{"title":"HELUKABEL JZ-500 HMH \/ OZ-500 HMH HIGHLY FLAME RETARDANT CONTROL AND CONNECTION CABLE","description":"\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003eHELUKABEL JZ-500 HMH \/ OZ-500 HMH HIGHLY FLAME RETARDANT CONTROL AND CONNECTION CABLE\u003c\/span\u003e\u003c\/h2\u003e","products":[{"product_id":"helukabel-jz-500-hmh-oz-500-hmh-highly-flame-retardant-control-and-connection-cable-1","title":"HELUKABEL JZ-500 HMH \/ OZ-500 HMH HIGHLY FLAME RETARDANT CONTROL AND CONNECTION CABLE","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11201_EN_GB_2.pdf?v=1770107340\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003eHELUKABEL JZ-500 HMH \/ OZ-500 HMH HIGHLY FLAME RETARDANT CONTROL AND CONNECTION CABLE\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003eHMH = Halogen-free, 500 HMH, Halogen-free polymer, Flame-retardant, Low smoke density, Low corrosive gas emission, Tool machines, Conveyor belts, Production \u0026amp; assembly lines, Plant and factory wiring, Air-conditioning systems, Steel, rolling \u0026amp; metallurgical plants, Flexible use with occasional movement, Dry, damp, and wet areas.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363-7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• Halogen-free\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332-1-2 \/ IEC 60332-1-2\u003cbr\u003e• Bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332-3-24 \/ IEC 60332-3-24\u003cbr\u003e• Smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034-1+2 \/ IEC 61034-1+2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• Please note \"cleanroom qualification\" in your order\u003cbr\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63145978134897,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PMLL_3_9aeac3a3-679d-479f-8fc1-f4628885d456.png?v=1770106846"},{"product_id":"20-awg-2c-helukabel-11201-oz-500-hmh-highly-flame-retardant-control-and-connection-cable-1","title":"20 AWG 2C Helukabel 11201 OZ-500 HMH Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11201_EN_GB_2.pdf?v=1770107340\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 2C Helukabel 11201 OZ-500 HMH Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e20 AWG 2C HMH = Halogen-free, 500 HMH, Halogen-free polymer, Flame-retardant, Low smoke density, Low corrosive gas emission, 20 AWG 2C Tool machines, Conveyor belts, Production \u0026amp; assembly lines, 20 AWG 2C Plant and factory wiring, Air-conditioning systems, Steel, rolling \u0026amp; metallurgical plants, Flexible use with occasional movement, Dry, damp, and wet areas.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363-7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• Halogen-free\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332-1-2 \/ IEC 60332-1-2\u003cbr\u003e• Bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332-3-24 \/ IEC 60332-3-24\u003cbr\u003e• Smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034-1+2 \/ IEC 61034-1+2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• Please note \"cleanroom qualification\" in your order\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size : \u003c\/b\u003e20 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²: \u003c\/b\u003e2 x 0.5\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e4.8\u003cb\u003e\u003cbr\u003e• Cu factor per km: \u003c\/b\u003e9.6\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx: \u003c\/b\u003e43.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63150824161649,"sku":"NNC11201","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PML.png?v=1770268396"},{"product_id":"20-awg-3c-helukabel-11202-jz-500-hmh-highly-flame-retardant-control-and-connection-cable","title":"20 AWG 3C Helukabe1 1202JZ-500 HMH Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11201_EN_GB_2.pdf?v=1770107340\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 3C Helukabel 11202 JZ-500 HMH Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e20 AWG 3C HMH = Halogen-free, 500 HMH, Halogen-free polymer, Flame-retardant, Low smoke density, Low corrosive gas emission, 20 AWG 3C Tool machines, Conveyor belts, Production \u0026amp; assembly lines, 20 AWG 3C Plant and factory wiring, Air-conditioning systems, Steel, rolling \u0026amp; metallurgical plants, Flexible use with occasional movement, Dry, damp, and wet areas.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363-7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• Halogen-free\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332-1-2 \/ IEC 60332-1-2\u003cbr\u003e• Bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332-3-24 \/ IEC 60332-3-24\u003cbr\u003e• Smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034-1+2 \/ IEC 61034-1+2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• Please note \"cleanroom qualification\" in your order\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size : \u003c\/b\u003e20 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²: \u003c\/b\u003e3 G 0.5\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e5.1\u003cb\u003e\u003cbr\u003e• Cu factor per km: \u003c\/b\u003e14.4\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx: \u003c\/b\u003e50.0\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman';\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63150833041777,"sku":"NNC11202","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PML.png?v=1770268396"},{"product_id":"20-awg-3c-helukabel-11202-oz-500-hmh-highly-flame-retardant-control-and-connection-cable","title":"20 AWG 3C Helukabel 11332 OZ-500 HMH Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11201_EN_GB_2.pdf?v=1770107340\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 3C Helukabel 11202 OZ-500 HMH Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e20 AWG 3C HMH = Halogen-free, 500 HMH, Halogen-free polymer, Flame-retardant, Low smoke density, Low corrosive gas emission, 20 AWG 3C Tool machines, Conveyor belts, Production \u0026amp; assembly lines, 20 AWG 3C Plant and factory wiring, Air-conditioning systems, Steel, rolling \u0026amp; metallurgical plants, Flexible use with occasional movement, Dry, damp, and wet areas.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363-7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• Halogen-free\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332-1-2 \/ IEC 60332-1-2\u003cbr\u003e• Bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332-3-24 \/ IEC 60332-3-24\u003cbr\u003e• Smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034-1+2 \/ IEC 61034-1+2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• Please note \"cleanroom qualification\" in your order\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size : \u003c\/b\u003e20 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²: \u003c\/b\u003e3 x 0.5\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e5.1\u003cb\u003e\u003cbr\u003e• Cu factor per km: \u003c\/b\u003e14.4\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx: \u003c\/b\u003e50.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63150940094833,"sku":"NNC11332","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PML.png?v=1770268396"},{"product_id":"20-awg-4c-helukabel-11202-jz-500-hmh-highly-flame-retardant-control-and-connection-cable-1","title":"20 AWG 4C Helukabel 11203 JZ-500 HMH Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11201_EN_GB_2.pdf?v=1770107340\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 4C Helukabel 11202 JZ-500 HMH Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e20 AWG 4C HMH = Halogen-free, 500 HMH, Halogen-free polymer, Flame-retardant, Low smoke density, Low corrosive gas emission, 20 AWG 4C Tool machines, Conveyor belts, Production \u0026amp; assembly lines, 20 AWG 4C Plant and factory wiring, Air-conditioning systems, Steel, rolling \u0026amp; metallurgical plants, Flexible use with occasional movement, Dry, damp, and wet areas.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363-7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• Halogen-free\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332-1-2 \/ IEC 60332-1-2\u003cbr\u003e• Bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332-3-24 \/ IEC 60332-3-24\u003cbr\u003e• Smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034-1+2 \/ IEC 61034-1+2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• Please note \"cleanroom qualification\" in your order\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size : \u003c\/b\u003e20 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²: \u003c\/b\u003e4 G 0.5\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e5.5\u003cb\u003e\u003cbr\u003e• Cu factor per km: \u003c\/b\u003e19.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx: \u003c\/b\u003e60.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63150954578289,"sku":"NNC11203","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PMLL.png?v=1770272437"},{"product_id":"20-awg-4c-helukabel-11202-oz-500-hmh-highly-flame-retardant-control-and-connection-cable","title":"20 AWG 4C Helukabel 11333 OZ-500 HMH Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11201_EN_GB_2.pdf?v=1770107340\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 4C Helukabel 11202 OZ-500 HMH Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e20 AWG 4C HMH = Halogen-free, 500 HMH, Halogen-free polymer, Flame-retardant, Low smoke density, Low corrosive gas emission, 20 AWG 4C Tool machines, Conveyor belts, Production \u0026amp; assembly lines, 20 AWG 4C Plant and factory wiring, Air-conditioning systems, Steel, rolling \u0026amp; metallurgical plants, Flexible use with occasional movement, Dry, damp, and wet areas.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363-7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• Halogen-free\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332-1-2 \/ IEC 60332-1-2\u003cbr\u003e• Bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332-3-24 \/ IEC 60332-3-24\u003cbr\u003e• Smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034-1+2 \/ IEC 61034-1+2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• Please note \"cleanroom qualification\" in your order\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size : \u003c\/b\u003e20 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²: \u003c\/b\u003e4 x 0.5\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e5.5\u003cb\u003e\u003cbr\u003e• Cu factor per km: \u003c\/b\u003e19.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx: \u003c\/b\u003e60.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63150954873201,"sku":"NNC11333","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PML_85b79683-a2bb-4b4b-b91d-002b9135a24d.png?v=1770272915"},{"product_id":"20-awg-5c-helukabel-11204-jz-500-hmh-highly-flame-retardant-control-and-connection-cable","title":"20 AWG 5C Helukabel 11204 JZ-500 HMH Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11201_EN_GB_2.pdf?v=1770107340\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 5C Helukabel 11204 JZ-500 HMH Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e20 AWG 5C HMH = Halogen-free, 500 HMH, Halogen-free polymer, Flame-retardant, Low smoke density, Low corrosive gas emission, 20 AWG 5C Tool machines, Conveyor belts, Production \u0026amp; assembly lines, 20 AWG 5C Plant and factory wiring, Air-conditioning systems, Steel, rolling \u0026amp; metallurgical plants, Flexible use with occasional movement, Dry, damp, and wet areas.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363-7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• Halogen-free\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332-1-2 \/ IEC 60332-1-2\u003cbr\u003e• Bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332-3-24 \/ IEC 60332-3-24\u003cbr\u003e• Smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034-1+2 \/ IEC 61034-1+2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• Please note \"cleanroom qualification\" in your order\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size : \u003c\/b\u003e20 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²: \u003c\/b\u003e5 G 0.5\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e6.2\u003cb\u003e\u003cbr\u003e• Cu factor per km: \u003c\/b\u003e24.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx: \u003c\/b\u003e71.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63150973976945,"sku":"NNC11204","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PMLL.png?v=1770272437"},{"product_id":"20-awg-5c-helukabel-11334-oz-500-hmh-highly-flame-retardant-control-and-connection-cable","title":"20 AWG 5C Helukabel 11334 OZ-500 HMH Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11201_EN_GB_2.pdf?v=1770107340\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 5C Helukabel 11334 OZ-500 HMH Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e20 AWG 5C HMH = Halogen-free, 500 HMH, Halogen-free polymer, Flame-retardant, Low smoke density, Low corrosive gas emission, 20 AWG 5C Tool machines, Conveyor belts, Production \u0026amp; assembly lines, 20 AWG 5C Plant and factory wiring, Air-conditioning systems, Steel, rolling \u0026amp; metallurgical plants, Flexible use with occasional movement, Dry, damp, and wet areas.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363-7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• Halogen-free\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332-1-2 \/ IEC 60332-1-2\u003cbr\u003e• Bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332-3-24 \/ IEC 60332-3-24\u003cbr\u003e• Smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034-1+2 \/ IEC 61034-1+2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• Please note \"cleanroom qualification\" in your order\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size : \u003c\/b\u003e20 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²: \u003c\/b\u003e5 x 0.5\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e6.2\u003cb\u003e\u003cbr\u003e• Cu factor per km: \u003c\/b\u003e24.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx: \u003c\/b\u003e71.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63150987706737,"sku":"NNC11334","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PML_85b79683-a2bb-4b4b-b91d-002b9135a24d.png?v=1770272915"},{"product_id":"20-awg-7c-helukabel-11205-jz-500-hmh-highly-flame-retardant-control-and-connection-cable","title":"20 AWG 7C Helukabel 11205 JZ-500 HMH Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11201_EN_GB_2.pdf?v=1770107340\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e20 AWG 7C Helukabel 11205 JZ-500 HMH Highly flame retardant Control and Connection Cable\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e20 AWG 7C HMH = Halogen-free, 500 HMH, Halogen-free polymer, Flame-retardant, Low smoke density, Low corrosive gas emission, 20 AWG 7C Tool machines, Conveyor belts, Production \u0026amp; assembly lines, 20 AWG 7C Plant and factory wiring, Air-conditioning systems, Steel, rolling \u0026amp; metallurgical plants, Flexible use with occasional movement, Dry, damp, and wet areas.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363-7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• Halogen-free\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332-1-2 \/ IEC 60332-1-2\u003cbr\u003e• Bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332-3-24 \/ IEC 60332-3-24\u003cbr\u003e• Smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034-1+2 \/ IEC 61034-1+2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• Please note \"cleanroom qualification\" in your order\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size : \u003c\/b\u003e20 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²: \u003c\/b\u003e7 G 0.5\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e6.7\u003cb\u003e\u003cbr\u003e• Cu factor per km: \u003c\/b\u003e33.6\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx: \u003c\/b\u003e84.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63150989050225,"sku":"NNC11205","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PMLL.png?v=1770272437"},{"product_id":"20-awg-8c-helukabel-11206-jz-500-hmh-highly-flame-retardant-control-and-connection-cable","title":"20 AWG 8C Helukabel 11206 JZ-500 HMH Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11201_EN_GB_2.pdf?v=1770107340\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 8C Helukabel 11206 JZ-500 HMH Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e20 AWG 8C HMH = Halogen-free, 500 HMH, Halogen-free polymer, Flame-retardant, Low smoke density, Low corrosive gas emission, 20 AWG 8C Tool machines, Conveyor belts, Production \u0026amp; assembly lines, 20 AWG 8C Plant and factory wiring, Air-conditioning systems, Steel, rolling \u0026amp; metallurgical plants, Flexible use with occasional movement, Dry, damp, and wet areas.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363-7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• Halogen-free\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332-1-2 \/ IEC 60332-1-2\u003cbr\u003e• Bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332-3-24 \/ IEC 60332-3-24\u003cbr\u003e• Smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034-1+2 \/ IEC 61034-1+2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• Please note \"cleanroom qualification\" in your order\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size : \u003c\/b\u003e20 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²: \u003c\/b\u003e8 G 0.5\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e7.4\u003cb\u003e\u003cbr\u003e• Cu factor per km: \u003c\/b\u003e38.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx: \u003c\/b\u003e101.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63151023161713,"sku":"NNC11206","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PMLL.png?v=1770272437"},{"product_id":"20-awg-10c-helukabel-11207-jz-500-hmh-highly-flame-retardant-control-and-connection-cable","title":"20 AWG 10C Helukabel 11207 JZ-500 HMH Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11201_EN_GB_2.pdf?v=1770107340\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 10C Helukabel 11207 JZ-500 HMH Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e20 AWG 10C HMH = Halogen-free, 500 HMH, Halogen-free polymer, Flame-retardant, Low smoke density, Low corrosive gas emission, 20 AWG 10C Tool machines, Conveyor belts, Production \u0026amp; assembly lines, 20 AWG 10C Plant and factory wiring, Air-conditioning systems, Steel, rolling \u0026amp; metallurgical plants, Flexible use with occasional movement, Dry, damp, and wet areas.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363-7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• Halogen-free\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332-1-2 \/ IEC 60332-1-2\u003cbr\u003e• Bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332-3-24 \/ IEC 60332-3-24\u003cbr\u003e• Smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034-1+2 \/ IEC 61034-1+2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• Please note \"cleanroom qualification\" in your order\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size : \u003c\/b\u003e20 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²: \u003c\/b\u003e10 G 0.5\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e8.6\u003cb\u003e\u003cbr\u003e• Cu factor per km: \u003c\/b\u003e48.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx: \u003c\/b\u003e121.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63151028044145,"sku":"NNC11207","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PMLL.png?v=1770272437"},{"product_id":"20-awg-12c-helukabel-11208-jz-500-hmh-highly-flame-retardant-control-and-connection-cable","title":"20 AWG 12C Helukabel 11208 JZ-500 HMH Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11201_EN_GB_2.pdf?v=1770107340\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 12C Helukabel 11208 JZ-500 HMH Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e20 AWG 12C HMH = Halogen-free, 500 HMH, Halogen-free polymer, Flame-retardant, Low smoke density, Low corrosive gas emission, 20 AWG 12C Tool machines, Conveyor belts, Production \u0026amp; assembly lines, 20 AWG 12C Plant and factory wiring, Air-conditioning systems, Steel, rolling \u0026amp; metallurgical plants, Flexible use with occasional movement, Dry, damp, and wet areas.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363-7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• Halogen-free\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332-1-2 \/ IEC 60332-1-2\u003cbr\u003e• Bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332-3-24 \/ IEC 60332-3-24\u003cbr\u003e• Smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034-1+2 \/ IEC 61034-1+2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• Please note \"cleanroom qualification\" in your order\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size : \u003c\/b\u003e20 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²: \u003c\/b\u003e12 G 0.5\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e9.1\u003cb\u003e\u003cbr\u003e• Cu factor per km: \u003c\/b\u003e58.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx: \u003c\/b\u003e142.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63151034466673,"sku":"NNC11208","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PMLL.png?v=1770272437"},{"product_id":"20-awg-16c-helukabel-11209-jz-500-hmh-highly-flame-retardant-control-and-connection-cable","title":"20 AWG 16C Helukabel 11209 JZ-500 HMH Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11201_EN_GB_2.pdf?v=1770107340\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 16C Helukabel 11209 JZ-500 HMH Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e20 AWG 16C HMH = Halogen-free, 500 HMH, Halogen-free polymer, Flame-retardant, Low smoke density, Low corrosive gas emission, 20 AWG 16C Tool machines, Conveyor belts, Production \u0026amp; assembly lines, 20 AWG 16C Plant and factory wiring, Air-conditioning systems, Steel, rolling \u0026amp; metallurgical plants, Flexible use with occasional movement, Dry, damp, and wet areas.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363-7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• Halogen-free\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332-1-2 \/ IEC 60332-1-2\u003cbr\u003e• Bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332-3-24 \/ IEC 60332-3-24\u003cbr\u003e• Smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034-1+2 \/ IEC 61034-1+2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• Please note \"cleanroom qualification\" in your order\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size : \u003c\/b\u003e20 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²: \u003c\/b\u003e16 G 0.5\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e10.0\u003cb\u003e\u003cbr\u003e• Cu factor per km: \u003c\/b\u003e76.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx: \u003c\/b\u003e183.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63151038628209,"sku":"NNC11209","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PMLL.png?v=1770272437"},{"product_id":"20-awg-18c-helukabel-11210-jz-500-hmh-highly-flame-retardant-control-and-connection-cable","title":"20 AWG 18C Helukabel 11210 JZ-500 HMH Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11201_EN_GB_2.pdf?v=1770107340\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 18C Helukabel 11210 JZ-500 HMH Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e20 AWG 18C HMH = Halogen-free, 500 HMH, Halogen-free polymer, Flame-retardant, Low smoke density, Low corrosive gas emission, 20 AWG 18C Tool machines, Conveyor belts, Production \u0026amp; assembly lines, 20 AWG 18C Plant and factory wiring, Air-conditioning systems, Steel, rolling \u0026amp; metallurgical plants, Flexible use with occasional movement, Dry, damp, and wet areas.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363-7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• Halogen-free\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332-1-2 \/ IEC 60332-1-2\u003cbr\u003e• Bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332-3-24 \/ IEC 60332-3-24\u003cbr\u003e• Smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034-1+2 \/ IEC 61034-1+2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• Please note \"cleanroom qualification\" in your order\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size : \u003c\/b\u003e20 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²: \u003c\/b\u003e18 G 0.5\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e10.7\u003cb\u003e\u003cbr\u003e• Cu factor per km: \u003c\/b\u003e86.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx: \u003c\/b\u003e204.0\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63151040659825,"sku":"NNC11210","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PMLL.png?v=1770272437"},{"product_id":"20-awg-20c-helukabel-11211-jz-500-hmh-highly-flame-retardant-control-and-connection-cable","title":"20 AWG 20C Helukabel 11211 JZ-500 HMH Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11201_EN_GB_2.pdf?v=1770107340\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 20C Helukabel 11211 JZ-500 HMH Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e20 AWG 20C HMH = Halogen-free, 500 HMH, Halogen-free polymer, Flame-retardant, Low smoke density, Low corrosive gas emission, 20 AWG 20C Tool machines, Conveyor belts, Production \u0026amp; assembly lines, 20 AWG 20C Plant and factory wiring, Air-conditioning systems, Steel, rolling \u0026amp; metallurgical plants, Flexible use with occasional movement, Dry, damp, and wet areas.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363-7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• Halogen-free\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332-1-2 \/ IEC 60332-1-2\u003cbr\u003e• Bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332-3-24 \/ IEC 60332-3-24\u003cbr\u003e• Smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034-1+2 \/ IEC 61034-1+2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• Please note \"cleanroom qualification\" in your order\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size : \u003c\/b\u003e20 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²: \u003c\/b\u003e20 G 0.5\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e11.3\u003cb\u003e\u003cbr\u003e• Cu factor per km: \u003c\/b\u003e96.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx: \u003c\/b\u003e227.0\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63151042593137,"sku":"NNC11211","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PMLL.png?v=1770272437"},{"product_id":"20-awg-25c-helukabel-11212-jz-500-hmh-highly-flame-retardant-control-and-connection-cable","title":"20 AWG 25C Helukabel 11212 JZ-500 HMH Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11201_EN_GB_2.pdf?v=1770107340\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 25C Helukabel 11212 JZ-500 HMH Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e20 AWG 25C HMH = Halogen-free, 500 HMH, Halogen-free polymer, Flame-retardant, Low smoke density, Low corrosive gas emission, 20 AWG 25C Tool machines, Conveyor belts, Production \u0026amp; assembly lines, 20 AWG 25C Plant and factory wiring, Air-conditioning systems, Steel, rolling \u0026amp; metallurgical plants, Flexible use with occasional movement, Dry, damp, and wet areas.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363-7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• Halogen-free\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332-1-2 \/ IEC 60332-1-2\u003cbr\u003e• Bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332-3-24 \/ IEC 60332-3-24\u003cbr\u003e• Smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034-1+2 \/ IEC 61034-1+2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• Please note \"cleanroom qualification\" in your order\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size : \u003c\/b\u003e20 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²: \u003c\/b\u003e25 G 0.5\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e12.6\u003cb\u003e\u003cbr\u003e• Cu factor per km: \u003c\/b\u003e120.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx: \u003c\/b\u003e283.0\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63151044559217,"sku":"NNC11212","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PMLL.png?v=1770272437"},{"product_id":"20-awg-30c-helukabel-11213-jz-500-hmh-highly-flame-retardant-control-and-connection-cable","title":"20 AWG 30C Helukabel 11213 JZ-500 HMH Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11201_EN_GB_2.pdf?v=1770107340\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 30C Helukabel 11213 JZ-500 HMH Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e20 AWG 30C HMH = Halogen-free, 500 HMH, Halogen-free polymer, Flame-retardant, Low smoke density, Low corrosive gas emission, 20 AWG 30C Tool machines, Conveyor belts, Production \u0026amp; assembly lines, 20 AWG 30C Plant and factory wiring, Air-conditioning systems, Steel, rolling \u0026amp; metallurgical plants, Flexible use with occasional movement, Dry, damp, and wet areas.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363-7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• Halogen-free\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332-1-2 \/ IEC 60332-1-2\u003cbr\u003e• Bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332-3-24 \/ IEC 60332-3-24\u003cbr\u003e• Smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034-1+2 \/ IEC 61034-1+2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• Please note \"cleanroom qualification\" in your order\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size : \u003c\/b\u003e20 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²: \u003c\/b\u003e30 G 0.5\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e13.5\u003cb\u003e\u003cbr\u003e• Cu factor per km: \u003c\/b\u003e144.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx: \u003c\/b\u003e324.0\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63151046984049,"sku":"NNC11213","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PMLL.png?v=1770272437"},{"product_id":"20-awg-34c-helukabel-11214-jz-500-hmh-highly-flame-retardant-control-and-connection-cable","title":"20 AWG 34C Helukabel 11214 JZ-500 HMH Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11201_EN_GB_2.pdf?v=1770107340\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 34C Helukabel 11214 JZ-500 HMH Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e20 AWG 34C HMH = Halogen-free, 500 HMH, Halogen-free polymer, Flame-retardant, Low smoke density, Low corrosive gas emission, 20 AWG 34C Tool machines, Conveyor belts, Production \u0026amp; assembly lines, 20 AWG 34C Plant and factory wiring, Air-conditioning systems, Steel, rolling \u0026amp; metallurgical plants, Flexible use with occasional movement, Dry, damp, and wet areas.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363-7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• Halogen-free\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332-1-2 \/ IEC 60332-1-2\u003cbr\u003e• Bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332-3-24 \/ IEC 60332-3-24\u003cbr\u003e• Smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034-1+2 \/ IEC 61034-1+2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• Please note \"cleanroom qualification\" in your order\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size : \u003c\/b\u003e20 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²: \u003c\/b\u003e34 G 0.5\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e14.7\u003cb\u003e\u003cbr\u003e• Cu factor per km: \u003c\/b\u003e163.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 367.0\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63151047541105,"sku":"NNC11214","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PMLL.png?v=1770272437"},{"product_id":"20-awg-37c-helukabel-11215-jz-500-hmh-highly-flame-retardant-control-and-connection-cable","title":"20 AWG 37C Helukabel 11215 JZ-500 HMH Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11201_EN_GB_2.pdf?v=1770107340\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 37C Helukabel 11215 JZ-500 HMH Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e20 AWG 37C HMH = Halogen-free, 500 HMH, Halogen-free polymer, Flame-retardant, Low smoke density, Low corrosive gas emission, 20 AWG 37C Tool machines, Conveyor belts, Production \u0026amp; assembly lines, 20 AWG 37C Plant and factory wiring, Air-conditioning systems, Steel, rolling \u0026amp; metallurgical plants, Flexible use with occasional movement, Dry, damp, and wet areas.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363-7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• Halogen-free\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332-1-2 \/ IEC 60332-1-2\u003cbr\u003e• Bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332-3-24 \/ IEC 60332-3-24\u003cbr\u003e• Smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034-1+2 \/ IEC 61034-1+2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• Please note \"cleanroom qualification\" in your order\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size : \u003c\/b\u003e20 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²: \u003c\/b\u003e37 G 0.5\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e14.7\u003cb\u003e\u003cbr\u003e• Cu factor per km: \u003c\/b\u003e178.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 381.0\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63151050260849,"sku":"NNC11215","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PMLL.png?v=1770272437"},{"product_id":"20-awg-41c-helukabel-11216-jz-500-hmh-highly-flame-retardant-control-and-connection-cable","title":"20 AWG 41C Helukabel 11216 JZ-500 HMH Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11201_EN_GB_2.pdf?v=1770107340\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 41C Helukabel 11216 JZ-500 HMH Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e20 AWG 41C HMH = Halogen-free, 500 HMH, Halogen-free polymer, Flame-retardant, Low smoke density, Low corrosive gas emission, 20 AWG 41C Tool machines, Conveyor belts, Production \u0026amp; assembly lines, 20 AWG 41C Plant and factory wiring, Air-conditioning systems, Steel, rolling \u0026amp; metallurgical plants, Flexible use with occasional movement, Dry, damp, and wet areas.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363-7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• Halogen-free\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332-1-2 \/ IEC 60332-1-2\u003cbr\u003e• Bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332-3-24 \/ IEC 60332-3-24\u003cbr\u003e• Smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034-1+2 \/ IEC 61034-1+2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• Please note \"cleanroom qualification\" in your order\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size : \u003c\/b\u003e20 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²: \u003c\/b\u003e41 G 0.5\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e15.8\u003cb\u003e\u003cbr\u003e• Cu factor per km: \u003c\/b\u003e197.0 \u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 417.0\u003cbr\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63151052423537,"sku":"NNC11216","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PMLL.png?v=1770272437"},{"product_id":"20-awg-42c-helukabel-11217-jz-500-hmh-highly-flame-retardant-control-and-connection-cable","title":"20 AWG 42C Helukabel 11217 JZ-500 HMH Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11201_EN_GB_2.pdf?v=1770107340\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 42C Helukabel 11217 JZ-500 HMH Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e20 AWG 42C HMH = Halogen-free, 500 HMH, Halogen-free polymer, Flame-retardant, Low smoke density, Low corrosive gas emission, 20 AWG 42C Tool machines, Conveyor belts, Production \u0026amp; assembly lines, 20 AWG 42C Plant and factory wiring, Air-conditioning systems, Steel, rolling \u0026amp; metallurgical plants, Flexible use with occasional movement, Dry, damp, and wet areas.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363-7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• Halogen-free\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332-1-2 \/ IEC 60332-1-2\u003cbr\u003e• Bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332-3-24 \/ IEC 60332-3-24\u003cbr\u003e• Smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034-1+2 \/ IEC 61034-1+2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• Please note \"cleanroom qualification\" in your order\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size : \u003c\/b\u003e20 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²: \u003c\/b\u003e42 G 0.5\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e15.8\u003cb\u003e\u003cbr\u003e• Cu factor per km: \u003c\/b\u003e202.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 454.0\u003cbr\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63151054848369,"sku":"NNC11217","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PMLL.png?v=1770272437"},{"product_id":"20-awg-50c-helukabel-11218-jz-500-hmh-highly-flame-retardant-control-and-connection-cable","title":"20 AWG 50C Helukabel 11218 JZ-500 HMH Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11201_EN_GB_2.pdf?v=1770107340\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 50C Helukabel 11218 JZ-500 HMH Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e20 AWG 50C HMH = Halogen-free, 500 HMH, Halogen-free polymer, Flame-retardant, Low smoke density, Low corrosive gas emission, 20 AWG 50C Tool machines, Conveyor belts, Production \u0026amp; assembly lines, 20 AWG 50C Plant and factory wiring, Air-conditioning systems, Steel, rolling \u0026amp; metallurgical plants, Flexible use with occasional movement, Dry, damp, and wet areas.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363-7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• Halogen-free\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332-1-2 \/ IEC 60332-1-2\u003cbr\u003e• Bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332-3-24 \/ IEC 60332-3-24\u003cbr\u003e• Smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034-1+2 \/ IEC 61034-1+2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• Please note \"cleanroom qualification\" in your order\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size : \u003c\/b\u003e20 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²: \u003c\/b\u003e50 G 0.5\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e17.3\u003cb\u003e\u003cbr\u003e• Cu factor per km: \u003c\/b\u003e240.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 519.0\u003cbr\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63151057207665,"sku":"NNC11218","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PMLL.png?v=1770272437"},{"product_id":"20-awg-61c-helukabel-11219-jz-500-hmh-highly-flame-retardant-control-and-connection-cable","title":"20 AWG 61C Helukabel 11219 JZ-500 HMH Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11201_EN_GB_2.pdf?v=1770107340\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 61C Helukabel 11219 JZ-500 HMH Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e20 AWG 61C HMH = Halogen-free, 500 HMH, Halogen-free polymer, Flame-retardant, Low smoke density, Low corrosive gas emission, 20 AWG 61C Tool machines, Conveyor belts, Production \u0026amp; assembly lines, 20 AWG 61C Plant and factory wiring, Air-conditioning systems, Steel, rolling \u0026amp; metallurgical plants, Flexible use with occasional movement, Dry, damp, and wet areas.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363-7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• Halogen-free\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332-1-2 \/ IEC 60332-1-2\u003cbr\u003e• Bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332-3-24 \/ IEC 60332-3-24\u003cbr\u003e• Smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034-1+2 \/ IEC 61034-1+2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• Please note \"cleanroom qualification\" in your order\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size : \u003c\/b\u003e20 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²: \u003c\/b\u003e61 G 0.5\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e18.5\u003cb\u003e\u003cbr\u003e• Cu factor per km: \u003c\/b\u003e293.0 \u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 635.0\u003cbr\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63151061598577,"sku":"NNC11219","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PMLL.png?v=1770272437"},{"product_id":"20-awg-65c-helukabel-11220-jz-500-hmh-highly-flame-retardant-control-and-connection-cable","title":"20 AWG 65C Helukabel 11220 JZ-500 HMH Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11201_EN_GB_2.pdf?v=1770107340\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e20 AWG 65C Helukabel 11220 JZ-500 HMH Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e20 AWG 65C HMH = Halogen-free, 500 HMH, Halogen-free polymer, Flame-retardant, Low smoke density, Low corrosive gas emission, 20 AWG 65C Tool machines, Conveyor belts, Production \u0026amp; assembly lines, 20 AWG 65C Plant and factory wiring, Air-conditioning systems, Steel, rolling \u0026amp; metallurgical plants, Flexible use with occasional movement, Dry, damp, and wet areas.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363-7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• Halogen-free\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332-1-2 \/ IEC 60332-1-2\u003cbr\u003e• Bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332-3-24 \/ IEC 60332-3-24\u003cbr\u003e• Smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034-1+2 \/ IEC 61034-1+2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• Please note \"cleanroom qualification\" in your order\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size : \u003c\/b\u003e20 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²: \u003c\/b\u003e65 G 0.5\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e19.8\u003cb\u003e\u003cbr\u003e• Cu factor per km: \u003c\/b\u003e312.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 694.0\u003cbr\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63151064318321,"sku":"NNC11220","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PMLL.png?v=1770272437"},{"product_id":"19-awg-2c-helukabel-11221-oz-500-hmh-highly-flame-retardant-control-and-connection-cable","title":"19 AWG 2C Helukabel 11221 OZ-500 HMH Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11201_EN_GB_2.pdf?v=1770107340\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e19 AWG 2C Helukabel 11221 OZ-500 HMH Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e19 AWG 2C HMH = Halogen-free, 500 HMH, Halogen-free polymer, Flame-retardant, Low smoke density, Low corrosive gas emission, 19 AWG 2C Tool machines, Conveyor belts, Production \u0026amp; assembly lines, 19 AWG 2C Plant and factory wiring, Air-conditioning systems, Steel, rolling \u0026amp; metallurgical plants, Flexible use with occasional movement, Dry, damp, and wet areas.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363-7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• Halogen-free\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332-1-2 \/ IEC 60332-1-2\u003cbr\u003e• Bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332-3-24 \/ IEC 60332-3-24\u003cbr\u003e• Smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034-1+2 \/ IEC 61034-1+2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• Please note \"cleanroom qualification\" in your order\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size : \u003c\/b\u003e19 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²: \u003c\/b\u003e2 x 0.75\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e5.3\u003cb\u003e\u003cbr\u003e• Cu factor per km: \u003c\/b\u003e14.4\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 47.0\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63151074935153,"sku":"NNC11221","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PML_9bda7729-bb22-48e1-b277-f0ed545bc5d3.png?v=1770280031"},{"product_id":"19-awg-3c-helukabel-11222-jz-500-hmh-highly-flame-retardant-control-and-connection-cable","title":"19 AWG 3C Helukabel 11222 JZ-500 HMH Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11201_EN_GB_2.pdf?v=1770107340\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e19 AWG 3C Helukabel 11222 JZ-500 HMH Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e19 AWG 3C HMH = Halogen-free, 500 HMH, Halogen-free polymer, Flame-retardant, Low smoke density, Low corrosive gas emission, 19 AWG 3C Tool machines, Conveyor belts, Production \u0026amp; assembly lines, 19 AWG 3C Plant and factory wiring, Air-conditioning systems, Steel, rolling \u0026amp; metallurgical plants, Flexible use with occasional movement, Dry, damp, and wet areas.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363-7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• Halogen-free\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332-1-2 \/ IEC 60332-1-2\u003cbr\u003e• Bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332-3-24 \/ IEC 60332-3-24\u003cbr\u003e• Smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034-1+2 \/ IEC 61034-1+2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• Please note \"cleanroom qualification\" in your order\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size : \u003c\/b\u003e19 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²: \u003c\/b\u003e3 G 0.75\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e5.6\u003cb\u003e\u003cbr\u003e• Cu factor per km: \u003c\/b\u003e21.6\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 56.0\u003cbr\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63151080604017,"sku":"NNC11222","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PMLL_132b6a72-a241-46fc-968d-1d7dffe338ad.png?v=1770280556"},{"product_id":"19-awg-3c-helukabel-11335-oz-500-hmh-highly-flame-retardant-control-and-connection-cable","title":"19 AWG 3C Helukabel 11335 OZ-500 HMH Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11201_EN_GB_2.pdf?v=1770107340\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e19 AWG 3C Helukabel 11335 OZ-500 HMH Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e19 AWG 3C HMH = Halogen-free, 500 HMH, Halogen-free polymer, Flame-retardant, Low smoke density, Low corrosive gas emission, 19 AWG 3C Tool machines, Conveyor belts, Production \u0026amp; assembly lines, 19 AWG 3C Plant and factory wiring, Air-conditioning systems, Steel, rolling \u0026amp; metallurgical plants, Flexible use with occasional movement, Dry, damp, and wet areas.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363-7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• Halogen-free\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332-1-2 \/ IEC 60332-1-2\u003cbr\u003e• Bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332-3-24 \/ IEC 60332-3-24\u003cbr\u003e• Smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034-1+2 \/ IEC 61034-1+2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• Please note \"cleanroom qualification\" in your order\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size : \u003c\/b\u003e19 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²: \u003c\/b\u003e3 x 0.75\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e5.6\u003cb\u003e\u003cbr\u003e• Cu factor per km: \u003c\/b\u003e21.6\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 56.0\u003cbr\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63151146959217,"sku":"NNC11335","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PML_d8ca3add-6a44-4d59-98c3-23dc803ca0f8.png?v=1770284488"},{"product_id":"19-awg-4c-helukabel-11223-jz-500-hmh-highly-flame-retardant-control-and-connection-cable","title":"19 AWG 4C Helukabel 11223 JZ-500 HMH Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11201_EN_GB_2.pdf?v=1770107340\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e19 AWG 4C Helukabel 11223 JZ-500 HMH Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e19 AWG 4C HMH = Halogen-free, 500 HMH, Halogen-free polymer, Flame-retardant, Low smoke density, Low corrosive gas emission, 19 AWG 4C Tool machines, Conveyor belts, Production \u0026amp; assembly lines, 19 AWG 4C Plant and factory wiring, Air-conditioning systems, Steel, rolling \u0026amp; metallurgical plants, Flexible use with occasional movement, Dry, damp, and wet areas.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363-7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• Halogen-free\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332-1-2 \/ IEC 60332-1-2\u003cbr\u003e• Bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332-3-24 \/ IEC 60332-3-24\u003cbr\u003e• Smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034-1+2 \/ IEC 61034-1+2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• Please note \"cleanroom qualification\" in your order\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size : \u003c\/b\u003e19 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²: \u003c\/b\u003e4 G 0.75\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e6.3\u003cb\u003e\u003cbr\u003e• Cu factor per km: \u003c\/b\u003e29.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 69.0\u003cbr\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63151150104945,"sku":"NNC11223","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PMLL_e1c9e06b-8ccb-46ae-8c36-e75d1088faf7.png?v=1770284690"},{"product_id":"19-awg-4c-helukabel-11336-oz-500-hmh-highly-flame-retardant-control-and-connection-cable","title":"19 AWG 4C Helukabel 11336 OZ-500 HMH Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11201_EN_GB_2.pdf?v=1770107340\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e19 AWG 4C Helukabel 11336 OZ-500 HMH Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e19 AWG 4C HMH = Halogen-free, 500 HMH, Halogen-free polymer, Flame-retardant, Low smoke density, Low corrosive gas emission, 19 AWG 4C Tool machines, Conveyor belts, Production \u0026amp; assembly lines, 19 AWG 4C Plant and factory wiring, Air-conditioning systems, Steel, rolling \u0026amp; metallurgical plants, Flexible use with occasional movement, Dry, damp, and wet areas.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363-7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• Halogen-free\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332-1-2 \/ IEC 60332-1-2\u003cbr\u003e• Bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332-3-24 \/ IEC 60332-3-24\u003cbr\u003e• Smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034-1+2 \/ IEC 61034-1+2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• Please note \"cleanroom qualification\" in your order\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size : \u003c\/b\u003e19 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²: \u003c\/b\u003e4 x 0.75 \u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e6.3\u003cb\u003e\u003cbr\u003e• Cu factor per km: \u003c\/b\u003e29.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 69.0\u003cbr\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63151150727537,"sku":"NNC11336","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PML_d8ca3add-6a44-4d59-98c3-23dc803ca0f8.png?v=1770284488"},{"product_id":"19-awg-5c-helukabel-11224-jz-500-hmh-highly-flame-retardant-control-and-connection-cable","title":"19 AWG 5C Helukabel 11224 JZ-500 HMH Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11201_EN_GB_2.pdf?v=1770107340\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e19 AWG 5C Helukabel 11224 JZ-500 HMH Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e19 AWG 5C HMH = Halogen-free, 500 HMH, Halogen-free polymer, Flame-retardant, Low smoke density, Low corrosive gas emission, 19 AWG 5C Tool machines, Conveyor belts, Production \u0026amp; assembly lines, 19 AWG 5C Plant and factory wiring, Air-conditioning systems, Steel, rolling \u0026amp; metallurgical plants, Flexible use with occasional movement, Dry, damp, and wet areas.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363-7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• Halogen-free\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332-1-2 \/ IEC 60332-1-2\u003cbr\u003e• Bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332-3-24 \/ IEC 60332-3-24\u003cbr\u003e• Smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034-1+2 \/ IEC 61034-1+2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• Please note \"cleanroom qualification\" in your order\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size : \u003c\/b\u003e19 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²: \u003c\/b\u003e5 G 0.75\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e6.9\u003cb\u003e\u003cbr\u003e• Cu factor per km: \u003c\/b\u003e36.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 83.0\u003cbr\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63151162917233,"sku":"NNC11224","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PMLL_e1c9e06b-8ccb-46ae-8c36-e75d1088faf7.png?v=1770284690"},{"product_id":"19-awg-5c-helukabel-11337-oz-500-hmh-highly-flame-retardant-control-and-connection-cable","title":"19 AWG 5C Helukabel 11337 OZ-500 HMH Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11201_EN_GB_2.pdf?v=1770107340\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e19 AWG 5C Helukabel 11337 OZ-500 HMH Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e19 AWG 5C HMH = Halogen-free, 500 HMH, Halogen-free polymer, Flame-retardant, Low smoke density, Low corrosive gas emission, 19 AWG 5C Tool machines, Conveyor belts, Production \u0026amp; assembly lines, 19 AWG 5C Plant and factory wiring, Air-conditioning systems, Steel, rolling \u0026amp; metallurgical plants, Flexible use with occasional movement, Dry, damp, and wet areas.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363-7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• Halogen-free\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332-1-2 \/ IEC 60332-1-2\u003cbr\u003e• Bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332-3-24 \/ IEC 60332-3-24\u003cbr\u003e• Smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034-1+2 \/ IEC 61034-1+2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• Please note \"cleanroom qualification\" in your order\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size : \u003c\/b\u003e19 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²: \u003c\/b\u003e5 x 0.75 \u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e6.9\u003cb\u003e\u003cbr\u003e• Cu factor per km: \u003c\/b\u003e36.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 83.0\u003cbr\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63151172551025,"sku":"NNC11337","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PML_d8ca3add-6a44-4d59-98c3-23dc803ca0f8.png?v=1770284488"},{"product_id":"19-awg-7c-helukabel-11225-jz-500-hmh-highly-flame-retardant-control-and-connection-cable","title":"19 AWG 7C Helukabel 11225 JZ-500 HMH Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11201_EN_GB_2.pdf?v=1770107340\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e19 AWG 7C Helukabel 11225 JZ-500 HMH Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e19 AWG 7C HMH = Halogen-free, 500 HMH, Halogen-free polymer, Flame-retardant, Low smoke density, Low corrosive gas emission, 19 AWG 7C Tool machines, Conveyor belts, Production \u0026amp; assembly lines, 19 AWG 7C Plant and factory wiring, Air-conditioning systems, Steel, rolling \u0026amp; metallurgical plants, Flexible use with occasional movement, Dry, damp, and wet areas.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363-7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• Halogen-free\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332-1-2 \/ IEC 60332-1-2\u003cbr\u003e• Bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332-3-24 \/ IEC 60332-3-24\u003cbr\u003e• Smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034-1+2 \/ IEC 61034-1+2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• Please note \"cleanroom qualification\" in your order\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size : \u003c\/b\u003e19 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²: \u003c\/b\u003e7 G 0.75\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e7.7\u003cb\u003e\u003cbr\u003e• Cu factor per km: \u003c\/b\u003e50.0 \u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 114.0\u003cbr\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63151203975537,"sku":"NNC11225","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PMLL_756d5663-efb4-4e0e-a381-b882a7a05b02.png?v=1770288415"},{"product_id":"19-awg-7c-helukabel-11338-oz-500-hmh-highly-flame-retardant-control-and-connection-cable","title":"19 AWG 7C Helukabel 11338 OZ-500 HMH Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11201_EN_GB_2.pdf?v=1770107340\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e19 AWG 7C Helukabel 11338 OZ-500 HMH Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e19 AWG 7C HMH = Halogen-free, 500 HMH, Halogen-free polymer, Flame-retardant, Low smoke density, Low corrosive gas emission, 19 AWG 7C Tool machines, Conveyor belts, Production \u0026amp; assembly lines, 19 AWG 7C Plant and factory wiring, Air-conditioning systems, Steel, rolling \u0026amp; metallurgical plants, Flexible use with occasional movement, Dry, damp, and wet areas.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363-7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• Halogen-free\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332-1-2 \/ IEC 60332-1-2\u003cbr\u003e• Bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332-3-24 \/ IEC 60332-3-24\u003cbr\u003e• Smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034-1+2 \/ IEC 61034-1+2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• Please note \"cleanroom qualification\" in your order\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size : \u003c\/b\u003e19 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²: \u003c\/b\u003e7 x 0.75\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e7.7\u003cb\u003e\u003cbr\u003e• Cu factor per km: \u003c\/b\u003e50.0 \u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 114.0\u003cbr\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63151215509873,"sku":"NNC11338","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PML_c1c98c12-da3e-422e-9975-2f1822a636c2.png?v=1770288613"},{"product_id":"19-awg-8c-helukabel-11226-jz-500-hmh-highly-flame-retardant-control-and-connection-cable","title":"19 AWG 8C Helukabel 11226 JZ-500 HMH Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11201_EN_GB_2.pdf?v=1770107340\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e19 AWG 8C Helukabel 11226 JZ-500 HMH Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e19 AWG 8C HMH = Halogen-free, 500 HMH, Halogen-free polymer, Flame-retardant, Low smoke density, Low corrosive gas emission, 19 AWG 8C Tool machines, Conveyor belts, Production \u0026amp; assembly lines, 19 AWG 8C Plant and factory wiring, Air-conditioning systems, Steel, rolling \u0026amp; metallurgical plants, Flexible use with occasional movement, Dry, damp, and wet areas.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363-7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• Halogen-free\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332-1-2 \/ IEC 60332-1-2\u003cbr\u003e• Bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332-3-24 \/ IEC 60332-3-24\u003cbr\u003e• Smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034-1+2 \/ IEC 61034-1+2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• Please note \"cleanroom qualification\" in your order\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size : \u003c\/b\u003e19 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²: \u003c\/b\u003e8 G 0.75\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e8.3\u003cb\u003e\u003cbr\u003e• Cu factor per km: \u003c\/b\u003e58.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 136.0\u003cbr\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63151224455537,"sku":"NNC11226","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PMLL_b963d259-2207-45fb-8835-03a8a36221b9.png?v=1770289061"},{"product_id":"19-awg-10c-helukabel-11227-jz-500-hmh-highly-flame-retardant-control-and-connection-cable","title":"19 AWG 10C Helukabel 11227 JZ-500 HMH Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11201_EN_GB_2.pdf?v=1770107340\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e19 AWG 10C Helukabel 11227 JZ-500 HMH Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e19 AWG 10C HMH = Halogen-free, 500 HMH, Halogen-free polymer, Flame-retardant, Low smoke density, Low corrosive gas emission, 19 AWG 10C Tool machines, Conveyor belts, Production \u0026amp; assembly lines, 19 AWG 10C Plant and factory wiring, Air-conditioning systems, Steel, rolling \u0026amp; metallurgical plants, Flexible use with occasional movement, Dry, damp, and wet areas.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363-7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• Halogen-free\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332-1-2 \/ IEC 60332-1-2\u003cbr\u003e• Bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332-3-24 \/ IEC 60332-3-24\u003cbr\u003e• Smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034-1+2 \/ IEC 61034-1+2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• Please note \"cleanroom qualification\" in your order\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size : \u003c\/b\u003e19 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²: \u003c\/b\u003e10 G 0.75\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e9.8\u003cb\u003e\u003cbr\u003e• Cu factor per km: \u003c\/b\u003e72.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 172.0\u003cbr\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63151240774001,"sku":"NNC11227","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PMLL_b963d259-2207-45fb-8835-03a8a36221b9.png?v=1770289061"},{"product_id":"19-awg-12c-helukabel-11228-jz-500-hmh-highly-flame-retardant-control-and-connection-cable","title":"19 AWG 12C Helukabel 11228 JZ-500 HMH Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11201_EN_GB_2.pdf?v=1770107340\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e19 AWG 12C Helukabel 11228 JZ-500 HMH Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e19 AWG 12C HMH = Halogen-free, 500 HMH, Halogen-free polymer, Flame-retardant, Low smoke density, Low corrosive gas emission, 19 AWG 12C Tool machines, Conveyor belts, Production \u0026amp; assembly lines, 19 AWG 12C Plant and factory wiring, Air-conditioning systems, Steel, rolling \u0026amp; metallurgical plants, Flexible use with occasional movement, Dry, damp, and wet areas.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363-7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• Halogen-free\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332-1-2 \/ IEC 60332-1-2\u003cbr\u003e• Bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332-3-24 \/ IEC 60332-3-24\u003cbr\u003e• Smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034-1+2 \/ IEC 61034-1+2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• Please note \"cleanroom qualification\" in your order\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size : \u003c\/b\u003e19 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²: \u003c\/b\u003e12 G 0.75\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e10.1\u003cb\u003e\u003cbr\u003e• Cu factor per km: \u003c\/b\u003e86.0 \u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 183.0\u003cbr\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63153028956529,"sku":"NNC11228","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PMLL_b963d259-2207-45fb-8835-03a8a36221b9.png?v=1770289061"},{"product_id":"19-awg-16c-helukabel-11229-jz-500-hmh-highly-flame-retardant-control-and-connection-cable","title":"19 AWG 16C Helukabel 11229 JZ-500 HMH Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11201_EN_GB_2.pdf?v=1770107340\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e19 AWG 16C Helukabel 11229 JZ-500 HMH Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e19 AWG 16C HMH = Halogen-free, 500 HMH, Halogen-free polymer, Flame-retardant, Low smoke density, Low corrosive gas emission, 19 AWG 16C Tool machines, Conveyor belts, Production \u0026amp; assembly lines, 19 AWG 16C Plant and factory wiring, Air-conditioning systems, Steel, rolling \u0026amp; metallurgical plants, Flexible use with occasional movement, Dry, damp, and wet areas.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363-7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• Halogen-free\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332-1-2 \/ IEC 60332-1-2\u003cbr\u003e• Bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332-3-24 \/ IEC 60332-3-24\u003cbr\u003e• Smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034-1+2 \/ IEC 61034-1+2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• Please note \"cleanroom qualification\" in your order\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size : \u003c\/b\u003e19 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²: \u003c\/b\u003e16 G 0.75\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e11.4\u003cb\u003e\u003cbr\u003e• Cu factor per km: \u003c\/b\u003e115.0\u003cb\u003e \u003c\/b\u003e \u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 241.0\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63153036657009,"sku":"NNC11229","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PMLL_b963d259-2207-45fb-8835-03a8a36221b9.png?v=1770289061"},{"product_id":"19-awg-18c-helukabel-11230-jz-500-hmh-highly-flame-retardant-control-and-connection-cable","title":"19 AWG 18C Helukabel 11230 JZ-500 HMH Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11201_EN_GB_2.pdf?v=1770107340\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e19 AWG 18C Helukabel 11230 JZ-500 HMH Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e19 AWG 18C HMH = Halogen-free, 500 HMH, Halogen-free polymer, Flame-retardant, Low smoke density, Low corrosive gas emission, 19 AWG 18C Tool machines, Conveyor belts, Production \u0026amp; assembly lines, 19 AWG 18C Plant and factory wiring, Air-conditioning systems, Steel, rolling \u0026amp; metallurgical plants, Flexible use with occasional movement, Dry, damp, and wet areas.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363-7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• Halogen-free\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332-1-2 \/ IEC 60332-1-2\u003cbr\u003e• Bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332-3-24 \/ IEC 60332-3-24\u003cbr\u003e• Smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034-1+2 \/ IEC 61034-1+2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• Please note \"cleanroom qualification\" in your order\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size : \u003c\/b\u003e19 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²: \u003c\/b\u003e18 G 0.75\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e12.2\u003cb\u003e\u003cbr\u003e• Cu factor per km: \u003c\/b\u003e130.0  \u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 266.0\u003cbr\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63153037443441,"sku":"NNC11230","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PMLL_b963d259-2207-45fb-8835-03a8a36221b9.png?v=1770289061"},{"product_id":"19-awg-20c-helukabel-11231-jz-500-hmh-highly-flame-retardant-control-and-connection-cable","title":"19 AWG 20C Helukabel 11231 JZ-500 HMH Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11201_EN_GB_2.pdf?v=1770107340\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e19 AWG 20C Helukabel 11231 JZ-500 HMH Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e19 AWG 20C HMH = Halogen-free, 500 HMH, Halogen-free polymer, Flame-retardant, Low smoke density, Low corrosive gas emission, 19 AWG 20C Tool machines, Conveyor belts, Production \u0026amp; assembly lines, 19 AWG 20C Plant and factory wiring, Air-conditioning systems, Steel, rolling \u0026amp; metallurgical plants, Flexible use with occasional movement, Dry, damp, and wet areas.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363-7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• Halogen-free\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332-1-2 \/ IEC 60332-1-2\u003cbr\u003e• Bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332-3-24 \/ IEC 60332-3-24\u003cbr\u003e• Smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034-1+2 \/ IEC 61034-1+2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• Please note \"cleanroom qualification\" in your order\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size : \u003c\/b\u003e19 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²: \u003c\/b\u003e20 G 0.75\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e12.8 \u003cb\u003e\u003cbr\u003e• Cu factor per km: \u003c\/b\u003e144.0 \u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 291.0\u003cbr\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63153043571057,"sku":"NNC11231","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PMLL_b963d259-2207-45fb-8835-03a8a36221b9.png?v=1770289061"},{"product_id":"19-awg-25c-helukabel-11232-jz-500-hmh-highly-flame-retardant-control-and-connection-cable","title":"19 AWG 25C Helukabel 11232 JZ-500 HMH Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11201_EN_GB_2.pdf?v=1770107340\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e19 AWG 25C Helukabel 11232 JZ-500 HMH Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e19 AWG 25C HMH = Halogen-free, 500 HMH, Halogen-free polymer, Flame-retardant, Low smoke density, Low corrosive gas emission, 19 AWG 25C Tool machines, Conveyor belts, Production \u0026amp; assembly lines, 19 AWG 25C Plant and factory wiring, Air-conditioning systems, Steel, rolling \u0026amp; metallurgical plants, Flexible use with occasional movement, Dry, damp, and wet areas.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363-7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• Halogen-free\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332-1-2 \/ IEC 60332-1-2\u003cbr\u003e• Bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332-3-24 \/ IEC 60332-3-24\u003cbr\u003e• Smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034-1+2 \/ IEC 61034-1+2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• Please note \"cleanroom qualification\" in your order\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size : \u003c\/b\u003e19 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²: \u003c\/b\u003e25 G 0.75\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx: \u003c\/b\u003e14.3\u003cb\u003e\u003cbr\u003e• Cu factor per km: \u003c\/b\u003e180.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 374.0\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63153044619633,"sku":"NNC11232","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PMLL_b963d259-2207-45fb-8835-03a8a36221b9.png?v=1770289061"},{"product_id":"19-awg-30c-helukabel-11233-jz-500-hmh-highly-flame-retardant-control-and-connection-cable","title":"19 AWG 30C Helukabel 11233 JZ-500 HMH Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11201_EN_GB_2.pdf?v=1770107340\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e19 AWG 30C Helukabel 11233 JZ-500 HMH Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e19 AWG 30C HMH = Halogen-free, 500 HMH, Halogen-free polymer, Flame-retardant, Low smoke density, Low corrosive gas emission, 19 AWG 30C Tool machines, Conveyor belts, Production \u0026amp; assembly lines, 19 AWG 30C Plant and factory wiring, Air-conditioning systems, Steel, rolling \u0026amp; metallurgical plants, Flexible use with occasional movement, Dry, damp, and wet areas.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363-7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• Halogen-free\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332-1-2 \/ IEC 60332-1-2\u003cbr\u003e• Bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332-3-24 \/ IEC 60332-3-24\u003cbr\u003e• Smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034-1+2 \/ IEC 61034-1+2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• Please note \"cleanroom qualification\" in your order\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size : \u003c\/b\u003e19 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²: \u003c\/b\u003e30 G 0.75\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx:\u003c\/b\u003e 15.3\u003cb\u003e\u003cbr\u003e• Cu factor per km: \u003c\/b\u003e216.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 450.0\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63153046847857,"sku":"NNC11233","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PMLL_b963d259-2207-45fb-8835-03a8a36221b9.png?v=1770289061"},{"product_id":"19-awg-34c-helukabel-11234-jz-500-hmh-highly-flame-retardant-control-and-connection-cable","title":"19 AWG 34C Helukabel 11234 JZ-500 HMH Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11201_EN_GB_2.pdf?v=1770107340\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e19 AWG 34C Helukabel 11234 JZ-500 HMH Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e19 AWG 34C HMH = Halogen-free, 500 HMH, Halogen-free polymer, Flame-retardant, Low smoke density, Low corrosive gas emission, 19 AWG 34C Tool machines, Conveyor belts, Production \u0026amp; assembly lines, 19 AWG 34C Plant and factory wiring, Air-conditioning systems, Steel, rolling \u0026amp; metallurgical plants, Flexible use with occasional movement, Dry, damp, and wet areas.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363-7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• Halogen-free\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332-1-2 \/ IEC 60332-1-2\u003cbr\u003e• Bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332-3-24 \/ IEC 60332-3-24\u003cbr\u003e• Smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034-1+2 \/ IEC 61034-1+2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• Please note \"cleanroom qualification\" in your order\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size : \u003c\/b\u003e19 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²: \u003c\/b\u003e34 G 0.75\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx:\u003c\/b\u003e 16.7 \u003cb\u003e\u003cbr\u003e• Cu factor per km: \u003c\/b\u003e245.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 517.0\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63153047634289,"sku":"NNC11234","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PMLL_b963d259-2207-45fb-8835-03a8a36221b9.png?v=1770289061"},{"product_id":"19-awg-37c-helukabel-11235-jz-500-hmh-highly-flame-retardant-control-and-connection-cable","title":"19 AWG 37C Helukabel 11235 JZ-500 HMH Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11201_EN_GB_2.pdf?v=1770107340\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e19 AWG 37C Helukabel 11235 JZ-500 HMH Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e19 AWG 37C HMH = Halogen-free, 500 HMH, Halogen-free polymer, Flame-retardant, Low smoke density, Low corrosive gas emission, 19 AWG 37C Tool machines, Conveyor belts, Production \u0026amp; assembly lines, 19 AWG 37C Plant and factory wiring, Air-conditioning systems, Steel, rolling \u0026amp; metallurgical plants, Flexible use with occasional movement, Dry, damp, and wet areas.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363-7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• Halogen-free\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332-1-2 \/ IEC 60332-1-2\u003cbr\u003e• Bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332-3-24 \/ IEC 60332-3-24\u003cbr\u003e• Smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034-1+2 \/ IEC 61034-1+2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• Please note \"cleanroom qualification\" in your order\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size : \u003c\/b\u003e19 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²: \u003c\/b\u003e37 G 0.75\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx:\u003c\/b\u003e 16.7 \u003cb\u003e\u003cbr\u003e• Cu factor per km: \u003c\/b\u003e260.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 541.0\u003cbr\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63153050943857,"sku":"NNC11235","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PMLL_b963d259-2207-45fb-8835-03a8a36221b9.png?v=1770289061"},{"product_id":"19-awg-41c-helukabel-11236-jz-500-hmh-highly-flame-retardant-control-and-connection-cable","title":"19 AWG 41C Helukabel 11236 JZ-500 HMH Highly flame retardant Control and Connection Cable)","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11201_EN_GB_2.pdf?v=1770107340\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e19 AWG 41C Helukabel 11236 JZ-500 HMH Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e19 AWG 41C HMH = Halogen-free, 500 HMH, Halogen-free polymer, Flame-retardant, Low smoke density, Low corrosive gas emission, 19 AWG 41C Tool machines, Conveyor belts, Production \u0026amp; assembly lines, 19 AWG 41C Plant and factory wiring, Air-conditioning systems, Steel, rolling \u0026amp; metallurgical plants, Flexible use with occasional movement, Dry, damp, and wet areas.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363-7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• Halogen-free\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332-1-2 \/ IEC 60332-1-2\u003cbr\u003e• Bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332-3-24 \/ IEC 60332-3-24\u003cbr\u003e• Smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034-1+2 \/ IEC 61034-1+2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• Please note \"cleanroom qualification\" in your order\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size : \u003c\/b\u003e19 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²: \u003c\/b\u003e41 G 0.75\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx:\u003c\/b\u003e 18.2\u003cb\u003e\u003cbr\u003e• Cu factor per km: \u003c\/b\u003e296.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 611.0\u003cbr\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63153054155121,"sku":"NNC11236","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PMLL_b963d259-2207-45fb-8835-03a8a36221b9.png?v=1770289061"},{"product_id":"19-awg-42c-helukabel-11237-jz-500-hmh-highly-flame-retardant-control-and-connection-cable","title":"19 AWG 42C Helukabel 11237 JZ-500 HMH Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11201_EN_GB_2.pdf?v=1770107340\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e19 AWG 42C Helukabel 11237 JZ-500 HMH Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e19 AWG 42C HMH = Halogen-free, 500 HMH, Halogen-free polymer, Flame-retardant, Low smoke density, Low corrosive gas emission, 19 AWG 42C Tool machines, Conveyor belts, Production \u0026amp; assembly lines, 19 AWG 42C Plant and factory wiring, Air-conditioning systems, Steel, rolling \u0026amp; metallurgical plants, Flexible use with occasional movement, Dry, damp, and wet areas.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363-7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• Halogen-free\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332-1-2 \/ IEC 60332-1-2\u003cbr\u003e• Bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332-3-24 \/ IEC 60332-3-24\u003cbr\u003e• Smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034-1+2 \/ IEC 61034-1+2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• Please note \"cleanroom qualification\" in your order\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size : \u003c\/b\u003e19 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²: \u003c\/b\u003e42 G 0.75\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx:\u003c\/b\u003e 18.2\u003cb\u003e\u003cbr\u003e• Cu factor per km: \u003c\/b\u003e302.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 621.0\u003cbr\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63153054450033,"sku":"NNC11237","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PMLL_b963d259-2207-45fb-8835-03a8a36221b9.png?v=1770289061"},{"product_id":"19-awg-50c-helukabel-11238-jz-500-hmh-highly-flame-retardant-control-and-connection-cable","title":"19 AWG 50C Helukabel 11238 JZ-500 HMH Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11201_EN_GB_2.pdf?v=1770107340\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e19 AWG 50C Helukabel 11238 JZ-500 HMH Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e19 AWG 50C HMH = Halogen-free, 500 HMH, Halogen-free polymer, Flame-retardant, Low smoke density, Low corrosive gas emission, 19 AWG 50C Tool machines, Conveyor belts, Production \u0026amp; assembly lines, 19 AWG 50C Plant and factory wiring, Air-conditioning systems, Steel, rolling \u0026amp; metallurgical plants, Flexible use with occasional movement, Dry, damp, and wet areas.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363-7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• Halogen-free\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332-1-2 \/ IEC 60332-1-2\u003cbr\u003e• Bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332-3-24 \/ IEC 60332-3-24\u003cbr\u003e• Smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034-1+2 \/ IEC 61034-1+2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• Please note \"cleanroom qualification\" in your order\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size : \u003c\/b\u003e19 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²: \u003c\/b\u003e50 G 0.75\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx:\u003c\/b\u003e 19.8\u003cb\u003e\u003cbr\u003e• Cu factor per km: \u003c\/b\u003e360.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 742.0\u003cbr\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63153055203697,"sku":"NNC11238","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PMLL_b963d259-2207-45fb-8835-03a8a36221b9.png?v=1770289061"},{"product_id":"19-awg-61c-helukabel-11239-jz-500-hmh-highly-flame-retardant-control-and-connection-cable","title":"19 AWG 61C Helukabel 11239 JZ-500 HMH Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11201_EN_GB_2.pdf?v=1770107340\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e19 AWG 61C Helukabel 11239 JZ-500 HMH Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e19 AWG 61C HMH = Halogen-free, 500 HMH, Halogen-free polymer, Flame-retardant, Low smoke density, Low corrosive gas emission, 19 AWG 61C Tool machines, Conveyor belts, Production \u0026amp; assembly lines, 19 AWG 61C Plant and factory wiring, Air-conditioning systems, Steel, rolling \u0026amp; metallurgical plants, Flexible use with occasional movement, Dry, damp, and wet areas.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363-7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• Halogen-free\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332-1-2 \/ IEC 60332-1-2\u003cbr\u003e• Bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332-3-24 \/ IEC 60332-3-24\u003cbr\u003e• Smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034-1+2 \/ IEC 61034-1+2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• Please note \"cleanroom qualification\" in your order\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size : \u003c\/b\u003e19 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²: \u003c\/b\u003e61 G 0.75\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx:\u003c\/b\u003e 21.2\u003cb\u003e\u003cbr\u003e• Cu factor per km: \u003c\/b\u003e439.0\u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 853.0\u003cbr\u003e\u003cbr\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63153056350577,"sku":"NNC11239","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PMLL_b963d259-2207-45fb-8835-03a8a36221b9.png?v=1770289061"},{"product_id":"19-awg-65c-helukabel-11240-jz-500-hmh-highly-flame-retardant-control-and-connection-cable","title":"19 AWG 65C Helukabel 11240 JZ-500 HMH Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11201_EN_GB_2.pdf?v=1770107340\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e19 AWG 65C Helukabel 11240 JZ-500 HMH Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e19 AWG 65C HMH = Halogen-free, 500 HMH, Halogen-free polymer, Flame-retardant, Low smoke density, Low corrosive gas emission, 19 AWG 65C Tool machines, Conveyor belts, Production \u0026amp; assembly lines, 19 AWG 65C Plant and factory wiring, Air-conditioning systems, Steel, rolling \u0026amp; metallurgical plants, Flexible use with occasional movement, Dry, damp, and wet areas.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363-7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• Halogen-free\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332-1-2 \/ IEC 60332-1-2\u003cbr\u003e• Bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332-3-24 \/ IEC 60332-3-24\u003cbr\u003e• Smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034-1+2 \/ IEC 61034-1+2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• Please note \"cleanroom qualification\" in your order\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size : \u003c\/b\u003e19 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²: \u003c\/b\u003e65 G 0.75\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx:\u003c\/b\u003e 22.6\u003cb\u003e\u003cbr\u003e• Cu factor per km: \u003c\/b\u003e468.0 \u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 909.0\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63153056842097,"sku":"NNC11240","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PMLL_b963d259-2207-45fb-8835-03a8a36221b9.png?v=1770289061"},{"product_id":"19-awg-100c-helukabel-11017876-jz-500-hmh-highly-flame-retardant-control-and-connection-cable","title":"19 AWG 100C Helukabel 11017876 JZ-500 HMH Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11201_EN_GB_2.pdf?v=1770107340\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e19 AWG 100C Helukabel 11017876 JZ-500 HMH Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e19 AWG 100C HMH = Halogen-free, 500 HMH, Halogen-free polymer, Flame-retardant, Low smoke density, Low corrosive gas emission, 19 AWG 100C Tool machines, Conveyor belts, Production \u0026amp; assembly lines, 19 AWG 100C Plant and factory wiring, Air conditioning systems, Steel, rolling \u0026amp; metallurgical plants, Flexible use with occasional movement, Dry, damp, and wet areas.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363-7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• Halogen-free\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332-1-2 \/ IEC 60332-1-2\u003cbr\u003e• Bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332-3-24 \/ IEC 60332-3-24\u003cbr\u003e• Smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034-1+2 \/ IEC 61034-1+2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• Please note \"cleanroom qualification\" in your order\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size : \u003c\/b\u003e19 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²: \u003c\/b\u003e100 G 0.75\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx:\u003c\/b\u003e 27.5\u003cb\u003e\u003cbr\u003e• Cu factor per km: \u003c\/b\u003e720.0 \u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 1220.0\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63153057038705,"sku":"NNC11017876","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PMLL_b963d259-2207-45fb-8835-03a8a36221b9.png?v=1770289061"},{"product_id":"18-awg-2c-helukabel-11241-oz-500-hmh-highly-flame-retardant-control-and-connection-cable","title":"18 AWG 2C Helukabel 11241 OZ-500 HMH Highly flame retardant Control and Connection Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/HELUKABEL_M11201_EN_GB_2.pdf?v=1770107340\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-sheets-root=\"1\"\u003e18 AWG 2C Helukabel 11241 OZ-500 HMH Highly flame retardant Control and Connection Cable\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003eControl und connection cable in tool machinery, conveyor belts, production lines, plant construction, in air-conditioning devices, in metallurgical, steel and rolling mills. For fixed installation and flexible applications with occasional, not constantly recurring free movement without forced motion, without tensile stress and for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e18 AWG 2C HMH = Halogen-free, 500 HMH, Halogen-free polymer, Flame-retardant, Low smoke density, Low corrosive gas emission, 18 AWG 2C Tool machines, Conveyor belts, Production \u0026amp; assembly lines, 18 AWG 2C Plant and factory wiring, Air conditioning systems, Steel, rolling \u0026amp; metallurgical plants, Flexible use with occasional movement, Dry, damp, and wet areas.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data:\u003c\/h3\u003e\n\u003cp\u003eControl and connection cable in alignment with DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, DIN VDE 0285-525-3- 11 \/ DIN EN 50525-3-11\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003cbr\u003e\u003c\/strong\u003eflexible -25°C to +70°C\u003cbr\u003efixed -40°C to +70°C\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003eAC U0\/U 300\/500 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage core\/core\u003cbr\u003e\u003c\/strong\u003e4000 V\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003cbr\u003e\u003c\/strong\u003eflexible 12.5x Outer-Ø\u003cbr\u003efixed 4x Outer-Ø\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCable Structure:\u003c\/h3\u003e\n\u003cp\u003e• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 \/ IEC 60228 Class 5\u003cbr\u003e• Core insulation: halogen-free polymer acc. to DIN VDE 0207-363-7 \/ DIN EN 50363-7 (compound type TI6)\u003cbr\u003e• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits\u003cbr\u003e• Protective conductor: starting with 3 cores,\u003cbr\u003eG = with protective conductor GN-YE, in the outer layer (JZ),\u003cbr\u003ex = without protective conductor (OZ)\u003cbr\u003e• Cores stranded in layers with optimal lay lengths\u003cbr\u003e• Outer sheath: halogen-free polymer acc. to DIN VDE 0207-363-8 \/ DIN EN 50363-8 (compound type TM7)\u003cbr\u003e• Sheath colour: grey (RAL 7001)\u003cbr\u003e• Length marking: in metres\u003c\/p\u003e\n\u003ch3\u003eProperties:\u003c\/h3\u003e\n\u003cp\u003e• Largely resistant to: oil\u003cbr\u003e• Halogen-free\u003cbr\u003e• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eTests:\u003c\/h3\u003e\n\u003cp\u003e• Halogen-free acc. to DIN VDE 0482-754-1 \/ DIN EN 60754-1 \/ IEC 60754-1\u003cbr\u003e• Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 \/ DIN EN 60754-2 \/ IEC 60754-2\u003cbr\u003e• Flame-retardant acc. to DIN VDE 0482-332-1-2 \/ DIN EN 60332-1-2 \/ IEC 60332-1-2\u003cbr\u003e• Bundle fire test acc. to DIN VDE 0482-332-3-24 \/ DIN EN 60332-3-24 \/ IEC 60332-3-24\u003cbr\u003e• Smoke density acc. to DIN VDE 0482-1034-1+2 \/ DIN EN 61034-1+2 \/ IEC 61034-1+2\u003cbr\u003e• Certifications and approvals: EAC\u003c\/p\u003e\n\u003ch3\u003eNotes:\u003c\/h3\u003e\n\u003cp\u003e• The conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only\u003cbr\u003e• Please note \"cleanroom qualification\" in your order\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e• Size : \u003c\/b\u003e18 AWG\u003cb\u003e\u003cbr\u003e• No. cores x cross-sec. mm²: \u003c\/b\u003e2 x 1\u003cb\u003e\u003cbr\u003e• Outer Ø mm, approx:\u003c\/b\u003e 5.6\u003cb\u003e\u003cbr\u003e• Cu factor per km: \u003c\/b\u003e19.2 \u003cb\u003e\u003cbr\u003e• Weight kg\/km, approx:\u003c\/b\u003e 63.0\u003cbr\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":63153057300849,"sku":"NNC11241","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PML_fcf6a2d7-7e99-4bf2-82cb-18f66d0ddb32.png?v=1770358731"}],"url":"https:\/\/nassaunationalcable.com\/collections\/helukabel-jz-500-hmh-oz-500-hmh-highly-flame-retardant-control-and-connection-cable.oembed?page=8","provider":"NassauNationalCable","version":"1.0","type":"link"}