{"title":"HELUKABEL JZ-602-CY \/ OZ-602-CY PVC Control and Connection Cable","description":"\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003eHELUKABEL JZ-602-CY \/ OZ-602-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e","products":[{"product_id":"helukabel-jz-602-cy-oz-602-cy-pvc-control-and-connection-cable","title":"HELUKABEL JZ-602-CY \/ OZ-602-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M82990_EN_GB_1.pdf?v=1778137952\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003eHELUKABEL JZ-602-CY \/ OZ-602-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUL\/CSA approved, flexible control cable (up to 600 V) for machine, tool and plant construction. Suitable for medium mechanical stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Designed for export-oriented mechanical engineers, specifically in the USA and Canada. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-start=\"132\" data-end=\"162\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003eShielded Control Cable CY PVC Control Cable Flexible EMC Control Cable Shielded Connection Cable Industrial Automation Cable PVC Flexible Control Cable Braided Shield Control Cable Tinned Copper Shielded Cable UL\/CSA Approved Control Cable 600V Flexible Control Cable Oil-Resistant Control Cable Machine Tool Control Cable EMC Preferred Type Cable Flexible Signal \u0026amp; Control Cable Multi-Core Shielded Cable Grey Jacket Control Cable JZ-602-CY Grounded Control Cable OZ-602-CY Ungrounded Control Cable Industrial Connection Cable Flexible Power and Control Cable\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable acc. to UL-Std. 758 (AWM) Style 2587, CSA-Std. C22.2 No. 210 - AWM I\/II A\/B\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -10°C to +90°C\u003cbr\u003efixed -40°C to +90°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eUL (AWM) AC 600 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e3000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e6000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 10x Outer-Ø\u003cbr\u003efixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to UL-Std. 758 (AWM) Style 11008, CSA-Std. C22.2 No. 210\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003e x = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2, UL VW-1, CSA FT1\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are\u003cbr\u003eapproximated, and are for reference only\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63567904244081,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_9e2d6b2e-ddce-46c5-90d0-b280da8bfbd0.png?v=1778137831"},{"product_id":"20-awg-2c-helukabel-82990-oz-602-cy-pvc-control-and-connection-cable","title":"20 AWG 2C HELUKABEL 82990 OZ-602-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M82990_EN_GB_1.pdf?v=1778137952\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 2C HELUKABEL 82990 OZ-602-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUL\/CSA approved, flexible control cable (up to 600 V) for machine, tool and plant construction. Suitable for medium mechanical stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Designed for export-oriented mechanical engineers, specifically in the USA and Canada. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e20 AWG 2C Shielded Control Cable CY PVC Control Cable Flexible EMC Control Cable Shielded Connection Cable Industrial Automation Cable PVC Flexible Control Cable Braided Shield Control Cable Tinned 20 AWG 2C Copper Shielded Cable UL\/CSA Approved Control Cable 600V Flexible Control Cable Oil-Resistant Control Cable Machine Tool Control Cable EMC Preferred Type Cable Flexible Signal \u0026amp; Control Cable Multi-Core Shielded Cable Grey Jacket 20 AWG 2C Control Cable Grounded Control Cable OZ-602-CY Ungrounded Control Cable Industrial Connection Cable Flexible Power and Control Cable\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable acc. to UL-Std. 758 (AWM) Style 2587, CSA-Std. C22.2 No. 210 - AWM I\/II A\/B\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -10°C to +90°C\u003cbr\u003efixed -40°C to +90°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eUL (AWM) AC 600 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e3000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e6000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 10x Outer-Ø\u003cbr\u003efixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to UL-Std. 758 (AWM) Style 11008, CSA-Std. C22.2 No. 210\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003e x = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2, UL VW-1, CSA FT1\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are\u003cbr\u003eapproximated, and are for reference only\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size :\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e20 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 2 x 0.5\u003cb\u003e\u003cbr\u003e• Outer-Ø min - max mm:\u003c\/b\u003e 7.0 \u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e35.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx: \u003c\/b\u003e93.0\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63567967060337,"sku":"NNC82990","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design-Photoroom_1200f187-f885-474e-9d0c-e6a81e688b85.png?v=1778138621"},{"product_id":"20-awg-3c-helukabel-82991-jz-602-cy-pvc-control-and-connection-cable","title":"20 AWG 3C HELUKABEL 82991 JZ-602-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M82990_EN_GB_1.pdf?v=1778137952\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 3C HELUKABEL 82991 JZ-602-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUL\/CSA approved, flexible control cable (up to 600 V) for machine, tool and plant construction. Suitable for medium mechanical stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Designed for export-oriented mechanical engineers, specifically in the USA and Canada. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e20 AWG 3C Shielded Control Cable CY PVC Control Cable Flexible EMC Control Cable Shielded Connection Cable Industrial Automation Cable PVC Flexible Control Cable Braided Shield Control Cable Tinned 20 AWG 3C Copper Shielded Cable UL\/CSA Approved Control Cable 600V Flexible Control Cable Oil-Resistant Control Cable Machine Tool Control Cable EMC Preferred Type Cable Flexible Signal \u0026amp; Control Cable Multi-Core Shielded Cable Grey Jacket 20 AWG 3C Control Cable Grounded Control Cable JZ-602-CY Ungrounded Control Cable Industrial Connection Cable Flexible Power and Control Cable\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable acc. to UL-Std. 758 (AWM) Style 2587, CSA-Std. C22.2 No. 210 - AWM I\/II A\/B\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -10°C to +90°C\u003cbr\u003efixed -40°C to +90°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eUL (AWM) AC 600 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e3000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e6000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 10x Outer-Ø\u003cbr\u003efixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to UL-Std. 758 (AWM) Style 11008, CSA-Std. C22.2 No. 210\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003e x = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2, UL VW-1, CSA FT1\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are\u003cbr\u003eapproximated, and are for reference only\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size :\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e20 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 3 G 0.5\u003cb\u003e\u003cbr\u003e• Outer-Ø min - max mm:\u003c\/b\u003e 7.3\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e42.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx: \u003c\/b\u003e124.0\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63568020668785,"sku":"NNC82991","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_69c7aee1-e54f-491f-87d8-d32860c7f2db.png?v=1778138954"},{"product_id":"20-awg-4c-helukabel-82992-jz-602-cy-pvc-control-and-connection-cable","title":"20 AWG 4C HELUKABEL 82992 JZ-602-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M82990_EN_GB_1.pdf?v=1778137952\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 4C HELUKABEL 82992 JZ-602-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUL\/CSA approved, flexible control cable (up to 600 V) for machine, tool and plant construction. Suitable for medium mechanical stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Designed for export-oriented mechanical engineers, specifically in the USA and Canada. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e20 AWG 4C Shielded Control Cable CY PVC Control Cable Flexible EMC Control Cable Shielded Connection Cable Industrial Automation Cable PVC Flexible Control Cable Braided Shield Control Cable Tinned 20 AWG 4C Copper Shielded Cable UL\/CSA Approved Control Cable 600V Flexible Control Cable Oil-Resistant Control Cable Machine Tool Control Cable EMC Preferred Type Cable Flexible Signal \u0026amp; Control Cable Multi-Core Shielded Cable Grey Jacket 20 AWG 4C Control Cable Grounded Control Cable JZ-602-CY Ungrounded Control Cable Industrial Connection Cable Flexible Power and Control Cable\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable acc. to UL-Std. 758 (AWM) Style 2587, CSA-Std. C22.2 No. 210 - AWM I\/II A\/B\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -10°C to +90°C\u003cbr\u003efixed -40°C to +90°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eUL (AWM) AC 600 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e3000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e6000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 10x Outer-Ø\u003cbr\u003efixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to UL-Std. 758 (AWM) Style 11008, CSA-Std. C22.2 No. 210\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003e x = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2, UL VW-1, CSA FT1\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are\u003cbr\u003eapproximated, and are for reference only\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size :\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e20 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 4 G 0.5\u003cb\u003e\u003cbr\u003e• Outer-Ø min - max mm:\u003c\/b\u003e 7.7\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e47.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx: \u003c\/b\u003e133.0\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63568029581681,"sku":"NNC82992","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_69c7aee1-e54f-491f-87d8-d32860c7f2db.png?v=1778138954"},{"product_id":"20-awg-5c-helukabel-82993-jz-602-cy-pvc-control-and-connection-cable","title":"20 AWG 5C HELUKABEL 82993 JZ-602-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M82990_EN_GB_1.pdf?v=1778137952\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 5C HELUKABEL 82993 JZ-602-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUL\/CSA approved, flexible control cable (up to 600 V) for machine, tool and plant construction. Suitable for medium mechanical stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Designed for export-oriented mechanical engineers, specifically in the USA and Canada. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e20 AWG 5C Shielded Control Cable CY PVC Control Cable Flexible EMC Control Cable Shielded Connection Cable Industrial Automation Cable PVC Flexible Control Cable Braided Shield Control Cable Tinned 20 AWG 5C Copper Shielded Cable UL\/CSA Approved Control Cable 600V Flexible Control Cable Oil-Resistant Control Cable Machine Tool Control Cable EMC Preferred Type Cable Flexible Signal \u0026amp; Control Cable Multi-Core Shielded Cable Grey Jacket 20 AWG 5C Control Cable Grounded Control Cable JZ-602-CY Ungrounded Control Cable Industrial Connection Cable Flexible Power and Control Cable\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable acc. to UL-Std. 758 (AWM) Style 2587, CSA-Std. C22.2 No. 210 - AWM I\/II A\/B\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -10°C to +90°C\u003cbr\u003efixed -40°C to +90°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eUL (AWM) AC 600 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e3000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e6000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 10x Outer-Ø\u003cbr\u003efixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to UL-Std. 758 (AWM) Style 11008, CSA-Std. C22.2 No. 210\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003e x = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2, UL VW-1, CSA FT1\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are\u003cbr\u003eapproximated, and are for reference only\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size :\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e20 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 5 G 0.5\u003cb\u003e\u003cbr\u003e• Outer-Ø min - max mm:\u003c\/b\u003e 8.2\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e56.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx: \u003c\/b\u003e153.0\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63568044786033,"sku":"NNC82993","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_69c7aee1-e54f-491f-87d8-d32860c7f2db.png?v=1778138954"},{"product_id":"20-awg-7c-helukabel-82994-jz-602-cy-pvc-control-and-connection-cable","title":"20 AWG 7C HELUKABEL 82994 JZ-602-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M82990_EN_GB_1.pdf?v=1778137952\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 7C HELUKABEL 82994 JZ-602-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUL\/CSA approved, flexible control cable (up to 600 V) for machine, tool and plant construction. Suitable for medium mechanical stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Designed for export-oriented mechanical engineers, specifically in the USA and Canada. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e20 AWG 7C Shielded Control Cable CY PVC Control Cable Flexible EMC Control Cable Shielded Connection Cable Industrial Automation Cable PVC Flexible Control Cable Braided Shield Control Cable Tinned 20 AWG 7C Copper Shielded Cable UL\/CSA Approved Control Cable 600V Flexible Control Cable Oil-Resistant Control Cable Machine Tool Control Cable EMC Preferred Type Cable Flexible Signal \u0026amp; Control Cable Multi-Core Shielded Cable Grey Jacket 20 AWG 7C Control Cable Grounded Control Cable JZ-602-CY Ungrounded Control Cable Industrial Connection Cable Flexible Power and Control Cable\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable acc. to UL-Std. 758 (AWM) Style 2587, CSA-Std. C22.2 No. 210 - AWM I\/II A\/B\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -10°C to +90°C\u003cbr\u003efixed -40°C to +90°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eUL (AWM) AC 600 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e3000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e6000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 10x Outer-Ø\u003cbr\u003efixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to UL-Std. 758 (AWM) Style 11008, CSA-Std. C22.2 No. 210\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003e x = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2, UL VW-1, CSA FT1\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are\u003cbr\u003eapproximated, and are for reference only\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size :\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e20 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 7 G 0.5\u003cb\u003e\u003cbr\u003e• Outer-Ø min - max mm:\u003c\/b\u003e 8.9\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e69.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx: \u003c\/b\u003e191.0\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63568057401713,"sku":"NNC82994","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_69c7aee1-e54f-491f-87d8-d32860c7f2db.png?v=1778138954"},{"product_id":"20-awg-9c-helukabel-82995-jz-602-cy-pvc-control-and-connection-cable","title":"20 AWG 9C HELUKABEL 82995 JZ-602-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M82990_EN_GB_1.pdf?v=1778137952\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 9C HELUKABEL 82995 JZ-602-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUL\/CSA approved, flexible control cable (up to 600 V) for machine, tool and plant construction. Suitable for medium mechanical stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Designed for export-oriented mechanical engineers, specifically in the USA and Canada. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e20 AWG 9C Shielded Control Cable CY PVC Control Cable Flexible EMC Control Cable Shielded Connection Cable Industrial Automation Cable PVC Flexible Control Cable Braided Shield Control Cable Tinned 20 AWG 9C Copper Shielded Cable UL\/CSA Approved Control Cable 600V Flexible Control Cable Oil-Resistant Control Cable Machine Tool Control Cable EMC Preferred Type Cable Flexible Signal \u0026amp; Control Cable Multi-Core Shielded Cable Grey Jacket 20 AWG 9C Control Cable Grounded Control Cable JZ-602-CY Ungrounded Control Cable Industrial Connection Cable Flexible Power and Control Cable\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable acc. to UL-Std. 758 (AWM) Style 2587, CSA-Std. C22.2 No. 210 - AWM I\/II A\/B\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -10°C to +90°C\u003cbr\u003efixed -40°C to +90°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eUL (AWM) AC 600 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e3000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e6000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 10x Outer-Ø\u003cbr\u003efixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to UL-Std. 758 (AWM) Style 11008, CSA-Std. C22.2 No. 210\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003e x = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2, UL VW-1, CSA FT1\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are\u003cbr\u003eapproximated, and are for reference only\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size :\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e20 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 9 G 0.5\u003cb\u003e\u003cbr\u003e• Outer-Ø min - max mm:\u003c\/b\u003e 10.0\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 87.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx: \u003c\/b\u003e243.0\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63568075227505,"sku":"NNC82995","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_69c7aee1-e54f-491f-87d8-d32860c7f2db.png?v=1778138954"},{"product_id":"20-awg-12c-helukabel-82996-jz-602-cy-pvc-control-and-connection-cable","title":"20 AWG 12C HELUKABEL 82996 JZ-602-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M82990_EN_GB_1.pdf?v=1778137952\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 12C HELUKABEL 82996 JZ-602-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUL\/CSA approved, flexible control cable (up to 600 V) for machine, tool and plant construction. Suitable for medium mechanical stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Designed for export-oriented mechanical engineers, specifically in the USA and Canada. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e20 AWG 12C Shielded Control Cable CY PVC Control Cable Flexible EMC Control Cable Shielded Connection Cable Industrial Automation Cable PVC Flexible Control Cable Braided Shield Control Cable Tinned 20 AWG 12C Copper Shielded Cable UL\/CSA Approved Control Cable 600V Flexible Control Cable Oil-Resistant Control Cable Machine Tool Control Cable EMC Preferred Type Cable Flexible Signal \u0026amp; Control Cable Multi-Core Shielded Cable Grey Jacket 20 AWG 12C Control Cable Grounded Control Cable JZ-602-CY Ungrounded Control Cable Industrial Connection Cable Flexible Power and Control Cable\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable acc. to UL-Std. 758 (AWM) Style 2587, CSA-Std. C22.2 No. 210 - AWM I\/II A\/B\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -10°C to +90°C\u003cbr\u003efixed -40°C to +90°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eUL (AWM) AC 600 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e3000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e6000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 10x Outer-Ø\u003cbr\u003efixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to UL-Std. 758 (AWM) Style 11008, CSA-Std. C22.2 No. 210\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003e x = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2, UL VW-1, CSA FT1\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are\u003cbr\u003eapproximated, and are for reference only\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size :\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e20 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 12 G 0.5\u003cb\u003e\u003cbr\u003e• Outer-Ø min - max mm:\u003c\/b\u003e 11.0\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 108.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx: \u003c\/b\u003e322.0\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63568145187185,"sku":"NNC82996","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_69c7aee1-e54f-491f-87d8-d32860c7f2db.png?v=1778138954"},{"product_id":"20-awg-18c-helukabel-82997-jz-602-cy-pvc-control-and-connection-cable","title":"20 AWG 18C HELUKABEL 82997 JZ-602-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M82990_EN_GB_1.pdf?v=1778137952\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 18C HELUKABEL 82997 JZ-602-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUL\/CSA approved, flexible control cable (up to 600 V) for machine, tool and plant construction. Suitable for medium mechanical stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Designed for export-oriented mechanical engineers, specifically in the USA and Canada. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e20 AWG 18C Shielded Control Cable CY PVC Control Cable Flexible EMC Control Cable Shielded Connection Cable Industrial Automation Cable PVC Flexible Control Cable Braided Shield Control Cable Tinned 20 AWG 18C Copper Shielded Cable UL\/CSA Approved Control Cable 600V Flexible Control Cable Oil-Resistant Control Cable Machine Tool Control Cable EMC Preferred Type Cable Flexible Signal \u0026amp; Control Cable Multi-Core Shielded Cable Grey Jacket 20 AWG 18C Control Cable Grounded Control Cable JZ-602-CY Ungrounded Control Cable Industrial Connection Cable Flexible Power and Control Cable\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable acc. to UL-Std. 758 (AWM) Style 2587, CSA-Std. C22.2 No. 210 - AWM I\/II A\/B\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -10°C to +90°C\u003cbr\u003efixed -40°C to +90°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eUL (AWM) AC 600 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e3000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e6000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 10x Outer-Ø\u003cbr\u003efixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to UL-Std. 758 (AWM) Style 11008, CSA-Std. C22.2 No. 210\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003e x = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2, UL VW-1, CSA FT1\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are\u003cbr\u003eapproximated, and are for reference only\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size :\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e20 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 18 G 0.5\u003cb\u003e\u003cbr\u003e• Outer-Ø min - max mm:\u003c\/b\u003e 13.1\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 145.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx: \u003c\/b\u003e374.0\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63568151609713,"sku":"NNC82997","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_69c7aee1-e54f-491f-87d8-d32860c7f2db.png?v=1778138954"},{"product_id":"20-awg-25c-helukabel-82998-jz-602-cy-pvc-control-and-connection-cable","title":"20 AWG 25C HELUKABEL 82998 JZ-602-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M82990_EN_GB_1.pdf?v=1778137952\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 25C HELUKABEL 82998 JZ-602-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUL\/CSA approved, flexible control cable (up to 600 V) for machine, tool and plant construction. Suitable for medium mechanical stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Designed for export-oriented mechanical engineers, specifically in the USA and Canada. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e20 AWG 25C Shielded Control Cable CY PVC Control Cable Flexible EMC Control Cable Shielded Connection Cable Industrial Automation Cable PVC Flexible Control Cable Braided Shield Control Cable Tinned 20 AWG 25C Copper Shielded Cable UL\/CSA Approved Control Cable 600V Flexible Control Cable Oil-Resistant Control Cable Machine Tool Control Cable EMC Preferred Type Cable Flexible Signal \u0026amp; Control Cable Multi-Core Shielded Cable Grey Jacket 20 AWG 25C Control Cable Grounded Control Cable JZ-602-CY Ungrounded Control Cable Industrial Connection Cable Flexible Power and Control Cable\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable acc. to UL-Std. 758 (AWM) Style 2587, CSA-Std. C22.2 No. 210 - AWM I\/II A\/B\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -10°C to +90°C\u003cbr\u003efixed -40°C to +90°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eUL (AWM) AC 600 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e3000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e6000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 10x Outer-Ø\u003cbr\u003efixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to UL-Std. 758 (AWM) Style 11008, CSA-Std. C22.2 No. 210\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003e x = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2, UL VW-1, CSA FT1\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are\u003cbr\u003eapproximated, and are for reference only\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size :\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e20 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 25 G 0.5\u003cb\u003e\u003cbr\u003e• Outer-Ø min - max mm:\u003c\/b\u003e 15.0\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 240.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx: \u003c\/b\u003e436.0\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63568163537265,"sku":"NNC82998","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_69c7aee1-e54f-491f-87d8-d32860c7f2db.png?v=1778138954"},{"product_id":"20-awg-34c-helukabel-82999-jz-602-cy-pvc-control-and-connection-cable","title":"20 AWG 34C HELUKABEL 82999 JZ-602-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M82990_EN_GB_1.pdf?v=1778137952\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 34C HELUKABEL 82999 JZ-602-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUL\/CSA approved, flexible control cable (up to 600 V) for machine, tool and plant construction. Suitable for medium mechanical stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Designed for export-oriented mechanical engineers, specifically in the USA and Canada. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e20 AWG 34C Shielded Control Cable CY PVC Control Cable Flexible EMC Control Cable Shielded Connection Cable Industrial Automation Cable PVC Flexible Control Cable Braided Shield Control Cable Tinned 20 AWG 34C Copper Shielded Cable UL\/CSA Approved Control Cable 600V Flexible Control Cable Oil-Resistant Control Cable Machine Tool Control Cable EMC Preferred Type Cable Flexible Signal \u0026amp; Control Cable Multi-Core Shielded Cable Grey Jacket 20 AWG 34C Control Cable Grounded Control Cable JZ-602-CY Ungrounded Control Cable Industrial Connection Cable Flexible Power and Control Cable\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable acc. to UL-Std. 758 (AWM) Style 2587, CSA-Std. C22.2 No. 210 - AWM I\/II A\/B\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -10°C to +90°C\u003cbr\u003efixed -40°C to +90°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eUL (AWM) AC 600 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e3000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e6000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 10x Outer-Ø\u003cbr\u003efixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to UL-Std. 758 (AWM) Style 11008, CSA-Std. C22.2 No. 210\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003e x = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2, UL VW-1, CSA FT1\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are\u003cbr\u003eapproximated, and are for reference only\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size :\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e20 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 34 G 0.5\u003cb\u003e\u003cbr\u003e• Outer-Ø min - max mm:\u003c\/b\u003e 16.9\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 312.0 \u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx: \u003c\/b\u003e560.0\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63568655384945,"sku":"NNC82999","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_69c7aee1-e54f-491f-87d8-d32860c7f2db.png?v=1778138954"},{"product_id":"20-awg-41c-helukabel-83000-jz-602-cy-pvc-control-and-connection-cable","title":"20 AWG 41C HELUKABEL 83000 JZ-602-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M82990_EN_GB_1.pdf?v=1778137952\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 41C HELUKABEL 83000 JZ-602-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUL\/CSA approved, flexible control cable (up to 600 V) for machine, tool and plant construction. Suitable for medium mechanical stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Designed for export-oriented mechanical engineers, specifically in the USA and Canada. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e20 AWG 41C Shielded Control Cable CY PVC Control Cable Flexible EMC Control Cable Shielded Connection Cable Industrial Automation Cable PVC Flexible Control Cable Braided Shield Control Cable Tinned 20 AWG 41C Copper Shielded Cable UL\/CSA Approved Control Cable 600V Flexible Control Cable Oil-Resistant Control Cable Machine Tool Control Cable EMC Preferred Type Cable Flexible Signal \u0026amp; Control Cable Multi-Core Shielded Cable Grey Jacket 20 AWG 41C Control Cable Grounded Control Cable JZ-602-CY Ungrounded Control Cable Industrial Connection Cable Flexible Power and Control Cable\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable acc. to UL-Std. 758 (AWM) Style 2587, CSA-Std. C22.2 No. 210 - AWM I\/II A\/B\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -10°C to +90°C\u003cbr\u003efixed -40°C to +90°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eUL (AWM) AC 600 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e3000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e6000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 10x Outer-Ø\u003cbr\u003efixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to UL-Std. 758 (AWM) Style 11008, CSA-Std. C22.2 No. 210\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003e x = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2, UL VW-1, CSA FT1\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are\u003cbr\u003eapproximated, and are for reference only\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size :\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e20 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 41 G 0.5\u003cb\u003e\u003cbr\u003e• Outer-Ø min - max mm:\u003c\/b\u003e 18.4\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 348.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx: \u003c\/b\u003e663.0\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63568663839089,"sku":"NNC83000","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_69c7aee1-e54f-491f-87d8-d32860c7f2db.png?v=1778138954"},{"product_id":"18-awg-2c-helukabel-82979-oz-602-cy-pvc-control-and-connection-cable","title":"18 AWG 2C HELUKABEL 82979 OZ-602-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M82990_EN_GB_1.pdf?v=1778137952\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e18 AWG 2C HELUKABEL 82979 OZ-602-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUL\/CSA approved, flexible control cable (up to 600 V) for machine, tool and plant construction. Suitable for medium mechanical stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Designed for export-oriented mechanical engineers, specifically in the USA and Canada. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e18 AWG 2C Shielded Control Cable CY PVC Control Cable Flexible EMC Control Cable Shielded Connection Cable Industrial Automation Cable PVC Flexible Control Cable Braided Shield Control Cable Tinned 18 AWG 2C Copper Shielded Cable UL\/CSA Approved Control Cable 600V Flexible Control Cable Oil-Resistant Control Cable Machine Tool Control Cable EMC Preferred Type Cable Flexible Signal \u0026amp; Control Cable Multi-Core Shielded Cable Grey Jacket 18 AWG 2C Control Cable Grounded Control Cable JZ-602-CY Ungrounded Control Cable Industrial Connection Cable Flexible Power and Control Cable\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable acc. to UL-Std. 758 (AWM) Style 2587, CSA-Std. C22.2 No. 210 - AWM I\/II A\/B\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -10°C to +90°C\u003cbr\u003efixed -40°C to +90°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eUL (AWM) AC 600 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e3000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e6000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 10x Outer-Ø\u003cbr\u003efixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to UL-Std. 758 (AWM) Style 11008, CSA-Std. C22.2 No. 210\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003e x = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2, UL VW-1, CSA FT1\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are\u003cbr\u003eapproximated, and are for reference only\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size :\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e18 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 2 x 1\u003cb\u003e\u003cbr\u003e• Outer-Ø min - max mm:\u003c\/b\u003e 7.8\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 50.0 \u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx: \u003c\/b\u003e107.0\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63568673440113,"sku":"NNC82979","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design-Photoroom_8f708f31-af7d-42c0-8fc0-820ee253b6cd.png?v=1778149452"},{"product_id":"18-awg-3c-helukabel-82980-jz-602-cy-pvc-control-and-connection-cable","title":"18 AWG 3C HELUKABEL 82980 JZ-602-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M82990_EN_GB_1.pdf?v=1778137952\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e18 AWG 3C HELUKABEL 82980 JZ-602-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUL\/CSA approved, flexible control cable (up to 600 V) for machine, tool and plant construction. Suitable for medium mechanical stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Designed for export-oriented mechanical engineers, specifically in the USA and Canada. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e18 AWG 3C Shielded Control Cable CY PVC Control Cable Flexible EMC Control Cable Shielded Connection Cable Industrial Automation Cable PVC Flexible Control Cable Braided Shield Control Cable Tinned 18 AWG 3C Copper Shielded Cable UL\/CSA Approved Control Cable 600V Flexible Control Cable Oil-Resistant Control Cable Machine Tool Control Cable EMC Preferred Type Cable Flexible Signal \u0026amp; Control Cable Multi-Core Shielded Cable Grey Jacket 18 AWG 3C Control Cable Grounded Control Cable JZ-602-CY Ungrounded Control Cable Industrial Connection Cable Flexible Power and Control Cable\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable acc. to UL-Std. 758 (AWM) Style 2587, CSA-Std. C22.2 No. 210 - AWM I\/II A\/B\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -10°C to +90°C\u003cbr\u003efixed -40°C to +90°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eUL (AWM) AC 600 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e3000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e6000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 10x Outer-Ø\u003cbr\u003efixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to UL-Std. 758 (AWM) Style 11008, CSA-Std. C22.2 No. 210\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003e x = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2, UL VW-1, CSA FT1\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are\u003cbr\u003eapproximated, and are for reference only\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size :\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e18 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 3 G 1\u003cb\u003e\u003cbr\u003e• Outer-Ø min - max mm:\u003c\/b\u003e 8.2\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 60.0 \u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx: \u003c\/b\u003e130.0\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63568680452465,"sku":"NNC82980","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_73f2a470-8403-4839-8108-b3f08f57c71a.png?v=1778149617"},{"product_id":"18-awg-4c-helukabel-82981-jz-602-cy-pvc-control-and-connection-cable","title":"18 AWG 4C HELUKABEL 82981 JZ-602-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M82990_EN_GB_1.pdf?v=1778137952\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e18 AWG 4C HELUKABEL 82981 JZ-602-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUL\/CSA approved, flexible control cable (up to 600 V) for machine, tool and plant construction. Suitable for medium mechanical stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Designed for export-oriented mechanical engineers, specifically in the USA and Canada. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e18 AWG 4C Shielded Control Cable CY PVC Control Cable Flexible EMC Control Cable Shielded Connection Cable Industrial Automation Cable PVC Flexible Control Cable Braided Shield Control Cable Tinned 18 AWG 4C Copper Shielded Cable UL\/CSA Approved Control Cable 600V Flexible Control Cable Oil-Resistant Control Cable Machine Tool Control Cable EMC Preferred Type Cable Flexible Signal \u0026amp; Control Cable Multi-Core Shielded Cable Grey Jacket 18 AWG 4C Control Cable Grounded Control Cable JZ-602-CY Ungrounded Control Cable Industrial Connection Cable Flexible Power and Control Cable\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable acc. to UL-Std. 758 (AWM) Style 2587, CSA-Std. C22.2 No. 210 - AWM I\/II A\/B\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -10°C to +90°C\u003cbr\u003efixed -40°C to +90°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eUL (AWM) AC 600 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e3000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e6000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 10x Outer-Ø\u003cbr\u003efixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to UL-Std. 758 (AWM) Style 11008, CSA-Std. C22.2 No. 210\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003e x = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2, UL VW-1, CSA FT1\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are\u003cbr\u003eapproximated, and are for reference only\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size :\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e18 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 4 G 1\u003cb\u003e\u003cbr\u003e• Outer-Ø min - max mm:\u003c\/b\u003e 8.9\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 71.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx: \u003c\/b\u003e155.0\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63574166700401,"sku":"NNC82981","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_73f2a470-8403-4839-8108-b3f08f57c71a.png?v=1778149617"},{"product_id":"18-awg-5c-helukabel-82982-jz-602-cy-pvc-control-and-connection-cable","title":"18 AWG 5C HELUKABEL 82982 JZ-602-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M82990_EN_GB_1.pdf?v=1778137952\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e18 AWG 5C HELUKABEL 82982 JZ-602-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUL\/CSA approved, flexible control cable (up to 600 V) for machine, tool and plant construction. Suitable for medium mechanical stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Designed for export-oriented mechanical engineers, specifically in the USA and Canada. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e18 AWG 5C Shielded Control Cable CY PVC Control Cable Flexible EMC Control Cable Shielded Connection Cable Industrial Automation Cable PVC Flexible Control Cable Braided Shield Control Cable Tinned 18 AWG 5C Copper Shielded Cable UL\/CSA Approved Control Cable 600V Flexible Control Cable Oil-Resistant Control Cable Machine Tool Control Cable EMC Preferred Type Cable Flexible Signal \u0026amp; Control Cable Multi-Core Shielded Cable Grey Jacket 18 AWG 5C Control Cable Grounded Control Cable JZ-602-CY Ungrounded Control Cable Industrial Connection Cable Flexible Power and Control Cable\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable acc. to UL-Std. 758 (AWM) Style 2587, CSA-Std. C22.2 No. 210 - AWM I\/II A\/B\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -10°C to +90°C\u003cbr\u003efixed -40°C to +90°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eUL (AWM) AC 600 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e3000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e6000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 10x Outer-Ø\u003cbr\u003efixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to UL-Std. 758 (AWM) Style 11008, CSA-Std. C22.2 No. 210\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003e x = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2, UL VW-1, CSA FT1\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are\u003cbr\u003eapproximated, and are for reference only\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size :\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e18 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 5 G 1\u003cb\u003e\u003cbr\u003e• Outer-Ø min - max mm:\u003c\/b\u003e 9.5\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 88.0 \u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx: \u003c\/b\u003e181.0\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63574178464113,"sku":"NNC82982","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_73f2a470-8403-4839-8108-b3f08f57c71a.png?v=1778149617"},{"product_id":"18-awg-7c-helukabel-82983-jz-602-cy-pvc-control-and-connection-cable","title":"18 AWG 7C HELUKABEL 82983 JZ-602-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M82990_EN_GB_1.pdf?v=1778137952\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e18 AWG 7C HELUKABEL 82983 JZ-602-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUL\/CSA approved, flexible control cable (up to 600 V) for machine, tool and plant construction. Suitable for medium mechanical stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Designed for export-oriented mechanical engineers, specifically in the USA and Canada. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e18 AWG 7C Shielded Control Cable CY PVC Control Cable Flexible EMC Control Cable Shielded Connection Cable Industrial Automation Cable PVC Flexible Control Cable Braided Shield Control Cable Tinned 18 AWG 7C Copper Shielded Cable UL\/CSA Approved Control Cable 600V Flexible Control Cable Oil-Resistant Control Cable Machine Tool Control Cable EMC Preferred Type Cable Flexible Signal \u0026amp; Control Cable Multi-Core Shielded Cable Grey Jacket 18 AWG 7C Control Cable Grounded Control Cable JZ-602-CY Ungrounded Control Cable Industrial Connection Cable Flexible Power and Control Cable\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable acc. to UL-Std. 758 (AWM) Style 2587, CSA-Std. C22.2 No. 210 - AWM I\/II A\/B\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -10°C to +90°C\u003cbr\u003efixed -40°C to +90°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eUL (AWM) AC 600 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e3000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e6000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 10x Outer-Ø\u003cbr\u003efixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to UL-Std. 758 (AWM) Style 11008, CSA-Std. C22.2 No. 210\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003e x = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2, UL VW-1, CSA FT1\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are\u003cbr\u003eapproximated, and are for reference only\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size :\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e18 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 7 G 1\u003cb\u003e\u003cbr\u003e• Outer-Ø min - max mm:\u003c\/b\u003e 10.1\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 111.0 \u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx: \u003c\/b\u003e209.0\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63574181871985,"sku":"NNC82983","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_73f2a470-8403-4839-8108-b3f08f57c71a.png?v=1778149617"},{"product_id":"18-awg-9c-helukabel-82984-jz-602-cy-pvc-control-and-connection-cable","title":"18 AWG 9C HELUKABEL 82984 JZ-602-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M82990_EN_GB_1.pdf?v=1778137952\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e18 AWG 9C HELUKABEL 82984 JZ-602-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUL\/CSA approved, flexible control cable (up to 600 V) for machine, tool and plant construction. Suitable for medium mechanical stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Designed for export-oriented mechanical engineers, specifically in the USA and Canada. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e18 AWG 9C Shielded Control Cable CY PVC Control Cable Flexible EMC Control Cable Shielded Connection Cable Industrial Automation Cable PVC Flexible Control Cable Braided Shield Control Cable Tinned 18 AWG 9C Copper Shielded Cable UL\/CSA Approved Control Cable 600V Flexible Control Cable Oil-Resistant Control Cable Machine Tool Control Cable EMC Preferred Type Cable Flexible Signal \u0026amp; Control Cable Multi-Core Shielded Cable Grey Jacket 18 AWG 9C Control Cable Grounded Control Cable JZ-602-CY Ungrounded Control Cable Industrial Connection Cable Flexible Power and Control Cable\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable acc. to UL-Std. 758 (AWM) Style 2587, CSA-Std. C22.2 No. 210 - AWM I\/II A\/B\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -10°C to +90°C\u003cbr\u003efixed -40°C to +90°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eUL (AWM) AC 600 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e3000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e6000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 10x Outer-Ø\u003cbr\u003efixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to UL-Std. 758 (AWM) Style 11008, CSA-Std. C22.2 No. 210\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003e x = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2, UL VW-1, CSA FT1\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are\u003cbr\u003eapproximated, and are for reference only\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size :\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e18 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 9 G 1\u003cb\u003e\u003cbr\u003e• Outer-Ø min - max mm:\u003c\/b\u003e 11.8\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 139.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx: \u003c\/b\u003e321.0\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63574184526193,"sku":"NNC82984","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_73f2a470-8403-4839-8108-b3f08f57c71a.png?v=1778149617"},{"product_id":"18-awg-12c-helukabel-82985-jz-602-cy-pvc-control-and-connection-cable","title":"18 AWG 12C HELUKABEL 82985 JZ-602-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M82990_EN_GB_1.pdf?v=1778137952\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e18 AWG 12C HELUKABEL 82985 JZ-602-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUL\/CSA approved, flexible control cable (up to 600 V) for machine, tool and plant construction. Suitable for medium mechanical stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Designed for export-oriented mechanical engineers, specifically in the USA and Canada. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e18 AWG 12C Shielded Control Cable CY PVC Control Cable Flexible EMC Control Cable Shielded Connection Cable Industrial Automation Cable PVC Flexible Control Cable Braided Shield Control Cable Tinned 18 AWG 12C Copper Shielded Cable UL\/CSA Approved Control Cable 600V Flexible Control Cable Oil-Resistant Control Cable Machine Tool Control Cable EMC Preferred Type Cable Flexible Signal \u0026amp; Control Cable Multi-Core Shielded Cable Grey Jacket 18 AWG 12C Control Cable Grounded Control Cable JZ-602-CY Ungrounded Control Cable Industrial Connection Cable Flexible Power and Control Cable\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable acc. to UL-Std. 758 (AWM) Style 2587, CSA-Std. C22.2 No. 210 - AWM I\/II A\/B\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -10°C to +90°C\u003cbr\u003efixed -40°C to +90°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eUL (AWM) AC 600 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e3000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e6000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 10x Outer-Ø\u003cbr\u003efixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to UL-Std. 758 (AWM) Style 11008, CSA-Std. C22.2 No. 210\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003e x = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2, UL VW-1, CSA FT1\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are\u003cbr\u003eapproximated, and are for reference only\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size :\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e18 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 12 G 1\u003cb\u003e\u003cbr\u003e• Outer-Ø min - max mm:\u003c\/b\u003e 13.3\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 184.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx: \u003c\/b\u003e341.0\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63574185083249,"sku":"NNC82985","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_73f2a470-8403-4839-8108-b3f08f57c71a.png?v=1778149617"},{"product_id":"18-awg-18c-helukabel-82986-jz-602-cy-pvc-control-and-connection-cable","title":"18 AWG 18C HELUKABEL 82986 JZ-602-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M82990_EN_GB_1.pdf?v=1778137952\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e18 AWG 18C HELUKABEL 82986 JZ-602-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUL\/CSA approved, flexible control cable (up to 600 V) for machine, tool and plant construction. Suitable for medium mechanical stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Designed for export-oriented mechanical engineers, specifically in the USA and Canada. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e18 AWG 18C Shielded Control Cable CY PVC Control Cable Flexible EMC Control Cable Shielded Connection Cable Industrial Automation Cable PVC Flexible Control Cable Braided Shield Control Cable Tinned 18 AWG 18C Copper Shielded Cable UL\/CSA Approved Control Cable 600V Flexible Control Cable Oil-Resistant Control Cable Machine Tool Control Cable EMC Preferred Type Cable Flexible Signal \u0026amp; Control Cable Multi-Core Shielded Cable Grey Jacket 18 AWG 18C Control Cable Grounded Control Cable JZ-602-CY Ungrounded Control Cable Industrial Connection Cable Flexible Power and Control Cable\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable acc. to UL-Std. 758 (AWM) Style 2587, CSA-Std. C22.2 No. 210 - AWM I\/II A\/B\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -10°C to +90°C\u003cbr\u003efixed -40°C to +90°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eUL (AWM) AC 600 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e3000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e6000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 10x Outer-Ø\u003cbr\u003efixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to UL-Std. 758 (AWM) Style 11008, CSA-Std. C22.2 No. 210\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003e x = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2, UL VW-1, CSA FT1\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are\u003cbr\u003eapproximated, and are for reference only\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size :\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e18 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 18 G 1\u003cb\u003e\u003cbr\u003e• Outer-Ø min - max mm:\u003c\/b\u003e 15.3\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 260.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx: \u003c\/b\u003e473.0\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63574189244785,"sku":"NNC82986","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_73f2a470-8403-4839-8108-b3f08f57c71a.png?v=1778149617"},{"product_id":"18-awg-25c-helukabel-82987-jz-602-cy-pvc-control-and-connection-cable","title":"18 AWG 25C HELUKABEL 82987 JZ-602-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M82990_EN_GB_1.pdf?v=1778137952\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e18 AWG 25C HELUKABEL 82987 JZ-602-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUL\/CSA approved, flexible control cable (up to 600 V) for machine, tool and plant construction. Suitable for medium mechanical stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Designed for export-oriented mechanical engineers, specifically in the USA and Canada. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e18 AWG 25C Shielded Control Cable CY PVC Control Cable Flexible EMC Control Cable Shielded Connection Cable Industrial Automation Cable PVC Flexible Control Cable Braided Shield Control Cable Tinned 18 AWG 25C Copper Shielded Cable UL\/CSA Approved Control Cable 600V Flexible Control Cable Oil-Resistant Control Cable Machine Tool Control Cable EMC Preferred Type Cable Flexible Signal \u0026amp; Control Cable Multi-Core Shielded Cable Grey Jacket 18 AWG 25C Control Cable Grounded Control Cable JZ-602-CY Ungrounded Control Cable Industrial Connection Cable Flexible Power and Control Cable\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable acc. to UL-Std. 758 (AWM) Style 2587, CSA-Std. C22.2 No. 210 - AWM I\/II A\/B\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -10°C to +90°C\u003cbr\u003efixed -40°C to +90°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eUL (AWM) AC 600 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e3000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e6000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 10x Outer-Ø\u003cbr\u003efixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to UL-Std. 758 (AWM) Style 11008, CSA-Std. C22.2 No. 210\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003e x = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2, UL VW-1, CSA FT1\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are\u003cbr\u003eapproximated, and are for reference only\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size :\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e18 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 25 G 1\u003cb\u003e\u003cbr\u003e• Outer-Ø min - max mm:\u003c\/b\u003e 18.0\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 349.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx: \u003c\/b\u003e650.0\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63574191374705,"sku":"NNC82987","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_73f2a470-8403-4839-8108-b3f08f57c71a.png?v=1778149617"},{"product_id":"18-awg-34c-helukabel-82988-jz-602-cy-pvc-control-and-connection-cable","title":"18 AWG 34C HELUKABEL 82988 JZ-602-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M82990_EN_GB_1.pdf?v=1778137952\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e18 AWG 34C HELUKABEL 82988 JZ-602-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUL\/CSA approved, flexible control cable (up to 600 V) for machine, tool and plant construction. Suitable for medium mechanical stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Designed for export-oriented mechanical engineers, specifically in the USA and Canada. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e18 AWG 34C Shielded Control Cable CY PVC Control Cable Flexible EMC Control Cable Shielded Connection Cable Industrial Automation Cable PVC Flexible Control Cable Braided Shield Control Cable Tinned 18 AWG 34C Copper Shielded Cable UL\/CSA Approved Control Cable 600V Flexible Control Cable Oil-Resistant Control Cable Machine Tool Control Cable EMC Preferred Type Cable Flexible Signal \u0026amp; Control Cable Multi-Core Shielded Cable Grey Jacket 18 AWG 34C Control Cable Grounded Control Cable JZ-602-CY Ungrounded Control Cable Industrial Connection Cable Flexible Power and Control Cable\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable acc. to UL-Std. 758 (AWM) Style 2587, CSA-Std. C22.2 No. 210 - AWM I\/II A\/B\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -10°C to +90°C\u003cbr\u003efixed -40°C to +90°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eUL (AWM) AC 600 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e3000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e6000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 10x Outer-Ø\u003cbr\u003efixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to UL-Std. 758 (AWM) Style 11008, CSA-Std. C22.2 No. 210\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003e x = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2, UL VW-1, CSA FT1\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are\u003cbr\u003eapproximated, and are for reference only\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size :\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e18 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 34 G 1\u003cb\u003e\u003cbr\u003e• Outer-Ø min - max mm:\u003c\/b\u003e 20.5\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 486.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx: \u003c\/b\u003e781.0\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63574192226673,"sku":"NNC82988","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_73f2a470-8403-4839-8108-b3f08f57c71a.png?v=1778149617"},{"product_id":"18-awg-41c-helukabel-82989-jz-602-cy-pvc-control-and-connection-cable","title":"18 AWG 41C HELUKABEL 82989 JZ-602-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M82990_EN_GB_1.pdf?v=1778137952\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e18 AWG 41C HELUKABEL 82989 JZ-602-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUL\/CSA approved, flexible control cable (up to 600 V) for machine, tool and plant construction. Suitable for medium mechanical stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Designed for export-oriented mechanical engineers, specifically in the USA and Canada. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-start=\"132\" data-end=\"162\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e18 AWG 41C Shielded Control Cable CY PVC Control Cable Flexible EMC Control Cable Shielded Connection Cable Industrial Automation Cable PVC Flexible Control Cable Braided Shield Control Cable Tinned 18 AWG 41C Copper Shielded Cable UL\/CSA Approved Control Cable 600V Flexible Control Cable Oil-Resistant Control Cable Machine Tool Control Cable EMC Preferred Type Cable Flexible Signal \u0026amp; Control Cable Multi-Core Shielded Cable Grey Jacket 18 AWG 41C Control Cable Grounded Control Cable JZ-602-CY Ungrounded Control Cable Industrial Connection Cable Flexible Power and Control Cable\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable acc. to UL-Std. 758 (AWM) Style 2587, CSA-Std. C22.2 No. 210 - AWM I\/II A\/B\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -10°C to +90°C\u003cbr\u003efixed -40°C to +90°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eUL (AWM) AC 600 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e3000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e6000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 10x Outer-Ø\u003cbr\u003efixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to UL-Std. 758 (AWM) Style 11008, CSA-Std. C22.2 No. 210\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003e x = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2, UL VW-1, CSA FT1\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are\u003cbr\u003eapproximated, and are for reference only\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size :\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e18 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 41 G 1\u003cb\u003e\u003cbr\u003e• Outer-Ø min - max mm:\u003c\/b\u003e 22.0\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 531.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 892.0\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63574196322673,"sku":"NNC82989","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_73f2a470-8403-4839-8108-b3f08f57c71a.png?v=1778149617"},{"product_id":"16-awg-2c-helukabel-82968-oz-602-cy-pvc-control-and-connection-cable","title":"16 AWG 2C HELUKABEL 82968 OZ-602-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M82990_EN_GB_1.pdf?v=1778137952\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e16 AWG 2C HELUKABEL 82968 OZ-602-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUL\/CSA approved, flexible control cable (up to 600 V) for machine, tool and plant construction. Suitable for medium mechanical stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Designed for export-oriented mechanical engineers, specifically in the USA and Canada. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-start=\"132\" data-end=\"162\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e16 AWG 2C Shielded Control Cable CY PVC Control Cable Flexible EMC Control Cable Shielded Connection Cable Industrial Automation Cable PVC Flexible Control Cable Braided Shield Control Cable Tinned 16 AWG 2C Copper Shielded Cable UL\/CSA Approved Control Cable 600V Flexible Control Cable Oil-Resistant Control Cable Machine Tool Control Cable EMC Preferred Type Cable Flexible Signal \u0026amp; Control Cable Multi-Core Shielded Cable Grey Jacket 16 AWG 2C Control Cable Grounded Control Cable OZ-602-CY Ungrounded Control Cable Industrial Connection Cable Flexible Power and Control Cable\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable acc. to UL-Std. 758 (AWM) Style 2587, CSA-Std. C22.2 No. 210 - AWM I\/II A\/B\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -10°C to +90°C\u003cbr\u003efixed -40°C to +90°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eUL (AWM) AC 600 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e3000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e6000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 10x Outer-Ø\u003cbr\u003efixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to UL-Std. 758 (AWM) Style 11008, CSA-Std. C22.2 No. 210\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003e x = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2, UL VW-1, CSA FT1\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are\u003cbr\u003eapproximated, and are for reference only\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size :\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e16 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 2 x 1.5\u003cb\u003e\u003cbr\u003e• Outer-Ø min - max mm:\u003c\/b\u003e 8.4\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 63.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 136.0\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63574322250097,"sku":"NNC82968","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design-Photoroom_eadbcf32-7a27-4198-be17-6dc632ffcf68.png?v=1778219698"},{"product_id":"16-awg-3c-helukabel-82969-jz-602-cy-pvc-control-and-connection-cable","title":"16 AWG 3C HELUKABEL 82969 JZ-602-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M82990_EN_GB_1.pdf?v=1778137952\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e16 AWG 3C HELUKABEL 82969 JZ-602-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUL\/CSA approved, flexible control cable (up to 600 V) for machine, tool and plant construction. Suitable for medium mechanical stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Designed for export-oriented mechanical engineers, specifically in the USA and Canada. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e16 AWG 3C Shielded Control Cable CY PVC Control Cable Flexible EMC Control Cable Shielded Connection Cable Industrial Automation Cable PVC Flexible Control Cable Braided Shield Control Cable Tinned 16 AWG 3C Copper Shielded Cable UL\/CSA Approved Control Cable 600V Flexible Control Cable Oil-Resistant Control Cable Machine Tool Control Cable EMC Preferred Type Cable Flexible Signal \u0026amp; Control Cable Multi-Core Shielded Cable Grey Jacket 16 AWG 3C Control Cable Grounded Control Cable JZ-602-CY Ungrounded Control Cable Industrial Connection Cable Flexible Power and Control Cable\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable acc. to UL-Std. 758 (AWM) Style 2587, CSA-Std. C22.2 No. 210 - AWM I\/II A\/B\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -10°C to +90°C\u003cbr\u003efixed -40°C to +90°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eUL (AWM) AC 600 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e3000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e6000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 10x Outer-Ø\u003cbr\u003efixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to UL-Std. 758 (AWM) Style 11008, CSA-Std. C22.2 No. 210\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003e x = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2, UL VW-1, CSA FT1\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are\u003cbr\u003eapproximated, and are for reference only\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size :\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e16 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 3 G 1.5\u003cb\u003e\u003cbr\u003e• Outer-Ø min - max mm:\u003c\/b\u003e 9.0\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 80.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 165.0\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63574349775217,"sku":"NNC82969","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_d9cd8fd0-4bfb-4092-87a7-5b51e784e195.png?v=1778219906"},{"product_id":"16-awg-4c-helukabel-82970-jz-602-cy-pvc-control-and-connection-cable","title":"16 AWG 4C HELUKABEL 82970 JZ-602-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M82990_EN_GB_1.pdf?v=1778137952\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e16 AWG 4C HELUKABEL 82970 JZ-602-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUL\/CSA approved, flexible control cable (up to 600 V) for machine, tool and plant construction. Suitable for medium mechanical stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Designed for export-oriented mechanical engineers, specifically in the USA and Canada. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e16 AWG 4C Shielded Control Cable CY PVC Control Cable Flexible EMC Control Cable Shielded Connection Cable Industrial Automation Cable PVC Flexible Control Cable Braided Shield Control Cable Tinned 16 AWG 4C Copper Shielded Cable UL\/CSA Approved Control Cable 600V Flexible Control Cable Oil-Resistant Control Cable Machine Tool Control Cable EMC Preferred Type Cable Flexible Signal \u0026amp; Control Cable Multi-Core Shielded Cable Grey Jacket 16 AWG 4C Control Cable Grounded Control Cable JZ-602-CY Ungrounded Control Cable Industrial Connection Cable Flexible Power and Control Cable\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable acc. to UL-Std. 758 (AWM) Style 2587, CSA-Std. C22.2 No. 210 - AWM I\/II A\/B\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -10°C to +90°C\u003cbr\u003efixed -40°C to +90°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eUL (AWM) AC 600 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e3000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e6000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 10x Outer-Ø\u003cbr\u003efixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to UL-Std. 758 (AWM) Style 11008, CSA-Std. C22.2 No. 210\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003e x = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2, UL VW-1, CSA FT1\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are\u003cbr\u003eapproximated, and are for reference only\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size :\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e16 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 4 G 1.5\u003cb\u003e\u003cbr\u003e• Outer-Ø min - max mm:\u003c\/b\u003e 9.6\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 97.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 192.0\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63574393651569,"sku":"NNC82970","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_d9cd8fd0-4bfb-4092-87a7-5b51e784e195.png?v=1778219906"},{"product_id":"16-awg-5c-helukabel-82971-jz-602-cy-pvc-control-and-connection-cable","title":"16 AWG 5C HELUKABEL 82971 JZ-602-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M82990_EN_GB_1.pdf?v=1778137952\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e16 AWG 5C HELUKABEL 82971 JZ-602-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUL\/CSA approved, flexible control cable (up to 600 V) for machine, tool and plant construction. Suitable for medium mechanical stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Designed for export-oriented mechanical engineers, specifically in the USA and Canada. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e16 AWG 5C Shielded Control Cable CY PVC Control Cable Flexible EMC Control Cable Shielded Connection Cable Industrial Automation Cable PVC Flexible Control Cable Braided Shield Control Cable Tinned 16 AWG 5C Copper Shielded Cable UL\/CSA Approved Control Cable 600V Flexible Control Cable Oil-Resistant Control Cable Machine Tool Control Cable EMC Preferred Type Cable Flexible Signal \u0026amp; Control Cable Multi-Core Shielded Cable Grey Jacket 16 AWG 5C Control Cable Grounded Control Cable JZ-602-CY Ungrounded Control Cable Industrial Connection Cable Flexible Power and Control Cable\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable acc. to UL-Std. 758 (AWM) Style 2587, CSA-Std. C22.2 No. 210 - AWM I\/II A\/B\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -10°C to +90°C\u003cbr\u003efixed -40°C to +90°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eUL (AWM) AC 600 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e3000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e6000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 10x Outer-Ø\u003cbr\u003efixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to UL-Std. 758 (AWM) Style 11008, CSA-Std. C22.2 No. 210\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003e x = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2, UL VW-1, CSA FT1\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are\u003cbr\u003eapproximated, and are for reference only\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size :\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e16 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 5 G 1.5\u003cb\u003e\u003cbr\u003e• Outer-Ø min - max mm:\u003c\/b\u003e 10.5\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 119.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 224.0\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63574405251441,"sku":"NNC82971","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_d9cd8fd0-4bfb-4092-87a7-5b51e784e195.png?v=1778219906"},{"product_id":"16-awg-7c-helukabel-82972-jz-602-cy-pvc-control-and-connection-cable","title":"16 AWG 7C HELUKABEL 82972 JZ-602-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M82990_EN_GB_1.pdf?v=1778137952\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e16 AWG 7C HELUKABEL 82972 JZ-602-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUL\/CSA approved, flexible control cable (up to 600 V) for machine, tool and plant construction. Suitable for medium mechanical stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Designed for export-oriented mechanical engineers, specifically in the USA and Canada. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e16 AWG 7C Shielded Control Cable CY PVC Control Cable Flexible EMC Control Cable Shielded Connection Cable Industrial Automation Cable PVC Flexible Control Cable Braided Shield Control Cable Tinned 16 AWG 7C Copper Shielded Cable UL\/CSA Approved Control Cable 600V Flexible Control Cable Oil-Resistant Control Cable Machine Tool Control Cable EMC Preferred Type Cable Flexible Signal \u0026amp; Control Cable Multi-Core Shielded Cable Grey Jacket 16 AWG 7C Control Cable Grounded Control Cable JZ-602-CY Ungrounded Control Cable Industrial Connection Cable Flexible Power and Control Cable\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable acc. to UL-Std. 758 (AWM) Style 2587, CSA-Std. C22.2 No. 210 - AWM I\/II A\/B\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -10°C to +90°C\u003cbr\u003efixed -40°C to +90°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eUL (AWM) AC 600 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e3000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e6000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 10x Outer-Ø\u003cbr\u003efixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to UL-Std. 758 (AWM) Style 11008, CSA-Std. C22.2 No. 210\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003e x = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2, UL VW-1, CSA FT1\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are\u003cbr\u003eapproximated, and are for reference only\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size :\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e16 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 7 G 1.5\u003cb\u003e\u003cbr\u003e• Outer-Ø min - max mm:\u003c\/b\u003e 11.2\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 147.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 273.0\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63574422847857,"sku":"NNC82972","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_d9cd8fd0-4bfb-4092-87a7-5b51e784e195.png?v=1778219906"},{"product_id":"16-awg-9c-helukabel-82973-jz-602-cy-pvc-control-and-connection-cable","title":"16 AWG 9C HELUKABEL 82973 JZ-602-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M82990_EN_GB_1.pdf?v=1778137952\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e16 AWG 9C HELUKABEL 82973 JZ-602-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUL\/CSA approved, flexible control cable (up to 600 V) for machine, tool and plant construction. Suitable for medium mechanical stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Designed for export-oriented mechanical engineers, specifically in the USA and Canada. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e16 AWG 9C Shielded Control Cable CY PVC Control Cable Flexible EMC Control Cable Shielded Connection Cable Industrial Automation Cable PVC Flexible Control Cable Braided Shield Control Cable Tinned 16 AWG 9C Copper Shielded Cable UL\/CSA Approved Control Cable 600V Flexible Control Cable Oil-Resistant Control Cable Machine Tool Control Cable EMC Preferred Type Cable Flexible Signal \u0026amp; Control Cable Multi-Core Shielded Cable Grey Jacket 16 AWG 9C Control Cable Grounded Control Cable JZ-602-CY Ungrounded Control Cable Industrial Connection Cable Flexible Power and Control Cable\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable acc. to UL-Std. 758 (AWM) Style 2587, CSA-Std. C22.2 No. 210 - AWM I\/II A\/B\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -10°C to +90°C\u003cbr\u003efixed -40°C to +90°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eUL (AWM) AC 600 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e3000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e6000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 10x Outer-Ø\u003cbr\u003efixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to UL-Std. 758 (AWM) Style 11008, CSA-Std. C22.2 No. 210\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003e x = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2, UL VW-1, CSA FT1\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are\u003cbr\u003eapproximated, and are for reference only\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size :\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e16 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 9 G 1.5\u003cb\u003e\u003cbr\u003e• Outer-Ø min - max mm:\u003c\/b\u003e 13.3\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 182.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 340.0\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63574436249969,"sku":"NNC82973","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_d9cd8fd0-4bfb-4092-87a7-5b51e784e195.png?v=1778219906"},{"product_id":"16-awg-12c-helukabel-82974-jz-602-cy-pvc-control-and-connection-cable","title":"16 AWG 12C HELUKABEL 82974 JZ-602-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M82990_EN_GB_1.pdf?v=1778137952\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e16 AWG 12C HELUKABEL 82974 JZ-602-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUL\/CSA approved, flexible control cable (up to 600 V) for machine, tool and plant construction. Suitable for medium mechanical stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Designed for export-oriented mechanical engineers, specifically in the USA and Canada. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e16 AWG 12C Shielded Control Cable CY PVC Control Cable Flexible EMC Control Cable Shielded Connection Cable Industrial Automation Cable PVC Flexible Control Cable Braided Shield Control Cable Tinned 16 AWG 12C Copper Shielded Cable UL\/CSA Approved Control Cable 600V Flexible Control Cable Oil-Resistant Control Cable Machine Tool Control Cable EMC Preferred Type Cable Flexible Signal \u0026amp; Control Cable Multi-Core Shielded Cable Grey Jacket 16 AWG 12C Control Cable Grounded Control Cable JZ-602-CY Ungrounded Control Cable Industrial Connection Cable Flexible Power and Control Cable\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable acc. to UL-Std. 758 (AWM) Style 2587, CSA-Std. C22.2 No. 210 - AWM I\/II A\/B\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -10°C to +90°C\u003cbr\u003efixed -40°C to +90°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eUL (AWM) AC 600 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e3000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e6000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 10x Outer-Ø\u003cbr\u003efixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to UL-Std. 758 (AWM) Style 11008, CSA-Std. C22.2 No. 210\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003e x = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2, UL VW-1, CSA FT1\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are\u003cbr\u003eapproximated, and are for reference only\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size :\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e16 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 12 G 1.5\u003cb\u003e\u003cbr\u003e• Outer-Ø min - max mm:\u003c\/b\u003e 14.7\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 267.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 461.0\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63574444409201,"sku":"NNC82974","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_d9cd8fd0-4bfb-4092-87a7-5b51e784e195.png?v=1778219906"},{"product_id":"16-awg-18c-helukabel-82975-jz-602-cy-pvc-control-and-connection-cable","title":"16 AWG 18C HELUKABEL 82975 JZ-602-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M82990_EN_GB_1.pdf?v=1778137952\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e16 AWG 18C HELUKABEL 82975 JZ-602-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUL\/CSA approved, flexible control cable (up to 600 V) for machine, tool and plant construction. Suitable for medium mechanical stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Designed for export-oriented mechanical engineers, specifically in the USA and Canada. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e16 AWG 18C Shielded Control Cable CY PVC Control Cable Flexible EMC Control Cable Shielded Connection Cable Industrial Automation Cable PVC Flexible Control Cable Braided Shield Control Cable Tinned 16 AWG 18C Copper Shielded Cable UL\/CSA Approved Control Cable 600V Flexible Control Cable Oil-Resistant Control Cable Machine Tool Control Cable EMC Preferred Type Cable Flexible Signal \u0026amp; Control Cable Multi-Core Shielded Cable Grey Jacket 16 AWG 18C Control Cable Grounded Control Cable JZ-602-CY Ungrounded Control Cable Industrial Connection Cable Flexible Power and Control Cable\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable acc. to UL-Std. 758 (AWM) Style 2587, CSA-Std. C22.2 No. 210 - AWM I\/II A\/B\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -10°C to +90°C\u003cbr\u003efixed -40°C to +90°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eUL (AWM) AC 600 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e3000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e6000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 10x Outer-Ø\u003cbr\u003efixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to UL-Std. 758 (AWM) Style 11008, CSA-Std. C22.2 No. 210\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003e x = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2, UL VW-1, CSA FT1\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are\u003cbr\u003eapproximated, and are for reference only\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size :\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e16 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 18 G 1.5\u003cb\u003e\u003cbr\u003e• Outer-Ø min - max mm:\u003c\/b\u003e 17.0\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 374.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 674.0\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63574453387633,"sku":"NNC82975","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_d9cd8fd0-4bfb-4092-87a7-5b51e784e195.png?v=1778219906"},{"product_id":"16-awg-25c-helukabel-82976-jz-602-cy-pvc-control-and-connection-cable","title":"16 AWG 25C HELUKABEL 82976 JZ-602-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M82990_EN_GB_1.pdf?v=1778137952\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e16 AWG 25C HELUKABEL 82976 JZ-602-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUL\/CSA approved, flexible control cable (up to 600 V) for machine, tool and plant construction. Suitable for medium mechanical stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Designed for export-oriented mechanical engineers, specifically in the USA and Canada. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e16 AWG 25C Shielded Control Cable CY PVC Control Cable Flexible EMC Control Cable Shielded Connection Cable Industrial Automation Cable PVC Flexible Control Cable Braided Shield Control Cable Tinned 16 AWG 25C Copper Shielded Cable UL\/CSA Approved Control Cable 600V Flexible Control Cable Oil-Resistant Control Cable Machine Tool Control Cable EMC Preferred Type Cable Flexible Signal \u0026amp; Control Cable Multi-Core Shielded Cable Grey Jacket 16 AWG 25C Control Cable Grounded Control Cable JZ-602-CY Ungrounded Control Cable Industrial Connection Cable Flexible Power and Control Cable\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable acc. to UL-Std. 758 (AWM) Style 2587, CSA-Std. C22.2 No. 210 - AWM I\/II A\/B\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -10°C to +90°C\u003cbr\u003efixed -40°C to +90°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eUL (AWM) AC 600 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e3000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e6000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 10x Outer-Ø\u003cbr\u003efixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to UL-Std. 758 (AWM) Style 11008, CSA-Std. C22.2 No. 210\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003e x = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2, UL VW-1, CSA FT1\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are\u003cbr\u003eapproximated, and are for reference only\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size :\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e16 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 25 G 1.5\u003cb\u003e\u003cbr\u003e• Outer-Ø min - max mm:\u003c\/b\u003e 20.2\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 526.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 950.0\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63574463381873,"sku":"NNC82976","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_d9cd8fd0-4bfb-4092-87a7-5b51e784e195.png?v=1778219906"},{"product_id":"16-awg-34c-helukabel-82977-jz-602-cy-pvc-control-and-connection-cable","title":"16 AWG 34C HELUKABEL 82977 JZ-602-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M82990_EN_GB_1.pdf?v=1778137952\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e16 AWG 34C HELUKABEL 82977 JZ-602-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUL\/CSA approved, flexible control cable (up to 600 V) for machine, tool and plant construction. Suitable for medium mechanical stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Designed for export-oriented mechanical engineers, specifically in the USA and Canada. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e16 AWG 34C Shielded Control Cable CY PVC Control Cable Flexible EMC Control Cable Shielded Connection Cable Industrial Automation Cable PVC Flexible Control Cable Braided Shield Control Cable Tinned 16 AWG 34C Copper Shielded Cable UL\/CSA Approved Control Cable 600V Flexible Control Cable Oil-Resistant Control Cable Machine Tool Control Cable EMC Preferred Type Cable Flexible Signal \u0026amp; Control Cable Multi-Core Shielded Cable Grey Jacket 16 AWG 34C Control Cable Grounded Control Cable JZ-602-CY Ungrounded Control Cable Industrial Connection Cable Flexible Power and Control Cable\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable acc. to UL-Std. 758 (AWM) Style 2587, CSA-Std. C22.2 No. 210 - AWM I\/II A\/B\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -10°C to +90°C\u003cbr\u003efixed -40°C to +90°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eUL (AWM) AC 600 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e3000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e6000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 10x Outer-Ø\u003cbr\u003efixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to UL-Std. 758 (AWM) Style 11008, CSA-Std. C22.2 No. 210\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003e x = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2, UL VW-1, CSA FT1\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are\u003cbr\u003eapproximated, and are for reference only\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size :\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e16 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 34 G 1.5\u003cb\u003e\u003cbr\u003e• Outer-Ø min - max mm:\u003c\/b\u003e 23.0\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 629.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 1203.0\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63574492578161,"sku":"NNC82977","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_d9cd8fd0-4bfb-4092-87a7-5b51e784e195.png?v=1778219906"},{"product_id":"16-awg-41c-helukabel-82978-jz-602-cy-pvc-control-and-connection-cable","title":"16 AWG 41C HELUKABEL 82978 JZ-602-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M82990_EN_GB_1.pdf?v=1778137952\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e16 AWG 41C HELUKABEL 82978 JZ-602-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUL\/CSA approved, flexible control cable (up to 600 V) for machine, tool and plant construction. Suitable for medium mechanical stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Designed for export-oriented mechanical engineers, specifically in the USA and Canada. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e16 AWG 41C Shielded Control Cable CY PVC Control Cable Flexible EMC Control Cable Shielded Connection Cable Industrial Automation Cable PVC Flexible Control Cable Braided Shield Control Cable Tinned 16 AWG 41C Copper Shielded Cable UL\/CSA Approved Control Cable 600V Flexible Control Cable Oil-Resistant Control Cable Machine Tool Control Cable EMC Preferred Type Cable Flexible Signal \u0026amp; Control Cable Multi-Core Shielded Cable Grey Jacket 16 AWG 41C Control Cable Grounded Control Cable JZ-602-CY Ungrounded Control Cable Industrial Connection Cable Flexible Power and Control Cable\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable acc. to UL-Std. 758 (AWM) Style 2587, CSA-Std. C22.2 No. 210 - AWM I\/II A\/B\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -10°C to +90°C\u003cbr\u003efixed -40°C to +90°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eUL (AWM) AC 600 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e3000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e6000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 10x Outer-Ø\u003cbr\u003efixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to UL-Std. 758 (AWM) Style 11008, CSA-Std. C22.2 No. 210\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003e x = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2, UL VW-1, CSA FT1\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are\u003cbr\u003eapproximated, and are for reference only\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size :\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e16 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 41 G 1.5\u003cb\u003e\u003cbr\u003e• Outer-Ø min - max mm:\u003c\/b\u003e 25.1\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 801.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 1588.0\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63574506307953,"sku":"NNC82978","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_d9cd8fd0-4bfb-4092-87a7-5b51e784e195.png?v=1778219906"},{"product_id":"14-awg-2c-helukabel-82959-oz-602-cy-pvc-control-and-connection-cable","title":"14 AWG 2C HELUKABEL 82959 OZ-602-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M82990_EN_GB_1.pdf?v=1778137952\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 2C HELUKABEL 82959 OZ-602-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUL\/CSA approved, flexible control cable (up to 600 V) for machine, tool and plant construction. Suitable for medium mechanical stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Designed for export-oriented mechanical engineers, specifically in the USA and Canada. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e14 AWG 2C Shielded Control Cable CY PVC Control Cable Flexible EMC Control Cable Shielded Connection Cable Industrial Automation Cable PVC Flexible Control Cable Braided Shield Control Cable Tinned 14 AWG 2C Copper Shielded Cable UL\/CSA Approved Control Cable 600V Flexible Control Cable Oil-Resistant Control Cable Machine Tool Control Cable EMC Preferred Type Cable Flexible Signal \u0026amp; Control Cable Multi-Core Shielded Cable Grey Jacket 14 AWG 2C Control Cable Grounded Control Cable OZ-602-CY Ungrounded Control Cable Industrial Connection Cable Flexible Power and Control Cable\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable acc. to UL-Std. 758 (AWM) Style 2587, CSA-Std. C22.2 No. 210 - AWM I\/II A\/B\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -10°C to +90°C\u003cbr\u003efixed -40°C to +90°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eUL (AWM) AC 600 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e3000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e6000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 10x Outer-Ø\u003cbr\u003efixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to UL-Std. 758 (AWM) Style 11008, CSA-Std. C22.2 No. 210\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003e x = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2, UL VW-1, CSA FT1\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are\u003cbr\u003eapproximated, and are for reference only\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size :\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e14 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 2 x 2.5\u003cb\u003e\u003cbr\u003e• Outer-Ø min - max mm:\u003c\/b\u003e 9.8\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 96.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 173.0\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63574569812337,"sku":"NNC82959","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design-Photoroom_ccb672b8-cb07-4f55-aa42-29730b1643f7.png?v=1778235234"},{"product_id":"14-awg-3c-helukabel-82960-jz-602-cy-pvc-control-and-connection-cable","title":"14 AWG 3C HELUKABEL 82960 JZ-602-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M82990_EN_GB_1.pdf?v=1778137952\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 3C HELUKABEL 82960 JZ-602-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUL\/CSA approved, flexible control cable (up to 600 V) for machine, tool and plant construction. Suitable for medium mechanical stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Designed for export-oriented mechanical engineers, specifically in the USA and Canada. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e14 AWG 3C Shielded Control Cable CY PVC Control Cable Flexible EMC Control Cable Shielded Connection Cable Industrial Automation Cable PVC Flexible Control Cable Braided Shield Control Cable Tinned 14 AWG 3C Copper Shielded Cable UL\/CSA Approved Control Cable 600V Flexible Control Cable Oil-Resistant Control Cable Machine Tool Control Cable EMC Preferred Type Cable Flexible Signal \u0026amp; Control Cable Multi-Core Shielded Cable Grey Jacket 14 AWG 3C Control Cable Grounded Control Cable JZ-602-CY Ungrounded Control Cable Industrial Connection Cable Flexible Power and Control Cable\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable acc. to UL-Std. 758 (AWM) Style 2587, CSA-Std. C22.2 No. 210 - AWM I\/II A\/B\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -10°C to +90°C\u003cbr\u003efixed -40°C to +90°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eUL (AWM) AC 600 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e3000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e6000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 10x Outer-Ø\u003cbr\u003efixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to UL-Std. 758 (AWM) Style 11008, CSA-Std. C22.2 No. 210\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003e x = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2, UL VW-1, CSA FT1\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are\u003cbr\u003eapproximated, and are for reference only\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size :\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e14 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 3 G 2.5\u003cb\u003e\u003cbr\u003e• Outer-Ø min - max mm:\u003c\/b\u003e 10.5\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 144.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 220.0\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63574576562545,"sku":"NNC82960","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_d9cd8fd0-4bfb-4092-87a7-5b51e784e195.png?v=1778219906"},{"product_id":"14-awg-4c-helukabel-82961-jz-602-cy-pvc-control-and-connection-cable","title":"14 AWG 4C HELUKABEL 82961 JZ-602-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M82990_EN_GB_1.pdf?v=1778137952\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 4C HELUKABEL 82961 JZ-602-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUL\/CSA approved, flexible control cable (up to 600 V) for machine, tool and plant construction. Suitable for medium mechanical stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Designed for export-oriented mechanical engineers, specifically in the USA and Canada. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e14 AWG 4C Shielded Control Cable CY PVC Control Cable Flexible EMC Control Cable Shielded Connection Cable Industrial Automation Cable PVC Flexible Control Cable Braided Shield Control Cable Tinned 14 AWG 4C Copper Shielded Cable UL\/CSA Approved Control Cable 600V Flexible Control Cable Oil-Resistant Control Cable Machine Tool Control Cable EMC Preferred Type Cable Flexible Signal \u0026amp; Control Cable Multi-Core Shielded Cable Grey Jacket 14 AWG 4C Control Cable Grounded Control Cable JZ-602-CY Ungrounded Control Cable Industrial Connection Cable Flexible Power and Control Cable\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable acc. to UL-Std. 758 (AWM) Style 2587, CSA-Std. C22.2 No. 210 - AWM I\/II A\/B\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -10°C to +90°C\u003cbr\u003efixed -40°C to +90°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eUL (AWM) AC 600 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e3000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e6000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 10x Outer-Ø\u003cbr\u003efixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to UL-Std. 758 (AWM) Style 11008, CSA-Std. C22.2 No. 210\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003e x = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2, UL VW-1, CSA FT1\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are\u003cbr\u003eapproximated, and are for reference only\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size :\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e14 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 4 G 2.5\u003cb\u003e\u003cbr\u003e• Outer-Ø min - max mm:\u003c\/b\u003e 11.2\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 148.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 270.0\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63574584820081,"sku":"NNC82961","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_d9cd8fd0-4bfb-4092-87a7-5b51e784e195.png?v=1778219906"},{"product_id":"14-awg-5c-helukabel-82962-jz-602-cy-pvc-control-and-connection-cable","title":"14 AWG 5C HELUKABEL 82962 JZ-602-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M82990_EN_GB_1.pdf?v=1778137952\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 5C HELUKABEL 82962 JZ-602-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUL\/CSA approved, flexible control cable (up to 600 V) for machine, tool and plant construction. Suitable for medium mechanical stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Designed for export-oriented mechanical engineers, specifically in the USA and Canada. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-start=\"132\" data-end=\"162\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e14 AWG 5C Shielded Control Cable CY PVC Control Cable Flexible EMC Control Cable Shielded Connection Cable Industrial Automation Cable PVC Flexible Control Cable Braided Shield Control Cable Tinned 14 AWG 5C Copper Shielded Cable UL\/CSA Approved Control Cable 600V Flexible Control Cable Oil-Resistant Control Cable Machine Tool Control Cable EMC Preferred Type Cable Flexible Signal \u0026amp; Control Cable Multi-Core Shielded Cable Grey Jacket 14 AWG 5C Control Cable Grounded Control Cable JZ-602-CY Ungrounded Control Cable Industrial Connection Cable Flexible Power and Control Cable\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable acc. to UL-Std. 758 (AWM) Style 2587, CSA-Std. C22.2 No. 210 - AWM I\/II A\/B\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -10°C to +90°C\u003cbr\u003efixed -40°C to +90°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eUL (AWM) AC 600 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e3000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e6000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 10x Outer-Ø\u003cbr\u003efixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to UL-Std. 758 (AWM) Style 11008, CSA-Std. C22.2 No. 210\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003e x = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2, UL VW-1, CSA FT1\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are\u003cbr\u003eapproximated, and are for reference only\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size :\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e14 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 5 G 2.5\u003cb\u003e\u003cbr\u003e• Outer-Ø min - max mm:\u003c\/b\u003e 12.5\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 181.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 329.0\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63574593831281,"sku":"NNC82962","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_d9cd8fd0-4bfb-4092-87a7-5b51e784e195.png?v=1778219906"},{"product_id":"14-awg-7c-helukabel-82963-jz-602-cy-pvc-control-and-connection-cable","title":"14 AWG 7C HELUKABEL 82963 JZ-602-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M82990_EN_GB_1.pdf?v=1778137952\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 7C HELUKABEL 82963 JZ-602-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUL\/CSA approved, flexible control cable (up to 600 V) for machine, tool and plant construction. Suitable for medium mechanical stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Designed for export-oriented mechanical engineers, specifically in the USA and Canada. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-start=\"132\" data-end=\"162\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e14 AWG 7C Shielded Control Cable CY PVC Control Cable Flexible EMC Control Cable Shielded Connection Cable Industrial Automation Cable PVC Flexible Control Cable Braided Shield Control Cable Tinned 14 AWG 7C Copper Shielded Cable UL\/CSA Approved Control Cable 600V Flexible Control Cable Oil-Resistant Control Cable Machine Tool Control Cable EMC Preferred Type Cable Flexible Signal \u0026amp; Control Cable Multi-Core Shielded Cable Grey Jacket 14 AWG 7C Control Cable Grounded Control Cable JZ-602-CY Ungrounded Control Cable Industrial Connection Cable Flexible Power and Control Cable\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable acc. to UL-Std. 758 (AWM) Style 2587, CSA-Std. C22.2 No. 210 - AWM I\/II A\/B\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -10°C to +90°C\u003cbr\u003efixed -40°C to +90°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eUL (AWM) AC 600 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e3000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e6000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 10x Outer-Ø\u003cbr\u003efixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to UL-Std. 758 (AWM) Style 11008, CSA-Std. C22.2 No. 210\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003e x = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2, UL VW-1, CSA FT1\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are\u003cbr\u003eapproximated, and are for reference only\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size :\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e14 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 7 G 2.5\u003cb\u003e\u003cbr\u003e• Outer-Ø min - max mm:\u003c\/b\u003e 13.6\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 255.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 428.0\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63574602187121,"sku":"NNC82963","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_d9cd8fd0-4bfb-4092-87a7-5b51e784e195.png?v=1778219906"},{"product_id":"14-awg-9c-helukabel-82964-jz-602-cy-pvc-control-and-connection-cable","title":"14 AWG 9C HELUKABEL 82964 JZ-602-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M82990_EN_GB_1.pdf?v=1778137952\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 9C HELUKABEL 82964 JZ-602-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUL\/CSA approved, flexible control cable (up to 600 V) for machine, tool and plant construction. Suitable for medium mechanical stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Designed for export-oriented mechanical engineers, specifically in the USA and Canada. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-start=\"132\" data-end=\"162\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e14 AWG 9C Shielded Control Cable CY PVC Control Cable Flexible EMC Control Cable Shielded Connection Cable Industrial Automation Cable PVC Flexible Control Cable Braided Shield Control Cable Tinned 14 AWG 9C Copper Shielded Cable UL\/CSA Approved Control Cable 600V Flexible Control Cable Oil-Resistant Control Cable Machine Tool Control Cable EMC Preferred Type Cable Flexible Signal \u0026amp; Control Cable Multi-Core Shielded Cable Grey Jacket 14 AWG 9C Control Cable Grounded Control Cable JZ-602-CY Ungrounded Control Cable Industrial Connection Cable Flexible Power and Control Cable\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable acc. to UL-Std. 758 (AWM) Style 2587, CSA-Std. C22.2 No. 210 - AWM I\/II A\/B\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -10°C to +90°C\u003cbr\u003efixed -40°C to +90°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eUL (AWM) AC 600 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e3000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e6000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 10x Outer-Ø\u003cbr\u003efixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to UL-Std. 758 (AWM) Style 11008, CSA-Std. C22.2 No. 210\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003e x = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2, UL VW-1, CSA FT1\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are\u003cbr\u003eapproximated, and are for reference only\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size :\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e14 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 9 G 2.5\u003cb\u003e\u003cbr\u003e• Outer-Ø min - max mm:\u003c\/b\u003e 15.9\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 309.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 580.0\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63574608281969,"sku":"NNC82964","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_d9cd8fd0-4bfb-4092-87a7-5b51e784e195.png?v=1778219906"},{"product_id":"14-awg-12c-helukabel-82965-jz-602-cy-pvc-control-and-connection-cable","title":"14 AWG 12C HELUKABEL 82965 JZ-602-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M82990_EN_GB_1.pdf?v=1778137952\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 12C HELUKABEL 82965 JZ-602-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUL\/CSA approved, flexible control cable (up to 600 V) for machine, tool and plant construction. Suitable for medium mechanical stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Designed for export-oriented mechanical engineers, specifically in the USA and Canada. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-start=\"132\" data-end=\"162\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e14 AWG 12C Shielded Control Cable CY PVC Control Cable Flexible EMC Control Cable Shielded Connection Cable Industrial Automation Cable PVC Flexible Control Cable Braided Shield Control Cable Tinned 14 AWG 12C Copper Shielded Cable UL\/CSA Approved Control Cable 600V Flexible Control Cable Oil-Resistant Control Cable Machine Tool Control Cable EMC Preferred Type Cable Flexible Signal \u0026amp; Control Cable Multi-Core Shielded Cable Grey Jacket 14 AWG 12C Control Cable Grounded Control Cable JZ-602-CY Ungrounded Control Cable Industrial Connection Cable Flexible Power and Control Cable\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable acc. to UL-Std. 758 (AWM) Style 2587, CSA-Std. C22.2 No. 210 - AWM I\/II A\/B\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -10°C to +90°C\u003cbr\u003efixed -40°C to +90°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eUL (AWM) AC 600 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e3000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e6000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 10x Outer-Ø\u003cbr\u003efixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to UL-Std. 758 (AWM) Style 11008, CSA-Std. C22.2 No. 210\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003e x = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2, UL VW-1, CSA FT1\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are\u003cbr\u003eapproximated, and are for reference only\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size :\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e14 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 12 G 2.5\u003cb\u003e\u003cbr\u003e• Outer-Ø min - max mm:\u003c\/b\u003e 17.5\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 441.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 761.0\u003cbr\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63574616375665,"sku":"NNC82965","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_d9cd8fd0-4bfb-4092-87a7-5b51e784e195.png?v=1778219906"},{"product_id":"14-awg-18c-helukabel-82966-jz-602-cy-pvc-control-and-connection-cable","title":"14 AWG 18C HELUKABEL 82966 JZ-602-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M82990_EN_GB_1.pdf?v=1778137952\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 18C HELUKABEL 82966 JZ-602-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUL\/CSA approved, flexible control cable (up to 600 V) for machine, tool and plant construction. Suitable for medium mechanical stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Designed for export-oriented mechanical engineers, specifically in the USA and Canada. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-start=\"132\" data-end=\"162\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e14 AWG 18C Shielded Control Cable CY PVC Control Cable Flexible EMC Control Cable Shielded Connection Cable Industrial Automation Cable PVC Flexible Control Cable Braided Shield Control Cable Tinned 14 AWG 18C Copper Shielded Cable UL\/CSA Approved Control Cable 600V Flexible Control Cable Oil-Resistant Control Cable Machine Tool Control Cable EMC Preferred Type Cable Flexible Signal \u0026amp; Control Cable Multi-Core Shielded Cable Grey Jacket 14 AWG 18C Control Cable Grounded Control Cable JZ-602-CY Ungrounded Control Cable Industrial Connection Cable Flexible Power and Control Cable\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable acc. to UL-Std. 758 (AWM) Style 2587, CSA-Std. C22.2 No. 210 - AWM I\/II A\/B\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -10°C to +90°C\u003cbr\u003efixed -40°C to +90°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eUL (AWM) AC 600 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e3000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e6000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 10x Outer-Ø\u003cbr\u003efixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to UL-Std. 758 (AWM) Style 11008, CSA-Std. C22.2 No. 210\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003e x = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2, UL VW-1, CSA FT1\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are\u003cbr\u003eapproximated, and are for reference only\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size :\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e14 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 18 G 2.5\u003cb\u003e\u003cbr\u003e• Outer-Ø min - max mm:\u003c\/b\u003e 21.0\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 570.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 1140.0\u003cbr\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63574718251377,"sku":"NNC82966","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_d9cd8fd0-4bfb-4092-87a7-5b51e784e195.png?v=1778219906"},{"product_id":"14-awg-25c-helukabel-82967-jz-602-cy-pvc-control-and-connection-cable","title":"14 AWG 25C HELUKABEL 82967 JZ-602-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M82990_EN_GB_1.pdf?v=1778137952\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 25C HELUKABEL 82967 JZ-602-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUL\/CSA approved, flexible control cable (up to 600 V) for machine, tool and plant construction. Suitable for medium mechanical stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Designed for export-oriented mechanical engineers, specifically in the USA and Canada. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e14 AWG 25C Shielded Control Cable CY PVC Control Cable Flexible EMC Control Cable Shielded Connection Cable Industrial Automation Cable PVC Flexible Control Cable Braided Shield Control Cable Tinned 14 AWG 25C Copper Shielded Cable UL\/CSA Approved Control Cable 600V Flexible Control Cable Oil-Resistant Control Cable Machine Tool Control Cable EMC Preferred Type Cable Flexible Signal \u0026amp; Control Cable Multi-Core Shielded Cable Grey Jacket 14 AWG 25C Control Cable Grounded Control Cable JZ-602-CY Ungrounded Control Cable Industrial Connection Cable Flexible Power and Control Cable\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable acc. to UL-Std. 758 (AWM) Style 2587, CSA-Std. C22.2 No. 210 - AWM I\/II A\/B\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -10°C to +90°C\u003cbr\u003efixed -40°C to +90°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eUL (AWM) AC 600 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e3000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e6000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 10x Outer-Ø\u003cbr\u003efixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to UL-Std. 758 (AWM) Style 11008, CSA-Std. C22.2 No. 210\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003e x = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2, UL VW-1, CSA FT1\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are\u003cbr\u003eapproximated, and are for reference only\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size :\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e14 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 25 G 2.5\u003cb\u003e\u003cbr\u003e• Outer-Ø min - max mm:\u003c\/b\u003e 24.6\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 738.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 1551.0\u003cbr\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63574806233457,"sku":"NNC82967","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_d9cd8fd0-4bfb-4092-87a7-5b51e784e195.png?v=1778219906"},{"product_id":"12-awg-2c-helukabel-82954-oz-602-cy-pvc-control-and-connection-cable","title":"12 AWG 2C HELUKABEL 82954 OZ-602-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M82990_EN_GB_1.pdf?v=1778137952\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 2C HELUKABEL 82954 OZ-602-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUL\/CSA approved, flexible control cable (up to 600 V) for machine, tool and plant construction. Suitable for medium mechanical stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Designed for export-oriented mechanical engineers, specifically in the USA and Canada. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e12 AWG 2C Shielded Control Cable CY PVC Control Cable Flexible EMC Control Cable Shielded Connection Cable Industrial Automation Cable PVC Flexible Control Cable Braided Shield Control Cable Tinned 12 AWG 2C Copper Shielded Cable UL\/CSA Approved Control Cable 600V Flexible Control Cable Oil-Resistant Control Cable Machine Tool Control Cable EMC Preferred Type Cable Flexible Signal \u0026amp; Control Cable Multi-Core Shielded Cable Grey Jacket 12 AWG 2C Control Cable Grounded Control Cable OZ-602-CY Ungrounded Control Cable Industrial Connection Cable Flexible Power and Control Cable\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable acc. to UL-Std. 758 (AWM) Style 2587, CSA-Std. C22.2 No. 210 - AWM I\/II A\/B\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -10°C to +90°C\u003cbr\u003efixed -40°C to +90°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eUL (AWM) AC 600 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e3000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e6000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 10x Outer-Ø\u003cbr\u003efixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to UL-Std. 758 (AWM) Style 11008, CSA-Std. C22.2 No. 210\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003e x = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2, UL VW-1, CSA FT1\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are\u003cbr\u003eapproximated, and are for reference only\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size :\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e12 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 2 x 4\u003cb\u003e\u003cbr\u003e• Outer-Ø min - max mm:\u003c\/b\u003e 11.2\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 120.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 209.0\u003cbr\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63574917742961,"sku":"NNC82954","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design-Photoroom_ccb672b8-cb07-4f55-aa42-29730b1643f7.png?v=1778235234"},{"product_id":"12-awg-3c-helukabel-82955-jz-602-cy-pvc-control-and-connection-cable","title":"12 AWG 3C HELUKABEL 82955 JZ-602-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M82990_EN_GB_1.pdf?v=1778137952\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 3C HELUKABEL 82955 JZ-602-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUL\/CSA approved, flexible control cable (up to 600 V) for machine, tool and plant construction. Suitable for medium mechanical stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Designed for export-oriented mechanical engineers, specifically in the USA and Canada. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e12 AWG 3C Shielded Control Cable CY PVC Control Cable Flexible EMC Control Cable Shielded Connection Cable Industrial Automation Cable PVC Flexible Control Cable Braided Shield Control Cable Tinned 12 AWG 3C Copper Shielded Cable UL\/CSA Approved Control Cable 600V Flexible Control Cable Oil-Resistant Control Cable Machine Tool Control Cable EMC Preferred Type Cable Flexible Signal \u0026amp; Control Cable Multi-Core Shielded Cable Grey Jacket 12 AWG 3C Control Cable Grounded Control Cable JZ-602-CY Ungrounded Control Cable Industrial Connection Cable Flexible Power and Control Cable\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable acc. to UL-Std. 758 (AWM) Style 2587, CSA-Std. C22.2 No. 210 - AWM I\/II A\/B\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -10°C to +90°C\u003cbr\u003efixed -40°C to +90°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eUL (AWM) AC 600 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e3000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e6000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 10x Outer-Ø\u003cbr\u003efixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to UL-Std. 758 (AWM) Style 11008, CSA-Std. C22.2 No. 210\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003e x = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2, UL VW-1, CSA FT1\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are\u003cbr\u003eapproximated, and are for reference only\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size :\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e12 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 3 G 4\u003cb\u003e\u003cbr\u003e• Outer-Ø min - max mm:\u003c\/b\u003e 12.0\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 174.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 310.0\u003cbr\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63574942548337,"sku":"NNC82955","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_f926c033-48fb-4ba6-bf43-18a3ad56bdb8.png?v=1778233359"},{"product_id":"12-awg-4c-helukabel-82956-jz-602-cy-pvc-control-and-connection-cable","title":"12 AWG 4C HELUKABEL 82956 JZ-602-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M82990_EN_GB_1.pdf?v=1778137952\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 4C HELUKABEL 82956 JZ-602-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUL\/CSA approved, flexible control cable (up to 600 V) for machine, tool and plant construction. Suitable for medium mechanical stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Designed for export-oriented mechanical engineers, specifically in the USA and Canada. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e12 AWG 4C Shielded Control Cable CY PVC Control Cable Flexible EMC Control Cable Shielded Connection Cable Industrial Automation Cable PVC Flexible Control Cable Braided Shield Control Cable Tinned 12 AWG 4C Copper Shielded Cable UL\/CSA Approved Control Cable 600V Flexible Control Cable Oil-Resistant Control Cable Machine Tool Control Cable EMC Preferred Type Cable Flexible Signal \u0026amp; Control Cable Multi-Core Shielded Cable Grey Jacket 12 AWG 4C Control Cable Grounded Control Cable JZ-602-CY Ungrounded Control Cable Industrial Connection Cable Flexible Power and Control Cable\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable acc. to UL-Std. 758 (AWM) Style 2587, CSA-Std. C22.2 No. 210 - AWM I\/II A\/B\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -10°C to +90°C\u003cbr\u003efixed -40°C to +90°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eUL (AWM) AC 600 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e3000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e6000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 10x Outer-Ø\u003cbr\u003efixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to UL-Std. 758 (AWM) Style 11008, CSA-Std. C22.2 No. 210\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003e x = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2, UL VW-1, CSA FT1\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are\u003cbr\u003eapproximated, and are for reference only\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size :\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e12 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 4 G 4\u003cb\u003e\u003cbr\u003e• Outer-Ø min - max mm:\u003c\/b\u003e 13.3\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 230.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 456.0\u003cbr\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63574956573041,"sku":"NNC82956","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_f926c033-48fb-4ba6-bf43-18a3ad56bdb8.png?v=1778233359"},{"product_id":"12-awg-5c-helukabel-82957-jz-602-cy-pvc-control-and-connection-cable","title":"12 AWG 5C HELUKABEL 82957 JZ-602-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M82990_EN_GB_1.pdf?v=1778137952\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 5C HELUKABEL 82957 JZ-602-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUL\/CSA approved, flexible control cable (up to 600 V) for machine, tool and plant construction. Suitable for medium mechanical stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Designed for export-oriented mechanical engineers, specifically in the USA and Canada. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e12 AWG 5C Shielded Control Cable CY PVC Control Cable Flexible EMC Control Cable Shielded Connection Cable Industrial Automation Cable PVC Flexible Control Cable Braided Shield Control Cable Tinned 12 AWG 5C Copper Shielded Cable UL\/CSA Approved Control Cable 600V Flexible Control Cable Oil-Resistant Control Cable Machine Tool Control Cable EMC Preferred Type Cable Flexible Signal \u0026amp; Control Cable Multi-Core Shielded Cable Grey Jacket 12 AWG 5C Control Cable Grounded Control Cable JZ-602-CY Ungrounded Control Cable Industrial Connection Cable Flexible Power and Control Cable\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable acc. to UL-Std. 758 (AWM) Style 2587, CSA-Std. C22.2 No. 210 - AWM I\/II A\/B\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -10°C to +90°C\u003cbr\u003efixed -40°C to +90°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eUL (AWM) AC 600 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e3000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e6000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 10x Outer-Ø\u003cbr\u003efixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to UL-Std. 758 (AWM) Style 11008, CSA-Std. C22.2 No. 210\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003e x = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2, UL VW-1, CSA FT1\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are\u003cbr\u003eapproximated, and are for reference only\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size :\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e12 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 5 G 4\u003cb\u003e\u003cbr\u003e• Outer-Ø min - max mm:\u003c\/b\u003e 14.6\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 273.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 532.0\u003cbr\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63574964666737,"sku":"NNC82957","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_f926c033-48fb-4ba6-bf43-18a3ad56bdb8.png?v=1778233359"},{"product_id":"12-awg-7c-helukabel-82958-jz-602-cy-pvc-control-and-connection-cable","title":"12 AWG 7C HELUKABEL 82958 JZ-602-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M82990_EN_GB_1.pdf?v=1778137952\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 7C HELUKABEL 82958 JZ-602-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUL\/CSA approved, flexible control cable (up to 600 V) for machine, tool and plant construction. Suitable for medium mechanical stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Designed for export-oriented mechanical engineers, specifically in the USA and Canada. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e12 AWG 7C Shielded Control Cable CY PVC Control Cable Flexible EMC Control Cable Shielded Connection Cable Industrial Automation Cable PVC Flexible Control Cable Braided Shield Control Cable Tinned 12 AWG 7C Copper Shielded Cable UL\/CSA Approved Control Cable 600V Flexible Control Cable Oil-Resistant Control Cable Machine Tool Control Cable EMC Preferred Type Cable Flexible Signal \u0026amp; Control Cable Multi-Core Shielded Cable Grey Jacket 12 AWG 7C Control Cable Grounded Control Cable JZ-602-CY Ungrounded Control Cable Industrial Connection Cable Flexible Power and Control Cable\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable acc. to UL-Std. 758 (AWM) Style 2587, CSA-Std. C22.2 No. 210 - AWM I\/II A\/B\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -10°C to +90°C\u003cbr\u003efixed -40°C to +90°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eUL (AWM) AC 600 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e3000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e6000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 10x Outer-Ø\u003cbr\u003efixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to UL-Std. 758 (AWM) Style 11008, CSA-Std. C22.2 No. 210\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003e x = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2, UL VW-1, CSA FT1\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are\u003cbr\u003eapproximated, and are for reference only\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size :\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e12 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 7 G 4\u003cb\u003e\u003cbr\u003e• Outer-Ø min - max mm:\u003c\/b\u003e 15.8\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 316.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 737.0\u003cbr\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63574968435057,"sku":"NNC82958","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_f926c033-48fb-4ba6-bf43-18a3ad56bdb8.png?v=1778233359"},{"product_id":"10-awg-2c-helukabel-82949-oz-602-cy-pvc-control-and-connection-cable","title":"10 AWG 2C HELUKABEL 82949 OZ-602-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M82990_EN_GB_1.pdf?v=1778137952\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e10 AWG 2C HELUKABEL 82949 OZ-602-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUL\/CSA approved, flexible control cable (up to 600 V) for machine, tool and plant construction. Suitable for medium mechanical stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Designed for export-oriented mechanical engineers, specifically in the USA and Canada. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e10 AWG 2C Shielded Control Cable CY PVC Control Cable Flexible EMC Control Cable Shielded Connection Cable Industrial Automation Cable PVC Flexible Control Cable Braided Shield Control Cable Tinned 10 AWG 2C Copper Shielded Cable UL\/CSA Approved Control Cable 600V Flexible Control Cable Oil-Resistant Control Cable Machine Tool Control Cable EMC Preferred Type Cable Flexible Signal \u0026amp; Control Cable Multi-Core Shielded Cable Grey Jacket 10 AWG 2C Control Cable Grounded Control Cable OZ-602-CY Ungrounded Control Cable Industrial Connection Cable Flexible Power and Control Cable\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable acc. to UL-Std. 758 (AWM) Style 2587, CSA-Std. C22.2 No. 210 - AWM I\/II A\/B\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -10°C to +90°C\u003cbr\u003efixed -40°C to +90°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eUL (AWM) AC 600 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e3000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e6000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 10x Outer-Ø\u003cbr\u003efixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to UL-Std. 758 (AWM) Style 11008, CSA-Std. C22.2 No. 210\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003e x = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2, UL VW-1, CSA FT1\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are\u003cbr\u003eapproximated, and are for reference only\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size :\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e10 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 2 x 6\u003cb\u003e\u003cbr\u003e• Outer-Ø min - max mm:\u003c\/b\u003e 13.4\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 173.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 318.0\u003cbr\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63574984327537,"sku":"NNC82949","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design-Photoroom_ccb672b8-cb07-4f55-aa42-29730b1643f7.png?v=1778235234"},{"product_id":"10-awg-3c-helukabel-82950-jz-602-cy-pvc-control-and-connection-cable","title":"10 AWG 3C HELUKABEL 82950 JZ-602-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M82990_EN_GB_1.pdf?v=1778137952\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e10 AWG 3C HELUKABEL 82950 JZ-602-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUL\/CSA approved, flexible control cable (up to 600 V) for machine, tool and plant construction. Suitable for medium mechanical stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Designed for export-oriented mechanical engineers, specifically in the USA and Canada. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003e10 AWG 3C Shielded Control Cable CY PVC Control Cable Flexible EMC Control Cable Shielded Connection Cable Industrial Automation Cable PVC Flexible Control Cable Braided Shield Control Cable Tinned 10 AWG 3C Copper Shielded Cable UL\/CSA Approved Control Cable 600V Flexible Control Cable Oil-Resistant Control Cable Machine Tool Control Cable EMC Preferred Type Cable Flexible Signal \u0026amp; Control Cable Multi-Core Shielded Cable Grey Jacket 10 AWG 3C Control Cable Grounded Control Cable JZ-602-CY Ungrounded Control Cable Industrial Connection Cable Flexible Power and Control Cable\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable acc. to UL-Std. 758 (AWM) Style 2587, CSA-Std. C22.2 No. 210 - AWM I\/II A\/B\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -10°C to +90°C\u003cbr\u003efixed -40°C to +90°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eUL (AWM) AC 600 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e3000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e6000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/km\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 10x Outer-Ø\u003cbr\u003efixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to UL-Std. 758 (AWM) Style 11008, CSA-Std. C22.2 No. 210\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003e x = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to UL-Std. 758 (AWM) Style 2587, CSAStd. C22.2 No. 210\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2, UL VW-1, CSA FT1\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are\u003cbr\u003eapproximated, and are for reference only\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e• Size :\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e10 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 3 G 6\u003cb\u003e\u003cbr\u003e• Outer-Ø min - max mm:\u003c\/b\u003e 14.3\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 240.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 411.0\u003cbr\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63591230112113,"sku":"NNC82950","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_d9cd8fd0-4bfb-4092-87a7-5b51e784e195.png?v=1778219906"}],"url":"https:\/\/nassaunationalcable.com\/collections\/helukabel-jz-602-cy-oz-602-cy-pvc-control-and-connection-cable.oembed?page=4","provider":"NassauNationalCable","version":"1.0","type":"link"}