{"title":"HELUKABEL PAAR-TRONIC-CY-CY PVC DATA CABLE","description":"","products":[{"product_id":"26-awg-2p-helukabel-21065-paar-tronic-cy-cy-pvc-data-cable","title":"26 AWG 2P Helukabel 21065 PAAR-TRONIC-CY-CY PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M21065_EN_GB_1.pdf?v=1767676312\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 2P Helukabel 21065 PAAR-TRONIC-CY-CY PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a control and signal cable in electronic engineering, measurement and control technology. It provides interference-free transmission of data signals from peripheral equipment to information storage. Excellent connection cable for sound mixers, studio equipment and measurement and control technology. Reliable in process control, machining centers and safety-related systems. These cables with copper screening are ideally suited for interefence-free data and signal transmission for measurement and control technology. EMC = Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 2P Helukabel Paar Tronic CY CY cable, PAAR-TRONIC-CY-CY data cable, Helukabel shielded data cable, Helukabel CY-CY control cable, PVC screened data cable Helukabel, Helukabel instrumentation cable, 26 AWG 2P Pair-screened PVC data cable, Helukabel EMC data cable, Helukabel flexible data cable, 26 AWG 2P Helukabel signal control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 350 V 0.25 - 0.5 mm²: 500 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 1200 V\u003cbr\u003e0.25 - 0.5 mm²: 2000 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e800 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 2400 V\u003cbr\u003e0.25 - 0.5 mm²: 4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003e\u003c\/span\u003eat 800 Hz 0.14 mm²: approx. 147 pF\/m 0.25 mm²: approx. 152 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/screen\u003cbr\u003e\u003c\/strong\u003eat 800 Hz 0.14 mm²: approx. 220 pF\/m 0.25 mm²: approx. 263 pF\/m\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 250 pF\/100m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance \u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12x Outer-Ø\u003cbr\u003efixed 6x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths\u003cbr\u003e• Screening element: pairs, braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• PVC sheath over each screened pair\u003cbr\u003e• Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e26 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 2 x 2 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 8.3\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e31.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e95.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62876010774897,"sku":"NNC21065","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_bf00a8a6-fc2f-4b0a-abf6-91bfda7c3114.png?v=1767676691"},{"product_id":"26-awg-3p-helukabel-21066-paar-tronic-cy-cy-pvc-data-cable","title":"26 AWG 3P Helukabel 21066 PAAR-TRONIC-CY-CY PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M21065_EN_GB_1.pdf?v=1767676312\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 3P Helukabel 21066 PAAR-TRONIC-CY-CY PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a control and signal cable in electronic engineering, measurement and control technology. It provides interference-free transmission of data signals from peripheral equipment to information storage. Excellent connection cable for sound mixers, studio equipment and measurement and control technology. Reliable in process control, machining centers and safety-related systems. These cables with copper screening are ideally suited for interefence-free data and signal transmission for measurement and control technology. EMC = Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 3P Helukabel Paar Tronic CY CY cable, PAAR-TRONIC-CY-CY data cable, Helukabel shielded data cable, Helukabel CY-CY control cable, PVC screened data cable Helukabel, Helukabel instrumentation cable, 26 AWG 3P Pair-screened PVC data cable, Helukabel EMC data cable, Helukabel flexible data cable, 26 AWG 3P Helukabel signal control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 350 V 0.25 - 0.5 mm²: 500 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 1200 V\u003cbr\u003e0.25 - 0.5 mm²: 2000 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e800 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 2400 V\u003cbr\u003e0.25 - 0.5 mm²: 4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003e\u003c\/span\u003eat 800 Hz 0.14 mm²: approx. 147 pF\/m 0.25 mm²: approx. 152 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/screen\u003cbr\u003e\u003c\/strong\u003eat 800 Hz 0.14 mm²: approx. 220 pF\/m 0.25 mm²: approx. 263 pF\/m\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 250 pF\/100m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance \u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12x Outer-Ø\u003cbr\u003efixed 6x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths\u003cbr\u003e• Screening element: pairs, braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• PVC sheath over each screened pair\u003cbr\u003e• Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e26 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 3 x 2 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 9.2\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e34.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e105.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62876397863281,"sku":"NNC21066","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_bf00a8a6-fc2f-4b0a-abf6-91bfda7c3114.png?v=1767676691"},{"product_id":"26-awg-4p-helukabel-21067-paar-tronic-cy-cy-pvc-data-cable","title":"26 AWG 4P Helukabel 21067 PAAR-TRONIC-CY-CY PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M21065_EN_GB_1.pdf?v=1767676312\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 4P Helukabel 21067 PAAR-TRONIC-CY-CY PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a control and signal cable in electronic engineering, measurement and control technology. It provides interference-free transmission of data signals from peripheral equipment to information storage. Excellent connection cable for sound mixers, studio equipment and measurement and control technology. Reliable in process control, machining centers and safety-related systems. These cables with copper screening are ideally suited for interefence-free data and signal transmission for measurement and control technology. EMC = Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 4P Helukabel Paar Tronic CY CY cable, PAAR-TRONIC-CY-CY data cable, Helukabel shielded data cable, Helukabel CY-CY control cable, PVC screened data cable Helukabel, Helukabel instrumentation cable, 26 AWG 4P Pair-screened PVC data cable, Helukabel EMC data cable, Helukabel flexible data cable, 26 AWG 4P Helukabel signal control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 350 V 0.25 - 0.5 mm²: 500 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 1200 V\u003cbr\u003e0.25 - 0.5 mm²: 2000 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e800 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 2400 V\u003cbr\u003e0.25 - 0.5 mm²: 4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003e\u003c\/span\u003eat 800 Hz 0.14 mm²: approx. 147 pF\/m 0.25 mm²: approx. 152 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/screen\u003cbr\u003e\u003c\/strong\u003eat 800 Hz 0.14 mm²: approx. 220 pF\/m 0.25 mm²: approx. 263 pF\/m\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 250 pF\/100m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance \u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12x Outer-Ø\u003cbr\u003efixed 6x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths\u003cbr\u003e• Screening element: pairs, braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• PVC sheath over each screened pair\u003cbr\u003e• Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e26 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 4 x 2 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 10.2\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e45.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e140.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62876413722993,"sku":"NNC21067","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_bf00a8a6-fc2f-4b0a-abf6-91bfda7c3114.png?v=1767676691"},{"product_id":"26-awg-5p-helukabel-21068-paar-tronic-cy-cy-pvc-data-cable","title":"26 AWG 5P Helukabel 21068 PAAR-TRONIC-CY-CY PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M21065_EN_GB_1.pdf?v=1767676312\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 5P Helukabel 21068 PAAR-TRONIC-CY-CY PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a control and signal cable in electronic engineering, measurement and control technology. It provides interference-free transmission of data signals from peripheral equipment to information storage. Excellent connection cable for sound mixers, studio equipment and measurement and control technology. Reliable in process control, machining centers and safety-related systems. These cables with copper screening are ideally suited for interefence-free data and signal transmission for measurement and control technology. EMC = Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 5P Helukabel Paar Tronic CY CY cable, PAAR-TRONIC-CY-CY data cable, Helukabel shielded data cable, Helukabel CY-CY control cable, PVC screened data cable Helukabel, Helukabel instrumentation cable, 26 AWG 5P Pair-screened PVC data cable, Helukabel EMC data cable, Helukabel flexible data cable, 26 AWG 5P Helukabel signal control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 350 V 0.25 - 0.5 mm²: 500 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 1200 V\u003cbr\u003e0.25 - 0.5 mm²: 2000 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e800 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 2400 V\u003cbr\u003e0.25 - 0.5 mm²: 4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003e\u003c\/span\u003eat 800 Hz 0.14 mm²: approx. 147 pF\/m 0.25 mm²: approx. 152 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/screen\u003cbr\u003e\u003c\/strong\u003eat 800 Hz 0.14 mm²: approx. 220 pF\/m 0.25 mm²: approx. 263 pF\/m\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 250 pF\/100m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance \u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12x Outer-Ø\u003cbr\u003efixed 6x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths\u003cbr\u003e• Screening element: pairs, braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• PVC sheath over each screened pair\u003cbr\u003e• Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e26 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 5 x 2 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 11.1\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e58.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e160.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62876428927345,"sku":"NNC21068","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_bf00a8a6-fc2f-4b0a-abf6-91bfda7c3114.png?v=1767676691"},{"product_id":"26-awg-6p-helukabel-21069-paar-tronic-cy-cy-pvc-data-cable","title":"26 AWG 6P Helukabel 21069 PAAR-TRONIC-CY-CY PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M21065_EN_GB_1.pdf?v=1767676312\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 6P Helukabel 21069 PAAR-TRONIC-CY-CY PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a control and signal cable in electronic engineering, measurement and control technology. It provides interference-free transmission of data signals from peripheral equipment to information storage. Excellent connection cable for sound mixers, studio equipment and measurement and control technology. Reliable in process control, machining centers and safety-related systems. These cables with copper screening are ideally suited for interefence-free data and signal transmission for measurement and control technology. EMC = Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 6P Helukabel Paar Tronic CY CY cable, PAAR-TRONIC-CY-CY data cable, Helukabel shielded data cable, Helukabel CY-CY control cable, PVC screened data cable Helukabel, Helukabel instrumentation cable, 26 AWG 6P Pair-screened PVC data cable, Helukabel EMC data cable, Helukabel flexible data cable, 26 AWG 6P Helukabel signal control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 350 V 0.25 - 0.5 mm²: 500 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 1200 V\u003cbr\u003e0.25 - 0.5 mm²: 2000 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e800 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 2400 V\u003cbr\u003e0.25 - 0.5 mm²: 4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003e\u003c\/span\u003eat 800 Hz 0.14 mm²: approx. 147 pF\/m 0.25 mm²: approx. 152 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/screen\u003cbr\u003e\u003c\/strong\u003eat 800 Hz 0.14 mm²: approx. 220 pF\/m 0.25 mm²: approx. 263 pF\/m\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 250 pF\/100m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance \u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12x Outer-Ø\u003cbr\u003efixed 6x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths\u003cbr\u003e• Screening element: pairs, braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• PVC sheath over each screened pair\u003cbr\u003e• Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e26 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 6 x 2 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 12.3\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e67.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e185.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62876443804017,"sku":"NNC21069","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_bf00a8a6-fc2f-4b0a-abf6-91bfda7c3114.png?v=1767676691"},{"product_id":"26-awg-7p-helukabel-21070-paar-tronic-cy-cy-pvc-data-cable","title":"26 AWG 7P Helukabel 21070 PAAR-TRONIC-CY-CY PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M21065_EN_GB_1.pdf?v=1767676312\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 7P Helukabel 21070 PAAR-TRONIC-CY-CY PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a control and signal cable in electronic engineering, measurement and control technology. It provides interference-free transmission of data signals from peripheral equipment to information storage. Excellent connection cable for sound mixers, studio equipment and measurement and control technology. Reliable in process control, machining centers and safety-related systems. These cables with copper screening are ideally suited for interefence-free data and signal transmission for measurement and control technology. EMC = Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 7P Helukabel Paar Tronic CY CY cable, PAAR-TRONIC-CY-CY data cable, Helukabel shielded data cable, Helukabel CY-CY control cable, PVC screened data cable Helukabel, Helukabel instrumentation cable, 26 AWG 7P Pair-screened PVC data cable, Helukabel EMC data cable, Helukabel flexible data cable, 26 AWG 7P Helukabel signal control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 350 V 0.25 - 0.5 mm²: 500 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 1200 V\u003cbr\u003e0.25 - 0.5 mm²: 2000 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e800 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 2400 V\u003cbr\u003e0.25 - 0.5 mm²: 4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003e\u003c\/span\u003eat 800 Hz 0.14 mm²: approx. 147 pF\/m 0.25 mm²: approx. 152 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/screen\u003cbr\u003e\u003c\/strong\u003eat 800 Hz 0.14 mm²: approx. 220 pF\/m 0.25 mm²: approx. 263 pF\/m\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 250 pF\/100m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance \u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12x Outer-Ø\u003cbr\u003efixed 6x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths\u003cbr\u003e• Screening element: pairs, braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• PVC sheath over each screened pair\u003cbr\u003e• Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e26 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 7 x 2 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 12.3\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e78.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e230.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62876460188017,"sku":"NNC21070","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_bf00a8a6-fc2f-4b0a-abf6-91bfda7c3114.png?v=1767676691"},{"product_id":"26-awg-8p-helukabel-21071-paar-tronic-cy-cy-pvc-data-cable","title":"26 AWG 8P Helukabel 21071 PAAR-TRONIC-CY-CY PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M21065_EN_GB_1.pdf?v=1767676312\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 8P Helukabel 21071 PAAR-TRONIC-CY-CY PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a control and signal cable in electronic engineering, measurement and control technology. It provides interference-free transmission of data signals from peripheral equipment to information storage. Excellent connection cable for sound mixers, studio equipment and measurement and control technology. Reliable in process control, machining centers and safety-related systems. These cables with copper screening are ideally suited for interefence-free data and signal transmission for measurement and control technology. EMC = Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 8P Helukabel Paar Tronic CY CY cable, PAAR-TRONIC-CY-CY data cable, Helukabel shielded data cable, Helukabel CY-CY control cable, PVC screened data cable Helukabel, Helukabel instrumentation cable, 26 AWG 8P Pair-screened PVC data cable, Helukabel EMC data cable, Helukabel flexible data cable, 26 AWG 8P Helukabel signal control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 350 V 0.25 - 0.5 mm²: 500 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 1200 V\u003cbr\u003e0.25 - 0.5 mm²: 2000 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e800 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 2400 V\u003cbr\u003e0.25 - 0.5 mm²: 4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003e\u003c\/span\u003eat 800 Hz 0.14 mm²: approx. 147 pF\/m 0.25 mm²: approx. 152 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/screen\u003cbr\u003e\u003c\/strong\u003eat 800 Hz 0.14 mm²: approx. 220 pF\/m 0.25 mm²: approx. 263 pF\/m\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 250 pF\/100m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance \u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12x Outer-Ø\u003cbr\u003efixed 6x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths\u003cbr\u003e• Screening element: pairs, braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• PVC sheath over each screened pair\u003cbr\u003e• Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e26 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 8 x 2 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 14.6\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e97.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e245.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62876475851121,"sku":"NNC21071","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_bf00a8a6-fc2f-4b0a-abf6-91bfda7c3114.png?v=1767676691"},{"product_id":"26-awg-9p-helukabel-21072-paar-tronic-cy-cy-pvc-data-cable","title":"26 AWG 9P Helukabel 21072 PAAR-TRONIC-CY-CY PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M21065_EN_GB_1.pdf?v=1767676312\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 9P Helukabel 21072 PAAR-TRONIC-CY-CY PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a control and signal cable in electronic engineering, measurement and control technology. It provides interference-free transmission of data signals from peripheral equipment to information storage. Excellent connection cable for sound mixers, studio equipment and measurement and control technology. Reliable in process control, machining centers and safety-related systems. These cables with copper screening are ideally suited for interefence-free data and signal transmission for measurement and control technology. EMC = Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 9P Helukabel Paar Tronic CY CY cable, PAAR-TRONIC-CY-CY data cable, Helukabel shielded data cable, Helukabel CY-CY control cable, PVC screened data cable Helukabel, Helukabel instrumentation cable, 26 AWG 9P Pair-screened PVC data cable, Helukabel EMC data cable, Helukabel flexible data cable, 26 AWG 9P Helukabel signal control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 350 V 0.25 - 0.5 mm²: 500 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 1200 V\u003cbr\u003e0.25 - 0.5 mm²: 2000 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e800 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 2400 V\u003cbr\u003e0.25 - 0.5 mm²: 4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003e\u003c\/span\u003eat 800 Hz 0.14 mm²: approx. 147 pF\/m 0.25 mm²: approx. 152 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/screen\u003cbr\u003e\u003c\/strong\u003eat 800 Hz 0.14 mm²: approx. 220 pF\/m 0.25 mm²: approx. 263 pF\/m\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 250 pF\/100m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance \u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12x Outer-Ø\u003cbr\u003efixed 6x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths\u003cbr\u003e• Screening element: pairs, braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• PVC sheath over each screened pair\u003cbr\u003e• Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e26 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 9 x 2 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 15.8\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e101.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e280.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62876487975281,"sku":"NNC21072","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_bf00a8a6-fc2f-4b0a-abf6-91bfda7c3114.png?v=1767676691"},{"product_id":"26-awg-10p-helukabel-21073-paar-tronic-cy-cy-pvc-data-cable","title":"26 AWG 10P Helukabel 21073 PAAR-TRONIC-CY-CY PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M21065_EN_GB_1.pdf?v=1767676312\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 10P Helukabel 21073 PAAR-TRONIC-CY-CY PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a control and signal cable in electronic engineering, measurement and control technology. It provides interference-free transmission of data signals from peripheral equipment to information storage. Excellent connection cable for sound mixers, studio equipment and measurement and control technology. Reliable in process control, machining centers and safety-related systems. These cables with copper screening are ideally suited for interefence-free data and signal transmission for measurement and control technology. EMC = Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 10P Helukabel Paar Tronic CY CY cable, PAAR-TRONIC-CY-CY data cable, Helukabel shielded data cable, Helukabel CY-CY control cable, PVC screened data cable Helukabel, Helukabel instrumentation cable, 26 AWG 10P Pair-screened PVC data cable, Helukabel EMC data cable, Helukabel flexible data cable, 26 AWG 10P Helukabel signal control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 350 V 0.25 - 0.5 mm²: 500 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 1200 V\u003cbr\u003e0.25 - 0.5 mm²: 2000 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e800 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 2400 V\u003cbr\u003e0.25 - 0.5 mm²: 4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003e\u003c\/span\u003eat 800 Hz 0.14 mm²: approx. 147 pF\/m 0.25 mm²: approx. 152 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/screen\u003cbr\u003e\u003c\/strong\u003eat 800 Hz 0.14 mm²: approx. 220 pF\/m 0.25 mm²: approx. 263 pF\/m\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 250 pF\/100m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance \u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12x Outer-Ø\u003cbr\u003efixed 6x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths\u003cbr\u003e• Screening element: pairs, braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• PVC sheath over each screened pair\u003cbr\u003e• Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e26 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 10 x 2 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 16.0\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e108.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e325.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62876502524273,"sku":"NNC21073","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_bf00a8a6-fc2f-4b0a-abf6-91bfda7c3114.png?v=1767676691"},{"product_id":"26-awg-12p-helukabel-21074-paar-tronic-cy-cy-pvc-data-cable","title":"26 AWG 12P Helukabel 21074 PAAR-TRONIC-CY-CY PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M21065_EN_GB_1.pdf?v=1767676312\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 12P Helukabel 21074 PAAR-TRONIC-CY-CY PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a control and signal cable in electronic engineering, measurement and control technology. It provides interference-free transmission of data signals from peripheral equipment to information storage. Excellent connection cable for sound mixers, studio equipment and measurement and control technology. Reliable in process control, machining centers and safety-related systems. These cables with copper screening are ideally suited for interefence-free data and signal transmission for measurement and control technology. EMC = Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 12P Helukabel Paar Tronic CY CY cable, PAAR-TRONIC-CY-CY data cable, Helukabel shielded data cable, Helukabel CY-CY control cable, PVC screened data cable Helukabel, Helukabel instrumentation cable, 26 AWG 12P Pair-screened PVC data cable, Helukabel EMC data cable, Helukabel flexible data cable, 26 AWG 12P Helukabel signal control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 350 V 0.25 - 0.5 mm²: 500 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 1200 V\u003cbr\u003e0.25 - 0.5 mm²: 2000 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e800 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 2400 V\u003cbr\u003e0.25 - 0.5 mm²: 4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003e\u003c\/span\u003eat 800 Hz 0.14 mm²: approx. 147 pF\/m 0.25 mm²: approx. 152 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/screen\u003cbr\u003e\u003c\/strong\u003eat 800 Hz 0.14 mm²: approx. 220 pF\/m 0.25 mm²: approx. 263 pF\/m\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 250 pF\/100m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance \u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12x Outer-Ø\u003cbr\u003efixed 6x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths\u003cbr\u003e• Screening element: pairs, braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• PVC sheath over each screened pair\u003cbr\u003e• Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e26 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 12 x 2 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 16.7\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e134.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e380.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62876512944497,"sku":"NNC21074","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_bf00a8a6-fc2f-4b0a-abf6-91bfda7c3114.png?v=1767676691"},{"product_id":"26-awg-16p-helukabel-21075-paar-tronic-cy-cy-pvc-data-cable","title":"26 AWG 16P Helukabel 21075 PAAR-TRONIC-CY-CY PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M21065_EN_GB_1.pdf?v=1767676312\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 16P Helukabel 21075 PAAR-TRONIC-CY-CY PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a control and signal cable in electronic engineering, measurement and control technology. It provides interference-free transmission of data signals from peripheral equipment to information storage. Excellent connection cable for sound mixers, studio equipment and measurement and control technology. Reliable in process control, machining centers and safety-related systems. These cables with copper screening are ideally suited for interefence-free data and signal transmission for measurement and control technology. EMC = Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 16P Helukabel Paar Tronic CY CY cable, PAAR-TRONIC-CY-CY data cable, Helukabel shielded data cable, Helukabel CY-CY control cable, PVC screened data cable Helukabel, Helukabel instrumentation cable, 26 AWG 16P Pair-screened PVC data cable, Helukabel EMC data cable, Helukabel flexible data cable, 26 AWG 16P Helukabel signal control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 350 V 0.25 - 0.5 mm²: 500 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 1200 V\u003cbr\u003e0.25 - 0.5 mm²: 2000 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e800 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 2400 V\u003cbr\u003e0.25 - 0.5 mm²: 4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003e\u003c\/span\u003eat 800 Hz 0.14 mm²: approx. 147 pF\/m 0.25 mm²: approx. 152 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/screen\u003cbr\u003e\u003c\/strong\u003eat 800 Hz 0.14 mm²: approx. 220 pF\/m 0.25 mm²: approx. 263 pF\/m\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 250 pF\/100m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance \u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12x Outer-Ø\u003cbr\u003efixed 6x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths\u003cbr\u003e• Screening element: pairs, braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• PVC sheath over each screened pair\u003cbr\u003e• Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e26 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 16 x 2 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 18.6\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e179.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e440.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62876533850481,"sku":"NNC21075","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_bf00a8a6-fc2f-4b0a-abf6-91bfda7c3114.png?v=1767676691"},{"product_id":"26-awg-20p-helukabel-21076-paar-tronic-cy-cy-pvc-data-cable","title":"26 AWG 20P Helukabel 21076 PAAR-TRONIC-CY-CY PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M21065_EN_GB_1.pdf?v=1767676312\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e26 AWG 20P Helukabel 21076 PAAR-TRONIC-CY-CY PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a control and signal cable in electronic engineering, measurement and control technology. It provides interference-free transmission of data signals from peripheral equipment to information storage. Excellent connection cable for sound mixers, studio equipment and measurement and control technology. Reliable in process control, machining centers and safety-related systems. These cables with copper screening are ideally suited for interefence-free data and signal transmission for measurement and control technology. EMC = Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e26 AWG 20P Helukabel Paar Tronic CY CY cable, PAAR-TRONIC-CY-CY data cable, Helukabel shielded data cable, Helukabel CY-CY control cable, PVC screened data cable Helukabel, Helukabel instrumentation cable, 26 AWG 20P Pair-screened PVC data cable, Helukabel EMC data cable, Helukabel flexible data cable, 26 AWG 20P Helukabel signal control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 350 V 0.25 - 0.5 mm²: 500 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 1200 V\u003cbr\u003e0.25 - 0.5 mm²: 2000 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e800 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 2400 V\u003cbr\u003e0.25 - 0.5 mm²: 4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003e\u003c\/span\u003eat 800 Hz 0.14 mm²: approx. 147 pF\/m 0.25 mm²: approx. 152 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/screen\u003cbr\u003e\u003c\/strong\u003eat 800 Hz 0.14 mm²: approx. 220 pF\/m 0.25 mm²: approx. 263 pF\/m\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 250 pF\/100m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance \u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12x Outer-Ø\u003cbr\u003efixed 6x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths\u003cbr\u003e• Screening element: pairs, braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• PVC sheath over each screened pair\u003cbr\u003e• Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e26 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 20 x 2 x 0.14\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 21.0\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e225.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e520.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62876550857073,"sku":"NNC21076","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_bf00a8a6-fc2f-4b0a-abf6-91bfda7c3114.png?v=1767676691"},{"product_id":"24-awg-2p-helukabel-21077-paar-tronic-cy-cy-pvc-data-cable","title":"24 AWG 2P Helukabel 21077 PAAR-TRONIC-CY-CY PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M21065_EN_GB_1.pdf?v=1767676312\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e24 AWG 2P Helukabel 21077 PAAR-TRONIC-CY-CY PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a control and signal cable in electronic engineering, measurement and control technology. It provides interference-free transmission of data signals from peripheral equipment to information storage. Excellent connection cable for sound mixers, studio equipment and measurement and control technology. Reliable in process control, machining centers and safety-related systems. These cables with copper screening are ideally suited for interefence-free data and signal transmission for measurement and control technology. EMC = Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e24 AWG 2P Helukabel Paar Tronic CY CY cable, PAAR-TRONIC-CY-CY data cable, Helukabel shielded data cable, Helukabel CY-CY control cable, PVC screened data cable Helukabel, Helukabel instrumentation cable, 24 AWG 2P Pair-screened PVC data cable, Helukabel EMC data cable, Helukabel flexible data cable, 24 AWG 2P Helukabel signal control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 350 V 0.25 - 0.5 mm²: 500 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 1200 V\u003cbr\u003e0.25 - 0.5 mm²: 2000 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e800 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 2400 V\u003cbr\u003e0.25 - 0.5 mm²: 4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003e\u003c\/span\u003eat 800 Hz 0.14 mm²: approx. 147 pF\/m 0.25 mm²: approx. 152 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/screen\u003cbr\u003e\u003c\/strong\u003eat 800 Hz 0.14 mm²: approx. 220 pF\/m 0.25 mm²: approx. 263 pF\/m\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 250 pF\/100m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance \u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12x Outer-Ø\u003cbr\u003efixed 6x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths\u003cbr\u003e• Screening element: pairs, braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• PVC sheath over each screened pair\u003cbr\u003e• Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e24 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 2 x 2 x 0.25\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 9.5\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e62.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e125.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62876569370993,"sku":"NNC21077","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_bf00a8a6-fc2f-4b0a-abf6-91bfda7c3114.png?v=1767676691"},{"product_id":"24-awg-3p-helukabel-21078-paar-tronic-cy-cy-pvc-data-cable","title":"24 AWG 3P Helukabel 21078 PAAR-TRONIC-CY-CY PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M21065_EN_GB_1.pdf?v=1767676312\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e24 AWG 3P Helukabel 21078 PAAR-TRONIC-CY-CY PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a control and signal cable in electronic engineering, measurement and control technology. It provides interference-free transmission of data signals from peripheral equipment to information storage. Excellent connection cable for sound mixers, studio equipment and measurement and control technology. Reliable in process control, machining centers and safety-related systems. These cables with copper screening are ideally suited for interefence-free data and signal transmission for measurement and control technology. EMC = Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e24 AWG 3P Helukabel Paar Tronic CY CY cable, PAAR-TRONIC-CY-CY data cable, Helukabel shielded data cable, Helukabel CY-CY control cable, PVC screened data cable Helukabel, Helukabel instrumentation cable, 24 AWG 3P Pair-screened PVC data cable, Helukabel EMC data cable, Helukabel flexible data cable, 24 AWG 3P Helukabel signal control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 350 V 0.25 - 0.5 mm²: 500 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 1200 V\u003cbr\u003e0.25 - 0.5 mm²: 2000 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e800 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 2400 V\u003cbr\u003e0.25 - 0.5 mm²: 4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003e\u003c\/span\u003eat 800 Hz 0.14 mm²: approx. 147 pF\/m 0.25 mm²: approx. 152 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/screen\u003cbr\u003e\u003c\/strong\u003eat 800 Hz 0.14 mm²: approx. 220 pF\/m 0.25 mm²: approx. 263 pF\/m\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 250 pF\/100m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance \u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12x Outer-Ø\u003cbr\u003efixed 6x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths\u003cbr\u003e• Screening element: pairs, braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• PVC sheath over each screened pair\u003cbr\u003e• Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e24 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 3 x 2 x 0.25\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 10.6\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e78.2\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e140.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62876579823985,"sku":"NNC21078","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_bf00a8a6-fc2f-4b0a-abf6-91bfda7c3114.png?v=1767676691"},{"product_id":"24-awg-4p-helukabel-21079-paar-tronic-cy-cy-pvc-data-cable","title":"24 AWG 4P Helukabel 21079 PAAR-TRONIC-CY-CY PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M21065_EN_GB_1.pdf?v=1767676312\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e24 AWG 4P Helukabel 21079 PAAR-TRONIC-CY-CY PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a control and signal cable in electronic engineering, measurement and control technology. It provides interference-free transmission of data signals from peripheral equipment to information storage. Excellent connection cable for sound mixers, studio equipment and measurement and control technology. Reliable in process control, machining centers and safety-related systems. These cables with copper screening are ideally suited for interefence-free data and signal transmission for measurement and control technology. EMC = Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e24 AWG 4P Helukabel Paar Tronic CY CY cable, PAAR-TRONIC-CY-CY data cable, Helukabel shielded data cable, Helukabel CY-CY control cable, PVC screened data cable Helukabel, Helukabel instrumentation cable, 24 AWG 4P Pair-screened PVC data cable, Helukabel EMC data cable, Helukabel flexible data cable, 24 AWG 4P Helukabel signal control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 350 V 0.25 - 0.5 mm²: 500 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 1200 V\u003cbr\u003e0.25 - 0.5 mm²: 2000 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e800 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 2400 V\u003cbr\u003e0.25 - 0.5 mm²: 4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003e\u003c\/span\u003eat 800 Hz 0.14 mm²: approx. 147 pF\/m 0.25 mm²: approx. 152 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/screen\u003cbr\u003e\u003c\/strong\u003eat 800 Hz 0.14 mm²: approx. 220 pF\/m 0.25 mm²: approx. 263 pF\/m\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 250 pF\/100m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance \u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12x Outer-Ø\u003cbr\u003efixed 6x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths\u003cbr\u003e• Screening element: pairs, braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• PVC sheath over each screened pair\u003cbr\u003e• Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e24 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 4 x 2 x 0.25\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 11.5\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e124.1\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e205.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62876605415793,"sku":"NNC21079","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_bf00a8a6-fc2f-4b0a-abf6-91bfda7c3114.png?v=1767676691"},{"product_id":"24-awg-5p-helukabel-21080-paar-tronic-cy-cy-pvc-data-cable","title":"24 AWG 5P Helukabel 21080 PAAR-TRONIC-CY-CY PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M21065_EN_GB_1.pdf?v=1767676312\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e24 AWG 5P Helukabel 21080 PAAR-TRONIC-CY-CY PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a control and signal cable in electronic engineering, measurement and control technology. It provides interference-free transmission of data signals from peripheral equipment to information storage. Excellent connection cable for sound mixers, studio equipment and measurement and control technology. Reliable in process control, machining centers and safety-related systems. These cables with copper screening are ideally suited for interefence-free data and signal transmission for measurement and control technology. EMC = Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e24 AWG 5P Helukabel Paar Tronic CY CY cable, PAAR-TRONIC-CY-CY data cable, Helukabel shielded data cable, Helukabel CY-CY control cable, PVC screened data cable Helukabel, Helukabel instrumentation cable, 24 AWG 5P Pair-screened PVC data cable, Helukabel EMC data cable, Helukabel flexible data cable, 24 AWG 5P Helukabel signal control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 350 V 0.25 - 0.5 mm²: 500 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 1200 V\u003cbr\u003e0.25 - 0.5 mm²: 2000 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e800 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 2400 V\u003cbr\u003e0.25 - 0.5 mm²: 4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003e\u003c\/span\u003eat 800 Hz 0.14 mm²: approx. 147 pF\/m 0.25 mm²: approx. 152 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/screen\u003cbr\u003e\u003c\/strong\u003eat 800 Hz 0.14 mm²: approx. 220 pF\/m 0.25 mm²: approx. 263 pF\/m\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 250 pF\/100m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance \u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12x Outer-Ø\u003cbr\u003efixed 6x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths\u003cbr\u003e• Screening element: pairs, braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• PVC sheath over each screened pair\u003cbr\u003e• Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e24 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 5 x 2 x 0.25\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 13.0\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e137.6\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e230.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62876622487921,"sku":"NNC21080","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_bf00a8a6-fc2f-4b0a-abf6-91bfda7c3114.png?v=1767676691"},{"product_id":"24-awg-6p-helukabel-21081-paar-tronic-cy-cy-pvc-data-cable","title":"24 AWG 6P Helukabel 21081 PAAR-TRONIC-CY-CY PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M21065_EN_GB_1.pdf?v=1767676312\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e24 AWG 6P Helukabel 21081 PAAR-TRONIC-CY-CY PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a control and signal cable in electronic engineering, measurement and control technology. It provides interference-free transmission of data signals from peripheral equipment to information storage. Excellent connection cable for sound mixers, studio equipment and measurement and control technology. Reliable in process control, machining centers and safety-related systems. These cables with copper screening are ideally suited for interefence-free data and signal transmission for measurement and control technology. EMC = Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e24 AWG 6P Helukabel Paar Tronic CY CY cable, PAAR-TRONIC-CY-CY data cable, Helukabel shielded data cable, Helukabel CY-CY control cable, PVC screened data cable Helukabel, Helukabel instrumentation cable, 24 AWG 6P Pair-screened PVC data cable, Helukabel EMC data cable, Helukabel flexible data cable, 24 AWG 6P Helukabel signal control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 350 V 0.25 - 0.5 mm²: 500 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 1200 V\u003cbr\u003e0.25 - 0.5 mm²: 2000 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e800 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 2400 V\u003cbr\u003e0.25 - 0.5 mm²: 4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003e\u003c\/span\u003eat 800 Hz 0.14 mm²: approx. 147 pF\/m 0.25 mm²: approx. 152 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/screen\u003cbr\u003e\u003c\/strong\u003eat 800 Hz 0.14 mm²: approx. 220 pF\/m 0.25 mm²: approx. 263 pF\/m\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 250 pF\/100m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance \u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12x Outer-Ø\u003cbr\u003efixed 6x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths\u003cbr\u003e• Screening element: pairs, braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• PVC sheath over each screened pair\u003cbr\u003e• Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e24 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 6 x 2 x 0.25\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 14.3\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e148.1\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e275.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62876641132913,"sku":"NNC21081","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_bf00a8a6-fc2f-4b0a-abf6-91bfda7c3114.png?v=1767676691"},{"product_id":"24-awg-7p-helukabel-21082-paar-tronic-cy-cy-pvc-data-cable","title":"24 AWG 7P Helukabel 21082 PAAR-TRONIC-CY-CY PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M21065_EN_GB_1.pdf?v=1767676312\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e24 AWG 7P Helukabel 21082 PAAR-TRONIC-CY-CY PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a control and signal cable in electronic engineering, measurement and control technology. It provides interference-free transmission of data signals from peripheral equipment to information storage. Excellent connection cable for sound mixers, studio equipment and measurement and control technology. Reliable in process control, machining centers and safety-related systems. These cables with copper screening are ideally suited for interefence-free data and signal transmission for measurement and control technology. EMC = Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e24 AWG 7P Helukabel Paar Tronic CY CY cable, PAAR-TRONIC-CY-CY data cable, Helukabel shielded data cable, Helukabel CY-CY control cable, PVC screened data cable Helukabel, Helukabel instrumentation cable, 24 AWG 7P Pair-screened PVC data cable, Helukabel EMC data cable, Helukabel flexible data cable, 24 AWG 7P Helukabel signal control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 350 V 0.25 - 0.5 mm²: 500 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 1200 V\u003cbr\u003e0.25 - 0.5 mm²: 2000 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e800 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 2400 V\u003cbr\u003e0.25 - 0.5 mm²: 4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003e\u003c\/span\u003eat 800 Hz 0.14 mm²: approx. 147 pF\/m 0.25 mm²: approx. 152 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/screen\u003cbr\u003e\u003c\/strong\u003eat 800 Hz 0.14 mm²: approx. 220 pF\/m 0.25 mm²: approx. 263 pF\/m\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 250 pF\/100m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance \u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12x Outer-Ø\u003cbr\u003efixed 6x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths\u003cbr\u003e• Screening element: pairs, braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• PVC sheath over each screened pair\u003cbr\u003e• Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e24 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 7 x 2 x 0.25\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 14.3\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e159.1\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e295.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62876662432113,"sku":"NNC21082","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_bf00a8a6-fc2f-4b0a-abf6-91bfda7c3114.png?v=1767676691"},{"product_id":"24-awg-8p-helukabel-21083-paar-tronic-cy-cy-pvc-data-cable","title":"24 AWG 8P Helukabel 21083 PAAR-TRONIC-CY-CY PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M21065_EN_GB_1.pdf?v=1767676312\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e24 AWG 8P Helukabel 21083 PAAR-TRONIC-CY-CY PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a control and signal cable in electronic engineering, measurement and control technology. It provides interference-free transmission of data signals from peripheral equipment to information storage. Excellent connection cable for sound mixers, studio equipment and measurement and control technology. Reliable in process control, machining centers and safety-related systems. These cables with copper screening are ideally suited for interefence-free data and signal transmission for measurement and control technology. EMC = Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e24 AWG 8P Helukabel Paar Tronic CY CY cable, PAAR-TRONIC-CY-CY data cable, Helukabel shielded data cable, Helukabel CY-CY control cable, PVC screened data cable Helukabel, Helukabel instrumentation cable, 24 AWG 8P Pair-screened PVC data cable, Helukabel EMC data cable, Helukabel flexible data cable, 24 AWG 8P Helukabel signal control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 350 V 0.25 - 0.5 mm²: 500 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 1200 V\u003cbr\u003e0.25 - 0.5 mm²: 2000 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e800 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 2400 V\u003cbr\u003e0.25 - 0.5 mm²: 4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003e\u003c\/span\u003eat 800 Hz 0.14 mm²: approx. 147 pF\/m 0.25 mm²: approx. 152 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/screen\u003cbr\u003e\u003c\/strong\u003eat 800 Hz 0.14 mm²: approx. 220 pF\/m 0.25 mm²: approx. 263 pF\/m\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 250 pF\/100m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance \u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12x Outer-Ø\u003cbr\u003efixed 6x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths\u003cbr\u003e• Screening element: pairs, braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• PVC sheath over each screened pair\u003cbr\u003e• Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e24 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 8 x 2 x 0.25\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 16.8\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e178.7\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e330.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62876681896305,"sku":"NNC21083","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_bf00a8a6-fc2f-4b0a-abf6-91bfda7c3114.png?v=1767676691"},{"product_id":"24-awg-10p-helukabel-21084-paar-tronic-cy-cy-pvc-data-cable","title":"24 AWG 10P Helukabel 21084 PAAR-TRONIC-CY-CY PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M21065_EN_GB_1.pdf?v=1767676312\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e24 AWG 10P Helukabel 21084 PAAR-TRONIC-CY-CY PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a control and signal cable in electronic engineering, measurement and control technology. It provides interference-free transmission of data signals from peripheral equipment to information storage. Excellent connection cable for sound mixers, studio equipment and measurement and control technology. Reliable in process control, machining centers and safety-related systems. These cables with copper screening are ideally suited for interefence-free data and signal transmission for measurement and control technology. EMC = Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e24 AWG 10P Helukabel Paar Tronic CY CY cable, PAAR-TRONIC-CY-CY data cable, Helukabel shielded data cable, Helukabel CY-CY control cable, PVC screened data cable Helukabel, Helukabel instrumentation cable, 24 AWG 10P Pair-screened PVC data cable, Helukabel EMC data cable, Helukabel flexible data cable, 24 AWG 10P Helukabel signal control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 350 V 0.25 - 0.5 mm²: 500 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 1200 V\u003cbr\u003e0.25 - 0.5 mm²: 2000 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e800 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 2400 V\u003cbr\u003e0.25 - 0.5 mm²: 4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003e\u003c\/span\u003eat 800 Hz 0.14 mm²: approx. 147 pF\/m 0.25 mm²: approx. 152 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/screen\u003cbr\u003e\u003c\/strong\u003eat 800 Hz 0.14 mm²: approx. 220 pF\/m 0.25 mm²: approx. 263 pF\/m\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 250 pF\/100m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance \u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12x Outer-Ø\u003cbr\u003efixed 6x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths\u003cbr\u003e• Screening element: pairs, braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• PVC sheath over each screened pair\u003cbr\u003e• Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e24 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 10 x 2 x 0.25\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 18.4\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e213.9\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e420.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62876692709745,"sku":"NNC21084","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_bf00a8a6-fc2f-4b0a-abf6-91bfda7c3114.png?v=1767676691"},{"product_id":"24-awg-12p-helukabel-21085-paar-tronic-cy-cy-pvc-data-cable","title":"24 AWG 12P Helukabel 21085 PAAR-TRONIC-CY-CY PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M21065_EN_GB_1.pdf?v=1767676312\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e24 AWG 12P Helukabel 21085 PAAR-TRONIC-CY-CY PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a control and signal cable in electronic engineering, measurement and control technology. It provides interference-free transmission of data signals from peripheral equipment to information storage. Excellent connection cable for sound mixers, studio equipment and measurement and control technology. Reliable in process control, machining centers and safety-related systems. These cables with copper screening are ideally suited for interefence-free data and signal transmission for measurement and control technology. EMC = Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e24 AWG 12P Helukabel Paar Tronic CY CY cable, PAAR-TRONIC-CY-CY data cable, Helukabel shielded data cable, Helukabel CY-CY control cable, PVC screened data cable Helukabel, Helukabel instrumentation cable, 24 AWG 12P Pair-screened PVC data cable, Helukabel EMC data cable, Helukabel flexible data cable, 24 AWG 12P Helukabel signal control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 350 V 0.25 - 0.5 mm²: 500 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 1200 V\u003cbr\u003e0.25 - 0.5 mm²: 2000 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e800 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 2400 V\u003cbr\u003e0.25 - 0.5 mm²: 4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003e\u003c\/span\u003eat 800 Hz 0.14 mm²: approx. 147 pF\/m 0.25 mm²: approx. 152 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/screen\u003cbr\u003e\u003c\/strong\u003eat 800 Hz 0.14 mm²: approx. 220 pF\/m 0.25 mm²: approx. 263 pF\/m\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 250 pF\/100m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance \u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12x Outer-Ø\u003cbr\u003efixed 6x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths\u003cbr\u003e• Screening element: pairs, braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• PVC sheath over each screened pair\u003cbr\u003e• Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e24 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 12 x 2 x 0.25\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 19.4\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e238.3\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e465.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62876706767217,"sku":"NNC21085","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_bf00a8a6-fc2f-4b0a-abf6-91bfda7c3114.png?v=1767676691"},{"product_id":"24-awg-16p-helukabel-21086-paar-tronic-cy-cy-pvc-data-cable","title":"24 AWG 16P Helukabel 21086 PAAR-TRONIC-CY-CY PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M21065_EN_GB_1.pdf?v=1767676312\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e24 AWG 16P Helukabel 21086 PAAR-TRONIC-CY-CY PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a control and signal cable in electronic engineering, measurement and control technology. It provides interference-free transmission of data signals from peripheral equipment to information storage. Excellent connection cable for sound mixers, studio equipment and measurement and control technology. Reliable in process control, machining centers and safety-related systems. These cables with copper screening are ideally suited for interefence-free data and signal transmission for measurement and control technology. EMC = Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e24 AWG 16P Helukabel Paar Tronic CY CY cable, PAAR-TRONIC-CY-CY data cable, Helukabel shielded data cable, Helukabel CY-CY control cable, PVC screened data cable Helukabel, Helukabel instrumentation cable, 24 AWG 16P Pair-screened PVC data cable, Helukabel EMC data cable, Helukabel flexible data cable, 24 AWG 16P Helukabel signal control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 350 V 0.25 - 0.5 mm²: 500 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 1200 V\u003cbr\u003e0.25 - 0.5 mm²: 2000 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e800 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 2400 V\u003cbr\u003e0.25 - 0.5 mm²: 4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003e\u003c\/span\u003eat 800 Hz 0.14 mm²: approx. 147 pF\/m 0.25 mm²: approx. 152 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/screen\u003cbr\u003e\u003c\/strong\u003eat 800 Hz 0.14 mm²: approx. 220 pF\/m 0.25 mm²: approx. 263 pF\/m\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 250 pF\/100m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance \u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12x Outer-Ø\u003cbr\u003efixed 6x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths\u003cbr\u003e• Screening element: pairs, braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• PVC sheath over each screened pair\u003cbr\u003e• Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e24 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 16 x 2 x 0.25\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 21.6\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e291.4\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e590.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62876717449585,"sku":"NNC21086","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_bf00a8a6-fc2f-4b0a-abf6-91bfda7c3114.png?v=1767676691"},{"product_id":"24-awg-20p-helukabel-21087-paar-tronic-cy-cy-pvc-data-cable","title":"24 AWG 20P Helukabel 21087 PAAR-TRONIC-CY-CY PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M21065_EN_GB_1.pdf?v=1767676312\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e24 AWG 20P Helukabel 21087 PAAR-TRONIC-CY-CY PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a control and signal cable in electronic engineering, measurement and control technology. It provides interference-free transmission of data signals from peripheral equipment to information storage. Excellent connection cable for sound mixers, studio equipment and measurement and control technology. Reliable in process control, machining centers and safety-related systems. These cables with copper screening are ideally suited for interefence-free data and signal transmission for measurement and control technology. EMC = Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e24 AWG 20P Helukabel Paar Tronic CY CY cable, PAAR-TRONIC-CY-CY data cable, Helukabel shielded data cable, Helukabel CY-CY control cable, PVC screened data cable Helukabel, Helukabel instrumentation cable, 24 AWG 20P Pair-screened PVC data cable, Helukabel EMC data cable, Helukabel flexible data cable, 24 AWG 20P Helukabel signal control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 350 V 0.25 - 0.5 mm²: 500 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 1200 V\u003cbr\u003e0.25 - 0.5 mm²: 2000 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e800 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 2400 V\u003cbr\u003e0.25 - 0.5 mm²: 4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003e\u003c\/span\u003eat 800 Hz 0.14 mm²: approx. 147 pF\/m 0.25 mm²: approx. 152 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/screen\u003cbr\u003e\u003c\/strong\u003eat 800 Hz 0.14 mm²: approx. 220 pF\/m 0.25 mm²: approx. 263 pF\/m\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 250 pF\/100m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance \u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12x Outer-Ø\u003cbr\u003efixed 6x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths\u003cbr\u003e• Screening element: pairs, braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• PVC sheath over each screened pair\u003cbr\u003e• Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e24 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 20 x 2 x 0.25\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 24.3\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e325.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e620.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62876723741041,"sku":"NNC21087","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_bf00a8a6-fc2f-4b0a-abf6-91bfda7c3114.png?v=1767676691"},{"product_id":"24-awg-24p-helukabel-21088-paar-tronic-cy-cy-pvc-data-cable","title":"24 AWG 24P Helukabel 21088 PAAR-TRONIC-CY-CY PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M21065_EN_GB_1.pdf?v=1767676312\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e24 AWG 24P Helukabel 21088 PAAR-TRONIC-CY-CY PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a control and signal cable in electronic engineering, measurement and control technology. It provides interference-free transmission of data signals from peripheral equipment to information storage. Excellent connection cable for sound mixers, studio equipment and measurement and control technology. Reliable in process control, machining centers and safety-related systems. These cables with copper screening are ideally suited for interefence-free data and signal transmission for measurement and control technology. EMC = Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e24 AWG 24P Helukabel Paar Tronic CY CY cable, PAAR-TRONIC-CY-CY data cable, Helukabel shielded data cable, Helukabel CY-CY control cable, PVC screened data cable Helukabel, Helukabel instrumentation cable, 24 AWG 24P Pair-screened PVC data cable, Helukabel EMC data cable, Helukabel flexible data cable, 24 AWG 24P Helukabel signal control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 350 V 0.25 - 0.5 mm²: 500 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 1200 V\u003cbr\u003e0.25 - 0.5 mm²: 2000 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e800 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 2400 V\u003cbr\u003e0.25 - 0.5 mm²: 4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003e\u003c\/span\u003eat 800 Hz 0.14 mm²: approx. 147 pF\/m 0.25 mm²: approx. 152 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/screen\u003cbr\u003e\u003c\/strong\u003eat 800 Hz 0.14 mm²: approx. 220 pF\/m 0.25 mm²: approx. 263 pF\/m\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 250 pF\/100m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance \u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12x Outer-Ø\u003cbr\u003efixed 6x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths\u003cbr\u003e• Screening element: pairs, braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• PVC sheath over each screened pair\u003cbr\u003e• Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e24 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 24 x 2 x 0.25\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 27.4\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e367.5\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e690.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62876730524017,"sku":"NNC21088","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_bf00a8a6-fc2f-4b0a-abf6-91bfda7c3114.png?v=1767676691"},{"product_id":"24-awg-32p-helukabel-21089-paar-tronic-cy-cy-pvc-data-cable","title":"24 AWG 32P Helukabel 21089 PAAR-TRONIC-CY-CY PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M21065_EN_GB_1.pdf?v=1767676312\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e24 AWG 32P Helukabel 21089 PAAR-TRONIC-CY-CY PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a control and signal cable in electronic engineering, measurement and control technology. It provides interference-free transmission of data signals from peripheral equipment to information storage. Excellent connection cable for sound mixers, studio equipment and measurement and control technology. Reliable in process control, machining centers and safety-related systems. These cables with copper screening are ideally suited for interefence-free data and signal transmission for measurement and control technology. EMC = Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e24 AWG 32P Helukabel Paar Tronic CY CY cable, PAAR-TRONIC-CY-CY data cable, Helukabel shielded data cable, Helukabel CY-CY control cable, PVC screened data cable Helukabel, Helukabel instrumentation cable, 24 AWG 32P Pair-screened PVC data cable, Helukabel EMC data cable, Helukabel flexible data cable, 24 AWG 32P Helukabel signal control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 350 V 0.25 - 0.5 mm²: 500 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 1200 V\u003cbr\u003e0.25 - 0.5 mm²: 2000 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e800 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 2400 V\u003cbr\u003e0.25 - 0.5 mm²: 4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003e\u003c\/span\u003eat 800 Hz 0.14 mm²: approx. 147 pF\/m 0.25 mm²: approx. 152 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/screen\u003cbr\u003e\u003c\/strong\u003eat 800 Hz 0.14 mm²: approx. 220 pF\/m 0.25 mm²: approx. 263 pF\/m\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 250 pF\/100m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance \u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12x Outer-Ø\u003cbr\u003efixed 6x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths\u003cbr\u003e• Screening element: pairs, braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• PVC sheath over each screened pair\u003cbr\u003e• Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e24 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 32 x 2 x 0.25\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 30.3\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e588.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e785.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62876745630065,"sku":"NNC21089","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_bf00a8a6-fc2f-4b0a-abf6-91bfda7c3114.png?v=1767676691"},{"product_id":"24-awg-48p-helukabel-21090-paar-tronic-cy-cy-pvc-data-cable","title":"24 AWG 48P Helukabel 21090 PAAR-TRONIC-CY-CY PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M21065_EN_GB_1.pdf?v=1767676312\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e24 AWG 48P Helukabel 21090 PAAR-TRONIC-CY-CY PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a control and signal cable in electronic engineering, measurement and control technology. It provides interference-free transmission of data signals from peripheral equipment to information storage. Excellent connection cable for sound mixers, studio equipment and measurement and control technology. Reliable in process control, machining centers and safety-related systems. These cables with copper screening are ideally suited for interefence-free data and signal transmission for measurement and control technology. EMC = Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e24 AWG 48P Helukabel Paar Tronic CY CY cable, PAAR-TRONIC-CY-CY data cable, Helukabel shielded data cable, Helukabel CY-CY control cable, PVC screened data cable Helukabel, Helukabel instrumentation cable, 24 AWG 48P Pair-screened PVC data cable, Helukabel EMC data cable, Helukabel flexible data cable, 24 AWG 48P Helukabel signal control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 350 V 0.25 - 0.5 mm²: 500 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 1200 V\u003cbr\u003e0.25 - 0.5 mm²: 2000 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e800 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 2400 V\u003cbr\u003e0.25 - 0.5 mm²: 4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003e\u003c\/span\u003eat 800 Hz 0.14 mm²: approx. 147 pF\/m 0.25 mm²: approx. 152 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/screen\u003cbr\u003e\u003c\/strong\u003eat 800 Hz 0.14 mm²: approx. 220 pF\/m 0.25 mm²: approx. 263 pF\/m\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 250 pF\/100m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance \u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12x Outer-Ø\u003cbr\u003efixed 6x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths\u003cbr\u003e• Screening element: pairs, braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• PVC sheath over each screened pair\u003cbr\u003e• Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e24 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 48 x 2 x 0.25\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 36.3\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e840.5\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e970.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62876804645233,"sku":"NNC21090","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_bf00a8a6-fc2f-4b0a-abf6-91bfda7c3114.png?v=1767676691"},{"product_id":"22-awg-2p-helukabel-21091-paar-tronic-cy-cy-pvc-data-cable","title":"22 AWG 2P Helukabel 21091 PAAR-TRONIC-CY-CY PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M21065_EN_GB_1.pdf?v=1767676312\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e22 AWG 2P Helukabel 21091 PAAR-TRONIC-CY-CY PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a control and signal cable in electronic engineering, measurement and control technology. It provides interference-free transmission of data signals from peripheral equipment to information storage. Excellent connection cable for sound mixers, studio equipment and measurement and control technology. Reliable in process control, machining centers and safety-related systems. These cables with copper screening are ideally suited for interefence-free data and signal transmission for measurement and control technology. EMC = Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e22 AWG 2P Helukabel Paar Tronic CY CY cable, PAAR-TRONIC-CY-CY data cable, Helukabel shielded data cable, Helukabel CY-CY control cable, PVC screened data cable Helukabel, Helukabel instrumentation cable, 22 AWG 2P Pair-screened PVC data cable, Helukabel EMC data cable, Helukabel flexible data cable, 22 AWG 2P Helukabel signal control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 350 V 0.25 - 0.5 mm²: 500 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 1200 V\u003cbr\u003e0.25 - 0.5 mm²: 2000 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e800 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 2400 V\u003cbr\u003e0.25 - 0.5 mm²: 4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003e\u003c\/span\u003eat 800 Hz 0.14 mm²: approx. 147 pF\/m 0.25 mm²: approx. 152 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/screen\u003cbr\u003e\u003c\/strong\u003eat 800 Hz 0.14 mm²: approx. 220 pF\/m 0.25 mm²: approx. 263 pF\/m\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 250 pF\/100m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance \u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12x Outer-Ø\u003cbr\u003efixed 6x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths\u003cbr\u003e• Screening element: pairs, braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• PVC sheath over each screened pair\u003cbr\u003e• Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e22 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 2 x 2 x 0.34\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 10.1\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e73.1\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e139.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62876814705009,"sku":"NNC21091","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_bf00a8a6-fc2f-4b0a-abf6-91bfda7c3114.png?v=1767676691"},{"product_id":"22-awg-3p-helukabel-21092-paar-tronic-cy-cy-pvc-data-cable","title":"22 AWG 3P Helukabel 21092 PAAR-TRONIC-CY-CY PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M21065_EN_GB_1.pdf?v=1767676312\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e22 AWG 3P Helukabel 21092 PAAR-TRONIC-CY-CY PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a control and signal cable in electronic engineering, measurement and control technology. It provides interference-free transmission of data signals from peripheral equipment to information storage. Excellent connection cable for sound mixers, studio equipment and measurement and control technology. Reliable in process control, machining centers and safety-related systems. These cables with copper screening are ideally suited for interefence-free data and signal transmission for measurement and control technology. EMC = Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e22 AWG 3P Helukabel Paar Tronic CY CY cable, PAAR-TRONIC-CY-CY data cable, Helukabel shielded data cable, Helukabel CY-CY control cable, PVC screened data cable Helukabel, Helukabel instrumentation cable, 22 AWG 3P Pair-screened PVC data cable, Helukabel EMC data cable, Helukabel flexible data cable, 22 AWG 3P Helukabel signal control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 350 V 0.25 - 0.5 mm²: 500 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 1200 V\u003cbr\u003e0.25 - 0.5 mm²: 2000 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e800 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 2400 V\u003cbr\u003e0.25 - 0.5 mm²: 4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003e\u003c\/span\u003eat 800 Hz 0.14 mm²: approx. 147 pF\/m 0.25 mm²: approx. 152 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/screen\u003cbr\u003e\u003c\/strong\u003eat 800 Hz 0.14 mm²: approx. 220 pF\/m 0.25 mm²: approx. 263 pF\/m\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 250 pF\/100m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance \u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12x Outer-Ø\u003cbr\u003efixed 6x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths\u003cbr\u003e• Screening element: pairs, braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• PVC sheath over each screened pair\u003cbr\u003e• Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e22 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 3 x 2 x 0.34\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 11.0\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e88.1\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e157.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62876823716209,"sku":"NNC21092","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_bf00a8a6-fc2f-4b0a-abf6-91bfda7c3114.png?v=1767676691"},{"product_id":"22-awg-4p-helukabel-21093-paar-tronic-cy-cy-pvc-data-cable","title":"22 AWG 4P Helukabel 21093 PAAR-TRONIC-CY-CY PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M21065_EN_GB_1.pdf?v=1767676312\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e22 AWG 4P Helukabel 21093 PAAR-TRONIC-CY-CY PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a control and signal cable in electronic engineering, measurement and control technology. It provides interference-free transmission of data signals from peripheral equipment to information storage. Excellent connection cable for sound mixers, studio equipment and measurement and control technology. Reliable in process control, machining centers and safety-related systems. These cables with copper screening are ideally suited for interefence-free data and signal transmission for measurement and control technology. EMC = Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e22 AWG 4P Helukabel Paar Tronic CY CY cable, PAAR-TRONIC-CY-CY data cable, Helukabel shielded data cable, Helukabel CY-CY control cable, PVC screened data cable Helukabel, Helukabel instrumentation cable, 22 AWG 4P Pair-screened PVC data cable, Helukabel EMC data cable, Helukabel flexible data cable, 22 AWG 4P Helukabel signal control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 350 V 0.25 - 0.5 mm²: 500 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 1200 V\u003cbr\u003e0.25 - 0.5 mm²: 2000 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e800 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 2400 V\u003cbr\u003e0.25 - 0.5 mm²: 4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003e\u003c\/span\u003eat 800 Hz 0.14 mm²: approx. 147 pF\/m 0.25 mm²: approx. 152 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/screen\u003cbr\u003e\u003c\/strong\u003eat 800 Hz 0.14 mm²: approx. 220 pF\/m 0.25 mm²: approx. 263 pF\/m\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 250 pF\/100m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance \u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12x Outer-Ø\u003cbr\u003efixed 6x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths\u003cbr\u003e• Screening element: pairs, braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• PVC sheath over each screened pair\u003cbr\u003e• Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e22 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 4 x 2 x 0.34\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 12.2\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e137.2\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e213.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62876833186161,"sku":"NNC21093","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_bf00a8a6-fc2f-4b0a-abf6-91bfda7c3114.png?v=1767676691"},{"product_id":"22-awg-6p-helukabel-21094-paar-tronic-cy-cy-pvc-data-cable","title":"22 AWG 6P Helukabel 21094 PAAR-TRONIC-CY-CY PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M21065_EN_GB_1.pdf?v=1767676312\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e22 AWG 6P Helukabel 21094 PAAR-TRONIC-CY-CY PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a control and signal cable in electronic engineering, measurement and control technology. It provides interference-free transmission of data signals from peripheral equipment to information storage. Excellent connection cable for sound mixers, studio equipment and measurement and control technology. Reliable in process control, machining centers and safety-related systems. These cables with copper screening are ideally suited for interefence-free data and signal transmission for measurement and control technology. EMC = Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e22 AWG 6P Helukabel Paar Tronic CY CY cable, PAAR-TRONIC-CY-CY data cable, Helukabel shielded data cable, Helukabel CY-CY control cable, PVC screened data cable Helukabel, Helukabel instrumentation cable, 22 AWG 6P Pair-screened PVC data cable, Helukabel EMC data cable, Helukabel flexible data cable, 22 AWG 6P Helukabel signal control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 350 V 0.25 - 0.5 mm²: 500 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 1200 V\u003cbr\u003e0.25 - 0.5 mm²: 2000 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e800 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 2400 V\u003cbr\u003e0.25 - 0.5 mm²: 4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003e\u003c\/span\u003eat 800 Hz 0.14 mm²: approx. 147 pF\/m 0.25 mm²: approx. 152 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/screen\u003cbr\u003e\u003c\/strong\u003eat 800 Hz 0.14 mm²: approx. 220 pF\/m 0.25 mm²: approx. 263 pF\/m\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 250 pF\/100m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance \u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12x Outer-Ø\u003cbr\u003efixed 6x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths\u003cbr\u003e• Screening element: pairs, braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• PVC sheath over each screened pair\u003cbr\u003e• Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e22 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 6 x 2 x 0.34 \u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 15.0\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e174.8\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e308.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62876842000753,"sku":"NNC21094","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_bf00a8a6-fc2f-4b0a-abf6-91bfda7c3114.png?v=1767676691"},{"product_id":"22-awg-8p-helukabel-21095-paar-tronic-cy-cy-pvc-data-cable","title":"22 AWG 8P Helukabel 21095 PAAR-TRONIC-CY-CY PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M21065_EN_GB_1.pdf?v=1767676312\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e22 AWG 8P Helukabel 21095 PAAR-TRONIC-CY-CY PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a control and signal cable in electronic engineering, measurement and control technology. It provides interference-free transmission of data signals from peripheral equipment to information storage. Excellent connection cable for sound mixers, studio equipment and measurement and control technology. Reliable in process control, machining centers and safety-related systems. These cables with copper screening are ideally suited for interefence-free data and signal transmission for measurement and control technology. EMC = Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e22 AWG 8P Helukabel Paar Tronic CY CY cable, PAAR-TRONIC-CY-CY data cable, Helukabel shielded data cable, Helukabel CY-CY control cable, PVC screened data cable Helukabel, Helukabel instrumentation cable, 22 AWG 8P Pair-screened PVC data cable, Helukabel EMC data cable, Helukabel flexible data cable, 22 AWG 8P Helukabel signal control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 350 V 0.25 - 0.5 mm²: 500 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 1200 V\u003cbr\u003e0.25 - 0.5 mm²: 2000 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e800 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 2400 V\u003cbr\u003e0.25 - 0.5 mm²: 4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003e\u003c\/span\u003eat 800 Hz 0.14 mm²: approx. 147 pF\/m 0.25 mm²: approx. 152 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/screen\u003cbr\u003e\u003c\/strong\u003eat 800 Hz 0.14 mm²: approx. 220 pF\/m 0.25 mm²: approx. 263 pF\/m\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 250 pF\/100m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance \u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12x Outer-Ø\u003cbr\u003efixed 6x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths\u003cbr\u003e• Screening element: pairs, braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• PVC sheath over each screened pair\u003cbr\u003e• Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e22 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 8 x 2 x 0.34\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 17.6\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e247.2\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e385.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62876850192753,"sku":"NNC21095","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_bf00a8a6-fc2f-4b0a-abf6-91bfda7c3114.png?v=1767676691"},{"product_id":"22-awg-10p-helukabel-21096-paar-tronic-cy-cy-pvc-data-cable","title":"22 AWG 10P Helukabel 21096 PAAR-TRONIC-CY-CY PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M21065_EN_GB_1.pdf?v=1767676312\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e22 AWG 10P Helukabel 21096 PAAR-TRONIC-CY-CY PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a control and signal cable in electronic engineering, measurement and control technology. It provides interference-free transmission of data signals from peripheral equipment to information storage. Excellent connection cable for sound mixers, studio equipment and measurement and control technology. Reliable in process control, machining centers and safety-related systems. These cables with copper screening are ideally suited for interefence-free data and signal transmission for measurement and control technology. EMC = Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e22 AWG 10P Helukabel Paar Tronic CY CY cable, PAAR-TRONIC-CY-CY data cable, Helukabel shielded data cable, Helukabel CY-CY control cable, PVC screened data cable Helukabel, Helukabel instrumentation cable, 22 AWG 10P Pair-screened PVC data cable, Helukabel EMC data cable, Helukabel flexible data cable, 22 AWG 10P Helukabel signal control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 350 V 0.25 - 0.5 mm²: 500 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 1200 V\u003cbr\u003e0.25 - 0.5 mm²: 2000 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e800 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 2400 V\u003cbr\u003e0.25 - 0.5 mm²: 4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003e\u003c\/span\u003eat 800 Hz 0.14 mm²: approx. 147 pF\/m 0.25 mm²: approx. 152 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/screen\u003cbr\u003e\u003c\/strong\u003eat 800 Hz 0.14 mm²: approx. 220 pF\/m 0.25 mm²: approx. 263 pF\/m\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 250 pF\/100m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance \u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12x Outer-Ø\u003cbr\u003efixed 6x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths\u003cbr\u003e• Screening element: pairs, braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• PVC sheath over each screened pair\u003cbr\u003e• Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e22 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 10 x 2 x 0.34 \u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 19.5\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e288.7\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e433.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62876856418673,"sku":"NNC21096","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_bf00a8a6-fc2f-4b0a-abf6-91bfda7c3114.png?v=1767676691"},{"product_id":"22-awg-12p-helukabel-21097-paar-tronic-cy-cy-pvc-data-cable","title":"22 AWG 12P Helukabel 21097 PAAR-TRONIC-CY-CY PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M21065_EN_GB_1.pdf?v=1767676312\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e22 AWG 12P Helukabel 21097 PAAR-TRONIC-CY-CY PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a control and signal cable in electronic engineering, measurement and control technology. It provides interference-free transmission of data signals from peripheral equipment to information storage. Excellent connection cable for sound mixers, studio equipment and measurement and control technology. Reliable in process control, machining centers and safety-related systems. These cables with copper screening are ideally suited for interefence-free data and signal transmission for measurement and control technology. EMC = Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e22 AWG 12P Helukabel Paar Tronic CY CY cable, PAAR-TRONIC-CY-CY data cable, Helukabel shielded data cable, Helukabel CY-CY control cable, PVC screened data cable Helukabel, Helukabel instrumentation cable, 22 AWG 12P Pair-screened PVC data cable, Helukabel EMC data cable, Helukabel flexible data cable, 22 AWG 12P Helukabel signal control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 350 V 0.25 - 0.5 mm²: 500 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 1200 V\u003cbr\u003e0.25 - 0.5 mm²: 2000 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e800 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 2400 V\u003cbr\u003e0.25 - 0.5 mm²: 4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003e\u003c\/span\u003eat 800 Hz 0.14 mm²: approx. 147 pF\/m 0.25 mm²: approx. 152 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/screen\u003cbr\u003e\u003c\/strong\u003eat 800 Hz 0.14 mm²: approx. 220 pF\/m 0.25 mm²: approx. 263 pF\/m\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 250 pF\/100m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance \u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12x Outer-Ø\u003cbr\u003efixed 6x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths\u003cbr\u003e• Screening element: pairs, braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• PVC sheath over each screened pair\u003cbr\u003e• Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e22 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 12 x 2 x 0.34 \u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 20.3\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e321.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e495.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62876862316913,"sku":"NNC21097","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_bf00a8a6-fc2f-4b0a-abf6-91bfda7c3114.png?v=1767676691"},{"product_id":"22-awg-14p-helukabel-21098-paar-tronic-cy-cy-pvc-data-cable","title":"22 AWG 14P Helukabel 21098 PAAR-TRONIC-CY-CY PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M21065_EN_GB_1.pdf?v=1767676312\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e22 AWG 14P Helukabel 21098 PAAR-TRONIC-CY-CY PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a control and signal cable in electronic engineering, measurement and control technology. It provides interference-free transmission of data signals from peripheral equipment to information storage. Excellent connection cable for sound mixers, studio equipment and measurement and control technology. Reliable in process control, machining centers and safety-related systems. These cables with copper screening are ideally suited for interefence-free data and signal transmission for measurement and control technology. EMC = Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e22 AWG 14P Helukabel Paar Tronic CY CY cable, PAAR-TRONIC-CY-CY data cable, Helukabel shielded data cable, Helukabel CY-CY control cable, PVC screened data cable Helukabel, Helukabel instrumentation cable, 22 AWG 14P Pair-screened PVC data cable, Helukabel EMC data cable, Helukabel flexible data cable, 22 AWG 14P Helukabel signal control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 350 V 0.25 - 0.5 mm²: 500 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 1200 V\u003cbr\u003e0.25 - 0.5 mm²: 2000 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e800 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 2400 V\u003cbr\u003e0.25 - 0.5 mm²: 4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003e\u003c\/span\u003eat 800 Hz 0.14 mm²: approx. 147 pF\/m 0.25 mm²: approx. 152 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/screen\u003cbr\u003e\u003c\/strong\u003eat 800 Hz 0.14 mm²: approx. 220 pF\/m 0.25 mm²: approx. 263 pF\/m\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 250 pF\/100m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance \u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12x Outer-Ø\u003cbr\u003efixed 6x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths\u003cbr\u003e• Screening element: pairs, braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• PVC sheath over each screened pair\u003cbr\u003e• Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e22 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 14 x 2 x 0.34\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 21.5\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e388.4 \u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e600.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62876867887473,"sku":"NNC21098","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_bf00a8a6-fc2f-4b0a-abf6-91bfda7c3114.png?v=1767676691"},{"product_id":"22-awg-16p-helukabel-21099-paar-tronic-cy-cy-pvc-data-cable","title":"22 AWG 16P Helukabel 21099 PAAR-TRONIC-CY-CY PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M21065_EN_GB_1.pdf?v=1767676312\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e22 AWG 16P Helukabel 21099 PAAR-TRONIC-CY-CY PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a control and signal cable in electronic engineering, measurement and control technology. It provides interference-free transmission of data signals from peripheral equipment to information storage. Excellent connection cable for sound mixers, studio equipment and measurement and control technology. Reliable in process control, machining centers and safety-related systems. These cables with copper screening are ideally suited for interefence-free data and signal transmission for measurement and control technology. EMC = Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e22 AWG 16P Helukabel Paar Tronic CY CY cable, PAAR-TRONIC-CY-CY data cable, Helukabel shielded data cable, Helukabel CY-CY control cable, PVC screened data cable Helukabel, Helukabel instrumentation cable, 22 AWG 16P Pair-screened PVC data cable, Helukabel EMC data cable, Helukabel flexible data cable, 22 AWG 16P Helukabel signal control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 350 V 0.25 - 0.5 mm²: 500 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 1200 V\u003cbr\u003e0.25 - 0.5 mm²: 2000 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e800 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 2400 V\u003cbr\u003e0.25 - 0.5 mm²: 4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003e\u003c\/span\u003eat 800 Hz 0.14 mm²: approx. 147 pF\/m 0.25 mm²: approx. 152 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/screen\u003cbr\u003e\u003c\/strong\u003eat 800 Hz 0.14 mm²: approx. 220 pF\/m 0.25 mm²: approx. 263 pF\/m\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 250 pF\/100m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance \u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12x Outer-Ø\u003cbr\u003efixed 6x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths\u003cbr\u003e• Screening element: pairs, braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• PVC sheath over each screened pair\u003cbr\u003e• Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e22 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 16 x 2 x 0.34\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 22.6 \u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e425.5\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e637.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62876875489649,"sku":"NNC21099","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_bf00a8a6-fc2f-4b0a-abf6-91bfda7c3114.png?v=1767676691"},{"product_id":"22-awg-24p-helukabel-21100-paar-tronic-cy-cy-pvc-data-cable","title":"22 AWG 24P Helukabel 21100 PAAR-TRONIC-CY-CY PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M21065_EN_GB_1.pdf?v=1767676312\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e22 AWG 24P Helukabel 21100 PAAR-TRONIC-CY-CY PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a control and signal cable in electronic engineering, measurement and control technology. It provides interference-free transmission of data signals from peripheral equipment to information storage. Excellent connection cable for sound mixers, studio equipment and measurement and control technology. Reliable in process control, machining centers and safety-related systems. These cables with copper screening are ideally suited for interefence-free data and signal transmission for measurement and control technology. EMC = Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e22 AWG 24P Helukabel Paar Tronic CY CY cable, PAAR-TRONIC-CY-CY data cable, Helukabel shielded data cable, Helukabel CY-CY control cable, PVC screened data cable Helukabel, Helukabel instrumentation cable, 22 AWG 24P Pair-screened PVC data cable, Helukabel EMC data cable, Helukabel flexible data cable, 22 AWG 24P Helukabel signal control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 350 V 0.25 - 0.5 mm²: 500 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 1200 V\u003cbr\u003e0.25 - 0.5 mm²: 2000 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e800 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 2400 V\u003cbr\u003e0.25 - 0.5 mm²: 4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003e\u003c\/span\u003eat 800 Hz 0.14 mm²: approx. 147 pF\/m 0.25 mm²: approx. 152 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/screen\u003cbr\u003e\u003c\/strong\u003eat 800 Hz 0.14 mm²: approx. 220 pF\/m 0.25 mm²: approx. 263 pF\/m\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 250 pF\/100m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance \u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12x Outer-Ø\u003cbr\u003efixed 6x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths\u003cbr\u003e• Screening element: pairs, braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• PVC sheath over each screened pair\u003cbr\u003e• Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e22 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 24 x 2 x 0.34\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 28.6\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e577.1\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e781.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62876882076017,"sku":"NNC21100","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_bf00a8a6-fc2f-4b0a-abf6-91bfda7c3114.png?v=1767676691"},{"product_id":"20-awg-2p-helukabel-21101-paar-tronic-cy-cy-pvc-data-cable","title":"20 AWG 2P Helukabel 21101 PAAR-TRONIC-CY-CY PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M21065_EN_GB_1.pdf?v=1767676312\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 2P Helukabel 21101 PAAR-TRONIC-CY-CY PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a control and signal cable in electronic engineering, measurement and control technology. It provides interference-free transmission of data signals from peripheral equipment to information storage. Excellent connection cable for sound mixers, studio equipment and measurement and control technology. Reliable in process control, machining centers and safety-related systems. These cables with copper screening are ideally suited for interefence-free data and signal transmission for measurement and control technology. EMC = Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e20 AWG 2P Helukabel Paar Tronic CY CY cable, PAAR-TRONIC-CY-CY data cable, Helukabel shielded data cable, Helukabel CY-CY control cable, PVC screened data cable Helukabel, Helukabel instrumentation cable, 20 AWG 2P Pair-screened PVC data cable, Helukabel EMC data cable, Helukabel flexible data cable, 20 AWG 2P Helukabel signal control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 350 V 0.25 - 0.5 mm²: 500 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 1200 V\u003cbr\u003e0.25 - 0.5 mm²: 2000 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e800 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 2400 V\u003cbr\u003e0.25 - 0.5 mm²: 4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003e\u003c\/span\u003eat 800 Hz 0.14 mm²: approx. 147 pF\/m 0.25 mm²: approx. 152 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/screen\u003cbr\u003e\u003c\/strong\u003eat 800 Hz 0.14 mm²: approx. 220 pF\/m 0.25 mm²: approx. 263 pF\/m\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 250 pF\/100m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance \u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12x Outer-Ø\u003cbr\u003efixed 6x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths\u003cbr\u003e• Screening element: pairs, braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• PVC sheath over each screened pair\u003cbr\u003e• Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e20 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 2 x 2 x 0.5\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 11.2\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e83.1\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e143.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62876890759537,"sku":"NNC21101","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_bf00a8a6-fc2f-4b0a-abf6-91bfda7c3114.png?v=1767676691"},{"product_id":"20-awg-3p-helukabel-21102-paar-tronic-cy-cy-pvc-data-cable","title":"20 AWG 3P Helukabel 21102 PAAR-TRONIC-CY-CY PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M21065_EN_GB_1.pdf?v=1767676312\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 3P Helukabel 21102 PAAR-TRONIC-CY-CY PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a control and signal cable in electronic engineering, measurement and control technology. It provides interference-free transmission of data signals from peripheral equipment to information storage. Excellent connection cable for sound mixers, studio equipment and measurement and control technology. Reliable in process control, machining centers and safety-related systems. These cables with copper screening are ideally suited for interefence-free data and signal transmission for measurement and control technology. EMC = Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e20 AWG 3P Helukabel Paar Tronic CY CY cable, PAAR-TRONIC-CY-CY data cable, Helukabel shielded data cable, Helukabel CY-CY control cable, PVC screened data cable Helukabel, Helukabel instrumentation cable, 20 AWG 3P Pair-screened PVC data cable, Helukabel EMC data cable, Helukabel flexible data cable, 20 AWG 3P Helukabel signal control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 350 V 0.25 - 0.5 mm²: 500 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 1200 V\u003cbr\u003e0.25 - 0.5 mm²: 2000 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e800 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 2400 V\u003cbr\u003e0.25 - 0.5 mm²: 4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003e\u003c\/span\u003eat 800 Hz 0.14 mm²: approx. 147 pF\/m 0.25 mm²: approx. 152 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/screen\u003cbr\u003e\u003c\/strong\u003eat 800 Hz 0.14 mm²: approx. 220 pF\/m 0.25 mm²: approx. 263 pF\/m\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 250 pF\/100m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance \u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12x Outer-Ø\u003cbr\u003efixed 6x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths\u003cbr\u003e• Screening element: pairs, braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• PVC sheath over each screened pair\u003cbr\u003e• Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e20 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 3 x 2 x 0.5\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 12.3\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e106.4\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e179.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62876898427249,"sku":"NNC21102","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_bf00a8a6-fc2f-4b0a-abf6-91bfda7c3114.png?v=1767676691"},{"product_id":"20-awg-4p-helukabel-21103-paar-tronic-cy-cy-pvc-data-cable","title":"20 AWG 4P Helukabel 21103 PAAR-TRONIC-CY-CY PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M21065_EN_GB_1.pdf?v=1767676312\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 4P Helukabel 21103 PAAR-TRONIC-CY-CY PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a control and signal cable in electronic engineering, measurement and control technology. It provides interference-free transmission of data signals from peripheral equipment to information storage. Excellent connection cable for sound mixers, studio equipment and measurement and control technology. Reliable in process control, machining centers and safety-related systems. These cables with copper screening are ideally suited for interefence-free data and signal transmission for measurement and control technology. EMC = Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e20 AWG 4P Helukabel Paar Tronic CY CY cable, PAAR-TRONIC-CY-CY data cable, Helukabel shielded data cable, Helukabel CY-CY control cable, PVC screened data cable Helukabel, Helukabel instrumentation cable, 20 AWG 4P Pair-screened PVC data cable, Helukabel EMC data cable, Helukabel flexible data cable, 20 AWG 4P Helukabel signal control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 350 V 0.25 - 0.5 mm²: 500 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 1200 V\u003cbr\u003e0.25 - 0.5 mm²: 2000 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e800 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 2400 V\u003cbr\u003e0.25 - 0.5 mm²: 4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003e\u003c\/span\u003eat 800 Hz 0.14 mm²: approx. 147 pF\/m 0.25 mm²: approx. 152 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/screen\u003cbr\u003e\u003c\/strong\u003eat 800 Hz 0.14 mm²: approx. 220 pF\/m 0.25 mm²: approx. 263 pF\/m\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 250 pF\/100m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance \u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12x Outer-Ø\u003cbr\u003efixed 6x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths\u003cbr\u003e• Screening element: pairs, braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• PVC sheath over each screened pair\u003cbr\u003e• Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e20 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 4 x 2 x 0.5\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 13.9\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e158.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e241.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62876905177457,"sku":"NNC21103","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_bf00a8a6-fc2f-4b0a-abf6-91bfda7c3114.png?v=1767676691"},{"product_id":"20-awg-6p-helukabel-21104-paar-tronic-cy-cy-pvc-data-cable","title":"20 AWG 6P Helukabel 21104 PAAR-TRONIC-CY-CY PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M21065_EN_GB_1.pdf?v=1767676312\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 6P Helukabel 21104 PAAR-TRONIC-CY-CY PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a control and signal cable in electronic engineering, measurement and control technology. It provides interference-free transmission of data signals from peripheral equipment to information storage. Excellent connection cable for sound mixers, studio equipment and measurement and control technology. Reliable in process control, machining centers and safety-related systems. These cables with copper screening are ideally suited for interefence-free data and signal transmission for measurement and control technology. EMC = Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e20 AWG 6P Helukabel Paar Tronic CY CY cable, PAAR-TRONIC-CY-CY data cable, Helukabel shielded data cable, Helukabel CY-CY control cable, PVC screened data cable Helukabel, Helukabel instrumentation cable, 20 AWG 6P Pair-screened PVC data cable, Helukabel EMC data cable, Helukabel flexible data cable, 20 AWG 6P Helukabel signal control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 350 V 0.25 - 0.5 mm²: 500 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 1200 V\u003cbr\u003e0.25 - 0.5 mm²: 2000 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e800 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 2400 V\u003cbr\u003e0.25 - 0.5 mm²: 4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003e\u003c\/span\u003eat 800 Hz 0.14 mm²: approx. 147 pF\/m 0.25 mm²: approx. 152 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/screen\u003cbr\u003e\u003c\/strong\u003eat 800 Hz 0.14 mm²: approx. 220 pF\/m 0.25 mm²: approx. 263 pF\/m\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 250 pF\/100m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance \u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12x Outer-Ø\u003cbr\u003efixed 6x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths\u003cbr\u003e• Screening element: pairs, braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• PVC sheath over each screened pair\u003cbr\u003e• Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e20 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 6 x 2 x 0.5\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 16.7\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e201.4\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e319.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62876915597681,"sku":"NNC21104","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_bf00a8a6-fc2f-4b0a-abf6-91bfda7c3114.png?v=1767676691"},{"product_id":"20-awg-8p-helukabel-21105-paar-tronic-cy-cy-pvc-data-cable","title":"20 AWG 8P Helukabel 21105 PAAR-TRONIC-CY-CY PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M21065_EN_GB_1.pdf?v=1767676312\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 8P Helukabel 21105 PAAR-TRONIC-CY-CY PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a control and signal cable in electronic engineering, measurement and control technology. It provides interference-free transmission of data signals from peripheral equipment to information storage. Excellent connection cable for sound mixers, studio equipment and measurement and control technology. Reliable in process control, machining centers and safety-related systems. These cables with copper screening are ideally suited for interefence-free data and signal transmission for measurement and control technology. EMC = Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e20 AWG 8P Helukabel Paar Tronic CY CY cable, PAAR-TRONIC-CY-CY data cable, Helukabel shielded data cable, Helukabel CY-CY control cable, PVC screened data cable Helukabel, Helukabel instrumentation cable, 20 AWG 8P Pair-screened PVC data cable, Helukabel EMC data cable, Helukabel flexible data cable, 20 AWG 8P Helukabel signal control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 350 V 0.25 - 0.5 mm²: 500 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 1200 V\u003cbr\u003e0.25 - 0.5 mm²: 2000 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e800 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 2400 V\u003cbr\u003e0.25 - 0.5 mm²: 4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003e\u003c\/span\u003eat 800 Hz 0.14 mm²: approx. 147 pF\/m 0.25 mm²: approx. 152 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/screen\u003cbr\u003e\u003c\/strong\u003eat 800 Hz 0.14 mm²: approx. 220 pF\/m 0.25 mm²: approx. 263 pF\/m\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 250 pF\/100m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance \u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12x Outer-Ø\u003cbr\u003efixed 6x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths\u003cbr\u003e• Screening element: pairs, braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• PVC sheath over each screened pair\u003cbr\u003e• Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e20 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 8 x 2 x 0.5\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 20.0\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e311.5\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e441.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62876935192945,"sku":"NNC21105","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_bf00a8a6-fc2f-4b0a-abf6-91bfda7c3114.png?v=1767676691"},{"product_id":"20-awg-10p-helukabel-21106-paar-tronic-cy-cy-pvc-data-cable","title":"20 AWG 10P Helukabel 21106 PAAR-TRONIC-CY-CY PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M21065_EN_GB_1.pdf?v=1767676312\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 10P Helukabel 21106 PAAR-TRONIC-CY-CY PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a control and signal cable in electronic engineering, measurement and control technology. It provides interference-free transmission of data signals from peripheral equipment to information storage. Excellent connection cable for sound mixers, studio equipment and measurement and control technology. Reliable in process control, machining centers and safety-related systems. These cables with copper screening are ideally suited for interefence-free data and signal transmission for measurement and control technology. EMC = Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e20 AWG 10P Helukabel Paar Tronic CY CY cable, PAAR-TRONIC-CY-CY data cable, Helukabel shielded data cable, Helukabel CY-CY control cable, PVC screened data cable Helukabel, Helukabel instrumentation cable, 20 AWG 10P Pair-screened PVC data cable, Helukabel EMC data cable, Helukabel flexible data cable, 20 AWG 10P Helukabel signal control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 350 V 0.25 - 0.5 mm²: 500 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 1200 V\u003cbr\u003e0.25 - 0.5 mm²: 2000 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e800 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 2400 V\u003cbr\u003e0.25 - 0.5 mm²: 4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003e\u003c\/span\u003eat 800 Hz 0.14 mm²: approx. 147 pF\/m 0.25 mm²: approx. 152 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/screen\u003cbr\u003e\u003c\/strong\u003eat 800 Hz 0.14 mm²: approx. 220 pF\/m 0.25 mm²: approx. 263 pF\/m\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 250 pF\/100m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance \u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12x Outer-Ø\u003cbr\u003efixed 6x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths\u003cbr\u003e• Screening element: pairs, braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• PVC sheath over each screened pair\u003cbr\u003e• Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e20 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 10 x 2 x 0.5\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 21.9\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e334.5\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e464.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62876944236913,"sku":"NNC21106","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_bf00a8a6-fc2f-4b0a-abf6-91bfda7c3114.png?v=1767676691"},{"product_id":"20-awg-12p-helukabel-21107-paar-tronic-cy-cy-pvc-data-cable","title":"20 AWG 12P Helukabel 21107 PAAR-TRONIC-CY-CY PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M21065_EN_GB_1.pdf?v=1767676312\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 12P Helukabel 21107 PAAR-TRONIC-CY-CY PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a control and signal cable in electronic engineering, measurement and control technology. It provides interference-free transmission of data signals from peripheral equipment to information storage. Excellent connection cable for sound mixers, studio equipment and measurement and control technology. Reliable in process control, machining centers and safety-related systems. These cables with copper screening are ideally suited for interefence-free data and signal transmission for measurement and control technology. EMC = Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e20 AWG 12P Helukabel Paar Tronic CY CY cable, PAAR-TRONIC-CY-CY data cable, Helukabel shielded data cable, Helukabel CY-CY control cable, PVC screened data cable Helukabel, Helukabel instrumentation cable, 20 AWG 12P Pair-screened PVC data cable, Helukabel EMC data cable, Helukabel flexible data cable, 20 AWG 12P Helukabel signal control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 350 V 0.25 - 0.5 mm²: 500 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 1200 V\u003cbr\u003e0.25 - 0.5 mm²: 2000 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e800 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 2400 V\u003cbr\u003e0.25 - 0.5 mm²: 4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003e\u003c\/span\u003eat 800 Hz 0.14 mm²: approx. 147 pF\/m 0.25 mm²: approx. 152 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/screen\u003cbr\u003e\u003c\/strong\u003eat 800 Hz 0.14 mm²: approx. 220 pF\/m 0.25 mm²: approx. 263 pF\/m\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 250 pF\/100m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance \u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12x Outer-Ø\u003cbr\u003efixed 6x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths\u003cbr\u003e• Screening element: pairs, braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• PVC sheath over each screened pair\u003cbr\u003e• Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e20 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 12 x 2 x 0.5\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 22.8 \u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e394.1\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e529.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62876951773553,"sku":"NNC21107","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_bf00a8a6-fc2f-4b0a-abf6-91bfda7c3114.png?v=1767676691"},{"product_id":"20-awg-14p-helukabel-21108-paar-tronic-cy-cy-pvc-data-cable","title":"20 AWG 14P Helukabel 21108 PAAR-TRONIC-CY-CY PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M21065_EN_GB_1.pdf?v=1767676312\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 14P Helukabel 21108 PAAR-TRONIC-CY-CY PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a control and signal cable in electronic engineering, measurement and control technology. It provides interference-free transmission of data signals from peripheral equipment to information storage. Excellent connection cable for sound mixers, studio equipment and measurement and control technology. Reliable in process control, machining centers and safety-related systems. These cables with copper screening are ideally suited for interefence-free data and signal transmission for measurement and control technology. EMC = Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e20 AWG 14P Helukabel Paar Tronic CY CY cable, PAAR-TRONIC-CY-CY data cable, Helukabel shielded data cable, Helukabel CY-CY control cable, PVC screened data cable Helukabel, Helukabel instrumentation cable, 20 AWG 14P Pair-screened PVC data cable, Helukabel EMC data cable, Helukabel flexible data cable, 20 AWG 14P Helukabel signal control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 350 V 0.25 - 0.5 mm²: 500 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 1200 V\u003cbr\u003e0.25 - 0.5 mm²: 2000 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e800 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 2400 V\u003cbr\u003e0.25 - 0.5 mm²: 4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003e\u003c\/span\u003eat 800 Hz 0.14 mm²: approx. 147 pF\/m 0.25 mm²: approx. 152 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/screen\u003cbr\u003e\u003c\/strong\u003eat 800 Hz 0.14 mm²: approx. 220 pF\/m 0.25 mm²: approx. 263 pF\/m\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 250 pF\/100m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance \u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12x Outer-Ø\u003cbr\u003efixed 6x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths\u003cbr\u003e• Screening element: pairs, braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• PVC sheath over each screened pair\u003cbr\u003e• Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e20 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 14 x 2 x 0.5\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 24.1\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e446.0\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e641.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62876958818673,"sku":"NNC21108","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_bf00a8a6-fc2f-4b0a-abf6-91bfda7c3114.png?v=1767676691"},{"product_id":"20-awg-16p-helukabel-21109-paar-tronic-cy-cy-pvc-data-cable","title":"20 AWG 16P Helukabel 21109 PAAR-TRONIC-CY-CY PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M21065_EN_GB_1.pdf?v=1767676312\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 16P Helukabel 21109 PAAR-TRONIC-CY-CY PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a control and signal cable in electronic engineering, measurement and control technology. It provides interference-free transmission of data signals from peripheral equipment to information storage. Excellent connection cable for sound mixers, studio equipment and measurement and control technology. Reliable in process control, machining centers and safety-related systems. These cables with copper screening are ideally suited for interefence-free data and signal transmission for measurement and control technology. EMC = Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e20 AWG 16P Helukabel Paar Tronic CY CY cable, PAAR-TRONIC-CY-CY data cable, Helukabel shielded data cable, Helukabel CY-CY control cable, PVC screened data cable Helukabel, Helukabel instrumentation cable, 20 AWG 16P Pair-screened PVC data cable, Helukabel EMC data cable, Helukabel flexible data cable, 20 AWG 16P Helukabel signal control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 350 V 0.25 - 0.5 mm²: 500 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 1200 V\u003cbr\u003e0.25 - 0.5 mm²: 2000 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e800 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 2400 V\u003cbr\u003e0.25 - 0.5 mm²: 4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003e\u003c\/span\u003eat 800 Hz 0.14 mm²: approx. 147 pF\/m 0.25 mm²: approx. 152 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/screen\u003cbr\u003e\u003c\/strong\u003eat 800 Hz 0.14 mm²: approx. 220 pF\/m 0.25 mm²: approx. 263 pF\/m\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 250 pF\/100m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance \u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12x Outer-Ø\u003cbr\u003efixed 6x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths\u003cbr\u003e• Screening element: pairs, braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• PVC sheath over each screened pair\u003cbr\u003e• Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e20 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 16 x 2 x 0.5\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 25.5\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e501.2\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e694.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62876966650225,"sku":"NNC21109","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_bf00a8a6-fc2f-4b0a-abf6-91bfda7c3114.png?v=1767676691"},{"product_id":"20-awg-24p-helukabel-21110-paar-tronic-cy-cy-pvc-data-cable","title":"20 AWG 24P Helukabel 21110 PAAR-TRONIC-CY-CY PVC Data Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M21065_EN_GB_1.pdf?v=1767676312\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 24P Helukabel 21110 PAAR-TRONIC-CY-CY PVC Data Cable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a control and signal cable in electronic engineering, measurement and control technology. It provides interference-free transmission of data signals from peripheral equipment to information storage. Excellent connection cable for sound mixers, studio equipment and measurement and control technology. Reliable in process control, machining centers and safety-related systems. These cables with copper screening are ideally suited for interefence-free data and signal transmission for measurement and control technology. EMC = Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e20 AWG 24P Helukabel Paar Tronic CY CY cable, PAAR-TRONIC-CY-CY data cable, Helukabel shielded data cable, Helukabel CY-CY control cable, PVC screened data cable Helukabel, Helukabel instrumentation cable, 20 AWG 24P Pair-screened PVC data cable, Helukabel EMC data cable, Helukabel flexible data cable, 20 AWG 24P Helukabel signal control cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC data cable in alignment with DIN VDE 0812\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -5°C to +80°C\u003cbr\u003efixed -40°C to +80°C\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePeak operating voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 350 V 0.25 - 0.5 mm²: 500 V (not for high power current installation purposes)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 1200 V\u003cbr\u003e0.25 - 0.5 mm²: 2000 V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/screen\u003cbr\u003e\u003c\/strong\u003e800 V\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e0.14 mm²: 2400 V\u003cbr\u003e0.25 - 0.5 mm²: 4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/core\u003c\/strong\u003e\u003cspan\u003e \u003cbr\u003e\u003c\/span\u003eat 800 Hz 0.14 mm²: approx. 147 pF\/m 0.25 mm²: approx. 152 pF\/m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutual capacitance core\/screen\u003cbr\u003e\u003c\/strong\u003eat 800 Hz 0.14 mm²: approx. 220 pF\/m 0.25 mm²: approx. 263 pF\/m\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitive coupling k1\u003cbr\u003e\u003c\/strong\u003eat 800 Hz, max. 250 pF\/100m\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance \u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12x Outer-Ø\u003cbr\u003efixed 6x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, 0.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Wire structure:\u003cbr\u003e0.14 mm²: approx. 18 x 0.1 mm\u003cbr\u003e0.25 mm²: approx. 14 x 0.15 mm\u003cbr\u003e0.34 mm²: 7 x 0.25 mm\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN 47100 (paired stranding), colour coded\u003cbr\u003e• x = without protective conductor\u003cbr\u003e• Cores stranded in pairs with optimal lay lengths\u003cbr\u003e• Screening element: pairs, braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• PVC sheath over each screened pair\u003cbr\u003e• Pairs stranded in layers with optimal lay lengths\u003cbr\u003e• Foil wrapping\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in meters\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e• Size : \u003c\/strong\u003e20 AWG\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e• No. cores x cross-sec.mm²:\u003c\/strong\u003e\u003cspan\u003e 24 x 2 x 0.5\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Outer Ø. mm approx:\u003c\/strong\u003e\u003cspan\u003e 32.1\u003cbr\u003e\u003cstrong\u003e• Cu factor per km: \u003c\/strong\u003e712.4\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e• Weight approx kg\/km:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e930.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":62876975563121,"sku":"NNC21110","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_bf00a8a6-fc2f-4b0a-abf6-91bfda7c3114.png?v=1767676691"}],"url":"https:\/\/nassaunationalcable.com\/collections\/helukabel-paar-tronic-cy-cy-pvc-data-cable.oembed?page=2","provider":"NassauNationalCable","version":"1.0","type":"link"}