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eConductor:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eHigh strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial cables.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eInsulation\/Jacket:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eFlame Retardant Cross-linked Polyolefin meets the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e• AWG Size: 10\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• MM2: 5.2\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Nominal Diameter (inches): 0.604\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Net Weight (Lbs\/1000 FT): 296\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e[\/short]\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFEATURES:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003eHigh strand count conductors make this product extremely flexible, \u003c\/span\u003e\u003cspan\u003eeasier to install and more resistant to vibration than Type MC, IEC \u003c\/span\u003e\u003cspan\u003espec or commercial cables.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eLower dielectric constant and higher insulation resistance reduces \u003c\/span\u003e\u003cspan\u003eelectrical losses.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eExc cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFlame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor uses all over the world it is designed and constructed for the demanding environments of offshore drilling and petroleum facilities. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCONDUCTOR:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eINSULATION\/JACKET: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFlame Retardant Cross-linked Polyolefin, meeting the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRATINGS \u0026amp; APPROVALS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eNVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eTRANSPORT CANADA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eDET NORSKE VERITAS (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eLLOYDE'S REGISTER OF SHIPPIN (LRS)\u003c\/li\u003e\n\u003cli\u003eAMERICAN BUREAU OF SHIPPING (ABS)\u003c\/li\u003e\n\u003cli\u003eUL LISTED AS MARINE SHIPBOARD CABLE\u003c\/li\u003e\n\u003cli\u003eUNITED STATES COAST GUARD  \u003c\/li\u003e\n\u003cli\u003eCSA LISTED AS MARINE SHIPBOARD CABLE \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e\n\u003cdiv style=\"position: absolute; left: -10px; top: 913.5px;\" id=\"gtx-trans\"\u003e\n\u003cdiv class=\"gtx-trans-icon\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cgdiv\u003e\u003c\/gdiv\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27521955823716,"sku":"NNC5001X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/five_type_p_d2811c7d-424b-4e6c-bc6e-8dd1f2541cdc.png?v=1762459723"},{"product_id":"1-0-5-unarmored-control-type-p-drilling-rig-marine-power-cable-600v-1000kv","title":"1\/0-5 Unarmored Control Type P Drilling Rig Marine Power Cable 600V \/ 1000Kv","description":"\u003cp\u003e[short]\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e1\/0-5 Unarmored Control Type P Drilling Rig Marine Power Cable 600v \/ 1000kv\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity For 1\/0-5 Unarmored Type P Drilling Rig Marine Power Cable 600V \/ 1000kV \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 140 Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e105ºC, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e131 Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e100ºC, 122 Amps at 90ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eType P Drilling Rig Marine Power Cable is an electrical cable designed for multipurpose use in offshore and onshore drilling and petroleum facilities. Typical applications include power, control, instrumentation, and communication. Type P electrical cables demonstrate excellent capacity in demanding conditions, including extreme cold, heat, vibration, drilling, corrosion, and mechanical stress. The cables are flame-retardant and resistant to moisture. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e1\/0-5 Type P Rig Cable, 1\/0-5 Type P Cable, 1\/0-5 Type P Drilling Rig and Marine Cable, 1\/0-5 Rig Cable, 1\/0-5 Type P Polyrad Oil Gas XLPO, 1\/0-5 Type P Power Cable, 1\/0-5 Type P Unarmored, 1\/0-5 Type P Control Cable, 1\/0-5 Shipboard Cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Dual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Highest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Severe cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Flame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• NVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Transport Canada\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• DET Norske Veritas (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Llloyde's Register Of Shipping (LRS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• American Bureau Of Shipping (ABS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• UL Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• United States Coast Guard\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• CSA Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eConductor:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eHigh strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial cables.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eInsulation\/Jacket:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eFlame Retardant Cross-linked Polyolefin meets the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e• AWG Size: 1\/0\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• MM2: 54\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Nominal Diameter (inches): 1.618\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Net Weight (Lbs\/1000 FT): 2550\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e[\/short]\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFEATURES:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003eHigh strand count conductors make this product extremely flexible, \u003c\/span\u003e\u003cspan\u003eeasier to install and more resistant to vibration than Type MC, IEC \u003c\/span\u003e\u003cspan\u003espec or commercial cables.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eLower dielectric constant and higher insulation resistance reduces \u003c\/span\u003e\u003cspan\u003eelectrical losses.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eExc cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFlame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor uses all over the world it is designed and constructed for the demanding environments of offshore drilling and petroleum facilities. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCONDUCTOR:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eINSULATION\/JACKET: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFlame Retardant Cross-linked Polyolefin, meeting the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRATINGS \u0026amp; APPROVALS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eNVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eTRANSPORT CANADA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eDET NORSKE VERITAS (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eLLOYDE'S REGISTER OF SHIPPIN (LRS)\u003c\/li\u003e\n\u003cli\u003eAMERICAN BUREAU OF SHIPPING (ABS)\u003c\/li\u003e\n\u003cli\u003eUL LISTED AS MARINE SHIPBOARD CABLE\u003c\/li\u003e\n\u003cli\u003eUNITED STATES COAST GUARD  \u003c\/li\u003e\n\u003cli\u003eCSA LISTED AS MARINE SHIPBOARD CABLE \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv style=\"position: absolute; left: -9px; top: 913.5px;\" id=\"gtx-trans\"\u003e\n\u003cdiv class=\"gtx-trans-icon\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Nassau National cable","offers":[{"title":"Default Title","offer_id":27521956053092,"sku":"NNC5005X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/five_type_p_479fb062-238e-430e-8d8f-9c7985bca138.png?v=1762459726"},{"product_id":"10-five-co-aaarmorp-shea-1k-600k","title":"10\/5 ARMORED CONTROL TYPE P DRILLING RIG MARINE POWER CABLE 600V \/ 1000Kv","description":"\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch2\u003e10\/5 Armored Control Type P Drilling Rig Marine Power Cable 600v \/ 1000kv\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity For 10-5 Armored Type P Drilling Rig Marine Power Cable 600V \/ 1000kV \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 38 Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e105ºC, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e33 Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e100ºC, 29 Amps at 90ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eType P Drilling Rig Marine Power Cable is an electrical cable designed for multipurpose use in offshore and onshore drilling and petroleum facilities. Typical applications include power, control, instrumentation, and communication. Type P cables demonstrate excellent capacity in demanding conditions, including extreme cold, heat, vibration, drilling, corrosion, and mechanical stress. The electrical cables are flame-retardant and resistant to moisture. They are armored with a \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003ebasket weave wire armor per IEEE 1580 and UL 1309\/CSA C22.2 No. 245\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e10\/5 Type P Rig Cable, 10\/5 Type P Cable, 10\/5 Type P Drilling Rig and Marine Cable, 10\/5 Rig Cable, 10\/5 Type P Polyrad Oil Gas XLPO, 10\/5 Type P Power Cable, 10\/5 Type P Unarmored, 10\/5 Type P Control Cable, 10\/5 Shipboard Cable\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Dual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Highest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Severe cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Flame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• NVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Transport Canada\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• DET Norske Veritas (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Llloyde's Register Of Shipping (LRS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• American Bureau Of Shipping (ABS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• UL Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• United States Coast Guard\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• CSA Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eConductor:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eHigh strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial cables.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eInsulation\/Jacket:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eFlame Retardant Cross-linked Polyolefin meets the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e• AWG Size: 10  \u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• MM2: 5.2 \u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Nominal Diameter (inches): 0.654\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Net Weight (Lbs\/1000 FT): 406\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e[\/short]\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFEATURES:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003eHigh strand count conductors make this product extremely flexible, \u003c\/span\u003e\u003cspan\u003eeasier to install and more resistant to vibration than Type MC, IEC \u003c\/span\u003e\u003cspan\u003espec or commercial cables.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eLower dielectric constant and higher insulation resistance reduces \u003c\/span\u003e\u003cspan\u003eelectrical losses.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eExcellent resistance to moisture produces stable electrical properties \u003c\/span\u003e\u003cspan\u003ethroughout the life of the cable.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIn fire conditions, non chlorinated flame retardant system produces. \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLess toxic and less corrosive gasses.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eDual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 \u003c\/span\u003e\u003cspan\u003eType X110.\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eHighest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, \u003c\/span\u003e\u003cspan\u003eTransport Canada 95°C\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSevere cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFlame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor uses all over the world it is designed and constructed for the demanding environments of offshore drilling and petroleum facilities. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCONDUCTOR:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eARMOR: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBasket weave wire armor per IEEE 1580 and UL 1309\/CSA C22.2 No. 245. Bronze standard. Tinned copper available by request.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eINSULATION\/JACKET: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFlame Retardant Cross-linked Polyolefin, meeting the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRATINGS \u0026amp; APPROVALS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eNVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eTRANSPORT CANADA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eDET NORSKE VERITAS (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eLLOYDE'S REGISTER OF SHIPPIN (LRS)\u003c\/li\u003e\n\u003cli\u003eAMERICAN BUREAU OF SHIPPING (ABS)\u003c\/li\u003e\n\u003cli\u003eUL LISTED AS MARINE SHIPBOARD CABLE\u003c\/li\u003e\n\u003cli\u003eUNITED STATES COAST GUARD  \u003c\/li\u003e\n\u003cli\u003eCSA LISTED AS MARINE SHIPBOARD CABLE \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e\n\u003cdiv style=\"position: absolute; left: -6px; top: 885.167px;\" id=\"gtx-trans\"\u003e\n\u003cdiv class=\"gtx-trans-icon\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cgdiv\u003e\u003c\/gdiv\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27521956937828,"sku":"NNC5014X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/61_0ec1d8c4-d013-4523-92eb-c32c3b354dd2.png?v=1762459731"},{"product_id":"1-0-five-co-aaarmorp-shea-1k-600k","title":"1\/0-5 ARMORED CONTROL TYPE P DRILLING RIG MARINE POWER CABLE 600V \/ 1000Kv","description":"\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch2\u003e1\/0-5 Armored Control Type P Drilling Rig Marine Power Cable 600v \/ 1000kv\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity For 1\/0-5 Armored Type P Drilling Rig Marine Power Cable 600V \/ 1000kV \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 140 Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e105ºC, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e131 Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e100ºC, 122 Amps at 90ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eType P Drilling Rig Marine Power Cable is an electrical cable designed for multipurpose use in offshore and onshore drilling and petroleum facilities. Typical applications include power, control, instrumentation, and communication. Type P cables demonstrate excellent capacity in demanding conditions, including extreme cold, heat, vibration, drilling, corrosion, and mechanical stress. The electrical cables are flame-retardant and resistant to moisture. They are armored with a \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003ebasket weave wire armor per IEEE 1580 and UL 1309\/CSA C22.2 No. 245\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e1\/0-5 Type P Rig Cable, 1\/0-5 Type P Cable, 1\/0-5 Type P Drilling Rig and Marine Cable, 1\/0-5 Rig Cable, 1\/0-5 Type P Polyrad Oil Gas XLPO, 1\/0-5 Type P Power Cable, 1\/0-5 Type P Unarmored, 1\/0-5 Type P Control Cable, 1\/0-5 Shipboard Cable\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Dual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Highest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Severe cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Flame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• NVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Transport Canada\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• DET Norske Veritas (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Llloyde's Register Of Shipping (LRS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• American Bureau Of Shipping (ABS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• UL Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• United States Coast Guard\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• CSA Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eConductor:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eHigh strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial cables.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eInsulation\/Jacket:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eFlame Retardant Cross-linked Polyolefin meets the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e• AWG Size: 1\/0   \u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• MM2: 54\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Nominal Diameter (inches): 1.668\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Net Weight (Lbs\/1000 FT): 2746\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFEATURES:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003eHigh strand count conductors make this product extremely flexible, \u003c\/span\u003e\u003cspan\u003eeasier to install and more resistant to vibration than Type MC, IEC \u003c\/span\u003e\u003cspan\u003espec or commercial cables.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eLower dielectric constant and higher insulation resistance reduces \u003c\/span\u003e\u003cspan\u003eelectrical losses.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eExcellent resistance to moisture produces stable electrical properties \u003c\/span\u003e\u003cspan\u003ethroughout the life of the cable.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIn fire conditions, non chlorinated flame retardant system produces. \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLess toxic and less corrosive gasses.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eDual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 \u003c\/span\u003e\u003cspan\u003eType X110.\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eHighest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, \u003c\/span\u003e\u003cspan\u003eTransport Canada 95°C\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSevere cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFlame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor uses all over the world it is designed and constructed for the demanding environments of offshore drilling and petroleum facilities. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCONDUCTOR:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eARMOR: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBasket weave wire armor per IEEE 1580 and UL 1309\/CSA C22.2 No. 245. Bronze standard. Tinned copper available by request.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eINSULATION\/JACKET: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFlame Retardant Cross-linked Polyolefin, meeting the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRATINGS \u0026amp; APPROVALS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eNVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eTRANSPORT CANADA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eDET NORSKE VERITAS (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eLLOYDE'S REGISTER OF SHIPPIN (LRS)\u003c\/li\u003e\n\u003cli\u003eAMERICAN BUREAU OF SHIPPING (ABS)\u003c\/li\u003e\n\u003cli\u003eUL LISTED AS MARINE SHIPBOARD CABLE\u003c\/li\u003e\n\u003cli\u003eUNITED STATES COAST GUARD  \u003c\/li\u003e\n\u003cli\u003eCSA LISTED AS MARINE SHIPBOARD CABLE \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e\n\u003cdiv style=\"position: absolute; left: -25px; top: 885.167px;\" id=\"gtx-trans\"\u003e\n\u003cdiv class=\"gtx-trans-icon\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cgdiv\u003e\u003c\/gdiv\u003e","brand":"Nassau National cable","offers":[{"title":"Default Title","offer_id":27521957363812,"sku":"NNC5020X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/61_1db11879-2391-4b7d-b4a7-9b578df56be0.png?v=1762459735"},{"product_id":"12-awg-20c-unarmored-type-p-drilling-rig-marine-control-cable-600v-1kv","title":"12 AWG 20C Unarmored Type P Drilling Rig \u0026 Marine Control Cable 600V\/1kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/dmc-06-type-p-control.pdf?v=1740491827\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 20C Unarmored Type P Drilling Rig \u0026amp; Marine Control Cable 600V\/1kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• DRILMAR 125-XE cables are specifically designed for the installation and use in marine environments, for use on offshore drilling rigs, aboard marine vessels, and on fixed and floating offshore facilities where harsh marine environments exist. These cables are used in control, indicating, communication, electronic and similar circuits where multiple conductor cables are required.\u003cbr\u003e• Typical applications include: Driller’s console, fire and gas detection systems, bilge and ballast controls and general alarm systems\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e12 AWG 20C Type P Rig Cable, Type P Cable, 12 AWG 20C Type P Drilling Rig and Marine Cable, Rig Cable, 12 AWG 20C Type P Power Cable, Shipboard Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• IEEE 1580\u003cbr\u003e• Recommended Practice for Marine Cable for Use on Shipboard and Fixed and Floating Platforms.\u003cbr\u003e• IEEE 45\u003cbr\u003e• Recommended Practice for Electrical Installations on Shipboard Cable.\u003cbr\u003e• UL 1309\u003cbr\u003e• Marine Shipboard Cable.\u003cbr\u003e• CSA C22.2 No. 245\u003cbr\u003e• Marine Shipboard Cable.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eEngineered for easiest installation. Extra flexible stranding meets IEEE, UL, and CSA requirements.\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003eMaximum conductor operating temperature: 100 °C as Type P per IEEE, and 110°C as Type X110 per UL and CSA. Meets ampacity ratings per ABS, DNV, LRS, and TCMS. \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003eDRILMAR XLPO Insulation:\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Superior oil and chemical resistance.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Sunlight resistant.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Rated at 125 ºC.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Passes Cold Bend at -55 ºC.\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003eHeavy Duty CP Jacket:\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Arctic Type XE design.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Abrasion and sunlight resistant.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Rated at 90 ºC.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Completed cable offers superior flame resistance meeting:\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• 70,000 Btu Flame Tests IEEE 1202\/FT4, IEEE 383, UL 1685, ICEA T-30-820, and IEC 332 Category A.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• 210,000 Btu Flame Test ICEA T-29-520.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Arctic Type design meets Cold Bend and Impact Tests at -40 ºC, exceeding the Transport Canada Marine Safety requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003c\/strong\u003e\u003cspan\u003e Soft annealed flexible Tin Coated Copper per IEEE, UL, and CSA.\u003cbr\u003e\u003cstrong\u003e• Separator Tape:\u003c\/strong\u003e Polyester tape as required.\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Insulation:\u003c\/strong\u003e\u003cspan\u003e Flame retardant and sunlight resistant Crosslinked Polyolefin (XLPO) per IEEE. Also meets and exceeds the requirements of UL and CSA for Type X110. DRILMAR 125-XE is a 125 °C XLPO.\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Identification:\u003c\/strong\u003e\u003cspan\u003e Color coded insulation per IEEE, UL and CSA. \u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003cstrong\u003e• Assembly: \u003c\/strong\u003eConductors cabled round with\u003cstrong\u003e \u003c\/strong\u003emoisture and flame retardant fillers, as required and binder tape.\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Jacket:\u003c\/strong\u003e\u003cspan\u003e Flame retardant and sunlight resistant Arctic Type Chlorinated Polyethylene (CPE) per IEEE, UL and CSA.\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Armor:\u003c\/strong\u003e\u003cspan\u003e Standard - Bronze.\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Overall Sheath (optional):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFlame retardant and sunlight resistant Arctic Type Chlorinated Polyethylene (CPE) per IEEE, UL, and CSA. \u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 12 AWG\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003cstrong\u003e• No. of Conductor:\u003c\/strong\u003e 20\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mils):\u003c\/strong\u003e 80\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mm):\u003c\/strong\u003e 2.13\u003cbr\u003e\u003cstrong\u003e• Nominal OD (in):\u003c\/strong\u003e 1.07\u003cbr\u003e\u003cstrong\u003e• Nominal OD (mm):\u003c\/strong\u003e 27.1\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e• Net Weight lb\/kft:\u003c\/strong\u003e 780\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cdiv style=\"position: absolute; left: -19px; top: 865.833px;\" id=\"gtx-trans\"\u003e\n\u003cdiv class=\"gtx-trans-icon\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27521960509540,"sku":"NNCDC12PCPE-20","price":9.68,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/6_1ba01281-6176-47ed-a89b-1f8d6cb8b647.png?v=1762459740"},{"product_id":"10-gauge-2-conductor-duplex-marine-cable-ul-1426-tinned-copper-wire","title":"10 GAUGE 2 CONDUCTOR DUPLEX MARINE CABLE UL 1426 TINNED COPPER WIRE","description":"\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch2\u003e\u003cb\u003e10 Gauge 2 Conductor Duplex Marine Cable Ul 1426 Tinned Copper Wire\u003c\/b\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eDuplex Marine Cable UL 1426 Tinned Copper Wire is specifically designed for all kinds of highly corrosive marine uses at high voltage. The electrical cable's tinned structure can also protect all types of vehicles from corrosion, making the cable perfect for use both on land and in water. The electrical cable's temperature rate is 105°C for dry applications and 75°C for moist applications. The voltage rating is 600 volts.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e Also Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eul 1426 wire, ul 1426 boat cable, Ancor marine grade duplex and triplex wire, duplex marine wire, marine grade wire, boat steering cable, shore power cable, boat cables, marine power cord, marine shore power cord, marine grade cable, marine steering cable, marine cord, marine electrical cable, boat control cables, marine power cable, marine control cables, marine shipboard cable, marine cable types, tinned copper wire marine, cable boat, marine shore power cable, anchor marine cable, tinned marine cable Us, marine wire cable, boat cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• UL 1426\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Coast Guard\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• DOT\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThere are two annealed tinned copper conductors available in several color combinations, including Black and red The tinned copper conductor is exceptionally flexible, making it easy to route through complex marine applications. Compared to bare copper, it is way easier to work with.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003ePVC insulation is resistant to water, oil, grease, gasoline, impact, abrasion, and weather. The insulation is conveniently flame-retardant.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e• Size: 10 Gauge\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Conductors: 2\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Number of Strands: 105\/30\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Jacket Color: White\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Jacket Material: Polyvinylchloride (PVC)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Voltage: 600 Volts\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Temp: Rated at 105°C (221°F) dry and 75°C (167°F) wet\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Outside Diameter: 0.273 x 0.466 inches\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Weight: 0.112 inches\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"100 FT \/ Flat","offer_id":39491989045402,"sku":"NNC13858X-1","price":112.0,"currency_code":"USD","in_stock":true},{"title":"100 FT \/ Round","offer_id":42502694731930,"sku":"","price":112.0,"currency_code":"USD","in_stock":true},{"title":"500 FT \/ Flat","offer_id":39491989078170,"sku":"NNC13858X-2","price":555.0,"currency_code":"USD","in_stock":true},{"title":"500 FT \/ Round","offer_id":42502694764698,"sku":"","price":555.0,"currency_code":"USD","in_stock":true},{"title":"1000 FT \/ Flat","offer_id":39491989110938,"sku":"NNC13858X-3","price":1110.0,"currency_code":"USD","in_stock":true},{"title":"1000 FT \/ Round","offer_id":42502694797466,"sku":"","price":1110.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/132_5eeb92e6-6229-475f-a8b0-c456b010dc6f.png?v=1762465786"},{"product_id":"10-gauge-3-conductor-triplex-marine-cable-ul-1426-tinned-copper-wire","title":"10 GAUGE 3 CONDUCTOR TRIPLEX MARINE CABLE UL 1426 TINNED COPPER WIRE","description":"\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch2\u003e\u003cb\u003e10 Gauge 3 Conductor Triplex Marine Cable Ul 1426 Tinned Copper Wire\u003c\/b\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eTriplex Marine Cable Ul 1426 Tinned Copper Wire is specifically designed for all kinds of highly corrosive marine uses at high voltage. The electrical cable's tinned structure can also protect all types of vehicles from corrosion, making the cable perfect for use both on land and in water. The electrical cable's temperature rate is 105°C for dry applications and 75°C for moist applications. The voltage rating is 600 volts.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e Also Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eUl 1426 wire, ul 1426 boat cable, Ancor marine grade duplex and triplex wire, triplex marine wire, marine grade wire, boat steering cable, shore power cable, boat cables, marine power cord, marine shore power cord, marine grade cable, marine steering cable, marine cord, marine electrical cable, boat control cables, marine power cable, marine control cables, marine shipboard cable, marine cable types, tinned copper wire marine, cable boat, marine shore power cable, anchor marine cable, tinned marine cable Us, marine wire cable, boat cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• UL 1426\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Coast Guard\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• DOT\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThere are three annealed tinned copper conductors in black, white, and green. The tinned copper conductor is exceptionally flexible, making it easy to route through complex marine applications. Compared to bare copper, it is way easier to work with.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003ePVC insulation is resistant to water, oil, grease, gasoline, impact, abrasion, and weather. The insulation is conveniently flame-retardant.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e• Size: 10 Gauge\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Conductors: 3\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Number of Strands: 105\/30\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Jacket Color: White\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e• Jacket Material: Polyvinylchloride (PVC)\u003c\/strong\u003e\u003cstrong\u003e • Voltage: 600 Volts\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Temp: Rated at 105°C (221°F) dry and 75°C (167°F) wet\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Outside Diameter: 0.273 x 0.659 inches\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Length: 100 ft or 500 ft \u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Weight: 19 lbs\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"100 FT","offer_id":39491744628890,"sku":"NNC13863X","price":176.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/133_200b8b01-ec37-4618-815f-62f8b2448b13.png?v=1762465789"},{"product_id":"1-awg-marine-battery-cable-ul-1426-tinned-copper-wire","title":"1 AWG MARINE BATTERY CABLE UL 1426 TINNED COPPER WIRE","description":"\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch2\u003e\u003cb\u003e1 AWG Marine Battery Cable UL 1424 Tinned Copper Wire\u003c\/b\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eMarine Battery Cable UL 1426 is specifically designed for all kinds of highly corrosive marine uses at high voltage. The electrical cable's tinned structure can also protect all types of vehicles from corrosion, making the cable perfect for land and water use. The electrical cable's temperature rate is 105°C for dry applications and 75°C for moist applications. The voltage rating is 600 volts. Due to its exceptional flexibility, this particular cable is used in batteries.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e Also Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e1 awg Ul 1426 wire, 1 awg ul 1426 boat cable, 1 awg marine wire, 1 awg anchor marine grade power wire, 1 awg anchor marine grade boat battery cable, 1 awg marine grade wire, 1 awg  boat steering cable, 1 awg shore power cable, 1 awg boat cables, 1 awg marine power cord, 1 awg marine shore power cord, 1 awg marine grade cable, 1 awg marine steering cable, 1 awg marine cord, 1 awg marine electrical cable, 1 awg boat control cables, 1 awg marine power cable, 1 awg marine control cables, 1 awg marine shipboard cable, 1 awg marine cable types, 1 awg tinned copper wire marine, 1 awg cable boat, 1 awg marine shore power cable, 1 awg anchor marine cable, 1 awg tinned marine cable US, 1 awg marine wire cable, 1 awg boat cable, 1 awg marine battery cable, 1 awg boat throttle cable, 1 awg boat battery cables, 1 awg marine push-pull cable, 1 awg marine grade battery cable, 1 awg tinned battery cable, 1 awg outboard battery cable, 1 awg ancor battery cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• UL 1426 for Boat Cable BC-5W2\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• DOT\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• US Coast Guard Charter boat (CFR Title 33, 44) \u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• ABYC \u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe annealed tinned copper conductors are exceptionally flexible, making it easy to route through complex marine applications. Compared to bare copper, it is way easier to work with.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eBlack PVC insulation is resistant to water, oil, grease, gasoline, impact, abrasion, and weather. The insulation is conveniently flame-retardant. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e• Size: 1 Gauge\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Number of Strands: 7 x 44\/30\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Voltage: 600 Volts\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Temp: Rated at 105°C (221°F) dry and 75 °C (167 °F) wet\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Outside Diameter: 0.520 inches\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Weight: 0.36 lbs per ft\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e\n\u003cgdiv\u003e\u003c\/gdiv\u003e","brand":"Nassau National Cable","offers":[{"title":"Black \/ 100 FT","offer_id":39492033675418,"sku":"NNC13867X-3","price":0.0,"currency_code":"USD","in_stock":true},{"title":"Red \/ 100 FT","offer_id":39492033708186,"sku":"NNC13867X-4","price":0.0,"currency_code":"USD","in_stock":true},{"title":"Yellow \/ 100 FT","offer_id":39492033740954,"sku":"NNC13867X-5","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/136_dad4565f-4b77-4ac8-a47b-78256e3a15ef.png?v=1759806603"},{"product_id":"1-0-awg-marine-battery-cable-ul-1426-tinned-copper-wire","title":"1\/0 AWG MARINE BATTERY CABLE UL 1426 TINNED COPPER WIRE","description":"\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch2\u003e\u003cb\u003e1\/0 AWG Marine Battery Cable UL 1424 Tinned Copper Wire\u003c\/b\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eMarine Battery Cable UL 1426 is specifically designed for all kinds of highly corrosive marine uses at high voltage. The electrical cable's tinned structure can also protect all types of vehicles from corrosion, making the cable perfect for land and water use. The electrical cable's temperature rate is 105°C for dry applications and 75°C for moist applications. The voltage rating is 600 volts. Due to its exceptional flexibility, this particular cable is used in batteries.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e Also Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e1\/0 awg Ul 1426 wire, 1\/0 awg ul 1426 boat cable, 1\/0 awg marine wire, 1\/0 awg anchor marine grade power wire, 1\/0 awg anchor marine grade boat battery cable, 1\/0 awg marine grade wire, 1\/0 awg  boat steering cable, 1\/0 awg shore power cable, 1\/0 awg boat cables, 1\/0 awg marine power cord, 1\/0 awg marine shore power cord, 1\/0 awg marine grade cable, 1\/0 awg marine steering cable, 1\/0 awg marine cord, 1\/0 awg marine electrical cable, 1\/0 awg boat control cables, 1\/0 awg marine power cable, 1\/0 awg marine control cables, 1\/0 awg marine shipboard cable, 1\/0 awg marine cable types, 1\/0 awg tinned copper wire marine, 1\/0 awg cable boat, 1\/0 awg marine shore power cable, 1\/0 awg anchor marine cable, 1\/0 awg tinned marine cable US, 1\/0 awg marine wire cable, 1\/0 awg boat cable, 1\/0 awg marine battery cable, 1\/0 awg boat throttle cable, 1\/0 awg boat battery cables, 1\/0 awg marine push-pull cable, 1\/0 awg marine grade battery cable, 1\/0 awg tinned battery cable, 1\/0 awg outboard battery cable, 1\/0 awg ancor battery cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• UL 1426 for Boat Cable BC-5W2\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• DOT\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• US Coast Guard Charter boat (CFR Title 33, 44) \u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• ABYC \u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe annealed tinned copper conductors are exceptionally flexible, making it easy to route through complex marine applications. Compared to bare copper, it is way easier to work with.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eBlack PVC insulation is resistant to water, oil, grease, gasoline, impact, abrasion, and weather. The insulation is conveniently flame-retardant. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e• Size: 1\/0 Gauge\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Number of Strands: 19 x 56\/30\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Voltage: 600 Volts\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Temp: Rated at 105°C (221°F) dry and 75 °C (167 °F) wet\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Jacket Material:Polyvinyl Chloride (PVC)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Outside Diameter: 0.565 inches\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Weight: 0.44 lbs per ft\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e\n\u003cgdiv\u003e\u003c\/gdiv\u003e","brand":"Nassau National Cable","offers":[{"title":"Black \/ 100 FT","offer_id":39492045176986,"sku":"NNC13868X-3","price":8.34,"currency_code":"USD","in_stock":true},{"title":"Red \/ 100 FT","offer_id":39492045209754,"sku":"NNC13868X-4","price":8.34,"currency_code":"USD","in_stock":true},{"title":"Yellow \/ 100 FT","offer_id":39492045242522,"sku":"NNC13868X-5","price":8.34,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/136_d2a19150-1365-4f3e-a684-19deeda6d3ed.png?v=1762465792"},{"product_id":"1-0-awg-anchor-marine-grade-boat-black-cable","title":"1\/0 AWG ANCHOR MARINE GRADE BOAT BLACK CABLE","description":"\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch2\u003e\u003cb\u003e1\/0 AWG Anchor Marine Grade Boat Black Cable\u003c\/b\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e Anchor Marine Grade Boat Black Cable is specifically designed for all kinds of highly corrosive marine uses at high voltage. The electrical cable's tinned structure can also protect all types of vehicles from corrosion, making the cable perfect for land and water use. The electrical cable's temperature rate is 105°C for dry applications and 75°C for moist applications. The voltage rating is 600 volts. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e Also Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e1\/0 AWG\u003c\/span\u003e \u003cspan style=\"font-weight: 400;\"\u003eUl 1426 wire, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e1\/0 AWG\u003c\/span\u003e \u003cspan style=\"font-weight: 400;\"\u003eul 1426 boat cable, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e1\/0 AWG \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003emarine wire, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e1\/0 AWG \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eanchor marine grade power wire, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e1\/0 AWG \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eanchor marine grade boat battery cable, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e1\/0 AWG \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003emarine grade wire, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e1\/0 AWG \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eboat steering cable, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e1\/0 AWG \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eshore power cable, boat cables, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e1\/0 AWG \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003emarine power cord, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e1\/0 AWG \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003emarine shore power cord, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e1\/0 AWG \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003emarine grade cable, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e1\/0 AWG \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003emarine steering cable, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e1\/0 AWG \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003emarine cord, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e1\/0 AWG \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003emarine electrical cable, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e1\/0 AWG \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eboat control cables, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e1\/0 AWG \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003emarine power cable, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e1\/0 AWG \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003emarine control cables, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e1\/0 AWG \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003emarine shipboard cable, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e1\/0 AWG \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003emarine cable types, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e1\/0 AWG \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003etinned copper wire marine, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e1\/0 AWG \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003ecable boat, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e1\/0 AWG \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003emarine shore power cable, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e1\/0 AWG \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eanchor marine cable, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e1\/0 AWG \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003etinned marine cable Us, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e1\/0 AWG \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003emarine wire cable, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e1\/0 AWG \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eboat cable, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e1\/0 AWG \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003emarine battery cable, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e1\/0 AWG \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eboat throttle cable, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e1\/0 AWG \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eboat battery cables, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e1\/0 AWG \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003emarine push-pull cable, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e1\/0 AWG \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003emarine grade battery cable, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e1\/0 AWG \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003etinned battery cable, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e1\/0 AWG \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eoutboard battery cable, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e1\/0 AWG \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eancor battery cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• UL 1426 for Boat Cable BC-5W2\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• DOT\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• US Coast Guard Charter boat (CFR Title 46) \u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• ABYC \u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eConductor: \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe annealed tinned copper conductors are exceptionally flexible, making it easy to easy route through complex marine applications. Compared to bare copper, it is way easier to work with.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eBlack PVC insulation is resistant to water, oil, grease, gasoline, impact, abrasion, and weather. The insulation is conveniently flame-retardant. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e• Size:1\/0\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Voltage: 600Volts\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Temp: Rated at 105°C (221°F) dry and 75 °C (167°F) wet\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Jacket Material:Polyvinylchloride (PVC)\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e\n\u003cgdiv\u003e\u003c\/gdiv\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27580584394852,"sku":"NNC13877X","price":7.78,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/134_c9779d4b-69d5-479d-8ec5-8b3ea3178d8b.png?v=1762465797"},{"product_id":"1-0-5-armored-sheathed-control-type-p-drilling-rig-marine-power-cable-600v-1000kv","title":"1\/0-5 ARMORED \u0026 SHEATHED CONTROL TYPE P DRILLING RIG MARINE POWER CABLE 600V \/ 1000Kv","description":"\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch2\u003e1\/0-5 Armored \u0026amp; Sheathed Type P Drilling Rig Marine Power Cable 600V \/ 1000kV\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity For 1\/0-5 Armored \u0026amp; Sheathed Type P Drilling Rig Marine Power Cable 600V \/ 1000kV \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 140 Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e105ºC, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e131 Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e100ºC, 122 Amps at 90ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eType P Drilling Rig Marine Power Cable is an electrical cable designed for multipurpose use in offshore and onshore drilling and petroleum facilities. Typical applications include power, control, instrumentation, and communication. Type P cables demonstrate excellent capacity in demanding conditions, including extreme cold, heat, vibration, drilling, corrosion, and mechanical stress. The electrical cables are flame-retardant and resistant to moisture. It is armored with a \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003ebasket weave wire armor per IEEE 1580 and UL 1309\/CSA C22.2 No. 245, and sheathed with a black, arctic grade, flame retardant, oil abrasion, chemical and sunlight resistant thermosetting compound meeting UL 1309 \/ CSA c22.2 No. 245 and IEEE 1580. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e1\/0-5 Type P Rig Cable, 1\/0-5 Type P Cable, 1\/0-5 Type P Drilling Rig and Marine Cable, 1\/0-5 Rig Cable, 1\/0-5 Type P Polyrad Oil Gas XLPO, 1\/0-5 Type P Power Cable, 1\/0-5 Type P Armored Sheathed, 1\/0-5 Type P Control Cable, 1\/0-5 Shipboard Cable\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Dual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Highest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Severe cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Flame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• NVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Transport Canada\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• DET Norske Veritas (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Llloyde's Register Of Shipping (LRS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• American Bureau Of Shipping (ABS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• UL Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• United States Coast Guard\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• CSA Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eConductor:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eHigh strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial cables.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eInsulation\/Jacket:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eFlame Retardant Cross-linked Polyolefin meets the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e• AWG Size: 1\/0\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• MM2: 54\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Nominal Diameter (inches): 1.903\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Net Weight (Lbs\/1000 FT): 3108\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFEATURES:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003eHigh strand count conductors make this product extremely flexible, \u003c\/span\u003e\u003cspan\u003eeasier to install and more resistant to vibration than Type MC, IEC \u003c\/span\u003e\u003cspan\u003espec or commercial cables.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eLower dielectric constant and higher insulation resistance reduces \u003c\/span\u003e\u003cspan\u003eelectrical losses.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eExcellent resistance to moisture produces stable electrical properties \u003c\/span\u003e\u003cspan\u003ethroughout the life of the cable.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIn fire conditions, non chlorinated flame retardant system produces. \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLess toxic and less corrosive gasses.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eDual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 \u003c\/span\u003e\u003cspan\u003eType X110.\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eHighest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, \u003c\/span\u003e\u003cspan\u003eTransport Canada 95°C\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSevere cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFlame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor uses all over the world it is designed and constructed for the demanding environments of offshore drilling and petroleum facilities. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCONDUCTOR:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eARMOR: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBasket weave wire armor per IEEE 1580 and UL 1309\/CSA C22.2 No. 245. Bronze standard. Tinned copper available by request.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSHEATH:000\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA black, arctic grade, flame retardant, oil abrasion, chemical and sunlight resistant thermosetting compound meeting UL 1309\/CSA C22.2 No. 245 and IEEE 1580.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eINSULATION\/JACKET: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFlame Retardant Cross-linked Polyolefin, meeting the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRATINGS \u0026amp; APPROVALS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eNVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eTRANSPORT CANADA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 12px;\"\u003eDET NORSKE VERITAS (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eLLOYDE'S REGISTER OF SHIPPIN (LRS)\u003c\/li\u003e\n\u003cli\u003eAMERICAN BUREAU OF SHIPPING (ABS)\u003c\/li\u003e\n\u003cli\u003eUL LISTED AS MARINE SHIPBOARD CABLE\u003c\/li\u003e\n\u003cli\u003eUNITED STATES COAST GUARD  \u003c\/li\u003e\n\u003cli\u003eCSA LISTED AS MARINE SHIPBOARD CABLE \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e\n\u003cdiv style=\"position: absolute; left: -8px; top: 990.833px;\" id=\"gtx-trans\"\u003e\n\u003cdiv class=\"gtx-trans-icon\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cgdiv\u003e\u003c\/gdiv\u003e","brand":"Nassau National cable","offers":[{"title":"Default Title","offer_id":27911959085156,"sku":"NNC33385X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/61_3923a813-2ac9-466e-8c5b-f5bde0ed5def.png?v=1762478216"},{"product_id":"1-core-1-5-mm-jis-c-3410-0-6-1kv-spyc-spycb-shipboard-flame-retardant-power-cable","title":"1 Core 1.5 mm² JIS C 3410 0.6\/1KV SPYC \/ SPYCB Shipboard Flame Retardant Power Cable","description":"[short]\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNo. of Cores :\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Nominal Area :\u003c\/strong\u003e 1.5 mm²\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Strand : \u003c\/strong\u003e7\/0.52  No.\/mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Dia. :\u003c\/strong\u003e 1.56 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eNominal Dia. Over Sheath :\u003c\/strong\u003e 5.9 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eSPYC \/ SPYCB Nominal Dia. :\u003c\/strong\u003e 7.2 \u003cspan data-mce-fragment=\"1\"\u003emm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eSPYC \/ SPYCB Tolerance :\u003c\/strong\u003e 0.4 ±mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Resistance (at 20°C) (Max):\u003c\/strong\u003e 12.2 Ω\/km\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eInsulation Resistance (at 20°C) (Min):\u003c\/strong\u003e 1,300 ㏁ - km\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCable Weight :\u003c\/strong\u003e 0.0706 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003e1 Core 1.5 mm² JIS C 3410 0.6\/1KV SPYC \/ SPYCB Shipboard Flame Retardant Power Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e for 1 Core 1.5 mm² JIS C 3410 0.6\/1KV SPYC \/ SPYCB Shipboard Flame Retardant Power Cable: 100 \u003cstrong\u003eAmps\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Design guide : JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• Flame retardant :  IEC60332-1\u003cbr\u003e                              :  IEC 60332-3 Category A (FA-Cables Only)\u003c\/li\u003e\n\u003cli\u003e• Cold bend\/impact : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Max. rated conductor temperature : 90℃\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, \u003cspan data-mce-fragment=\"1\"\u003eJIS C 3410 Cable, 0.6\/1KV SPYC, SPYCB Cable, Flame Retardant Cable, Power Cable, Tinned Annealed Copper\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Code\u003c\/strong\u003e : S\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e• Stranded tinned annealed copper wires as per JIS C 3410(2010)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e• A suitable tape may be applied on the conductor\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e\u003cbr\u003eInsulation :\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Code \u003c\/strong\u003e: P\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e• EPR as per JIS C 3410(2010)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003eCabling :\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Insulated conductors shall be cabled\u003c\/li\u003e\n\u003cli\u003e• Flame retardant \u0026amp; non-hygroscopic fillers may be used.\u003c\/li\u003e\n\u003cli\u003e• Suitable tape(s) may be applied on the cabled core.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSheath\u003c\/strong\u003e :\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC as per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eArmour\u003c\/strong\u003e :\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003e• Braid of galvanized steel wire(C) or copper alloy wire(CB)\u003c\/li\u003e\n\u003cli\u003e• Coverage density : Min. 90%\u003c\/li\u003e\n\u003cli\u003e• A suitable separator tape(s) may be applied under\/over the armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003ePaint\u003c\/strong\u003e :\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• The white paint shall be painted uniformly on the steel wire braid\u003c\/li\u003e\n\u003cli\u003e• In case of PVC protective covering cable, paint isdispensable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eProtective Covering\u003c\/strong\u003e :\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC as per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eProtective covering color\u003c\/strong\u003e : Black\u003c\/li\u003e\n\u003cli\u003e• Any other color may be applicable when purchaser required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39620176904346,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/FA-_SPYC_b80a32ef-670e-4559-a29b-1bdc26eebf2f.png?v=1762482711"},{"product_id":"1-core-2-5-mm-jis-c-3410-0-6-1kv-spyc-spycb-shipboard-flame-retardant-power-cable","title":"1 Core 2.5 mm² JIS C 3410 0.6\/1KV SPYC \/ SPYCB Shipboard Flame Retardant Power Cable","description":"[short]\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNo. of Cores :\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Nominal Area :\u003c\/strong\u003e 2.5 mm²\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Strand :\u003c\/strong\u003e 7\/0.67  No.\/mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Dia. :\u003c\/strong\u003e 2.01 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eNominal Dia. Over Sheath :\u003c\/strong\u003e 6.3 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eSPYC \/ SPYCB Nominal Dia. :\u003c\/strong\u003e 7.6 \u003cspan data-mce-fragment=\"1\"\u003emm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eSPYC \/ SPYCB Tolerance :\u003c\/strong\u003e 0.4 ±mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Resistance (at 20°C) (Max):\u003c\/strong\u003e 7.56 Ω\/km\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eInsulation Resistance (at 20°C) (Min):\u003c\/strong\u003e 1,100 ㏁ - km\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCable Weight :\u003c\/strong\u003e 0.0846 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003e1 Core 2.5 mm² JIS C 3410 0.6\/1KV SPYC \/ SPYCB Shipboard Flame Retardant Power Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e for 1 Core 2.5 mm² JIS C 3410 0.6\/1KV SPYC \/ SPYCB Shipboard Flame Retardant Power Cable: 100 \u003cstrong\u003eAmps\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Design guide : JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• Flame retardant :  IEC60332-1\u003cbr\u003e                              :  IEC 60332-3 Category A (FA-Cables Only)\u003c\/li\u003e\n\u003cli\u003e• Cold bend\/impact : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Max. rated conductor temperature : 90℃\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, \u003cspan data-mce-fragment=\"1\"\u003eJIS C 3410 Cable, 0.6\/1KV SPYC, SPYCB Cable, Flame Retardant Cable, Power Cable, Tinned Annealed Copper\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Code\u003c\/strong\u003e : S\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e• Stranded tinned annealed copper wires as per JIS C 3410(2010)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e• A suitable tape may be applied on the conductor\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e\u003cbr\u003eInsulation :\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Code \u003c\/strong\u003e: P\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e• EPR as per JIS C 3410(2010)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e\u003cbr\u003eCabling :\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Insulated conductors shall be cabled\u003c\/li\u003e\n\u003cli\u003e• Flame retardant \u0026amp; non-hygroscopic fillers may be used.\u003c\/li\u003e\n\u003cli\u003e• Suitable tape(s) may be applied on the cabled core.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSheath\u003c\/strong\u003e :\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC as per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eArmour\u003c\/strong\u003e :\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003e• Braid of galvanized steel wire(C) or copper alloy wire(CB)\u003c\/li\u003e\n\u003cli\u003e• Coverage density : Min. 90%\u003c\/li\u003e\n\u003cli\u003e• A suitable separator tape(s) may be applied under\/over the armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003ePaint\u003c\/strong\u003e :\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• The white paint shall be painted uniformly on the steel wire braid\u003c\/li\u003e\n\u003cli\u003e• In case of PVC protective covering cable, paint isdispensable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eProtective Covering\u003c\/strong\u003e :\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC as per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eProtective covering color\u003c\/strong\u003e : Black\u003c\/li\u003e\n\u003cli\u003e• Any other color may be applicable when purchaser required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39620190371994,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/FA-_SPYC_245035b7-aca2-4a0e-a0b1-7cd56ded7743.png?v=1762482711"},{"product_id":"1-core-4-mm-jis-c-3410-0-6-1kv-spyc-spycb-shipboard-flame-retardant-power-cable","title":"1 Core 4 mm² JIS C 3410 0.6\/1KV SPYC \/ SPYCB Shipboard Flame Retardant Power Cable","description":"[short]\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNo. of Cores :\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Nominal Area :\u003c\/strong\u003e 4 mm²\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Strand :\u003c\/strong\u003e 7\/0.85 No.\/mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Dia. :\u003c\/strong\u003e 2.55 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eNominal Dia. Over Sheath :\u003c\/strong\u003e 6.9 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eSPYC \/ SPYCB Nominal Dia. :\u003c\/strong\u003e 8.2 \u003cspan data-mce-fragment=\"1\"\u003emm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eSPYC \/ SPYCB Tolerance :\u003c\/strong\u003e 0.4 ±mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Resistance (at 20°C) (Max):\u003c\/strong\u003e 4.70 Ω\/km\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eInsulation Resistance (at 20°C) (Min):\u003c\/strong\u003e 1,000 ㏁ - km\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCable Weight :\u003c\/strong\u003e 0.0988 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003e1 Core 4 mm² JIS C 3410 0.6\/1KV SPYC \/ SPYCB Shipboard Flame Retardant Power Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e for 1 Core 4 mm² JIS C 3410 0.6\/1KV SPYC \/ SPYCB Shipboard Flame Retardant Power Cable: 100 \u003cstrong\u003eAmps\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Design guide : JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• Flame retardant :  IEC60332-1\u003cbr\u003e                              :  IEC 60332-3 Category A (FA-Cables Only)\u003c\/li\u003e\n\u003cli\u003e• Cold bend\/impact : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Max. rated conductor temperature : 90℃\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, \u003cspan data-mce-fragment=\"1\"\u003eJIS C 3410 Cable, 0.6\/1KV SPYC, SPYCB Cable, Flame Retardant Cable, Power Cable, Tinned Annealed Copper\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Code\u003c\/strong\u003e : S\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e• Stranded tinned annealed copper wires as per JIS C 3410(2010)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e• A suitable tape may be applied on the conductor\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e\u003cbr\u003eInsulation :\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Code \u003c\/strong\u003e: P\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e• EPR as per JIS C 3410(2010)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e\u003cbr\u003eCabling :\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Insulated conductors shall be cabled\u003c\/li\u003e\n\u003cli\u003e• Flame retardant \u0026amp; non-hygroscopic fillers may be used.\u003c\/li\u003e\n\u003cli\u003e• Suitable tape(s) may be applied on the cabled core.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSheath\u003c\/strong\u003e :\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC as per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eArmour\u003c\/strong\u003e :\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003e• Braid of galvanized steel wire(C) or copper alloy wire(CB)\u003c\/li\u003e\n\u003cli\u003e• Coverage density : Min. 90%\u003c\/li\u003e\n\u003cli\u003e• A suitable separator tape(s) may be applied under\/over the armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003ePaint\u003c\/strong\u003e :\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• The white paint shall be painted uniformly on the steel wire braid\u003c\/li\u003e\n\u003cli\u003e• In case of PVC protective covering cable, paint isdispensable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eProtective Covering\u003c\/strong\u003e :\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC as per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eProtective covering color\u003c\/strong\u003e : Black\u003c\/li\u003e\n\u003cli\u003e• Any other color may be applicable when purchaser required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39620199612570,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/FA-_SPYC_4fdae84f-87a8-4c2e-977f-ea0ff79cba36.png?v=1762482712"},{"product_id":"1-core-6-mm-jis-c-3410-0-6-1kv-spyc-spycb-shipboard-flame-retardant-power-cable","title":"1 Core 6 mm² JIS C 3410 0.6\/1KV SPYC \/ SPYCB Shipboard Flame Retardant Power Cable","description":"[short]\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNo. of Cores :\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Nominal Area :\u003c\/strong\u003e 6 mm²\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Strand :\u003c\/strong\u003e 7\/1.04 No.\/mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Dia. :\u003c\/strong\u003e 3.12 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eNominal Dia. Over Sheath :\u003c\/strong\u003e 7.4 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eSPYC \/ SPYCB Nominal Dia. :\u003c\/strong\u003e 8.7 \u003cspan data-mce-fragment=\"1\"\u003emm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eSPYC \/ SPYCB Tolerance :\u003c\/strong\u003e 0.4 ±mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Resistance (at 20°C) (Max):\u003c\/strong\u003e 3.11 Ω\/km\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eInsulation Resistance (at 20°C) (Min):\u003c\/strong\u003e 800 ㏁ - km\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCable Weight :\u003c\/strong\u003e 0.1199 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003e1 Core 6 mm² JIS C 3410 0.6\/1KV SPYC \/ SPYCB Shipboard Flame Retardant Power Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e for 1 Core 6 mm² JIS C 3410 0.6\/1KV SPYC \/ SPYCB Shipboard Flame Retardant Power Cable: 100 \u003cstrong\u003eAmps\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Design guide : JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• Flame retardant :  IEC60332-1\u003cbr\u003e                              :  IEC 60332-3 Category A (FA-Cables Only)\u003c\/li\u003e\n\u003cli\u003e• Cold bend\/impact : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Max. rated conductor temperature : 90℃\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, \u003cspan data-mce-fragment=\"1\"\u003eJIS C 3410 Cable, 0.6\/1KV SPYC, SPYCB Cable, Flame Retardant Cable, Power Cable, Tinned Annealed Copper\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Code\u003c\/strong\u003e : S\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e• Stranded tinned annealed copper wires as per JIS C 3410(2010)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e• A suitable tape may be applied on the conductor\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e\u003cbr\u003eInsulation :\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Code \u003c\/strong\u003e: P\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e• EPR as per JIS C 3410(2010)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e\u003cbr\u003eCabling :\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Insulated conductors shall be cabled\u003c\/li\u003e\n\u003cli\u003e• Flame retardant \u0026amp; non-hygroscopic fillers may be used.\u003c\/li\u003e\n\u003cli\u003e• Suitable tape(s) may be applied on the cabled core.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSheath\u003c\/strong\u003e :\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC as per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eArmour\u003c\/strong\u003e :\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003e• Braid of galvanized steel wire(C) or copper alloy wire(CB)\u003c\/li\u003e\n\u003cli\u003e• Coverage density : Min. 90%\u003c\/li\u003e\n\u003cli\u003e• A suitable separator tape(s) may be applied under\/over the armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003ePaint\u003c\/strong\u003e :\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• The white paint shall be painted uniformly on the steel wire braid\u003c\/li\u003e\n\u003cli\u003e• In case of PVC protective covering cable, paint isdispensable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eProtective Covering\u003c\/strong\u003e :\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC as per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eProtective covering color\u003c\/strong\u003e : Black\u003c\/li\u003e\n\u003cli\u003e• Any other color may be applicable when purchaser required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39620216324250,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/FA-_SPYC_3513862f-6d16-40ef-9c53-529a9ebdc528.png?v=1759812413"},{"product_id":"1-core-10-mm-jis-c-3410-0-6-1kv-spyc-spycb-shipboard-flame-retardant-power-cable","title":"1 Core 10 mm² JIS C 3410 0.6\/1KV SPYC \/ SPYCB Shipboard Flame Retardant Power Cable","description":"[short]\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNo. of Cores :\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Nominal Area :\u003c\/strong\u003e 10 mm²\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Strand :\u003c\/strong\u003e 7\/1.35 No.\/mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Dia. :\u003c\/strong\u003e 4.05 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eNominal Dia. Over Sheath :\u003c\/strong\u003e 8.6 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eSPYC \/ SPYCB Nominal Dia. :\u003c\/strong\u003e 9.9 \u003cspan data-mce-fragment=\"1\"\u003emm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eSPYC \/ SPYCB Tolerance :\u003c\/strong\u003e 0.4 ±mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Resistance (at 20°C) (Max):\u003c\/strong\u003e 1.84 Ω\/km\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eInsulation Resistance (at 20°C) (Min):\u003c\/strong\u003e 700 ㏁ - km\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCable Weight :\u003c\/strong\u003e 0.1588 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003e1 Core 10 mm² JIS C 3410 0.6\/1KV SPYC \/ SPYCB Shipboard Flame Retardant Power Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e for 1 Core 10 mm² JIS C 3410 0.6\/1KV SPYC \/ SPYCB Shipboard Flame Retardant Power Cable: 100 \u003cstrong\u003eAmps\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Design guide : JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• Flame retardant :  IEC60332-1\u003cbr\u003e                              :  IEC 60332-3 Category A (FA-Cables Only)\u003c\/li\u003e\n\u003cli\u003e• Cold bend\/impact : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Max. rated conductor temperature : 90℃\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, \u003cspan data-mce-fragment=\"1\"\u003eJIS C 3410 Cable, 0.6\/1KV SPYC, SPYCB Cable, Flame Retardant Cable, Power Cable, Tinned Annealed Copper\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Code\u003c\/strong\u003e : S\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e• Stranded tinned annealed copper wires as per JIS C 3410(2010)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e• A suitable tape may be applied on the conductor\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e\u003cbr\u003eInsulation :\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Code \u003c\/strong\u003e: P\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e• EPR as per JIS C 3410(2010)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e\u003cbr\u003eCabling :\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Insulated conductors shall be cabled\u003c\/li\u003e\n\u003cli\u003e• Flame retardant \u0026amp; non-hygroscopic fillers may be used.\u003c\/li\u003e\n\u003cli\u003e• Suitable tape(s) may be applied on the cabled core.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSheath\u003c\/strong\u003e :\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC as per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eArmour\u003c\/strong\u003e :\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003e• Braid of galvanized steel wire(C) or copper alloy wire(CB)\u003c\/li\u003e\n\u003cli\u003e• Coverage density : Min. 90%\u003c\/li\u003e\n\u003cli\u003e• A suitable separator tape(s) may be applied under\/over the armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003ePaint\u003c\/strong\u003e :\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• The white paint shall be painted uniformly on the steel wire braid\u003c\/li\u003e\n\u003cli\u003e• In case of PVC protective covering cable, paint isdispensable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eProtective Covering\u003c\/strong\u003e :\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC as per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eProtective covering color\u003c\/strong\u003e : Black\u003c\/li\u003e\n\u003cli\u003e• Any other color may be applicable when purchaser required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39620225106074,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/FA-_SPYC_c12fa1b7-f7f5-4e27-aaa3-009695cb3e98.png?v=1762482713"},{"product_id":"1-core-16-mm-jis-c-3410-0-6-1kv-spyc-spycb-shipboard-flame-retardant-power-cable","title":"1 Core 16 mm² JIS C 3410 0.6\/1KV SPYC \/ SPYCB Shipboard Flame Retardant Power Cable","description":"[short]\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNo. of Cores :\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Nominal Area :\u003c\/strong\u003e 16 mm²\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Strand :\u003c\/strong\u003e 7\/1.70 No.\/mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Dia. :\u003c\/strong\u003e 5.10 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eNominal Dia. Over Sheath :\u003c\/strong\u003e 9.6 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eSPYC \/ SPYCB Nominal Dia. :\u003c\/strong\u003e 10.9 \u003cspan data-mce-fragment=\"1\"\u003emm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eSPYC \/ SPYCB Tolerance :\u003c\/strong\u003e 0.4 ±mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Resistance (at 20°C) (Max):\u003c\/strong\u003e 1.16 Ω\/km\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eInsulation Resistance (at 20°C) (Min):\u003c\/strong\u003e 600 ㏁ - km\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCable Weight :\u003c\/strong\u003e 0.2117 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003e1 Core 16 mm² JIS C 3410 0.6\/1KV SPYC \/ SPYCB Shipboard Flame Retardant Power Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e for 1 Core 16 mm² JIS C 3410 0.6\/1KV SPYC \/ SPYCB Shipboard Flame Retardant Power Cable: 100 \u003cstrong\u003eAmps\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Design guide : JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• Flame retardant :  IEC60332-1\u003cbr\u003e                              :  IEC 60332-3 Category A (FA-Cables Only)\u003c\/li\u003e\n\u003cli\u003e• Cold bend\/impact : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Max. rated conductor temperature : 90℃\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, \u003cspan data-mce-fragment=\"1\"\u003eJIS C 3410 Cable, 0.6\/1KV SPYC, SPYCB Cable, Flame Retardant Cable, Power Cable, Tinned Annealed Copper\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Code\u003c\/strong\u003e : S\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e• Stranded tinned annealed copper wires as per JIS C 3410(2010)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e• A suitable tape may be applied on the conductor\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e\u003cbr\u003eInsulation :\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Code \u003c\/strong\u003e: P\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e• EPR as per JIS C 3410(2010)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e\u003cbr\u003eCabling :\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Insulated conductors shall be cabled\u003c\/li\u003e\n\u003cli\u003e• Flame retardant \u0026amp; non-hygroscopic fillers may be used.\u003c\/li\u003e\n\u003cli\u003e• Suitable tape(s) may be applied on the cabled core.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSheath\u003c\/strong\u003e :\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC as per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eArmour\u003c\/strong\u003e :\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003e• Braid of galvanized steel wire(C) or copper alloy wire(CB)\u003c\/li\u003e\n\u003cli\u003e• Coverage density : Min. 90%\u003c\/li\u003e\n\u003cli\u003e• A suitable separator tape(s) may be applied under\/over the armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003ePaint\u003c\/strong\u003e :\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• The white paint shall be painted uniformly on the steel wire braid\u003c\/li\u003e\n\u003cli\u003e• In case of PVC protective covering cable, paint isdispensable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eProtective Covering\u003c\/strong\u003e :\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC as per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eProtective covering color\u003c\/strong\u003e : Black\u003c\/li\u003e\n\u003cli\u003e• Any other color may be applicable when purchaser required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39620231561370,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/FA-_SPYC_9edf1b45-8864-4b43-9793-50e58109702c.png?v=1762482713"},{"product_id":"1-core-25-mm-jis-c-3410-0-6-1kv-spyc-spycb-shipboard-flame-retardant-power-cable","title":"1 Core 25 mm² JIS C 3410 0.6\/1KV SPYC \/ SPYCB Shipboard Flame Retardant Power Cable","description":"[short]\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNo. of Cores :\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Nominal Area :\u003c\/strong\u003e 25 mm²\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Strand :\u003c\/strong\u003e 7\/2.14 No.\/mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Dia. :\u003c\/strong\u003e 6.42 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eNominal Dia. Over Sheath :\u003c\/strong\u003e 11.5 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eSPYC \/ SPYCB Nominal Dia. :\u003c\/strong\u003e 12.8 \u003cspan data-mce-fragment=\"1\"\u003emm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eSPYC \/ SPYCB Tolerance :\u003c\/strong\u003e 0.5 ±mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Resistance (at 20°C) (Max):\u003c\/strong\u003e 0.734 Ω\/km\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eInsulation Resistance (at 20°C) (Min):\u003c\/strong\u003e 500 ㏁ - km\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCable Weight :\u003c\/strong\u003e 0.2999 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003e1 Core 25 mm² JIS C 3410 0.6\/1KV SPYC \/ SPYCB Shipboard Flame Retardant Power Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e for 1 Core 25 mm² JIS C 3410 0.6\/1KV SPYC \/ SPYCB Shipboard Flame Retardant Power Cable: 100 \u003cstrong\u003eAmps\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Design guide : JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• Flame retardant :  IEC60332-1\u003cbr\u003e                              :  IEC 60332-3 Category A (FA-Cables Only)\u003c\/li\u003e\n\u003cli\u003e• Cold bend\/impact : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Max. rated conductor temperature : 90℃\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, \u003cspan data-mce-fragment=\"1\"\u003eJIS C 3410 Cable, 0.6\/1KV SPYC, SPYCB Cable, Flame Retardant Cable, Power Cable, Tinned Annealed Copper\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Code\u003c\/strong\u003e : S\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e• Stranded tinned annealed copper wires as per JIS C 3410(2010)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e• A suitable tape may be applied on the conductor\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e\u003cbr\u003eInsulation :\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Code \u003c\/strong\u003e: P\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e• EPR as per JIS C 3410(2010)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e\u003cbr\u003eCabling :\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Insulated conductors shall be cabled\u003c\/li\u003e\n\u003cli\u003e• Flame retardant \u0026amp; non-hygroscopic fillers may be used.\u003c\/li\u003e\n\u003cli\u003e• Suitable tape(s) may be applied on the cabled core.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSheath\u003c\/strong\u003e :\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC as per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eArmour\u003c\/strong\u003e :\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003e• Braid of galvanized steel wire(C) or copper alloy wire(CB)\u003c\/li\u003e\n\u003cli\u003e• Coverage density : Min. 90%\u003c\/li\u003e\n\u003cli\u003e• A suitable separator tape(s) may be applied under\/over the armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003ePaint\u003c\/strong\u003e :\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• The white paint shall be painted uniformly on the steel wire braid\u003c\/li\u003e\n\u003cli\u003e• In case of PVC protective covering cable, paint isdispensable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eProtective Covering\u003c\/strong\u003e :\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC as per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eProtective covering color\u003c\/strong\u003e : Black\u003c\/li\u003e\n\u003cli\u003e• Any other color may be applicable when purchaser required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39620240310426,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/FA-_SPYC_cddf4d49-0114-4567-8eb3-70575b70b138.png?v=1762482715"},{"product_id":"1-core-35-mm-jis-c-3410-0-6-1kv-spyc-spycb-shipboard-flame-retardant-power-cable","title":"1 Core 35 mm² JIS C 3410 0.6\/1KV SPYC \/ SPYCB Shipboard Flame Retardant Power Cable","description":"[short]\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNo. of Cores :\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Nominal Area :\u003c\/strong\u003e 35 mm²\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Strand :\u003c\/strong\u003e 7\/2.52 No.\/mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Dia. :\u003c\/strong\u003e 7.56 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e• Nominal Dia. Over Sheath :\u003c\/strong\u003e 12.7 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eSPYC \/ SPYCB Nominal Dia. :\u003c\/strong\u003e 14.0 \u003cspan data-mce-fragment=\"1\"\u003emm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e• • \u003cstrong\u003eSPYC \/ SPYCB Tolerance :\u003c\/strong\u003e 0.6 ±mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Resistance (at 20°C) (Max):\u003c\/strong\u003e 0.529 Ω\/km\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eInsulation Resistance (at 20°C) (Min):\u003c\/strong\u003e 450 ㏁ - km\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e• Cable Weight :\u003c\/strong\u003e 0.3775 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003e1 Core 35 mm² JIS C 3410 0.6\/1KV SPYC \/ SPYCB Shipboard Flame Retardant Power Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e for 1 Core 35 mm² JIS C 3410 0.6\/1KV SPYC \/ SPYCB Shipboard Flame Retardant Power Cable: 100 \u003cstrong\u003eAmps\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Design guide : JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• Flame retardant :  IEC60332-1\u003cbr\u003e                              :  IEC 60332-3 Category A (FA-Cables Only)\u003c\/li\u003e\n\u003cli\u003e• Cold bend\/impact : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Max. rated conductor temperature : 90℃\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, \u003cspan data-mce-fragment=\"1\"\u003eJIS C 3410 Cable, 0.6\/1KV SPYC, SPYCB Cable, Flame Retardant Cable, Power Cable, Tinned Annealed Copper\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Code\u003c\/strong\u003e : S\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e• Stranded tinned annealed copper wires as per JIS C 3410(2010)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e• A suitable tape may be applied on the conductor\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e\u003cbr\u003eInsulation :\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Code \u003c\/strong\u003e: P\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e• EPR as per JIS C 3410(2010)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e\u003cbr\u003eCabling :\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Insulated conductors shall be cabled\u003c\/li\u003e\n\u003cli\u003e• Flame retardant \u0026amp; non-hygroscopic fillers may be used.\u003c\/li\u003e\n\u003cli\u003e• Suitable tape(s) may be applied on the cabled core.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSheath\u003c\/strong\u003e :\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC as per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eArmour\u003c\/strong\u003e :\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003e• Braid of galvanized steel wire(C) or copper alloy wire(CB)\u003c\/li\u003e\n\u003cli\u003e• Coverage density : Min. 90%\u003c\/li\u003e\n\u003cli\u003e• A suitable separator tape(s) may be applied under\/over the armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003ePaint\u003c\/strong\u003e :\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• The white paint shall be painted uniformly on the steel wire braid\u003c\/li\u003e\n\u003cli\u003e• In case of PVC protective covering cable, paint isdispensable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eProtective Covering\u003c\/strong\u003e :\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC as per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eProtective covering color\u003c\/strong\u003e : Black\u003c\/li\u003e\n\u003cli\u003e• Any other color may be applicable when purchaser required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39620255842458,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/FA-_SPYC_5c38af5b-5285-457e-9d74-6c99d4f1953d.png?v=1762482715"},{"product_id":"1-core-50-mm-jis-c-3410-0-6-1kv-spyc-spycb-shipboard-flame-retardant-power-cable","title":"1 Core 50 mm² JIS C 3410 0.6\/1KV SPYC \/ SPYCB Shipboard Flame Retardant Power Cable","description":"[short]\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNo. of Cores :\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Nominal Area :\u003c\/strong\u003e 50 mm²\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Strand :\u003c\/strong\u003e 19\/1.78 No.\/mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Dia. :\u003c\/strong\u003e 8.90 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eNominal Dia. Over Sheath :\u003c\/strong\u003e 14.6 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eSPYC \/ SPYCB Nominal Dia. :\u003c\/strong\u003e 15.9 \u003cspan data-mce-fragment=\"1\"\u003emm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eSPYC \/ SPYCB Tolerance :\u003c\/strong\u003e 0.6 ±mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Resistance (at 20°C) (Max):\u003c\/strong\u003e 0.391 Ω\/km\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eInsulation Resistance (at 20°C) (Min):\u003c\/strong\u003e 450 ㏁ - km\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCable Weight :\u003c\/strong\u003e 0.4939 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003e1 Core 50 mm² JIS C 3410 0.6\/1KV SPYC \/ SPYCB Shipboard Flame Retardant Power Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e for 1 Core 50 mm² JIS C 3410 0.6\/1KV SPYC \/ SPYCB Shipboard Flame Retardant Power Cable: 100 \u003cstrong\u003eAmps\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Design guide : JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• Flame retardant :  IEC60332-1\u003cbr\u003e                              :  IEC 60332-3 Category A (FA-Cables Only)\u003c\/li\u003e\n\u003cli\u003e• Cold bend\/impact : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Max. rated conductor temperature : 90℃\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, \u003cspan data-mce-fragment=\"1\"\u003eJIS C 3410 Cable, 0.6\/1KV SPYC, SPYCB Cable, Flame Retardant Cable, Power Cable, Tinned Annealed Copper\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Code\u003c\/strong\u003e : S\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e• Stranded tinned annealed copper wires as per JIS C 3410(2010)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e• A suitable tape may be applied on the conductor\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e\u003cbr\u003eInsulation :\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Code \u003c\/strong\u003e: P\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e• EPR as per JIS C 3410(2010)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e\u003cbr\u003eCabling :\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Insulated conductors shall be cabled\u003c\/li\u003e\n\u003cli\u003e• Flame retardant \u0026amp; non-hygroscopic fillers may be used.\u003c\/li\u003e\n\u003cli\u003e• Suitable tape(s) may be applied on the cabled core.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSheath\u003c\/strong\u003e :\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC as per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eArmour\u003c\/strong\u003e :\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003e• Braid of galvanized steel wire(C) or copper alloy wire(CB)\u003c\/li\u003e\n\u003cli\u003e• Coverage density : Min. 90%\u003c\/li\u003e\n\u003cli\u003e• A suitable separator tape(s) may be applied under\/over the armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003ePaint\u003c\/strong\u003e :\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• The white paint shall be painted uniformly on the steel wire braid\u003c\/li\u003e\n\u003cli\u003e• In case of PVC protective covering cable, paint isdispensable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eProtective Covering\u003c\/strong\u003e :\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC as per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eProtective covering color\u003c\/strong\u003e : Black\u003c\/li\u003e\n\u003cli\u003e• Any other color may be applicable when purchaser required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39620283728026,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/FA-_SPYC_a644c178-7ef6-43bd-b30e-8fd940d58576.png?v=1762482716"},{"product_id":"1-core-70-mm-jis-c-3410-0-6-1kv-spyc-spycb-shipboard-flame-retardant-power-cable","title":"1 Core 70 mm² JIS C 3410 0.6\/1KV SPYC \/ SPYCB Shipboard Flame Retardant Power Cable","description":"[short]\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNo. of Cores :\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Nominal Area :\u003c\/strong\u003e 70 mm²\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Strand :\u003c\/strong\u003e 19\/2.14 No.\/mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Dia. :\u003c\/strong\u003e 10.70 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eNominal Dia. Over Sheath :\u003c\/strong\u003e 16.6 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eSPYC \/ SPYCB Nominal Dia. :\u003c\/strong\u003e 17.9 \u003cspan data-mce-fragment=\"1\"\u003emm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eSPYC \/ SPYCB Tolerance :\u003c\/strong\u003e 0.7 ±mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Resistance (at 20°C) (Max):\u003c\/strong\u003e 0.270 Ω\/km\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eInsulation Resistance (at 20°C) (Min):\u003c\/strong\u003e 450 ㏁ - km\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCable Weight :\u003c\/strong\u003e 0.6633 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003e1 Core 70 mm² JIS C 3410 0.6\/1KV SPYC \/ SPYCB Shipboard Flame Retardant Power Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e for 1 Core 70 mm² JIS C 3410 0.6\/1KV SPYC \/ SPYCB Shipboard Flame Retardant Power Cable: 100 \u003cstrong\u003eAmps\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Design guide : JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• Flame retardant :  IEC60332-1\u003cbr\u003e                              :  IEC 60332-3 Category A (FA-Cables Only)\u003c\/li\u003e\n\u003cli\u003e• Cold bend\/impact : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Max. rated conductor temperature : 90℃\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, \u003cspan data-mce-fragment=\"1\"\u003eJIS C 3410 Cable, 0.6\/1KV SPYC, SPYCB Cable, Flame Retardant Cable, Power Cable, Tinned Annealed Copper\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Code\u003c\/strong\u003e : S\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e• Stranded tinned annealed copper wires as per JIS C 3410(2010)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e• A suitable tape may be applied on the conductor\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e\u003cbr\u003eInsulation :\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Code \u003c\/strong\u003e: P\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e• EPR as per JIS C 3410(2010)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e\u003cbr\u003eCabling :\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Insulated conductors shall be cabled\u003c\/li\u003e\n\u003cli\u003e• Flame retardant \u0026amp; non-hygroscopic fillers may be used.\u003c\/li\u003e\n\u003cli\u003e• Suitable tape(s) may be applied on the cabled core.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSheath\u003c\/strong\u003e :\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC as per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eArmour\u003c\/strong\u003e :\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003e• Braid of galvanized steel wire(C) or copper alloy wire(CB)\u003c\/li\u003e\n\u003cli\u003e• Coverage density : Min. 90%\u003c\/li\u003e\n\u003cli\u003e• A suitable separator tape(s) may be applied under\/over the armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003ePaint\u003c\/strong\u003e :\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• The white paint shall be painted uniformly on the steel wire braid\u003c\/li\u003e\n\u003cli\u003e• In case of PVC protective covering cable, paint isdispensable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eProtective Covering\u003c\/strong\u003e :\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC as per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eProtective covering color\u003c\/strong\u003e : Black\u003c\/li\u003e\n\u003cli\u003e• Any other color may be applicable when purchaser required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39620310859930,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/FA-_SPYC_7c283d7c-64ee-4032-9672-8c17734186fb.png?v=1762482718"},{"product_id":"1-core-95-mm-jis-c-3410-0-6-1kv-spyc-spycb-shipboard-flame-retardant-power-cable","title":"1 Core 95 mm² JIS C 3410 0.6\/1KV SPYC \/ SPYCB Shipboard Flame Retardant Power Cable","description":"[short]\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNo. of Cores :\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Nominal Area :\u003c\/strong\u003e 95 mm²\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Strand :\u003c\/strong\u003e 19\/2.52 No.\/mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Dia. :\u003c\/strong\u003e 12.60 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eNominal Dia. Over Sheath :\u003c\/strong\u003e 19.3 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eSPYC \/ SPYCB Nominal Dia. :\u003c\/strong\u003e 20.6 \u003cspan data-mce-fragment=\"1\"\u003emm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eSPYC \/ SPYCB Tolerance :\u003c\/strong\u003e 0.8 ±mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Resistance (at 20°C) (Max):\u003c\/strong\u003e 0.195 Ω\/km\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eInsulation Resistance (at 20°C) (Min):\u003c\/strong\u003e 400 ㏁ - km\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCable Weight :\u003c\/strong\u003e 0.8890 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003e1 Core 95 mm² JIS C 3410 0.6\/1KV SPYC \/ SPYCB Shipboard Flame Retardant Power Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e for 1 Core 95 mm² JIS C 3410 0.6\/1KV SPYC \/ SPYCB Shipboard Flame Retardant Power Cable: 100 \u003cstrong\u003eAmps\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Design guide : JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• Flame retardant :  IEC60332-1\u003cbr\u003e                              :  IEC 60332-3 Category A (FA-Cables Only)\u003c\/li\u003e\n\u003cli\u003e• Cold bend\/impact : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Max. rated conductor temperature : 90℃\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, \u003cspan data-mce-fragment=\"1\"\u003eJIS C 3410 Cable, 0.6\/1KV SPYC, SPYCB Cable, Flame Retardant Cable, Power Cable, Tinned Annealed Copper\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Code\u003c\/strong\u003e : S\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e• Stranded tinned annealed copper wires as per JIS C 3410(2010)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e• A suitable tape may be applied on the conductor\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e\u003cbr\u003eInsulation :\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Code \u003c\/strong\u003e: P\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e• EPR as per JIS C 3410(2010)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e\u003cbr\u003eCabling :\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Insulated conductors shall be cabled\u003c\/li\u003e\n\u003cli\u003e• Flame retardant \u0026amp; non-hygroscopic fillers may be used.\u003c\/li\u003e\n\u003cli\u003e• Suitable tape(s) may be applied on the cabled core.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSheath\u003c\/strong\u003e :\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC as per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eArmour\u003c\/strong\u003e :\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003e• Braid of galvanized steel wire(C) or copper alloy wire(CB)\u003c\/li\u003e\n\u003cli\u003e• Coverage density : Min. 90%\u003c\/li\u003e\n\u003cli\u003e• A suitable separator tape(s) may be applied under\/over the armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003ePaint\u003c\/strong\u003e :\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• The white paint shall be painted uniformly on the steel wire braid\u003c\/li\u003e\n\u003cli\u003e• In case of PVC protective covering cable, paint isdispensable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eProtective Covering\u003c\/strong\u003e :\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC as per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eProtective covering color\u003c\/strong\u003e : Black\u003c\/li\u003e\n\u003cli\u003e• Any other color may be applicable when purchaser required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39620323246234,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/FA-_SPYC_1ce1127e-7649-4e94-b50e-aaefdaf90080.png?v=1762482719"},{"product_id":"1-core-120-mm-jis-c-3410-0-6-1kv-spyc-spycb-shipboard-flame-retardant-power-cable","title":"1 Core 120 mm² JIS C 3410 0.6\/1KV SPYC \/ SPYCB Shipboard Flame Retardant Power Cable","description":"[short]\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNo. of Cores :\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Nominal Area :\u003c\/strong\u003e 120 mm²\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Strand :\u003c\/strong\u003e 37\/2.03 No.\/mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Dia. :\u003c\/strong\u003e 14.20 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eNominal Dia. Over Sheath :\u003c\/strong\u003e 20.9 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eSPYC \/ SPYCB Nominal Dia. :\u003c\/strong\u003e 22.2 \u003cspan data-mce-fragment=\"1\"\u003emm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eSPYC \/ SPYCB Tolerance :\u003c\/strong\u003e 0.9 ±mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Resistance (at 20°C) (Max):\u003c\/strong\u003e 0.154 Ω\/km\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eInsulation Resistance (at 20°C) (Min):\u003c\/strong\u003e 350 ㏁ - km\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCable Weight :\u003c\/strong\u003e 1.0725 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003e1 Core 120 mm² JIS C 3410 0.6\/1KV SPYC \/ SPYCB Shipboard Flame Retardant Power Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e for 1 Core 120 mm² JIS C 3410 0.6\/1KV SPYC \/ SPYCB Shipboard Flame Retardant Power Cable: 100 \u003cstrong\u003eAmps\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Design guide : JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• Flame retardant :  IEC60332-1\u003cbr\u003e                              :  IEC 60332-3 Category A (FA-Cables Only)\u003c\/li\u003e\n\u003cli\u003e• Cold bend\/impact : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Max. rated conductor temperature : 90℃\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, \u003cspan data-mce-fragment=\"1\"\u003eJIS C 3410 Cable, 0.6\/1KV SPYC, SPYCB Cable, Flame Retardant Cable, Power Cable, Tinned Annealed Copper\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Code\u003c\/strong\u003e : S\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e• Stranded tinned annealed copper wires as per JIS C 3410(2010)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e• A suitable tape may be applied on the conductor\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e\u003cbr\u003eInsulation :\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Code \u003c\/strong\u003e: P\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e• EPR as per JIS C 3410(2010)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e\u003cbr\u003eCabling :\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Insulated conductors shall be cabled\u003c\/li\u003e\n\u003cli\u003e• Flame retardant \u0026amp; non-hygroscopic fillers may be used.\u003c\/li\u003e\n\u003cli\u003e• Suitable tape(s) may be applied on the cabled core.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSheath\u003c\/strong\u003e :\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC as per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eArmour\u003c\/strong\u003e :\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003e• Braid of galvanized steel wire(C) or copper alloy wire(CB)\u003c\/li\u003e\n\u003cli\u003e• Coverage density : Min. 90%\u003c\/li\u003e\n\u003cli\u003e• A suitable separator tape(s) may be applied under\/over the armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003ePaint\u003c\/strong\u003e :\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• The white paint shall be painted uniformly on the steel wire braid\u003c\/li\u003e\n\u003cli\u003e• In case of PVC protective covering cable, paint isdispensable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eProtective Covering\u003c\/strong\u003e :\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC as per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eProtective covering color\u003c\/strong\u003e : Black\u003c\/li\u003e\n\u003cli\u003e• Any other color may be applicable when purchaser required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39626576560282,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/FA-_SPYC_4ea456eb-3df8-46dd-9c4e-991c4517c782.png?v=1762482727"},{"product_id":"1-core-150-mm-jis-c-3410-0-6-1kv-spyc-spycb-shipboard-flame-retardant-power-cable","title":"1 Core 150 mm² JIS C 3410 0.6\/1KV SPYC \/ SPYCB Shipboard Flame Retardant Power Cable","description":"[short]\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNo. of Cores :\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Nominal Area :\u003c\/strong\u003e 150 mm²\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Strand :\u003c\/strong\u003e 37\/2.25 No.\/mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Dia. :\u003c\/strong\u003e 15.80 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eNominal Dia. Over Sheath :\u003c\/strong\u003e 23.1 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eSPYC \/ SPYCB Nominal Dia. :\u003c\/strong\u003e 24.4 \u003cspan data-mce-fragment=\"1\"\u003emm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eSPYC \/ SPYCB Tolerance :\u003c\/strong\u003e 1.0 ±mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Resistance (at 20°C) (Max):\u003c\/strong\u003e 0.126 Ω\/km\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eInsulation Resistance (at 20°C) (Min):\u003c\/strong\u003e 350 ㏁ - km\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCable Weight :\u003c\/strong\u003e 1.2978 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003e1 Core 150 mm² JIS C 3410 0.6\/1KV SPYC \/ SPYCB Shipboard Flame Retardant Power Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e for 1 Core 150 mm² JIS C 3410 0.6\/1KV SPYC \/ SPYCB Shipboard Flame Retardant Power Cable: 100 \u003cstrong\u003eAmps\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Design guide : JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• Flame retardant :  IEC60332-1\u003cbr\u003e                              :  IEC 60332-3 Category A (FA-Cables Only)\u003c\/li\u003e\n\u003cli\u003e• Cold bend\/impact : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Max. rated conductor temperature : 90℃\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, \u003cspan data-mce-fragment=\"1\"\u003eJIS C 3410 Cable, 0.6\/1KV SPYC, SPYCB Cable, Flame Retardant Cable, Power Cable, Tinned Annealed Copper\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e\u003cbr\u003eConductor :\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Code\u003c\/strong\u003e : S\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e• Stranded tinned annealed copper wires as per JIS C 3410(2010)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e• A suitable tape may be applied on the conductor\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e\u003cbr\u003eInsulation :\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Code \u003c\/strong\u003e: P\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e• EPR as per JIS C 3410(2010)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e\u003cbr\u003eCabling :\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Insulated conductors shall be cabled\u003c\/li\u003e\n\u003cli\u003e• Flame retardant \u0026amp; non-hygroscopic fillers may be used.\u003c\/li\u003e\n\u003cli\u003e• Suitable tape(s) may be applied on the cabled core.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSheath\u003c\/strong\u003e :\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC as per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eArmour\u003c\/strong\u003e :\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003e• Braid of galvanized steel wire(C) or copper alloy wire(CB)\u003c\/li\u003e\n\u003cli\u003e• Coverage density : Min. 90%\u003c\/li\u003e\n\u003cli\u003e• A suitable separator tape(s) may be applied under\/over the armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003ePaint\u003c\/strong\u003e :\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• The white paint shall be painted uniformly on the steel wire braid\u003c\/li\u003e\n\u003cli\u003e• In case of PVC protective covering cable, paint isdispensable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eProtective Covering\u003c\/strong\u003e :\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC as per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eProtective covering color\u003c\/strong\u003e : Black\u003c\/li\u003e\n\u003cli\u003e• Any other color may be applicable when purchaser required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39626631446682,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/FA-_SPYC_748374bd-f0df-4482-bb60-95d54d41bee5.png?v=1759812423"},{"product_id":"1-core-185-mm-jis-c-3410-0-6-1kv-spyc-spycb-shipboard-flame-retardant-power-cable","title":"1 Core 185 mm² JIS C 3410 0.6\/1KV SPYC \/ SPYCB Shipboard Flame Retardant Power Cable","description":"[short]\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eNo. of Cores :\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Nominal Area :\u003c\/strong\u003e 185 mm²\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Strand :\u003c\/strong\u003e 37\/2.52 No.\/mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Dia. :\u003c\/strong\u003e 17.60 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eNominal Dia. Over Sheath :\u003c\/strong\u003e 25.5 mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eSPYC \/ SPYCB Nominal Dia. :\u003c\/strong\u003e 26.8 \u003cspan data-mce-fragment=\"1\"\u003emm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eSPYC \/ SPYCB Tolerance :\u003c\/strong\u003e 1.1 ±mm\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eConductor Resistance (at 20°C) (Max):\u003c\/strong\u003e 0.100 Ω\/km\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eInsulation Resistance (at 20°C) (Min):\u003c\/strong\u003e 350 ㏁ - km\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eCable Weight :\u003c\/strong\u003e 1.5945 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003e1 Core 185 mm² JIS C 3410 0.6\/1KV SPYC \/ SPYCB Shipboard Flame Retardant Power Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e for 1 Core 185 mm² JIS C 3410 0.6\/1KV SPYC \/ SPYCB Shipboard Flame Retardant Power Cable: 100 \u003cstrong\u003eAmps\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Design guide : JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003e• Flame retardant :  IEC60332-1\u003cbr\u003e                              :  IEC 60332-3 Category A (FA-Cables Only)\u003c\/li\u003e\n\u003cli\u003e• Cold bend\/impact : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003e• Max. rated conductor temperature : 90℃\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eAlso Known As:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, \u003cspan data-mce-fragment=\"1\"\u003eJIS C 3410 Cable, 0.6\/1KV SPYC, SPYCB Cable, Flame Retardant Cable, Power Cable, Tinned Annealed Copper\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Code\u003c\/strong\u003e : S\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e• Stranded tinned annealed copper wires as per JIS C 3410(2010)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e• A suitable tape may be applied on the conductor\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e\u003cbr\u003eInsulation :\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Code \u003c\/strong\u003e: P\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e• EPR as per JIS C 3410(2010)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e\u003cbr\u003eCabling :\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• Insulated conductors shall be cabled\u003c\/li\u003e\n\u003cli\u003e• Flame retardant \u0026amp; non-hygroscopic fillers may be used.\u003c\/li\u003e\n\u003cli\u003e• Suitable tape(s) may be applied on the cabled core.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eSheath\u003c\/strong\u003e :\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC as per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eArmour\u003c\/strong\u003e :\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003e• Braid of galvanized steel wire(C) or copper alloy wire(CB)\u003c\/li\u003e\n\u003cli\u003e• Coverage density : Min. 90%\u003c\/li\u003e\n\u003cli\u003e• A suitable separator tape(s) may be applied under\/over the armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003ePaint\u003c\/strong\u003e :\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• The white paint shall be painted uniformly on the steel wire braid\u003c\/li\u003e\n\u003cli\u003e• In case of PVC protective covering cable, paint isdispensable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eProtective Covering\u003c\/strong\u003e :\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e• \u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003e• PVC as per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e• \u003cstrong\u003eProtective covering color\u003c\/strong\u003e : Black\u003c\/li\u003e\n\u003cli\u003e• Any other color may be applicable when purchaser required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39626652352666,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/FA-_SPYC_8ace0156-fc9c-449f-8ed8-a3291b49d810.png?v=1762482728"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/collections\/marine-cables-and-tools-bold.png?v=1785845772","url":"https:\/\/nassaunationalcable.com\/collections\/marine-cables-and-tools.oembed?page=2","provider":"NassauNationalCable","version":"1.0","type":"link"}