{"title":"HVTECK Copper 1\/C 220 mil TRXLPE CB AIA 15kV 133% IL Red PVC Jacket CSA","description":"","products":[{"product_id":"2-awg-hvteck-copper-220-mil-trxlpe-cb-aia-15kv-133-il-red-pvc-jacket-csa","title":"2 AWG HVTECK Copper 220 mil TRXLPE CB AIA 15KV 133% IL Red PVC Jacket CSA","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC26316_1.pdf?v=1756371899\" width=\"\" height=\"\" type=\"application\/pdf\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2 AWG HVTECK Copper 220 mil TRXLPE CB AIA 15KV 133% IL Red PVC Jacket CSA\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 15kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications. Rated FT4, -40°C, Hazardous Locations (HL). These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lbs \/FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids and are flame retardant.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e2 AWG HVTECK Copper 1\/C 15kV TRXLPE cable, 220 mil TRXLPE 15kV copper wire, HVTECK 15kV red PVC jacket wire, 15kV TRXLPE copper cable CSA, 2 AWG 220 mil TRXLPE copper wire 15kV, Copper 1\/C 15kV TRXLPE insulated wire, 15kV 133% IL copper wire CSA, HVTECK TRXLPE AIA 15kV cable, Red PVC jacketed 15kV copper wire, 2 AWG HVTECK 220 mil TRXLPE 15kV cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and ASTM B8\u003cstrong\u003e\u003cbr\u003e• Conductor Shield: \u003c\/strong\u003eSemi-conducting cross-linked copolymer\u003cstrong\u003e\u003cbr\u003e• Insulation: \u003c\/strong\u003e220 Mils Tree Retardant Cross Linked Polyethylene 133% insulation level\u003cstrong\u003e\u003cbr\u003e•  Insulation Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eStrippable semi-conducting cross-linked copolymer\u003cstrong\u003e\u003cbr\u003e• Concentric Shield: \u003c\/strong\u003eConcentrically applied copper bond \/ shield wires. Complies with greater than the minimum requirement as per Table 44, CSA Standard C68.10 and Table 16A, Canadian Electrical Code Part 1\u003cstrong\u003e\u003cbr\u003e•  Neutral Separator:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMylar tape\u003cstrong\u003e\u003cbr\u003e•  Inner Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ePVC inner jacket\u003cstrong\u003e\u003cbr\u003e• Armour: \u003c\/strong\u003eAluminum Interlocked Armour (AIA)\u003cstrong\u003e\u003cbr\u003e• Overall Jacket: \u003c\/strong\u003eRed Polyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA C22.2 No. 174 Cables in Hazardous Locations\u003cbr\u003e• CSA C22.2 No. 2556 \u0026amp; No. 0.3 Wire and Cable Test Methods\u003cbr\u003e• CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV\u003cbr\u003e• CSA C68.3 Shielded \u0026amp; Concentric Neutral Power Cable - 5 to 46 kV\u003cbr\u003e• CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating\u003cbr\u003e• CSA HL - for Hazardous Locations rating\u003cbr\u003e• CSA SUN RES - for Sunlight Resistant rating\u003cbr\u003e• ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable\u003cbr\u003e• ICEA T-29-520 Flame Test (210,000 BTU\/Hr)\u003cbr\u003e• IEEE 383 Flame Test (70,000 btu)\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test (1\/0 and Larger)\u003cbr\u003e• FT1 Flame Test (1,706 BTU\/Hr nominal - Vertical Wire Flame Test)\u003cbr\u003e• AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2 AWG\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e  7\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor (inch):\u003c\/strong\u003e   0.282\u003cbr\u003e\u003cstrong\u003e• Diameter Over Insulation (inch):\u003c\/strong\u003e  0.760\u003cbr\u003e\u003cstrong\u003e• Insul. Thickness mil: \u003c\/strong\u003e220\u003cbr\u003e\u003cstrong\u003e• Diameter Over Insulation Shield (inch): \u003c\/strong\u003e0.820\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral No. x AWG: \u003c\/strong\u003e7x14\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003cstrong\u003e• Inner Jacket Thickness (mil):\u003c\/strong\u003e   80\u003cbr\u003e\u003cstrong\u003e• Diameter Over Armor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e  1.440\u003cbr\u003e\u003cstrong\u003e• Overall Jacket Thickness mil :\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong\u003e• Approx. OD inch :  \u003c\/strong\u003e1.540\u003cbr\u003e\u003cstrong\u003e• Copper Weight lb\/1000ft: \u003c\/strong\u003e299\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e 1032\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e  18.5\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C Ω \/1000ft:\u003c\/strong\u003e  0.162\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°Ω \/1000ft:\u003c\/strong\u003e   0.204\u003cbr\u003e\u003cstrong\u003e• Inductive Reactance @ 60HzΩ\/1000ft:\u003c\/strong\u003e 0.061\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity In Air 90°C Amp: \u003c\/strong\u003e 215\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity Directly Buried 90°C Amp:  \u003c\/strong\u003e221\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55761659527537,"sku":"NNC12021","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/16_f72b948d-dd21-4d53-bb01-b9600d6944db.png?v=1756372294"},{"product_id":"1-awg-hvteck-copper-220-mil-trxlpe-cb-aia-15kv-133-il-red-pvc-jacket-csa","title":"1 AWG HVTECK Copper 220 mil TRXLPE CB AIA 15KV 133% IL Red PVC Jacket CSA","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC26316_1.pdf?v=1756371899\" width=\"\" height=\"\" type=\"application\/pdf\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1 AWG HVTECK Copper 220 mil TRXLPE CB AIA 15KV 133% IL Red PVC Jacket CSA\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 15kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications. Rated FT4, -40°C, Hazardous Locations (HL). These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lbs \/FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids and are flame retardant.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1 AWG HVTECK Copper 1\/C 15kV TRXLPE cable, 220 mil TRXLPE 15kV copper wire, HVTECK 15kV red PVC jacket wire, 15kV TRXLPE copper cable CSA, 1 AWG 220 mil TRXLPE copper wire 15kV, Copper 1\/C 15kV TRXLPE insulated wire, 15kV 133% IL copper wire CSA, HVTECK TRXLPE AIA 15kV cable, Red PVC jacketed 15kV copper wire, 1 AWG HVTECK 220 mil TRXLPE 15kV cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and ASTM B8\u003cstrong\u003e\u003cbr\u003e• Conductor Shield: \u003c\/strong\u003eSemi-conducting cross-linked copolymer\u003cstrong\u003e\u003cbr\u003e• Insulation: \u003c\/strong\u003e220 Mils Tree Retardant Cross Linked Polyethylene 133% insulation level\u003cstrong\u003e\u003cbr\u003e•  Insulation Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eStrippable semi-conducting cross-linked copolymer\u003cstrong\u003e\u003cbr\u003e• Concentric Shield: \u003c\/strong\u003eConcentrically applied copper bond \/ shield wires. Complies with greater than the minimum requirement as per Table 44, CSA Standard C68.10 and Table 16A, Canadian Electrical Code Part 1\u003cstrong\u003e\u003cbr\u003e•  Neutral Separator:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMylar tape\u003cstrong\u003e\u003cbr\u003e•  Inner Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ePVC inner jacket\u003cstrong\u003e\u003cbr\u003e• Armour: \u003c\/strong\u003eAluminum Interlocked Armour (AIA)\u003cstrong\u003e\u003cbr\u003e• Overall Jacket: \u003c\/strong\u003eRed Polyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA C22.2 No. 174 Cables in Hazardous Locations\u003cbr\u003e• CSA C22.2 No. 2556 \u0026amp; No. 0.3 Wire and Cable Test Methods\u003cbr\u003e• CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV\u003cbr\u003e• CSA C68.3 Shielded \u0026amp; Concentric Neutral Power Cable - 5 to 46 kV\u003cbr\u003e• CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating\u003cbr\u003e• CSA HL - for Hazardous Locations rating\u003cbr\u003e• CSA SUN RES - for Sunlight Resistant rating\u003cbr\u003e• ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable\u003cbr\u003e• ICEA T-29-520 Flame Test (210,000 BTU\/Hr)\u003cbr\u003e• IEEE 383 Flame Test (70,000 btu)\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test (1\/0 and Larger)\u003cbr\u003e• FT1 Flame Test (1,706 BTU\/Hr nominal - Vertical Wire Flame Test)\u003cbr\u003e• AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1 AWG\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e  19\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor (inch):\u003c\/strong\u003e    0.322\u003cbr\u003e\u003cstrong\u003e• Diameter Over Insulation (inch):\u003c\/strong\u003e   0.800 \u003cbr\u003e\u003cstrong\u003e• Insul. Thickness mil: \u003c\/strong\u003e220\u003cbr\u003e\u003cstrong\u003e• Diameter Over Insulation Shield (inch): \u003c\/strong\u003e0.820\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral No. x AWG: \u003c\/strong\u003e11x14\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003cstrong\u003e• Inner Jacket Thickness (mil):\u003c\/strong\u003e   80\u003cbr\u003e\u003cstrong\u003e• Diameter Over Armor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e  1.480\u003cbr\u003e\u003cstrong\u003e• Overall Jacket Thickness mil :\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong\u003e• Approx. OD inch :  \u003c\/strong\u003e1.580\u003cbr\u003e\u003cstrong\u003e• Copper Weight lb\/1000ft:  \u003c\/strong\u003e407\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e 1175\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e  19.0\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C Ω \/1000ft:\u003c\/strong\u003e  0.128\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°Ω \/1000ft:\u003c\/strong\u003e   0.162\u003cbr\u003e\u003cstrong\u003e• Inductive Reactance @ 60HzΩ\/1000ft:\u003c\/strong\u003e 0.058\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity In Air 90°C Amp: \u003c\/strong\u003e 245\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity Directly Buried 90°C Amp:  \u003c\/strong\u003e247\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55761668899185,"sku":"NNC12022","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/16_f72b948d-dd21-4d53-bb01-b9600d6944db.png?v=1756372294"},{"product_id":"1-0-awg-hvteck-copper-220-mil-trxlpe-cb-aia-15kv-133-il-red-pvc-jacket-csa","title":"1\/0 AWG HVTECK Copper 220 mil TRXLPE CB AIA 15KV 133% IL Red PVC Jacket CSA","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC26316_1.pdf?v=1756371899\" width=\"\" height=\"\" type=\"application\/pdf\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1\/0 AWG HVTECK Copper 220 mil TRXLPE CB AIA 15KV 133% IL Red PVC Jacket CSA\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 15kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications. Rated FT4, -40°C, Hazardous Locations (HL). These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lbs \/FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids and are flame retardant.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1\/0 AWG HVTECK Copper 1\/C 15kV TRXLPE cable, 220 mil TRXLPE 15kV copper wire, HVTECK 15kV red PVC jacket wire, 15kV TRXLPE copper cable CSA, 1\/0 AWG 220 mil TRXLPE copper wire 15kV, Copper 1\/C 15kV TRXLPE insulated wire, 15kV 133% IL copper wire CSA, HVTECK TRXLPE AIA 15kV cable, Red PVC jacketed 15kV copper wire, 1\/0 AWG HVTECK 220 mil TRXLPE 15kV cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and ASTM B8\u003cstrong\u003e\u003cbr\u003e• Conductor Shield: \u003c\/strong\u003eSemi-conducting cross-linked copolymer\u003cstrong\u003e\u003cbr\u003e• Insulation: \u003c\/strong\u003e220 Mils Tree Retardant Cross Linked Polyethylene 133% insulation level\u003cstrong\u003e\u003cbr\u003e•  Insulation Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eStrippable semi-conducting cross-linked copolymer\u003cstrong\u003e\u003cbr\u003e• Concentric Shield: \u003c\/strong\u003eConcentrically applied copper bond \/ shield wires. Complies with greater than the minimum requirement as per Table 44, CSA Standard C68.10 and Table 16A, Canadian Electrical Code Part 1\u003cstrong\u003e\u003cbr\u003e•  Neutral Separator:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMylar tape\u003cstrong\u003e\u003cbr\u003e•  Inner Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ePVC inner jacket\u003cstrong\u003e\u003cbr\u003e• Armour: \u003c\/strong\u003eAluminum Interlocked Armour (AIA)\u003cstrong\u003e\u003cbr\u003e• Overall Jacket: \u003c\/strong\u003eRed Polyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA C22.2 No. 174 Cables in Hazardous Locations\u003cbr\u003e• CSA C22.2 No. 2556 \u0026amp; No. 0.3 Wire and Cable Test Methods\u003cbr\u003e• CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV\u003cbr\u003e• CSA C68.3 Shielded \u0026amp; Concentric Neutral Power Cable - 5 to 46 kV\u003cbr\u003e• CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating\u003cbr\u003e• CSA HL - for Hazardous Locations rating\u003cbr\u003e• CSA SUN RES - for Sunlight Resistant rating\u003cbr\u003e• ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable\u003cbr\u003e• ICEA T-29-520 Flame Test (210,000 BTU\/Hr)\u003cbr\u003e• IEEE 383 Flame Test (70,000 btu)\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test (1\/0 and Larger)\u003cbr\u003e• FT1 Flame Test (1,706 BTU\/Hr nominal - Vertical Wire Flame Test)\u003cbr\u003e• AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1\/0 AWG\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e  19\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor (inch):\u003c\/strong\u003e  0.361\u003cbr\u003e\u003cstrong\u003e• Diameter Over Insulation (inch):\u003c\/strong\u003e   0.839 \u003cbr\u003e\u003cstrong\u003e• Insul. Thickness mil: \u003c\/strong\u003e220\u003cbr\u003e\u003cstrong\u003e• Diameter Over Insulation Shield (inch):  \u003c\/strong\u003e0.899\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral No. x AWG: \u003c\/strong\u003e11x14\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003cstrong\u003e• Inner Jacket Thickness (mil):\u003c\/strong\u003e   80\u003cbr\u003e\u003cstrong\u003e• Diameter Over Armor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e  1.519\u003cbr\u003e\u003cstrong\u003e• Overall Jacket Thickness mil :\u003c\/strong\u003e 60\u003cbr\u003e\u003cstrong\u003e• Approx. OD inch : \u003c\/strong\u003e1.639\u003cbr\u003e\u003cstrong\u003e• Copper Weight lb\/1000ft:  \u003c\/strong\u003e474\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e 1308\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e   19.7\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C Ω \/1000ft:\u003c\/strong\u003e  0.102\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°Ω \/1000ft:\u003c\/strong\u003e   0.128\u003cbr\u003e\u003cstrong\u003e• Inductive Reactance @ 60HzΩ\/1000ft:\u003c\/strong\u003e 0.056\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity In Air 90°C Amp: \u003c\/strong\u003e  278\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity Directly Buried 90°C Amp:  \u003c\/strong\u003e275\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55761674338673,"sku":"NNC12023","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/16_f72b948d-dd21-4d53-bb01-b9600d6944db.png?v=1756372294"},{"product_id":"2-0-awg-hvteck-copper-220-mil-trxlpe-cb-aia-15kv-133-il-red-pvc-jacket-csa","title":"2\/0 AWG HVTECK Copper 220 mil TRXLPE CB AIA 15KV 133% IL Red PVC Jacket CSA","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC26316_1.pdf?v=1756371899\" width=\"\" height=\"\" type=\"application\/pdf\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2\/0 AWG HVTECK Copper 220 mil TRXLPE CB AIA 15KV 133% IL Red PVC Jacket CSA\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 15kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications. Rated FT4, -40°C, Hazardous Locations (HL). These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lbs \/FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids and are flame retardant.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e2\/0 AWG HVTECK Copper 1\/C 15kV TRXLPE cable, 220 mil TRXLPE 15kV copper wire, HVTECK 15kV red PVC jacket wire, 15kV TRXLPE copper cable CSA, 2\/0 AWG 220 mil TRXLPE copper wire 15kV, Copper 1\/C 15kV TRXLPE insulated wire, 15kV 133% IL copper wire CSA, HVTECK TRXLPE AIA 15kV cable, Red PVC jacketed 15kV copper wire, 2\/0 AWG HVTECK 220 mil TRXLPE 15kV cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and ASTM B8\u003cstrong\u003e\u003cbr\u003e• Conductor Shield: \u003c\/strong\u003eSemi-conducting cross-linked copolymer\u003cstrong\u003e\u003cbr\u003e• Insulation: \u003c\/strong\u003e220 Mils Tree Retardant Cross Linked Polyethylene 133% insulation level\u003cstrong\u003e\u003cbr\u003e•  Insulation Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eStrippable semi-conducting cross-linked copolymer\u003cstrong\u003e\u003cbr\u003e• Concentric Shield: \u003c\/strong\u003eConcentrically applied copper bond \/ shield wires. Complies with greater than the minimum requirement as per Table 44, CSA Standard C68.10 and Table 16A, Canadian Electrical Code Part 1\u003cstrong\u003e\u003cbr\u003e•  Neutral Separator:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMylar tape\u003cstrong\u003e\u003cbr\u003e•  Inner Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ePVC inner jacket\u003cstrong\u003e\u003cbr\u003e• Armour: \u003c\/strong\u003eAluminum Interlocked Armour (AIA)\u003cstrong\u003e\u003cbr\u003e• Overall Jacket: \u003c\/strong\u003eRed Polyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA C22.2 No. 174 Cables in Hazardous Locations\u003cbr\u003e• CSA C22.2 No. 2556 \u0026amp; No. 0.3 Wire and Cable Test Methods\u003cbr\u003e• CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV\u003cbr\u003e• CSA C68.3 Shielded \u0026amp; Concentric Neutral Power Cable - 5 to 46 kV\u003cbr\u003e• CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating\u003cbr\u003e• CSA HL - for Hazardous Locations rating\u003cbr\u003e• CSA SUN RES - for Sunlight Resistant rating\u003cbr\u003e• ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable\u003cbr\u003e• ICEA T-29-520 Flame Test (210,000 BTU\/Hr)\u003cbr\u003e• IEEE 383 Flame Test (70,000 btu)\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test (1\/0 and Larger)\u003cbr\u003e• FT1 Flame Test (1,706 BTU\/Hr nominal - Vertical Wire Flame Test)\u003cbr\u003e• AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2\/0 AWG\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e  19\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor (inch):\u003c\/strong\u003e  0.405\u003cbr\u003e\u003cstrong\u003e• Diameter Over Insulation (inch):\u003c\/strong\u003e   0.883\u003cbr\u003e\u003cstrong\u003e• Insul. Thickness mil: \u003c\/strong\u003e220\u003cbr\u003e\u003cstrong\u003e• Diameter Over Insulation Shield (inch):  \u003c\/strong\u003e0.943\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral No. x AWG: \u003c\/strong\u003e11x14\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003cstrong\u003e• Inner Jacket Thickness (mil):\u003c\/strong\u003e   80\u003cbr\u003e\u003cstrong\u003e• Diameter Over Armor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e  1.563\u003cbr\u003e\u003cstrong\u003e• Overall Jacket Thickness mil :\u003c\/strong\u003e 60\u003cbr\u003e\u003cstrong\u003e• Approx. OD inch :  \u003c\/strong\u003e1.683\u003cbr\u003e\u003cstrong\u003e• Copper Weight lb\/1000ft:  \u003c\/strong\u003e559\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e  1432\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e   20.2\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C Ω \/1000ft:\u003c\/strong\u003e  0.081\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°Ω \/1000ft:\u003c\/strong\u003e   0.102\u003cbr\u003e\u003cstrong\u003e• Inductive Reactance @ 60HzΩ\/1000ft:\u003c\/strong\u003e  0.054 \u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity In Air 90°C Amp: \u003c\/strong\u003e  317\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity Directly Buried 90°C Amp:  \u003c\/strong\u003e306\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55761687183729,"sku":"NNC12024","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/16_f72b948d-dd21-4d53-bb01-b9600d6944db.png?v=1756372294"},{"product_id":"3-0-awg-hvteck-copper-220-mil-trxlpe-cb-aia-15kv-133-il-red-pvc-jacket-csa","title":"3\/0 AWG HVTECK Copper 220 mil TRXLPE CB AIA 15KV 133% IL Red PVC Jacket CSA","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC26316_1.pdf?v=1756371899\" width=\"\" height=\"\" type=\"application\/pdf\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e3\/0 AWG HVTECK Copper 220 mil TRXLPE CB AIA 15KV 133% IL Red PVC Jacket CSA\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 15kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications. Rated FT4, -40°C, Hazardous Locations (HL). These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lbs \/FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids and are flame retardant.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e3\/0 AWG HVTECK Copper 1\/C 15kV TRXLPE cable, 220 mil TRXLPE 15kV copper wire, HVTECK 15kV red PVC jacket wire, 15kV TRXLPE copper cable CSA, 3\/0 AWG 220 mil TRXLPE copper wire 15kV, Copper 1\/C 15kV TRXLPE insulated wire, 15kV 133% IL copper wire CSA, HVTECK TRXLPE AIA 15kV cable, Red PVC jacketed 15kV copper wire, 3\/0 AWG HVTECK 220 mil TRXLPE 15kV cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and ASTM B8\u003cstrong\u003e\u003cbr\u003e• Conductor Shield: \u003c\/strong\u003eSemi-conducting cross-linked copolymer\u003cstrong\u003e\u003cbr\u003e• Insulation: \u003c\/strong\u003e220 Mils Tree Retardant Cross Linked Polyethylene 133% insulation level\u003cstrong\u003e\u003cbr\u003e•  Insulation Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eStrippable semi-conducting cross-linked copolymer\u003cstrong\u003e\u003cbr\u003e• Concentric Shield: \u003c\/strong\u003eConcentrically applied copper bond \/ shield wires. Complies with greater than the minimum requirement as per Table 44, CSA Standard C68.10 and Table 16A, Canadian Electrical Code Part 1\u003cstrong\u003e\u003cbr\u003e•  Neutral Separator:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMylar tape\u003cstrong\u003e\u003cbr\u003e•  Inner Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ePVC inner jacket\u003cstrong\u003e\u003cbr\u003e• Armour: \u003c\/strong\u003eAluminum Interlocked Armour (AIA)\u003cstrong\u003e\u003cbr\u003e• Overall Jacket: \u003c\/strong\u003eRed Polyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA C22.2 No. 174 Cables in Hazardous Locations\u003cbr\u003e• CSA C22.2 No. 2556 \u0026amp; No. 0.3 Wire and Cable Test Methods\u003cbr\u003e• CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV\u003cbr\u003e• CSA C68.3 Shielded \u0026amp; Concentric Neutral Power Cable - 5 to 46 kV\u003cbr\u003e• CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating\u003cbr\u003e• CSA HL - for Hazardous Locations rating\u003cbr\u003e• CSA SUN RES - for Sunlight Resistant rating\u003cbr\u003e• ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable\u003cbr\u003e• ICEA T-29-520 Flame Test (210,000 BTU\/Hr)\u003cbr\u003e• IEEE 383 Flame Test (70,000 btu)\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test (1\/0 and Larger)\u003cbr\u003e• FT1 Flame Test (1,706 BTU\/Hr nominal - Vertical Wire Flame Test)\u003cbr\u003e• AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 3\/0 AWG\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e  19\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor (inch):\u003c\/strong\u003e  0.456\u003cbr\u003e\u003cstrong\u003e• Diameter Over Insulation (inch):\u003c\/strong\u003e    0.934\u003cbr\u003e\u003cstrong\u003e• Insul. Thickness mil: \u003c\/strong\u003e220\u003cbr\u003e\u003cstrong\u003e• Diameter Over Insulation Shield (inch):  \u003c\/strong\u003e0.994\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral No. x AWG: \u003c\/strong\u003e13x14\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003cstrong\u003e• Inner Jacket Thickness (mil):\u003c\/strong\u003e   80\u003cbr\u003e\u003cstrong\u003e• Diameter Over Armor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e  1.614\u003cbr\u003e\u003cstrong\u003e• Overall Jacket Thickness mil :\u003c\/strong\u003e 60\u003cbr\u003e\u003cstrong\u003e• Approx. OD inch :  \u003c\/strong\u003e1.734\u003cbr\u003e\u003cstrong\u003e• Copper Weight lb\/1000ft:  \u003c\/strong\u003e694\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e  1612\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e   20.8\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C Ω \/1000ft:\u003c\/strong\u003e  0.064\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°Ω \/1000ft:\u003c\/strong\u003e   0.081 \u003cbr\u003e\u003cstrong\u003e• Inductive Reactance @ 60HzΩ\/1000ft:\u003c\/strong\u003e  0.052\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity In Air 90°C Amp: \u003c\/strong\u003e  357\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity Directly Buried 90°C Amp:  \u003c\/strong\u003e335\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55761729388913,"sku":"NNC12025","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/16_f72b948d-dd21-4d53-bb01-b9600d6944db.png?v=1756372294"},{"product_id":"4-0-awg-hvteck-copper-220-mil-trxlpe-cb-aia-15kv-133-il-red-pvc-jacket-csa","title":"4\/0 AWG HVTECK Copper 220 mil TRXLPE CB AIA 15KV 133% IL Red PVC Jacket CSA","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC26316_1.pdf?v=1756371899\" width=\"\" height=\"\" type=\"application\/pdf\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e4\/0 AWG HVTECK Copper 220 mil TRXLPE CB AIA 15KV 133% IL Red PVC Jacket CSA\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 15kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications. Rated FT4, -40°C, Hazardous Locations (HL). These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lbs \/FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids and are flame retardant.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e4\/0 AWG HVTECK Copper 1\/C 15kV TRXLPE cable, 220 mil TRXLPE 15kV copper wire, HVTECK 15kV red PVC jacket wire, 15kV TRXLPE copper cable CSA, 4\/0 AWG 220 mil TRXLPE copper wire 15kV, Copper 1\/C 15kV TRXLPE insulated wire, 15kV 133% IL copper wire CSA, HVTECK TRXLPE AIA 15kV cable, Red PVC jacketed 15kV copper wire, 4\/0 AWG HVTECK 220 mil TRXLPE 15kV cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and ASTM B8\u003cstrong\u003e\u003cbr\u003e• Conductor Shield: \u003c\/strong\u003eSemi-conducting cross-linked copolymer\u003cstrong\u003e\u003cbr\u003e• Insulation: \u003c\/strong\u003e220 Mils Tree Retardant Cross Linked Polyethylene 133% insulation level\u003cstrong\u003e\u003cbr\u003e•  Insulation Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eStrippable semi-conducting cross-linked copolymer\u003cstrong\u003e\u003cbr\u003e• Concentric Shield: \u003c\/strong\u003eConcentrically applied copper bond \/ shield wires. Complies with greater than the minimum requirement as per Table 44, CSA Standard C68.10 and Table 16A, Canadian Electrical Code Part 1\u003cstrong\u003e\u003cbr\u003e•  Neutral Separator:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMylar tape\u003cstrong\u003e\u003cbr\u003e•  Inner Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ePVC inner jacket\u003cstrong\u003e\u003cbr\u003e• Armour: \u003c\/strong\u003eAluminum Interlocked Armour (AIA)\u003cstrong\u003e\u003cbr\u003e• Overall Jacket: \u003c\/strong\u003eRed Polyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA C22.2 No. 174 Cables in Hazardous Locations\u003cbr\u003e• CSA C22.2 No. 2556 \u0026amp; No. 0.3 Wire and Cable Test Methods\u003cbr\u003e• CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV\u003cbr\u003e• CSA C68.3 Shielded \u0026amp; Concentric Neutral Power Cable - 5 to 46 kV\u003cbr\u003e• CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating\u003cbr\u003e• CSA HL - for Hazardous Locations rating\u003cbr\u003e• CSA SUN RES - for Sunlight Resistant rating\u003cbr\u003e• ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable\u003cbr\u003e• ICEA T-29-520 Flame Test (210,000 BTU\/Hr)\u003cbr\u003e• IEEE 383 Flame Test (70,000 btu)\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test (1\/0 and Larger)\u003cbr\u003e• FT1 Flame Test (1,706 BTU\/Hr nominal - Vertical Wire Flame Test)\u003cbr\u003e• AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 4\/0 AWG\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e  19\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor (inch):\u003c\/strong\u003e  0.512\u003cbr\u003e\u003cstrong\u003e• Diameter Over Insulation (inch):\u003c\/strong\u003e   0.990 \u003cbr\u003e\u003cstrong\u003e• Insul. Thickness mil: \u003c\/strong\u003e220\u003cbr\u003e\u003cstrong\u003e• Diameter Over Insulation Shield (inch):  \u003c\/strong\u003e1.050\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral No. x AWG: \u003c\/strong\u003e13x14\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003cstrong\u003e• Inner Jacket Thickness (mil):\u003c\/strong\u003e   80\u003cbr\u003e\u003cstrong\u003e• Diameter Over Armor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e  1.694\u003cbr\u003e\u003cstrong\u003e• Overall Jacket Thickness mil :\u003c\/strong\u003e 60\u003cbr\u003e\u003cstrong\u003e• Approx. OD inch :  \u003c\/strong\u003e1.814\u003cbr\u003e\u003cstrong\u003e• Copper Weight lb\/1000ft:  \u003c\/strong\u003e829\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e 1829\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e   21.8\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C Ω \/1000ft:\u003c\/strong\u003e  0.051\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°Ω \/1000ft:\u003c\/strong\u003e   0.065\u003cbr\u003e\u003cstrong\u003e• Inductive Reactance @ 60HzΩ\/1000ft:\u003c\/strong\u003e  0.051 \u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity In Air 90°C Amp: \u003c\/strong\u003e 404\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity Directly Buried 90°C Amp:  \u003c\/strong\u003e369\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55761775165809,"sku":"NNC12026","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/16_f72b948d-dd21-4d53-bb01-b9600d6944db.png?v=1756372294"},{"product_id":"250-mcm-hvteck-copper-220-mil-trxlpe-cb-aia-15kv-133-il-red-pvc-jacket-csa","title":"250 MCM HVTECK Copper 220 mil TRXLPE CB AIA 15KV 133% IL Red PVC Jacket CSA","description":"\u003cp\u003e[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC26316_1.pdf?v=1756371899\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e250 MCM HVTECK Copper 220 mil TRXLPE CB AIA 15KV 133% IL Red PVC Jacket CSA\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 15kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications. Rated FT4, -40°C, Hazardous Locations (HL). These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lbs \/FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids and are flame retardant.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e250 MCM HVTECK Copper 1\/C 15kV TRXLPE cable, 220 mil TRXLPE 15kV copper wire, HVTECK 15kV red PVC jacket wire, 15kV TRXLPE copper cable CSA, 250 MCM 220 mil TRXLPE copper wire 15kV, Copper 1\/C 15kV TRXLPE insulated wire, 15kV 133% IL copper wire CSA, HVTECK TRXLPE AIA 15kV cable, Red PVC jacketed 15kV copper wire, 250 MCM HVTECK 220 mil TRXLPE 15kV cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and ASTM B8\u003cstrong\u003e\u003cbr\u003e• Conductor Shield: \u003c\/strong\u003eSemi-conducting cross-linked copolymer\u003cstrong\u003e\u003cbr\u003e• Insulation: \u003c\/strong\u003e220 Mils Tree Retardant Cross Linked Polyethylene 133% insulation level\u003cstrong\u003e\u003cbr\u003e•  Insulation Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eStrippable semi-conducting cross-linked copolymer\u003cstrong\u003e\u003cbr\u003e• Concentric Shield: \u003c\/strong\u003eConcentrically applied copper bond \/ shield wires. Complies with greater than the minimum requirement as per Table 44, CSA Standard C68.10 and Table 16A, Canadian Electrical Code Part 1\u003cstrong\u003e\u003cbr\u003e•  Neutral Separator:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMylar tape\u003cstrong\u003e\u003cbr\u003e•  Inner Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ePVC inner jacket\u003cstrong\u003e\u003cbr\u003e• Armour: \u003c\/strong\u003eAluminum Interlocked Armour (AIA)\u003cstrong\u003e\u003cbr\u003e• Overall Jacket: \u003c\/strong\u003eRed Polyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA C22.2 No. 174 Cables in Hazardous Locations\u003cbr\u003e• CSA C22.2 No. 2556 \u0026amp; No. 0.3 Wire and Cable Test Methods\u003cbr\u003e• CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV\u003cbr\u003e• CSA C68.3 Shielded \u0026amp; Concentric Neutral Power Cable - 5 to 46 kV\u003cbr\u003e• CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating\u003cbr\u003e• CSA HL - for Hazardous Locations rating\u003cbr\u003e• CSA SUN RES - for Sunlight Resistant rating\u003cbr\u003e• ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable\u003cbr\u003e• ICEA T-29-520 Flame Test (210,000 BTU\/Hr)\u003cbr\u003e• IEEE 383 Flame Test (70,000 btu)\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test (1\/0 and Larger)\u003cbr\u003e• FT1 Flame Test (1,706 BTU\/Hr nominal - Vertical Wire Flame Test)\u003cbr\u003e• AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 250 MCM\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e  37\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor (inch):\u003c\/strong\u003e   0.558\u003cbr\u003e\u003cstrong\u003e• Diameter Over Insulation (inch):\u003c\/strong\u003e   1.044\u003cbr\u003e\u003cstrong\u003e• Insul. Thickness mil: \u003c\/strong\u003e220\u003cbr\u003e\u003cstrong\u003e• Diameter Over Insulation Shield (inch):  \u003c\/strong\u003e1.104\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral No. x AWG:  \u003c\/strong\u003e17x14\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003cstrong\u003e• Inner Jacket Thickness (mil):\u003c\/strong\u003e   80\u003cbr\u003e\u003cstrong\u003e• Diameter Over Armor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e  1.748\u003cbr\u003e\u003cstrong\u003e• Overall Jacket Thickness mil :\u003c\/strong\u003e 60\u003cbr\u003e\u003cstrong\u003e• Approx. OD inch :  \u003c\/strong\u003e1.868\u003cbr\u003e\u003cstrong\u003e• Copper Weight lb\/1000ft:  \u003c\/strong\u003e1001\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e 2055\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e   22.4\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C Ω \/1000ft:\u003c\/strong\u003e  0.043\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°Ω \/1000ft:\u003c\/strong\u003e   0.056\u003cbr\u003e\u003cstrong\u003e• Inductive Reactance @ 60HzΩ\/1000ft:\u003c\/strong\u003e  0.049\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity In Air 90°C Amp: \u003c\/strong\u003e 456\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity Directly Buried 90°C Amp:  \u003c\/strong\u003e412\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55761792041329,"sku":"NNC12027","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/16_f72b948d-dd21-4d53-bb01-b9600d6944db.png?v=1756372294"},{"product_id":"350-mcm-hvteck-copper-220-mil-trxlpe-cb-aia-15kv-133-il-red-pvc-jacket-csa","title":"350 MCM HVTECK Copper 220 mil TRXLPE CB AIA 15KV 133% IL Red PVC Jacket CSA","description":"\u003cp\u003e[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC26316_1.pdf?v=1756371899\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e350 MCM HVTECK Copper 220 mil TRXLPE CB AIA 15KV 133% IL Red PVC Jacket CSA\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 15kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications. Rated FT4, -40°C, Hazardous Locations (HL). These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lbs \/FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids and are flame retardant.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e350 MCM HVTECK Copper 1\/C 15kV TRXLPE cable, 220 mil TRXLPE 15kV copper wire, HVTECK 15kV red PVC jacket wire, 15kV TRXLPE copper cable CSA, 350 MCM 220 mil TRXLPE copper wire 15kV, Copper 1\/C 15kV TRXLPE insulated wire, 15kV 133% IL copper wire CSA, HVTECK TRXLPE AIA 15kV cable, Red PVC jacketed 15kV copper wire, 350 MCM HVTECK 220 mil TRXLPE 15kV cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and ASTM B8\u003cstrong\u003e\u003cbr\u003e• Conductor Shield: \u003c\/strong\u003eSemi-conducting cross-linked copolymer\u003cstrong\u003e\u003cbr\u003e• Insulation: \u003c\/strong\u003e220 Mils Tree Retardant Cross Linked Polyethylene 133% insulation level\u003cstrong\u003e\u003cbr\u003e•  Insulation Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eStrippable semi-conducting cross-linked copolymer\u003cstrong\u003e\u003cbr\u003e• Concentric Shield: \u003c\/strong\u003eConcentrically applied copper bond \/ shield wires. Complies with greater than the minimum requirement as per Table 44, CSA Standard C68.10 and Table 16A, Canadian Electrical Code Part 1\u003cstrong\u003e\u003cbr\u003e•  Neutral Separator:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMylar tape\u003cstrong\u003e\u003cbr\u003e•  Inner Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ePVC inner jacket\u003cstrong\u003e\u003cbr\u003e• Armour: \u003c\/strong\u003eAluminum Interlocked Armour (AIA)\u003cstrong\u003e\u003cbr\u003e• Overall Jacket: \u003c\/strong\u003eRed Polyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA C22.2 No. 174 Cables in Hazardous Locations\u003cbr\u003e• CSA C22.2 No. 2556 \u0026amp; No. 0.3 Wire and Cable Test Methods\u003cbr\u003e• CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV\u003cbr\u003e• CSA C68.3 Shielded \u0026amp; Concentric Neutral Power Cable - 5 to 46 kV\u003cbr\u003e• CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating\u003cbr\u003e• CSA HL - for Hazardous Locations rating\u003cbr\u003e• CSA SUN RES - for Sunlight Resistant rating\u003cbr\u003e• ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable\u003cbr\u003e• ICEA T-29-520 Flame Test (210,000 BTU\/Hr)\u003cbr\u003e• IEEE 383 Flame Test (70,000 btu)\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test (1\/0 and Larger)\u003cbr\u003e• FT1 Flame Test (1,706 BTU\/Hr nominal - Vertical Wire Flame Test)\u003cbr\u003e• AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 350 MCM\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e  37\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor (inch):\u003c\/strong\u003e  0.661\u003cbr\u003e\u003cstrong\u003e• Diameter Over Insulation (inch):\u003c\/strong\u003e 1.147\u003cbr\u003e\u003cstrong\u003e• Insul. Thickness mil: \u003c\/strong\u003e220\u003cbr\u003e\u003cstrong\u003e• Diameter Over Insulation Shield (inch):  \u003c\/strong\u003e1.207\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral No. x AWG: \u003c\/strong\u003e 21x14\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003cstrong\u003e• Inner Jacket Thickness (mil):\u003c\/strong\u003e   80\u003cbr\u003e\u003cstrong\u003e• Diameter Over Armor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e  1.885\u003cbr\u003e\u003cstrong\u003e• Overall Jacket Thickness mil :\u003c\/strong\u003e 60\u003cbr\u003e\u003cstrong\u003e• Approx. OD inch : \u003c\/strong\u003e2.005\u003cbr\u003e\u003cstrong\u003e• Copper Weight lb\/1000ft:  \u003c\/strong\u003e1365\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e 2620\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e   24.1\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C Ω \/1000ft:\u003c\/strong\u003e  0.031\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°Ω \/1000ft:\u003c\/strong\u003e   0.041\u003cbr\u003e\u003cstrong\u003e• Inductive Reactance @ 60HzΩ\/1000ft:\u003c\/strong\u003e  0.047\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity In Air 90°C Amp: \u003c\/strong\u003e 537\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity Directly Buried 90°C Amp:  \u003c\/strong\u003e456\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55761806852465,"sku":"NNC12028","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/16_f72b948d-dd21-4d53-bb01-b9600d6944db.png?v=1756372294"},{"product_id":"500-mcm-hvteck-copper-220-mil-trxlpe-cb-aia-15kv-133-il-red-pvc-jacket-csa","title":"500 MCM HVTECK Copper 220 mil TRXLPE CB AIA 15KV 133% IL Red PVC Jacket CSA","description":"\u003cp\u003e[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC26316_1.pdf?v=1756371899\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e500 MCM HVTECK Copper 220 mil TRXLPE CB AIA 15KV 133% IL Red PVC Jacket CSA\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 15kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications. Rated FT4, -40°C, Hazardous Locations (HL). These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lbs \/FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids and are flame retardant.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e500 MCM HVTECK Copper 1\/C 15kV TRXLPE cable, 220 mil TRXLPE 15kV copper wire, HVTECK 15kV red PVC jacket wire, 15kV TRXLPE copper cable CSA, 500 MCM 220 mil TRXLPE copper wire 15kV, Copper 1\/C 15kV TRXLPE insulated wire, 15kV 133% IL copper wire CSA, HVTECK TRXLPE AIA 15kV cable, Red PVC jacketed 15kV copper wire, 500 MCM HVTECK 220 mil TRXLPE 15kV cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and ASTM B8\u003cstrong\u003e\u003cbr\u003e• Conductor Shield: \u003c\/strong\u003eSemi-conducting cross-linked copolymer\u003cstrong\u003e\u003cbr\u003e• Insulation: \u003c\/strong\u003e220 Mils Tree Retardant Cross Linked Polyethylene 133% insulation level\u003cstrong\u003e\u003cbr\u003e•  Insulation Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eStrippable semi-conducting cross-linked copolymer\u003cstrong\u003e\u003cbr\u003e• Concentric Shield: \u003c\/strong\u003eConcentrically applied copper bond \/ shield wires. Complies with greater than the minimum requirement as per Table 44, CSA Standard C68.10 and Table 16A, Canadian Electrical Code Part 1\u003cstrong\u003e\u003cbr\u003e•  Neutral Separator:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMylar tape\u003cstrong\u003e\u003cbr\u003e•  Inner Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ePVC inner jacket\u003cstrong\u003e\u003cbr\u003e• Armour: \u003c\/strong\u003eAluminum Interlocked Armour (AIA)\u003cstrong\u003e\u003cbr\u003e• Overall Jacket: \u003c\/strong\u003eRed Polyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA C22.2 No. 174 Cables in Hazardous Locations\u003cbr\u003e• CSA C22.2 No. 2556 \u0026amp; No. 0.3 Wire and Cable Test Methods\u003cbr\u003e• CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV\u003cbr\u003e• CSA C68.3 Shielded \u0026amp; Concentric Neutral Power Cable - 5 to 46 kV\u003cbr\u003e• CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating\u003cbr\u003e• CSA HL - for Hazardous Locations rating\u003cbr\u003e• CSA SUN RES - for Sunlight Resistant rating\u003cbr\u003e• ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable\u003cbr\u003e• ICEA T-29-520 Flame Test (210,000 BTU\/Hr)\u003cbr\u003e• IEEE 383 Flame Test (70,000 btu)\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test (1\/0 and Larger)\u003cbr\u003e• FT1 Flame Test (1,706 BTU\/Hr nominal - Vertical Wire Flame Test)\u003cbr\u003e• AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 500 MCM\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e  37\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor (inch):\u003c\/strong\u003e   0.789\u003cbr\u003e\u003cstrong\u003e• Diameter Over Insulation (inch):\u003c\/strong\u003e  1.275\u003cbr\u003e\u003cstrong\u003e• Insul. Thickness mil: \u003c\/strong\u003e220\u003cbr\u003e\u003cstrong\u003e• Diameter Over Insulation Shield (inch):  \u003c\/strong\u003e1.335\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral No. x AWG: \u003c\/strong\u003e 26x14\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003cstrong\u003e• Inner Jacket Thickness (mil):\u003c\/strong\u003e   80\u003cbr\u003e\u003cstrong\u003e• Diameter Over Armor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e  1.973\u003cbr\u003e\u003cstrong\u003e• Overall Jacket Thickness mil :\u003c\/strong\u003e 60\u003cbr\u003e\u003cstrong\u003e• Approx. OD inch : \u003c\/strong\u003e2.093\u003cbr\u003e\u003cstrong\u003e• Copper Weight lb\/1000ft:  \u003c\/strong\u003e1863\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e 3118\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e  25.1\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C Ω \/1000ft:\u003c\/strong\u003e   0.022\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°Ω \/1000ft:\u003c\/strong\u003e   0.030\u003cbr\u003e\u003cstrong\u003e• Inductive Reactance @ 60HzΩ\/1000ft:\u003c\/strong\u003e  0.044\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity In Air 90°C Amp: \u003c\/strong\u003e  616\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity Directly Buried 90°C Amp:  \u003c\/strong\u003e497\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 325.114px; height: 35.5966px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e672982\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55761815470449,"sku":"NNC672982","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/16_f72b948d-dd21-4d53-bb01-b9600d6944db.png?v=1756372294"},{"product_id":"750-mcm-hvteck-copper-220-mil-trxlpe-cb-aia-15kv-133-il-red-pvc-jacket-csa","title":"750 MCM HVTECK Copper 220 mil TRXLPE CB AIA 15KV 133% IL Red PVC Jacket CSA","description":"\u003cp\u003e[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC26316_1.pdf?v=1756371899\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e750 MCM HVTECK Copper 220 mil TRXLPE CB AIA 15KV 133% IL Red PVC Jacket CSA\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 15kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications. Rated FT4, -40°C, Hazardous Locations (HL). These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lbs \/FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids and are flame retardant.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e750 MCM HVTECK Copper 1\/C 15kV TRXLPE cable, 220 mil TRXLPE 15kV copper wire, HVTECK 15kV red PVC jacket wire, 15kV TRXLPE copper cable CSA, 750 MCM 220 mil TRXLPE copper wire 15kV, Copper 1\/C 15kV TRXLPE insulated wire, 15kV 133% IL copper wire CSA, HVTECK TRXLPE AIA 15kV cable, Red PVC jacketed 15kV copper wire, 750 MCM HVTECK 220 mil TRXLPE 15kV cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and ASTM B8\u003cstrong\u003e\u003cbr\u003e• Conductor Shield: \u003c\/strong\u003eSemi-conducting cross-linked copolymer\u003cstrong\u003e\u003cbr\u003e• Insulation: \u003c\/strong\u003e220 Mils Tree Retardant Cross Linked Polyethylene 133% insulation level\u003cstrong\u003e\u003cbr\u003e•  Insulation Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eStrippable semi-conducting cross-linked copolymer\u003cstrong\u003e\u003cbr\u003e• Concentric Shield: \u003c\/strong\u003eConcentrically applied copper bond \/ shield wires. Complies with greater than the minimum requirement as per Table 44, CSA Standard C68.10 and Table 16A, Canadian Electrical Code Part 1\u003cstrong\u003e\u003cbr\u003e•  Neutral Separator:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMylar tape\u003cstrong\u003e\u003cbr\u003e•  Inner Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ePVC inner jacket\u003cstrong\u003e\u003cbr\u003e• Armour: \u003c\/strong\u003eAluminum Interlocked Armour (AIA)\u003cstrong\u003e\u003cbr\u003e• Overall Jacket: \u003c\/strong\u003eRed Polyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA C22.2 No. 174 Cables in Hazardous Locations\u003cbr\u003e• CSA C22.2 No. 2556 \u0026amp; No. 0.3 Wire and Cable Test Methods\u003cbr\u003e• CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV\u003cbr\u003e• CSA C68.3 Shielded \u0026amp; Concentric Neutral Power Cable - 5 to 46 kV\u003cbr\u003e• CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating\u003cbr\u003e• CSA HL - for Hazardous Locations rating\u003cbr\u003e• CSA SUN RES - for Sunlight Resistant rating\u003cbr\u003e• ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable\u003cbr\u003e• ICEA T-29-520 Flame Test (210,000 BTU\/Hr)\u003cbr\u003e• IEEE 383 Flame Test (70,000 btu)\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test (1\/0 and Larger)\u003cbr\u003e• FT1 Flame Test (1,706 BTU\/Hr nominal - Vertical Wire Flame Test)\u003cbr\u003e• AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 750 MCM\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 61\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor (inch):\u003c\/strong\u003e   0.968\u003cbr\u003e\u003cstrong\u003e• Diameter Over Insulation (inch):\u003c\/strong\u003e  1.464\u003cbr\u003e\u003cstrong\u003e• Insul. Thickness mil: \u003c\/strong\u003e220\u003cbr\u003e\u003cstrong\u003e• Diameter Over Insulation Shield (inch):  \u003c\/strong\u003e1.524\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral No. x AWG: \u003c\/strong\u003e 21x12\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003cstrong\u003e• Inner Jacket Thickness (mil):\u003c\/strong\u003e  110\u003cbr\u003e\u003cstrong\u003e• Diameter Over Armor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e  2.222\u003cbr\u003e\u003cstrong\u003e• Overall Jacket Thickness mil :\u003c\/strong\u003e  75\u003cbr\u003e\u003cstrong\u003e• Approx. OD inch : \u003c\/strong\u003e2.342\u003cbr\u003e\u003cstrong\u003e• Copper Weight lb\/1000ft:  \u003c\/strong\u003e2715\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e 4258\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e  28.1\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C Ω \/1000ft:\u003c\/strong\u003e   0.014\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°Ω \/1000ft:\u003c\/strong\u003e   0.023\u003cbr\u003e\u003cstrong\u003e• Inductive Reactance @ 60HzΩ\/1000ft:\u003c\/strong\u003e  0.042\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity In Air 90°C Amp: \u003c\/strong\u003e   706\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity Directly Buried 90°C Amp:  \u003c\/strong\u003e551\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 325.114px; height: 35.5966px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e668996\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55761823760753,"sku":"NNC668996","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/16_f72b948d-dd21-4d53-bb01-b9600d6944db.png?v=1756372294"},{"product_id":"1000-mcm-hvteck-copper-220-mil-trxlpe-cb-aia-15kv-133-il-red-pvc-jacket-csa","title":"1000 MCM HVTECK Copper 220 mil TRXLPE CB AIA 15KV 133% IL Red PVC Jacket CSA","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC26316_1.pdf?v=1756371899\" width=\"\" height=\"\" type=\"application\/pdf\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1000 MCM HVTECK Copper 220 mil TRXLPE CB AIA 15KV 133% IL Red PVC Jacket CSA\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 15kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications. Rated FT4, -40°C, Hazardous Locations (HL). These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lbs \/FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids and are flame retardant.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1000  MCM HVTECK Copper 1\/C 15kV TRXLPE cable, 220 mil TRXLPE 15kV copper wire, HVTECK 15kV red PVC jacket wire, 15kV TRXLPE copper cable CSA, 1000 MCM 220 mil TRXLPE copper wire 15kV, Copper 1\/C 15kV TRXLPE insulated wire, 15kV 133% IL copper wire CSA, HVTECK TRXLPE AIA 15kV cable, Red PVC jacketed 15kV copper wire, 1000 MCM HVTECK 220 mil TRXLPE 15kV cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eClass B compressed stranded bare copper per ASTM B3 and ASTM B8\u003cstrong\u003e\u003cbr\u003e• Conductor Shield: \u003c\/strong\u003eSemi-conducting cross-linked copolymer\u003cstrong\u003e\u003cbr\u003e• Insulation: \u003c\/strong\u003e220 Mils Tree Retardant Cross Linked Polyethylene 133% insulation level\u003cstrong\u003e\u003cbr\u003e•  Insulation Shield:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eStrippable semi-conducting cross-linked copolymer\u003cstrong\u003e\u003cbr\u003e• Concentric Shield: \u003c\/strong\u003eConcentrically applied copper bond \/ shield wires. Complies with greater than the minimum requirement as per Table 44, CSA Standard C68.10 and Table 16A, Canadian Electrical Code Part 1\u003cstrong\u003e\u003cbr\u003e•  Neutral Separator:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMylar tape\u003cstrong\u003e\u003cbr\u003e•  Inner Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ePVC inner jacket\u003cstrong\u003e\u003cbr\u003e• Armour: \u003c\/strong\u003eAluminum Interlocked Armour (AIA)\u003cstrong\u003e\u003cbr\u003e• Overall Jacket: \u003c\/strong\u003eRed Polyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• ASTM B3 Soft or Annealed Copper Wire\u003cbr\u003e• ASTM B8 Concentric-Lay-Stranded Copper Conductors\u003cbr\u003e• CSA C22.2 No. 174 Cables in Hazardous Locations\u003cbr\u003e• CSA C22.2 No. 2556 \u0026amp; No. 0.3 Wire and Cable Test Methods\u003cbr\u003e• CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV\u003cbr\u003e• CSA C68.3 Shielded \u0026amp; Concentric Neutral Power Cable - 5 to 46 kV\u003cbr\u003e• CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating\u003cbr\u003e• CSA HL - for Hazardous Locations rating\u003cbr\u003e• CSA SUN RES - for Sunlight Resistant rating\u003cbr\u003e• ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable\u003cbr\u003e• ICEA T-29-520 Flame Test (210,000 BTU\/Hr)\u003cbr\u003e• IEEE 383 Flame Test (70,000 btu)\u003cbr\u003e• IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test (1\/0 and Larger)\u003cbr\u003e• FT1 Flame Test (1,706 BTU\/Hr nominal - Vertical Wire Flame Test)\u003cbr\u003e• AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1000 MCM\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 61\u003cbr\u003e\u003cstrong\u003e• Diameter Over Conductor (inch):\u003c\/strong\u003e   1.117\u003cbr\u003e\u003cstrong\u003e• Diameter Over Insulation (inch):\u003c\/strong\u003e   1.613\u003cbr\u003e\u003cstrong\u003e• Insul. Thickness mil: \u003c\/strong\u003e220\u003cbr\u003e\u003cstrong\u003e• Diameter Over Insulation Shield (inch):  \u003c\/strong\u003e1.673\u003cbr\u003e\u003cstrong\u003e• Concentric Neutral No. x AWG: \u003c\/strong\u003e 21x12\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003cstrong\u003e• Inner Jacket Thickness (mil):\u003c\/strong\u003e  110\u003cbr\u003e\u003cstrong\u003e• Diameter Over Armor\u003c\/strong\u003e \u003cstrong\u003e(inch):\u003c\/strong\u003e   2.369 \u003cbr\u003e\u003cstrong\u003e• Overall Jacket Thickness mil :\u003c\/strong\u003e  75\u003cbr\u003e\u003cstrong\u003e• Approx. OD inch :  \u003c\/strong\u003e2.519\u003cbr\u003e\u003cstrong\u003e• Copper Weight lb\/1000ft:  \u003c\/strong\u003e3527\u003cbr\u003e\u003cstrong\u003e• Approx. Weight (Lbs\/1000'Ft):\u003c\/strong\u003e  5277\u003cbr\u003e\u003cstrong\u003e• Min Bending Radius (In):\u003c\/strong\u003e  30.2\u003cbr\u003e\u003cstrong\u003e• DC Resistance @ 25°C Ω \/1000ft:\u003c\/strong\u003e    0.011\u003cbr\u003e\u003cstrong\u003e• AC Resistance @ 90°Ω \/1000ft:\u003c\/strong\u003e    0.019\u003cbr\u003e\u003cstrong\u003e• Inductive Reactance @ 60HzΩ\/1000ft:\u003c\/strong\u003e  0.040\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity In Air 90°C Amp: \u003c\/strong\u003e  813\u003cbr\u003e\u003cstrong\u003e• Allowable Ampacity Directly Buried 90°C Amp:  \u003c\/strong\u003e596\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 325.114px; height: 35.5966px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e672986\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":55761831559537,"sku":"NNC672986","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/16_f72b948d-dd21-4d53-bb01-b9600d6944db.png?v=1756372294"}],"url":"https:\/\/nassaunationalcable.com\/collections\/hvteck-copper-1-c-220-mil-trxlpe-cb-aia-15kv-133-il-red-pvc-jacket-csa.oembed","provider":"NassauNationalCable","version":"1.0","type":"link"}