{"title":"Gaalflex Bare Copper Shielded Al Tape TC Braid PVC Tray VFD 1405 600V Cable","description":"","products":[{"product_id":"14-awg-4c-bare-copper-shielded-al-tape-tc-braid-pvc-gaalflex-tray-vfd-1405-600v-cable","title":"14 AWG 4C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/F2143-American-Industrial-Mining-Cables_removed_7.pdf?v=1703677301\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e14 AWG 4C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 14 AWG 4C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Gaalflex Bare Copper Shielded Al Tape TC Braid PVC Tray VFD 1405 600V Cable is a specialized cable designed for use in various industrial applications. It features a construction that includes bare copper conductors, shielding with aluminum tape and TC (Tinned Copper) braid, and a PVC jacket.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eGaalflex VFD 1405 600V Cable specifications\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eBare Copper Shielded Al Tape TC Braid PVC Tray Cable\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eInstrumentation cable standards\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eTray cable applications and usage\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eVFD cable for motor drives\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eShielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThis cable is shielded, which means it provides protection against electromagnetic interference (EMI) and radio-frequency interference (RFI). This shielding ensures stable and reliable signal transmission, critical for VFD systems.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eBare Copper Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe use of bare copper conductors ensures excellent electrical conductivity, reducing energy losses and allowing for efficient power transmission.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eAluminum Tape and TC Braid Shielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe combination of aluminum tape and tinned copper (TC) braid shielding provides enhanced protection against EMI and RFI, making it ideal for VFD applications where signal integrity is crucial.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003ePVC Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe PVC (Polyvinyl Chloride) jacket offers durability and resistance to environmental factors, making the cable suitable for both indoor and outdoor tray installations.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e600V Rating:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eWith a 600V rating, this cable can handle the voltage requirements of many VFD systems commonly used in industrial settings.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eNational Electrical Code (NEC):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor general electrical installation guidelines.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUL (Underwriters Laboratories):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eEnsuring safety and performance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIEEE Standards:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor specific applications like VFDs.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eLocal Electrical Codes:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eLocal regulations for compliance.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eConductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eflexible red copper conductor Cl. 5, acc. to IEC 60228, DIN VDE 0295 and UL standard 83\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eInsulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003efrom 18 AWG up to 16 AWG: GAALTHERM 520 from 14 AWG and over: GAALTHERM 591\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eCores color:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+3g..: 3 black conductors numbered + 3 green-yellow conductors divided in 3 inertstices 3x..+1g.. \/ 4g..+(2x..) or 4g..+(2x..+2x..): black cores with consecutive numbers acc. to EN 50334 + green\/yellow\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eStranding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+1g..: cores twisted together + fillers 3x..+3g..: phase units laid up with earth-conductors in interstices 4g..+(2x..) or 4g..+(2x..+2x..): control cores twisted in pair(s) and screened, supply cores and control screened pair(s) twisted together\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIndividual screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e4g..+(2x..) or 4g..+(2x..+2x..): aluminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOverall screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ealuminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOuter Sheath:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eblack (similar RAL 9005), GAALTHERM 520\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUV resistant\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eoutdoor use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003einstallation in hazardous areas\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 2277 WTTC or Flexible Motor Supply\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 1277 (Oil-resistant according to UL OIL RES I and Water-resistant, UL 90°C Dry or 90°C Wet )\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUL only for TC-ER use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request c(UL) type CIC\/TC FT4, AWM I\/II A\/B FT4\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request DIRECT BURIAL\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to to NFPA 79 2007 and NEC 336.10(7) Class 1, Div. 2 Art. 336, 392, 501\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for application acc. to EN 55011, DIN VDE 0875 and EN 61800-3\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for chain application, see technical data*\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eRoHS and CE approval\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• No. of cores x cross section n x AWG\/MCM:\u003c\/strong\u003e\u003cspan\u003e 4 G 14\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Outer Ø inches\/mm ±10%:\u003c\/strong\u003e\u003cspan\u003e 0,456 - 11,4\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Nominal voltage:\u003c\/strong\u003e\u003cspan\u003e UL 1277 TC-ER-600 V, UL 2277 WTTC \/ Flexible Motor Supply-1000 V, IEC: Uo\/U 600\/1000 V\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Temperature range UL:\u003cspan\u003e  \u003c\/span\u003e\u003c\/strong\u003eup to 90°C Fixed laying: - 40 oC up to + 105 oC Flexible installation: - 5 oC up to + 105 oC\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Min. bending radius:\u003c\/strong\u003e\u003cspan\u003e Fixed laying: 6 x d Flexible application: 20 x d\u003cbr\u003e\u003cstrong\u003e• Copper weight Lbs\/Mft: \u003c\/strong\u003e91,4\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Cable weight approx. Lbs\/Mft:\u003c\/strong\u003e\u003cspan\u003e 150,5\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e\u003cspan\u003e 33290F70041A14\u003c\/span\u003e\u003c\/p\u003e","brand":"Elettrotek Kabel","offers":[{"title":"Default Title","offer_id":44264315748506,"sku":"33290F70041A14","price":2.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/308_f3075a06-3be3-4e9a-98a6-11d4707aeda1.png?v=1762987831"},{"product_id":"12-awg-4c-bare-copper-shielded-al-tape-tc-braid-pvc-gaalflex-tray-vfd-1405-600v-cable","title":"12 AWG 4C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/F2143-American-Industrial-Mining-Cables_removed_7.pdf?v=1703677301\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e12 AWG 4C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 12 AWG 4C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Gaalflex Bare Copper Shielded Al Tape TC Braid PVC Tray VFD 1405 600V Cable is a specialized cable designed for use in various industrial applications. It features a construction that includes bare copper conductors, shielding with aluminum tape and TC (Tinned Copper) braid, and a PVC jacket.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eGaalflex VFD 1405 600V Cable specifications\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eBare Copper Shielded Al Tape TC Braid PVC Tray Cable\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eInstrumentation cable standards\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eTray cable applications and usage\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eVFD cable for motor drives\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eShielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThis cable is shielded, which means it provides protection against electromagnetic interference (EMI) and radio-frequency interference (RFI). This shielding ensures stable and reliable signal transmission, critical for VFD systems.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eBare Copper Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe use of bare copper conductors ensures excellent electrical conductivity, reducing energy losses and allowing for efficient power transmission.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eAluminum Tape and TC Braid Shielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe combination of aluminum tape and tinned copper (TC) braid shielding provides enhanced protection against EMI and RFI, making it ideal for VFD applications where signal integrity is crucial.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003ePVC Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe PVC (Polyvinyl Chloride) jacket offers durability and resistance to environmental factors, making the cable suitable for both indoor and outdoor tray installations.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e600V Rating:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eWith a 600V rating, this cable can handle the voltage requirements of many VFD systems commonly used in industrial settings.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eNational Electrical Code (NEC):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor general electrical installation guidelines.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUL (Underwriters Laboratories):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eEnsuring safety and performance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIEEE Standards:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor specific applications like VFDs.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eLocal Electrical Codes:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eLocal regulations for compliance.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eConductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eflexible red copper conductor Cl. 5, acc. to IEC 60228, DIN VDE 0295 and UL standard 83\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eInsulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003efrom 18 AWG up to 16 AWG: GAALTHERM 520 from 14 AWG and over: GAALTHERM 591\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eCores color:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+3g..: 3 black conductors numbered + 3 green-yellow conductors divided in 3 inertstices 3x..+1g.. \/ 4g..+(2x..) or 4g..+(2x..+2x..): black cores with consecutive numbers acc. to EN 50334 + green\/yellow\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eStranding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+1g..: cores twisted together + fillers 3x..+3g..: phase units laid up with earth-conductors in interstices 4g..+(2x..) or 4g..+(2x..+2x..): control cores twisted in pair(s) and screened, supply cores and control screened pair(s) twisted together\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIndividual screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e4g..+(2x..) or 4g..+(2x..+2x..): aluminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOverall screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ealuminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOuter Sheath:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eblack (similar RAL 9005), GAALTHERM 520\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUV resistant\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eoutdoor use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003einstallation in hazardous areas\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 2277 WTTC or Flexible Motor Supply\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 1277 (Oil-resistant according to UL OIL RES I and Water-resistant, UL 90°C Dry or 90°C Wet )\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUL only for TC-ER use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request c(UL) type CIC\/TC FT4, AWM I\/II A\/B FT4\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request DIRECT BURIAL\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to to NFPA 79 2007 and NEC 336.10(7) Class 1, Div. 2 Art. 336, 392, 501\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for application acc. to EN 55011, DIN VDE 0875 and EN 61800-3\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for chain application, see technical data*\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eRoHS and CE approval\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• No. of cores x cross section n x AWG\/MCM:\u003c\/strong\u003e\u003cspan\u003e 4 G 12\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Outer Ø inches\/mm ±10%:\u003c\/strong\u003e\u003cspan\u003e 0,52 - 13\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Nominal voltage:\u003c\/strong\u003e\u003cspan\u003e UL 1277 TC-ER-600 V, UL 2277 WTTC \/ Flexible Motor Supply-1000 V, IEC: Uo\/U 600\/1000 V\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Temperature range UL:\u003cspan\u003e  \u003c\/span\u003e\u003c\/strong\u003eup to 90°C Fixed laying: - 40 oC up to + 105 oC Flexible installation: - 5 oC up to + 105 oC\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Min. bending radius:\u003c\/strong\u003e\u003cspan\u003e Fixed laying: 6 x d Flexible application: 20 x d\u003cbr\u003e\u003cstrong\u003e• Copper weight Lbs\/Mft:\u003c\/strong\u003e 136,4\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Cable weight approx. Lbs\/Mft:\u003c\/strong\u003e\u003cspan\u003e 209,7\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e\u003cspan\u003e 33290F70041A12\u003c\/span\u003e\u003c\/p\u003e","brand":"Elettrotek Kabel","offers":[{"title":"Default Title","offer_id":44264317911194,"sku":"33290F70041A12","price":4.14,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/308_bbdb0b08-18ae-44f1-8f1f-0c4fcf7c32a1.png?v=1762987834"},{"product_id":"10-awg-4c-bare-copper-shielded-al-tape-tc-braid-pvc-gaalflex-tray-vfd-1405-600v-cable","title":"10 AWG 4C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/F2143-American-Industrial-Mining-Cables_removed_7.pdf?v=1703677301\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e10 AWG 4C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 10 AWG 4C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Gaalflex Bare Copper Shielded Al Tape TC Braid PVC Tray VFD 1405 600V Cable is a specialized cable designed for use in various industrial applications. It features a construction that includes bare copper conductors, shielding with aluminum tape and TC (Tinned Copper) braid, and a PVC jacket.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eGaalflex VFD 1405 600V Cable specifications\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eBare Copper Shielded Al Tape TC Braid PVC Tray Cable\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eInstrumentation cable standards\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eTray cable applications and usage\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eVFD cable for motor drives\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eShielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThis cable is shielded, which means it provides protection against electromagnetic interference (EMI) and radio-frequency interference (RFI). This shielding ensures stable and reliable signal transmission, critical for VFD systems.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eBare Copper Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe use of bare copper conductors ensures excellent electrical conductivity, reducing energy losses and allowing for efficient power transmission.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eAluminum Tape and TC Braid Shielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe combination of aluminum tape and tinned copper (TC) braid shielding provides enhanced protection against EMI and RFI, making it ideal for VFD applications where signal integrity is crucial.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003ePVC Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe PVC (Polyvinyl Chloride) jacket offers durability and resistance to environmental factors, making the cable suitable for both indoor and outdoor tray installations.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e600V Rating:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eWith a 600V rating, this cable can handle the voltage requirements of many VFD systems commonly used in industrial settings.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eNational Electrical Code (NEC):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor general electrical installation guidelines.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUL (Underwriters Laboratories):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eEnsuring safety and performance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIEEE Standards:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor specific applications like VFDs.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eLocal Electrical Codes:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eLocal regulations for compliance.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eConductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eflexible red copper conductor Cl. 5, acc. to IEC 60228, DIN VDE 0295 and UL standard 83\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eInsulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003efrom 18 AWG up to 16 AWG: GAALTHERM 520 from 14 AWG and over: GAALTHERM 591\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eCores color:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+3g..: 3 black conductors numbered + 3 green-yellow conductors divided in 3 inertstices 3x..+1g.. \/ 4g..+(2x..) or 4g..+(2x..+2x..): black cores with consecutive numbers acc. to EN 50334 + green\/yellow\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eStranding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+1g..: cores twisted together + fillers 3x..+3g..: phase units laid up with earth-conductors in interstices 4g..+(2x..) or 4g..+(2x..+2x..): control cores twisted in pair(s) and screened, supply cores and control screened pair(s) twisted together\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIndividual screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e4g..+(2x..) or 4g..+(2x..+2x..): aluminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOverall screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ealuminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOuter Sheath:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eblack (similar RAL 9005), GAALTHERM 520\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUV resistant\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eoutdoor use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003einstallation in hazardous areas\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 2277 WTTC or Flexible Motor Supply\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 1277 (Oil-resistant according to UL OIL RES I and Water-resistant, UL 90°C Dry or 90°C Wet )\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUL only for TC-ER use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request c(UL) type CIC\/TC FT4, AWM I\/II A\/B FT4\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request DIRECT BURIAL\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to to NFPA 79 2007 and NEC 336.10(7) Class 1, Div. 2 Art. 336, 392, 501\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for application acc. to EN 55011, DIN VDE 0875 and EN 61800-3\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for chain application, see technical data*\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eRoHS and CE approval\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• No. of cores x cross section n x AWG\/MCM:\u003c\/strong\u003e\u003cspan\u003e 4 G 10\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Outer Ø inches\/mm ±10%:\u003c\/strong\u003e\u003cspan\u003e 0,612 - 15,3\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Nominal voltage:\u003c\/strong\u003e\u003cspan\u003e UL 1277 TC-ER-600 V, UL 2277 WTTC \/ Flexible Motor Supply-1000 V, IEC: Uo\/U 600\/1000 V\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Temperature range UL:\u003cspan\u003e  \u003c\/span\u003e\u003c\/strong\u003eup to 90°C Fixed laying: - 40 oC up to + 105 oC Flexible installation: - 5 oC up to + 105 oC\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Min. bending radius:\u003c\/strong\u003e\u003cspan\u003e Fixed laying: 6 x d Flexible application: 20 x d\u003cbr\u003e\u003cstrong\u003e• Copper weight Lbs\/Mft:\u003c\/strong\u003e 202,3\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Cable weight approx. Lbs\/Mft:\u003c\/strong\u003e\u003cspan\u003e 301,1\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e\u003cspan\u003e 33290F70041A10\u003c\/span\u003e\u003c\/p\u003e","brand":"Elettrotek Kabel","offers":[{"title":"Default Title","offer_id":44264321187994,"sku":"33290F70041A10","price":5.58,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/308_a8707596-aa33-411b-9433-5c7eff357ff4.png?v=1762987837"},{"product_id":"8-awg-4c-bare-copper-shielded-al-tape-tc-braid-pvc-gaalflex-tray-vfd-1405-600v-cable","title":"8 AWG 4C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/F2143-American-Industrial-Mining-Cables_removed_7.pdf?v=1703677301\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e8 AWG 4C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 8 AWG 4C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Gaalflex Bare Copper Shielded Al Tape TC Braid PVC Tray VFD 1405 600V Cable is a specialized cable designed for use in various industrial applications. It features a construction that includes bare copper conductors, shielding with aluminum tape and TC (Tinned Copper) braid, and a PVC jacket.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eGaalflex VFD 1405 600V Cable specifications\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eBare Copper Shielded Al Tape TC Braid PVC Tray Cable\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eInstrumentation cable standards\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eTray cable applications and usage\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eVFD cable for motor drives\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eShielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThis cable is shielded, which means it provides protection against electromagnetic interference (EMI) and radio-frequency interference (RFI). This shielding ensures stable and reliable signal transmission, critical for VFD systems.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eBare Copper Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe use of bare copper conductors ensures excellent electrical conductivity, reducing energy losses and allowing for efficient power transmission.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eAluminum Tape and TC Braid Shielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe combination of aluminum tape and tinned copper (TC) braid shielding provides enhanced protection against EMI and RFI, making it ideal for VFD applications where signal integrity is crucial.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003ePVC Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe PVC (Polyvinyl Chloride) jacket offers durability and resistance to environmental factors, making the cable suitable for both indoor and outdoor tray installations.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e600V Rating:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eWith a 600V rating, this cable can handle the voltage requirements of many VFD systems commonly used in industrial settings.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eNational Electrical Code (NEC):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor general electrical installation guidelines.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUL (Underwriters Laboratories):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eEnsuring safety and performance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIEEE Standards:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor specific applications like VFDs.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eLocal Electrical Codes:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eLocal regulations for compliance.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eConductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eflexible red copper conductor Cl. 5, acc. to IEC 60228, DIN VDE 0295 and UL standard 83\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eInsulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003efrom 18 AWG up to 16 AWG: GAALTHERM 520 from 14 AWG and over: GAALTHERM 591\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eCores color:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+3g..: 3 black conductors numbered + 3 green-yellow conductors divided in 3 inertstices 3x..+1g.. \/ 4g..+(2x..) or 4g..+(2x..+2x..): black cores with consecutive numbers acc. to EN 50334 + green\/yellow\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eStranding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+1g..: cores twisted together + fillers 3x..+3g..: phase units laid up with earth-conductors in interstices 4g..+(2x..) or 4g..+(2x..+2x..): control cores twisted in pair(s) and screened, supply cores and control screened pair(s) twisted together\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIndividual screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e4g..+(2x..) or 4g..+(2x..+2x..): aluminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOverall screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ealuminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOuter Sheath:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eblack (similar RAL 9005), GAALTHERM 520\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUV resistant\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eoutdoor use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003einstallation in hazardous areas\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 2277 WTTC or Flexible Motor Supply\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 1277 (Oil-resistant according to UL OIL RES I and Water-resistant, UL 90°C Dry or 90°C Wet )\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUL only for TC-ER use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request c(UL) type CIC\/TC FT4, AWM I\/II A\/B FT4\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request DIRECT BURIAL\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to to NFPA 79 2007 and NEC 336.10(7) Class 1, Div. 2 Art. 336, 392, 501\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for application acc. to EN 55011, DIN VDE 0875 and EN 61800-3\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for chain application, see technical data*\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eRoHS and CE approval\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• No. of cores x cross section n x AWG\/MCM:\u003c\/strong\u003e\u003cspan\u003e 4 G 8\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Outer Ø inches\/mm ±10%:\u003c\/strong\u003e\u003cspan\u003e 0,776 - 19,4\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Nominal voltage:\u003c\/strong\u003e\u003cspan\u003e UL 1277 TC-ER-600 V, UL 2277 WTTC \/ Flexible Motor Supply-1000 V, IEC: Uo\/U 600\/1000 V\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Temperature range UL:\u003cspan\u003e  \u003c\/span\u003e\u003c\/strong\u003eup to 90°C Fixed laying: - 40 oC up to + 105 oC Flexible installation: - 5 oC up to + 105 oC\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Min. bending radius:\u003c\/strong\u003e\u003cspan\u003e Fixed laying: 6 x d Flexible application: 20 x d\u003cbr\u003e\u003cstrong\u003e• Copper weight Lbs\/Mft:\u003c\/strong\u003e 323,2\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Cable weight approx. Lbs\/Mft:\u003c\/strong\u003e\u003cspan\u003e 479,8\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e\u003cspan\u003e 33290F70041A08\u003c\/span\u003e\u003c\/p\u003e","brand":"Elettrotek Kabel","offers":[{"title":"Default Title","offer_id":44264322597018,"sku":"33290F70041A08","price":8.76,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/308_c42db967-d2e7-49e5-80bc-af8ddc9c2659.png?v=1759825836"},{"product_id":"6-awg-4c-bare-copper-shielded-al-tape-tc-braid-pvc-gaalflex-tray-vfd-1405-600v-cable","title":"6 AWG 4C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/F2143-American-Industrial-Mining-Cables_removed_7.pdf?v=1703677301\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e6 AWG 4C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 6 AWG 4C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Gaalflex Bare Copper Shielded Al Tape TC Braid PVC Tray VFD 1405 600V Cable is a specialized cable designed for use in various industrial applications. It features a construction that includes bare copper conductors, shielding with aluminum tape and TC (Tinned Copper) braid, and a PVC jacket.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eGaalflex VFD 1405 600V Cable specifications\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eBare Copper Shielded Al Tape TC Braid PVC Tray Cable\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eInstrumentation cable standards\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eTray cable applications and usage\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eVFD cable for motor drives\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eShielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThis cable is shielded, which means it provides protection against electromagnetic interference (EMI) and radio-frequency interference (RFI). This shielding ensures stable and reliable signal transmission, critical for VFD systems.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eBare Copper Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe use of bare copper conductors ensures excellent electrical conductivity, reducing energy losses and allowing for efficient power transmission.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eAluminum Tape and TC Braid Shielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe combination of aluminum tape and tinned copper (TC) braid shielding provides enhanced protection against EMI and RFI, making it ideal for VFD applications where signal integrity is crucial.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003ePVC Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe PVC (Polyvinyl Chloride) jacket offers durability and resistance to environmental factors, making the cable suitable for both indoor and outdoor tray installations.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e600V Rating:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eWith a 600V rating, this cable can handle the voltage requirements of many VFD systems commonly used in industrial settings.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eNational Electrical Code (NEC):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor general electrical installation guidelines.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUL (Underwriters Laboratories):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eEnsuring safety and performance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIEEE Standards:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor specific applications like VFDs.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eLocal Electrical Codes:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eLocal regulations for compliance.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eConductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eflexible red copper conductor Cl. 5, acc. to IEC 60228, DIN VDE 0295 and UL standard 83\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eInsulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003efrom 18 AWG up to 16 AWG: GAALTHERM 520 from 14 AWG and over: GAALTHERM 591\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eCores color:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+3g..: 3 black conductors numbered + 3 green-yellow conductors divided in 3 inertstices 3x..+1g.. \/ 4g..+(2x..) or 4g..+(2x..+2x..): black cores with consecutive numbers acc. to EN 50334 + green\/yellow\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eStranding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+1g..: cores twisted together + fillers 3x..+3g..: phase units laid up with earth-conductors in interstices 4g..+(2x..) or 4g..+(2x..+2x..): control cores twisted in pair(s) and screened, supply cores and control screened pair(s) twisted together\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIndividual screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e4g..+(2x..) or 4g..+(2x..+2x..): aluminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOverall screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ealuminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOuter Sheath:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eblack (similar RAL 9005), GAALTHERM 520\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUV resistant\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eoutdoor use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003einstallation in hazardous areas\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 2277 WTTC or Flexible Motor Supply\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 1277 (Oil-resistant according to UL OIL RES I and Water-resistant, UL 90°C Dry or 90°C Wet )\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUL only for TC-ER use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request c(UL) type CIC\/TC FT4, AWM I\/II A\/B FT4\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request DIRECT BURIAL\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to to NFPA 79 2007 and NEC 336.10(7) Class 1, Div. 2 Art. 336, 392, 501\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for application acc. to EN 55011, DIN VDE 0875 and EN 61800-3\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for chain application, see technical data*\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eRoHS and CE approval\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• No. of cores x cross section n x AWG\/MCM:\u003c\/strong\u003e\u003cspan\u003e 4 G 6\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Outer Ø inches\/mm ±10%:\u003c\/strong\u003e\u003cspan\u003e 0,912 - 22,8\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Nominal voltage:\u003c\/strong\u003e\u003cspan\u003e UL 1277 TC-ER-600 V, UL 2277 WTTC \/ Flexible Motor Supply-1000 V, IEC: Uo\/U 600\/1000 V\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Temperature range UL:\u003cspan\u003e  \u003c\/span\u003e\u003c\/strong\u003eup to 90°C Fixed laying: - 40 oC up to + 105 oC Flexible installation: - 5 oC up to + 105 oC\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Min. bending radius:\u003c\/strong\u003e\u003cspan\u003e Fixed laying: 6 x d Flexible application: 20 x d\u003cbr\u003e\u003cstrong\u003e• Copper weight Lbs\/Mft:\u003c\/strong\u003e 489,2\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Cable weight approx. Lbs\/Mft:\u003c\/strong\u003e\u003cspan\u003e 702,2\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e\u003cspan\u003e 33290F70041A06\u003c\/span\u003e\u003c\/p\u003e","brand":"Elettrotek Kabel","offers":[{"title":"Default Title","offer_id":44264325218458,"sku":"33290F70041A06","price":13.32,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/308_282ccc43-511c-4da4-b4b2-d7544d08fd58.png?v=1762987840"},{"product_id":"4-awg-4c-bare-copper-shielded-al-tape-tc-braid-pvc-gaalflex-tray-vfd-1405-600v-cable","title":"4 AWG 4C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/F2143-American-Industrial-Mining-Cables_removed_7.pdf?v=1703677301\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e4 AWG 4C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 4 AWG 4C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Gaalflex Bare Copper Shielded Al Tape TC Braid PVC Tray VFD 1405 600V Cable is a specialized cable designed for use in various industrial applications. It features a construction that includes bare copper conductors, shielding with aluminum tape and TC (Tinned Copper) braid, and a PVC jacket.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eGaalflex VFD 1405 600V Cable specifications\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eBare Copper Shielded Al Tape TC Braid PVC Tray Cable\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eInstrumentation cable standards\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eTray cable applications and usage\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eVFD cable for motor drives\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eShielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThis cable is shielded, which means it provides protection against electromagnetic interference (EMI) and radio-frequency interference (RFI). This shielding ensures stable and reliable signal transmission, critical for VFD systems.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eBare Copper Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe use of bare copper conductors ensures excellent electrical conductivity, reducing energy losses and allowing for efficient power transmission.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eAluminum Tape and TC Braid Shielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe combination of aluminum tape and tinned copper (TC) braid shielding provides enhanced protection against EMI and RFI, making it ideal for VFD applications where signal integrity is crucial.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003ePVC Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe PVC (Polyvinyl Chloride) jacket offers durability and resistance to environmental factors, making the cable suitable for both indoor and outdoor tray installations.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e600V Rating:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eWith a 600V rating, this cable can handle the voltage requirements of many VFD systems commonly used in industrial settings.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eNational Electrical Code (NEC):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor general electrical installation guidelines.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUL (Underwriters Laboratories):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eEnsuring safety and performance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIEEE Standards:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor specific applications like VFDs.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eLocal Electrical Codes:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eLocal regulations for compliance.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eConductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eflexible red copper conductor Cl. 5, acc. to IEC 60228, DIN VDE 0295 and UL standard 83\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eInsulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003efrom 18 AWG up to 16 AWG: GAALTHERM 520 from 14 AWG and over: GAALTHERM 591\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eCores color:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+3g..: 3 black conductors numbered + 3 green-yellow conductors divided in 3 inertstices 3x..+1g.. \/ 4g..+(2x..) or 4g..+(2x..+2x..): black cores with consecutive numbers acc. to EN 50334 + green\/yellow\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eStranding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+1g..: cores twisted together + fillers 3x..+3g..: phase units laid up with earth-conductors in interstices 4g..+(2x..) or 4g..+(2x..+2x..): control cores twisted in pair(s) and screened, supply cores and control screened pair(s) twisted together\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIndividual screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e4g..+(2x..) or 4g..+(2x..+2x..): aluminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOverall screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ealuminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOuter Sheath:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eblack (similar RAL 9005), GAALTHERM 520\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUV resistant\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eoutdoor use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003einstallation in hazardous areas\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 2277 WTTC or Flexible Motor Supply\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 1277 (Oil-resistant according to UL OIL RES I and Water-resistant, UL 90°C Dry or 90°C Wet )\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUL only for TC-ER use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request c(UL) type CIC\/TC FT4, AWM I\/II A\/B FT4\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request DIRECT BURIAL\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to to NFPA 79 2007 and NEC 336.10(7) Class 1, Div. 2 Art. 336, 392, 501\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for application acc. to EN 55011, DIN VDE 0875 and EN 61800-3\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for chain application, see technical data*\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eRoHS and CE approval\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• No. of cores x cross section n x AWG\/MCM:\u003c\/strong\u003e\u003cspan\u003e 4 G 4\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Outer Ø inches\/mm ±10%:\u003c\/strong\u003e\u003cspan\u003e 1,052 - 26,3\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Nominal voltage:\u003c\/strong\u003e\u003cspan\u003e UL 1277 TC-ER-600 V, UL 2277 WTTC \/ Flexible Motor Supply-1000 V, IEC: Uo\/U 600\/1000 V\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Temperature range UL:\u003cspan\u003e  \u003c\/span\u003e\u003c\/strong\u003eup to 90°C Fixed laying: - 40 oC up to + 105 oC Flexible installation: - 5 oC up to + 105 oC\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Min. bending radius:\u003c\/strong\u003e\u003cspan\u003e Fixed laying: 6 x d Flexible application: 20 x d\u003cbr\u003e\u003cstrong\u003e• Copper weight Lbs\/Mft:\u003c\/strong\u003e 733,8\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Cable weight approx. Lbs\/Mft:\u003c\/strong\u003e\u003cspan\u003e 1004\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e\u003cspan\u003e 33290F70041A04\u003c\/span\u003e\u003c\/p\u003e","brand":"Elettrotek Kabel","offers":[{"title":"Default Title","offer_id":44264331772058,"sku":"33290F70041A04","price":19.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/308_09618e79-8434-4888-bf4b-02a8f11f112f.png?v=1762987842"},{"product_id":"2-awg-4c-bare-copper-shielded-al-tape-tc-braid-pvc-gaalflex-tray-vfd-1405-600v-cable","title":"2 AWG 4C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/F2143-American-Industrial-Mining-Cables_removed_7.pdf?v=1703677301\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e2 AWG 4C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 2 AWG 4C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Gaalflex Bare Copper Shielded Al Tape TC Braid PVC Tray VFD 1405 600V Cable is a specialized cable designed for use in various industrial applications. It features a construction that includes bare copper conductors, shielding with aluminum tape and TC (Tinned Copper) braid, and a PVC jacket.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eGaalflex VFD 1405 600V Cable specifications\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eBare Copper Shielded Al Tape TC Braid PVC Tray Cable\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eInstrumentation cable standards\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eTray cable applications and usage\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eVFD cable for motor drives\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eShielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThis cable is shielded, which means it provides protection against electromagnetic interference (EMI) and radio-frequency interference (RFI). This shielding ensures stable and reliable signal transmission, critical for VFD systems.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eBare Copper Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe use of bare copper conductors ensures excellent electrical conductivity, reducing energy losses and allowing for efficient power transmission.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eAluminum Tape and TC Braid Shielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe combination of aluminum tape and tinned copper (TC) braid shielding provides enhanced protection against EMI and RFI, making it ideal for VFD applications where signal integrity is crucial.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003ePVC Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe PVC (Polyvinyl Chloride) jacket offers durability and resistance to environmental factors, making the cable suitable for both indoor and outdoor tray installations.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e600V Rating:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eWith a 600V rating, this cable can handle the voltage requirements of many VFD systems commonly used in industrial settings.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eNational Electrical Code (NEC):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor general electrical installation guidelines.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUL (Underwriters Laboratories):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eEnsuring safety and performance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIEEE Standards:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor specific applications like VFDs.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eLocal Electrical Codes:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eLocal regulations for compliance.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eConductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eflexible red copper conductor Cl. 5, acc. to IEC 60228, DIN VDE 0295 and UL standard 83\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eInsulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003efrom 18 AWG up to 16 AWG: GAALTHERM 520 from 14 AWG and over: GAALTHERM 591\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eCores color:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+3g..: 3 black conductors numbered + 3 green-yellow conductors divided in 3 inertstices 3x..+1g.. \/ 4g..+(2x..) or 4g..+(2x..+2x..): black cores with consecutive numbers acc. to EN 50334 + green\/yellow\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eStranding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+1g..: cores twisted together + fillers 3x..+3g..: phase units laid up with earth-conductors in interstices 4g..+(2x..) or 4g..+(2x..+2x..): control cores twisted in pair(s) and screened, supply cores and control screened pair(s) twisted together\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIndividual screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e4g..+(2x..) or 4g..+(2x..+2x..): aluminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOverall screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ealuminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOuter Sheath:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eblack (similar RAL 9005), GAALTHERM 520\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUV resistant\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eoutdoor use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003einstallation in hazardous areas\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 2277 WTTC or Flexible Motor Supply\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 1277 (Oil-resistant according to UL OIL RES I and Water-resistant, UL 90°C Dry or 90°C Wet )\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUL only for TC-ER use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request c(UL) type CIC\/TC FT4, AWM I\/II A\/B FT4\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request DIRECT BURIAL\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to to NFPA 79 2007 and NEC 336.10(7) Class 1, Div. 2 Art. 336, 392, 501\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for application acc. to EN 55011, DIN VDE 0875 and EN 61800-3\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for chain application, see technical data*\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eRoHS and CE approval\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• No. of cores x cross section n x AWG\/MCM:\u003c\/strong\u003e\u003cspan\u003e 4 G 2\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Outer Ø inches\/mm ±10%:\u003c\/strong\u003e\u003cspan\u003e 1,168 - 29,2\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Nominal voltage:\u003c\/strong\u003e\u003cspan\u003e UL 1277 TC-ER-600 V, UL 2277 WTTC \/ Flexible Motor Supply-1000 V, IEC: Uo\/U 600\/1000 V\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Temperature range UL:\u003cspan\u003e  \u003c\/span\u003e\u003c\/strong\u003eup to 90°C Fixed laying: - 40 oC up to + 105 oC Flexible installation: - 5 oC up to + 105 oC\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Min. bending radius:\u003c\/strong\u003e\u003cspan\u003e Fixed laying: 6 x d Flexible application: 20 x d\u003cbr\u003e\u003cstrong\u003e• Copper weight Lbs\/Mft:\u003c\/strong\u003e 1009,3\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Cable weight approx. Lbs\/Mft:\u003c\/strong\u003e\u003cspan\u003e 1323,9\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e\u003cspan\u003e 33290F70041A02\u003c\/span\u003e\u003c\/p\u003e","brand":"Elettrotek Kabel","offers":[{"title":"Default Title","offer_id":44264367227034,"sku":"33290F70041A02","price":26.39,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/308_2c3bedc1-c850-4dd1-b624-ff24063cb422.png?v=1759825836"},{"product_id":"1-awg-4c-bare-copper-shielded-al-tape-tc-braid-pvc-gaalflex-tray-vfd-1405-600v-cable","title":"1 AWG 4C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/F2143-American-Industrial-Mining-Cables_removed_7.pdf?v=1703677301\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e1 AWG 4C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 1 AWG 4C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Gaalflex Bare Copper Shielded Al Tape TC Braid PVC Tray VFD 1405 600V Cable is a specialized cable designed for use in various industrial applications. It features a construction that includes bare copper conductors, shielding with aluminum tape and TC (Tinned Copper) braid, and a PVC jacket.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eGaalflex VFD 1405 600V Cable specifications\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eBare Copper Shielded Al Tape TC Braid PVC Tray Cable\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eInstrumentation cable standards\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eTray cable applications and usage\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eVFD cable for motor drives\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eShielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThis cable is shielded, which means it provides protection against electromagnetic interference (EMI) and radio-frequency interference (RFI). This shielding ensures stable and reliable signal transmission, critical for VFD systems.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eBare Copper Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe use of bare copper conductors ensures excellent electrical conductivity, reducing energy losses and allowing for efficient power transmission.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eAluminum Tape and TC Braid Shielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe combination of aluminum tape and tinned copper (TC) braid shielding provides enhanced protection against EMI and RFI, making it ideal for VFD applications where signal integrity is crucial.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003ePVC Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe PVC (Polyvinyl Chloride) jacket offers durability and resistance to environmental factors, making the cable suitable for both indoor and outdoor tray installations.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e600V Rating:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eWith a 600V rating, this cable can handle the voltage requirements of many VFD systems commonly used in industrial settings.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eNational Electrical Code (NEC):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor general electrical installation guidelines.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUL (Underwriters Laboratories):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eEnsuring safety and performance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIEEE Standards:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor specific applications like VFDs.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eLocal Electrical Codes:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eLocal regulations for compliance.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eConductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eflexible red copper conductor Cl. 5, acc. to IEC 60228, DIN VDE 0295 and UL standard 83\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eInsulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003efrom 18 AWG up to 16 AWG: GAALTHERM 520 from 14 AWG and over: GAALTHERM 591\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eCores color:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+3g..: 3 black conductors numbered + 3 green-yellow conductors divided in 3 inertstices 3x..+1g.. \/ 4g..+(2x..) or 4g..+(2x..+2x..): black cores with consecutive numbers acc. to EN 50334 + green\/yellow\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eStranding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+1g..: cores twisted together + fillers 3x..+3g..: phase units laid up with earth-conductors in interstices 4g..+(2x..) or 4g..+(2x..+2x..): control cores twisted in pair(s) and screened, supply cores and control screened pair(s) twisted together\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIndividual screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e4g..+(2x..) or 4g..+(2x..+2x..): aluminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOverall screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ealuminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOuter Sheath:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eblack (similar RAL 9005), GAALTHERM 520\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUV resistant\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eoutdoor use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003einstallation in hazardous areas\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 2277 WTTC or Flexible Motor Supply\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 1277 (Oil-resistant according to UL OIL RES I and Water-resistant, UL 90°C Dry or 90°C Wet )\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUL only for TC-ER use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request c(UL) type CIC\/TC FT4, AWM I\/II A\/B FT4\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request DIRECT BURIAL\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to to NFPA 79 2007 and NEC 336.10(7) Class 1, Div. 2 Art. 336, 392, 501\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for application acc. to EN 55011, DIN VDE 0875 and EN 61800-3\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for chain application, see technical data*\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eRoHS and CE approval\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• No. of cores x cross section n x AWG\/MCM:\u003c\/strong\u003e\u003cspan\u003e 4 G 1\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Outer Ø inches\/mm ±10%:\u003c\/strong\u003e\u003cspan\u003e 1,384 - 34,6\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Nominal voltage:\u003c\/strong\u003e\u003cspan\u003e UL 1277 TC-ER-600 V, UL 2277 WTTC \/ Flexible Motor Supply-1000 V, IEC: Uo\/U 600\/1000 V\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Temperature range UL:\u003cspan\u003e  \u003c\/span\u003e\u003c\/strong\u003eup to 90°C Fixed laying: - 40 oC up to + 105 oC Flexible installation: - 5 oC up to + 105 oC\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Min. bending radius:\u003c\/strong\u003e\u003cspan\u003e Fixed laying: 6 x d Flexible application: 20 x d\u003cbr\u003e\u003cstrong\u003e• Copper weight Lbs\/Mft:\u003c\/strong\u003e 1446,8\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Cable weight approx. Lbs\/Mft:\u003c\/strong\u003e\u003cspan\u003e 1872,9\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e\u003cspan\u003e 33290F70041A01\u003c\/span\u003e\u003c\/p\u003e","brand":"Elettrotek Kabel","offers":[{"title":"Default Title","offer_id":44264375058586,"sku":"33290F70041A01","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/308_8e7d0e17-011d-455c-bc90-e8ee1064f8e8.png?v=1762987846"},{"product_id":"2-0-awg-4c-bare-copper-shielded-al-tape-tc-braid-pvc-gaalflex-tray-vfd-1405-600v-cable","title":"2\/0 AWG 4C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/F2143-American-Industrial-Mining-Cables_removed_7.pdf?v=1703677301\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e2\/0 AWG 4C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 2\/0 AWG 4C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Gaalflex Bare Copper Shielded Al Tape TC Braid PVC Tray VFD 1405 600V Cable is a specialized cable designed for use in various industrial applications. It features a construction that includes bare copper conductors, shielding with aluminum tape and TC (Tinned Copper) braid, and a PVC jacket.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eGaalflex VFD 1405 600V Cable specifications\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eBare Copper Shielded Al Tape TC Braid PVC Tray Cable\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eInstrumentation cable standards\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eTray cable applications and usage\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eVFD cable for motor drives\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eShielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThis cable is shielded, which means it provides protection against electromagnetic interference (EMI) and radio-frequency interference (RFI). This shielding ensures stable and reliable signal transmission, critical for VFD systems.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eBare Copper Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe use of bare copper conductors ensures excellent electrical conductivity, reducing energy losses and allowing for efficient power transmission.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eAluminum Tape and TC Braid Shielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe combination of aluminum tape and tinned copper (TC) braid shielding provides enhanced protection against EMI and RFI, making it ideal for VFD applications where signal integrity is crucial.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003ePVC Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe PVC (Polyvinyl Chloride) jacket offers durability and resistance to environmental factors, making the cable suitable for both indoor and outdoor tray installations.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e600V Rating:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eWith a 600V rating, this cable can handle the voltage requirements of many VFD systems commonly used in industrial settings.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eNational Electrical Code (NEC):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor general electrical installation guidelines.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUL (Underwriters Laboratories):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eEnsuring safety and performance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIEEE Standards:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor specific applications like VFDs.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eLocal Electrical Codes:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eLocal regulations for compliance.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eConductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eflexible red copper conductor Cl. 5, acc. to IEC 60228, DIN VDE 0295 and UL standard 83\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eInsulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003efrom 18 AWG up to 16 AWG: GAALTHERM 520 from 14 AWG and over: GAALTHERM 591\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eCores color:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+3g..: 3 black conductors numbered + 3 green-yellow conductors divided in 3 inertstices 3x..+1g.. \/ 4g..+(2x..) or 4g..+(2x..+2x..): black cores with consecutive numbers acc. to EN 50334 + green\/yellow\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eStranding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+1g..: cores twisted together + fillers 3x..+3g..: phase units laid up with earth-conductors in interstices 4g..+(2x..) or 4g..+(2x..+2x..): control cores twisted in pair(s) and screened, supply cores and control screened pair(s) twisted together\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIndividual screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e4g..+(2x..) or 4g..+(2x..+2x..): aluminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOverall screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ealuminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOuter Sheath:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eblack (similar RAL 9005), GAALTHERM 520\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUV resistant\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eoutdoor use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003einstallation in hazardous areas\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 2277 WTTC or Flexible Motor Supply\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 1277 (Oil-resistant according to UL OIL RES I and Water-resistant, UL 90°C Dry or 90°C Wet )\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUL only for TC-ER use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request c(UL) type CIC\/TC FT4, AWM I\/II A\/B FT4\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request DIRECT BURIAL\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to to NFPA 79 2007 and NEC 336.10(7) Class 1, Div. 2 Art. 336, 392, 501\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for application acc. to EN 55011, DIN VDE 0875 and EN 61800-3\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for chain application, see technical data*\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eRoHS and CE approval\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• No. of cores x cross section n x AWG\/MCM:\u003c\/strong\u003e\u003cspan\u003e 4 G 2\/0\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Outer Ø inches\/mm ±10%:\u003c\/strong\u003e\u003cspan\u003e 1,584 - 39,6\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Nominal voltage:\u003c\/strong\u003e\u003cspan\u003e UL 1277 TC-ER-600 V, UL 2277 WTTC \/ Flexible Motor Supply-1000 V, IEC: Uo\/U 600\/1000 V\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Temperature range UL:\u003cspan\u003e  \u003c\/span\u003e\u003c\/strong\u003eup to 90°C Fixed laying: - 40 oC up to + 105 oC Flexible installation: - 5 oC up to + 105 oC\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Min. bending radius:\u003c\/strong\u003e\u003cspan\u003e Fixed laying: 6 x d Flexible application: 20 x d\u003cbr\u003e\u003cstrong\u003e• Copper weight Lbs\/Mft:\u003c\/strong\u003e 1990,5\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Cable weight approx. Lbs\/Mft:\u003c\/strong\u003e\u003cspan\u003e 2526,7\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e\u003cspan\u003e 33290F70041A2C\u003c\/span\u003e\u003c\/p\u003e","brand":"Elettrotek Kabel","offers":[{"title":"Default Title","offer_id":44264383742106,"sku":"33290F70041A2C","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/308_ca5b50ec-79cc-4d37-bef0-cf15bd34d5fe.png?v=1759825837"},{"product_id":"3-0-awg-4c-bare-copper-shielded-al-tape-tc-braid-pvc-gaalflex-tray-vfd-1405-600v-cable","title":"3\/0 AWG 4C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/F2143-American-Industrial-Mining-Cables_removed_7.pdf?v=1703677301\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e3\/0 AWG 4C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 3\/0 AWG 4C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Gaalflex Bare Copper Shielded Al Tape TC Braid PVC Tray VFD 1405 600V Cable is a specialized cable designed for use in various industrial applications. It features a construction that includes bare copper conductors, shielding with aluminum tape and TC (Tinned Copper) braid, and a PVC jacket.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eGaalflex VFD 1405 600V Cable specifications\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eBare Copper Shielded Al Tape TC Braid PVC Tray Cable\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eInstrumentation cable standards\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eTray cable applications and usage\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eVFD cable for motor drives\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eShielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThis cable is shielded, which means it provides protection against electromagnetic interference (EMI) and radio-frequency interference (RFI). This shielding ensures stable and reliable signal transmission, critical for VFD systems.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eBare Copper Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe use of bare copper conductors ensures excellent electrical conductivity, reducing energy losses and allowing for efficient power transmission.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eAluminum Tape and TC Braid Shielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe combination of aluminum tape and tinned copper (TC) braid shielding provides enhanced protection against EMI and RFI, making it ideal for VFD applications where signal integrity is crucial.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003ePVC Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe PVC (Polyvinyl Chloride) jacket offers durability and resistance to environmental factors, making the cable suitable for both indoor and outdoor tray installations.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e600V Rating:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eWith a 600V rating, this cable can handle the voltage requirements of many VFD systems commonly used in industrial settings.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eNational Electrical Code (NEC):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor general electrical installation guidelines.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUL (Underwriters Laboratories):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eEnsuring safety and performance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIEEE Standards:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor specific applications like VFDs.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eLocal Electrical Codes:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eLocal regulations for compliance.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eConductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eflexible red copper conductor Cl. 5, acc. to IEC 60228, DIN VDE 0295 and UL standard 83\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eInsulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003efrom 18 AWG up to 16 AWG: GAALTHERM 520 from 14 AWG and over: GAALTHERM 591\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eCores color:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+3g..: 3 black conductors numbered + 3 green-yellow conductors divided in 3 inertstices 3x..+1g.. \/ 4g..+(2x..) or 4g..+(2x..+2x..): black cores with consecutive numbers acc. to EN 50334 + green\/yellow\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eStranding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+1g..: cores twisted together + fillers 3x..+3g..: phase units laid up with earth-conductors in interstices 4g..+(2x..) or 4g..+(2x..+2x..): control cores twisted in pair(s) and screened, supply cores and control screened pair(s) twisted together\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIndividual screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e4g..+(2x..) or 4g..+(2x..+2x..): aluminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOverall screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ealuminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOuter Sheath:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eblack (similar RAL 9005), GAALTHERM 520\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUV resistant\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eoutdoor use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003einstallation in hazardous areas\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 2277 WTTC or Flexible Motor Supply\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 1277 (Oil-resistant according to UL OIL RES I and Water-resistant, UL 90°C Dry or 90°C Wet )\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUL only for TC-ER use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request c(UL) type CIC\/TC FT4, AWM I\/II A\/B FT4\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request DIRECT BURIAL\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to to NFPA 79 2007 and NEC 336.10(7) Class 1, Div. 2 Art. 336, 392, 501\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for application acc. to EN 55011, DIN VDE 0875 and EN 61800-3\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for chain application, see technical data*\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eRoHS and CE approval\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• No. of cores x cross section n x AWG\/MCM:\u003c\/strong\u003e\u003cspan\u003e 4 G 3\/0\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Outer Ø inches\/mm ±10%:\u003c\/strong\u003e\u003cspan\u003e 1,784 - 44,6\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Nominal voltage:\u003c\/strong\u003e\u003cspan\u003e UL 1277 TC-ER-600 V, UL 2277 WTTC \/ Flexible Motor Supply-1000 V, IEC: Uo\/U 600\/1000 V\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Temperature range UL:\u003cspan\u003e  \u003c\/span\u003e\u003c\/strong\u003eup to 90°C Fixed laying: - 40 oC up to + 105 oC Flexible installation: - 5 oC up to + 105 oC\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Min. bending radius:\u003c\/strong\u003e\u003cspan\u003e Fixed laying: 6 x d Flexible application: 20 x d\u003cbr\u003e\u003cstrong\u003e• Copper weight Lbs\/Mft:\u003c\/strong\u003e 2651\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Cable weight approx. Lbs\/Mft:\u003c\/strong\u003e\u003cspan\u003e 3332,4\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e\u003cspan\u003e 33290F70041A3C\u003c\/span\u003e\u003c\/p\u003e","brand":"Elettrotek Kabel","offers":[{"title":"Default Title","offer_id":44264386920602,"sku":"33290F70041A3C","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/308_40dd2aac-72e0-48a6-9801-04392f3e3641.png?v=1759825837"},{"product_id":"4-0-awg-4c-bare-copper-shielded-al-tape-tc-braid-pvc-gaalflex-tray-vfd-1405-600v-cable","title":"4\/0 AWG 4C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/F2143-American-Industrial-Mining-Cables_removed_7.pdf?v=1703677301\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e4\/0 AWG 4C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 4\/0 AWG 4C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Gaalflex Bare Copper Shielded Al Tape TC Braid PVC Tray VFD 1405 600V Cable is a specialized cable designed for use in various industrial applications. It features a construction that includes bare copper conductors, shielding with aluminum tape and TC (Tinned Copper) braid, and a PVC jacket.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eGaalflex VFD 1405 600V Cable specifications\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eBare Copper Shielded Al Tape TC Braid PVC Tray Cable\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eInstrumentation cable standards\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eTray cable applications and usage\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eVFD cable for motor drives\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eShielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThis cable is shielded, which means it provides protection against electromagnetic interference (EMI) and radio-frequency interference (RFI). This shielding ensures stable and reliable signal transmission, critical for VFD systems.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eBare Copper Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe use of bare copper conductors ensures excellent electrical conductivity, reducing energy losses and allowing for efficient power transmission.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eAluminum Tape and TC Braid Shielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe combination of aluminum tape and tinned copper (TC) braid shielding provides enhanced protection against EMI and RFI, making it ideal for VFD applications where signal integrity is crucial.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003ePVC Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe PVC (Polyvinyl Chloride) jacket offers durability and resistance to environmental factors, making the cable suitable for both indoor and outdoor tray installations.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e600V Rating:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eWith a 600V rating, this cable can handle the voltage requirements of many VFD systems commonly used in industrial settings.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eNational Electrical Code (NEC):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor general electrical installation guidelines.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUL (Underwriters Laboratories):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eEnsuring safety and performance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIEEE Standards:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor specific applications like VFDs.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eLocal Electrical Codes:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eLocal regulations for compliance.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eConductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eflexible red copper conductor Cl. 5, acc. to IEC 60228, DIN VDE 0295 and UL standard 83\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eInsulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003efrom 18 AWG up to 16 AWG: GAALTHERM 520 from 14 AWG and over: GAALTHERM 591\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eCores color:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+3g..: 3 black conductors numbered + 3 green-yellow conductors divided in 3 inertstices 3x..+1g.. \/ 4g..+(2x..) or 4g..+(2x..+2x..): black cores with consecutive numbers acc. to EN 50334 + green\/yellow\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eStranding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+1g..: cores twisted together + fillers 3x..+3g..: phase units laid up with earth-conductors in interstices 4g..+(2x..) or 4g..+(2x..+2x..): control cores twisted in pair(s) and screened, supply cores and control screened pair(s) twisted together\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIndividual screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e4g..+(2x..) or 4g..+(2x..+2x..): aluminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOverall screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ealuminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOuter Sheath:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eblack (similar RAL 9005), GAALTHERM 520\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUV resistant\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eoutdoor use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003einstallation in hazardous areas\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 2277 WTTC or Flexible Motor Supply\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 1277 (Oil-resistant according to UL OIL RES I and Water-resistant, UL 90°C Dry or 90°C Wet )\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUL only for TC-ER use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request c(UL) type CIC\/TC FT4, AWM I\/II A\/B FT4\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request DIRECT BURIAL\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to to NFPA 79 2007 and NEC 336.10(7) Class 1, Div. 2 Art. 336, 392, 501\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for application acc. to EN 55011, DIN VDE 0875 and EN 61800-3\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for chain application, see technical data*\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eRoHS and CE approval\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• No. of cores x cross section n x AWG\/MCM:\u003c\/strong\u003e\u003cspan\u003e 4 G 4\/0\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Outer Ø inches\/mm ±10%:\u003c\/strong\u003e\u003cspan\u003e 1,936 - 48,4\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Nominal voltage:\u003c\/strong\u003e\u003cspan\u003e UL 1277 TC-ER-600 V, UL 2277 WTTC \/ Flexible Motor Supply-1000 V, IEC: Uo\/U 600\/1000 V\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Temperature range UL:\u003cspan\u003e  \u003c\/span\u003e\u003c\/strong\u003eup to 90°C Fixed laying: - 40 oC up to + 105 oC Flexible installation: - 5 oC up to + 105 oC\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Min. bending radius:\u003c\/strong\u003e\u003cspan\u003e Fixed laying: 6 x d Flexible application: 20 x d\u003cbr\u003e\u003cstrong\u003e• Copper weight Lbs\/Mft:\u003c\/strong\u003e 3317,7\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Cable weight approx. Lbs\/Mft:\u003c\/strong\u003e\u003cspan\u003e 4085,1\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e\u003cspan\u003e 33290F70041A4C\u003c\/span\u003e\u003c\/p\u003e","brand":"Elettrotek Kabel","offers":[{"title":"Default Title","offer_id":44264392229018,"sku":"33290F70041A4C","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/308_7b48e88d-f499-4e6e-a776-dddd5bae55e9.png?v=1762987849"},{"product_id":"250-mcm-4c-bare-copper-shielded-al-tape-tc-braid-pvc-gaalflex-tray-vfd-1405-600v-cable","title":"250 MCM 4C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/F2143-American-Industrial-Mining-Cables_removed_7.pdf?v=1703677301\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e250 MCM 4C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 250 MCM 4C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Gaalflex Bare Copper Shielded Al Tape TC Braid PVC Tray VFD 1405 600V Cable is a specialized cable designed for use in various industrial applications. It features a construction that includes bare copper conductors, shielding with aluminum tape and TC (Tinned Copper) braid, and a PVC jacket.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eGaalflex VFD 1405 600V Cable specifications\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eBare Copper Shielded Al Tape TC Braid PVC Tray Cable\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eInstrumentation cable standards\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eTray cable applications and usage\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eVFD cable for motor drives\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eShielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThis cable is shielded, which means it provides protection against electromagnetic interference (EMI) and radio-frequency interference (RFI). This shielding ensures stable and reliable signal transmission, critical for VFD systems.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eBare Copper Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe use of bare copper conductors ensures excellent electrical conductivity, reducing energy losses and allowing for efficient power transmission.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eAluminum Tape and TC Braid Shielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe combination of aluminum tape and tinned copper (TC) braid shielding provides enhanced protection against EMI and RFI, making it ideal for VFD applications where signal integrity is crucial.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003ePVC Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe PVC (Polyvinyl Chloride) jacket offers durability and resistance to environmental factors, making the cable suitable for both indoor and outdoor tray installations.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e600V Rating:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eWith a 600V rating, this cable can handle the voltage requirements of many VFD systems commonly used in industrial settings.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eNational Electrical Code (NEC):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor general electrical installation guidelines.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUL (Underwriters Laboratories):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eEnsuring safety and performance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIEEE Standards:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor specific applications like VFDs.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eLocal Electrical Codes:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eLocal regulations for compliance.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eConductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eflexible red copper conductor Cl. 5, acc. to IEC 60228, DIN VDE 0295 and UL standard 83\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eInsulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003efrom 18 AWG up to 16 AWG: GAALTHERM 520 from 14 AWG and over: GAALTHERM 591\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eCores color:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+3g..: 3 black conductors numbered + 3 green-yellow conductors divided in 3 inertstices 3x..+1g.. \/ 4g..+(2x..) or 4g..+(2x..+2x..): black cores with consecutive numbers acc. to EN 50334 + green\/yellow\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eStranding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+1g..: cores twisted together + fillers 3x..+3g..: phase units laid up with earth-conductors in interstices 4g..+(2x..) or 4g..+(2x..+2x..): control cores twisted in pair(s) and screened, supply cores and control screened pair(s) twisted together\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIndividual screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e4g..+(2x..) or 4g..+(2x..+2x..): aluminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOverall screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ealuminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOuter Sheath:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eblack (similar RAL 9005), GAALTHERM 520\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUV resistant\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eoutdoor use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003einstallation in hazardous areas\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 2277 WTTC or Flexible Motor Supply\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 1277 (Oil-resistant according to UL OIL RES I and Water-resistant, UL 90°C Dry or 90°C Wet )\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUL only for TC-ER use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request c(UL) type CIC\/TC FT4, AWM I\/II A\/B FT4\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request DIRECT BURIAL\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to to NFPA 79 2007 and NEC 336.10(7) Class 1, Div. 2 Art. 336, 392, 501\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for application acc. to EN 55011, DIN VDE 0875 and EN 61800-3\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for chain application, see technical data*\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eRoHS and CE approval\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• No. of cores x cross section n x AWG\/MCM:\u003c\/strong\u003e\u003cspan\u003e 4 G 250\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Outer Ø inches\/mm ±10%:\u003c\/strong\u003e\u003cspan\u003e 2,088 - 52,2\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Nominal voltage:\u003c\/strong\u003e\u003cspan\u003e UL 1277 TC-ER-600 V, UL 2277 WTTC \/ Flexible Motor Supply-1000 V, IEC: Uo\/U 600\/1000 V\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Temperature range UL:\u003cspan\u003e  \u003c\/span\u003e\u003c\/strong\u003eup to 90°C Fixed laying: - 40 oC up to + 105 oC Flexible installation: - 5 oC up to + 105 oC\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Min. bending radius:\u003c\/strong\u003e\u003cspan\u003e Fixed laying: 6 x d Flexible application: 20 x d\u003cbr\u003e\u003cstrong\u003e• Copper weight Lbs\/Mft:\u003c\/strong\u003e 4110,6\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Cable weight approx. Lbs\/Mft:\u003c\/strong\u003e\u003cspan\u003e 4961,4\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e\u003cspan\u003e 33290F70041A5C \u003c\/span\u003e\u003c\/p\u003e","brand":"Elettrotek Kabel","offers":[{"title":"Default Title","offer_id":44264401535130,"sku":"33290F70041A5C","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/308_ef4b54a9-6501-4edf-bb8c-96594bae1d21.png?v=1759825839"},{"product_id":"350-mcm-4c-bare-copper-shielded-al-tape-tc-braid-pvc-gaalflex-tray-vfd-1405-600v-cable","title":"350 MCM 4C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/F2143-American-Industrial-Mining-Cables_removed_7.pdf?v=1703677301\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e350 MCM 4C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 350 MCM 4C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Gaalflex Bare Copper Shielded Al Tape TC Braid PVC Tray VFD 1405 600V Cable is a specialized cable designed for use in various industrial applications. It features a construction that includes bare copper conductors, shielding with aluminum tape and TC (Tinned Copper) braid, and a PVC jacket.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eGaalflex VFD 1405 600V Cable specifications\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eBare Copper Shielded Al Tape TC Braid PVC Tray Cable\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eInstrumentation cable standards\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eTray cable applications and usage\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eVFD cable for motor drives\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eShielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThis cable is shielded, which means it provides protection against electromagnetic interference (EMI) and radio-frequency interference (RFI). This shielding ensures stable and reliable signal transmission, critical for VFD systems.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eBare Copper Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe use of bare copper conductors ensures excellent electrical conductivity, reducing energy losses and allowing for efficient power transmission.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eAluminum Tape and TC Braid Shielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe combination of aluminum tape and tinned copper (TC) braid shielding provides enhanced protection against EMI and RFI, making it ideal for VFD applications where signal integrity is crucial.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003ePVC Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe PVC (Polyvinyl Chloride) jacket offers durability and resistance to environmental factors, making the cable suitable for both indoor and outdoor tray installations.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e600V Rating:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eWith a 600V rating, this cable can handle the voltage requirements of many VFD systems commonly used in industrial settings.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eNational Electrical Code (NEC):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor general electrical installation guidelines.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUL (Underwriters Laboratories):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eEnsuring safety and performance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIEEE Standards:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor specific applications like VFDs.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eLocal Electrical Codes:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eLocal regulations for compliance.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eConductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eflexible red copper conductor Cl. 5, acc. to IEC 60228, DIN VDE 0295 and UL standard 83\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eInsulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003efrom 18 AWG up to 16 AWG: GAALTHERM 520 from 14 AWG and over: GAALTHERM 591\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eCores color:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+3g..: 3 black conductors numbered + 3 green-yellow conductors divided in 3 inertstices 3x..+1g.. \/ 4g..+(2x..) or 4g..+(2x..+2x..): black cores with consecutive numbers acc. to EN 50334 + green\/yellow\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eStranding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+1g..: cores twisted together + fillers 3x..+3g..: phase units laid up with earth-conductors in interstices 4g..+(2x..) or 4g..+(2x..+2x..): control cores twisted in pair(s) and screened, supply cores and control screened pair(s) twisted together\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIndividual screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e4g..+(2x..) or 4g..+(2x..+2x..): aluminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOverall screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ealuminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOuter Sheath:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eblack (similar RAL 9005), GAALTHERM 520\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUV resistant\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eoutdoor use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003einstallation in hazardous areas\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 2277 WTTC or Flexible Motor Supply\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 1277 (Oil-resistant according to UL OIL RES I and Water-resistant, UL 90°C Dry or 90°C Wet )\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUL only for TC-ER use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request c(UL) type CIC\/TC FT4, AWM I\/II A\/B FT4\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request DIRECT BURIAL\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to to NFPA 79 2007 and NEC 336.10(7) Class 1, Div. 2 Art. 336, 392, 501\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for application acc. to EN 55011, DIN VDE 0875 and EN 61800-3\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for chain application, see technical data*\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eRoHS and CE approval\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• No. of cores x cross section n x AWG\/MCM:\u003c\/strong\u003e\u003cspan\u003e 4 G 350\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Outer Ø inches\/mm ±10%:\u003c\/strong\u003e\u003cspan\u003e 2,26 - 56,5\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Nominal voltage:\u003c\/strong\u003e\u003cspan\u003e UL 1277 TC-ER-600 V, UL 2277 WTTC \/ Flexible Motor Supply-1000 V, IEC: Uo\/U 600\/1000 V\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Temperature range UL:\u003cspan\u003e  \u003c\/span\u003e\u003c\/strong\u003eup to 90°C Fixed laying: - 40 oC up to + 105 oC Flexible installation: - 5 oC up to + 105 oC\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Min. bending radius:\u003c\/strong\u003e\u003cspan\u003e Fixed laying: 6 x d Flexible application: 20 x d\u003cbr\u003e\u003cstrong\u003e• Copper weight Lbs\/Mft:\u003c\/strong\u003e 5041,3\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Cable weight approx. Lbs\/Mft:\u003c\/strong\u003e\u003cspan\u003e 5999\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e\u003cspan\u003e 33290F70041A7C\u003c\/span\u003e\u003c\/p\u003e","brand":"Elettrotek Kabel","offers":[{"title":"Default Title","offer_id":44264409858202,"sku":"33290F70041A7C","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/308_e0c50771-2ad9-4cd6-a251-c57da6a1cdaa.png?v=1762987851"},{"product_id":"10-3c-18-3c-bare-copper-shielded-al-tape-tc-braid-pvc-gaalflex-tray-vfd-1405-600v-cable","title":"10\/3C+18\/3C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/F2143-American-Industrial-Mining-Cables_removed_7.pdf?v=1703677301\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e10\/3C+18\/3C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 10\/3C+18\/3C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Gaalflex Bare Copper Shielded Al Tape TC Braid PVC Tray VFD 1405 600V Cable is a specialized cable designed for use in various industrial applications. It features a construction that includes bare copper conductors, shielding with aluminum tape and TC (Tinned Copper) braid, and a PVC jacket.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eGaalflex VFD 1405 600V Cable specifications\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eBare Copper Shielded Al Tape TC Braid PVC Tray Cable\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eInstrumentation cable standards\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eTray cable applications and usage\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eVFD cable for motor drives\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eShielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThis cable is shielded, which means it provides protection against electromagnetic interference (EMI) and radio-frequency interference (RFI). This shielding ensures stable and reliable signal transmission, critical for VFD systems.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eBare Copper Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe use of bare copper conductors ensures excellent electrical conductivity, reducing energy losses and allowing for efficient power transmission.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eAluminum Tape and TC Braid Shielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe combination of aluminum tape and tinned copper (TC) braid shielding provides enhanced protection against EMI and RFI, making it ideal for VFD applications where signal integrity is crucial.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003ePVC Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe PVC (Polyvinyl Chloride) jacket offers durability and resistance to environmental factors, making the cable suitable for both indoor and outdoor tray installations.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e600V Rating:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eWith a 600V rating, this cable can handle the voltage requirements of many VFD systems commonly used in industrial settings.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eNational Electrical Code (NEC):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor general electrical installation guidelines.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUL (Underwriters Laboratories):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eEnsuring safety and performance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIEEE Standards:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor specific applications like VFDs.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eLocal Electrical Codes:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eLocal regulations for compliance.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eConductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eflexible red copper conductor Cl. 5, acc. to IEC 60228, DIN VDE 0295 and UL standard 83\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eInsulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003efrom 18 AWG up to 16 AWG: GAALTHERM 520 from 14 AWG and over: GAALTHERM 591\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eCores color:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+3g..: 3 black conductors numbered + 3 green-yellow conductors divided in 3 inertstices 3x..+1g.. \/ 4g..+(2x..) or 4g..+(2x..+2x..): black cores with consecutive numbers acc. to EN 50334 + green\/yellow\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eStranding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+1g..: cores twisted together + fillers 3x..+3g..: phase units laid up with earth-conductors in interstices 4g..+(2x..) or 4g..+(2x..+2x..): control cores twisted in pair(s) and screened, supply cores and control screened pair(s) twisted together\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIndividual screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e4g..+(2x..) or 4g..+(2x..+2x..): aluminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOverall screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ealuminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOuter Sheath:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eblack (similar RAL 9005), GAALTHERM 520\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUV resistant\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eoutdoor use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003einstallation in hazardous areas\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 2277 WTTC or Flexible Motor Supply\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 1277 (Oil-resistant according to UL OIL RES I and Water-resistant, UL 90°C Dry or 90°C Wet )\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUL only for TC-ER use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request c(UL) type CIC\/TC FT4, AWM I\/II A\/B FT4\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request DIRECT BURIAL\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to to NFPA 79 2007 and NEC 336.10(7) Class 1, Div. 2 Art. 336, 392, 501\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for application acc. to EN 55011, DIN VDE 0875 and EN 61800-3\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for chain application, see technical data*\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eRoHS and CE approval\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• No. of cores x cross section n x AWG\/MCM:\u003c\/strong\u003e\u003cspan\u003e 3 x 10 + 3 G 18\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Outer Ø inches\/mm ±10%:\u003c\/strong\u003e\u003cspan\u003e 0,608 - 15,2\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Nominal voltage:\u003c\/strong\u003e\u003cspan\u003e UL 1277 TC-ER-600 V, UL 2277 WTTC \/ Flexible Motor Supply-1000 V, IEC: Uo\/U 600\/1000 V\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Temperature range UL:\u003cspan\u003e  \u003c\/span\u003e\u003c\/strong\u003eup to 90°C Fixed laying: - 40 oC up to + 105 oC Flexible installation: - 5 oC up to + 105 oC\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Min. bending radius:\u003c\/strong\u003e\u003cspan\u003e Fixed laying: 6 x d Flexible application: 20 x d\u003cbr\u003e\u003cstrong\u003e• Copper weight Lbs\/Mft:\u003c\/strong\u003e 179,4\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Cable weight approx. Lbs\/Mft:\u003c\/strong\u003e\u003cspan\u003e 252\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e\u003cspan\u003e 33290F70037A10\u003c\/span\u003e\u003c\/p\u003e","brand":"Elettrotek Kabel","offers":[{"title":"Default Title","offer_id":44264411365530,"sku":"33290F70037A10","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/308_c2b57943-a8e5-47bd-a8c9-c621c99f382b.png?v=1762987851"},{"product_id":"8-3c-16-3c-bare-copper-shielded-al-tape-tc-braid-pvc-gaalflex-tray-vfd-1405-600v-cable","title":"8\/3C+16\/3C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/F2143-American-Industrial-Mining-Cables_removed_7.pdf?v=1703677301\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e8\/3C+16\/3C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 8\/3C+16\/3C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Gaalflex Bare Copper Shielded Al Tape TC Braid PVC Tray VFD 1405 600V Cable is a specialized cable designed for use in various industrial applications. It features a construction that includes bare copper conductors, shielding with aluminum tape and TC (Tinned Copper) braid, and a PVC jacket.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eGaalflex VFD 1405 600V Cable specifications\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eBare Copper Shielded Al Tape TC Braid PVC Tray Cable\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eInstrumentation cable standards\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eTray cable applications and usage\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eVFD cable for motor drives\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eShielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThis cable is shielded, which means it provides protection against electromagnetic interference (EMI) and radio-frequency interference (RFI). This shielding ensures stable and reliable signal transmission, critical for VFD systems.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eBare Copper Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe use of bare copper conductors ensures excellent electrical conductivity, reducing energy losses and allowing for efficient power transmission.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eAluminum Tape and TC Braid Shielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe combination of aluminum tape and tinned copper (TC) braid shielding provides enhanced protection against EMI and RFI, making it ideal for VFD applications where signal integrity is crucial.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003ePVC Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe PVC (Polyvinyl Chloride) jacket offers durability and resistance to environmental factors, making the cable suitable for both indoor and outdoor tray installations.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e600V Rating:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eWith a 600V rating, this cable can handle the voltage requirements of many VFD systems commonly used in industrial settings.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eNational Electrical Code (NEC):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor general electrical installation guidelines.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUL (Underwriters Laboratories):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eEnsuring safety and performance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIEEE Standards:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor specific applications like VFDs.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eLocal Electrical Codes:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eLocal regulations for compliance.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eConductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eflexible red copper conductor Cl. 5, acc. to IEC 60228, DIN VDE 0295 and UL standard 83\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eInsulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003efrom 18 AWG up to 16 AWG: GAALTHERM 520 from 14 AWG and over: GAALTHERM 591\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eCores color:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+3g..: 3 black conductors numbered + 3 green-yellow conductors divided in 3 inertstices 3x..+1g.. \/ 4g..+(2x..) or 4g..+(2x..+2x..): black cores with consecutive numbers acc. to EN 50334 + green\/yellow\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eStranding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+1g..: cores twisted together + fillers 3x..+3g..: phase units laid up with earth-conductors in interstices 4g..+(2x..) or 4g..+(2x..+2x..): control cores twisted in pair(s) and screened, supply cores and control screened pair(s) twisted together\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIndividual screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e4g..+(2x..) or 4g..+(2x..+2x..): aluminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOverall screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ealuminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOuter Sheath:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eblack (similar RAL 9005), GAALTHERM 520\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUV resistant\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eoutdoor use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003einstallation in hazardous areas\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 2277 WTTC or Flexible Motor Supply\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 1277 (Oil-resistant according to UL OIL RES I and Water-resistant, UL 90°C Dry or 90°C Wet )\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUL only for TC-ER use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request c(UL) type CIC\/TC FT4, AWM I\/II A\/B FT4\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request DIRECT BURIAL\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to to NFPA 79 2007 and NEC 336.10(7) Class 1, Div. 2 Art. 336, 392, 501\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for application acc. to EN 55011, DIN VDE 0875 and EN 61800-3\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for chain application, see technical data*\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eRoHS and CE approval\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• No. of cores x cross section n x AWG\/MCM:\u003c\/strong\u003e\u003cspan\u003e 3 x 8 + 3 G 16\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Outer Ø inches\/mm ±10%:\u003c\/strong\u003e\u003cspan\u003e 0,724 - 18,1\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Nominal voltage:\u003c\/strong\u003e\u003cspan\u003e UL 1277 TC-ER-600 V, UL 2277 WTTC \/ Flexible Motor Supply-1000 V, IEC: Uo\/U 600\/1000 V\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Temperature range UL:\u003cspan\u003e  \u003c\/span\u003e\u003c\/strong\u003eup to 90°C Fixed laying: - 40 oC up to + 105 oC Flexible installation: - 5 oC up to + 105 oC\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Min. bending radius:\u003c\/strong\u003e\u003cspan\u003e Fixed laying: 6 x d Flexible application: 20 x d\u003cbr\u003e\u003cstrong\u003e• Copper weight Lbs\/Mft:\u003c\/strong\u003e 277,5\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Cable weight approx. Lbs\/Mft:\u003c\/strong\u003e\u003cspan\u003e 378,3 \u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e\u003cspan\u003e 33290F70037A08\u003c\/span\u003e\u003c\/p\u003e","brand":"Elettrotek Kabel","offers":[{"title":"Default Title","offer_id":44264412512410,"sku":"33290F70037A08","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/308_d2e2e683-637e-492a-b5d9-296edec61ade.png?v=1762987852"},{"product_id":"6-3c-14-3c-bare-copper-shielded-al-tape-tc-braid-pvc-gaalflex-tray-vfd-1405-600v-cable","title":"6\/3C+14\/3C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/F2143-American-Industrial-Mining-Cables_removed_7.pdf?v=1703677301\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e6\/3C+14\/3C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 6\/3C+14\/3C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Gaalflex Bare Copper Shielded Al Tape TC Braid PVC Tray VFD 1405 600V Cable is a specialized cable designed for use in various industrial applications. It features a construction that includes bare copper conductors, shielding with aluminum tape and TC (Tinned Copper) braid, and a PVC jacket.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eGaalflex VFD 1405 600V Cable specifications\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eBare Copper Shielded Al Tape TC Braid PVC Tray Cable\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eInstrumentation cable standards\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eTray cable applications and usage\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eVFD cable for motor drives\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eShielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThis cable is shielded, which means it provides protection against electromagnetic interference (EMI) and radio-frequency interference (RFI). This shielding ensures stable and reliable signal transmission, critical for VFD systems.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eBare Copper Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe use of bare copper conductors ensures excellent electrical conductivity, reducing energy losses and allowing for efficient power transmission.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eAluminum Tape and TC Braid Shielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe combination of aluminum tape and tinned copper (TC) braid shielding provides enhanced protection against EMI and RFI, making it ideal for VFD applications where signal integrity is crucial.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003ePVC Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe PVC (Polyvinyl Chloride) jacket offers durability and resistance to environmental factors, making the cable suitable for both indoor and outdoor tray installations.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e600V Rating:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eWith a 600V rating, this cable can handle the voltage requirements of many VFD systems commonly used in industrial settings.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eNational Electrical Code (NEC):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor general electrical installation guidelines.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUL (Underwriters Laboratories):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eEnsuring safety and performance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIEEE Standards:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor specific applications like VFDs.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eLocal Electrical Codes:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eLocal regulations for compliance.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eConductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eflexible red copper conductor Cl. 5, acc. to IEC 60228, DIN VDE 0295 and UL standard 83\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eInsulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003efrom 18 AWG up to 16 AWG: GAALTHERM 520 from 14 AWG and over: GAALTHERM 591\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eCores color:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+3g..: 3 black conductors numbered + 3 green-yellow conductors divided in 3 inertstices 3x..+1g.. \/ 4g..+(2x..) or 4g..+(2x..+2x..): black cores with consecutive numbers acc. to EN 50334 + green\/yellow\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eStranding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+1g..: cores twisted together + fillers 3x..+3g..: phase units laid up with earth-conductors in interstices 4g..+(2x..) or 4g..+(2x..+2x..): control cores twisted in pair(s) and screened, supply cores and control screened pair(s) twisted together\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIndividual screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e4g..+(2x..) or 4g..+(2x..+2x..): aluminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOverall screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ealuminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOuter Sheath:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eblack (similar RAL 9005), GAALTHERM 520\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUV resistant\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eoutdoor use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003einstallation in hazardous areas\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 2277 WTTC or Flexible Motor Supply\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 1277 (Oil-resistant according to UL OIL RES I and Water-resistant, UL 90°C Dry or 90°C Wet )\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUL only for TC-ER use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request c(UL) type CIC\/TC FT4, AWM I\/II A\/B FT4\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request DIRECT BURIAL\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to to NFPA 79 2007 and NEC 336.10(7) Class 1, Div. 2 Art. 336, 392, 501\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for application acc. to EN 55011, DIN VDE 0875 and EN 61800-3\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for chain application, see technical data*\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eRoHS and CE approval\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• No. of cores x cross section n x AWG\/MCM:\u003c\/strong\u003e\u003cspan\u003e 3 x 6 + 3 G 14\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Outer Ø inches\/mm ±10%:\u003c\/strong\u003e\u003cspan\u003e 0,804 - 20,1\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Nominal voltage:\u003c\/strong\u003e\u003cspan\u003e UL 1277 TC-ER-600 V, UL 2277 WTTC \/ Flexible Motor Supply-1000 V, IEC: Uo\/U 600\/1000 V\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Temperature range UL:\u003cspan\u003e  \u003c\/span\u003e\u003c\/strong\u003eup to 90°C Fixed laying: - 40 oC up to + 105 oC Flexible installation: - 5 oC up to + 105 oC\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Min. bending radius:\u003c\/strong\u003e\u003cspan\u003e Fixed laying: 6 x d Flexible application: 20 x d\u003cbr\u003e\u003cstrong\u003e• Copper weight Lbs\/Mft:\u003c\/strong\u003e 428,7\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Cable weight approx. Lbs\/Mft:\u003c\/strong\u003e\u003cspan\u003e 552,4\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e\u003cspan\u003e 33290F70037A06\u003c\/span\u003e\u003c\/p\u003e","brand":"Elettrotek Kabel","offers":[{"title":"Default Title","offer_id":44264416313498,"sku":"33290F70037A06","price":11.38,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/308_b7dead03-c92e-4867-897a-7e5269d5d26a.png?v=1759825839"},{"product_id":"4-3c-12-3c-bare-copper-shielded-al-tape-tc-braid-pvc-gaalflex-tray-vfd-1405-600v-cable","title":"4\/3C+12\/3C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/F2143-American-Industrial-Mining-Cables_removed_7.pdf?v=1703677301\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e4\/3C+12\/3C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 4\/3C+12\/3C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Gaalflex Bare Copper Shielded Al Tape TC Braid PVC Tray VFD 1405 600V Cable is a specialized cable designed for use in various industrial applications. It features a construction that includes bare copper conductors, shielding with aluminum tape and TC (Tinned Copper) braid, and a PVC jacket.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eGaalflex VFD 1405 600V Cable specifications\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eBare Copper Shielded Al Tape TC Braid PVC Tray Cable\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eInstrumentation cable standards\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eTray cable applications and usage\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eVFD cable for motor drives\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eShielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThis cable is shielded, which means it provides protection against electromagnetic interference (EMI) and radio-frequency interference (RFI). This shielding ensures stable and reliable signal transmission, critical for VFD systems.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eBare Copper Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe use of bare copper conductors ensures excellent electrical conductivity, reducing energy losses and allowing for efficient power transmission.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eAluminum Tape and TC Braid Shielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe combination of aluminum tape and tinned copper (TC) braid shielding provides enhanced protection against EMI and RFI, making it ideal for VFD applications where signal integrity is crucial.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003ePVC Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe PVC (Polyvinyl Chloride) jacket offers durability and resistance to environmental factors, making the cable suitable for both indoor and outdoor tray installations.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e600V Rating:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eWith a 600V rating, this cable can handle the voltage requirements of many VFD systems commonly used in industrial settings.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eNational Electrical Code (NEC):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor general electrical installation guidelines.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUL (Underwriters Laboratories):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eEnsuring safety and performance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIEEE Standards:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor specific applications like VFDs.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eLocal Electrical Codes:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eLocal regulations for compliance.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eConductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eflexible red copper conductor Cl. 5, acc. to IEC 60228, DIN VDE 0295 and UL standard 83\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eInsulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003efrom 18 AWG up to 16 AWG: GAALTHERM 520 from 14 AWG and over: GAALTHERM 591\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eCores color:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+3g..: 3 black conductors numbered + 3 green-yellow conductors divided in 3 inertstices 3x..+1g.. \/ 4g..+(2x..) or 4g..+(2x..+2x..): black cores with consecutive numbers acc. to EN 50334 + green\/yellow\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eStranding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+1g..: cores twisted together + fillers 3x..+3g..: phase units laid up with earth-conductors in interstices 4g..+(2x..) or 4g..+(2x..+2x..): control cores twisted in pair(s) and screened, supply cores and control screened pair(s) twisted together\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIndividual screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e4g..+(2x..) or 4g..+(2x..+2x..): aluminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOverall screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ealuminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOuter Sheath:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eblack (similar RAL 9005), GAALTHERM 520\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUV resistant\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eoutdoor use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003einstallation in hazardous areas\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 2277 WTTC or Flexible Motor Supply\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 1277 (Oil-resistant according to UL OIL RES I and Water-resistant, UL 90°C Dry or 90°C Wet )\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUL only for TC-ER use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request c(UL) type CIC\/TC FT4, AWM I\/II A\/B FT4\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request DIRECT BURIAL\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to to NFPA 79 2007 and NEC 336.10(7) Class 1, Div. 2 Art. 336, 392, 501\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for application acc. to EN 55011, DIN VDE 0875 and EN 61800-3\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for chain application, see technical data*\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eRoHS and CE approval\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• No. of cores x cross section n x AWG\/MCM:\u003c\/strong\u003e\u003cspan\u003e 3 x 4 + 3 G 12\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Outer Ø inches\/mm ±10%:\u003c\/strong\u003e\u003cspan\u003e 0,976 - 24,4\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Nominal voltage:\u003c\/strong\u003e\u003cspan\u003e UL 1277 TC-ER-600 V, UL 2277 WTTC \/ Flexible Motor Supply-1000 V, IEC: Uo\/U 600\/1000 V\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Temperature range UL:\u003cspan\u003e  \u003c\/span\u003e\u003c\/strong\u003eup to 90°C Fixed laying: - 40 oC up to + 105 oC Flexible installation: - 5 oC up to + 105 oC\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Min. bending radius:\u003c\/strong\u003e\u003cspan\u003e Fixed laying: 6 x d Flexible application: 20 x d\u003cbr\u003e\u003cstrong\u003e• Copper weight Lbs\/Mft:\u003c\/strong\u003e 643,8\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Cable weight approx. Lbs\/Mft:\u003c\/strong\u003e\u003cspan\u003e 824,5\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e\u003cspan\u003e 33290F70037A04\u003c\/span\u003e\u003c\/p\u003e","brand":"Elettrotek Kabel","offers":[{"title":"Default Title","offer_id":44265875996826,"sku":"33290F70037A04","price":16.17,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/308_9c986aa6-218f-4f2a-ad7d-e36a99690210.png?v=1762987888"},{"product_id":"2-3c-10-3c-bare-copper-shielded-al-tape-tc-braid-pvc-gaalflex-tray-vfd-1405-600v-cable","title":"2\/3C+10\/3C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/F2143-American-Industrial-Mining-Cables_removed_7.pdf?v=1703677301\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e2\/3C+10\/3C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 2\/3C+10\/3C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Gaalflex Bare Copper Shielded Al Tape TC Braid PVC Tray VFD 1405 600V Cable is a specialized cable designed for use in various industrial applications. It features a construction that includes bare copper conductors, shielding with aluminum tape and TC (Tinned Copper) braid, and a PVC jacket.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eGaalflex VFD 1405 600V Cable specifications\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eBare Copper Shielded Al Tape TC Braid PVC Tray Cable\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eInstrumentation cable standards\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eTray cable applications and usage\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eVFD cable for motor drives\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eShielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThis cable is shielded, which means it provides protection against electromagnetic interference (EMI) and radio-frequency interference (RFI). This shielding ensures stable and reliable signal transmission, critical for VFD systems.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eBare Copper Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe use of bare copper conductors ensures excellent electrical conductivity, reducing energy losses and allowing for efficient power transmission.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eAluminum Tape and TC Braid Shielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe combination of aluminum tape and tinned copper (TC) braid shielding provides enhanced protection against EMI and RFI, making it ideal for VFD applications where signal integrity is crucial.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003ePVC Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe PVC (Polyvinyl Chloride) jacket offers durability and resistance to environmental factors, making the cable suitable for both indoor and outdoor tray installations.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e600V Rating:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eWith a 600V rating, this cable can handle the voltage requirements of many VFD systems commonly used in industrial settings.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eNational Electrical Code (NEC):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor general electrical installation guidelines.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUL (Underwriters Laboratories):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eEnsuring safety and performance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIEEE Standards:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor specific applications like VFDs.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eLocal Electrical Codes:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eLocal regulations for compliance.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eConductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eflexible red copper conductor Cl. 5, acc. to IEC 60228, DIN VDE 0295 and UL standard 83\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eInsulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003efrom 18 AWG up to 16 AWG: GAALTHERM 520 from 14 AWG and over: GAALTHERM 591\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eCores color:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+3g..: 3 black conductors numbered + 3 green-yellow conductors divided in 3 inertstices 3x..+1g.. \/ 4g..+(2x..) or 4g..+(2x..+2x..): black cores with consecutive numbers acc. to EN 50334 + green\/yellow\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eStranding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+1g..: cores twisted together + fillers 3x..+3g..: phase units laid up with earth-conductors in interstices 4g..+(2x..) or 4g..+(2x..+2x..): control cores twisted in pair(s) and screened, supply cores and control screened pair(s) twisted together\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIndividual screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e4g..+(2x..) or 4g..+(2x..+2x..): aluminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOverall screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ealuminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOuter Sheath:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eblack (similar RAL 9005), GAALTHERM 520\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUV resistant\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eoutdoor use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003einstallation in hazardous areas\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 2277 WTTC or Flexible Motor Supply\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 1277 (Oil-resistant according to UL OIL RES I and Water-resistant, UL 90°C Dry or 90°C Wet )\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUL only for TC-ER use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request c(UL) type CIC\/TC FT4, AWM I\/II A\/B FT4\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request DIRECT BURIAL\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to to NFPA 79 2007 and NEC 336.10(7) Class 1, Div. 2 Art. 336, 392, 501\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for application acc. to EN 55011, DIN VDE 0875 and EN 61800-3\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for chain application, see technical data*\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eRoHS and CE approval\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• No. of cores x cross section n x AWG\/MCM:\u003c\/strong\u003e\u003cspan\u003e 3 x 2 + 3 G 10\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Outer Ø inches\/mm ±10%:\u003c\/strong\u003e\u003cspan\u003e 1,08 - 27\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Nominal voltage:\u003c\/strong\u003e\u003cspan\u003e UL 1277 TC-ER-600 V, UL 2277 WTTC \/ Flexible Motor Supply-1000 V, IEC: Uo\/U 600\/1000 V\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Temperature range UL:\u003cspan\u003e  \u003c\/span\u003e\u003c\/strong\u003eup to 90°C Fixed laying: - 40 oC up to + 105 oC Flexible installation: - 5 oC up to + 105 oC\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Min. bending radius:\u003c\/strong\u003e\u003cspan\u003e Fixed laying: 6 x d Flexible application: 20 x d\u003cbr\u003e\u003cstrong\u003e• Copper weight Lbs\/Mft:\u003c\/strong\u003e 887,7\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Cable weight approx. Lbs\/Mft:\u003c\/strong\u003e\u003cspan\u003e 1077,9\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e\u003cspan\u003e 33290F70037A02\u003c\/span\u003e\u003c\/p\u003e","brand":"Elettrotek Kabel","offers":[{"title":"Default Title","offer_id":44265883107482,"sku":"33290F70037A02","price":21.16,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/308_c4608f0c-3a3b-4697-b630-4ceee2382350.png?v=1759825843"},{"product_id":"1-3c-8-3c-bare-copper-shielded-al-tape-tc-braid-pvc-gaalflex-tray-vfd-1405-600v-cable","title":"1\/3C+8\/3C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/F2143-American-Industrial-Mining-Cables_removed_7.pdf?v=1703677301\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e1\/3C+8\/3C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 1\/3C+8\/3C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Gaalflex Bare Copper Shielded Al Tape TC Braid PVC Tray VFD 1405 600V Cable is a specialized cable designed for use in various industrial applications. It features a construction that includes bare copper conductors, shielding with aluminum tape and TC (Tinned Copper) braid, and a PVC jacket.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eGaalflex VFD 1405 600V Cable specifications\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eBare Copper Shielded Al Tape TC Braid PVC Tray Cable\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eInstrumentation cable standards\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eTray cable applications and usage\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eVFD cable for motor drives\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eShielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThis cable is shielded, which means it provides protection against electromagnetic interference (EMI) and radio-frequency interference (RFI). This shielding ensures stable and reliable signal transmission, critical for VFD systems.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eBare Copper Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe use of bare copper conductors ensures excellent electrical conductivity, reducing energy losses and allowing for efficient power transmission.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eAluminum Tape and TC Braid Shielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe combination of aluminum tape and tinned copper (TC) braid shielding provides enhanced protection against EMI and RFI, making it ideal for VFD applications where signal integrity is crucial.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003ePVC Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe PVC (Polyvinyl Chloride) jacket offers durability and resistance to environmental factors, making the cable suitable for both indoor and outdoor tray installations.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e600V Rating:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eWith a 600V rating, this cable can handle the voltage requirements of many VFD systems commonly used in industrial settings.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eNational Electrical Code (NEC):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor general electrical installation guidelines.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUL (Underwriters Laboratories):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eEnsuring safety and performance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIEEE Standards:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor specific applications like VFDs.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eLocal Electrical Codes:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eLocal regulations for compliance.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eConductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eflexible red copper conductor Cl. 5, acc. to IEC 60228, DIN VDE 0295 and UL standard 83\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eInsulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003efrom 18 AWG up to 16 AWG: GAALTHERM 520 from 14 AWG and over: GAALTHERM 591\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eCores color:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+3g..: 3 black conductors numbered + 3 green-yellow conductors divided in 3 inertstices 3x..+1g.. \/ 4g..+(2x..) or 4g..+(2x..+2x..): black cores with consecutive numbers acc. to EN 50334 + green\/yellow\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eStranding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+1g..: cores twisted together + fillers 3x..+3g..: phase units laid up with earth-conductors in interstices 4g..+(2x..) or 4g..+(2x..+2x..): control cores twisted in pair(s) and screened, supply cores and control screened pair(s) twisted together\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIndividual screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e4g..+(2x..) or 4g..+(2x..+2x..): aluminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOverall screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ealuminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOuter Sheath:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eblack (similar RAL 9005), GAALTHERM 520\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUV resistant\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eoutdoor use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003einstallation in hazardous areas\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 2277 WTTC or Flexible Motor Supply\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 1277 (Oil-resistant according to UL OIL RES I and Water-resistant, UL 90°C Dry or 90°C Wet )\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUL only for TC-ER use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request c(UL) type CIC\/TC FT4, AWM I\/II A\/B FT4\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request DIRECT BURIAL\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to to NFPA 79 2007 and NEC 336.10(7) Class 1, Div. 2 Art. 336, 392, 501\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for application acc. to EN 55011, DIN VDE 0875 and EN 61800-3\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for chain application, see technical data*\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eRoHS and CE approval\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• No. of cores x cross section n x AWG\/MCM:\u003c\/strong\u003e 3 x 1 + 3 G 8\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Outer Ø inches\/mm ±10%:\u003c\/strong\u003e\u003cspan\u003e 1,28 - 32\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Nominal voltage:\u003c\/strong\u003e\u003cspan\u003e UL 1277 TC-ER-600 V, UL 2277 WTTC \/ Flexible Motor Supply-1000 V, IEC: Uo\/U 600\/1000 V\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Temperature range UL:\u003cspan\u003e  \u003c\/span\u003e\u003c\/strong\u003eup to 90°C Fixed laying: - 40 oC up to + 105 oC Flexible installation: - 5 oC up to + 105 oC\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Min. bending radius:\u003c\/strong\u003e\u003cspan\u003e Fixed laying: 6 x d Flexible application: 20 x d\u003cbr\u003e\u003cstrong\u003e• Copper weight Lbs\/Mft:\u003c\/strong\u003e 1308,4\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Cable weight approx. Lbs\/Mft:\u003c\/strong\u003e\u003cspan\u003e 1560,4\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e\u003cspan\u003e 33290F70037A01\u003c\/span\u003e\u003c\/p\u003e","brand":"Elettrotek Kabel","offers":[{"title":"Default Title","offer_id":44265889038490,"sku":"33290F70037A01","price":30.73,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/308_f4720a19-ca10-46c9-9655-1134b0600d0d.png?v=1762987891"},{"product_id":"1-0-3c-10-3c-bare-copper-shielded-al-tape-tc-braid-pvc-gaalflex-tray-vfd-1405-600v-cable","title":"1\/0-3C+10\/3C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/F2143-American-Industrial-Mining-Cables_removed_7.pdf?v=1703677301\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e1\/0-3C+10\/3C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 1\/0-3C+10\/3C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Gaalflex Bare Copper Shielded Al Tape TC Braid PVC Tray VFD 1405 600V Cable is a specialized cable designed for use in various industrial applications. It features a construction that includes bare copper conductors, shielding with aluminum tape and TC (Tinned Copper) braid, and a PVC jacket.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eGaalflex VFD 1405 600V Cable specifications\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eBare Copper Shielded Al Tape TC Braid PVC Tray Cable\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eInstrumentation cable standards\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eTray cable applications and usage\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eVFD cable for motor drives\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eShielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThis cable is shielded, which means it protects against electromagnetic interference (EMI) and radio-frequency interference (RFI). This shielding ensures stable and reliable signal transmission, critical for VFD systems.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eBare Copper Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe use of bare copper conductors ensures excellent electrical conductivity, reducing energy losses and allowing for efficient power transmission.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eAluminum Tape and TC Braid Shielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe combination of aluminum tape and tinned copper (TC) braid shielding provides enhanced protection against EMI and RFI, making it ideal for VFD applications where signal integrity is crucial.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003ePVC Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe PVC (Polyvinyl Chloride) jacket offers durability and resistance to environmental factors, making the cable suitable for both indoor and outdoor tray installations.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e600V Rating:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eWith a 600V rating, this cable can handle the voltage requirements of many VFD systems commonly used in industrial settings.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eNational Electrical Code (NEC):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor general electrical installation guidelines.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUL (Underwriters Laboratories):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eEnsuring safety and performance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIEEE Standards:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor specific applications like VFDs.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eLocal Electrical Codes:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eLocal regulations for compliance.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eConductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eflexible red copper conductor Cl. 5, acc. to IEC 60228, DIN VDE 0295 and UL standard 83\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eInsulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003efrom 18 AWG up to 16 AWG: GAALTHERM 520 from 14 AWG and over: GAALTHERM 591\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eCores color:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+3g..: 3 black conductors numbered + 3 green-yellow conductors divided in 3 inertstices 3x..+1g.. \/ 4g..+(2x..) or 4g..+(2x..+2x..): black cores with consecutive numbers acc. to EN 50334 + green\/yellow\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eStranding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+1g..: cores twisted together + fillers 3x..+3g..: phase units laid up with earth-conductors in interstices 4g..+(2x..) or 4g..+(2x..+2x..): control cores twisted in pair(s) and screened, supply cores and control screened pair(s) twisted together\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIndividual screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e4g..+(2x..) or 4g..+(2x..+2x..): aluminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOverall screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ealuminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOuter Sheath:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eblack (similar RAL 9005), GAALTHERM 520\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUV resistant\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eoutdoor use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003einstallation in hazardous areas\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 2277 WTTC or Flexible Motor Supply\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 1277 (Oil-resistant according to UL OIL RES I and Water-resistant, UL 90°C Dry or 90°C Wet )\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUL only for TC-ER use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request c(UL) type CIC\/TC FT4, AWM I\/II A\/B FT4\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request DIRECT BURIAL\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to NFPA 79 2007 and NEC 336.10(7) Class 1, Div. 2 Art. 336, 392, 501\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for application acc. to EN 55011, DIN VDE 0875 and EN 61800-3\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for chain application, see technical data*\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eRoHS and CE approval\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• No. of cores x cross section n x AWG\/MCM:\u003c\/strong\u003e 3 x 1\/0 + 3 G 10\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Outer Ø inches\/mm ±10%:\u003c\/strong\u003e\u003cspan\u003e 1,295 - 32,9\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Nominal voltage:\u003c\/strong\u003e\u003cspan\u003e UL 1277 TC-ER-600 V, UL 2277 WTTC \/ Flexible Motor Supply-1000 V, IEC: Uo\/U 600\/1000 V\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Temperature range UL:\u003cspan\u003e  \u003c\/span\u003e\u003c\/strong\u003eup to 90°C Fixed laying: - 40 oC up to + 105 oC Flexible installation: - 5 oC up to + 105 oC\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Min. bending radius:\u003c\/strong\u003e\u003cspan\u003e Fixed laying: 6 x d Flexible application: 20 x d\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Cable weight approx. Lbs\/Mft:\u003c\/strong\u003e\u003cspan\u003e 1669\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e\u003cspan\u003e 33290F70037A1C\u003c\/span\u003e\u003c\/p\u003e","brand":"Elettrotek Kabel","offers":[{"title":"Default Title","offer_id":44265893101722,"sku":"33290F70037A1C","price":35.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/308_f0dc8b2c-9f5f-4319-bb0d-03655db2e65d.png?v=1762987892"},{"product_id":"2-0-3c-8-3c-bare-copper-shielded-al-tape-tc-braid-pvc-gaalflex-tray-vfd-1405-600v-cable","title":"2\/0-3C+8\/3C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/F2143-American-Industrial-Mining-Cables_removed_7.pdf?v=1703677301\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e2\/0-3C+8\/3C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 2\/0-3C+8\/3C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Gaalflex Bare Copper Shielded Al Tape TC Braid PVC Tray VFD 1405 600V Cable is a specialized cable designed for use in various industrial applications. It features a construction that includes bare copper conductors, shielding with aluminum tape and TC (Tinned Copper) braid, and a PVC jacket.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eGaalflex VFD 1405 600V Cable specifications\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eBare Copper Shielded Al Tape TC Braid PVC Tray Cable\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eInstrumentation cable standards\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eTray cable applications and usage\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eVFD cable for motor drives\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eShielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThis cable is shielded, which means it provides protection against electromagnetic interference (EMI) and radio-frequency interference (RFI). This shielding ensures stable and reliable signal transmission, critical for VFD systems.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eBare Copper Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe use of bare copper conductors ensures excellent electrical conductivity, reducing energy losses and allowing for efficient power transmission.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eAluminum Tape and TC Braid Shielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe combination of aluminum tape and tinned copper (TC) braid shielding provides enhanced protection against EMI and RFI, making it ideal for VFD applications where signal integrity is crucial.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003ePVC Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe PVC (Polyvinyl Chloride) jacket offers durability and resistance to environmental factors, making the cable suitable for both indoor and outdoor tray installations.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e600V Rating:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eWith a 600V rating, this cable can handle the voltage requirements of many VFD systems commonly used in industrial settings.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eNational Electrical Code (NEC):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor general electrical installation guidelines.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUL (Underwriters Laboratories):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eEnsuring safety and performance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIEEE Standards:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor specific applications like VFDs.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eLocal Electrical Codes:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eLocal regulations for compliance.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eConductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eflexible red copper conductor Cl. 5, acc. to IEC 60228, DIN VDE 0295 and UL standard 83\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eInsulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003efrom 18 AWG up to 16 AWG: GAALTHERM 520 from 14 AWG and over: GAALTHERM 591\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eCores color:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+3g..: 3 black conductors numbered + 3 green-yellow conductors divided in 3 inertstices 3x..+1g.. \/ 4g..+(2x..) or 4g..+(2x..+2x..): black cores with consecutive numbers acc. to EN 50334 + green\/yellow\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eStranding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+1g..: cores twisted together + fillers 3x..+3g..: phase units laid up with earth-conductors in interstices 4g..+(2x..) or 4g..+(2x..+2x..): control cores twisted in pair(s) and screened, supply cores and control screened pair(s) twisted together\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIndividual screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e4g..+(2x..) or 4g..+(2x..+2x..): aluminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOverall screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ealuminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOuter Sheath:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eblack (similar RAL 9005), GAALTHERM 520\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUV resistant\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eoutdoor use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003einstallation in hazardous areas\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 2277 WTTC or Flexible Motor Supply\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 1277 (Oil-resistant according to UL OIL RES I and Water-resistant, UL 90°C Dry or 90°C Wet )\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUL only for TC-ER use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request c(UL) type CIC\/TC FT4, AWM I\/II A\/B FT4\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request DIRECT BURIAL\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to to NFPA 79 2007 and NEC 336.10(7) Class 1, Div. 2 Art. 336, 392, 501\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for application acc. to EN 55011, DIN VDE 0875 and EN 61800-3\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for chain application, see technical data*\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eRoHS and CE approval\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• No. of cores x cross section n x AWG\/MCM:\u003c\/strong\u003e 3 x 2\/0 + 3 G 8\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Outer Ø inches\/mm ±10%:\u003c\/strong\u003e\u003cspan\u003e 1,46 - 36,5\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Nominal voltage:\u003c\/strong\u003e\u003cspan\u003e UL 1277 TC-ER-600 V, UL 2277 WTTC \/ Flexible Motor Supply-1000 V, IEC: Uo\/U 600\/1000 V\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Temperature range UL:\u003cspan\u003e  \u003c\/span\u003e\u003c\/strong\u003eup to 90°C Fixed laying: - 40 oC up to + 105 oC Flexible installation: - 5 oC up to + 105 oC\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Min. bending radius:\u003c\/strong\u003e\u003cspan\u003e Fixed laying: 6 x d Flexible application: 20 x d\u003cbr\u003e\u003cstrong\u003e• Copper weight Lbs\/Mf: \u003c\/strong\u003e1714,3\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Cable weight approx. Lbs\/Mft:\u003c\/strong\u003e\u003cspan\u003e 1992,5\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e\u003cspan\u003e 33290F70037A2C\u003c\/span\u003e\u003c\/p\u003e","brand":"Elettrotek Kabel","offers":[{"title":"Default Title","offer_id":44265894281370,"sku":"33290F70037A2C","price":40.05,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/308_6a024148-5053-43c0-bac8-e390baedb68f.png?v=1762987894"},{"product_id":"3-0-3c-6-3c-bare-copper-shielded-al-tape-tc-braid-pvc-gaalflex-tray-vfd-1405-600v-cable","title":"3\/0-3C+6\/3C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/F2143-American-Industrial-Mining-Cables_removed_7.pdf?v=1703677301\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e3\/0-3C+6\/3C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 3\/0-3C+6\/3C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Gaalflex Bare Copper Shielded Al Tape TC Braid PVC Tray VFD 1405 600V Cable is a specialized cable designed for use in various industrial applications. It features a construction that includes bare copper conductors, shielding with aluminum tape and TC (Tinned Copper) braid, and a PVC jacket.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eGaalflex VFD 1405 600V Cable specifications\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eBare Copper Shielded Al Tape TC Braid PVC Tray Cable\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eInstrumentation cable standards\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eTray cable applications and usage\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eVFD cable for motor drives\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eShielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThis cable is shielded, which means it provides protection against electromagnetic interference (EMI) and radio-frequency interference (RFI). This shielding ensures stable and reliable signal transmission, critical for VFD systems.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eBare Copper Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe use of bare copper conductors ensures excellent electrical conductivity, reducing energy losses and allowing for efficient power transmission.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eAluminum Tape and TC Braid Shielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe combination of aluminum tape and tinned copper (TC) braid shielding provides enhanced protection against EMI and RFI, making it ideal for VFD applications where signal integrity is crucial.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003ePVC Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe PVC (Polyvinyl Chloride) jacket offers durability and resistance to environmental factors, making the cable suitable for both indoor and outdoor tray installations.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e600V Rating:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eWith a 600V rating, this cable can handle the voltage requirements of many VFD systems commonly used in industrial settings.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eNational Electrical Code (NEC):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor general electrical installation guidelines.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUL (Underwriters Laboratories):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eEnsuring safety and performance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIEEE Standards:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor specific applications like VFDs.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eLocal Electrical Codes:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eLocal regulations for compliance.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eConductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eflexible red copper conductor Cl. 5, acc. to IEC 60228, DIN VDE 0295 and UL standard 83\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eInsulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003efrom 18 AWG up to 16 AWG: GAALTHERM 520 from 14 AWG and over: GAALTHERM 591\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eCores color:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+3g..: 3 black conductors numbered + 3 green-yellow conductors divided in 3 inertstices 3x..+1g.. \/ 4g..+(2x..) or 4g..+(2x..+2x..): black cores with consecutive numbers acc. to EN 50334 + green\/yellow\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eStranding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+1g..: cores twisted together + fillers 3x..+3g..: phase units laid up with earth-conductors in interstices 4g..+(2x..) or 4g..+(2x..+2x..): control cores twisted in pair(s) and screened, supply cores and control screened pair(s) twisted together\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIndividual screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e4g..+(2x..) or 4g..+(2x..+2x..): aluminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOverall screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ealuminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOuter Sheath:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eblack (similar RAL 9005), GAALTHERM 520\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUV resistant\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eoutdoor use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003einstallation in hazardous areas\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 2277 WTTC or Flexible Motor Supply\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 1277 (Oil-resistant according to UL OIL RES I and Water-resistant, UL 90°C Dry or 90°C Wet )\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUL only for TC-ER use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request c(UL) type CIC\/TC FT4, AWM I\/II A\/B FT4\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request DIRECT BURIAL\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to to NFPA 79 2007 and NEC 336.10(7) Class 1, Div. 2 Art. 336, 392, 501\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for application acc. to EN 55011, DIN VDE 0875 and EN 61800-3\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for chain application, see technical data*\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eRoHS and CE approval\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• No. of cores x cross section n x AWG\/MCM:\u003c\/strong\u003e 3 x 3\/0 + 3 G 6\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Outer Ø inches\/mm ±10%:\u003c\/strong\u003e\u003cspan\u003e 1,592 - 39,8\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Nominal voltage:\u003c\/strong\u003e\u003cspan\u003e UL 1277 TC-ER-600 V, UL 2277 WTTC \/ Flexible Motor Supply-1000 V, IEC: Uo\/U 600\/1000 V\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Temperature range UL:\u003cspan\u003e  \u003c\/span\u003e\u003c\/strong\u003eup to 90°C Fixed laying: - 40 oC up to + 105 oC Flexible installation: - 5 oC up to + 105 oC\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Min. bending radius:\u003c\/strong\u003e\u003cspan\u003e Fixed laying: 6 x d Flexible application: 20 x d\u003cbr\u003e\u003cstrong\u003e• Copper weight Lbs\/Mf: \u003c\/strong\u003e2332,5\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Cable weight approx. Lbs\/Mft:\u003c\/strong\u003e\u003cspan\u003e 2598\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e\u003cspan\u003e 33290F70037A3C\u003c\/span\u003e\u003c\/p\u003e","brand":"Elettrotek Kabel","offers":[{"title":"Default Title","offer_id":44265897885850,"sku":"33290F70037A3C","price":54.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/308_92d1e3f1-a8dd-4177-93ab-db0a35d4d791.png?v=1762987895"},{"product_id":"4-0-3c-6-3c-bare-copper-shielded-al-tape-tc-braid-pvc-gaalflex-tray-vfd-1405-600v-cable","title":"4\/0-3C+6\/3C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/F2143-American-Industrial-Mining-Cables_removed_7.pdf?v=1703677301\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e4\/0-3C+6\/3C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 4\/0-3C+6\/3C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Gaalflex Bare Copper Shielded Al Tape TC Braid PVC Tray VFD 1405 600V Cable is a specialized cable designed for use in various industrial applications. It features a construction that includes bare copper conductors, shielding with aluminum tape and TC (Tinned Copper) braid, and a PVC jacket.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eGaalflex VFD 1405 600V Cable specifications\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eBare Copper Shielded Al Tape TC Braid PVC Tray Cable\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eInstrumentation cable standards\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eTray cable applications and usage\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eVFD cable for motor drives\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eShielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThis cable is shielded, which means it provides protection against electromagnetic interference (EMI) and radio-frequency interference (RFI). This shielding ensures stable and reliable signal transmission, critical for VFD systems.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eBare Copper Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe use of bare copper conductors ensures excellent electrical conductivity, reducing energy losses and allowing for efficient power transmission.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eAluminum Tape and TC Braid Shielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe combination of aluminum tape and tinned copper (TC) braid shielding provides enhanced protection against EMI and RFI, making it ideal for VFD applications where signal integrity is crucial.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003ePVC Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe PVC (Polyvinyl Chloride) jacket offers durability and resistance to environmental factors, making the cable suitable for both indoor and outdoor tray installations.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e600V Rating:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eWith a 600V rating, this cable can handle the voltage requirements of many VFD systems commonly used in industrial settings.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eNational Electrical Code (NEC):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor general electrical installation guidelines.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUL (Underwriters Laboratories):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eEnsuring safety and performance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIEEE Standards:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor specific applications like VFDs.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eLocal Electrical Codes:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eLocal regulations for compliance.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eConductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eflexible red copper conductor Cl. 5, acc. to IEC 60228, DIN VDE 0295 and UL standard 83\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eInsulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003efrom 18 AWG up to 16 AWG: GAALTHERM 520 from 14 AWG and over: GAALTHERM 591\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eCores color:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+3g..: 3 black conductors numbered + 3 green-yellow conductors divided in 3 inertstices 3x..+1g.. \/ 4g..+(2x..) or 4g..+(2x..+2x..): black cores with consecutive numbers acc. to EN 50334 + green\/yellow\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eStranding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+1g..: cores twisted together + fillers 3x..+3g..: phase units laid up with earth-conductors in interstices 4g..+(2x..) or 4g..+(2x..+2x..): control cores twisted in pair(s) and screened, supply cores and control screened pair(s) twisted together\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIndividual screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e4g..+(2x..) or 4g..+(2x..+2x..): aluminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOverall screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ealuminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOuter Sheath:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eblack (similar RAL 9005), GAALTHERM 520\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUV resistant\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eoutdoor use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003einstallation in hazardous areas\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 2277 WTTC or Flexible Motor Supply\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 1277 (Oil-resistant according to UL OIL RES I and Water-resistant, UL 90°C Dry or 90°C Wet )\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUL only for TC-ER use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request c(UL) type CIC\/TC FT4, AWM I\/II A\/B FT4\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request DIRECT BURIAL\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to to NFPA 79 2007 and NEC 336.10(7) Class 1, Div. 2 Art. 336, 392, 501\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for application acc. to EN 55011, DIN VDE 0875 and EN 61800-3\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for chain application, see technical data*\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eRoHS and CE approval\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• No. of cores x cross section n x AWG\/MCM:\u003c\/strong\u003e 3 x 4\/0 + 3 G 6\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Outer Ø inches\/mm ±10%:\u003c\/strong\u003e\u003cspan\u003e 1,788 - 44,7\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Nominal voltage:\u003c\/strong\u003e\u003cspan\u003e UL 1277 TC-ER-600 V, UL 2277 WTTC \/ Flexible Motor Supply-1000 V, IEC: Uo\/U 600\/1000 V\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Temperature range UL:\u003cspan\u003e  \u003c\/span\u003e\u003c\/strong\u003eup to 90°C Fixed laying: - 40 oC up to + 105 oC Flexible installation: - 5 oC up to + 105 oC\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Min. bending radius:\u003c\/strong\u003e\u003cspan\u003e Fixed laying: 6 x d Flexible application: 20 x d\u003cbr\u003e\u003cstrong\u003e• Copper weight Lbs\/Mf:\u003c\/strong\u003e 2835,2\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Cable weight approx. Lbs\/Mft:\u003c\/strong\u003e\u003cspan\u003e 3198,7\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e\u003cspan\u003e 33290F70037A4C\u003c\/span\u003e\u003c\/p\u003e","brand":"Elettrotek Kabel","offers":[{"title":"Default Title","offer_id":44265899262106,"sku":"33290F70037A4C","price":67.46,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/308_afc6378f-1d93-46d6-a7d5-4f82c4185849.png?v=1762987898"},{"product_id":"250-3c-4-3c-bare-copper-shielded-al-tape-tc-braid-pvc-gaalflex-tray-vfd-1405-600v-cable","title":"250\/3C+4\/3C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/F2143-American-Industrial-Mining-Cables_removed_7.pdf?v=1703677301\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e250\/3C+4\/3C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 250\/3C+4\/3C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Gaalflex Bare Copper Shielded Al Tape TC Braid PVC Tray VFD 1405 600V Cable is a specialized cable designed for use in various industrial applications. It features a construction that includes bare copper conductors, shielding with aluminum tape and TC (Tinned Copper) braid, and a PVC jacket.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eGaalflex VFD 1405 600V Cable specifications\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eBare Copper Shielded Al Tape TC Braid PVC Tray Cable\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eInstrumentation cable standards\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eTray cable applications and usage\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eVFD cable for motor drives\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eShielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThis cable is shielded, which means it provides protection against electromagnetic interference (EMI) and radio-frequency interference (RFI). This shielding ensures stable and reliable signal transmission, critical for VFD systems.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eBare Copper Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe use of bare copper conductors ensures excellent electrical conductivity, reducing energy losses and allowing for efficient power transmission.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eAluminum Tape and TC Braid Shielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe combination of aluminum tape and tinned copper (TC) braid shielding provides enhanced protection against EMI and RFI, making it ideal for VFD applications where signal integrity is crucial.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003ePVC Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe PVC (Polyvinyl Chloride) jacket offers durability and resistance to environmental factors, making the cable suitable for both indoor and outdoor tray installations.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e600V Rating:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eWith a 600V rating, this cable can handle the voltage requirements of many VFD systems commonly used in industrial settings.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eNational Electrical Code (NEC):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor general electrical installation guidelines.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUL (Underwriters Laboratories):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eEnsuring safety and performance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIEEE Standards:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor specific applications like VFDs.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eLocal Electrical Codes:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eLocal regulations for compliance.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eConductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eflexible red copper conductor Cl. 5, acc. to IEC 60228, DIN VDE 0295 and UL standard 83\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eInsulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003efrom 18 AWG up to 16 AWG: GAALTHERM 520 from 14 AWG and over: GAALTHERM 591\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eCores color:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+3g..: 3 black conductors numbered + 3 green-yellow conductors divided in 3 inertstices 3x..+1g.. \/ 4g..+(2x..) or 4g..+(2x..+2x..): black cores with consecutive numbers acc. to EN 50334 + green\/yellow\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eStranding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+1g..: cores twisted together + fillers 3x..+3g..: phase units laid up with earth-conductors in interstices 4g..+(2x..) or 4g..+(2x..+2x..): control cores twisted in pair(s) and screened, supply cores and control screened pair(s) twisted together\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIndividual screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e4g..+(2x..) or 4g..+(2x..+2x..): aluminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOverall screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ealuminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOuter Sheath:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eblack (similar RAL 9005), GAALTHERM 520\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUV resistant\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eoutdoor use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003einstallation in hazardous areas\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 2277 WTTC or Flexible Motor Supply\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 1277 (Oil-resistant according to UL OIL RES I and Water-resistant, UL 90°C Dry or 90°C Wet )\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUL only for TC-ER use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request c(UL) type CIC\/TC FT4, AWM I\/II A\/B FT4\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request DIRECT BURIAL\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to to NFPA 79 2007 and NEC 336.10(7) Class 1, Div. 2 Art. 336, 392, 501\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for application acc. to EN 55011, DIN VDE 0875 and EN 61800-3\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for chain application, see technical data*\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eRoHS and CE approval\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• No. of cores x cross section n x AWG\/MCM:\u003c\/strong\u003e 3 x 250 + 3 G 4\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Outer Ø inches\/mm ±10%:\u003c\/strong\u003e\u003cspan\u003e 1,928 - 48,2\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Nominal voltage:\u003c\/strong\u003e\u003cspan\u003e UL 1277 TC-ER-600 V, UL 2277 WTTC \/ Flexible Motor Supply-1000 V, IEC: Uo\/U 600\/1000 V\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Temperature range UL:\u003cspan\u003e  \u003c\/span\u003e\u003c\/strong\u003eup to 90°C Fixed laying: - 40 oC up to + 105 oC Flexible installation: - 5 oC up to + 105 oC\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Min. bending radius:\u003c\/strong\u003e\u003cspan\u003e Fixed laying: 6 x d Flexible application: 20 x d\u003cbr\u003e\u003cstrong\u003e• Copper weight Lbs\/Mf:\u003c\/strong\u003e 3608,6\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Cable weight approx. Lbs\/Mft:\u003c\/strong\u003e\u003cspan\u003e 3972,9\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e\u003cspan\u003e 33290F70037A5C\u003c\/span\u003e\u003c\/p\u003e","brand":"Elettrotek Kabel","offers":[{"title":"Default Title","offer_id":44265900310682,"sku":"33290F70037A5C","price":85.06,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/308_dc468a1a-8e6c-47bc-b721-8ffe4d174d06.png?v=1762987899"},{"product_id":"300-3c-2-3c-bare-copper-shielded-al-tape-tc-braid-pvc-gaalflex-tray-vfd-1405-600v-cable","title":"300\/3C+2\/3C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/F2143-American-Industrial-Mining-Cables_removed_7.pdf?v=1703677301\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e300\/3C+2\/3C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 300\/3C+2\/3C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Gaalflex Bare Copper Shielded Al Tape TC Braid PVC Tray VFD 1405 600V Cable is a specialized cable designed for use in various industrial applications. It features a construction that includes bare copper conductors, shielding with aluminum tape and TC (Tinned Copper) braid, and a PVC jacket.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eGaalflex VFD 1405 600V Cable specifications\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eBare Copper Shielded Al Tape TC Braid PVC Tray Cable\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eInstrumentation cable standards\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eTray cable applications and usage\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eVFD cable for motor drives\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eShielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThis cable is shielded, which means it provides protection against electromagnetic interference (EMI) and radio-frequency interference (RFI). This shielding ensures stable and reliable signal transmission, critical for VFD systems.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eBare Copper Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe use of bare copper conductors ensures excellent electrical conductivity, reducing energy losses and allowing for efficient power transmission.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eAluminum Tape and TC Braid Shielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe combination of aluminum tape and tinned copper (TC) braid shielding provides enhanced protection against EMI and RFI, making it ideal for VFD applications where signal integrity is crucial.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003ePVC Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe PVC (Polyvinyl Chloride) jacket offers durability and resistance to environmental factors, making the cable suitable for both indoor and outdoor tray installations.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e600V Rating:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eWith a 600V rating, this cable can handle the voltage requirements of many VFD systems commonly used in industrial settings.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eNational Electrical Code (NEC):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor general electrical installation guidelines.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUL (Underwriters Laboratories):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eEnsuring safety and performance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIEEE Standards:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor specific applications like VFDs.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eLocal Electrical Codes:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eLocal regulations for compliance.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eConductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eflexible red copper conductor Cl. 5, acc. to IEC 60228, DIN VDE 0295 and UL standard 83\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eInsulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003efrom 18 AWG up to 16 AWG: GAALTHERM 520 from 14 AWG and over: GAALTHERM 591\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eCores color:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+3g..: 3 black conductors numbered + 3 green-yellow conductors divided in 3 inertstices 3x..+1g.. \/ 4g..+(2x..) or 4g..+(2x..+2x..): black cores with consecutive numbers acc. to EN 50334 + green\/yellow\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eStranding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+1g..: cores twisted together + fillers 3x..+3g..: phase units laid up with earth-conductors in interstices 4g..+(2x..) or 4g..+(2x..+2x..): control cores twisted in pair(s) and screened, supply cores and control screened pair(s) twisted together\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIndividual screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e4g..+(2x..) or 4g..+(2x..+2x..): aluminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOverall screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ealuminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOuter Sheath:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eblack (similar RAL 9005), GAALTHERM 520\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUV resistant\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eoutdoor use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003einstallation in hazardous areas\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 2277 WTTC or Flexible Motor Supply\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 1277 (Oil-resistant according to UL OIL RES I and Water-resistant, UL 90°C Dry or 90°C Wet )\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUL only for TC-ER use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request c(UL) type CIC\/TC FT4, AWM I\/II A\/B FT4\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request DIRECT BURIAL\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to to NFPA 79 2007 and NEC 336.10(7) Class 1, Div. 2 Art. 336, 392, 501\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for application acc. to EN 55011, DIN VDE 0875 and EN 61800-3\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for chain application, see technical data*\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eRoHS and CE approval\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• No. of cores x cross section n x AWG\/MCM:\u003c\/strong\u003e 3 x 350 + 3 G 2\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Outer Ø inches\/mm ±10%:\u003c\/strong\u003e\u003cspan\u003e 2,084 - 52,1\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Nominal voltage:\u003c\/strong\u003e\u003cspan\u003e UL 1277 TC-ER-600 V, UL 2277 WTTC \/ Flexible Motor Supply-1000 V, IEC: Uo\/U 600\/1000 V\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Temperature range UL:\u003cspan\u003e  \u003c\/span\u003e\u003c\/strong\u003eup to 90°C Fixed laying: - 40 oC up to + 105 oC Flexible installation: - 5 oC up to + 105 oC\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Min. bending radius:\u003c\/strong\u003e\u003cspan\u003e Fixed laying: 6 x d Flexible application: 20 x d\u003cbr\u003e\u003cstrong\u003e• Copper weight Lbs\/Mf:\u003c\/strong\u003e 4497,7 \u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Cable weight approx. Lbs\/Mft:\u003c\/strong\u003e\u003cspan\u003e 4831,7\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e\u003cspan\u003e 33290F70037A7C\u003c\/span\u003e\u003c\/p\u003e","brand":"Elettrotek Kabel","offers":[{"title":"Default Title","offer_id":44265927213210,"sku":"33290F70037A7C","price":100.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/308_5cb24251-0588-4f01-b19a-ee958473dadc.png?v=1762987910"},{"product_id":"500-3c-6-3c-bare-copper-shielded-al-tape-tc-braid-pvc-gaalflex-tray-vfd-1405-600v-cable","title":"500\/3C+6\/3C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/F2143-American-Industrial-Mining-Cables_removed_7.pdf?v=1703677301\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e500\/3C+6\/3C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 500\/3C+6\/3C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Gaalflex Bare Copper Shielded Al Tape TC Braid PVC Tray VFD 1405 600V Cable is a specialized cable designed for use in various industrial applications. It features a construction that includes bare copper conductors, shielding with aluminum tape and TC (Tinned Copper) braid, and a PVC jacket.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eGaalflex VFD 1405 600V Cable specifications\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eBare Copper Shielded Al Tape TC Braid PVC Tray Cable\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eInstrumentation cable standards\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eTray cable applications and usage\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eVFD cable for motor drives\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eShielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThis cable is shielded, which means it provides protection against electromagnetic interference (EMI) and radio-frequency interference (RFI). This shielding ensures stable and reliable signal transmission, critical for VFD systems.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eBare Copper Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe use of bare copper conductors ensures excellent electrical conductivity, reducing energy losses and allowing for efficient power transmission.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eAluminum Tape and TC Braid Shielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe combination of aluminum tape and tinned copper (TC) braid shielding provides enhanced protection against EMI and RFI, making it ideal for VFD applications where signal integrity is crucial.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003ePVC Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe PVC (Polyvinyl Chloride) jacket offers durability and resistance to environmental factors, making the cable suitable for both indoor and outdoor tray installations.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e600V Rating:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eWith a 600V rating, this cable can handle the voltage requirements of many VFD systems commonly used in industrial settings.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eNational Electrical Code (NEC):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor general electrical installation guidelines.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUL (Underwriters Laboratories):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eEnsuring safety and performance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIEEE Standards:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor specific applications like VFDs.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eLocal Electrical Codes:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eLocal regulations for compliance.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eConductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eflexible red copper conductor Cl. 5, acc. to IEC 60228, DIN VDE 0295 and UL standard 83\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eInsulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003efrom 18 AWG up to 16 AWG: GAALTHERM 520 from 14 AWG and over: GAALTHERM 591\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eCores color:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+3g..: 3 black conductors numbered + 3 green-yellow conductors divided in 3 inertstices 3x..+1g.. \/ 4g..+(2x..) or 4g..+(2x..+2x..): black cores with consecutive numbers acc. to EN 50334 + green\/yellow\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eStranding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+1g..: cores twisted together + fillers 3x..+3g..: phase units laid up with earth-conductors in interstices 4g..+(2x..) or 4g..+(2x..+2x..): control cores twisted in pair(s) and screened, supply cores and control screened pair(s) twisted together\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIndividual screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e4g..+(2x..) or 4g..+(2x..+2x..): aluminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOverall screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ealuminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOuter Sheath:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eblack (similar RAL 9005), GAALTHERM 520\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUV resistant\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eoutdoor use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003einstallation in hazardous areas\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 2277 WTTC or Flexible Motor Supply\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 1277 (Oil-resistant according to UL OIL RES I and Water-resistant, UL 90°C Dry or 90°C Wet )\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUL only for TC-ER use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request c(UL) type CIC\/TC FT4, AWM I\/II A\/B FT4\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request DIRECT BURIAL\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to to NFPA 79 2007 and NEC 336.10(7) Class 1, Div. 2 Art. 336, 392, 501\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for application acc. to EN 55011, DIN VDE 0875 and EN 61800-3\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for chain application, see technical data*\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eRoHS and CE approval\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• No. of cores x cross section n x AWG\/MCM:\u003c\/strong\u003e 3 x 500 + 3 G 6\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Outer Ø inches\/mm ±10%:\u003c\/strong\u003e\u003cspan\u003e 2,365 - 60,1\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Nominal voltage:\u003c\/strong\u003e\u003cspan\u003e UL 1277 TC-ER-600 V, UL 2277 WTTC \/ Flexible Motor Supply-1000 V, IEC: Uo\/U 600\/1000 V\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Temperature range UL:\u003cspan\u003e  \u003c\/span\u003e\u003c\/strong\u003eup to 90°C Fixed laying: - 40 oC up to + 105 oC Flexible installation: - 5 oC up to + 105 oC\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Min. bending radius:\u003c\/strong\u003e\u003cspan\u003e Fixed laying: 6 x d Flexible application: 20 x d\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Cable weight approx. Lbs\/Mft:\u003c\/strong\u003e\u003cspan\u003e 6392\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e\u003cspan\u003e 33290F70037AAC\u003c\/span\u003e\u003c\/p\u003e","brand":"Elettrotek Kabel","offers":[{"title":"Default Title","offer_id":44265936519322,"sku":"33290F70037AAC","price":136.57,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/308_021bdca8-3d95-4c6c-9a1f-8f7cd2744a9d.png?v=1762987913"},{"product_id":"14-4c-18-2c-bare-copper-shielded-al-tape-tc-braid-pvc-gaalflex-tray-vfd-1405-600v-cable","title":"14\/4C+18\/2C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/F2143-American-Industrial-Mining-Cables_removed_7.pdf?v=1703677301\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e14\/4C+18\/2C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 14\/4C+18\/2C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Gaalflex Bare Copper Shielded Al Tape TC Braid PVC Tray VFD 1405 600V Cable is a specialized cable designed for use in various industrial applications. It features a construction that includes bare copper conductors, shielding with aluminum tape and TC (Tinned Copper) braid, and a PVC jacket.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eGaalflex VFD 1405 600V Cable specifications\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eBare Copper Shielded Al Tape TC Braid PVC Tray Cable\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eInstrumentation cable standards\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eTray cable applications and usage\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eVFD cable for motor drives\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eShielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThis cable is shielded, which means it provides protection against electromagnetic interference (EMI) and radio-frequency interference (RFI). This shielding ensures stable and reliable signal transmission, critical for VFD systems.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eBare Copper Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe use of bare copper conductors ensures excellent electrical conductivity, reducing energy losses and allowing for efficient power transmission.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eAluminum Tape and TC Braid Shielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe combination of aluminum tape and tinned copper (TC) braid shielding provides enhanced protection against EMI and RFI, making it ideal for VFD applications where signal integrity is crucial.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003ePVC Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe PVC (Polyvinyl Chloride) jacket offers durability and resistance to environmental factors, making the cable suitable for both indoor and outdoor tray installations.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e600V Rating:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eWith a 600V rating, this cable can handle the voltage requirements of many VFD systems commonly used in industrial settings.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eNational Electrical Code (NEC):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor general electrical installation guidelines.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUL (Underwriters Laboratories):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eEnsuring safety and performance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIEEE Standards:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor specific applications like VFDs.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eLocal Electrical Codes:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eLocal regulations for compliance.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eConductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eflexible red copper conductor Cl. 5, acc. to IEC 60228, DIN VDE 0295 and UL standard 83\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eInsulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003efrom 18 AWG up to 16 AWG: GAALTHERM 520 from 14 AWG and over: GAALTHERM 591\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eCores color:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+3g..: 3 black conductors numbered + 3 green-yellow conductors divided in 3 inertstices 3x..+1g.. \/ 4g..+(2x..) or 4g..+(2x..+2x..): black cores with consecutive numbers acc. to EN 50334 + green\/yellow\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eStranding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+1g..: cores twisted together + fillers 3x..+3g..: phase units laid up with earth-conductors in interstices 4g..+(2x..) or 4g..+(2x..+2x..): control cores twisted in pair(s) and screened, supply cores and control screened pair(s) twisted together\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIndividual screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e4g..+(2x..) or 4g..+(2x..+2x..): aluminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOverall screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ealuminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOuter Sheath:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eblack (similar RAL 9005), GAALTHERM 520\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUV resistant\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eoutdoor use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003einstallation in hazardous areas\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 2277 WTTC or Flexible Motor Supply\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 1277 (Oil-resistant according to UL OIL RES I and Water-resistant, UL 90°C Dry or 90°C Wet )\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUL only for TC-ER use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request c(UL) type CIC\/TC FT4, AWM I\/II A\/B FT4\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request DIRECT BURIAL\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to to NFPA 79 2007 and NEC 336.10(7) Class 1, Div. 2 Art. 336, 392, 501\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for application acc. to EN 55011, DIN VDE 0875 and EN 61800-3\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for chain application, see technical data*\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eRoHS and CE approval\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• No. of cores x cross section n x AWG\/MCM:\u003c\/strong\u003e 4 G 14 + (2 x 18)C\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Outer Ø inches\/mm ±10%:\u003c\/strong\u003e\u003cspan\u003e 0,608 - 15,2\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Nominal voltage:\u003c\/strong\u003e\u003cspan\u003e UL 1277 TC-ER-600 V, UL 2277 WTTC \/ Flexible Motor Supply-1000 V, IEC: Uo\/U 600\/1000 V\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Temperature range UL:\u003cspan\u003e  \u003c\/span\u003e\u003c\/strong\u003eup to 90°C Fixed laying: - 40 oC up to + 105 oC Flexible installation: - 5 oC up to + 105 oC\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Min. bending radius:\u003c\/strong\u003e\u003cspan\u003e Fixed laying: 6 x d Flexible application: 20 x d\u003cbr\u003e\u003cstrong\u003e• Copper weight Lbs\/Mft: \u003c\/strong\u003e135,7\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Cable weight approx. Lbs\/Mft:\u003c\/strong\u003e\u003cspan\u003e 229,2\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e\u003cspan\u003e 33290F7004BA14\u003c\/span\u003e\u003c\/p\u003e","brand":"Elettrotek Kabel","offers":[{"title":"Default Title","offer_id":44265938485402,"sku":"33290F7004BA14","price":4.25,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/308_204334fa-3451-4dcf-9204-74d96aa21569.png?v=1762987914"},{"product_id":"12-4c-18-2c-bare-copper-shielded-al-tape-tc-braid-pvc-gaalflex-tray-vfd-1405-600v-cable","title":"12\/4C+18\/2C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/F2143-American-Industrial-Mining-Cables_removed_7.pdf?v=1703677301\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e12\/4C+18\/2C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 12\/4C+18\/2C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Gaalflex Bare Copper Shielded Al Tape TC Braid PVC Tray VFD 1405 600V Cable is a specialized cable designed for use in various industrial applications. It features a construction that includes bare copper conductors, shielding with aluminum tape and TC (Tinned Copper) braid, and a PVC jacket.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eGaalflex VFD 1405 600V Cable specifications\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eBare Copper Shielded Al Tape TC Braid PVC Tray Cable\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eInstrumentation cable standards\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eTray cable applications and usage\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eVFD cable for motor drives\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eShielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThis cable is shielded, which means it provides protection against electromagnetic interference (EMI) and radio-frequency interference (RFI). This shielding ensures stable and reliable signal transmission, critical for VFD systems.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eBare Copper Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe use of bare copper conductors ensures excellent electrical conductivity, reducing energy losses and allowing for efficient power transmission.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eAluminum Tape and TC Braid Shielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe combination of aluminum tape and tinned copper (TC) braid shielding provides enhanced protection against EMI and RFI, making it ideal for VFD applications where signal integrity is crucial.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003ePVC Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe PVC (Polyvinyl Chloride) jacket offers durability and resistance to environmental factors, making the cable suitable for both indoor and outdoor tray installations.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e600V Rating:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eWith a 600V rating, this cable can handle the voltage requirements of many VFD systems commonly used in industrial settings.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eNational Electrical Code (NEC):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor general electrical installation guidelines.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUL (Underwriters Laboratories):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eEnsuring safety and performance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIEEE Standards:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor specific applications like VFDs.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eLocal Electrical Codes:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eLocal regulations for compliance.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eConductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eflexible red copper conductor Cl. 5, acc. to IEC 60228, DIN VDE 0295 and UL standard 83\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eInsulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003efrom 18 AWG up to 16 AWG: GAALTHERM 520 from 14 AWG and over: GAALTHERM 591\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eCores color:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+3g..: 3 black conductors numbered + 3 green-yellow conductors divided in 3 inertstices 3x..+1g.. \/ 4g..+(2x..) or 4g..+(2x..+2x..): black cores with consecutive numbers acc. to EN 50334 + green\/yellow\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eStranding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+1g..: cores twisted together + fillers 3x..+3g..: phase units laid up with earth-conductors in interstices 4g..+(2x..) or 4g..+(2x..+2x..): control cores twisted in pair(s) and screened, supply cores and control screened pair(s) twisted together\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIndividual screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e4g..+(2x..) or 4g..+(2x..+2x..): aluminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOverall screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ealuminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOuter Sheath:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eblack (similar RAL 9005), GAALTHERM 520\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUV resistant\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eoutdoor use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003einstallation in hazardous areas\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 2277 WTTC or Flexible Motor Supply\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 1277 (Oil-resistant according to UL OIL RES I and Water-resistant, UL 90°C Dry or 90°C Wet )\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUL only for TC-ER use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request c(UL) type CIC\/TC FT4, AWM I\/II A\/B FT4\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request DIRECT BURIAL\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to to NFPA 79 2007 and NEC 336.10(7) Class 1, Div. 2 Art. 336, 392, 501\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for application acc. to EN 55011, DIN VDE 0875 and EN 61800-3\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for chain application, see technical data*\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eRoHS and CE approval\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• No. of cores x cross section n x AWG\/MCM:\u003c\/strong\u003e 4 G 12 + (2 x 18)C\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Outer Ø inches\/mm ±10%:\u003c\/strong\u003e\u003cspan\u003e 0,66 - 16,5\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Nominal voltage:\u003c\/strong\u003e\u003cspan\u003e UL 1277 TC-ER-600 V, UL 2277 WTTC \/ Flexible Motor Supply-1000 V, IEC: Uo\/U 600\/1000 V\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Temperature range UL:\u003cspan\u003e  \u003c\/span\u003e\u003c\/strong\u003eup to 90°C Fixed laying: - 40 oC up to + 105 oC Flexible installation: - 5 oC up to + 105 oC\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Min. bending radius:\u003c\/strong\u003e\u003cspan\u003e Fixed laying: 6 x d Flexible application: 20 x d\u003cbr\u003e\u003cstrong\u003e• Copper weight Lbs\/Mft:\u003c\/strong\u003e 179,4\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Cable weight approx. Lbs\/Mft:\u003c\/strong\u003e\u003cspan\u003e 284,2\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e\u003cspan\u003e 33290F7004BA12\u003c\/span\u003e\u003c\/p\u003e","brand":"Elettrotek Kabel","offers":[{"title":"Default Title","offer_id":44265954115738,"sku":"33290F7004BA12","price":5.47,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/308_7b6a0409-d7f6-4314-b5e8-365881c177ad.png?v=1762987917"},{"product_id":"14-4c-16-2c-bare-copper-shielded-al-tape-tc-braid-pvc-gaalflex-tray-vfd-1405-600v-cable","title":"14\/4C+16\/2C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/F2143-American-Industrial-Mining-Cables_removed_7.pdf?v=1703677301\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e14\/4C+16\/2C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 14\/4C+16\/2C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Gaalflex Bare Copper Shielded Al Tape TC Braid PVC Tray VFD 1405 600V Cable is a specialized cable designed for use in various industrial applications. It features a construction that includes bare copper conductors, shielding with aluminum tape and TC (Tinned Copper) braid, and a PVC jacket.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eGaalflex VFD 1405 600V Cable specifications\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eBare Copper Shielded Al Tape TC Braid PVC Tray Cable\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eInstrumentation cable standards\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eTray cable applications and usage\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eVFD cable for motor drives\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eShielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThis cable is shielded, which means it provides protection against electromagnetic interference (EMI) and radio-frequency interference (RFI). This shielding ensures stable and reliable signal transmission, critical for VFD systems.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eBare Copper Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe use of bare copper conductors ensures excellent electrical conductivity, reducing energy losses and allowing for efficient power transmission.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eAluminum Tape and TC Braid Shielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe combination of aluminum tape and tinned copper (TC) braid shielding provides enhanced protection against EMI and RFI, making it ideal for VFD applications where signal integrity is crucial.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003ePVC Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe PVC (Polyvinyl Chloride) jacket offers durability and resistance to environmental factors, making the cable suitable for both indoor and outdoor tray installations.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e600V Rating:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eWith a 600V rating, this cable can handle the voltage requirements of many VFD systems commonly used in industrial settings.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eNational Electrical Code (NEC):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor general electrical installation guidelines.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUL (Underwriters Laboratories):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eEnsuring safety and performance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIEEE Standards:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor specific applications like VFDs.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eLocal Electrical Codes:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eLocal regulations for compliance.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eConductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eflexible red copper conductor Cl. 5, acc. to IEC 60228, DIN VDE 0295 and UL standard 83\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eInsulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003efrom 18 AWG up to 16 AWG: GAALTHERM 520 from 14 AWG and over: GAALTHERM 591\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eCores color:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+3g..: 3 black conductors numbered + 3 green-yellow conductors divided in 3 inertstices 3x..+1g.. \/ 4g..+(2x..) or 4g..+(2x..+2x..): black cores with consecutive numbers acc. to EN 50334 + green\/yellow\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eStranding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+1g..: cores twisted together + fillers 3x..+3g..: phase units laid up with earth-conductors in interstices 4g..+(2x..) or 4g..+(2x..+2x..): control cores twisted in pair(s) and screened, supply cores and control screened pair(s) twisted together\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIndividual screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e4g..+(2x..) or 4g..+(2x..+2x..): aluminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOverall screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ealuminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOuter Sheath:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eblack (similar RAL 9005), GAALTHERM 520\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUV resistant\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eoutdoor use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003einstallation in hazardous areas\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 2277 WTTC or Flexible Motor Supply\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 1277 (Oil-resistant according to UL OIL RES I and Water-resistant, UL 90°C Dry or 90°C Wet )\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUL only for TC-ER use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request c(UL) type CIC\/TC FT4, AWM I\/II A\/B FT4\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request DIRECT BURIAL\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to to NFPA 79 2007 and NEC 336.10(7) Class 1, Div. 2 Art. 336, 392, 501\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for application acc. to EN 55011, DIN VDE 0875 and EN 61800-3\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for chain application, see technical data*\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eRoHS and CE approval\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• No. of cores x cross section n x AWG\/MCM:\u003c\/strong\u003e 4 G 14 + (2 x 16)C\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Outer Ø inches\/mm ±10%:\u003c\/strong\u003e\u003cspan\u003e 0,63 - 15,7\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Nominal voltage:\u003c\/strong\u003e\u003cspan\u003e UL 1277 TC-ER-600 V, UL 2277 WTTC \/ Flexible Motor Supply-1000 V, IEC: Uo\/U 600\/1000 V\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Temperature range UL:\u003cspan\u003e  \u003c\/span\u003e\u003c\/strong\u003eup to 90°C Fixed laying: - 40 oC up to + 105 oC Flexible installation: - 5 oC up to + 105 oC\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Min. bending radius:\u003c\/strong\u003e\u003cspan\u003e Fixed laying: 6 x d Flexible application: 20 x d\u003cbr\u003e\u003cstrong\u003e• Copper weight Lbs\/Mft:\u003c\/strong\u003e 149,9\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Cable weight approx. Lbs\/Mft:\u003c\/strong\u003e\u003cspan\u003e 246\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e\u003cspan\u003e 33291F7004BA14\u003c\/span\u003e\u003c\/p\u003e","brand":"Elettrotek Kabel","offers":[{"title":"Default Title","offer_id":44265956802714,"sku":"33291F7004BA14","price":4.67,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/308_8ca8a35b-b15f-4a36-abd6-7230fac66fce.png?v=1762987918"},{"product_id":"12-4c-16-2c-bare-copper-shielded-al-tape-tc-braid-pvc-gaalflex-tray-vfd-1405-600v-cable","title":"12\/4C+16\/2C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/F2143-American-Industrial-Mining-Cables_removed_7.pdf?v=1703677301\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e12\/4C+16\/2C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 12\/4C+16\/2C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Gaalflex Bare Copper Shielded Al Tape TC Braid PVC Tray VFD 1405 600V Cable is a specialized cable designed for use in various industrial applications. It features a construction that includes bare copper conductors, shielding with aluminum tape and TC (Tinned Copper) braid, and a PVC jacket.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eGaalflex VFD 1405 600V Cable specifications\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eBare Copper Shielded Al Tape TC Braid PVC Tray Cable\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eInstrumentation cable standards\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eTray cable applications and usage\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eVFD cable for motor drives\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eShielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThis cable is shielded, which means it provides protection against electromagnetic interference (EMI) and radio-frequency interference (RFI). This shielding ensures stable and reliable signal transmission, critical for VFD systems.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eBare Copper Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe use of bare copper conductors ensures excellent electrical conductivity, reducing energy losses and allowing for efficient power transmission.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eAluminum Tape and TC Braid Shielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe combination of aluminum tape and tinned copper (TC) braid shielding provides enhanced protection against EMI and RFI, making it ideal for VFD applications where signal integrity is crucial.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003ePVC Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe PVC (Polyvinyl Chloride) jacket offers durability and resistance to environmental factors, making the cable suitable for both indoor and outdoor tray installations.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e600V Rating:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eWith a 600V rating, this cable can handle the voltage requirements of many VFD systems commonly used in industrial settings.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eNational Electrical Code (NEC):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor general electrical installation guidelines.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUL (Underwriters Laboratories):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eEnsuring safety and performance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIEEE Standards:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor specific applications like VFDs.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eLocal Electrical Codes:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eLocal regulations for compliance.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eConductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eflexible red copper conductor Cl. 5, acc. to IEC 60228, DIN VDE 0295 and UL standard 83\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eInsulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003efrom 18 AWG up to 16 AWG: GAALTHERM 520 from 14 AWG and over: GAALTHERM 591\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eCores color:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+3g..: 3 black conductors numbered + 3 green-yellow conductors divided in 3 inertstices 3x..+1g.. \/ 4g..+(2x..) or 4g..+(2x..+2x..): black cores with consecutive numbers acc. to EN 50334 + green\/yellow\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eStranding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+1g..: cores twisted together + fillers 3x..+3g..: phase units laid up with earth-conductors in interstices 4g..+(2x..) or 4g..+(2x..+2x..): control cores twisted in pair(s) and screened, supply cores and control screened pair(s) twisted together\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIndividual screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e4g..+(2x..) or 4g..+(2x..+2x..): aluminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOverall screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ealuminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOuter Sheath:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eblack (similar RAL 9005), GAALTHERM 520\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUV resistant\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eoutdoor use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003einstallation in hazardous areas\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 2277 WTTC or Flexible Motor Supply\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 1277 (Oil-resistant according to UL OIL RES I and Water-resistant, UL 90°C Dry or 90°C Wet )\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUL only for TC-ER use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request c(UL) type CIC\/TC FT4, AWM I\/II A\/B FT4\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request DIRECT BURIAL\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to to NFPA 79 2007 and NEC 336.10(7) Class 1, Div. 2 Art. 336, 392, 501\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for application acc. to EN 55011, DIN VDE 0875 and EN 61800-3\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for chain application, see technical data*\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eRoHS and CE approval\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• No. of cores x cross section n x AWG\/MCM:\u003c\/strong\u003e 4 G 12 + (2 x 16)C\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Outer Ø inches\/mm ±10%:\u003c\/strong\u003e\u003cspan\u003e 0,68 - 17\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Nominal voltage:\u003c\/strong\u003e\u003cspan\u003e UL 1277 TC-ER-600 V, UL 2277 WTTC \/ Flexible Motor Supply-1000 V, IEC: Uo\/U 600\/1000 V\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Temperature range UL:\u003cspan\u003e  \u003c\/span\u003e\u003c\/strong\u003eup to 90°C Fixed laying: - 40 oC up to + 105 oC Flexible installation: - 5 oC up to + 105 oC\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Min. bending radius:\u003c\/strong\u003e\u003cspan\u003e Fixed laying: 6 x d Flexible application: 20 x d\u003cbr\u003e\u003cstrong\u003e• Copper weight Lbs\/Mft:\u003c\/strong\u003e 193,5\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Cable weight approx. Lbs\/Mft:\u003c\/strong\u003e\u003cspan\u003e 302,4\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e\u003cspan\u003e 33291F7004BA12\u003c\/span\u003e\u003c\/p\u003e","brand":"Elettrotek Kabel","offers":[{"title":"Default Title","offer_id":44265964011674,"sku":"33291F7004BA12","price":5.77,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/308_c7189272-d1fc-45dd-9968-dc7820106fa7.png?v=1762987920"},{"product_id":"10-4c-16-2c-bare-copper-shielded-al-tape-tc-braid-pvc-gaalflex-tray-vfd-1405-600v-cable","title":"10\/4C+16\/2C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/F2143-American-Industrial-Mining-Cables_removed_7.pdf?v=1703677301\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e10\/4C+16\/2C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 10\/4C+16\/2C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Gaalflex Bare Copper Shielded Al Tape TC Braid PVC Tray VFD 1405 600V Cable is a specialized cable designed for use in various industrial applications. It features a construction that includes bare copper conductors, shielding with aluminum tape and TC (Tinned Copper) braid, and a PVC jacket.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eGaalflex VFD 1405 600V Cable specifications\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eBare Copper Shielded Al Tape TC Braid PVC Tray Cable\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eInstrumentation cable standards\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eTray cable applications and usage\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eVFD cable for motor drives\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eShielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThis cable is shielded, which means it provides protection against electromagnetic interference (EMI) and radio-frequency interference (RFI). This shielding ensures stable and reliable signal transmission, critical for VFD systems.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eBare Copper Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe use of bare copper conductors ensures excellent electrical conductivity, reducing energy losses and allowing for efficient power transmission.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eAluminum Tape and TC Braid Shielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe combination of aluminum tape and tinned copper (TC) braid shielding provides enhanced protection against EMI and RFI, making it ideal for VFD applications where signal integrity is crucial.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003ePVC Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe PVC (Polyvinyl Chloride) jacket offers durability and resistance to environmental factors, making the cable suitable for both indoor and outdoor tray installations.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e600V Rating:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eWith a 600V rating, this cable can handle the voltage requirements of many VFD systems commonly used in industrial settings.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eNational Electrical Code (NEC):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor general electrical installation guidelines.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUL (Underwriters Laboratories):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eEnsuring safety and performance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIEEE Standards:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor specific applications like VFDs.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eLocal Electrical Codes:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eLocal regulations for compliance.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eConductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eflexible red copper conductor Cl. 5, acc. to IEC 60228, DIN VDE 0295 and UL standard 83\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eInsulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003efrom 18 AWG up to 16 AWG: GAALTHERM 520 from 14 AWG and over: GAALTHERM 591\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eCores color:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+3g..: 3 black conductors numbered + 3 green-yellow conductors divided in 3 inertstices 3x..+1g.. \/ 4g..+(2x..) or 4g..+(2x..+2x..): black cores with consecutive numbers acc. to EN 50334 + green\/yellow\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eStranding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+1g..: cores twisted together + fillers 3x..+3g..: phase units laid up with earth-conductors in interstices 4g..+(2x..) or 4g..+(2x..+2x..): control cores twisted in pair(s) and screened, supply cores and control screened pair(s) twisted together\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIndividual screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e4g..+(2x..) or 4g..+(2x..+2x..): aluminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOverall screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ealuminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOuter Sheath:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eblack (similar RAL 9005), GAALTHERM 520\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUV resistant\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eoutdoor use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003einstallation in hazardous areas\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 2277 WTTC or Flexible Motor Supply\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 1277 (Oil-resistant according to UL OIL RES I and Water-resistant, UL 90°C Dry or 90°C Wet )\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUL only for TC-ER use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request c(UL) type CIC\/TC FT4, AWM I\/II A\/B FT4\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request DIRECT BURIAL\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to to NFPA 79 2007 and NEC 336.10(7) Class 1, Div. 2 Art. 336, 392, 501\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for application acc. to EN 55011, DIN VDE 0875 and EN 61800-3\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for chain application, see technical data*\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eRoHS and CE approval\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• No. of cores x cross section n x AWG\/MCM:\u003c\/strong\u003e 4 G 10 + (2 x 16)C\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Outer Ø inches\/mm ±10%:\u003c\/strong\u003e\u003cspan\u003e 0,72 - 18\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Nominal voltage:\u003c\/strong\u003e\u003cspan\u003e UL 1277 TC-ER-600 V, UL 2277 WTTC \/ Flexible Motor Supply-1000 V, IEC: Uo\/U 600\/1000 V\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Temperature range UL:\u003cspan\u003e  \u003c\/span\u003e\u003c\/strong\u003eup to 90°C Fixed laying: - 40 oC up to + 105 oC Flexible installation: - 5 oC up to + 105 oC\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Min. bending radius:\u003c\/strong\u003e\u003cspan\u003e Fixed laying: 6 x d Flexible application: 20 x d\u003cbr\u003e\u003cstrong\u003e• Copper weight Lbs\/Mft:\u003c\/strong\u003e 245,3 \u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Cable weight approx. Lbs\/Mft:\u003c\/strong\u003e\u003cspan\u003e 359,6\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e\u003cspan\u003e 33291F7004BA10\u003c\/span\u003e\u003c\/p\u003e","brand":"Elettrotek Kabel","offers":[{"title":"Default Title","offer_id":44265981640858,"sku":"33291F7004BA10","price":7.55,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/308_1a3bd369-0465-48fa-a3ac-ddff9574fec5.png?v=1762987924"},{"product_id":"8-4c-16-2c-bare-copper-shielded-al-tape-tc-braid-pvc-gaalflex-tray-vfd-1405-600v-cable","title":"8\/4C+16\/2C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/F2143-American-Industrial-Mining-Cables_removed_7.pdf?v=1703677301\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e8\/4C+16\/2C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 8\/4C+16\/2C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Gaalflex Bare Copper Shielded Al Tape TC Braid PVC Tray VFD 1405 600V Cable is a specialized cable designed for use in various industrial applications. It features a construction that includes bare copper conductors, shielding with aluminum tape and TC (Tinned Copper) braid, and a PVC jacket.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eGaalflex VFD 1405 600V Cable specifications\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eBare Copper Shielded Al Tape TC Braid PVC Tray Cable\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eInstrumentation cable standards\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eTray cable applications and usage\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eVFD cable for motor drives\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eShielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThis cable is shielded, which means it provides protection against electromagnetic interference (EMI) and radio-frequency interference (RFI). This shielding ensures stable and reliable signal transmission, critical for VFD systems.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eBare Copper Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe use of bare copper conductors ensures excellent electrical conductivity, reducing energy losses and allowing for efficient power transmission.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eAluminum Tape and TC Braid Shielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe combination of aluminum tape and tinned copper (TC) braid shielding provides enhanced protection against EMI and RFI, making it ideal for VFD applications where signal integrity is crucial.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003ePVC Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe PVC (Polyvinyl Chloride) jacket offers durability and resistance to environmental factors, making the cable suitable for both indoor and outdoor tray installations.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e600V Rating:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eWith a 600V rating, this cable can handle the voltage requirements of many VFD systems commonly used in industrial settings.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eNational Electrical Code (NEC):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor general electrical installation guidelines.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUL (Underwriters Laboratories):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eEnsuring safety and performance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIEEE Standards:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor specific applications like VFDs.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eLocal Electrical Codes:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eLocal regulations for compliance.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eConductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eflexible red copper conductor Cl. 5, acc. to IEC 60228, DIN VDE 0295 and UL standard 83\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eInsulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003efrom 18 AWG up to 16 AWG: GAALTHERM 520 from 14 AWG and over: GAALTHERM 591\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eCores color:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+3g..: 3 black conductors numbered + 3 green-yellow conductors divided in 3 inertstices 3x..+1g.. \/ 4g..+(2x..) or 4g..+(2x..+2x..): black cores with consecutive numbers acc. to EN 50334 + green\/yellow\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eStranding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+1g..: cores twisted together + fillers 3x..+3g..: phase units laid up with earth-conductors in interstices 4g..+(2x..) or 4g..+(2x..+2x..): control cores twisted in pair(s) and screened, supply cores and control screened pair(s) twisted together\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIndividual screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e4g..+(2x..) or 4g..+(2x..+2x..): aluminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOverall screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ealuminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOuter Sheath:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eblack (similar RAL 9005), GAALTHERM 520\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUV resistant\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eoutdoor use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003einstallation in hazardous areas\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 2277 WTTC or Flexible Motor Supply\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 1277 (Oil-resistant according to UL OIL RES I and Water-resistant, UL 90°C Dry or 90°C Wet )\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUL only for TC-ER use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request c(UL) type CIC\/TC FT4, AWM I\/II A\/B FT4\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request DIRECT BURIAL\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to to NFPA 79 2007 and NEC 336.10(7) Class 1, Div. 2 Art. 336, 392, 501\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for application acc. to EN 55011, DIN VDE 0875 and EN 61800-3\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for chain application, see technical data*\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eRoHS and CE approval\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• No. of cores x cross section n x AWG\/MCM:\u003c\/strong\u003e 4 G 8 + (2 x 16)C\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Outer Ø inches\/mm ±10%:\u003c\/strong\u003e\u003cspan\u003e 0,912 - 22,8\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Nominal voltage:\u003c\/strong\u003e\u003cspan\u003e UL 1277 TC-ER-600 V, UL 2277 WTTC \/ Flexible Motor Supply-1000 V, IEC: Uo\/U 600\/1000 V\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Temperature range UL:\u003cspan\u003e  \u003c\/span\u003e\u003c\/strong\u003eup to 90°C Fixed laying: - 40 oC up to + 105 oC Flexible installation: - 5 oC up to + 105 oC\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Min. bending radius:\u003c\/strong\u003e\u003cspan\u003e Fixed laying: 6 x d Flexible application: 20 x d\u003cbr\u003e\u003cstrong\u003e• Copper weight Lbs\/Mft:\u003c\/strong\u003e 366,9\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Cable weight approx. Lbs\/Mft:\u003c\/strong\u003e\u003cspan\u003e 567,9\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e\u003cspan\u003e 33291F7004BA08\u003c\/span\u003e\u003c\/p\u003e","brand":"Elettrotek Kabel","offers":[{"title":"Default Title","offer_id":44265986719898,"sku":"33291F7004BA08","price":10.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/308_b916fc8b-1d87-4b27-94aa-5f1677e43748.png?v=1759825846"},{"product_id":"6-4c-16-2c-bare-copper-shielded-al-tape-tc-braid-pvc-gaalflex-tray-vfd-1405-600v-cable","title":"6\/4C+16\/2C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/F2143-American-Industrial-Mining-Cables_removed_7.pdf?v=1703677301\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e6\/4C+16\/2C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 6\/4C+16\/2C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Gaalflex Bare Copper Shielded Al Tape TC Braid PVC Tray VFD 1405 600V Cable is a specialized cable designed for use in various industrial applications. It features a construction that includes bare copper conductors, shielding with aluminum tape and TC (Tinned Copper) braid, and a PVC jacket.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eGaalflex VFD 1405 600V Cable specifications\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eBare Copper Shielded Al Tape TC Braid PVC Tray Cable\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eInstrumentation cable standards\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eTray cable applications and usage\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eVFD cable for motor drives\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eShielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThis cable is shielded, which means it provides protection against electromagnetic interference (EMI) and radio-frequency interference (RFI). This shielding ensures stable and reliable signal transmission, critical for VFD systems.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eBare Copper Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe use of bare copper conductors ensures excellent electrical conductivity, reducing energy losses and allowing for efficient power transmission.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eAluminum Tape and TC Braid Shielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe combination of aluminum tape and tinned copper (TC) braid shielding provides enhanced protection against EMI and RFI, making it ideal for VFD applications where signal integrity is crucial.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003ePVC Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe PVC (Polyvinyl Chloride) jacket offers durability and resistance to environmental factors, making the cable suitable for both indoor and outdoor tray installations.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e600V Rating:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eWith a 600V rating, this cable can handle the voltage requirements of many VFD systems commonly used in industrial settings.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eNational Electrical Code (NEC):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor general electrical installation guidelines.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUL (Underwriters Laboratories):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eEnsuring safety and performance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIEEE Standards:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor specific applications like VFDs.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eLocal Electrical Codes:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eLocal regulations for compliance.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eConductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eflexible red copper conductor Cl. 5, acc. to IEC 60228, DIN VDE 0295 and UL standard 83\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eInsulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003efrom 18 AWG up to 16 AWG: GAALTHERM 520 from 14 AWG and over: GAALTHERM 591\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eCores color:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+3g..: 3 black conductors numbered + 3 green-yellow conductors divided in 3 inertstices 3x..+1g.. \/ 4g..+(2x..) or 4g..+(2x..+2x..): black cores with consecutive numbers acc. to EN 50334 + green\/yellow\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eStranding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+1g..: cores twisted together + fillers 3x..+3g..: phase units laid up with earth-conductors in interstices 4g..+(2x..) or 4g..+(2x..+2x..): control cores twisted in pair(s) and screened, supply cores and control screened pair(s) twisted together\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIndividual screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e4g..+(2x..) or 4g..+(2x..+2x..): aluminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOverall screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ealuminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOuter Sheath:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eblack (similar RAL 9005), GAALTHERM 520\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUV resistant\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eoutdoor use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003einstallation in hazardous areas\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 2277 WTTC or Flexible Motor Supply\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 1277 (Oil-resistant according to UL OIL RES I and Water-resistant, UL 90°C Dry or 90°C Wet )\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUL only for TC-ER use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request c(UL) type CIC\/TC FT4, AWM I\/II A\/B FT4\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request DIRECT BURIAL\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to to NFPA 79 2007 and NEC 336.10(7) Class 1, Div. 2 Art. 336, 392, 501\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for application acc. to EN 55011, DIN VDE 0875 and EN 61800-3\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for chain application, see technical data*\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eRoHS and CE approval\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• No. of cores x cross section n x AWG\/MCM:\u003c\/strong\u003e 4 G 6 + (2 x 16)C\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Outer Ø inches\/mm ±10%:\u003c\/strong\u003e\u003cspan\u003e 1 - 25\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Nominal voltage:\u003c\/strong\u003e\u003cspan\u003e UL 1277 TC-ER-600 V, UL 2277 WTTC \/ Flexible Motor Supply-1000 V, IEC: Uo\/U 600\/1000 V\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Temperature range UL:\u003cspan\u003e  \u003c\/span\u003e\u003c\/strong\u003eup to 90°C Fixed laying: - 40 oC up to + 105 oC Flexible installation: - 5 oC up to + 105 oC\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Min. bending radius:\u003c\/strong\u003e\u003cspan\u003e Fixed laying: 6 x d Flexible application: 20 x d\u003cbr\u003e\u003cstrong\u003e• Copper weight Lbs\/Mft:\u003c\/strong\u003e 528,9\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Cable weight approx. Lbs\/Mft:\u003c\/strong\u003e\u003cspan\u003e 747,9\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e\u003cspan\u003e 33291F7004BA06\u003c\/span\u003e\u003c\/p\u003e","brand":"Elettrotek Kabel","offers":[{"title":"Default Title","offer_id":44265994125466,"sku":"33291F7004BA06","price":14.16,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/308_d9566d65-baaa-433c-b095-d6e4dcbc5431.png?v=1759825848"},{"product_id":"14-4c-14-2c-bare-copper-shielded-al-tape-tc-braid-pvc-gaalflex-tray-vfd-1405-600v-cable","title":"14\/4C+14\/2C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/F2143-American-Industrial-Mining-Cables_removed_7.pdf?v=1703677301\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4\u003e\n\u003cstrong\u003e14\/4C+14\/2C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 14\/4C+14\/2C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Gaalflex Bare Copper Shielded Al Tape TC Braid PVC Tray VFD 1405 600V Cable is a specialized cable designed for use in various industrial applications. It features a construction that includes bare copper conductors, shielding with aluminum tape and TC (Tinned Copper) braid, and a PVC jacket.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eGaalflex VFD 1405 600V Cable specifications\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eBare Copper Shielded Al Tape TC Braid PVC Tray Cable\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eInstrumentation cable standards\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eTray cable applications and usage\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eVFD cable for motor drives\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eShielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThis cable is shielded, which means it provides protection against electromagnetic interference (EMI) and radio-frequency interference (RFI). This shielding ensures stable and reliable signal transmission, critical for VFD systems.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eBare Copper Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe use of bare copper conductors ensures excellent electrical conductivity, reducing energy losses and allowing for efficient power transmission.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eAluminum Tape and TC Braid Shielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe combination of aluminum tape and tinned copper (TC) braid shielding provides enhanced protection against EMI and RFI, making it ideal for VFD applications where signal integrity is crucial.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003ePVC Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe PVC (Polyvinyl Chloride) jacket offers durability and resistance to environmental factors, making the cable suitable for both indoor and outdoor tray installations.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e600V Rating:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eWith a 600V rating, this cable can handle the voltage requirements of many VFD systems commonly used in industrial settings.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eNational Electrical Code (NEC):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor general electrical installation guidelines.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUL (Underwriters Laboratories):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eEnsuring safety and performance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIEEE Standards:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor specific applications like VFDs.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eLocal Electrical Codes:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eLocal regulations for compliance.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eConductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eflexible red copper conductor Cl. 5, acc. to IEC 60228, DIN VDE 0295 and UL standard 83\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eInsulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003efrom 18 AWG up to 16 AWG: GAALTHERM 520 from 14 AWG and over: GAALTHERM 591\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eCores color:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+3g..: 3 black conductors numbered + 3 green-yellow conductors divided in 3 inertstices 3x..+1g.. \/ 4g..+(2x..) or 4g..+(2x..+2x..): black cores with consecutive numbers acc. to EN 50334 + green\/yellow\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eStranding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+1g..: cores twisted together + fillers 3x..+3g..: phase units laid up with earth-conductors in interstices 4g..+(2x..) or 4g..+(2x..+2x..): control cores twisted in pair(s) and screened, supply cores and control screened pair(s) twisted together\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIndividual screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e4g..+(2x..) or 4g..+(2x..+2x..): aluminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOverall screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ealuminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOuter Sheath:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eblack (similar RAL 9005), GAALTHERM 520\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUV resistant\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eoutdoor use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003einstallation in hazardous areas\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 2277 WTTC or Flexible Motor Supply\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 1277 (Oil-resistant according to UL OIL RES I and Water-resistant, UL 90°C Dry or 90°C Wet )\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUL only for TC-ER use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request c(UL) type CIC\/TC FT4, AWM I\/II A\/B FT4\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request DIRECT BURIAL\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to to NFPA 79 2007 and NEC 336.10(7) Class 1, Div. 2 Art. 336, 392, 501\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for application acc. to EN 55011, DIN VDE 0875 and EN 61800-3\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for chain application, see technical data*\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eRoHS and CE approval\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• No. of cores x cross section n x AWG\/MCM:\u003c\/strong\u003e 4 G 14 + (2 x 14)C\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Outer Ø inches\/mm ±10%:\u003c\/strong\u003e\u003cspan\u003e 0,638 - 16,2 \u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Nominal voltage:\u003c\/strong\u003e\u003cspan\u003e UL 1277 TC-ER-600 V, UL 2277 WTTC \/ Flexible Motor Supply-1000 V, IEC: Uo\/U 600\/1000 V\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Temperature range UL:\u003cspan\u003e  \u003c\/span\u003e\u003c\/strong\u003eup to 90°C Fixed laying: - 40 oC up to + 105 oC Flexible installation: - 5 oC up to + 105 oC\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Min. bending radius:\u003c\/strong\u003e\u003cspan\u003e Fixed laying: 6 x d Flexible application: 20 x d\u003cbr\u003e\u003cstrong\u003e• Copper weight Lbs\/Mft:\u003c\/strong\u003e 162,6 \u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Cable weight approx. Lbs\/Mft:\u003c\/strong\u003e\u003cspan\u003e 256,7\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e\u003cspan\u003e 33292F7004BA14\u003c\/span\u003e\u003c\/p\u003e","brand":"Elettrotek Kabel","offers":[{"title":"Default Title","offer_id":44265995206810,"sku":"33292F7004BA14","price":5.38,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/308_4329e559-10ff-4ef7-963a-60898ca98a0f.png?v=1762987929"},{"product_id":"12-4c-14-2c-bare-copper-shielded-al-tape-tc-braid-pvc-gaalflex-tray-vfd-1405-600v-cable","title":"12\/4C+14\/2C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/F2143-American-Industrial-Mining-Cables_removed_7.pdf?v=1703677301\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4\u003e\n\u003cstrong\u003e12\/4C+14\/2C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 12\/4C+14\/2C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Gaalflex Bare Copper Shielded Al Tape TC Braid PVC Tray VFD 1405 600V Cable is a specialized cable designed for use in various industrial applications. It features a construction that includes bare copper conductors, shielding with aluminum tape and TC (Tinned Copper) braid, and a PVC jacket.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eGaalflex VFD 1405 600V Cable specifications\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eBare Copper Shielded Al Tape TC Braid PVC Tray Cable\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eInstrumentation cable standards\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eTray cable applications and usage\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eVFD cable for motor drives\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eShielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThis cable is shielded, which means it provides protection against electromagnetic interference (EMI) and radio-frequency interference (RFI). This shielding ensures stable and reliable signal transmission, critical for VFD systems.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eBare Copper Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe use of bare copper conductors ensures excellent electrical conductivity, reducing energy losses and allowing for efficient power transmission.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eAluminum Tape and TC Braid Shielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe combination of aluminum tape and tinned copper (TC) braid shielding provides enhanced protection against EMI and RFI, making it ideal for VFD applications where signal integrity is crucial.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003ePVC Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe PVC (Polyvinyl Chloride) jacket offers durability and resistance to environmental factors, making the cable suitable for both indoor and outdoor tray installations.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e600V Rating:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eWith a 600V rating, this cable can handle the voltage requirements of many VFD systems commonly used in industrial settings.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eNational Electrical Code (NEC):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor general electrical installation guidelines.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUL (Underwriters Laboratories):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eEnsuring safety and performance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIEEE Standards:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor specific applications like VFDs.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eLocal Electrical Codes:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eLocal regulations for compliance.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eConductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eflexible red copper conductor Cl. 5, acc. to IEC 60228, DIN VDE 0295 and UL standard 83\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eInsulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003efrom 18 AWG up to 16 AWG: GAALTHERM 520 from 14 AWG and over: GAALTHERM 591\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eCores color:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+3g..: 3 black conductors numbered + 3 green-yellow conductors divided in 3 inertstices 3x..+1g.. \/ 4g..+(2x..) or 4g..+(2x..+2x..): black cores with consecutive numbers acc. to EN 50334 + green\/yellow\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eStranding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+1g..: cores twisted together + fillers 3x..+3g..: phase units laid up with earth-conductors in interstices 4g..+(2x..) or 4g..+(2x..+2x..): control cores twisted in pair(s) and screened, supply cores and control screened pair(s) twisted together\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIndividual screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e4g..+(2x..) or 4g..+(2x..+2x..): aluminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOverall screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ealuminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOuter Sheath:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eblack (similar RAL 9005), GAALTHERM 520\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUV resistant\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eoutdoor use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003einstallation in hazardous areas\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 2277 WTTC or Flexible Motor Supply\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 1277 (Oil-resistant according to UL OIL RES I and Water-resistant, UL 90°C Dry or 90°C Wet )\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUL only for TC-ER use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request c(UL) type CIC\/TC FT4, AWM I\/II A\/B FT4\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request DIRECT BURIAL\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to to NFPA 79 2007 and NEC 336.10(7) Class 1, Div. 2 Art. 336, 392, 501\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for application acc. to EN 55011, DIN VDE 0875 and EN 61800-3\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for chain application, see technical data*\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eRoHS and CE approval\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• No. of cores x cross section n x AWG\/MCM:\u003c\/strong\u003e 4 G 12 + (2 x 14)C\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Outer Ø inches\/mm ±10%:\u003c\/strong\u003e\u003cspan\u003e 0,697 - 17,7\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Nominal voltage:\u003c\/strong\u003e\u003cspan\u003e UL 1277 TC-ER-600 V, UL 2277 WTTC \/ Flexible Motor Supply-1000 V, IEC: Uo\/U 600\/1000 V\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Temperature range UL:\u003cspan\u003e  \u003c\/span\u003e\u003c\/strong\u003eup to 90°C Fixed laying: - 40 oC up to + 105 oC Flexible installation: - 5 oC up to + 105 oC\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Min. bending radius:\u003c\/strong\u003e\u003cspan\u003e Fixed laying: 6 x d Flexible application: 20 x d\u003cbr\u003e\u003cstrong\u003e• Copper weight Lbs\/Mft:\u003c\/strong\u003e 207\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Cable weight approx. Lbs\/Mft:\u003c\/strong\u003e\u003cspan\u003e 309,8\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e\u003cspan\u003e 33292F7004BA12\u003c\/span\u003e\u003c\/p\u003e","brand":"Elettrotek Kabel","offers":[{"title":"Default Title","offer_id":44266048913562,"sku":"33292F7004BA12","price":6.33,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/308_ae82f23a-ef45-4c12-bfb4-461ad5d61aa3.png?v=1762987939"},{"product_id":"31-10-4c-14-2c-bare-copper-shielded-al-tape-tc-braid-pvc-gaalflex-tray-vfd-1405-600v-cable","title":"31' 10\/4C+14\/2C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/F2143-American-Industrial-Mining-Cables_removed_7.pdf?v=1703677301\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4\u003e\n\u003cstrong\u003e10\/4C+14\/2C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 10\/4C+14\/2C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Gaalflex Bare Copper Shielded Al Tape TC Braid PVC Tray VFD 1405 600V Cable is a specialized cable designed for use in various industrial applications. It features a construction that includes bare copper conductors, shielding with aluminum tape and TC (Tinned Copper) braid, and a PVC jacket.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eGaalflex VFD 1405 600V Cable specifications\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eBare Copper Shielded Al Tape TC Braid PVC Tray Cable\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eInstrumentation cable standards\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eTray cable applications and usage\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eVFD cable for motor drives\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eShielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThis cable is shielded, which means it provides protection against electromagnetic interference (EMI) and radio-frequency interference (RFI). This shielding ensures stable and reliable signal transmission, critical for VFD systems.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eBare Copper Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe use of bare copper conductors ensures excellent electrical conductivity, reducing energy losses and allowing for efficient power transmission.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eAluminum Tape and TC Braid Shielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe combination of aluminum tape and tinned copper (TC) braid shielding provides enhanced protection against EMI and RFI, making it ideal for VFD applications where signal integrity is crucial.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003ePVC Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe PVC (Polyvinyl Chloride) jacket offers durability and resistance to environmental factors, making the cable suitable for both indoor and outdoor tray installations.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e600V Rating:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eWith a 600V rating, this cable can handle the voltage requirements of many VFD systems commonly used in industrial settings.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eNational Electrical Code (NEC):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor general electrical installation guidelines.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUL (Underwriters Laboratories):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eEnsuring safety and performance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIEEE Standards:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor specific applications like VFDs.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eLocal Electrical Codes:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eLocal regulations for compliance.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eConductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eflexible red copper conductor Cl. 5, acc. to IEC 60228, DIN VDE 0295 and UL standard 83\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eInsulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003efrom 18 AWG up to 16 AWG: GAALTHERM 520 from 14 AWG and over: GAALTHERM 591\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eCores color:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+3g..: 3 black conductors numbered + 3 green-yellow conductors divided in 3 inertstices 3x..+1g.. \/ 4g..+(2x..) or 4g..+(2x..+2x..): black cores with consecutive numbers acc. to EN 50334 + green\/yellow\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eStranding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+1g..: cores twisted together + fillers 3x..+3g..: phase units laid up with earth-conductors in interstices 4g..+(2x..) or 4g..+(2x..+2x..): control cores twisted in pair(s) and screened, supply cores and control screened pair(s) twisted together\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIndividual screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e4g..+(2x..) or 4g..+(2x..+2x..): aluminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOverall screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ealuminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOuter Sheath:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eblack (similar RAL 9005), GAALTHERM 520\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUV resistant\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eoutdoor use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003einstallation in hazardous areas\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 2277 WTTC or Flexible Motor Supply\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 1277 (Oil-resistant according to UL OIL RES I and Water-resistant, UL 90°C Dry or 90°C Wet )\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUL only for TC-ER use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request c(UL) type CIC\/TC FT4, AWM I\/II A\/B FT4\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request DIRECT BURIAL\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to to NFPA 79 2007 and NEC 336.10(7) Class 1, Div. 2 Art. 336, 392, 501\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for application acc. to EN 55011, DIN VDE 0875 and EN 61800-3\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for chain application, see technical data*\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eRoHS and CE approval\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• No. of cores x cross section n x AWG\/MCM:\u003c\/strong\u003e 4 G 10 + (2 x 14)C\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Outer Ø inches\/mm ±10%:\u003c\/strong\u003e\u003cspan\u003e 0,744 - 18,9\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Nominal voltage:\u003c\/strong\u003e\u003cspan\u003e UL 1277 TC-ER-600 V, UL 2277 WTTC \/ Flexible Motor Supply-1000 V, IEC: Uo\/U 600\/1000 V\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Temperature range UL:\u003cspan\u003e  \u003c\/span\u003e\u003c\/strong\u003eup to 90°C Fixed laying: - 40 oC up to + 105 oC Flexible installation: - 5 oC up to + 105 oC\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Min. bending radius:\u003c\/strong\u003e\u003cspan\u003e Fixed laying: 6 x d Flexible application: 20 x d\u003cbr\u003e\u003cstrong\u003e• Copper weight Lbs\/Mft:\u003c\/strong\u003e 264,1\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Cable weight approx. Lbs\/Mft:\u003c\/strong\u003e\u003cspan\u003e 323,9\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e\u003cspan\u003e 33292F7004BA10\u003c\/span\u003e\u003c\/p\u003e","brand":"Elettrotek Kabel","offers":[{"title":"Default Title","offer_id":44266052944026,"sku":"33292F7004BA1031","price":242.04,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/308_ae3d17ee-52ec-45aa-8b30-e5a42b4a5f8a.png?v=1762987939"},{"product_id":"8-4c-14-2c-bare-copper-shielded-al-tape-tc-braid-pvc-gaalflex-tray-vfd-1405-600v-cable","title":"8\/4C+14\/2C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/F2143-American-Industrial-Mining-Cables_removed_7.pdf?v=1703677301\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4\u003e\n\u003cstrong\u003e8\/4C+14\/2C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 8\/4C+14\/2C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Gaalflex Bare Copper Shielded Al Tape TC Braid PVC Tray VFD 1405 600V Cable is a specialized cable designed for use in various industrial applications. It features a construction that includes bare copper conductors, shielding with aluminum tape and TC (Tinned Copper) braid, and a PVC jacket.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eGaalflex VFD 1405 600V Cable specifications\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eBare Copper Shielded Al Tape TC Braid PVC Tray Cable\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eInstrumentation cable standards\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eTray cable applications and usage\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eVFD cable for motor drives\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eShielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThis cable is shielded, which means it provides protection against electromagnetic interference (EMI) and radio-frequency interference (RFI). This shielding ensures stable and reliable signal transmission, critical for VFD systems.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eBare Copper Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe use of bare copper conductors ensures excellent electrical conductivity, reducing energy losses and allowing for efficient power transmission.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eAluminum Tape and TC Braid Shielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe combination of aluminum tape and tinned copper (TC) braid shielding provides enhanced protection against EMI and RFI, making it ideal for VFD applications where signal integrity is crucial.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003ePVC Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe PVC (Polyvinyl Chloride) jacket offers durability and resistance to environmental factors, making the cable suitable for both indoor and outdoor tray installations.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e600V Rating:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eWith a 600V rating, this cable can handle the voltage requirements of many VFD systems commonly used in industrial settings.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eNational Electrical Code (NEC):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor general electrical installation guidelines.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUL (Underwriters Laboratories):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eEnsuring safety and performance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIEEE Standards:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor specific applications like VFDs.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eLocal Electrical Codes:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eLocal regulations for compliance.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eConductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eflexible red copper conductor Cl. 5, acc. to IEC 60228, DIN VDE 0295 and UL standard 83\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eInsulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003efrom 18 AWG up to 16 AWG: GAALTHERM 520 from 14 AWG and over: GAALTHERM 591\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eCores color:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+3g..: 3 black conductors numbered + 3 green-yellow conductors divided in 3 inertstices 3x..+1g.. \/ 4g..+(2x..) or 4g..+(2x..+2x..): black cores with consecutive numbers acc. to EN 50334 + green\/yellow\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eStranding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+1g..: cores twisted together + fillers 3x..+3g..: phase units laid up with earth-conductors in interstices 4g..+(2x..) or 4g..+(2x..+2x..): control cores twisted in pair(s) and screened, supply cores and control screened pair(s) twisted together\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIndividual screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e4g..+(2x..) or 4g..+(2x..+2x..): aluminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOverall screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ealuminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOuter Sheath:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eblack (similar RAL 9005), GAALTHERM 520\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUV resistant\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eoutdoor use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003einstallation in hazardous areas\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 2277 WTTC or Flexible Motor Supply\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 1277 (Oil-resistant according to UL OIL RES I and Water-resistant, UL 90°C Dry or 90°C Wet )\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUL only for TC-ER use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request c(UL) type CIC\/TC FT4, AWM I\/II A\/B FT4\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request DIRECT BURIAL\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to to NFPA 79 2007 and NEC 336.10(7) Class 1, Div. 2 Art. 336, 392, 501\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for application acc. to EN 55011, DIN VDE 0875 and EN 61800-3\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for chain application, see technical data*\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eRoHS and CE approval\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• No. of cores x cross section n x AWG\/MCM:\u003c\/strong\u003e 4 G 8 + (2 x 14)C\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Outer Ø inches\/mm ±10%:\u003c\/strong\u003e\u003cspan\u003e 0,913 - 23,2\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Nominal voltage:\u003c\/strong\u003e\u003cspan\u003e UL 1277 TC-ER-600 V, UL 2277 WTTC \/ Flexible Motor Supply-1000 V, IEC: Uo\/U 600\/1000 V\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Temperature range UL:\u003cspan\u003e  \u003c\/span\u003e\u003c\/strong\u003eup to 90°C Fixed laying: - 40 oC up to + 105 oC Flexible installation: - 5 oC up to + 105 oC\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Min. bending radius:\u003c\/strong\u003e\u003cspan\u003e Fixed laying: 6 x d Flexible application: 20 x d\u003cbr\u003e\u003cstrong\u003e• Copper weight Lbs\/Mft:\u003c\/strong\u003e 384,4\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Cable weight approx. Lbs\/Mft:\u003c\/strong\u003e\u003cspan\u003e 514,8\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e\u003cspan\u003e 33292F7004BA08\u003c\/span\u003e\u003c\/p\u003e","brand":"Elettrotek Kabel","offers":[{"title":"Default Title","offer_id":44266155016346,"sku":"33292F7004BA08","price":11.51,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/308_03abae2b-9ef6-48c3-9179-d7bcb731abfe.png?v=1759825851"},{"product_id":"6-4c-14-2c-bare-copper-shielded-al-tape-tc-braid-pvc-gaalflex-tray-vfd-1405-600v-cable","title":"6\/4C+14\/2C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/F2143-American-Industrial-Mining-Cables_removed_7.pdf?v=1703677301\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4\u003e\n\u003cstrong\u003e6\/4C+14\/2C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 6\/4C+14\/2C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Gaalflex Bare Copper Shielded Al Tape TC Braid PVC Tray VFD 1405 600V Cable is a specialized cable designed for use in various industrial applications. It features a construction that includes bare copper conductors, shielding with aluminum tape and TC (Tinned Copper) braid, and a PVC jacket.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eGaalflex VFD 1405 600V Cable specifications\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eBare Copper Shielded Al Tape TC Braid PVC Tray Cable\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eInstrumentation cable standards\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eTray cable applications and usage\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eVFD cable for motor drives\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eShielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThis cable is shielded, which means it provides protection against electromagnetic interference (EMI) and radio-frequency interference (RFI). This shielding ensures stable and reliable signal transmission, critical for VFD systems.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eBare Copper Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe use of bare copper conductors ensures excellent electrical conductivity, reducing energy losses and allowing for efficient power transmission.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eAluminum Tape and TC Braid Shielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe combination of aluminum tape and tinned copper (TC) braid shielding provides enhanced protection against EMI and RFI, making it ideal for VFD applications where signal integrity is crucial.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003ePVC Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe PVC (Polyvinyl Chloride) jacket offers durability and resistance to environmental factors, making the cable suitable for both indoor and outdoor tray installations.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e600V Rating:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eWith a 600V rating, this cable can handle the voltage requirements of many VFD systems commonly used in industrial settings.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eNational Electrical Code (NEC):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor general electrical installation guidelines.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUL (Underwriters Laboratories):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eEnsuring safety and performance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIEEE Standards:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor specific applications like VFDs.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eLocal Electrical Codes:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eLocal regulations for compliance.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eConductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eflexible red copper conductor Cl. 5, acc. to IEC 60228, DIN VDE 0295 and UL standard 83\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eInsulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003efrom 18 AWG up to 16 AWG: GAALTHERM 520 from 14 AWG and over: GAALTHERM 591\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eCores color:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+3g..: 3 black conductors numbered + 3 green-yellow conductors divided in 3 inertstices 3x..+1g.. \/ 4g..+(2x..) or 4g..+(2x..+2x..): black cores with consecutive numbers acc. to EN 50334 + green\/yellow\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eStranding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+1g..: cores twisted together + fillers 3x..+3g..: phase units laid up with earth-conductors in interstices 4g..+(2x..) or 4g..+(2x..+2x..): control cores twisted in pair(s) and screened, supply cores and control screened pair(s) twisted together\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIndividual screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e4g..+(2x..) or 4g..+(2x..+2x..): aluminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOverall screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ealuminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOuter Sheath:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eblack (similar RAL 9005), GAALTHERM 520\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUV resistant\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eoutdoor use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003einstallation in hazardous areas\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 2277 WTTC or Flexible Motor Supply\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 1277 (Oil-resistant according to UL OIL RES I and Water-resistant, UL 90°C Dry or 90°C Wet )\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUL only for TC-ER use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request c(UL) type CIC\/TC FT4, AWM I\/II A\/B FT4\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request DIRECT BURIAL\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to to NFPA 79 2007 and NEC 336.10(7) Class 1, Div. 2 Art. 336, 392, 501\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for application acc. to EN 55011, DIN VDE 0875 and EN 61800-3\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for chain application, see technical data*\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eRoHS and CE approval\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• No. of cores x cross section n x AWG\/MCM:\u003c\/strong\u003e 4 G 6 + (2 x 14)C\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Outer Ø inches\/mm ±10%:\u003c\/strong\u003e\u003cspan\u003e 1,012 - 25,7\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Nominal voltage:\u003c\/strong\u003e\u003cspan\u003e UL 1277 TC-ER-600 V, UL 2277 WTTC \/ Flexible Motor Supply-1000 V, IEC: Uo\/U 600\/1000 V\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Temperature range UL:\u003cspan\u003e  \u003c\/span\u003e\u003c\/strong\u003eup to 90°C Fixed laying: - 40 oC up to + 105 oC Flexible installation: - 5 oC up to + 105 oC\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Min. bending radius:\u003c\/strong\u003e\u003cspan\u003e Fixed laying: 6 x d Flexible application: 20 x d\u003cbr\u003e\u003cstrong\u003e• Copper weight Lbs\/Mft:\u003c\/strong\u003e 545\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Cable weight approx. Lbs\/Mft:\u003c\/strong\u003e\u003cspan\u003e 708,3\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e\u003cspan\u003e 33292F7004BA06\u003c\/span\u003e\u003c\/p\u003e","brand":"Elettrotek Kabel","offers":[{"title":"Default Title","offer_id":44266169499802,"sku":"33292F7004BA06","price":15.77,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/308_b7a9bb5e-18c3-4f57-9dd7-47d7f8f18560.png?v=1759825852"},{"product_id":"4-4c-14-2c-bare-copper-shielded-al-tape-tc-braid-pvc-gaalflex-tray-vfd-1405-600v-cable","title":"4\/4C+14\/2C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/F2143-American-Industrial-Mining-Cables_removed_7.pdf?v=1703677301\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4\u003e\n\u003cstrong\u003e4\/4C+14\/2C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 4\/4C+14\/2C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Gaalflex Bare Copper Shielded Al Tape TC Braid PVC Tray VFD 1405 600V Cable is a specialized cable designed for use in various industrial applications. It features a construction that includes bare copper conductors, shielding with aluminum tape and TC (Tinned Copper) braid, and a PVC jacket.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eGaalflex VFD 1405 600V Cable specifications\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eBare Copper Shielded Al Tape TC Braid PVC Tray Cable\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eInstrumentation cable standards\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eTray cable applications and usage\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eVFD cable for motor drives\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eShielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThis cable is shielded, which means it provides protection against electromagnetic interference (EMI) and radio-frequency interference (RFI). This shielding ensures stable and reliable signal transmission, critical for VFD systems.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eBare Copper Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe use of bare copper conductors ensures excellent electrical conductivity, reducing energy losses and allowing for efficient power transmission.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eAluminum Tape and TC Braid Shielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe combination of aluminum tape and tinned copper (TC) braid shielding provides enhanced protection against EMI and RFI, making it ideal for VFD applications where signal integrity is crucial.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003ePVC Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe PVC (Polyvinyl Chloride) jacket offers durability and resistance to environmental factors, making the cable suitable for both indoor and outdoor tray installations.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e600V Rating:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eWith a 600V rating, this cable can handle the voltage requirements of many VFD systems commonly used in industrial settings.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eNational Electrical Code (NEC):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor general electrical installation guidelines.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUL (Underwriters Laboratories):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eEnsuring safety and performance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIEEE Standards:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor specific applications like VFDs.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eLocal Electrical Codes:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eLocal regulations for compliance.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eConductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eflexible red copper conductor Cl. 5, acc. to IEC 60228, DIN VDE 0295 and UL standard 83\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eInsulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003efrom 18 AWG up to 16 AWG: GAALTHERM 520 from 14 AWG and over: GAALTHERM 591\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eCores color:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+3g..: 3 black conductors numbered + 3 green-yellow conductors divided in 3 inertstices 3x..+1g.. \/ 4g..+(2x..) or 4g..+(2x..+2x..): black cores with consecutive numbers acc. to EN 50334 + green\/yellow\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eStranding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+1g..: cores twisted together + fillers 3x..+3g..: phase units laid up with earth-conductors in interstices 4g..+(2x..) or 4g..+(2x..+2x..): control cores twisted in pair(s) and screened, supply cores and control screened pair(s) twisted together\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIndividual screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e4g..+(2x..) or 4g..+(2x..+2x..): aluminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOverall screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ealuminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOuter Sheath:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eblack (similar RAL 9005), GAALTHERM 520\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUV resistant\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eoutdoor use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003einstallation in hazardous areas\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 2277 WTTC or Flexible Motor Supply\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 1277 (Oil-resistant according to UL OIL RES I and Water-resistant, UL 90°C Dry or 90°C Wet )\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUL only for TC-ER use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request c(UL) type CIC\/TC FT4, AWM I\/II A\/B FT4\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request DIRECT BURIAL\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to to NFPA 79 2007 and NEC 336.10(7) Class 1, Div. 2 Art. 336, 392, 501\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for application acc. to EN 55011, DIN VDE 0875 and EN 61800-3\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for chain application, see technical data*\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eRoHS and CE approval\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• No. of cores x cross section n x AWG\/MCM:\u003c\/strong\u003e 4 G 4 + (2 x 14)C\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Outer Ø inches\/mm ±10%:\u003c\/strong\u003e\u003cspan\u003e 1,138 - 28,9\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Nominal voltage:\u003c\/strong\u003e\u003cspan\u003e UL 1277 TC-ER-600 V, UL 2277 WTTC \/ Flexible Motor Supply-1000 V, IEC: Uo\/U 600\/1000 V\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Temperature range UL:\u003cspan\u003e  \u003c\/span\u003e\u003c\/strong\u003eup to 90°C Fixed laying: - 40 oC up to + 105 oC Flexible installation: - 5 oC up to + 105 oC\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Min. bending radius:\u003c\/strong\u003e\u003cspan\u003e Fixed laying: 6 x d Flexible application: 20 x d\u003cbr\u003e\u003cstrong\u003e• Copper weight Lbs\/Mft:\u003c\/strong\u003e 788,9\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Cable weight approx. Lbs\/Mft:\u003c\/strong\u003e\u003cspan\u003e 992,5\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e\u003cspan\u003e 33292F7004BA04 \u003c\/span\u003e\u003c\/p\u003e","brand":"Elettrotek Kabel","offers":[{"title":"Default Title","offer_id":44266184933530,"sku":"33292F7004BA04","price":22.04,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/308_9819b5ab-5304-4317-9be2-5e957d2fb4ae.png?v=1762987950"},{"product_id":"2-4c-14-2c-bare-copper-shielded-al-tape-tc-braid-pvc-gaalflex-tray-vfd-1405-600v-cable","title":"2\/4C+14\/2C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/F2143-American-Industrial-Mining-Cables_removed_7.pdf?v=1703677301\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4\u003e\n\u003cstrong\u003e2\/4C+14\/2C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 2\/4C+14\/2C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Gaalflex Bare Copper Shielded Al Tape TC Braid PVC Tray VFD 1405 600V Cable is a specialized cable designed for use in various industrial applications. It features a construction that includes bare copper conductors, shielding with aluminum tape and TC (Tinned Copper) braid, and a PVC jacket.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eGaalflex VFD 1405 600V Cable specifications\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eBare Copper Shielded Al Tape TC Braid PVC Tray Cable\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eInstrumentation cable standards\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eTray cable applications and usage\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eVFD cable for motor drives\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eShielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThis cable is shielded, which means it provides protection against electromagnetic interference (EMI) and radio-frequency interference (RFI). This shielding ensures stable and reliable signal transmission, critical for VFD systems.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eBare Copper Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe use of bare copper conductors ensures excellent electrical conductivity, reducing energy losses and allowing for efficient power transmission.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eAluminum Tape and TC Braid Shielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe combination of aluminum tape and tinned copper (TC) braid shielding provides enhanced protection against EMI and RFI, making it ideal for VFD applications where signal integrity is crucial.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003ePVC Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe PVC (Polyvinyl Chloride) jacket offers durability and resistance to environmental factors, making the cable suitable for both indoor and outdoor tray installations.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e600V Rating:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eWith a 600V rating, this cable can handle the voltage requirements of many VFD systems commonly used in industrial settings.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eNational Electrical Code (NEC):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor general electrical installation guidelines.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUL (Underwriters Laboratories):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eEnsuring safety and performance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIEEE Standards:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor specific applications like VFDs.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eLocal Electrical Codes:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eLocal regulations for compliance.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eConductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eflexible red copper conductor Cl. 5, acc. to IEC 60228, DIN VDE 0295 and UL standard 83\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eInsulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003efrom 18 AWG up to 16 AWG: GAALTHERM 520 from 14 AWG and over: GAALTHERM 591\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eCores color:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+3g..: 3 black conductors numbered + 3 green-yellow conductors divided in 3 inertstices 3x..+1g.. \/ 4g..+(2x..) or 4g..+(2x..+2x..): black cores with consecutive numbers acc. to EN 50334 + green\/yellow\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eStranding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+1g..: cores twisted together + fillers 3x..+3g..: phase units laid up with earth-conductors in interstices 4g..+(2x..) or 4g..+(2x..+2x..): control cores twisted in pair(s) and screened, supply cores and control screened pair(s) twisted together\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIndividual screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e4g..+(2x..) or 4g..+(2x..+2x..): aluminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOverall screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ealuminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOuter Sheath:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eblack (similar RAL 9005), GAALTHERM 520\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUV resistant\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eoutdoor use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003einstallation in hazardous areas\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 2277 WTTC or Flexible Motor Supply\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 1277 (Oil-resistant according to UL OIL RES I and Water-resistant, UL 90°C Dry or 90°C Wet )\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUL only for TC-ER use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request c(UL) type CIC\/TC FT4, AWM I\/II A\/B FT4\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request DIRECT BURIAL\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to to NFPA 79 2007 and NEC 336.10(7) Class 1, Div. 2 Art. 336, 392, 501\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for application acc. to EN 55011, DIN VDE 0875 and EN 61800-3\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for chain application, see technical data*\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eRoHS and CE approval\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• No. of cores x cross section n x AWG\/MCM:\u003c\/strong\u003e 4 G 2 + (2 x 14)C\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Outer Ø inches\/mm ±10%:\u003c\/strong\u003e\u003cspan\u003e 1,268 - 32,2\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Nominal voltage:\u003c\/strong\u003e\u003cspan\u003e UL 1277 TC-ER-600 V, UL 2277 WTTC \/ Flexible Motor Supply-1000 V, IEC: Uo\/U 600\/1000 V\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Temperature range UL:\u003cspan\u003e  \u003c\/span\u003e\u003c\/strong\u003eup to 90°C Fixed laying: - 40 oC up to + 105 oC Flexible installation: - 5 oC up to + 105 oC\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Min. bending radius:\u003c\/strong\u003e\u003cspan\u003e Fixed laying: 6 x d Flexible application: 20 x d\u003cbr\u003e\u003cstrong\u003e• Copper weight Lbs\/Mft:\u003c\/strong\u003e 1058,4\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Cable weight approx. Lbs\/Mft:\u003c\/strong\u003e\u003cspan\u003e 1297\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e\u003cspan\u003e 33292F7004BA02\u003c\/span\u003e\u003c\/p\u003e","brand":"Elettrotek Kabel","offers":[{"title":"Default Title","offer_id":44266409394330,"sku":"33292F7004BA02","price":29.09,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/308_8d667d29-e1e4-4c17-a80b-382b3ab48ed6.png?v=1759825859"},{"product_id":"1-4c-14-2c-bare-copper-shielded-al-tape-tc-braid-pvc-gaalflex-tray-vfd-1405-600v-cable","title":"1\/4C+14\/2C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/F2143-American-Industrial-Mining-Cables_removed_7.pdf?v=1703677301\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4\u003e\n\u003cstrong\u003e1\/4C+14\/2C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 1\/4C+14\/2C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Gaalflex Bare Copper Shielded Al Tape TC Braid PVC Tray VFD 1405 600V Cable is a specialized cable designed for use in various industrial applications. It features a construction that includes bare copper conductors, shielding with aluminum tape and TC (Tinned Copper) braid, and a PVC jacket.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eGaalflex VFD 1405 600V Cable specifications\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eBare Copper Shielded Al Tape TC Braid PVC Tray Cable\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eInstrumentation cable standards\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eTray cable applications and usage\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eVFD cable for motor drives\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eShielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThis cable is shielded, which means it provides protection against electromagnetic interference (EMI) and radio-frequency interference (RFI). This shielding ensures stable and reliable signal transmission, critical for VFD systems.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eBare Copper Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe use of bare copper conductors ensures excellent electrical conductivity, reducing energy losses and allowing for efficient power transmission.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eAluminum Tape and TC Braid Shielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe combination of aluminum tape and tinned copper (TC) braid shielding provides enhanced protection against EMI and RFI, making it ideal for VFD applications where signal integrity is crucial.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003ePVC Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe PVC (Polyvinyl Chloride) jacket offers durability and resistance to environmental factors, making the cable suitable for both indoor and outdoor tray installations.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e600V Rating:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eWith a 600V rating, this cable can handle the voltage requirements of many VFD systems commonly used in industrial settings.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eNational Electrical Code (NEC):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor general electrical installation guidelines.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUL (Underwriters Laboratories):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eEnsuring safety and performance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIEEE Standards:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor specific applications like VFDs.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eLocal Electrical Codes:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eLocal regulations for compliance.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eConductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eflexible red copper conductor Cl. 5, acc. to IEC 60228, DIN VDE 0295 and UL standard 83\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eInsulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003efrom 18 AWG up to 16 AWG: GAALTHERM 520 from 14 AWG and over: GAALTHERM 591\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eCores color:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+3g..: 3 black conductors numbered + 3 green-yellow conductors divided in 3 inertstices 3x..+1g.. \/ 4g..+(2x..) or 4g..+(2x..+2x..): black cores with consecutive numbers acc. to EN 50334 + green\/yellow\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eStranding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+1g..: cores twisted together + fillers 3x..+3g..: phase units laid up with earth-conductors in interstices 4g..+(2x..) or 4g..+(2x..+2x..): control cores twisted in pair(s) and screened, supply cores and control screened pair(s) twisted together\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIndividual screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e4g..+(2x..) or 4g..+(2x..+2x..): aluminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOverall screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ealuminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOuter Sheath:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eblack (similar RAL 9005), GAALTHERM 520\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUV resistant\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eoutdoor use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003einstallation in hazardous areas\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 2277 WTTC or Flexible Motor Supply\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 1277 (Oil-resistant according to UL OIL RES I and Water-resistant, UL 90°C Dry or 90°C Wet )\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUL only for TC-ER use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request c(UL) type CIC\/TC FT4, AWM I\/II A\/B FT4\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request DIRECT BURIAL\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to to NFPA 79 2007 and NEC 336.10(7) Class 1, Div. 2 Art. 336, 392, 501\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for application acc. to EN 55011, DIN VDE 0875 and EN 61800-3\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for chain application, see technical data*\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eRoHS and CE approval\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• No. of cores x cross section n x AWG\/MCM:\u003c\/strong\u003e 4 G 1 + (2 x 14)C\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Outer Ø inches\/mm ±10%:\u003c\/strong\u003e\u003cspan\u003e 1,504 - 38,2\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Nominal voltage:\u003c\/strong\u003e\u003cspan\u003e UL 1277 TC-ER-600 V, UL 2277 WTTC \/ Flexible Motor Supply-1000 V, IEC: Uo\/U 600\/1000 V\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Temperature range UL:\u003cspan\u003e  \u003c\/span\u003e\u003c\/strong\u003eup to 90°C Fixed laying: - 40 oC up to + 105 oC Flexible installation: - 5 oC up to + 105 oC\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Min. bending radius:\u003c\/strong\u003e\u003cspan\u003e Fixed laying: 6 x d Flexible application: 20 x d\u003cbr\u003e\u003cstrong\u003e• Copper weight Lbs\/Mft:\u003c\/strong\u003e 1493,9\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Cable weight approx. Lbs\/Mft:\u003c\/strong\u003e\u003cspan\u003e 1842,6\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e\u003cspan\u003e 33292F7004BA01\u003c\/span\u003e\u003c\/p\u003e","brand":"Elettrotek Kabel","offers":[{"title":"Default Title","offer_id":44266451206298,"sku":"33292F7004BA01","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/308_c16c011c-9422-47a3-95ea-460ca9c697c4.png?v=1759825859"},{"product_id":"2-0-4c-14-2c-bare-copper-shielded-al-tape-tc-braid-pvc-gaalflex-tray-vfd-1405-600v-cable","title":"2\/0-4C+14\/2C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/F2143-American-Industrial-Mining-Cables_removed_7.pdf?v=1703677301\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4\u003e\n\u003cstrong\u003e2\/0-4C+14\/2C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 2\/0-4C+14\/2C Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Gaalflex Bare Copper Shielded Al Tape TC Braid PVC Tray VFD 1405 600V Cable is a specialized cable designed for use in various industrial applications. It features a construction that includes bare copper conductors, shielding with aluminum tape and TC (Tinned Copper) braid, and a PVC jacket.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eGaalflex VFD 1405 600V Cable specifications\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eBare Copper Shielded Al Tape TC Braid PVC Tray Cable\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eInstrumentation cable standards\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eTray cable applications and usage\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eVFD cable for motor drives\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eShielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThis cable is shielded, which means it provides protection against electromagnetic interference (EMI) and radio-frequency interference (RFI). This shielding ensures stable and reliable signal transmission, critical for VFD systems.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eBare Copper Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe use of bare copper conductors ensures excellent electrical conductivity, reducing energy losses and allowing for efficient power transmission.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eAluminum Tape and TC Braid Shielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe combination of aluminum tape and tinned copper (TC) braid shielding provides enhanced protection against EMI and RFI, making it ideal for VFD applications where signal integrity is crucial.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003ePVC Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe PVC (Polyvinyl Chloride) jacket offers durability and resistance to environmental factors, making the cable suitable for both indoor and outdoor tray installations.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e600V Rating:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eWith a 600V rating, this cable can handle the voltage requirements of many VFD systems commonly used in industrial settings.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eNational Electrical Code (NEC):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor general electrical installation guidelines.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUL (Underwriters Laboratories):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eEnsuring safety and performance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIEEE Standards:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor specific applications like VFDs.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eLocal Electrical Codes:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eLocal regulations for compliance.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eConductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eflexible red copper conductor Cl. 5, acc. to IEC 60228, DIN VDE 0295 and UL standard 83\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eInsulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003efrom 18 AWG up to 16 AWG: GAALTHERM 520 from 14 AWG and over: GAALTHERM 591\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eCores color:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+3g..: 3 black conductors numbered + 3 green-yellow conductors divided in 3 inertstices 3x..+1g.. \/ 4g..+(2x..) or 4g..+(2x..+2x..): black cores with consecutive numbers acc. to EN 50334 + green\/yellow\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eStranding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+1g..: cores twisted together + fillers 3x..+3g..: phase units laid up with earth-conductors in interstices 4g..+(2x..) or 4g..+(2x..+2x..): control cores twisted in pair(s) and screened, supply cores and control screened pair(s) twisted together\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIndividual screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e4g..+(2x..) or 4g..+(2x..+2x..): aluminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOverall screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ealuminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOuter Sheath:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eblack (similar RAL 9005), GAALTHERM 520\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUV resistant\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eoutdoor use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003einstallation in hazardous areas\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 2277 WTTC or Flexible Motor Supply\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 1277 (Oil-resistant according to UL OIL RES I and Water-resistant, UL 90°C Dry or 90°C Wet )\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUL only for TC-ER use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request c(UL) type CIC\/TC FT4, AWM I\/II A\/B FT4\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request DIRECT BURIAL\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to to NFPA 79 2007 and NEC 336.10(7) Class 1, Div. 2 Art. 336, 392, 501\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for application acc. to EN 55011, DIN VDE 0875 and EN 61800-3\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for chain application, see technical data*\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eRoHS and CE approval\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• No. of cores x cross section n x AWG\/MCM:\u003c\/strong\u003e 4 G 2\/0 + (2 x 14)C\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Outer Ø inches\/mm ±10%:\u003c\/strong\u003e\u003cspan\u003e 1,72 - 43,7\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Nominal voltage:\u003c\/strong\u003e\u003cspan\u003e UL 1277 TC-ER-600 V, UL 2277 WTTC \/ Flexible Motor Supply-1000 V, IEC: Uo\/U 600\/1000 V\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Temperature range UL:\u003cspan\u003e  \u003c\/span\u003e\u003c\/strong\u003eup to 90°C Fixed laying: - 40 oC up to + 105 oC Flexible installation: - 5 oC up to + 105 oC\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Min. bending radius:\u003c\/strong\u003e\u003cspan\u003e Fixed laying: 6 x d Flexible application: 20 x d\u003cbr\u003e\u003cstrong\u003e• Copper weight Lbs\/Mft:\u003c\/strong\u003e 2036,8\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Cable weight approx. Lbs\/Mft:\u003c\/strong\u003e\u003cspan\u003e 2483\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e\u003cspan\u003e 33292F7004BA2C\u003c\/span\u003e\u003c\/p\u003e","brand":"Elettrotek Kabel","offers":[{"title":"Default Title","offer_id":44266494558362,"sku":"33292F7004BA2C","price":52.7,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/308_e9c53b58-3ee3-4fa0-9460-c6e55ef9586a.png?v=1762987986"},{"product_id":"14-4c-18-2c-18-2c-bare-copper-shielded-al-tape-tc-braid-pvc-gaalflex-tray-vfd-1405-600v-cable","title":"14\/4C+(18\/2C)+(18\/2C) Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/F2143-American-Industrial-Mining-Cables_removed_7.pdf?v=1703677301\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4\u003e\n\u003cstrong\u003e14\/4C+(18\/2C)+(18\/2C) Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 14\/4C+(18\/2C)+(18\/2C) Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Gaalflex Bare Copper Shielded Al Tape TC Braid PVC Tray VFD 1405 600V Cable is a specialized cable designed for use in various industrial applications. It features a construction that includes bare copper conductors, shielding with aluminum tape and TC (Tinned Copper) braid, and a PVC jacket.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eGaalflex VFD 1405 600V Cable specifications\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eBare Copper Shielded Al Tape TC Braid PVC Tray Cable\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eInstrumentation cable standards\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eTray cable applications and usage\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eVFD cable for motor drives\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eShielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThis cable is shielded, which means it provides protection against electromagnetic interference (EMI) and radio-frequency interference (RFI). This shielding ensures stable and reliable signal transmission, critical for VFD systems.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eBare Copper Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe use of bare copper conductors ensures excellent electrical conductivity, reducing energy losses and allowing for efficient power transmission.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eAluminum Tape and TC Braid Shielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe combination of aluminum tape and tinned copper (TC) braid shielding provides enhanced protection against EMI and RFI, making it ideal for VFD applications where signal integrity is crucial.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003ePVC Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe PVC (Polyvinyl Chloride) jacket offers durability and resistance to environmental factors, making the cable suitable for both indoor and outdoor tray installations.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e600V Rating:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eWith a 600V rating, this cable can handle the voltage requirements of many VFD systems commonly used in industrial settings.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eNational Electrical Code (NEC):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor general electrical installation guidelines.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUL (Underwriters Laboratories):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eEnsuring safety and performance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIEEE Standards:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor specific applications like VFDs.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eLocal Electrical Codes:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eLocal regulations for compliance.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eConductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eflexible red copper conductor Cl. 5, acc. to IEC 60228, DIN VDE 0295 and UL standard 83\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eInsulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003efrom 18 AWG up to 16 AWG: GAALTHERM 520 from 14 AWG and over: GAALTHERM 591\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eCores color:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+3g..: 3 black conductors numbered + 3 green-yellow conductors divided in 3 inertstices 3x..+1g.. \/ 4g..+(2x..) or 4g..+(2x..+2x..): black cores with consecutive numbers acc. to EN 50334 + green\/yellow\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eStranding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+1g..: cores twisted together + fillers 3x..+3g..: phase units laid up with earth-conductors in interstices 4g..+(2x..) or 4g..+(2x..+2x..): control cores twisted in pair(s) and screened, supply cores and control screened pair(s) twisted together\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIndividual screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e4g..+(2x..) or 4g..+(2x..+2x..): aluminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOverall screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ealuminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOuter Sheath:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eblack (similar RAL 9005), GAALTHERM 520\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUV resistant\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eoutdoor use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003einstallation in hazardous areas\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 2277 WTTC or Flexible Motor Supply\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 1277 (Oil-resistant according to UL OIL RES I and Water-resistant, UL 90°C Dry or 90°C Wet )\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUL only for TC-ER use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request c(UL) type CIC\/TC FT4, AWM I\/II A\/B FT4\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request DIRECT BURIAL\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to to NFPA 79 2007 and NEC 336.10(7) Class 1, Div. 2 Art. 336, 392, 501\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for application acc. to EN 55011, DIN VDE 0875 and EN 61800-3\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for chain application, see technical data*\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eRoHS and CE approval\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• No. of cores x cross section n x AWG\/MCM:\u003c\/strong\u003e 4 G 14 + (2 x 18)C + (2 x 18)C\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Outer Ø inches\/mm ±10%:\u003c\/strong\u003e\u003cspan\u003e 0,692 - 17,3\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Nominal voltage:\u003c\/strong\u003e\u003cspan\u003e UL 1277 TC-ER-600 V, UL 2277 WTTC \/ Flexible Motor Supply-1000 V, IEC: Uo\/U 600\/1000 V\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Temperature range UL:\u003cspan\u003e  \u003c\/span\u003e\u003c\/strong\u003eup to 90°C Fixed laying: - 40 oC up to + 105 oC Flexible installation: - 5 oC up to + 105 oC\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Min. bending radius:\u003c\/strong\u003e\u003cspan\u003e Fixed laying: 6 x d Flexible application: 20 x d\u003cbr\u003e\u003cstrong\u003e• Copper weight Lbs\/Mft:\u003c\/strong\u003e 173,4\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Cable weight approx. Lbs\/Mft:\u003c\/strong\u003e\u003cspan\u003e 287,6\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e\u003cspan\u003e 33290F7004B900\u003c\/span\u003e\u003c\/p\u003e","brand":"Elettrotek Kabel","offers":[{"title":"Default Title","offer_id":44266570809498,"sku":"33290F7004B900","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/308_878022e9-593b-4048-b1e6-cc3d00438d96.png?v=1759825861"},{"product_id":"12-4c-18-2c-18-2c-bare-copper-shielded-al-tape-tc-braid-pvc-gaalflex-tray-vfd-1405-600v-cable","title":"12\/4C+(18\/2C)+(18\/2C) Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/F2143-American-Industrial-Mining-Cables_removed_7.pdf?v=1703677301\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4\u003e\n\u003cstrong\u003e12\/4C+(18\/2C)+(18\/2C) Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 12\/4C+(18\/2C)+(18\/2C) Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Gaalflex Bare Copper Shielded Al Tape TC Braid PVC Tray VFD 1405 600V Cable is a specialized cable designed for use in various industrial applications. It features a construction that includes bare copper conductors, shielding with aluminum tape and TC (Tinned Copper) braid, and a PVC jacket.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eGaalflex VFD 1405 600V Cable specifications\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eBare Copper Shielded Al Tape TC Braid PVC Tray Cable\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eInstrumentation cable standards\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eTray cable applications and usage\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eVFD cable for motor drives\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eShielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThis cable is shielded, which means it provides protection against electromagnetic interference (EMI) and radio-frequency interference (RFI). This shielding ensures stable and reliable signal transmission, critical for VFD systems.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eBare Copper Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe use of bare copper conductors ensures excellent electrical conductivity, reducing energy losses and allowing for efficient power transmission.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eAluminum Tape and TC Braid Shielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe combination of aluminum tape and tinned copper (TC) braid shielding provides enhanced protection against EMI and RFI, making it ideal for VFD applications where signal integrity is crucial.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003ePVC Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe PVC (Polyvinyl Chloride) jacket offers durability and resistance to environmental factors, making the cable suitable for both indoor and outdoor tray installations.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e600V Rating:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eWith a 600V rating, this cable can handle the voltage requirements of many VFD systems commonly used in industrial settings.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eNational Electrical Code (NEC):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor general electrical installation guidelines.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUL (Underwriters Laboratories):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eEnsuring safety and performance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIEEE Standards:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor specific applications like VFDs.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eLocal Electrical Codes:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eLocal regulations for compliance.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eConductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eflexible red copper conductor Cl. 5, acc. to IEC 60228, DIN VDE 0295 and UL standard 83\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eInsulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003efrom 18 AWG up to 16 AWG: GAALTHERM 520 from 14 AWG and over: GAALTHERM 591\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eCores color:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+3g..: 3 black conductors numbered + 3 green-yellow conductors divided in 3 inertstices 3x..+1g.. \/ 4g..+(2x..) or 4g..+(2x..+2x..): black cores with consecutive numbers acc. to EN 50334 + green\/yellow\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eStranding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+1g..: cores twisted together + fillers 3x..+3g..: phase units laid up with earth-conductors in interstices 4g..+(2x..) or 4g..+(2x..+2x..): control cores twisted in pair(s) and screened, supply cores and control screened pair(s) twisted together\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIndividual screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e4g..+(2x..) or 4g..+(2x..+2x..): aluminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOverall screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ealuminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOuter Sheath:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eblack (similar RAL 9005), GAALTHERM 520\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUV resistant\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eoutdoor use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003einstallation in hazardous areas\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 2277 WTTC or Flexible Motor Supply\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 1277 (Oil-resistant according to UL OIL RES I and Water-resistant, UL 90°C Dry or 90°C Wet )\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUL only for TC-ER use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request c(UL) type CIC\/TC FT4, AWM I\/II A\/B FT4\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request DIRECT BURIAL\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to to NFPA 79 2007 and NEC 336.10(7) Class 1, Div. 2 Art. 336, 392, 501\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for application acc. to EN 55011, DIN VDE 0875 and EN 61800-3\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for chain application, see technical data*\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eRoHS and CE approval\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• No. of cores x cross section n x AWG\/MCM:\u003c\/strong\u003e 4 G 12 + (2 x 18)C + (2 x 18)C\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Outer Ø inches\/mm ±10%:\u003c\/strong\u003e\u003cspan\u003e 0,74 - 18,5\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Nominal voltage:\u003c\/strong\u003e\u003cspan\u003e UL 1277 TC-ER-600 V, UL 2277 WTTC \/ Flexible Motor Supply-1000 V, IEC: Uo\/U 600\/1000 V\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Temperature range UL:\u003cspan\u003e  \u003c\/span\u003e\u003c\/strong\u003eup to 90°C Fixed laying: - 40 oC up to + 105 oC Flexible installation: - 5 oC up to + 105 oC\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Min. bending radius:\u003c\/strong\u003e\u003cspan\u003e Fixed laying: 6 x d Flexible application: 20 x d\u003cbr\u003e\u003cstrong\u003e• Copper weight Lbs\/Mft:\u003c\/strong\u003e 216,4\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Cable weight approx. Lbs\/Mft:\u003c\/strong\u003e\u003cspan\u003e 346,1\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e\u003cspan\u003e 33290F7004B901\u003c\/span\u003e\u003c\/p\u003e","brand":"Elettrotek Kabel","offers":[{"title":"Default Title","offer_id":44266637361306,"sku":"33290F7004B901","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/308_09b3fa5b-a751-4401-9442-d456b6be9326.png?v=1762988000"},{"product_id":"12-4c-18-2c-16-2c-bare-copper-shielded-al-tape-tc-braid-pvc-gaalflex-tray-vfd-1405-600v-cable","title":"12\/4C+(18\/2C)+(16\/2C) Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/F2143-American-Industrial-Mining-Cables_removed_7.pdf?v=1703677301\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4\u003e\n\u003cstrong\u003e12\/4C+(18\/2C)+(16\/2C) Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 12\/4C+(18\/2C)+(16\/2C) Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Gaalflex Bare Copper Shielded Al Tape TC Braid PVC Tray VFD 1405 600V Cable is a specialized cable designed for use in various industrial applications. It features a construction that includes bare copper conductors, shielding with aluminum tape and TC (Tinned Copper) braid, and a PVC jacket.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eGaalflex VFD 1405 600V Cable specifications\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eBare Copper Shielded Al Tape TC Braid PVC Tray Cable\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eInstrumentation cable standards\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eTray cable applications and usage\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eVFD cable for motor drives\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eShielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThis cable is shielded, which means it provides protection against electromagnetic interference (EMI) and radio-frequency interference (RFI). This shielding ensures stable and reliable signal transmission, critical for VFD systems.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eBare Copper Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe use of bare copper conductors ensures excellent electrical conductivity, reducing energy losses and allowing for efficient power transmission.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eAluminum Tape and TC Braid Shielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe combination of aluminum tape and tinned copper (TC) braid shielding provides enhanced protection against EMI and RFI, making it ideal for VFD applications where signal integrity is crucial.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003ePVC Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe PVC (Polyvinyl Chloride) jacket offers durability and resistance to environmental factors, making the cable suitable for both indoor and outdoor tray installations.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e600V Rating:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eWith a 600V rating, this cable can handle the voltage requirements of many VFD systems commonly used in industrial settings.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eNational Electrical Code (NEC):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor general electrical installation guidelines.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUL (Underwriters Laboratories):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eEnsuring safety and performance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIEEE Standards:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor specific applications like VFDs.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eLocal Electrical Codes:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eLocal regulations for compliance.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eConductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eflexible red copper conductor Cl. 5, acc. to IEC 60228, DIN VDE 0295 and UL standard 83\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eInsulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003efrom 18 AWG up to 16 AWG: GAALTHERM 520 from 14 AWG and over: GAALTHERM 591\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eCores color:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+3g..: 3 black conductors numbered + 3 green-yellow conductors divided in 3 inertstices 3x..+1g.. \/ 4g..+(2x..) or 4g..+(2x..+2x..): black cores with consecutive numbers acc. to EN 50334 + green\/yellow\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eStranding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+1g..: cores twisted together + fillers 3x..+3g..: phase units laid up with earth-conductors in interstices 4g..+(2x..) or 4g..+(2x..+2x..): control cores twisted in pair(s) and screened, supply cores and control screened pair(s) twisted together\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIndividual screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e4g..+(2x..) or 4g..+(2x..+2x..): aluminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOverall screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ealuminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOuter Sheath:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eblack (similar RAL 9005), GAALTHERM 520\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUV resistant\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eoutdoor use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003einstallation in hazardous areas\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 2277 WTTC or Flexible Motor Supply\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 1277 (Oil-resistant according to UL OIL RES I and Water-resistant, UL 90°C Dry or 90°C Wet )\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUL only for TC-ER use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request c(UL) type CIC\/TC FT4, AWM I\/II A\/B FT4\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request DIRECT BURIAL\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to to NFPA 79 2007 and NEC 336.10(7) Class 1, Div. 2 Art. 336, 392, 501\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for application acc. to EN 55011, DIN VDE 0875 and EN 61800-3\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for chain application, see technical data*\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eRoHS and CE approval\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• No. of cores x cross section n x AWG\/MCM:\u003c\/strong\u003e 4 G 12 + (2 x 18)C + (2 x 16)C\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Outer Ø inches\/mm ±10%:\u003c\/strong\u003e\u003cspan\u003e 0,76 - 19\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Nominal voltage:\u003c\/strong\u003e\u003cspan\u003e UL 1277 TC-ER-600 V, UL 2277 WTTC \/ Flexible Motor Supply-1000 V, IEC: Uo\/U 600\/1000 V\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Temperature range UL:\u003cspan\u003e  \u003c\/span\u003e\u003c\/strong\u003eup to 90°C Fixed laying: - 40 oC up to + 105 oC Flexible installation: - 5 oC up to + 105 oC\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Min. bending radius:\u003c\/strong\u003e\u003cspan\u003e Fixed laying: 6 x d Flexible application: 20 x d\u003cbr\u003e\u003cstrong\u003e• Copper weight Lbs\/Mft:\u003c\/strong\u003e 224,4\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Cable weight approx. Lbs\/Mft:\u003c\/strong\u003e\u003cspan\u003e 358,2\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e\u003cspan\u003e 33290F7004B902\u003c\/span\u003e\u003c\/p\u003e","brand":"Elettrotek Kabel","offers":[{"title":"Default Title","offer_id":44266642210970,"sku":"33290F7004B902","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/308_8b066aab-4bd1-4151-a0ee-f09be308f55a.png?v=1762988006"},{"product_id":"10-4c-18-2c-16-2c-bare-copper-shielded-al-tape-tc-braid-pvc-gaalflex-tray-vfd-1405-600v-cable","title":"10\/4C+(18\/2C)+(16\/2C) Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/F2143-American-Industrial-Mining-Cables_removed_7.pdf?v=1703677301\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4\u003e\n\u003cstrong\u003e10\/4C+(18\/2C)+(16\/2C) Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 10\/4C+(18\/2C)+(16\/2C) Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Gaalflex Bare Copper Shielded Al Tape TC Braid PVC Tray VFD 1405 600V Cable is a specialized cable designed for use in various industrial applications. It features a construction that includes bare copper conductors, shielding with aluminum tape and TC (Tinned Copper) braid, and a PVC jacket.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eGaalflex VFD 1405 600V Cable specifications\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eBare Copper Shielded Al Tape TC Braid PVC Tray Cable\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eInstrumentation cable standards\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eTray cable applications and usage\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eVFD cable for motor drives\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eShielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThis cable is shielded, which means it provides protection against electromagnetic interference (EMI) and radio-frequency interference (RFI). This shielding ensures stable and reliable signal transmission, critical for VFD systems.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eBare Copper Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe use of bare copper conductors ensures excellent electrical conductivity, reducing energy losses and allowing for efficient power transmission.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eAluminum Tape and TC Braid Shielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe combination of aluminum tape and tinned copper (TC) braid shielding provides enhanced protection against EMI and RFI, making it ideal for VFD applications where signal integrity is crucial.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003ePVC Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe PVC (Polyvinyl Chloride) jacket offers durability and resistance to environmental factors, making the cable suitable for both indoor and outdoor tray installations.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e600V Rating:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eWith a 600V rating, this cable can handle the voltage requirements of many VFD systems commonly used in industrial settings.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eNational Electrical Code (NEC):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor general electrical installation guidelines.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUL (Underwriters Laboratories):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eEnsuring safety and performance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIEEE Standards:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor specific applications like VFDs.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eLocal Electrical Codes:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eLocal regulations for compliance.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eConductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eflexible red copper conductor Cl. 5, acc. to IEC 60228, DIN VDE 0295 and UL standard 83\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eInsulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003efrom 18 AWG up to 16 AWG: GAALTHERM 520 from 14 AWG and over: GAALTHERM 591\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eCores color:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+3g..: 3 black conductors numbered + 3 green-yellow conductors divided in 3 inertstices 3x..+1g.. \/ 4g..+(2x..) or 4g..+(2x..+2x..): black cores with consecutive numbers acc. to EN 50334 + green\/yellow\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eStranding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+1g..: cores twisted together + fillers 3x..+3g..: phase units laid up with earth-conductors in interstices 4g..+(2x..) or 4g..+(2x..+2x..): control cores twisted in pair(s) and screened, supply cores and control screened pair(s) twisted together\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIndividual screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e4g..+(2x..) or 4g..+(2x..+2x..): aluminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOverall screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ealuminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOuter Sheath:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eblack (similar RAL 9005), GAALTHERM 520\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUV resistant\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eoutdoor use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003einstallation in hazardous areas\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 2277 WTTC or Flexible Motor Supply\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 1277 (Oil-resistant according to UL OIL RES I and Water-resistant, UL 90°C Dry or 90°C Wet )\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUL only for TC-ER use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request c(UL) type CIC\/TC FT4, AWM I\/II A\/B FT4\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request DIRECT BURIAL\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to to NFPA 79 2007 and NEC 336.10(7) Class 1, Div. 2 Art. 336, 392, 501\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for application acc. to EN 55011, DIN VDE 0875 and EN 61800-3\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for chain application, see technical data*\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eRoHS and CE approval\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• No. of cores x cross section n x AWG\/MCM:\u003c\/strong\u003e 4 G 10 + (2 x 18)C + (2 x 16)C\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Outer Ø inches\/mm ±10%:\u003c\/strong\u003e\u003cspan\u003e 0,8 - 20\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Nominal voltage:\u003c\/strong\u003e\u003cspan\u003e UL 1277 TC-ER-600 V, UL 2277 WTTC \/ Flexible Motor Supply-1000 V, IEC: Uo\/U 600\/1000 V\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Temperature range UL:\u003cspan\u003e  \u003c\/span\u003e\u003c\/strong\u003eup to 90°C Fixed laying: - 40 oC up to + 105 oC Flexible installation: - 5 oC up to + 105 oC\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Min. bending radius:\u003c\/strong\u003e\u003cspan\u003e Fixed laying: 6 x d Flexible application: 20 x d\u003cbr\u003e\u003cstrong\u003e• Copper weight Lbs\/Mft:\u003c\/strong\u003e 283,6\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Cable weight approx. Lbs\/Mft:\u003c\/strong\u003e\u003cspan\u003e 424,7\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e\u003cspan\u003e 33290F7004B903\u003c\/span\u003e\u003c\/p\u003e","brand":"Elettrotek Kabel","offers":[{"title":"Default Title","offer_id":44266651517082,"sku":"33290F7004B903","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/308_129314d6-6f1d-4a5b-9909-a7a60424a00f.png?v=1762988013"},{"product_id":"8-4c-18-2c-16-2c-bare-copper-shielded-al-tape-tc-braid-pvc-gaalflex-tray-vfd-1405-600v-cable","title":"8\/4C+(18\/2C)+(16\/2C) Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/F2143-American-Industrial-Mining-Cables_removed_7.pdf?v=1703677301\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4\u003e\n\u003cstrong\u003e8\/4C+(18\/2C)+(16\/2C) Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 8\/4C+(18\/2C)+(16\/2C) Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Gaalflex Bare Copper Shielded Al Tape TC Braid PVC Tray VFD 1405 600V Cable is a specialized cable designed for use in various industrial applications. It features a construction that includes bare copper conductors, shielding with aluminum tape and TC (Tinned Copper) braid, and a PVC jacket.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eGaalflex VFD 1405 600V Cable specifications\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eBare Copper Shielded Al Tape TC Braid PVC Tray Cable\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eInstrumentation cable standards\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eTray cable applications and usage\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eVFD cable for motor drives\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eShielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThis cable is shielded, which means it provides protection against electromagnetic interference (EMI) and radio-frequency interference (RFI). This shielding ensures stable and reliable signal transmission, critical for VFD systems.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eBare Copper Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe use of bare copper conductors ensures excellent electrical conductivity, reducing energy losses and allowing for efficient power transmission.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eAluminum Tape and TC Braid Shielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe combination of aluminum tape and tinned copper (TC) braid shielding provides enhanced protection against EMI and RFI, making it ideal for VFD applications where signal integrity is crucial.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003ePVC Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe PVC (Polyvinyl Chloride) jacket offers durability and resistance to environmental factors, making the cable suitable for both indoor and outdoor tray installations.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e600V Rating:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eWith a 600V rating, this cable can handle the voltage requirements of many VFD systems commonly used in industrial settings.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eNational Electrical Code (NEC):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor general electrical installation guidelines.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUL (Underwriters Laboratories):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eEnsuring safety and performance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIEEE Standards:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor specific applications like VFDs.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eLocal Electrical Codes:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eLocal regulations for compliance.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eConductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eflexible red copper conductor Cl. 5, acc. to IEC 60228, DIN VDE 0295 and UL standard 83\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eInsulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003efrom 18 AWG up to 16 AWG: GAALTHERM 520 from 14 AWG and over: GAALTHERM 591\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eCores color:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+3g..: 3 black conductors numbered + 3 green-yellow conductors divided in 3 inertstices 3x..+1g.. \/ 4g..+(2x..) or 4g..+(2x..+2x..): black cores with consecutive numbers acc. to EN 50334 + green\/yellow\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eStranding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+1g..: cores twisted together + fillers 3x..+3g..: phase units laid up with earth-conductors in interstices 4g..+(2x..) or 4g..+(2x..+2x..): control cores twisted in pair(s) and screened, supply cores and control screened pair(s) twisted together\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIndividual screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e4g..+(2x..) or 4g..+(2x..+2x..): aluminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOverall screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ealuminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOuter Sheath:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eblack (similar RAL 9005), GAALTHERM 520\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUV resistant\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eoutdoor use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003einstallation in hazardous areas\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 2277 WTTC or Flexible Motor Supply\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 1277 (Oil-resistant according to UL OIL RES I and Water-resistant, UL 90°C Dry or 90°C Wet )\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUL only for TC-ER use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request c(UL) type CIC\/TC FT4, AWM I\/II A\/B FT4\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request DIRECT BURIAL\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to to NFPA 79 2007 and NEC 336.10(7) Class 1, Div. 2 Art. 336, 392, 501\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for application acc. to EN 55011, DIN VDE 0875 and EN 61800-3\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for chain application, see technical data*\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eRoHS and CE approval\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• No. of cores x cross section n x AWG\/MCM:\u003c\/strong\u003e 4 G 8 + (2 x 18)C + (2 x 16)C\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Outer Ø inches\/mm ±10%:\u003c\/strong\u003e\u003cspan\u003e 0,98 - 24,4\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Nominal voltage:\u003c\/strong\u003e\u003cspan\u003e UL 1277 TC-ER-600 V, UL 2277 WTTC \/ Flexible Motor Supply-1000 V, IEC: Uo\/U 600\/1000 V\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Temperature range UL:\u003cspan\u003e  \u003c\/span\u003e\u003c\/strong\u003eup to 90°C Fixed laying: - 40 oC up to + 105 oC Flexible installation: - 5 oC up to + 105 oC\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Min. bending radius:\u003c\/strong\u003e\u003cspan\u003e Fixed laying: 6 x d Flexible application: 20 x d\u003cbr\u003e\u003cstrong\u003e• Copper weight Lbs\/Mft:\u003c\/strong\u003e 401,2\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Cable weight approx. Lbs\/Mft:\u003c\/strong\u003e\u003cspan\u003e 633\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e\u003cspan\u003e 33290F7004B904\u003c\/span\u003e\u003c\/p\u003e","brand":"Elettrotek Kabel","offers":[{"title":"Default Title","offer_id":44266655875226,"sku":"33290F7004B904","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/308_f23c3229-d5de-43b4-9ecc-ac8f9b16b8f7.png?v=1762988014"},{"product_id":"6-4c-16-2c-16-2c-bare-copper-shielded-al-tape-tc-braid-pvc-gaalflex-tray-vfd-1405-600v-cable","title":"6\/4C+(16\/2C)+(16\/2C) Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/F2143-American-Industrial-Mining-Cables_removed_7.pdf?v=1703677301\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4\u003e\n\u003cstrong\u003e6\/4C+(16\/2C)+(16\/2C) Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 6\/4C+(16\/2C)+(16\/2C) Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Gaalflex Bare Copper Shielded Al Tape TC Braid PVC Tray VFD 1405 600V Cable is a specialized cable designed for use in various industrial applications. It features a construction that includes bare copper conductors, shielding with aluminum tape and TC (Tinned Copper) braid, and a PVC jacket.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eGaalflex VFD 1405 600V Cable specifications\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eBare Copper Shielded Al Tape TC Braid PVC Tray Cable\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eInstrumentation cable standards\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eTray cable applications and usage\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eVFD cable for motor drives\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eShielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThis cable is shielded, which means it provides protection against electromagnetic interference (EMI) and radio-frequency interference (RFI). This shielding ensures stable and reliable signal transmission, critical for VFD systems.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eBare Copper Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe use of bare copper conductors ensures excellent electrical conductivity, reducing energy losses and allowing for efficient power transmission.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eAluminum Tape and TC Braid Shielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe combination of aluminum tape and tinned copper (TC) braid shielding provides enhanced protection against EMI and RFI, making it ideal for VFD applications where signal integrity is crucial.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003ePVC Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe PVC (Polyvinyl Chloride) jacket offers durability and resistance to environmental factors, making the cable suitable for both indoor and outdoor tray installations.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e600V Rating:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eWith a 600V rating, this cable can handle the voltage requirements of many VFD systems commonly used in industrial settings.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eNational Electrical Code (NEC):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor general electrical installation guidelines.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUL (Underwriters Laboratories):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eEnsuring safety and performance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIEEE Standards:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor specific applications like VFDs.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eLocal Electrical Codes:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eLocal regulations for compliance.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eConductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eflexible red copper conductor Cl. 5, acc. to IEC 60228, DIN VDE 0295 and UL standard 83\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eInsulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003efrom 18 AWG up to 16 AWG: GAALTHERM 520 from 14 AWG and over: GAALTHERM 591\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eCores color:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+3g..: 3 black conductors numbered + 3 green-yellow conductors divided in 3 inertstices 3x..+1g.. \/ 4g..+(2x..) or 4g..+(2x..+2x..): black cores with consecutive numbers acc. to EN 50334 + green\/yellow\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eStranding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+1g..: cores twisted together + fillers 3x..+3g..: phase units laid up with earth-conductors in interstices 4g..+(2x..) or 4g..+(2x..+2x..): control cores twisted in pair(s) and screened, supply cores and control screened pair(s) twisted together\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIndividual screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e4g..+(2x..) or 4g..+(2x..+2x..): aluminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOverall screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ealuminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOuter Sheath:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eblack (similar RAL 9005), GAALTHERM 520\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUV resistant\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eoutdoor use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003einstallation in hazardous areas\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 2277 WTTC or Flexible Motor Supply\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 1277 (Oil-resistant according to UL OIL RES I and Water-resistant, UL 90°C Dry or 90°C Wet )\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUL only for TC-ER use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request c(UL) type CIC\/TC FT4, AWM I\/II A\/B FT4\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request DIRECT BURIAL\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to to NFPA 79 2007 and NEC 336.10(7) Class 1, Div. 2 Art. 336, 392, 501\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for application acc. to EN 55011, DIN VDE 0875 and EN 61800-3\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for chain application, see technical data*\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eRoHS and CE approval\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• No. of cores x cross section n x AWG\/MCM:\u003c\/strong\u003e 4 G 6 + (2 x 16)C + (2 x 16)C\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Outer Ø inches\/mm ±10%:\u003c\/strong\u003e\u003cspan\u003e 1,08 - 27\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Nominal voltage:\u003c\/strong\u003e\u003cspan\u003e UL 1277 TC-ER-600 V, UL 2277 WTTC \/ Flexible Motor Supply-1000 V, IEC: Uo\/U 600\/1000 V\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Temperature range UL:\u003cspan\u003e  \u003c\/span\u003e\u003c\/strong\u003eup to 90°C Fixed laying: - 40 oC up to + 105 oC Flexible installation: - 5 oC up to + 105 oC\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Min. bending radius:\u003c\/strong\u003e\u003cspan\u003e Fixed laying: 6 x d Flexible application: 20 x d\u003cbr\u003e\u003cstrong\u003e• Copper weight Lbs\/Mft:\u003c\/strong\u003e 571,9\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Cable weight approx. Lbs\/Mft:\u003c\/strong\u003e\u003cspan\u003e 826,6\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e\u003cspan\u003e 33290F7004B905\u003c\/span\u003e\u003c\/p\u003e","brand":"Elettrotek Kabel","offers":[{"title":"Default Title","offer_id":44266660659354,"sku":"33290F7004B905","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/308_758a02c6-d8b8-47e7-ad5e-5b56fd329fb4.png?v=1762988017"},{"product_id":"12-4c-14-2c-14-2c-bare-copper-shielded-al-tape-tc-braid-pvc-gaalflex-tray-vfd-1405-600v-cable","title":"12\/4C+(14\/2C)+(14\/2C) Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/F2143-American-Industrial-Mining-Cables_removed_7.pdf?v=1703677301\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4\u003e\n\u003cstrong\u003e12\/4C+(14\/2C)+(14\/2C) Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 12\/4C+(14\/2C)+(14\/2C) Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Gaalflex Bare Copper Shielded Al Tape TC Braid PVC Tray VFD 1405 600V Cable is a specialized cable designed for use in various industrial applications. It features a construction that includes bare copper conductors, shielding with aluminum tape and TC (Tinned Copper) braid, and a PVC jacket.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eGaalflex VFD 1405 600V Cable specifications\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eBare Copper Shielded Al Tape TC Braid PVC Tray Cable\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eInstrumentation cable standards\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eTray cable applications and usage\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eVFD cable for motor drives\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eShielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThis cable is shielded, which means it provides protection against electromagnetic interference (EMI) and radio-frequency interference (RFI). This shielding ensures stable and reliable signal transmission, critical for VFD systems.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eBare Copper Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe use of bare copper conductors ensures excellent electrical conductivity, reducing energy losses and allowing for efficient power transmission.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eAluminum Tape and TC Braid Shielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe combination of aluminum tape and tinned copper (TC) braid shielding provides enhanced protection against EMI and RFI, making it ideal for VFD applications where signal integrity is crucial.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003ePVC Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe PVC (Polyvinyl Chloride) jacket offers durability and resistance to environmental factors, making the cable suitable for both indoor and outdoor tray installations.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e600V Rating:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eWith a 600V rating, this cable can handle the voltage requirements of many VFD systems commonly used in industrial settings.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eNational Electrical Code (NEC):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor general electrical installation guidelines.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUL (Underwriters Laboratories):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eEnsuring safety and performance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIEEE Standards:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor specific applications like VFDs.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eLocal Electrical Codes:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eLocal regulations for compliance.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eConductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eflexible red copper conductor Cl. 5, acc. to IEC 60228, DIN VDE 0295 and UL standard 83\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eInsulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003efrom 18 AWG up to 16 AWG: GAALTHERM 520 from 14 AWG and over: GAALTHERM 591\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eCores color:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+3g..: 3 black conductors numbered + 3 green-yellow conductors divided in 3 inertstices 3x..+1g.. \/ 4g..+(2x..) or 4g..+(2x..+2x..): black cores with consecutive numbers acc. to EN 50334 + green\/yellow\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eStranding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+1g..: cores twisted together + fillers 3x..+3g..: phase units laid up with earth-conductors in interstices 4g..+(2x..) or 4g..+(2x..+2x..): control cores twisted in pair(s) and screened, supply cores and control screened pair(s) twisted together\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIndividual screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e4g..+(2x..) or 4g..+(2x..+2x..): aluminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOverall screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ealuminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOuter Sheath:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eblack (similar RAL 9005), GAALTHERM 520\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUV resistant\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eoutdoor use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003einstallation in hazardous areas\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 2277 WTTC or Flexible Motor Supply\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 1277 (Oil-resistant according to UL OIL RES I and Water-resistant, UL 90°C Dry or 90°C Wet )\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUL only for TC-ER use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request c(UL) type CIC\/TC FT4, AWM I\/II A\/B FT4\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request DIRECT BURIAL\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to to NFPA 79 2007 and NEC 336.10(7) Class 1, Div. 2 Art. 336, 392, 501\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for application acc. to EN 55011, DIN VDE 0875 and EN 61800-3\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for chain application, see technical data*\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eRoHS and CE approval\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• No. of cores x cross section n x AWG\/MCM:\u003c\/strong\u003e 4 G 12 + (2 x 14)C + (2 x 14)C\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Outer Ø inches\/mm ±10%:\u003c\/strong\u003e\u003cspan\u003e 0,78 - 19,8\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Nominal voltage:\u003c\/strong\u003e\u003cspan\u003e UL 1277 TC-ER-600 V, UL 2277 WTTC \/ Flexible Motor Supply-1000 V, IEC: Uo\/U 600\/1000 V\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Temperature range UL:\u003cspan\u003e  \u003c\/span\u003e\u003c\/strong\u003eup to 90°C Fixed laying: - 40 oC up to + 105 oC Flexible installation: - 5 oC up to + 105 oC\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Min. bending radius:\u003c\/strong\u003e\u003cspan\u003e Fixed laying: 6 x d Flexible application: 20 x d\u003cbr\u003e\u003cstrong\u003e• Copper weight Lbs\/Mft:\u003c\/strong\u003e 266,1\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Cable weight approx. Lbs\/Mft:\u003c\/strong\u003e\u003cspan\u003e 396,5\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e\u003cspan\u003e 33290F7004B906\u003c\/span\u003e\u003c\/p\u003e","brand":"Elettrotek Kabel","offers":[{"title":"Default Title","offer_id":44266672193690,"sku":"33290F7004B906","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/308_d6591d68-7760-4d50-8c23-99ad91c5273b.png?v=1759825863"},{"product_id":"10-4c-14-2c-14-2c-bare-copper-shielded-al-tape-tc-braid-pvc-gaalflex-tray-vfd-1405-600v-cable","title":"10\/4C+(14\/2C)+(14\/2C) Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/F2143-American-Industrial-Mining-Cables_removed_7.pdf?v=1703677301\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch4\u003e\n\u003cstrong\u003e10\/4C+(14\/2C)+(14\/2C) Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eAllowable Ampacity\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003efor 10\/4C+(14\/2C)+(14\/2C) Bare Copper Shielded Al Tape TC Braid PVC Gaalflex Tray VFD 1405 600V Cable\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\"\u003e:\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e100 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbout:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Gaalflex Bare Copper Shielded Al Tape TC Braid PVC Tray VFD 1405 600V Cable is a specialized cable designed for use in various industrial applications. It features a construction that includes bare copper conductors, shielding with aluminum tape and TC (Tinned Copper) braid, and a PVC jacket.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eAlso K\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003enown As:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eGaalflex VFD 1405 600V Cable specifications\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eBare Copper Shielded Al Tape TC Braid PVC Tray Cable\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eInstrumentation cable standards\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eTray cable applications and usage\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eVFD cable for motor drives\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eShielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThis cable is shielded, which means it provides protection against electromagnetic interference (EMI) and radio-frequency interference (RFI). This shielding ensures stable and reliable signal transmission, critical for VFD systems.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eBare Copper Conductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe use of bare copper conductors ensures excellent electrical conductivity, reducing energy losses and allowing for efficient power transmission.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eAluminum Tape and TC Braid Shielding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe combination of aluminum tape and tinned copper (TC) braid shielding provides enhanced protection against EMI and RFI, making it ideal for VFD applications where signal integrity is crucial.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003ePVC Jacket:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThe PVC (Polyvinyl Chloride) jacket offers durability and resistance to environmental factors, making the cable suitable for both indoor and outdoor tray installations.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e600V Rating:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eWith a 600V rating, this cable can handle the voltage requirements of many VFD systems commonly used in industrial settings.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandards:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eNational Electrical Code (NEC):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor general electrical installation guidelines.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUL (Underwriters Laboratories):\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eEnsuring safety and performance.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIEEE Standards:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eFor specific applications like VFDs.\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eLocal Electrical Codes:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eLocal regulations for compliance.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConstruction:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eConductor:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eflexible red copper conductor Cl. 5, acc. to IEC 60228, DIN VDE 0295 and UL standard 83\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eInsulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003efrom 18 AWG up to 16 AWG: GAALTHERM 520 from 14 AWG and over: GAALTHERM 591\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eCores color:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+3g..: 3 black conductors numbered + 3 green-yellow conductors divided in 3 inertstices 3x..+1g.. \/ 4g..+(2x..) or 4g..+(2x..+2x..): black cores with consecutive numbers acc. to EN 50334 + green\/yellow\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eStranding:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e3x..+1g..: cores twisted together + fillers 3x..+3g..: phase units laid up with earth-conductors in interstices 4g..+(2x..) or 4g..+(2x..+2x..): control cores twisted in pair(s) and screened, supply cores and control screened pair(s) twisted together\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eIndividual screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e4g..+(2x..) or 4g..+(2x..+2x..): aluminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOverall screen:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003ealuminium tape + PETP foil and tinned copper braid 85% coverage +\/- 5%\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOuter Sheath:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eblack (similar RAL 9005), GAALTHERM 520\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUV resistant\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eoutdoor use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003einstallation in hazardous areas\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 2277 WTTC or Flexible Motor Supply\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to UL 1277 (Oil-resistant according to UL OIL RES I and Water-resistant, UL 90°C Dry or 90°C Wet )\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eUL only for TC-ER use\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request c(UL) type CIC\/TC FT4, AWM I\/II A\/B FT4\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eon request DIRECT BURIAL\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eacc. to to NFPA 79 2007 and NEC 336.10(7) Class 1, Div. 2 Art. 336, 392, 501\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for application acc. to EN 55011, DIN VDE 0875 and EN 61800-3\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003esuitable for chain application, see technical data*\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eRoHS and CE approval\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• No. of cores x cross section n x AWG\/MCM:\u003c\/strong\u003e 4 G 10 + (2 x 14)C + (2 x 14)C\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Outer Ø inches\/mm ±10%:\u003c\/strong\u003e\u003cspan\u003e 0,87 - 22,1\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Nominal voltage:\u003c\/strong\u003e\u003cspan\u003e UL 1277 TC-ER-600 V, UL 2277 WTTC \/ Flexible Motor Supply-1000 V, IEC: Uo\/U 600\/1000 V\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Temperature range UL:\u003cspan\u003e  \u003c\/span\u003e\u003c\/strong\u003eup to 90°C Fixed laying: - 40 oC up to + 105 oC Flexible installation: - 5 oC up to + 105 oC\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Min. bending radius:\u003c\/strong\u003e\u003cspan\u003e Fixed laying: 6 x d Flexible application: 20 x d\u003cbr\u003e\u003cstrong\u003e• Copper weight Lbs\/Mft:\u003c\/strong\u003e 317,9\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e• Cable weight approx. Lbs\/Mft:\u003c\/strong\u003e\u003cspan\u003e 494,6\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003e• Part Number:\u003c\/strong\u003e\u003cspan\u003e 33290F7004B907\u003c\/span\u003e\u003c\/p\u003e","brand":"Elettrotek Kabel","offers":[{"title":"Default Title","offer_id":44266678943898,"sku":"33290F7004B907","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/308_673f1ed2-b3f2-41c0-b156-72cbbecb5c7e.png?v=1762988024"}],"url":"https:\/\/nassaunationalcable.com\/collections\/gaalflex-bare-copper-shielded-al-tape-tc-braid-pvc-tray-vfd-1405-600v-cable.oembed?page=5","provider":"NassauNationalCable","version":"1.0","type":"link"}