{"title":"C-L-X TYPE P-OS, TYPE ITC\/PLTC, ARMORED, SINGLE PAIR OR TRIAD - 105 DEG. C","description":"","products":[{"product_id":"564-10-3401-c-l-x-type-p-os-type-itc-pltc-armored-single-pair-16-awg-105-deg-c","title":"564-10-3401 C-L-X Type P-OS, Type ITC\/PLTC, Armored, Single Pair - 16 AWG - 105 Deg. C","description":"[short]\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductors:\u003c\/strong\u003e Bare soft annealed copper, Class B, 7-strand concentric per ASTM B-8.\u003cbr\u003e \u003cstrong\u003eInsulation: \u003c\/strong\u003eFlame-retardant Okoseal® (PVC) per UL 13 and UL 2250, 15 mils nominal thickness, 105°C temperature rating. \u003cbr\u003e \u003cstrong\u003eColor Identification: \u003c\/strong\u003ePigmented black and white in pairs, black, red and white in triads. \u003cbr\u003e \u003cstrong\u003eAsembly: \u003c\/strong\u003ePair or triad assembled with left-hand lay.\u003cbr\u003e \u003cstrong\u003eCable Shield: \u003c\/strong\u003eAluminum\/synthetic polymer tape overlapped to provide 100% coverage, and a 7-strand tinned copper drain wire, same size as conductor.\u003cbr\u003e \u003cstrong\u003eJacket: \u003c\/strong\u003eBlack, flame-retardant, low temperature Okoseal per UL 13 and UL 2250. A rip cord is laid longitudinally under the jacket to facilitate removal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eClassifications\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e UL Listed as Type ITC\/PLTC — Instrumentation Tray Cable\/Power Limited Tray Cable for use in accordance with Article 727 and Article 725 of the National Electrical Code.\u003cbr\u003e These cables comply with UL 2250 and UL 13 for PLTC, CL2 and CL3.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e Okonite type P-OS (Pair\/Triad - Overall Shield) instrumentation cables are designed for use as instrumentation, process control, and computer cables in ITC non-classified or labeled circuits up to 150 volts and 5 amps (750VA) and in Class 2 or 3 Power-Limited circuits where shielding against external interference is required, but shielding against interference among groups is not required; indoors or outdoors; in wet or dry locations with conductor operating temperatures up to 105°C; in cable trays; in raceways; supported by a messenger wire. Suitable Class I, Division 2, Class II, Division 2, or Class III, Division 2 hazardous locations. Also for use as Power-Limited fire protective signaling cable (FPL) per NEC Code 760.\u003cbr\u003e The overall shield eliminates most of the static interference from the electric field radiated by power cables and other electrical equipment.\u003cbr\u003e For dc service in wet locations, X-Olene® insulation is recommended.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePasses the UL 1581 \u0026amp; IEEE 383-1974 vertical tray flame tests.\u003c\/li\u003e\n\u003cli\u003eSunlight resistant and oil resistant.\u003c\/li\u003e\n\u003cli\u003eIndividual pairs or triads are color coded for simplified hook-up.\u003c\/li\u003e\n\u003cli\u003eGood noise rejection.\u003c\/li\u003e\n\u003cli\u003eExcellent weathering characteristics.\u003c\/li\u003e\n\u003cli\u003eOSHA Acceptable.\u003c\/li\u003e\n\u003cli\u003eFlexible, easy to handle and terminate.\u003c\/li\u003e\n\u003cli\u003eTwisted with 100% shield coverage to reduce electromagnetic noise pick-up.\u003c\/li\u003e\n\u003cli\u003eSuitable for low temperature installation of -40°C.\u003c\/li\u003e\n\u003c\/ul\u003e\n[\/short]","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27552917553252,"sku":"NNC8353X","price":3.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/clx-pos-single-105_2.jpg?v=1762461827"},{"product_id":"564-15-3401-c-l-x-type-p-os-type-itc-pltc-armored-single-triad-16-awg-105-deg-c","title":"564-15-3401 C-L-X Type P-OS, Type ITC\/PLTC, Armored, Single Triad - 16 AWG - 105 Deg. C","description":"[short]\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductors:\u003c\/strong\u003e Bare soft annealed copper, Class B, 7-strand concentric per ASTM B-8.\u003cbr\u003e \u003cstrong\u003eInsulation: \u003c\/strong\u003eFlame-retardant Okoseal® (PVC) per UL 13 and UL 2250, 15 mils nominal thickness, 105°C temperature rating. \u003cbr\u003e \u003cstrong\u003eColor Identification: \u003c\/strong\u003ePigmented black and white in pairs, black, red and white in triads. \u003cbr\u003e \u003cstrong\u003eAsembly: \u003c\/strong\u003ePair or triad assembled with left-hand lay.\u003cbr\u003e \u003cstrong\u003eCable Shield: \u003c\/strong\u003eAluminum\/synthetic polymer tape overlapped to provide 100% coverage, and a 7-strand tinned copper drain wire, same size as conductor.\u003cbr\u003e \u003cstrong\u003eJacket: \u003c\/strong\u003eBlack, flame-retardant, low temperature Okoseal per UL 13 and UL 2250. A rip cord is laid longitudinally under the jacket to facilitate removal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eClassifications\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e UL Listed as Type ITC\/PLTC — Instrumentation Tray Cable\/Power Limited Tray Cable for use in accordance with Article 727 and Article 725 of the National Electrical Code.\u003cbr\u003e These cables comply with UL 2250 and UL 13 for PLTC, CL2 and CL3.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e Okonite type P-OS (Pair\/Triad - Overall Shield) instrumentation cables are designed for use as instrumentation, process control, and computer cables in ITC non-classified or labeled circuits up to 150 volts and 5 amps (750VA) and in Class 2 or 3 Power-Limited circuits where shielding against external interference is required, but shielding against interference among groups is not required; indoors or outdoors; in wet or dry locations with conductor operating temperatures up to 105°C; in cable trays; in raceways; supported by a messenger wire. Suitable Class I, Division 2, Class II, Division 2, or Class III, Division 2 hazardous locations. Also for use as Power-Limited fire protective signaling cable (FPL) per NEC Code 760.\u003cbr\u003e The overall shield eliminates most of the static interference from the electric field radiated by power cables and other electrical equipment.\u003cbr\u003e For dc service in wet locations, X-Olene® insulation is recommended.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePasses the UL 1581 \u0026amp; IEEE 383-1974 vertical tray flame tests.\u003c\/li\u003e\n\u003cli\u003eSunlight resistant and oil resistant.\u003c\/li\u003e\n\u003cli\u003eIndividual pairs or triads are color coded for simplified hook-up.\u003c\/li\u003e\n\u003cli\u003eGood noise rejection.\u003c\/li\u003e\n\u003cli\u003eExcellent weathering characteristics.\u003c\/li\u003e\n\u003cli\u003eOSHA Acceptable.\u003c\/li\u003e\n\u003cli\u003eFlexible, easy to handle and terminate.\u003c\/li\u003e\n\u003cli\u003eTwisted with 100% shield coverage to reduce electromagnetic noise pick-up.\u003c\/li\u003e\n\u003cli\u003eSuitable for low temperature installation of -40°C.\u003c\/li\u003e\n\u003c\/ul\u003e\n[\/short]","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27552917618788,"sku":"NNC8354X","price":3.58,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/clx-pos-single-105_2_ebc196ef-a3aa-4946-af93-5e9a58fb61d0.jpg?v=1762461828"}],"url":"https:\/\/nassaunationalcable.com\/collections\/c-l-x-type-p-os-type-itc-pltc-armored-single-pair-or-triad-105-deg-c.oembed","provider":"NassauNationalCable","version":"1.0","type":"link"}