{"title":"HELUKABEL PAAR-TRONIC PVC DATA CABLE","description":"","products":[{"product_id":"26-awg-1p-helukabel-19001-paar-tronic-pvc-data-cable","title":"26 AWG 1P Helukabel 19001 PAAR-TRONIC PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M19001_EN_GB_1.pdf?v=1766476446\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 1P Helukabel 19001 PAAR-TRONIC PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Used as a control and signal cable in electronic engineering, measurement and control technology and wherever wiring must be executed using the smallest possible outside diameter, with consideration of electronic possibilities, e.g. computer systems, signal technology, scales etc. \u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 1P HELUKABEL PAAR-TRONIC PVC cable, PAAR-TRONIC data cable, HELUKABEL industrial data cable, PVC data control cable HELUKABEL, PAAR-TRONIC twisted pair cable, HELUKABEL signal transmission cable, 26 AWG 1P HELUKABEL low voltage data cable, PAAR-TRONIC control \u0026amp; data cable, 26 AWG 1P HELUKABEL PVC shielded data cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -30°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e350 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e1200 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e2400 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003eat 800 Hz 0.14 - 0.25 mm²: approx. 100 pF\/m 0.34 - 0.75 mm²: approx. 150\u003cbr\u003epF\/m\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 300 pF\/100m\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance\u003cbr\u003e\u003c\/strong\u003e78 Ohm, (approx. value)\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003c\/strong\u003e\u003cbr\u003eapprox. 0.65 mH\/km\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 0.75 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths, Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7032)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e26 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 1 x 2 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 3.3\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e2.7\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e20.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62827250909553,"sku":"NNC19001","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1-Photoroom_2_e26ed4ae-03c6-425e-93d5-ac2f798f1c1a.png?v=1766477492"},{"product_id":"26-awg-2p-helukabel-19002-paar-tronic-pvc-data-cable","title":"26 AWG 2P Helukabel 19002 PAAR-TRONIC PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M19001_EN_GB_1.pdf?v=1766476446\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 2P Helukabel 19002 PAAR-TRONIC PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Used as a control and signal cable in electronic engineering, measurement and control technology and wherever wiring must be executed using the smallest possible outside diameter, with consideration of electronic possibilities, e.g. computer systems, signal technology, scales etc. \u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 2P HELUKABEL PAAR-TRONIC PVC cable, PAAR-TRONIC data cable, HELUKABEL industrial data cable, PVC data control cable HELUKABEL, PAAR-TRONIC twisted pair cable, HELUKABEL signal transmission cable, 26 AWG 2P HELUKABEL low voltage data cable, PAAR-TRONIC control \u0026amp; data cable, 26 AWG 2P HELUKABEL PVC shielded data cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -30°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e350 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e1200 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e2400 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003eat 800 Hz 0.14 - 0.25 mm²: approx. 100 pF\/m 0.34 - 0.75 mm²: approx. 150\u003cbr\u003epF\/m\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 300 pF\/100m\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance\u003cbr\u003e\u003c\/strong\u003e78 Ohm, (approx. value)\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003c\/strong\u003e\u003cbr\u003eapprox. 0.65 mH\/km\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 0.75 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths, Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7032)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e26 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 2 x 2 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 4.7\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e5.4\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e25.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62827254153585,"sku":"NNC19002","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1-Photoroom_2_e26ed4ae-03c6-425e-93d5-ac2f798f1c1a.png?v=1766477492"},{"product_id":"26-awg-3p-helukabel-19003-paar-tronic-pvc-data-cable","title":"26 AWG 3P Helukabel 19003 PAAR-TRONIC PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M19001_EN_GB_1.pdf?v=1766476446\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 3P Helukabel 19003 PAAR-TRONIC PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Used as a control and signal cable in electronic engineering, measurement and control technology and wherever wiring must be executed using the smallest possible outside diameter, with consideration of electronic possibilities, e.g. computer systems, signal technology, scales etc. \u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 3P HELUKABEL PAAR-TRONIC PVC cable, PAAR-TRONIC data cable, HELUKABEL industrial data cable, PVC data control cable HELUKABEL, PAAR-TRONIC twisted pair cable, HELUKABEL signal transmission cable, 26 AWG 3P HELUKABEL low voltage data cable, PAAR-TRONIC control \u0026amp; data cable, 26 AWG 3P HELUKABEL PVC shielded data cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -30°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e350 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e1200 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e2400 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003eat 800 Hz 0.14 - 0.25 mm²: approx. 100 pF\/m 0.34 - 0.75 mm²: approx. 150\u003cbr\u003epF\/m\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 300 pF\/100m\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance\u003cbr\u003e\u003c\/strong\u003e78 Ohm, (approx. value)\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003c\/strong\u003e\u003cbr\u003eapprox. 0.65 mH\/km\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 0.75 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths, Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7032)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e26 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 3 x 2 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 5.0\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e8.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e31.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62827256185201,"sku":"NNC19003","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1-Photoroom_2_e26ed4ae-03c6-425e-93d5-ac2f798f1c1a.png?v=1766477492"},{"product_id":"26-awg-4p-helukabel-19004-paar-tronic-pvc-data-cable","title":"26 AWG 4P Helukabel 19004 PAAR-TRONIC PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M19001_EN_GB_1.pdf?v=1766476446\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 4P Helukabel 19004 PAAR-TRONIC PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Used as a control and signal cable in electronic engineering, measurement and control technology and wherever wiring must be executed using the smallest possible outside diameter, with consideration of electronic possibilities, e.g. computer systems, signal technology, scales etc. \u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 4P HELUKABEL PAAR-TRONIC PVC cable, PAAR-TRONIC data cable, HELUKABEL industrial data cable, PVC data control cable HELUKABEL, PAAR-TRONIC twisted pair cable, HELUKABEL signal transmission cable, 26 AWG 4P HELUKABEL low voltage data cable, PAAR-TRONIC control \u0026amp; data cable, 26 AWG 4P HELUKABEL PVC shielded data cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -30°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e350 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e1200 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e2400 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003eat 800 Hz 0.14 - 0.25 mm²: approx. 100 pF\/m 0.34 - 0.75 mm²: approx. 150\u003cbr\u003epF\/m\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 300 pF\/100m\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance\u003cbr\u003e\u003c\/strong\u003e78 Ohm, (approx. value)\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003c\/strong\u003e\u003cbr\u003eapprox. 0.65 mH\/km\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 0.75 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths, Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7032)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e26 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 4 x 2 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 5.4\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e10.7\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e38.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62827268178289,"sku":"NNC19004","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1-Photoroom_2_e26ed4ae-03c6-425e-93d5-ac2f798f1c1a.png?v=1766477492"},{"product_id":"26-awg-5p-helukabel-19005-paar-tronic-pvc-data-cable","title":"26 AWG 5P Helukabel 19005 PAAR-TRONIC PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M19001_EN_GB_1.pdf?v=1766476446\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 5P Helukabel 19005 PAAR-TRONIC PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Used as a control and signal cable in electronic engineering, measurement and control technology and wherever wiring must be executed using the smallest possible outside diameter, with consideration of electronic possibilities, e.g. computer systems, signal technology, scales etc. \u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 5P HELUKABEL PAAR-TRONIC PVC cable, PAAR-TRONIC data cable, HELUKABEL industrial data cable, PVC data control cable HELUKABEL, PAAR-TRONIC twisted pair cable, HELUKABEL signal transmission cable, 26 AWG 5P HELUKABEL low voltage data cable, PAAR-TRONIC control \u0026amp; data cable, 26 AWG 5P HELUKABEL PVC shielded data cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -30°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e350 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e1200 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e2400 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003eat 800 Hz 0.14 - 0.25 mm²: approx. 100 pF\/m 0.34 - 0.75 mm²: approx. 150\u003cbr\u003epF\/m\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 300 pF\/100m\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance\u003cbr\u003e\u003c\/strong\u003e78 Ohm, (approx. value)\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003c\/strong\u003e\u003cbr\u003eapprox. 0.65 mH\/km\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 0.75 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths, Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7032)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e26 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 5 x 2 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 5.9\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e13.4\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e45.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62827277287793,"sku":"NNC19005","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1-Photoroom_2_e26ed4ae-03c6-425e-93d5-ac2f798f1c1a.png?v=1766477492"},{"product_id":"26-awg-6p-helukabel-19006-paar-tronic-pvc-data-cable","title":"26 AWG 6P Helukabel 19006 PAAR-TRONIC PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M19001_EN_GB_1.pdf?v=1766476446\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 6P Helukabel 19006 PAAR-TRONIC PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Used as a control and signal cable in electronic engineering, measurement and control technology and wherever wiring must be executed using the smallest possible outside diameter, with consideration of electronic possibilities, e.g. computer systems, signal technology, scales etc. \u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 6P HELUKABEL PAAR-TRONIC PVC cable, PAAR-TRONIC data cable, HELUKABEL industrial data cable, PVC data control cable HELUKABEL, PAAR-TRONIC twisted pair cable, HELUKABEL signal transmission cable, 26 AWG 6P HELUKABEL low voltage data cable, PAAR-TRONIC control \u0026amp; data cable, 26 AWG 6P HELUKABEL PVC shielded data cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -30°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e350 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e1200 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e2400 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003eat 800 Hz 0.14 - 0.25 mm²: approx. 100 pF\/m 0.34 - 0.75 mm²: approx. 150\u003cbr\u003epF\/m\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 300 pF\/100m\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance\u003cbr\u003e\u003c\/strong\u003e78 Ohm, (approx. value)\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003c\/strong\u003e\u003cbr\u003eapprox. 0.65 mH\/km\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 0.75 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths, Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7032)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e26 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 6 x 2 x 0.14 \u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 6.6\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e16.1\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e50.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62827277582705,"sku":"NNC19006","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1-Photoroom_2_e26ed4ae-03c6-425e-93d5-ac2f798f1c1a.png?v=1766477492"},{"product_id":"26-awg-7p-helukabel-19007-paar-tronic-pvc-data-cable","title":"26 AWG 7P Helukabel 19007 PAAR-TRONIC PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M19001_EN_GB_1.pdf?v=1766476446\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 7P Helukabel 19007 PAAR-TRONIC PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Used as a control and signal cable in electronic engineering, measurement and control technology and wherever wiring must be executed using the smallest possible outside diameter, with consideration of electronic possibilities, e.g. computer systems, signal technology, scales etc. \u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 7P HELUKABEL PAAR-TRONIC PVC cable, PAAR-TRONIC data cable, HELUKABEL industrial data cable, PVC data control cable HELUKABEL, PAAR-TRONIC twisted pair cable, HELUKABEL signal transmission cable, 26 AWG 7P HELUKABEL low voltage data cable, PAAR-TRONIC control \u0026amp; data cable, 26 AWG 7P HELUKABEL PVC shielded data cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -30°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e350 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e1200 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e2400 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003eat 800 Hz 0.14 - 0.25 mm²: approx. 100 pF\/m 0.34 - 0.75 mm²: approx. 150\u003cbr\u003epF\/m\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 300 pF\/100m\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance\u003cbr\u003e\u003c\/strong\u003e78 Ohm, (approx. value)\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003c\/strong\u003e\u003cbr\u003eapprox. 0.65 mH\/km\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 0.75 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths, Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7032)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e26 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 7 x 2 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 6.6\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e18.8\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e57.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62827278958961,"sku":"NNC19007","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1-Photoroom_2_e26ed4ae-03c6-425e-93d5-ac2f798f1c1a.png?v=1766477492"},{"product_id":"26-awg-8p-helukabel-19008-paar-tronic-pvc-data-cable","title":"26 AWG 8P Helukabel 19008 PAAR-TRONIC PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M19001_EN_GB_1.pdf?v=1766476446\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 8P Helukabel 19008 PAAR-TRONIC PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Used as a control and signal cable in electronic engineering, measurement and control technology and wherever wiring must be executed using the smallest possible outside diameter, with consideration of electronic possibilities, e.g. computer systems, signal technology, scales etc. \u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 8P HELUKABEL PAAR-TRONIC PVC cable, PAAR-TRONIC data cable, HELUKABEL industrial data cable, PVC data control cable HELUKABEL, PAAR-TRONIC twisted pair cable, HELUKABEL signal transmission cable, 26 AWG 8P HELUKABEL low voltage data cable, PAAR-TRONIC control \u0026amp; data cable, 26 AWG 8P HELUKABEL PVC shielded data cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -30°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e350 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e1200 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e2400 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003eat 800 Hz 0.14 - 0.25 mm²: approx. 100 pF\/m 0.34 - 0.75 mm²: approx. 150\u003cbr\u003epF\/m\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 300 pF\/100m\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance\u003cbr\u003e\u003c\/strong\u003e78 Ohm, (approx. value)\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003c\/strong\u003e\u003cbr\u003eapprox. 0.65 mH\/km\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 0.75 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths, Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7032)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e26 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 8 x 2 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 7.6\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e21.5\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e64.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62827280367985,"sku":"NNC19008","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1-Photoroom_2_e26ed4ae-03c6-425e-93d5-ac2f798f1c1a.png?v=1766477492"},{"product_id":"26-awg-10p-helukabel-19009-paar-tronic-pvc-data-cable","title":"26 AWG 10P Helukabel 19009 PAAR-TRONIC PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M19001_EN_GB_1.pdf?v=1766476446\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 10P Helukabel 19009 PAAR-TRONIC PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Used as a control and signal cable in electronic engineering, measurement and control technology and wherever wiring must be executed using the smallest possible outside diameter, with consideration of electronic possibilities, e.g. computer systems, signal technology, scales etc. \u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 10P HELUKABEL PAAR-TRONIC PVC cable, PAAR-TRONIC data cable, HELUKABEL industrial data cable, PVC data control cable HELUKABEL, PAAR-TRONIC twisted pair cable, HELUKABEL signal transmission cable, 26 AWG 10P HELUKABEL low voltage data cable, PAAR-TRONIC control \u0026amp; data cable, 26 AWG 10P HELUKABEL PVC shielded data cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -30°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e350 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e1200 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e2400 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003eat 800 Hz 0.14 - 0.25 mm²: approx. 100 pF\/m 0.34 - 0.75 mm²: approx. 150\u003cbr\u003epF\/m\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 300 pF\/100m\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance\u003cbr\u003e\u003c\/strong\u003e78 Ohm, (approx. value)\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003c\/strong\u003e\u003cbr\u003eapprox. 0.65 mH\/km\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 0.75 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths, Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7032)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e26 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 10 x 2 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 8.3\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e26.9\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e78.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62827281187185,"sku":"NNC19009","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1-Photoroom_2_e26ed4ae-03c6-425e-93d5-ac2f798f1c1a.png?v=1766477492"},{"product_id":"26-awg-11p-helukabel-19010-paar-tronic-pvc-data-cable","title":"26 AWG 11P Helukabel 19010 PAAR-TRONIC PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M19001_EN_GB_1.pdf?v=1766476446\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 11P Helukabel 19010 PAAR-TRONIC PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Used as a control and signal cable in electronic engineering, measurement and control technology and wherever wiring must be executed using the smallest possible outside diameter, with consideration of electronic possibilities, e.g. computer systems, signal technology, scales etc. \u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 11P HELUKABEL PAAR-TRONIC PVC cable, PAAR-TRONIC data cable, HELUKABEL industrial data cable, PVC data control cable HELUKABEL, PAAR-TRONIC twisted pair cable, HELUKABEL signal transmission cable, 26 AWG 11P HELUKABEL low voltage data cable, PAAR-TRONIC control \u0026amp; data cable, 26 AWG 11P HELUKABEL PVC shielded data cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -30°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e350 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e1200 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e2400 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003eat 800 Hz 0.14 - 0.25 mm²: approx. 100 pF\/m 0.34 - 0.75 mm²: approx. 150\u003cbr\u003epF\/m\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 300 pF\/100m\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance\u003cbr\u003e\u003c\/strong\u003e78 Ohm, (approx. value)\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003c\/strong\u003e\u003cbr\u003eapprox. 0.65 mH\/km\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 0.75 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths, Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7032)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e26 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 11 x 2 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 8.8\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e29.5\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e86.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62828724584817,"sku":"NNC19010","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1-Photoroom_2_e26ed4ae-03c6-425e-93d5-ac2f798f1c1a.png?v=1766477492"},{"product_id":"26-awg-12p-helukabel-19011-paar-tronic-pvc-data-cable","title":"26 AWG 12P Helukabel 19011 PAAR-TRONIC PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M19001_EN_GB_1.pdf?v=1766476446\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 12P Helukabel 19011 PAAR-TRONIC PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Used as a control and signal cable in electronic engineering, measurement and control technology and wherever wiring must be executed using the smallest possible outside diameter, with consideration of electronic possibilities, e.g. computer systems, signal technology, scales etc. \u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 12P HELUKABEL PAAR-TRONIC PVC cable, PAAR-TRONIC data cable, HELUKABEL industrial data cable, PVC data control cable HELUKABEL, PAAR-TRONIC twisted pair cable, HELUKABEL signal transmission cable, 26 AWG 12P HELUKABEL low voltage data cable, PAAR-TRONIC control \u0026amp; data cable, 26 AWG 12P HELUKABEL PVC shielded data cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -30°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e350 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e1200 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e2400 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003eat 800 Hz 0.14 - 0.25 mm²: approx. 100 pF\/m 0.34 - 0.75 mm²: approx. 150\u003cbr\u003epF\/m\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 300 pF\/100m\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance\u003cbr\u003e\u003c\/strong\u003e78 Ohm, (approx. value)\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003c\/strong\u003e\u003cbr\u003eapprox. 0.65 mH\/km\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 0.75 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths, Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7032)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e26 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 12 x 2 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 8.8\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e32.3\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e94.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62828730122609,"sku":"NNC19011","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1-Photoroom_2_e26ed4ae-03c6-425e-93d5-ac2f798f1c1a.png?v=1766477492"},{"product_id":"26-awg-14p-helukabel-19012-paar-tronic-pvc-data-cable","title":"26 AWG 14P Helukabel 19012 PAAR-TRONIC PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M19001_EN_GB_1.pdf?v=1766476446\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 14P Helukabel 19012 PAAR-TRONIC PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Used as a control and signal cable in electronic engineering, measurement and control technology and wherever wiring must be executed using the smallest possible outside diameter, with consideration of electronic possibilities, e.g. computer systems, signal technology, scales etc. \u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 14P HELUKABEL PAAR-TRONIC PVC cable, PAAR-TRONIC data cable, HELUKABEL industrial data cable, PVC data control cable HELUKABEL, PAAR-TRONIC twisted pair cable, HELUKABEL signal transmission cable, 26 AWG 14P HELUKABEL low voltage data cable, PAAR-TRONIC control \u0026amp; data cable, 26 AWG 14P HELUKABEL PVC shielded data cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -30°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e350 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e1200 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e2400 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003eat 800 Hz 0.14 - 0.25 mm²: approx. 100 pF\/m 0.34 - 0.75 mm²: approx. 150\u003cbr\u003epF\/m\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 300 pF\/100m\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance\u003cbr\u003e\u003c\/strong\u003e78 Ohm, (approx. value)\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003c\/strong\u003e\u003cbr\u003eapprox. 0.65 mH\/km\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 0.75 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths, Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7032)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e26 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 14 x 2 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 9.2\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e37.6\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e105.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62828734808433,"sku":"NNC19012","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1-Photoroom_2_e26ed4ae-03c6-425e-93d5-ac2f798f1c1a.png?v=1766477492"},{"product_id":"26-awg-15p-helukabel-19013-paar-tronic-pvc-data-cable","title":"26 AWG 15P Helukabel 19013 PAAR-TRONIC PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M19001_EN_GB_1.pdf?v=1766476446\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 15P Helukabel 19013 PAAR-TRONIC PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Used as a control and signal cable in electronic engineering, measurement and control technology and wherever wiring must be executed using the smallest possible outside diameter, with consideration of electronic possibilities, e.g. computer systems, signal technology, scales etc. \u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 15P HELUKABEL PAAR-TRONIC PVC cable, PAAR-TRONIC data cable, HELUKABEL industrial data cable, PVC data control cable HELUKABEL, PAAR-TRONIC twisted pair cable, HELUKABEL signal transmission cable, 26 AWG 15P HELUKABEL low voltage data cable, PAAR-TRONIC control \u0026amp; data cable, 26 AWG 15P HELUKABEL PVC shielded data cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -30°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e350 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e1200 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e2400 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003eat 800 Hz 0.14 - 0.25 mm²: approx. 100 pF\/m 0.34 - 0.75 mm²: approx. 150\u003cbr\u003epF\/m\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 300 pF\/100m\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance\u003cbr\u003e\u003c\/strong\u003e78 Ohm, (approx. value)\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003c\/strong\u003e\u003cbr\u003eapprox. 0.65 mH\/km\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 0.75 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths, Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7032)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e26 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 15 x 2 x 0.14 \u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 9.7\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e40.3\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e108.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62828739821937,"sku":"NNC19013","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1-Photoroom_2_e26ed4ae-03c6-425e-93d5-ac2f798f1c1a.png?v=1766477492"},{"product_id":"26-awg-16p-helukabel-19014-paar-tronic-pvc-data-cable","title":"26 AWG 16P Helukabel 19014 PAAR-TRONIC PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M19001_EN_GB_1.pdf?v=1766476446\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 16P Helukabel 19014 PAAR-TRONIC PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Used as a control and signal cable in electronic engineering, measurement and control technology and wherever wiring must be executed using the smallest possible outside diameter, with consideration of electronic possibilities, e.g. computer systems, signal technology, scales etc. \u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 16P HELUKABEL PAAR-TRONIC PVC cable, PAAR-TRONIC data cable, HELUKABEL industrial data cable, PVC data control cable HELUKABEL, PAAR-TRONIC twisted pair cable, HELUKABEL signal transmission cable, 26 AWG 16P HELUKABEL low voltage data cable, PAAR-TRONIC control \u0026amp; data cable, 26 AWG 16P HELUKABEL PVC shielded data cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -30°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e350 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e1200 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e2400 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003eat 800 Hz 0.14 - 0.25 mm²: approx. 100 pF\/m 0.34 - 0.75 mm²: approx. 150\u003cbr\u003epF\/m\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 300 pF\/100m\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance\u003cbr\u003e\u003c\/strong\u003e78 Ohm, (approx. value)\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003c\/strong\u003e\u003cbr\u003eapprox. 0.65 mH\/km\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 0.75 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths, Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7032)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e26 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 16 x 2 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 9.7\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e43.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e110.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62828747915633,"sku":"NNC19014","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1-Photoroom_2_e26ed4ae-03c6-425e-93d5-ac2f798f1c1a.png?v=1766477492"},{"product_id":"26-awg-18p-helukabel-19015-paar-tronic-pvc-data-cable","title":"26 AWG 18P Helukabel 19015 PAAR-TRONIC PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M19001_EN_GB_1.pdf?v=1766476446\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 18P Helukabel 19015 PAAR-TRONIC PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Used as a control and signal cable in electronic engineering, measurement and control technology and wherever wiring must be executed using the smallest possible outside diameter, with consideration of electronic possibilities, e.g. computer systems, signal technology, scales etc. \u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 18P HELUKABEL PAAR-TRONIC PVC cable, PAAR-TRONIC data cable, HELUKABEL industrial data cable, PVC data control cable HELUKABEL, PAAR-TRONIC twisted pair cable, HELUKABEL signal transmission cable, 26 AWG 18P HELUKABEL low voltage data cable, PAAR-TRONIC control \u0026amp; data cable, 26 AWG 18P HELUKABEL PVC shielded data cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -30°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e350 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e1200 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e2400 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003eat 800 Hz 0.14 - 0.25 mm²: approx. 100 pF\/m 0.34 - 0.75 mm²: approx. 150\u003cbr\u003epF\/m\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 300 pF\/100m\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance\u003cbr\u003e\u003c\/strong\u003e78 Ohm, (approx. value)\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003c\/strong\u003e\u003cbr\u003eapprox. 0.65 mH\/km\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 0.75 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths, Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7032)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e26 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 18 x 2 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 10.2\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e48.4\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e119.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62828752601457,"sku":"NNC19015","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1-Photoroom_2_e26ed4ae-03c6-425e-93d5-ac2f798f1c1a.png?v=1766477492"},{"product_id":"26-awg-20p-helukabel-19016-paar-tronic-pvc-data-cable","title":"26 AWG 20P Helukabel 19016 PAAR-TRONIC PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M19001_EN_GB_1.pdf?v=1766476446\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 20P Helukabel 19016 PAAR-TRONIC PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Used as a control and signal cable in electronic engineering, measurement and control technology and wherever wiring must be executed using the smallest possible outside diameter, with consideration of electronic possibilities, e.g. computer systems, signal technology, scales etc. \u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 20P HELUKABEL PAAR-TRONIC PVC cable, PAAR-TRONIC data cable, HELUKABEL industrial data cable, PVC data control cable HELUKABEL, PAAR-TRONIC twisted pair cable, HELUKABEL signal transmission cable, 26 AWG 20P HELUKABEL low voltage data cable, PAAR-TRONIC control \u0026amp; data cable, 26 AWG 20P HELUKABEL PVC shielded data cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -30°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e350 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e1200 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e2400 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003eat 800 Hz 0.14 - 0.25 mm²: approx. 100 pF\/m 0.34 - 0.75 mm²: approx. 150\u003cbr\u003epF\/m\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 300 pF\/100m\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance\u003cbr\u003e\u003c\/strong\u003e78 Ohm, (approx. value)\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003c\/strong\u003e\u003cbr\u003eapprox. 0.65 mH\/km\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 0.75 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths, Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7032)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e26 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 20 x 2 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 10.9\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e54.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e130.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62828753781105,"sku":"NNC19016","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1-Photoroom_2_e26ed4ae-03c6-425e-93d5-ac2f798f1c1a.png?v=1766477492"},{"product_id":"26-awg-22p-helukabel-19017-paar-tronic-pvc-data-cable","title":"26 AWG 22P Helukabel 19017 PAAR-TRONIC PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M19001_EN_GB_1.pdf?v=1766476446\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 22P Helukabel 19017 PAAR-TRONIC PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Used as a control and signal cable in electronic engineering, measurement and control technology and wherever wiring must be executed using the smallest possible outside diameter, with consideration of electronic possibilities, e.g. computer systems, signal technology, scales etc. \u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 22P HELUKABEL PAAR-TRONIC PVC cable, PAAR-TRONIC data cable, HELUKABEL industrial data cable, PVC data control cable HELUKABEL, PAAR-TRONIC twisted pair cable, HELUKABEL signal transmission cable, 26 AWG 22P HELUKABEL low voltage data cable, PAAR-TRONIC control \u0026amp; data cable, 26 AWG 22P HELUKABEL PVC shielded data cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -30°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e350 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e1200 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e2400 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003eat 800 Hz 0.14 - 0.25 mm²: approx. 100 pF\/m 0.34 - 0.75 mm²: approx. 150\u003cbr\u003epF\/m\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 300 pF\/100m\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance\u003cbr\u003e\u003c\/strong\u003e78 Ohm, (approx. value)\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003c\/strong\u003e\u003cbr\u003eapprox. 0.65 mH\/km\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 0.75 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths, Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7032)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e26 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 22 x 2 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 12.1\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e59.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e150.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62828753977713,"sku":"NNC19017","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1-Photoroom_2_e26ed4ae-03c6-425e-93d5-ac2f798f1c1a.png?v=1766477492"},{"product_id":"26-awg-24p-helukabel-19018-paar-tronic-pvc-data-cable","title":"26 AWG 24P Helukabel 19018 PAAR-TRONIC PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M19001_EN_GB_1.pdf?v=1766476446\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 24P Helukabel 19018 PAAR-TRONIC PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Used as a control and signal cable in electronic engineering, measurement and control technology and wherever wiring must be executed using the smallest possible outside diameter, with consideration of electronic possibilities, e.g. computer systems, signal technology, scales etc. \u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 24P HELUKABEL PAAR-TRONIC PVC cable, PAAR-TRONIC data cable, HELUKABEL industrial data cable, PVC data control cable HELUKABEL, PAAR-TRONIC twisted pair cable, HELUKABEL signal transmission cable, 26 AWG 24P HELUKABEL low voltage data cable, PAAR-TRONIC control \u0026amp; data cable, 26 AWG 24P HELUKABEL PVC shielded data cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -30°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e350 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e1200 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e2400 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003eat 800 Hz 0.14 - 0.25 mm²: approx. 100 pF\/m 0.34 - 0.75 mm²: approx. 150\u003cbr\u003epF\/m\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 300 pF\/100m\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance\u003cbr\u003e\u003c\/strong\u003e78 Ohm, (approx. value)\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003c\/strong\u003e\u003cbr\u003eapprox. 0.65 mH\/km\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 0.75 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths, Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7032)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e26 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 24 x 2 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 12.1\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e65.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e170.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62828755943793,"sku":"NNC19018","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1-Photoroom_2_e26ed4ae-03c6-425e-93d5-ac2f798f1c1a.png?v=1766477492"},{"product_id":"26-awg-25p-helukabel-19019-paar-tronic-pvc-data-cable","title":"26 AWG 25P Helukabel 19019 PAAR-TRONIC PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M19001_EN_GB_1.pdf?v=1766476446\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 25P Helukabel 19019 PAAR-TRONIC PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Used as a control and signal cable in electronic engineering, measurement and control technology and wherever wiring must be executed using the smallest possible outside diameter, with consideration of electronic possibilities, e.g. computer systems, signal technology, scales etc. \u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 25P HELUKABEL PAAR-TRONIC PVC cable, PAAR-TRONIC data cable, HELUKABEL industrial data cable, PVC data control cable HELUKABEL, PAAR-TRONIC twisted pair cable, HELUKABEL signal transmission cable, 26 AWG 25P HELUKABEL low voltage data cable, PAAR-TRONIC control \u0026amp; data cable, 26 AWG 25P HELUKABEL PVC shielded data cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -30°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e350 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e1200 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e2400 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003eat 800 Hz 0.14 - 0.25 mm²: approx. 100 pF\/m 0.34 - 0.75 mm²: approx. 150\u003cbr\u003epF\/m\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 300 pF\/100m\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance\u003cbr\u003e\u003c\/strong\u003e78 Ohm, (approx. value)\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003c\/strong\u003e\u003cbr\u003eapprox. 0.65 mH\/km\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 0.75 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths, Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7032)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e26 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 25 x 2 x 0.14 \u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 12.4\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e67.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e180.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62828756337009,"sku":"NNC19019","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1-Photoroom_2_e26ed4ae-03c6-425e-93d5-ac2f798f1c1a.png?v=1766477492"},{"product_id":"26-awg-26p-helukabel-19020-paar-tronic-pvc-data-cable","title":"26 AWG 26P Helukabel 19020 PAAR-TRONIC PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M19001_EN_GB_1.pdf?v=1766476446\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 26P Helukabel 19020 PAAR-TRONIC PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Used as a control and signal cable in electronic engineering, measurement and control technology and wherever wiring must be executed using the smallest possible outside diameter, with consideration of electronic possibilities, e.g. computer systems, signal technology, scales etc. \u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 26P HELUKABEL PAAR-TRONIC PVC cable, PAAR-TRONIC data cable, HELUKABEL industrial data cable, PVC data control cable HELUKABEL, PAAR-TRONIC twisted pair cable, HELUKABEL signal transmission cable, 26 AWG 26P HELUKABEL low voltage data cable, PAAR-TRONIC control \u0026amp; data cable, 26 AWG 26P HELUKABEL PVC shielded data cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -30°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e350 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e1200 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e2400 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003eat 800 Hz 0.14 - 0.25 mm²: approx. 100 pF\/m 0.34 - 0.75 mm²: approx. 150\u003cbr\u003epF\/m\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 300 pF\/100m\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance\u003cbr\u003e\u003c\/strong\u003e78 Ohm, (approx. value)\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003c\/strong\u003e\u003cbr\u003eapprox. 0.65 mH\/km\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 0.75 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths, Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7032)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e26 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 26 x 2 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 12.4\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e70.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e184.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62828759744881,"sku":"NNC19020","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1-Photoroom_2_e26ed4ae-03c6-425e-93d5-ac2f798f1c1a.png?v=1766477492"},{"product_id":"26-awg-27p-helukabel-19021-paar-tronic-pvc-data-cable","title":"26 AWG 27P Helukabel 19021 PAAR-TRONIC PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M19001_EN_GB_1.pdf?v=1766476446\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 27P Helukabel 19021 PAAR-TRONIC PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Used as a control and signal cable in electronic engineering, measurement and control technology and wherever wiring must be executed using the smallest possible outside diameter, with consideration of electronic possibilities, e.g. computer systems, signal technology, scales etc. \u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 27P HELUKABEL PAAR-TRONIC PVC cable, PAAR-TRONIC data cable, HELUKABEL industrial data cable, PVC data control cable HELUKABEL, PAAR-TRONIC twisted pair cable, HELUKABEL signal transmission cable, 26 AWG 27P HELUKABEL low voltage data cable, PAAR-TRONIC control \u0026amp; data cable, 26 AWG 27P HELUKABEL PVC shielded data cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -30°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e350 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e1200 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e2400 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003eat 800 Hz 0.14 - 0.25 mm²: approx. 100 pF\/m 0.34 - 0.75 mm²: approx. 150\u003cbr\u003epF\/m\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 300 pF\/100m\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance\u003cbr\u003e\u003c\/strong\u003e78 Ohm, (approx. value)\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003c\/strong\u003e\u003cbr\u003eapprox. 0.65 mH\/km\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 0.75 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths, Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7032)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e26 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 27 x 2 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 12.4\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e73.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e188.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62828763873649,"sku":"NNC19021","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1-Photoroom_2_e26ed4ae-03c6-425e-93d5-ac2f798f1c1a.png?v=1766477492"},{"product_id":"26-awg-28p-helukabel-19022-paar-tronic-pvc-data-cable","title":"26 AWG 28P Helukabel 19022 PAAR-TRONIC PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M19001_EN_GB_1.pdf?v=1766476446\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 28P Helukabel 19022 PAAR-TRONIC PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Used as a control and signal cable in electronic engineering, measurement and control technology and wherever wiring must be executed using the smallest possible outside diameter, with consideration of electronic possibilities, e.g. computer systems, signal technology, scales etc. \u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 28P HELUKABEL PAAR-TRONIC PVC cable, PAAR-TRONIC data cable, HELUKABEL industrial data cable, PVC data control cable HELUKABEL, PAAR-TRONIC twisted pair cable, HELUKABEL signal transmission cable, 26 AWG 28P HELUKABEL low voltage data cable, PAAR-TRONIC control \u0026amp; data cable, 26 AWG 28P HELUKABEL PVC shielded data cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -30°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e350 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e1200 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e2400 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003eat 800 Hz 0.14 - 0.25 mm²: approx. 100 pF\/m 0.34 - 0.75 mm²: approx. 150\u003cbr\u003epF\/m\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 300 pF\/100m\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance\u003cbr\u003e\u003c\/strong\u003e78 Ohm, (approx. value)\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003c\/strong\u003e\u003cbr\u003eapprox. 0.65 mH\/km\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 0.75 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths, Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7032)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e26 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 28 x 2 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 12.4\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e75.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e192.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62828769476977,"sku":"NNC19022","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1-Photoroom_2_e26ed4ae-03c6-425e-93d5-ac2f798f1c1a.png?v=1766477492"},{"product_id":"26-awg-30p-helukabel-19023-paar-tronic-pvc-data-cable","title":"26 AWG 30P Helukabel 19023 PAAR-TRONIC PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M19001_EN_GB_1.pdf?v=1766476446\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 30P Helukabel 19023 PAAR-TRONIC PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Used as a control and signal cable in electronic engineering, measurement and control technology and wherever wiring must be executed using the smallest possible outside diameter, with consideration of electronic possibilities, e.g. computer systems, signal technology, scales etc. \u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 30P HELUKABEL PAAR-TRONIC PVC cable, PAAR-TRONIC data cable, HELUKABEL industrial data cable, PVC data control cable HELUKABEL, PAAR-TRONIC twisted pair cable, HELUKABEL signal transmission cable, 26 AWG 30P HELUKABEL low voltage data cable, PAAR-TRONIC control \u0026amp; data cable, 26 AWG 30P HELUKABEL PVC shielded data cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -30°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e350 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e1200 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e2400 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003eat 800 Hz 0.14 - 0.25 mm²: approx. 100 pF\/m 0.34 - 0.75 mm²: approx. 150\u003cbr\u003epF\/m\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 300 pF\/100m\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance\u003cbr\u003e\u003c\/strong\u003e78 Ohm, (approx. value)\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003c\/strong\u003e\u003cbr\u003eapprox. 0.65 mH\/km\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 0.75 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths, Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7032)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e26 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 30 x 2 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 13.0\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e81.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e200.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62828770066801,"sku":"NNC19023","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1-Photoroom_2_e26ed4ae-03c6-425e-93d5-ac2f798f1c1a.png?v=1766477492"},{"product_id":"26-awg-32p-helukabel-19024-paar-tronic-pvc-data-cable","title":"26 AWG 32P Helukabel 19024 PAAR-TRONIC PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M19001_EN_GB_1.pdf?v=1766476446\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 32P Helukabel 19024 PAAR-TRONIC PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Used as a control and signal cable in electronic engineering, measurement and control technology and wherever wiring must be executed using the smallest possible outside diameter, with consideration of electronic possibilities, e.g. computer systems, signal technology, scales etc. \u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 32P HELUKABEL PAAR-TRONIC PVC cable, PAAR-TRONIC data cable, HELUKABEL industrial data cable, PVC data control cable HELUKABEL, PAAR-TRONIC twisted pair cable, HELUKABEL signal transmission cable, 26 AWG 32P HELUKABEL low voltage data cable, PAAR-TRONIC control \u0026amp; data cable, 26 AWG 32P HELUKABEL PVC shielded data cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -30°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e350 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e1200 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e2400 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003eat 800 Hz 0.14 - 0.25 mm²: approx. 100 pF\/m 0.34 - 0.75 mm²: approx. 150\u003cbr\u003epF\/m\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 300 pF\/100m\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance\u003cbr\u003e\u003c\/strong\u003e78 Ohm, (approx. value)\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003c\/strong\u003e\u003cbr\u003eapprox. 0.65 mH\/km\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 0.75 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths, Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7032)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e26 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 32 x 2 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 13.2\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e86.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e224.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62828775309681,"sku":"NNC19024","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1-Photoroom_2_e26ed4ae-03c6-425e-93d5-ac2f798f1c1a.png?v=1766477492"},{"product_id":"26-awg-34p-helukabel-19025-paar-tronic-pvc-data-cable","title":"26 AWG 34P Helukabel 19025 PAAR-TRONIC PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M19001_EN_GB_1.pdf?v=1766476446\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 34P Helukabel 19025 PAAR-TRONIC PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Used as a control and signal cable in electronic engineering, measurement and control technology and wherever wiring must be executed using the smallest possible outside diameter, with consideration of electronic possibilities, e.g. computer systems, signal technology, scales etc. \u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 34P HELUKABEL PAAR-TRONIC PVC cable, PAAR-TRONIC data cable, HELUKABEL industrial data cable, PVC data control cable HELUKABEL, PAAR-TRONIC twisted pair cable, HELUKABEL signal transmission cable, 26 AWG 34P HELUKABEL low voltage data cable, PAAR-TRONIC control \u0026amp; data cable, 26 AWG 34P HELUKABEL PVC shielded data cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -30°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e350 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e1200 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e2400 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003eat 800 Hz 0.14 - 0.25 mm²: approx. 100 pF\/m 0.34 - 0.75 mm²: approx. 150\u003cbr\u003epF\/m\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 300 pF\/100m\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance\u003cbr\u003e\u003c\/strong\u003e78 Ohm, (approx. value)\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003c\/strong\u003e\u003cbr\u003eapprox. 0.65 mH\/km\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 0.75 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths, Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7032)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e26 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 34 x 2 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 13.7\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e91.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e247.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62828778455409,"sku":"NNC19025","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1-Photoroom_2_e26ed4ae-03c6-425e-93d5-ac2f798f1c1a.png?v=1766477492"},{"product_id":"26-awg-36p-helukabel-19026-paar-tronic-pvc-data-cable","title":"26 AWG 36P Helukabel 19026 PAAR-TRONIC PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M19001_EN_GB_1.pdf?v=1766476446\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 36P Helukabel 19026 PAAR-TRONIC PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Used as a control and signal cable in electronic engineering, measurement and control technology and wherever wiring must be executed using the smallest possible outside diameter, with consideration of electronic possibilities, e.g. computer systems, signal technology, scales etc. \u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 36P HELUKABEL PAAR-TRONIC PVC cable, PAAR-TRONIC data cable, HELUKABEL industrial data cable, PVC data control cable HELUKABEL, PAAR-TRONIC twisted pair cable, HELUKABEL signal transmission cable, 26 AWG 36P HELUKABEL low voltage data cable, PAAR-TRONIC control \u0026amp; data cable, 26 AWG 36P HELUKABEL PVC shielded data cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -30°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e350 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e1200 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e2400 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003eat 800 Hz 0.14 - 0.25 mm²: approx. 100 pF\/m 0.34 - 0.75 mm²: approx. 150\u003cbr\u003epF\/m\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 300 pF\/100m\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance\u003cbr\u003e\u003c\/strong\u003e78 Ohm, (approx. value)\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003c\/strong\u003e\u003cbr\u003eapprox. 0.65 mH\/km\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 0.75 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths, Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7032)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e26 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 36 x 2 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 13.7\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e97.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e260.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62828783599985,"sku":"NNC19026","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1-Photoroom_2_e26ed4ae-03c6-425e-93d5-ac2f798f1c1a.png?v=1766477492"},{"product_id":"26-awg-38p-helukabel-19027-paar-tronic-pvc-data-cable","title":"26 AWG 38P Helukabel 19027 PAAR-TRONIC PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M19001_EN_GB_1.pdf?v=1766476446\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 38P Helukabel 19027 PAAR-TRONIC PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Used as a control and signal cable in electronic engineering, measurement and control technology and wherever wiring must be executed using the smallest possible outside diameter, with consideration of electronic possibilities, e.g. computer systems, signal technology, scales etc. \u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 38P HELUKABEL PAAR-TRONIC PVC cable, PAAR-TRONIC data cable, HELUKABEL industrial data cable, PVC data control cable HELUKABEL, PAAR-TRONIC twisted pair cable, HELUKABEL signal transmission cable, 26 AWG 38P HELUKABEL low voltage data cable, PAAR-TRONIC control \u0026amp; data cable, 26 AWG 38P HELUKABEL PVC shielded data cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -30°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e350 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e1200 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e2400 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003eat 800 Hz 0.14 - 0.25 mm²: approx. 100 pF\/m 0.34 - 0.75 mm²: approx. 150\u003cbr\u003epF\/m\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 300 pF\/100m\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance\u003cbr\u003e\u003c\/strong\u003e78 Ohm, (approx. value)\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003c\/strong\u003e\u003cbr\u003eapprox. 0.65 mH\/km\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 0.75 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths, Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7032)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e26 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 38 x 2 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 14.2\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e102.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e272.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62828822135153,"sku":"NNC19027","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1-Photoroom_2_e26ed4ae-03c6-425e-93d5-ac2f798f1c1a.png?v=1766477492"},{"product_id":"26-awg-40p-helukabel-19028-paar-tronic-pvc-data-cable","title":"26 AWG 40P Helukabel 19028 PAAR-TRONIC PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M19001_EN_GB_1.pdf?v=1766476446\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 40P Helukabel 19028 PAAR-TRONIC PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Used as a control and signal cable in electronic engineering, measurement and control technology and wherever wiring must be executed using the smallest possible outside diameter, with consideration of electronic possibilities, e.g. computer systems, signal technology, scales etc. \u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 40P HELUKABEL PAAR-TRONIC PVC cable, PAAR-TRONIC data cable, HELUKABEL industrial data cable, PVC data control cable HELUKABEL, PAAR-TRONIC twisted pair cable, HELUKABEL signal transmission cable, 26 AWG 40P HELUKABEL low voltage data cable, PAAR-TRONIC control \u0026amp; data cable, 26 AWG 40P HELUKABEL PVC shielded data cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -30°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e350 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e1200 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e2400 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003eat 800 Hz 0.14 - 0.25 mm²: approx. 100 pF\/m 0.34 - 0.75 mm²: approx. 150\u003cbr\u003epF\/m\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 300 pF\/100m\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance\u003cbr\u003e\u003c\/strong\u003e78 Ohm, (approx. value)\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003c\/strong\u003e\u003cbr\u003eapprox. 0.65 mH\/km\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 0.75 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths, Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7032)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e26 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 40 x 2 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 14.2\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e108.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e294.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62828832194929,"sku":"NNC19028","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1-Photoroom_2_e26ed4ae-03c6-425e-93d5-ac2f798f1c1a.png?v=1766477492"},{"product_id":"26-awg-44p-helukabel-19029-paar-tronic-pvc-data-cable","title":"26 AWG 44P Helukabel 19029 PAAR-TRONIC PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M19001_EN_GB_1.pdf?v=1766476446\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 44P Helukabel 19029 PAAR-TRONIC PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Used as a control and signal cable in electronic engineering, measurement and control technology and wherever wiring must be executed using the smallest possible outside diameter, with consideration of electronic possibilities, e.g. computer systems, signal technology, scales etc. \u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 44P HELUKABEL PAAR-TRONIC PVC cable, PAAR-TRONIC data cable, HELUKABEL industrial data cable, PVC data control cable HELUKABEL, PAAR-TRONIC twisted pair cable, HELUKABEL signal transmission cable, 26 AWG 44P HELUKABEL low voltage data cable, PAAR-TRONIC control \u0026amp; data cable, 26 AWG 44P HELUKABEL PVC shielded data cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -30°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e350 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e1200 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e2400 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003eat 800 Hz 0.14 - 0.25 mm²: approx. 100 pF\/m 0.34 - 0.75 mm²: approx. 150\u003cbr\u003epF\/m\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 300 pF\/100m\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance\u003cbr\u003e\u003c\/strong\u003e78 Ohm, (approx. value)\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003c\/strong\u003e\u003cbr\u003eapprox. 0.65 mH\/km\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 0.75 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths, Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7032)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e26 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 44 x 2 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 15.6\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e118.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e334.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62828852642161,"sku":"NNC19029","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1-Photoroom_2_e26ed4ae-03c6-425e-93d5-ac2f798f1c1a.png?v=1766477492"},{"product_id":"26-awg-45p-helukabel-19030-paar-tronic-pvc-data-cable","title":"26 AWG 45P Helukabel 19030 PAAR-TRONIC PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M19001_EN_GB_1.pdf?v=1766476446\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 45P Helukabel 19030 PAAR-TRONIC PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Used as a control and signal cable in electronic engineering, measurement and control technology and wherever wiring must be executed using the smallest possible outside diameter, with consideration of electronic possibilities, e.g. computer systems, signal technology, scales etc. \u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 45P HELUKABEL PAAR-TRONIC PVC cable, PAAR-TRONIC data cable, HELUKABEL industrial data cable, PVC data control cable HELUKABEL, PAAR-TRONIC twisted pair cable, HELUKABEL signal transmission cable, 26 AWG 45P HELUKABEL low voltage data cable, PAAR-TRONIC control \u0026amp; data cable, 26 AWG 45P HELUKABEL PVC shielded data cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -30°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e350 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e1200 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e2400 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003eat 800 Hz 0.14 - 0.25 mm²: approx. 100 pF\/m 0.34 - 0.75 mm²: approx. 150\u003cbr\u003epF\/m\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 300 pF\/100m\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance\u003cbr\u003e\u003c\/strong\u003e78 Ohm, (approx. value)\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003c\/strong\u003e\u003cbr\u003eapprox. 0.65 mH\/km\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 0.75 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths, Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7032)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e26 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 45 x 2 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 15.6\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e121.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e342.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62828860932465,"sku":"NNC19030","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1-Photoroom_2_e26ed4ae-03c6-425e-93d5-ac2f798f1c1a.png?v=1766477492"},{"product_id":"26-awg-50p-helukabel-19031-paar-tronic-pvc-data-cable","title":"26 AWG 50P Helukabel 19031 PAAR-TRONIC PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M19001_EN_GB_1.pdf?v=1766476446\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 50P Helukabel 19031 PAAR-TRONIC PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Used as a control and signal cable in electronic engineering, measurement and control technology and wherever wiring must be executed using the smallest possible outside diameter, with consideration of electronic possibilities, e.g. computer systems, signal technology, scales etc. \u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 50P HELUKABEL PAAR-TRONIC PVC cable, PAAR-TRONIC data cable, HELUKABEL industrial data cable, PVC data control cable HELUKABEL, PAAR-TRONIC twisted pair cable, HELUKABEL signal transmission cable, 26 AWG 50P HELUKABEL low voltage data cable, PAAR-TRONIC control \u0026amp; data cable, 26 AWG 50P HELUKABEL PVC shielded data cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -30°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e350 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e1200 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e2400 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003eat 800 Hz 0.14 - 0.25 mm²: approx. 100 pF\/m 0.34 - 0.75 mm²: approx. 150\u003cbr\u003epF\/m\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 300 pF\/100m\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance\u003cbr\u003e\u003c\/strong\u003e78 Ohm, (approx. value)\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003c\/strong\u003e\u003cbr\u003eapprox. 0.65 mH\/km\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 0.75 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths, Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7032)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e26 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 50 x 2 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 16.3\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e134.0 \u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e387.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62828871057777,"sku":"NNC19031","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1-Photoroom_2_e26ed4ae-03c6-425e-93d5-ac2f798f1c1a.png?v=1766477492"},{"product_id":"26-awg-52p-helukabel-19032-paar-tronic-pvc-data-cable","title":"26 AWG 52P Helukabel 19032 PAAR-TRONIC PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M19001_EN_GB_1.pdf?v=1766476446\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 52P Helukabel 19032 PAAR-TRONIC PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Used as a control and signal cable in electronic engineering, measurement and control technology and wherever wiring must be executed using the smallest possible outside diameter, with consideration of electronic possibilities, e.g. computer systems, signal technology, scales etc. \u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 52P HELUKABEL PAAR-TRONIC PVC cable, PAAR-TRONIC data cable, HELUKABEL industrial data cable, PVC data control cable HELUKABEL, PAAR-TRONIC twisted pair cable, HELUKABEL signal transmission cable, 26 AWG 52P HELUKABEL low voltage data cable, PAAR-TRONIC control \u0026amp; data cable, 26 AWG 52P HELUKABEL PVC shielded data cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -30°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e350 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e1200 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e2400 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003eat 800 Hz 0.14 - 0.25 mm²: approx. 100 pF\/m 0.34 - 0.75 mm²: approx. 150\u003cbr\u003epF\/m\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 300 pF\/100m\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance\u003cbr\u003e\u003c\/strong\u003e78 Ohm, (approx. value)\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003c\/strong\u003e\u003cbr\u003eapprox. 0.65 mH\/km\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 0.75 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths, Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7032)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e26 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 52 x 2 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 16.1\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e140.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e403.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62828882002289,"sku":"NNC19032","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1-Photoroom_2_e26ed4ae-03c6-425e-93d5-ac2f798f1c1a.png?v=1766477492"},{"product_id":"26-awg-55p-helukabel-19033-paar-tronic-pvc-data-cable","title":"26 AWG 55P Helukabel 19033 PAAR-TRONIC PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M19001_EN_GB_1.pdf?v=1766476446\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 55P Helukabel 19033 PAAR-TRONIC PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Used as a control and signal cable in electronic engineering, measurement and control technology and wherever wiring must be executed using the smallest possible outside diameter, with consideration of electronic possibilities, e.g. computer systems, signal technology, scales etc. \u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 55P HELUKABEL PAAR-TRONIC PVC cable, PAAR-TRONIC data cable, HELUKABEL industrial data cable, PVC data control cable HELUKABEL, PAAR-TRONIC twisted pair cable, HELUKABEL signal transmission cable, 26 AWG 55P HELUKABEL low voltage data cable, PAAR-TRONIC control \u0026amp; data cable, 26 AWG 55P HELUKABEL PVC shielded data cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -30°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e350 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e1200 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e2400 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003eat 800 Hz 0.14 - 0.25 mm²: approx. 100 pF\/m 0.34 - 0.75 mm²: approx. 150\u003cbr\u003epF\/m\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 300 pF\/100m\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance\u003cbr\u003e\u003c\/strong\u003e78 Ohm, (approx. value)\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003c\/strong\u003e\u003cbr\u003eapprox. 0.65 mH\/km\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 0.75 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths, Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7032)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e26 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 55 x 2 x 0.14 \u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 16.6\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e148.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e427.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62828888195441,"sku":"NNC19033","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1-Photoroom_2_e26ed4ae-03c6-425e-93d5-ac2f798f1c1a.png?v=1766477492"},{"product_id":"24-awg-1p-helukabel-19034-paar-tronic-pvc-data-cable","title":"24 AWG 1P Helukabel 19034 PAAR-TRONIC PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M19001_EN_GB_1.pdf?v=1766476446\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e24 AWG 1P Helukabel 19034 PAAR-TRONIC PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Used as a control and signal cable in electronic engineering, measurement and control technology and wherever wiring must be executed using the smallest possible outside diameter, with consideration of electronic possibilities, e.g. computer systems, signal technology, scales etc. \u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e24 AWG 1P HELUKABEL PAAR-TRONIC PVC cable, PAAR-TRONIC data cable, HELUKABEL industrial data cable, PVC data control cable HELUKABEL, PAAR-TRONIC twisted pair cable, HELUKABEL signal transmission cable, 24 AWG 1P HELUKABEL low voltage data cable, PAAR-TRONIC control \u0026amp; data cable, 24 AWG 1P HELUKABEL PVC shielded data cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -30°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e350 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e1200 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e2400 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003eat 800 Hz 0.14 - 0.25 mm²: approx. 100 pF\/m 0.34 - 0.75 mm²: approx. 150\u003cbr\u003epF\/m\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 300 pF\/100m\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance\u003cbr\u003e\u003c\/strong\u003e78 Ohm, (approx. value)\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003c\/strong\u003e\u003cbr\u003eapprox. 0.65 mH\/km\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 0.75 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths, Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7032)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e24 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 1 x 2 x 0.25\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 3.9\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e5.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e32.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62828891275633,"sku":"NNC19034","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1-Photoroom_2_e26ed4ae-03c6-425e-93d5-ac2f798f1c1a.png?v=1766477492"},{"product_id":"24-awg-2p-helukabel-19035-paar-tronic-pvc-data-cable","title":"24 AWG 2P Helukabel 19035 PAAR-TRONIC PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M19001_EN_GB_1.pdf?v=1766476446\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e24 AWG 2P Helukabel 19035 PAAR-TRONIC PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Used as a control and signal cable in electronic engineering, measurement and control technology and wherever wiring must be executed using the smallest possible outside diameter, with consideration of electronic possibilities, e.g. computer systems, signal technology, scales etc. \u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e24 AWG 2P HELUKABEL PAAR-TRONIC PVC cable, PAAR-TRONIC data cable, HELUKABEL industrial data cable, PVC data control cable HELUKABEL, PAAR-TRONIC twisted pair cable, HELUKABEL signal transmission cable, 24 AWG 2P HELUKABEL low voltage data cable, PAAR-TRONIC control \u0026amp; data cable, 24 AWG 2P HELUKABEL PVC shielded data cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -30°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e350 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e1200 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e2400 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003eat 800 Hz 0.14 - 0.25 mm²: approx. 100 pF\/m 0.34 - 0.75 mm²: approx. 150\u003cbr\u003epF\/m\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 300 pF\/100m\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance\u003cbr\u003e\u003c\/strong\u003e78 Ohm, (approx. value)\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003c\/strong\u003e\u003cbr\u003eapprox. 0.65 mH\/km\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 0.75 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths, Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7032)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e24 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 2 x 2 x 0.25\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 5.7\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e10.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e37.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62828892422513,"sku":"NNC19035","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1-Photoroom_2_e26ed4ae-03c6-425e-93d5-ac2f798f1c1a.png?v=1766477492"},{"product_id":"24-awg-3p-helukabel-19036-paar-tronic-pvc-data-cable","title":"24 AWG 3P Helukabel 19036 PAAR-TRONIC PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M19001_EN_GB_1.pdf?v=1766476446\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e24 AWG 3P Helukabel 19036 PAAR-TRONIC PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Used as a control and signal cable in electronic engineering, measurement and control technology and wherever wiring must be executed using the smallest possible outside diameter, with consideration of electronic possibilities, e.g. computer systems, signal technology, scales etc. \u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e24 AWG 3P HELUKABEL PAAR-TRONIC PVC cable, PAAR-TRONIC data cable, HELUKABEL industrial data cable, PVC data control cable HELUKABEL, PAAR-TRONIC twisted pair cable, HELUKABEL signal transmission cable, 24 AWG 3P HELUKABEL low voltage data cable, PAAR-TRONIC control \u0026amp; data cable, 24 AWG 3P HELUKABEL PVC shielded data cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -30°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e350 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e1200 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e2400 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003eat 800 Hz 0.14 - 0.25 mm²: approx. 100 pF\/m 0.34 - 0.75 mm²: approx. 150\u003cbr\u003epF\/m\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 300 pF\/100m\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance\u003cbr\u003e\u003c\/strong\u003e78 Ohm, (approx. value)\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003c\/strong\u003e\u003cbr\u003eapprox. 0.65 mH\/km\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 0.75 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths, Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7032)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e24 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 3 x 2 x 0.25\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 6.1\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e15.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e47.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62828898451825,"sku":"NNC19036","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1-Photoroom_2_e26ed4ae-03c6-425e-93d5-ac2f798f1c1a.png?v=1766477492"},{"product_id":"24-awg-4p-helukabel-19037-paar-tronic-pvc-data-cable","title":"24 AWG 4P Helukabel 19037 PAAR-TRONIC PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M19001_EN_GB_1.pdf?v=1766476446\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e24 AWG 4P Helukabel 19037 PAAR-TRONIC PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Used as a control and signal cable in electronic engineering, measurement and control technology and wherever wiring must be executed using the smallest possible outside diameter, with consideration of electronic possibilities, e.g. computer systems, signal technology, scales etc. \u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e24 AWG 4P HELUKABEL PAAR-TRONIC PVC cable, PAAR-TRONIC data cable, HELUKABEL industrial data cable, PVC data control cable HELUKABEL, PAAR-TRONIC twisted pair cable, HELUKABEL signal transmission cable, 24 AWG 4P HELUKABEL low voltage data cable, PAAR-TRONIC control \u0026amp; data cable, 24 AWG 4P HELUKABEL PVC shielded data cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -30°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e350 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e1200 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e2400 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003eat 800 Hz 0.14 - 0.25 mm²: approx. 100 pF\/m 0.34 - 0.75 mm²: approx. 150\u003cbr\u003epF\/m\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 300 pF\/100m\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance\u003cbr\u003e\u003c\/strong\u003e78 Ohm, (approx. value)\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003c\/strong\u003e\u003cbr\u003eapprox. 0.65 mH\/km\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 0.75 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths, Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7032)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e24 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 4 x 2 x 0.25\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 6.8\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e20.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e58.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62828901007729,"sku":"NNC19037","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1-Photoroom_2_e26ed4ae-03c6-425e-93d5-ac2f798f1c1a.png?v=1766477492"},{"product_id":"24-awg-5p-helukabel-19038-paar-tronic-pvc-data-cable","title":"24 AWG 5P Helukabel 19038 PAAR-TRONIC PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M19001_EN_GB_1.pdf?v=1766476446\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e24 AWG 5P Helukabel 19038 PAAR-TRONIC PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Used as a control and signal cable in electronic engineering, measurement and control technology and wherever wiring must be executed using the smallest possible outside diameter, with consideration of electronic possibilities, e.g. computer systems, signal technology, scales etc. \u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e24 AWG 5P HELUKABEL PAAR-TRONIC PVC cable, PAAR-TRONIC data cable, HELUKABEL industrial data cable, PVC data control cable HELUKABEL, PAAR-TRONIC twisted pair cable, HELUKABEL signal transmission cable, 24 AWG 5P HELUKABEL low voltage data cable, PAAR-TRONIC control \u0026amp; data cable, 24 AWG 5P HELUKABEL PVC shielded data cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -30°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e350 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e1200 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e2400 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003eat 800 Hz 0.14 - 0.25 mm²: approx. 100 pF\/m 0.34 - 0.75 mm²: approx. 150\u003cbr\u003epF\/m\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 300 pF\/100m\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance\u003cbr\u003e\u003c\/strong\u003e78 Ohm, (approx. value)\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003c\/strong\u003e\u003cbr\u003eapprox. 0.65 mH\/km\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 0.75 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths, Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7032)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e24 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 5 x 2 x 0.25\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 7.5\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e25.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e70.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62828907037041,"sku":"NNC19038","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1-Photoroom_2_e26ed4ae-03c6-425e-93d5-ac2f798f1c1a.png?v=1766477492"},{"product_id":"24-awg-6p-helukabel-19039-paar-tronic-pvc-data-cable","title":"24 AWG 6P Helukabel 19039 PAAR-TRONIC PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M19001_EN_GB_1.pdf?v=1766476446\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e24 AWG 6P Helukabel 19039 PAAR-TRONIC PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Used as a control and signal cable in electronic engineering, measurement and control technology and wherever wiring must be executed using the smallest possible outside diameter, with consideration of electronic possibilities, e.g. computer systems, signal technology, scales etc. \u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e24 AWG 6P HELUKABEL PAAR-TRONIC PVC cable, PAAR-TRONIC data cable, HELUKABEL industrial data cable, PVC data control cable HELUKABEL, PAAR-TRONIC twisted pair cable, HELUKABEL signal transmission cable, 24 AWG 6P HELUKABEL low voltage data cable, PAAR-TRONIC control \u0026amp; data cable, 24 AWG 6P HELUKABEL PVC shielded data cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -30°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e350 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e1200 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e2400 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003eat 800 Hz 0.14 - 0.25 mm²: approx. 100 pF\/m 0.34 - 0.75 mm²: approx. 150\u003cbr\u003epF\/m\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 300 pF\/100m\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance\u003cbr\u003e\u003c\/strong\u003e78 Ohm, (approx. value)\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003c\/strong\u003e\u003cbr\u003eapprox. 0.65 mH\/km\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 0.75 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths, Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7032)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e24 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 6 x 2 x 0.25\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 8.1\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e30.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e80.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62828918440305,"sku":"NNC19039","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1-Photoroom_2_e26ed4ae-03c6-425e-93d5-ac2f798f1c1a.png?v=1766477492"},{"product_id":"24-awg-7p-helukabel-19040-paar-tronic-pvc-data-cable","title":"24 AWG 7P Helukabel 19040 PAAR-TRONIC PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M19001_EN_GB_1.pdf?v=1766476446\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e24 AWG 7P Helukabel 19040 PAAR-TRONIC PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Used as a control and signal cable in electronic engineering, measurement and control technology and wherever wiring must be executed using the smallest possible outside diameter, with consideration of electronic possibilities, e.g. computer systems, signal technology, scales etc. \u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e24 AWG 7P HELUKABEL PAAR-TRONIC PVC cable, PAAR-TRONIC data cable, HELUKABEL industrial data cable, PVC data control cable HELUKABEL, PAAR-TRONIC twisted pair cable, HELUKABEL signal transmission cable, 24 AWG 7P HELUKABEL low voltage data cable, PAAR-TRONIC control \u0026amp; data cable, 24 AWG 7P HELUKABEL PVC shielded data cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -30°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e350 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e1200 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e2400 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003eat 800 Hz 0.14 - 0.25 mm²: approx. 100 pF\/m 0.34 - 0.75 mm²: approx. 150\u003cbr\u003epF\/m\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 300 pF\/100m\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance\u003cbr\u003e\u003c\/strong\u003e78 Ohm, (approx. value)\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003c\/strong\u003e\u003cbr\u003eapprox. 0.65 mH\/km\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 0.75 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths, Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7032)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e24 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 7 x 2 x 0.25\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 8.1\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e35.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e89.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62828920209777,"sku":"NNC19040","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1-Photoroom_2_e26ed4ae-03c6-425e-93d5-ac2f798f1c1a.png?v=1766477492"},{"product_id":"24-awg-8p-helukabel-19041-paar-tronic-pvc-data-cable","title":"24 AWG 8P Helukabel 19041 PAAR-TRONIC PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M19001_EN_GB_1.pdf?v=1766476446\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e24 AWG 8P Helukabel 19041 PAAR-TRONIC PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Used as a control and signal cable in electronic engineering, measurement and control technology and wherever wiring must be executed using the smallest possible outside diameter, with consideration of electronic possibilities, e.g. computer systems, signal technology, scales etc. \u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e24 AWG 8P HELUKABEL PAAR-TRONIC PVC cable, PAAR-TRONIC data cable, HELUKABEL industrial data cable, PVC data control cable HELUKABEL, PAAR-TRONIC twisted pair cable, HELUKABEL signal transmission cable, 24 AWG 8P HELUKABEL low voltage data cable, PAAR-TRONIC control \u0026amp; data cable, 24 AWG 8P HELUKABEL PVC shielded data cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -30°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e350 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e1200 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e2400 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003eat 800 Hz 0.14 - 0.25 mm²: approx. 100 pF\/m 0.34 - 0.75 mm²: approx. 150\u003cbr\u003epF\/m\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 300 pF\/100m\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance\u003cbr\u003e\u003c\/strong\u003e78 Ohm, (approx. value)\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003c\/strong\u003e\u003cbr\u003eapprox. 0.65 mH\/km\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 0.75 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths, Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7032)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e24 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 8 x 2 x 0.25\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 9.7\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e40.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e99.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62828922077553,"sku":"NNC19041","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1-Photoroom_2_e26ed4ae-03c6-425e-93d5-ac2f798f1c1a.png?v=1766477492"},{"product_id":"24-awg-10p-helukabel-19042-paar-tronic-pvc-data-cable","title":"24 AWG 10P Helukabel 19042 PAAR-TRONIC PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M19001_EN_GB_1.pdf?v=1766476446\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e24 AWG 10P Helukabel 19042 PAAR-TRONIC PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Used as a control and signal cable in electronic engineering, measurement and control technology and wherever wiring must be executed using the smallest possible outside diameter, with consideration of electronic possibilities, e.g. computer systems, signal technology, scales etc. \u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e24 AWG 10P HELUKABEL PAAR-TRONIC PVC cable, PAAR-TRONIC data cable, HELUKABEL industrial data cable, PVC data control cable HELUKABEL, PAAR-TRONIC twisted pair cable, HELUKABEL signal transmission cable, 24 AWG 10P HELUKABEL low voltage data cable, PAAR-TRONIC control \u0026amp; data cable, 24 AWG 10P HELUKABEL PVC shielded data cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -30°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e350 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e1200 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e2400 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003eat 800 Hz 0.14 - 0.25 mm²: approx. 100 pF\/m 0.34 - 0.75 mm²: approx. 150\u003cbr\u003epF\/m\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 300 pF\/100m\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance\u003cbr\u003e\u003c\/strong\u003e78 Ohm, (approx. value)\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003c\/strong\u003e\u003cbr\u003eapprox. 0.65 mH\/km\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 0.75 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths, Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7032)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e24 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 10 x 2 x 0.25\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 10.5\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e50.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e114.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62828922863985,"sku":"NNC19042","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1-Photoroom_2_e26ed4ae-03c6-425e-93d5-ac2f798f1c1a.png?v=1766477492"},{"product_id":"24-awg-11p-helukabel-19043-paar-tronic-pvc-data-cable","title":"24 AWG 11P Helukabel 19043 PAAR-TRONIC PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M19001_EN_GB_1.pdf?v=1766476446\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e24 AWG 11P Helukabel 19043 PAAR-TRONIC PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Used as a control and signal cable in electronic engineering, measurement and control technology and wherever wiring must be executed using the smallest possible outside diameter, with consideration of electronic possibilities, e.g. computer systems, signal technology, scales etc. \u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e24 AWG 11P HELUKABEL PAAR-TRONIC PVC cable, PAAR-TRONIC data cable, HELUKABEL industrial data cable, PVC data control cable HELUKABEL, PAAR-TRONIC twisted pair cable, HELUKABEL signal transmission cable, 24 AWG 11P HELUKABEL low voltage data cable, PAAR-TRONIC control \u0026amp; data cable, 24 AWG 11P HELUKABEL PVC shielded data cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -30°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e350 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e1200 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e2400 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003eat 800 Hz 0.14 - 0.25 mm²: approx. 100 pF\/m 0.34 - 0.75 mm²: approx. 150\u003cbr\u003epF\/m\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 300 pF\/100m\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance\u003cbr\u003e\u003c\/strong\u003e78 Ohm, (approx. value)\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003c\/strong\u003e\u003cbr\u003eapprox. 0.65 mH\/km\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 0.75 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths, Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7032)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e24 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 11 x 2 x 0.25\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 11.1\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e55.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e126.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62828924600689,"sku":"NNC19043","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1-Photoroom_2_e26ed4ae-03c6-425e-93d5-ac2f798f1c1a.png?v=1766477492"},{"product_id":"24-awg-12p-helukabel-19044-paar-tronic-pvc-data-cable","title":"24 AWG 12P Helukabel 19044 PAAR-TRONIC PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M19001_EN_GB_1.pdf?v=1766476446\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e24 AWG 12P Helukabel 19044 PAAR-TRONIC PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Used as a control and signal cable in electronic engineering, measurement and control technology and wherever wiring must be executed using the smallest possible outside diameter, with consideration of electronic possibilities, e.g. computer systems, signal technology, scales etc. \u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e24 AWG 12P HELUKABEL PAAR-TRONIC PVC cable, PAAR-TRONIC data cable, HELUKABEL industrial data cable, PVC data control cable HELUKABEL, PAAR-TRONIC twisted pair cable, HELUKABEL signal transmission cable, 24 AWG 12P HELUKABEL low voltage data cable, PAAR-TRONIC control \u0026amp; data cable, 24 AWG 12P HELUKABEL PVC shielded data cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -30°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e350 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e1200 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e2400 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003eat 800 Hz 0.14 - 0.25 mm²: approx. 100 pF\/m 0.34 - 0.75 mm²: approx. 150\u003cbr\u003epF\/m\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 300 pF\/100m\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance\u003cbr\u003e\u003c\/strong\u003e78 Ohm, (approx. value)\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003c\/strong\u003e\u003cbr\u003eapprox. 0.65 mH\/km\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 0.75 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths, Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7032)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e24 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 12 x 2 x 0.25\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 11.1\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e60.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e137.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62828934005105,"sku":"NNC19044","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1-Photoroom_2_e26ed4ae-03c6-425e-93d5-ac2f798f1c1a.png?v=1766477492"},{"product_id":"24-awg-14p-helukabel-19045-paar-tronic-pvc-data-cable","title":"24 AWG 14P Helukabel 19045 PAAR-TRONIC PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M19001_EN_GB_1.pdf?v=1766476446\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e24 AWG 14P Helukabel 19045 PAAR-TRONIC PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Used as a control and signal cable in electronic engineering, measurement and control technology and wherever wiring must be executed using the smallest possible outside diameter, with consideration of electronic possibilities, e.g. computer systems, signal technology, scales etc. \u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e24 AWG 14P HELUKABEL PAAR-TRONIC PVC cable, PAAR-TRONIC data cable, HELUKABEL industrial data cable, PVC data control cable HELUKABEL, PAAR-TRONIC twisted pair cable, HELUKABEL signal transmission cable, 24 AWG 14P HELUKABEL low voltage data cable, PAAR-TRONIC control \u0026amp; data cable, 24 AWG 14P HELUKABEL PVC shielded data cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -30°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e350 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e1200 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e2400 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003eat 800 Hz 0.14 - 0.25 mm²: approx. 100 pF\/m 0.34 - 0.75 mm²: approx. 150\u003cbr\u003epF\/m\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 300 pF\/100m\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance\u003cbr\u003e\u003c\/strong\u003e78 Ohm, (approx. value)\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003c\/strong\u003e\u003cbr\u003eapprox. 0.65 mH\/km\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 0.75 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths, Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7032)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e24 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 14 x 2 x 0.25\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 11.7\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e70.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e161.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62828934168945,"sku":"NNC19045","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1-Photoroom_2_e26ed4ae-03c6-425e-93d5-ac2f798f1c1a.png?v=1766477492"},{"product_id":"24-awg-15p-helukabel-19046-paar-tronic-pvc-data-cable","title":"24 AWG 15P Helukabel 19046 PAAR-TRONIC PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M19001_EN_GB_1.pdf?v=1766476446\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e24 AWG 15P Helukabel 19046 PAAR-TRONIC PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Used as a control and signal cable in electronic engineering, measurement and control technology and wherever wiring must be executed using the smallest possible outside diameter, with consideration of electronic possibilities, e.g. computer systems, signal technology, scales etc. \u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e24 AWG 15P HELUKABEL PAAR-TRONIC PVC cable, PAAR-TRONIC data cable, HELUKABEL industrial data cable, PVC data control cable HELUKABEL, PAAR-TRONIC twisted pair cable, HELUKABEL signal transmission cable, 24 AWG 15P HELUKABEL low voltage data cable, PAAR-TRONIC control \u0026amp; data cable, 24 AWG 15P HELUKABEL PVC shielded data cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -30°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e350 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e1200 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e2400 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003eat 800 Hz 0.14 - 0.25 mm²: approx. 100 pF\/m 0.34 - 0.75 mm²: approx. 150\u003cbr\u003epF\/m\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 300 pF\/100m\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance\u003cbr\u003e\u003c\/strong\u003e78 Ohm, (approx. value)\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003c\/strong\u003e\u003cbr\u003eapprox. 0.65 mH\/km\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 0.75 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths, Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7032)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e24 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 15 x 2 x 0.25\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 12.3\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e75.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e174.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62828934791537,"sku":"NNC19046","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1-Photoroom_2_e26ed4ae-03c6-425e-93d5-ac2f798f1c1a.png?v=1766477492"},{"product_id":"24-awg-16p-helukabel-19047-paar-tronic-pvc-data-cable","title":"24 AWG 16P Helukabel 19047 PAAR-TRONIC PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M19001_EN_GB_1.pdf?v=1766476446\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e24 AWG 16P Helukabel 19047 PAAR-TRONIC PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Used as a control and signal cable in electronic engineering, measurement and control technology and wherever wiring must be executed using the smallest possible outside diameter, with consideration of electronic possibilities, e.g. computer systems, signal technology, scales etc. \u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e24 AWG 16P HELUKABEL PAAR-TRONIC PVC cable, PAAR-TRONIC data cable, HELUKABEL industrial data cable, PVC data control cable HELUKABEL, PAAR-TRONIC twisted pair cable, HELUKABEL signal transmission cable, 24 AWG 16P HELUKABEL low voltage data cable, PAAR-TRONIC control \u0026amp; data cable, 24 AWG 16P HELUKABEL PVC shielded data cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -30°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e350 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e1200 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e2400 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003eat 800 Hz 0.14 - 0.25 mm²: approx. 100 pF\/m 0.34 - 0.75 mm²: approx. 150\u003cbr\u003epF\/m\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 300 pF\/100m\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance\u003cbr\u003e\u003c\/strong\u003e78 Ohm, (approx. value)\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003c\/strong\u003e\u003cbr\u003eapprox. 0.65 mH\/km\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 0.75 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths, Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7032)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e24 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 16 x 2 x 0.25\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 12.3\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e80.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e187.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62828935545201,"sku":"NNC19047","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1-Photoroom_2_e26ed4ae-03c6-425e-93d5-ac2f798f1c1a.png?v=1766477492"},{"product_id":"24-awg-18p-helukabel-19048-paar-tronic-pvc-data-cable","title":"24 AWG 18P Helukabel 19048 PAAR-TRONIC PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M19001_EN_GB_1.pdf?v=1766476446\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e24 AWG 18P Helukabel 19048 PAAR-TRONIC PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Used as a control and signal cable in electronic engineering, measurement and control technology and wherever wiring must be executed using the smallest possible outside diameter, with consideration of electronic possibilities, e.g. computer systems, signal technology, scales etc. \u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e24 AWG 18P HELUKABEL PAAR-TRONIC PVC cable, PAAR-TRONIC data cable, HELUKABEL industrial data cable, PVC data control cable HELUKABEL, PAAR-TRONIC twisted pair cable, HELUKABEL signal transmission cable, 24 AWG 18P HELUKABEL low voltage data cable, PAAR-TRONIC control \u0026amp; data cable, 24 AWG 18P HELUKABEL PVC shielded data cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -30°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e350 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e1200 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e2400 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003eat 800 Hz 0.14 - 0.25 mm²: approx. 100 pF\/m 0.34 - 0.75 mm²: approx. 150\u003cbr\u003epF\/m\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 300 pF\/100m\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance\u003cbr\u003e\u003c\/strong\u003e78 Ohm, (approx. value)\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003c\/strong\u003e\u003cbr\u003eapprox. 0.65 mH\/km\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 0.75 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths, Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7032)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e24 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 18 x 2 x 0.25\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 13.2\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e90.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e212.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62828940001649,"sku":"NNC19048","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1-Photoroom_2_e26ed4ae-03c6-425e-93d5-ac2f798f1c1a.png?v=1766477492"},{"product_id":"24-awg-20p-helukabel-19049-paar-tronic-pvc-data-cable","title":"24 AWG 20P Helukabel 19049 PAAR-TRONIC PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M19001_EN_GB_1.pdf?v=1766476446\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e24 AWG 20P Helukabel 19049 PAAR-TRONIC PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Used as a control and signal cable in electronic engineering, measurement and control technology and wherever wiring must be executed using the smallest possible outside diameter, with consideration of electronic possibilities, e.g. computer systems, signal technology, scales etc. \u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e24 AWG 20P HELUKABEL PAAR-TRONIC PVC cable, PAAR-TRONIC data cable, HELUKABEL industrial data cable, PVC data control cable HELUKABEL, PAAR-TRONIC twisted pair cable, HELUKABEL signal transmission cable, 24 AWG 20P HELUKABEL low voltage data cable, PAAR-TRONIC control \u0026amp; data cable, 24 AWG 20P HELUKABEL PVC shielded data cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -30°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e350 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e1200 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e2400 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003eat 800 Hz 0.14 - 0.25 mm²: approx. 100 pF\/m 0.34 - 0.75 mm²: approx. 150\u003cbr\u003epF\/m\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 300 pF\/100m\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance\u003cbr\u003e\u003c\/strong\u003e78 Ohm, (approx. value)\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003c\/strong\u003e\u003cbr\u003eapprox. 0.65 mH\/km\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 0.75 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths, Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7032)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e24 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 20 x 2 x 0.25\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 13.8\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e100.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e234.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62828942885233,"sku":"NNC19049","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1-Photoroom_2_e26ed4ae-03c6-425e-93d5-ac2f798f1c1a.png?v=1766477492"},{"product_id":"24-awg-22p-helukabel-19050-paar-tronic-pvc-data-cable","title":"24 AWG 22P Helukabel 19050 PAAR-TRONIC PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M19001_EN_GB_1.pdf?v=1766476446\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e24 AWG 22P Helukabel 19050 PAAR-TRONIC PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eSuitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Used as a control and signal cable in electronic engineering, measurement and control technology and wherever wiring must be executed using the smallest possible outside diameter, with consideration of electronic possibilities, e.g. computer systems, signal technology, scales etc. \u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e24 AWG 22P HELUKABEL PAAR-TRONIC PVC cable, PAAR-TRONIC data cable, HELUKABEL industrial data cable, PVC data control cable HELUKABEL, PAAR-TRONIC twisted pair cable, HELUKABEL signal transmission cable, 24 AWG 22P HELUKABEL low voltage data cable, PAAR-TRONIC control \u0026amp; data cable, 24 AWG 22P HELUKABEL PVC shielded data cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -30°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e350 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e1200 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e2400 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003eat 800 Hz 0.14 - 0.25 mm²: approx. 100 pF\/m 0.34 - 0.75 mm²: approx. 150\u003cbr\u003epF\/m\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 300 pF\/100m\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharacteristic impedance\u003cbr\u003e\u003c\/strong\u003e78 Ohm, (approx. value)\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductance\u003c\/strong\u003e\u003cbr\u003eapprox. 0.65 mH\/km\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 7.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 - 0.75 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths, Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7032)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e24 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 22 x 2 x 0.25 \u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 15.6\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e110.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e250.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62828943475057,"sku":"NNC19050","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1-Photoroom_2_e26ed4ae-03c6-425e-93d5-ac2f798f1c1a.png?v=1766477492"}],"url":"https:\/\/nassaunationalcable.com\/collections\/helukabel-paar-tronic-pvc-data-cable.oembed?page=2","provider":"NassauNationalCable","version":"1.0","type":"link"}