{"title":"Copper EPR \/ LLDPE Concentric Neutral MV-90 Primary UD Cable 5 kV - 46 kV","description":"","products":[{"product_id":"2-awg-7-str-copper-primary-ud-cable-14-awg-1-3-neutral-epr-lldpe-mv-90-100-90-mil-5-kv","title":"2 AWG 7 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 90 mil 5 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_1.pdf?v=1743147152\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2 AWG 7 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 90 mil 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e2 AWG Copper EPR cable, MV-90 UD cable, 2 AWG 5kV-46kV cable, Primary UD cable, Medium voltage cable, Concentric neutral cable, 2 AWG Underground distribution cable, 2 AWG MV power cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 7\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.50\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 6\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e14\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 0.81\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 484 \u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52215057514865,"sku":"NNC2UDEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-30T130525.602.png?v=1763023708"},{"product_id":"1-awg-19-str-copper-primary-ud-cable-14-awg-1-3-neutral-epr-lldpe-mv-90-100-90-mil-5-kv","title":"1 AWG 19 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 90 mil 5 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_1.pdf?v=1743147152\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1 AWG 19 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 90 mil 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1 AWG Copper EPR cable, MV-90 UD cable, 1 AWG 5kV-46kV cable, Primary UD cable, Medium voltage cable, Concentric neutral cable, 1 AWG Underground distribution cable, 1 AWG MV power cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.54\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 7\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e14\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 0.84 \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 564\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52215060824433,"sku":"NNC1UDEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-30T130525.602.png?v=1763023708"},{"product_id":"1-0-awg-19-str-copper-primary-ud-cable-14-awg-1-3-neutral-epr-lldpe-mv-90-100-90-mil-5-kv","title":"1\/0 AWG 19 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 90 mil 5 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_1.pdf?v=1743147152\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1\/0 AWG 19 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 90 mil 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1\/0 AWG Copper EPR cable, MV-90 UD cable, 1\/0 AWG 5kV-46kV cable, Primary UD cable, Medium voltage cable, Concentric neutral cable, 1\/0 AWG Underground distribution cable, 1\/0 AWG MV power cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1\/0 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.58\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 9\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e14\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 0.88\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 672\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52215062856049,"sku":"NNC1\/0UDEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-30T130525.602.png?v=1763023708"},{"product_id":"2-0-awg-19-str-copper-primary-ud-cable-14-awg-1-3-neutral-epr-lldpe-mv-90-100-90-mil-5-kv","title":"2\/0 AWG 19 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 90 mil 5 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_1.pdf?v=1743147152\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2\/0 AWG 19 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 90 mil 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e2\/0 AWG Copper EPR cable, MV-90 UD cable, 2\/0 AWG 5kV-46kV cable, Primary UD cable, Medium voltage cable, Concentric neutral cable, 2\/0 AWG Underground distribution cable, 2\/0 AWG MV power cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2\/0 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.63\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 11\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e14\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 0.93 \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 799\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52215066755441,"sku":"NNC2\/0UDEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-30T130525.602.png?v=1763023708"},{"product_id":"3-0-awg-19-str-copper-primary-ud-cable-14-awg-1-3-neutral-epr-lldpe-mv-90-100-90-mil-5-kv","title":"3\/0 AWG 19 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 90 mil 5 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_1.pdf?v=1743147152\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e3\/0 AWG 19 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 90 mil 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e3\/0 AWG Copper EPR cable, MV-90 UD cable, 3\/0 AWG 5kV-46kV cable, Primary UD cable, Medium voltage cable, Concentric neutral cable, 3\/0 AWG Underground distribution cable, 3\/0 AWG MV power cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 3\/0 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.68\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 14\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e14\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 0.98\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 963\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52215068754289,"sku":"NNC3\/0UDEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-30T130525.602.png?v=1763023708"},{"product_id":"4-0-awg-19-str-copper-primary-ud-cable-14-awg-1-3-neutral-epr-lldpe-mv-90-100-90-mil-5-kv","title":"4\/0 AWG 19 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 90 mil 5 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_1.pdf?v=1743147152\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e4\/0 AWG 19 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 90 mil 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e4\/0 AWG Copper EPR cable, MV-90 UD cable, 4\/0 AWG 5kV-46kV cable, Primary UD cable, Medium voltage cable, Concentric neutral cable, 4\/0 AWG Underground distribution cable, 4\/0 AWG MV power cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 4\/0 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.73\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 18\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e14\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.03\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 1170\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52215069933937,"sku":"NNC4\/0UDEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-30T130525.602.png?v=1763023708"},{"product_id":"250-mcm-37-str-copper-primary-ud-cable-12-awg-1-3-neutral-epr-lldpe-mv-90-100-90-mil-5-kv","title":"250 MCM 37 Str Copper Primary UD Cable 12 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 90 mil 5 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_1.pdf?v=1743147152\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e250 MCM 37 Str Copper Primary UD Cable 12 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 90 mil 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e250 MCM Copper EPR cable, MV-90 UD cable, 250 MCM 5kV-46kV cable, Primary UD cable, Medium voltage cable, Concentric neutral cable, 250 MCM Underground distribution cable, 250 MCM MV power cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 250 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 37\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.79\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 13\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e12 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.12\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 1366\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52215070687601,"sku":"NNC250UDEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-30T130525.602.png?v=1763023708"},{"product_id":"350-mcm-37-str-copper-primary-ud-cable-12-awg-1-3-neutral-epr-lldpe-mv-90-100-90-mil-5-kv","title":"350 MCM 37 Str Copper Primary UD Cable 12 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 90 mil 5 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_1.pdf?v=1743147152\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e350 MCM 37 Str Copper Primary UD Cable 12 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 90 mil 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e350 MCM Copper EPR cable, MV-90 UD cable, 350 MCM 5kV-46kV cable, Primary UD cable, Medium voltage cable, Concentric neutral cable, 350 MCM Underground distribution cable, 350 MCM MV power cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 350 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 37\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.89\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 18\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e12 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.23\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 1815\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52215072555377,"sku":"NNC350UDEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-30T130525.602.png?v=1763023708"},{"product_id":"500-mcm-37-str-copper-primary-ud-cable-10-awg-1-3-neutral-epr-lldpe-mv-90-100-90-mil-5-kv","title":"500 MCM 37 Str Copper Primary UD Cable 10 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 90 mil 5 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_1.pdf?v=1743147152\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e500 MCM 37 Str Copper Primary UD Cable 10 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 90 mil 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e500 MCM Copper EPR cable, MV-90 UD cable, 500 MCM 5kV-46kV cable, Primary UD cable, Medium voltage cable, Concentric neutral cable, 500 MCM Underground distribution cable, 500 MCM MV power cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 500 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 37\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.02\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 17\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e10 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.42\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 2569\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52215072948593,"sku":"NNC500UDEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-30T130525.602.png?v=1763023708"},{"product_id":"750-mcm-61-str-copper-primary-ud-cable-9-awg-1-3-neutral-epr-lldpe-mv-90-100-90-mil-5-kv","title":"750 MCM 61 Str Copper Primary UD Cable 9 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 90 mil 5 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_1.pdf?v=1743147152\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e750 MCM 61 Str Copper Primary UD Cable 9 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 90 mil 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e750 MCM Copper EPR cable, MV-90 UD cable, 750 MCM 5kV-46kV cable, Primary UD cable, Medium voltage cable, Concentric neutral cable, 750 MCM Underground distribution cable, 750 MCM MV power cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 750 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 61\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.21 \u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 20\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e9\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 80\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.70\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 3773\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52215074455921,"sku":"NNC750UDEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-30T130525.602.png?v=1763023708"},{"product_id":"1000-mcm-61-str-copper-primary-ud-cable-9-awg-1-3-neutral-epr-lldpe-mv-90-100-90-mil-5-kv","title":"1000 MCM 61 Str Copper Primary UD Cable 9 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 90 mil 5 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_1.pdf?v=1743147152\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1000 MCM 61 Str Copper Primary UD Cable 9 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 90 mil 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1000 MCM Copper EPR cable, MV-90 UD cable, 1000 MCM 5kV-46kV cable, Primary UD cable, Medium voltage cable, Concentric neutral cable, 1000 MCM Underground distribution cable, 1000 MCM MV power cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1000 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 61\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.36\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 26 \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e9\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 80\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.85\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 4854 \u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52215076782449,"sku":"NNC1000UDEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-30T130525.602.png?v=1763023708"},{"product_id":"2-awg-7-str-copper-primary-ud-cable-14-awg-full-neutral-epr-lldpe-mv-90-100-90-mil-5-kv","title":"2 AWG 7 Str Copper Primary UD Cable 14 AWG Full Neutral EPR \/ LLDPE MV-90 100% 90 mil 5 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_1.pdf?v=1743147152\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2 AWG 7 Str Copper Primary UD Cable 14 AWG Full Neutral EPR \/ LLDPE MV-90 100% 90 mil 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e2 AWG Copper EPR cable, MV-90 UD cable, 2 AWG 5kV-46kV cable, Primary UD cable, Medium voltage cable, Concentric neutral cable, 2 AWG Underground distribution cable, 2 AWG MV power cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 7\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.50\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 16\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e14\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eAWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 0.81\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 604\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52215078879601,"sku":"NNC02UDEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-30T130525.602.png?v=1763023708"},{"product_id":"1-awg-19-str-copper-primary-ud-cable-12-awg-full-neutral-epr-lldpe-mv-90-100-90-mil-5-kv","title":"1 AWG 19 Str Copper Primary UD Cable 12 AWG Full Neutral EPR \/ LLDPE MV-90 100% 90 mil 5 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_1.pdf?v=1743147152\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1 AWG 19 Str Copper Primary UD Cable 12 AWG Full Neutral EPR \/ LLDPE MV-90 100% 90 mil 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1 AWG Copper EPR cable, MV-90 UD cable, 1 AWG 5kV-46kV cable, Primary UD cable, Medium voltage cable, Concentric neutral cable, 1 AWG Underground distribution cable, 1 AWG MV power cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.54\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 13\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e12 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 0.88\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 747\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52215080354161,"sku":"NNC01UDEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-30T130525.602.png?v=1763023708"},{"product_id":"1-0-awg-19-str-copper-primary-ud-cable-12-awg-full-neutral-epr-lldpe-mv-90-100-90-mil-5-kv","title":"1\/0 AWG 19 Str Copper Primary UD Cable 12 AWG Full Neutral EPR \/ LLDPE MV-90 100% 90 mil 5 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_1.pdf?v=1743147152\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1\/0 AWG 19 Str Copper Primary UD Cable 12 AWG Full Neutral EPR \/ LLDPE MV-90 100% 90 mil 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1\/0 AWG Copper EPR cable, MV-90 UD cable, 1\/0 AWG 5kV-46kV cable, Primary UD cable, Medium voltage cable, Concentric neutral cable, 1\/0 AWG Underground distribution cable, 1\/0 AWG MV power cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.58 \u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 16\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e12 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 0.92\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 889\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52215081599345,"sku":"NNC01\/0UDEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-30T130525.602.png?v=1763023708"},{"product_id":"2-0-awg-19-str-copper-primary-ud-cable-10-awg-full-neutral-epr-lldpe-mv-90-100-90-mil-5-kv","title":"2\/0 AWG 19 Str Copper Primary UD Cable 10 AWG Full Neutral EPR \/ LLDPE MV-90 100% 90 mil 5 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_1.pdf?v=1743147152\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2\/0 AWG 19 Str Copper Primary UD Cable 10 AWG Full Neutral EPR \/ LLDPE MV-90 100% 90 mil 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e2\/0 AWG Copper EPR cable, MV-90 UD cable, 2\/0 AWG 5kV-46kV cable, Primary UD cable, Medium voltage cable, Concentric neutral cable, 2\/0 AWG Underground distribution cable, 2\/0 AWG MV power cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.63\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 13\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e10 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.00 \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 1109\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52215082582385,"sku":"NNC02\/0UDEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-30T130525.602.png?v=1763023708"},{"product_id":"3-0-awg-19-str-copper-primary-ud-cable-10-awg-full-neutral-epr-lldpe-mv-90-100-90-mil-5-kv","title":"3\/0 AWG 19 Str Copper Primary UD Cable 10 AWG Full Neutral EPR \/ LLDPE MV-90 100% 90 mil 5 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_1.pdf?v=1743147152\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e3\/0 AWG 19 Str Copper Primary UD Cable 10 AWG Full Neutral EPR \/ LLDPE MV-90 100% 90 mil 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e3\/0 AWG Copper EPR cable, MV-90 UD cable, 3\/0 AWG 5kV-46kV cable, Primary UD cable, Medium voltage cable, Concentric neutral cable, 3\/0 AWG Underground distribution cable, 3\/0 AWG MV power cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 3\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.68\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 16\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e10 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.05\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 1331\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52215084122481,"sku":"NNC03\/0UDEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-30T130525.602.png?v=1763023708"},{"product_id":"4-0-awg-19-str-copper-primary-ud-cable-9-awg-full-neutral-epr-lldpe-mv-90-100-90-mil-5-kv","title":"4\/0 AWG 19 Str Copper Primary UD Cable 9 AWG Full Neutral EPR \/ LLDPE MV-90 100% 90 mil 5 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_1.pdf?v=1743147152\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e4\/0 AWG 19 Str Copper Primary UD Cable 9 AWG Full Neutral EPR \/ LLDPE MV-90 100% 90 mil 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e4\/0 AWG Copper EPR cable, MV-90 UD cable, 4\/0 AWG 5kV-46kV cable, Primary UD cable, Medium voltage cable, Concentric neutral cable, 4\/0 AWG Underground distribution cable, 4\/0 AWG MV power cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 4\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.73 \u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 16\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e9 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.14\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 1637\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52215086580081,"sku":"NNC04\/0UDEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-30T130525.602.png?v=1763023708"},{"product_id":"250-mcm-37-str-copper-primary-ud-cable-10-awg-full-neutral-epr-lldpe-mv-90-100-90-mil-5-kv","title":"250 MCM 37 Str Copper Primary UD Cable 10 AWG Full Neutral EPR \/ LLDPE MV-90 100% 90 mil 5 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_1.pdf?v=1743147152\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e250 MCM 37 Str Copper Primary UD Cable 10 AWG Full Neutral EPR \/ LLDPE MV-90 100% 90 mil 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e250 MCM Copper EPR cable, MV-90 UD cable, 250 MCM 5kV-46kV cable, Primary UD cable, Medium voltage cable, Concentric neutral cable, 250 MCM Underground distribution cable, 250 MCM MV power cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 250 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 37\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.79\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 25\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e10 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.17\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 1910\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52215100342641,"sku":"NNC0250UDEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-30T130525.602.png?v=1763023708"},{"product_id":"350-mcm-37-str-copper-primary-ud-cable-8-awg-full-neutral-epr-lldpe-mv-90-100-90-mil-5-kv","title":"350 MCM 37 Str Copper Primary UD Cable 8 AWG Full Neutral EPR \/ LLDPE MV-90 100% 90 mil 5 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_1.pdf?v=1743147152\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e350 MCM 37 Str Copper Primary UD Cable 8 AWG Full Neutral EPR \/ LLDPE MV-90 100% 90 mil 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e350 MCM Copper EPR cable, MV-90 UD cable, 350 MCM 5kV-46kV cable, Primary UD cable, Medium voltage cable, Concentric neutral cable, 350 MCM Underground distribution cable, 350 MCM MV power cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 350 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 37\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.89\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 22\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e8 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.32\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 2614\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52215102570865,"sku":"NNC0350UDEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-30T130525.602.png?v=1763023708"},{"product_id":"500-mcm-37-str-copper-primary-ud-cable-8-awg-full-neutral-epr-lldpe-mv-90-100-90-mil-5-kv","title":"500 MCM 37 Str Copper Primary UD Cable 8 AWG Full Neutral EPR \/ LLDPE MV-90 100% 90 mil 5 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_1.pdf?v=1743147152\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e500 MCM 37 Str Copper Primary UD Cable 8 AWG Full Neutral EPR \/ LLDPE MV-90 100% 90 mil 5 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e500 MCM Copper EPR cable, MV-90 UD cable, 500 MCM 5kV-46kV cable, Primary UD cable, Medium voltage cable, Concentric neutral cable, 500 MCM Underground distribution cable, 500 MCM MV power cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 500 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 37\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.02\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 31 \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e8 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.47\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 3603\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52215107649905,"sku":"NNC0500UDEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-30T130525.602.png?v=1763023708"},{"product_id":"2-awg-7-str-copper-primary-ud-cable-14-awg-1-3-neutral-epr-lldpe-mv-90-100-115-mil-8-kv","title":"2 AWG 7 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 115 mil 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_1.pdf?v=1743147152\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2 AWG 7 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 115 mil 8 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e2 AWG Copper EPR cable, MV-90 UD cable, 2 AWG 5kV-46kV cable, Primary UD cable, Medium voltage cable, Concentric neutral cable, 2 AWG Underground distribution cable, 2 AWG MV power cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 7\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.55\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 6\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e14 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 0.86 \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 517\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52215179641201,"sku":"NNC21UDEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-30T130525.602.png?v=1763023708"},{"product_id":"1-awg-19-str-copper-primary-ud-cable-14-awg-1-3-neutral-epr-lldpe-mv-90-100-115-mil-8-kv","title":"1 AWG 19 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 115 mil 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_1.pdf?v=1743147152\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1 AWG 19 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 115 mil 8 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1 AWG Copper EPR cable, MV-90 UD cable, 1 AWG 5kV-46kV cable, Primary UD cable, Medium voltage cable, Concentric neutral cable, 1 AWG Underground distribution cable, 1 AWG MV power cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.59\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 7\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e14 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 0.90\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 598\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52215189995889,"sku":"NNC11UDEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-30T130525.602.png?v=1763023708"},{"product_id":"1-0-awg-19-str-copper-primary-ud-cable-14-awg-1-3-neutral-epr-lldpe-mv-90-100-115-mil-8-kv","title":"1\/0 AWG 19 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 115 mil 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_1.pdf?v=1743147152\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1\/0 AWG 19 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 115 mil 8 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1\/0 AWG  Copper EPR cable, MV-90 UD cable, 1\/0 AWG  5kV-46kV cable, Primary UD cable, Medium voltage cable, Concentric neutral cable, 1\/0 AWG Underground distribution cable, 1\/0 AWG  MV power cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1\/0 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.63\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 9\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e14 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 0.94\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 708\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52215191961969,"sku":"NNC11\/0UDEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-30T130525.602.png?v=1763023708"},{"product_id":"2-0-awg-19-str-copper-primary-ud-cable-14-awg-1-3-neutral-epr-lldpe-mv-90-100-115-mil-8-kv","title":"2\/0 AWG 19 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 115 mil 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_1.pdf?v=1743147152\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2\/0 AWG 19 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 115 mil 8 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e2\/0 AWG  Copper EPR cable, MV-90 UD cable, 2\/0 AWG  5kV-46kV cable, Primary UD cable, Medium voltage cable, Concentric neutral cable, 2\/0 AWG Underground distribution cable, 2\/0 AWG  MV power cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2\/0 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.68\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 11 \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e14 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 0.98\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 837\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52215193928049,"sku":"NNC12\/0UDEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-30T130525.602.png?v=1763023708"},{"product_id":"3-0-awg-19-str-copper-primary-ud-cable-14-awg-1-3-neutral-epr-lldpe-mv-90-100-115-mil-8-kv","title":"3\/0 AWG 19 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 115 mil 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_1.pdf?v=1743147152\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e3\/0 AWG 19 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 115 mil 8 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e3\/0 AWG  Copper EPR cable, MV-90 UD cable, 3\/0 AWG  5kV-46kV cable, Primary UD cable, Medium voltage cable, Concentric neutral cable, 3\/0 AWG Underground distribution cable, 3\/0 AWG  MV power cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 3\/0 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.73\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 14\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e14 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.03\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 1003\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52215194878321,"sku":"NNC13\/0UDEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-30T130525.602.png?v=1763023708"},{"product_id":"4-0-awg-19-str-copper-primary-ud-cable-14-awg-1-3-neutral-epr-lldpe-mv-90-100-115-mil-8-kv","title":"4\/0 AWG 19 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 115 mil 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_1.pdf?v=1743147152\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e4\/0 AWG 19 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 115 mil 8 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e4\/0 AWG  Copper EPR cable, MV-90 UD cable, 4\/0 AWG  5kV-46kV cable, Primary UD cable, Medium voltage cable, Concentric neutral cable, 4\/0 AWG Underground distribution cable, 4\/0 AWG MV power cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 4\/0 AWG \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.78\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 18\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e14 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.09\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 1212\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52215195926897,"sku":"NNC14\/0UDEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-30T130525.602.png?v=1763023708"},{"product_id":"250-mcm-37-str-copper-primary-ud-cable-12-awg-1-3-neutral-epr-lldpe-mv-90-100-115-mil-8-kv","title":"250 MCM 37 Str Copper Primary UD Cable 12 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 115 mil 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_1.pdf?v=1743147152\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e250 MCM 37 Str Copper Primary UD Cable 12 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 115 mil 8 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e250 MCM Copper EPR cable, MV-90 UD cable, 250 MCM 5kV-46kV cable, Primary UD cable, Medium voltage cable, Concentric neutral cable, 250 MCM Underground distribution cable, 250 MCM MV power cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 250 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 37\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.84\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 13\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e12 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.18\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 1412\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52215197827441,"sku":"NNC1250UDEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-30T130525.602.png?v=1763023708"},{"product_id":"350-mcm-37-str-copper-primary-ud-cable-12-awg-1-3-neutral-epr-lldpe-mv-90-100-115-mil-8-kv","title":"350 MCM 37 Str Copper Primary UD Cable 12 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 115 mil 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_1.pdf?v=1743147152\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e350 MCM 37 Str Copper Primary UD Cable 12 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 115 mil 8 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e350 MCM Copper EPR cable, MV-90 UD cable, 350 MCM 5kV-46kV cable, Primary UD cable, Medium voltage cable, Concentric neutral cable, 350 MCM Underground distribution cable, 350 MCM MV power cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 350 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 37\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.94\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 18\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e12 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.28\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 1865\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52215199400305,"sku":"NNC1350UDEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-30T130525.602.png?v=1763023708"},{"product_id":"500-mcm-37-str-copper-primary-ud-cable-10-awg-1-3-neutral-epr-lldpe-mv-90-100-115-mil-8-kv","title":"500 MCM 37 Str Copper Primary UD Cable 10 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 115 mil 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_1.pdf?v=1743147152\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e500 MCM 37 Str Copper Primary UD Cable 10 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 115 mil 8 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e500 MCM Copper EPR cable, MV-90 UD cable, 500 MCM 5kV-46kV cable, Primary UD cable, Medium voltage cable, Concentric neutral cable, 500 MCM Underground distribution cable, 500 MCM MV power cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 500 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 37\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.07\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 17\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e10 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.47\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 2627\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52215200809329,"sku":"NNC1500UDEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-30T130525.602.png?v=1763023708"},{"product_id":"750-mcm-61-str-copper-primary-ud-cable-9-awg-1-3-neutral-epr-lldpe-mv-90-100-115-mil-8-kv","title":"750 MCM 61 Str Copper Primary UD Cable 9 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 115 mil 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_1.pdf?v=1743147152\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e750 MCM 61 Str Copper Primary UD Cable 9 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 115 mil 8 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e750 MCM Copper EPR cable, MV-90 UD cable, 750 MCM 5kV-46kV cable, Primary UD cable, Medium voltage cable, Concentric neutral cable, 750 MCM Underground distribution cable, 750 MCM MV power cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 750 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 61\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.26\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 20\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e9 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 80\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.75\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 3841 \u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52215202185585,"sku":"NNC1750UDEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-30T130525.602.png?v=1763023708"},{"product_id":"1000-mcm-61-str-copper-primary-ud-cable-9-awg-1-3-neutral-epr-lldpe-mv-90-100-115-mil-8-kv","title":"1000 MCM 61 Str Copper Primary UD Cable 9 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 115 mil 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_1.pdf?v=1743147152\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1000 MCM 61 Str Copper Primary UD Cable 9 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 115 mil 8 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1000 MCM Copper EPR cable, MV-90 UD cable, 1000 MCM 5kV-46kV cable, Primary UD cable, Medium voltage cable, Concentric neutral cable, 1000 MCM Underground distribution cable, 1000 MCM MV power cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1000 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 61\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.41\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 26\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e9 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 80\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.90\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 4929\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52215203266929,"sku":"NNC11000UDEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-30T130525.602.png?v=1763023708"},{"product_id":"2-awg-7-str-copper-primary-ud-cable-14-awg-full-neutral-epr-lldpe-mv-90-100-115-mil-8-kv","title":"2 AWG 7 Str Copper Primary UD Cable 14 AWG Full Neutral EPR \/ LLDPE MV-90 100% 115 mil 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_1.pdf?v=1743147152\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2 AWG 7 Str Copper Primary UD Cable 14 AWG Full Neutral EPR \/ LLDPE MV-90 100% 115 mil 8 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e2 AWG Copper EPR cable, MV-90 UD cable, 2 AWG 5kV-46kV cable, Primary UD cable, Medium voltage cable, Concentric neutral cable, 2 AWG Underground distribution cable, 2 AWG MV power cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 7\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.55\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 16\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e14 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 0.86 \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 637\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52215204741489,"sku":"NNCT2UDEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-30T130525.602.png?v=1763023708"},{"product_id":"1-awg-19-str-copper-primary-ud-cable-12-awg-full-neutral-epr-lldpe-mv-90-100-115-mil-8-kv","title":"1 AWG 19 Str Copper Primary UD Cable 12 AWG Full Neutral EPR \/ LLDPE MV-90 100% 115 mil 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_1.pdf?v=1743147152\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1 AWG 19 Str Copper Primary UD Cable 12 AWG Full Neutral EPR \/ LLDPE MV-90 100% 115 mil 8 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1 AWG Copper EPR cable, MV-90 UD cable, 1 AWG 5kV-46kV cable, Primary UD cable, Medium voltage cable, Concentric neutral cable, 1 AWG Underground distribution cable, 1 AWG MV power cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.59\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 13\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e12 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 0.93\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 782\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52215206052209,"sku":"NNCT1UDEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-30T130525.602.png?v=1763023708"},{"product_id":"1-0-awg-19-str-copper-primary-ud-cable-12-awg-full-neutral-epr-lldpe-mv-90-100-115-mil-8-kv","title":"1\/0 AWG 19 Str Copper Primary UD Cable 12 AWG Full Neutral EPR \/ LLDPE MV-90 100% 115 mil 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_1.pdf?v=1743147152\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1\/0 AWG 19 Str Copper Primary UD Cable 12 AWG Full Neutral EPR \/ LLDPE MV-90 100% 115 mil 8 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1\/0 AWG Copper EPR cable, MV-90 UD cable, 1\/0 AWG 5kV-46kV cable, Primary UD cable, Medium voltage cable, Concentric neutral cable, 1\/0 AWG Underground distribution cable, 1\/0 AWG MV power cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.63\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 16\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e12 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 0.97\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 926\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52215208313201,"sku":"NNCT1\/0UDEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-30T130525.602.png?v=1763023708"},{"product_id":"2-0-awg-19-str-copper-primary-ud-cable-10-awg-full-neutral-epr-lldpe-mv-90-100-115-mil-8-kv","title":"2\/0 AWG 19 Str Copper Primary UD Cable 10 AWG Full Neutral EPR \/ LLDPE MV-90 100% 115 mil 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_1.pdf?v=1743147152\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2\/0 AWG 19 Str Copper Primary UD Cable 10 AWG Full Neutral EPR \/ LLDPE MV-90 100% 115 mil 8 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e2\/0 AWG Copper EPR cable, MV-90 UD cable, 2\/0 AWG 5kV-46kV cable, Primary UD cable, Medium voltage cable, Concentric neutral cable, 2\/0 AWG Underground distribution cable, 2\/0 AWG MV power cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.68\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 13\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e10 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.06\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 1149\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52215209099633,"sku":"NNCT2\/0UDEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-30T130525.602.png?v=1763023708"},{"product_id":"3-0-awg-19-str-copper-primary-ud-cable-10-awg-full-neutral-epr-lldpe-mv-90-100-115-mil-8-kv","title":"3\/0 AWG 19 Str Copper Primary UD Cable 10 AWG Full Neutral EPR \/ LLDPE MV-90 100% 115 mil 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_1.pdf?v=1743147152\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e3\/0 AWG 19 Str Copper Primary UD Cable 10 AWG Full Neutral EPR \/ LLDPE MV-90 100% 115 mil 8 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e3\/0 AWG Copper EPR cable, MV-90 UD cable, 3\/0 AWG 5kV-46kV cable, Primary UD cable, Medium voltage cable, Concentric neutral cable, 3\/0 AWG Underground distribution cable, 3\/0 AWG MV power cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 3\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.73\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 16\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e10 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.11\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 1373\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52215210377585,"sku":"NNCT3\/0UDEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-30T130525.602.png?v=1763023708"},{"product_id":"4-0-awg-19-str-copper-primary-ud-cable-9-awg-full-neutral-epr-lldpe-mv-90-100-115-mil-8-kv","title":"4\/0 AWG 19 Str Copper Primary UD Cable 9 AWG Full Neutral EPR \/ LLDPE MV-90 100% 115 mil 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_1.pdf?v=1743147152\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e4\/0 AWG 19 Str Copper Primary UD Cable 9 AWG Full Neutral EPR \/ LLDPE MV-90 100% 115 mil 8 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e4\/0 AWG Copper EPR cable, MV-90 UD cable, 4\/0 AWG 5kV-46kV cable, Primary UD cable, Medium voltage cable, Concentric neutral cable, 4\/0 AWG Underground distribution cable, 4\/0 AWG MV power cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 4\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.78\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 16\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e9 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 1682\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52215210901873,"sku":"NNCT4\/0UDEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-30T130525.602.png?v=1763023708"},{"product_id":"250-mcm-37-str-copper-primary-ud-cable-10-awg-full-neutral-epr-lldpe-mv-90-100-115-mil-8-kv","title":"250 MCM 37 Str Copper Primary UD Cable 10 AWG Full Neutral EPR \/ LLDPE MV-90 100% 115 mil 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_1.pdf?v=1743147152\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e250 MCM 37 Str Copper Primary UD Cable 10 AWG Full Neutral EPR \/ LLDPE MV-90 100% 115 mil 8 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e250 MCM Copper EPR cable, MV-90 UD cable, 250 MCM 5kV-46kV cable, Primary UD cable, Medium voltage cable, Concentric neutral cable, 250 MCM Underground distribution cable, 250 MCM MV power cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 250 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 37\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.84\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 25\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e10 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.22\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 1957\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52215212507505,"sku":"NNCT250UDEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-30T130525.602.png?v=1763023708"},{"product_id":"350-mcm-37-str-copper-primary-ud-cable-8-awg-full-neutral-epr-lldpe-mv-90-100-115-mil-8-kv","title":"350 MCM 37 Str Copper Primary UD Cable 8 AWG Full Neutral EPR \/ LLDPE MV-90 100% 115 mil 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_1.pdf?v=1743147152\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e350 MCM 37 Str Copper Primary UD Cable 8 AWG Full Neutral EPR \/ LLDPE MV-90 100% 115 mil 8 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e350 MCM Copper EPR cable, MV-90 UD cable, 350 MCM 5kV-46kV cable, Primary UD cable, Medium voltage cable, Concentric neutral cable, 350 MCM Underground distribution cable, 350 MCM MV power cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 350 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 37\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 0.94\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 22\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e8 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.37\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 2667\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52215212933489,"sku":"NNCT350UDEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-30T130525.602.png?v=1763023708"},{"product_id":"500-mcm-37-str-copper-primary-ud-cable-8-awg-full-neutral-epr-lldpe-mv-90-100-115-mil-8-kv","title":"500 MCM 37 Str Copper Primary UD Cable 8 AWG Full Neutral EPR \/ LLDPE MV-90 100% 115 mil 8 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_1.pdf?v=1743147152\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e500 MCM 37 Str Copper Primary UD Cable 8 AWG Full Neutral EPR \/ LLDPE MV-90 100% 115 mil 8 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e500 MCM Copper EPR cable, MV-90 UD cable, 500 MCM 5kV-46kV cable, Primary UD cable, Medium voltage cable, Concentric neutral cable, 500 MCM Underground distribution cable, 500 MCM MV power cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor: \u003c\/strong\u003eSoft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 500 MCM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 37\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.07\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 31\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e8 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.53\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 3663\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52215214047601,"sku":"NNCT500UDEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-30T130525.602.png?v=1763023708"},{"product_id":"1-0-awg-19-str-copper-primary-ud-cable-14-awg-1-3-neutral-epr-lldpe-mv-90-100-345-mil-35-kv","title":"1\/0 AWG 19 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 345 mil 35 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_1.pdf?v=1743147152\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1\/0 AWG 19 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 345 mil 35 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1\/0 AWG Copper EPR cable, MV-90 UD cable, 1\/0 AWG 5kV-46kV cable, Primary UD cable, Medium voltage cable, Concentric neutral cable, 1\/0 AWG Underground distribution cable, 1\/0 AWG MV power cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003c\/strong\u003e Soft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.10\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 9\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e14 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.43\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 1166\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52226073854321,"sku":"NNCP1\/0UDEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-30T130525.602.png?v=1763023708"},{"product_id":"2-0-awg-19-str-copper-primary-ud-cable-14-awg-1-3-neutral-epr-lldpe-mv-90-100-345-mil-35-kv","title":"2\/0 AWG 19 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 345 mil 35 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_1.pdf?v=1743147152\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2\/0 AWG 19 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 345 mil 35 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e2\/0 AWG Copper EPR cable, MV-90 UD cable, 2\/0 AWG 5kV-46kV cable, Primary UD cable, Medium voltage cable, Concentric neutral cable, 2\/0 AWG Underground distribution cable, 2\/0 AWG MV power cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003c\/strong\u003e Soft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.15\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 11\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e14 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.47\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 1313\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52226104230257,"sku":"NNCP2\/0UDEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-30T130525.602.png?v=1763023708"},{"product_id":"3-0-awg-19-str-copper-primary-ud-cable-14-awg-1-3-neutral-epr-lldpe-mv-90-100-345-mil-35-kv","title":"3\/0 AWG 19 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 345 mil 35 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_1.pdf?v=1743147152\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e3\/0 AWG 19 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 345 mil 35 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e3\/0 AWG Copper EPR cable, MV-90 UD cable, 3\/0 AWG 5kV-46kV cable, Primary UD cable, Medium voltage cable, Concentric neutral cable, 3\/0 AWG Underground distribution cable, 3\/0 AWG MV power cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003c\/strong\u003e Soft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 3\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.20\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 14\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e14 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.52\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 1499\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52226105803121,"sku":"NNCP3\/0UDEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-30T130525.602.png?v=1763023708"},{"product_id":"4-0-awg-19-str-copper-primary-ud-cable-14-awg-1-3-neutral-epr-lldpe-mv-90-100-345-mil-35-kv","title":"4\/0 AWG 19 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 345 mil 35 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_1.pdf?v=1743147152\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e4\/0 AWG 19 Str Copper Primary UD Cable 14 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 345 mil 35 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e4\/0 AWG Copper EPR cable, MV-90 UD cable, 4\/0 AWG 5kV-46kV cable, Primary UD cable, Medium voltage cable, Concentric neutral cable, 4\/0 AWG Underground distribution cable, 4\/0 AWG MV power cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003c\/strong\u003e Soft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 4\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.25\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 18\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e14 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.58\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 1731 \u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52226112029041,"sku":"NNCP4\/0UDEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-30T130525.602_c6342ebb-9616-4ae5-93c6-4b2fa1710708.png?v=1763023884"},{"product_id":"250-mcm-37-str-copper-primary-ud-cable-12-awg-1-3-neutral-epr-lldpe-mv-90-100-345-mil-35-kv","title":"250 MCM 37 Str Copper Primary UD Cable 12 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 345 mil 35 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_1.pdf?v=1743147152\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e250 MCM 37 Str Copper Primary UD Cable 12 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 345 mil 35 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e250 MCM Copper EPR cable, MV-90 UD cable, 250 MCM 5kV-46kV cable, Primary UD cable, Medium voltage cable, Concentric neutral cable, 250 MCM Underground distribution cable, 250 MCM MV power cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003c\/strong\u003e Soft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 250 MCM \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 37\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.31\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 13\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e12 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 80\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.73\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 2032\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52226114257265,"sku":"NNCP250UDEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-30T130525.602_c6342ebb-9616-4ae5-93c6-4b2fa1710708.png?v=1763023884"},{"product_id":"350-mcm-37-str-copper-primary-ud-cable-12-awg-1-3-neutral-epr-lldpe-mv-90-100-345-mil-35-kv","title":"350 MCM 37 Str Copper Primary UD Cable 12 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 345 mil 35 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_1.pdf?v=1743147152\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e350 MCM 37 Str Copper Primary UD Cable 12 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 345 mil 35 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e350 MCM Copper EPR cable, MV-90 UD cable, 350 MCM 5kV-46kV cable, Primary UD cable, Medium voltage cable, Concentric neutral cable, 350 MCM Underground distribution cable, 350 MCM MV power cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003c\/strong\u003e Soft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 350 MCM \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 37\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.41\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 18\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e12 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 80\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.83\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 2531 \u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52226119041393,"sku":"NNCP350UDEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-30T130525.602_c6342ebb-9616-4ae5-93c6-4b2fa1710708.png?v=1763023884"},{"product_id":"500-mcm-37-str-copper-primary-ud-cable-10-awg-1-3-neutral-epr-lldpe-mv-90-100-345-mil-35-kv","title":"500 MCM 37 Str Copper Primary UD Cable 10 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 345 mil 35 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_1.pdf?v=1743147152\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e500 MCM 37 Str Copper Primary UD Cable 10 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 345 mil 35 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e500 MCM Copper EPR cable, MV-90 UD cable, 500 MCM 5kV-46kV cable, Primary UD cable, Medium voltage cable, Concentric neutral cable, 500 MCM Underground distribution cable, 500 MCM MV power cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003c\/strong\u003e Soft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 500 MCM \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 37\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.54\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 17\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e10 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 80\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 2.04\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 3388\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52226124743025,"sku":"NNCP500UDEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-30T130525.602_c6342ebb-9616-4ae5-93c6-4b2fa1710708.png?v=1763023884"},{"product_id":"750-mcm-61-str-copper-primary-ud-cable-9-awg-1-3-neutral-epr-lldpe-mv-90-100-345-mil-35-kv","title":"750 MCM 61 Str Copper Primary UD Cable 9 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 345 mil 35 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_1.pdf?v=1743147152\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e750 MCM 61 Str Copper Primary UD Cable 9 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 345 mil 35 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e750 MCM Copper EPR cable, MV-90 UD cable, 750 MCM 5kV-46kV cable, Primary UD cable, Medium voltage cable, Concentric neutral cable, 750 MCM Underground distribution cable, 750 MCM MV power cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003c\/strong\u003e Soft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 750 MCM \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 61\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.73\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 20\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e9 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 80\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 2.25\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 4630\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52226132214129,"sku":"NNCP750UDEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-30T130525.602_c6342ebb-9616-4ae5-93c6-4b2fa1710708.png?v=1763023884"},{"product_id":"1000-mcm-61-str-copper-primary-ud-cable-9-awg-1-3-neutral-epr-lldpe-mv-90-100-345-mil-35-kv","title":"1000 MCM 61 Str Copper Primary UD Cable 9 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 345 mil 35 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_1.pdf?v=1743147152\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1000 MCM 61 Str Copper Primary UD Cable 9 AWG 1\/3 Neutral EPR \/ LLDPE MV-90 100% 345 mil 35 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1000 MCM Copper EPR cable, MV-90 UD cable, 1000 MCM 5kV-46kV cable, Primary UD cable, Medium voltage cable, Concentric neutral cable, 1000 MCM Underground distribution cable, 1000 MCM MV power cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003c\/strong\u003e Soft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1000 MCM \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 61\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.88\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 26\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/3 Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e9 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 80\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 2.40\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 5779\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52226139685233,"sku":"NNCP1000UDEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-30T130525.602_c6342ebb-9616-4ae5-93c6-4b2fa1710708.png?v=1763023884"},{"product_id":"1-0-awg-19-str-copper-primary-ud-cable-12-awg-full-neutral-epr-lldpe-mv-90-100-345-mil-35-kv","title":"1\/0 AWG 19 Str Copper Primary UD Cable 12 AWG Full Neutral EPR \/ LLDPE MV-90 100% 345 mil 35 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/pud-03-epr-ldpe_1.pdf?v=1743147152\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1\/0 AWG 19 Str Copper Primary UD Cable 12 AWG Full Neutral EPR \/ LLDPE MV-90 100% 345 mil 35 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Underground primary residential and commercial distribution circuits.\u003cbr\u003e• May be used in wet or dry locations, installed in underground ducts or direct burial.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e1\/0 AWG Copper EPR cable, MV-90 UD cable, 1\/0 AWG 5kV-46kV cable, Primary UD cable, Medium voltage cable, Concentric neutral cable, 1\/0 AWG Underground distribution cable, 1\/0 AWG MV power cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• ICEA S-94-649:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard for Concentric Neutral Rated Cables 5 – 46 kV.\u003cstrong\u003e\u003cbr\u003e• AEIC CS8:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifications for Extruded Dielectric, Shielded Power Cable, rated 5 – 46 kV.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum operating voltage:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• 5 kV – 46 kV, 100 and 133% IL \u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum conductor operation temperatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWet and dry locations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Normal: 105 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Emergency: 140 °C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Short Circuit: 250 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Conductor:\u003c\/strong\u003e Soft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG - 1000 kcmil\u003cstrong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conductor Shield:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e\u003cstrong\u003e• Insulation:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eThermoset ethylene propylene rubber (EPR). On request: amorphous EPR, containing 0% PE and less than 72% Ethylene.\u003cbr\u003e\u003cstrong\u003e• Insulation Shield: \u003c\/strong\u003eSemi conducting cross-linked polyethylene (XLPE).\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConcentric Neutral:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSoft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1\/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.\u003cbr\u003e\u003cstrong\u003e• Jacket: \u003c\/strong\u003eExtruded to fill (Encapsulated) Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e• Low tension stripping compounds.\u003cbr\u003e• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.\u003cbr\u003e• On request, Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.\u003cbr\u003e• When requested, Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.\u003cbr\u003e• On request, Dual sealed cable (Strand Filled on conductor + WSP on Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.\u003cbr\u003e• On request, can be UL Listed as MV90 for use in accordance with Article 328 of the NEC.\u003cbr\u003e• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1\/0 AWG\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e\u003cspan\u003e 19\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Nominal OD Over Insulation (In):\u003c\/strong\u003e\u003cspan\u003e 1.10\u003cbr\u003e\u003cstrong\u003e• Number of Wires:\u003c\/strong\u003e 16\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Full Neutral Size:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e12 AWG\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 50\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter (In):\u003c\/strong\u003e\u003cspan\u003e 1.46\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight lb\/kft:\u003c\/strong\u003e\u003cspan\u003e 1395\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52226148827505,"sku":"NNCP1\/01UDEPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Untitled_design_-_2025-04-30T130525.602_c6342ebb-9616-4ae5-93c6-4b2fa1710708.png?v=1763023884"}],"url":"https:\/\/nassaunationalcable.com\/collections\/copper-epr-lldpe-concentric-neutral-mv-90-primary-ud-cable-5-kv-46-kv.oembed?page=10","provider":"NassauNationalCable","version":"1.0","type":"link"}