{"title":"HVTECK Aluminum 3\/C 220 mil NLEPR TS AIA 15kV 133% IL Red PVC Jacket CSA","description":null,"products":[{"product_id":"2-awg-3c-hvteck-aluminum-220-mil-nlepr-ts-aia-15kv-133-il-red-pvc-jacket-csa-1","title":"2 AWG 3C HVTECK Aluminum 220 mil NLEPR TS AIA 15kV 133% IL Red PVC Jacket CSA","description":"\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e 2 AWG 3C HVTECK Aluminum 220 mil NLEPR TS AIA 15kV 133% IL Red PVC Jacket CSA\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC26362_1.pdf?v=1790838959\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan data-sheets-root=\"1\"\u003eApplication:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan data-sheets-root=\"1\"\u003eThe 15kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications. Rated FT4, -40°C, Hazardous Locations (HL). These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lbs \/FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids and are flame retardant.3 Conductor, 220 Mils No Lead Ethylene Propylene Rubber (NL-EPR), 133% Insulation Level, Tape Shield, Polyvinyl Chloride (PVC) Inner Jacket, Aluminum Interlocked Armour (AIA), Polyvinyl Chloride (PVC) Jacket.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eAlso Known as:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e2 AWG 3C 15kV HVTECK Cable, 2 AWG 3C \u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e15kV HVTECK Armoured Cable, 2 AWG 3C1 5kV CSA Armoured Cable, 2 AWG 3C 15kV Medium Voltage Cable, 2 AWG 3C 15kV MV Cable, 2 AWG 3C 15kV 3\/C Aluminum Cable,2 AWG 3C 3 Conductor 15kV Cable, 2 AWG 3C 3\/C Aluminum HV Cable, 2 AWG 3C 220 mil NLEPR Cable, NL-EPR Insulated Cable, 2 AWG 3C EPR Insulated Medium Voltage Cable, 2-3C Tape Shielded MV Cable, 2-3C Copper Tape Shield Cable, 2-3C AIA Armoured Cable, 2-3C Aluminum Interlocked Armour Cable, 2-3C PVC Inner Jacket Cable, 2-3C PVC Jacketed Armoured Cable, 2-3C 15kV Shielded Power Cable, 2-3C CSA 15kV Power Cable, 2-3C Hazardous Location 15kV Cable, 2-3C FT4 15kV Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Class B compact stranded 8000 Series aluminum per ASTM B800 and ASTM B836\u003cbr\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi-conducting cross-linked copolymer; A conductor separator is used for cable size larger than or equal to 500 Kcmil\u003cbr\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e 220 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% insulation level\u003cbr\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Strippable semi-conducting cross-linked copolymer\u003cbr\u003e \u003cstrong\u003eCopper Tape Shield:\u003c\/strong\u003e Helically wrapped 5 mil copper tape with 25% overlap\u003cbr\u003e \u003cstrong\u003eFiller:\u003c\/strong\u003e Interstices filled with non-hydroscoping\/non-wicking fillers\u003cbr\u003e \u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e Class B compressed stranded bare copper ground per ASTM B3 and ASTM B8\u003cbr\u003e \u003cstrong\u003eBinder:\u003c\/strong\u003e Polypropylene tape\u003cbr\u003e \u003cstrong\u003eInner Jacket:\u003c\/strong\u003e PVC inner jacket\u003cbr\u003e \u003cstrong\u003eArmour:\u003c\/strong\u003e Aluminum Interlocked Armour (AIA)\u003cbr\u003e \u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e Red Polyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e ASTM B801 Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy\u003cbr\u003e ASTM B836 Compact Rounded Stranded Aluminum Conductors\u003cbr\u003e CSA C22.2 No. 174 Cables in Hazardous Locations\u003cbr\u003e CSA C22.2 No. 2556 \u0026amp; No. 0.3 Wire and Cable Test Methods\u003cbr\u003e CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV\u003cbr\u003e CSA C68.3 Shielded \u0026amp; Concentric Neutral Power Cable - 5 to 46 kV\u003cbr\u003e CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating\u003cbr\u003e CSA HL - for Hazardous Locations rating\u003cbr\u003e CSA SUN RES - for Sunlight Resistant rating\u003cbr\u003e ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable\u003cbr\u003e ICEA T-29-520 Flame Test (210,000 BTU\/Hr)\u003cbr\u003e IEEE 383 Flame Test (70,000 btu)\u003cbr\u003e IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003cbr\u003e FT1 Flame Test (1,706 BTU\/Hr nominal - Vertical Wire Flame Test)\u003cbr\u003e AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements).\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e 2 AWG\u003cbr\u003e\u003cstrong\u003eNo of Strand:\u003c\/strong\u003e 7\u003cbr\u003e\u003cstrong\u003eDiameter Over Conductor:\u003c\/strong\u003e 0.268inch\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation:\u003c\/strong\u003e 0.746inch\u003cbr\u003e\u003cstrong\u003eInsulation Thickness:\u003c\/strong\u003e 220mil\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation Shield:\u003c\/strong\u003e 0.806inch\u003cbr\u003e\u003cstrong\u003eGround Size:\u003c\/strong\u003e 8 AWG\u003cbr\u003e\u003cstrong\u003eInner Jacket Thickness:\u003c\/strong\u003e 110mil\u003cbr\u003e\u003cstrong\u003eDia. Over Armour:\u003c\/strong\u003e 2.360inch\u003cbr\u003e\u003cstrong\u003eOverall Jacket Thickness:\u003c\/strong\u003e  75mil\u003cbr\u003e\u003cstrong\u003eApprox.OD:\u003c\/strong\u003e 2.510inch\u003cbr\u003e\u003cstrong\u003eApprox.Weight(lb\/1000)\u003c\/strong\u003e: 2392\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":67613696590193,"sku":"NNC2587","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitleddesign_1_d538a474-ff80-4bee-bd1d-2905d73cabf0.png?v=1790838400"},{"product_id":"1-awg-3c-19-strands-hvteck-aluminum-220-mil-nlepr-ts-aia-15kv-133-il-red-pvc-jacket-csa-1","title":"1 AWG 3C 19 Strands HVTECK Aluminum 220 mil NLEPR TS AIA 15kV 133% IL Red PVC Jacket CSA","description":"\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e 2 AWG 3C HVTECK Aluminum 220 mil NLEPR TS AIA 15kV 133% IL Red PVC Jacket CSA\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC26362_1.pdf?v=1790838959\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan data-sheets-root=\"1\"\u003eApplication:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan data-sheets-root=\"1\"\u003eThe 15kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications. Rated FT4, -40°C, Hazardous Locations (HL). These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lbs \/FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids and are flame retardant.3 Conductor, 220 Mils No Lead Ethylene Propylene Rubber (NL-EPR), 133% Insulation Level, Tape Shield, Polyvinyl Chloride (PVC) Inner Jacket, Aluminum Interlocked Armour (AIA), Polyvinyl Chloride (PVC) Jacket.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eAlso Known as:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1 AWG 3C 15kV HVTECK Cable, 1 AWG 3C \u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e15kV HVTECK Armoured Cable, 1 AWG 3C 15kV CSA Armoured Cable, 1 AWG 3C 15kV Medium Voltage Cable, 1 AWG 3C 15kV MV Cable,1 AWG 3C 15kV 3\/C Aluminum Cable, 1 AWG 3C3 Conductor 15kV Cable, 1 AWG 3C 3\/C Aluminum HV Cable, 1 AWG 3C 220 mil NLEPR Cable, 1 AWG 3CNL-EPR Insulated Cable, 1 AWG 3C EPR Insulated Medium Voltage Cable, 1-3C Tape Shielded MV Cable, 1-3C Copper Tape Shield Cable, 1-3C AIA Armoured Cable, 1-3C Aluminum Interlocked Armour Cable, 1-3C PVC Inner Jacket Cable, 1-3C PVC Jacketed Armoured Cable, 1-3C 15kV Shielded Power Cable, 1-3C CSA 15kV Power Cable, 1-3C Hazardous Location 15kV Cable, 1-3C FT4 15kV Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Class B compact stranded 8000 Series aluminum per ASTM B800 and ASTM B836\u003cbr\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi-conducting cross-linked copolymer; A conductor separator is used for cable size larger than or equal to 500 Kcmil\u003cbr\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e 220 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% insulation level\u003cbr\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Strippable semi-conducting cross-linked copolymer\u003cbr\u003e \u003cstrong\u003eCopper Tape Shield:\u003c\/strong\u003e Helically wrapped 5 mil copper tape with 25% overlap\u003cbr\u003e \u003cstrong\u003eFiller:\u003c\/strong\u003e Interstices filled with non-hydroscoping\/non-wicking fillers\u003cbr\u003e \u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e Class B compressed stranded bare copper ground per ASTM B3 and ASTM B8\u003cbr\u003e \u003cstrong\u003eBinder:\u003c\/strong\u003e Polypropylene tape\u003cbr\u003e \u003cstrong\u003eInner Jacket:\u003c\/strong\u003e PVC inner jacket\u003cbr\u003e \u003cstrong\u003eArmour:\u003c\/strong\u003e Aluminum Interlocked Armour (AIA)\u003cbr\u003e \u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e Red Polyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e ASTM B801 Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy\u003cbr\u003e ASTM B836 Compact Rounded Stranded Aluminum Conductors\u003cbr\u003e CSA C22.2 No. 174 Cables in Hazardous Locations\u003cbr\u003e CSA C22.2 No. 2556 \u0026amp; No. 0.3 Wire and Cable Test Methods\u003cbr\u003e CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV\u003cbr\u003e CSA C68.3 Shielded \u0026amp; Concentric Neutral Power Cable - 5 to 46 kV\u003cbr\u003e CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating\u003cbr\u003e CSA HL - for Hazardous Locations rating\u003cbr\u003e CSA SUN RES - for Sunlight Resistant rating\u003cbr\u003e ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable\u003cbr\u003e ICEA T-29-520 Flame Test (210,000 BTU\/Hr)\u003cbr\u003e IEEE 383 Flame Test (70,000 btu)\u003cbr\u003e IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003cbr\u003e FT1 Flame Test (1,706 BTU\/Hr nominal - Vertical Wire Flame Test)\u003cbr\u003e AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements).\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e 1 AWG\u003cbr\u003e\u003cstrong\u003eNo of Strand:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003eDiameter Over Conductor: \u003c\/strong\u003e0.298inch\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation:\u003c\/strong\u003e 0.776inch\u003cbr\u003e\u003cstrong\u003eInsulation Thickness:\u003c\/strong\u003e 220mil\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation Shield:\u003c\/strong\u003e 0.836inch\u003cbr\u003e\u003cstrong\u003eGround Size:\u003c\/strong\u003e 6 AWG\u003cbr\u003e\u003cstrong\u003eInner Jacket Thickness:\u003c\/strong\u003e 110mil\u003cbr\u003e\u003cstrong\u003eDia. Over Armour:\u003c\/strong\u003e  2.425inch\u003cbr\u003e\u003cstrong\u003eOverall Jacket Thickness:\u003c\/strong\u003e  75mil\u003cbr\u003e\u003cstrong\u003eApprox.OD:\u003c\/strong\u003e  2.575inch\u003cbr\u003e\u003cstrong\u003eApprox.Weight(lb\/1000):\u003c\/strong\u003e 2546\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":67613761536369,"sku":"NNC5612","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitleddesign_1_d538a474-ff80-4bee-bd1d-2905d73cabf0.png?v=1790838400"},{"product_id":"1-awg-3c-8-strands-hvteck-aluminum-220-mil-nlepr-ts-aia-15kv-133-il-red-pvc-jacket-csa","title":"1 AWG 3C 8 Strands HVTECK Aluminum 220 mil NLEPR TS AIA 15kV 133% IL Red PVC Jacket CSA","description":"\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e1 AWG 3C 8 Strands HVTECK Aluminum 220 mil NLEPR TS AIA 15kV 133% IL Red PVC Jacket CSA\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC26362_1.pdf?v=1790838959\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan data-sheets-root=\"1\"\u003eApplication:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan data-sheets-root=\"1\"\u003eThe 15kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications. Rated FT4, -40°C, Hazardous Locations (HL). These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lbs \/FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids and are flame retardant.3 Conductor, 220 Mils No Lead Ethylene Propylene Rubber (NL-EPR), 133% Insulation Level, Tape Shield, Polyvinyl Chloride (PVC) Inner Jacket, Aluminum Interlocked Armour (AIA), Polyvinyl Chloride (PVC) Jacket.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eAlso Known as:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1 AWG 3C 15kV HVTECK Cable, 1 AWG 3C \u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e15kV HVTECK Armoured Cable, 1 AWG 3C 15kV CSA Armoured Cable,1 AWG 3C 15kV Medium Voltage Cable,1 AWG 3C 15kV MV Cable, 1 AWG 3C 15kV 3\/C Aluminum Cable1 AWG 3C 3 Conductor 15kV Cable,1 AWG 3C 3\/C Aluminum HV Cable,1 AWG 3C 220 mil NLEPR Cable,1 AWG 3C NL-EPR Insulated Cable, 1 AWG 3C EPR Insulated Medium Voltage Cable, 1-3C Tape Shielded MV Cable, 1-3C Copper Tape Shield Cable, 1-3C AIA Armoured Cable, 1-3C Aluminum Interlocked Armour Cable, 1-3C PVC Inner Jacket Cable, 1-3C PVC Jacketed Armoured Cable, 1-3C 15kV Shielded Power Cable, 1-3C CSA 15kV Power Cable, 1-3C Hazardous Location 15kV Cable, 1-3C FT4 15kV Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Class B compact stranded 8000 Series aluminum per ASTM B800 and ASTM B836\u003cbr\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi-conducting cross-linked copolymer; A conductor separator is used for cable size larger than or equal to 500 Kcmil\u003cbr\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e 220 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% insulation level\u003cbr\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Strippable semi-conducting cross-linked copolymer\u003cbr\u003e \u003cstrong\u003eCopper Tape Shield:\u003c\/strong\u003e Helically wrapped 5 mil copper tape with 25% overlap\u003cbr\u003e \u003cstrong\u003eFiller:\u003c\/strong\u003e Interstices filled with non-hydroscoping\/non-wicking fillers\u003cbr\u003e \u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e Class B compressed stranded bare copper ground per ASTM B3 and ASTM B8\u003cbr\u003e \u003cstrong\u003eBinder:\u003c\/strong\u003e Polypropylene tape\u003cbr\u003e \u003cstrong\u003eInner Jacket:\u003c\/strong\u003e PVC inner jacket\u003cbr\u003e \u003cstrong\u003eArmour:\u003c\/strong\u003e Aluminum Interlocked Armour (AIA)\u003cbr\u003e \u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e Red Polyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e ASTM B801 Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy\u003cbr\u003e ASTM B836 Compact Rounded Stranded Aluminum Conductors\u003cbr\u003e CSA C22.2 No. 174 Cables in Hazardous Locations\u003cbr\u003e CSA C22.2 No. 2556 \u0026amp; No. 0.3 Wire and Cable Test Methods\u003cbr\u003e CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV\u003cbr\u003e CSA C68.3 Shielded \u0026amp; Concentric Neutral Power Cable - 5 to 46 kV\u003cbr\u003e CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating\u003cbr\u003e CSA HL - for Hazardous Locations rating\u003cbr\u003e CSA SUN RES - for Sunlight Resistant rating\u003cbr\u003e ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable\u003cbr\u003e ICEA T-29-520 Flame Test (210,000 BTU\/Hr)\u003cbr\u003e IEEE 383 Flame Test (70,000 btu)\u003cbr\u003e IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003cbr\u003e FT1 Flame Test (1,706 BTU\/Hr nominal - Vertical Wire Flame Test)\u003cbr\u003e AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements).\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e 1 AWG\u003cbr\u003e\u003cstrong\u003eNo of Strand:\u003c\/strong\u003e 8\u003cbr\u003e\u003cstrong\u003eDiameter Over Conductor:\u003c\/strong\u003e 0.298inch\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation:\u003c\/strong\u003e 0.777inch\u003cbr\u003e\u003cstrong\u003eInsulation Thickness:\u003c\/strong\u003e 220mil\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation Shield:\u003c\/strong\u003e  0.837inch\u003cbr\u003e\u003cstrong\u003eGround Size:\u003c\/strong\u003e  6 AWG\u003cbr\u003e\u003cstrong\u003eInner Jacket Thickness:\u003c\/strong\u003e 110mil\u003cbr\u003e\u003cstrong\u003eDia. Over Armour: \u003c\/strong\u003e2.421inch\u003cbr\u003e\u003cstrong\u003eOverall Jacket Thickness:\u003c\/strong\u003e  75mil\u003cbr\u003e\u003cstrong\u003eApprox.OD: \u003c\/strong\u003e2.577\u003cstrong\u003e \u003c\/strong\u003einch\u003cbr\u003e\u003cstrong\u003eApprox.Weight(lb\/1000)\u003c\/strong\u003e: 2754\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"width: 325.114px; height: 35.5966px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e665373\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":67613803872625,"sku":"NNC665373","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitleddesign_1_d538a474-ff80-4bee-bd1d-2905d73cabf0.png?v=1790838400"},{"product_id":"1-0-awg-3c-hvteck-aluminum-220-mil-nlepr-ts-aia-15kv-133-il-red-pvc-jacket-csa","title":"1\/0 AWG 3C HVTECK Aluminum 220 mil NLEPR TS AIA 15kV 133% IL Red PVC Jacket CSA","description":"\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e1\/0 AWG 3C HVTECK Aluminum 220 mil NLEPR TS AIA 15kV 133% IL Red PVC Jacket CSA\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC26362_1.pdf?v=1790838959\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan data-sheets-root=\"1\"\u003eApplication:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan data-sheets-root=\"1\"\u003eThe 15kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications. Rated FT4, -40°C, Hazardous Locations (HL). These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lbs \/FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids and are flame retardant.3 Conductor, 220 Mils No Lead Ethylene Propylene Rubber (NL-EPR), 133% Insulation Level, Tape Shield, Polyvinyl Chloride (PVC) Inner Jacket, Aluminum Interlocked Armour (AIA), Polyvinyl Chloride (PVC) Jacket.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eAlso Known as:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1\/0 AWG 3C 15kV HVTECK Cable, 1\/0 AWG 3C \u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e15kV HVTECK Armoured Cable, 1\/0 AWG 3C 15kV CSA Armoured Cable, 1\/0 AWG 3C15kV Medium Voltage Cable, 1\/0 AWG 3C15kV MV Cable, 1\/0 AWG 3C 15kV 3\/C Aluminum Cable, 1\/0 AWG 3C 3 Conductor 15kV Cable,1\/0 AWG 3C 3\/C Aluminum HV Cable, 1\/0 AWG 3C 220 mil NLEPR Cable, 1\/0 AWG 3C NL-EPR Insulated Cable, 1\/0 AWG 3C EPR Insulated Medium Voltage Cable, 1\/0-3C Tape Shielded MV Cable, 1\/0-3C Copper Tape Shield Cable, 1\/0-3C AIA Armoured Cable, 1\/0-3C Aluminum Interlocked Armour Cable, 1\/0-3C PVC Inner Jacket Cable, 1\/0-3C PVC Jacketed Armoured Cable, 1\/0-3C 15kV Shielded Power Cable, 1\/0-3C CSA 15kV Power Cable, 1\/0-3C Hazardous Location 15kV Cable, 1\/0-3C FT4 15kV Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Class B compact stranded 8000 Series aluminum per ASTM B800 and ASTM B836\u003cbr\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi-conducting cross-linked copolymer; A conductor separator is used for cable size larger than or equal to 500 Kcmil\u003cbr\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e 220 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% insulation level\u003cbr\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Strippable semi-conducting cross-linked copolymer\u003cbr\u003e \u003cstrong\u003eCopper Tape Shield:\u003c\/strong\u003e Helically wrapped 5 mil copper tape with 25% overlap\u003cbr\u003e \u003cstrong\u003eFiller:\u003c\/strong\u003e Interstices filled with non-hydroscoping\/non-wicking fillers\u003cbr\u003e \u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e Class B compressed stranded bare copper ground per ASTM B3 and ASTM B8\u003cbr\u003e \u003cstrong\u003eBinder:\u003c\/strong\u003e Polypropylene tape\u003cbr\u003e \u003cstrong\u003eInner Jacket:\u003c\/strong\u003e PVC inner jacket\u003cbr\u003e \u003cstrong\u003eArmour:\u003c\/strong\u003e Aluminum Interlocked Armour (AIA)\u003cbr\u003e \u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e Red Polyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e ASTM B801 Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy\u003cbr\u003e ASTM B836 Compact Rounded Stranded Aluminum Conductors\u003cbr\u003e CSA C22.2 No. 174 Cables in Hazardous Locations\u003cbr\u003e CSA C22.2 No. 2556 \u0026amp; No. 0.3 Wire and Cable Test Methods\u003cbr\u003e CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV\u003cbr\u003e CSA C68.3 Shielded \u0026amp; Concentric Neutral Power Cable - 5 to 46 kV\u003cbr\u003e CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating\u003cbr\u003e CSA HL - for Hazardous Locations rating\u003cbr\u003e CSA SUN RES - for Sunlight Resistant rating\u003cbr\u003e ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable\u003cbr\u003e ICEA T-29-520 Flame Test (210,000 BTU\/Hr)\u003cbr\u003e IEEE 383 Flame Test (70,000 btu)\u003cbr\u003e IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003cbr\u003e FT1 Flame Test (1,706 BTU\/Hr nominal - Vertical Wire Flame Test)\u003cbr\u003e AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements).\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e 1\/0 AWG\u003cbr\u003e\u003cstrong\u003eNo of Strand:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003eDiameter Over Conductor: \u003c\/strong\u003e0.336inch\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation:\u003c\/strong\u003e  0.814inch\u003cbr\u003e\u003cstrong\u003eInsulation Thickness:\u003c\/strong\u003e 220mil\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation Shield:\u003c\/strong\u003e 0.874inch\u003cbr\u003e\u003cstrong\u003eGround Size:\u003c\/strong\u003e  6 AWG\u003cbr\u003e\u003cstrong\u003eInner Jacket Thickness:\u003c\/strong\u003e 110mil\u003cbr\u003e\u003cstrong\u003eDia. Over Armour: \u003c\/strong\u003e2.507inch\u003cbr\u003e\u003cstrong\u003eOverall Jacket Thickness:\u003c\/strong\u003e 75mil\u003cbr\u003e\u003cstrong\u003eApprox.OD: \u003c\/strong\u003e2.657 inch\u003cbr\u003e\u003cstrong\u003eApprox.Weight(lb\/1000)\u003c\/strong\u003e: 2726\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":67613898670449,"sku":"NNC45LD","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitleddesign_1_d538a474-ff80-4bee-bd1d-2905d73cabf0.png?v=1790838400"},{"product_id":"2-0-awg-3c-hvteck-aluminum-220-mil-nlepr-ts-aia-15kv-133-il-red-pvc-jacket-csa","title":"2\/0 AWG 3C HVTECK Aluminum 220 mil NLEPR TS AIA 15kV 133% IL Red PVC Jacket CSA","description":"\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e2\/0 AWG 3C HVTECK Aluminum 220 mil NLEPR TS AIA 15kV 133% IL Red PVC Jacket CSA\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC26362_1.pdf?v=1790838959\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan data-sheets-root=\"1\"\u003eApplication:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan data-sheets-root=\"1\"\u003eThe 15kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications. Rated FT4, -40°C, Hazardous Locations (HL). These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lbs \/FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids and are flame retardant.3 Conductor, 220 Mils No Lead Ethylene Propylene Rubber (NL-EPR), 133% Insulation Level, Tape Shield, Polyvinyl Chloride (PVC) Inner Jacket, Aluminum Interlocked Armour (AIA), Polyvinyl Chloride (PVC) Jacket.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eAlso Known as:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e2\/0 AWG 3C 15kV HVTECK Cable, 2\/0 AWG 3C \u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e15kV HVTECK Armoured Cable, 2\/0 AWG 3C 15kV CSA Armoured Cable, 2\/0 AWG 3C15kV Medium Voltage Cable, 2\/0 AWG 3C15kV MV Cable, 2\/0 AWG 3C 15kV 3\/C Aluminum Cable, 2\/0 AWG 3C 3 Conductor 15kV Cable,2\/0 AWG 3C 3\/C Aluminum HV Cable, 2\/0 AWG 3C 220 mil NLEPR Cable, 2\/0 AWG 3C NL-EPR Insulated Cable, 2\/0 AWG 3C EPR Insulated Medium Voltage Cable, 2\/0-3C Tape Shielded MV Cable, 2\/0-3C Copper Tape Shield Cable, 2\/0-3C AIA Armoured Cable, 2\/0-3C Aluminum Interlocked Armour Cable, 2\/0-3C PVC Inner Jacket Cable, 2\/0-3C PVC Jacketed Armoured Cable, 2\/0-3C 15kV Shielded Power Cable, 2\/0-3C CSA 15kV Power Cable, 2\/0-3C Hazardous Location 15kV Cable, 2\/0-3C FT4 15kV Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Class B compact stranded 8000 Series aluminum per ASTM B800 and ASTM B836\u003cbr\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi-conducting cross-linked copolymer; A conductor separator is used for cable size larger than or equal to 500 Kcmil\u003cbr\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e 220 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% insulation level\u003cbr\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Strippable semi-conducting cross-linked copolymer\u003cbr\u003e \u003cstrong\u003eCopper Tape Shield:\u003c\/strong\u003e Helically wrapped 5 mil copper tape with 25% overlap\u003cbr\u003e \u003cstrong\u003eFiller:\u003c\/strong\u003e Interstices filled with non-hydroscoping\/non-wicking fillers\u003cbr\u003e \u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e Class B compressed stranded bare copper ground per ASTM B3 and ASTM B8\u003cbr\u003e \u003cstrong\u003eBinder:\u003c\/strong\u003e Polypropylene tape\u003cbr\u003e \u003cstrong\u003eInner Jacket:\u003c\/strong\u003e PVC inner jacket\u003cbr\u003e \u003cstrong\u003eArmour:\u003c\/strong\u003e Aluminum Interlocked Armour (AIA)\u003cbr\u003e \u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e Red Polyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e ASTM B801 Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy\u003cbr\u003e ASTM B836 Compact Rounded Stranded Aluminum Conductors\u003cbr\u003e CSA C22.2 No. 174 Cables in Hazardous Locations\u003cbr\u003e CSA C22.2 No. 2556 \u0026amp; No. 0.3 Wire and Cable Test Methods\u003cbr\u003e CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV\u003cbr\u003e CSA C68.3 Shielded \u0026amp; Concentric Neutral Power Cable - 5 to 46 kV\u003cbr\u003e CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating\u003cbr\u003e CSA HL - for Hazardous Locations rating\u003cbr\u003e CSA SUN RES - for Sunlight Resistant rating\u003cbr\u003e ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable\u003cbr\u003e ICEA T-29-520 Flame Test (210,000 BTU\/Hr)\u003cbr\u003e IEEE 383 Flame Test (70,000 btu)\u003cbr\u003e IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003cbr\u003e FT1 Flame Test (1,706 BTU\/Hr nominal - Vertical Wire Flame Test)\u003cbr\u003e AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements).\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e 2\/0 AWG\u003cbr\u003e\u003cstrong\u003eNo of Strand:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003eDiameter Over Conductor: \u003c\/strong\u003e0.376inch\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation:\u003c\/strong\u003e 0.854inch\u003cbr\u003e\u003cstrong\u003eInsulation Thickness:\u003c\/strong\u003e 220mil\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation Shield:\u003c\/strong\u003e  0.914inch\u003cbr\u003e\u003cstrong\u003eGround Size:\u003c\/strong\u003e  6 AWG\u003cbr\u003e\u003cstrong\u003eInner Jacket Thickness:\u003c\/strong\u003e 110mil\u003cbr\u003e\u003cstrong\u003eDia. Over Armour:\u003c\/strong\u003e 2.593inch\u003cbr\u003e\u003cstrong\u003eOverall Jacket Thickness:\u003c\/strong\u003e 75mil\u003cbr\u003e\u003cstrong\u003eApprox.OD: \u003c\/strong\u003e2.743inch\u003cbr\u003e\u003cstrong\u003eApprox.Weight(lb\/1000)\u003c\/strong\u003e: 2929\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":67613986488689,"sku":"NNC52WD","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitleddesign_1_d538a474-ff80-4bee-bd1d-2905d73cabf0.png?v=1790838400"},{"product_id":"3-0-awg-3c-hvteck-aluminum-220-mil-nlepr-ts-aia-15kv-133-il-red-pvc-jacket-csa","title":"3\/0 AWG 3C HVTECK Aluminum 220 mil NLEPR TS AIA 15kV 133% IL Red PVC Jacket CSA","description":"\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e3\/0 AWG 3C HVTECK Aluminum 220 mil NLEPR TS AIA 15kV 133% IL Red PVC Jacket CSA\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC26362_1.pdf?v=1790838959\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan data-sheets-root=\"1\"\u003eApplication:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan data-sheets-root=\"1\"\u003eThe 15kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications. Rated FT4, -40°C, Hazardous Locations (HL). These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lbs \/FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids and are flame retardant.3 Conductor, 220 Mils No Lead Ethylene Propylene Rubber (NL-EPR), 133% Insulation Level, Tape Shield, Polyvinyl Chloride (PVC) Inner Jacket, Aluminum Interlocked Armour (AIA), Polyvinyl Chloride (PVC) Jacket.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eAlso Known as:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e3\/0 AWG 3C 15kV HVTECK Cable, 3\/0 AWG 3C \u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e15kV HVTECK Armoured Cable, 3\/0 AWG 3C 15kV CSA Armoured Cable, 3\/0 AWG 3C15kV Medium Voltage Cable, 3\/0 AWG 3C15kV MV Cable, 3\/0 AWG 3C 15kV 3\/C Aluminum Cable, 3\/0 AWG 3C 3 Conductor 15kV Cable, 3\/0 AWG 3C 3\/C Aluminum HV Cable, 3\/0 AWG 3C 220 mil NLEPR Cable, 3\/0 AWG 3C NL-EPR Insulated Cable, 3\/0 AWG 3C EPR Insulated Medium Voltage Cable, 3\/0-3C Tape Shielded MV Cable, 3\/0-3C Copper Tape Shield Cable, 3\/0-3C AIA Armoured Cable, 3\/0-3C Aluminum Interlocked Armour Cable, 3\/0-3C PVC Inner Jacket Cable, 3\/0-3C PVC Jacketed Armoured Cable, 3\/0-3C 15kV Shielded Power Cable, 3\/0-3C CSA 15kV Power Cable, 3\/0-3C Hazardous Location 15kV Cable, 3\/0-3C FT4 15kV Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Class B compact stranded 8000 Series aluminum per ASTM B800 and ASTM B836\u003cbr\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi-conducting cross-linked copolymer; A conductor separator is used for cable size larger than or equal to 500 Kcmil\u003cbr\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e 220 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% insulation level\u003cbr\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Strippable semi-conducting cross-linked copolymer\u003cbr\u003e \u003cstrong\u003eCopper Tape Shield:\u003c\/strong\u003e Helically wrapped 5 mil copper tape with 25% overlap\u003cbr\u003e \u003cstrong\u003eFiller:\u003c\/strong\u003e Interstices filled with non-hydroscoping\/non-wicking fillers\u003cbr\u003e \u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e Class B compressed stranded bare copper ground per ASTM B3 and ASTM B8\u003cbr\u003e \u003cstrong\u003eBinder:\u003c\/strong\u003e Polypropylene tape\u003cbr\u003e \u003cstrong\u003eInner Jacket:\u003c\/strong\u003e PVC inner jacket\u003cbr\u003e \u003cstrong\u003eArmour:\u003c\/strong\u003e Aluminum Interlocked Armour (AIA)\u003cbr\u003e \u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e Red Polyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e ASTM B801 Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy\u003cbr\u003e ASTM B836 Compact Rounded Stranded Aluminum Conductors\u003cbr\u003e CSA C22.2 No. 174 Cables in Hazardous Locations\u003cbr\u003e CSA C22.2 No. 2556 \u0026amp; No. 0.3 Wire and Cable Test Methods\u003cbr\u003e CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV\u003cbr\u003e CSA C68.3 Shielded \u0026amp; Concentric Neutral Power Cable - 5 to 46 kV\u003cbr\u003e CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating\u003cbr\u003e CSA HL - for Hazardous Locations rating\u003cbr\u003e CSA SUN RES - for Sunlight Resistant rating\u003cbr\u003e ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable\u003cbr\u003e ICEA T-29-520 Flame Test (210,000 BTU\/Hr)\u003cbr\u003e IEEE 383 Flame Test (70,000 btu)\u003cbr\u003e IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003cbr\u003e FT1 Flame Test (1,706 BTU\/Hr nominal - Vertical Wire Flame Test)\u003cbr\u003e AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements).\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e 3\/0 AWG\u003cbr\u003e\u003cstrong\u003eNo of Strand:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003eDiameter Over Conductor: \u003c\/strong\u003e0.422inch\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation:\u003c\/strong\u003e 0.900inch\u003cbr\u003e\u003cstrong\u003eInsulation Thickness:\u003c\/strong\u003e 220mil\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation Shield:\u003c\/strong\u003e 0.960inch\u003cbr\u003e\u003cstrong\u003eGround Size:\u003c\/strong\u003e  6 AWG\u003cbr\u003e\u003cstrong\u003eInner Jacket Thickness:\u003c\/strong\u003e 110mil\u003cbr\u003e\u003cstrong\u003eDia. Over Armour:\u003c\/strong\u003e 2.693inch\u003cbr\u003e\u003cstrong\u003eOverall Jacket Thickness:\u003c\/strong\u003e 75mil\u003cbr\u003e\u003cstrong\u003eApprox.OD:  \u003c\/strong\u003e2.843inch\u003cbr\u003e\u003cstrong\u003eApprox.Weight(lb\/1000)\u003c\/strong\u003e: 3176\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":67614005756273,"sku":"NNC4552","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitleddesign_1_d538a474-ff80-4bee-bd1d-2905d73cabf0.png?v=1790838400"},{"product_id":"4-0-awg-3c-hvteck-aluminum-220-mil-nlepr-ts-aia-15kv-133-il-red-pvc-jacket-csa","title":"4\/0 AWG 3C HVTECK Aluminum 220 mil NLEPR TS AIA 15kV 133% IL Red PVC Jacket CSA","description":"\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e4\/0 AWG 3C HVTECK Aluminum 220 mil NLEPR TS AIA 15kV 133% IL Red PVC Jacket CSA\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC26362_1.pdf?v=1790838959\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan data-sheets-root=\"1\"\u003eApplication:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan data-sheets-root=\"1\"\u003eThe 15kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications. Rated FT4, -40°C, Hazardous Locations (HL). These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lbs \/FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids and are flame retardant.3 Conductor, 220 Mils No Lead Ethylene Propylene Rubber (NL-EPR), 133% Insulation Level, Tape Shield, Polyvinyl Chloride (PVC) Inner Jacket, Aluminum Interlocked Armour (AIA), Polyvinyl Chloride (PVC) Jacket.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eAlso Known as:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e4\/0 AWG 3C 15kV HVTECK Cable, 4\/0 AWG 3C \u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e15kV HVTECK Armoured Cable, 4\/0 AWG 3C 15kV CSA Armoured Cable, 4\/0 AWG 3C15kV Medium Voltage Cable, 4\/0 AWG 3C15kV MV Cable, 4\/0 AWG 3C 15kV 3\/C Aluminum Cable, 4\/0 AWG 3C 3 Conductor 15kV Cable, 4\/0 AWG 3C 3\/C Aluminum HV Cable, 4\/0 AWG 3C 220 mil NLEPR Cable, 4\/0 AWG 3C NL-EPR Insulated Cable, 4\/0 AWG 3C EPR Insulated Medium Voltage Cable, 4\/0-3C Tape Shielded MV Cable, 4\/0-3C Copper Tape Shield Cable, 4\/0-3C AIA Armoured Cable, 4\/0-3C Aluminum Interlocked Armour Cable, 4\/0-3C PVC Inner Jacket Cable, 4\/0-3C PVC Jacketed Armoured Cable, 4\/0-3C 15kV Shielded Power Cable, 4\/0-3C CSA 15kV Power Cable, 4\/0-3C Hazardous Location 15kV Cable, 4\/0-3C FT4 15kV Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Class B compact stranded 8000 Series aluminum per ASTM B800 and ASTM B836\u003cbr\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi-conducting cross-linked copolymer; A conductor separator is used for cable size larger than or equal to 500 Kcmil\u003cbr\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e 220 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% insulation level\u003cbr\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Strippable semi-conducting cross-linked copolymer\u003cbr\u003e \u003cstrong\u003eCopper Tape Shield:\u003c\/strong\u003e Helically wrapped 5 mil copper tape with 25% overlap\u003cbr\u003e \u003cstrong\u003eFiller:\u003c\/strong\u003e Interstices filled with non-hydroscoping\/non-wicking fillers\u003cbr\u003e \u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e Class B compressed stranded bare copper ground per ASTM B3 and ASTM B8\u003cbr\u003e \u003cstrong\u003eBinder:\u003c\/strong\u003e Polypropylene tape\u003cbr\u003e \u003cstrong\u003eInner Jacket:\u003c\/strong\u003e PVC inner jacket\u003cbr\u003e \u003cstrong\u003eArmour:\u003c\/strong\u003e Aluminum Interlocked Armour (AIA)\u003cbr\u003e \u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e Red Polyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e ASTM B801 Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy\u003cbr\u003e ASTM B836 Compact Rounded Stranded Aluminum Conductors\u003cbr\u003e CSA C22.2 No. 174 Cables in Hazardous Locations\u003cbr\u003e CSA C22.2 No. 2556 \u0026amp; No. 0.3 Wire and Cable Test Methods\u003cbr\u003e CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV\u003cbr\u003e CSA C68.3 Shielded \u0026amp; Concentric Neutral Power Cable - 5 to 46 kV\u003cbr\u003e CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating\u003cbr\u003e CSA HL - for Hazardous Locations rating\u003cbr\u003e CSA SUN RES - for Sunlight Resistant rating\u003cbr\u003e ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable\u003cbr\u003e ICEA T-29-520 Flame Test (210,000 BTU\/Hr)\u003cbr\u003e IEEE 383 Flame Test (70,000 btu)\u003cbr\u003e IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003cbr\u003e FT1 Flame Test (1,706 BTU\/Hr nominal - Vertical Wire Flame Test)\u003cbr\u003e AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements).\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e4\/0 AWG\u003cbr\u003e\u003cstrong\u003eNo of Strand:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003eDiameter Over Conductor:  \u003c\/strong\u003e0.4742inch\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation:\u003c\/strong\u003e 0.952inch\u003cbr\u003e\u003cstrong\u003eInsulation Thickness:\u003c\/strong\u003e 220mil\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation Shield:\u003c\/strong\u003e 1.012inch\u003cbr\u003e\u003cstrong\u003eGround Size:\u003c\/strong\u003e  6 AWG\u003cbr\u003e\u003cstrong\u003eInner Jacket Thickness:\u003c\/strong\u003e 110mil\u003cbr\u003e\u003cstrong\u003eDia. Over Armour:\u003c\/strong\u003e 2.805inch\u003cbr\u003e\u003cstrong\u003eOverall Jacket Thickness:\u003c\/strong\u003e 75mil\u003cbr\u003e\u003cstrong\u003eApprox.OD: \u003c\/strong\u003e2.955inch\u003cbr\u003e\u003cstrong\u003eApprox.Weight(lb\/1000)\u003c\/strong\u003e: 3463\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":67614033150321,"sku":"NNC1274","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitleddesign_1_d538a474-ff80-4bee-bd1d-2905d73cabf0.png?v=1790838400"},{"product_id":"250-mcm-3c-hvteck-aluminum-220-mil-nlepr-ts-aia-15kv-133-il-red-pvc-jacket-csa","title":"250 MCM 3C HVTECK Aluminum 220 mil NLEPR TS AIA 15kV 133% IL Red PVC Jacket CSA","description":"\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e250 MCM 3C HVTECK Aluminum 220 mil NLEPR TS AIA 15kV 133% IL Red PVC Jacket CSA\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC26362_1.pdf?v=1790838959\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan data-sheets-root=\"1\"\u003eApplication:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan data-sheets-root=\"1\"\u003eThe 15kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications. Rated FT4, -40°C, Hazardous Locations (HL). These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lbs \/FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids and are flame retardant.3 Conductor, 220 Mils No Lead Ethylene Propylene Rubber (NL-EPR), 133% Insulation Level, Tape Shield, Polyvinyl Chloride (PVC) Inner Jacket, Aluminum Interlocked Armour (AIA), Polyvinyl Chloride (PVC) Jacket.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eAlso Known as:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e250 AWG 3C 15kV HVTECK Cable, 250 AWG 3C \u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e15kV HVTECK Armoured Cable, 250 AWG 3C 15kV CSA Armoured Cable, 250 AWG 3C15kV Medium Voltage Cable, 250 AWG 3C15kV MV Cable, 250 AWG 3C 15kV 3\/C Aluminum Cable, 250 AWG 3C 3 Conductor 15kV Cable, 250 AWG 3C 3\/C Aluminum HV Cable, 250 AWG 3C 220 mil NLEPR Cable, 250 AWG 3C NL-EPR Insulated Cable, 250 AWG 3C EPR Insulated Medium Voltage Cable, 250-3C Tape Shielded MV Cable, 250-3C Copper Tape Shield Cable, 250-3C AIA Armoured Cable, 250-3C Aluminum Interlocked Armour Cable, 250-3C PVC Inner Jacket Cable,250-3C PVC Jacketed Armoured Cable, 250-3C 15kV Shielded Power Cable, 250-3C CSA 15kV Power Cable,250-3C Hazardous Location 15kV Cable, 250-3C FT4 15kV Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Class B compact stranded 8000 Series aluminum per ASTM B800 and ASTM B836\u003cbr\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi-conducting cross-linked copolymer; A conductor separator is used for cable size larger than or equal to 500 Kcmil\u003cbr\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e 220 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% insulation level\u003cbr\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Strippable semi-conducting cross-linked copolymer\u003cbr\u003e \u003cstrong\u003eCopper Tape Shield:\u003c\/strong\u003e Helically wrapped 5 mil copper tape with 25% overlap\u003cbr\u003e \u003cstrong\u003eFiller:\u003c\/strong\u003e Interstices filled with non-hydroscoping\/non-wicking fillers\u003cbr\u003e \u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e Class B compressed stranded bare copper ground per ASTM B3 and ASTM B8\u003cbr\u003e \u003cstrong\u003eBinder:\u003c\/strong\u003e Polypropylene tape\u003cbr\u003e \u003cstrong\u003eInner Jacket:\u003c\/strong\u003e PVC inner jacket\u003cbr\u003e \u003cstrong\u003eArmour:\u003c\/strong\u003e Aluminum Interlocked Armour (AIA)\u003cbr\u003e \u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e Red Polyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e ASTM B801 Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy\u003cbr\u003e ASTM B836 Compact Rounded Stranded Aluminum Conductors\u003cbr\u003e CSA C22.2 No. 174 Cables in Hazardous Locations\u003cbr\u003e CSA C22.2 No. 2556 \u0026amp; No. 0.3 Wire and Cable Test Methods\u003cbr\u003e CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV\u003cbr\u003e CSA C68.3 Shielded \u0026amp; Concentric Neutral Power Cable - 5 to 46 kV\u003cbr\u003e CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating\u003cbr\u003e CSA HL - for Hazardous Locations rating\u003cbr\u003e CSA SUN RES - for Sunlight Resistant rating\u003cbr\u003e ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable\u003cbr\u003e ICEA T-29-520 Flame Test (210,000 BTU\/Hr)\u003cbr\u003e IEEE 383 Flame Test (70,000 btu)\u003cbr\u003e IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003cbr\u003e FT1 Flame Test (1,706 BTU\/Hr nominal - Vertical Wire Flame Test)\u003cbr\u003e AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements).\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e250 AWG\u003cbr\u003e\u003cstrong\u003eNo of Strand:\u003c\/strong\u003e 37\u003cbr\u003e\u003cstrong\u003eDiameter Over Conductor: \u003c\/strong\u003e0.520inch\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation:\u003c\/strong\u003e 1.006inch\u003cbr\u003e\u003cstrong\u003eInsulation Thickness:\u003c\/strong\u003e 220mil\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation Shield:\u003c\/strong\u003e  1.066inch\u003cbr\u003e\u003cstrong\u003eGround Size:\u003c\/strong\u003e  4 AWG\u003cbr\u003e\u003cstrong\u003eInner Jacket Thickness:\u003c\/strong\u003e 110mil\u003cbr\u003e\u003cstrong\u003eDia. Over Armour:\u003c\/strong\u003e 2.922inch\u003cbr\u003e\u003cstrong\u003eOverall Jacket Thickness:\u003c\/strong\u003e 75mil\u003cbr\u003e\u003cstrong\u003eApprox.OD: \u003c\/strong\u003e3.072inch\u003cbr\u003e\u003cstrong\u003eApprox.Weight(lb\/1000)\u003c\/strong\u003e: 3772\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":67614099833201,"sku":"NNC7831","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitleddesign_1_d538a474-ff80-4bee-bd1d-2905d73cabf0.png?v=1790838400"},{"product_id":"350-mcm-3c-hvteck-aluminum-220-mil-nlepr-ts-aia-15kv-133-il-red-pvc-jacket-csa","title":"350 MCM 3C HVTECK Aluminum 220 mil NLEPR TS AIA 15kV 133% IL Red PVC Jacket CSA","description":"\u003ch2\u003e350 MCM 3C HVTECK Aluminum 220 mil NLEPR TS AIA 15kV 133% IL Red PVC Jacket CSA\u003c\/h2\u003e\n\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC26362_1.pdf?v=1790838959\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan data-sheets-root=\"1\"\u003eApplication:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan data-sheets-root=\"1\"\u003eThe 15kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications. Rated FT4, -40°C, Hazardous Locations (HL). These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lbs \/FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids and are flame retardant.3 Conductor, 220 Mils No Lead Ethylene Propylene Rubber (NL-EPR), 133% Insulation Level, Tape Shield, Polyvinyl Chloride (PVC) Inner Jacket, Aluminum Interlocked Armour (AIA), Polyvinyl Chloride (PVC) Jacket.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eAlso Known as:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e350 AWG 3C 15kV HVTECK Cable, 350 AWG 3C \u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e15kV HVTECK Armoured Cable, 350 AWG 3C 15kV CSA Armoured Cable, 350 AWG 3C15kV Medium Voltage Cable, 350 AWG 3C15kV MV Cable, 350 AWG 3C 15kV 3\/C Aluminum Cable, 350 AWG 3C 3 Conductor 15kV Cable, 350 AWG 3C 3\/C Aluminum HV Cable, 350 AWG 3C 220 mil NLEPR Cable, 350 AWG 3C NL-EPR Insulated Cable, 350 AWG 3C EPR Insulated Medium Voltage Cable, 350-3C Tape Shielded MV Cable, 350-3C Copper Tape Shield Cable, 350-3C AIA Armoured Cable, 350-3C Aluminum Interlocked Armour Cable, 350-3C PVC Inner Jacket Cable, 350-3C PVC Jacketed Armoured Cable, 350-3C 15kV Shielded Power Cable, 350-3C CSA 15kV Power Cable,350-3C Hazardous Location 15kV Cable, 350-3C FT4 15kV Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Class B compact stranded 8000 Series aluminum per ASTM B800 and ASTM B836\u003cbr\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi-conducting cross-linked copolymer; A conductor separator is used for cable size larger than or equal to 500 Kcmil\u003cbr\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e 220 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% insulation level\u003cbr\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Strippable semi-conducting cross-linked copolymer\u003cbr\u003e \u003cstrong\u003eCopper Tape Shield:\u003c\/strong\u003e Helically wrapped 5 mil copper tape with 25% overlap\u003cbr\u003e \u003cstrong\u003eFiller:\u003c\/strong\u003e Interstices filled with non-hydroscoping\/non-wicking fillers\u003cbr\u003e \u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e Class B compressed stranded bare copper ground per ASTM B3 and ASTM B8\u003cbr\u003e \u003cstrong\u003eBinder:\u003c\/strong\u003e Polypropylene tape\u003cbr\u003e \u003cstrong\u003eInner Jacket:\u003c\/strong\u003e PVC inner jacket\u003cbr\u003e \u003cstrong\u003eArmour:\u003c\/strong\u003e Aluminum Interlocked Armour (AIA)\u003cbr\u003e \u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e Red Polyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e ASTM B801 Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy\u003cbr\u003e ASTM B836 Compact Rounded Stranded Aluminum Conductors\u003cbr\u003e CSA C22.2 No. 174 Cables in Hazardous Locations\u003cbr\u003e CSA C22.2 No. 2556 \u0026amp; No. 0.3 Wire and Cable Test Methods\u003cbr\u003e CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV\u003cbr\u003e CSA C68.3 Shielded \u0026amp; Concentric Neutral Power Cable - 5 to 46 kV\u003cbr\u003e CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating\u003cbr\u003e CSA HL - for Hazardous Locations rating\u003cbr\u003e CSA SUN RES - for Sunlight Resistant rating\u003cbr\u003e ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable\u003cbr\u003e ICEA T-29-520 Flame Test (210,000 BTU\/Hr)\u003cbr\u003e IEEE 383 Flame Test (70,000 btu)\u003cbr\u003e IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003cbr\u003e FT1 Flame Test (1,706 BTU\/Hr nominal - Vertical Wire Flame Test)\u003cbr\u003e AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements).\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e350 AWG\u003cbr\u003e\u003cstrong\u003eNo of Strand:\u003c\/strong\u003e 37\u003cbr\u003e\u003cstrong\u003eDiameter Over Conductor: \u003c\/strong\u003e0.615inch\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation:\u003c\/strong\u003e 1.101inch\u003cbr\u003e\u003cstrong\u003eInsulation Thickness:\u003c\/strong\u003e 220mil\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation Shield:\u003c\/strong\u003e 1.161inch\u003cbr\u003e\u003cstrong\u003eGround Size:\u003c\/strong\u003e  4 AWG\u003cbr\u003e\u003cstrong\u003eInner Jacket Thickness:\u003c\/strong\u003e 125mil\u003cbr\u003e\u003cstrong\u003eDia. Over Armour:\u003c\/strong\u003e 3.157inch\u003cbr\u003e\u003cstrong\u003eOverall Jacket Thickness:\u003c\/strong\u003e 85mil\u003cbr\u003e\u003cstrong\u003eApprox.OD: \u003c\/strong\u003e3.327inch\u003cbr\u003e\u003cstrong\u003eApprox.Weight(lb\/1000)\u003c\/strong\u003e: 4522\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":67614170612081,"sku":"NN1357","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitleddesign_1_d538a474-ff80-4bee-bd1d-2905d73cabf0.png?v=1790838400"},{"product_id":"500-mcm-3c-hvteck-aluminum-220-mil-nlepr-ts-aia-15kv-133-il-red-pvc-jacket-csa-1","title":"500 MCM 3C HVTECK Aluminum 220 mil NLEPR TS AIA 15kV 133% IL Red PVC Jacket CSA","description":"\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e500 MCM 3C HVTECK Aluminum 220 mil NLEPR TS AIA 15kV 133% IL Red PVC Jacket CSA\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC26362_1.pdf?v=1790838959\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan data-sheets-root=\"1\"\u003eApplication:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan data-sheets-root=\"1\"\u003eThe 15kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications. Rated FT4, -40°C, Hazardous Locations (HL). These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lbs \/FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids and are flame retardant.3 Conductor, 220 Mils No Lead Ethylene Propylene Rubber (NL-EPR), 133% Insulation Level, Tape Shield, Polyvinyl Chloride (PVC) Inner Jacket, Aluminum Interlocked Armour (AIA), Polyvinyl Chloride (PVC) Jacket.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eAlso Known as:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e500 AWG 3C 15kV HVTECK Cable, 500 AWG 3C \u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e15kV HVTECK Armoured Cable, 500 AWG 3C 15kV CSA Armoured Cable, 500 AWG 3C15kV Medium Voltage Cable, 500 AWG 3C15kV MV Cable, 500 AWG 3C 15kV 3\/C Aluminum Cable, 500 AWG 3C 3 Conductor 15kV Cable, 500 AWG 3C 3\/C Aluminum HV Cable, 500 AWG 3C 220 mil NLEPR Cable, 500 AWG 3C NL-EPR Insulated Cable, 500 AWG 3C EPR Insulated Medium Voltage Cable, 500-3C Tape Shielded MV Cable, 500-3C Copper Tape Shield Cable, 500-3C AIA Armoured Cable, 500-3C Aluminum Interlocked Armour Cable, 500-3C PVC Inner Jacket Cable, 500-3C PVC Jacketed Armoured Cable, 500-3C 15kV Shielded Power Cable, 500-3C CSA 15kV Power Cable, 500-3C Hazardous Location 15kV Cable, 500-3C FT4 15kV Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Class B compact stranded 8000 Series aluminum per ASTM B800 and ASTM B836\u003cbr\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi-conducting cross-linked copolymer; A conductor separator is used for cable size larger than or equal to 500 Kcmil\u003cbr\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e 220 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% insulation level\u003cbr\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Strippable semi-conducting cross-linked copolymer\u003cbr\u003e \u003cstrong\u003eCopper Tape Shield:\u003c\/strong\u003e Helically wrapped 5 mil copper tape with 25% overlap\u003cbr\u003e \u003cstrong\u003eFiller:\u003c\/strong\u003e Interstices filled with non-hydroscoping\/non-wicking fillers\u003cbr\u003e \u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e Class B compressed stranded bare copper ground per ASTM B3 and ASTM B8\u003cbr\u003e \u003cstrong\u003eBinder:\u003c\/strong\u003e Polypropylene tape\u003cbr\u003e \u003cstrong\u003eInner Jacket:\u003c\/strong\u003e PVC inner jacket\u003cbr\u003e \u003cstrong\u003eArmour:\u003c\/strong\u003e Aluminum Interlocked Armour (AIA)\u003cbr\u003e \u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e Red Polyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e ASTM B801 Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy\u003cbr\u003e ASTM B836 Compact Rounded Stranded Aluminum Conductors\u003cbr\u003e CSA C22.2 No. 174 Cables in Hazardous Locations\u003cbr\u003e CSA C22.2 No. 2556 \u0026amp; No. 0.3 Wire and Cable Test Methods\u003cbr\u003e CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV\u003cbr\u003e CSA C68.3 Shielded \u0026amp; Concentric Neutral Power Cable - 5 to 46 kV\u003cbr\u003e CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating\u003cbr\u003e CSA HL - for Hazardous Locations rating\u003cbr\u003e CSA SUN RES - for Sunlight Resistant rating\u003cbr\u003e ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable\u003cbr\u003e ICEA T-29-520 Flame Test (210,000 BTU\/Hr)\u003cbr\u003e IEEE 383 Flame Test (70,000 btu)\u003cbr\u003e IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003cbr\u003e FT1 Flame Test (1,706 BTU\/Hr nominal - Vertical Wire Flame Test)\u003cbr\u003e AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements).\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e500 AWG\u003cbr\u003e\u003cstrong\u003eNo of Strand:\u003c\/strong\u003e 37\u003cbr\u003e\u003cstrong\u003eDiameter Over Conductor: \u003c\/strong\u003e0.735inch\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation:\u003c\/strong\u003e 1.221inch\u003cbr\u003e\u003cstrong\u003eInsulation Thickness:\u003c\/strong\u003e 220mil\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation Shield:\u003c\/strong\u003e 1.281inch\u003cbr\u003e\u003cstrong\u003eGround Size:\u003c\/strong\u003e  3 AWG\u003cbr\u003e\u003cstrong\u003eInner Jacket Thickness:\u003c\/strong\u003e 125mil\u003cbr\u003e\u003cstrong\u003eDia. Over Armour:\u003c\/strong\u003e 3.416inch\u003cbr\u003e\u003cstrong\u003eOverall Jacket Thickness:\u003c\/strong\u003e 85mil\u003cbr\u003e\u003cstrong\u003eApprox.OD: \u003c\/strong\u003e3.586inch\u003cbr\u003e\u003cstrong\u003eApprox.Weight(lb\/1000)\u003c\/strong\u003e: 5371\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":67614202560881,"sku":"NNC6571","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitleddesign_1_d538a474-ff80-4bee-bd1d-2905d73cabf0.png?v=1790838400"},{"product_id":"750-mcm-3c-hvteck-aluminum-220-mil-nlepr-ts-aia-15kv-133-il-red-pvc-jacket-csa","title":"750 MCM 3C HVTECK Aluminum 220 mil NLEPR TS AIA 15kV 133% IL Red PVC Jacket CSA","description":"\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e750 MCM 3C HVTECK Aluminum 220 mil NLEPR TS AIA 15kV 133% IL Red PVC Jacket CSA\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC26362_1.pdf?v=1790838959\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan data-sheets-root=\"1\"\u003eApplication:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan data-sheets-root=\"1\"\u003eThe 15kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications. Rated FT4, -40°C, Hazardous Locations (HL). These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lbs \/FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids and are flame retardant.3 Conductor, 220 Mils No Lead Ethylene Propylene Rubber (NL-EPR), 133% Insulation Level, Tape Shield, Polyvinyl Chloride (PVC) Inner Jacket, Aluminum Interlocked Armour (AIA), Polyvinyl Chloride (PVC) Jacket.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003eAlso Known as:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e750 AWG 3C 15kV HVTECK Cable, 750 AWG 3C \u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e15kV HVTECK Armoured Cable, 750 AWG 3C 15kV CSA Armoured Cable, 750 AWG 3C15kV Medium Voltage Cable, 750 AWG 3C15kV MV Cable,750 AWG 3C 15kV 3\/C Aluminum Cable, 750 AWG 3C 3 Conductor 15kV Cable, 750 AWG 3C 3\/C Aluminum HV Cable, 750 AWG 3C 220 mil NLEPR Cable, 750 AWG 3C NL-EPR Insulated Cable, 750 AWG 3C EPR Insulated Medium Voltage Cable,750-3C Tape Shielded MV Cable, 750-3C Copper Tape Shield Cable,750-3C AIA Armoured Cable, 750-3C Aluminum Interlocked Armour Cable, 750-3C PVC Inner Jacket Cable, 750-3C PVC Jacketed Armoured Cable, 750-3C 15kV Shielded Power Cable, 750-3C CSA 15kV Power Cable, 750-3C Hazardous Location 15kV Cable, 750-3C FT4 15kV Cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Class B compact stranded 8000 Series aluminum per ASTM B800 and ASTM B836\u003cbr\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Semi-conducting cross-linked copolymer; A conductor separator is used for cable size larger than or equal to 500 Kcmil\u003cbr\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e 220 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% insulation level\u003cbr\u003e \u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Strippable semi-conducting cross-linked copolymer\u003cbr\u003e \u003cstrong\u003eCopper Tape Shield:\u003c\/strong\u003e Helically wrapped 5 mil copper tape with 25% overlap\u003cbr\u003e \u003cstrong\u003eFiller:\u003c\/strong\u003e Interstices filled with non-hydroscoping\/non-wicking fillers\u003cbr\u003e \u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e Class B compressed stranded bare copper ground per ASTM B3 and ASTM B8\u003cbr\u003e \u003cstrong\u003eBinder:\u003c\/strong\u003e Polypropylene tape\u003cbr\u003e \u003cstrong\u003eInner Jacket:\u003c\/strong\u003e PVC inner jacket\u003cbr\u003e \u003cstrong\u003eArmour:\u003c\/strong\u003e Aluminum Interlocked Armour (AIA)\u003cbr\u003e \u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e Red Polyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e ASTM B801 Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy\u003cbr\u003e ASTM B836 Compact Rounded Stranded Aluminum Conductors\u003cbr\u003e CSA C22.2 No. 174 Cables in Hazardous Locations\u003cbr\u003e CSA C22.2 No. 2556 \u0026amp; No. 0.3 Wire and Cable Test Methods\u003cbr\u003e CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV\u003cbr\u003e CSA C68.3 Shielded \u0026amp; Concentric Neutral Power Cable - 5 to 46 kV\u003cbr\u003e CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating\u003cbr\u003e CSA HL - for Hazardous Locations rating\u003cbr\u003e CSA SUN RES - for Sunlight Resistant rating\u003cbr\u003e ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable\u003cbr\u003e ICEA T-29-520 Flame Test (210,000 BTU\/Hr)\u003cbr\u003e IEEE 383 Flame Test (70,000 btu)\u003cbr\u003e IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003cbr\u003e FT1 Flame Test (1,706 BTU\/Hr nominal - Vertical Wire Flame Test)\u003cbr\u003e AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements).\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e750 AWG\u003cbr\u003e\u003cstrong\u003eNo of Strand:\u003c\/strong\u003e 58\u003cbr\u003e\u003cstrong\u003eDiameter Over Conductor: \u003c\/strong\u003e0.908inch\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation:\u003c\/strong\u003e  1.416inch\u003cbr\u003e\u003cstrong\u003eInsulation Thickness:\u003c\/strong\u003e 220mil\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation Shield:\u003c\/strong\u003e 1.476inch\u003cbr\u003e\u003cstrong\u003eGround Size:\u003c\/strong\u003e 2 AWG\u003cbr\u003e\u003cstrong\u003eInner Jacket Thickness:\u003c\/strong\u003e 125mil\u003cbr\u003e\u003cstrong\u003eDia. Over Armour:\u003c\/strong\u003e 3.860inch\u003cbr\u003e\u003cstrong\u003eOverall Jacket Thickness:\u003c\/strong\u003e 85mil\u003cbr\u003e\u003cstrong\u003eApprox.OD: \u003c\/strong\u003e4.030inch\u003cbr\u003e\u003cstrong\u003eApprox.Weight(lb\/1000)\u003c\/strong\u003e: 7182\u003cbr\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"width: 325.114px; height: 35.5966px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e669887\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":67614236344689,"sku":"NNC669887","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitleddesign_1_d538a474-ff80-4bee-bd1d-2905d73cabf0.png?v=1790838400"}],"url":"https:\/\/nassaunationalcable.com\/collections\/hvteck-aluminum-3-c-220-mil-nlepr-ts-aia-15kv-133-il-red-pvc-jacket-csa.oembed","provider":"NassauNationalCable","version":"1.0","type":"link"}