{"title":"JIS C 3410 6\/10KV (FA-)TPYCY Shipboard Flame Retardant Medium Voltage Cable","description":"","products":[{"product_id":"3-cores-10-mm-jis-c-3410-6-10kv-fa-tpycy-shipboard-flame-retardant-medium-voltage-cable","title":"3 Cores 10 mm² JIS C 3410 6\/10KV (FA-)TPYCY Shipboard Flame Retardant Medium Voltage Cable","description":"\u003cp\u003e\u003cstrong\u003e3 Cores 10 mm² JIS C 3410 6\/10KV (FA-)TPYCY Shipboard Flame Retardant Medium Voltage Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e For 3 Cores 10 mm² JIS C 3410 6\/10KV (FA-)TPYCY Shipboard Flame Retardant Medium Voltage Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDesign Guide : JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003eFlame Retardant : IEC60332-1\u003cbr\u003e                               : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003eCold Bend\/impact : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003eMax. Rated Conductor Temperature : 90℃\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, JIS C 3410 6\/10KV Cable, (FA-)TPYCY Cable, Galvanized Steel, PVC Cable, Insulated Conductors, Stranded Tinned Copper, Flame Retardant Cable, Twisted Pairs, Tinned Annealed Copper, Medium Voltage Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : S,T\u003c\/li\u003e\n\u003cli\u003eStranded Tinned Annealed Copper Wires As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003eA Suitable Tape May Be Applied On The Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSemi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : P\u003c\/li\u003e\n\u003cli\u003eEPR As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-metallic Part\u003c\/strong\u003e : Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMetallic Part\u003c\/strong\u003e : Copper Tape With About 0.1mm Thickness\u003c\/li\u003e\n\u003cli\u003eA Suitable Separator Tape(S) May Be Applied Over The Metallic Part\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCabling\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThree Insulation Screened Conductors Shall Be Cabled\u003c\/li\u003e\n\u003cli\u003eFlame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003c\/li\u003e\n\u003cli\u003eSuitable Tape(S) May Be Applied On The Cabled Core\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSheath :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003ePVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eArmour\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003eBraid Of Galvanized Steel Wire(C) Or Copper Alloy Wire(CB)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoverage Density\u003c\/strong\u003e : Min. 90%\u003c\/li\u003e\n\u003cli\u003eA Suitable Separator Tape(S) May Be Applied Under\/over The Armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePaint\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe Red Paint Shall Be Painted Uniformly On The Steel Wire Braid.\u003c\/li\u003e\n\u003cli\u003eIn Case Of PVC Outer Sheath Cable, Paint Is Dispensable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eProtective Covering\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003ePVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOuter Sheath Color\u003c\/strong\u003e : Red\u003c\/li\u003e\n\u003cli\u003eAny Other Color May Be Applicable When Purchaser Required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCore Identification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3C\u003c\/strong\u003e : Red, Yellow,Blue\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo. Of Cores\u003c\/strong\u003e : 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Nominal Area\u003c\/strong\u003e : 10 mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Strand\u003c\/strong\u003e : 7\/1.35 No.\/mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Dia.\u003c\/strong\u003e : 4.05 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(FA-)TPYCY Nominal Overall Dia.\u003c\/strong\u003e : 37.5 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(FA-)TPYCY Tolerance\u003c\/strong\u003e : 1.5 ±mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Resistance (at 20°C) (Max)\u003c\/strong\u003e : 1.840 Ω\/km\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Weight\u003c\/strong\u003e : 1.3052 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39757258326170,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/FA-_SPYCB_a4ecb74f-d3c2-47e6-9e26-28f6dd28a90e.png?v=1762483788"},{"product_id":"3-cores-16-mm-jis-c-3410-6-10kv-fa-tpycy-shipboard-flame-retardant-medium-voltage-cable","title":"3 Cores 16 mm² JIS C 3410 6\/10KV (FA-)TPYCY Shipboard Flame Retardant Medium Voltage Cable","description":"\u003cp\u003e\u003cstrong\u003e3 Cores 16 mm² JIS C 3410 6\/10KV (FA-)TPYCY Shipboard Flame Retardant Medium Voltage Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e For 3 Cores 16 mm² JIS C 3410 6\/10KV (FA-)TPYCY Shipboard Flame Retardant Medium Voltage Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDesign Guide : JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003eFlame Retardant : IEC60332-1\u003cbr\u003e                               : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003eCold Bend\/impact : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003eMax. Rated Conductor Temperature : 90℃\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, JIS C 3410 6\/10KV Cable, (FA-)TPYCY Cable, Galvanized Steel, PVC Cable, Insulated Conductors, Stranded Tinned Copper, Flame Retardant Cable, Twisted Pairs, Tinned Annealed Copper, Medium Voltage Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : S,T\u003c\/li\u003e\n\u003cli\u003eStranded Tinned Annealed Copper Wires As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003eA Suitable Tape May Be Applied On The Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSemi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : P\u003c\/li\u003e\n\u003cli\u003eEPR As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-metallic Part\u003c\/strong\u003e : Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMetallic Part\u003c\/strong\u003e : Copper Tape With About 0.1mm Thickness\u003c\/li\u003e\n\u003cli\u003eA Suitable Separator Tape(S) May Be Applied Over The Metallic Part\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCabling\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThree Insulation Screened Conductors Shall Be Cabled\u003c\/li\u003e\n\u003cli\u003eFlame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003c\/li\u003e\n\u003cli\u003eSuitable Tape(S) May Be Applied On The Cabled Core\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSheath :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003ePVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eArmour\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003eBraid Of Galvanized Steel Wire(C) Or Copper Alloy Wire(CB)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoverage Density\u003c\/strong\u003e : Min. 90%\u003c\/li\u003e\n\u003cli\u003eA Suitable Separator Tape(S) May Be Applied Under\/over The Armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePaint\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe Red Paint Shall Be Painted Uniformly On The Steel Wire Braid.\u003c\/li\u003e\n\u003cli\u003eIn Case Of PVC Outer Sheath Cable, Paint Is Dispensable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eProtective Covering\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003ePVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOuter Sheath Color\u003c\/strong\u003e : Red\u003c\/li\u003e\n\u003cli\u003eAny Other Color May Be Applicable When Purchaser Required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCore Identification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3C\u003c\/strong\u003e : Red, Yellow,Blue\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo. Of Cores\u003c\/strong\u003e : 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Nominal Area\u003c\/strong\u003e : 16 mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Strand\u003c\/strong\u003e : 7\/1.70 No.\/mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Dia.\u003c\/strong\u003e : 5.10 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(FA-)TPYCY Nominal Overall Dia.\u003c\/strong\u003e : 39.9 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(FA-)TPYCY Tolerance\u003c\/strong\u003e : 1.6 ±mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Resistance (at 20°C) (Max)\u003c\/strong\u003e : 1.840 Ω\/km\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Weight\u003c\/strong\u003e : 1.5309 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39757332742298,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/FA-_SPYCB_3a73d9f5-e49f-4505-a97b-a03b5f58a5f7.png?v=1759812866"},{"product_id":"3-cores-25-mm-jis-c-3410-6-10kv-fa-tpycy-shipboard-flame-retardant-medium-voltage-cable","title":"3 Cores 25 mm² JIS C 3410 6\/10KV (FA-)TPYCY Shipboard Flame Retardant Medium Voltage Cable","description":"\u003cp\u003e\u003cstrong\u003e3 Cores 25 mm² JIS C 3410 6\/10KV (FA-)TPYCY Shipboard Flame Retardant Medium Voltage Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e For 3 Cores 25 mm² JIS C 3410 6\/10KV (FA-)TPYCY Shipboard Flame Retardant Medium Voltage Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDesign Guide : JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003eFlame Retardant : IEC60332-1\u003cbr\u003e                               : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003eCold Bend\/impact : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003eMax. Rated Conductor Temperature : 90℃\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, JIS C 3410 6\/10KV Cable, (FA-)TPYCY Cable, Galvanized Steel, PVC Cable, Insulated Conductors, Stranded Tinned Copper, Flame Retardant Cable, Twisted Pairs, Tinned Annealed Copper, Medium Voltage Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : S,T\u003c\/li\u003e\n\u003cli\u003eStranded Tinned Annealed Copper Wires As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003eA Suitable Tape May Be Applied On The Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSemi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : P\u003c\/li\u003e\n\u003cli\u003eEPR As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-metallic Part\u003c\/strong\u003e : Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMetallic Part\u003c\/strong\u003e : Copper Tape With About 0.1mm Thickness\u003c\/li\u003e\n\u003cli\u003eA Suitable Separator Tape(S) May Be Applied Over The Metallic Part\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCabling\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThree Insulation Screened Conductors Shall Be Cabled\u003c\/li\u003e\n\u003cli\u003eFlame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003c\/li\u003e\n\u003cli\u003eSuitable Tape(S) May Be Applied On The Cabled Core\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSheath :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003ePVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eArmour\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003eBraid Of Galvanized Steel Wire(C) Or Copper Alloy Wire(CB)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoverage Density\u003c\/strong\u003e : Min. 90%\u003c\/li\u003e\n\u003cli\u003eA Suitable Separator Tape(S) May Be Applied Under\/over The Armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePaint\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe Red Paint Shall Be Painted Uniformly On The Steel Wire Braid.\u003c\/li\u003e\n\u003cli\u003eIn Case Of PVC Outer Sheath Cable, Paint Is Dispensable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eProtective Covering\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003ePVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOuter Sheath Color\u003c\/strong\u003e : Red\u003c\/li\u003e\n\u003cli\u003eAny Other Color May Be Applicable When Purchaser Required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCore Identification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3C\u003c\/strong\u003e : Red, Yellow,Blue\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo. Of Cores\u003c\/strong\u003e : 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Nominal Area\u003c\/strong\u003e : 25 mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Strand\u003c\/strong\u003e : 7\/2.14 No.\/mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Dia.\u003c\/strong\u003e : 6.42 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(FA-)TPYCY Nominal Overall Dia.\u003c\/strong\u003e : 43.2 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(FA-)TPYCY Tolerance\u003c\/strong\u003e : 1.7 ±mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Resistance (at 20°C) (Max)\u003c\/strong\u003e : 0.734 Ω\/km\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Weight\u003c\/strong\u003e : 1.8690 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39757381697690,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/FA-_SPYCB_dc05e745-6a94-4cd6-bee1-14e1cb770201.png?v=1762483791"},{"product_id":"3-cores-35-mm-jis-c-3410-6-10kv-fa-tpycy-shipboard-flame-retardant-medium-voltage-cable","title":"3 Cores 35 mm² JIS C 3410 6\/10KV (FA-)TPYCY Shipboard Flame Retardant Medium Voltage Cable","description":"\u003cp\u003e\u003cstrong\u003e3 Cores 35 mm² JIS C 3410 6\/10KV (FA-)TPYCY Shipboard Flame Retardant Medium Voltage Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e For 3 Cores 35 mm² JIS C 3410 6\/10KV (FA-)TPYCY Shipboard Flame Retardant Medium Voltage Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDesign Guide : JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003eFlame Retardant : IEC60332-1\u003cbr\u003e                               : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003eCold Bend\/impact : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003eMax. Rated Conductor Temperature : 90℃\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, JIS C 3410 6\/10KV Cable, (FA-)TPYCY Cable, Galvanized Steel, PVC Cable, Insulated Conductors, Stranded Tinned Copper, Flame Retardant Cable, Twisted Pairs, Tinned Annealed Copper, Medium Voltage Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : S,T\u003c\/li\u003e\n\u003cli\u003eStranded Tinned Annealed Copper Wires As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003eA Suitable Tape May Be Applied On The Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSemi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : P\u003c\/li\u003e\n\u003cli\u003eEPR As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-metallic Part\u003c\/strong\u003e : Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMetallic Part\u003c\/strong\u003e : Copper Tape With About 0.1mm Thickness\u003c\/li\u003e\n\u003cli\u003eA Suitable Separator Tape(S) May Be Applied Over The Metallic Part\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCabling\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThree Insulation Screened Conductors Shall Be Cabled\u003c\/li\u003e\n\u003cli\u003eFlame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003c\/li\u003e\n\u003cli\u003eSuitable Tape(S) May Be Applied On The Cabled Core\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSheath :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003ePVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eArmour\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003eBraid Of Galvanized Steel Wire(C) Or Copper Alloy Wire(CB)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoverage Density\u003c\/strong\u003e : Min. 90%\u003c\/li\u003e\n\u003cli\u003eA Suitable Separator Tape(S) May Be Applied Under\/over The Armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePaint\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe Red Paint Shall Be Painted Uniformly On The Steel Wire Braid.\u003c\/li\u003e\n\u003cli\u003eIn Case Of PVC Outer Sheath Cable, Paint Is Dispensable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eProtective Covering\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003ePVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOuter Sheath Color\u003c\/strong\u003e : Red\u003c\/li\u003e\n\u003cli\u003eAny Other Color May Be Applicable When Purchaser Required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCore Identification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3C\u003c\/strong\u003e : Red, Yellow,Blue\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo. Of Cores\u003c\/strong\u003e : 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Nominal Area\u003c\/strong\u003e : 35 mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Strand\u003c\/strong\u003e : 7\/2.52 No.\/mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Dia.\u003c\/strong\u003e : 7.56 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(FA-)TPYCY Nominal Overall Dia.\u003c\/strong\u003e : 46.0 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(FA-)TPYCY Tolerance\u003c\/strong\u003e : 1.7 ±mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Resistance (at 20°C) (Max)\u003c\/strong\u003e : 0.529 Ω\/km\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Weight\u003c\/strong\u003e : 2.2008 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39757423837338,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/FA-_SPYCB_67cdd64f-1f03-4644-948f-130ce1f62b8b.png?v=1759812867"},{"product_id":"3-cores-50-mm-jis-c-3410-6-10kv-fa-tpycy-shipboard-flame-retardant-medium-voltage-cable","title":"3 Cores 50 mm² JIS C 3410 6\/10KV (FA-)TPYCY Shipboard Flame Retardant Medium Voltage Cable","description":"\u003cp\u003e\u003cstrong\u003e3 Cores 50 mm² JIS C 3410 6\/10KV (FA-)TPYCY Shipboard Flame Retardant Medium Voltage Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e For 3 Cores 50 mm² JIS C 3410 6\/10KV (FA-)TPYCY Shipboard Flame Retardant Medium Voltage Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDesign Guide : JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003eFlame Retardant : IEC60332-1\u003cbr\u003e                               : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003eCold Bend\/impact : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003eMax. Rated Conductor Temperature : 90℃\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, JIS C 3410 6\/10KV Cable, (FA-)\u003cspan data-mce-fragment=\"1\"\u003eTPYCY \u003c\/span\u003eCable, Galvanized Steel, PVC Cable, Insulated Conductors, Stranded Tinned Copper, Flame Retardant Cable, Twisted Pairs, Tinned Annealed Copper, Medium Voltage Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : S,T\u003c\/li\u003e\n\u003cli\u003eStranded Tinned Annealed Copper Wires As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003eA Suitable Tape May Be Applied On The Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSemi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : P\u003c\/li\u003e\n\u003cli\u003eEPR As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-metallic Part\u003c\/strong\u003e : Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMetallic Part\u003c\/strong\u003e : Copper Tape With About 0.1mm Thickness\u003c\/li\u003e\n\u003cli\u003eA Suitable Separator Tape(S) May Be Applied Over The Metallic Part\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCabling\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThree Insulation Screened Conductors Shall Be Cabled\u003c\/li\u003e\n\u003cli\u003eFlame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003c\/li\u003e\n\u003cli\u003eSuitable Tape(S) May Be Applied On The Cabled Core\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSheath :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003ePVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eArmour\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003eBraid Of Galvanized Steel Wire(C) Or Copper Alloy Wire(CB)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoverage Density\u003c\/strong\u003e : Min. 90%\u003c\/li\u003e\n\u003cli\u003eA Suitable Separator Tape(S) May Be Applied Under\/over The Armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePaint\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe Red Paint Shall Be Painted Uniformly On The Steel Wire Braid.\u003c\/li\u003e\n\u003cli\u003eIn Case Of PVC Outer Sheath Cable, Paint Is Dispensable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eProtective Covering\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003ePVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOuter Sheath Color\u003c\/strong\u003e : Red\u003c\/li\u003e\n\u003cli\u003eAny Other Color May Be Applicable When Purchaser Required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCore Identification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3C\u003c\/strong\u003e : Red, Yellow,Blue\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo. Of Cores\u003c\/strong\u003e : 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Nominal Area\u003c\/strong\u003e : 50 mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Strand\u003c\/strong\u003e : 19\/1.78 No.\/mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Dia.\u003c\/strong\u003e : 8.90 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(FA-)\u003cspan data-mce-fragment=\"1\"\u003eTPYCY \u003c\/span\u003eNominal Overall Dia.\u003c\/strong\u003e : 49.3 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(FA-)\u003cspan data-mce-fragment=\"1\"\u003eTPYCY \u003c\/span\u003eTolerance\u003c\/strong\u003e : 1.8 ±mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Resistance (at 20°C) (Max)\u003c\/strong\u003e : 0.391 Ω\/km\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Weight\u003c\/strong\u003e : 2.6177 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39757585580186,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/FA-_SPYCB_426f6380-771e-45ba-a89e-e0493defd978.png?v=1762483795"},{"product_id":"3-cores-95-mm-jis-c-3410-6-10kv-fa-tpycy-shipboard-flame-retardant-medium-voltage-cable","title":"3 Cores 95 mm² JIS C 3410 6\/10KV (FA-)TPYCY Shipboard Flame Retardant Medium Voltage Cable","description":"\u003cp\u003e\u003cstrong\u003e3 Cores 95 mm² JIS C 3410 6\/10KV (FA-)TPYCY Shipboard Flame Retardant Medium Voltage Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e For 3 Cores 95 mm² JIS C 3410 6\/10KV (FA-)TPYCY Shipboard Flame Retardant Medium Voltage Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDesign Guide : JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003eFlame Retardant : IEC60332-1\u003cbr\u003e                               : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003eCold Bend\/impact : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003eMax. Rated Conductor Temperature : 90℃\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, JIS C 3410 6\/10KV Cable, (FA-)TPYCY Cable, Galvanized Steel, PVC Cable, Insulated Conductors, Stranded Tinned Copper, Flame Retardant Cable, Twisted Pairs, Tinned Annealed Copper, Medium Voltage Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : S,T\u003c\/li\u003e\n\u003cli\u003eStranded Tinned Annealed Copper Wires As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003eA Suitable Tape May Be Applied On The Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSemi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : P\u003c\/li\u003e\n\u003cli\u003eEPR As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-metallic Part\u003c\/strong\u003e : Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMetallic Part\u003c\/strong\u003e : Copper Tape With About 0.1mm Thickness\u003c\/li\u003e\n\u003cli\u003eA Suitable Separator Tape(S) May Be Applied Over The Metallic Part\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCabling\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThree Insulation Screened Conductors Shall Be Cabled\u003c\/li\u003e\n\u003cli\u003eFlame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003c\/li\u003e\n\u003cli\u003eSuitable Tape(S) May Be Applied On The Cabled Core\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSheath :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003ePVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eArmour\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003eBraid Of Galvanized Steel Wire(C) Or Copper Alloy Wire(CB)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoverage Density\u003c\/strong\u003e : Min. 90%\u003c\/li\u003e\n\u003cli\u003eA Suitable Separator Tape(S) May Be Applied Under\/over The Armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePaint\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe Red Paint Shall Be Painted Uniformly On The Steel Wire Braid.\u003c\/li\u003e\n\u003cli\u003eIn Case Of PVC Outer Sheath Cable, Paint Is Dispensable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eProtective Covering\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003ePVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOuter Sheath Color\u003c\/strong\u003e : Red\u003c\/li\u003e\n\u003cli\u003eAny Other Color May Be Applicable When Purchaser Required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCore Identification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3C\u003c\/strong\u003e : Red, Yellow,Blue\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo. Of Cores\u003c\/strong\u003e : 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Nominal Area\u003c\/strong\u003e : 95 mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Strand\u003c\/strong\u003e : 19\/2.52 No.\/mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Dia.\u003c\/strong\u003e : 12.60 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(FA-)TPYCY Nominal Overall Dia.\u003c\/strong\u003e : 58.5 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(FA-)TPYCY Tolerance\u003c\/strong\u003e : 2.0 ±mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Resistance (at 20°C) (Max)\u003c\/strong\u003e : 0.195 Ω\/km\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Weight\u003c\/strong\u003e : 4.0499 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39757753614490,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/FA-_SPYCB_ef77df8d-ef85-47b4-9504-f64d24c2137e.png?v=1759812868"},{"product_id":"3-cores-120-mm-jis-c-3410-6-10kv-fa-tpycy-shipboard-flame-retardant-medium-voltage-cable","title":"3 Cores 120 mm² JIS C 3410 6\/10KV (FA-)TPYCY Shipboard Flame Retardant Medium Voltage Cable","description":"\u003cp\u003e\u003cstrong\u003e3 Cores 120 mm² JIS C 3410 6\/10KV (FA-)TPYCY Shipboard Flame Retardant Medium Voltage Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e For 3 Cores 120 mm² JIS C 3410 6\/10KV (FA-)TPYCY Shipboard Flame Retardant Medium Voltage Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDesign Guide : JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003eFlame Retardant : IEC60332-1\u003cbr\u003e                               : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003eCold Bend\/impact : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003eMax. Rated Conductor Temperature : 90℃\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, JIS C 3410 6\/10KV Cable, (FA-)TPYCY Cable, Galvanized Steel, PVC Cable, Insulated Conductors, Stranded Tinned Copper, Flame Retardant Cable, Twisted Pairs, Tinned Annealed Copper, Medium Voltage Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : S,T\u003c\/li\u003e\n\u003cli\u003eStranded Tinned Annealed Copper Wires As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003eA Suitable Tape May Be Applied On The Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSemi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : P\u003c\/li\u003e\n\u003cli\u003eEPR As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-metallic Part\u003c\/strong\u003e : Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMetallic Part\u003c\/strong\u003e : Copper Tape With About 0.1mm Thickness\u003c\/li\u003e\n\u003cli\u003eA Suitable Separator Tape(S) May Be Applied Over The Metallic Part\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCabling\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThree Insulation Screened Conductors Shall Be Cabled\u003c\/li\u003e\n\u003cli\u003eFlame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003c\/li\u003e\n\u003cli\u003eSuitable Tape(S) May Be Applied On The Cabled Core\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSheath :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003ePVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eArmour\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003eBraid Of Galvanized Steel Wire(C) Or Copper Alloy Wire(CB)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoverage Density\u003c\/strong\u003e : Min. 90%\u003c\/li\u003e\n\u003cli\u003eA Suitable Separator Tape(S) May Be Applied Under\/over The Armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePaint\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe Red Paint Shall Be Painted Uniformly On The Steel Wire Braid.\u003c\/li\u003e\n\u003cli\u003eIn Case Of PVC Outer Sheath Cable, Paint Is Dispensable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eProtective Covering\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003ePVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOuter Sheath Color\u003c\/strong\u003e : Red\u003c\/li\u003e\n\u003cli\u003eAny Other Color May Be Applicable When Purchaser Required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCore Identification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3C\u003c\/strong\u003e : Red, Yellow,Blue\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo. Of Cores\u003c\/strong\u003e : 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Nominal Area\u003c\/strong\u003e : 120 mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Strand\u003c\/strong\u003e : 37\/2.03 No.\/mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Dia.\u003c\/strong\u003e : 14.21 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(FA-)TPYCY Nominal Overall Dia.\u003c\/strong\u003e : 62.2 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(FA-)TPYCY Tolerance\u003c\/strong\u003e : 2.1 ±mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Resistance (at 20°C) (Max)\u003c\/strong\u003e : 0.154 Ω\/km\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Weight\u003c\/strong\u003e : 4.7408 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39757976961178,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/FA-_SPYCB_ebf16938-a4a5-4e8c-8fd7-696ec1cb9eb7.png?v=1762483799"},{"product_id":"3-cores-70-mm-jis-c-3410-6-10kv-fa-tpycy-shipboard-flame-retardant-medium-voltage-cable","title":"3 Cores 70 mm² JIS C 3410 6\/10KV (FA-)TPYCY Shipboard Flame Retardant Medium Voltage Cable","description":"\u003cp\u003e\u003cstrong\u003e3 Cores 70 mm² JIS C 3410 6\/10KV (FA-)TPYCY Shipboard Flame Retardant Medium Voltage Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003c\/strong\u003e For 3 Cores 70 mm² JIS C 3410 6\/10KV (FA-)TPYCY Shipboard Flame Retardant Medium Voltage Cable : \u003cstrong\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Standard :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDesign Guide : JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003eFlame Retardant : IEC60332-1\u003cbr\u003e                               : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003eCold Bend\/impact : CSA 22.2 No. 03 (-40℃\/-35℃) (Cold Type Only)\u003c\/li\u003e\n\u003cli\u003eMax. Rated Conductor Temperature : 90℃\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipboard Cable, JIS C 3410 6\/10KV Cable, (FA-)\u003cspan data-mce-fragment=\"1\"\u003eTPYCY \u003c\/span\u003eCable, Galvanized Steel, PVC Cable, Insulated Conductors, Stranded Tinned Copper, Flame Retardant Cable, Twisted Pairs, Tinned Annealed Copper, Medium Voltage Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : S,T\u003c\/li\u003e\n\u003cli\u003eStranded Tinned Annealed Copper Wires As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003cli\u003eA Suitable Tape May Be Applied On The Conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSemi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : P\u003c\/li\u003e\n\u003cli\u003eEPR As Per JIS C 3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Screen\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-metallic Part\u003c\/strong\u003e : Semi-conducting Layer (Tape\/compound)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMetallic Part\u003c\/strong\u003e : Copper Tape With About 0.1mm Thickness\u003c\/li\u003e\n\u003cli\u003eA Suitable Separator Tape(S) May Be Applied Over The Metallic Part\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCabling\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThree Insulation Screened Conductors Shall Be Cabled\u003c\/li\u003e\n\u003cli\u003eFlame Retardant \u0026amp; Non-hygroscopic Fillers May Be Used\u003c\/li\u003e\n\u003cli\u003eSuitable Tape(S) May Be Applied On The Cabled Core\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSheath :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003ePVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eArmour\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : C (CB)\u003c\/li\u003e\n\u003cli\u003eBraid Of Galvanized Steel Wire(C) Or Copper Alloy Wire(CB)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoverage Density\u003c\/strong\u003e : Min. 90%\u003c\/li\u003e\n\u003cli\u003eA Suitable Separator Tape(S) May Be Applied Under\/over The Armour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePaint\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe Red Paint Shall Be Painted Uniformly On The Steel Wire Braid.\u003c\/li\u003e\n\u003cli\u003eIn Case Of PVC Outer Sheath Cable, Paint Is Dispensable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eProtective Covering\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode\u003c\/strong\u003e : Y\u003c\/li\u003e\n\u003cli\u003ePVC As Per JIS C3410(2010)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOuter Sheath Color\u003c\/strong\u003e : Red\u003c\/li\u003e\n\u003cli\u003eAny Other Color May Be Applicable When Purchaser Required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCore Identification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3C\u003c\/strong\u003e : Red, Yellow,Blue\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e :\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo. Of Cores\u003c\/strong\u003e : 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Nominal Area\u003c\/strong\u003e : 70 mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Strand\u003c\/strong\u003e : 19\/2.14 No.\/mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Dia.\u003c\/strong\u003e : 10.7 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(FA-)\u003cspan data-mce-fragment=\"1\"\u003eTPYCY \u003c\/span\u003eNominal Overall Dia.\u003c\/strong\u003e : 58.5 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(FA-)\u003cspan data-mce-fragment=\"1\"\u003eTPYCY \u003c\/span\u003eTolerance\u003c\/strong\u003e : 2.0 ±mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Resistance (at 20°C) (Max)\u003c\/strong\u003e : 0.270 Ω\/km\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Weight\u003c\/strong\u003e : 3.2519 Lbs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":39893287174298,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/as.png?v=1759813163"}],"url":"https:\/\/nassaunationalcable.com\/collections\/jis-c-3410-6-10kv-fa-tpycy-shipboard-flame-retardant-medium-voltage-cable.oembed","provider":"NassauNationalCable","version":"1.0","type":"link"}