{"title":"Copper 3C MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV","description":"","products":[{"product_id":"8-awg-3c-copper-mv-90-non-shielded-epr-insulated-pvc-jacketed-2-4-kv","title":"8 AWG 3C Copper MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-03-mv90-epr-nonshd.pdf?v=1735793858\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e8 AWG 3C Copper MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Per NEC, use is limited to 2400 volts maximum.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e For use in power system in industrial establishments and utility applications, for dry\u003cbr\u003elocations, in accordance with NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e8 AWG 3C Copper MV-90 Cable, 8 AWG 3C  2.4kV Non-Shielded Cable, EPR Insulated PVC Cable, Medium Voltage 3C Copper, 2.4 kV EPR Cable, Non-Shielded PVC Jacketed Cable, 8 AWG 3C MV-90 Cable, Copper EPR Cable 2.4 kV, MV-90 3C PVC Cable, 8 AWG 3C 2.4 kV Copper Non-Shielded Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-96-659\/NEMA WC71\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Non shielded Cables Rated 2001-5000 Volts for Use in the Distribution of Electrical Energy.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated For CT use 1\/0 AWG and up.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Jacket is listed Sunlight Resistant and Oil Resistant I.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Jacket is flame retardant. \u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003eSizes: 8 AWG (6 AWG Aluminum) up to 1000 kcmil.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e  Semi conducting cross-linked polyethylene (XLPE). \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermoplastic polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 8 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 7\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.13\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (mil):\u003c\/strong\u003e 90\u003cbr\u003e\u003cstrong\u003e• Ground Conductor* per Interstice Copper AWG:\u003c\/strong\u003e 8\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 80\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 0.96\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 529\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52058465862001,"sku":"NNC08MV90EPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_f7d5dee3-14ba-4bad-a304-d305c9f6c42b.png?v=1759832197"},{"product_id":"6-awg-3c-copper-mv-90-non-shielded-epr-insulated-pvc-jacketed-2-4-kv","title":"6 AWG 3C Copper MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-03-mv90-epr-nonshd.pdf?v=1735793858\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e6 AWG 3C Copper MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Per NEC, use is limited to 2400 volts maximum.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e For use in power system in industrial establishments and utility applications, for dry\u003cbr\u003elocations, in accordance with NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e6 AWG 3C Copper MV-90 Cable, 6 AWG 3C  2.4kV Non-Shielded Cable, EPR Insulated PVC Cable, Medium Voltage 3C Copper, 2.4 kV EPR Cable, Non-Shielded PVC Jacketed Cable, 6 AWG 3C MV-90 Cable, Copper EPR Cable 2.4 kV, MV-90 3C PVC Cable, 6 AWG 3C 2.4 kV Copper Non-Shielded Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-96-659\/NEMA WC71\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Non shielded Cables Rated 2001-5000 Volts for Use in the Distribution of Electrical Energy.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated For CT use 1\/0 AWG and up.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Jacket is listed Sunlight Resistant and Oil Resistant I.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Jacket is flame retardant. \u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003eSizes: 8 AWG (6 AWG Aluminum) up to 1000 kcmil.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e  Semi conducting cross-linked polyethylene (XLPE). \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermoplastic polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 6 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 7\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.17\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (mil):\u003c\/strong\u003e 90\u003cbr\u003e\u003cstrong\u003e• Ground Conductor* per Interstice Copper AWG:\u003c\/strong\u003e 6\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 80\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 1.03\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 689\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52058467565937,"sku":"NNC06MV90EPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_39f25e3d-b83f-46c4-a2eb-ca72dbf5c6f4.png?v=1763020090"},{"product_id":"4-awg-3c-copper-mv-90-non-shielded-epr-insulated-pvc-jacketed-2-4-kv","title":"4 AWG 3C Copper MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-03-mv90-epr-nonshd.pdf?v=1735793858\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e4 AWG 3C Copper MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Per NEC, use is limited to 2400 volts maximum.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e For use in power system in industrial establishments and utility applications, for dry\u003cbr\u003elocations, in accordance with NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e4 AWG 3C Copper MV-90 Cable, 4 AWG 3C  2.4kV Non-Shielded Cable, EPR Insulated PVC Cable, Medium Voltage 3C Copper, 2.4 kV EPR Cable, Non-Shielded PVC Jacketed Cable, 4 AWG 3C MV-90 Cable, Copper EPR Cable 2.4 kV, MV-90 3C PVC Cable, 4 AWG 3C 2.4 kV Copper Non-Shielded Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-96-659\/NEMA WC71\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Non shielded Cables Rated 2001-5000 Volts for Use in the Distribution of Electrical Energy.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated For CT use 1\/0 AWG and up.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Jacket is listed Sunlight Resistant and Oil Resistant I.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Jacket is flame retardant. \u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003eSizes: 8 AWG (6 AWG Aluminum) up to 1000 kcmil.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e  Semi conducting cross-linked polyethylene (XLPE). \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermoplastic polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 4 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 7\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.21\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (mil):\u003c\/strong\u003e 90\u003cbr\u003e\u003cstrong\u003e• Ground Conductor* per Interstice Copper AWG:\u003c\/strong\u003e 6\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 80\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 1.13\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 891\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52058468024689,"sku":"NNC04MV90EPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_95e553d7-2068-47dc-a077-6660f62c25d7.png?v=1763020091"},{"product_id":"2-awg-3c-copper-mv-90-non-shielded-epr-insulated-pvc-jacketed-2-4-kv","title":"2 AWG 3C Copper MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-03-mv90-epr-nonshd.pdf?v=1735793858\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2 AWG 3C Copper MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Per NEC, use is limited to 2400 volts maximum.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e For use in power system in industrial establishments and utility applications, for dry\u003cbr\u003elocations, in accordance with NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e2 AWG 3C Copper MV-90 Cable, 2 AWG 3C  2.4kV Non-Shielded Cable, EPR Insulated PVC Cable, Medium Voltage 3C Copper, 2.4 kV EPR Cable, Non-Shielded PVC Jacketed Cable, 2 AWG 3C MV-90 Cable, Copper EPR Cable 2.4 kV, MV-90 3C PVC Cable, 2 AWG 3C 2.4 kV Copper Non-Shielded Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-96-659\/NEMA WC71\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Non shielded Cables Rated 2001-5000 Volts for Use in the Distribution of Electrical Energy.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated For CT use 1\/0 AWG and up.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Jacket is listed Sunlight Resistant and Oil Resistant I.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Jacket is flame retardant. \u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003eSizes: 8 AWG (6 AWG Aluminum) up to 1000 kcmil.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e  Semi conducting cross-linked polyethylene (XLPE). \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermoplastic polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 7\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.27\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (mil):\u003c\/strong\u003e 90\u003cbr\u003e\u003cstrong\u003e• Ground Conductor* per Interstice Copper AWG:\u003c\/strong\u003e 6\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 80\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 1.25\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 1196\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52058470678897,"sku":"NNC02MV90EPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_22ea0290-22b9-4210-bd4b-be90e93bd2f9.png?v=1763020094"},{"product_id":"1-awg-3c-copper-mv-90-non-shielded-epr-insulated-pvc-jacketed-2-4-kv","title":"1 AWG 3C Copper MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-03-mv90-epr-nonshd.pdf?v=1735793858\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1 AWG 3C Copper MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Per NEC, use is limited to 2400 volts maximum.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e For use in power system in industrial establishments and utility applications, for dry\u003cbr\u003elocations, in accordance with NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e1 AWG 3C Copper MV-90 Cable, 1 AWG 3C  2.4kV Non-Shielded Cable, EPR Insulated PVC Cable, Medium Voltage 3C Copper, 2.4 kV EPR Cable, Non-Shielded PVC Jacketed Cable, 1 AWG 3C MV-90 Cable, Copper EPR Cable 2.4 kV, MV-90 3C PVC Cable, 1 AWG 3C 2.4 kV Copper Non-Shielded Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-96-659\/NEMA WC71\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Non shielded Cables Rated 2001-5000 Volts for Use in the Distribution of Electrical Energy.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated For CT use 1\/0 AWG and up.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Jacket is listed Sunlight Resistant and Oil Resistant I.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Jacket is flame retardant. \u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003eSizes: 8 AWG (6 AWG Aluminum) up to 1000 kcmil.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e  Semi conducting cross-linked polyethylene (XLPE). \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermoplastic polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.30\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (mil):\u003c\/strong\u003e 90\u003cbr\u003e\u003cstrong\u003e• Ground Conductor* per Interstice Copper AWG:\u003c\/strong\u003e 4\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 80\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 1.31\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 1438\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52058471006577,"sku":"NNC01MV90EPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_9ed1c2bd-2a54-4467-a24f-e99d70576b72.png?v=1759832197"},{"product_id":"1-0-awg-3c-copper-mv-90-non-shielded-epr-insulated-pvc-jacketed-2-4-kv","title":"1\/0 AWG 3C Copper MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-03-mv90-epr-nonshd.pdf?v=1735793858\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1\/0 AWG 3C Copper MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Per NEC, use is limited to 2400 volts maximum.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e For use in power system in industrial establishments and utility applications, for dry\u003cbr\u003elocations, in accordance with NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e1\/0 AWG 3C Copper MV-90 Cable, 1\/0 AWG 3C  2.4kV Non-Shielded Cable, EPR Insulated PVC Cable, Medium Voltage 3C Copper, 2.4 kV EPR Cable, Non-Shielded PVC Jacketed Cable, 1\/0 AWG 3C MV-90 Cable, Copper EPR Cable 2.4 kV, MV-90 3C PVC Cable, 1\/0 AWG 3C 2.4 kV Copper Non-Shielded Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-96-659\/NEMA WC71\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Non shielded Cables Rated 2001-5000 Volts for Use in the Distribution of Electrical Energy.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated For CT use 1\/0 AWG and up.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Jacket is listed Sunlight Resistant and Oil Resistant I.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Jacket is flame retardant. \u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003eSizes: 8 AWG (6 AWG Aluminum) up to 1000 kcmil.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e  Semi conducting cross-linked polyethylene (XLPE). \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermoplastic polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1\/0 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.34\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (mil):\u003c\/strong\u003e 90\u003cbr\u003e\u003cstrong\u003e• Ground Conductor* per Interstice Copper AWG:\u003c\/strong\u003e 4\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 80\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 1.39\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 1695 \u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52058473726321,"sku":"NNC10MV90EPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_74f58800-fd7d-4c67-9092-6159b1a0d327.png?v=1759832198"},{"product_id":"2-0-awg-3c-copper-mv-90-non-shielded-epr-insulated-pvc-jacketed-2-4-kv","title":"2\/0 AWG 3C Copper MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-03-mv90-epr-nonshd.pdf?v=1735793858\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e2\/0 AWG 3C Copper MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Per NEC, use is limited to 2400 volts maximum.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e For use in power system in industrial establishments and utility applications, for dry\u003cbr\u003elocations, in accordance with NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e2\/0 AWG 3C Copper MV-90 Cable, 2\/0 AWG 3C  2.4kV Non-Shielded Cable, EPR Insulated PVC Cable, Medium Voltage 3C Copper, 2.4 kV EPR Cable, Non-Shielded PVC Jacketed Cable, 2\/0 AWG 3C MV-90 Cable, Copper EPR Cable 2.4 kV, MV-90 3C PVC Cable, 2\/0 AWG 3C 2.4 kV Copper Non-Shielded Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-96-659\/NEMA WC71\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Non shielded Cables Rated 2001-5000 Volts for Use in the Distribution of Electrical Energy.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated For CT use 1\/0 AWG and up.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Jacket is listed Sunlight Resistant and Oil Resistant I.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Jacket is flame retardant. \u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003eSizes: 8 AWG (6 AWG Aluminum) up to 1000 kcmil.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e  Semi conducting cross-linked polyethylene (XLPE). \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermoplastic polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 2\/0 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.38\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (mil):\u003c\/strong\u003e 90\u003cbr\u003e\u003cstrong\u003e• Ground Conductor* per Interstice Copper AWG:\u003c\/strong\u003e 4\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 80\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 1.48\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 2011\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52058474021233,"sku":"NNC20MV90EPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_29fdc105-bcf9-4a48-bf9f-e78c23645a63.png?v=1763020098"},{"product_id":"3-0-awg-3c-copper-mv-90-non-shielded-epr-insulated-pvc-jacketed-2-4-kv","title":"3\/0 AWG 3C Copper MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-03-mv90-epr-nonshd.pdf?v=1735793858\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e3\/0 AWG 3C Copper MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Per NEC, use is limited to 2400 volts maximum.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e For use in power system in industrial establishments and utility applications, for dry\u003cbr\u003elocations, in accordance with NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e3\/0 AWG 3C Copper MV-90 Cable, 3\/0 AWG 3C  2.4kV Non-Shielded Cable, EPR Insulated PVC Cable, Medium Voltage 3C Copper, 2.4 kV EPR Cable, Non-Shielded PVC Jacketed Cable, 3\/0 AWG 3C MV-90 Cable, Copper EPR Cable 2.4 kV, MV-90 3C PVC Cable, 3\/0 AWG 3C 2.4 kV Copper Non-Shielded Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-96-659\/NEMA WC71\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Non shielded Cables Rated 2001-5000 Volts for Use in the Distribution of Electrical Energy.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated For CT use 1\/0 AWG and up.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Jacket is listed Sunlight Resistant and Oil Resistant I.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Jacket is flame retardant. \u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003eSizes: 8 AWG (6 AWG Aluminum) up to 1000 kcmil.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e  Semi conducting cross-linked polyethylene (XLPE). \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermoplastic polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 3\/0 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.42\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (mil):\u003c\/strong\u003e 90\u003cbr\u003e\u003cstrong\u003e• Ground Conductor* per Interstice Copper AWG:\u003c\/strong\u003e 3\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 80\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 1.58\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 2436\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52058475495793,"sku":"NNC30MV90EPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_5f652fad-737f-49b4-9761-447ac4ae115f.png?v=1759832199"},{"product_id":"4-0-awg-3c-copper-mv-90-non-shielded-epr-insulated-pvc-jacketed-2-4-kv","title":"4\/0 AWG 3C Copper MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-03-mv90-epr-nonshd.pdf?v=1735793858\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e4\/0 AWG 3C Copper MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Per NEC, use is limited to 2400 volts maximum.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e For use in power system in industrial establishments and utility applications, for dry\u003cbr\u003elocations, in accordance with NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e4\/0 AWG 3C Copper MV-90 Cable, 4\/0 AWG 3C  2.4kV Non-Shielded Cable, EPR Insulated PVC Cable, Medium Voltage 3C Copper, 2.4 kV EPR Cable, Non-Shielded PVC Jacketed Cable, 4\/0 AWG 3C MV-90 Cable, Copper EPR Cable 2.4 kV, MV-90 3C PVC Cable, 4\/0 AWG 3C 2.4 kV Copper Non-Shielded Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-96-659\/NEMA WC71\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Non shielded Cables Rated 2001-5000 Volts for Use in the Distribution of Electrical Energy.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated For CT use 1\/0 AWG and up.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Jacket is listed Sunlight Resistant and Oil Resistant I.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Jacket is flame retardant. \u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003eSizes: 8 AWG (6 AWG Aluminum) up to 1000 kcmil.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e  Semi conducting cross-linked polyethylene (XLPE). \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermoplastic polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 4\/0 AWG\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 19\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.48\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (mil):\u003c\/strong\u003e 90\u003cbr\u003e\u003cstrong\u003e• Ground Conductor* per Interstice Copper AWG:\u003c\/strong\u003e 3\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 1.76\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 3032\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52058478379377,"sku":"NNC40MV90EPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_61e3030b-1d7c-41ad-ac36-d0df6a744768.png?v=1759832200"},{"product_id":"250-mcm-3c-copper-mv-90-non-shielded-epr-insulated-pvc-jacketed-2-4-kv","title":"250 MCM 3C Copper MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-03-mv90-epr-nonshd.pdf?v=1735793858\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e250 MCM 3C Copper MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Per NEC, use is limited to 2400 volts maximum.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e For use in power system in industrial establishments and utility applications, for dry\u003cbr\u003elocations, in accordance with NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e250 MCM 3C Copper MV-90 Cable, 250 MCM 3C 2.4kV Non-Shielded Cable, EPR Insulated PVC Cable, Medium Voltage 3C Copper, 2.4 kV EPR Cable, Non-Shielded PVC Jacketed Cable, 250 MCM 3C MV-90 Cable, Copper EPR Cable 2.4 kV, MV-90 3C PVC Cable, 250 MCM 3C 2.4 kV Copper Non-Shielded Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-96-659\/NEMA WC71\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Non shielded Cables Rated 2001-5000 Volts for Use in the Distribution of Electrical Energy.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated For CT use 1\/0 AWG and up.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Jacket is listed Sunlight Resistant and Oil Resistant I.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Jacket is flame retardant. \u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003eSizes: 8 AWG (6 AWG Aluminum) up to 1000 kcmil.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e  Semi conducting cross-linked polyethylene (XLPE). \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermoplastic polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 250 MCM\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 37\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.52\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (mil):\u003c\/strong\u003e 90\u003cbr\u003e\u003cstrong\u003e• Ground Conductor* per Interstice Copper AWG:\u003c\/strong\u003e 2\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 1.88\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 3521\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52058480673137,"sku":"NNC250MV90EPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_0ee73ef0-d9cf-43f2-95ce-5521673f6c6f.png?v=1763020104"},{"product_id":"300-mcm-3c-copper-mv-90-non-shielded-epr-insulated-pvc-jacketed-2-4-kv","title":"300 MCM 3C Copper MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-03-mv90-epr-nonshd.pdf?v=1735793858\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e300 MCM 3C Copper MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Per NEC, use is limited to 2400 volts maximum.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e For use in power system in industrial establishments and utility applications, for dry\u003cbr\u003elocations, in accordance with NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e300 MCM 3C Copper MV-90 Cable, 300 MCM 3C 2.4kV Non-Shielded Cable, EPR Insulated PVC Cable, Medium Voltage 3C Copper, 2.4 kV EPR Cable, Non-Shielded PVC Jacketed Cable, 300 MCM 3C MV-90 Cable, Copper EPR Cable 2.4 kV, MV-90 3C PVC Cable, 300 MCM 3C 2.4 kV Copper Non-Shielded Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-96-659\/NEMA WC71\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Non shielded Cables Rated 2001-5000 Volts for Use in the Distribution of Electrical Energy.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated For CT use 1\/0 AWG and up.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Jacket is listed Sunlight Resistant and Oil Resistant I.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Jacket is flame retardant. \u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003eSizes: 8 AWG (6 AWG Aluminum) up to 1000 kcmil.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e  Semi conducting cross-linked polyethylene (XLPE). \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermoplastic polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 300 MCM\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 37\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.57\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (mil):\u003c\/strong\u003e 90\u003cbr\u003e\u003cstrong\u003e• Ground Conductor* per Interstice Copper AWG:\u003c\/strong\u003e 2\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 1.99\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 4073 \u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52058482835825,"sku":"NNC300MV90EPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_ab93f9e3-4b48-472c-9af1-e7a5fe87a826.png?v=1763020105"},{"product_id":"350-mcm-3c-copper-mv-90-non-shielded-epr-insulated-pvc-jacketed-2-4-kv","title":"350 MCM 3C Copper MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-03-mv90-epr-nonshd.pdf?v=1735793858\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e350 MCM 3C Copper MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Per NEC, use is limited to 2400 volts maximum.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e For use in power system in industrial establishments and utility applications, for dry\u003cbr\u003elocations, in accordance with NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e350 MCM 3C Copper MV-90 Cable, 350 MCM 3C 2.4kV Non-Shielded Cable, EPR Insulated PVC Cable, Medium Voltage 3C Copper, 2.4 kV EPR Cable, Non-Shielded PVC Jacketed Cable, 350 MCM 3C MV-90 Cable, Copper EPR Cable 2.4 kV, MV-90 3C PVC Cable, 350 MCM 3C 2.4 kV Copper Non-Shielded Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-96-659\/NEMA WC71\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Non shielded Cables Rated 2001-5000 Volts for Use in the Distribution of Electrical Energy.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated For CT use 1\/0 AWG and up.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Jacket is listed Sunlight Resistant and Oil Resistant I.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Jacket is flame retardant. \u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003eSizes: 8 AWG (6 AWG Aluminum) up to 1000 kcmil.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e  Semi conducting cross-linked polyethylene (XLPE). \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermoplastic polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 350 MCM\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 37\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.62\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (mil):\u003c\/strong\u003e 90\u003cbr\u003e\u003cstrong\u003e• Ground Conductor* per Interstice Copper AWG:\u003c\/strong\u003e 2\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 2.08\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 4630 \u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52058483884401,"sku":"NNC350MV90EPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_45789078-327f-4a06-8b30-75b8a9cb3f29.png?v=1763020107"},{"product_id":"400-mcm-3c-copper-mv-90-non-shielded-epr-insulated-pvc-jacketed-2-4-kv","title":"400 MCM 3C Copper MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-03-mv90-epr-nonshd.pdf?v=1735793858\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e400 MCM 3C Copper MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Per NEC, use is limited to 2400 volts maximum.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e For use in power system in industrial establishments and utility applications, for dry\u003cbr\u003elocations, in accordance with NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e400 MCM 3C Copper MV-90 Cable, 400 MCM 3C 2.4kV Non-Shielded Cable, EPR Insulated PVC Cable, Medium Voltage 3C Copper, 2.4 kV EPR Cable, Non-Shielded PVC Jacketed Cable, 400 MCM 3C MV-90 Cable, Copper EPR Cable 2.4 kV, MV-90 3C PVC Cable, 400 MCM 3C 2.4 kV Copper Non-Shielded Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-96-659\/NEMA WC71\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Non shielded Cables Rated 2001-5000 Volts for Use in the Distribution of Electrical Energy.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated For CT use 1\/0 AWG and up.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Jacket is listed Sunlight Resistant and Oil Resistant I.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Jacket is flame retardant. \u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003eSizes: 8 AWG (6 AWG Aluminum) up to 1000 kcmil.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e  Semi conducting cross-linked polyethylene (XLPE). \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermoplastic polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 400 MCM\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 37\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.66\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (mil):\u003c\/strong\u003e 90\u003cbr\u003e\u003cstrong\u003e• Ground Conductor* per Interstice Copper AWG:\u003c\/strong\u003e 1 \u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 2.18\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 5221\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52058485588337,"sku":"NNC400MV90EPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_85b1e08e-5076-434e-9485-747bffb17138.png?v=1763020109"},{"product_id":"500-mcm-3c-copper-mv-90-non-shielded-epr-insulated-pvc-jacketed-2-4-kv","title":"500 MCM 3C Copper MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-03-mv90-epr-nonshd.pdf?v=1735793858\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e500 MCM 3C Copper MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Per NEC, use is limited to 2400 volts maximum.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e For use in power system in industrial establishments and utility applications, for dry\u003cbr\u003elocations, in accordance with NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e500 MCM 3C Copper MV-90 Cable, 500 MCM 3C 2.4kV Non-Shielded Cable, EPR Insulated PVC Cable, Medium Voltage 3C Copper, 2.4 kV EPR Cable, Non-Shielded PVC Jacketed Cable, 500 MCM 3C MV-90 Cable, Copper EPR Cable 2.4 kV, MV-90 3C PVC Cable, 500 MCM 3C 2.4 kV Copper Non-Shielded Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-96-659\/NEMA WC71\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Non shielded Cables Rated 2001-5000 Volts for Use in the Distribution of Electrical Energy.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated For CT use 1\/0 AWG and up.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Jacket is listed Sunlight Resistant and Oil Resistant I.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Jacket is flame retardant. \u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003eSizes: 8 AWG (6 AWG Aluminum) up to 1000 kcmil.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e  Semi conducting cross-linked polyethylene (XLPE). \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermoplastic polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 500 MCM\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 37\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.74\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (mil):\u003c\/strong\u003e 90\u003cbr\u003e\u003cstrong\u003e• Ground Conductor* per Interstice Copper AWG:\u003c\/strong\u003e 1 \u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 2.34\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 6306 \u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52058486047089,"sku":"NNC500MV90EPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_d6eeb583-8fa8-4009-8a9b-104882579267.png?v=1763020110"},{"product_id":"600-mcm-3c-copper-mv-90-non-shielded-epr-insulated-pvc-jacketed-2-4-kv","title":"600 MCM 3C Copper MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-03-mv90-epr-nonshd.pdf?v=1735793858\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e600 MCM 3C Copper MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Per NEC, use is limited to 2400 volts maximum.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e For use in power system in industrial establishments and utility applications, for dry\u003cbr\u003elocations, in accordance with NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e600 MCM 3C Copper MV-90 Cable, 600 MCM 3C 2.4kV Non-Shielded Cable, EPR Insulated PVC Cable, Medium Voltage 3C Copper, 2.4 kV EPR Cable, Non-Shielded PVC Jacketed Cable, 600 MCM 3C MV-90 Cable, Copper EPR Cable 2.4 kV, MV-90 3C PVC Cable, 600 MCM 3C 2.4 kV Copper Non-Shielded Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-96-659\/NEMA WC71\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Non shielded Cables Rated 2001-5000 Volts for Use in the Distribution of Electrical Energy.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated For CT use 1\/0 AWG and up.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Jacket is listed Sunlight Resistant and Oil Resistant I.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Jacket is flame retardant. \u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003eSizes: 8 AWG (6 AWG Aluminum) up to 1000 kcmil.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e  Semi conducting cross-linked polyethylene (XLPE). \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermoplastic polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 600 MCM\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 61\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.81\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (mil):\u003c\/strong\u003e 90\u003cbr\u003e\u003cstrong\u003e• Ground Conductor* per Interstice Copper AWG:\u003c\/strong\u003e 1\/0\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 110\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 2.53 \u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 7414  \u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52058486636913,"sku":"NNC600MV90EPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_738ea0c2-f839-411f-a2f5-1fb96bec0203.png?v=1763020113"},{"product_id":"750-mcm-3c-copper-mv-90-non-shielded-epr-insulated-pvc-jacketed-2-4-kv","title":"750 MCM 3C Copper MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-03-mv90-epr-nonshd.pdf?v=1735793858\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e750 MCM 3C Copper MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Per NEC, use is limited to 2400 volts maximum.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e For use in power system in industrial establishments and utility applications, for dry\u003cbr\u003elocations, in accordance with NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e750 MCM 3C Copper MV-90 Cable, 750 MCM 3C 2.4kV Non-Shielded Cable, EPR Insulated PVC Cable, Medium Voltage 3C Copper, 2.4 kV EPR Cable, Non-Shielded PVC Jacketed Cable, 750 MCM 3C MV-90 Cable, Copper EPR Cable 2.4 kV, MV-90 3C PVC Cable, 750 MCM 3C 2.4 kV Copper Non-Shielded Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-96-659\/NEMA WC71\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Non shielded Cables Rated 2001-5000 Volts for Use in the Distribution of Electrical Energy.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated For CT use 1\/0 AWG and up.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Jacket is listed Sunlight Resistant and Oil Resistant I.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Jacket is flame retardant. \u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003eSizes: 8 AWG (6 AWG Aluminum) up to 1000 kcmil.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e  Semi conducting cross-linked polyethylene (XLPE). \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermoplastic polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 750 MCM\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 61\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 0.91 \u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (mil):\u003c\/strong\u003e 90\u003cbr\u003e\u003cstrong\u003e• Ground Conductor* per Interstice Copper AWG:\u003c\/strong\u003e 1\/0\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 140\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 2.80\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 9168\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52058488373617,"sku":"NNC750MV90EPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_064eb3ee-8e3f-4249-93c2-9501aac7013e.png?v=1759832200"},{"product_id":"1000-mcm-3c-copper-mv-90-non-shielded-epr-insulated-pvc-jacketed-2-4-kv","title":"1000 MCM 3C Copper MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/mvm-03-mv90-epr-nonshd.pdf?v=1735793858\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003cspan data-sheets-root=\"1\"\u003e1000 MCM 3C Copper MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e Per NEC, use is limited to 2400 volts maximum.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e For use in power system in industrial establishments and utility applications, for dry\u003cbr\u003elocations, in accordance with NEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e1000 MCM 3C Copper MV-90 Cable, 1000 MCM 3C 2.4kV Non-Shielded Cable, EPR Insulated PVC Cable, Medium Voltage 3C Copper, 2.4 kV EPR Cable, Non-Shielded PVC Jacketed Cable, 1000 MCM 3C MV-90 Cable, Copper EPR Cable 2.4 kV, MV-90 3C PVC Cable, 1000MCM 3C 2.4 kV Copper Non-Shielded Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL 1072\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Medium Voltage Power Cables.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e ICEA S-96-659\/NEMA WC71\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Standard for Non shielded Cables Rated 2001-5000 Volts for Use in the Distribution of Electrical Energy.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e UL Listed as MV-90.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Rated For CT use 1\/0 AWG and up.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Jacket is listed Sunlight Resistant and Oil Resistant I.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e Jacket is flame retardant. \u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e•\u003c\/strong\u003e\u003cspan\u003e \u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.\u003cbr\u003eSizes: 8 AWG (6 AWG Aluminum) up to 1000 kcmil.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eConductor Shield:\u003c\/strong\u003e  Semi conducting cross-linked polyethylene (XLPE). \u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eInsulation:\u003c\/strong\u003e Thermoset ethylene propylene rubber (EPR).\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eGrounding (Optional):\u003c\/strong\u003e One or three soft annealed bare copper conductors cabled with phase conductors.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eAssembly:\u003c\/strong\u003e Conductors cabled with non-hygroscopic fillers, as required and binder tape.\u003cbr\u003e\u003cstrong\u003e•\u003c\/strong\u003e \u003cstrong\u003eJacket:\u003c\/strong\u003e Black sunlight resistance and flame retardant thermoplastic polyvinyl chloride (PVC) compound.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e• Size:\u003c\/strong\u003e\u003cspan\u003e 1000 MCM\u003cbr\u003e\u003cstrong\u003e• Number of Strands:\u003c\/strong\u003e 61\u003cbr\u003e\u003cstrong\u003e• Conductor Diameter (In):\u003c\/strong\u003e 1.06\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness (mil):\u003c\/strong\u003e 90\u003cbr\u003e\u003cstrong\u003e• Ground Conductor* per Interstice Copper AWG:\u003c\/strong\u003e 2\/0\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness (mil):\u003c\/strong\u003e 140\u003cbr\u003e\u003cstrong\u003e• Approximate Outside Diameter:\u003c\/strong\u003e 3.13\u003cbr\u003e\u003cstrong\u003e• Approximate Net Weight Copper lb\/kft:\u003c\/strong\u003e 11905\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":52058488668529,"sku":"NNC1000MV90EPR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/1_396ab66e-9638-46d1-ab3f-11831bf052f8.png?v=1763020117"}],"url":"https:\/\/nassaunationalcable.com\/collections\/copper-3c-mv-90-non-shielded-epr-insulated-pvc-jacketed-2-4-kv.oembed","provider":"NassauNationalCable","version":"1.0","type":"link"}