{"title":"Aluminum XLP USE-2 RHH\/RHW-2 Direct Burial Building Wire","description":"\u003cstyle\u003e\u003c!--\ncategory-banner IMG {\n    display: block;\n    width: 100%;\n    max-height: 250px;\n    object-fit: cover;\n    position: relative;\n}\n Category-description h4 {\n    color: #000;\n    letter-spacing: 0;\n    font-weight: bold;\n    margin-bottom: 15px;\n}\n  category-description {\n    font-size: 16px;clear: both;\n}\n  category-description li, .category-description p {\n    color: #000;    \n}\n--\u003e\u003c\/style\u003e\n\u003cdiv class=\"category-banner\"\u003e\n\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/ALUMINUM_XHHW_SER_SEU_RHH_RHW-2_XLP_USE-2.png?v=1667576240\"\u003e\n\u003cdiv id=\"category-description\"\u003e\n\u003c!-- split --\u003e\n\u003ch4\u003eAbout the Aluminum Cables\u003c\/h4\u003e\n  \u003cp\u003e\n    Aluminum cables have a large impact in the current developing world.\n    \u003cbr\u003e\n    They have been used over the years to enhance technology. Thanks to the aluminum cable various machines operations\n    are enhanced. There various versions of the aluminum cable, the most common ones are Home feeder cable, \u003ca href=\"\/collections\/aluminum-xhhw-ser-seu-rhh-rhw-2-xlp-use-2\/products\/xhhw-2\"\u003eXHHW\u003c\/a\u003e, \u003ca href=\"\/collections\/aluminum-xhhw-ser-seu-rhh-rhw-2-xlp-use-2\/products\/ser\"\u003eSER\u003c\/a\u003e, \u003ca href=\"\/collections\/aluminum-xhhw-ser-seu-rhh-rhw-2-xlp-use-2\/products\/seu\"\u003eSEU\u003c\/a\u003e, \u003ca href=\"\/collections\/aluminum-xhhw-ser-seu-rhh-rhw-2-xlp-use-2\/products\/aluminum-rhh-rhw-2-use-2-90-c-xlpe-insulation-600v\"\u003eRHH\u003c\/a\u003e, \u003ca href=\"\/collections\/aluminum-xhhw-ser-seu-rhh-rhw-2-xlp-use-2\/products\/aluminum-rhh-rhw-2-use-2-90-c-xlpe-insulation-600v\"\u003eRHW-2\u003c\/a\u003e and \u003ca href=\"\/collections\/aluminum-xhhw-ser-seu-rhh-rhw-2-xlp-use-2\/products\/aluminum-rhh-rhw-2-use-2-90-c-xlpe-insulation-600v\"\u003eUSE-2\u003c\/a\u003e. Aluminum cables have high reliability and less prone to failure that’s why they are the most sort after cables.\n    Power transmission require robust cables which can withstand any type of punishing environments and high voltage\n    ratings this is where the aluminum cables come in handy.\n  \u003c\/p\u003e\n  \u003cp\u003e\n    Aluminum cables have a wide range of applications in industries, power transmission and technology in general. In\n    this post, we will share with you some of the specifications of the aluminum cable and why it is the most preferred\n    cable for your power transmission applications.\u003cbr\u003e    \n  \u003c\/p\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eBenefits of aluminum cables:\u003c\/strong\u003e\u003cbr\u003e\n  \u003col\u003e\n    \u003cli\u003e\n      Aluminum is very durable since it can withstand harsh environmental conditions, therefore can last longer compared to other power transmission cables\n    \u003c\/li\u003e\n    \u003cli\u003eAluminum is very easy to work with due to its flexibility\u003c\/li\u003e\n    \u003cli\u003eAluminum has excellent electrical properties and can transmit current with ease\u003c\/li\u003e\n    \u003cli\u003eAluminum is easily recycled and can be put to other use once worn out\u003c\/li\u003e\n    \u003cli\u003eAluminum is robust and can withstand external forces which may cause damage to the conductor\u003c\/li\u003e\n    \u003cli\u003eAluminum cables are cheap compared to copper cables\u003c\/li\u003e\n    \u003cli\u003eThey are lighter in weight compared to other metals\u003c\/li\u003e\n    \u003cli\u003e\n      They have the same conductivity as copper when compared in terms of loading\n    \u003c\/li\u003e\n  \u003c\/ol\u003e\n  \u003c\/div\u003e\n  \n    \u003cp\u003e\u003cstrong\u003eChoose the appropriate aluminum cable:\u003c\/strong\u003e\u003cbr\u003e\n      When choosing the appropriate aluminum cable that matches your specific needs, you should put many factors in to\n      considerations.\u003c\/p\u003e\n    \u003cp\u003e\n      First and foremost is the cable size. Cables are normally categorized in to sizes. The aluminum\n      cable is basically graded in to the AWG sizes. A standard used in North America for naming wire gauges. It is\n      advisable to select the appropriate aluminum cable size that matches your specific needs. Smaller cables deliver\n      small amounts of current hence you should check the voltage rating of your application before buying a cable.\u003cbr\u003e\n      Furthermore oversized cables may cost you more and still deliver the same current compared to properly sized\n      cables. Another factor to put in to consideration is whether it is a SEU cable or SER cable. Even though both are\n      Service Entrance (SE) cables but there is a slight difference. SER cables have a reinforcement tape while SEU\n      cables have an overall reinforcement all together with a neutral tape. SEU cables can be used in applications of\n      600 volts and below while SER cables are used only in applications rated at 600 volts.\n    \u003c\/p\u003e\n    \u003cp\u003e\n      There are also other various types of aluminum cables to consider before buying a roll, as mentioned earlier they\n      include type RHW-2, USE-2, RHH, XHHW among others.\n    \u003c\/p\u003e\n    \u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003cbr\u003e\n      These cables are designed to withstand harsh environments. It has a robust design and the materials used are also\n      strong. It is composed of a conductor, insulator and a jacket.\n    \u003c\/p\u003e\n    \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e\n      The aluminum cable as it name implies has a compact stranded soft drawn 8000 series aluminum conductor in\n      accordance to ASTM B-800 or B-801. The conductor is the electrode in the cable and is responsible for transmitting\n      electric current. Aluminum as hinted earlier has an amazing ionic structure which enables it to transmit current\n      easily. The stranding enhances its flexibility and enables it to carry more current. Soft drawn aluminum is also\n      easy to transport and install in constricted areas.\n    \u003c\/p\u003e\n    \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\n      It has cross-linked polyethylene (XLP) insulation. The conductors are normally cabled together with XLP insulated\n      aluminum ground or bare copper ground and covered with a reinforced binder tape. The insulation is very vital\n      since it prevents direct contact with the live wire. It also protects the conductor from damage caused by external\n      forces. XLP insulation is tough and is resistant to impact, abrasion, chemicals, acids, oils, industrial solvents\n      and changes in weather.\n    \u003c\/p\u003e\n    \u003cp\u003e\u003cstrong\u003eCable jacket:\u003c\/strong\u003e\u003cbr\u003e\n      The cable jacket used in its design is polyvinyl Chloride (PVC). The jacket protects the inner components of the\n      cable from external forces that may cause damage to it. It is also used for easy identification of the cable. PVC\n      is robust and is resistant to oil, sunlight, water, flames, acids, chemicals, radiation, impact, abrasion and\n      weather changes. On the cable jacket are sequential footage markings that help the user identify the appropriate\n      length during installation without guess work.\n    \u003c\/p\u003e\n    \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e\n      As hinted earlier in the article this cable can be used in various applications not exceeding 600 volts. These\n      include branch circuits, direct burial, panel feeders, power transmission, mobile homes, and multiple unit\n      dwellings among other various applications. It can also be used in construction sites in place of a copper\n      buildingwire.\n    \u003c\/p\u003e\n    \u003cp\u003e\n      For more information on this cable and other cable products feel free to get in touch with us and we will gladly\n      respond.\n    \u003c\/p\u003e\n    \n\u003c\/div\u003e\n\u003c\/div\u003e","products":[{"product_id":"aluminum-mobile-home-feeder-cable","title":"Aluminum Mobile Home Feeder Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/AL_MHF.pdf?v=1685791541\" width=\"\" height=\"\" type=\"application\/pdf\"\u003e [\/pdf] [short] \u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003eAluminum Mobile Home Feeder Direct Burial Cable 600V \u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eAluminum Mobile Home Feeder cable is a service entrance cable for mobile homes. The electrical cable is approved according to the National Electric Code. The maximum operating temperature of this electrical cable is 90°C in wet and dry locations. The voltage rating is 600 volts. \u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003eAluminum cable, aluminum wire, mobile home feeder cable, underground feeder cable, service entrance cable, electrical feeder cable, power feeder cable.\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eAmpacities based on National Electric Code, 2005n edition, section 310-15 \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNational Electric Code (NEC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUL 44 for types RHH \u0026amp; RHW-2 \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUL 854 for type USE-2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eASTM standards B 800, B 801 \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSunlight resistant \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRUS ACCEPTED\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConstruction\u003c\/h3\u003e\n\u003ch4\u003eConductors:\u003c\/h4\u003e\n\u003cp\u003eAluminum home feeder cable has a compact stranded soft drawn 8000 series aluminum conductor in accordance with ASTM B-800 or B-801. The conductor is the electrode in the cable and is responsible for transmitting electric current. \u003c\/p\u003e\n\u003ch4\u003eInsulation:\u003c\/h4\u003e\n\u003cp\u003eIt has cross-linked polyethylene (XLP) insulation. The conductors are normally cabled together with XLP insulated aluminum ground or bare copper ground and covered with reinforced binder tape. XLP insulation is tough and resistant to impact, abrasion, chemicals, acids, oils, industrial solvents, and changes in weather.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAluminum Mobile Home Feeder Cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt mainly functions as a service entrance cable for mobile homes. In most cases mobile homes are vulnerable to numerous factors as compared to the conventional homes hence this is the most preferred cable for any form of mobile unit and ensures maximum safety in your circuitry. It is designed to certain standard to enable it to have the uttermost reliability since it is from the home feeder cable that power distribution starts as it spreads to the entire building. It is used in applications not exceeding 600 volts. Its operating temperature is not to exceed 900C in both wet and dry locations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAluminum home feeder cable has a compact stranded soft drawn 8000 series aluminum conductor in accordance with ASTM B-800 or B-801. The conductor is the electrode in the cable and is responsible for transmitting electric current. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIt has cross-linked polyethylene (XLP) insulation. The conductors are normally cabled together with XLP insulated aluminum ground or bare copper ground and covered with reinforced binder tape. XLP insulation is tough and resistant to impact, abrasion, chemicals, acids, oils, industrial solvents, and changes in weather.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable jacket:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe cable jacket used in its design is Polyvinyl Chloride (PVC). The jacket protects the inner components of the cable from potentially damaging external forces. PVC is robust and resistant to oil, sunlight, water, flames, acids, chemicals, radiation, impact, abrasion, and weather changes. Sequential footage markings that help the user identify the appropriate length during installation are noted on the cable jacket.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial ratings and approvals:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e• National Electric Code (NEC)\u003cbr\u003e• UL 44 for types RHH \u0026amp; RHW-2 \u003cbr\u003e• UL 854 for type USE-2\u003cbr\u003e• ASTM standards B 800, B 801 \u003cbr\u003e• Sunlight resistant \u003cbr\u003e• RUS ACCEPTED\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion and Answer:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\" data-mce-style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\" data-mce-style=\"text-decoration: underline;\"\u003eFrequently Asked Questions - Aluminum Mobile Home Feeder\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\" data-mce-style=\"text-decoration: underline;\"\u003eAre there any special instructions that I have to follow while using an \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\" data-mce-style=\"text-decoration: underline;\"\u003eAluminum Mobile Home Feeder?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAluminum Mobile Home Feeders are used to bring power supply to mobile homes as stipulated in the 2011 National Electrical Code.  The voltage has to be around 600V and although it is suitable for direct burial in the ground, you must check that the maximum temperatures of the conductors do not exceed 90°C.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\" data-mce-style=\"text-decoration: underline;\"\u003eWhat are the specifications of your \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\" data-mce-style=\"text-decoration: underline;\"\u003eAluminum Mobile Home Feeder (MHF)?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOur Aluminum Mobile Home Feeders are RoHS\/REACH compliant and UL listed 44 and 854.  They are also as per Federal Specification A-A-59544 and NEC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\" data-mce-style=\"text-decoration: underline;\"\u003eHow do I identify an Aluminum Mobile Home Feeder (MHF) Wire?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou can see four quadruplexed compacted conductors made of AA-8000 seriesaluminum alloy twisted together with any of the following specifications–\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRHH\u003c\/li\u003e\n\u003cli\u003eRHW-2\u003c\/li\u003e\n\u003cli\u003eUSE-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe four conductors have unique features such as the following –\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNeutral conductor – Has an insulation made of black cross-linked polyethylene with a white stripe.\u003c\/li\u003e\n\u003cli\u003ePhase conductors – There are two of them which are triple extruded. Their insulation is made of black cross-linked polyethylene (XLP). The Polarity ID is shown by a thin red stripe on the insulation surface of one of the phase conductors.\u003c\/li\u003e\n\u003cli\u003eGrounding conductor- This also has cross-linked polyethylene insulation, which has a green overall coating.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eYou can also find out that they are made of Aluminum when you strip the conductors off their insulation. You will see that the wires are a light gray rather than a coppery color as it would be if they were made of Copper.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\" data-mce-style=\"text-decoration: underline;\"\u003eWhat are the differences between RHH, RHW-2 and USE-2?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen it is Type RHH, it is suitable for dry locations and the conductor temperature should not become more than 90°C.  RHW-2 can be used in wet or dry locations but the temperature requirement is the same as RHH. USE-2 then it is suitable for underground use, in both wet and dry locations with the same temperature requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\" data-mce-style=\"text-decoration: underline;\"\u003eWhat are the different sizes of Aluminum Mobile Home Feeder that are available?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e You can get them in three sizes and they can be with or without the reduced neutral such as the following –\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e100 ampere rating\u003c\/li\u003e\n\u003cli\u003e150 ampere rating\u003c\/li\u003e\n\u003cli\u003e200 ampere rating\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\" data-mce-style=\"text-decoration: underline;\"\u003eMy electrician recommends that I go in for Copper than Aluminum cables for my mobile home. What do you recommend?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePreviously, when aluminum cables were used, the aluminum used to oxidize when exposed to air which will then prevent the flow of electricity. As a result the cable can get hot and even lead to fire. However, today the scenario is different and aluminum cables come with a protective oxidization cover which prevents oxidization. So you can safely go in for Aluminum Mobile Home Feeders.\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27241879306340,"sku":"NNC0001X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_1_af26a151-06ac-413e-8ffe-59b20ee18fd9.png?v=1758958732"},{"product_id":"aluminum-xlp-use-2-rhh-rhw-2-direct-burial-building-wire","title":"Aluminum XLP USE-2 RHH\/RHW-2 Direct Burial Building Wire","description":"\u003cp\u003e[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/AL_XLP.pdf?v=1724417087\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cp\u003e[short] \u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003eAluminum XLP USE-2 RHH\/RHW-2 Direct Burial Building Wire\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eApplications:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eUSE-2 cables are power distribution cables for service entrance below ground and direct burial, as well as raceways. The electrical cable is approved according to the National Electric Code, except for the use in cable trays. The maximum operating temperature for this electrical cable is 90°C in wet and dry locations. The voltage rating is 600 volts.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eAlso Known As:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eAluminum rhh wire, aluminum rhw cable, aluminum bury cable, direct burial electrical cable, direct burial power cable, direct burial cable, direct burial service entrance cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eUL 44\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eUL 854\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eNEMA WC 70\/ICEA S-95-658\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eRequirements of the National Electrical Code\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eASTM B800, B801, B836\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eSunlight resistant\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eOil Resistant PRI\/PRII\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eGas and Oil Res GRI\/GRII\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eRUS ACCEPTED\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConstruction\u003c\/h3\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eConductors:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eCompact bare 8000 series aluminum, with Class B stranding per ASTM. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eInsulation:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003eAbrasion, heat and moisture resistant cross-linked polyethylene insulation (XLP)\u003c\/p\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eALUMINUM RHH\/RHW-2\/USE-2 90°C XLPE INSULATION 600V\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis type of aluminum cable is also rated at 600 volts just as its name implies. It can operate in temperatures not exceeding 900C. It primarily used for power distribution but cannot be installed in cable trays unlike other types of aluminum cables. It is also heat and moisture resistant.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAluminum home feeder cable has a compact stranded soft drawn 8000 series aluminum conductor in accordance to ASTM B-800 or B-801. The conductor is the electrode in the cable and is responsible for transmitting electric current.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt has cross-linked polyethylene (XLP) insulation. The conductors are normally cabled together with XLP insulated aluminum ground or bare copper ground and covered with a reinforced binder tape. XLP insulation is tough and is resistant to impact, abrasion, chemicals, acids, oils, industrial solvents and changes in weather.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable jacket:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable jacket used in its design is polyvinyl Chloride (PVC). The jacket protects the inner components of the cable from external forces that may cause damage to it. PVC is robust and is resistant to oil, sunlight, water, flames, acids, chemicals, radiation, impact, abrasion and weather changes. On the cable jacket are sequential footage markings that help the user identify the appropriate length during installation without guess work.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial ratings and approvals:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e• National Electric Code (NEC)\u003cbr\u003e• UL 44 for types RHH \u0026amp; RHW-2 \u003cbr\u003e• UL 854 for type USE-2\u003cbr\u003e• ASTM standards B 800, B 801 \u003cbr\u003e• Sunlight resistant \u003cbr\u003e• RUS ACCEPTED\u003cbr\u003e• For dwelling units, conductors shall be permitted at listed Ampacities to be utilized as 120\/240 volt, 3-wire, single phase service \u003cbr\u003e• Ampacities based on National Electric Code , 2005 edition, section 310-15\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQuestion and Answer:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eFrequently Asked Questions - \u003c\/b\u003e\u003cb\u003eAluminum RHH\/RHW-2\/USE-2 90°C\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan style=\"text-decoration: underline;\"\u003eAny special instructions I should follow while using \u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan style=\"text-decoration: underline;\"\u003eAluminum RHH\/RHW-2\/USE-2 90°C?\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eAluminum RHH\/RHW-2\/USE-2 90°C cables are designed for use in power distribution within raceways as per the National Electrical Code. While the cables are not rated to be used in cable tray, they should be used in applications of about 600 volts and you should make sure that the temperatures don’t exceed 90 degrees Celsius.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan style=\"text-decoration: underline;\"\u003eWhat are the specifications of Aluminum RHH\/RHW-2\/USE-2 90°C cables?\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe cables are listed UL 44 and meet ASTM standards B 800 and B 801. They also meet the requirements of the National Electrical Code and are RUS accepted.  \u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan style=\"text-decoration: underline;\"\u003eHow can I identify an Aluminum RHH\/RHW-2\/USE-2 90°C cable?\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eIt has compacted conductors that are made of aluminum alloy AA-8000 series and these conductors have RHH, RHW-2, and USE-2 specifications. When you strip off the insulation of the conductor, you will see that they are made using aluminum material which appears light gray instead of the coppery color you find with copper wires. When you look at the insulation, it is made of cross-linked polyethylene (XLPE).\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan style=\"text-decoration: underline;\"\u003eWhat does RHH, RHW-2, and USE-2 mean?\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eType RHH cable means that it is designed to work in dry locations however, the temperature should not exceed 90 degrees Celsius. With RHW-2, it implies that the cable can be used in both wet and dry locations however, the temperature should not be more than 90 degrees Celsius. USE-2 is therefore suitable for underground services within dry and wet locations but the temperature requirement should not be more than 90 degrees Celsius.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan style=\"text-decoration: underline;\"\u003eShould I use copper instead of aluminum cable? \u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eIn the past, aluminum cables had a tendency of oxidizing after they have been exposed to air and this prevents flow of electricity. The aluminum cables used in the past could often become hot and at times, they could result in fire. This was unsafe, but today, with advancement in the engineering of aluminum cables, they are safe. The aluminum cables designed today have a protective cover to prevent oxidation. Therefore, you can consider using aluminum cables such as Aluminum RHH\/RHW-2\/USE-2 90°C. \u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27485362618468,"sku":"NNC3139X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/Product2.png?v=1759804661"},{"product_id":"ser","title":"ALUMINUM SER SERVICE ENTRANCE TYPE R CABLE","description":"[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/AL_SER_c399d3c5-7230-41dd-b3ad-c648db249ba5.pdf?v=1685789059\"\u003e [\/pdf]\n\u003ch2\u003eALUMINUM SER SERVICE ENTRANCE TYPE R CABLE\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eApplications:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003eAluminum service entrance cable is mainly used in branch circuits and panel feeders. The voltage rating for this electrical cable is 600 volts. Aluminum s\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eervice entrance cables\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e are designed for use in adverse weather conditions, with operating temperatures being 90\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e°\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eC in both wet and dry locations. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003eHowever, type R cables can operate at 60\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e°\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eC when terminated to equipment for circuits rated at 100 Amps or less or if it is marked for 14 gauge through 1 gauge conductors. In addition, SER cables can operate at 70\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e°\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eC when the electrical cable is terminated to equipment in circuits rated over 100 Amps or when marked for conductors larger than 1 gauge.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eAlso Known As:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eType r cable, service entrance cable, ser cable, aluminum ser cable, aluminum service entrance cable, electrical entrance cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eStandards:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eAmpacities based on National Electric Code, 2005 edition, section 310-15 \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e60°C when terminated to equipment for circuits rated 100 Amps or less or marked for 14 gauge through 1 gauge conductors \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e70°C when terminated to equipment for circuits rated over 100 Amps or marked for conductors larger than 1 gauge \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e90°C wet or dry locations \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eFor dwelling units, conductors shall be permitted at listed ampacities to be utilized as 120\/240 volt, 3-wire, single-phase service conductors that supply the total load \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eUL 44\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eConstruction\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eConductors:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eAluminum type R cable has \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003ecompact strand soft drawn 8000 series aluminum conductor, per ASTM B-801.\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e The conductor is the electrode in the cable and is responsible for transmitting electric current. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eInsulation:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eAluminum SER cable has a type XHHW-2 cross-linked polyethylene (XLP) insulation. The conductors are cabled together with a bare aluminum ground and covered with reinforced binder tape. For color code, see table B in the technical section. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eJacket:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe cable jacket used in its design is Polyvinyl Chloride (PVC). The jacket protects the inner components of the cable from potentially damaging external forces. PVC is robust and resistant to oil, sunlight, water, flames, acids, chemicals, radiation, impact, abrasion, and weather changes. Sequential footage markings that help the user identify the appropriate length during installation are noted on the cable jacket.\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27485362651236,"sku":"NNC3140X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/ALMSERCUADRUPLX20251_eeef23bd-e829-4e0a-b9a9-f268896d23da.png?v=1762458406"},{"product_id":"seu","title":"ALUMINUM SEU CABLE","description":"[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/AL_SEU_10c202a9-b0f4-491a-9834-88efae503486.pdf?v=1685791016\"\u003e [\/pdf]\n\u003cp\u003e[short] \u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003eALUMINUM SEU CABLE\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eApplications:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eAluminum SEU cable is primarily used as panel feeder in multiple unit dwellings and for branch circuits. Maximum operating temperature of this electrical cable is not to exceed 90°C in wet locations. Voltage rating for this electrical cable is 600 volts. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eAlso Known As:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eAluminum seu cable, seu service entrance cable, seu cable, seu wire, \u003cspan data-mce-fragment=\"1\"\u003e600v wire, 600v cable\u003c\/span\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eStandards:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eAmpacities based on National Electric Code, 2005 edition, section 310-15 \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e60°C when terminated to equipment for circuits rated 100 Amps or less or marked for 14 gauge through 1 gauge conductors \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e70°C when terminated to equipment for circuits rated over 100 Amps or marked for conductors larger than 1 gauge \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e90°C wet or dry locations \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eFor dwelling units, conductors shall be permitted at listed ampacities to be utilized as 120\/240 volt, 3-wire, single-phase service conductors that supply the total load \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eUL 44, 854 \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eFederal Specification J-C - 30B\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eConstruction\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eConductors:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eAluminum SEU cable has \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003ecompact strand soft drawn 8000 series aluminum conductor, per ASTM B-801.\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e The conductor is the electrode in the cable and is responsible for transmitting electric current. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eInsulation:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eAluminum SEU cable has a type XHHW-2 cross-linked polyethylene (XLP) insulation. The conductors are cabled together with a bare aluminum ground and covered with a reinforced binder tape. For color code, see table B in the technical section. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eJacket:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe cable jacket used in its design is Polyvinyl Chloride (PVC). The jacket protects the inner components of the cable from potentially damaging external forces. PVC is robust and resistant to oil, sunlight, water, flames, acids, chemicals, radiation, impact, abrasion, and weather changes. Sequential footage markings that help the user identify the appropriate length during installation are noted on the cable jacket.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n[\/short]\n\u003cp\u003e\u003cb\u003eAluminum SEU\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable operates in wet and dry places with a maximum of up to 90 degrees Celsius. It is meant for 600 voltage loads hence it is advisable not to use it in systems with high voltage demand.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cb\u003eConductors\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAluminum SEU cable is made up of aluminum conductors which are designed into a compact. The compact comprises of strands of 8000 series of softly drowned aluminum conductors as per ASTM B-801.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cb\u003eInsulation and Jacket\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eA robust type \u003ca href=\"https:\/\/www.nassaunationalcable.com\/wire-and-cable\/aluminum\/building\/xhhw-2.html\"\u003eXHHW-2\u003c\/a\u003e cross linked polyethylene XLP material forms the insulation feature of Aluminum SEU cable. A binder tape helps to secure the conductors which are bound up together with a bare ground copper conductor. Copper is a very good conductor, therefore it is used to act as a ground for the whole configuration.\u003c\/p\u003e\n\u003cp\u003eGray sun light resistant polyvinyl chloride jacket is an enhanced security feature for the entire cable\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cb\u003eStandards\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNational Electric Code, 2005 edition, section 310-15\u003c\/p\u003e\n\u003cp\u003eUL 44, 854\u003c\/p\u003e\n\u003cp\u003eFederal Specification J-C - 30B\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cb\u003eApplication\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAluminum SEU cable is technically applied to act as a panel feeder so that it supplies power to various multiple units in a house. Besides, it is also used in branching circuits into other channels or paths. Circuit branching is a very laborious process which requires that you only use the cable designed to it, failure to which you end up with a less robust circuit which can fail at any time. To guarantee that your circuit shall be resilient and efficient, use the Aluminum SEU cable.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQusetion and Answer:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan style=\"text-decoration: underline;\"\u003eFrequently Asked Questions - \u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan style=\"text-decoration: underline;\"\u003eAluminum SEU\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan style=\"text-decoration: underline;\"\u003eWhat special instructions should I follow when using Aluminum SEU?\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eAluminum SEU is a cable used as panel feeder within multiple unit buildings but it may also be used for branch circuits. When using this cable, there are instructions you need to follow. While you may use the cables in wet locations, you should not exceed operating temperatures of 90 degrees Celsius. The voltage rating should be 600 volts. When using the cables, if they are terminated to equipment having circuits rated 100amps or less, the maximum temperature rating should be 60 degrees Celsius. If the circuits are rated over 100amps, then the temperatures can be up to 70 degrees Celsius. Generally, you should not exceed temperature of 90 degrees Celsius whether in dry or wet locations.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan style=\"text-decoration: underline;\"\u003eHow are Aluminum SEU cables constructed?\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eAluminum SEU cable consists of compact strands made using 8000 series aluminum material. The cables have an insulation cover made of cross linked polyethylene (XLP) TYPE XHHW-2 and the conductors are cabled alongside a bare copper ground with a reinforced binder tape cover. A polyvinyl chloride (PVC) jacket is used for enhanced protection.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan style=\"text-decoration: underline;\"\u003eHow can I identify Aluminum SEU cable?\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable has compacted strands made of 8000 series aluminum and have XHHW-2 specification. If you strip off the insulation, you will see the conductor look light grayish, which is the color of aluminum. The insulation is made of cross linked polyethylene and the jacket is looks gray and is made of polyvinyl chloride (PVC).\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan style=\"text-decoration: underline;\"\u003eWhat are the specifications of Aluminum SEU cable?\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe Aluminum SEU cables are designed with 8000 series aluminum alloy meeting ASTM B-801 requirements. They are listed UL 44 and UL 854 while also meeting Federal Specification J-C- 30B. Aluminum SEU cables, when used for dwelling units, they need to be used at the listed ampacities and at 120\/240 volts in single phase service. The ampacities are based on NEC section 310-15 of the 2005 edition.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan style=\"text-decoration: underline;\"\u003eIs there a difference between SEU and SER cables?\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eYes, there is a difference between these two wires. Although both are Service Entrance (SE) cables, SER have a reinforcement tape and SEU cables have an overall reinforcement together with neutral tape. SEU cables may be used in applications of 600 volts and under, but SER cable is used in applications of 600 volts.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27485362749540,"sku":"NNC3141X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/Product4.png?v=1762458925"},{"product_id":"xhhw-2","title":"Aluminum XHHW-2 Cable 600V","description":"\u003cp\u003e[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Aluminum_XHHW_COM_1_1.pdf?v=1782224138\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch2\u003eAluminum XHHW-2 Cable 600V\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eApplications:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eType XHHW-2\/RW90 wires are primarily used in conduit or recognized raceways for services, feeders, and branch circuit wiring as specified in the National Electrical Code or the Canadian Electrical Code. XHHW-2\/RW90 conductors may be used in wet or dry locations at temperatures not to exceed 90oC. Voltage rating for XHHW-2 conductors is 600 or 1000 volts, or 600 volts for RW90. Cable tray rated for 1\/0 AWG and larger available upon request.\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eAlso Known As:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eXhhw cable, hxxw cable, rw90 cable, rw90 wire, type se cable style u type xhhw, xhhw, southwire xhhw, xhhw insulation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eStandards:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eXHHW-2 meet or exceed the following standards: \u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eUL standard 44 \u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eRequirements of the National Electrical Code \u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eASTM standards B 800, B 801 \u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eFederal Specification J–C-30B \u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eSunlight resistant\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eConstruction\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eConductors:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003eCompact bare AA-8000 series aluminum alloy, Class B stranded per ASTM\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eInsulation:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eXHHW-2 has abrasion, heat, and moisture resistant cross-linked polyethylene insulation. Cross linking a polyethylene helps to achieve an excellent strength that makes the material suitable for covering this cable used in harsh conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27485362815076,"sku":"NNC3142X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Black_fd6ba594-c4b3-4e83-b66c-11cb1983110e.png?v=1781672796"},{"product_id":"aluminum-solar-photovoltaic-2kv-pv-wire","title":"Aluminum Solar Photovoltaic 2KV PV Wire","description":"[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Aluminum_2KV_Photovoltaic_NNC.pdf?v=1741166370\"\u003e [\/pdf]\n\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch2\u003eAluminum Solar Photovoltaic 2KV PV Wire\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eApplications:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003cspan\u003e2KV PV wire, or photovoltaic cable, is an electrical wire that plays a big role in solar applications due to a wide temperature range with a cold bend of -40°C to 90°C. The most common use of the photovoltaic wire is \u003c\/span\u003e\u003cspan\u003efor grounded and ungrounded photovoltaic power systems, particularly their interconnection wiring, up to 2000V.\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eThe compressed 8000 series aluminum conductor for this electrical cable has good thermal and electrical conductivity, improving the PV cable’s flexibility and performance.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eAlso Known As:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003ePhotovoltaic cable, photovoltaic wire, pv cable, 2kv pv wire, solar pv wire, solar pv cable, aluminum alloy cable, all aluminum alloy conductor, abrasive resistant cable. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eStandards:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eASTM B-800 \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eASTM B-836 \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eASTM B-901 \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eUL Listed PV wire under UL 44 and UL 4703\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eConstruction\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eConductors:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe PV cable conductor is an 8000 series aluminum conductor. These conductors are also light, soft, and flexible, hence easy to work with, especially during installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eInsulation:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe solar PV wire has a black color coded cross linked polyethylene (XLP) insulation, which improves the service life of the cable. XLP is resistant to abrasion, heat, corrosive chemicals, moisture, and sunlight, making the cable withstand the punishing outdoor conditions. Due to color coding, it is easily identifiable and non-conducting, which keeps the user safe from shocks.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n[\/short]\n\u003cp\u003e\u003cstrong\u003eALUMINUM 2KV SOLAR PHOTOVOLTAIC (PV)CABLE\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe photovoltaic cable plays a big role in solar applications. This cable has a wide temperature range with a cold bend of -40 degrees and 90 degrees in hot temperatures. The cable is made of 8000 series of Aluminum conductors and insulated with a cross linked polyethylene which is black colour coded, this ensures easy identification of the cable.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eStandards and Approvals\u003c\/b\u003e\u003c\/p\u003e\n\u003cli\u003eASTM B-800\u003c\/li\u003e\n\u003cli\u003eASTM B-836\u003c\/li\u003e\n\u003cli\u003eASTM B-901\u003c\/li\u003e\n\u003cli\u003eUnderwriters Laboratory (UL) listed photovoltaic wire, UL 44 \u0026amp; UL 4703\u003c\/li\u003e\n\u003cli\u003eMeets requirements by the NEC\n\u003cp\u003e\u003cb\u003eFeatures\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eConductor\u003c\/b\u003e\n\u003cp\u003eThe compacted and compressed 800 series Aluminum have good thermal and electrical conductivity, improving the cable’s performance. These conductors are also soft and flexible thus not labour demanding especially during installation. The conductor also has a long flex life. The conductor is also light hence easy to use and move around.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eInsulation\u003c\/b\u003e\n\u003cp\u003eThe cross linked polyethylene insulation improves the service life of the cable. XLP is abrasive resistive, heat resistant, corrosive chemicals resistance; moisture and sunlight resistant making the cable withstand the punishing outdoor conditions. It is colour coded for easy identification. This layer is also non-conducting and keeps the user safe from shocks.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eApplications\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe Photovoltaic Wire is designed for interconnections of grounded and ungrounded wirings. It is used in photovoltaic systems to serve 2000 volts. The cable is a dual serving and can operate in both wet and dry locations with at working temperature ratings of -40\u003csup\u003e0\u003c\/sup\u003eC to 90\u003csup\u003e0\u003c\/sup\u003eC. It can be used as a power cable in industries.\u003c\/p\u003e\n\u003c\/li\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27485363535972,"sku":"NNC3153X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_89.png?v=1762458931"},{"product_id":"thhn-thwn-2-aluminum-cable-pvc-insulation-nylon-jacket-600v","title":"THHN THWN-2 Aluminum Cable PVC Insulation Nylon Jacket 600V","description":"\u003cp\u003e[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/AL_THHNCom.pdf?v=1781507998\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003eTHHN THWN-2 Aluminum Cable PVC Insulation Nylon Jacket 600V\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eApplications:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe electrical wires known as THHN \/ THWN-2 \/ T90 cables are primarily used for power distribution, in both wet and dry places, with ambient temperatures not exceeding 90°C. The voltage rating of this electrical wire, XHHW-2 cable, is 600V. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eAlso Known As:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThhn cable, thwn cable, thhn aluminum, pvc insulated, pvc insulated wire, pvc insulated aluminium wire, pvc sheathed cable, pvc flexible cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eStandards:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eUL standard 83, 1685, CUL\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eCSA C22.2 No. 75\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e1\/0 \u0026amp; larger are rated for CT use\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eRequirements of the National Electrical Code\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eNEMA WC-70 construction requirements\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eASTM standards B 800, B 801, B836\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eFederal Specification AA-59544\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eSunlight resistant\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eRoHS Compliant\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003eConstruction\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eConductors:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003eCompact bare AA-8000 series aluminum, with Class B stranded per ASTM\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eInsulation:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eTHHN \/ THWN-2 \/ T90 has abrasion, heat, moisture, oil, and acid alkaline resistant polyvinyl chloride (PVC) insulation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eJacket:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eTHHN \/ THWN-2 \/ T90 cables have a clear abrasion, heat, sunlight, moisture resistant, and low coefficient of friction nylon jacket. Standard stock colors include: black, red, blue, white, brown, orange, yellow, gray, purple, and green.\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27755175673956,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/ChatGPT_Image_Jun_15_2026_12_00_13_PM.png?v=1781507944"},{"product_id":"type-tc-tc-er-jp-aluminum-generator-cable","title":"Type TC\/TC-ER-JP Aluminum Generator Cable","description":"\u003ch2\u003eType TC\/TC-ER-JP Aluminum Generator Cable\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eA multi-conductor all-in-one cable for connecting a generator to a transfer switch. A multi-conductor\u003cspan\u003e all-in-one cable for connecting a generator to a transfer switch. JP (Joist Pull) rated per the 2017 NEC 336.10(9). Black jacket and color-coded inner conductors.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003eGenerator Cable, Type TC\/TC-ER-JP, Multi-Conductor Generator Cable, PVC Generator Cable, Type TC Cable, Type TC-ER Wire, Generator Wire, joist Pull Generator Cable, Aluminum Generator Cable, Black Generator Cable.\u003c\/p\u003e\n\u003ch3\u003eConstruction:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e• Element 1: Aluminum 8000 series\u003cbr\u003e• Element 2: Annealed bare Aluminum Class K\u003cbr\u003e• Element 3: Aluminum 8000 series\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e• Element 1, 2 \u0026amp; 3: Polyvinylchloride (PVC) \u0026amp; Nylon\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e• Sunlight resistant and direct burial approved PVC with ripcord rated 90°C wet or dry per UL 1277\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAssembly:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAll 3 Elements or Conductors are cabled together with Non-Hygroscopic Polypropylene fillers as required for a circular cross-section with a clear mylar binder tape and jacketed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e• Element 1: Black, White, Red\u003cbr\u003e• Element 2: Black, Red, Yellow, Yellow\/Black, Blue, White, White\/Blue, Purple, Purple\/Black\u003cbr\u003e• Element 3: Green Ground\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e• \u003c\/span\u003eUL Listed as TC-ER-JP per UL Standard 1277\u003cbr\u003e• Rated 90°C wet or dry to meet UL 83 for THHN\/THWN\u003cbr\u003e• Meets cold bend test at -40°C\u003cbr\u003e• ICEA S-73-532. ICEA S-95-658, where applicable\u003cbr\u003e• Meets UL 1581 \u0026amp; 1202 (FT-4) 70,000 BTU\/HR \u0026amp; ICEA T-29-520 210,000 BTU\/HR requirements\u003cbr\u003e• REACH compliant per Regulation (EC) No 1907\/2006 (233) Updated January 17, 2023\u003cbr\u003e• Cable is suitable for use in Class I Division 2 hazardous locations\u003cbr\u003e• Element 1 \u0026amp; 2 conductors pass UL VW-1 flame test, rated THWN\/VW-1\u003cbr\u003e• ASTM B3, B8, B174, B787\u003cbr\u003e• UL approved for Direct Burial \u0026amp; Sunlight Resistant\u003cbr\u003eApplications\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e***THIS MATERIAL IS NON-RETURNABLE***\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eAll values are nominal and subject to correction.\u003cbr\u003e*Ampacity according to NEC 310.15(B)(16) @30°C THWN 75°C insulated wires.\u003cbr\u003e**Installations shall follow NEC, applicable correcting factors shall be considered when conditions vary.\u003c\/p\u003e","brand":"NassauNationalCable","offers":[{"title":"Default Title","offer_id":55279664562545,"sku":"TC\/TC-ER-JPAL","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1-03TCGAL-18-06-VN_300x300_ed18c02a-b02e-4d3e-9e6a-2b1730691da3.jpg?v=1763025756"},{"product_id":"solid-bare-aluminum-wire","title":"Solid Bare Aluminum Wire","description":"","brand":"NassauNationalCable","offers":[{"title":"Default Title","offer_id":63308543361393,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/ChatGPTImageMar19_2026_09_23_55AM_1ff5619f-4d46-4d87-b2c2-696170bc9bcb.png?v=1773899522"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/collections\/ALUMINUM_XHHW_SER.jpg?v=1619593308","url":"https:\/\/nassaunationalcable.com\/collections\/https-nassaunationalcable-com-collections-aluminum-rhh-rhw-2-use-2-90-c-xlpe-insulation-600v.oembed","provider":"NassauNationalCable","version":"1.0","type":"link"}