{"title":"Airport Lighting Cable 600V\/5kV","description":null,"products":[{"product_id":"specialty-lighting-cable-5kv","title":"Specialty Lighting Cable 5kv","description":"[pdf] \u003cembed type=\"application\/pdf\" height=\"\" width=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/files\/SPECIALTY_LIGHTING_CABLE_5KV.pdf?v=1723280570\"\u003e [\/pdf]\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eAirport Lighting Cables are used in runway and taxiway airport lighting systems, airport lighting circuits, control circuits, runways, taxiways, navigational aids, obstruction lighting (such as LED, Xenon, and Incandescent light fixtures), and miscellaneous conduit, duct, aerial, and direct burial applications. Airport runway lighting cable is built for usage in between the constant current source and the isolating transformers in the series lighting circuits. The cable is rugged, has excellent abrasion and jam resistance, and is not affected by de-icing fluid chemicals. Airport Cable is rated at 5000 volts.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eAirfield Lighting Cable, Airfield Ground Lighting Cable, Airport Cable, Airfield Cable, L284 type C cable, Runway Lighting Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eICEA S-66-524\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eFAA-L-824\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eRoHS\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eASTM B 8\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003ci\u003e\u003cspan style=\"font-weight: 400;\"\u003eConductor:\u003c\/span\u003e\u003c\/i\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e Fully annealed stranded bare copper with a class B stranding per ASTM B 8.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003ci\u003e\u003cspan style=\"font-weight: 400;\"\u003eInsulation:\u003c\/span\u003e\u003c\/i\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eBlack Cross-Linked Polyethylene (XLPE) over the semi-conductive stress control layer.\u003c\/span\u003e\u003c\/p\u003e\n[\/short]\n\u003ctable class=\"categoryLD_Tble\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"categoryLD_Col01\"\u003e\n\u003cstrong\u003eCONDUCTORS\u003c\/strong\u003e:\u003c\/td\u003e\n\u003ctd class=\"categoryLD_Col02\"\u003e\n\u003cul class=\"categoryLD_ul01\"\u003e\n\u003cli\u003e12 AWG – 4 AWG fully annealed stranded bare copper\u003c\/li\u003e\n\u003cli\u003eClass B stranding per ASTM B 8\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"categoryLD_Col01\"\u003e\u003cstrong\u003eINSULATION:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"categoryLD_Col02\"\u003e\n\u003cul class=\"categoryLD_ul01\"\u003e\n\u003cli\u003eBlack Cross-Linked Polyethylene (XLPE) over\u003cbr\u003esemi-conductive stress control layer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"categoryLD_Col01\"\u003e\n\u003cstrong\u003eFEATURES\u003c\/strong\u003e:\u003c\/td\u003e\n\u003ctd class=\"categoryLD_Col02\"\u003e\n\u003cul class=\"categoryLD_ul01\"\u003e\n\u003cli\u003eAvailable in 600 or 5000 volt constructions\u003c\/li\u003e\n\u003cli\u003eDirect Burial Approved\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"categoryLD_Col01\"\u003e\n\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e:\u003c\/td\u003e\n\u003ctd class=\"categoryLD_Col02\"\u003e\n\u003cul class=\"categoryLD_ul01\"\u003e\n\u003cli\u003eAirport lighting systems\u003c\/li\u003e\n\u003cli\u003eAirport control equipment\u003c\/li\u003e\n\u003cli\u003eOther conduit, duct, aerial, and direct burial applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"categoryLD_Col01\"\u003e\u003cstrong\u003eINDUSTRY APPROVALS:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"categoryLD_Col02\"\u003e\n\u003cul class=\"categoryLD_ul01\"\u003e\n\u003cli\u003eICEA S-66-524\u003c\/li\u003e\n\u003cli\u003eFAA-L-824\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27485356261476,"sku":"NNC3089X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/67.png?v=1759804654"},{"product_id":"specialty-lighting-cable-600v","title":"Specialty Lighting Cable 600V","description":"\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eAIRPORT LIGHTING CABLE 600V\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eAirport Lighting Cables are used in runway and taxiway airport lighting systems, airport lighting circuits, control circuits, runways, taxiways, navigational aids, obstruction lighting (such as LED, Xenon, and Incandescent light fixtures), and miscellaneous conduit, duct, aerial, and direct burial applications. Airport runway lighting cable is built for usage in between the constant current source and the isolating transformers in the series lighting circuits. The cable is rugged, has excellent abrasion and jam resistance, and is not affected by de-icing fluid chemicals. Airport Cable is rated at 600 volts.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e FAA-L-824 Airfield Lighting Cable, FAA-L-824 Airfield Ground Lighting Cable, FAA-L-824 Airport Cable,  FAA-L-824 Airfield Cable, FAA-L-824 L284 type C cable, FAA-L-824 Runway Lighting Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eICEA S-66-524\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eFAA-L-824\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eRoHS\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eASTM B 8\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003ci\u003e\u003cspan style=\"font-weight: 400;\"\u003eConductor:\u003c\/span\u003e\u003c\/i\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e Fully annealed stranded bare copper with a class B stranding per ASTM B 8.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003ci\u003e\u003cspan style=\"font-weight: 400;\"\u003eInsulation:\u003c\/span\u003e\u003c\/i\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eBlack Cross-Linked Polyethylene (XLPE) over the semi-conductive stress control layer.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n[\/short]\n\u003ctable class=\"categoryLD_Tble\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"categoryLD_Col01\"\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"categoryLD_Col02\"\u003e\n\u003cul class=\"categoryLD_ul01\"\u003e\n\u003cli\u003e12 AWG – 4 AWG fully annealed stranded bare copper\u003c\/li\u003e\n\u003cli\u003eClass B stranding per ASTM B 8\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"categoryLD_Col01\"\u003e\u003cstrong\u003eINSULATION:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"categoryLD_Col02\"\u003e\n\u003cul class=\"categoryLD_ul01\"\u003e\n\u003cli\u003eBlack Cross-Linked Polyethylene (XLPE) over\u003cbr\u003esemi-conductive stress control layer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"categoryLD_Col01\"\u003e\u003cstrong\u003eFEATURES:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"categoryLD_Col02\"\u003e\n\u003cul class=\"categoryLD_ul01\"\u003e\n\u003cli\u003eAvailable in 600 or 5000 volt constructions\u003c\/li\u003e\n\u003cli\u003eDirect Burial Approved\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"categoryLD_Col01\"\u003e\n\u003cstrong\u003eAPPLICATIONS\u003c\/strong\u003e:\u003c\/td\u003e\n\u003ctd class=\"categoryLD_Col02\"\u003e\n\u003cul class=\"categoryLD_ul01\"\u003e\n\u003cli\u003eAirport lighting systems\u003c\/li\u003e\n\u003cli\u003eAirport control equipment\u003c\/li\u003e\n\u003cli\u003eOther conduit, duct, aerial, and direct burial applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"categoryLD_Col01\"\u003e\n\u003cstrong\u003eOPTIONS\u003c\/strong\u003e:\u003c\/td\u003e\n\u003ctd class=\"categoryLD_Col02\"\u003e\n\u003cul class=\"categoryLD_ul01\"\u003e\n\u003cli\u003eTinned copper, shielding and colors available\u003cbr\u003eupon request\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"categoryLD_Col01\"\u003e\u003cstrong\u003eINDUSTRY APPROVALS:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"categoryLD_Col02\"\u003e\n\u003cul class=\"categoryLD_ul01\"\u003e\n\u003cli\u003eICEA S-66-524\u003c\/li\u003e\n\u003cli\u003eFAA-L-824\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e\u003cgdiv\u003e\u003c\/gdiv\u003e","brand":"Nassau National Cable","offers":[{"title":"Default Title","offer_id":27945812033636,"sku":"NNC33391X","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0213\/7895\/7412\/products\/68.png?v=1759810068"}],"url":"https:\/\/nassaunationalcable.com\/collections\/airport-lighting-cable-600v-5kv.oembed","provider":"NassauNationalCable","version":"1.0","type":"link"}