{"title":"HELUKABEL JZ-600-Y-CY \/ OZ-600-Y-CY PVC CONTROL AND CONNECTION CABLE","description":"\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003eHELUKABEL JZ-600-Y-CY \/ OZ-600-Y-CY PVC CONTROL AND CONNECTION CABLE\u003c\/span\u003e\u003c\/h2\u003e","products":[{"product_id":"helukabel-jz-600-y-cy-oz-600-y-cy-pvc-control-and-connection-cable","title":"HELUKABEL JZ-600-Y-CY \/ OZ-600-Y-CY PVC CONTROL AND CONNECTION CABLE","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11464_EN_GB_1.pdf?v=1772609466\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003eHELUKABEL JZ-600-Y-CY \/ OZ-600-Y-CY PVC CONTROL AND CONNECTION CABLE\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a connection and control cable in machine tools, assembly lines and conveyor belts, production lines, plant construction, heating and air-conditioning technology and in smelters and steel mills. Suitable for flexible applications involving medium mechanical\u003cbr\u003estress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, as well as outdoors (fixed installation). May not be laid directly in soil (suitable for direct burial starting with an outer diameter of 20 mm) or water. Due to its extended nominal voltage range and good UV resistance, this cable is primarily used in Southern Europe, Arabic, Asian and Eastern countries. Due to the high screening density, interference-free transmission of signals or pulses is ensured. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding. \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-start=\"132\" data-end=\"162\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-start=\"124\" data-end=\"153\"\u003eJZ 600 Y CY Control Cable OZ 600 Y CY Control Cable PVC Shielded Control Cable Flexible PVC Connection Cable JZ \/ OZ Series Control Cable Shielded PVC Control Cable Flexible PVC Armored Cable JZ 600-Y PVC Control Cable OZ 600-Y PVC Control Cable JZ \/ OZ PVC Shielded Cable PVC CY Shielded Control Cable Flexible Shielded Connection Cable\u003cstrong data-start=\"257\" data-end=\"289\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable in alignment with DIN VDE 0262, DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eFlexible -15°C to +80°C\u003cbr\u003eFixed -40°C to +80°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 600\/1000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e8000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eFlexible 10x Outer-Ø\u003cbr\u003eFixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: black (RAL 9005)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Resistant to: UV radiation, weathering effects\u003cbr\u003e• Largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• For outdoor use\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• UV-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Weather-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63255532831089,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_4e82bb65-cea0-4c86-9801-f624f9494a3b.png?v=1772609269"},{"product_id":"20-awg-2c-helukabel-11464-oz-600-y-cy-pvc-control-and-connection-cable","title":"20 AWG 2C Helukabel 11464 OZ-600-Y-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11464_EN_GB_1.pdf?v=1772609466\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 2C Helukabel 11464 OZ-600-Y-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a connection and control cable in machine tools, assembly lines and conveyor belts, production lines, plant construction, heating and air-conditioning technology and in smelters and steel mills. Suitable for flexible applications involving medium mechanical\u003cbr\u003estress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, as well as outdoors (fixed installation). May not be laid directly in soil (suitable for direct burial starting with an outer diameter of 20 mm) or water. Due to its extended nominal voltage range and good UV resistance, this cable is primarily used in Southern Europe, Arabic, Asian and Eastern countries. Due to the high screening density, interference-free transmission of signals or pulses is ensured. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding. \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"153\" data-start=\"124\"\u003e20 AWG 2C OZ 600 Y CY Control Cable OZ 600 Y CY Control Cable PVC Shielded Control Cable Flexible PVC Connection Cable Series 20 AWG 2C Control Cable Shielded PVC Control Cable Flexible PVC Armored Cable OZ 600-Y PVC Control Cable OZ 600-Y PVC 20 AWG 2C Control Cable PVC Shielded Cable PVC CY Shielded Control Cable Flexible Shielded Connection Cable\u003cstrong data-end=\"289\" data-start=\"257\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable in alignment with DIN VDE 0262, DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eFlexible -15°C to +80°C\u003cbr\u003eFixed -40°C to +80°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 600\/1000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e8000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eFlexible 10x Outer-Ø\u003cbr\u003eFixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: black (RAL 9005)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Resistant to: UV radiation, weathering effects\u003cbr\u003e• Largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• For outdoor use\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• UV-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Weather-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size :\u003c\/b\u003e 20 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 2 x 0.5\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e8.4\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 41.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 115.0\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63255569301873,"sku":"NNC11464","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design-Photoroom_18cefce1-b378-421c-b92c-b497011d1240.png?v=1772610130"},{"product_id":"20-awg-3c-helukabel-11465-jz-600-y-cy-pvc-control-and-connection-cable","title":"20 AWG 3C Helukabel 11465 JZ-600-Y-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11464_EN_GB_1.pdf?v=1772609466\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 3C Helukabel 11465 JZ-600-Y-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a connection and control cable in machine tools, assembly lines and conveyor belts, production lines, plant construction, heating and air-conditioning technology and in smelters and steel mills. Suitable for flexible applications involving medium mechanical\u003cbr\u003estress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, as well as outdoors (fixed installation). May not be laid directly in soil (suitable for direct burial starting with an outer diameter of 20 mm) or water. Due to its extended nominal voltage range and good UV resistance, this cable is primarily used in Southern Europe, Arabic, Asian and Eastern countries. Due to the high screening density, interference-free transmission of signals or pulses is ensured. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding. \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-start=\"132\" data-end=\"162\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-start=\"124\" data-end=\"153\"\u003e20 AWG 3C JZ 600 Y CY Control Cable JZ 600 Y CY Control Cable PVC Shielded Control Cable Flexible PVC Connection Cable Series 20 AWG 3C Control Cable Shielded PVC Control Cable Flexible PVC Armored Cable 20 AWG 3C JZ 600-Y PVC Control Cable JZ 600-Y PVC  Control Cable PVC Shielded Cable PVC CY Shielded Control Cable Flexible Shielded Connection Cable\u003cstrong data-start=\"257\" data-end=\"289\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable in alignment with DIN VDE 0262, DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eFlexible -15°C to +80°C\u003cbr\u003eFixed -40°C to +80°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 600\/1000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e8000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eFlexible 10x Outer-Ø\u003cbr\u003eFixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: black (RAL 9005)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Resistant to: UV radiation, weathering effects\u003cbr\u003e• Largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• For outdoor use\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• UV-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Weather-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size :\u003c\/b\u003e 20 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 3 G 0.5\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e8.8\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 45.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 127.0\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63255595123057,"sku":"NNC11465","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_afa32979-c31a-49a3-81f7-8c857d95172b.png?v=1772621095"},{"product_id":"20-awg-4c-helukabel-11466-jz-600-y-cy-pvc-control-and-connection-cable","title":"20 AWG 4C Helukabel 11466 JZ-600-Y-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11464_EN_GB_1.pdf?v=1772609466\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 4C Helukabel 11466 JZ-600-Y-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a connection and control cable in machine tools, assembly lines and conveyor belts, production lines, plant construction, heating and air-conditioning technology and in smelters and steel mills. Suitable for flexible applications involving medium mechanical\u003cbr\u003estress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, as well as outdoors (fixed installation). May not be laid directly in soil (suitable for direct burial starting with an outer diameter of 20 mm) or water. Due to its extended nominal voltage range and good UV resistance, this cable is primarily used in Southern Europe, Arabic, Asian and Eastern countries. Due to the high screening density, interference-free transmission of signals or pulses is ensured. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding. \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-start=\"132\" data-end=\"162\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-start=\"124\" data-end=\"153\"\u003e20 AWG 4C JZ 600 Y CY Control Cable JZ 600 Y CY Control Cable PVC Shielded Control Cable Flexible PVC Connection Cable Series 20 AWG 4C Control Cable Shielded PVC Control Cable Flexible PVC Armored Cable 20 AWG 4C JZ 600-Y PVC Control Cable JZ 600-Y PVC  Control Cable PVC Shielded Cable PVC CY Shielded Control Cable Flexible Shielded Connection Cable\u003cstrong data-start=\"257\" data-end=\"289\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable in alignment with DIN VDE 0262, DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eFlexible -15°C to +80°C\u003cbr\u003eFixed -40°C to +80°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 600\/1000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e8000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eFlexible 10x Outer-Ø\u003cbr\u003eFixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: black (RAL 9005)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Resistant to: UV radiation, weathering effects\u003cbr\u003e• Largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• For outdoor use\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• UV-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Weather-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size :\u003c\/b\u003e 20 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 4 G 0.5\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e9.3\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 54.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 149.0\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63255653777777,"sku":"NNC11466","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_afa32979-c31a-49a3-81f7-8c857d95172b.png?v=1772621095"},{"product_id":"20-awg-5c-helukabel-11467-jz-600-y-cy-pvc-control-and-connection-cable","title":"20 AWG 5C Helukabel 11467 JZ-600-Y-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11464_EN_GB_1.pdf?v=1772609466\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 5C Helukabel 11467 JZ-600-Y-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a connection and control cable in machine tools, assembly lines and conveyor belts, production lines, plant construction, heating and air-conditioning technology and in smelters and steel mills. Suitable for flexible applications involving medium mechanical\u003cbr\u003estress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, as well as outdoors (fixed installation). May not be laid directly in soil (suitable for direct burial starting with an outer diameter of 20 mm) or water. Due to its extended nominal voltage range and good UV resistance, this cable is primarily used in Southern Europe, Arabic, Asian and Eastern countries. Due to the high screening density, interference-free transmission of signals or pulses is ensured. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding. \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-start=\"132\" data-end=\"162\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-start=\"124\" data-end=\"153\"\u003e20 AWG 5C JZ 600 Y CY Control Cable JZ 600 Y CY Control Cable PVC Shielded Control Cable Flexible PVC Connection Cable Series 20 AWG 5C Control Cable Shielded PVC Control Cable Flexible PVC Armored Cable 20 AWG 5C JZ 600-Y PVC Control Cable JZ 600-Y PVC  Control Cable PVC Shielded Cable PVC CY Shielded Control Cable Flexible Shielded Connection Cable\u003cstrong data-start=\"257\" data-end=\"289\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable in alignment with DIN VDE 0262, DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eFlexible -15°C to +80°C\u003cbr\u003eFixed -40°C to +80°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 600\/1000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e8000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eFlexible 10x Outer-Ø\u003cbr\u003eFixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: black (RAL 9005)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Resistant to: UV radiation, weathering effects\u003cbr\u003e• Largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• For outdoor use\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• UV-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Weather-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size :\u003c\/b\u003e 20 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 5 G 0.5\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e10.1\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 66.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 169.0\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63255807492465,"sku":"NNC11467","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_afa32979-c31a-49a3-81f7-8c857d95172b.png?v=1772621095"},{"product_id":"20-awg-7c-helukabel-11469-jz-600-y-cy-pvc-control-and-connection-cable","title":"20 AWG 7C Helukabel 11469 JZ-600-Y-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11464_EN_GB_1.pdf?v=1772609466\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 7C Helukabel 11469 JZ-600-Y-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a connection and control cable in machine tools, assembly lines and conveyor belts, production lines, plant construction, heating and air-conditioning technology and in smelters and steel mills. Suitable for flexible applications involving medium mechanical\u003cbr\u003estress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, as well as outdoors (fixed installation). May not be laid directly in soil (suitable for direct burial starting with an outer diameter of 20 mm) or water. Due to its extended nominal voltage range and good UV resistance, this cable is primarily used in Southern Europe, Arabic, Asian and Eastern countries. Due to the high screening density, interference-free transmission of signals or pulses is ensured. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding. \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"153\" data-start=\"124\"\u003e20 AWG 7C JZ 600 Y CY Control Cable JZ 600 Y CY Control Cable PVC Shielded Control Cable Flexible PVC Connection Cable Series 20 AWG 7C Control Cable Shielded PVC Control Cable Flexible PVC Armored Cable 20 AWG 7C JZ 600-Y PVC Control Cable JZ 600-Y PVC  Control Cable PVC Shielded Cable PVC CY Shielded Control Cable Flexible Shielded Connection Cable\u003cstrong data-end=\"289\" data-start=\"257\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable in alignment with DIN VDE 0262, DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eFlexible -15°C to +80°C\u003cbr\u003eFixed -40°C to +80°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 600\/1000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e8000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eFlexible 10x Outer-Ø\u003cbr\u003eFixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: black (RAL 9005)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Resistant to: UV radiation, weathering effects\u003cbr\u003e• Largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• For outdoor use\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• UV-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Weather-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size :\u003c\/b\u003e 20 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 7 G 0.5\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e10.9\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 79.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 230.0\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63255818010993,"sku":"NNC11469","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_afa32979-c31a-49a3-81f7-8c857d95172b.png?v=1772621095"},{"product_id":"20-awg-12c-helukabel-11472-jz-600-y-cy-pvc-control-and-connection-cable","title":"20 AWG 12C Helukabel 11472 JZ-600-Y-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11464_EN_GB_1.pdf?v=1772609466\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 12C Helukabel 11472 JZ-600-Y-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a connection and control cable in machine tools, assembly lines and conveyor belts, production lines, plant construction, heating and air-conditioning technology and in smelters and steel mills. Suitable for flexible applications involving medium mechanical\u003cbr\u003estress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, as well as outdoors (fixed installation). May not be laid directly in soil (suitable for direct burial starting with an outer diameter of 20 mm) or water. Due to its extended nominal voltage range and good UV resistance, this cable is primarily used in Southern Europe, Arabic, Asian and Eastern countries. Due to the high screening density, interference-free transmission of signals or pulses is ensured. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding. \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"153\" data-start=\"124\"\u003e20 AWG 12C JZ 600 Y CY Control Cable JZ 600 Y CY Control Cable PVC Shielded Control Cable Flexible PVC Connection Cable Series 20 AWG 12C Control Cable Shielded PVC Control Cable Flexible PVC Armored Cable 20 AWG 12C JZ 600-Y PVC Control Cable JZ 600-Y PVC  Control Cable PVC Shielded Cable PVC CY Shielded Control Cable Flexible Shielded Connection Cable\u003cstrong data-end=\"289\" data-start=\"257\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable in alignment with DIN VDE 0262, DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eFlexible -15°C to +80°C\u003cbr\u003eFixed -40°C to +80°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 600\/1000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e8000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eFlexible 10x Outer-Ø\u003cbr\u003eFixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: black (RAL 9005)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Resistant to: UV radiation, weathering effects\u003cbr\u003e• Largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• For outdoor use\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• UV-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Weather-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size :\u003c\/b\u003e 20 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 12 G 0.5\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e14.0\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 137.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 386.0\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63255831118193,"sku":"NNC11472","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_afa32979-c31a-49a3-81f7-8c857d95172b.png?v=1772621095"},{"product_id":"20-awg-18c-helukabel-11475-jz-600-y-cy-pvc-control-and-connection-cable","title":"20 AWG 18C Helukabel 11475 JZ-600-Y-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11464_EN_GB_1.pdf?v=1772609466\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 18C Helukabel 11475 JZ-600-Y-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a connection and control cable in machine tools, assembly lines and conveyor belts, production lines, plant construction, heating and air-conditioning technology and in smelters and steel mills. Suitable for flexible applications involving medium mechanical\u003cbr\u003estress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, as well as outdoors (fixed installation). May not be laid directly in soil (suitable for direct burial starting with an outer diameter of 20 mm) or water. Due to its extended nominal voltage range and good UV resistance, this cable is primarily used in Southern Europe, Arabic, Asian and Eastern countries. Due to the high screening density, interference-free transmission of signals or pulses is ensured. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding. \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"153\" data-start=\"124\"\u003e20 AWG 18C JZ 600 Y CY Control Cable JZ 600 Y CY Control Cable PVC Shielded Control Cable Flexible PVC Connection Cable Series 20 AWG 18C Control Cable Shielded PVC Control Cable Flexible PVC Armored Cable 20 AWG 18C JZ 600-Y PVC Control Cable JZ 600-Y PVC  Control Cable PVC Shielded Cable PVC CY Shielded Control Cable Flexible Shielded Connection Cable\u003cstrong data-end=\"289\" data-start=\"257\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable in alignment with DIN VDE 0262, DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eFlexible -15°C to +80°C\u003cbr\u003eFixed -40°C to +80°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 600\/1000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e8000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eFlexible 10x Outer-Ø\u003cbr\u003eFixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: black (RAL 9005)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Resistant to: UV radiation, weathering effects\u003cbr\u003e• Largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• For outdoor use\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• UV-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Weather-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size :\u003c\/b\u003e 20 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 18 G 0.5\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e16.3\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 156.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 428.0\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63255837344113,"sku":"NNC11475","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_afa32979-c31a-49a3-81f7-8c857d95172b.png?v=1772621095"},{"product_id":"20-awg-25c-helukabel-11478-jz-600-y-cy-pvc-control-and-connection-cable","title":"20 AWG 25C Helukabel 11478 JZ-600-Y-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11464_EN_GB_1.pdf?v=1772609466\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 25C Helukabel 11478 JZ-600-Y-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a connection and control cable in machine tools, assembly lines and conveyor belts, production lines, plant construction, heating and air-conditioning technology and in smelters and steel mills. Suitable for flexible applications involving medium mechanical\u003cbr\u003estress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, as well as outdoors (fixed installation). May not be laid directly in soil (suitable for direct burial starting with an outer diameter of 20 mm) or water. Due to its extended nominal voltage range and good UV resistance, this cable is primarily used in Southern Europe, Arabic, Asian and Eastern countries. Due to the high screening density, interference-free transmission of signals or pulses is ensured. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding. \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"153\" data-start=\"124\"\u003e20 AWG 25C JZ 600 Y CY Control Cable JZ 600 Y CY Control Cable PVC Shielded Control Cable Flexible PVC Connection Cable Series 20 AWG 25C Control Cable Shielded PVC Control Cable Flexible PVC Armored Cable 20 AWG 25C JZ 600-Y PVC Control Cable JZ 600-Y PVC  Control Cable PVC Shielded Cable PVC CY Shielded Control Cable Flexible Shielded Connection Cable\u003cstrong data-end=\"289\" data-start=\"257\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable in alignment with DIN VDE 0262, DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eFlexible -15°C to +80°C\u003cbr\u003eFixed -40°C to +80°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 600\/1000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e8000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eFlexible 10x Outer-Ø\u003cbr\u003eFixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: black (RAL 9005)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Resistant to: UV radiation, weathering effects\u003cbr\u003e• Largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• For outdoor use\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• UV-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Weather-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size :\u003c\/b\u003e 20 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 25 G 0.5\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e19.0 \u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 250.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 693.0\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63255842324849,"sku":"NNC11478","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_afa32979-c31a-49a3-81f7-8c857d95172b.png?v=1772621095"},{"product_id":"19-awg-2c-helukabel-11489-oz-600-y-cy-pvc-control-and-connection-cable-1","title":"19 AWG 2C Helukabel 11489 OZ-600-Y-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11464_EN_GB_1.pdf?v=1772609466\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e19 AWG 2C Helukabel 11489 OZ-600-Y-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a connection and control cable in machine tools, assembly lines and conveyor belts, production lines, plant construction, heating and air-conditioning technology and in smelters and steel mills. Suitable for flexible applications involving medium mechanical\u003cbr\u003estress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, as well as outdoors (fixed installation). May not be laid directly in soil (suitable for direct burial starting with an outer diameter of 20 mm) or water. Due to its extended nominal voltage range and good UV resistance, this cable is primarily used in Southern Europe, Arabic, Asian and Eastern countries. Due to the high screening density, interference-free transmission of signals or pulses is ensured. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding. \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"153\" data-start=\"124\"\u003e19 AWG 2C OZ 600 Y CY Control Cable OZ 600 Y CY Control Cable PVC Shielded Control Cable Flexible PVC Connection Cable Series 19 AWG 2C Control Cable Shielded PVC Control Cable Flexible PVC Armored Cable OZ 600-Y PVC Control Cable OZ 600-Y PVC \u003cbr\u003e19 AWG 2C Control Cable PVC Shielded Cable PVC CY Shielded Control Cable Flexible Shielded Connection Cable\u003cstrong data-end=\"289\" data-start=\"257\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable in alignment with DIN VDE 0262, DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eFlexible -15°C to +80°C\u003cbr\u003eFixed -40°C to +80°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 600\/1000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e8000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eFlexible 10x Outer-Ø\u003cbr\u003eFixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: black (RAL 9005)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Resistant to: UV radiation, weathering effects\u003cbr\u003e• Largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• For outdoor use\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• UV-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Weather-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size :\u003c\/b\u003e 19 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 2 x 0.75\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e8.9\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 46.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 128.0\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63255859790193,"sku":"NNC11489","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design-Photoroom_baecf753-6698-47bc-9db3-f711026d37bb.png?v=1772689423"},{"product_id":"19-awg-3c-helukabel-11490-jz-600-y-cy-pvc-control-and-connection-cable","title":"19 AWG 3C Helukabel 11490 JZ-600-Y-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11464_EN_GB_1.pdf?v=1772609466\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e19 AWG 3C Helukabel 11490 JZ-600-Y-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a connection and control cable in machine tools, assembly lines and conveyor belts, production lines, plant construction, heating and air-conditioning technology and in smelters and steel mills. Suitable for flexible applications involving medium mechanical\u003cbr\u003estress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, as well as outdoors (fixed installation). May not be laid directly in soil (suitable for direct burial starting with an outer diameter of 20 mm) or water. Due to its extended nominal voltage range and good UV resistance, this cable is primarily used in Southern Europe, Arabic, Asian and Eastern countries. Due to the high screening density, interference-free transmission of signals or pulses is ensured. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding. \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"153\" data-start=\"124\"\u003e19 AWG 3C JZ 600 Y CY Control Cable JZ 600 Y CY Control Cable PVC Shielded Control Cable Flexible PVC Connection Cable Series 19 AWG 3C Control Cable Shielded PVC Control Cable Flexible PVC Armored Cable 19 AWG 3C JZ 600-Y PVC Control Cable JZ 600-Y PVC  Control Cable PVC Shielded Cable PVC CY Shielded Control Cable Flexible Shielded Connection Cable\u003cstrong data-end=\"289\" data-start=\"257\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable in alignment with DIN VDE 0262, DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eFlexible -15°C to +80°C\u003cbr\u003eFixed -40°C to +80°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 600\/1000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e8000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eFlexible 10x Outer-Ø\u003cbr\u003eFixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: black (RAL 9005)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Resistant to: UV radiation, weathering effects\u003cbr\u003e• Largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• For outdoor use\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• UV-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Weather-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size :\u003c\/b\u003e 19 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 3 G 0.75\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e9.3\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 57.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 143.0\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63255866638705,"sku":"NNC11490","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_afa32979-c31a-49a3-81f7-8c857d95172b.png?v=1772621095"},{"product_id":"19-awg-4c-helukabel-11491-jz-600-y-cy-pvc-control-and-connection-cable","title":"19 AWG 4C Helukabel 11491 JZ-600-Y-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11464_EN_GB_1.pdf?v=1772609466\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e19 AWG 4C Helukabel 11491 JZ-600-Y-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a connection and control cable in machine tools, assembly lines and conveyor belts, production lines, plant construction, heating and air-conditioning technology and in smelters and steel mills. Suitable for flexible applications involving medium mechanical\u003cbr\u003estress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, as well as outdoors (fixed installation). May not be laid directly in soil (suitable for direct burial starting with an outer diameter of 20 mm) or water. Due to its extended nominal voltage range and good UV resistance, this cable is primarily used in Southern Europe, Arabic, Asian and Eastern countries. Due to the high screening density, interference-free transmission of signals or pulses is ensured. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding. \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-start=\"132\" data-end=\"162\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-start=\"124\" data-end=\"153\"\u003e19 AWG 4C JZ 600 Y CY Control Cable JZ 600 Y CY Control Cable PVC Shielded Control Cable Flexible PVC Connection Cable Series 19 AWG 4C Control Cable Shielded PVC Control Cable Flexible PVC Armored Cable 19 AWG 4C JZ 600-Y PVC Control Cable JZ 600-Y PVC  Control Cable PVC Shielded Cable PVC CY Shielded Control Cable Flexible Shielded Connection Cable\u003cstrong data-start=\"257\" data-end=\"289\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable in alignment with DIN VDE 0262, DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eFlexible -15°C to +80°C\u003cbr\u003eFixed -40°C to +80°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 600\/1000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e8000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eFlexible 10x Outer-Ø\u003cbr\u003eFixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: black (RAL 9005)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Resistant to: UV radiation, weathering effects\u003cbr\u003e• Largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• For outdoor use\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• UV-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Weather-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size :\u003c\/b\u003e 19 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 4 G 0.75\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e10.1\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 63.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 164.0\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63255882203505,"sku":"NNC11491","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_afa32979-c31a-49a3-81f7-8c857d95172b.png?v=1772621095"},{"product_id":"19-awg-5c-helukabel-11492-jz-600-y-cy-pvc-control-and-connection-cable","title":"19 AWG 5C Helukabel 11492 JZ-600-Y-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11464_EN_GB_1.pdf?v=1772609466\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e19 AWG 5C Helukabel 11492 JZ-600-Y-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a connection and control cable in machine tools, assembly lines and conveyor belts, production lines, plant construction, heating and air-conditioning technology and in smelters and steel mills. Suitable for flexible applications involving medium mechanical\u003cbr\u003estress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, as well as outdoors (fixed installation). May not be laid directly in soil (suitable for direct burial starting with an outer diameter of 20 mm) or water. Due to its extended nominal voltage range and good UV resistance, this cable is primarily used in Southern Europe, Arabic, Asian and Eastern countries. Due to the high screening density, interference-free transmission of signals or pulses is ensured. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding. \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-start=\"132\" data-end=\"162\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-start=\"124\" data-end=\"153\"\u003e19 AWG 5C JZ 600 Y CY Control Cable JZ 600 Y CY Control Cable PVC Shielded Control Cable Flexible PVC Connection Cable Series 19 AWG 5C Control Cable Shielded PVC Control Cable Flexible PVC Armored Cable 19 AWG 5C JZ 600-Y PVC Control Cable JZ 600-Y PVC  Control Cable PVC Shielded Cable PVC CY Shielded Control Cable Flexible Shielded Connection Cable\u003cstrong data-start=\"257\" data-end=\"289\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable in alignment with DIN VDE 0262, DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eFlexible -15°C to +80°C\u003cbr\u003eFixed -40°C to +80°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 600\/1000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e8000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eFlexible 10x Outer-Ø\u003cbr\u003eFixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: black (RAL 9005)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Resistant to: UV radiation, weathering effects\u003cbr\u003e• Largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• For outdoor use\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• UV-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Weather-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size :\u003c\/b\u003e 19 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 5 G 0.75\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e11.0\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 76.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 198.0\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63258007503217,"sku":"NNC11492","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_afa32979-c31a-49a3-81f7-8c857d95172b.png?v=1772621095"},{"product_id":"19-awg-7c-helukabel-11494-jz-600-y-cy-pvc-control-and-connection-cable","title":"19 AWG 7C Helukabel 11494 JZ-600-Y-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11464_EN_GB_1.pdf?v=1772609466\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e19 AWG 7C Helukabel 11494 JZ-600-Y-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a connection and control cable in machine tools, assembly lines and conveyor belts, production lines, plant construction, heating and air-conditioning technology and in smelters and steel mills. Suitable for flexible applications involving medium mechanical\u003cbr\u003estress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, as well as outdoors (fixed installation). May not be laid directly in soil (suitable for direct burial starting with an outer diameter of 20 mm) or water. Due to its extended nominal voltage range and good UV resistance, this cable is primarily used in Southern Europe, Arabic, Asian and Eastern countries. Due to the high screening density, interference-free transmission of signals or pulses is ensured. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding. \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-start=\"132\" data-end=\"162\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-start=\"124\" data-end=\"153\"\u003e19 AWG 7C JZ 600 Y CY Control Cable JZ 600 Y CY Control Cable PVC Shielded Control Cable Flexible PVC Connection Cable Series 19 AWG 7C Control Cable Shielded PVC Control Cable Flexible PVC Armored Cable 19 AWG 7C JZ 600-Y PVC Control Cable JZ 600-Y PVC  Control Cable PVC Shielded Cable PVC CY Shielded Control Cable Flexible Shielded Connection Cable\u003cstrong data-start=\"257\" data-end=\"289\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable in alignment with DIN VDE 0262, DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eFlexible -15°C to +80°C\u003cbr\u003eFixed -40°C to +80°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 600\/1000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e8000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eFlexible 10x Outer-Ø\u003cbr\u003eFixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: black (RAL 9005)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Resistant to: UV radiation, weathering effects\u003cbr\u003e• Largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• For outdoor use\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• UV-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Weather-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size :\u003c\/b\u003e 19 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 7 G 0.75\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e11.9\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 100.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 232.0\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63258008060273,"sku":"NNC11494","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_afa32979-c31a-49a3-81f7-8c857d95172b.png?v=1772621095"},{"product_id":"19-awg-12c-helukabel-11498-jz-600-y-cy-pvc-control-and-connection-cable","title":"19 AWG 12C Helukabel 11498 JZ-600-Y-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11464_EN_GB_1.pdf?v=1772609466\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e19 AWG 12C Helukabel 11498 JZ-600-Y-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a connection and control cable in machine tools, assembly lines and conveyor belts, production lines, plant construction, heating and air-conditioning technology and in smelters and steel mills. Suitable for flexible applications involving medium mechanical\u003cbr\u003estress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, as well as outdoors (fixed installation). May not be laid directly in soil (suitable for direct burial starting with an outer diameter of 20 mm) or water. Due to its extended nominal voltage range and good UV resistance, this cable is primarily used in Southern Europe, Arabic, Asian and Eastern countries. Due to the high screening density, interference-free transmission of signals or pulses is ensured. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding. \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-start=\"132\" data-end=\"162\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-start=\"124\" data-end=\"153\"\u003e19 AWG 12C JZ 600 Y CY Control Cable JZ 600 Y CY Control Cable PVC Shielded Control Cable Flexible PVC Connection Cable Series 19 AWG 12C Control Cable Shielded PVC Control Cable Flexible PVC Armored Cable 19 AWG 12C JZ 600-Y PVC Control Cable JZ 600-Y PVC  Control Cable PVC Shielded Cable PVC CY Shielded Control Cable Flexible Shielded Connection Cable\u003cstrong data-start=\"257\" data-end=\"289\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable in alignment with DIN VDE 0262, DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eFlexible -15°C to +80°C\u003cbr\u003eFixed -40°C to +80°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 600\/1000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e8000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eFlexible 10x Outer-Ø\u003cbr\u003eFixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: black (RAL 9005)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Resistant to: UV radiation, weathering effects\u003cbr\u003e• Largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• For outdoor use\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• UV-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Weather-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size :\u003c\/b\u003e 19 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 12 G 0.75\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e15.4\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 175.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 360.0\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63258009010545,"sku":"NNC11498","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_afa32979-c31a-49a3-81f7-8c857d95172b.png?v=1772621095"},{"product_id":"19-awg-18c-helukabel-11501-jz-600-y-cy-pvc-control-and-connection-cable","title":"19 AWG 18C Helukabel 11501 JZ-600-Y-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11464_EN_GB_1.pdf?v=1772609466\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e19 AWG 18C Helukabel 11501 JZ-600-Y-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a connection and control cable in machine tools, assembly lines and conveyor belts, production lines, plant construction, heating and air-conditioning technology and in smelters and steel mills. Suitable for flexible applications involving medium mechanical\u003cbr\u003estress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, as well as outdoors (fixed installation). May not be laid directly in soil (suitable for direct burial starting with an outer diameter of 20 mm) or water. Due to its extended nominal voltage range and good UV resistance, this cable is primarily used in Southern Europe, Arabic, Asian and Eastern countries. Due to the high screening density, interference-free transmission of signals or pulses is ensured. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding. \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-start=\"132\" data-end=\"162\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-start=\"124\" data-end=\"153\"\u003e19 AWG 18C JZ 600 Y CY Control Cable JZ 600 Y CY Control Cable PVC Shielded Control Cable Flexible PVC Connection Cable Series 19 AWG 18C Control Cable Shielded PVC Control Cable Flexible PVC Armored Cable 19 AWG 18C JZ 600-Y PVC Control Cable JZ 600-Y PVC  Control Cable PVC Shielded Cable PVC CY Shielded Control Cable Flexible Shielded Connection Cable\u003cstrong data-start=\"257\" data-end=\"289\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable in alignment with DIN VDE 0262, DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eFlexible -15°C to +80°C\u003cbr\u003eFixed -40°C to +80°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 600\/1000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e8000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eFlexible 10x Outer-Ø\u003cbr\u003eFixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: black (RAL 9005)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Resistant to: UV radiation, weathering effects\u003cbr\u003e• Largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• For outdoor use\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• UV-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Weather-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size :\u003c\/b\u003e 19 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 18 G 0.75\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e18.0\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 240.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 562.0\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63258039976305,"sku":"NNC11501","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_afa32979-c31a-49a3-81f7-8c857d95172b.png?v=1772621095"},{"product_id":"19-awg-25c-helukabel-11504-jz-600-y-cy-pvc-control-and-connection-cable","title":"19 AWG 25C Helukabel 11504 JZ-600-Y-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11464_EN_GB_1.pdf?v=1772609466\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e19 AWG 25C Helukabel 11504 JZ-600-Y-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a connection and control cable in machine tools, assembly lines and conveyor belts, production lines, plant construction, heating and air-conditioning technology and in smelters and steel mills. Suitable for flexible applications involving medium mechanical\u003cbr\u003estress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, as well as outdoors (fixed installation). May not be laid directly in soil (suitable for direct burial starting with an outer diameter of 20 mm) or water. Due to its extended nominal voltage range and good UV resistance, this cable is primarily used in Southern Europe, Arabic, Asian and Eastern countries. Due to the high screening density, interference-free transmission of signals or pulses is ensured. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding. \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-start=\"132\" data-end=\"162\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-start=\"124\" data-end=\"153\"\u003e19 AWG 25C JZ 600 Y CY Control Cable JZ 600 Y CY Control Cable PVC Shielded Control Cable Flexible PVC Connection Cable Series 19 AWG 25C Control Cable Shielded PVC Control Cable Flexible PVC Armored Cable 19 AWG 25C JZ 600-Y PVC Control Cable JZ 600-Y PVC  Control Cable PVC Shielded Cable PVC CY Shielded Control Cable Flexible Shielded Connection Cable\u003cstrong data-start=\"257\" data-end=\"289\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable in alignment with DIN VDE 0262, DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eFlexible -15°C to +80°C\u003cbr\u003eFixed -40°C to +80°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 600\/1000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e8000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eFlexible 10x Outer-Ø\u003cbr\u003eFixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: black (RAL 9005)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Resistant to: UV radiation, weathering effects\u003cbr\u003e• Largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• For outdoor use\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• UV-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Weather-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size :\u003c\/b\u003e 19 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 25 G 0.75\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e21.9\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 306.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 729.0\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63258110001521,"sku":"NNC11504","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_afa32979-c31a-49a3-81f7-8c857d95172b.png?v=1772621095"},{"product_id":"18-awg-2c-helukabel-11516-oz-600-y-cy-pvc-control-and-connection-cable","title":"18 AWG 2C Helukabel 11516 OZ-600-Y-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11464_EN_GB_1.pdf?v=1772609466\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e18 AWG 2C Helukabel 11516 OZ-600-Y-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a connection and control cable in machine tools, assembly lines and conveyor belts, production lines, plant construction, heating and air-conditioning technology and in smelters and steel mills. Suitable for flexible applications involving medium mechanical\u003cbr\u003estress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, as well as outdoors (fixed installation). May not be laid directly in soil (suitable for direct burial starting with an outer diameter of 20 mm) or water. Due to its extended nominal voltage range and good UV resistance, this cable is primarily used in Southern Europe, Arabic, Asian and Eastern countries. Due to the high screening density, interference-free transmission of signals or pulses is ensured. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding. \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"153\" data-start=\"124\"\u003e18 AWG 2C OZ 600 Y CY Control Cable OZ 600 Y CY Control Cable PVC Shielded Control Cable Flexible PVC Connection Cable Series 18 AWG 2C Control Cable Shielded PVC Control Cable Flexible PVC Armored Cable OZ 600-Y PVC Control Cable OZ 600-Y PVC \u003cbr\u003e18 AWG 2C Control Cable PVC Shielded Cable PVC CY Shielded Control Cable Flexible Shielded Connection Cable\u003cstrong data-end=\"289\" data-start=\"257\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable in alignment with DIN VDE 0262, DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eFlexible -15°C to +80°C\u003cbr\u003eFixed -40°C to +80°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 600\/1000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e8000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eFlexible 10x Outer-Ø\u003cbr\u003eFixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: black (RAL 9005)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Resistant to: UV radiation, weathering effects\u003cbr\u003e• Largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• For outdoor use\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• UV-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Weather-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size :\u003c\/b\u003e 18 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 2 x 1\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e9.2\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 54.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 146.0\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63258180878705,"sku":"NNC11516","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design-Photoroom_baecf753-6698-47bc-9db3-f711026d37bb.png?v=1772689423"},{"product_id":"18-awg-3c-helukabel-11517-jz-600-y-cy-pvc-control-and-connection-cable","title":"18 AWG 3C Helukabel 11517 JZ-600-Y-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11464_EN_GB_1.pdf?v=1772609466\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e18 AWG 3C Helukabel 11517 JZ-600-Y-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a connection and control cable in machine tools, assembly lines and conveyor belts, production lines, plant construction, heating and air-conditioning technology and in smelters and steel mills. Suitable for flexible applications involving medium mechanical\u003cbr\u003estress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, as well as outdoors (fixed installation). May not be laid directly in soil (suitable for direct burial starting with an outer diameter of 20 mm) or water. Due to its extended nominal voltage range and good UV resistance, this cable is primarily used in Southern Europe, Arabic, Asian and Eastern countries. Due to the high screening density, interference-free transmission of signals or pulses is ensured. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding. \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"153\" data-start=\"124\"\u003e18 AWG 3C JZ 600 Y CY Control Cable JZ 600 Y CY Control Cable PVC Shielded Control Cable Flexible PVC Connection Cable Series 18 AWG 3C Control Cable Shielded PVC Control Cable Flexible PVC Armored Cable 18 AWG 3C JZ 600-Y PVC Control Cable JZ 600-Y PVC  Control Cable PVC Shielded Cable PVC CY Shielded Control Cable Flexible Shielded Connection Cable\u003cstrong data-end=\"289\" data-start=\"257\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable in alignment with DIN VDE 0262, DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eFlexible -15°C to +80°C\u003cbr\u003eFixed -40°C to +80°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 600\/1000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e8000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eFlexible 10x Outer-Ø\u003cbr\u003eFixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: black (RAL 9005)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Resistant to: UV radiation, weathering effects\u003cbr\u003e• Largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• For outdoor use\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• UV-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Weather-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size :\u003c\/b\u003e 18 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 3 G 1\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e9.8\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 64.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 165.0\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63258285113713,"sku":"NNC11517","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_afa32979-c31a-49a3-81f7-8c857d95172b.png?v=1772621095"},{"product_id":"18-awg-4c-helukabel-11518-jz-600-y-cy-pvc-control-and-connection-cable","title":"18 AWG 4C Helukabel 11518 JZ-600-Y-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11464_EN_GB_1.pdf?v=1772609466\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e18 AWG 4C Helukabel 11518 JZ-600-Y-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a connection and control cable in machine tools, assembly lines and conveyor belts, production lines, plant construction, heating and air-conditioning technology and in smelters and steel mills. Suitable for flexible applications involving medium mechanical\u003cbr\u003estress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, as well as outdoors (fixed installation). May not be laid directly in soil (suitable for direct burial starting with an outer diameter of 20 mm) or water. Due to its extended nominal voltage range and good UV resistance, this cable is primarily used in Southern Europe, Arabic, Asian and Eastern countries. Due to the high screening density, interference-free transmission of signals or pulses is ensured. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding. \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"153\" data-start=\"124\"\u003e18 AWG 4C JZ 600 Y CY Control Cable JZ 600 Y CY Control Cable PVC Shielded Control Cable Flexible PVC Connection Cable Series 18 AWG 4C Control Cable Shielded PVC Control Cable Flexible PVC Armored Cable 18 AWG 4C JZ 600-Y PVC Control Cable JZ 600-Y PVC  Control Cable PVC Shielded Cable PVC CY Shielded Control Cable Flexible Shielded Connection Cable\u003cstrong data-end=\"289\" data-start=\"257\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable in alignment with DIN VDE 0262, DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eFlexible -15°C to +80°C\u003cbr\u003eFixed -40°C to +80°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 600\/1000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e8000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eFlexible 10x Outer-Ø\u003cbr\u003eFixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: black (RAL 9005)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Resistant to: UV radiation, weathering effects\u003cbr\u003e• Largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• For outdoor use\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• UV-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Weather-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size :\u003c\/b\u003e 18 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 4 G 1\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e10.4\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 76.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 204.0\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63258288488817,"sku":"NNC11518","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_afa32979-c31a-49a3-81f7-8c857d95172b.png?v=1772621095"},{"product_id":"18-awg-5c-helukabel-11519-jz-600-y-cy-pvc-control-and-connection-cable","title":"18 AWG 5C Helukabel 11519 JZ-600-Y-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11464_EN_GB_1.pdf?v=1772609466\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e18 AWG 5C Helukabel 11519 JZ-600-Y-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a connection and control cable in machine tools, assembly lines and conveyor belts, production lines, plant construction, heating and air-conditioning technology and in smelters and steel mills. Suitable for flexible applications involving medium mechanical\u003cbr\u003estress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, as well as outdoors (fixed installation). May not be laid directly in soil (suitable for direct burial starting with an outer diameter of 20 mm) or water. Due to its extended nominal voltage range and good UV resistance, this cable is primarily used in Southern Europe, Arabic, Asian and Eastern countries. Due to the high screening density, interference-free transmission of signals or pulses is ensured. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding. \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"153\" data-start=\"124\"\u003e18 AWG 5C JZ 600 Y CY Control Cable JZ 600 Y CY Control Cable PVC Shielded Control Cable Flexible PVC Connection Cable Series 18 AWG 5C Control Cable Shielded PVC Control Cable Flexible PVC Armored Cable 18 AWG 5C JZ 600-Y PVC Control Cable JZ 600-Y PVC  Control Cable PVC Shielded Cable PVC CY Shielded Control Cable Flexible Shielded Connection Cable\u003cstrong data-end=\"289\" data-start=\"257\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable in alignment with DIN VDE 0262, DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eFlexible -15°C to +80°C\u003cbr\u003eFixed -40°C to +80°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 600\/1000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e8000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eFlexible 10x Outer-Ø\u003cbr\u003eFixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: black (RAL 9005)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Resistant to: UV radiation, weathering effects\u003cbr\u003e• Largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• For outdoor use\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• UV-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Weather-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size :\u003c\/b\u003e 18 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 5 G 1\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e11.6 \u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 89.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 224.0\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63258293305713,"sku":"NNC11519","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_afa32979-c31a-49a3-81f7-8c857d95172b.png?v=1772621095"},{"product_id":"18-awg-7c-helukabel-11521-jz-600-y-cy-pvc-control-and-connection-cable","title":"18 AWG 7C Helukabel 11521 JZ-600-Y-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11464_EN_GB_1.pdf?v=1772609466\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e18 AWG 7C Helukabel 11521 JZ-600-Y-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a connection and control cable in machine tools, assembly lines and conveyor belts, production lines, plant construction, heating and air-conditioning technology and in smelters and steel mills. Suitable for flexible applications involving medium mechanical\u003cbr\u003estress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, as well as outdoors (fixed installation). May not be laid directly in soil (suitable for direct burial starting with an outer diameter of 20 mm) or water. Due to its extended nominal voltage range and good UV resistance, this cable is primarily used in Southern Europe, Arabic, Asian and Eastern countries. Due to the high screening density, interference-free transmission of signals or pulses is ensured. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding. \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"153\" data-start=\"124\"\u003e18 AWG 7C JZ 600 Y CY Control Cable JZ 600 Y CY Control Cable PVC Shielded Control Cable Flexible PVC Connection Cable Series 18 AWG 7C Control Cable Shielded PVC Control Cable Flexible PVC Armored Cable 18 AWG 7C JZ 600-Y PVC Control Cable JZ 600-Y PVC  Control Cable PVC Shielded Cable PVC CY Shielded Control Cable Flexible Shielded Connection Cable\u003cstrong data-end=\"289\" data-start=\"257\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable in alignment with DIN VDE 0262, DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eFlexible -15°C to +80°C\u003cbr\u003eFixed -40°C to +80°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 600\/1000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e8000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eFlexible 10x Outer-Ø\u003cbr\u003eFixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: black (RAL 9005)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Resistant to: UV radiation, weathering effects\u003cbr\u003e• Largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• For outdoor use\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• UV-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Weather-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size :\u003c\/b\u003e 18 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 7 G 1\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e12.3\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 114.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 252.0\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63258296254833,"sku":"NNC11521","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_afa32979-c31a-49a3-81f7-8c857d95172b.png?v=1772621095"},{"product_id":"18-awg-12c-helukabel-11525-jz-600-y-cy-pvc-control-and-connection-cable","title":"18 AWG 12C Helukabel 11525 JZ-600-Y-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11464_EN_GB_1.pdf?v=1772609466\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e18 AWG 12C Helukabel 11525 JZ-600-Y-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a connection and control cable in machine tools, assembly lines and conveyor belts, production lines, plant construction, heating and air-conditioning technology and in smelters and steel mills. Suitable for flexible applications involving medium mechanical\u003cbr\u003estress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, as well as outdoors (fixed installation). May not be laid directly in soil (suitable for direct burial starting with an outer diameter of 20 mm) or water. Due to its extended nominal voltage range and good UV resistance, this cable is primarily used in Southern Europe, Arabic, Asian and Eastern countries. Due to the high screening density, interference-free transmission of signals or pulses is ensured. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding. \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"153\" data-start=\"124\"\u003e18 AWG 12C JZ 600 Y CY Control Cable JZ 600 Y CY Control Cable PVC Shielded Control Cable Flexible PVC Connection Cable Series 18 AWG 12C Control Cable Shielded PVC Control Cable Flexible PVC Armored Cable 18 AWG 12C JZ 600-Y PVC Control Cable JZ 600-Y PVC  Control Cable PVC Shielded Cable PVC CY Shielded Control Cable Flexible Shielded Connection Cable\u003cstrong data-end=\"289\" data-start=\"257\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable in alignment with DIN VDE 0262, DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eFlexible -15°C to +80°C\u003cbr\u003eFixed -40°C to +80°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 600\/1000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e8000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eFlexible 10x Outer-Ø\u003cbr\u003eFixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: black (RAL 9005)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Resistant to: UV radiation, weathering effects\u003cbr\u003e• Largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• For outdoor use\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• UV-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Weather-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size :\u003c\/b\u003e 18 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 12 G 1\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e16.2\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 186.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 430.0\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63258302284145,"sku":"NNC11525","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_afa32979-c31a-49a3-81f7-8c857d95172b.png?v=1772621095"},{"product_id":"18-awg-18c-helukabel-11528-jz-600-y-cy-pvc-control-and-connection-cable","title":"18 AWG 18C Helukabel 11528 JZ-600-Y-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11464_EN_GB_1.pdf?v=1772609466\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e18 AWG 18C Helukabel 11528 JZ-600-Y-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a connection and control cable in machine tools, assembly lines and conveyor belts, production lines, plant construction, heating and air-conditioning technology and in smelters and steel mills. Suitable for flexible applications involving medium mechanical\u003cbr\u003estress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, as well as outdoors (fixed installation). May not be laid directly in soil (suitable for direct burial starting with an outer diameter of 20 mm) or water. Due to its extended nominal voltage range and good UV resistance, this cable is primarily used in Southern Europe, Arabic, Asian and Eastern countries. Due to the high screening density, interference-free transmission of signals or pulses is ensured. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding. \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"153\" data-start=\"124\"\u003e18 AWG 18C JZ 600 Y CY Control Cable JZ 600 Y CY Control Cable PVC Shielded Control Cable Flexible PVC Connection Cable Series 18 AWG 18C Control Cable Shielded PVC Control Cable Flexible PVC Armored Cable 18 AWG 18C JZ 600-Y PVC Control Cable JZ 600-Y PVC  Control Cable PVC Shielded Cable PVC CY Shielded Control Cable Flexible Shielded Connection Cable\u003cstrong data-end=\"289\" data-start=\"257\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable in alignment with DIN VDE 0262, DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eFlexible -15°C to +80°C\u003cbr\u003eFixed -40°C to +80°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 600\/1000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e8000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eFlexible 10x Outer-Ø\u003cbr\u003eFixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: black (RAL 9005)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Resistant to: UV radiation, weathering effects\u003cbr\u003e• Largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• For outdoor use\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• UV-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Weather-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size :\u003c\/b\u003e 18 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 18 G 1\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e18.9\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 284.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 636.0\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63258307133809,"sku":"NNC11528","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_afa32979-c31a-49a3-81f7-8c857d95172b.png?v=1772621095"},{"product_id":"18-awg-25c-helukabel-11532-jz-600-y-cy-pvc-control-and-connection-cable","title":"18 AWG 25C Helukabel 11532 JZ-600-Y-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11464_EN_GB_1.pdf?v=1772609466\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e18 AWG 25C Helukabel 11532 JZ-600-Y-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a connection and control cable in machine tools, assembly lines and conveyor belts, production lines, plant construction, heating and air-conditioning technology and in smelters and steel mills. Suitable for flexible applications involving medium mechanical\u003cbr\u003estress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, as well as outdoors (fixed installation). May not be laid directly in soil (suitable for direct burial starting with an outer diameter of 20 mm) or water. Due to its extended nominal voltage range and good UV resistance, this cable is primarily used in Southern Europe, Arabic, Asian and Eastern countries. Due to the high screening density, interference-free transmission of signals or pulses is ensured. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding. \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"153\" data-start=\"124\"\u003e18 AWG 25C JZ 600 Y CY Control Cable JZ 600 Y CY Control Cable PVC Shielded Control Cable Flexible PVC Connection Cable Series 18 AWG 25C Control Cable Shielded PVC Control Cable Flexible PVC Armored Cable 18 AWG 25C JZ 600-Y PVC Control Cable JZ 600-Y PVC  Control Cable PVC Shielded Cable PVC CY Shielded Control Cable Flexible Shielded Connection Cable\u003cstrong data-end=\"289\" data-start=\"257\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable in alignment with DIN VDE 0262, DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eFlexible -15°C to +80°C\u003cbr\u003eFixed -40°C to +80°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 600\/1000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e8000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eFlexible 10x Outer-Ø\u003cbr\u003eFixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: black (RAL 9005)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Resistant to: UV radiation, weathering effects\u003cbr\u003e• Largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• For outdoor use\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• UV-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Weather-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size :\u003c\/b\u003e 18 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 25 G 1\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e22.8\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 387.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 837.0\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63258309394801,"sku":"NNC11532","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_afa32979-c31a-49a3-81f7-8c857d95172b.png?v=1772621095"},{"product_id":"16-awg-2c-helukabel-11546-oz-600-y-cy-pvc-control-and-connection-cable","title":"16 AWG 2C Helukabel 11546 OZ-600-Y-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11464_EN_GB_1.pdf?v=1772609466\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e16 AWG 2C Helukabel 11546 OZ-600-Y-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a connection and control cable in machine tools, assembly lines and conveyor belts, production lines, plant construction, heating and air-conditioning technology and in smelters and steel mills. Suitable for flexible applications involving medium mechanical\u003cbr\u003estress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, as well as outdoors (fixed installation). May not be laid directly in soil (suitable for direct burial starting with an outer diameter of 20 mm) or water. Due to its extended nominal voltage range and good UV resistance, this cable is primarily used in Southern Europe, Arabic, Asian and Eastern countries. Due to the high screening density, interference-free transmission of signals or pulses is ensured. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding. \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"153\" data-start=\"124\"\u003e16 AWG 2C OZ 600 Y CY Control Cable OZ 600 Y CY Control Cable PVC Shielded Control Cable Flexible PVC Connection Cable Series 16 AWG 2C Control Cable Shielded PVC Control Cable Flexible PVC Armored Cable 16 AWG 2C OZ 600-Y PVC Control Cable OZ 600-Y PVC  Control Cable PVC Shielded Cable PVC CY Shielded Control Cable Flexible Shielded Connection Cable\u003cstrong data-end=\"289\" data-start=\"257\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable in alignment with DIN VDE 0262, DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eFlexible -15°C to +80°C\u003cbr\u003eFixed -40°C to +80°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 600\/1000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e8000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eFlexible 10x Outer-Ø\u003cbr\u003eFixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: black (RAL 9005)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Resistant to: UV radiation, weathering effects\u003cbr\u003e• Largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• For outdoor use\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• UV-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Weather-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size :\u003c\/b\u003e 16 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 2 x 1.5\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e10.4\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 64.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 175.0\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63258309919089,"sku":"NNC11546","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design-Photoroom_baecf753-6698-47bc-9db3-f711026d37bb.png?v=1772689423"},{"product_id":"16-awg-3c-helukabel-11547-jz-600-y-cy-pvc-control-and-connection-cable","title":"16 AWG 3C Helukabel 11547 JZ-600-Y-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11464_EN_GB_1.pdf?v=1772609466\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e16 AWG 3C Helukabel 11547 JZ-600-Y-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a connection and control cable in machine tools, assembly lines and conveyor belts, production lines, plant construction, heating and air-conditioning technology and in smelters and steel mills. Suitable for flexible applications involving medium mechanical\u003cbr\u003estress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, as well as outdoors (fixed installation). May not be laid directly in soil (suitable for direct burial starting with an outer diameter of 20 mm) or water. Due to its extended nominal voltage range and good UV resistance, this cable is primarily used in Southern Europe, Arabic, Asian and Eastern countries. Due to the high screening density, interference-free transmission of signals or pulses is ensured. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding. \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"153\" data-start=\"124\"\u003e16 AWG 3C JZ 600 Y CY Control Cable JZ 600 Y CY Control Cable PVC Shielded Control Cable Flexible PVC Connection Cable Series 16 AWG 3C Control Cable Shielded PVC Control Cable Flexible PVC Armored Cable 16 AWG 3C JZ 600-Y PVC Control Cable JZ 600-Y PVC  Control Cable PVC Shielded Cable PVC CY Shielded Control Cable Flexible Shielded Connection Cable\u003cstrong data-end=\"289\" data-start=\"257\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable in alignment with DIN VDE 0262, DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eFlexible -15°C to +80°C\u003cbr\u003eFixed -40°C to +80°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 600\/1000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e8000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eFlexible 10x Outer-Ø\u003cbr\u003eFixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: black (RAL 9005)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Resistant to: UV radiation, weathering effects\u003cbr\u003e• Largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• For outdoor use\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• UV-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Weather-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size :\u003c\/b\u003e 16 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 3 G 1.5\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e11.3\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 82.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 213.0\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63258310705521,"sku":"NNC11547","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_9879a4c9-ec32-48d4-bacc-774cd2a74ac4.png?v=1772691247"},{"product_id":"16-awg-4c-helukabel-11548-jz-600-y-cy-pvc-control-and-connection-cable","title":"16 AWG 4C Helukabel 11548 JZ-600-Y-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11464_EN_GB_1.pdf?v=1772609466\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e16 AWG 4C Helukabel 11548 JZ-600-Y-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a connection and control cable in machine tools, assembly lines and conveyor belts, production lines, plant construction, heating and air-conditioning technology and in smelters and steel mills. Suitable for flexible applications involving medium mechanical\u003cbr\u003estress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, as well as outdoors (fixed installation). May not be laid directly in soil (suitable for direct burial starting with an outer diameter of 20 mm) or water. Due to its extended nominal voltage range and good UV resistance, this cable is primarily used in Southern Europe, Arabic, Asian and Eastern countries. Due to the high screening density, interference-free transmission of signals or pulses is ensured. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding. \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"153\" data-start=\"124\"\u003e16 AWG 4C JZ 600 Y CY Control Cable JZ 600 Y CY Control Cable PVC Shielded Control Cable Flexible PVC Connection Cable Series 16 AWG 4C Control Cable Shielded PVC Control Cable Flexible PVC Armored Cable 16 AWG 4C JZ 600-Y PVC Control Cable JZ 600-Y PVC  Control Cable PVC Shielded Cable PVC CY Shielded Control Cable Flexible Shielded Connection Cable\u003cstrong data-end=\"289\" data-start=\"257\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable in alignment with DIN VDE 0262, DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eFlexible -15°C to +80°C\u003cbr\u003eFixed -40°C to +80°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 600\/1000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e8000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eFlexible 10x Outer-Ø\u003cbr\u003eFixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: black (RAL 9005)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Resistant to: UV radiation, weathering effects\u003cbr\u003e• Largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• For outdoor use\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• UV-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Weather-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size :\u003c\/b\u003e 16 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 4 G 1.5\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e12.0\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 99.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 247.0\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63258328695153,"sku":"NNC11548","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_9879a4c9-ec32-48d4-bacc-774cd2a74ac4.png?v=1772691247"},{"product_id":"16-awg-5c-helukabel-11549-jz-600-y-cy-pvc-control-and-connection-cable","title":"16 AWG 5C Helukabel 11549 JZ-600-Y-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11464_EN_GB_1.pdf?v=1772609466\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e16 AWG 5C Helukabel 11549 JZ-600-Y-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a connection and control cable in machine tools, assembly lines and conveyor belts, production lines, plant construction, heating and air-conditioning technology and in smelters and steel mills. Suitable for flexible applications involving medium mechanical\u003cbr\u003estress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, as well as outdoors (fixed installation). May not be laid directly in soil (suitable for direct burial starting with an outer diameter of 20 mm) or water. Due to its extended nominal voltage range and good UV resistance, this cable is primarily used in Southern Europe, Arabic, Asian and Eastern countries. Due to the high screening density, interference-free transmission of signals or pulses is ensured. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding. \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"153\" data-start=\"124\"\u003e16 AWG 5C JZ 600 Y CY Control Cable JZ 600 Y CY Control Cable PVC Shielded Control Cable Flexible PVC Connection Cable Series 16 AWG 5C Control Cable Shielded PVC Control Cable Flexible PVC Armored Cable 16 AWG 5C JZ 600-Y PVC Control Cable JZ 600-Y PVC  Control Cable PVC Shielded Cable PVC CY Shielded Control Cable Flexible Shielded Connection Cable\u003cstrong data-end=\"289\" data-start=\"257\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable in alignment with DIN VDE 0262, DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eFlexible -15°C to +80°C\u003cbr\u003eFixed -40°C to +80°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 600\/1000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e8000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eFlexible 10x Outer-Ø\u003cbr\u003eFixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: black (RAL 9005)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Resistant to: UV radiation, weathering effects\u003cbr\u003e• Largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• For outdoor use\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• UV-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Weather-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size :\u003c\/b\u003e 16 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 5 G 1.5\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e13.1\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 123.0 \u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 300.0\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63258372473201,"sku":"NNC11549","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_9879a4c9-ec32-48d4-bacc-774cd2a74ac4.png?v=1772691247"},{"product_id":"16-awg-7c-helukabel-11551-jz-600-y-cy-pvc-control-and-connection-cable","title":"16 AWG 7C Helukabel 11551 JZ-600-Y-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11464_EN_GB_1.pdf?v=1772609466\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e16 AWG 7C Helukabel 11551 JZ-600-Y-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a connection and control cable in machine tools, assembly lines and conveyor belts, production lines, plant construction, heating and air-conditioning technology and in smelters and steel mills. Suitable for flexible applications involving medium mechanical\u003cbr\u003estress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, as well as outdoors (fixed installation). May not be laid directly in soil (suitable for direct burial starting with an outer diameter of 20 mm) or water. Due to its extended nominal voltage range and good UV resistance, this cable is primarily used in Southern Europe, Arabic, Asian and Eastern countries. Due to the high screening density, interference-free transmission of signals or pulses is ensured. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding. \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"153\" data-start=\"124\"\u003e16 AWG 7C JZ 600 Y CY Control Cable JZ 600 Y CY Control Cable PVC Shielded Control Cable Flexible PVC Connection Cable Series 16 AWG 7C Control Cable Shielded PVC Control Cable Flexible PVC Armored Cable 16 AWG 7C JZ 600-Y PVC Control Cable JZ 600-Y PVC  Control Cable PVC Shielded Cable PVC CY Shielded Control Cable Flexible Shielded Connection Cable\u003cstrong data-end=\"289\" data-start=\"257\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable in alignment with DIN VDE 0262, DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eFlexible -15°C to +80°C\u003cbr\u003eFixed -40°C to +80°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 600\/1000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e8000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eFlexible 10x Outer-Ø\u003cbr\u003eFixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: black (RAL 9005)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Resistant to: UV radiation, weathering effects\u003cbr\u003e• Largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• For outdoor use\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• UV-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Weather-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size :\u003c\/b\u003e 16 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 7 G 1.5\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e14.6\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 148.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 364.0\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63258374078833,"sku":"NNC11551","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_9879a4c9-ec32-48d4-bacc-774cd2a74ac4.png?v=1772691247"},{"product_id":"16-awg-12c-helukabel-11556-jz-600-y-cy-pvc-control-and-connection-cable","title":"16 AWG 12C Helukabel 11556 JZ-600-Y-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11464_EN_GB_1.pdf?v=1772609466\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e16 AWG 12C Helukabel 11556 JZ-600-Y-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a connection and control cable in machine tools, assembly lines and conveyor belts, production lines, plant construction, heating and air-conditioning technology and in smelters and steel mills. Suitable for flexible applications involving medium mechanical\u003cbr\u003estress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, as well as outdoors (fixed installation). May not be laid directly in soil (suitable for direct burial starting with an outer diameter of 20 mm) or water. Due to its extended nominal voltage range and good UV resistance, this cable is primarily used in Southern Europe, Arabic, Asian and Eastern countries. Due to the high screening density, interference-free transmission of signals or pulses is ensured. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding. \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"153\" data-start=\"124\"\u003e16 AWG 12C JZ 600 Y CY Control Cable JZ 600 Y CY Control Cable PVC Shielded Control Cable Flexible PVC Connection Cable Series 16 AWG 12C Control Cable Shielded PVC Control Cable Flexible PVC Armored Cable 16 AWG 12C JZ 600-Y PVC Control Cable JZ 600-Y PVC  Control Cable PVC Shielded Cable PVC CY Shielded Control Cable Flexible Shielded Connection Cable\u003cstrong data-end=\"289\" data-start=\"257\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable in alignment with DIN VDE 0262, DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eFlexible -15°C to +80°C\u003cbr\u003eFixed -40°C to +80°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 600\/1000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e8000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eFlexible 10x Outer-Ø\u003cbr\u003eFixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: black (RAL 9005)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Resistant to: UV radiation, weathering effects\u003cbr\u003e• Largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• For outdoor use\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• UV-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Weather-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size :\u003c\/b\u003e 16 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 12 G 1.5\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e18.7\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 274.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 668.0\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63258374373745,"sku":"NNC11556","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_9879a4c9-ec32-48d4-bacc-774cd2a74ac4.png?v=1772691247"},{"product_id":"16-awg-18c-helukabel-11559-jz-600-y-cy-pvc-control-and-connection-cable","title":"16 AWG 18C Helukabel 11559 JZ-600-Y-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11464_EN_GB_1.pdf?v=1772609466\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e16 AWG 18C Helukabel 11559 JZ-600-Y-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a connection and control cable in machine tools, assembly lines and conveyor belts, production lines, plant construction, heating and air-conditioning technology and in smelters and steel mills. Suitable for flexible applications involving medium mechanical\u003cbr\u003estress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, as well as outdoors (fixed installation). May not be laid directly in soil (suitable for direct burial starting with an outer diameter of 20 mm) or water. Due to its extended nominal voltage range and good UV resistance, this cable is primarily used in Southern Europe, Arabic, Asian and Eastern countries. Due to the high screening density, interference-free transmission of signals or pulses is ensured. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding. \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"153\" data-start=\"124\"\u003e16 AWG 18C JZ 600 Y CY Control Cable JZ 600 Y CY Control Cable PVC Shielded Control Cable Flexible PVC Connection Cable Series 16 AWG 18C Control Cable Shielded PVC Control Cable Flexible PVC Armored Cable 16 AWG 18C JZ 600-Y PVC Control Cable JZ 600-Y PVC  Control Cable PVC Shielded Cable PVC CY Shielded Control Cable Flexible Shielded Connection Cable\u003cstrong data-end=\"289\" data-start=\"257\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable in alignment with DIN VDE 0262, DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eFlexible -15°C to +80°C\u003cbr\u003eFixed -40°C to +80°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 600\/1000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e8000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eFlexible 10x Outer-Ø\u003cbr\u003eFixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: black (RAL 9005)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Resistant to: UV radiation, weathering effects\u003cbr\u003e• Largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• For outdoor use\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• UV-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Weather-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size :\u003c\/b\u003e 16 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 18 G 1.5\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e22.8\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 386.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 844.0\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63258375029105,"sku":"NNC11559","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_9879a4c9-ec32-48d4-bacc-774cd2a74ac4.png?v=1772691247"},{"product_id":"16-awg-25c-helukabel-11563-jz-600-y-cy-pvc-control-and-connection-cable","title":"16 AWG 25C Helukabel 11563 JZ-600-Y-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11464_EN_GB_1.pdf?v=1772609466\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e16 AWG 25C Helukabel 11563 JZ-600-Y-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a connection and control cable in machine tools, assembly lines and conveyor belts, production lines, plant construction, heating and air-conditioning technology and in smelters and steel mills. Suitable for flexible applications involving medium mechanical\u003cbr\u003estress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, as well as outdoors (fixed installation). May not be laid directly in soil (suitable for direct burial starting with an outer diameter of 20 mm) or water. Due to its extended nominal voltage range and good UV resistance, this cable is primarily used in Southern Europe, Arabic, Asian and Eastern countries. Due to the high screening density, interference-free transmission of signals or pulses is ensured. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding. \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"153\" data-start=\"124\"\u003e16 AWG 25C JZ 600 Y CY Control Cable JZ 600 Y CY Control Cable PVC Shielded Control Cable Flexible PVC Connection Cable Series 16 AWG 25C Control Cable Shielded PVC Control Cable Flexible PVC Armored Cable 16 AWG 25C JZ 600-Y PVC Control Cable JZ 600-Y PVC  Control Cable PVC Shielded Cable PVC CY Shielded Control Cable Flexible Shielded Connection Cable\u003cstrong data-end=\"289\" data-start=\"257\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable in alignment with DIN VDE 0262, DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eFlexible -15°C to +80°C\u003cbr\u003eFixed -40°C to +80°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 600\/1000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e8000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eFlexible 10x Outer-Ø\u003cbr\u003eFixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: black (RAL 9005)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Resistant to: UV radiation, weathering effects\u003cbr\u003e• Largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• For outdoor use\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• UV-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Weather-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size :\u003c\/b\u003e 16 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 25 G 1.5\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e26.2\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 531.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 1356.0\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63258414317937,"sku":"NNC11563","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_9879a4c9-ec32-48d4-bacc-774cd2a74ac4.png?v=1772691247"},{"product_id":"14-awg-2c-helukabel-11574oz-600-y-cy-pvc-control-and-connection-cable","title":"14 AWG 2C Helukabel 11574OZ-600-Y-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11464_EN_GB_1.pdf?v=1772609466\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 2C Helukabel 11574OZ-600-Y-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a connection and control cable in machine tools, assembly lines and conveyor belts, production lines, plant construction, heating and air-conditioning technology and in smelters and steel mills. Suitable for flexible applications involving medium mechanical\u003cbr\u003estress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, as well as outdoors (fixed installation). May not be laid directly in soil (suitable for direct burial starting with an outer diameter of 20 mm) or water. Due to its extended nominal voltage range and good UV resistance, this cable is primarily used in Southern Europe, Arabic, Asian and Eastern countries. Due to the high screening density, interference-free transmission of signals or pulses is ensured. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding. \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"153\" data-start=\"124\"\u003e14 AWG 2C OZ 600 Y CY Control Cable OZ 600 Y CY Control Cable PVC Shielded Control Cable Flexible PVC Connection Cable Series 14 AWG 2C Control Cable Shielded PVC Control Cable Flexible PVC Armored Cable 14 AWG 2C OZ 600-Y PVC Control Cable OZ 600-Y PVC  Control Cable PVC Shielded Cable PVC CY Shielded Control Cable Flexible Shielded Connection Cable\u003cstrong data-end=\"289\" data-start=\"257\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable in alignment with DIN VDE 0262, DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eFlexible -15°C to +80°C\u003cbr\u003eFixed -40°C to +80°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 600\/1000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e8000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eFlexible 10x Outer-Ø\u003cbr\u003eFixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: black (RAL 9005)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Resistant to: UV radiation, weathering effects\u003cbr\u003e• Largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• For outdoor use\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• UV-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Weather-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size :\u003c\/b\u003e 14 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 2 x 2.5\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e12.0\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 110.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 241.0\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63258471006577,"sku":"NNC11574","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design-Photoroom_baecf753-6698-47bc-9db3-f711026d37bb.png?v=1772689423"},{"product_id":"14-awg-3c-helukabel-11575-jz-600-y-cy-pvc-control-and-connection-cable","title":"14 AWG 3C Helukabel 11575 JZ-600-Y-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11464_EN_GB_1.pdf?v=1772609466\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 3C Helukabel 11575 JZ-600-Y-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a connection and control cable in machine tools, assembly lines and conveyor belts, production lines, plant construction, heating and air-conditioning technology and in smelters and steel mills. Suitable for flexible applications involving medium mechanical\u003cbr\u003estress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, as well as outdoors (fixed installation). May not be laid directly in soil (suitable for direct burial starting with an outer diameter of 20 mm) or water. Due to its extended nominal voltage range and good UV resistance, this cable is primarily used in Southern Europe, Arabic, Asian and Eastern countries. Due to the high screening density, interference-free transmission of signals or pulses is ensured. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding. \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"153\" data-start=\"124\"\u003e14 AWG 3C JZ 600 Y CY Control Cable JZ 600 Y CY Control Cable PVC Shielded Control Cable Flexible PVC Connection Cable Series 14 AWG 3C Control Cable Shielded PVC Control Cable Flexible PVC Armored Cable 14 AWG 3C JZ 600-Y PVC Control Cable JZ 600-Y PVC  Control Cable PVC Shielded Cable PVC CY Shielded Control Cable Flexible Shielded Connection Cable\u003cstrong data-end=\"289\" data-start=\"257\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable in alignment with DIN VDE 0262, DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eFlexible -15°C to +80°C\u003cbr\u003eFixed -40°C to +80°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 600\/1000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e8000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eFlexible 10x Outer-Ø\u003cbr\u003eFixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: black (RAL 9005)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Resistant to: UV radiation, weathering effects\u003cbr\u003e• Largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• For outdoor use\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• UV-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Weather-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size :\u003c\/b\u003e 14 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 3 G 2.5\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e12.6\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 148.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 266.0\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63258471694705,"sku":"NNC11575","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_9879a4c9-ec32-48d4-bacc-774cd2a74ac4.png?v=1772691247"},{"product_id":"14-awg-4c-helukabel-11576-jz-600-y-cy-pvc-control-and-connection-cable","title":"14 AWG 4C Helukabel 11576 JZ-600-Y-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11464_EN_GB_1.pdf?v=1772609466\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 4C Helukabel 11576 JZ-600-Y-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a connection and control cable in machine tools, assembly lines and conveyor belts, production lines, plant construction, heating and air-conditioning technology and in smelters and steel mills. Suitable for flexible applications involving medium mechanical\u003cbr\u003estress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, as well as outdoors (fixed installation). May not be laid directly in soil (suitable for direct burial starting with an outer diameter of 20 mm) or water. Due to its extended nominal voltage range and good UV resistance, this cable is primarily used in Southern Europe, Arabic, Asian and Eastern countries. Due to the high screening density, interference-free transmission of signals or pulses is ensured. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding. \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"153\" data-start=\"124\"\u003e14 AWG 4C JZ 600 Y CY Control Cable JZ 600 Y CY Control Cable PVC Shielded Control Cable Flexible PVC Connection Cable Series 14 AWG 4C Control Cable Shielded PVC Control Cable Flexible PVC Armored Cable 14 AWG 4C JZ 600-Y PVC Control Cable JZ 600-Y PVC  Control Cable PVC Shielded Cable PVC CY Shielded Control Cable Flexible Shielded Connection Cable\u003cstrong data-end=\"289\" data-start=\"257\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable in alignment with DIN VDE 0262, DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eFlexible -15°C to +80°C\u003cbr\u003eFixed -40°C to +80°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 600\/1000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e8000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eFlexible 10x Outer-Ø\u003cbr\u003eFixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: black (RAL 9005)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Resistant to: UV radiation, weathering effects\u003cbr\u003e• Largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• For outdoor use\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• UV-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Weather-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size :\u003c\/b\u003e 14 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 4 G 2.5\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e13.9 \u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 169.0 \u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 351.0\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63258472153457,"sku":"NNC11576","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_9879a4c9-ec32-48d4-bacc-774cd2a74ac4.png?v=1772691247"},{"product_id":"14-awg-5c-helukabel-11577-jz-600-y-cy-pvc-control-and-connection-cable","title":"14 AWG 5C Helukabel 11577 JZ-600-Y-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11464_EN_GB_1.pdf?v=1772609466\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 5C Helukabel 11577 JZ-600-Y-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a connection and control cable in machine tools, assembly lines and conveyor belts, production lines, plant construction, heating and air-conditioning technology and in smelters and steel mills. Suitable for flexible applications involving medium mechanical\u003cbr\u003estress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, as well as outdoors (fixed installation). May not be laid directly in soil (suitable for direct burial starting with an outer diameter of 20 mm) or water. Due to its extended nominal voltage range and good UV resistance, this cable is primarily used in Southern Europe, Arabic, Asian and Eastern countries. Due to the high screening density, interference-free transmission of signals or pulses is ensured. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding. \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"153\" data-start=\"124\"\u003e14 AWG 5C JZ 600 Y CY Control Cable JZ 600 Y CY Control Cable PVC Shielded Control Cable Flexible PVC Connection Cable Series 14 AWG 5C Control Cable Shielded PVC Control Cable Flexible PVC Armored Cable 14 AWG 5C JZ 600-Y PVC Control Cable JZ 600-Y PVC  Control Cable PVC Shielded Cable PVC CY Shielded Control Cable Flexible Shielded Connection Cable\u003cstrong data-end=\"289\" data-start=\"257\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable in alignment with DIN VDE 0262, DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eFlexible -15°C to +80°C\u003cbr\u003eFixed -40°C to +80°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 600\/1000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e8000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eFlexible 10x Outer-Ø\u003cbr\u003eFixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: black (RAL 9005)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Resistant to: UV radiation, weathering effects\u003cbr\u003e• Largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• For outdoor use\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• UV-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Weather-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size :\u003c\/b\u003e 14 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 5 G 2.5\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e15.4\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 220.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 434.0\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63258473169265,"sku":"NNC11577","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_9879a4c9-ec32-48d4-bacc-774cd2a74ac4.png?v=1772691247"},{"product_id":"14-awg-7c-helukabel-11578-jz-600-y-cy-pvc-control-and-connection-cable","title":"14 AWG 7C Helukabel 11578 JZ-600-Y-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11464_EN_GB_1.pdf?v=1772609466\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 7C Helukabel 11578 JZ-600-Y-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a connection and control cable in machine tools, assembly lines and conveyor belts, production lines, plant construction, heating and air-conditioning technology and in smelters and steel mills. Suitable for flexible applications involving medium mechanical\u003cbr\u003estress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, as well as outdoors (fixed installation). May not be laid directly in soil (suitable for direct burial starting with an outer diameter of 20 mm) or water. Due to its extended nominal voltage range and good UV resistance, this cable is primarily used in Southern Europe, Arabic, Asian and Eastern countries. Due to the high screening density, interference-free transmission of signals or pulses is ensured. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding. \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"153\" data-start=\"124\"\u003e14 AWG 7C JZ 600 Y CY Control Cable JZ 600 Y CY Control Cable PVC Shielded Control Cable Flexible PVC Connection Cable Series 14 AWG 7C Control Cable Shielded PVC Control Cable Flexible PVC Armored Cable 14 AWG 7C JZ 600-Y PVC Control Cable JZ 600-Y PVC  Control Cable PVC Shielded Cable PVC CY Shielded Control Cable Flexible Shielded Connection Cable\u003cstrong data-end=\"289\" data-start=\"257\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable in alignment with DIN VDE 0262, DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eFlexible -15°C to +80°C\u003cbr\u003eFixed -40°C to +80°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 600\/1000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e8000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eFlexible 10x Outer-Ø\u003cbr\u003eFixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: black (RAL 9005)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Resistant to: UV radiation, weathering effects\u003cbr\u003e• Largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• For outdoor use\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• UV-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Weather-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size :\u003c\/b\u003e 14 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 7 G 2.5\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e16.6\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 284.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 517.0\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63258554335601,"sku":"NNC11578","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_9879a4c9-ec32-48d4-bacc-774cd2a74ac4.png?v=1772691247"},{"product_id":"14-awg-12c-helukabel-11580-jz-600-y-cy-pvc-control-and-connection-cable","title":"14 AWG 12C Helukabel 11580 JZ-600-Y-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11464_EN_GB_1.pdf?v=1772609466\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 12C Helukabel 11580 JZ-600-Y-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a connection and control cable in machine tools, assembly lines and conveyor belts, production lines, plant construction, heating and air-conditioning technology and in smelters and steel mills. Suitable for flexible applications involving medium mechanical\u003cbr\u003estress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, as well as outdoors (fixed installation). May not be laid directly in soil (suitable for direct burial starting with an outer diameter of 20 mm) or water. Due to its extended nominal voltage range and good UV resistance, this cable is primarily used in Southern Europe, Arabic, Asian and Eastern countries. Due to the high screening density, interference-free transmission of signals or pulses is ensured. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding. \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"153\" data-start=\"124\"\u003e14 AWG 12C JZ 600 Y CY Control Cable JZ 600 Y CY Control Cable PVC Shielded Control Cable Flexible PVC Connection Cable Series 14 AWG 12C Control Cable Shielded PVC Control Cable Flexible PVC Armored Cable 14 AWG 12C JZ 600-Y PVC Control Cable JZ 600-Y PVC  Control Cable PVC Shielded Cable PVC CY Shielded Control Cable Flexible Shielded Connection Cable\u003cstrong data-end=\"289\" data-start=\"257\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable in alignment with DIN VDE 0262, DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eFlexible -15°C to +80°C\u003cbr\u003eFixed -40°C to +80°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 600\/1000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e8000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eFlexible 10x Outer-Ø\u003cbr\u003eFixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: black (RAL 9005)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Resistant to: UV radiation, weathering effects\u003cbr\u003e• Largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• For outdoor use\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• UV-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Weather-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size :\u003c\/b\u003e 14 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 12 G 2.5\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e22.8\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 470.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 862.0\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63260551250289,"sku":"NNC11580","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_9879a4c9-ec32-48d4-bacc-774cd2a74ac4.png?v=1772691247"},{"product_id":"14-awg-18c-helukabel-11582-jz-600-y-cy-pvc-control-and-connection-cable","title":"14 AWG 18C Helukabel 11582 JZ-600-Y-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11464_EN_GB_1.pdf?v=1772609466\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 18C Helukabel 11582 JZ-600-Y-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a connection and control cable in machine tools, assembly lines and conveyor belts, production lines, plant construction, heating and air-conditioning technology and in smelters and steel mills. Suitable for flexible applications involving medium mechanical\u003cbr\u003estress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, as well as outdoors (fixed installation). May not be laid directly in soil (suitable for direct burial starting with an outer diameter of 20 mm) or water. Due to its extended nominal voltage range and good UV resistance, this cable is primarily used in Southern Europe, Arabic, Asian and Eastern countries. Due to the high screening density, interference-free transmission of signals or pulses is ensured. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding. \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"153\" data-start=\"124\"\u003e14 AWG 18C JZ 600 Y CY Control Cable JZ 600 Y CY Control Cable PVC Shielded Control Cable Flexible PVC Connection Cable Series 14 AWG 18C Control Cable Shielded PVC Control Cable Flexible PVC Armored Cable 14 AWG 18C JZ 600-Y PVC Control Cable JZ 600-Y PVC  Control Cable PVC Shielded Cable PVC CY Shielded Control Cable Flexible Shielded Connection Cable\u003cstrong data-end=\"289\" data-start=\"257\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable in alignment with DIN VDE 0262, DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eFlexible -15°C to +80°C\u003cbr\u003eFixed -40°C to +80°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 600\/1000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e8000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eFlexible 10x Outer-Ø\u003cbr\u003eFixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: black (RAL 9005)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Resistant to: UV radiation, weathering effects\u003cbr\u003e• Largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• For outdoor use\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• UV-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Weather-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size :\u003c\/b\u003e 14 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 18 G 2.5\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e26.2\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 572.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 1236.0\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63262748377457,"sku":"NNC11582","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_9879a4c9-ec32-48d4-bacc-774cd2a74ac4.png?v=1772691247"},{"product_id":"14-awg-25c-helukabel-11584-jz-600-y-cy-pvc-control-and-connection-cable","title":"14 AWG 25C Helukabel 11584 JZ-600-Y-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11464_EN_GB_1.pdf?v=1772609466\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e14 AWG 25C Helukabel 11584 JZ-600-Y-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a connection and control cable in machine tools, assembly lines and conveyor belts, production lines, plant construction, heating and air-conditioning technology and in smelters and steel mills. Suitable for flexible applications involving medium mechanical\u003cbr\u003estress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, as well as outdoors (fixed installation). May not be laid directly in soil (suitable for direct burial starting with an outer diameter of 20 mm) or water. Due to its extended nominal voltage range and good UV resistance, this cable is primarily used in Southern Europe, Arabic, Asian and Eastern countries. Due to the high screening density, interference-free transmission of signals or pulses is ensured. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding. \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"153\" data-start=\"124\"\u003e14 AWG 25C JZ 600 Y CY Control Cable JZ 600 Y CY Control Cable PVC Shielded Control Cable Flexible PVC Connection Cable Series 14 AWG 25C Control Cable Shielded PVC Control Cable Flexible PVC Armored Cable 14 AWG 25C JZ 600-Y PVC Control Cable JZ 600-Y PVC  Control Cable PVC Shielded Cable PVC CY Shielded Control Cable Flexible Shielded Connection Cable\u003cstrong data-end=\"289\" data-start=\"257\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable in alignment with DIN VDE 0262, DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eFlexible -15°C to +80°C\u003cbr\u003eFixed -40°C to +80°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 600\/1000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e8000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eFlexible 10x Outer-Ø\u003cbr\u003eFixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: black (RAL 9005)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Resistant to: UV radiation, weathering effects\u003cbr\u003e• Largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• For outdoor use\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• UV-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Weather-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size :\u003c\/b\u003e 14 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 25 G 2.5\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e30.6\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 740.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 1659.0\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63262748475761,"sku":"NNC11584","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_9879a4c9-ec32-48d4-bacc-774cd2a74ac4.png?v=1772691247"},{"product_id":"12-awg-2c-helukabel-11590-oz-600-y-cy-pvc-control-and-connection-cable","title":"12 AWG 2C Helukabel 11590 OZ-600-Y-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11464_EN_GB_1.pdf?v=1772609466\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 2C Helukabel 11590 OZ-600-Y-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a connection and control cable in machine tools, assembly lines and conveyor belts, production lines, plant construction, heating and air-conditioning technology and in smelters and steel mills. Suitable for flexible applications involving medium mechanical\u003cbr\u003estress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, as well as outdoors (fixed installation). May not be laid directly in soil (suitable for direct burial starting with an outer diameter of 20 mm) or water. Due to its extended nominal voltage range and good UV resistance, this cable is primarily used in Southern Europe, Arabic, Asian and Eastern countries. Due to the high screening density, interference-free transmission of signals or pulses is ensured. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding. \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"153\" data-start=\"124\"\u003e12 AWG 2C OZ 600 Y CY Control Cable OZ 600 Y CY Control Cable PVC Shielded Control Cable Flexible PVC Connection Cable Series 12 AWG 2C Control Cable Shielded PVC Control Cable Flexible PVC Armored Cable 12 AWG 2C OZ 600-Y PVC Control Cable OZ 600-Y PVC  Control Cable PVC Shielded Cable PVC CY Shielded Control Cable Flexible Shielded Connection Cable\u003cstrong data-end=\"289\" data-start=\"257\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable in alignment with DIN VDE 0262, DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eFlexible -15°C to +80°C\u003cbr\u003eFixed -40°C to +80°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 600\/1000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e8000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eFlexible 10x Outer-Ø\u003cbr\u003eFixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: black (RAL 9005)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Resistant to: UV radiation, weathering effects\u003cbr\u003e• Largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• For outdoor use\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• UV-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Weather-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size :\u003c\/b\u003e 12 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 2 x 4\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e13.4\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 124.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 306.0\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63262751097201,"sku":"NNC11590","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design-Photoroom_baecf753-6698-47bc-9db3-f711026d37bb.png?v=1772689423"},{"product_id":"12-awg-3c-helukabel-11591-jz-600-y-cy-pvc-control-and-connection-cable-1","title":"12 AWG 3C Helukabel 11591 JZ-600-Y-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11464_EN_GB_1.pdf?v=1772609466\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 3C Helukabel 11591 JZ-600-Y-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a connection and control cable in machine tools, assembly lines and conveyor belts, production lines, plant construction, heating and air-conditioning technology and in smelters and steel mills. Suitable for flexible applications involving medium mechanical\u003cbr\u003estress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, as well as outdoors (fixed installation). May not be laid directly in soil (suitable for direct burial starting with an outer diameter of 20 mm) or water. Due to its extended nominal voltage range and good UV resistance, this cable is primarily used in Southern Europe, Arabic, Asian and Eastern countries. Due to the high screening density, interference-free transmission of signals or pulses is ensured. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding. \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"153\" data-start=\"124\"\u003e12 AWG 3C JZ 600 Y CY Control Cable JZ 600 Y CY Control Cable PVC Shielded Control Cable Flexible PVC Connection Cable Series 12 AWG 3C Control Cable Shielded PVC Control Cable Flexible PVC Armored Cable 12 AWG 3C JZ 600-Y PVC Control Cable JZ 600-Y PVC  Control Cable PVC Shielded Cable PVC CY Shielded Control Cable Flexible Shielded Connection Cable\u003cstrong data-end=\"289\" data-start=\"257\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable in alignment with DIN VDE 0262, DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eFlexible -15°C to +80°C\u003cbr\u003eFixed -40°C to +80°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 600\/1000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e8000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eFlexible 10x Outer-Ø\u003cbr\u003eFixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: black (RAL 9005)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Resistant to: UV radiation, weathering effects\u003cbr\u003e• Largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• For outdoor use\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• UV-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Weather-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size :\u003c\/b\u003e 12 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 3 G 4\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e14.7\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 178.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 444.0\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63262752538993,"sku":"NNC11591","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_9879a4c9-ec32-48d4-bacc-774cd2a74ac4.png?v=1772691247"},{"product_id":"12-awg-4c-helukabel-11592-jz-600-y-cy-pvc-control-and-connection-cable","title":"12 AWG 4C Helukabel 11592 JZ-600-Y-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11464_EN_GB_1.pdf?v=1772609466\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 4C Helukabel 11592 JZ-600-Y-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a connection and control cable in machine tools, assembly lines and conveyor belts, production lines, plant construction, heating and air-conditioning technology and in smelters and steel mills. Suitable for flexible applications involving medium mechanical\u003cbr\u003estress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, as well as outdoors (fixed installation). May not be laid directly in soil (suitable for direct burial starting with an outer diameter of 20 mm) or water. Due to its extended nominal voltage range and good UV resistance, this cable is primarily used in Southern Europe, Arabic, Asian and Eastern countries. Due to the high screening density, interference-free transmission of signals or pulses is ensured. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding. \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"153\" data-start=\"124\"\u003e12 AWG 4C JZ 600 Y CY Control Cable JZ 600 Y CY Control Cable PVC Shielded Control Cable Flexible PVC Connection Cable Series 12 AWG 4C Control Cable Shielded PVC Control Cable Flexible PVC Armored Cable 12 AWG 4C JZ 600-Y PVC Control Cable JZ 600-Y PVC  Control Cable PVC Shielded Cable PVC CY Shielded Control Cable Flexible Shielded Connection Cable\u003cstrong data-end=\"289\" data-start=\"257\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable in alignment with DIN VDE 0262, DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eFlexible -15°C to +80°C\u003cbr\u003eFixed -40°C to +80°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 600\/1000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e8000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eFlexible 10x Outer-Ø\u003cbr\u003eFixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: black (RAL 9005)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Resistant to: UV radiation, weathering effects\u003cbr\u003e• Largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• For outdoor use\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• UV-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Weather-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size :\u003c\/b\u003e 12 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 4 G 4\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e15.9\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 234.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 489.0\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63262753030513,"sku":"NNC11592","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_9879a4c9-ec32-48d4-bacc-774cd2a74ac4.png?v=1772691247"},{"product_id":"12-awg-5c-helukabel-11593-jz-600-y-cy-pvc-control-and-connection-cable","title":"12 AWG 5C Helukabel 11593 JZ-600-Y-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11464_EN_GB_1.pdf?v=1772609466\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 5C Helukabel 11593 JZ-600-Y-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a connection and control cable in machine tools, assembly lines and conveyor belts, production lines, plant construction, heating and air-conditioning technology and in smelters and steel mills. Suitable for flexible applications involving medium mechanical\u003cbr\u003estress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, as well as outdoors (fixed installation). May not be laid directly in soil (suitable for direct burial starting with an outer diameter of 20 mm) or water. Due to its extended nominal voltage range and good UV resistance, this cable is primarily used in Southern Europe, Arabic, Asian and Eastern countries. Due to the high screening density, interference-free transmission of signals or pulses is ensured. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding. \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"153\" data-start=\"124\"\u003e12 AWG 5C JZ 600 Y CY Control Cable JZ 600 Y CY Control Cable PVC Shielded Control Cable Flexible PVC Connection Cable Series 12 AWG 5C Control Cable Shielded PVC Control Cable Flexible PVC Armored Cable 12 AWG 5C JZ 600-Y PVC Control Cable JZ 600-Y PVC  Control Cable PVC Shielded Cable PVC CY Shielded Control Cable Flexible Shielded Connection Cable\u003cstrong data-end=\"289\" data-start=\"257\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable in alignment with DIN VDE 0262, DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eFlexible -15°C to +80°C\u003cbr\u003eFixed -40°C to +80°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 600\/1000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e8000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eFlexible 10x Outer-Ø\u003cbr\u003eFixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: black (RAL 9005)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Resistant to: UV radiation, weathering effects\u003cbr\u003e• Largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• For outdoor use\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• UV-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Weather-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size :\u003c\/b\u003e 12 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 5 G 4\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e17.6\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 284.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 623.0\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63262754013553,"sku":"NNC11593","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_9879a4c9-ec32-48d4-bacc-774cd2a74ac4.png?v=1772691247"},{"product_id":"12-awg-7c-helukabel-11594-jz-600-y-cy-pvc-control-and-connection-cable","title":"12 AWG 7C Helukabel 11594 JZ-600-Y-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11464_EN_GB_1.pdf?v=1772609466\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 7C Helukabel 11594 JZ-600-Y-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a connection and control cable in machine tools, assembly lines and conveyor belts, production lines, plant construction, heating and air-conditioning technology and in smelters and steel mills. Suitable for flexible applications involving medium mechanical\u003cbr\u003estress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, as well as outdoors (fixed installation). May not be laid directly in soil (suitable for direct burial starting with an outer diameter of 20 mm) or water. Due to its extended nominal voltage range and good UV resistance, this cable is primarily used in Southern Europe, Arabic, Asian and Eastern countries. Due to the high screening density, interference-free transmission of signals or pulses is ensured. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding. \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"153\" data-start=\"124\"\u003e12 AWG 7C JZ 600 Y CY Control Cable JZ 600 Y CY Control Cable PVC Shielded Control Cable Flexible PVC Connection Cable Series 12 AWG 7C Control Cable Shielded PVC Control Cable Flexible PVC Armored Cable 12 AWG 7C JZ 600-Y PVC Control Cable JZ 600-Y PVC  Control Cable PVC Shielded Cable PVC CY Shielded Control Cable Flexible Shielded Connection Cable\u003cstrong data-end=\"289\" data-start=\"257\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable in alignment with DIN VDE 0262, DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eFlexible -15°C to +80°C\u003cbr\u003eFixed -40°C to +80°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 600\/1000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e8000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eFlexible 10x Outer-Ø\u003cbr\u003eFixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: black (RAL 9005)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Resistant to: UV radiation, weathering effects\u003cbr\u003e• Largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• For outdoor use\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• UV-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Weather-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size :\u003c\/b\u003e 12 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 7 G 4\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e19.0\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 385.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 775.0\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63262754275697,"sku":"NNC11594","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_9879a4c9-ec32-48d4-bacc-774cd2a74ac4.png?v=1772691247"},{"product_id":"12-awg-12c-helukabel-11596-jz-600-y-cy-pvc-control-and-connection-cable","title":"12 AWG 12C Helukabel 11596 JZ-600-Y-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11464_EN_GB_1.pdf?v=1772609466\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 12C Helukabel 11596 JZ-600-Y-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a connection and control cable in machine tools, assembly lines and conveyor belts, production lines, plant construction, heating and air-conditioning technology and in smelters and steel mills. Suitable for flexible applications involving medium mechanical\u003cbr\u003estress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, as well as outdoors (fixed installation). May not be laid directly in soil (suitable for direct burial starting with an outer diameter of 20 mm) or water. Due to its extended nominal voltage range and good UV resistance, this cable is primarily used in Southern Europe, Arabic, Asian and Eastern countries. Due to the high screening density, interference-free transmission of signals or pulses is ensured. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding. \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"153\" data-start=\"124\"\u003e12 AWG 12C JZ 600 Y CY Control Cable JZ 600 Y CY Control Cable PVC Shielded Control Cable Flexible PVC Connection Cable Series 12 AWG 12C Control Cable Shielded PVC Control Cable Flexible PVC Armored Cable 12 AWG 12C JZ 600-Y PVC Control Cable JZ 600-Y PVC  Control Cable PVC Shielded Cable PVC CY Shielded Control Cable Flexible Shielded Connection Cable\u003cstrong data-end=\"289\" data-start=\"257\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable in alignment with DIN VDE 0262, DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eFlexible -15°C to +80°C\u003cbr\u003eFixed -40°C to +80°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 600\/1000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e8000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eFlexible 10x Outer-Ø\u003cbr\u003eFixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: black (RAL 9005)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Resistant to: UV radiation, weathering effects\u003cbr\u003e• Largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• For outdoor use\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• UV-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Weather-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size :\u003c\/b\u003e 12 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 12 G 4 \u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e25.5\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 581.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 1244.0\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63262754537841,"sku":"NNC11596","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_9879a4c9-ec32-48d4-bacc-774cd2a74ac4.png?v=1772691247"},{"product_id":"12-awg-12c-helukabel-11024506-oz-600-y-cy-pvc-control-and-connection-cable","title":"12 AWG 12C Helukabel 11024506 OZ-600-Y-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11464_EN_GB_1.pdf?v=1772609466\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e12 AWG 12C Helukabel 11024506 OZ-600-Y-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a connection and control cable in machine tools, assembly lines and conveyor belts, production lines, plant construction, heating and air-conditioning technology and in smelters and steel mills. Suitable for flexible applications involving medium mechanical\u003cbr\u003estress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, as well as outdoors (fixed installation). May not be laid directly in soil (suitable for direct burial starting with an outer diameter of 20 mm) or water. Due to its extended nominal voltage range and good UV resistance, this cable is primarily used in Southern Europe, Arabic, Asian and Eastern countries. Due to the high screening density, interference-free transmission of signals or pulses is ensured. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding. \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"153\" data-start=\"124\"\u003e12 AWG 12C OZ 600 Y CY Control Cable OZ 600 Y CY Control Cable PVC Shielded Control Cable Flexible PVC Connection Cable Series 12 AWG 12C Control Cable Shielded PVC Control Cable Flexible PVC Armored Cable 12 AWG 12C OZ 600-Y PVC Control Cable OZ 600-Y PVC  Control Cable PVC Shielded Cable PVC CY Shielded Control Cable Flexible Shielded Connection Cable\u003cstrong data-end=\"289\" data-start=\"257\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable in alignment with DIN VDE 0262, DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eFlexible -15°C to +80°C\u003cbr\u003eFixed -40°C to +80°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 600\/1000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e8000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eFlexible 10x Outer-Ø\u003cbr\u003eFixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: black (RAL 9005)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Resistant to: UV radiation, weathering effects\u003cbr\u003e• Largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• For outdoor use\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• UV-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Weather-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size :\u003c\/b\u003e 12 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 12 x 4\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e25.5\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 581.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 1244.0\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63262754931057,"sku":"NNC11024506","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design-Photoroom_baecf753-6698-47bc-9db3-f711026d37bb.png?v=1772689423"},{"product_id":"10-awg-2c-helukabel-11597-oz-600-y-cy-pvc-control-and-connection-cable","title":"10 AWG 2C Helukabel 11597 OZ-600-Y-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11464_EN_GB_1.pdf?v=1772609466\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e10 AWG 2C Helukabel 11597 OZ-600-Y-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a connection and control cable in machine tools, assembly lines and conveyor belts, production lines, plant construction, heating and air-conditioning technology and in smelters and steel mills. Suitable for flexible applications involving medium mechanical\u003cbr\u003estress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, as well as outdoors (fixed installation). May not be laid directly in soil (suitable for direct burial starting with an outer diameter of 20 mm) or water. Due to its extended nominal voltage range and good UV resistance, this cable is primarily used in Southern Europe, Arabic, Asian and Eastern countries. Due to the high screening density, interference-free transmission of signals or pulses is ensured. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding. \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"153\" data-start=\"124\"\u003e10 AWG 2C OZ 600 Y CY Control Cable OZ 600 Y CY Control Cable PVC Shielded Control Cable Flexible PVC Connection Cable Series 10 AWG 2C Control Cable Shielded PVC Control Cable Flexible PVC Armored Cable 10 AWG 2C OZ 600-Y PVC Control Cable OZ 600-Y PVC  Control Cable PVC Shielded Cable PVC CY Shielded Control Cable Flexible Shielded Connection Cable\u003cstrong data-end=\"289\" data-start=\"257\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable in alignment with DIN VDE 0262, DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eFlexible -15°C to +80°C\u003cbr\u003eFixed -40°C to +80°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 600\/1000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e8000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eFlexible 10x Outer-Ø\u003cbr\u003eFixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: black (RAL 9005)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Resistant to: UV radiation, weathering effects\u003cbr\u003e• Largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• For outdoor use\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• UV-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Weather-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size :\u003c\/b\u003e 10 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 2 x 6\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e15.2\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 176.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 433.0\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63262757847409,"sku":"NNC11597","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design-Photoroom_baecf753-6698-47bc-9db3-f711026d37bb.png?v=1772689423"},{"product_id":"10-awg-3c-helukabel-11598-jz-600-y-cy-pvc-control-and-connection-cable","title":"10 AWG 3C Helukabel 11598 JZ-600-Y-CY PVC Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11464_EN_GB_1.pdf?v=1772609466\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e10 AWG 3C Helukabel 11598 JZ-600-Y-CY PVC Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eUsed as a connection and control cable in machine tools, assembly lines and conveyor belts, production lines, plant construction, heating and air-conditioning technology and in smelters and steel mills. Suitable for flexible applications involving medium mechanical\u003cbr\u003estress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, as well as outdoors (fixed installation). May not be laid directly in soil (suitable for direct burial starting with an outer diameter of 20 mm) or water. Due to its extended nominal voltage range and good UV resistance, this cable is primarily used in Southern Europe, Arabic, Asian and Eastern countries. Due to the high screening density, interference-free transmission of signals or pulses is ensured. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding. \u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003cstrong data-end=\"162\" data-start=\"132\"\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"153\" data-start=\"124\"\u003e10 AWG 3C JZ 600 Y CY Control Cable JZ 600 Y CY Control Cable PVC Shielded Control Cable Flexible PVC Connection Cable Series 10 AWG 3C Control Cable Shielded PVC Control Cable Flexible PVC Armored Cable 10 AWG 3C JZ 600-Y PVC Control Cable JZ 600-Y PVC  Control Cable PVC Shielded Cable PVC CY Shielded Control Cable Flexible Shielded Connection Cable\u003cstrong data-end=\"289\" data-start=\"257\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003ePVC control and connection cable in alignment with DIN VDE 0262, DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eFlexible -15°C to +80°C\u003cbr\u003eFixed -40°C to +80°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 600\/1000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBreakdown voltage\u003cbr\u003e\u003c\/strong\u003e8000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling resistance\u003cbr\u003e\u003c\/strong\u003eat 30 MHz, approx. 250 Ohm\/ km\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eFlexible 10x Outer-Ø\u003cbr\u003eFixed 5x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: PVC acc. to DIN VDE 0207-363-3 \/ DIN EN 50363-3 (compound type TI2)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer,\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Inner sheath: PVC\u003cbr\u003e• Screen: braided screen of tinned copper wires, approx. coverage 85%\u003cbr\u003e• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 \/ DIN EN 50363-4-1 (compound type TM2)\u003cbr\u003e• Sheath colour: black (RAL 9005)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Resistant to: UV radiation, weathering effects\u003cbr\u003e• Largely resistant to: oil, for details, see \"Technical Information\"\u003cbr\u003e• For outdoor use\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332- 1-2 \/ IEC 60332-1-2\u003cbr\u003e• UV-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Weather-resistant acc. to DIN EN ISO 4892-2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size :\u003c\/b\u003e 10 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²:\u003c\/b\u003e 3 G 6\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e16.2\u003cb\u003e\u003cbr\u003e• Cu factor per km:\u003c\/b\u003e 245.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 572.0\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63262760108401,"sku":"NNC11598","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_9879a4c9-ec32-48d4-bacc-774cd2a74ac4.png?v=1772691247"}],"url":"https:\/\/nassaunationalcable.com\/collections\/helukabel-jz-600-y-cy-oz-600-y-cy-pvc-control-and-connection-cable.oembed","provider":"NassauNationalCable","version":"1.0","type":"link"}