{"title":"ELCI \u0026 EGFPD Ground Fault Protection Devices","description":"","products":[{"product_id":"120v-60a-10ma-hd-pro-single-phase-inline-elci-24520001-1","title":"120V 60A 10mA HD PRO Single Phase Inline ELCI 24520001-1","description":"\u003cp\u003e\u003cstrong\u003eAbout :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShockshield panel mounts provide protection for personnel and equipment when leakage levels have a potentially lethal ground current.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso known as :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e60A HD ELCI, 60A Heavy Duty ELCI, 120V ELCI, 120V HD PRO ELCI,  120V Heavy Duty ELCI.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e• Amperage : \u003c\/strong\u003e60A\u003cbr\u003e\u003cstrong\u003e• Voltage :\u003c\/strong\u003e 120V\u003cbr\u003e\u003cstrong\u003e• Phase :\u003c\/strong\u003e Single\u003cbr\u003e\u003cstrong\u003e• Trip Point :\u003c\/strong\u003e 10mA\u003cbr\u003e\u003cstrong\u003e• Cord Gauge :\u003c\/strong\u003e 4\/3 AWG\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e \u003cstrong\u003eUPC\u003c\/strong\u003e \u003cstrong\u003e:\u003c\/strong\u003e 024098901674\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e \u003cstrong\u003ePart Number\u003c\/strong\u003e \u003cstrong\u003e: \u003c\/strong\u003e24520001-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\" data-mce-style=\"font-size: 0.875rem;\"\u003eFeatures :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e Trip point up to 50mA\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e 25mS trip response time (typically)\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e Manual Reset\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e Engineered to trip within 25 miliseconds\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e Applications: Plant maintenance, equipment service\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e","brand":"Southwire","offers":[{"title":"Default Title","offer_id":44597762949274,"sku":"24520001-1","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/2_a38d9b1a-9cb5-43a1-a143-b8fc7291544f.png?v=1762994124"},{"product_id":"380v-60a-10ma-hd-pro-three-phase-inline-elci-25560001-1","title":"380V 60A 10mA HD PRO Three Phase Inline ELCI 25560001-1","description":"\u003cp\u003e\u003cstrong\u003eAbout :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShockshield panel mounts provide protection for personnel and equipment when leakage levels have a potentially lethal ground current.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso known as :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e60A HD ELCI, 60A Heavy Duty ELCI, 380V ELCI, 380V HD PRO ELCI,  380V Heavy Duty ELCI.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e• Amperage : \u003c\/strong\u003e60A\u003cbr\u003e\u003cstrong\u003e• Voltage :\u003c\/strong\u003e 380V\u003cbr\u003e\u003cstrong\u003e• Phase :\u003c\/strong\u003e Three\u003cbr\u003e\u003cstrong\u003e• Trip Point :\u003c\/strong\u003e 10mA\u003cbr\u003e\u003cstrong\u003e• Cord Gauge :\u003c\/strong\u003e 4\/4 AWG\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e \u003cstrong\u003eUPC\u003c\/strong\u003e \u003cstrong\u003e:\u003c\/strong\u003e 024098902398\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e \u003cstrong\u003ePart Number\u003c\/strong\u003e \u003cstrong\u003e: \u003c\/strong\u003e25560001-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\" data-mce-style=\"font-size: 0.875rem;\"\u003eFeatures :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e Applications Include: Motors, Manufacturing Equipment, Pumping Systems, Welders, Pressure Washers, Hoists\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e Response Time for Ground Fault: 25mS - Typically\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e Drop Out Voltage: 60% Rated Voltage - Typically\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e Connection Type: 2 ft Flying Leads\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e Endurance: 3,000 Operations Minimum\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e Overload Current: Six Times Rated Current\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e Insulation Voltage: 1500 Vrms - 1 Min.\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e Cord Gauge: 4\/4 AWG\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e Power On Indication: Lighted Indicator\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e","brand":"Southwire","offers":[{"title":"Default Title","offer_id":44597777105050,"sku":"25560001-1","price":1197.36,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/2_42b94e50-c579-40c0-af03-61d8702829d7.png?v=1762994130"},{"product_id":"480v-100a-hd-pro-three-phase-inline-elci-24736001-1","title":"480V 100A HD PRO Three Phase Inline ELCI 24736001-1","description":"\u003cp\u003e\u003cstrong\u003eAbout :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShockshield panel mounts provide protection for personnel and equipment when leakage levels have a potentially lethal ground current.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso known as :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e100A HD ELCI, 100A Heavy Duty ELCI, 480V ELCI, 480V HD PRO ELCI,  480V Heavy Duty ELCI.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e• Amperage : \u003c\/strong\u003e100A\u003cbr\u003e\u003cstrong\u003e• Voltage :\u003c\/strong\u003e 380V\u003cbr\u003e\u003cstrong\u003e• Phase :\u003c\/strong\u003e Three\u003cbr\u003e\u003cstrong\u003e• Trip Point :\u003c\/strong\u003e upto 50mA\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e \u003cstrong\u003eUPC\u003c\/strong\u003e \u003cstrong\u003e:\u003c\/strong\u003e 029892140199\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e \u003cstrong\u003ePart Number\u003c\/strong\u003e \u003cstrong\u003e: \u003c\/strong\u003e24736001-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\" data-mce-style=\"font-size: 0.875rem;\"\u003eFeatures :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e Trip point up to 50mA\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e 25mS trip response time (typically)\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e Manual Reset\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e Engineered to trip within 25 miliseconds\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e Applications: Plant maintenance, equipment service\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e","brand":"Southwire","offers":[{"title":"Default Title","offer_id":44597815902362,"sku":"24736001-1","price":2999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/2_4d3475cc-2254-4b9f-bf3a-030b5db6b4b0.png?v=1762994144"},{"product_id":"208-240v-80a-heavy-duty-pro-three-phase-elci-gfci-24786001-1","title":"208\/240V 80A Heavy Duty Pro Three Phase ELCI\/GFCI 24786001-1","description":"\u003cp\u003e\u003cstrong\u003eAbout :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShockshield panel mounts provide protection for personnel and equipment when leakage levels have a potentially lethal ground current.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso known as :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e80A HD ELCI, 80A Heavy Duty ELCI, 240V ELCI, 208V HD PRO ELCI,  480V Heavy Duty ELCI\/GFCI.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e• Amperage : 8\u003c\/strong\u003e0A\u003cbr\u003e\u003cstrong\u003e• Voltage :\u003c\/strong\u003e 208\/240V\u003cbr\u003e\u003cstrong\u003e• Phase :\u003c\/strong\u003e Three\u003cbr\u003e\u003cstrong\u003e• Trip Point :\u003c\/strong\u003e upto 50mA\u003cbr\u003e\u003cstrong\u003e• Dimensions :\u003c\/strong\u003e 7\" H x 9\" W x 20\" D\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e \u003cstrong\u003eUPC\u003c\/strong\u003e \u003cstrong\u003e:\u003c\/strong\u003e 024098901902\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e \u003cstrong\u003ePart Number\u003c\/strong\u003e \u003cstrong\u003e: \u003c\/strong\u003e24786001-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eFeatures :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e Trip point up to 50mA\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e 25mS trip response time (typically)\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e Manual Reset\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e Engineered to trip within 25 miliseconds\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e Applications: Plant maintenance, equipment service\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e","brand":"Southwire","offers":[{"title":"Default Title","offer_id":44603563507866,"sku":"24786001-1","price":1698.66,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_71a8d480-8c10-4574-b25d-5f404e21c85b.png?v=1762994256"},{"product_id":"480v-80a-heavy-duty-pro-three-phase-elci-gfci-24796001-1","title":"480V 80A Heavy Duty Pro Three Phase ELCI\/GFCI 24796001-1","description":"\u003cp\u003e\u003cstrong\u003eAbout :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShockshield panel mounts provide protection for personnel and equipment when leakage levels have a potentially lethal ground current.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso known as :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e80A HD ELCI, 80A Heavy Duty ELCI, 480V ELCI, 480V HD PRO ELCI\/GFCI,  480V Heavy Duty ELCI\/GFCI.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e• Amperage : \u003c\/strong\u003e80A\u003cbr\u003e\u003cstrong\u003e• Voltage :\u003c\/strong\u003e 480V\u003cbr\u003e\u003cstrong\u003e• Phase :\u003c\/strong\u003e Three\u003cbr\u003e\u003cstrong\u003e• Trip Point :\u003c\/strong\u003e upto 50mA\u003cbr\u003e\u003cstrong\u003e• Dimensions :\u003c\/strong\u003e 7\" H x 9\" W x 20\" D\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e \u003cstrong\u003eUPC\u003c\/strong\u003e \u003cstrong\u003e:\u003c\/strong\u003e 024098901940\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e \u003cstrong\u003ePart Number\u003c\/strong\u003e \u003cstrong\u003e: \u003c\/strong\u003e24796001-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\" data-mce-style=\"font-size: 0.875rem;\"\u003eFeatures :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e Trip point up to 50mA\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e 25mS trip response time (typically)\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e Manual Reset\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e Engineered to trip within 25 miliseconds\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e Applications: Plant maintenance, equipment service\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e","brand":"Southwire","offers":[{"title":"Default Title","offer_id":44603570356378,"sku":"24796001-1","price":2659.43,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_c958a6f8-3bf9-46e3-8500-3c587e8e7949.png?v=1762994258"},{"product_id":"480v-60a-heavy-duty-pro-single-phase-elci-gfci-24672001-1","title":"480V 60A Heavy Duty Pro Single Phase ELCI\/GFCI 24672001-1","description":"\u003cp\u003e\u003cstrong\u003eAbout :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShockshield panel mounts provide protection for personnel and equipment when leakage levels have a potentially lethal ground current.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso known as :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e60A HD ELCI, 60A Heavy Duty ELCI, 480V ELCI, 480V HD PRO ELCI\/GFCI,  480V Heavy Duty ELCI\/GFCI, Single Phase GFCI.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e• Amperage : \u003c\/strong\u003e60A\u003cbr\u003e\u003cstrong\u003e• Voltage :\u003c\/strong\u003e 480V\u003cbr\u003e\u003cstrong\u003e• Phase :\u003c\/strong\u003e Single\u003cbr\u003e\u003cstrong\u003e• Trip Point :\u003c\/strong\u003e upto 50mA\u003cbr\u003e\u003cstrong\u003e• Dimensions :\u003c\/strong\u003e 7\" H x 10\" W x 16\" D\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e \u003cstrong\u003eUPC\u003c\/strong\u003e \u003cstrong\u003e:\u003c\/strong\u003e 024098901933\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e \u003cstrong\u003ePart Number\u003c\/strong\u003e \u003cstrong\u003e: \u003c\/strong\u003e24672001-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eFeatures :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e Trip point up to 50mA\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e 25mS trip response time (typically)\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e Manual Reset\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e Engineered to trip within 25 miliseconds\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e Applications: Plant maintenance, equipment service\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e","brand":"Southwire","offers":[{"title":"Default Title","offer_id":44603574288538,"sku":"24672001-1","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_5ac9baf6-0611-43cd-b3cc-866061643555.png?v=1762994263"},{"product_id":"208-240v-60a-heavy-duty-pro-three-phase-elci-gfci-24542001-1","title":"208\/240V 60A Heavy Duty Pro Three Phase ELCI\/GFCI 24542001-1","description":"\u003cp\u003e[pdf]\u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/High_Power_GFCI_and_ELCI.pdf?v=1753082663\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\" style=\"font-size: 0.875rem; width: 71.2406%; height: 294.034px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"text-align: center; width: 42.5343%; height: 19.6023px;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 57.1914%; height: 19.6023px;\"\u003eHigh Power GFCI and ELCI \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"text-align: center; width: 42.5343%; height: 19.6023px;\"\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 57.1914%; height: 19.6023px;\"\u003e208\/240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"text-align: center; width: 42.5343%; height: 19.6023px;\"\u003e\u003cstrong\u003eAmperage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 57.1914%; height: 19.6023px;\"\u003e60A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"text-align: center; width: 42.5343%; height: 19.6023px;\"\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 57.1914%; height: 19.6023px;\"\u003eThree\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"text-align: center; width: 42.5343%; height: 19.6023px;\"\u003e\u003cstrong\u003eCord Gauge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 57.1914%; height: 19.6023px;\"\u003e4\/4 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"text-align: center; width: 42.5343%; height: 19.6023px;\"\u003e\u003cstrong\u003eEnclosure Color\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 57.1914%; height: 19.6023px;\"\u003eGrey\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"text-align: center; width: 42.5343%; height: 19.6023px;\"\u003e\u003cstrong\u003eEndurance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 57.1914%; height: 19.6023px;\"\u003e3,000 Operations Minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"text-align: center; width: 42.5343%; height: 19.6023px;\"\u003e\u003cstrong\u003eOverload Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 57.1914%; height: 19.6023px;\"\u003eSix Times Rated Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"text-align: center; width: 42.5343%; height: 19.6023px;\"\u003e\u003cstrong\u003eInsulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 57.1914%; height: 19.6023px;\"\u003e1500 Vrms - 1 Min.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"text-align: center; width: 42.5343%; height: 19.6023px;\"\u003e\u003cstrong\u003eDrop Out Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 57.1914%; height: 19.6023px;\"\u003e60% Rated Voltage—Typically\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"text-align: center; width: 42.5343%; height: 19.6023px;\"\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 57.1914%; height: 19.6023px;\"\u003e2 ft Flying Leads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"text-align: center; width: 42.5343%; height: 19.6023px;\"\u003e\u003cstrong\u003eEnclosure \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 57.1914%; height: 19.6023px;\"\u003eNEMA 4 Polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"text-align: center; width: 42.5343%; height: 19.6023px;\"\u003e\u003cstrong\u003ePower On Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 57.1914%; height: 19.6023px;\"\u003eLighted Indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"text-align: center; width: 42.5343%; height: 19.6023px;\"\u003e\u003cstrong\u003eUPC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 57.1914%; height: 19.6023px;\"\u003e024098901896\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"text-align: center; width: 42.5343%; height: 19.6023px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 57.1914%; height: 19.6023px;\"\u003e24542001-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003e208\/240V 60A Heavy Duty Pro Three Phase ELCI\/GFCI\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHD Pro provides protection for personnel and equipment. Shockshield panel mounts provide protection for personnel and equipment when leakage levels have a potentially lethal ground current.\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e Trip point up to mA\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e 25 ms trip response time (typically)\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Manual Reset\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Engineered to trip within 25 milliseconds\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Applications: Plant maintenance, equipment service\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Southwire","offers":[{"title":"Default Title","offer_id":44603586674842,"sku":"24542001-1","price":1504.67,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_e8242f24-5407-4fbe-a34b-69d2c0f17f08.png?v=1762994269"},{"product_id":"208-240v-30a-heavy-duty-pro-three-phase-elci-gfci-24846001-1","title":"208\/240V 30A Heavy Duty Pro Three Phase ELCI\/GFCI 24846001-1","description":"\u003cp\u003e\u003cstrong\u003eAbout :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShockshield panel mounts provide protection for personnel and equipment when leakage levels have a potentially lethal ground current.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso known as :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e30A HD ELCI, 30A Heavy Duty ELCI, 208V ELCI, 208\/240V HD PRO ELCI\/GFCI, 240V Heavy Duty ELCI\/GFCI.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e• Amperage : \u003c\/strong\u003e30A\u003cbr\u003e\u003cstrong\u003e• Voltage :\u003c\/strong\u003e 208\/240V\u003cbr\u003e\u003cstrong\u003e• Phase :\u003c\/strong\u003e Three\u003cbr\u003e\u003cstrong\u003e• Trip Point :\u003c\/strong\u003e upto 50mA\u003cbr\u003e\u003cstrong\u003e• Dimensions :\u003c\/strong\u003e 7\" H x 7\" W x 16\" D\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e \u003cstrong\u003eUPC\u003c\/strong\u003e \u003cstrong\u003e:\u003c\/strong\u003e 024098902428\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e \u003cstrong\u003ePart Number\u003c\/strong\u003e \u003cstrong\u003e: \u003c\/strong\u003e24846001-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eFeatures :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e Trip point up to 50mA\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e 25mS trip response time (typically)\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e Manual Reset\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e Engineered to trip within 25 miliseconds\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e Applications: Plant maintenance, equipment service\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e","brand":"Southwire","offers":[{"title":"Default Title","offer_id":44603594899610,"sku":"24846001-1","price":1091.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_f78afd7e-f2b1-4369-89dc-5b0f43003c80.png?v=1762994277"},{"product_id":"480v-30a-heavy-duty-pro-three-phase-elci-gfci-24646001-1","title":"480V 30A Heavy Duty Pro Three Phase ELCI\/GFCI 24646001-1","description":"\u003cp\u003e\u003cstrong\u003eAbout :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShockshield panel mounts provide protection for personnel and equipment when leakage levels have a potentially lethal ground current.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso known as :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e30A HD ELCI, 30A Heavy Duty ELCI, 480V ELCI, 480V HD PRO ELCI\/GFCI, 480V Heavy Duty ELCI\/GFCI.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e• Amperage : \u003c\/strong\u003e30A\u003cbr\u003e\u003cstrong\u003e• Voltage :\u003c\/strong\u003e 480V\u003cbr\u003e\u003cstrong\u003e• Phase :\u003c\/strong\u003e Three\u003cbr\u003e\u003cstrong\u003e• Trip Point :\u003c\/strong\u003e upto 50mA\u003cbr\u003e\u003cstrong\u003e• Dimensions :\u003c\/strong\u003e 7\" H x 10\" W x 16\" D\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e \u003cstrong\u003eUPC\u003c\/strong\u003e \u003cstrong\u003e:\u003c\/strong\u003e 024098901919\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e \u003cstrong\u003ePart Number\u003c\/strong\u003e \u003cstrong\u003e: \u003c\/strong\u003e24646001-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eFeatures :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e Trip point up to 50mA\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e 25mS trip response time (typically)\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e Manual Reset\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e Engineered to trip within 25 miliseconds\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e•\u003c\/strong\u003e Applications: Plant maintenance, equipment service\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e","brand":"Southwire","offers":[{"title":"Default Title","offer_id":44603611938970,"sku":"24646001-1","price":1270.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_f869fd19-7f24-46e6-a179-46c35dd3241c.png?v=1762994287"},{"product_id":"208-240v-30a-three-phase-egfpd-ground-fault-protection-with-10-30-50ma-trip-settings","title":"208\/240V 30A Three-Phase EGFPD Ground Fault Protection with 10\/30\/50mA Trip Settings","description":"\u003cp\u003e[pdf]\u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PDF_f8f0387d-28cf-44e8-ac96-295dc059f29f.pdf?v=1777971684\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\" style=\"width: 40.6957%; height: 480.688px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003eVolts\/Amps\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 39.1875px;\"\u003e 208-240V\/30A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003eTripLevel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 39.1875px;\"\u003e10, 30 \u0026amp; 50mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 39.1875px;\"\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 55.1875px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eResponsetime \u003c\/strong\u003e\u003cstrong\u003eforgroundfault\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 55.1875px;\"\u003e25mS-typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 35.5938px;\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eEndurance\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 35.5938px;\"\u003e3,000operationsminimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 55.1875px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eOverload\u003cbr\u003eCurrent\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 55.1875px;\"\u003esixtimesratedcurrent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 55.1875px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eOperating\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003etemperaturerange\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 55.1875px;\"\u003e-20˚Cto+40˚C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 35.5938px;\"\u003e1500VRMS-1Min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 55.1875px;\"\u003e\n\u003cp\u003e\u003cstrong\u003ePower On indication\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 55.1875px;\"\u003elightedindicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eDropoutvoltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 35.5938px;\"\u003e60%ratedvoltage-typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eReset type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center;\"\u003eauto\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eConnection type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center;\"\u003euserattachable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eEnclosure\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center;\"\u003eNEMA 416guagesteel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe EGFPD (Equipment Ground Fault Protection Device) is a safety device used to protect electrical systems from ground faults by detecting any unintentional contact between an electrical system and the ground. It is designed to prevent the damage that can occur from these faults, which could lead to fires or electrical hazards.\u003c\/p\u003e\n\u003ch4\u003eFeatures :\u003c\/h4\u003e\n\u003cp\u003e• Ground Fault Detection – Monitors current to detect unwanted leakage to ground.\u003c\/p\u003e\n\u003cp\u003e• Adjustable Trip Settings – Allows setting different fault current thresholds (e.g., 6 mA, 10 mA, 30 mA).\u003c\/p\u003e\n\u003cp\u003e• Fast Response Time – Trips quickly to minimize damage when a ground fault occurs.\u003c\/p\u003e\n\u003cp\u003e• Manual \/ Automatic Reset – Can be reset manually or automatically after a trip (varies by model).\u003c\/p\u003e\n\u003cp\u003e• Indicator\/Alarm – Visual or audible indication when a fault is detected\/tripped.\u003c\/p\u003e\n\u003cp\u003e• Suitable for Industrial Use – Designed to protect equipment in commercial\/industrial applications (not just residential).\u003c\/p\u003e\n\u003cp\u003e• Overcurrent Protection – Some models include basic overcurrent interruption along with ground fault protection.\u003c\/p\u003e\n\u003cp\u003e• Compact \u0026amp; Durable Construction – Built for rugged electrical environments.\u003c\/p\u003e","brand":"NNC","offers":[{"title":"Default Title","offer_id":63557435785585,"sku":"44110-012","price":1746.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/84_417f45f5-5d14-497f-bea7-75236dc9b7c2.png?v=1777969871"},{"product_id":"480v-30a-three-phase-egfpd-ground-fault-protection-with-10-30-50ma-trip-settings","title":"480V 30A Three-Phase EGFPD Ground Fault Protection with 10\/30\/50mA Trip Settings","description":"\u003cp\u003e[pdf]\u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PDF_f8f0387d-28cf-44e8-ac96-295dc059f29f.pdf?v=1777971684\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 40.6957%; height: 480.688px;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003eVolts\/Amps\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 39.1875px;\"\u003e 480V\/30A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003eTripLevel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 39.1875px;\"\u003e10, 30 \u0026amp; 50mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 39.1875px;\"\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 55.1875px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eResponsetime \u003c\/strong\u003e\u003cstrong\u003eforgroundfault\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 55.1875px;\"\u003e25mS-typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 35.5938px;\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eEndurance\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 35.5938px;\"\u003e3,000operationsminimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 55.1875px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eOverload\u003cbr\u003eCurrent\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 55.1875px;\"\u003esixtimesratedcurrent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 55.1875px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eOperating\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003etemperaturerange\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 55.1875px;\"\u003e-20˚Cto+40˚C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 35.5938px;\"\u003e1500VRMS-1Min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 55.1875px;\"\u003e\n\u003cp\u003e\u003cstrong\u003ePower On indication\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 55.1875px;\"\u003elightedindicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eDropoutvoltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 35.5938px;\"\u003e60%ratedvoltage-typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eReset type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center;\"\u003eauto\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eConnection type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center;\"\u003euserattachable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eEnclosure\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center;\"\u003eNEMA 416guagesteel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe EGFPD (Equipment Ground Fault Protection Device) is a safety device used to protect electrical systems from ground faults by detecting any unintentional contact between an electrical system and the ground. It is designed to prevent the damage that can occur from these faults, which could lead to fires or electrical hazards.\u003c\/p\u003e\n\u003ch4\u003eFeatures :\u003c\/h4\u003e\n\u003cp\u003e• Ground Fault Detection – Monitors current to detect unwanted leakage to ground.\u003c\/p\u003e\n\u003cp\u003e• Adjustable Trip Settings – Allows setting different fault current thresholds (e.g., 6 mA, 10 mA, 30 mA).\u003c\/p\u003e\n\u003cp\u003e• Fast Response Time – Trips quickly to minimize damage when a ground fault occurs.\u003c\/p\u003e\n\u003cp\u003e• Manual \/ Automatic Reset – Can be reset manually or automatically after a trip (varies by model).\u003c\/p\u003e\n\u003cp\u003e• Indicator\/Alarm – Visual or audible indication when a fault is detected\/tripped.\u003c\/p\u003e\n\u003cp\u003e• Suitable for Industrial Use – Designed to protect equipment in commercial\/industrial applications (not just residential).\u003c\/p\u003e\n\u003cp\u003e• Overcurrent Protection – Some models include basic overcurrent interruption along with ground fault protection.\u003c\/p\u003e\n\u003cp\u003e• Compact \u0026amp; Durable Construction – Built for rugged electrical environments.\u003c\/p\u003e","brand":"NNC","offers":[{"title":"Default Title","offer_id":63558845596017,"sku":"44120-012","price":1866.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/84_417f45f5-5d14-497f-bea7-75236dc9b7c2.png?v=1777969871"},{"product_id":"208-240v-60a-three-phase-egfpd-ground-fault-protection-with-10-30-50ma-trip-settings","title":"208\/240V 60A Three-Phase EGFPD Ground Fault Protection with 10\/30\/50mA Trip Settings","description":"\u003cp\u003e[pdf]\u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PDF_f8f0387d-28cf-44e8-ac96-295dc059f29f.pdf?v=1777971684\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\" style=\"width: 40.6957%; height: 480.688px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003eVolts\/Amps\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 39.1875px;\"\u003e 208-240V\/60A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003eTripLevel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 39.1875px;\"\u003e10, 30 \u0026amp; 50mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 39.1875px;\"\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 55.1875px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eResponsetime \u003c\/strong\u003e\u003cstrong\u003eforgroundfault\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 55.1875px;\"\u003e25mS-typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 35.5938px;\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eEndurance\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 35.5938px;\"\u003e3,000operationsminimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 55.1875px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eOverload\u003cbr\u003eCurrent\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 55.1875px;\"\u003esixtimesratedcurrent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 55.1875px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eOperating\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003etemperaturerange\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 55.1875px;\"\u003e-20˚Cto+40˚C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 35.5938px;\"\u003e1500VRMS-1Min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 55.1875px;\"\u003e\n\u003cp\u003e\u003cstrong\u003ePower On indication\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 55.1875px;\"\u003elightedindicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eDropoutvoltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 35.5938px;\"\u003e60%ratedvoltage-typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eReset type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center;\"\u003eauto\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eConnection type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center;\"\u003euserattachable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eEnclosure\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center;\"\u003eNEMA 416guagesteel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe EGFPD (Equipment Ground Fault Protection Device) is a safety device used to protect electrical systems from ground faults by detecting any unintentional contact between an electrical system and the ground. It is designed to prevent the damage that can occur from these faults, which could lead to fires or electrical hazards.\u003c\/p\u003e\n\u003ch4\u003eFeatures :\u003c\/h4\u003e\n\u003cp\u003e• Ground Fault Detection – Monitors current to detect unwanted leakage to ground.\u003c\/p\u003e\n\u003cp\u003e• Adjustable Trip Settings – Allows setting different fault current thresholds (e.g., 6 mA, 10 mA, 30 mA).\u003c\/p\u003e\n\u003cp\u003e• Fast Response Time – Trips quickly to minimize damage when a ground fault occurs.\u003c\/p\u003e\n\u003cp\u003e• Manual \/ Automatic Reset – Can be reset manually or automatically after a trip (varies by model).\u003c\/p\u003e\n\u003cp\u003e• Indicator\/Alarm – Visual or audible indication when a fault is detected\/tripped.\u003c\/p\u003e\n\u003cp\u003e• Suitable for Industrial Use – Designed to protect equipment in commercial\/industrial applications (not just residential).\u003c\/p\u003e\n\u003cp\u003e• Overcurrent Protection – Some models include basic overcurrent interruption along with ground fault protection.\u003c\/p\u003e\n\u003cp\u003e• Compact \u0026amp; Durable Construction – Built for rugged electrical environments.\u003c\/p\u003e","brand":"NNC","offers":[{"title":"Default Title","offer_id":63558875087217,"sku":"44140-012","price":1464.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/84_d714a013-e2a4-4b69-b23c-fdd615eb7686.png?v=1777991836"},{"product_id":"480v-60a-three-phase-egfpd-ground-fault-protection-with-10-30-50ma-trip-settings","title":"480V 60A Three-Phase EGFPD Ground Fault Protection with 10\/30\/50mA Trip Settings","description":"\u003cp\u003e[pdf]\u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PDF_f8f0387d-28cf-44e8-ac96-295dc059f29f.pdf?v=1777971684\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 40.6957%; height: 480.688px;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003eVolts\/Amps\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 39.1875px;\"\u003e 480V\/60A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003eTripLevel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 39.1875px;\"\u003e10, 30 \u0026amp; 50mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 39.1875px;\"\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 55.1875px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eResponsetime \u003c\/strong\u003e\u003cstrong\u003eforgroundfault\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 55.1875px;\"\u003e25mS-typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 35.5938px;\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eEndurance\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 35.5938px;\"\u003e3,000operationsminimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 55.1875px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eOverload\u003cbr\u003eCurrent\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 55.1875px;\"\u003esixtimesratedcurrent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 55.1875px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eOperating\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003etemperaturerange\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 55.1875px;\"\u003e-20˚Cto+40˚C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 35.5938px;\"\u003e1500VRMS-1Min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 55.1875px;\"\u003e\n\u003cp\u003e\u003cstrong\u003ePower On indication\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 55.1875px;\"\u003elightedindicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eDropoutvoltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 35.5938px;\"\u003e60%ratedvoltage-typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eReset type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center;\"\u003eauto\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eConnection type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center;\"\u003euserattachable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eEnclosure\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center;\"\u003eNEMA 416guagesteel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe EGFPD (Equipment Ground Fault Protection Device) is a safety device used to protect electrical systems from ground faults by detecting any unintentional contact between an electrical system and the ground. It is designed to prevent the damage that can occur from these faults, which could lead to fires or electrical hazards.\u003c\/p\u003e\n\u003ch4\u003eFeatures :\u003c\/h4\u003e\n\u003cp\u003e• Ground Fault Detection – Monitors current to detect unwanted leakage to ground.\u003c\/p\u003e\n\u003cp\u003e• Adjustable Trip Settings – Allows setting different fault current thresholds (e.g., 6 mA, 10 mA, 30 mA).\u003c\/p\u003e\n\u003cp\u003e• Fast Response Time – Trips quickly to minimize damage when a ground fault occurs.\u003c\/p\u003e\n\u003cp\u003e• Manual \/ Automatic Reset – Can be reset manually or automatically after a trip (varies by model).\u003c\/p\u003e\n\u003cp\u003e• Indicator\/Alarm – Visual or audible indication when a fault is detected\/tripped.\u003c\/p\u003e\n\u003cp\u003e• Suitable for Industrial Use – Designed to protect equipment in commercial\/industrial applications (not just residential).\u003c\/p\u003e\n\u003cp\u003e• Overcurrent Protection – Some models include basic overcurrent interruption along with ground fault protection.\u003c\/p\u003e\n\u003cp\u003e• Compact \u0026amp; Durable Construction – Built for rugged electrical environments.\u003c\/p\u003e","brand":"NNC","offers":[{"title":"Default Title","offer_id":63558906839409,"sku":"44130-012","price":2124.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/84_d714a013-e2a4-4b69-b23c-fdd615eb7686.png?v=1777991836"},{"product_id":"208-240v-30a-three-phase-elci-ground-fault-protection-with-10-30-50ma-trip-settings","title":"208\/240V 30A Three-Phase ELCI Ground Fault Protection with 10\/30\/50mA Trip Settings","description":"\u003cp\u003e[pdf]\u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PDF_f8f0387d-28cf-44e8-ac96-295dc059f29f.pdf?v=1777971684\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 40.6957%; height: 480.688px;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003eVolts\/Amps\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 39.1875px;\"\u003e 208-240V\/30A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003eTripLevel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 39.1875px;\"\u003e10, 30 \u0026amp; 50mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 39.1875px;\"\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 55.1875px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eResponsetime \u003c\/strong\u003e\u003cstrong\u003eforgroundfault\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 55.1875px;\"\u003e25mS-typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 35.5938px;\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eEndurance\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 35.5938px;\"\u003e3,000operationsminimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 55.1875px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eOverload\u003cbr\u003eCurrent\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 55.1875px;\"\u003esixtimesratedcurrent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 55.1875px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eOperating\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003etemperaturerange\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 55.1875px;\"\u003e-20˚Cto+40˚C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 35.5938px;\"\u003e1500VRMS-1Min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 55.1875px;\"\u003e\n\u003cp\u003e\u003cstrong\u003ePower On indication\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 55.1875px;\"\u003elightedindicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eDropoutvoltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 35.5938px;\"\u003e60%ratedvoltage-typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eReset type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center;\"\u003eauto\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eConnection type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center;\"\u003euserattachable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eEnclosure\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center;\"\u003eNEMA 416guagesteel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe ELCI provides advanced ground fault protection for electrical systems by detecting leakage currents that may pose a risk of electric shock or fire hazards. It is designed to interrupt the power supply when it detects an imbalance between the hot and neutral conductors, ensuring safety in both residential and industrial applications.\u003c\/p\u003e\n\u003ch4\u003eFeatures :\u003c\/h4\u003e\n\u003cp\u003e• Ground Fault Detection: Quickly detects any leakage currents that could lead to electric shock or fire hazards.\u003c\/p\u003e\n\u003cp\u003e• Adjustable Trip Settings: Allows for customizable trip levels (typically 10mA, 30mA, and 50mA) to match the specific protection requirements.\u003c\/p\u003e\n\u003cp\u003e• Three-Phase Protection: Ideal for three-phase electrical systems, providing protection for commercial and industrial applications.\u003c\/p\u003e\n\u003cp\u003e• Voltage Compatibility: Supports 208\/240V systems for widespread use in residential, commercial, and industrial settings.\u003c\/p\u003e\n\u003cp\u003e• Current Rating: Typically rated at 30A, suitable for medium-sized circuits.\u003c\/p\u003e\n\u003cp\u003e• High Sensitivity: Ensures rapid detection of ground faults, minimizing the risk of electrical shock.\u003c\/p\u003e\n\u003cp\u003e• Reliable and Durable: Built with quality components for long-term performance and safety.\u003c\/p\u003e\n\u003cp\u003e• Enhanced Safety: Provides reliable circuit interruption in the event of ground faults, enhancing overall electrical system safety.\u003c\/p\u003e","brand":"NNC","offers":[{"title":"Default Title","offer_id":63559174881649,"sku":"44610-001","price":1512.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/84_d714a013-e2a4-4b69-b23c-fdd615eb7686.png?v=1777991836"},{"product_id":"480v-30a-three-phase-elci-ground-fault-protection-with-10ma-30ma-and-50ma-trip-settings","title":"480V 30A Three-Phase ELCI Ground Fault Protection with 10mA, 30mA, and 50mA Trip Settings","description":"\u003cp\u003e[pdf]\u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PDF_f8f0387d-28cf-44e8-ac96-295dc059f29f.pdf?v=1777971684\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\" style=\"width: 40.6957%; height: 480.688px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003eVolts\/Amps\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 39.1875px;\"\u003e480V\/30A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003eTripLevel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 39.1875px;\"\u003e10, 30 \u0026amp; 50mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 39.1875px;\"\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 55.1875px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eResponsetime \u003c\/strong\u003e\u003cstrong\u003eforgroundfault\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 55.1875px;\"\u003e25mS-typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 35.5938px;\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eEndurance\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 35.5938px;\"\u003e3,000operationsminimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 55.1875px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eOverload\u003cbr\u003eCurrent\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 55.1875px;\"\u003esixtimesratedcurrent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 55.1875px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eOperating\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003etemperaturerange\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 55.1875px;\"\u003e-20˚Cto+40˚C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 35.5938px;\"\u003e1500VRMS-1Min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 55.1875px;\"\u003e\n\u003cp\u003e\u003cstrong\u003ePower On indication\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 55.1875px;\"\u003elightedindicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eDropoutvoltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 35.5938px;\"\u003e60%ratedvoltage-typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eReset type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center;\"\u003eauto\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eConnection type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center;\"\u003euserattachable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eEnclosure\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center;\"\u003eNEMA 416guagesteel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe ELCI provides advanced ground fault protection for electrical systems by detecting leakage currents that may pose a risk of electric shock or fire hazards. It is designed to interrupt the power supply when it detects an imbalance between the hot and neutral conductors, ensuring safety in both residential and industrial applications.\u003c\/p\u003e\n\u003ch4\u003eFeatures :\u003c\/h4\u003e\n\u003cp\u003e• Ground Fault Detection: Quickly detects any leakage currents that could lead to electric shock or fire hazards.\u003c\/p\u003e\n\u003cp\u003e• Adjustable Trip Settings: Allows for customizable trip levels (typically 10mA, 30mA, and 50mA) to match the specific protection requirements.\u003c\/p\u003e\n\u003cp\u003e• Three-Phase Protection: Ideal for three-phase electrical systems, providing protection for commercial and industrial applications.\u003c\/p\u003e\n\u003cp\u003e• Voltage Compatibility: Supports 208\/240V systems for widespread use in residential, commercial, and industrial settings.\u003c\/p\u003e\n\u003cp\u003e• Current Rating: Typically rated at 30A, suitable for medium-sized circuits.\u003c\/p\u003e\n\u003cp\u003e• High Sensitivity: Ensures rapid detection of ground faults, minimizing the risk of electrical shock.\u003c\/p\u003e\n\u003cp\u003e• Reliable and Durable: Built with quality components for long-term performance and safety.\u003c\/p\u003e\n\u003cp\u003e• Enhanced Safety: Provides reliable circuit interruption in the event of ground faults, enhancing overall electrical system safety.\u003c\/p\u003e","brand":"NNC","offers":[{"title":"Default Title","offer_id":63559385678193,"sku":"44620-001","price":1908.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/84_d714a013-e2a4-4b69-b23c-fdd615eb7686.png?v=1777991836"},{"product_id":"208-240v-60a-three-phase-elci-ground-fault-protection-with-10-30-50ma-trip-settings","title":"208\/240V 60A Three-Phase ELCI Ground Fault Protection with 10\/30\/50mA Trip Settings","description":"\u003cp\u003e[pdf]\u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PDF_f8f0387d-28cf-44e8-ac96-295dc059f29f.pdf?v=1777971684\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\" style=\"width: 40.6957%; height: 480.688px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003eVolts\/Amps\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 39.1875px;\"\u003e 208-240V\/60A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003eTripLevel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 39.1875px;\"\u003e10, 30 \u0026amp; 50mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 39.1875px;\"\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 55.1875px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eResponsetime \u003c\/strong\u003e\u003cstrong\u003eforgroundfault\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 55.1875px;\"\u003e25mS-typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 35.5938px;\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eEndurance\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 35.5938px;\"\u003e3,000operationsminimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 55.1875px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eOverload\u003cbr\u003eCurrent\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 55.1875px;\"\u003esixtimesratedcurrent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 55.1875px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eOperating\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003etemperaturerange\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 55.1875px;\"\u003e-20˚Cto+40˚C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 35.5938px;\"\u003e1500VRMS-1Min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 55.1875px;\"\u003e\n\u003cp\u003e\u003cstrong\u003ePower On indication\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 55.1875px;\"\u003elightedindicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eDropoutvoltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 35.5938px;\"\u003e60%ratedvoltage-typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eReset type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center;\"\u003eauto\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eConnection type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center;\"\u003euserattachable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eEnclosure\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center;\"\u003eNEMA 416guagesteel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe ELCI provides advanced ground fault protection for electrical systems by detecting leakage currents that may pose a risk of electric shock or fire hazards. It is designed to interrupt the power supply when it detects an imbalance between the hot and neutral conductors, ensuring safety in both residential and industrial applications.\u003c\/p\u003e\n\u003ch4\u003eFeatures :\u003c\/h4\u003e\n\u003cp\u003e• Ground Fault Detection: Quickly detects any leakage currents that could lead to electric shock or fire hazards.\u003c\/p\u003e\n\u003cp\u003e• Adjustable Trip Settings: Allows for customizable trip levels (typically 10mA, 30mA, and 50mA) to match the specific protection requirements.\u003c\/p\u003e\n\u003cp\u003e• Three-Phase Protection: Ideal for three-phase electrical systems, providing protection for commercial and industrial applications.\u003c\/p\u003e\n\u003cp\u003e• Voltage Compatibility: Supports 208\/240V systems for widespread use in residential, commercial, and industrial settings.\u003c\/p\u003e\n\u003cp\u003e• Current Rating: Typically rated at 30A, suitable for medium-sized circuits.\u003c\/p\u003e\n\u003cp\u003e• High Sensitivity: Ensures rapid detection of ground faults, minimizing the risk of electrical shock.\u003c\/p\u003e\n\u003cp\u003e• Reliable and Durable: Built with quality components for long-term performance and safety.\u003c\/p\u003e\n\u003cp\u003e• Enhanced Safety: Provides reliable circuit interruption in the event of ground faults, enhancing overall electrical system safety.\u003c\/p\u003e","brand":"NNC","offers":[{"title":"Default Title","offer_id":63559445315953,"sku":"44640-001","price":1678.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/84_d714a013-e2a4-4b69-b23c-fdd615eb7686.png?v=1777991836"},{"product_id":"408v-60a-three-phase-elci-ground-fault-protection-with-10-30-50ma-trip-settings","title":"408V 60A Three-Phase ELCI Ground Fault Protection with 10\/30\/50mA Trip Settings","description":"\u003cp\u003e[pdf]\u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PDF_f8f0387d-28cf-44e8-ac96-295dc059f29f.pdf?v=1777971684\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 40.6957%; height: 480.688px;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003eVolts\/Amps\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 39.1875px;\"\u003e 408V\/60A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003eTripLevel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 39.1875px;\"\u003e10, 30 \u0026amp; 50mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 39.1875px;\"\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 55.1875px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eResponsetime \u003c\/strong\u003e\u003cstrong\u003eforgroundfault\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 55.1875px;\"\u003e25mS-typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 35.5938px;\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eEndurance\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 35.5938px;\"\u003e3,000operationsminimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 55.1875px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eOverload\u003cbr\u003eCurrent\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 55.1875px;\"\u003esixtimesratedcurrent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 55.1875px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eOperating\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003etemperaturerange\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 55.1875px;\"\u003e-20˚Cto+40˚C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 35.5938px;\"\u003e1500VRMS-1Min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 55.1875px;\"\u003e\n\u003cp\u003e\u003cstrong\u003ePower On indication\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 55.1875px;\"\u003elightedindicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eDropoutvoltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 35.5938px;\"\u003e60%ratedvoltage-typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eReset type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center;\"\u003eauto\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eConnection type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center;\"\u003euserattachable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eEnclosure\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center;\"\u003eNEMA 416guagesteel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe ELCI provides advanced ground fault protection for electrical systems by detecting leakage currents that may pose a risk of electric shock or fire hazards. It is designed to interrupt the power supply when it detects an imbalance between the hot and neutral conductors, ensuring safety in both residential and industrial applications.\u003c\/p\u003e\n\u003ch4\u003eFeatures :\u003c\/h4\u003e\n\u003cp\u003e• Ground Fault Detection: Quickly detects any leakage currents that could lead to electric shock or fire hazards.\u003c\/p\u003e\n\u003cp\u003e• Adjustable Trip Settings: Allows for customizable trip levels (typically 10mA, 30mA, and 50mA) to match the specific protection requirements.\u003c\/p\u003e\n\u003cp\u003e• Three-Phase Protection: Ideal for three-phase electrical systems, providing protection for commercial and industrial applications.\u003c\/p\u003e\n\u003cp\u003e• Voltage Compatibility: Supports 208\/240V systems for widespread use in residential, commercial, and industrial settings.\u003c\/p\u003e\n\u003cp\u003e• Current Rating: Typically rated at 30A, suitable for medium-sized circuits.\u003c\/p\u003e\n\u003cp\u003e• High Sensitivity: Ensures rapid detection of ground faults, minimizing the risk of electrical shock.\u003c\/p\u003e\n\u003cp\u003e• Reliable and Durable: Built with quality components for long-term performance and safety.\u003c\/p\u003e\n\u003cp\u003e• Enhanced Safety: Provides reliable circuit interruption in the event of ground faults, enhancing overall electrical system safety.\u003c\/p\u003e","brand":"NNC","offers":[{"title":"Default Title","offer_id":63559479820657,"sku":"44630-001","price":2076.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/84_d714a013-e2a4-4b69-b23c-fdd615eb7686.png?v=1777991836"},{"product_id":"240v-30a-elci-ground-fault-protection-with-10ma-trip-setting","title":"240V 30A ELCI Ground Fault Protection with 10mA Trip Setting","description":"\u003cp\u003e[pdf]\u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PDF_af6d236b-9a42-4a7b-b481-db7497d95cc2.pdf?v=1778046360\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\" style=\"width: 40.6957%; height: 480.688px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003eVolts\/Amps\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 39.1875px;\"\u003e240V\/30A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003eTripLevel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 39.1875px;\"\u003e10mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 39.1875px;\"\u003eSingle Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 55.1875px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eResponsetime \u003c\/strong\u003e\u003cstrong\u003eforgroundfault\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 55.1875px;\"\u003e25mS-typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 35.5938px;\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eEndurance\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 35.5938px;\"\u003e3,000operationsminimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 55.1875px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eOverload\u003cbr\u003eCurrent\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 55.1875px;\"\u003esixtimesratedcurrent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 55.1875px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eOperating\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003etemperaturerange\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 55.1875px;\"\u003e-20˚Cto+40˚C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 35.5938px;\"\u003e1500VRMS-1Min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 55.1875px;\"\u003e\n\u003cp\u003e\u003cstrong\u003ePower On indication\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 55.1875px;\"\u003elightedindicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eDropoutvoltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 35.5938px;\"\u003e60%ratedvoltage-typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eReset type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center;\"\u003eauto\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eConnection type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center;\"\u003eflyingleads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eEnclosure\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center;\"\u003eNEMA 4polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eELCI Ground Fault Protection (Earth Leakage Circuit Interrupter) is a safety device used in electrical systems to prevent electrical shock hazards and protect against ground faults. It works by monitoring the current flowing through a circuit, detecting any difference between the live and neutral wires, which indicates a leakage current due to ground faults. When such a fault is detected, the ELCI immediately interrupts the circuit, preventing potential harm to people or damage to equipment.\u003c\/p\u003e\n\u003ch4\u003eFeatures :\u003c\/h4\u003e\n\u003cp\u003e• Ground Fault Protection: Detects ground faults and prevents electrical shocks or fires.\u003c\/p\u003e\n\u003cp\u003e• Trip Settings: Adjustable trip settings (e.g., 10mA, 30mA, 50mA) to accommodate different safety requirements.\u003c\/p\u003e\n\u003cp\u003e• Reliable Circuit Protection: Ensures a safe electrical environment by cutting off power during leakage conditions.\u003c\/p\u003e\n\u003cp\u003e• Multiple Voltage Ratings: Suitable for 208\/240V, 30A, and three-phase systems.\u003c\/p\u003e\n\u003cp\u003e• Easy Installation: Compatible with plug-on neutral systems, making installation simple for electrical panel setups.\u003c\/p\u003e\n\u003cp\u003e• Compliance with Safety Standards: Meets safety regulations for residential, commercial, and industrial electrical systems.\u003c\/p\u003e","brand":"NNC","offers":[{"title":"Default Title","offer_id":63563611111793,"sku":"24140-002","price":300.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/87_da0015fe-d364-4a82-8fcb-246a47d05b57.png?v=1778045288"},{"product_id":"208-240v-30a-elci-ground-fault-protection-with-10ma-trip-setting","title":"208\/240V 30A ELCI Ground Fault Protection with 10mA Trip Setting","description":"\u003cp\u003e[pdf]\u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PDF_af6d236b-9a42-4a7b-b481-db7497d95cc2.pdf?v=1778046360\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 40.6957%; height: 480.688px;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003eVolts\/Amps\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 39.1875px;\"\u003e208\/240V\/30A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003eTripLevel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 39.1875px;\"\u003e10mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 39.1875px;\"\u003eSingle Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 55.1875px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eResponsetime \u003c\/strong\u003e\u003cstrong\u003eforgroundfault\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 55.1875px;\"\u003e25mS-typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 35.5938px;\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eEndurance\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 35.5938px;\"\u003e3,000operationsminimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 55.1875px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eOverload\u003cbr\u003eCurrent\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 55.1875px;\"\u003esixtimesratedcurrent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 55.1875px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eOperating\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003etemperaturerange\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 55.1875px;\"\u003e-20˚Cto+40˚C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 35.5938px;\"\u003e1500VRMS-1Min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 55.1875px;\"\u003e\n\u003cp\u003e\u003cstrong\u003ePower On indication\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 55.1875px;\"\u003elightedindicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eDropoutvoltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 35.5938px;\"\u003e60%ratedvoltage-typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eReset type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center;\"\u003eauto\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eConnection type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center;\"\u003eflyingleads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eEnclosure\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center;\"\u003eNEMA 4polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eELCI Ground Fault Protection (Earth Leakage Circuit Interrupter) is a safety device used in electrical systems to prevent electrical shock hazards and protect against ground faults. It works by monitoring the current flowing through a circuit, detecting any difference between the live and neutral wires, which indicates a leakage current due to ground faults. When such a fault is detected, the ELCI immediately interrupts the circuit, preventing potential harm to people or damage to equipment.\u003c\/p\u003e\n\u003ch4\u003eFeatures :\u003c\/h4\u003e\n\u003cp\u003e• Ground Fault Protection: Detects ground faults and prevents electrical shocks or fires.\u003c\/p\u003e\n\u003cp\u003e• Trip Settings: Adjustable trip settings (e.g., 10mA, 30mA, 50mA) to accommodate different safety requirements.\u003c\/p\u003e\n\u003cp\u003e• Reliable Circuit Protection: Ensures a safe electrical environment by cutting off power during leakage conditions.\u003c\/p\u003e\n\u003cp\u003e• Multiple Voltage Ratings: Suitable for 208\/240V, 30A, and three-phase systems.\u003c\/p\u003e\n\u003cp\u003e• Easy Installation: Compatible with plug-on neutral systems, making installation simple for electrical panel setups.\u003c\/p\u003e\n\u003cp\u003e• Compliance with Safety Standards: Meets safety regulations for residential, commercial, and industrial electrical systems.\u003c\/p\u003e","brand":"NNC","offers":[{"title":"Default Title","offer_id":63563663409521,"sku":"24500-006","price":270.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/87_da0015fe-d364-4a82-8fcb-246a47d05b57.png?v=1778045288"},{"product_id":"240v-60a-three-phase-elci-ground-fault-protector-with-10ma-trip-sensitivity","title":"240V 60A Three-Phase ELCI Ground Fault Protector with 10mA Trip Sensitivity","description":"\u003cp\u003e[pdf]\u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PDF_ba95997b-b1e3-4878-af27-54a015df60f9.pdf?v=1778048093\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\" style=\"width: 40.6957%; height: 480.688px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003eVolts\/Amps\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 39.1875px;\"\u003e240V\/60A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003eTripLevel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 39.1875px;\"\u003e10mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 39.1875px;\"\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 55.1875px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eResponsetime \u003c\/strong\u003e\u003cstrong\u003eforgroundfault\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 55.1875px;\"\u003e25mS-typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 35.5938px;\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eEndurance\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 35.5938px;\"\u003e3,000operationsminimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 55.1875px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eOverload\u003cbr\u003eCurrent\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 55.1875px;\"\u003esixtimesratedcurrent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 55.1875px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eOperating\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003etemperaturerange\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 55.1875px;\"\u003e-20˚Cto+40˚C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 35.5938px;\"\u003e1500VRMS-1Min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 55.1875px;\"\u003e\n\u003cp\u003e\u003cstrong\u003ePower On indication\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 55.1875px;\"\u003elightedindicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eDropoutvoltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 35.5938px;\"\u003e60%ratedvoltage-typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eReset type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center;\"\u003eauto\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eConnection type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center;\"\u003eflyingleads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eEnclosure\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center;\"\u003eNEMA 4polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eELCI Ground Fault Protection (Earth Leakage Circuit Interrupter) is a safety device used in electrical systems to prevent electrical shock hazards and protect against ground faults. It works by monitoring the current flowing through a circuit, detecting any difference between the live and neutral wires, which indicates a leakage current due to ground faults. When such a fault is detected, the ELCI immediately interrupts the circuit, preventing potential harm to people or damage to equipment.\u003c\/p\u003e\n\u003ch4\u003eFeatures :\u003c\/h4\u003e\n\u003cp\u003e• Ground Fault Protection: Detects ground faults and prevents electrical shocks or fires.\u003c\/p\u003e\n\u003cp\u003e• Trip Settings: Adjustable trip settings (e.g., 10mA, 30mA, 50mA) to accommodate different safety requirements.\u003c\/p\u003e\n\u003cp\u003e• Reliable Circuit Protection: Ensures a safe electrical environment by cutting off power during leakage conditions.\u003c\/p\u003e\n\u003cp\u003e• Multiple Voltage Ratings: Suitable for 208\/240V, 30A, and three-phase systems.\u003c\/p\u003e\n\u003cp\u003e• Easy Installation: Compatible with plug-on neutral systems, making installation simple for electrical panel setups.\u003c\/p\u003e\n\u003cp\u003e• Compliance with Safety Standards: Meets safety regulations for residential, commercial, and industrial electrical systems.\u003c\/p\u003e","brand":"NNC","offers":[{"title":"Default Title","offer_id":63563842617713,"sku":"24530-001","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/88_eaa0e7a5-11d9-4928-8519-c4465be41ab0.png?v=1778047844"},{"product_id":"277v-30a-three-phase-elci-ground-fault-protector-with-10-30-50ma-trip-sensitivity","title":"277V 30A Three-Phase ELCI Ground Fault Protector with 10\/30\/50mA Trip Sensitivity","description":"\u003cp\u003e[pdf]\u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PDF_42ac0de7-5562-40de-bb63-d74a3c14210b.pdf?v=1778050102\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 40.6957%; height: 480.688px;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003eVolts\/Amps\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 39.1875px;\"\u003e277V\/30A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003eTripLevel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 39.1875px;\"\u003e10mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center;\"\u003e\u003cstrong\u003eCord Gauge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center;\"\u003e10\/3 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 39.1875px;\"\u003eSingle Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 55.1875px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eResponsetime \u003c\/strong\u003e\u003cstrong\u003eforgroundfault\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 55.1875px;\"\u003e25mS-typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 35.5938px;\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eEndurance\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 35.5938px;\"\u003e3,000operationsminimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 55.1875px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eOverload\u003cbr\u003eCurrent\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 55.1875px;\"\u003esixtimesratedcurrent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 55.1875px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eOperating\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003etemperaturerange\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 55.1875px;\"\u003e-20˚Cto+40˚C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 35.5938px;\"\u003e1500VRMS-1Min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 55.1875px;\"\u003e\n\u003cp\u003e\u003cstrong\u003ePower On indication\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 55.1875px;\"\u003elightedindicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eDropoutvoltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 35.5938px;\"\u003e60%ratedvoltage-typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eReset type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center;\"\u003eauto\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eConnection type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center;\"\u003eflyingleads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eEnclosure\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center;\"\u003eNEMA 4polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eELCI Ground Fault Protection (Earth Leakage Circuit Interrupter) is a safety device used in electrical systems to prevent electrical shock hazards and protect against ground faults. It works by monitoring the current flowing through a circuit, detecting any difference between the live and neutral wires, which indicates a leakage current due to ground faults. When such a fault is detected, the ELCI immediately interrupts the circuit, preventing potential harm to people or damage to equipment.\u003c\/p\u003e\n\u003ch4\u003eFeatures :\u003c\/h4\u003e\n\u003cp\u003e• Ground Fault Protection: Detects ground faults and prevents electrical shocks or fires.\u003c\/p\u003e\n\u003cp\u003e• Trip Settings: Adjustable trip settings (e.g., 10mA, 30mA, 50mA) to accommodate different safety requirements.\u003c\/p\u003e\n\u003cp\u003e• Reliable Circuit Protection: Ensures a safe electrical environment by cutting off power during leakage conditions.\u003c\/p\u003e\n\u003cp\u003e• Multiple Voltage Ratings: Suitable for 208\/240V, 30A, and three-phase systems.\u003c\/p\u003e\n\u003cp\u003e• Easy Installation: Compatible with plug-on neutral systems, making installation simple for electrical panel setups.\u003c\/p\u003e\n\u003cp\u003e• Compliance with Safety Standards: Meets safety regulations for residential, commercial, and industrial electrical systems.\u003c\/p\u003e","brand":"NNC","offers":[{"title":"Default Title","offer_id":63563903861105,"sku":"24396-001","price":858.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/88_eaa0e7a5-11d9-4928-8519-c4465be41ab0.png?v=1778047844"},{"product_id":"600v-60a-three-phase-elci-ground-fault-protector-with-6-10-30ma-trip-sensitivity","title":"600V 60A Three-Phase ELCI Ground Fault Protector with 6\/10\/30mA Trip Sensitivity","description":"\u003cp\u003e[pdf]\u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PDF_fd4f5d84-784d-42be-85c4-8f594de4c0f0.pdf?v=1778051866\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\" style=\"width: 40.6957%; height: 480.688px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003eVolts\/Amps\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 39.1875px;\"\u003e600V\/60A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003eTripLevel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 39.1875px;\"\u003e6\/10\/30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center;\"\u003e\u003cstrong\u003eCord Gauge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center;\"\u003e4\/4 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 39.1875px;\"\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 55.1875px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eResponsetime \u003c\/strong\u003e\u003cstrong\u003eforgroundfault\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 55.1875px;\"\u003e25mS-typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 35.5938px;\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eEndurance\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 35.5938px;\"\u003e3,000operationsminimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 55.1875px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eOverload\u003cbr\u003eCurrent\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 55.1875px;\"\u003esixtimesratedcurrent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 55.1875px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eOperating\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003etemperaturerange\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 55.1875px;\"\u003e-20˚Cto+40˚C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 35.5938px;\"\u003e1500VRMS-1Min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 55.1875px;\"\u003e\n\u003cp\u003e\u003cstrong\u003ePower On indication\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 55.1875px;\"\u003elightedindicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eDropoutvoltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 35.5938px;\"\u003e60%ratedvoltage-typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eReset type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center;\"\u003eauto\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eConnection type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center;\"\u003eflyingleads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eEnclosure\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center;\"\u003eNEMA 4polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eELCI Ground Fault Protection (Earth Leakage Circuit Interrupter) is a safety device used in electrical systems to prevent electrical shock hazards and protect against ground faults. It works by monitoring the current flowing through a circuit, detecting any difference between the live and neutral wires, which indicates a leakage current due to ground faults. When such a fault is detected, the ELCI immediately interrupts the circuit, preventing potential harm to people or damage to equipment.\u003c\/p\u003e\n\u003ch4\u003eFeatures :\u003c\/h4\u003e\n\u003cp\u003e• Ground Fault Protection: Detects ground faults and prevents electrical shocks or fires.\u003c\/p\u003e\n\u003cp\u003e• Trip Settings: Adjustable trip settings (e.g., 10mA, 30mA, 50mA) to accommodate different safety requirements.\u003c\/p\u003e\n\u003cp\u003e• Reliable Circuit Protection: Ensures a safe electrical environment by cutting off power during leakage conditions.\u003c\/p\u003e\n\u003cp\u003e• Multiple Voltage Ratings: Suitable for 208\/240V, 30A, and three-phase systems.\u003c\/p\u003e\n\u003cp\u003e• Easy Installation: Compatible with plug-on neutral systems, making installation simple for electrical panel setups.\u003c\/p\u003e\n\u003cp\u003e• Compliance with Safety Standards: Meets safety regulations for residential, commercial, and industrial electrical systems.\u003c\/p\u003e","brand":"NNC","offers":[{"title":"Default Title","offer_id":63563917525361,"sku":"24946-003","price":4116.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/89_e1ca6c36-7c82-4ae9-8b9b-03257f2b08c5.png?v=1778051549"},{"product_id":"600v-80a-three-phase-elci-ground-fault-protector-with-6-10-30ma-trip-sensitivity","title":"600V 80A Three-Phase ELCI Ground Fault Protector with 6\/10\/30mA Trip Sensitivity","description":"\u003cp\u003e[pdf]\u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/PDF_fd4f5d84-784d-42be-85c4-8f594de4c0f0.pdf?v=1778051866\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 40.6957%; height: 480.688px;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003eVolts\/Amps\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 39.1875px;\"\u003e600V\/80A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003eTripLevel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 39.1875px;\"\u003e6\/10\/30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center;\"\u003e\u003cstrong\u003eCord Gauge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center;\"\u003e4\/4 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 39.1875px;\"\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 39.1875px;\"\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 55.1875px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eResponsetime \u003c\/strong\u003e\u003cstrong\u003eforgroundfault\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 55.1875px;\"\u003e25mS-typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 35.5938px;\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eEndurance\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 35.5938px;\"\u003e3,000operationsminimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 55.1875px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eOverload\u003cbr\u003eCurrent\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 55.1875px;\"\u003esixtimesratedcurrent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 55.1875px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eOperating\u003cbr\u003e\u003c\/strong\u003e\u003cstrong\u003etemperaturerange\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 55.1875px;\"\u003e-20˚Cto+40˚C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 35.5938px;\"\u003e1500VRMS-1Min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 55.1875px;\"\u003e\n\u003cp\u003e\u003cstrong\u003ePower On indication\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 55.1875px;\"\u003elightedindicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eDropoutvoltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center; height: 35.5938px;\"\u003e60%ratedvoltage-typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eReset type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center;\"\u003eauto\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eConnection type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center;\"\u003eflyingleads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.0346%; text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eEnclosure\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 60.0804%; text-align: center;\"\u003eNEMA 4polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eELCI Ground Fault Protection (Earth Leakage Circuit Interrupter) is a safety device used in electrical systems to prevent electrical shock hazards and protect against ground faults. It works by monitoring the current flowing through a circuit, detecting any difference between the live and neutral wires, which indicates a leakage current due to ground faults. When such a fault is detected, the ELCI immediately interrupts the circuit, preventing potential harm to people or damage to equipment.\u003c\/p\u003e\n\u003ch4\u003eFeatures :\u003c\/h4\u003e\n\u003cp\u003e• Ground Fault Protection: Detects ground faults and prevents electrical shocks or fires.\u003c\/p\u003e\n\u003cp\u003e• Trip Settings: Adjustable trip settings (e.g., 10mA, 30mA, 50mA) to accommodate different safety requirements.\u003c\/p\u003e\n\u003cp\u003e• Reliable Circuit Protection: Ensures a safe electrical environment by cutting off power during leakage conditions.\u003c\/p\u003e\n\u003cp\u003e• Multiple Voltage Ratings: Suitable for 208\/240V, 30A, and three-phase systems.\u003c\/p\u003e\n\u003cp\u003e• Easy Installation: Compatible with plug-on neutral systems, making installation simple for electrical panel setups.\u003c\/p\u003e\n\u003cp\u003e• Compliance with Safety Standards: Meets safety regulations for residential, commercial, and industrial electrical systems.\u003c\/p\u003e","brand":"NNC","offers":[{"title":"Default Title","offer_id":63563923718513,"sku":"24992-001","price":2394.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/89_e1ca6c36-7c82-4ae9-8b9b-03257f2b08c5.png?v=1778051549"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/collections\/88_eaa0e7a5-11d9-4928-8519-c4465be41ab0.png?v=1778054840","url":"https:\/\/nassaunationalcable.com\/collections\/elci-egfpd-ground-fault-protection-devices.oembed","provider":"NassauNationalCable","version":"1.0","type":"link"}