{"title":"HVTECK Aluminum 3\/C 115 mil NLEPR TS AIA 5kV 133% IL Orange PVC Jacket CSA","description":null,"products":[{"product_id":"hvteck-aluminum-3-c-115-mil-nlepr-ts-aia-5kv-133-il-orange-pvc-jacket-csa","title":"2 AWG 3C HVTECK Aluminum 115 mil NLEPR TS AIA 5kV 133% IL Orange PVC Jacket CSA","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC26162_1.pdf?v=1790060425\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e2 AWG 3C HVTECK Aluminum 115 mil NLEPR TS AIA 5kV 133% IL Orange PVC Jacket CSA\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplication:\u003c\/h3\u003e\n\u003cp\u003eThe  5kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications. Rated FT4, -40°C, Hazardous Locations (HL). These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lbs \/FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids and are flame retardant. 3 Conductor, 115 Mils No Lead Ethylene Propylene Rubber (NL-EPR), 133% Insulation Level, Tape Shield, Polyvinyl Chloride (PVC) Inner Jacket, Aluminum Interlocked Armour (AIA), Polyvinyl Chloride (PVC) Jacket.\u003c\/p\u003e\n\u003ch3\u003eAlso known as :\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e2 AWG 3C 5kV HVTECK Cable, 2 AWG 3C \u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e5kV HVTECK Armoured Cable, 2 AWG 3C 5kV CSA Armoured Cable, 2 AWG 3C 5kV Medium Voltage Cable, 2 AWG 3C 5kV MV Power Cable, 2 AWG 3C 5kV Shielded Power Cable, 2 AWG 3C  5kV 3\/C Aluminum Cable, 2 AWG 3C 3\/C Aluminum Medium Voltage Cable, 2-3C Aluminum Armoured MV Cable, 2-3C Aluminum Interlocked Armour Cable, 2-3C AIA Armoured Cable, 2-3C 5kV AIA Cable, 2-3C NL-EPR Insulated Cable, 2-3C 115 mil EPR Cable, 2-3C 133% Insulation Level Cable,2-3C Copper Tape Shielded Cable, 2-3C PVC Jacketed Armoured Cable,2-3C  Orange PVC Jacket Cable, 2-3C CSA HVTECK Cable.\u003c\/p\u003e\n\u003ch3\u003eConstruction:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Class B compact stranded 8000 Series aluminum per ASTM B800 and ASTM B836\u003cbr\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e: Semi-conducting cross-linked copolymer; A conductor separator is used for cable size larger than or equal to 500 Kcmil\u003cbr\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: 115 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% insulation level\u003cbr\u003e\u003cstrong\u003eInsulation Shield\u003c\/strong\u003e: Strippable semi-conducting cross-linked copolymer\u003cbr\u003e\u003cstrong\u003eCopper Tape Shield\u003c\/strong\u003e: Helically wrapped 5 mil copper tape with 25% overlap\u003cbr\u003e\u003cstrong\u003eFiller\u003c\/strong\u003e: Interstices filled with non-hydroscoping\/non-wicking fillers\u003cbr\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e Class B compressed stranded bare copper ground per ASTM B3 and ASTM B8\u003cbr\u003e\u003cstrong\u003eBinder\u003c\/strong\u003e: Polypropylene tape\u003cbr\u003e\u003cstrong\u003eInner Jacket\u003c\/strong\u003e: PVC inner jacket\u003cbr\u003e\u003cstrong\u003eArmour\u003c\/strong\u003e: Aluminum Interlocked Armour (AIA)\u003cbr\u003e\u003cstrong\u003eOverall Jacket\u003c\/strong\u003e: Orange Polyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e ASTM B801 Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy\u003cbr\u003e ASTM B836 Compact Rounded Stranded Aluminum Conductors\u003cbr\u003e CSA C22.2 No. 174 Cables in Hazardous Locations\u003cbr\u003e CSA C22.2 No. 2556 \u0026amp; No. 0.3 Wire and Cable Test Methods\u003cbr\u003e CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV\u003cbr\u003e CSA C68.3 Shielded \u0026amp; Concentric Neutral Power Cable - 5 to 46 kV\u003cbr\u003e CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating\u003cbr\u003e CSA HL - for Hazardous Locations rating\u003cbr\u003e CSA SUN RES - for Sunlight Resistant rating\u003cbr\u003e ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable\u003cbr\u003e ICEA T-29-520 Flame Test (210,000 BTU\/Hr)\u003cbr\u003e IEEE 383 Flame Test (70,000 btu)\u003cbr\u003e IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003cbr\u003e FT1 Flame Test (1,706 BTU\/Hr nominal - Vertical Wire Flame Test)\u003cbr\u003e AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through  46KV (Qualification Test Requirements)\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSPECIFICATIONS:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor size: \u003c\/strong\u003e2 AWG\u003cbr\u003e\u003cstrong\u003eStrand: \u003c\/strong\u003e7\u003cbr\u003e\u003cstrong\u003eDiameter Over Conductor: \u003c\/strong\u003e0.268inch\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation: \u003c\/strong\u003e0.536inch\u003cbr\u003e\u003cstrong\u003eInsulation Thickness: \u003c\/strong\u003e115mil\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation Shield: \u003c\/strong\u003e0.596 inch\u003cbr\u003e\u003cstrong\u003eGround \u003c\/strong\u003e\u003cstrong\u003eSize: \u003c\/strong\u003e8AWG\u003cbr\u003e\u003cstrong\u003eInner Jacket Thickness: \u003c\/strong\u003e80 mil\u003cbr\u003e\u003cstrong\u003eDiameter. Over Armour: \u003c\/strong\u003e1.847inch\u003cbr\u003e\u003cstrong\u003eOverall Jacket Thickness: \u003c\/strong\u003e60mil\u003cbr\u003e\u003cstrong\u003eApprox.OD: \u003c\/strong\u003e1.967inch\u003cbr\u003e\u003cstrong\u003eApprox. \u003c\/strong\u003e\u003cstrong\u003eWeight(lb\/1000ft): \u003c\/strong\u003e1499\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":64609454096753,"sku":"NNC2593","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_16_1f748ac1-19f1-4f85-94c2-51d8cc5cb459.png?v=1790055325"},{"product_id":"1-awg-3c-hvteck-aluminum-115-mil-nlepr-ts-aia-5kv-133-il-orange-pvc-jacket-csa","title":"1 AWG 3C HVTECK Aluminum 115 mil NLEPR TS AIA 5kV 133% IL Orange PVC Jacket CSA","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC26162_1.pdf?v=1790060425\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e1 AWG 3C HVTECK Aluminum 115 mil NLEPR TS AIA 5kV 133% IL Orange PVC Jacket CSA\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplication:\u003c\/h3\u003e\n\u003cp\u003eThe  5kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications. Rated FT4, -40°C, Hazardous Locations (HL). These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lbs \/FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids and are flame retardant. 3 Conductor, 115 Mils No Lead Ethylene Propylene Rubber (NL-EPR), 133% Insulation Level, Tape Shield, Polyvinyl Chloride (PVC) Inner Jacket, Aluminum Interlocked Armour (AIA), Polyvinyl Chloride (PVC) Jacket.\u003c\/p\u003e\n\u003ch3\u003eAlso known as :\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e1 AWG 3C 5kV HVTECK Cable,1 AWG 3C \u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e5kV HVTECK Armoured Cable,1 AWG 3C 5kV CSA Armoured Cable, 1 AWG 3C 5kV Medium Voltage Cable,1 AWG 3C 5kV MV Power Cable,1 AWG 3C 5kV Shielded Power Cable,1 AWG 3C  5kV 3\/C Aluminum Cable, 1 AWG 3C 3\/C Aluminum Medium Voltage Cable,1-3C Aluminum Armoured MV Cable, 1-3C Aluminum Interlocked Armour Cable,1-3C AIA Armoured Cable, 1-3C 5kV AIA Cable, 1-3C NL-EPR Insulated Cable,1-3C 115 mil EPR Cable,1-3C 133% Insulation Level Cable, 1-3C Copper Tape Shielded Cable, 1-3C PVC Jacketed Armoured Cable,1-3C  Orange PVC Jacket Cable, 1-3C CSA HVTECK Cable.\u003c\/p\u003e\n\u003ch3\u003eConstruction:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Class B compact stranded 8000 Series aluminum per ASTM B800 and ASTM B836\u003cbr\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e: Semi-conducting cross-linked copolymer; A conductor separator is used for cable size larger than or equal to 500 Kcmil\u003cbr\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: 115 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% insulation level\u003cbr\u003e\u003cstrong\u003eInsulation Shield\u003c\/strong\u003e: Strippable semi-conducting cross-linked copolymer\u003cbr\u003e\u003cstrong\u003eCopper Tape Shield\u003c\/strong\u003e: Helically wrapped 5 mil copper tape with 25% overlap\u003cbr\u003e\u003cstrong\u003eFiller\u003c\/strong\u003e: Interstices filled with non-hydroscoping\/non-wicking fillers\u003cbr\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e Class B compressed stranded bare copper ground per ASTM B3 and ASTM B8\u003cbr\u003e\u003cstrong\u003eBinder\u003c\/strong\u003e: Polypropylene tape\u003cbr\u003e\u003cstrong\u003eInner Jacket\u003c\/strong\u003e: PVC inner jacket\u003cbr\u003e\u003cstrong\u003eArmour\u003c\/strong\u003e: Aluminum Interlocked Armour (AIA)\u003cbr\u003e\u003cstrong\u003eOverall Jacket\u003c\/strong\u003e: Orange Polyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e ASTM B801 Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy\u003cbr\u003e ASTM B836 Compact Rounded Stranded Aluminum Conductors\u003cbr\u003e CSA C22.2 No. 174 Cables in Hazardous Locations\u003cbr\u003e CSA C22.2 No. 2556 \u0026amp; No. 0.3 Wire and Cable Test Methods\u003cbr\u003e CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV\u003cbr\u003e CSA C68.3 Shielded \u0026amp; Concentric Neutral Power Cable - 5 to 46 kV\u003cbr\u003e CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating\u003cbr\u003e CSA HL - for Hazardous Locations rating\u003cbr\u003e CSA SUN RES - for Sunlight Resistant rating\u003cbr\u003e ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable\u003cbr\u003e ICEA T-29-520 Flame Test (210,000 BTU\/Hr)\u003cbr\u003e IEEE 383 Flame Test (70,000 btu)\u003cbr\u003e IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003cbr\u003e FT1 Flame Test (1,706 BTU\/Hr nominal - Vertical Wire Flame Test)\u003cbr\u003e AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through  46KV (Qualification Test Requirements)\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSPECIFICATIONS:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor size: \u003c\/strong\u003e1 AWG\u003cbr\u003e\u003cstrong\u003eStrand: \u003c\/strong\u003e19\u003cbr\u003e\u003cstrong\u003eDiameter Over Conductor:\u003c\/strong\u003e 0.298inch\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation:\u003c\/strong\u003e  0.566inch\u003cbr\u003e\u003cstrong\u003eInsulation Thickness: \u003c\/strong\u003e115mil\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation Shield: \u003c\/strong\u003e0.626inch\u003cbr\u003e\u003cstrong\u003eGround \u003c\/strong\u003e\u003cstrong\u003eSize: \u003c\/strong\u003e6AWG\u003cbr\u003e\u003cstrong\u003eInner Jacket Thickness: \u003c\/strong\u003e80mil\u003cbr\u003e\u003cstrong\u003eDiameter. Over Armour: \u003c\/strong\u003e1.911inch\u003cbr\u003e\u003cstrong\u003eOverall Jacket Thickness: \u003c\/strong\u003e60mil\u003cbr\u003e\u003cstrong\u003eApprox.OD:\u003c\/strong\u003e  2.031inch\u003cbr\u003e\u003cstrong\u003eApprox. \u003c\/strong\u003e\u003cstrong\u003eWeight(lb\/1000ft): \u003c\/strong\u003e1625\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":64644318396785,"sku":"NNC1852","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_16_1f748ac1-19f1-4f85-94c2-51d8cc5cb459.png?v=1790055325"},{"product_id":"1-0-awg-3c-hvteck-aluminum-115-mil-nlepr-ts-aia-5kv-133-il-orange-pvc-jacket-csa","title":"1\/0 AWG 3C HVTECK Aluminum 115 mil NLEPR TS AIA 5kV 133% IL Orange PVC Jacket CSA","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC26162_1.pdf?v=1790060425\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e1\/0 AWG 3C HVTECK Aluminum 115 mil NLEPR TS AIA 5kV 133% IL Orange PVC Jacket CSA\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplication:\u003c\/h3\u003e\n\u003cp\u003eThe  5kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications. Rated FT4, -40°C, Hazardous Locations (HL). These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lbs \/FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids and are flame retardant. 3 Conductor, 115 Mils No Lead Ethylene Propylene Rubber (NL-EPR), 133% Insulation Level, Tape Shield, Polyvinyl Chloride (PVC) Inner Jacket, Aluminum Interlocked Armour (AIA), Polyvinyl Chloride (PVC) Jacket.\u003c\/p\u003e\n\u003ch3\u003eAlso known as :\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e1\/0 AWG 3C 5kV HVTECK Cable,1\/0 AWG 3C \u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e5kV HVTECK Armoured Cable,1\/0AWG 3C 5kV CSA Armoured Cable, 1\/0 AWG 3C 5kV Medium Voltage Cable,1\/0 AWG 3C 5kV MV Power Cable,1\/0 AWG 3C 5kV Shielded Power Cable,1\/0 AWG 3C  5kV 3\/C Aluminum Cable, 1\/0 AWG 3C 3\/C Aluminum Medium Voltage Cable,1-3C Aluminum Armoured MV Cable, 1\/0-3C Aluminum Interlocked Armour Cable,1\/0-3C AIA Armoured Cable, 1\/0-3C 5kV AIA Cable, 1\/0-3C NL-EPR Insulated Cable,1\/0-3C 115 mil EPR Cable,1\/0-3C 133% Insulation Level Cable, 1\/0-3C Copper Tape Shielded Cable, 1\/0-3C PVC Jacketed Armoured Cable,1\/0-3C  Orange PVC Jacket Cable, 1\/0-3C CSA HVTECK Cable.\u003c\/p\u003e\n\u003ch3\u003eConstruction:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Class B compact stranded 8000 Series aluminum per ASTM B800 and ASTM B836\u003cbr\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e: Semi-conducting cross-linked copolymer; A conductor separator is used for cable size larger than or equal to 500 Kcmil\u003cbr\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: 115 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% insulation level\u003cbr\u003e\u003cstrong\u003eInsulation Shield\u003c\/strong\u003e: Strippable semi-conducting cross-linked copolymer\u003cbr\u003e\u003cstrong\u003eCopper Tape Shield\u003c\/strong\u003e: Helically wrapped 5 mil copper tape with 25% overlap\u003cbr\u003e\u003cstrong\u003eFiller\u003c\/strong\u003e: Interstices filled with non-hydroscoping\/non-wicking fillers\u003cbr\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e Class B compressed stranded bare copper ground per ASTM B3 and ASTM B8\u003cbr\u003e\u003cstrong\u003eBinder\u003c\/strong\u003e: Polypropylene tape\u003cbr\u003e\u003cstrong\u003eInner Jacket\u003c\/strong\u003e: PVC inner jacket\u003cbr\u003e\u003cstrong\u003eArmour\u003c\/strong\u003e: Aluminum Interlocked Armour (AIA)\u003cbr\u003e\u003cstrong\u003eOverall Jacket\u003c\/strong\u003e: Orange Polyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e ASTM B801 Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy\u003cbr\u003e ASTM B836 Compact Rounded Stranded Aluminum Conductors\u003cbr\u003e CSA C22.2 No. 174 Cables in Hazardous Locations\u003cbr\u003e CSA C22.2 No. 2556 \u0026amp; No. 0.3 Wire and Cable Test Methods\u003cbr\u003e CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV\u003cbr\u003e CSA C68.3 Shielded \u0026amp; Concentric Neutral Power Cable - 5 to 46 kV\u003cbr\u003e CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating\u003cbr\u003e CSA HL - for Hazardous Locations rating\u003cbr\u003e CSA SUN RES - for Sunlight Resistant rating\u003cbr\u003e ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable\u003cbr\u003e ICEA T-29-520 Flame Test (210,000 BTU\/Hr)\u003cbr\u003e IEEE 383 Flame Test (70,000 btu)\u003cbr\u003e IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003cbr\u003e FT1 Flame Test (1,706 BTU\/Hr nominal - Vertical Wire Flame Test)\u003cbr\u003e AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through  46KV (Qualification Test Requirements)\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSPECIFICATIONS:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor size: \u003c\/strong\u003e1\/0 AWG\u003cbr\u003e\u003cstrong\u003eStrand: \u003c\/strong\u003e19\u003cbr\u003e\u003cstrong\u003eDiameter Over Conductor:\u003c\/strong\u003e 0.336inch\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation: \u003c\/strong\u003e0.604inch\u003cbr\u003e\u003cstrong\u003eInsulation Thickness: \u003c\/strong\u003e115mil\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation Shield: \u003c\/strong\u003e0.664inch\u003cbr\u003e\u003cstrong\u003eGround \u003c\/strong\u003e\u003cstrong\u003eSize: \u003c\/strong\u003e6AWG\u003cbr\u003e\u003cstrong\u003eInner Jacket Thickness: \u003c\/strong\u003e80mil\u003cbr\u003e\u003cstrong\u003eDiameter. Over Armour: \u003c\/strong\u003e1.993inch\u003cbr\u003e\u003cstrong\u003eOverall Jacket Thickness: \u003c\/strong\u003e60mil\u003cbr\u003e\u003cstrong\u003eApprox.OD:\u003c\/strong\u003e 2.113inch\u003cbr\u003e\u003cstrong\u003eApprox. \u003c\/strong\u003e\u003cstrong\u003eWeight(lb\/1000ft):\u003c\/strong\u003e1776\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":64644346118513,"sku":"NNC2456","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_16_1f748ac1-19f1-4f85-94c2-51d8cc5cb459.png?v=1790055325"},{"product_id":"2-0-awg-3c-hvteck-aluminum-115-mil-nlepr-ts-aia-5kv-133-il-orange-pvc-jacket-csa","title":"2\/0 AWG 3C HVTECK Aluminum 115 mil NLEPR TS AIA 5kV 133% IL Orange PVC Jacket CSA","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC26162_1.pdf?v=1790060425\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e2\/0 AWG 3C HVTECK Aluminum 115 mil NLEPR TS AIA 5kV 133% IL Orange PVC Jacket CSA\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplication:\u003c\/h3\u003e\n\u003cp\u003eThe  5kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications. Rated FT4, -40°C, Hazardous Locations (HL). These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lbs \/FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids and are flame retardant. 3 Conductor, 115 Mils No Lead Ethylene Propylene Rubber (NL-EPR), 133% Insulation Level, Tape Shield, Polyvinyl Chloride (PVC) Inner Jacket, Aluminum Interlocked Armour (AIA), Polyvinyl Chloride (PVC) Jacket.\u003c\/p\u003e\n\u003ch3\u003eAlso known as :\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e2\/0 AWG 3C 5kV HVTECK Cable,2\/0 AWG 3C \u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e5kV HVTECK Armoured Cable,2\/0AWG 3C 5kV CSA Armoured Cable, 2\/0 AWG 3C 5kV Medium Voltage Cable,2\/0 AWG 3C 5kV MV Power Cable,2\/0 AWG 3C 5kV Shielded Power Cable,2\/0 AWG 3C  5kV 3\/C Aluminum Cable, 2\/0 AWG 3C 3\/C Aluminum Medium Voltage Cable,2\/0-3C Aluminum Armoured MV Cable, 2\/0-3C Aluminum Interlocked Armour Cable,2\/0-3C AIA Armoured Cable, 2\/0-3C 5kV AIA Cable, 2\/0-3C NL-EPR Insulated Cable,2\/0-3C 115 mil EPR Cable,2\/0-3C 133% Insulation Level Cable, 2\/0-3C Copper Tape Shielded Cable, 2\/0-3C PVC Jacketed Armoured Cable,2\/0-3C Orange PVC Jacket Cable,2\/0-3C CSA HVTECK Cable.\u003c\/p\u003e\n\u003ch3\u003eConstruction:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Class B compact stranded 8000 Series aluminum per ASTM B800 and ASTM B836\u003cbr\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e: Semi-conducting cross-linked copolymer; A conductor separator is used for cable size larger than or equal to 500 Kcmil\u003cbr\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: 115 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% insulation level\u003cbr\u003e\u003cstrong\u003eInsulation Shield\u003c\/strong\u003e: Strippable semi-conducting cross-linked copolymer\u003cbr\u003e\u003cstrong\u003eCopper Tape Shield\u003c\/strong\u003e: Helically wrapped 5 mil copper tape with 25% overlap\u003cbr\u003e\u003cstrong\u003eFiller\u003c\/strong\u003e: Interstices filled with non-hydroscoping\/non-wicking fillers\u003cbr\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e Class B compressed stranded bare copper ground per ASTM B3 and ASTM B8\u003cbr\u003e\u003cstrong\u003eBinder\u003c\/strong\u003e: Polypropylene tape\u003cbr\u003e\u003cstrong\u003eInner Jacket\u003c\/strong\u003e: PVC inner jacket\u003cbr\u003e\u003cstrong\u003eArmour\u003c\/strong\u003e: Aluminum Interlocked Armour (AIA)\u003cbr\u003e\u003cstrong\u003eOverall Jacket\u003c\/strong\u003e: Orange Polyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e ASTM B801 Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy\u003cbr\u003e ASTM B836 Compact Rounded Stranded Aluminum Conductors\u003cbr\u003e CSA C22.2 No. 174 Cables in Hazardous Locations\u003cbr\u003e CSA C22.2 No. 2556 \u0026amp; No. 0.3 Wire and Cable Test Methods\u003cbr\u003e CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV\u003cbr\u003e CSA C68.3 Shielded \u0026amp; Concentric Neutral Power Cable - 5 to 46 kV\u003cbr\u003e CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating\u003cbr\u003e CSA HL - for Hazardous Locations rating\u003cbr\u003e CSA SUN RES - for Sunlight Resistant rating\u003cbr\u003e ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable\u003cbr\u003e ICEA T-29-520 Flame Test (210,000 BTU\/Hr)\u003cbr\u003e IEEE 383 Flame Test (70,000 btu)\u003cbr\u003e IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003cbr\u003e FT1 Flame Test (1,706 BTU\/Hr nominal - Vertical Wire Flame Test)\u003cbr\u003e AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through  46KV (Qualification Test Requirements)\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSPECIFICATIONS:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor size:  \u003c\/strong\u003e2\/0AWG\u003cbr\u003e\u003cstrong\u003eStrand: \u003c\/strong\u003e19\u003cbr\u003e\u003cstrong\u003eDiameter Over Conductor:\u003c\/strong\u003e 0.376inch\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation: \u003c\/strong\u003e0.644inch\u003cbr\u003e\u003cstrong\u003eInsulation Thickness: \u003c\/strong\u003e115mil\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation Shield: \u003c\/strong\u003e0.704inch\u003cbr\u003e\u003cstrong\u003eGround \u003c\/strong\u003e\u003cstrong\u003eSize: \u003c\/strong\u003e6AWG\u003cbr\u003e\u003cstrong\u003eInner Jacket Thickness: \u003c\/strong\u003e110mil\u003cbr\u003e\u003cstrong\u003eDiameter. Over Armour: \u003c\/strong\u003e2.140inch\u003cbr\u003e\u003cstrong\u003eOverall Jacket Thickness: \u003c\/strong\u003e60mil\u003cbr\u003e\u003cstrong\u003eApprox.OD:\u003c\/strong\u003e 2.260inch\u003cbr\u003e\u003cstrong\u003eApprox. \u003c\/strong\u003e\u003cstrong\u003eWeight(lb\/1000ft): \u003c\/strong\u003e2072\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":64644378394993,"sku":"NNC2671","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_16_1f748ac1-19f1-4f85-94c2-51d8cc5cb459.png?v=1790055325"},{"product_id":"3-0-awg-3c-hvteck-aluminum-115-mil-nlepr-ts-aia-5kv-133-il-orange-pvc-jacket-csa","title":"3\/0 AWG 3C HVTECK Aluminum 115 mil NLEPR TS AIA 5kV 133% IL Orange PVC Jacket CSA","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC26162_1.pdf?v=1790060425\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e3\/0 AWG 3C HVTECK Aluminum 115 mil NLEPR TS AIA 5kV 133% IL Orange PVC Jacket CSA\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplication:\u003c\/h3\u003e\n\u003cp\u003eThe  5kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications. Rated FT4, -40°C, Hazardous Locations (HL). These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lbs \/FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids and are flame retardant. 3 Conductor, 115 Mils No Lead Ethylene Propylene Rubber (NL-EPR), 133% Insulation Level, Tape Shield, Polyvinyl Chloride (PVC) Inner Jacket, Aluminum Interlocked Armour (AIA), Polyvinyl Chloride (PVC) Jacket.\u003c\/p\u003e\n\u003ch3\u003eAlso known as :\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e3\/0 AWG 3C 5kV HVTECK Cable,3\/0 AWG 3C \u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e5kV HVTECK Armoured Cable,3\/0AWG 3C 5kV CSA Armoured Cable, 3\/0 AWG 3C 5kV Medium Voltage Cable,3\/0 AWG 3C 5kV MV Power Cable,3\/0 AWG 3C 5kV Shielded Power Cable,3\/0 AWG 3C  5kV 3\/C Aluminum Cable, 3\/0 AWG 3C 3\/C Aluminum Medium Voltage Cable,3\/0-3C Aluminum Armoured MV Cable,3\/0-3C Aluminum Interlocked Armour Cable,3\/0-3C AIA Armoured Cable, 3\/0-3C 5kV AIA Cable, 3\/0-3C NL-EPR Insulated Cable,3\/0-3C 115 mil EPR Cable,3\/0-3C 133% Insulation Level Cable, 3\/0-3C Copper Tape Shielded Cable, 3\/0-3C PVC Jacketed Armoured Cable,3\/0-3C Orange PVC Jacket Cable,3\/0-3C CSA HVTECK Cable.\u003c\/p\u003e\n\u003ch3\u003eConstruction:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Class B compact stranded 8000 Series aluminum per ASTM B800 and ASTM B836\u003cbr\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e: Semi-conducting cross-linked copolymer; A conductor separator is used for cable size larger than or equal to 500 Kcmil\u003cbr\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: 115 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% insulation level\u003cbr\u003e\u003cstrong\u003eInsulation Shield\u003c\/strong\u003e: Strippable semi-conducting cross-linked copolymer\u003cbr\u003e\u003cstrong\u003eCopper Tape Shield\u003c\/strong\u003e: Helically wrapped 5 mil copper tape with 25% overlap\u003cbr\u003e\u003cstrong\u003eFiller\u003c\/strong\u003e: Interstices filled with non-hydroscoping\/non-wicking fillers\u003cbr\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e Class B compressed stranded bare copper ground per ASTM B3 and ASTM B8\u003cbr\u003e\u003cstrong\u003eBinder\u003c\/strong\u003e: Polypropylene tape\u003cbr\u003e\u003cstrong\u003eInner Jacket\u003c\/strong\u003e: PVC inner jacket\u003cbr\u003e\u003cstrong\u003eArmour\u003c\/strong\u003e: Aluminum Interlocked Armour (AIA)\u003cbr\u003e\u003cstrong\u003eOverall Jacket\u003c\/strong\u003e: Orange Polyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e ASTM B801 Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy\u003cbr\u003e ASTM B836 Compact Rounded Stranded Aluminum Conductors\u003cbr\u003e CSA C22.2 No. 174 Cables in Hazardous Locations\u003cbr\u003e CSA C22.2 No. 2556 \u0026amp; No. 0.3 Wire and Cable Test Methods\u003cbr\u003e CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV\u003cbr\u003e CSA C68.3 Shielded \u0026amp; Concentric Neutral Power Cable - 5 to 46 kV\u003cbr\u003e CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating\u003cbr\u003e CSA HL - for Hazardous Locations rating\u003cbr\u003e CSA SUN RES - for Sunlight Resistant rating\u003cbr\u003e ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable\u003cbr\u003e ICEA T-29-520 Flame Test (210,000 BTU\/Hr)\u003cbr\u003e IEEE 383 Flame Test (70,000 btu)\u003cbr\u003e IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003cbr\u003e FT1 Flame Test (1,706 BTU\/Hr nominal - Vertical Wire Flame Test)\u003cbr\u003e AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through  46KV (Qualification Test Requirements)\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSPECIFICATIONS:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor size:  \u003c\/strong\u003e3\/0AWG\u003cbr\u003e\u003cstrong\u003eStrand: \u003c\/strong\u003e19\u003cbr\u003e\u003cstrong\u003eDiameter Over Conductor:\u003c\/strong\u003e 0.422inch\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation:  \u003c\/strong\u003e0.690inch\u003cbr\u003e\u003cstrong\u003eInsulation Thickness: \u003c\/strong\u003e115mil\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation Shield: \u003c\/strong\u003e 0.750inch\u003cbr\u003e\u003cstrong\u003eGround \u003c\/strong\u003e\u003cstrong\u003eSize:  \u003c\/strong\u003e6AWG\u003cbr\u003e\u003cstrong\u003eInner Jacket Thickness:\u003c\/strong\u003e 110mil\u003cbr\u003e\u003cstrong\u003eDiameter. Over Armour:\u003c\/strong\u003e2.239inch\u003cbr\u003e\u003cstrong\u003eOverall Jacket Thickness: \u003c\/strong\u003e60mil\u003cbr\u003e\u003cstrong\u003eApprox.OD:\u003c\/strong\u003e 2.359inch\u003cbr\u003e\u003cstrong\u003eApprox. \u003c\/strong\u003e\u003cstrong\u003eWeight(lb\/1000ft): \u003c\/strong\u003e2284\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":64644521460081,"sku":"NNC9635","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_16_1f748ac1-19f1-4f85-94c2-51d8cc5cb459.png?v=1790055325"},{"product_id":"4-0-awg-3c-hvteck-aluminum-115-mil-nlepr-ts-aia-5kv-133-il-orange-pvc-jacket-csa","title":"4\/0 AWG 3C HVTECK Aluminum 115 mil NLEPR TS AIA 5kV 133% IL Orange PVC Jacket CSA","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC26162_1.pdf?v=1790060425\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e4\/0 AWG 3C HVTECK Aluminum 115 mil NLEPR TS AIA 5kV 133% IL Orange PVC Jacket CSA\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplication:\u003c\/h3\u003e\n\u003cp\u003eThe  5kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications. Rated FT4, -40°C, Hazardous Locations (HL). These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lbs \/FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids and are flame retardant. 3 Conductor, 115 Mils No Lead Ethylene Propylene Rubber (NL-EPR), 133% Insulation Level, Tape Shield, Polyvinyl Chloride (PVC) Inner Jacket, Aluminum Interlocked Armour (AIA), Polyvinyl Chloride (PVC) Jacket.\u003c\/p\u003e\n\u003ch3\u003eAlso known as :\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e4\/0 AWG 3C 5kV HVTECK Cable,4\/0 AWG 3C \u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e5kV HVTECK Armoured Cable,4\/0AWG 3C 5kV CSA Armoured Cable, 4\/0 AWG 3C 5kV Medium Voltage Cable,4\/0 AWG 3C 5kV MV Power Cable,4\/0 AWG 3C 5kV Shielded Power Cable,4\/0 AWG 3C 5kV 3\/C Aluminum Cable, 4\/0 AWG 3C 3\/C Aluminum Medium Voltage Cable,4\/0-3C Aluminum Armoured MV Cable, 4\/0-3C Aluminum Interlocked Armour Cable,4\/0-3C AIA Armoured Cable, 4\/0-3C 5kV AIA Cable, 4\/0-3C NL-EPR Insulated Cable,4\/0-3C 115 mil EPR Cable,4\/0-3C 133% Insulation Level Cable, 4\/0-3C Copper Tape Shielded Cable, 4\/0-3C PVC Jacketed Armoured Cable,4\/0-3C Orange PVC Jacket Cable,4\/0-3C CSA HVTECK Cable.\u003c\/p\u003e\n\u003ch3\u003eConstruction:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Class B compact stranded 8000 Series aluminum per ASTM B800 and ASTM B836\u003cbr\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e: Semi-conducting cross-linked copolymer; A conductor separator is used for cable size larger than or equal to 500 Kcmil\u003cbr\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: 115 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% insulation level\u003cbr\u003e\u003cstrong\u003eInsulation Shield\u003c\/strong\u003e: Strippable semi-conducting cross-linked copolymer\u003cbr\u003e\u003cstrong\u003eCopper Tape Shield\u003c\/strong\u003e: Helically wrapped 5 mil copper tape with 25% overlap\u003cbr\u003e\u003cstrong\u003eFiller\u003c\/strong\u003e: Interstices filled with non-hydroscoping\/non-wicking fillers\u003cbr\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e Class B compressed stranded bare copper ground per ASTM B3 and ASTM B8\u003cbr\u003e\u003cstrong\u003eBinder\u003c\/strong\u003e: Polypropylene tape\u003cbr\u003e\u003cstrong\u003eInner Jacket\u003c\/strong\u003e: PVC inner jacket\u003cbr\u003e\u003cstrong\u003eArmour\u003c\/strong\u003e: Aluminum Interlocked Armour (AIA)\u003cbr\u003e\u003cstrong\u003eOverall Jacket\u003c\/strong\u003e: Orange Polyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e ASTM B801 Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy\u003cbr\u003e ASTM B836 Compact Rounded Stranded Aluminum Conductors\u003cbr\u003e CSA C22.2 No. 174 Cables in Hazardous Locations\u003cbr\u003e CSA C22.2 No. 2556 \u0026amp; No. 0.3 Wire and Cable Test Methods\u003cbr\u003e CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV\u003cbr\u003e CSA C68.3 Shielded \u0026amp; Concentric Neutral Power Cable - 5 to 46 kV\u003cbr\u003e CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating\u003cbr\u003e CSA HL - for Hazardous Locations rating\u003cbr\u003e CSA SUN RES - for Sunlight Resistant rating\u003cbr\u003e ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable\u003cbr\u003e ICEA T-29-520 Flame Test (210,000 BTU\/Hr)\u003cbr\u003e IEEE 383 Flame Test (70,000 btu)\u003cbr\u003e IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003cbr\u003e FT1 Flame Test (1,706 BTU\/Hr nominal - Vertical Wire Flame Test)\u003cbr\u003e AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through  46KV (Qualification Test Requirements)\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSPECIFICATIONS:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor size: \u003c\/strong\u003e 4\/0AWG\u003cbr\u003e\u003cstrong\u003eStrand: \u003c\/strong\u003e19\u003cbr\u003e\u003cstrong\u003eDiameter Over Conductor: \u003c\/strong\u003e0.474inch\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation: \u003c\/strong\u003e0.742inch\u003cbr\u003e\u003cstrong\u003eInsulation Thickness: \u003c\/strong\u003e115mil\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation Shield: \u003c\/strong\u003e0.802inch\u003cbr\u003e\u003cstrong\u003eGround \u003c\/strong\u003e\u003cstrong\u003eSize:  \u003c\/strong\u003e6AWG\u003cbr\u003e\u003cstrong\u003eInner Jacket Thickness:\u003c\/strong\u003e 110mil\u003cbr\u003e\u003cstrong\u003eDiameter. Over Armour: \u003c\/strong\u003e2.352inch\u003cbr\u003e\u003cstrong\u003eOverall Jacket Thickness: \u003c\/strong\u003e75mil\u003cbr\u003e\u003cstrong\u003eApprox.OD: \u003c\/strong\u003e2.502inch\u003cbr\u003e\u003cstrong\u003eApprox. \u003c\/strong\u003e\u003cstrong\u003eWeight(lb\/1000ft): \u003c\/strong\u003e2613\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":64644595417457,"sku":"NNC3964","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_16_1f748ac1-19f1-4f85-94c2-51d8cc5cb459.png?v=1790055325"},{"product_id":"250-mcm-3c-hvteck-aluminum-115-mil-nlepr-ts-aia-5kv-133-il-orange-pvc-jacket-csa","title":"250 MCM 3C HVTECK Aluminum 115 mil NLEPR TS AIA 5kV 133% IL Orange PVC Jacket CSA","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC26162_1.pdf?v=1790060425\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e250 MCM 3C HVTECK Aluminum 115 mil NLEPR TS AIA 5kV 133% IL Orange PVC Jacket CSA\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplication:\u003c\/h3\u003e\n\u003cp\u003eThe  5kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications. Rated FT4, -40°C, Hazardous Locations (HL). These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lbs \/FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids and are flame retardant. 3 Conductor, 115 Mils No Lead Ethylene Propylene Rubber (NL-EPR), 133% Insulation Level, Tape Shield, Polyvinyl Chloride (PVC) Inner Jacket, Aluminum Interlocked Armour (AIA), Polyvinyl Chloride (PVC) Jacket.\u003c\/p\u003e\n\u003ch3\u003eAlso known as :\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e250 MNM 3C 5kV HVTECK Cable, 250 MNM 3C \u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e5kV HVTECK Armoured Cable, 250 MNM 3C 5kV CSA Armoured Cable, 250 MNM 3C 5kV Medium Voltage Cable, 250 MNM 3C 5kV MV Power Cable, 250 MNM 3C 5kV Shielded Power Cable, 250 MNM 3C 5kV 3\/C Aluminum Cable, 250 MNM 3C 3\/C Aluminum Medium Voltage Cable,250-3C Aluminum Armoured MV Cable, 250-3C Aluminum Interlocked Armour Cable, 250-3C AIA Armoured Cable, 250-3C 5kV AIA Cable, 250-3C NL-EPR Insulated Cable, 250-3C 115 mil EPR Cable, 250-3C 133% Insulation Level Cable, 250-3C-3C Copper Tape Shielded Cable, 250-3C PVC Jacketed Armoured Cable, 250-3C Orange PVC Jacket Cable, 250-3C CSA HVTECK Cable.\u003c\/p\u003e\n\u003ch3\u003eConsruction:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Class B compact stranded 8000 Series aluminum per ASTM B800 and ASTM B836\u003cbr\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e: Semi-conducting cross-linked copolymer; A conductor separator is used for cable size larger than or equal to 500 Kcmil\u003cbr\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: 115 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% insulation level\u003cbr\u003e\u003cstrong\u003eInsulation Shield\u003c\/strong\u003e: Strippable semi-conducting cross-linked copolymer\u003cbr\u003e\u003cstrong\u003eCopper Tape Shield\u003c\/strong\u003e: Helically wrapped 5 mil copper tape with 25% overlap\u003cbr\u003e\u003cstrong\u003eFiller\u003c\/strong\u003e: Interstices filled with non-hydroscoping\/non-wicking fillers\u003cbr\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e Class B compressed stranded bare copper ground per ASTM B3 and ASTM B8\u003cbr\u003e\u003cstrong\u003eBinder\u003c\/strong\u003e: Polypropylene tape\u003cbr\u003e\u003cstrong\u003eInner Jacket\u003c\/strong\u003e: PVC inner jacket\u003cbr\u003e\u003cstrong\u003eArmour\u003c\/strong\u003e: Aluminum Interlocked Armour (AIA)\u003cbr\u003e\u003cstrong\u003eOverall Jacket\u003c\/strong\u003e: Orange Polyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e ASTM B801 Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy\u003cbr\u003e ASTM B836 Compact Rounded Stranded Aluminum Conductors\u003cbr\u003e CSA C22.2 No. 174 Cables in Hazardous Locations\u003cbr\u003e CSA C22.2 No. 2556 \u0026amp; No. 0.3 Wire and Cable Test Methods\u003cbr\u003e CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV\u003cbr\u003e CSA C68.3 Shielded \u0026amp; Concentric Neutral Power Cable - 5 to 46 kV\u003cbr\u003e CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating\u003cbr\u003e CSA HL - for Hazardous Locations rating\u003cbr\u003e CSA SUN RES - for Sunlight Resistant rating\u003cbr\u003e ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable\u003cbr\u003e ICEA T-29-520 Flame Test (210,000 BTU\/Hr)\u003cbr\u003e IEEE 383 Flame Test (70,000 btu)\u003cbr\u003e IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003cbr\u003e FT1 Flame Test (1,706 BTU\/Hr nominal - Vertical Wire Flame Test)\u003cbr\u003e AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through  46KV (Qualification Test Requirements)\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSPECIFICATIONS:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor size: \u003c\/strong\u003e250AWG\u003cbr\u003e\u003cstrong\u003eStrand: \u003c\/strong\u003e37\u003cbr\u003e\u003cstrong\u003eDiameter Over Conductor: \u003c\/strong\u003e0.520inch\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation: \u003c\/strong\u003e0.796inch\u003cbr\u003e\u003cstrong\u003eInsulation Thickness: \u003c\/strong\u003e115mil\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation Shield: \u003c\/strong\u003e0.856inch\u003cbr\u003e\u003cstrong\u003eGround \u003c\/strong\u003e\u003cstrong\u003eSize:  \u003c\/strong\u003e4AWG\u003cbr\u003e\u003cstrong\u003eInner Jacket Thickness:\u003c\/strong\u003e 110mil\u003cbr\u003e\u003cstrong\u003eDiameter. Over Armour: \u003c\/strong\u003e2.468inch\u003cbr\u003e\u003cstrong\u003eOverall Jacket Thickness: \u003c\/strong\u003e75mil\u003cbr\u003e\u003cstrong\u003eApprox.OD: \u003c\/strong\u003e2.618inch\u003cbr\u003e\u003cstrong\u003eApprox. \u003c\/strong\u003e\u003cstrong\u003eWeight(lb\/1000ft): \u003c\/strong\u003e2886\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":64645030707569,"sku":"NNC7891","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_16_1f748ac1-19f1-4f85-94c2-51d8cc5cb459.png?v=1790055325"},{"product_id":"350-mcm-3c-hvteck-aluminum-115-mil-nlepr-ts-aia-5kv-133-il-orange-pvc-jacket-csa","title":"350 MCM 3C HVTECK Aluminum 115 mil NLEPR TS AIA 5kV 133% IL Orange PVC Jacket CSA","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC26162_1.pdf?v=1790060425\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e350 MCM 3C HVTECK Aluminum 115 mil NLEPR TS AIA 5kV 133% IL Orange PVC Jacket CSA\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplication:\u003c\/h3\u003e\n\u003cp\u003eThe  5kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications. Rated FT4, -40°C, Hazardous Locations (HL). These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lbs \/FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids and are flame retardant. 3 Conductor, 115 Mils No Lead Ethylene Propylene Rubber (NL-EPR), 133% Insulation Level, Tape Shield, Polyvinyl Chloride (PVC) Inner Jacket, Aluminum Interlocked Armour (AIA), Polyvinyl Chloride (PVC) Jacket.\u003c\/p\u003e\n\u003ch3\u003eAlso known as :\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e350 MNM 3C 5kV HVTECK Cable, 350 MNM 3C \u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e5kV HVTECK Armoured Cable, 350 MNM 3C 5kV CSA Armoured Cable, 350 MNM 3C 5kV Medium Voltage Cable, 350 MNM 3C 5kV MV Power Cable, 350 MNM 3C 5kV Shielded Power Cable, 350 MNM 3C 5kV 3\/C Aluminum Cable, 350 MNM 3C 3\/C Aluminum Medium Voltage Cable, 350-3C Aluminum Armoured MV Cable, 350-3C Aluminum Interlocked Armour Cable, 350-3C AIA Armoured Cable, 350-3C 5kV AIA Cable, 350-3C NL-EPR Insulated Cable, 350-3C 115 mil EPR Cable, 350-3C 133% Insulation Level Cable, 350-3C Copper Tape Shielded Cable, 350-3C PVC Jacketed Armoured Cable, 350-3C Orange PVC Jacket Cable, 350-3C CSA HVTECK Cable.\u003c\/p\u003e\n\u003ch3\u003eConstruction:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Class B compact stranded 8000 Series aluminum per ASTM B800 and ASTM B836\u003cbr\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e: Semi-conducting cross-linked copolymer; A conductor separator is used for cable size larger than or equal to 500 Kcmil\u003cbr\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: 115 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% insulation level\u003cbr\u003e\u003cstrong\u003eInsulation Shield\u003c\/strong\u003e: Strippable semi-conducting cross-linked copolymer\u003cbr\u003e\u003cstrong\u003eCopper Tape Shield\u003c\/strong\u003e: Helically wrapped 5 mil copper tape with 25% overlap\u003cbr\u003e\u003cstrong\u003eFiller\u003c\/strong\u003e: Interstices filled with non-hydroscoping\/non-wicking fillers\u003cbr\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e Class B compressed stranded bare copper ground per ASTM B3 and ASTM B8\u003cbr\u003e\u003cstrong\u003eBinder\u003c\/strong\u003e: Polypropylene tape\u003cbr\u003e\u003cstrong\u003eInner Jacket\u003c\/strong\u003e: PVC inner jacket\u003cbr\u003e\u003cstrong\u003eArmour\u003c\/strong\u003e: Aluminum Interlocked Armour (AIA)\u003cbr\u003e\u003cstrong\u003eOverall Jacket\u003c\/strong\u003e: Orange Polyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e ASTM B801 Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy\u003cbr\u003e ASTM B836 Compact Rounded Stranded Aluminum Conductors\u003cbr\u003e CSA C22.2 No. 174 Cables in Hazardous Locations\u003cbr\u003e CSA C22.2 No. 2556 \u0026amp; No. 0.3 Wire and Cable Test Methods\u003cbr\u003e CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV\u003cbr\u003e CSA C68.3 Shielded \u0026amp; Concentric Neutral Power Cable - 5 to 46 kV\u003cbr\u003e CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating\u003cbr\u003e CSA HL - for Hazardous Locations rating\u003cbr\u003e CSA SUN RES - for Sunlight Resistant rating\u003cbr\u003e ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable\u003cbr\u003e ICEA T-29-520 Flame Test (210,000 BTU\/Hr)\u003cbr\u003e IEEE 383 Flame Test (70,000 btu)\u003cbr\u003e IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003cbr\u003e FT1 Flame Test (1,706 BTU\/Hr nominal - Vertical Wire Flame Test)\u003cbr\u003e AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through  46KV (Qualification Test Requirements)\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor size:\u003c\/strong\u003e 350\u003cstrong\u003e \u003c\/strong\u003eAWG\u003cbr\u003e\u003cstrong\u003eStrand: \u003c\/strong\u003e37\u003cbr\u003e\u003cstrong\u003eDiameter Over Conductor: \u003c\/strong\u003e0.615inch\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation:\u003c\/strong\u003e 0.891inch\u003cbr\u003e\u003cstrong\u003eInsulation Thickness: \u003c\/strong\u003e115mil\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation Shield: \u003c\/strong\u003e0.951inch\u003cbr\u003e\u003cstrong\u003eGround \u003c\/strong\u003e\u003cstrong\u003eSize:  \u003c\/strong\u003e4AWG\u003cbr\u003e\u003cstrong\u003eInner Jacket Thickness:\u003c\/strong\u003e 110mil\u003cbr\u003e\u003cstrong\u003eDiameter. Over Armour: \u003c\/strong\u003e2.673inch\u003cbr\u003e\u003cstrong\u003eOverall Jacket Thickness: \u003c\/strong\u003e75mil\u003cbr\u003e\u003cstrong\u003eApprox.OD: \u003c\/strong\u003e2.823inch\u003cbr\u003e\u003cstrong\u003eApprox. \u003c\/strong\u003e\u003cstrong\u003eWeight(lb\/1000ft):\u003c\/strong\u003e 3419\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":64645091918193,"sku":"NNC1104","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_16_1f748ac1-19f1-4f85-94c2-51d8cc5cb459.png?v=1790055325"},{"product_id":"500-mcm-3c-hvteck-aluminum-115-mil-nlepr-ts-aia-5kv-133-il-orange-pvc-jacket-csa","title":"500 MCM 3C HVTECK Aluminum 115 mil NLEPR TS AIA 5kV 133% IL Orange PVC Jacket CSA","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC26162_1.pdf?v=1790060425\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e500 MCM 3C HVTECK Aluminum 115 mil NLEPR TS AIA 5kV 133% IL Orange PVC Jacket CSA\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplication:\u003c\/h3\u003e\n\u003cp\u003eThe  5kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications. Rated FT4, -40°C, Hazardous Locations (HL). These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lbs \/FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids and are flame retardant. 3 Conductor, 115 Mils No Lead Ethylene Propylene Rubber (NL-EPR), 133% Insulation Level, Tape Shield, Polyvinyl Chloride (PVC) Inner Jacket, Aluminum Interlocked Armour (AIA), Polyvinyl Chloride (PVC) Jacket.\u003c\/p\u003e\n\u003ch3\u003eAlso known as :\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e500MNM 3C 5kV HVTECK Cable, 500MNM 3C \u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e5kV HVTECK Armoured Cable, 500 MNM 3C 5kV CSA Armoured Cable, 500MNM 3C 5kV Medium Voltage Cable, 500 MNM 3C 5kV MV Power Cable, 500 MNM 3C 5kV Shielded Power Cable, 500 MNM 3C 5kV 3\/C Aluminum Cable, 500 MNM 3C 3\/C Aluminum Medium Voltage Cable, 500-3C Aluminum Armoured MV Cable, 500-3C Aluminum Interlocked Armour Cable, 500-3C AIA Armoured Cable, 500-3C 5kV AIA Cable, 500-3C NL-EPR Insulated Cable, 500-3C 115 mil EPR Cable, 500-3C 133% Insulation Level Cable, 500-3C Copper Tape Shielded Cable, 500-3C PVC Jacketed Armoured Cable, 500-3C Orange PVC Jacket Cable, 500-3C CSA HVTECK Cable.\u003c\/p\u003e\n\u003ch3\u003eConstruction:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Class B compact stranded 8000 Series aluminum per ASTM B800 and ASTM B836\u003cbr\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e: Semi-conducting cross-linked copolymer; A conductor separator is used for cable size larger than or equal to 500 Kcmil\u003cbr\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: 115 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% insulation level\u003cbr\u003e\u003cstrong\u003eInsulation Shield\u003c\/strong\u003e: Strippable semi-conducting cross-linked copolymer\u003cbr\u003e\u003cstrong\u003eCopper Tape Shield\u003c\/strong\u003e: Helically wrapped 5 mil copper tape with 25% overlap\u003cbr\u003e\u003cstrong\u003eFiller\u003c\/strong\u003e: Interstices filled with non-hydroscoping\/non-wicking fillers\u003cbr\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e Class B compressed stranded bare copper ground per ASTM B3 and ASTM B8\u003cbr\u003e\u003cstrong\u003eBinder\u003c\/strong\u003e: Polypropylene tape\u003cbr\u003e\u003cstrong\u003eInner Jacket\u003c\/strong\u003e: PVC inner jacket\u003cbr\u003e\u003cstrong\u003eArmour\u003c\/strong\u003e: Aluminum Interlocked Armour (AIA)\u003cbr\u003e\u003cstrong\u003eOverall Jacket\u003c\/strong\u003e: Orange Polyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e ASTM B801 Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy\u003cbr\u003e ASTM B836 Compact Rounded Stranded Aluminum Conductors\u003cbr\u003e CSA C22.2 No. 174 Cables in Hazardous Locations\u003cbr\u003e CSA C22.2 No. 2556 \u0026amp; No. 0.3 Wire and Cable Test Methods\u003cbr\u003e CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV\u003cbr\u003e CSA C68.3 Shielded \u0026amp; Concentric Neutral Power Cable - 5 to 46 kV\u003cbr\u003e CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating\u003cbr\u003e CSA HL - for Hazardous Locations rating\u003cbr\u003e CSA SUN RES - for Sunlight Resistant rating\u003cbr\u003e ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable\u003cbr\u003e ICEA T-29-520 Flame Test (210,000 BTU\/Hr)\u003cbr\u003e IEEE 383 Flame Test (70,000 btu)\u003cbr\u003e IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003cbr\u003e FT1 Flame Test (1,706 BTU\/Hr nominal - Vertical Wire Flame Test)\u003cbr\u003e AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through  46KV (Qualification Test Requirements)\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor size:\u003c\/strong\u003e 500\u003cstrong\u003e \u003c\/strong\u003eAWG\u003cbr\u003e\u003cstrong\u003eStrand: \u003c\/strong\u003e37\u003cbr\u003e\u003cstrong\u003eDiameter Over Conductor: \u003c\/strong\u003e0.735inch\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation:\u003c\/strong\u003e 1.011inch\u003cbr\u003e\u003cstrong\u003eInsulation Thickness: \u003c\/strong\u003e115mil\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation Shield: \u003c\/strong\u003e1.071inch\u003cbr\u003e\u003cstrong\u003eGround \u003c\/strong\u003e\u003cstrong\u003eSize:  \u003c\/strong\u003e3AWG\u003cbr\u003e\u003cstrong\u003eInner Jacket Thickness:\u003c\/strong\u003e 110mil\u003cbr\u003e\u003cstrong\u003eDiameter. Over Armour: \u003c\/strong\u003e2.933inch\u003cbr\u003e\u003cstrong\u003eOverall Jacket Thickness: \u003c\/strong\u003e75mil\u003cbr\u003e\u003cstrong\u003eApprox.OD: \u003c\/strong\u003e3.083inch\u003cbr\u003e\u003cstrong\u003eApprox. \u003c\/strong\u003e\u003cstrong\u003eWeight(lb\/1000ft):\u003c\/strong\u003e 4185\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":64645236556145,"sku":"NNC0631","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_16_1f748ac1-19f1-4f85-94c2-51d8cc5cb459.png?v=1790055325"},{"product_id":"750-mcm-3c-61-strand-hvteck-aluminum-115-mil-nlepr-ts-aia-5kv-133-il-orange-pvc-jacket-csa","title":"750 MCM 3C 61 Strand HVTECK Aluminum 115 mil NLEPR TS AIA 5kV 133% IL Orange PVC Jacket CSA","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC26162_1.pdf?v=1790060425\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e750 MCM 3C 61 Strand HVTECK Aluminum 115 mil NLEPR TS AIA 5kV 133% IL Orange PVC Jacket CSA\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplication:\u003c\/h3\u003e\n\u003cp\u003eThe  5kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications. Rated FT4, -40°C, Hazardous Locations (HL). These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lbs \/FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids and are flame retardant. 3 Conductor, 115 Mils No Lead Ethylene Propylene Rubber (NL-EPR), 133% Insulation Level, Tape Shield, Polyvinyl Chloride (PVC) Inner Jacket, Aluminum Interlocked Armour (AIA), Polyvinyl Chloride (PVC) Jacket.\u003c\/p\u003e\n\u003ch3\u003eAlso known as :\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e750MNM 3C 5kV HVTECK Cable, 750 MNM 3C \u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e5kV HVTECK Armoured Cable, 750 MNM 3C 5kV CSA Armoured Cable, 750 MNM 3C 5kV Medium Voltage Cable, 750 MNM 3C 5kV MV Power Cable, 750 MNM 3C 5kV Shielded Power Cable, 750 MNM 3C 5kV 3\/C Aluminum Cable, 750 MNM 3C 3\/C Aluminum Medium Voltage Cable, 750-3C Aluminum Armoured MV Cable, 750-3C Aluminum Interlocked Armour Cable, 750-3C AIA Armoured Cable, 750-3C 5kV AIA Cable, 750-3C NL-EPR Insulated Cable, 750-3C 115 mil EPR Cable, 750-3C 133% Insulation Level Cable, 750-3C Copper Tape Shielded Cable, 750-3C PVC Jacketed Armoured Cable, 750-3C Orange PVC Jacket Cable, 750-3C CSA HVTECK Cable.\u003c\/p\u003e\n\u003ch3\u003eConstruction:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Class B compact stranded 8000 Series aluminum per ASTM B800 and ASTM B836\u003cbr\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e: Semi-conducting cross-linked copolymer; A conductor separator is used for cable size larger than or equal to 500 Kcmil\u003cbr\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: 115 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% insulation level\u003cbr\u003e\u003cstrong\u003eInsulation Shield\u003c\/strong\u003e: Strippable semi-conducting cross-linked copolymer\u003cbr\u003e\u003cstrong\u003eCopper Tape Shield\u003c\/strong\u003e: Helically wrapped 5 mil copper tape with 25% overlap\u003cbr\u003e\u003cstrong\u003eFiller\u003c\/strong\u003e: Interstices filled with non-hydroscoping\/non-wicking fillers\u003cbr\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e Class B compressed stranded bare copper ground per ASTM B3 and ASTM B8\u003cbr\u003e\u003cstrong\u003eBinder\u003c\/strong\u003e: Polypropylene tape\u003cbr\u003e\u003cstrong\u003eInner Jacket\u003c\/strong\u003e: PVC inner jacket\u003cbr\u003e\u003cstrong\u003eArmour\u003c\/strong\u003e: Aluminum Interlocked Armour (AIA)\u003cbr\u003e\u003cstrong\u003eOverall Jacket\u003c\/strong\u003e: Orange Polyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e ASTM B801 Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy\u003cbr\u003e ASTM B836 Compact Rounded Stranded Aluminum Conductors\u003cbr\u003e CSA C22.2 No. 174 Cables in Hazardous Locations\u003cbr\u003e CSA C22.2 No. 2556 \u0026amp; No. 0.3 Wire and Cable Test Methods\u003cbr\u003e CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV\u003cbr\u003e CSA C68.3 Shielded \u0026amp; Concentric Neutral Power Cable - 5 to 46 kV\u003cbr\u003e CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating\u003cbr\u003e CSA HL - for Hazardous Locations rating\u003cbr\u003e CSA SUN RES - for Sunlight Resistant rating\u003cbr\u003e ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable\u003cbr\u003e ICEA T-29-520 Flame Test (210,000 BTU\/Hr)\u003cbr\u003e IEEE 383 Flame Test (70,000 btu)\u003cbr\u003e IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003cbr\u003e FT1 Flame Test (1,706 BTU\/Hr nominal - Vertical Wire Flame Test)\u003cbr\u003e AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through  46KV (Qualification Test Requirements)\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor size:\u003c\/strong\u003e 750AWG\u003cbr\u003e\u003cstrong\u003eStrand: \u003c\/strong\u003e61\u003cbr\u003e\u003cstrong\u003eDiameter Over Conductor: \u003c\/strong\u003e0.908inch\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation:\u003c\/strong\u003e 1.194inch\u003cbr\u003e\u003cstrong\u003eInsulation Thickness: \u003c\/strong\u003e115mil\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation Shield: \u003c\/strong\u003e1.254inch\u003cbr\u003e\u003cstrong\u003eGround \u003c\/strong\u003e\u003cstrong\u003eSize:  \u003c\/strong\u003e2AWG\u003cbr\u003e\u003cstrong\u003eInner Jacket Thickness:\u003c\/strong\u003e 125mil\u003cbr\u003e\u003cstrong\u003eDiameter. Over Armour:\u003c\/strong\u003e 3.358inch\u003cbr\u003e\u003cstrong\u003eOverall Jacket Thickness: \u003c\/strong\u003e85mil\u003cbr\u003e\u003cstrong\u003eApprox.OD: \u003c\/strong\u003e 3.528inch\u003cbr\u003e\u003cstrong\u003eApprox. \u003c\/strong\u003e\u003cstrong\u003eWeight(lb\/1000ft): \u003c\/strong\u003e5606\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":64645267030385,"sku":"NNC7452","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_16_1f748ac1-19f1-4f85-94c2-51d8cc5cb459.png?v=1790055325"},{"product_id":"750-mcm-3c-58-strand-hvteck-aluminum-115-mil-nlepr-ts-aia-5kv-133-il-orange-pvc-jacket-csa","title":"750 MCM 3C 58 Strand HVTECK Aluminum 115 mil NLEPR TS AIA 5kV 133% IL Orange PVC Jacket CSA","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC26162_1.pdf?v=1790060425\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e750 MCM 3C 58 Strand HVTECK Aluminum 115 mil NLEPR TS AIA 5kV 133% IL Orange PVC Jacket CSA\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplication:\u003c\/h3\u003e\n\u003cp\u003eThe  5kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications. Rated FT4, -40°C, Hazardous Locations (HL). These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lbs \/FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids and are flame retardant. 3 Conductor, 115 Mils No Lead Ethylene Propylene Rubber (NL-EPR), 133% Insulation Level, Tape Shield, Polyvinyl Chloride (PVC) Inner Jacket, Aluminum Interlocked Armour (AIA), Polyvinyl Chloride (PVC) Jacket.\u003c\/p\u003e\n\u003ch3\u003eAlso known as :\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e750 MNM 3C 5kV HVTECK Cable, 750 MNM 3C \u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e5kV HVTECK Armoured Cable, 750 MNM 3C 5kV CSA Armoured Cable, 750 MNM 3C 5kV Medium Voltage Cable, 750 MNM 3C 5kV MV Power Cable, 750 MNM 3C 5kV Shielded Power Cable, 750 MNM 3C 5kV 3\/C Aluminum Cable, 750 MNM 3C 3\/C Aluminum Medium Voltage Cable, 750-3C Aluminum Armoured MV Cable, 750-3C Aluminum Interlocked Armour Cable, 750-3C AIA Armoured Cable, 750-3C 5kV AIA Cable, 750-3C NL-EPR Insulated Cable, 750-3C 115 mil EPR Cable, 750-3C 133% Insulation Level Cable, 750-3C Copper Tape Shielded Cable, 750-3C PVC Jacketed Armoured Cable, 750-3C Orange PVC Jacket Cable, 750-3C CSA HVTECK Cable.\u003c\/p\u003e\n\u003ch3\u003eConstruction:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Class B compact stranded 8000 Series aluminum per ASTM B800 and ASTM B836\u003cbr\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e: Semi-conducting cross-linked copolymer; A conductor separator is used for cable size larger than or equal to 500 Kcmil\u003cbr\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: 115 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% insulation level\u003cbr\u003e\u003cstrong\u003eInsulation Shield\u003c\/strong\u003e: Strippable semi-conducting cross-linked copolymer\u003cbr\u003e\u003cstrong\u003eCopper Tape Shield\u003c\/strong\u003e: Helically wrapped 5 mil copper tape with 25% overlap\u003cbr\u003e\u003cstrong\u003eFiller\u003c\/strong\u003e: Interstices filled with non-hydroscoping\/non-wicking fillers\u003cbr\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e Class B compressed stranded bare copper ground per ASTM B3 and ASTM B8\u003cbr\u003e\u003cstrong\u003eBinder\u003c\/strong\u003e: Polypropylene tape\u003cbr\u003e\u003cstrong\u003eInner Jacket\u003c\/strong\u003e: PVC inner jacket\u003cbr\u003e\u003cstrong\u003eArmour\u003c\/strong\u003e: Aluminum Interlocked Armour (AIA)\u003cbr\u003e\u003cstrong\u003eOverall Jacket\u003c\/strong\u003e: Orange Polyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e ASTM B801 Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy\u003cbr\u003e ASTM B836 Compact Rounded Stranded Aluminum Conductors\u003cbr\u003e CSA C22.2 No. 174 Cables in Hazardous Locations\u003cbr\u003e CSA C22.2 No. 2556 \u0026amp; No. 0.3 Wire and Cable Test Methods\u003cbr\u003e CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV\u003cbr\u003e CSA C68.3 Shielded \u0026amp; Concentric Neutral Power Cable - 5 to 46 kV\u003cbr\u003e CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating\u003cbr\u003e CSA HL - for Hazardous Locations rating\u003cbr\u003e CSA SUN RES - for Sunlight Resistant rating\u003cbr\u003e ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable\u003cbr\u003e ICEA T-29-520 Flame Test (210,000 BTU\/Hr)\u003cbr\u003e IEEE 383 Flame Test (70,000 btu)\u003cbr\u003e IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003cbr\u003e FT1 Flame Test (1,706 BTU\/Hr nominal - Vertical Wire Flame Test)\u003cbr\u003e AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through  46KV (Qualification Test Requirements)\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor size:\u003c\/strong\u003e 750AWG\u003cbr\u003e\u003cstrong\u003eStrand: \u003c\/strong\u003e58\u003cbr\u003e\u003cstrong\u003eDiameter Over Conductor: \u003c\/strong\u003e0.908inch\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation:\u003c\/strong\u003e 1.206inch\u003cbr\u003e\u003cstrong\u003eInsulation Thickness: \u003c\/strong\u003e115mil\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation Shield: \u003c\/strong\u003e1.266inch\u003cbr\u003e\u003cstrong\u003eGround \u003c\/strong\u003e\u003cstrong\u003eSize:  \u003c\/strong\u003e2AWG\u003cbr\u003e\u003cstrong\u003eInner Jacket Thickness:\u003c\/strong\u003e 125mil\u003cbr\u003e\u003cstrong\u003eDiameter. Over Armour:\u003c\/strong\u003e 3.398inch\u003cbr\u003e\u003cstrong\u003eOverall Jacket Thickness: \u003c\/strong\u003e85mil\u003cbr\u003e\u003cstrong\u003eApprox.OD: \u003c\/strong\u003e3.528inch\u003cbr\u003e\u003cstrong\u003eApprox. \u003c\/strong\u003e\u003cstrong\u003eWeight(lb\/1000ft): \u003c\/strong\u003e5839\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable style=\"width: 340px; height: 79.1904px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"width: 325.114px; height: 35.5966px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 160.597px;\"\u003e\u003cstrong\u003eSouthwire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 164.517px;\"\u003e\u003cspan\u003e137966\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":64645286166897,"sku":"NNC137966","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_16_1f748ac1-19f1-4f85-94c2-51d8cc5cb459.png?v=1790055325"},{"product_id":"1000-mcm-3c-hvteck-aluminum-115-mil-nlepr-ts-aia-5kv-133-il-orange-pvc-jacket-csa","title":"1000 MCM 3C HVTECK Aluminum 115 mil NLEPR TS AIA 5kV 133% IL Orange PVC Jacket CSA","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SOUTHWIRE_SPEC26162_1.pdf?v=1790060425\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e1000 MCM 3C HVTECK Aluminum 115 mil NLEPR TS AIA 5kV 133% IL Orange PVC Jacket CSA\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplication:\u003c\/h3\u003e\n\u003cp\u003eThe  5kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications. Rated FT4, -40°C, Hazardous Locations (HL). These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lbs \/FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids and are flame retardant. 3 Conductor, 115 Mils No Lead Ethylene Propylene Rubber (NL-EPR), 133% Insulation Level, Tape Shield, Polyvinyl Chloride (PVC) Inner Jacket, Aluminum Interlocked Armour (AIA), Polyvinyl Chloride (PVC) Jacket.\u003c\/p\u003e\n\u003ch3\u003eAlso known as :\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e1000 MNM 3C 5kV HVTECK Cable, 1000 MNM 3C \u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e5kV HVTECK Armoured Cable, 1000 MNM 3C 5kV CSA Armoured Cable, 1000 MNM 3C 5kV Medium Voltage Cable, 1000 MNM 3C 5kV MV Power Cable, 1000 MNM 3C 5kV Shielded Power Cable, 1000 MNM 3C 5kV 3\/C Aluminum Cable, 1000 MNM 3C 3\/C Aluminum Medium Voltage Cable, 1000-3C Aluminum Armoured MV Cable, 1000-3C Aluminum Interlocked Armour Cable, 1000-3C AIA Armoured Cable, 1000-3C 5kV AIA Cable, 1000-3C NL-EPR Insulated Cable, 1000-3C 115 mil EPR Cable, 1000-3C 133% Insulation Level Cable, 1000-3C Copper Tape Shielded Cable, 1000-3C PVC Jacketed Armoured Cable, 1000-3C Orange PVC Jacket Cable, 1000-3C CSA HVTECK Cable.\u003c\/p\u003e\n\u003ch3\u003eConstruction:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Class B compact stranded 8000 Series aluminum per ASTM B800 and ASTM B836\u003cbr\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e: Semi-conducting cross-linked copolymer; A conductor separator is used for cable size larger than or equal to 500 Kcmil\u003cbr\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: 115 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% insulation level\u003cbr\u003e\u003cstrong\u003eInsulation Shield\u003c\/strong\u003e: Strippable semi-conducting cross-linked copolymer\u003cbr\u003e\u003cstrong\u003eCopper Tape Shield\u003c\/strong\u003e: Helically wrapped 5 mil copper tape with 25% overlap\u003cbr\u003e\u003cstrong\u003eFiller\u003c\/strong\u003e: Interstices filled with non-hydroscoping\/non-wicking fillers\u003cbr\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e Class B compressed stranded bare copper ground per ASTM B3 and ASTM B8\u003cbr\u003e\u003cstrong\u003eBinder\u003c\/strong\u003e: Polypropylene tape\u003cbr\u003e\u003cstrong\u003eInner Jacket\u003c\/strong\u003e: PVC inner jacket\u003cbr\u003e\u003cstrong\u003eArmour\u003c\/strong\u003e: Aluminum Interlocked Armour (AIA)\u003cbr\u003e\u003cstrong\u003eOverall Jacket\u003c\/strong\u003e: Orange Polyvinyl Chloride (PVC) Jacket\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cp\u003e ASTM B801 Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy\u003cbr\u003e ASTM B836 Compact Rounded Stranded Aluminum Conductors\u003cbr\u003e CSA C22.2 No. 174 Cables in Hazardous Locations\u003cbr\u003e CSA C22.2 No. 2556 \u0026amp; No. 0.3 Wire and Cable Test Methods\u003cbr\u003e CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV\u003cbr\u003e CSA C68.3 Shielded \u0026amp; Concentric Neutral Power Cable - 5 to 46 kV\u003cbr\u003e CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating\u003cbr\u003e CSA HL - for Hazardous Locations rating\u003cbr\u003e CSA SUN RES - for Sunlight Resistant rating\u003cbr\u003e ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable\u003cbr\u003e ICEA T-29-520 Flame Test (210,000 BTU\/Hr)\u003cbr\u003e IEEE 383 Flame Test (70,000 btu)\u003cbr\u003e IEEE 1202 FT4 Flame Test (70,000) BTU\/hr Vertical Tray Test\u003cbr\u003e FT1 Flame Test (1,706 BTU\/Hr nominal - Vertical Wire Flame Test)\u003cbr\u003e AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through  46KV (Qualification Test Requirements)\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductor size:\u003c\/strong\u003e 1000AWG\u003cbr\u003e\u003cstrong\u003eStrand: \u003c\/strong\u003e61\u003cbr\u003e\u003cstrong\u003eDiameter Over Conductor: \u003c\/strong\u003e1.060inch\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation:\u003c\/strong\u003e 1.346inch\u003cbr\u003e\u003cstrong\u003eInsulation Thickness: \u003c\/strong\u003e115mil\u003cbr\u003e\u003cstrong\u003eDiameter Over Insulation Shield: \u003c\/strong\u003e1.406inch\u003cbr\u003e\u003cstrong\u003eGround \u003c\/strong\u003e\u003cstrong\u003eSize:  \u003c\/strong\u003e2AWG\u003cbr\u003e\u003cstrong\u003eInner Jacket Thickness:\u003c\/strong\u003e 125mil\u003cbr\u003e\u003cstrong\u003eDiameter. Over Armour: \u003c\/strong\u003e3.686nch\u003cbr\u003e\u003cstrong\u003eOverall Jacket Thickness: \u003c\/strong\u003e85mil\u003cbr\u003e\u003cstrong\u003eApprox.OD:  \u003c\/strong\u003e3.856inch\u003cbr\u003e\u003cstrong\u003eApprox. \u003c\/strong\u003e\u003cstrong\u003eWeight(lb\/1000ft):\u003c\/strong\u003e 6770\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":64645545754993,"sku":"NNC7894","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_16_1f748ac1-19f1-4f85-94c2-51d8cc5cb459.png?v=1790055325"}],"url":"https:\/\/nassaunationalcable.com\/collections\/hvteck-aluminum-3-c-115-mil-nlepr-ts-aia-5kv-133-il-orange-pvc-jacket-csa.oembed","provider":"NassauNationalCable","version":"1.0","type":"link"}