{"title":"Aluminum XLP USE-2 RHH\/RHW-2 Direct Burial Building Wire","description":"","products":[{"product_id":"6-awg-aluminum-xlp-use-2-rhh-rhw-2-direct-burial-building-wire","title":"6 AWG Aluminum XLP USE-2 RHH\/RHW-2 Direct Burial Building Wire","description":"\u003cp\u003e[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/AL_XLP.pdf?v=1724417087\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch2\u003e6 AWG Aluminum XLP USE-2 RHH\/RHW-2 Direct Burial Building Wire\u003c\/h2\u003e\n\u003cp data-start=\"205\" data-end=\"291\"\u003e\u003cstrong data-start=\"205\" data-end=\"289\"\u003eAllowable Ampacity for 6 AWG Aluminum XLP USE-2 RHH\/RHW-2 Direct Burial Building Wire: 45 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 data-start=\"293\" data-end=\"315\"\u003e\u003cstrong data-start=\"298\" data-end=\"313\"\u003eDescription\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"316\" data-end=\"890\"\u003eThis cable is a versatile power distribution cable with multiple ratings—RHH, RHW-2, XLP, and USE-2—designed for underground and raceway installations. The RHH rating indicates heat resistance for dry locations, while RHW-2 ensures water resistance and a 90°C maximum operating temperature in both wet and dry conditions. The XLP (cross-linked polyethylene) insulation enhances durability, abrasion resistance, and electrical performance. The USE-2 rating makes it suitable for service entrance installations below ground and direct burial.\u003c\/p\u003e\n\u003cp data-start=\"892\" data-end=\"1261\"\u003eUSE-2 cables are commonly used for power distribution, service entrance below ground, and direct burial, as well as in raceways. This electrical cable is approved under the National Electrical Code (NEC), except for use in cable trays. It supports a voltage rating of 600V and operates at a maximum temperature of 90°C in wet and dry environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-start=\"1267\" data-end=\"1305\"\u003eAmpacity Ratings (Per NEC 310.16):\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1308\" data-end=\"1405\"\u003e\n\u003cli data-start=\"1308\" data-end=\"1348\"\u003e\n\u003cstrong data-start=\"1310\" data-end=\"1332\"\u003eIn Free Air (90°C)\u003c\/strong\u003e → \u003cstrong data-start=\"1335\" data-end=\"1346\"\u003e55 Amps\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1349\" data-end=\"1405\"\u003e\n\u003cstrong data-start=\"1351\" data-end=\"1389\"\u003eIn Direct Burial or Raceway (90°C)\u003c\/strong\u003e → \u003cstrong data-start=\"1392\" data-end=\"1403\"\u003e45 Amps\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1407\" data-end=\"1453\"\u003e\u003cstrong data-start=\"1411\" data-end=\"1451\"\u003eCommon Applications for 6 AWG Cable:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1454\" data-end=\"1894\"\u003e\n\u003cli data-start=\"1454\" data-end=\"1544\"\u003e\n\u003cstrong data-start=\"1456\" data-end=\"1500\"\u003eSecondary underground power distribution\u003c\/strong\u003e for residential and commercial buildings.\u003c\/li\u003e\n\u003cli data-start=\"1545\" data-end=\"1631\"\u003e\n\u003cstrong data-start=\"1547\" data-end=\"1574\"\u003eService entrance wiring\u003c\/strong\u003e from utility transformers to meters or breaker panels.\u003c\/li\u003e\n\u003cli data-start=\"1632\" data-end=\"1715\"\u003e\n\u003cstrong data-start=\"1634\" data-end=\"1659\"\u003eRaceway installations\u003c\/strong\u003e where protection against abrasion and heat is needed.\u003c\/li\u003e\n\u003cli data-start=\"1716\" data-end=\"1800\"\u003e\n\u003cstrong data-start=\"1718\" data-end=\"1748\"\u003eDirect burial applications\u003c\/strong\u003e for power distribution without requiring conduit.\u003c\/li\u003e\n\u003cli data-start=\"1801\" data-end=\"1894\"\u003e\n\u003cstrong data-start=\"1803\" data-end=\"1834\"\u003eMoisture-prone environments\u003c\/strong\u003e, such as underground or outdoor electrical installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e6 aluminum rhh wire, 6 aluminum rhw cable, 6 aluminum bury cable, direct burial electrical cable, direct burial power cable, direct burial service entrance cable, direct burial wire, underground electrical wire, direct burial cable,\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eUL 44\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eUL 854\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eNEMA WC 70\/ICEA S-95-658\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eRequirements of the National Electrical Code\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eASTM B800, B801, B836\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eSunlight resistant\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eOil Resistant PRI\/PRII\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eGas and Oil Res GRI\/GRII\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eRUS ACCEPTED\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConstruction\u003c\/h3\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eConductors:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eCompact bare 8000 series aluminum, with Class B stranding per ASTM. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eInsulation:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003eAbrasion, heat and moisture resistant cross-linked polyethylene insulation (XLP)\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eGauge\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e6\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eStranding\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 7\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eConductor Diameter Inches\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 0.169\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eInsulation Thickness Inches\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 0.080\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eO.D. Inches\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 0.330\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eNew Weight lb\/1000FT\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 171 lbs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eAmpacity \u003c\/b\u003e\u003cb\u003eat 30°C\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 55 Amps\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable style=\"width: 382px; height: 151px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"width: 372px; height: 21px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 122px;\"\u003e\n\u003ctd style=\"width: 201.438px; height: 122px;\"\u003e\u003cstrong\u003eHouston item :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 247.562px; height: 122px;\"\u003e\n\u003cspan\u003e\u003cstrong\u003eBlack : \u003c\/strong\u003eHW003A00601\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eBlack : \u003c\/strong\u003e6-01XLPUSEBLACKAL\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"width: 184.188px; height: 35px;\"\u003e\u003cstrong\u003ePriority Wire \u0026amp; Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 181.812px; height: 35px;\"\u003e\n\u003cstrong\u003eBlack :\u003c\/strong\u003e 6-01XL-USE-2-ALUM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 65px;\"\u003e\n\u003ctd style=\"width: 201.438px; height: 65px;\"\u003e\u003cstrong\u003eSouthwire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 247.562px; height: 65px;\"\u003e\n\u003cstrong\u003eBlack :\u003c\/strong\u003e 27279901\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eApplication\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cp\u003eUSE-2 cables are primarily used for power distribution, in raceways in accordance with National Electrical Code, except that the cable is not rated for use in cable tray. USE-2 is approved for direct burial and for service entrance below ground. USE-2 cables may be used in wet or dry locations, with ambient temperatures not exceeding 90°C. Voltage rating for USE-2 cable is 600V. \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cp\u003eUSE-2 conductor is a soft drawn bare 8000 series aluminum, with Class B stranding per ASTM \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cp\u003eUSE-2 has abrasion, heat and moisture resistant cross-linked polyethylene insulation XLPE \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUSE-2 meets or exceeds the following standards \u003c\/li\u003e\n\u003cli\u003eUL 44 \u003c\/li\u003e\n\u003cli\u003eRequirements of the National Electrical Code \u003c\/li\u003e\n\u003cli\u003eASTM standards B 800, B 801 \u003c\/li\u003e\n\u003cli\u003eSunlight resistant \u003c\/li\u003e\n\u003cli\u003eRUS ACCEPTED\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Black","offer_id":42418579701914,"sku":"NNC1272X","price":0.59,"currency_code":"USD","in_stock":true},{"title":"Green","offer_id":42418579734682,"sku":"NNC1272X-2","price":0.59,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/Product2_69c5e302-aaa3-4f34-a88a-6035f0c4936c.png?v=1775571733"},{"product_id":"4-awg-aluminum-xlp-use-2-rhh-rhw-2-direct-burial-building-wire","title":"4 AWG Aluminum XLP USE-2 RHH\/RHW-2 Direct Burial Building Wire","description":"\u003cp\u003e[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/AL_XLP.pdf?v=1724417087\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e4 AWG Aluminum XLP USE-2 RHH\/RHW-2 Direct Burial Building Wire\u003c\/h2\u003e\n\u003cp data-end=\"368\" data-start=\"282\"\u003e\u003cstrong data-end=\"366\" data-start=\"282\"\u003eAllowable Ampacity for 4 AWG Aluminum XLP USE-2 RHH\/RHW-2 Direct Burial Building Wire: 65 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 data-end=\"392\" data-start=\"370\"\u003e\u003cstrong data-end=\"390\" data-start=\"375\"\u003eDescription\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-end=\"967\" data-start=\"393\"\u003eThis cable is a versatile power distribution cable with multiple ratings—RHH, RHW-2, XLP, and USE-2—designed for underground and raceway installations. The RHH rating indicates heat resistance for dry locations, while RHW-2 ensures water resistance and a 90°C maximum operating temperature in both wet and dry conditions. The XLP (cross-linked polyethylene) insulation enhances durability, abrasion resistance, and electrical performance. The USE-2 rating makes it suitable for service entrance installations below ground and direct burial.\u003c\/p\u003e\n\u003cp data-end=\"1338\" data-start=\"969\"\u003eUSE-2 cables are commonly used for power distribution, service entrance below ground, and direct burial, as well as in raceways. This electrical cable is approved under the National Electrical Code (NEC), except for use in cable trays. It supports a voltage rating of 600V and operates at a maximum temperature of 90°C in wet and dry environments.\u003c\/p\u003e\n\u003ch3 data-end=\"1384\" data-start=\"1340\"\u003e\u003cstrong data-end=\"1382\" data-start=\"1344\"\u003eAmpacity Ratings (Per NEC 310.16):\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-end=\"1482\" data-start=\"1385\"\u003e\n\u003cli data-end=\"1425\" data-start=\"1385\"\u003e\n\u003cstrong data-end=\"1409\" data-start=\"1387\"\u003eIn Free Air (90°C)\u003c\/strong\u003e → \u003cstrong data-end=\"1423\" data-start=\"1412\"\u003e85 Amps\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1482\" data-start=\"1426\"\u003e\n\u003cstrong data-end=\"1466\" data-start=\"1428\"\u003eIn Direct Burial or Raceway (90°C)\u003c\/strong\u003e → \u003cstrong data-end=\"1480\" data-start=\"1469\"\u003e65 Amps\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"1530\" data-start=\"1484\"\u003e\u003cstrong data-end=\"1528\" data-start=\"1488\"\u003eCommon Applications for 4 AWG Cable:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-end=\"1959\" data-start=\"1531\"\u003e\n\u003cli data-end=\"1646\" data-start=\"1531\"\u003e\n\u003cstrong data-end=\"1589\" data-start=\"1533\"\u003ePrimary and secondary underground power distribution\u003c\/strong\u003e for larger residential and light commercial buildings.\u003c\/li\u003e\n\u003cli data-end=\"1726\" data-start=\"1647\"\u003e\n\u003cstrong data-end=\"1676\" data-start=\"1649\"\u003eService entrance wiring\u003c\/strong\u003e for single-phase and three-phase power systems.\u003c\/li\u003e\n\u003cli data-end=\"1794\" data-start=\"1727\"\u003e\n\u003cstrong data-end=\"1748\" data-start=\"1729\"\u003eFeeder circuits\u003c\/strong\u003e for panelboards and distribution equipment.\u003c\/li\u003e\n\u003cli data-end=\"1864\" data-start=\"1795\"\u003e\n\u003cstrong data-end=\"1828\" data-start=\"1797\"\u003eDirect burial installations\u003c\/strong\u003e for medium-duty electrical loads.\u003c\/li\u003e\n\u003cli data-end=\"1959\" data-start=\"1865\"\u003e\n\u003cstrong data-end=\"1912\" data-start=\"1867\"\u003eIndustrial and agricultural installations\u003c\/strong\u003e requiring cost-effective underground wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e4 aluminum rhh wire, 4 aluminum rhw cable, 4 aluminum bury cable, direct burial electrical cable, direct burial power cable, direct burial service entrance cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eUL 44\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eUL 854\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eNEMA WC 70\/ICEA S-95-658\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eRequirements of the National Electrical Code\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eASTM B800, B801, B836\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eSunlight resistant\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eOil Resistant PRI\/PRII\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eGas and Oil Res GRI\/GRII\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eRUS ACCEPTED\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConstruction\u003c\/h3\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eConductors:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eCompact bare 8000 series aluminum, with Class B stranding per ASTM. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eInsulation:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003eAbrasion, heat and moisture resistant cross-linked polyethylene insulation (XLP)\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eGauge\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e4\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eStranding\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 7\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eConductor Diameter Inches\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 0.213\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eInsulation Thickness Inches\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 0.080\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eO.D. Inches\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 0.370\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eNew Weight lb\/1000FT\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 236 lbs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eAmpacity \u003c\/b\u003e\u003cb\u003eat 30°C\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 65 Amps\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable style=\"width: 382px; height: 151px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 372px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 119px;\"\u003e\n\u003ctd style=\"width: 216.469px; height: 119px;\"\u003e\u003cstrong\u003eHouston item :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 244.531px; height: 119px;\"\u003e\n\u003cspan\u003e\u003cstrong\u003eBlack : \u003c\/strong\u003eHW003A00401\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eBlack : \u003c\/strong\u003e4-01XLPUSEBLACKAL\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"width: 184.188px; height: 35px;\"\u003e\u003cstrong\u003ePriority Wire \u0026amp; Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 181.812px; height: 35px;\"\u003e\n\u003cstrong\u003eBlack :\u003c\/strong\u003e 4-01XL-USE-2-ALUM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 63px;\"\u003e\n\u003ctd style=\"width: 216.469px; height: 63px;\"\u003e\u003cstrong\u003eSouthwire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 244.531px; height: 63px;\"\u003e\n\u003cstrong\u003eBlack :\u003c\/strong\u003e 27280701\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cp\u003eUSE-2 cables are primarily used for power distribution, in raceways in accordance with National Electrical Code, except that the cable is not rated for use in cable tray. USE-2 is approved for direct burial and for service entrance below ground. USE-2 cables may be used in wet or dry locations, with ambient temperatures not exceeding 90°C. Voltage rating for USE-2 cable is 600V. \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cp\u003eUSE-2 conductor is a soft drawn bare 8000 series aluminum, with Class B stranding per ASTM \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cp\u003eUSE-2 has abrasion, heat and moisture resistant cross-linked polyethylene insulation XLPE \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUSE-2 meets or exceeds the following standards \u003c\/li\u003e\n\u003cli\u003eUL 44 \u003c\/li\u003e\n\u003cli\u003eRequirements of the National Electrical Code \u003c\/li\u003e\n\u003cli\u003eASTM standards B 800, B 801 \u003c\/li\u003e\n\u003cli\u003eSunlight resistant \u003c\/li\u003e\n\u003cli\u003eRUS ACCEPTED\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Black","offer_id":42418608898202,"sku":"NNC1273X","price":0.71,"currency_code":"USD","in_stock":true},{"title":"Green","offer_id":42418608930970,"sku":"NNC1273X-2","price":0.71,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/IMA_XLP_BLK_d2dfaa04-2c10-4fed-a5d8-790d136d6d93.png?v=1780986161"},{"product_id":"3-awg-aluminum-xlp-use-2-rhh-rhw-2-direct-burial-building-wire","title":"3 AWG Aluminum XLP USE-2 RHH\/RHW-2 Direct Burial Building Wire","description":"\u003cp\u003e[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/AL_XLP.pdf?v=1724417087\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e3 AWG Aluminum XLP USE-2 RHH\/RHW-2 Direct Burial Building Wire\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e for 3 AWG Aluminum XLP USE-2 RHH\/RHW-2 Direct Burial Building Wire: 75 Amps\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eApplications\u003cspan style=\"font-weight: 400;\"\u003e:\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003cspan\u003eUSE-2 cables are power distribution cables for service entrance below ground and direct burial, as well as raceways. The electrical cable is approved according to the National Electric Code, except for the use in cable trays. The maximum operating temperature for this electrical cable is 90°C in wet and dry locations. The voltage rating is 600 volts.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e3 AWG aluminum rhh wire, 3 aluminum rhw cable, 3 aluminum bury cable, direct burial electrical cable, direct burial power cable, direct burial service entrance cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eUL 44\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eUL 854\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eNEMA WC 70\/ICEA S-95-658\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eRequirements of the National Electrical Code\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eASTM B800, B801, B836\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eSunlight resistant\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eOil Resistant PRI\/PRII\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eGas and Oil Res GRI\/GRII\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eRUS ACCEPTED\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConstruction\u003c\/h3\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eConductors:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eCompact bare 8000 series aluminum, with Class B stranding per ASTM. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eInsulation:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003eAbrasion, heat and moisture resistant cross-linked polyethylene insulation (XLP)\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eGauge\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 3\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eStranding\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 7\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eConductor Diameter Inches\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 0.240\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eInsulation Thickness Inches\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 0.080\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eO.D. Inches\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 0.400\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eNew Weight lb\/1000FT\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 285 lbs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eAmpacity at 30°C\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 75 Amps\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable style=\"width: 398px; height: 106px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"width: 388px; height: 21px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18px;\"\u003e\n\u003ctd style=\"width: 164.047px; height: 18px;\"\u003e\u003cstrong\u003ePriority Wire \u0026amp; Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 217.953px; height: 18px;\"\u003e\n\u003cstrong\u003eBlack :\u003c\/strong\u003e 3-01XL-USE-2-ALUM\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Black","offer_id":42418629640346,"sku":"NNC1274X","price":0.0,"currency_code":"USD","in_stock":true},{"title":"Green","offer_id":42418629673114,"sku":"NNC1274X-2","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/IMA_XLP_BLK_d2dfaa04-2c10-4fed-a5d8-790d136d6d93.png?v=1780986161"},{"product_id":"2-awg-aluminum-xlp-use-2-rhh-rhw-2-direct-burial-building-wire","title":"2 AWG Aluminum XLP USE-2 RHH\/RHW-2 Direct Burial Building Wire","description":"\u003cp\u003e[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/AL_XLP.pdf?v=1724417087\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e2 AWG Aluminum XLP USE-2 RHH\/RHW-2 Direct Burial Building Wire\u003c\/h2\u003e\n\u003cp data-start=\"59\" data-end=\"145\"\u003e\u003cstrong data-start=\"59\" data-end=\"143\"\u003eAllowable Ampacity for 2 AWG Aluminum XLP USE-2 RHH\/RHW-2 Direct Burial Building Wire: 95 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 data-start=\"147\" data-end=\"169\"\u003e\u003cstrong data-start=\"152\" data-end=\"167\"\u003eDescription\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"170\" data-end=\"748\"\u003eThis cable is a high-capacity power distribution cable with multiple ratings—RHH, RHW-2, XLP, and USE-2—designed for underground and raceway installations. The RHH rating indicates heat resistance for dry locations, while RHW-2 ensures water resistance and a 90°C maximum operating temperature in both wet and dry conditions. The XLP (cross-linked polyethylene) insulation enhances durability, abrasion resistance, and electrical performance. The USE-2 rating makes it suitable for service entrance installations below ground and direct burial.\u003c\/p\u003e\n\u003cp data-start=\"750\" data-end=\"1119\"\u003eUSE-2 cables are commonly used for power distribution, service entrance below ground, and direct burial, as well as in raceways. This electrical cable is approved under the National Electrical Code (NEC), except for use in cable trays. It supports a voltage rating of 600V and operates at a maximum temperature of 90°C in wet and dry environments.\u003c\/p\u003e\n\u003ch3 data-start=\"1121\" data-end=\"1165\"\u003e\u003cstrong data-start=\"1125\" data-end=\"1163\"\u003eAmpacity Ratings (Per NEC 310.16):\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1166\" data-end=\"1264\"\u003e\n\u003cli data-start=\"1166\" data-end=\"1207\"\u003e\n\u003cstrong data-start=\"1168\" data-end=\"1190\"\u003eIn Free Air (90°C)\u003c\/strong\u003e → \u003cstrong data-start=\"1193\" data-end=\"1205\"\u003e115 Amps\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1208\" data-end=\"1264\"\u003e\n\u003cstrong data-start=\"1210\" data-end=\"1248\"\u003eIn Direct Burial or Raceway (90°C)\u003c\/strong\u003e → \u003cstrong data-start=\"1251\" data-end=\"1262\"\u003e95 Amps\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1266\" data-end=\"1312\"\u003e\u003cstrong data-start=\"1270\" data-end=\"1310\"\u003eCommon Applications for 2 AWG Cable:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1313\" data-end=\"1836\"\u003e\n\u003cli data-start=\"1313\" data-end=\"1421\"\u003e\n\u003cstrong data-start=\"1315\" data-end=\"1371\"\u003ePrimary and secondary underground power distribution\u003c\/strong\u003e for large residential and commercial buildings.\u003c\/li\u003e\n\u003cli data-start=\"1422\" data-end=\"1511\"\u003e\n\u003cstrong data-start=\"1424\" data-end=\"1451\"\u003eService entrance wiring\u003c\/strong\u003e for higher-capacity single-phase and three-phase systems.\u003c\/li\u003e\n\u003cli data-start=\"1512\" data-end=\"1612\"\u003e\n\u003cstrong data-start=\"1514\" data-end=\"1533\"\u003eFeeder circuits\u003c\/strong\u003e supplying power to large electrical panels, subpanels, and industrial loads.\u003c\/li\u003e\n\u003cli data-start=\"1613\" data-end=\"1721\"\u003e\n\u003cstrong data-start=\"1615\" data-end=\"1646\"\u003eDirect burial installations\u003c\/strong\u003e where higher ampacity and long-distance power transmission are required.\u003c\/li\u003e\n\u003cli data-start=\"1722\" data-end=\"1836\"\u003e\n\u003cstrong data-start=\"1724\" data-end=\"1778\"\u003eUtility, industrial, and agricultural applications\u003c\/strong\u003e needing durable, moisture-resistant underground wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1838\" data-end=\"2011\"\u003eThis \u003cstrong data-start=\"1843\" data-end=\"1867\"\u003e2 AWG aluminum cable\u003c\/strong\u003e is commonly selected for \u003cstrong data-start=\"1893\" data-end=\"2008\"\u003ehigh-power service entrances, long-run feeder circuits, and direct burial installations requiring up to 95 amps\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e2 aluminum rhh wire, 2 aluminum rhw cable, 2 aluminum bury cable, 2 direct burial electrical cable, 2 direct burial power cable, 2 95 amp direct burial cable, direct burial service entrance cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eUL 44\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eUL 854\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eNEMA WC 70\/ICEA S-95-658\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eRequirements of the National Electrical Code\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eASTM B800, B801, B836\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eSunlight resistant\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eOil Resistant PRI\/PRII\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eGas and Oil Res GRI\/GRII\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eRUS ACCEPTED\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConstruction\u003c\/h3\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eConductors:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eCompact bare 8000 series aluminum, with Class B stranding per ASTM. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eInsulation:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003eAbrasion, heat and moisture resistant cross-linked polyethylene insulation (XLP)\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eGauge\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e2\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eStranding\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 7\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eConductor Diameter Inches\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 0.268\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eInsulation Thickness Inches\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 0.080\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eO.D. Inches\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 0.430\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eNew Weight lb\/1000FT\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 337 lbs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eAmpacity \u003c\/b\u003e\u003cb\u003eat 30°C\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 95 Amps\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ctable style=\"width: 382px; height: 151px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"width: 394px; height: 21px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 54px;\"\u003e\n\u003ctd style=\"width: 195.25px; height: 54px;\"\u003e\u003cstrong\u003eHouston item :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 192.75px; height: 54px;\"\u003e\n\u003cspan\u003e\u003cstrong\u003eBlack : \u003c\/strong\u003eHW003A00201\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eBlack : \u003c\/strong\u003e2-01XLPUSEBLACKAL\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"width: 195.25px; height: 35px;\"\u003e\u003cstrong\u003ePriority Wire \u0026amp; Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 192.75px; height: 35px;\"\u003e\n\u003cstrong\u003eBlack :\u003c\/strong\u003e 2-01XL-USE-2-ALUM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 28px;\"\u003e\n\u003ctd style=\"width: 195.25px; height: 28px;\"\u003e\u003cstrong\u003eSouthwire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 192.75px; height: 28px;\"\u003e\n\u003cstrong\u003eBlack :\u003c\/strong\u003e 27282301\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Black","offer_id":42418644779162,"sku":"NNC1275X","price":0.84,"currency_code":"USD","in_stock":true},{"title":"Green","offer_id":42418644811930,"sku":"NNC1275X-2","price":0.84,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/IMA_XLP_BLK_d2dfaa04-2c10-4fed-a5d8-790d136d6d93.png?v=1780986161"},{"product_id":"1-awg-aluminum-xlp-use-2-rhh-rhw-2-direct-burial-building-wire","title":"1 AWG Aluminum XLP USE-2 RHH\/RHW-2 Direct Burial Building Wire","description":"\u003cp\u003e[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/AL_XLP.pdf?v=1724417087\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e1 AWG Aluminum XLP USE-2 RHH\/RHW-2 Direct Burial Building Wire\u003c\/h2\u003e\n\u003cp data-start=\"59\" data-end=\"146\"\u003e\u003cstrong data-start=\"59\" data-end=\"144\"\u003eAllowable Ampacity for 1 AWG Aluminum XLP USE-2 RHH\/RHW-2 Direct Burial Building Wire: 105 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 data-start=\"148\" data-end=\"170\"\u003e\u003cstrong data-start=\"153\" data-end=\"168\"\u003eDescription\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThis cable is a high-capacity power distribution cable with multiple ratings—RHH, RHW-2, XLP, and USE-2—designed for underground and raceway installations. The RHH rating ensures heat resistance in dry locations, while RHW-2 makes it water-resistant and suitable for 90°C operation in both wet and dry conditions. The XLP (cross-linked polyethylene) insulation enhances durability, abrasion resistance, and electrical performance. The USE-2 rating allows for direct burial and underground service entrance installations.\u003c\/p\u003e\n\u003cp\u003eUSE-2 cables are commonly used for power distribution, service entrance below ground, and direct burial, as well as in raceways. This electrical cable is approved under the National Electrical Code (NEC), except for use in cable trays. It supports a voltage rating of 600V and operates at a maximum temperature of 90°C in wet and dry environments.\u003c\/p\u003e\n\u003ch3 data-start=\"1098\" data-end=\"1142\"\u003e\u003cstrong data-start=\"1102\" data-end=\"1140\"\u003eAmpacity Ratings (Per NEC 310.16):\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1143\" data-end=\"1242\"\u003e\n\u003cli data-start=\"1143\" data-end=\"1184\"\u003e\n\u003cstrong data-start=\"1145\" data-end=\"1167\"\u003eIn Free Air (90°C)\u003c\/strong\u003e → \u003cstrong data-start=\"1170\" data-end=\"1182\"\u003e130 Amps\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1185\" data-end=\"1242\"\u003e\n\u003cstrong data-start=\"1187\" data-end=\"1225\"\u003eIn Direct Burial or Raceway (90°C)\u003c\/strong\u003e → \u003cstrong data-start=\"1228\" data-end=\"1240\"\u003e105 Amps\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1244\" data-end=\"1290\"\u003e\u003cstrong data-start=\"1248\" data-end=\"1288\"\u003eCommon Applications for 1 AWG Cable:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1291\" data-end=\"1795\"\u003e\n\u003cli data-start=\"1291\" data-end=\"1392\"\u003e\n\u003cstrong data-start=\"1293\" data-end=\"1349\"\u003ePrimary and secondary underground power distribution\u003c\/strong\u003e for commercial and industrial buildings.\u003c\/li\u003e\n\u003cli data-start=\"1393\" data-end=\"1480\"\u003e\n\u003cstrong data-start=\"1395\" data-end=\"1422\"\u003eService entrance wiring\u003c\/strong\u003e for high-capacity single-phase and three-phase systems.\u003c\/li\u003e\n\u003cli data-start=\"1481\" data-end=\"1576\"\u003e\n\u003cstrong data-start=\"1483\" data-end=\"1502\"\u003eFeeder circuits\u003c\/strong\u003e supplying large electrical panels, subpanels, and industrial equipment.\u003c\/li\u003e\n\u003cli data-start=\"1577\" data-end=\"1676\"\u003e\n\u003cstrong data-start=\"1579\" data-end=\"1610\"\u003eDirect burial installations\u003c\/strong\u003e for long-distance power transmission with minimal voltage drop.\u003c\/li\u003e\n\u003cli data-start=\"1677\" data-end=\"1795\"\u003e\n\u003cstrong data-start=\"1679\" data-end=\"1737\"\u003eUtility, agricultural, and infrastructure applications\u003c\/strong\u003e where durability and moisture resistance are essential.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1797\" data-end=\"1962\"\u003eThis \u003cstrong data-start=\"1802\" data-end=\"1826\"\u003e1 AWG aluminum cable\u003c\/strong\u003e is commonly used in \u003cstrong data-start=\"1847\" data-end=\"1959\"\u003elarge service entrances, high-power feeder circuits, and direct burial applications requiring up to 105 amps\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e1 aluminum rhh wire, 1 aluminum rhw cable, 1 aluminum bury cable, direct burial electrical cable, direct burial power cable, direct burial service entrance cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"font-weight: 400;\"\u003eUL 44\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eUL 854\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eNEMA WC 70\/ICEA S-95-658\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eRequirements of the National Electrical Code\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eASTM B800, B801, B836\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eSunlight resistant\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eOil Resistant PRI\/PRII\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eGas and Oil Res GRI\/GRII\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eRUS ACCEPTED\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConstruction\u003c\/h3\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eConductors:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eCompact bare 8000 series aluminum, with Class B stranding per ASTM. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eInsulation:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003eAbrasion, heat and moisture resistant cross-linked polyethylene insulation (XLP)\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eGauge\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eStranding\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 18\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eConductor Diameter Inches\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 0.299\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eInsulation Thickness Inches\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 0.095\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eO.D. Inches\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 0.490\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eNew Weight lb\/1000FT\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 429 lbs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eAmpacity \u003c\/b\u003e\u003cb\u003eat 30°C\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 105 Amps\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 423px; height: 200px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"width: 413px; height: 21px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 217.781px; height: 19px;\"\u003e\u003cstrong\u003eHouston Wire : \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.219px; height: 19px;\"\u003e\n\u003cstrong\u003eBlack :\u003c\/strong\u003e HW003A00101\u003cbr\u003e\u003cstrong\u003eBlack : \u003c\/strong\u003e1-01XLPUSEBLACKAL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 217.781px; height: 19px;\"\u003e\u003cstrong\u003eSouthwire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.219px; height: 19px;\"\u003e\n\u003cstrong\u003eBlack :\u003c\/strong\u003e 27283101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 32px;\"\u003e\n\u003ctd style=\"width: 217.781px;\"\u003e\u003cstrong\u003ePriority Wire \u0026amp; Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.219px;\"\u003e\n\u003cstrong\u003eBlack : \u003c\/strong\u003e1-01XL-USE-2-ALUM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Black","offer_id":42418675220634,"sku":"NNC1276X","price":0.92,"currency_code":"USD","in_stock":true},{"title":"Green","offer_id":42418675253402,"sku":"NNC1276X-2","price":0.92,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/IMA_XLP_BLK_d2dfaa04-2c10-4fed-a5d8-790d136d6d93.png?v=1780986161"},{"product_id":"1-0-awg-aluminum-xlp-use-2-rhh-rhw-2-direct-burial-building-wire","title":"1\/0 AWG Aluminum XLP USE-2 RHH\/RHW-2 Direct Burial Building Wire","description":"\u003cp\u003e[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/AL_XLP.pdf?v=1724417087\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e1\/0 AWG Aluminum XLP USE-2 RHH\/RHW-2 Direct Burial Building Wire\u003c\/h2\u003e\n\u003cp data-end=\"150\" data-start=\"61\"\u003e\u003cstrong data-end=\"148\" data-start=\"61\"\u003eAllowable Ampacity for 1\/0 AWG Aluminum XLP USE-2 RHH\/RHW-2 Direct Burial Building Wire: 120 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 data-end=\"174\" data-start=\"152\"\u003e\u003cstrong data-end=\"172\" data-start=\"157\"\u003eDescription\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-end=\"726\" data-start=\"175\"\u003eThis cable is a heavy-duty power distribution cable with multiple ratings—RHH, RHW-2, XLP, and USE-2—designed for underground and raceway installations. The RHH rating ensures heat resistance in dry locations, while RHW-2 makes it water-resistant and suitable for 90°C operation in both wet and dry conditions. The XLP (cross-linked polyethylene) insulation enhances durability, abrasion resistance, and electrical performance. The USE-2 rating allows for direct burial and underground service entrance installations.\u003c\/p\u003e\n\u003cp data-end=\"1097\" data-start=\"728\"\u003eUSE-2 cables are commonly used for power distribution, service entrance below ground, and direct burial, as well as in raceways. This electrical cable is approved under the National Electrical Code (NEC), except for use in cable trays. It supports a voltage rating of 600V and operates at a maximum temperature of 90°C in wet and dry environments.\u003c\/p\u003e\n\u003ch3 data-end=\"1143\" data-start=\"1099\"\u003e\u003cstrong data-end=\"1141\" data-start=\"1103\"\u003eAmpacity Ratings (Per NEC 310.16):\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-end=\"1243\" data-start=\"1144\"\u003e\n\u003cli data-end=\"1185\" data-start=\"1144\"\u003e\n\u003cstrong data-end=\"1168\" data-start=\"1146\"\u003eIn Free Air (90°C)\u003c\/strong\u003e → \u003cstrong data-end=\"1183\" data-start=\"1171\"\u003e150 Amps\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1243\" data-start=\"1186\"\u003e\n\u003cstrong data-end=\"1226\" data-start=\"1188\"\u003eIn Direct Burial or Raceway (90°C)\u003c\/strong\u003e → \u003cstrong data-end=\"1241\" data-start=\"1229\"\u003e120 Amps\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"1293\" data-start=\"1245\"\u003e\u003cstrong data-end=\"1291\" data-start=\"1249\"\u003eCommon Applications for 1\/0 AWG Cable:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-end=\"1819\" data-start=\"1294\"\u003e\n\u003cli data-end=\"1420\" data-start=\"1294\"\u003e\n\u003cstrong data-end=\"1352\" data-start=\"1296\"\u003ePrimary and secondary underground power distribution\u003c\/strong\u003e for commercial, industrial, and multi-unit residential buildings.\u003c\/li\u003e\n\u003cli data-end=\"1511\" data-start=\"1421\"\u003e\n\u003cstrong data-end=\"1450\" data-start=\"1423\"\u003eService entrance wiring\u003c\/strong\u003e for large single-phase and three-phase electrical systems.\u003c\/li\u003e\n\u003cli data-end=\"1600\" data-start=\"1512\"\u003e\n\u003cstrong data-end=\"1533\" data-start=\"1514\"\u003eFeeder circuits\u003c\/strong\u003e for high-capacity panels, subpanels, and heavy electrical loads.\u003c\/li\u003e\n\u003cli data-end=\"1700\" data-start=\"1601\"\u003e\n\u003cstrong data-end=\"1634\" data-start=\"1603\"\u003eDirect burial installations\u003c\/strong\u003e for long-distance power transmission with minimal voltage drop.\u003c\/li\u003e\n\u003cli data-end=\"1819\" data-start=\"1701\"\u003e\n\u003cstrong data-end=\"1757\" data-start=\"1703\"\u003eUtility, industrial, and agricultural applications\u003c\/strong\u003e requiring a reliable, moisture-resistant underground cable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"1970\" data-start=\"1821\"\u003eThis \u003cstrong data-end=\"1852\" data-start=\"1826\"\u003e1\/0 AWG aluminum cable\u003c\/strong\u003e is ideal for \u003cstrong data-end=\"1967\" data-start=\"1866\"\u003elarge service entrances, feeder circuits, and direct burial applications requiring up to 120 amps\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e1\/0 aluminum rhh wire, \u003cspan\u003e1\/0 \u003c\/span\u003ealuminum rhw cable, \u003cspan\u003e1\/0 \u003c\/span\u003ealuminum bury cable, direct burial electrical cable, direct burial power cable, direct burial service entrance cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eUL 44\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eUL 854\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eNEMA WC 70\/ICEA S-95-658\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eRequirements of the National Electrical Code\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eASTM B800, B801, B836\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eSunlight resistant\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eOil Resistant PRI\/PRII\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eGas and Oil Res GRI\/GRII\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eRUS ACCEPTED\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConstruction\u003c\/h3\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eConductors:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eCompact bare 8000 series aluminum, with Class B stranding per ASTM. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eInsulation:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003eAbrasion, heat and moisture resistant cross-linked polyethylene insulation (XLP)\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eGauge\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e1\/0\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eStranding\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 18\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eConductor Diameter Inches\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 0.335\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eInsulation Thickness Inches\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 0.095\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eO.D. Inches\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 0.530\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eNew Weight lb\/1000FT\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 515 lbs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eAmpacity \u003c\/b\u003e\u003cb\u003eat 30°C\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 120 Amps\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ctable style=\"width: 382px; height: 151px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"width: 372px; height: 21px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 54px;\"\u003e\n\u003ctd style=\"width: 195.25px;\"\u003e\u003cstrong\u003eHouston item :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 192.75px;\"\u003e\n\u003cspan\u003e\u003cstrong\u003eBlack : \u003c\/strong\u003eHW003A10101\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eBlack : \u003c\/strong\u003e1\/0-01XLPUSEBLACKAL\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"width: 184.188px; height: 35px;\"\u003e\u003cstrong\u003ePriority Wire \u0026amp; Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 181.812px; height: 35px;\"\u003e\n\u003cstrong\u003eBlack :\u003c\/strong\u003e 1\/0-01XL-USE-2-ALUM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 28px;\"\u003e\n\u003ctd style=\"width: 195.25px;\"\u003e\u003cstrong\u003eSouthwire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 192.75px;\"\u003e\n\u003cstrong\u003eBlack :\u003c\/strong\u003e 27284901\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National cable","offers":[{"title":"Black","offer_id":42418701041818,"sku":"NNC1277X","price":1.09,"currency_code":"USD","in_stock":true},{"title":"Green","offer_id":42418701074586,"sku":"NNC1277X-2","price":1.09,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/IMA_XLP_BLK_26e26bbf-b672-401b-98ed-30a1346fc279.png?v=1780986145"},{"product_id":"2-0-awg-aluminum-xlp-use-2-rhh-rhw-2-direct-burial-building-wire","title":"2\/0 AWG Aluminum XLP USE-2 RHH\/RHW-2 Direct Burial Building Wire","description":"\u003cp\u003e[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/AL_XLP.pdf?v=1724417087\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e2\/0 AWG Aluminum XLP USE-2 RHH\/RHW-2 Direct Burial Building Wire\u003c\/h2\u003e\n\u003cp data-start=\"61\" data-end=\"150\"\u003e\u003cstrong data-start=\"61\" data-end=\"148\"\u003eAllowable Ampacity for 2\/0 AWG Aluminum XLP USE-2 RHH\/RHW-2 Direct Burial Building Wire: 145 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 data-start=\"152\" data-end=\"174\"\u003e\u003cstrong data-start=\"157\" data-end=\"172\"\u003eDescription\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"175\" data-end=\"729\"\u003eThis cable is a high-capacity power distribution cable with multiple ratings—RHH, RHW-2, XLP, and USE-2—designed for underground and raceway installations. The RHH rating ensures heat resistance in dry locations, while RHW-2 makes it water-resistant and suitable for 90°C operation in both wet and dry conditions. The XLP (cross-linked polyethylene) insulation enhances durability, abrasion resistance, and electrical performance. The USE-2 rating allows for direct burial and underground service entrance installations.\u003c\/p\u003e\n\u003cp data-start=\"731\" data-end=\"1100\"\u003eUSE-2 cables are commonly used for power distribution, service entrance below ground, and direct burial, as well as in raceways. This electrical cable is approved under the National Electrical Code (NEC), except for use in cable trays. It supports a voltage rating of 600V and operates at a maximum temperature of 90°C in wet and dry environments.\u003c\/p\u003e\n\u003ch3 data-start=\"1102\" data-end=\"1146\"\u003e\u003cstrong data-start=\"1106\" data-end=\"1144\"\u003eAmpacity Ratings (Per NEC 310.16):\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1147\" data-end=\"1246\"\u003e\n\u003cli data-start=\"1147\" data-end=\"1188\"\u003e\n\u003cstrong data-start=\"1149\" data-end=\"1171\"\u003eIn Free Air (90°C)\u003c\/strong\u003e → \u003cstrong data-start=\"1174\" data-end=\"1186\"\u003e175 Amps\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1189\" data-end=\"1246\"\u003e\n\u003cstrong data-start=\"1191\" data-end=\"1229\"\u003eIn Direct Burial or Raceway (90°C)\u003c\/strong\u003e → \u003cstrong data-start=\"1232\" data-end=\"1244\"\u003e145 Amps\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1248\" data-end=\"1296\"\u003e\u003cstrong data-start=\"1252\" data-end=\"1294\"\u003eCommon Applications for 2\/0 AWG Cable:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1297\" data-end=\"1825\"\u003e\n\u003cli data-start=\"1297\" data-end=\"1418\"\u003e\n\u003cstrong data-start=\"1299\" data-end=\"1355\"\u003ePrimary and secondary underground power distribution\u003c\/strong\u003e for commercial, industrial, and large residential buildings.\u003c\/li\u003e\n\u003cli data-start=\"1419\" data-end=\"1517\"\u003e\n\u003cstrong data-start=\"1421\" data-end=\"1448\"\u003eService entrance wiring\u003c\/strong\u003e for high-capacity single-phase and three-phase electrical systems.\u003c\/li\u003e\n\u003cli data-start=\"1518\" data-end=\"1603\"\u003e\n\u003cstrong data-start=\"1520\" data-end=\"1539\"\u003eFeeder circuits\u003c\/strong\u003e for high-power panels, subpanels, and heavy industrial loads.\u003c\/li\u003e\n\u003cli data-start=\"1604\" data-end=\"1703\"\u003e\n\u003cstrong data-start=\"1606\" data-end=\"1637\"\u003eDirect burial installations\u003c\/strong\u003e for long-distance power transmission with minimal voltage drop.\u003c\/li\u003e\n\u003cli data-start=\"1704\" data-end=\"1825\"\u003e\n\u003cstrong data-start=\"1706\" data-end=\"1764\"\u003eUtility, infrastructure, and agricultural applications\u003c\/strong\u003e where high ampacity and moisture resistance are essential.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1827\" data-end=\"1980\"\u003eThis \u003cstrong data-start=\"1832\" data-end=\"1858\"\u003e2\/0 AWG aluminum cable\u003c\/strong\u003e is ideal for \u003cstrong data-start=\"1872\" data-end=\"1977\"\u003elarge service entrances, feeder circuits, and underground power distribution requiring up to 145 amps\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eAluminum rhh wire, aluminum rhw cable, aluminum bury cable, direct burial electrical cable, direct buri\u003c\/span\u003eal power cable, direct burial service entrance cable, aluminum wire, \u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003euse-2 aluminum wire\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eUL 44\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eUL 854\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eNEMA WC 70\/ICEA S-95-658\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eRequirements of the National Electrical Code\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eASTM B800, B801, B836\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eSunlight resistant\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eOil Resistant PRI\/PRII\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eGas and Oil Res GRI\/GRII\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eRUS ACCEPTED\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConstruction\u003c\/h3\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eConductors:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eCompact bare 8000 series aluminum, with Class B stranding per ASTM. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eInsulation:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003eAbrasion, heat and moisture resistant cross-linked polyethylene insulation (XLP)\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eGauge\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e2\/0\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eStranding\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 18\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eConductor Diameter Inches\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 0.378\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eInsulation Thickness Inches\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 0.095\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eO.D. Inches\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 0.570\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eNew Weight lb\/1000FT\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 623 lbs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eAmpacity \u003c\/b\u003e\u003cb\u003eat 30C\u003cmeta charset=\"utf-8\"\u003e°\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 145 Amps\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ctable style=\"width: 382px; height: 151px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"width: 372px; height: 21px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 54px;\"\u003e\n\u003ctd style=\"width: 118.188px; height: 54px;\"\u003e\u003cstrong\u003eHouston item :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 233.812px; height: 54px;\"\u003e\n\u003cspan\u003e\u003cstrong\u003eBlack : \u003c\/strong\u003eHW003A20101\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eBlack : \u003c\/strong\u003e2\/0-01XLPUSEBLACKAL\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"width: 184.188px; height: 35px;\"\u003e\u003cstrong\u003ePriority Wire \u0026amp; Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 181.812px; height: 35px;\"\u003e\n\u003cstrong\u003eBlack :\u003c\/strong\u003e 2\/0-01XL-USE-2-ALUM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 28px;\"\u003e\n\u003ctd style=\"width: 118.188px; height: 28px;\"\u003e\u003cstrong\u003eSouthwire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 233.812px; height: 28px;\"\u003e\n\u003cstrong\u003eBlack :\u003c\/strong\u003e 27285601\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Black","offer_id":42418723225754,"sku":"NNC1278X","price":1.39,"currency_code":"USD","in_stock":true},{"title":"Green","offer_id":42418723324058,"sku":"NNC1278X-2","price":1.39,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/IMA_XLP_BLK_f083f472-8242-4315-927e-2dcc2b7b6d8d.png?v=1780985984"},{"product_id":"3-0-awg-aluminum-xlp-use-2-rhh-rhw-2-direct-burial-building-wire","title":"3\/0 AWG Aluminum XLP USE-2 RHH\/RHW-2 Direct Burial Building Wire","description":"\u003cp\u003e[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/AL_XLP.pdf?v=1724417087\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e3\/0 AWG Aluminum XLP USE-2 RHH\/RHW-2 Direct Burial Building Wire\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cp data-end=\"150\" data-start=\"61\"\u003e\u003cstrong data-end=\"148\" data-start=\"61\"\u003eAllowable Ampacity for 3\/0 AWG Aluminum XLP USE-2 RHH\/RHW-2 Direct Burial Building Wire: 165 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 data-end=\"174\" data-start=\"152\"\u003e\u003cstrong data-end=\"172\" data-start=\"157\"\u003eDescription\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-end=\"726\" data-start=\"175\"\u003eThis cable is a heavy-duty power distribution cable with multiple ratings—RHH, RHW-2, XLP, and USE-2—designed for underground and raceway installations. The RHH rating ensures heat resistance in dry locations, while RHW-2 makes it water-resistant and suitable for 90°C operation in both wet and dry conditions. The XLP (cross-linked polyethylene) insulation enhances durability, abrasion resistance, and electrical performance. The USE-2 rating allows for direct burial and underground service entrance installations.\u003c\/p\u003e\n\u003cp data-end=\"1097\" data-start=\"728\"\u003eUSE-2 cables are commonly used for power distribution, service entrance below ground, and direct burial, as well as in raceways. This electrical cable is approved under the National Electrical Code (NEC), except for use in cable trays. It supports a voltage rating of 600V and operates at a maximum temperature of 90°C in wet and dry environments.\u003c\/p\u003e\n\u003ch3 data-end=\"1143\" data-start=\"1099\"\u003e\u003cstrong data-end=\"1141\" data-start=\"1103\"\u003eAmpacity Ratings (Per NEC 310.16):\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-end=\"1243\" data-start=\"1144\"\u003e\n\u003cli data-end=\"1185\" data-start=\"1144\"\u003e\n\u003cstrong data-end=\"1168\" data-start=\"1146\"\u003eIn Free Air (90°C)\u003c\/strong\u003e → \u003cstrong data-end=\"1183\" data-start=\"1171\"\u003e200 Amps\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1243\" data-start=\"1186\"\u003e\n\u003cstrong data-end=\"1226\" data-start=\"1188\"\u003eIn Direct Burial or Raceway (90°C)\u003c\/strong\u003e → \u003cstrong data-end=\"1241\" data-start=\"1229\"\u003e165 Amps\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"1293\" data-start=\"1245\"\u003e\u003cstrong data-end=\"1291\" data-start=\"1249\"\u003eCommon Applications for 3\/0 AWG Cable:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-end=\"1829\" data-start=\"1294\"\u003e\n\u003cli data-end=\"1426\" data-start=\"1294\"\u003e\n\u003cstrong data-end=\"1352\" data-start=\"1296\"\u003ePrimary and secondary underground power distribution\u003c\/strong\u003e for large commercial, industrial, and multi-unit residential buildings.\u003c\/li\u003e\n\u003cli data-end=\"1525\" data-start=\"1427\"\u003e\n\u003cstrong data-end=\"1456\" data-start=\"1429\"\u003eService entrance wiring\u003c\/strong\u003e for high-capacity single-phase and three-phase electrical systems.\u003c\/li\u003e\n\u003cli data-end=\"1617\" data-start=\"1526\"\u003e\n\u003cstrong data-end=\"1547\" data-start=\"1528\"\u003eFeeder circuits\u003c\/strong\u003e for large electrical panels, subpanels, and heavy industrial loads.\u003c\/li\u003e\n\u003cli data-end=\"1717\" data-start=\"1618\"\u003e\n\u003cstrong data-end=\"1651\" data-start=\"1620\"\u003eDirect burial installations\u003c\/strong\u003e for long-distance power transmission with minimal voltage drop.\u003c\/li\u003e\n\u003cli data-end=\"1829\" data-start=\"1718\"\u003e\n\u003cstrong data-end=\"1778\" data-start=\"1720\"\u003eUtility, infrastructure, and agricultural applications\u003c\/strong\u003e requiring high ampacity and moisture resistance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"1999\" data-start=\"1831\"\u003eThis \u003cstrong data-end=\"1862\" data-start=\"1836\"\u003e3\/0 AWG aluminum cable\u003c\/strong\u003e is commonly used for \u003cstrong data-end=\"1996\" data-start=\"1884\"\u003elarge service entrances, high-power feeder circuits, and direct burial applications requiring up to 165 amps\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e\u003cspan\u003e3\/0 a\u003c\/span\u003eluminum rhh wire, \u003cspan\u003e3\/0 \u003c\/span\u003ealuminum rhw cable, \u003cspan\u003e3\/0 \u003c\/span\u003ealuminum bury cable, direct burial electrical cable, direct burial power cable, direct burial service entrance cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eUL 44\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eUL 854\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eNEMA WC 70\/ICEA S-95-658\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eRequirements of the National Electrical Code\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eASTM B800, B801, B836\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eSunlight resistant\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eOil Resistant PRI\/PRII\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eGas and Oil Res GRI\/GRII\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eRUS ACCEPTED\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConstruction\u003c\/h3\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eConductors:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eCompact bare 8000 series aluminum, with Class B stranding per ASTM. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eInsulation:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003eAbrasion, heat and moisture resistant cross-linked polyethylene insulation (XLP)\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eGauge\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e3\/0\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eStranding\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 18\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eConductor Diameter Inches\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 0.423\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eInsulation Thickness Inches\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 0.080\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eO.D. Inches\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 0.586\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eNew Weight lb\/1000FT\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 221 lbs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eAmpacity \u003c\/b\u003e\u003cb\u003eat 30°C\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 165 Amps\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ctable style=\"width: 382px; height: 151px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 372px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 98px;\"\u003e\n\u003ctd style=\"width: 137.359px; height: 98px;\"\u003e\u003cstrong\u003eHouston item :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 245.641px; height: 98px;\"\u003e\n\u003cspan\u003e\u003cstrong\u003eBlack : \u003c\/strong\u003eHW003A30101\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eBlack : \u003c\/strong\u003e3\/0-01XLPUSEBLACKAL\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"width: 184.188px; height: 35px;\"\u003e\u003cstrong\u003ePriority Wire \u0026amp; Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 181.812px; height: 35px;\"\u003e\n\u003cstrong\u003eBlack :\u003c\/strong\u003e 3\/0-01XL-USE-2-ALUM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 51px;\"\u003e\n\u003ctd style=\"width: 137.359px; height: 51px;\"\u003e\u003cstrong\u003eSouthwire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 245.641px; height: 51px;\"\u003e\n\u003cstrong\u003eBlack :\u003c\/strong\u003e 27286401\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Black","offer_id":42418790727834,"sku":"NNC1279X","price":1.49,"currency_code":"USD","in_stock":true},{"title":"Green","offer_id":42418790760602,"sku":"NNC1279X-2","price":1.49,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/IMA_XLP_BLK_f083f472-8242-4315-927e-2dcc2b7b6d8d.png?v=1780985984"},{"product_id":"4-0-awg-aluminum-xlp-use-2-rhh-rhw-2-direct-burial-building-wire","title":"4\/0 AWG Aluminum XLP USE-2 RHH\/RHW-2 Direct Burial Building Wire","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/AL_XLP.pdf?v=1724417087\" width=\"\" height=\"\" type=\"application\/pdf\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e4\/0 AWG Aluminum XLP USE-2 RHH\/RHW-2 Direct Burial Building Wire\u003c\/h2\u003e\n\u003cp data-end=\"150\" data-start=\"61\"\u003e\u003cstrong data-end=\"148\" data-start=\"61\"\u003eAllowable Ampacity for 4\/0 AWG Aluminum XLP USE-2 RHH\/RHW-2 Direct Burial Building Wire: 185 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 data-end=\"174\" data-start=\"152\"\u003e\u003cstrong data-end=\"172\" data-start=\"157\"\u003eDescription\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-end=\"729\" data-start=\"175\"\u003eThis cable is a high-capacity power distribution cable with multiple ratings—RHH, RHW-2, XLP, and USE-2—designed for underground and raceway installations. The RHH rating ensures heat resistance in dry locations, while RHW-2 makes it water-resistant and suitable for 90°C operation in both wet and dry conditions. The XLP (cross-linked polyethylene) insulation enhances durability, abrasion resistance, and electrical performance. The USE-2 rating allows for direct burial and underground service entrance installations.\u003c\/p\u003e\n\u003cp data-end=\"1100\" data-start=\"731\"\u003eUSE-2 cables are commonly used for power distribution, service entrance below ground, and direct burial, as well as in raceways. This electrical cable is approved under the National Electrical Code (NEC), except for use in cable trays. It supports a voltage rating of 600V and operates at a maximum temperature of 90°C in wet and dry environments.\u003c\/p\u003e\n\u003ch3 data-end=\"1146\" data-start=\"1102\"\u003e\u003cstrong data-end=\"1144\" data-start=\"1106\"\u003eAmpacity Ratings (Per NEC 310.16):\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-end=\"1246\" data-start=\"1147\"\u003e\n\u003cli data-end=\"1188\" data-start=\"1147\"\u003e\n\u003cstrong data-end=\"1171\" data-start=\"1149\"\u003eIn Free Air (90°C)\u003c\/strong\u003e → \u003cstrong data-end=\"1186\" data-start=\"1174\"\u003e230 Amps\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1246\" data-start=\"1189\"\u003e\n\u003cstrong data-end=\"1229\" data-start=\"1191\"\u003eIn Direct Burial or Raceway (90°C)\u003c\/strong\u003e → \u003cstrong data-end=\"1244\" data-start=\"1232\"\u003e185 Amps\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"1296\" data-start=\"1248\"\u003e\u003cstrong data-end=\"1294\" data-start=\"1252\"\u003eCommon Applications for 4\/0 AWG Cable:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-end=\"1850\" data-start=\"1297\"\u003e\n\u003cli data-end=\"1429\" data-start=\"1297\"\u003e\n\u003cstrong data-end=\"1355\" data-start=\"1299\"\u003ePrimary and secondary underground power distribution\u003c\/strong\u003e for large commercial, industrial, and multi-unit residential buildings.\u003c\/li\u003e\n\u003cli data-end=\"1528\" data-start=\"1430\"\u003e\n\u003cstrong data-end=\"1459\" data-start=\"1432\"\u003eService entrance wiring\u003c\/strong\u003e for high-capacity single-phase and three-phase electrical systems.\u003c\/li\u003e\n\u003cli data-end=\"1638\" data-start=\"1529\"\u003e\n\u003cstrong data-end=\"1550\" data-start=\"1531\"\u003eFeeder circuits\u003c\/strong\u003e supplying power to large switchgear, distribution panels, and heavy electrical loads.\u003c\/li\u003e\n\u003cli data-end=\"1738\" data-start=\"1639\"\u003e\n\u003cstrong data-end=\"1672\" data-start=\"1641\"\u003eDirect burial installations\u003c\/strong\u003e for long-distance power transmission with minimal voltage drop.\u003c\/li\u003e\n\u003cli data-end=\"1850\" data-start=\"1739\"\u003e\n\u003cstrong data-end=\"1799\" data-start=\"1741\"\u003eUtility, infrastructure, and agricultural applications\u003c\/strong\u003e requiring high ampacity and moisture resistance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"2020\" data-start=\"1852\"\u003eThis \u003cstrong data-end=\"1883\" data-start=\"1857\"\u003e4\/0 AWG aluminum cable\u003c\/strong\u003e is commonly used for \u003cstrong data-end=\"2017\" data-start=\"1905\"\u003elarge service entrances, industrial feeder circuits, and direct burial applications requiring up to 185 amps\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e\u003cspan\u003e4\/0 AWG \u003c\/span\u003ealuminum rhh wire, \u003cspan\u003e4\/0 AWG \u003c\/span\u003ealuminum rhw cable, \u003cspan\u003e4\/0 \u003c\/span\u003ealuminum bury cable, direct burial electrical cable, direct burial power cable, direct burial service entrance cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eUL 44\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eUL 854\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eNEMA WC 70\/ICEA S-95-658\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eRequirements of the National Electrical Code\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eASTM B800, B801, B836\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eSunlight resistant\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eOil Resistant PRI\/PRII\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eGas and Oil Res GRI\/GRII\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eRUS ACCEPTED\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConstruction\u003c\/h3\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eConductors:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eCompact bare 8000 series aluminum, with Class B stranding per ASTM. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eInsulation:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003eAbrasion, heat and moisture resistant cross-linked polyethylene insulation (XLP)\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eGauge\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e4\/0\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eStranding\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 18\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eConductor Diameter Inches\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 0.476\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eInsulation Thickness Inches\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 0.095\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eO.D. Inches\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 0.670\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eNew Weight lb\/1000FT\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 902 lbs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eAmpacity \u003c\/b\u003e\u003cb\u003eat 30°C\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 185 Amps\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ctable style=\"width: 382px; height: 151px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 372px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 60px;\"\u003e\n\u003ctd style=\"width: 195.25px;\"\u003e\u003cstrong\u003eHouston item :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 192.75px;\"\u003e\n\u003cspan\u003e\u003cstrong\u003eBlack : \u003c\/strong\u003eHW003A40101\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eBlack : \u003c\/strong\u003e4\/0-01XLPUSEBLACKAL\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"width: 184.188px; height: 35px;\"\u003e\u003cstrong\u003ePriority Wire \u0026amp; Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 181.812px; height: 35px;\"\u003e\n\u003cstrong\u003eBlack :\u003c\/strong\u003e 4\/0-01XL-USE-2-ALUM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 31px;\"\u003e\n\u003ctd style=\"width: 195.25px;\"\u003e\u003cstrong\u003eSouthwire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 192.75px;\"\u003e\n\u003cstrong\u003eBlack :\u003c\/strong\u003e 27287201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Black","offer_id":63404115788145,"sku":"NNC1280X","price":1.59,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/IMA_XLP_BLK_22b8bcc1-e137-440d-879c-4be697329de6.png?v=1780986042"},{"product_id":"8-awg-aluminum-xlp-use-2-rhh-rhw-2-direct-burial-building-wire","title":"8 AWG Aluminum XLP USE-2 RHH\/RHW-2 Direct Burial Building Wire","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/AL_XLP.pdf?v=1724417087\" width=\"\" height=\"\" type=\"application\/pdf\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch2\u003e8 AWG Aluminum XLP USE-2 RHH\/RHW-2 Direct Burial Building Wire\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e for 8 AWG Aluminum XLP USE-2 RHH\/RHW-2 Direct Burial Building Wire: 30 Amps\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003cspan\u003eUSE-2 cables are power distribution cables for service entrance below ground and direct burial, as well as raceways. The electrical cable is approved according to the National Electric Code, except for the use in cable trays. The maximum operating temperature for this electrical cable is 90°C in wet and dry locations. The voltage rating is 600 volts.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e8 aluminum rhh wire, 8 aluminum rhw cable, 8 aluminum bury cable, direct burial electrical cable, direct burial power cable, direct burial service entrance cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eUL 44\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eUL 854\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eNEMA WC 70\/ICEA S-95-658\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eRequirements of the National Electrical Code\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eASTM B800, B801, B836\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eSunlight resistant\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eOil Resistant PRI\/PRII\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eGas and Oil Res GRI\/GRII\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eRUS ACCEPTED\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConstruction\u003c\/h3\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eConductors:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eCompact bare 8000 series aluminum, with Class B stranding per ASTM. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eInsulation:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003eAbrasion, heat and moisture resistant cross-linked polyethylene insulation (XLP)\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eGauge\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 8\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eStranding\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 7\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eConductor Diameter Inches\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 0.134\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eInsulation Thickness Inches\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 0.080\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eO.D. Inches\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 0.290\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eNew Weight lb\/1000FT\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 125 lbs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eAmpacity at 30°C\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 30 Amps\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable style=\"width: 382px; height: 151px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 372px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"width: 184.188px; height: 35px;\"\u003e\u003cstrong\u003ePriority Wire \u0026amp; Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 181.812px; height: 35px;\"\u003e\n\u003cstrong\u003eBlack :\u003c\/strong\u003e 8-01XL-USE-2-ALUM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cp\u003eUSE-2 cables are primarily used for power distribution, in raceways in accordance with National Electrical Code, except that the cable is not rated for use in cable tray. USE-2 is approved for direct burial and for service entrance below ground. USE-2 cables may be used in wet or dry locations, with ambient temperatures not exceeding 90°C. Voltage rating for USE-2 cable is 600V. \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cp\u003eUSE-2 conductor is a soft drawn bare 8000 series aluminum, with Class B stranding per ASTM \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cp\u003eUSE-2 has abrasion, heat and moisture resistant cross-linked polyethylene insulation XLPE \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUSE-2 meets or exceeds the following standards \u003c\/li\u003e\n\u003cli\u003eUL 44 \u003c\/li\u003e\n\u003cli\u003eRequirements of the National Electrical Code \u003c\/li\u003e\n\u003cli\u003eASTM standards B 800, B 801 \u003c\/li\u003e\n\u003cli\u003eSunlight resistant \u003c\/li\u003e\n\u003cli\u003eRUS ACCEPTED\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nassau National Cable","offers":[{"title":"Black","offer_id":42418557223066,"sku":"NNC1678X","price":1.09,"currency_code":"USD","in_stock":true},{"title":"Green","offer_id":42418557255834,"sku":"NNC1678X-2","price":1.09,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/IMA_XLP_BLK_f083f472-8242-4315-927e-2dcc2b7b6d8d.png?v=1780985984"},{"product_id":"250-mcm-aluminum-rhh-rhw-2-xlp-use-2-direct-burial","title":"250 MCM Aluminum XLP USE-2 RHH\/RHW-2 Direct Burial Building Wire","description":"\u003cp\u003e[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/AL_XLP.pdf?v=1724417087\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e250 MCM Aluminum XLP USE-2 RHH\/RHW-2 Direct Burial Building Wire\u003c\/h2\u003e\n\u003cp data-end=\"150\" data-start=\"61\"\u003e\u003cstrong data-end=\"148\" data-start=\"61\"\u003eAllowable Ampacity for 250 MCM ALUMINUM RHH\/RHW-2 XLP USE-2 DIRECT BURIAL: 215 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 data-end=\"174\" data-start=\"152\"\u003e\u003cstrong data-end=\"172\" data-start=\"157\"\u003eDescription\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-end=\"729\" data-start=\"175\"\u003eThis cable is a high-capacity power distribution cable with multiple ratings—RHH, RHW-2, XLP, and USE-2—designed for underground and raceway installations. The RHH rating ensures heat resistance in dry locations, while RHW-2 makes it water-resistant and suitable for 90°C operation in both wet and dry conditions. The XLP (cross-linked polyethylene) insulation enhances durability, abrasion resistance, and electrical performance. The USE-2 rating allows for direct burial and underground service entrance installations.\u003c\/p\u003e\n\u003cp data-end=\"1100\" data-start=\"731\"\u003eUSE-2 cables are commonly used for power distribution, service entrance below ground, and direct burial, as well as in raceways. This electrical cable is approved under the National Electrical Code (NEC), except for use in cable trays. It supports a voltage rating of 600V and operates at a maximum temperature of 90°C in wet and dry environments.\u003c\/p\u003e\n\u003ch3 data-end=\"1146\" data-start=\"1102\"\u003e\u003cstrong data-end=\"1144\" data-start=\"1106\"\u003eAmpacity Ratings (Per NEC 310.16):\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-end=\"1246\" data-start=\"1147\"\u003e\n\u003cli data-end=\"1188\" data-start=\"1147\"\u003e\n\u003cstrong data-end=\"1171\" data-start=\"1149\"\u003eIn Free Air (90°C)\u003c\/strong\u003e → \u003cstrong data-end=\"1186\" data-start=\"1174\"\u003e290 Amps\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1246\" data-start=\"1189\"\u003e\n\u003cstrong data-end=\"1229\" data-start=\"1191\"\u003eIn Direct Burial or Raceway (90°C)\u003c\/strong\u003e → \u003cstrong data-end=\"1244\" data-start=\"1232\"\u003e215 Amps\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"1296\" data-start=\"1248\"\u003e\u003cstrong data-end=\"1294\" data-start=\"1252\"\u003eCommon Applications for 250 MCM Cable:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-end=\"1834\" data-start=\"1297\"\u003e\n\u003cli data-end=\"1404\" data-start=\"1297\"\u003e\n\u003cstrong data-end=\"1355\" data-start=\"1299\"\u003ePrimary and secondary underground power distribution\u003c\/strong\u003e for large commercial and industrial buildings.\u003c\/li\u003e\n\u003cli data-end=\"1503\" data-start=\"1405\"\u003e\n\u003cstrong data-end=\"1434\" data-start=\"1407\"\u003eService entrance wiring\u003c\/strong\u003e for high-capacity single-phase and three-phase electrical systems.\u003c\/li\u003e\n\u003cli data-end=\"1610\" data-start=\"1504\"\u003e\n\u003cstrong data-end=\"1525\" data-start=\"1506\"\u003eFeeder circuits\u003c\/strong\u003e supplying power to large switchgear, distribution panels, and high-load equipment.\u003c\/li\u003e\n\u003cli data-end=\"1710\" data-start=\"1611\"\u003e\n\u003cstrong data-end=\"1644\" data-start=\"1613\"\u003eDirect burial installations\u003c\/strong\u003e for long-distance power transmission with minimal voltage drop.\u003c\/li\u003e\n\u003cli data-end=\"1834\" data-start=\"1711\"\u003e\n\u003cstrong data-end=\"1783\" data-start=\"1713\"\u003eUtility, infrastructure, and large-scale agricultural applications\u003c\/strong\u003e requiring high ampacity and moisture resistance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"2008\" data-start=\"1836\"\u003eThis \u003cstrong data-end=\"1867\" data-start=\"1841\"\u003e250 MCM aluminum cable\u003c\/strong\u003e is commonly used for \u003cstrong data-end=\"2005\" data-start=\"1889\"\u003eindustrial feeder circuits, large service entrances, and underground power distribution requiring up to 215 amps\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e250 MCM wire, \u003cspan\u003e250 MCM \u003c\/span\u003ealuminum rhh wire, \u003cspan\u003e250 MCM \u003c\/span\u003ealuminum rhw cable, \u003cspan\u003e250 MCM \u003c\/span\u003ealuminum bury cable, direct burial electrical cable, direct burial power cable, direct burial service entrance cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eUL 44\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eUL 854\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eNEMA WC 70\/ICEA S-95-658\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eRequirements of the National Electrical Code\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eASTM B800, B801, B836\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eSunlight resistant\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eOil Resistant PRI\/PRII\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eGas and Oil Res GRI\/GRII\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eRUS ACCEPTED\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConstruction\u003c\/h3\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eConductors:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eCompact bare 8000 series aluminum, with Class B stranding per ASTM. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eInsulation:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003eAbrasion, heat and moisture resistant cross-linked polyethylene insulation (XLP)\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eGauge\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e250\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eStranding\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 35\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eConductor Diameter Inches\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 0.520\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eInsulation Thickness Inches\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 0.110\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eO.D. Inches\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 0.740\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eNew Weight lb\/1000FT\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 1085 lbs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eAmpacity \u003c\/b\u003e\u003cb\u003eat 30°C\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 215 Amps\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ctable style=\"width: 436px; height: 333px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"width: 426px; height: 21px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 103px;\"\u003e\n\u003ctd style=\"width: 211.344px;\"\u003e\u003cstrong\u003eHouston item :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 208.656px;\"\u003e\n\u003cspan\u003e\u003cstrong\u003eBlack : \u003c\/strong\u003eHW003A25001\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eBlack : \u003c\/strong\u003e250-01XLPUSEBLACKAL\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"width: 211.344px; height: 35px;\"\u003e\u003cstrong\u003ePriority Wire \u0026amp; Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 208.656px; height: 35px;\"\u003e\n\u003cstrong\u003eBlack :\u003c\/strong\u003e 250-01XL-USE-2-ALUM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 54px;\"\u003e\n\u003ctd style=\"width: 211.344px;\"\u003e\u003cstrong\u003eSouthwire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 208.656px;\"\u003e\n\u003cstrong\u003eBlack :\u003c\/strong\u003e 27288001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Black","offer_id":42418845647002,"sku":"NNC1679X","price":2.29,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/Product2_7b7f18ab-e334-4bdf-bfc2-f67028acbe6d.png?v=1762458394"},{"product_id":"350-mcm-aluminum-xlp-use-2-rhh-rhw-2-direct-burial-building-wire","title":"350 MCM Aluminum XLP USE-2 RHH\/RHW-2 Direct Burial Building Wire","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/AL_XLP.pdf?v=1724417087\" width=\"\" height=\"\" type=\"application\/pdf\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e350 MCM Aluminum XLP USE-2 RHH\/RHW-2 Direct Burial Building Wire\u003c\/h2\u003e\n\u003cp data-start=\"61\" data-end=\"150\"\u003eAllowable Ampacity for 350 MCM Aluminum XLP USE-2 RHH\/RHW-2 Direct Burial Building Wire: 260 Amps\u003c\/p\u003e\n\u003ch3 data-start=\"152\" data-end=\"174\"\u003e\u003cstrong data-start=\"157\" data-end=\"172\"\u003eDescription\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"175\" data-end=\"729\"\u003eThis cable is a high-capacity power distribution cable with multiple ratings—RHH, RHW-2, XLP, and USE-2—designed for underground and raceway installations. The RHH rating ensures heat resistance in dry locations, while RHW-2 makes it water-resistant and suitable for 90°C operation in both wet and dry conditions. The XLP (cross-linked polyethylene) insulation enhances durability, abrasion resistance, and electrical performance. The USE-2 rating allows for direct burial and underground service entrance installations.\u003c\/p\u003e\n\u003cp data-start=\"731\" data-end=\"1100\"\u003eUSE-2 cables are commonly used for power distribution, service entrance below ground, and direct burial, as well as in raceways. This electrical cable is approved under the National Electrical Code (NEC), except for use in cable trays. It supports a voltage rating of 600V and operates at a maximum temperature of 90°C in wet and dry environments.\u003c\/p\u003e\n\u003ch3 data-start=\"1102\" data-end=\"1146\"\u003e\u003cstrong data-start=\"1106\" data-end=\"1144\"\u003eAmpacity Ratings (Per NEC 310.16):\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1147\" data-end=\"1246\"\u003e\n\u003cli data-start=\"1147\" data-end=\"1188\"\u003e\n\u003cstrong data-start=\"1149\" data-end=\"1171\"\u003eIn Free Air (90°C)\u003c\/strong\u003e → \u003cstrong data-start=\"1174\" data-end=\"1186\"\u003e350 Amps\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1189\" data-end=\"1246\"\u003e\n\u003cstrong data-start=\"1191\" data-end=\"1229\"\u003eIn Direct Burial or Raceway (90°C)\u003c\/strong\u003e → \u003cstrong data-start=\"1232\" data-end=\"1244\"\u003e260 Amps\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1248\" data-end=\"1296\"\u003e\u003cstrong data-start=\"1252\" data-end=\"1294\"\u003eCommon Applications for 350 MCM Cable:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1297\" data-end=\"1870\"\u003e\n\u003cli data-start=\"1297\" data-end=\"1429\"\u003e\n\u003cstrong data-start=\"1299\" data-end=\"1355\"\u003ePrimary and secondary underground power distribution\u003c\/strong\u003e for large commercial, industrial, and multi-unit residential buildings.\u003c\/li\u003e\n\u003cli data-start=\"1430\" data-end=\"1528\"\u003e\n\u003cstrong data-start=\"1432\" data-end=\"1459\"\u003eService entrance wiring\u003c\/strong\u003e for high-capacity single-phase and three-phase electrical systems.\u003c\/li\u003e\n\u003cli data-start=\"1529\" data-end=\"1646\"\u003e\n\u003cstrong data-start=\"1531\" data-end=\"1550\"\u003eFeeder circuits\u003c\/strong\u003e supplying power to large switchgear, distribution panels, and high-load industrial equipment.\u003c\/li\u003e\n\u003cli data-start=\"1647\" data-end=\"1746\"\u003e\n\u003cstrong data-start=\"1649\" data-end=\"1680\"\u003eDirect burial installations\u003c\/strong\u003e for long-distance power transmission with minimal voltage drop.\u003c\/li\u003e\n\u003cli data-start=\"1747\" data-end=\"1870\"\u003e\n\u003cstrong data-start=\"1749\" data-end=\"1819\"\u003eUtility, infrastructure, and large-scale agricultural applications\u003c\/strong\u003e requiring high ampacity and moisture resistance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1872\" data-end=\"2055\"\u003eThis \u003cstrong data-start=\"1877\" data-end=\"1903\"\u003e350 MCM aluminum cable\u003c\/strong\u003e is commonly used for \u003cstrong data-start=\"1925\" data-end=\"2052\"\u003elarge industrial feeder circuits, high-power service entrances, and underground power distribution requiring up to 260 amps\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e\u003cspan\u003e350 m\u003c\/span\u003ecm wire, \u003cspan\u003e350 \u003c\/span\u003emcm aluminum wire, \u003cspan\u003e350 \u003c\/span\u003emcm wire size, rhh wire, rhh cable, bury cable, direct burial electrical cable, direct burial mc cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eUL 44\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eUL 854\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eNEMA WC 70\/ICEA S-95-658\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eRequirements of the National Electrical Code\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eASTM B800, B801, B836\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eSunlight resistant\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eOil Resistant PRI\/PRII\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eGas and Oil Res GRI\/GRII\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eRUS ACCEPTED\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConstruction\u003c\/h3\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eConductors:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eCompact bare 8000 series aluminum, with Class B stranding per ASTM. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eInsulation:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003eAbrasion, heat and moisture resistant cross-linked polyethylene insulation (XLP)\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eGauge\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e350\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eStranding\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 35\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eConductor Diameter Inches\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 0.614\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eInsulation Thickness Inches\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 0.110\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eO.D. Inches\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 0.840\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eNew Weight lb\/1000FT\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 1454 lbs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eAmpacity \u003c\/b\u003e\u003cb\u003eat 30°C\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 260 Amps\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ctable style=\"width: 436px; height: 333px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"width: 426px; height: 21px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 103px;\"\u003e\n\u003ctd style=\"width: 211.344px;\"\u003e\u003cstrong\u003eHouston item :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 208.656px;\"\u003e\n\u003cspan\u003e\u003cstrong\u003eBlack : \u003c\/strong\u003eHW003A35001\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eBlack : \u003c\/strong\u003e350-01XLPUSEBLACKAL\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"width: 211.344px; height: 35px;\"\u003e\u003cstrong\u003ePriority Wire \u0026amp; Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 208.656px; height: 35px;\"\u003e\n\u003cstrong\u003eBlack :\u003c\/strong\u003e 350-01XL-USE-2-ALUM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 54px;\"\u003e\n\u003ctd style=\"width: 211.344px;\"\u003e\u003cstrong\u003eSouthwire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 208.656px;\"\u003e\n\u003cstrong\u003eBlack :\u003c\/strong\u003e 27290601\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Black","offer_id":63404116017521,"sku":"NNC1680X","price":2.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/IMA_XLP_BLK_f083f472-8242-4315-927e-2dcc2b7b6d8d.png?v=1780985984"},{"product_id":"400-mcm-aluminum-xlp-use-2-rhh-rhw-2-direct-burial-building-wire","title":"400 MCM Aluminum XLP USE-2 RHH\/RHW-2 Direct Burial Building Wire","description":"\u003cp\u003e[pdf] \u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/AL_XLP.pdf?v=1724417087\" width=\"\" height=\"\" type=\"application\/pdf\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e400 MCM Aluminum XLP USE-2 RHH\/RHW-2 Direct Burial Building Wire\u003c\/h2\u003e\n\u003cp data-start=\"61\" data-end=\"150\"\u003e\u003cstrong data-start=\"61\" data-end=\"148\"\u003eAllowable Ampacity for 400 MCM Aluminum XLP USE-2 RHH\/RHW-2 Direct Burial Building Wire: 290 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 data-start=\"152\" data-end=\"174\"\u003e\u003cstrong data-start=\"157\" data-end=\"172\"\u003eDescription\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"175\" data-end=\"729\"\u003eThis cable is a high-capacity power distribution cable with multiple ratings—RHH, RHW-2, XLP, and USE-2—designed for underground and raceway installations. The RHH rating ensures heat resistance in dry locations, while RHW-2 makes it water-resistant and suitable for 90°C operation in both wet and dry conditions. The XLP (cross-linked polyethylene) insulation enhances durability, abrasion resistance, and electrical performance. The USE-2 rating allows for direct burial and underground service entrance installations.\u003c\/p\u003e\n\u003cp data-start=\"731\" data-end=\"1100\"\u003eUSE-2 cables are commonly used for power distribution, service entrance below ground, and direct burial, as well as in raceways. This electrical cable is approved under the National Electrical Code (NEC), except for use in cable trays. It supports a voltage rating of 600V and operates at a maximum temperature of 90°C in wet and dry environments.\u003c\/p\u003e\n\u003ch3 data-start=\"1102\" data-end=\"1146\"\u003e\u003cstrong data-start=\"1106\" data-end=\"1144\"\u003eAmpacity Ratings (Per NEC 310.16):\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1147\" data-end=\"1246\"\u003e\n\u003cli data-start=\"1147\" data-end=\"1188\"\u003e\n\u003cstrong data-start=\"1149\" data-end=\"1171\"\u003eIn Free Air (90°C)\u003c\/strong\u003e → \u003cstrong data-start=\"1174\" data-end=\"1186\"\u003e380 Amps\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1189\" data-end=\"1246\"\u003e\n\u003cstrong data-start=\"1191\" data-end=\"1229\"\u003eIn Direct Burial or Raceway (90°C)\u003c\/strong\u003e → \u003cstrong data-start=\"1232\" data-end=\"1244\"\u003e290 Amps\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1248\" data-end=\"1296\"\u003e\u003cstrong data-start=\"1252\" data-end=\"1294\"\u003eCommon Applications for 400 MCM Cable:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1297\" data-end=\"1870\"\u003e\n\u003cli data-start=\"1297\" data-end=\"1429\"\u003e\n\u003cstrong data-start=\"1299\" data-end=\"1355\"\u003ePrimary and secondary underground power distribution\u003c\/strong\u003e for large commercial, industrial, and multi-unit residential buildings.\u003c\/li\u003e\n\u003cli data-start=\"1430\" data-end=\"1528\"\u003e\n\u003cstrong data-start=\"1432\" data-end=\"1459\"\u003eService entrance wiring\u003c\/strong\u003e for high-capacity single-phase and three-phase electrical systems.\u003c\/li\u003e\n\u003cli data-start=\"1529\" data-end=\"1646\"\u003e\n\u003cstrong data-start=\"1531\" data-end=\"1550\"\u003eFeeder circuits\u003c\/strong\u003e supplying power to large switchgear, distribution panels, and high-load industrial equipment.\u003c\/li\u003e\n\u003cli data-start=\"1647\" data-end=\"1746\"\u003e\n\u003cstrong data-start=\"1649\" data-end=\"1680\"\u003eDirect burial installations\u003c\/strong\u003e for long-distance power transmission with minimal voltage drop.\u003c\/li\u003e\n\u003cli data-start=\"1747\" data-end=\"1870\"\u003e\n\u003cstrong data-start=\"1749\" data-end=\"1819\"\u003eUtility, infrastructure, and large-scale agricultural applications\u003c\/strong\u003e requiring high ampacity and moisture resistance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1872\" data-end=\"2055\"\u003eThis \u003cstrong data-start=\"1877\" data-end=\"1903\"\u003e400 MCM aluminum cable\u003c\/strong\u003e is commonly used for \u003cstrong data-start=\"1925\" data-end=\"2052\"\u003elarge industrial feeder circuits, high-power service entrances, and underground power distribution requiring up to 290 amps\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e400 mcm wire, 400 mcm aluminum wire, 400 mcm wire size, rhh wire, rhh cable, bury cable, direct burial electrical cable, direct burial mc cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eUL 44\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eUL 854\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eNEMA WC 70\/ICEA S-95-658\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eRequirements of the National Electrical Code\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eASTM B800, B801, B836\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eSunlight resistant\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eOil Resistant PRI\/PRII\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eGas and Oil Res GRI\/GRII\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eRUS ACCEPTED\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConstruction\u003c\/h3\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eConductors:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eCompact bare 8000 series aluminum, with Class B stranding per ASTM. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eInsulation:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003eAbrasion, heat and moisture resistant cross-linked polyethylene insulation (XLP)\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eGauge\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e400\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eStranding\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 37\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eConductor Diameter Inches\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 0.657\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eInsulation Thickness Inches\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 0.110\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eO.D. Inches\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 0.790\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eNew Weight lb\/1000FT\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 1646 lbs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eAmpacity \u003c\/b\u003e\u003cb\u003eat 30°C:\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e 290 Amps\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable style=\"width: 436px; height: 333px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"width: 426px; height: 21px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 103px;\"\u003e\n\u003ctd style=\"width: 211.344px;\"\u003e\u003cstrong\u003eHouston item :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 208.656px;\"\u003e\u003cspan\u003e\u003cstrong\u003eBlack : \u003c\/strong\u003e400-01XLPUSEBLACKAL\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"width: 211.344px; height: 35px;\"\u003e\u003cstrong\u003ePriority Wire \u0026amp; Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 208.656px; height: 35px;\"\u003e\n\u003cstrong\u003eBlack :\u003c\/strong\u003e 400-01XL-USE-2-ALUM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 54px;\"\u003e\n\u003ctd style=\"width: 211.344px;\"\u003e\u003cstrong\u003eSouthwire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 208.656px;\"\u003e\n\u003cstrong\u003eBlack :\u003c\/strong\u003e 27291499\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Black","offer_id":63404116115825,"sku":"NNC1682X","price":4.14,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/IMA_XLP_BLK_f083f472-8242-4315-927e-2dcc2b7b6d8d.png?v=1780985984"},{"product_id":"500-mcm-aluminum-xlp-use-2-rhh-rhw-2-direct-burial-building-wire","title":"500 MCM Aluminum XLP USE-2 RHH\/RHW-2 Direct Burial Building Wire","description":"\u003cp\u003e[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/AL_XLP.pdf?v=1724417087\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e500 MCM Aluminum XLP USE-2 RHH\/RHW-2 Direct Burial Building Wire\u003c\/h2\u003e\n\u003cp data-start=\"61\" data-end=\"150\"\u003e\u003cstrong data-start=\"61\" data-end=\"148\"\u003eAllowable Ampacity for 500 MCM Aluminum XLP USE-2 RHH\/RHW-2 Direct Burial Building Wire: 330 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 data-start=\"152\" data-end=\"174\"\u003e\u003cstrong data-start=\"157\" data-end=\"172\"\u003eDescription\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"175\" data-end=\"729\"\u003eThis cable is a high-capacity power distribution cable with multiple ratings—RHH, RHW-2, XLP, and USE-2—designed for underground and raceway installations. The RHH rating ensures heat resistance in dry locations, while RHW-2 makes it water-resistant and suitable for 90°C operation in both wet and dry conditions. The XLP (cross-linked polyethylene) insulation enhances durability, abrasion resistance, and electrical performance. The USE-2 rating allows for direct burial and underground service entrance installations.\u003c\/p\u003e\n\u003cp data-start=\"731\" data-end=\"1100\"\u003eUSE-2 cables are commonly used for power distribution, service entrance below ground, and direct burial, as well as in raceways. This electrical cable is approved under the National Electrical Code (NEC), except for use in cable trays. It supports a voltage rating of 600V and operates at a maximum temperature of 90°C in wet and dry environments.\u003c\/p\u003e\n\u003ch3 data-start=\"1102\" data-end=\"1146\"\u003e\u003cstrong data-start=\"1106\" data-end=\"1144\"\u003eAmpacity Ratings (Per NEC 310.16):\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1147\" data-end=\"1246\"\u003e\n\u003cli data-start=\"1147\" data-end=\"1188\"\u003e\n\u003cstrong data-start=\"1149\" data-end=\"1171\"\u003eIn Free Air (90°C)\u003c\/strong\u003e → \u003cstrong data-start=\"1174\" data-end=\"1186\"\u003e430 Amps\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1189\" data-end=\"1246\"\u003e\n\u003cstrong data-start=\"1191\" data-end=\"1229\"\u003eIn Direct Burial or Raceway (90°C)\u003c\/strong\u003e → \u003cstrong data-start=\"1232\" data-end=\"1244\"\u003e330 Amps\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1248\" data-end=\"1296\"\u003e\u003cstrong data-start=\"1252\" data-end=\"1294\"\u003eCommon Applications for 500 MCM Cable:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1297\" data-end=\"1855\"\u003e\n\u003cli data-start=\"1297\" data-end=\"1429\"\u003e\n\u003cstrong data-start=\"1299\" data-end=\"1355\"\u003ePrimary and secondary underground power distribution\u003c\/strong\u003e for industrial facilities, large commercial buildings, and substations.\u003c\/li\u003e\n\u003cli data-start=\"1430\" data-end=\"1528\"\u003e\n\u003cstrong data-start=\"1432\" data-end=\"1459\"\u003eService entrance wiring\u003c\/strong\u003e for high-capacity single-phase and three-phase electrical systems.\u003c\/li\u003e\n\u003cli data-start=\"1529\" data-end=\"1640\"\u003e\n\u003cstrong data-start=\"1531\" data-end=\"1550\"\u003eFeeder circuits\u003c\/strong\u003e supplying power to high-load distribution panels, switchgear, and industrial equipment.\u003c\/li\u003e\n\u003cli data-start=\"1641\" data-end=\"1731\"\u003e\n\u003cstrong data-start=\"1643\" data-end=\"1674\"\u003eDirect burial installations\u003c\/strong\u003e for high-power transmission with minimal voltage drop.\u003c\/li\u003e\n\u003cli data-start=\"1732\" data-end=\"1855\"\u003e\n\u003cstrong data-start=\"1734\" data-end=\"1804\"\u003eUtility, infrastructure, and large-scale agricultural applications\u003c\/strong\u003e requiring high ampacity and moisture resistance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1857\" data-end=\"2034\"\u003eThis \u003cstrong data-start=\"1862\" data-end=\"1888\"\u003e500 MCM aluminum cable\u003c\/strong\u003e is commonly used for \u003cstrong data-start=\"1910\" data-end=\"2031\"\u003eindustrial feeder circuits, high-power service entrances, and underground power distribution requiring up to 330 amps\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e500 mcm wire, 500 mcm aluminum wire, 500 mcm wire size, rhh wire, rhh cable, bury cable, direct burial electrical cable, direct burial mc cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eUL 44\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eUL 854\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eNEMA WC 70\/ICEA S-95-658\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eRequirements of the National Electrical Code\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eASTM B800, B801, B836\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eSunlight resistant\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eOil Resistant PRI\/PRII\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eGas and Oil Res GRI\/GRII\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eRUS ACCEPTED\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConstruction\u003c\/h3\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eConductors:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eCompact bare 8000 series aluminum, with Class B stranding per ASTM. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eInsulation:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003eAbrasion, heat and moisture resistant cross-linked polyethylene insulation (XLP)\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eGauge\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e500\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eStranding\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 35\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eConductor Diameter Inches\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 0.736\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eInsulation Thickness Inches\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 0.110\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eO.D. Inches\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 0.960\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eNew Weight lb\/1000FT\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 1998 lbs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eAmpacity \u003c\/b\u003e\u003cb\u003eat 30°C: \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e330 Amps\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ctable style=\"width: 436px; height: 333px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 426px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 103px;\"\u003e\n\u003ctd style=\"width: 211.344px;\"\u003e\u003cstrong\u003eHouston item :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 208.656px;\"\u003e\u003cspan\u003e\u003cstrong\u003eBlack : \u003c\/strong\u003eHW003A50001\u003cbr\u003e\u003cstrong\u003eBlack :\u003c\/strong\u003e 500-01XLPUSEBLACKAL\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"width: 211.344px; height: 35px;\"\u003e\u003cstrong\u003ePriority Wire \u0026amp; Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 208.656px; height: 35px;\"\u003e\n\u003cstrong\u003eBlack :\u003c\/strong\u003e 500-01XL-USE-2-ALUM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 54px;\"\u003e\n\u003ctd style=\"width: 211.344px;\"\u003e\u003cstrong\u003eSouthwire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 208.656px;\"\u003e\n\u003cstrong\u003eBlack :\u003c\/strong\u003e 27292201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Black","offer_id":42418826870938,"sku":"NNC1683X","price":3.84,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/Product2_7ce5275e-84f9-476a-b7c7-7ff7534efc3e.png?v=1762458396"},{"product_id":"750-mcm-aluminum-xlp-use-2-rhh-rhw-2-direct-burial-building-wire","title":"750 MCM Aluminum XLP USE-2 RHH\/RHW-2 Direct Burial Building Wire","description":"\u003cp\u003e[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/AL_XLP.pdf?v=1724417087\"\u003e [\/pdf]\u003c\/embed\u003e\u003c\/p\u003e\n\u003ch2\u003e750 MCM Aluminum XLP USE-2 RHH\/RHW-2 Direct Burial Building Wire\u003c\/h2\u003e\n\u003cp data-end=\"150\" data-start=\"61\"\u003e\u003cstrong data-end=\"148\" data-start=\"61\"\u003eAllowable Ampacity for 750 MCM Aluminum XLP USE-2 RHH\/RHW-2 Direct Burial Building Wire: 480 Amps\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 data-end=\"174\" data-start=\"152\"\u003e\u003cstrong data-end=\"172\" data-start=\"157\"\u003eDescription\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-end=\"729\" data-start=\"175\"\u003eThis cable is a high-capacity power distribution cable with multiple ratings—RHH, RHW-2, XLP, and USE-2—designed for underground and raceway installations. The RHH rating ensures heat resistance in dry locations, while RHW-2 makes it water-resistant and suitable for 90°C operation in both wet and dry conditions. The XLP (cross-linked polyethylene) insulation enhances durability, abrasion resistance, and electrical performance. The USE-2 rating allows for direct burial and underground service entrance installations.\u003c\/p\u003e\n\u003cp data-end=\"1100\" data-start=\"731\"\u003eUSE-2 cables are commonly used for power distribution, service entrance below ground, and direct burial, as well as in raceways. This electrical cable is approved under the National Electrical Code (NEC), except for use in cable trays. It supports a voltage rating of 600V and operates at a maximum temperature of 90°C in wet and dry environments.\u003c\/p\u003e\n\u003ch3 data-end=\"1146\" data-start=\"1102\"\u003e\u003cstrong data-end=\"1144\" data-start=\"1106\"\u003eAmpacity Ratings (Per NEC 310.16):\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-end=\"1246\" data-start=\"1147\"\u003e\n\u003cli data-end=\"1188\" data-start=\"1147\"\u003e\n\u003cstrong data-end=\"1171\" data-start=\"1149\"\u003eIn Free Air (90°C)\u003c\/strong\u003e → \u003cstrong data-end=\"1186\" data-start=\"1174\"\u003e555 Amps\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1246\" data-start=\"1189\"\u003e\n\u003cstrong data-end=\"1229\" data-start=\"1191\"\u003eIn Direct Burial or Raceway (90°C)\u003c\/strong\u003e → \u003cstrong data-end=\"1244\" data-start=\"1232\"\u003e480 Amps\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"1296\" data-start=\"1248\"\u003e\u003cstrong data-end=\"1294\" data-start=\"1252\"\u003eCommon Applications for 750 MCM Cable:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-end=\"1877\" data-start=\"1297\"\u003e\n\u003cli data-end=\"1432\" data-start=\"1297\"\u003e\n\u003cstrong data-end=\"1355\" data-start=\"1299\"\u003ePrimary and secondary underground power distribution\u003c\/strong\u003e for large-scale industrial plants, substations, and commercial facilities.\u003c\/li\u003e\n\u003cli data-end=\"1531\" data-start=\"1433\"\u003e\n\u003cstrong data-end=\"1462\" data-start=\"1435\"\u003eService entrance wiring\u003c\/strong\u003e for high-capacity single-phase and three-phase electrical systems.\u003c\/li\u003e\n\u003cli data-end=\"1649\" data-start=\"1532\"\u003e\n\u003cstrong data-end=\"1553\" data-start=\"1534\"\u003eFeeder circuits\u003c\/strong\u003e supplying power to high-load switchgear, distribution panels, and large industrial equipment.\u003c\/li\u003e\n\u003cli data-end=\"1754\" data-start=\"1650\"\u003e\n\u003cstrong data-end=\"1683\" data-start=\"1652\"\u003eDirect burial installations\u003c\/strong\u003e for long-distance high-power transmission with minimal voltage drop.\u003c\/li\u003e\n\u003cli data-end=\"1877\" data-start=\"1755\"\u003e\n\u003cstrong data-end=\"1826\" data-start=\"1757\"\u003eUtility, infrastructure, and heavy-duty agricultural applications\u003c\/strong\u003e requiring high ampacity and moisture resistance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"2053\" data-start=\"1879\"\u003eThis \u003cstrong data-end=\"1910\" data-start=\"1884\"\u003e750 MCM aluminum cable\u003c\/strong\u003e is commonly used for \u003cstrong data-end=\"2050\" data-start=\"1932\"\u003elarge-scale power distribution, industrial feeder circuits, and underground installations requiring up to 480 amps\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eAlso Known As:\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e750 mcm wire, 750 mcm aluminum wire, 750 mcm wire size, rhh wire, rhh cable, bury cable, direct burial electrical cable, direct burial mc cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eStandards:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eUL 44\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eUL 854\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eNEMA WC 70\/ICEA S-95-658\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eRequirements of the National Electrical Code\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eASTM B800, B801, B836\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eSunlight resistant\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eOil Resistant PRI\/PRII\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eGas and Oil Res GRI\/GRII\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003eRUS ACCEPTED\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConstruction\u003c\/h3\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eConductors:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eCompact bare 8000 series aluminum, with Class B stranding per ASTM. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-weight: 400;\"\u003eInsulation:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003eAbrasion, heat and moisture resistant cross-linked polyethylene insulation (XLP)\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eGauge\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e750\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eStranding\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 58\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eConductor Diameter Inches\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 0.909\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eInsulation Thickness Inches\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 0.110\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eO.D. Inches\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 1.131\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eNew Weight lb\/1000FT\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 881 lbs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cp\u003e\u003cb\u003eAmpacity \u003c\/b\u003e\u003cb\u003eat 30°C\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 480 Amps\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ctable style=\"width: 436px; height: 333px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 426px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 103px;\"\u003e\n\u003ctd style=\"width: 211.344px;\"\u003e\u003cstrong\u003eHouston item :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 208.656px;\"\u003e\u003cspan\u003e\u003cstrong\u003eBlack : \u003c\/strong\u003eHW003A75001\u003cbr\u003e\u003cstrong\u003eBlack :\u003c\/strong\u003e 750-01XLPUSEBLACKAL\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"width: 211.344px; height: 35px;\"\u003e\u003cstrong\u003ePriority Wire \u0026amp; Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 208.656px; height: 35px;\"\u003e\n\u003cstrong\u003eBlack :\u003c\/strong\u003e 750-01XL-USE-2-ALUM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 54px;\"\u003e\n\u003ctd style=\"width: 211.344px;\"\u003e\u003cstrong\u003eSouthwire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 208.656px;\"\u003e\n\u003cstrong\u003eBlack :\u003c\/strong\u003e 27295501\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nassau National Cable","offers":[{"title":"Black","offer_id":42418816778394,"sku":"NNC4204X","price":5.79,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/Product2_251f007a-69b2-4d7b-bf6c-ed10ecff6de5.png?v=1762459244"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/collections\/Aluminum_RHH-RHW-2.jpg?v=1561961438","url":"https:\/\/nassaunationalcable.com\/collections\/aluminum-xlp-use-2-rhh-rhw-2-direct-burial-building-wire.oembed","provider":"NassauNationalCable","version":"1.0","type":"link"}